WorldWideScience

Sample records for capture therapy nct

  1. Recent advances in neutron capture therapy (NCT)

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.

    1985-01-01

    The application of the /sup 10/B(n,..cap alpha..)/sup 7/Li reaction to cancer radiotherapy (Neutron Capture therapy, or NCT) has intrigued investigators since the discovery of the neutron. This paper briefly summarizes data describing recently developed boronated compounds with evident tumor specificity and extended biological half-lives. The implication of these compounds to NCT is evaluated in terms of Therapeutic Gain (TG). The optimization of NCT using band-pass filtered beams is described, again in terms of TG, and irradiation times with these less intense beams are estimated. 24 refs., 3 figs., 3 tabs.

  2. New compounds for neutron capture therapy (NCT) and their significance

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.; Bond, V.P.

    1982-01-01

    Clearly the most effective tumor therapy would be obtained by the selective targeting of cytotoxic agents to tumor cells. Although many biomolecules are known to be taken up in tumors, the targeting of cytotoxic agents to tumors is limited by the fact that other essential cell pools compete with equal or even greater effectiveness. The approach of delivering stable non-toxic isotopes to tumor, with activation by means of an external radiation beam, is advantageous for two reasons: (1) it obviates problems associated with high uptake of isotopes in normal tissues, as these cell pools can be excluded from the radiation field, and (2) the general tumor area can be included in the activating beam field; thus, the possibility exists that all microscopic tumor extensions can be irradiated. As long as range of reaction products is short, dose will be restricted to the tumor, with a resultant high therapeutic ratio. This method can be accomplished with either photon activation therapy (PAT) or Neutron Capture Therapy (NCT), the latter will be emphasized here. The range of the high LET, low OER particles from the /sup 10/B(n,..cap alpha..)/sup 7/Li reaction is approx. 10 ..mu..m, or one cell diameter; hence this reaction is optimal for cell killing. A number of biomolecules have been investigated as possible vehicles for transport of boron to tumors, including phenothiazines, thiouracils, porphyrins, nucleosides, and amino acids. Biodistributions of these compounds show selective concentration in tumor adequate for therapy. The biological halflives are in the order of days, allowing the possibility of fractionated or protracted irradiations. The radiobiological and physical implication of these parameters on NCT are discussed. The possibility of using an approximately-monoenergetic, scandium-filtered beam of about 2 keV, to reduce the dose from background radiations by about 85%, is also discussed. (ERB)

  3. Dosimetric implications of new compounds for neutron capture therapy (NCT)

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.

    1982-01-01

    Systemic application of radiolabeled or cytotoxic agents should allow targeting of primary and metastatic neoplasms on a cellular level. In fact, drug uptake in non-target cell pools often exceeds toxic levels before sufficient amounts are delivered to tumor. In addition, at the large concentration of molecules necessary for therapy, effects of saturation are often found. Application of NCT can circumvent problems associated with high uptake in competing non-target cell pools, as the /sup 10/B(n,..cap alpha..)/sup 7/Li reaction is activated only within the radiation field. A comparison with other modes of particle therapy indicated that NCT provides significant advantages. It is however, difficult to obtain vehicles for boron transport which demonstrate both the tumor specificity and concentration requisite for NCT. A number of biomolecules have been investigated which show both the necessary concentration and specificity. These include chlorpromazine, thiouracil, porphyrins, amino acids, and nucleosides. However, these analogs have yet to be made available for NCT. Dosimetric implications of binding sites are considered, as well as alternate neutron sources. (ERB)

  4. Final Report: 8th International Symposium on Neutron Capture Therapy (NCT) for Cancer, May 15, 1998 - May 15, 1999

    International Nuclear Information System (INIS)

    The 8th International Symposium on Neutron Capture Therapy for Cancer (8th ISNCTC) was held in La Jolla, CA on Sept. 13-18, 1998. This biennial meeting of the International Society for Neutron Capture Therapy (ISNCT) was hosted by Society President M.F. Hawthorne (UCLA Dept. of Chemistry and Biochemistry). The Symposium brought together scientists (300 registrants from 21 countries) from diverse fields to report the latest developments in NCT. Topics of the 275 papers presented (30 plenary lectures, 81 oral presentations, and 164 posters) included the physics of neutron sources, chemistry of tumor-targeting agents, dosimetry, radiobiological studies, and clinical applications

  5. Neutron capture therapy (NCT) and in-hospital neutron irradiator (IHNI) a new technology on binary targeting radiation therapy of cancer

    International Nuclear Information System (INIS)

    BNCT is finally becoming 'a new option against cancer'. The difficulties for its development progress of that firstly is to improve the performance of boron compounds,secondly, it is the requirements of quantification and accuracy upon radiation dosimetry evaluation in clinical trials. Furthermore, that is long anticipation on hospital base neutron sources. It includes dedicated new NCT reactor, accelerator based neutron sources, and isotope source facilities. In addition to reactors, so far, the technology of other types of sources for clinical trials is not yet completely proven. The In-Hospital Neutron Irradiator specially designed for NCT, based on the MNSR successfully developed by China, can be installed inside or near the hospital and operated directly by doctors. The Irradiator has two neutron beams for respective treatment of the shallow and deep tumors. It is expected to initiate operation in the end of this year. It would provide a safe, low cost, and effective treatment tool for the NCT routine application in near future. (authors)

  6. Neutron capture therapy

    International Nuclear Information System (INIS)

    The overall state of the art related with neutron capture therapy(NCT) is surveyed. Since the field related with NCT is very wide, it is not intended to survey all related subjects in depth. The primary objective of this report is to help those working for the installation of a NCT facility and a PGNAA(prompt gamma ray neutron activation analysis) system for the boron analysis understand overall NCT at Hanaro. Therefore, while the parts of reactor neutron source and PGNAA are dealt in detail, other parts are limited to the level necessary to understand related fields. For example, the subject of chemical compound which requires intensive knowledge on chemistry, is not dealt as a separated item. However, the requirement of a compound for NCT, currently available compounds, their characteristics, etc. could be understood through this report. Although the subject of cancer treated by NCT is out of the capability of the author, it is dealt focussing its characteristics related with the success of NCT. Each detailed subject is expected to be dealt more detail by specialists in future. This report would be helpful for the researchers working for the NCT to understand related fields. (author). 128 refs., 3 tabs., 12 figs

  7. Neutron capture therapy. Principles and applications

    International Nuclear Information System (INIS)

    State of the art report on neutron capture therapy. Summarizes the progress made in recent decades. Multidisciplinary approach. Written by the most experienced specialists Neutron capture therapy (NCT) is based on the ability of the non-radioactive isotope boron-10 to capture thermal neutrons with very high probability and immediately to release heavy particles with a path length of one cell diameter. This in principle allows for tumor cell-selective high-LET particle radiotherapy. NCT is exciting scientifically but challenging clinically, and a key factor in success is close collaboration among very different disciplines. This book provides a comprehensive summary of the progress made in NCT in recent years. Individual sections cover all important aspects, including neutron sources, boron chemistry, drugs for NCT, dosimetry, and radiation biology. The use of NCT in a variety of malignancies and also some non-malignant diseases is extensively discussed. NCT is clearly shown to be a promising modality at the threshold of wider clinical application. All of the chapters are written by experienced specialists in language that will be readily understood by all participating disciplines.

  8. Workshop on neutron capture therapy

    International Nuclear Information System (INIS)

    Potentially optimal conditions for Neutron Capture Therapy (NCT) may soon be in hand due to the anticipated development of band-pass filtered beams relatively free of fast neutron contaminations, and of broadly applicable biomolecules for boron transport such as porphyrins and monoclonal antibodies. Consequently, a number of groups in the US are now devoting their efforts to exploring NCT for clinical application. The purpose of this Workshop was to bring these groups together to exchange views on significant problems of mutual interest, and to assure a unified and effective approach to the solutions. Several areas of preclinical investigation were deemed to be necessary before it would be possible to initiate clinical studies. As neither the monomer nor the dimer of sulfhydryl boron hydride is unequivocally preferable at this time, studies on both compounds should be continued until one is proven superior

  9. Workshop on neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.; Bond, V.P. (eds.)

    1986-01-01

    Potentially optimal conditions for Neutron Capture Therapy (NCT) may soon be in hand due to the anticipated development of band-pass filtered beams relatively free of fast neutron contaminations, and of broadly applicable biomolecules for boron transport such as porphyrins and monoclonal antibodies. Consequently, a number of groups in the US are now devoting their efforts to exploring NCT for clinical application. The purpose of this Workshop was to bring these groups together to exchange views on significant problems of mutual interest, and to assure a unified and effective approach to the solutions. Several areas of preclinical investigation were deemed to be necessary before it would be possible to initiate clinical studies. As neither the monomer nor the dimer of sulfhydryl boron hydride is unequivocally preferable at this time, studies on both compounds should be continued until one is proven superior.

  10. Neutron capture therapy at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Application of the 10B(n,α)7Li reaction to cancer radiotherapy (Neutron Capture therapy, or NCT) has intrigued investigators since shortly after the discovery of the neutron. This paper summarizes data describing recently developed boronated compounds designed to serve as vehicles for boron transport to tumor. Whole-body (mouse) Neutron Capture Radiograms (NCR) of some of the most promising compounds are presented; these graphically demonstrate selective uptake in tumor, at times varying from hours to days post administration. Comparison is made to the ubiquitous distribution of inorganic boron compounds used in the first clinical trials of NCT. Since some compounds are now available that allow physiological targeting of boron to tumor at concentrations adequate for therapy, the NCR technique can be used to evaluate important questions concerning the microdistribution of boron within the tumor. The implication of these compounds to NCT is evaluated in terms of Therapeutic Gain (TG). The optimization of NCT by using band-pass filtered neutron beams is described, again in terms of TG, and irradiation times with these less intense beams are estimated. 35 references, 12 figures, 4 tables

  11. Current status of neutron capture therapy

    International Nuclear Information System (INIS)

    There are about 6000 new glioblastoma multiform brain tumours diagnosed each year in the United States of America alone. This cancer is usually fatal within six months of diagnosis even with current standard treatments. Research on boron neutron capture therapy (BNCT) has been considered as a method of potentially curing such cancers. There is a great interest at under-utilised research reactors institutions to identify new medical utilization, attractive to the general public. Neutron capture therapy is a true multidisciplinary topic with a large variety of individuals involved. This publication attempts to provide current information for all those thinking about being involved with NCT, based on the knowledge and experience of those who have pioneered the treatment. It covers the whole range of NCT from designing reactor conversions or new facilities, through to clinical trials and their effectiveness. However, since most work has been done with boron capture therapy for brain tumours using modified thermal research reactors, this tends to be the focus of the report. One of the factors which need to be addressed at the beginning is the timing of the further development of NCT facilities. It should be emphasised that all current work is still at the research stage. Many of those now involved believe that there is little need for many more research facilities until such time as the treatment shows more promising results. For this and other reasons discussed in the report, very serious consideration should be given by research reactor owners and operators before spending large sums of money converting their facilities for NCT

  12. Development of inverse-planning system for neutron capture therapy

    International Nuclear Information System (INIS)

    To lead proper irradiation condition effectively, Japan Atomic Energy Agency (JAEA) is developing an inverse-planning system for neutron capture therapy (NCT-IPS) based on the JAEA computational dosimetry system (JCDS) for BNCT. The leading methodology of an optimum condition in the NCT-IPS has been applied spatial channel theory with adjoint flux solution of Botzman transport. By analyzing the results obtained from the adjoint flux calculations according to the theory, optimum incident point of the beam against the patient can be found, and neutron spectrum of the beam which can generate ideal distribution of neutron flux around tumor region can be determined. The conceptual design of the NCT-IPS was investigated, and prototype of NCT-IPS with JCDS is being developed. (author)

  13. Iodine neutron capture therapy

    Science.gov (United States)

    Ahmed, Kazi Fariduddin

    A new technique, Iodine Neutron Capture Therapy (INCT) is proposed to treat hyperthyroidism in people. Present thyroid therapies, surgical removal and 131I treatment, result in hypothyroidism and, for 131I, involve protracted treatment times and excessive whole-body radiation doses. The new technique involves using a low energy neutron beam to convert a fraction of the natural iodine stored in the thyroid to radioactive 128I, which has a 24-minute half-life and decays by emitting 2.12-MeV beta particles. The beta particles are absorbed in and damage some thyroid tissue cells and consequently reduce the production and release of thyroid hormones to the blood stream. Treatment times and whole-body radiation doses are thus reduced substantially. This dissertation addresses the first of the several steps needed to obtain medical profession acceptance and regulatory approval to implement this therapy. As with other such programs, initial feasibility is established by performing experiments on suitable small mammals. Laboratory rats were used and their thyroids were exposed to the beta particles coming from small encapsulated amounts of 128I. Masses of 89.0 mg reagent-grade elemental iodine crystals have been activated in the ISU AGN-201 reactor to provide 0.033 mBq of 128I. This activity delivers 0.2 Gy to the thyroid gland of 300-g male rats having fresh thyroid tissue masses of ˜20 mg. Larger iodine masses are used to provide greater doses. The activated iodine is encapsulated to form a thin (0.16 cm 2/mg) patch that is then applied directly to the surgically exposed thyroid of an anesthetized rat. Direct neutron irradiation of a rat's thyroid was not possible due to its small size. Direct in-vivo exposure of the thyroid of the rat to the emitted radiation from 128I is allowed to continue for 2.5 hours (6 half-lives). Pre- and post-exposure blood samples are taken to quantify thyroid hormone levels. The serum T4 concentration is measured by radioimmunoassay at

  14. A standardized method for beam design in neutron capture therapy

    International Nuclear Information System (INIS)

    A desirable end point for a given beam design for Neutron Capture Therapy (NCT) should be quantitative description of tumour control probability and normal tissue damage. Achieving this goal will ultimately rely on data from NCT human clinical trials. Traditional descriptions of beam designs have used a variety of assessment methods to quantify proposed or installed beam designs. These methods include measurement and calculation of open-quotes free fieldclose quotes parameters, such as neutron and gamma flux intensities and energy spectra, and figures-of-merit in tissue equivalent phantoms. The authors propose here a standardized method for beam design in NCT. This method would allow all proposed and existing NCT beam facilities to be compared equally. The traditional approach to determining a quantitative description of tumour control probability and normal tissue damage in NCT research may be described by the following path: Beam design → dosimetry → macroscopic effects → microscopic effects. Methods exist that allow neutron and gamma fluxes and energy dependence to be calculated and measured to good accuracy. By using this information and intermediate dosimetric quantities such as kerma factors for neutrons and gammas, macroscopic effect (absorbed dose) in geometries of tissue or tissue-equivalent materials can be calculated. After this stage, for NCT the data begins to become more sparse and in some areas ambiguous. Uncertainties in the Relative Biological Effectiveness (RBE) of some NCT dose components means that beam designs based on assumptions considered valid a few years ago may have to be reassessed. A standard method is therefore useful for comparing different NCT facilities

  15. Boron thermal/epithermal neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.

    1982-01-01

    The development of various particle beams for radiotherapy represents an attempt to improve dose distribution, and to provide high LET radiations which are less sensitive to ambient physical and radiobiological factors such as oxygen tension, cell cycle, and dose rate. In general, a compromise is necessary as effective RBE is reduced in order to spread the dose distribution over the anticipated tumor volume. The approach of delivering stable non-toxic isotopes to tumor, and then activating these atoms subsequently via an external radiation beam has mator advantages; problems associated with high uptake of these isotopes in competing cell pools are obviated, and the general tumor volume can be included in the treatment field of the activating beam. As long as the normal tissues supporting tumor show a low uptake of the isotope to be activated, and as long as the range of the reaction products is short, dose will be restricted to tumor, with a consequent high therapeutic ratio. Neutron Capture Therapy (NCT) is generally carried out by activating boron-10 with low energy neutrons. The range of the high LET, low OER particles from the /sup 10/B(n, ..cap alpha..)/sup 7/Li reaction is approx. 10..mu.., or one cell diameter, a situation that is optimal for cell killing. Significant advantages may be gained by using the NCT procedure in conjunction with improved tissue penetration provided with epithermal or filtered beams, and new compounds showing physiological binding to tumor.

  16. Insights into the use of gadolinium and gadolinium/boron-based agents in imaging-guided neutron capture therapy applications.

    Science.gov (United States)

    Deagostino, Annamaria; Protti, Nicoletta; Alberti, Diego; Boggio, Paolo; Bortolussi, Silva; Altieri, Saverio; Crich, Simonetta Geninatti

    2016-05-01

    Gadolinium neutron capture therapy (Gd-NCT) is currently under development as an alternative approach for cancer therapy. All of the clinical experience to date with NCT is done with (10)B, known as boron neutron capture therapy (BNCT), a binary treatment combining neutron irradiation with the delivery of boron-containing compounds to tumors. Currently, the use of Gd for NCT has been getting more attention because of its highest neutron cross-section. Although Gd-NCT was first proposed many years ago, its development has suffered due to lack of appropriate tumor-selective Gd agents. This review aims to highlight the recent advances for the design, synthesis and biological testing of new Gd- and B-Gd-containing compounds with the task of finding the best systems able to improve the NCT clinical outcome. PMID:27195428

  17. Carborane compounds for neutron capture therapy of malignant melanoma

    International Nuclear Information System (INIS)

    The possibility of using thiouracil as a vehicle for stable nuclei such as 10B for neutron capture therapy (NCT) of melanoma was first discussed by Fairchild and co-workers in 1982. The author's research has been directed towards the design and synthesis of a number of o-carboranyl-thiouracils, the ten boron atoms of the carborane cage having a clear advantage for NCT. The first step was the preparation, previously reported, of thiouracils bearing an alkyl group continuing a triple bond for later elaboration to a carborane. The present paper describes the continuation of this work with the preparation of the carboranes of this series and its extension to the synthesis of a thiouracil in which a carboranylalkyl group is attached to the nitrogen in the 3-position

  18. Neutron capture therapy for melanoma

    International Nuclear Information System (INIS)

    The development of boron-containing compounds which localize selectively in tumor may require a tumor-by-tumor type of approach that exploits any metabolic pathways unique to the particular type of tumor. Melanin-producing melanomas actively transport and metabolize aromatic amino acids for use as precursors in the synthesis of the pigment melanin. It has been shown that the boron-containing amino acid analog p-borono-phenylalanine (BPA) is selectively accumulated in melanoma tissue, producing boron concentrations in tumor that are within the range estimated to be necessary for successful boron neutron capture therapy (BNCT). We report here the results of therapy experiments carried out at the Brookhaven Medical Research Reactor (BMRR). 21 refs., 5 figs., 3 tabs

  19. Boron neutron capture therapy (BNCT) using fast neutrons: Effects in two human tumor cell lines

    International Nuclear Information System (INIS)

    The results demonstrate that the effect of fast neutrons on cell survival in cell culture can be enhanced by boron neutron capture reaction. Even with lower enhancement ratios, the concept of NCT assisted fast neutron therapy may successfully be applied for tumor treatment with the Essen cyclotron. (orig.)

  20. Resource-oriented music therapy for psychiatric patients with low therapy motivation: Protocol for a randomised controlled trial [NCT00137189

    Directory of Open Access Journals (Sweden)

    Aarre Trond

    2005-10-01

    Full Text Available Abstract Background Previous research has shown positive effects of music therapy for people with schizophrenia and other mental disorders. In clinical practice, music therapy is often offered to psychiatric patients with low therapy motivation, but little research exists about this population. The aim of this study is to examine whether resource-oriented music therapy helps psychiatric patients with low therapy motivation to improve negative symptoms and other health-related outcomes. An additional aim of the study is to examine the mechanisms of change through music therapy. Methods 144 adults with a non-organic mental disorder (ICD-10: F1 to F6 who have low therapy motivation and a willingness to work with music will be randomly assigned to an experimental or a control condition. All participants will receive standard care, and the experimental group will in addition be offered biweekly sessions of music therapy over a period of three months. Outcomes will be measured by a blind assessor before and 1, 3, and 9 months after randomisation. Discussion The findings to be expected from this study will fill an important gap in the knowledge of treatment effects for a patient group that does not easily benefit from treatment. The study's close link to clinical practice, as well as its size and comprehensiveness, will make its results well generalisable to clinical practice.

  1. Epithermal neutron beam adoption for liver cancer treatment by boron and gadolinium neutron capture therapy

    International Nuclear Information System (INIS)

    Comparative evaluation was made on depth-dose distribution in boron neutron capture therapy (B-NCT) and gadolinium one (Gd-NCT) for the treatments of liver cancers. At present, epithermal neutron beam is expected to be applicable to the treatment of deep and widespread tumors. ICRU computational model of ADAM and EVA was used as a liver phantom loading a tumor at depth of 6 cm in its central region. Epithermal neutron beam of Musashi reactor was used as the primary neutron beam for the depth-dose calculation. Calculation was conducted using the three-dimensional continuous-energy Monte Carlo code MCNP4A. The doses observed in both NCTs were bumped over the tumor region but the dose for Gd-NCT was not so tumor-specific compared with that for BNCT because radiation in Gd-NCT was due to γ-ray. The mean physical dose was 4 Gy/h for boron 30 ppm and 5 Gy/h for Gd 1000 ppm when exposed to an epithermal neutron flux of 5x108 n/cm-2/sec and the dose ratio of tumor-to normal tissue was 2.7 for boron and 2.5 for Gd. The lethal dose of 50 Gy for the liver can be accomplished under conditions where the dose has not reached 25 Gy, the tolerance dose of the normal tissue. This seems very encouraging and indicating that both B-NCT and Gd-NCT are applicable for the treatment for liver cancer. However, if normal tissue contain 1/4 of the tumor concentration of boron or Gd, the BNCT would still possible when considering a large RBE value for 10B(n, α) reaction but the Gd-NCT would impossible for deep liver treatment. (M.N.)

  2. Epithermal neutron beam adoption for liver cancer treatment by boron and gadolinium neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Tetsuo [Musashi Inst. of Tech., Kawasaki, Kanagawa (Japan). Atomic Energy Research Lab

    2001-06-01

    Comparative evaluation was made on depth-dose distribution in boron neutron capture therapy (B-NCT) and gadolinium one (Gd-NCT) for the treatments of liver cancers. At present, epithermal neutron beam is expected to be applicable to the treatment of deep and widespread tumors. ICRU computational model of ADAM and EVA was used as a liver phantom loading a tumor at depth of 6 cm in its central region. Epithermal neutron beam of Musashi reactor was used as the primary neutron beam for the depth-dose calculation. Calculation was conducted using the three-dimensional continuous-energy Monte Carlo code MCNP4A. The doses observed in both NCTs were bumped over the tumor region but the dose for Gd-NCT was not so tumor-specific compared with that for BNCT because radiation in Gd-NCT was due to {gamma}-ray. The mean physical dose was 4 Gy/h for boron 30 ppm and 5 Gy/h for Gd 1000 ppm when exposed to an epithermal neutron flux of 5x10{sup 8} n/cm{sup -2}/sec and the dose ratio of tumor-to normal tissue was 2.7 for boron and 2.5 for Gd. The lethal dose of 50 Gy for the liver can be accomplished under conditions where the dose has not reached 25 Gy, the tolerance dose of the normal tissue. This seems very encouraging and indicating that both B-NCT and Gd-NCT are applicable for the treatment for liver cancer. However, if normal tissue contain 1/4 of the tumor concentration of boron or Gd, the BNCT would still possible when considering a large RBE value for {sup 10}B(n, {alpha}) reaction but the Gd-NCT would impossible for deep liver treatment. (M.N.)

  3. Clinical aspects of boron neutron capture therapy

    International Nuclear Information System (INIS)

    Boron neutron capture therapy is potentially useful in treating malignant tumors of the central nervous system and is technically possible. Additional in vitro and in vivo testing is required to determine toxicities, normal tissue tolerances and tissue responses to treatment parameters. Adequate tumor uptake of the capture agent can be evaluated clinically prior to implementation of a finalized treatment protocol. Phase I and Phase II protocol development, clinical pharmacokinetic studies and neutron beam development

  4. Gadolinium as a Neutron Capture Therapy Agent

    Science.gov (United States)

    Shih, Jing-Luen Allen

    The clinical results of treating brain tumors with boron neutron capture therapy are very encouraging and researchers around the world are once again making efforts to develop this therapeutic modality. Boron-10 is the agent receiving the most attention for neutron capture therapy but ^{157}Gd is a nuclide that also holds interesting properties of being a neutron capture therapy agent. The objective of this study is to evaluate ^{157}Gd as a neutron capture therapy agent. In this study it is determined that tumor concentrations of about 300 mug ^{157}Gd/g tumor can be achieved in brain tumors with some FDA approved MRI contrast agents such as Gd-DTPA and Gd-DOTA, and up to 628 mug ^{157 }Gd/g tumor can be established in bone tumors with Gd-EDTMP. Monte Carlo calculations show that with only 250 ppm of ^{157}Gd in tumor, neutron capture therapy can deliver 2,000 cGy to a tumor of 2 cm diameter or larger with 5 times 10^{12} n/cm ^2 fluence at the tumor. Dose measurements which were made with films and TLD's in phantoms verified these calculations. More extended Monte Carlo calculations demonstrate that neutron capture therapy with Gd possesses comparable dose distribution to B neutron capture therapy. With 5 times 10^{12 } n/cm^2 thermal neutrons at the tumor, Auger electrons from the Gd produced an optical density enhancement on the films that is similar to the effect caused by about 300 cGy of Gd prompt gamma dose which will further enhance the therapeutic effects. A technique that combines brachytherapy with Gd neutron capture therapy has been evaluated. Monte Carlo calculations show that 5,000 cGy of prompt gamma dose can be delivered to a treatment volume of 40 cm^3 with a 3-plane implant of a total of 9 Gd needles. The tumor to normal tissue advantage of this method is as good as ^{60} Co brachytherapy. Measurements of prompt gamma dose with films and TLD-700's in a lucite phantom verify the Monte Carlo evaluation. A technique which displays the Gd

  5. A Randomized Trial of Behavioral Physical Therapy Interventions for Acute and Sub-Acute Low Back Pain (NCT00373867)

    OpenAIRE

    George, Steven Z.; Zeppieri, Giorgio; Cere, Anthony L.; Cere, Melissa R.; Borut, Michael S.; Hodges, Michael J.; Reed, Dalton M.; Valencia, Carolina; Robinson, Michael E.

    2008-01-01

    Psychological factors consistent with fear-avoidance models are associated with the development of chronic low back pain (LBP). As a result, graded activity (GA) and graded exposure (GX) have been suggested as behavioral treatment options. This clinical trial compared the effectiveness of treatment based classification (TBC) physical therapy alone, to TBC augmented with GA or GX for patients with acute and sub-acute LBP. Our primary hypothesis was that GX would be most effective for those wit...

  6. Neutron capture therapy of ocular melanoma: dosimetry and microdosimetry approaches; Therapie par capture de neutrons des melanomes oculaires: approches dosimetrique et microdosimetrique

    Energy Technology Data Exchange (ETDEWEB)

    Pignol, J.P.; Methlin, G. [Centre Paul Strauss, 67 - Strasbourg (France); Abbe, J.C. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Stampfler, A. [Strasbourg-1 Univ., 67 (France); Lefebvre, O. [Faculte de Medecine, 67 - Strasbourg (France); Sahel, J. [Centre Hospitalier Universitaire, 67 - Strasbourg (France)

    1994-06-01

    Neutron capture therapy (NCT) aims at destroying cancerous cells with the {alpha} and {sup 7}Li particles produced by the neutron capture reaction on {sup 10}B. This note reports on the study of the boron distribution in tissues on an animal model (nude mice) xenografted with a human ocular melanoma after an i.p.injection of 2g/kg of {sup 10}B-BPA and in cells cultured in the presence of 530 {mu}mol/l of {sup 10}B-BPA. A concentration of 64 ppm of {sup 10}B in the active part of the tumour with a ratio of concentrations versus the skin of 3.7 are observed. Investigations on cells reveal the presence of boron in the cytoplasm. The biological, dosimetric and microdosimetric consequences of these findings are discussed. (authors). 15 refs., 2 tabs., 2 figs.

  7. Spectromicroscopy in Boron Neutron Capture Therapy Research

    Science.gov (United States)

    Gilbert, Benjamin; Redondo, Jose; Andres, Roger; Suda, Takashi; Neumann, Michael; Steen, Steffi; Gabel, Detlef; Mercanti, Delio; Ciotti, Teresa; Perfetti, Paolo; Margaritondo, Giorgio; de Stasio, Gelsomina

    1998-03-01

    The MEPHISTO synchrotron imaging spectromicroscope can analyse ashed cells or tissue sections to reveal the microdistribution of trace elements. MEPHISTO performs core level x-ray absorption spectroscopy with synchrotron radiation, and uses an electron optics system to provide magnified photoelectron images. An application of the MEPHISTO spectromicroscope is in boron neutron capture therapy (BNCT). BNCT is a binary cancer therapy that will selectively destroy cancer cells provided that compounds containing a boron isotope are selectively accumulated in tumor tissue. Important factors for the success of BNCT include the ability to target every cancer cell, and the distribution of boron inside the cell. To investigate the boron distribution in tissue, sections of human glioblastoma containing a BNCT compound, and stained with nickel against a protein found in the nuclei of proliferating (cancer) cells, were studied with MEPHISTO.

  8. Microdosimetry for Boron Neutron Capture Therapy

    International Nuclear Information System (INIS)

    The specific aims of the research proposal were as follows: (1) To design and construct small volume tissue equivalent proportional counters for the dosimetry and microdosimetry of high intensity thermal and epithermal neutron beams used in BNCT, and of modified fast neutron beams designed for boron neutron capture enhanced fast neutron therapy (BNCEFNT). (2) To develop analytical methods for estimating the biological effectiveness of the absorbed dose in BNCT and BNCEFNT based on the measured microdosimetric spectra. (3) To develop an analytical framework for comparing the biological effectiveness of different epithermal neutron beams used in BNCT and BNCEFNT, based on correlated sets of measured microdosimetric spectra and radiobiological data. Specific aims (1) and (2) were achieved in their entirety and are comprehensively documented in Jay Burmeister's Ph.D. dissertation entitled ''Specification of physical and biologically effective absorbed dose in radiation therapies utilizing the boron neutron capture reaction'' (Wayne State University, 1999). Specific aim (3) proved difficult to accomplish because of a lack of sufficient radiobiological data

  9. Dual antiplatelet therapy in patients with aspirin resistance following coronary artery bypass grafting: study protocol for a randomized controlled trial [NCT01159639

    Directory of Open Access Journals (Sweden)

    Gasparovic Hrvoje

    2012-08-01

    Full Text Available Abstract Background Coronary artery disease remains the dominant cause of mortality in developed countries. While platelets have been recognized to play a pivotal role in atherothrombosis, the ideal antiplatelet regime after coronary artery surgery remains elusive. The evolution of CABG has presently moved beyond technical improvements to involve modulation of pharmacologic management designed to improve patient outcomes. The aim of this trial will be to test the hypothesis that the addition of clopidogrel to patients with documented postoperative aspirin resistance will reduce the incidence of major cardiovascular events. Methods Patients scheduled for isolated coronary artery surgery will be eligible for the study. Patients in whom postoperative multiple electrode aggregometry documents aspirin resistance will be randomized into two groups. The control group will receive 300 mg of aspirin. The dual antiplatelet group will receive 75 mg of clopidogrel in addition to 300 mg of aspirin. Patients will be followed for 6 months. Major adverse cardiac and cerebrovascular events (death from any cause, myocardial infarction, stroke, hospitalization due to cardiovascular pathology as well as bleeding events will be recorded. Discussion This will be the first trial that will specifically address the issue of dual antiplatelet therapy in patients undergoing coronary artery surgery who have been found to be aspirin resistant. In the event that the addition of clopidogrel proves to be beneficial in this subset of surgical patients, this study could significantly impact their future antiplatelet management. This randomized controlled trial has been registered at the ClinicalTrials.gov website (Identifier NCT01159639.

  10. Randomised phase II trial (NCT00637975 evaluating activity and toxicity of two different escalating strategies for pregabalin and oxycodone combination therapy for neuropathic pain in cancer patients.

    Directory of Open Access Journals (Sweden)

    Marina Chiara Garassino

    Full Text Available PURPOSE: Neuropathic pain is commonly associated with cancer. Current treatments include combination opioid and adjuvant therapies, but no guidelines are available for dose escalation strategies. This phase II study compared the efficacy and tolerability of two dose escalation strategies for oxycodone and pregabalin combination therapy. METHODS: Patients (N = 75 with oncological neuropathic pain, previously untreated with pregabalin, were recruited in 5 Italian institutions between 2007 and 2010. Patients were randomised to two different dose escalation strategies (arm A; N = 38 oxycodone at a fixed dose with increasing pregabalin doses; (arm B; N = 37 pregabalin at a fixed dose with increasing oxycodone doses. Patients were evaluated from daily diaries and follow-ups at 3, 7, 10, and 14 days after beginning treatment with a numerical rating scale (NRS, neuropathic pain scale (SDN, and well-being scale (ESAS. The primary endpoint was a ≥1/3 reduction in pain (NRS; secondary endpoints included the time to analgesia and adverse effects. The study had a 90% probability of detecting the best strategy for a true difference of at least 15%. RESULTS: More patients in arm A (76% than arm B (64% achieved ≥1/3 overall pain reduction even after controlling for baseline factors (gender, baseline pain. Group A reported fewer side effects than group B; constipation 52.8% vs. 66.7%; nausea: 27.8% vs. 44.4%; drowsiness: 44.4% vs. 55.6%; confusion: 16.7% vs. 27.8%; itching: 8.3% vs. 19.4%. CONCLUSIONS: Both strategies effectively controlled neuropathic pain, but according to the adopted selection design arm A is preferable to arm B for pain control. TRIAL REGISTRATION: ClinicalTrials.gov NCT00637975.

  11. Role of the Tapiro Fast Research Reactor in Neutron Capture Therapy in Italy Calculations and Measurements

    International Nuclear Information System (INIS)

    Thermal-neutron research reactors are currently the most common source of neutron beams for both research and clinical trials of neutron capture therapy (NCT). Neutron spectra suitable for NCT are typically produced either by beam filtering or spectrum shifting techniques. However, fast-neutron reactors are also being considered for NCT application as it is recognized that they may allow for improved beam quality. TAPIRO is a low power, high flux, highly enriched (93.5% 235U) fast reactor. The power is 5 kW and the maximum neutron flux in the core is 3x1012 cm-2.s-1. Both a thermal and an epithermal column have been designed and constructed, aimed at dosimetry and animal experiments. The configurations of the columns have been designed by means of Monte Carlo calculations. The columns have been characterized by means of measurements performed with activation techniques and thermoluminescence and gel dosimeters. Experimental results have shown good consistency with calculations. Moreover, they have confirmed the good quality of the beams obtainable with such a reactor. An epithermal column for clinical trials of patients with brain gliomas has been designed and is under construction. The treatment planning figures-of-merit in an anthropomorphic phantom look very satisfactory. (author)

  12. Considerations for boron neutron capture therapy studies

    International Nuclear Information System (INIS)

    Radiotherapy is indispensable as a mean to eradicate deeply or infiltrating tumor tissue that can not be removed surgically. Therefore, it is not selective and may also kill the surrounding health tissue. The principle of BNCT (Boron Neutron Capture Therapy) consist in targeting a tumor selectively with a boron-10 compound. This nuclide has a large capture cross section for thermal neutrons and the nuclear reaction and the delivered energy in locus will selective the tumor. Since its initial proposal in 1963 BNCT has made much progress, however it is not used in a routine treatment. In this work it was approached some complex procedures, as the obtention of selective boron compounds, the adequate set up of neutron beams, the biodistribution, the in vivo and in vitro studies, and also human patients treatments. This work provide fundamentals about BNCT to professional of different areas of knowledge since it comprises multidisciplinary study. It includes appendixes for the ones not related to the field for a better comprehension of the many aspects involved. It is also presented a glossary containing technical and basic aspects involved. It is also presented a glossary containing technical and basic terms referred in the work. (author). 174 refs, 1 fig, 12 apps

  13. Tumor growth suppression by gadolinium-neutron capture therapy using gadolinium-entrapped liposome as gadolinium delivery agent.

    Science.gov (United States)

    Dewi, Novriana; Yanagie, Hironobu; Zhu, Haito; Demachi, Kazuyuki; Shinohara, Atsuko; Yokoyama, Kazuhito; Sekino, Masaki; Sakurai, Yuriko; Morishita, Yasuyuki; Iyomoto, Naoko; Nagasaki, Takeshi; Horiguchi, Yukichi; Nagasaki, Yukio; Nakajima, Jun; Ono, Minoru; Kakimi, Kazuhiro; Takahashi, Hiroyuki

    2013-07-01

    Neutron capture therapy (NCT) is a promising non-invasive cancer therapy approach and some recent NCT research has focused on using compounds containing gadolinium as an alternative to currently used boron-10 considering several advantages that gadolinium offers compared to those of boron. In this study, we evaluated gadolinium-entrapped liposome compound as neutron capture therapy agent by in vivo experiment on colon-26 tumor-bearing mice. Gadolinium compound were injected intravenously via tail vein and allowed to accumulate into tumor site. Tumor samples were taken for quantitative analysis by ICP-MS at 2, 12, and 24 h after gadolinium compound injection. Highest gadolinium concentration was observed at about 2 h after gadolinium compound injection with an average of 40.3 μg/g of wet tumor tissue. We performed neutron irradiation at JRR-4 reactor facility of Japan Atomic Energy Research Institute in Tokaimura with average neutron fluence of 2×10¹² n/cm². The experimental results showed that the tumor growth suppression of gadolinium-injected irradiated group was revealed until about four times higher compared to the control group, and no significant weight loss were observed after treatment suggesting low systemic toxicity of this compound. The gadolinium-entrapped liposome will become one of the candidates for Gd delivery system on NCT.

  14. Research needs for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    Key issues and questions addressed by the workshop related to optimization of Boron Neutron Capture Therapy (BNCT), in general, and to the possibility of success of the present BNCT trials at Brookhaven National Laboratory (BNL) and Massachusetts Institute of Technology (MIT), in particular. Both trials use nuclear fission reactors as neutron sources for BNCT of glioblastoma multiforme (BNL) and of deep seated melanoma (MIT). Presentations and discussions focussed on optimal boron-labeled compounds, mainly for brain tumors such as glioblastoma multiforme, and the best mode of compound delivery to the tumor. Also, optimizing neutron irradiation with dose delivery to the tumor cells and the issues of dosimetry of BNCT especially in the brain were discussed. Planning of treatment and of follow-up of patients, coordination of BNCT at various treatment sites, and the potential of delivering BNCT to various types of cancer with an appropriately tailored protocol were additional issues. The need for multicentric interdisciplinary cooperation among the different medical specialties was highlighted.

  15. Research needs for neutron capture therapy

    International Nuclear Information System (INIS)

    Key issues and questions addressed by the workshop related to optimization of Boron Neutron Capture Therapy (BNCT), in general, and to the possibility of success of the present BNCT trials at Brookhaven National Laboratory (BNL) and Massachusetts Institute of Technology (MIT), in particular. Both trials use nuclear fission reactors as neutron sources for BNCT of glioblastoma multiforme (BNL) and of deep seated melanoma (MIT). Presentations and discussions focussed on optimal boron-labeled compounds, mainly for brain tumors such as glioblastoma multiforme, and the best mode of compound delivery to the tumor. Also, optimizing neutron irradiation with dose delivery to the tumor cells and the issues of dosimetry of BNCT especially in the brain were discussed. Planning of treatment and of follow-up of patients, coordination of BNCT at various treatment sites, and the potential of delivering BNCT to various types of cancer with an appropriately tailored protocol were additional issues. The need for multicentric interdisciplinary cooperation among the different medical specialties was highlighted

  16. Neutron capture therapy: Years of experimentation---Years of reflection

    International Nuclear Information System (INIS)

    This report describes early research on neutron capture therapy over a number of years, beginning in 1950, speaking briefly of patient treatments but dwelling mostly on interpretations of our animal experiments. This work carried out over eighteen years, beginning over forty years ago. Yet, it is only fitting to start by relating how neutron capture therapy became part of Brookhaven's Medical Research Center program

  17. Design and Simulation of a New Model for Treatment by NCT

    Directory of Open Access Journals (Sweden)

    Seyed Alireza Mousavi Shirazi

    2012-01-01

    Full Text Available In this investigation, neutron capture therapy (NCT through high energy neutrons using Monte Carlo method has been studied. In this study a new method of NCT for a sample liver phantom has been defined, and interaction of 12 MeV neutrons with a multilayer spherical phantom is considered. In order to reach the desirable energy range of neutrons in accord with required energy in absence of eligible clinical neutron source for NCT, this model of phantom might be utilized. The neutron flux and the deposited dose in the all components and different layers of the mentioned phantom are computed by Monte Carlo simulation. The results of Monte Carlo method are compared with analytical method results so that by using a computer program in Turbo-Pascal programming, the deposited dose in the liver phantom has been computed.

  18. Advances in neutron capture therapy 2006. Proceedings of 12th international congress on neutron capture therapy

    International Nuclear Information System (INIS)

    The Twelfth International Congress on Neutron Capture Therapy (ICNCT-12) is being held from October 9th to 13th, 2006 at the Kagawa International Congress Hall in Takamatsu, Kagawa, Japan. The main theme of the congress is From the past to the Future'. Five symposiums were organized to accommodate all the contributions from the international scientific committees of the International Society for Neutron Capture Therapy (ISNCT), and two symposiums were added to balance the number of fields of specialties. The seven symposiums for ICNCT-12 are as follows: 1) Clinical Results of BNCT for Brain Tumors, 2) Dosimetry, 3) Treatment Planning system, 4) Drug Delivery System, 5) Biomedical and General Matters, 6) BNCT Systems using Accelerators, 7) New Applications and Protocols for BNCT. There are a total of 195 presentations in this congress: 3 special lectures, 34 symposium presentations, 10 presentations in two special sessions from the recipients of the Ralph G. Fairchild Award, 70 presentations in the oral parallel sessions and 78 presentations in the poster sessions. A compilation of 169 papers are published in this proceedings. The 165 of the presented papers are indexed individually. (J.P.N.)

  19. Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models.

    Science.gov (United States)

    Goorley, J T; Kiger, W S; Zamenhof, R G

    2002-02-01

    As clinical trials of Neutron Capture Therapy (NCT) are initiated in the U.S. and other countries, new treatment planning codes are being developed to calculate detailed dose distributions in patient-specific models. The thorough evaluation and comparison of treatment planning codes is a critical step toward the eventual standardization of dosimetry, which, in turn, is an essential element for the rational comparison of clinical results from different institutions. In this paper we report development of a reference suite of computational test problems for NCT dosimetry and discuss common issues encountered in these calculations to facilitate quantitative evaluations and comparisons of NCT treatment planning codes. Specifically, detailed depth-kerma rate curves were calculated using the Monte Carlo radiation transport code MCNP4B for four different representations of the modified Snyder head phantom, an analytic, multishell, ellipsoidal model, and voxel representations of this model with cubic voxel sizes of 16, 8, and 4 mm. Monoenergetic and monodirectional beams of 0.0253 eV, 1, 2, 10, 100, and 1000 keV neutrons, and 0.2, 0.5, 1, 2, 5, and 10 MeV photons were individually simulated to calculate kerma rates to a statistical uncertainty of neutron beam with a broad neutron spectrum, similar to epithermal beams currently used or proposed for NCT clinical trials, was computed for all models. The thermal neutron, fast neutron, and photon kerma rates calculated with the 4 and 8 mm voxel models were within 2% and 4%, respectively, of those calculated for the analytical model. The 16 mm voxel model produced unacceptably large discrepancies for all dose components. The effects from different kerma data sets and tissue compositions were evaluated. Updating the kerma data from ICRU 46 to ICRU 63 data produced less than 2% difference in kerma rate profiles. The depth-dose profile data, Monte Carlo code input, kerma factors, and model construction files are available

  20. Optimal Neutron Source and Beam Shaping Assembly for Boron Neutron Capture Therapy

    CERN Document Server

    Vujic, J L; Greenspan, E; Guess, S; Karni, Y; Kastenber, W E; Kim, L; Leung, K N; Regev, D; Verbeke, J M; Waldron, W L; Zhu, Y

    2003-01-01

    There were three objectives to this project: (1) The development of the 2-D Swan code for the optimization of the nuclear design of facilities for medical applications of radiation, radiation shields, blankets of accelerator-driven systems, fusion facilities, etc. (2) Identification of the maximum beam quality that can be obtained for Boron Neutron Capture Therapy (BNCT) from different reactor-, and accelerator-based neutron sources. The optimal beam-shaping assembly (BSA) design for each neutron source was also to e obtained. (3) Feasibility assessment of a new neutron source for NCT and other medical and industrial applications. This source consists of a state-of-the-art proton or deuteron accelerator driving and inherently safe, proliferation resistant, small subcritical fission assembly.

  1. Optimal Neutron Source and Beam Shaping Assembly for Boron Neutron Capture Therapy

    International Nuclear Information System (INIS)

    There were three objectives to this project: (1) The development of the 2-D Swan code for the optimization of the nuclear design of facilities for medical applications of radiation, radiation shields, blankets of accelerator-driven systems, fusion facilities, etc. (2) Identification of the maximum beam quality that can be obtained for Boron Neutron Capture Therapy (BNCT) from different reactor-, and accelerator-based neutron sources. The optimal beam-shaping assembly (BSA) design for each neutron source was also to e obtained. (3) Feasibility assessment of a new neutron source for NCT and other medical and industrial applications. This source consists of a state-of-the-art proton or deuteron accelerator driving and inherently safe, proliferation resistant, small subcritical fission assembly

  2. Accelerator based neutron source for the neutron capture therapy at hospital

    International Nuclear Information System (INIS)

    Accelerator source of epithermal neutrons for the hospital-based boron neutron capture therapy is proposed and discussed. Kinematically collimated neutrons are produced via near-threshold 7Li(p, n)7Be reaction at proton energies of 1.883 - 1.9 MeV. Steady-state accelerator current of 40 mA allows to provide therapeutically useful beams with treatment times of tens of minutes. The basic components of the facility are a hydrogen negative ion source, an electrostatic tandem accelerator with vacuum insulation, a sectioned rectifier, and a thin lithium neutron generating target on the surface of tungsten disk cooled by liquid metal heat carrier. Design features of facility components are discussed. The possibility of stabilization of proton energy is considered. At proton energy of 2.5 MeV the neutron beam production for NCT usage after moderation is also considered. (author)

  3. Optimal Neutron Source & Beam Shaping Assembly for Boron Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    J. Vujic; E. Greenspan; W.E. Kastenber; Y. Karni; D. Regev; J.M. Verbeke, K.N. Leung; D. Chivers; S. Guess; L. Kim; W. Waldron; Y. Zhu

    2003-04-30

    There were three objectives to this project: (1) The development of the 2-D Swan code for the optimization of the nuclear design of facilities for medical applications of radiation, radiation shields, blankets of accelerator-driven systems, fusion facilities, etc. (2) Identification of the maximum beam quality that can be obtained for Boron Neutron Capture Therapy (BNCT) from different reactor-, and accelerator-based neutron sources. The optimal beam-shaping assembly (BSA) design for each neutron source was also to e obtained. (3) Feasibility assessment of a new neutron source for NCT and other medical and industrial applications. This source consists of a state-of-the-art proton or deuteron accelerator driving and inherently safe, proliferation resistant, small subcritical fission assembly.

  4. Accumulation of MRI contrast agents in malignant fibrous histiocytoma for gadolinium neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, T. [Department of Orthopaedic Surgery, Hyogo Cancer Center, Akashi 673-0021 (Japan)], E-mail: fujitaku@hp.pref.hyogo.jp; Ichikawa, H. [Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, Kobe 650-8586 (Japan); Akisue, T. [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Fujita, I. [Department of Orthopaedic Surgery, Hyogo Cancer Center, Akashi 673-0021 (Japan); Kishimoto, K.; Hara, H. [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Imabori, M. [Department of Orthopaedic Surgery, Hyogo Cancer Center, Akashi 673-0021 (Japan); Kawamitsu, H. [Department of Radiology, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Sharma, P.; Brown, S.C.; Moudgil, B.M. [Particle Engineering Research Center, University of Florida, Gainesville, FL32611 (United States); Fujii, M. [Department of Radiology, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Yamamoto, T. [Department of Orthopaedic Surgery, Kagawa University, Kagawa 761-0793 (Japan); Kurosaka, M. [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Fukumori, Y. [Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, Kobe 650-8586 (Japan)

    2009-07-15

    Neutron-capture therapy with gadolinium (Gd-NCT) has therapeutic potential, especially that gadolinium is generally used as a contrast medium in magnetic resonance imaging (MRI). The accumulation of gadolinium in a human sarcoma cell line, malignant fibrosis histiocytoma (MFH) Nara-H, was visualized by the MRI system. The commercially available MRI contrast medium Gd-DTPA (Magnevist, dimeglumine gadopentetate aqueous solution) and the biodegradable and highly gadopentetic acid (Gd-DTPA)-loaded chitosan nanoparticles (Gd-nanoCPs) were prepared as MRI contrast agents. The MFH cells were cultured and collected into three falcon tubes that were set into the 3-tesra MRI system to acquire signal intensities from each pellet by the spin echo method, and the longitudinal relaxation time (T1) was calculated. The amount of Gd in the sample was measured by inductively coupled plasma atomic emission spectrography (ICP-AES). The accumulation of gadolinium in cells treated with Gd-nanoCPs was larger than that in cells treated with Gd-DTPA. In contrast, and compared with the control, Gd-DTPA was more effective than Gd-nanoCPs in reducing T1, suggesting that the larger accumulation exerted the adverse effect of lowering the enhancement of MRI. Further studies are warranted to gain insight into the therapeutic potential of Gd-NCT.

  5. Intermediate-energy neutron beam for NCT at MURR

    International Nuclear Information System (INIS)

    The University of Missouri Research Reactor (MURR) is one of the high-flux reactors in the USA and it can be used to produce an intense beam of intermediate-energy neutrons for neutron capture therapy. Two methods are being evaluated at MURR to produce such a beam. The first uses a moderator of Al2O3 replacing part of the graphite and water on one side of the core of the reactor to produce a source of predominantly intermediate-energy neutrons. The second method is a filter of 238U between the core and the patient position to pass only intermediate-energy neutrons. The results of these evaluations are presented in this paper along with an outline of the other resources at the University of Missouri-Columbia that are available to support an NCT program. 4 references, 7 figures, 1 table

  6. Synthesis of samarium binding bleomycin - a possible NCT radiosensitizer

    International Nuclear Information System (INIS)

    Bleomycin (BLM) is a drug that has attractive features for the development of a new radiopharmaceutical, particularly with regard to neutron capture therapy (NCT) sensitized by Sm-149. It has the ability to chelate many metal ions. In vitro studies have shown that up to 78% of BLM present in a cell is accumulated inside the nucleus or in the nuclear membrane. In addition, this drug has higher affinity for tumor tissues than for normal tissues. Radioactive isotopes carried by this antibiotic would be taken preferentially to one important cellular targets DNA. Besides, BLM displays intrinsic anti-tumor activity - it is a chemotherapic antibiotic clinically used against some cancers. This study aimed to obtain bleomycin molecules bound to samarium (BLM-Sm) for NCT studies in vitro and in vivo. The binding technique employed in this work has great simplicity and low cost. Thin layer chromatography, high performance liquid chromatography, fast protein liquid chromatography and analysis by ICP-AES were applied to verify the binding molecule. ICP-AES results showed the presence of samarium in the sample peaks related to BLM-Sm. However, efficiency and stability of this bond needs to be investigated. (author)

  7. Synthesis of samarium binding bleomycin - a possible NCT radiosensitizer

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, B.M., E-mail: bmm@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Mendes, T.M.; Campos, T.P.R., E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Bleomycin (BLM) is a drug that has attractive features for the development of a new radiopharmaceutical, particularly with regard to neutron capture therapy (NCT) sensitized by Sm-149. It has the ability to chelate many metal ions. In vitro studies have shown that up to 78% of BLM present in a cell is accumulated inside the nucleus or in the nuclear membrane. In addition, this drug has higher affinity for tumor tissues than for normal tissues. Radioactive isotopes carried by this antibiotic would be taken preferentially to one important cellular targets DNA. Besides, BLM displays intrinsic anti-tumor activity - it is a chemotherapic antibiotic clinically used against some cancers. This study aimed to obtain bleomycin molecules bound to samarium (BLM-Sm) for NCT studies in vitro and in vivo. The binding technique employed in this work has great simplicity and low cost. Thin layer chromatography, high performance liquid chromatography, fast protein liquid chromatography and analysis by ICP-AES were applied to verify the binding molecule. ICP-AES results showed the presence of samarium in the sample peaks related to BLM-Sm. However, efficiency and stability of this bond needs to be investigated. (author)

  8. Recent progress of basic studies for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Koji [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst

    2001-01-01

    Epi-thermal neutron irradiation for malignant brain tumors is the mainstream of recent studies in boron neutron capture therapy. To improve the depth dose distribution in water phantom, a LiF plate (5 mmt, 6 cm {phi}) is located in the front of center axis of KUR irradiation field. Thermal neutron flux at the center surface of the water phantom is shielded by the LiF plate. The depth and peripheral dose distribution of thermal neutron flux becomes to uniform. The boron dose at 6 cm in the depths of the phantom increases to about 1.71 times greater than the usual irradiation field. Two-kinds of nuclear medicines, Na{sub 2}B{sub 12}H{sub 11}SH(BSH) and Borono Phenyl Alanine (BPA), have been used for boron neutron capture therapy. BPA-ol, a new medicine of modified compound of the BPA can be used effectively on hyperthermia of cancer parts to 42 - 43degC. Cell death and mutagenesis of chinese hamster ovary cells (CHO) after pre-incubation with BPA and BSH are investigated for the validity of boron neutron capture therapy. The effects of BSH on the cell death and the mutagenesis are few in comparison with those of BPA. It is thought that the BSH is not accumulated in the cell. The effects of boron neutron capture therapy on sensitivity of intratumor quiescent and total cells are investigated. (Suetake, M.)

  9. Proceedings of the first international symposium on neutron capture therapy

    International Nuclear Information System (INIS)

    This meeting was arranged jointly by MIT and BNL in order to illuminate progress in the synthesis and targeting of boron compounds and to evaluate and document progress in radiobiological and dosimetric aspects of neutron capture therapy. It is hoped that this meeting will facilitate transfer of information between groups working in these fields, and encourage synergistic collaboration

  10. Proceedings of the first international symposium on neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.; Brownell, G.L. (eds.)

    1982-01-01

    This meeting was arranged jointly by MIT and BNL in order to illuminate progress in the synthesis and targeting of boron compounds and to evaluate and document progress in radiobiological and dosimetric aspects of neutron capture therapy. It is hoped that this meeting will facilitate transfer of information between groups working in these fields, and encourage synergistic collaboration.

  11. Treatment of non-small cell lung cancer with intensity-modulated radiation therapy in combination with cetuximab: the NEAR protocol (NCT00115518

    Directory of Open Access Journals (Sweden)

    Hoess A

    2006-05-01

    Full Text Available Abstract Background Even today, treatment of Stage III NSCLC still poses a serious challenge. So far, surgical resection is the treatment of choice. Patients whose tumour is not resectable or who are unfit to undergo surgery are usually referred to a combined radio-chemotherapy. However, combined radio-chemotherapeutic treatment is also associated with sometimes marked side effects but has been shown to be more efficient than radiation therapy alone. Nevertheless, there is a significant subset of patients whose overall condition does not permit administration of chemotherapy in a combined-modality treatment. It could be demonstrated though, that NSCLCs often exhibit over-expression of EGF-receptors hence providing an excellent target for the monoclonal EGFR-antagonist cetuximab (Erbitux® which has already been shown to be effective in colorectal as well as head-and-neck tumours with comparatively mild side-effects. Methods/design The NEAR trial is a prospective phase II feasibility study combining a monoclonal EGF-receptor antibody with loco-regional irradiation in patients with stage III NSCLC. This trial aims at testing the combination's efficacy and rate of development of distant metastases with an accrual of 30 patients. Patients receive weekly infusions of cetuximab (Erbitux® plus loco-regional radiation therapy as intensity-modulated radiation therapy. After conclusion of radiation treatment patients continue to receive weekly cetuximab for 13 more cycles. Discussion The primary objective of the NEAR trial is to evaluate toxicities and feasibility of the combined treatment with cetuximab (Erbitux® and IMRT loco-regional irradiation. Secondary objectives are remission rates, 3-year-survival and local/systemic progression-free survival.

  12. Medical and biological requirements for boron neutron capture therapy

    International Nuclear Information System (INIS)

    In conventional radiation therapy, tumor doses applied to most solid tumors are limited by the tolerance of normal tissues. The promise of Boron Neutron Capture Therapy lies in its potential to deposit high doses of radiation very specifically to tumor tissue. Theoretically ratios of tumor to normal tissue doses can be achieved significantly higher than conventional radiotherapeutic techniques would allow. Effective dose distributions obtainable are a complex function of the neutron beam characteristics and the macro and micro distributions of boron in tumor and normal tissues. Effective RBE doses are calculated in tumors and normal tissue for thermal, epithermal and 2 keV neutrons

  13. Electroporation increases the effect of borocaptate (10B-BSH) in neutron capture therapy

    International Nuclear Information System (INIS)

    Purpose: The cell membrane permeability of borocaptate (10B-BSH) and its extent of accumulation in cells are controversial. This study was performed to elucidate these points. Methods and Materials: Two different treatments were applied to SCCVII tumor cells. The first group of tumor cells was incubated in culture medium with 10B-BSH or 10B-enriched boric acid, and was exposed to neutrons from the heavy water facility of the Kyoto University Reactor (KUR). More than 99% of neutrons were thermal neutrons at flux base. The second group was pretreated by electroporation in combination with 10B-BSH, and thereafter the cells were irradiated with neutrons. The cell killing effects of boron neutron capture therapy (BNCT) using BSH were investigated by colony formation assay. Results: Surviving cell fraction decreased exponentially with neutron fluence, and addition of BSH significantly enhanced the cell killing effect of neutron capture therapy (NCT) depending on 10B concentration. The effect of BSH-BNCT also increased with preincubation time of cells in the medium containing BSH. The electroporation of cells with BSH at 10 ppm 10B markedly enhanced BSH-BNCT effects in comparison with that of preincubation alone. The effect of BSH-BNCT with electroporation was equal to that of BNCT using 10B-boric acid at a same 10B concentration (10 ppm). Conclusions: BSH is suggested to penetrate the cells slowly and remained after washing. Electroporation can introduce BSH into the cells very efficiently, and BSH stays in the cells and is not lost by washing. Therefore, if electroporation is applied to tumors after BSH injection, 10B remains in tumors but is cleared from normal tissues, and selective accumulation of 10B in tumors will be achieved after an adequate waiting time

  14. Self-shielding effects in neutron spectra measurements for neutron capture therapy by means of activation foils.

    Science.gov (United States)

    Pytel, Krzysztof; Józefowicz, Krystyna; Pytel, Beatrycze; Koziel, Alina

    2004-01-01

    The design and optimisation of a neutron beam for neutron capture therapy (NCT) is accompanied by the neutron spectra measurements at the target position. The method of activation detectors was applied for the neutron spectra measurements. Epithermal neutron energy region imposes the resonance structure of activation cross sections resulting in strong self-shielding effects. The neutron self-shielding correction factor was calculated using a simple analytical model of a single absorption event. Such a procedure has been applied to individual cross sections from pointwise ENDF/B-VI library and new corrected activation cross sections were introduced to a spectra unfolding algorithm. The method has been verified experimentally both for isotropic and for parallel neutron beams. Two sets of diluted and non-diluted activation foils covered with cadmium were irradiated in the neutron field. The comparison of activation rates of diluted and non-diluted foils has demonstrated the correctness of the applied self-shielding model.

  15. Carborane derivative development for boron neutron capture therapy. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Barnum, Beverly A.; Yan Hao; Moore, Roger; Hawthorne, M. Frederick; Baum, Kurt

    1999-04-01

    Boron Neutron Capture Therapy [BNCT] is a binary method of cancer therapy based on the capture of neutrons by a boron-10 atom [{sup 10}B]. Cytotoxic {sup 7}Li nuclei and {alpha}-particles are emitted, with a range in tissue of 9 and 5 {micro}m, respectively, about one cell diameter. The major obstacle to clinically viable BNCT is the selective localization of 5-30 ppm {sup 10}B in tumor cells required for effective therapy. A promising approach to BNCT is based on hydrophilic boron-rich oligomeric phosphate diesters, or ''trailers'' that have been shown to concentrate selectively in tumor tissue. Examples of these compounds were prepared previously at high cost using an automated DNA synthesizer. Direct synthesis methods are needed for the production of gram-scale quantities for further biological evaluation. The work accomplished as a result of the collaboration between Fluorochem, Inc. and UCLA demonstrates that short oligomers containing at least five carborane units with four phosphodiester linkages can be prepared in substantial quantities. This work was accomplished by the application of standard phosphoramidite coupling chemistry.

  16. Experimental verification of improved depth-dose distribution using hyper-thermal neutron incidence in neutron capture therapy.

    Science.gov (United States)

    Sakurai, Y; Kobayashi, T

    2001-01-01

    We have proposed the utilization of 'hyper-thermal neutrons' for neutron capture therapy (NCT) from the viewpoint of the improvement in the dose distribution in a human body. In order to verify the improved depth-dose distribution due to hyper-thermal neutron incidence, two experiments were carried out using a test-type hyper-thermal neutron generator at a thermal neutron irradiation field in Kyoto University Reactor (KUR), which is actually utilized for NCT clinical irradiation. From the free-in-air experiment for the spectrum-shift characteristics, it was confirmed that the hyper-thermal neutrons of approximately 860 K at maximum could be obtained by the generator. From the phantom experiment, the improvement effect and the controllability for the depth-dose distribution were confirmed. For example, it was found that the relative neutron depth-dose distribution was about 1 cm improved with the 860 K hyper-thermal neutron incidence, compared to the normal thermal neutron incidence.

  17. Boron neutron capture therapy; Radioterapia per cattura neutronica del boro

    Energy Technology Data Exchange (ETDEWEB)

    Mattioda, F. [Turin Politecnico, Turin (Italy); Merlone, A. [Pisa Univ., Pisa (Italy); Agosteo, S. [Milan Politecnico, Milan (Italy); Istituto Nazionale di Fisica Nucleare, Milan (Italy); Burn, K.W.; Tinti, R. [ENEA, Bologna (Italy). Dipt. energia; Capannesi, G.; Rosi, G. [ENEA, Casaccia (Italy). Dipt. innovazione; Casali, F.; Nava, E. [Bologna UNiv., Bologna (Italy); Gambarini, G. [Milan Univ., Milan (Italy)

    1999-08-01

    Boron radiotherapy in cancer treatment and the feasibility of using the Tapiro reactor as a neutron source is discussed. In particle, the article aims to focus attention on the possibility using ENEA's (National Agency for New Technology, Energy and the Environment) Tapiro reactor, appropriately modified, as a suitable neutron source for the experimental phase of boron neutron capture therapy in Italy. [Italian] Sono presentati gli studi sulla radioterapia per cattura neutronica del boro nella cura di alcune neoplasie e l'utilizzo del reattore Tapiro come sorgente di neutroni nel progetto italiano di ricerca condotto dall'ENEA.

  18. Selective thermal neutron capture therapy of cancer cells using their specific functional differentiation

    International Nuclear Information System (INIS)

    The theory and the history of selective thermal neutron capture therapy for malignant melanoma, thermal neutron capture therapy which has been developed by authors, synthesis and effects of 10B-compounds accumulating in melanoma cells and absorbing thermal neutron easily, and many experiments concerning this therapy were reviewed and discussed. (Tsunoda, M.)

  19. Physico-technical progress in neutron-capture therapy method

    International Nuclear Information System (INIS)

    This paper describes mainly development studies on the determination method of in vivo 10B for the purpose of employment for neutron capture therapy for malignant melanoma and other tumors. To darify the efficacy of the neutron capture therapy, it is necessary to determine 10B concentration in the diseased part. This study aimed at in vivo 10B concention determination in living sample to the level of ppm order with 10 % of analytical error within 1 hour, and these determination conditions were satified by prompt γ-ray (478 keV) determination of 10B (n, αγ)7Li reaction. This method required no sample pretreatment. Further, data normalization by γ-ray of H(n, γ)D reaction permitted no disturbance by sample shape or size. Lower limit of detection of the proposed method was estimated in terms of measuring time and statistical error by the equations of 10B concentration and error analysis derived by the authors. As for the effect of prompt γ-rays of 23Na(n, γ)24Na and 6Li(n, γ)7Li reactions, it was clarified that the former showed no disturbance but some correction was necessary in case of less than 0.1 g of smaple size owing to the latter reaction. In vivo sample determination showed the proposed method was practical. In this paper some results of phantom experiment for in vivo non-destructive 10B measurement and related simulation calculation, and examination of effect of (γ, n) reaction in heavy water of biomedical irradiation equipment on radiation quality were also described. (Takagi, S.)

  20. Boron Neutron Capture Therapy for Malignant Brain Tumors.

    Science.gov (United States)

    Miyatake, Shin-Ichi; Kawabata, Shinji; Hiramatsu, Ryo; Kuroiwa, Toshihiko; Suzuki, Minoru; Kondo, Natsuko; Ono, Koji

    2016-07-15

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting.

  1. Boron Neutron Capture Therapy for Malignant Brain Tumors

    Science.gov (United States)

    MIYATAKE, Shin-Ichi; KAWABATA, Shinji; HIRAMATSU, Ryo; KUROIWA, Toshihiko; SUZUKI, Minoru; KONDO, Natsuko; ONO, Koji

    2016-01-01

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting. PMID:27250576

  2. Boron Neutron Capture Therapy for Malignant Brain Tumors.

    Science.gov (United States)

    Miyatake, Shin-Ichi; Kawabata, Shinji; Hiramatsu, Ryo; Kuroiwa, Toshihiko; Suzuki, Minoru; Kondo, Natsuko; Ono, Koji

    2016-07-15

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Therefore, BNCT enables the application of a high dose of particle radiation selectively to tumor cells in which boron-10 compound has been accumulated. We applied BNCT using nuclear reactors for 167 cases of malignant brain tumors, including recurrent malignant gliomas, newly diagnosed malignant gliomas, and recurrent high-grade meningiomas from January 2002 to May 2014. Here, we review the principle and history of BNCT. In addition, we introduce fluoride-18-labeled boronophenylalanine positron emission tomography and the clinical results of BNCT for the above-mentioned malignant brain tumors. Finally, we discuss the recent development of accelerators producing epithermal neutron beams. This development could provide an alternative to the current use of specially modified nuclear reactors as a neutron source, and could allow BNCT to be performed in a hospital setting. PMID:27250576

  3. Cellular uptake and in vitro antitumor efficacy of composite liposomes for neutron capture therapy

    OpenAIRE

    Peters, Tanja; Grunewald, Catrin; Blaickner, Matthias; Ziegner, Markus; Schütz, Christian; Iffland, Dorothee; Hampel, Gabriele; Nawroth, Thomas; Langguth, Peter

    2015-01-01

    Background Neutron capture therapy for glioblastoma has focused mainly on the use of 10B as neutron capture isotope. However, 157Gd offers several advantages over boron, such as higher cross section for thermal neutrons and the possibility to perform magnetic resonance imaging during neutron irradiation, thereby combining therapy and diagnostics. We have developed different liposomal formulations of gadolinium-DTPA (Magnevist®) for application in neutron capture therapy of glioblastoma. The f...

  4. Boron neutron capture therapy for recurrent head and neck malignancies

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a tumor-cell targeted radiotherapy. When 10B absorbs thermal neutrons, the alpha and 7Li particles generated by the 10B (n, α) 7Li reaction are high linear energy transfer (LET) particles, and carry high kinetic energy (2.34 MeV), and have short ranges (4-9 micron-meters) of approximately one-cell diameter, resulting in a large relative biological effectiveness (RBE) and selective destruction of tumor cells containing 10B. We have, for the first time in the world, used BNCT to treat 11 patients with recurrent head and neck malignancies (HNM) after a standard primary therapy since 2001. The 11 patients were composed of 6 squamous cell carcinomas, 3 salivary gland tumors and 2 sarcomas. The results of BNCT were as follows. Regression rates (volume %) were complete response (CR): 2 cases, >90%: 5 cases, 73%: 1 case, 54%: 1 case, progressive disease (PD): 1 case, NE (not evaluated): 1 case. The response rate was 82%. Improvement of quality of life (QOL) was recognized, such as disappearance of tumor ulceration and covering with normal skin: relief of severe pain, bleeding, trismus and dyspnea: improvement of performance status (PS) (from 4 to 2) allowing the patients to return to work and elongate his survival period. Survival periods after BNCT were 1-38 months (mean: 8.5 months). The survival rate was 36% (4 cases). There are a few side-effects such as transient mucositis and alopecia less than Grade-2. These results indicate that BNCT represents a new and promising treatment approach even for a huge or far-advanced HNM. (author)

  5. Phase II clinical study of boron neutron capture therapy combined with X-ray radiotherapy/temozolomide in patients with newly diagnosed glioblastoma multiforme-Study design and current status report

    Energy Technology Data Exchange (ETDEWEB)

    Kawabata, Shinji, E-mail: neu046@poh.osaka-med.ac.jp [Department of Neurosurgery, Osaka Medical College, 2-7 Daigaku-Machi, Takatsuki, Osaka 569-8686 (Japan); Miyatake, Shin-Ichi; Hiramatsu, Ryo; Hirota, Yuki; Miyata, Shiro; Takekita, Yoko; Kuroiwa, Toshihiko [Department of Neurosurgery, Osaka Medical College, 2-7 Daigaku-Machi, Takatsuki, Osaka 569-8686 (Japan); Kirihata, Mitsunori [Graduate School of Life and Environmental Sciences, Osaka Prefecture University, 1-1 Gakuen-cho, Naka-ku, Sakai, Osaka 599-8931 (Japan); Sakurai, Yoshinori; Maruhashi, Akira; Ono, Koji [Kyoto University Research Reactor Institute, 2 Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka 590-0494 (Japan)

    2011-12-15

    Recently, we reported our clinical experiences of boron neutron capture therapy (BNCT) for the newly diagnosed glioblastoma. The major differences of our protocol from the other past studies were simultaneous use of both sodium borocapate and boronophenylalanine, and combination with fractionated X-ray irradiation. These results showed the efficacy of combination therapy with external beam X-ray irradiation and BNCT. For our future study, we planned the multi-centric phase II clinical study for newly diagnosed glioblastoma patients in Japan (OSAKA-TRIBRAIN0902, NCT00974987).

  6. Boron neutron capture therapy for recurrent head and neck malignancies

    International Nuclear Information System (INIS)

    To avoid severe impairment of oro-facial structures and functions, it is necessary to explore new treatments for recurrent head and neck malignancies (HNM). Boron neutron capture therapy (BNCT) is tumor-cell targeted radiotherapy that has significant superiority over conventional radiotherapies in principle. So far for 4 years and 3 months, we have treated with 37 times of BNCT for 21 patients (14 squamous cell carcinomas (SCC), 4 salivary gland carcinomas and 3 sarcomas) with a recurrent and far advanced HNM since 2001. Results are (1) 10B concentration of tumor/normal tissue ratio (T/N ratio) of FBPA-PET studies were SCC: 1.8-5.7, sarcoma: 2.5-4.0, parotid tumor: 2.5-3.7. (2) Therapeutic effects were CR: 6cases, PR: 11cases, PD: 3cases NE (not evaluated): 1case. Response rate was 81%. (3) Improvement of QOL such as a relief of severe pain, bleeding, and exudates at the local lesion, improvement of PS, disappearance of ulceration, covered with normal skin and preserved oral and maxillofacial functions and tissues. (4) Survival periods after BNCT were 1-51 months (mean: 9.8 months). 4-year survival rate was 39% by Kaplan-Meier analysis. (5) A few adverse-effects such as transient mucositis, alopecia were recognized. These results indicate that BNCT represents a new and promising treatment approach for advanced HNM. (author)

  7. Boron neutron capture therapy in cancer: past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Pisarev, Mario A.; Dagrosa, Maria Alejandra; Juvenal, Guilermo J. [National Atomic Energy Commission, Buenos Aires (Argentina). Div. of Nuclear Biochemistry; University of Buenos Aires (Argentina). School of Medicine. Dept. of Human Biochemistry

    2007-07-15

    Undifferentiated thyroid cancer (UTC) is a very aggressive tumor with no effective treatment, since it lacks iodine uptake and does not respond to radio or chemotherapy. The prognosis of these patients is bad, due to the rapid growth of the tumor and the early development of metastasis. Boron neutron capture therapy (BNCT) is based on the selective uptake of certain boron non-radioactive compounds by a tumor, and the subsequent irradiation of the area with an appropriate neutron beam. {sup 10}B is then activated to {sup 11}B, which will immediately decay releasing alpha particles and {sup 7}Li, of high linear energy transfer (LET) and limited reach. Clinical trials are being performed in patients with glioblastoma multiform and melanoma. We have explored its possible application to UTC. Our results demonstrated that a cell line of human UTC has a selective uptake of borophenylalanine (BPA) both in vitro and after transplantation to nude mice. Treatment of mice by BNCT led to a complete control of growth and cure of 100% of the animals. Moreover dogs with spontaneous UTC also have a selective uptake of BPA. At the present we are studying the biodistribution of BPA in patients with UTC before its application in humans. (author)

  8. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    Science.gov (United States)

    Herrera, María S.; González, Sara J.; Minsky, Daniel M.; Kreiner, Andrés J.

    2010-08-01

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

  9. Carboranyl Nucleosides & Oligonucleotides for Neutron Capture Therapy Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Schinazi, Raymond F.

    2004-12-01

    This proposal enabled us to synthesize and develop boron-rich nucleosides and oligonucleotide analogues for boron neutron capture therapy (BNCT) and the treatment of various malignancies. First, we determined the relationship between structure, cellular accumulation and tissue distribution of 5-o-carboranyl-2'-deoxyuridine (D-CDU) and its derivatives D-ribo-CU and 5-o-carboranyluracil (CU), to potentially target brain and other solid tumors for neutron capture therapy. Synthesized carborane containing nucleoside derivatives of CDU, D- and L-enantiomers of CDU, D-ribo-CU and CU were used. We measured tissue disposition in xenografted mice bearing 9479 human prostate tumors xenografts and in rats bearing 9L gliosarcoma isografts in their flanks and intracranially. The accumulation of D-CDU, 1-({beta}-L-arabinosyl)-5-o-carboranyluracil, D-ribo-CU, and CU were also studied in LnCap human prostate tumor cells and their retention was measured in male nude mice bearing LnCap and 9479 human prostate tumor xenografts. D-CDU, D-ribo-CU and CU levels were measured after administration in mice bearing 9479 human prostate tumors in their flanks. D-CDU achieved high cellular concentrations in LnCap cells and up to 2.5% of the total cellular compound was recovered in the 5'-monophosphorylated form. D-CDU cellular concentrations were similar in LnCap and 9479 tumor xenografts. Studies in tumor bearing animals indicated that increasing the number of hydroxyl moieties in the sugar constituent of the carboranyl nucleosides lead to increased rate and extent of renal elimination, a decrease in serum half-lives and an increased tissue specificity. Tumor/brain ratios were greatest for CDU and D-ribo-CU, while tumor/prostate ratios were greatest with CU. CDU and D-ribo-CU have potential for BNCT of brain malignancies, while CU may be further developed for prostate cancer. A method was developed for the solid phase synthesis of oligonucleotides containing (ocarboran-1-yl

  10. Carboranyl Oligonucleotides for Neutron Capture Therapy Final Report

    International Nuclear Information System (INIS)

    This proposal enabled us to synthesize and develop boron-rich nucleosides and oligonucleotide analogues for boron neutron capture therapy (BNCT) and the treatment of various malignancies. First, we determined the relationship between structure, cellular accumulation and tissue distribution of 5-o-carboranyl-2'-deoxyuridine (D-CDU) and its derivatives D-ribo-CU and 5-o-carboranyluracil (CU), to potentially target brain and other solid tumors for neutron capture therapy. Synthesized carborane containing nucleoside derivatives of CDU, D- and L-enantiomers of CDU, D-ribo-CU and CU were used. We measured tissue disposition in xenografted mice bearing 9479 human prostate tumors xenografts and in rats bearing 9L gliosarcoma isografts in their flanks and intracranially. The accumulation of D-CDU, 1-(β-L-arabinosyl)-5-o-carboranyluracil, D-ribo-CU, and CU were also studied in LnCap human prostate tumor cells and their retention was measured in male nude mice bearing LnCap and 9479 human prostate tumor xenografts. D-CDU, D-ribo-CU and CU levels were measured after administration in mice bearing 9479 human prostate tumors in their flanks. D-CDU achieved high cellular concentrations in LnCap cells and up to 2.5% of the total cellular compound was recovered in the 5'-monophosphorylated form. D-CDU cellular concentrations were similar in LnCap and 9479 tumor xenografts. Studies in tumor bearing animals indicated that increasing the number of hydroxyl moieties in the sugar constituent of the carboranyl nucleosides lead to increased rate and extent of renal elimination, a decrease in serum half-lives and an increased tissue specificity. Tumor/brain ratios were greatest for CDU and D-ribo-CU, while tumor/prostate ratios were greatest with CU. CDU and D-ribo-CU have potential for BNCT of brain malignancies, while CU may be further developed for prostate cancer. A method was developed for the solid phase synthesis of oligonucleotides containing (ocarboran-1-yl

  11. A suggestion for B-10 imaging during boron neutron capture therapy

    OpenAIRE

    Cortesi, M.

    2007-01-01

    Selective accumulation of B-10 compound in tumour tissue is a fundamental condition for the achievement of BNCT (Boron Neutron Capture Therapy), since the effectiveness of therapy irradiation derives just from neutron capture reaction of B-10. Hence, the determination of the B-10 concentration ratio, between tumour and healthy tissue, and a control of this ratio, during the therapy, are essential to optimise the effectiveness of the BNCT, which it is known to be based on the selective uptake ...

  12. NCT program at Nuclear Medicine, Inc

    International Nuclear Information System (INIS)

    The Neutron Capture Therapy program at Nuclear Medicine, Inc. (NMI) is focused on obtaining Food and Drug Administration (FDA) approval of the treatment for malignant brain tumors. To minimize both the time and expense of the approval process, research efforts have been strictly focused and Orphan Drug sponsorship of the boron compound, Na2B12H11SH, has been obtained. The significance of Orphan Drug sponsorship and NMI's initial meeting with the FDA to discuss preclinical and clinical protocols are discussed. 9 references, 2 figures

  13. Isodose Curves and Treatment Planning for Boron Neutron Capture Therapy.

    Science.gov (United States)

    Liu, Hungyuan B.

    The development of Boron Neutron Capture Therapy (BNCT) has been progressing in both ^{10 }B compound development and testing and neutron beam delivery. Animal tests are now in progress with several ^{10}B compounds and once the results of these animal tests are promising, patient trials can be initiated. The objective of this study is to create a treatment planning method based on the dose calculations by a Monte Carlo code of a mixed radiation field to provide linkage between phantom dosimetry and patient irradiation. The research started with an overall review of the development of BNCT. Three epithermal neutron facilities are described, including the operating Brookhaven Medical Research Reactor (BMRR) beam, the designed Missouri University Research Reactor (MURR) beam, and a designed accelerator based neutron source. The flux and dose distributions in a head model have been calculated for irradiation by these neutron beams. Different beam parameters were inter -compared for effectiveness. Dosimetric measurements in an elliptical lucite phantom and a cylindrical water phantom were made and compared to the MCNP calculations for irradiation by the BMRR beam. Repeated measurements were made and show consistent. To improve the statistical results calculated by MCNP, a neutron source plane was designed to start neutrons at the BMRR irradiation port. The source plane was used with the phantoms for dosimetric calculations. After being verified by different phantom dosimetry and in-air flux measurements at the irradiation port, the source plane was used to calculate the flux and dose distributions in the head model. A treatment planning program was created for use on a PC which uses the MCNP calculated results as input. This program calculates the thermal neutron flux and dose distributions of each component of radiation in the central coronal section of the head model for irradiation by a neutron beam. Different combinations of head orientations and irradiation

  14. Design and preparation of gadolinium-reservoir microcapsules for neutron-capture therapy by means of the Wurster process.

    Science.gov (United States)

    Miyamoto, M; Ichikawa, H; Fukumori, Y; Akine, Y; Tokuuye, K

    1997-12-01

    Gadolinium (Gd)-containing microcapsules designed for neutron-capture therapy (NCT) were prepared by a spouted bed coating process. Microcapsules were designed as a Gd-reservoir. They were prepared with the following properties: particle size was smaller than 50 microns, Gd-content was as high as possible, and release of Gd was suppressed as long as possible. Calcium carbonate (20-32 microns) was selected as a speed particle. As a Gd-source, gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) or a synthesized water-insoluble Gd-DTPA derivative, Gd-DTPA-distearylamide (Gd-DTPA-SA), was layered onto the seed particles. The release-suppressing layer was composed of aqueous acrylic latex of 9:9:4 poly(ethyl acrylate/methyl methacrylate/2-hydroxyethyl methacrylate). In preliminary studies, Gd-DTPA microcapsules with 41-45 microns (mass median diameter) were prepared; they released Gd with a short lag-time and 3h-prolongation. Complete release suppression was, however, difficult to achieve because of high water-solubility of Gd-DTPA. Hence, a hydrophobic derivative, Gd-DTPA-SA, was next used as a Gd source. Gd-DTPA-SA microcapsules could be prepared with a mass median diameter of 52 microns. Gd-DTPA-SA content of the microcapsules was 38% and release of Gd was suppressed to less than 0.2% over 60 d. PMID:9433776

  15. NCT and Culture-Conscious Developmental Science

    Science.gov (United States)

    Downing-Wilson, Deborah; Pelaprat, Etienne; Rosero, Ivan; Vadeboncoeur, Jennifer; Packer, Martin; Cole, Michael

    2013-01-01

    The authors share the belief that there is great potential for developmental science in bringing the ideas of Niche Construction Theory (NCT), as developed in evolutionary biology, into conversation with Vygotskian-inspired theories such as cultural-historical and activity theories, distributed cognition, and embodied cognition, although from…

  16. Synthesis and characterization of gadolinium nanostructured materials with potential applications in magnetic resonance imaging, neutron-capture therapy and targeted drug delivery

    Energy Technology Data Exchange (ETDEWEB)

    Stefanakis, Dimitrios; Ghanotakis, Demetrios F., E-mail: ghanotakis@chemistry.uoc.g [University of Crete, Department of Chemistry (Greece)

    2010-05-15

    Two Gadolinium nanostructured materials, Gd{sub 2}(OH){sub 5}NO{sub 3} nanoparticles and Gd(OH){sub 3} nanorods, were synthesized and extensively characterized by various techniques. In addition to the potential use of Gd{sub 2}(OH){sub 5}NO{sub 3} in magnetic resonance imaging (MRI) and Neutron-capture therapy (NCT) application, it could also be used in targeted drug delivery. An antibiotic (nalidixic acid), two amino acids (aspartic and glutamic acid), a fatty acid and a surfactant (SDS) were intercalated in the nanoparticles. The surface of the nanoparticles was modified with folic acid in order to be capable of targeted delivery to folate receptor expressing sites, such as tumor human cells.

  17. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC): application for photodynamic therapy and boron neutron capture therapy.

    Science.gov (United States)

    Hiramatsu, Ryo; Kawabata, Shinji; Tanaka, Hiroki; Sakurai, Yoshinori; Suzuki, Minoru; Ono, Koji; Miyatake, Shin-ichi; Kuroiwa, Toshihiko; Hao, Erhong; Vicente, M Graça H

    2015-03-01

    Carboranyl-containing chlorins have emerged as promising dual sensitizers for use in both photodynamic therapy (PDT) and boron neutron capture therapy (BNCT), by virtue of their known tumor affinity, low cytotoxicity in dark conditions, and their strong absorptions in the red region of the optical spectrum. Tetrakis(p-carboranylthio-tetrafluorophenyl)chlorin (TPFC) is a new synthetic carboranyl-containing chlorin of high boron content (24% by weight). To evaluate TPFC's applicability as sensitizer for both PDT and BNCT, we performed an in vitro and in vivo study using F98 rat glioma cells and F98 rat glioma-bearing brain tumor models. For the in vivo BNCT study, we used boronophenylalanine (BPA), which is currently used in clinical BNCT studies, via intravenous administration (i.v.) and/or used TPFC via convection-enhanced delivery (CED), a method for local drug infusion directly into the brain. In the in vitro PDT study, the cell surviving fraction following laser irradiation (9 J/cm(2) ) was 0.035 whereas in the in vitro BNCT study, the cell surviving fraction following neutron irradiation (thermal neutron = 1.73 × 10(12) n/cm(2) ) was 0.04. In the in vivo BNCT study, the median survival time following concomitant administration of BPA (i.v.) and TPFC (CED) was 42 days (95% confidence interval; 37-43 days).

  18. A microdosimetric study of {sup 10}B(n,{alpha}){sup 7}Li and {sup 157}Gd(n,{gamma}) reactions for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, C.K.C.; Sutton, M.; Evans, T.M. [Georgia Inst. of Tech., Atlanta, GA (United States); Laster, B.H. [Brookhaven National Lab., Upton, NY (United States). Medical Dept.

    1999-01-01

    This paper presents the microdosimetric analysis for the most interesting cell survival experiment recently performed at the Brookhaven National Laboratory (BNL). In this experiment, the cells were first treated with a gadolinium (Gd) labeled tumor-seeking boronated porphyrin (Gd-BOPP) or with BOPP alone, and then irradiated with thermal neutrons. The resulting cell-survival curves indicate that the {sup 157}Gd(n,{gamma}) reactions are very effective in cell killing. The death of a cell treated with Gd-BOPP was attributed to either the {sup 10}B(n,{alpha}){sup 7}Li reactions or the {sup 157}Gd(n,{gamma}) reactions (or both). However, the quantitative relationship between the two types of reaction and the cell-survival fraction was not clear. This paper presents the microdosimetric analysis for the BNL experiment based on the measured experimental parameters, and the results clearly suggest a quantitative relationship between the two types of reaction and the cell survival fraction. The results also suggest new research in gadolinium neutron capture therapy (GdNCT) which may lead to a more practical modality than the boron neutron capture therapy (BNCT) for treating cancers.

  19. Gadolinium as an element for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, R.M.; Liu, H.B.; Laster, B.H.; Gordon, C.R.; Greenberg, D.D.; Warkentien, L.S.

    1992-01-01

    At BNL, preparations are being made to test in vitro compounds containing Gd and compare their response to the response of GD-DTPA to determine if one or several compounds can be located that enter the cells and enhance the Auger effect. Two similar rotators with positions for cell vials that have been constructed for these tests. The first rotator is made of only paraffin which simulates healthy tissue and provides control curves. The second rotator has 135 ppM of Gd-157 in the paraffin to simulate a Gd loaded tumor. Cells are irradiated in vials in the paraffin rotator and in the Gd-paraffin rotator at the epithermal beam of the Brookhaven Medical Research Reactor (BMRR). This produces an irradiation similar to what a patient would receive In an actual treatment. A combination of irradiations are made with both rotators; with no Gd compound or IdUrd In the cell media, with only Gd compound in the cell media and with both Gd compound and IdUrd in the cell media. The first set shows the effects of gamma rays from the H(n,gamma) reaction and the prompt gamma rays from capture of neutrons by Gd. The second set shows if there is any effect of Gd being in the cell media or inside the cells, i.e., an Auger effect. The third set shows the effect of enhancement by the IdUrd produced by the gamma rays from neutrons captured by either H or Gd. The fourth set combines all of the reactions and enhancements. Preliminary calculations and physical measurements of the doses that the cells will receive In these rotators have been made.

  20. Gadolinium as an element for neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, R.M.; Liu, H.B.; Laster, B.H.; Gordon, C.R.; Greenberg, D.D.; Warkentien, L.S.

    1992-12-31

    At BNL, preparations are being made to test in vitro compounds containing Gd and compare their response to the response of GD-DTPA to determine if one or several compounds can be located that enter the cells and enhance the Auger effect. Two similar rotators with positions for cell vials that have been constructed for these tests. The first rotator is made of only paraffin which simulates healthy tissue and provides control curves. The second rotator has 135 ppM of Gd-157 in the paraffin to simulate a Gd loaded tumor. Cells are irradiated in vials in the paraffin rotator and in the Gd-paraffin rotator at the epithermal beam of the Brookhaven Medical Research Reactor (BMRR). This produces an irradiation similar to what a patient would receive In an actual treatment. A combination of irradiations are made with both rotators; with no Gd compound or IdUrd In the cell media, with only Gd compound in the cell media and with both Gd compound and IdUrd in the cell media. The first set shows the effects of gamma rays from the H(n,gamma) reaction and the prompt gamma rays from capture of neutrons by Gd. The second set shows if there is any effect of Gd being in the cell media or inside the cells, i.e., an Auger effect. The third set shows the effect of enhancement by the IdUrd produced by the gamma rays from neutrons captured by either H or Gd. The fourth set combines all of the reactions and enhancements. Preliminary calculations and physical measurements of the doses that the cells will receive In these rotators have been made.

  1. Medical aspects of boron-slow neutron capture therapy

    International Nuclear Information System (INIS)

    Earlier radiations of patients with cerebral tumors disclosed the need: (1) to find a carrier of the boron compound which would leave the blood and concentrate in the tumor, (2) to use a more penetrating neutron beam, and (3) to develop a much faster method for assaying boron in blood and tissue. To some extent number1 has been accomplished in the form of Na2 B12 H11 SH, number2 has yet to be achieved, and number3 has been solved by the measurement of the 478-keV gamma ray when the 10B atom disintegrates following its capture of a slow neutron. The hitherto unreported data in this paper describe through the courtesy of Professor Hiroshi Hatanaka his studies on the pharmacokinetics and quality control of Na2 B12 H11SH based on 96 boron infusions in 86 patients. Simultaneous blood and tumor data are plotted here for 30 patients with glioblastomas (Grade III-IV gliomas), illustrating remarkable variability. Detailed autopsy findings on 18 patients with BNCT showed radiation injury in only 1. Clinical results in 12 of the most favorably situated glioblastomas reveal that 5 are still alive with a 5-year survival rate of 58% and the excellent Karnofsky performance rating of 87%. For the first time evidence is presented that slow-growing astrocytomas may benefit from BNCT. 10 references, 8 figures, 5 tables

  2. A colorimetric determination of boron in biological sample for boron neutron capture therapy (BNCT)

    International Nuclear Information System (INIS)

    The boron neutron capture therapy (BNCT) has shown better prognosis in the treatment of glyemas and gluoblastomas grade III and IV than other therapies. During the treatment the levels of Na210B12H11SH must be known in several compartiments of the organism and with this purpose the method of colorimetric determination of boron using curcumine was established. This method is simple, reprodutible and adequate sensitivity for this control. (author)

  3. Automated bolus advisor control and usability study (ABACUS: does use of an insulin bolus advisor improve glycaemic control in patients failing multiple daily insulin injection (MDI therapy? [NCT01460446

    Directory of Open Access Journals (Sweden)

    Cavan David A

    2012-10-01

    manage their diabetes more effectively and minimise the risk of long-term diabetes related complications. Findings from a recent study suggest that BA use positively addresses both safety and lifestyle concerns; however, randomised trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes. Our study is designed to make these assessments. Trial registration NCT01460446

  4. Proceedings of workshop on 'boron science and boron neutron capture therapy'

    Energy Technology Data Exchange (ETDEWEB)

    Kitaoka, Y. [ed.

    1998-12-01

    This volume contains the abstracts and programs of the 8th (1996), 9th (1997) and 10th (1998) of the workshop on 'the Boron Science and Boron Neutron Capture Therapy' and the recent progress reports especially subscribed. The 11 of the presented papers are indexed individually. (J.P.N.)

  5. Further development of thermal neutron capture therapy for metastatic and deeply-invasive human malignant melanoma

    International Nuclear Information System (INIS)

    This issue is the collection of the papers presented thermal neutron capture therapy for metastatic and deeply-invasive human malignant melanoma. Separate abstracts were prepared for 2 of the papers in this report. The remaining 32 papers were considered outside the subject scope of INIS. (J.P.N.)

  6. To gadolinium using for neutron capture therapy researches at WWR-SM reactor

    International Nuclear Information System (INIS)

    The analysis of using gadolinium (isotope and natural) for the medical purposes in neutron-capture therapy of cancer diseases is carried out. Results of definition of the epithermal neutron beam irradiation dose for biological objects with gadolinium-containing preparations are presented by using the WWR-SM reactor. (authors)

  7. The Boron Neutron Capture Therapy (BNCT) Project at the TRIGA Reactor in Mainz, Germany

    DEFF Research Database (Denmark)

    Hampel, G.; Grunewald, C.; Schütz, C.;

    2011-01-01

    The thermal column of the TRIGA reactor in Mainz is being used very effectively for medical and biological applications. The BNCT (boron neutron capture therapy) project at the University of Mainz is focussed on the treatment of liver tumours, similar to the work performed at Pavia (Italy) a few...

  8. Implications for clinical treatment from the micrometer site dosimetric calculations in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, Trent L. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37901 (United States)], E-mail: tnichol2@utk.edu; Kabalka, George W. [Department of Chemistry, University of Tennessee, Knoxville, TN 37901 (United States); Miller, Laurence F. [Department of Nuclear and Radiological Engineering, University of Tennessee, Knoxville, TN 37901 (United States); McCormack, Michael T. [Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN 37920 (United States); Johnson, Andrew [Rush University Medical Center, Chicago, IL 60612 (United States)

    2009-07-15

    Boron neutron capture therapy has now been used for several malignancies. Most clinical trials have addressed its use for the treatment of glioblastoma multiforme. A few trials have focused on the treatment of malignant melanoma with brain metastases. Trial results for the treatment of glioblastoma multiforme have been encouraging, but have not achieved the success anticipated. Results of trials for the treatment of malignant melanoma have been very promising, though with too few patients for conclusions to be drawn. Subsequent to these trials, regimens for undifferentiated thyroid carcinoma, hepatic metastases from adenocarcinoma of the colon, and head and neck malignancies have been developed. These tumors have also responded well to boron neutron capture therapy. Glioblastoma is an infiltrative tumor with distant individual tumor cells that might create a mechanism for therapeutic failure though recurrences are often local. The microdosimetry of boron neutron capture therapy can provide an explanation for this observation. Codes written to examine the micrometer scale energy deposition in boron neutron capture therapy have been used to explore the effects of near neighbor cells. Near neighbor cells can contribute a significantly increased dose depending on the geometric relationships. Different geometries demonstrate that tumors which grow by direct extension have a greater near neighbor effect, whereas infiltrative tumors lose this near neighbor dose which can be a significant decrease in dose to the cells that do not achieve optimal boron loading. This understanding helps to explain prior trial results and implies that tumors with small, closely packed cells that grow by direct extension will be the most amenable to boron neutron capture therapy.

  9. Boron nanoparticles inhibit turnour growth by boron neutron capture therapy in the murine B16-OVA model

    DEFF Research Database (Denmark)

    Petersen, Mikkel Steen; Petersen, Charlotte Christie; Agger, Ralf;

    2008-01-01

    Background: Boron neutron capture therapy usually relies on soluble, rather than particulate, boron compounds. This study evaluated the use of a novel boron nanoparticle for boron neutron capture therapy. Materials and Methods: Two hundred and fifty thousand B16-OVA tumour cells, pre...

  10. Semiempirical theory of 10B NCT

    International Nuclear Information System (INIS)

    Theory is based upon the characteristic of spatial distribution of slow neutrons in irradiated object named the effective mass. Effective mass can be measured in experiments with liquid phantom, target for slow neutrons field measurements and prompt gamma-ray spectrometer. Mathematical apparatus of this theory is a number of algebraic equations with evident physical sense. These equations set connection between atomic and nuclear data characterizing dose forming reactions and their products, achieved preparations concentrations, geometrical, spectral and dose characteristics of therapeutic neutron beams. Theory allows calculation of following values as a function of preparations concentrations: partial contents of nuclear reactions and adsorbed dose; mean number of nuclear reactions in one cell, depending on its size, in the maximum of slow neutrons spatial distribution; spectral and dose characteristics of therapeutic beams, depending on their sizes; neutron flux densities, depending upon desired absorbed dose in the maximum of spatial distribution. Calculation and measurement results are given on therapeutic neutron beam for 10B NCT, formed by thin hydrogen scatterer set in horizontal experimental channel IR-8 RRC 'Kurchatov institute' beside the reactor core. (author)

  11. Formulation and preliminary evaluation of delivery vehicles for the boron neutron capture therapy of cancer

    OpenAIRE

    Olusanya, Temidayo; Stich, Theresia; Higgins, Samantha Caroline; Lloyd, Rhiannon Eleanor Iris; Smith, James Richard; Fatouros, Dimitrios; Calabrese, Gianpiero; Pilkington, Geoffrey John; Tsibouklis, John

    2015-01-01

    Boron neutron capture therapy (BNCT) is a method for selectively destroying malignant (normally glioma) cells whilst sparing normal tissue1. Irradiation of 10B (large neutron capture cross-section) with thermal neutrons effects the nuclear fission reaction: 10B + 1n → → 7Li+ + α + γ; where the penetration of α-particles and 7Li+ is only 8 and 5 µm, respectively, i.e., within a single cell thickness, assuming 10B can be preferentially located within glioma cells2. Poor selectivity is the main ...

  12. Formulation and preliminary evaluation of delivery vehicles for the boron neutron capture therapy of cancer

    OpenAIRE

    Olusanya, Temidayo Olajumoke Bolanle

    2015-01-01

    Boron neutron capture therapy (BNCT) is a method for selectively destroying malignant (normally glioma) cells whilst sparing normal tissue. Irradiation of 10B (large neutron capture cross-section) with thermal neutrons effects the nuclear fission reaction: 10B + 1n → → 7Li+ + α + γ; where the penetration of -particles and 7Li+ is only 8 and 5 μm, respectively, i.e., within a single cell thickness, assuming 10B can be preferentially located within glioma cells. Poor selectivity is the main r...

  13. Cellular uptake and in vitro antitumor efficacy of composite liposomes for neutron capture therapy

    International Nuclear Information System (INIS)

    Neutron capture therapy for glioblastoma has focused mainly on the use of 10B as neutron capture isotope. However, 157Gd offers several advantages over boron, such as higher cross section for thermal neutrons and the possibility to perform magnetic resonance imaging during neutron irradiation, thereby combining therapy and diagnostics. We have developed different liposomal formulations of gadolinium-DTPA (Magnevist®) for application in neutron capture therapy of glioblastoma. The formulations were characterized physicochemically and tested in vitro in a glioma cell model for their effectiveness. Liposomes entrapping gadolinium-DTPA as neutron capture agent were manufactured via lipid/film-extrusion method and characterized with regard to size, entrapment efficiency and in vitro release. For neutron irradiation, F98 and LN229 glioma cells were incubated with the newly developed liposomes and subsequently irradiated at the thermal column of the TRIGA reactor in Mainz. The dose rate derived from neutron irradiation with 157Gd as neutron capturing agent was calculated via Monte Carlo simulations and set in relation to the respective cell survival. The liposomal Gd-DTPA reduced cell survival of F98 and LN229 cells significantly. Differences in liposomal composition of the formulations led to distinctly different outcome in cell survival. The amount of cellular Gd was not at all times proportional to cell survival, indicating that intracellular deposition of formulated Gd has a major influence on cell survival. The majority of the dose contribution arises from photon cross irradiation compared to a very small Gd-related dose. Liposomal gadolinium formulations represent a promising approach for neutron capture therapy of glioblastoma cells. The liposome composition determines the uptake and the survival of cells following radiation, presumably due to different uptake pathways of liposomes and intracellular deposition of gadolinium-DTPA. Due to the small range of the

  14. Initiation of a phase-I trial of neutron capture therapy at the MIT research reactor

    International Nuclear Information System (INIS)

    The Massachusetts Institute of Technology (MIT), the New England Medical Center (NEMC), and Boston University Medical Center (BUMC) initiated a phase-1 trial of boron neutron capture therapy (BNCT) on September 6, 1994, at the 5-MW(thermal) MIT research reactor (MITR). A novel form of experimental cancer therapy, BNCT is being developed for certain types of highly malignant brain tumors such as glioblastoma and melanoma. The results of the phase-1 trials on patients with tumors in the legs or feet are described

  15. Power Burst Facility/Boron Neutron Capture Therapy Program for cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, A.L. (ed.); Dorn, R.V. III.

    1990-08-01

    This report discusses monthly progress in the Power Boron Facility/Boron Neutron Capture Therapy (PBF/BNCT) Program for Cancer Treatment. Highlights of the PBF/BNCT Program during August 1990 include progress within the areas of: Gross Boron Analysis in Tissue, Blood, and Urine, boron microscopic (subcellular) analytical development, noninvasive boron quantitative determination, analytical radiation transport and interaction modeling for BNCT, large animal model studies, neutron source and facility preparation, administration and common support and PBF operations.

  16. Boron neutron capture therapy for oral precancer: proof of principle in an experimental animal model

    Energy Technology Data Exchange (ETDEWEB)

    A. Monti Hughes; ECC Pozzi; S. Thorp; M. A. Garabalino; R. O. Farias; S. J. Gonzalez; E. M. Heber; M. E. Itoiz; R. F. Aromando; A. J. Molinari; M. Miller; D. W. Nigg; P. Curotto; V. A. Trivillin; A. E. Schwint

    2013-11-01

    Field-cancerized tissue can give rise to second primary tumours, causing therapeutic failure. Boron neutron capture therapy (BNCT) is based on biological targeting and would serve to treat undetectable foci of malignant transformation. The aim of this study was to optimize BNCT for the integral treatment for oral cancer, with particular emphasis on the inhibitory effect on tumour development originating in precancerous conditions, and radiotoxicity of different BNCT protocols in a hamster cheek pouch oral precancer model.

  17. SBNCT plan: A 3-dimensional treatment planning system for boron neutron capture therapy

    International Nuclear Information System (INIS)

    The need for accurate and comprehensive 3-dimensional treatment planning for boron neutron capture therapy (BNCT) has been debated for the past several years. Although many argue against the need for elaborate and expensive treatment planning programs which mimic conventional radiotherapy planning systems, it is clear that in order to realize significant gains over conventional fractionated radiation therapy, patients must be treated to the edge of normal tissue tolerance. Just how close to this edge is dictated by the uncertainties in dosimetry. Hence the focus of BNCT planning is the determination of dose distribution throughout normal tissue volumes. Although precise geometric manipulation of the epithermal neutron beam is not achievable, the following variables play an important role in BNCT optimization: patient orientation, dose fractionation, number of fields, megawatt-minutes per fraction, use of surface bolus, and use of collimation. Other variables which are not as easily adjustable and would not, therefore, be part of treatment planning optimization, include external patient contour, internal patient heterogeneities, boron compound distributions, and RBE's. The boron neutron capture therapy planning system developed at SUNY Stony Brook (SBNCT-Plan) was designed as an interactive graphic tool to assist the radiation oncologist in generating the optimum plan for a neutron capture treatment

  18. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise

    International Nuclear Information System (INIS)

    Over the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, because of their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The main factor preventing this new technology from realizing its full potential in commercial applications is the maximization of signal coupling efficiency and the minimization of noise capture. A principal constituent of noise is Cerenkov radiation. This study reports the calculated capture of Cerenkov radiation by an optical fibre in the special case where the radiation is generated by a relativistic particle on the fibre axis and the fibre axis is parallel to the Cerenkov cone. The fraction of radiation captured is calculated as a function of the fibre core refractive index and the refractive index difference between the core and the cladding of the fibre for relativistic particles. This is then used to deduce the relative intensity captured for a range of fibre core refractive indices and fibre core-cladding refractive index differences. It is shown that the core refractive index has little effect on the amount of radiation captured compared to the refractive index difference. The implications of this result for the design of radiation therapy plastic scintillation dosimeters are considered

  19. Design of a boron neutron capture enhanced fast neutron therapy assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhonglu

    2006-08-01

    The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator near the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm{sup 2} treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm{sup 2} collimation was 21.9% per 100-ppm {sup 10}B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about 48.5% and 27.9% of the dose rate of the standard 10x10 cm{sup 2} fast neutron treatment beam. To validate the design calculations, a simplified BNCEFNT assembly was built using four lead bricks to form a 5x5 cm{sup 2} collimator. Five 1.0-cm thick 20x20 cm{sup 2} tungsten plates were used to obtain different filter thicknesses and graphite bricks/blocks were used to form a reflector. Measurements of the dose enhancement of the simplified assembly in a water-filled head phantom were performed using a pair of tissue-equivalent ion chambers. One of the ion chambers is loaded with 1000-ppm natural boron (184-ppm {sup 10}B) to measure dose due to boron neutron capture. The measured dose enhancement at 5.0-cm depth

  20. Design of a boron neutron capture enhanced fast neutron therapy assembly

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhonglu [Georgia Inst. of Technology, Atlanta, GA (United States)

    2006-12-01

    The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator near the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm2 treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm2 collimation was 21.9% per 100-ppm 10B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about 48.5% and 27.9% of the dose rate of the standard 10x10 cm2 fast neutron treatment beam. To validate the design calculations, a simplified BNCEFNT assembly was built using four lead bricks to form a 5x5 cm2 collimator. Five 1.0-cm thick 20x20 cm2 tungsten plates were used to obtain different filter thicknesses and graphite bricks/blocks were used to form a reflector. Measurements of the dose enhancement of the simplified assembly in a water-filled head phantom were performed using a pair of tissue-equivalent ion chambers. One of the ion chambers is loaded with 1000-ppm natural boron (184-ppm 10B) to measure dose due to boron neutron capture. The

  1. A suggestion for B-10 imaging during boron neutron capture therapy

    CERN Document Server

    Cortesi, M

    2007-01-01

    Selective accumulation of B-10 compound in tumour tissue is a fundamental condition for the achievement of BNCT (Boron Neutron Capture Therapy), since the effectiveness of therapy irradiation derives just from neutron capture reaction of B-10. Hence, the determination of the B-10 concentration ratio, between tumour and healthy tissue, and a control of this ratio, during the therapy, are essential to optimise the effectiveness of the BNCT, which it is known to be based on the selective uptake of B-10 compound. In this work, experimental methods are proposed and evaluated for the determination in vivo of B-10 compound in biological samples, in particular based on neutron radiography and gammaray spectroscopy by telescopic system. Measures and Monte Carlo calculations have been performed to investigate the possibility of executing imaging of the 10B distribution, both by radiography with thermal neutrons, using 6LiF/ZnS:Ag scintillator screen and a CCD camera, and by spectroscopy, based on the revelation of gamm...

  2. Boron neutron capture therapy of malignant brain tumors at the Brookhaven Medical Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Joel, D.D.; Coderre, J.A.; Chanana, A.D. [Brookhaven National Lab., Upton, NY (United States). Medical Dept.

    1996-12-31

    Boron neutron capture therapy (BNCT) is a bimodal form of radiation therapy for cancer. The first component of this treatment is the preferential localization of the stable isotope {sup 10}B in tumor cells by targeting with boronated compounds. The tumor and surrounding tissue is then irradiated with a neutron beam resulting in thermal neutron/{sup 10}B reactions ({sup 10}B(n,{alpha}){sup 7}Li) resulting in the production of localized high LET radiation from alpha and {sup 7}Li particles. These products of the neutron capture reaction are very damaging to cells, but of short range so that the majority of the ionizing energy released is microscopically confined to the vicinity of the boron-containing compound. In principal it should be possible with BNCT to selectively destroy small nests or even single cancer cells located within normal tissue. It follows that the major improvements in this form of radiation therapy are going to come largely from the development of boron compounds with greater tumor selectivity, although there will certainly be advances made in neutron beam quality as well as the possible development of alternative sources of neutron beams, particularly accelerator-based epithermal neutron beams.

  3. Synthesis and biological evaluation of boronated polyglycerol dendrimers as potential agent for neutron capture therapy

    International Nuclear Information System (INIS)

    In this work, the polyglycerol dendrimer (PGLD) generation 5 was used to obtain a boronated macromolecule for boron neutron capture therapy. The PGLD dendrimer was synthesized by the ring opening polymerization of deprotonated glycidol using polyglycerol as core functionality in a step-growth processes denominated divergent synthesis. The PGLD dendritic structure was confirmed by gel permeation chromatography, nuclear magnetic resonance (1H-NMR, 13C-NMR) and matrix assisted laser desorption/ionization techniques. The synthesized dendrimer presented low dispersion in molecular weights (Mw/Mn = 1.05) and a degree of branching of 0.82, which characterize the polymer dendritic structure. Quantitative neutron capture radiography was used to investigate the boron-10 enrichment of the polyglycerol dendrimer. The in vitro cytotoxicity to Chinese hamster ovary cells of 10B-PGLD dendrimer indicate lower cytotoxicity, suggesting that the macromolecule is a biocompatible material. (author)

  4. Early clinical experience of boron neutron capture therapy for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a binary treatment modality that can selectively irradiate tumor tissue. BNCT uses drugs containing a stable isotope of boron. 10B, to sensitize tumor cells to irradiation by low energy (thermal) neutrons. The interaction of the 10B with a thermal neutron (neutron capture) causes the 10B nucleus to split, releasing an alpha particle and a lithium nucleus. These products of the 10B(n, α)7Li reaction are very damaging to cells but have a combined path length in tissue of approximately 14 μm, or roughly the diameter of one or two cells. Thus, most of the ionizing energy imparted to tissue is localized to 10B-loaded cells

  5. Single photon image from position emission tomography with insertable collimator for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joo Young; Yoo, Do Kun; Suh, Tae Suk [Dept. of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of); Hong, Key Jo [Molecular Imaging Program at Stanford (MIPS), Dept. of Radiology, Stanford University, Stanford (United States)

    2014-04-15

    The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the boron neutron capture therapy (BNCT). The BNCT theory and conceptual diagram of our proposed system are shown fig.1. Data from the PET module, neutron source, and collimator was entered in the Monte Carlon-particle extende source code. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector.

  6. Boron neutron capture therapy for advanced and/or recurrent cancers in the oral cavity

    International Nuclear Information System (INIS)

    This preliminary study of 5 patients with advanced and/or recurrent cancer in the oral cavity was performed to evaluate the effectiveness of Boron Neutron Capture Therapy (BNCT). The patients received therapy with the 10B-carrier p-boronophenylalanine (BPA) with or without borocaptate sodium (BSH) and irradiation thereafter with epithermal neutrons. All underwent 18F-BPA PET studies before receiving BNCT to determine the accumulation ratios of BPA in tumor and normal tissues. The tumor mass was decreased in size and at minimum a transient partial response was achieved in all cases, though rapid tumor re-growth was observed in 2. Although tentative clinical responses and improvements in quality of life were recognized, obliteration of the tumor was not obtained in any of the cases. Additional studies are required to determine the utility and indication of BNCT for oral cancer. (author)

  7. Study of characteristics for heavy water photoneutron source in boron neutron capture therapy

    CERN Document Server

    Salehi, Danial; Sardari, Dariush

    2013-01-01

    Bremsstrahlung photon beams produced by medical linear accelerators are currently the most commonly used method of radiation therapy for cancerous tumors. Photons with energies greater than 8-10 MeV potentially generate neutrons through photonuclear interactions in the accelerator's treatment head, patient's body, and treatment room ambient. Electrons impinging on a heavy target generate a cascade shower of bremsstrahlung photons, the energy spectrum of which shows an end point equal to the electron beam energy. By varying the target thickness, an optimum thickness exists for which, at the given electron energy, maximum photon flux is achievable. If a source of high-energy photons i.e. bremsstrahlung, is conveniently directed to a suitable D2O target, a novel approach for production of an acceptable flux of filterable photoneturons for boron neutron capture therapy (BNCT) application is possible. This study consists of two parts. 1. Comparison and assessment of deuterium photonuclear cross section data. 2. Ev...

  8. Boron neutron capture therapy as new treatment for clear cell sarcoma: Trial on different animal model

    International Nuclear Information System (INIS)

    Clear cell sarcoma (CCS) is a rare malignant tumor with a poor prognosis. In our previous study, the tumor disappeared under boron neutron capture therapy (BNCT) on subcutaneously-transplanted CCS-bearing animals. In the present study, the tumor disappeared under this therapy on model mice intramuscularly implanted with three different human CCS cells. BNCT led to the suppression of tumor-growth in each of the different model mice, suggesting its potentiality as an alternative to, or integrative option for, the treatment of CCS. - Highlights: • BNCT with the use of L-BPA was applied for three human clear cell sarcoma (CCS) cell lines. • BNCT trial was performed on a newly established intramuscularly CCS-bearing animal model. • A significant decrease of the tumor-volume was seen by single BNCT with the use of L-BPA. • A multiple BNCT application would be required for controlling the growth of any residual tumors

  9. Dose Determination using alanine detectors in a Mixed Neutron and Gamma Field for Boron Neutron Capture Therapy of Liver Malignancies

    DEFF Research Database (Denmark)

    Schmitz, T.; Blaickner, M.; Ziegner, M.;

    2011-01-01

    Introduction Boron Neutron Capture Therapy for liver malignancies is being investigated at the University of Mainz. One important aim is the set-up of a reliable dosimetry system. Alanine dosimeters have previously been applied for dosimetry of mixed radiation fields in antiproton therapy, and may...

  10. Proceedings of workshop on 'boron chemistry and boron neutron capture therapy'

    International Nuclear Information System (INIS)

    This volume contains the proceedings of the 4th Workshop on 'the Boron Chemistry and Boron Neutron Capture Therapy' held on February 24 in 1992. First, clinical experiences of BNCT in the Kyoto University Research Reactor in 1992 were briefly reported. Then, the killing effects of boron cluster-containing nucleic acid precursors on tumor cells were shown (Chap. 2). The various trials of the optical resolution of B-p-boronophenylalanine for neutron capture therapy were made (Chap. 3). The borate-dextran gel complexes were investigated by the nuclear magnetic resonance spectroscopy. The stability constants of borate complexes were listed, and are useful in the solution chemistry of boron compounds (Chap. 4). The interactions between boron compounds and biological materials were studied by the paper electrophoresis which had been developed by us (Chap. 5). Molecular design of boron-10 carriers and their organic synthesis were reported (Chap. 6). Carborane-containing aziridine boron carriers which were directed to the DNA alkylation were synthesized and their cancer cell killing efficacies were tested (Chap. 7). The solution chemistry of deuterium oxide which is a good neutron moderator was reported, relating to the BNCT (Chap. 8). (author)

  11. NCT: pacote de tratamento de coordenadas normais (versão 7) NCT: normal coordinate treatment package (version 7)

    OpenAIRE

    Yoshiyuki Hase

    2004-01-01

    A new version of the normal coordinate analysis package NCT is presented. The upgrade was mainly devised to enable the NCT package to manipulate easily the Hessian matrix evaluated by quantum chemical calculations. Program codes were almost wholly rewritten to be more efficient with GNU Fortran77, or g77, and compiled under FreeBSD and MS-DOS with the DJGPP implementation. Three typical usages of the program package are presented by giving the related input and output files. Functionality of ...

  12. Spectromicroscopy of boron for the optimization of boron neutron capture therapy (BNCT) for cancer

    Science.gov (United States)

    Gilbert, B.; Redondo, J.; Baudat, P.-A.; Lorusso, G. F.; Andres, R.; Van Meir, E. G.; Brunet, J.-F.; Hamou, M.-F.; Suda, T.; Mercanti, Delio; Ciotti, M. Teresa; Droubay, T. C.; Tonner, B. P.; Perfetti, P.; Margaritondo, M.; DeStasio, Gelsomina

    1998-10-01

    We used synchrotron spectromicroscopy to study the microscopic distribution of boron in rat brain tumour and healthy tissue in the field of boron neutron capture therapy (BNCT). The success of this experimental cancer therapy depends on the preferential uptake of ? in tumour cells after injection of a boron compound (in our case ?, or BSH). With the Mephisto (microscope à emission de photoélectrons par illumination synchrotronique de type onduleur) spectromicroscope, high-magnification imaging and chemical analysis was performed on brain tissue sections from a rat carrying an implanted brain tumour and the results were compared with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) detection of boron in bulk tissue. Boron was found to have been taken up more favourably by regions of tumour rather than healthy tissue, but the resulting boron distribution in the tumour was inhomogeneous. The results demonstrate that Mephisto can perform microchemical analysis of tissue sections, detect and localize the presence of boron with submicron spatial resolution. The application of this technique to boron in brain tissue can therefore be used to evaluate the current efforts to optimize BNC therapy.

  13. Spectromicroscopy of boron for the optimization of boron neutron capture therapy (BNCT) for cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, B.; Redondo, J.; Baudat, P-A. [Institut de Physique Appliquee, Ecole Polytechnique Federale, Lausanne (Switzerland)] [and others

    1998-10-07

    We used synchrotron spectromicroscopy to study the microscopic distribution of boron in rat brain tumour and healthy tissue in the field of boron neutron capture therapy (BNCT). The success of this experimental cancer therapy depends on the preferential uptake of {sup 10}B in tumour cells after injection of a boron compound (in our case B{sub 12}H{sub 11}SH, or BSH). With the Mephisto (microscope a emission de photoelectrons par illumination synchrotronique de type onduleur) spectromicroscope, high-magnification imaging and chemical analysis was performed on brain tissue sections from a rat carrying an implanted brain tumour and the results were compared with inductively coupled plasma-atomic emission spectroscopy (ICP-AES) detection of boron in bulk tissue. Boron was found to have been taken up more favourably by regions of tumour rather than healthy tissue, but the resulting boron distribution in the tumour was inhomogeneous. The results demonstrate that Mephisto can perform microchemical analysis of tissue sections, detect and localize the presence of boron with submicron spatial resolution. The application of this technique to boron in brain tissue can therefore be used to evaluate the current efforts to optimize BNC therapy. (author)

  14. Gel dosimeters as useful dose and thermal-fluence detectors in Boron Neutron Capture Therapy (BNCT)

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Valente, M. [Department of Physics of the University and INFN, Via Celoria 16, I-20133 Milan (Italy); Moss, R.L.; Daquino, G.G.; Nievaart, V.A. [Joint Research Centre, Institute for Energy, P.O. Box 2, NL-1755ZG Petten, The Netherlands (Netherlands); Mariani, M.; Vanossi, E. [Department of Nuclear Engineering of Polytechnic, CESNEF, Via Ponzio, 34/3 - I-20133 Milan (Italy); Carrara, M. [Medical Physics Department, National Cancer Institute, Via Venezian 1, I-20131, Milan (Italy)

    2006-07-01

    The dosimetry method based on Fricke-Xylenol-Orange-infused gels in form of layers has shown noticeable potentiality for in-phantom or in-free-beam dose and thermal flux profiling and imaging in the high fluxes of thermal or epithermal neutrons utilised for boron neutron capture therapy (BNCT). Gel-dosimeters in form of layers give the possibility not only of obtaining spatial dose distributions but also of achieving measurements of each dose contribution in neutron fields. The discrimination of the various dose components is achieved by means of pixel-to-pixel manipulations of pairs of images obtained with gel-dosimeters having different isotopic composition. It is possible to place large dosimeters, detecting in such a way large dose images, because the layer geometry of dosimeters avoids sensitive variation of neutron transport due to the gel isotopic composition. Some results obtained after the last improvements of the method are reported. (Author)

  15. Biological models in vivo for boron neutronic capture studies as tumors therapy

    International Nuclear Information System (INIS)

    The use of experimental models for Boron Neutronic Capture studies as Tumors Therapy have as two main objectives: 1) To contribute to the basic knowledge of the biological mechanisms involved to increase the method therapeutical advantage, and 2) To explore the possible application of this therapeutic method to other pathologies. In this frame it was studied the carcinogenesis model of hamster cheek pouch, a type of human buccal cancer. Biodistribution studies of boron compound were performed in tumor, blood and in different precancerous and normal tissues as well as BNCT studies. Results validated this method for BNCT studies and show the capacity of the oral mucosa tumors of selectively concentrate the boron compound, showing a deleterious clear effect on the tumor after 24 hours with BNCT treatment. (author)

  16. New concepts for compact accelerator/target for Boron Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Two new target concepts, NIFTI and DISCOS, that enable a large reduction in the proton beam current needed to produce epithermal neutrons for BNCT (Boron Neutron Capture Therapy) are described. In the NIFTI concept, high energy neutrons produced by (p, n) reactions of 2.5 MeV protons on Li are down scattered to treatment energies (∼ 20 keV) by relatively thin layers of PbF2 and iron. In the DISCOS concept, treatment energy neutrons are produced directly in a succession of thin (∼ 1 micron) liquid Li films on rotating Be foils. These foils interact with a proton beam that operates just above threshold for the (p, n) reaction, with an applied DC field to re-accelerate the proton beam between the target foils

  17. FiR 1 Reactor in Service for Boron Neutron Capture Therapy (BNCT) and Isotope Production

    International Nuclear Information System (INIS)

    The FiR 1 reactor, a 250 kW Triga reactor, has been in operation since 1962. The main purpose to run the reactor is now the Boron Neutron Capture Therapy (BNCT). Although BNCT dominates the current utilization of the reactor, it also has an important national role in providing local enterprises and research institutions in the fields of industrial measurements, pharmaceuticals, electronics, etc. with isotope produc- tion and activation analysis services. The whole reactor building has been renovated, creating a dedicated clinical BNCT facility at the reactor. Close to 30 patients have been treated since May 1999, when the licence for patient treatment was granted to the responsible BNCT treatment organization. The treatment organization has a close connection to the Helsinki University Central Hospital. (author)

  18. Establishment of optimal thermal neutron capture therapy for 5 types of human malignant melanoma

    International Nuclear Information System (INIS)

    A series of boron neutron capture therapy (BNCT) studies has already germinated in 1972, with a view to establishing the BNCT particularly suited for the treatment of various types of malignant melanoma, and has been succeeded by research teams comprised of multi-disciplinary members. Twelve patients (7 men and 5 women, aged from 50 to 85 years) with malignant melanoma have been treated with BNCT; among them, six patients were completely cured, four had extremely reduced tumors, and two were still in the clinical process. The present Progress Report is a compilation of 39 research presentations for the recent two years. In this report, three patients are described. Of these, one patient had deep-seated lesions in right and left lymph nodes. These lesions were cured by the use of D2O that allowed neutron beams to reach them. Application of positron emission tomography to the diagnosis of melanoma is a highlight in this Report. (N.K.)

  19. Gel dosimeters as useful dose and thermal-fluence detectors in Boron Neutron Capture Therapy (BNCT)

    International Nuclear Information System (INIS)

    The dosimetry method based on Fricke-Xylenol-Orange-infused gels in form of layers has shown noticeable potentiality for in-phantom or in-free-beam dose and thermal flux profiling and imaging in the high fluxes of thermal or epithermal neutrons utilised for boron neutron capture therapy (BNCT). Gel-dosimeters in form of layers give the possibility not only of obtaining spatial dose distributions but also of achieving measurements of each dose contribution in neutron fields. The discrimination of the various dose components is achieved by means of pixel-to-pixel manipulations of pairs of images obtained with gel-dosimeters having different isotopic composition. It is possible to place large dosimeters, detecting in such a way large dose images, because the layer geometry of dosimeters avoids sensitive variation of neutron transport due to the gel isotopic composition. Some results obtained after the last improvements of the method are reported. (Author)

  20. Incorporation and characterization of boron neutron capture therapy agents into mesoporous silicon and silicon nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ke; Coffer, Jeffery L. [Department of Chemistry, Texas Christian University, Fort Worth, TX 76129 (United States); Loni, Armando; Canham, Leigh T. [PSi Medica Ltd., Malvern, Worcestershire, WR14 3SZ (United Kingdom); Intrinsiq Materials Ltd., Malvern, Worcestershire, WR14 3SZ (United Kingdom)

    2009-06-15

    The tunable pore size, biodegradability, and surface chemistry of mesoporous silicon (BioSilicon trademark) are important to a broad spectrum of uses for drug delivery. For the case of Boron Neutron Capture Therapy (BNCT), encapsulation of a given boron-containing drug molecule within a porous BioSilicon trademark microparticle provides a vehicle for a brachytherapy method that avoids the necessity of drug modification. In this work, the loading and characterization of three clinically approved BNCT drugs into mesoporous Si is demonstrated. Because of difficulties associated with light element detection, a method based on a Beer's Law analysis of selected FTIR vibrational bands has been developed to estimate boron-containing drug loading in these materials. As a complementary nanostructural platform, a cathodic deposition process for the surface enriched growth of selected drugs onto the surface of silicon nanowires is also described. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. DNA damage induced by boron neutron capture therapy is partially repaired by DNA ligase IV.

    Science.gov (United States)

    Kondo, Natsuko; Sakurai, Yoshinori; Hirota, Yuki; Tanaka, Hiroki; Watanabe, Tsubasa; Nakagawa, Yosuke; Narabayashi, Masaru; Kinashi, Yuko; Miyatake, Shin-ichi; Hasegawa, Masatoshi; Suzuki, Minoru; Masunaga, Shin-ichiro; Ohnishi, Takeo; Ono, Koji

    2016-03-01

    Boron neutron capture therapy (BNCT) is a particle radiation therapy that involves the use of a thermal or epithermal neutron beam in combination with a boron ((10)B)-containing compound that specifically accumulates in tumor. (10)B captures neutrons and the resultant fission reaction produces an alpha ((4)He) particle and a recoiled lithium nucleus ((7)Li). These particles have the characteristics of high linear energy transfer (LET) radiation and therefore have marked biological effects. High-LET radiation is a potent inducer of DNA damage, specifically of DNA double-strand breaks (DSBs). The aim of the present study was to clarify the role of DNA ligase IV, a key player in the non-homologous end-joining repair pathway, in the repair of BNCT-induced DSBs. We analyzed the cellular sensitivity of the mouse embryonic fibroblast cell lines Lig4-/- p53-/- and Lig4+/+ p53-/- to irradiation using a thermal neutron beam in the presence or absence of (10)B-para-boronophenylalanine (BPA). The Lig4-/- p53-/- cell line had a higher sensitivity than the Lig4+/+ p53-/-cell line to irradiation with the beam alone or the beam in combination with BPA. In BNCT (with BPA), both cell lines exhibited a reduction of the 50 % survival dose (D 50) by a factor of 1.4 compared with gamma-ray and neutron mixed beam (without BPA). Although it was found that (10)B uptake was higher in the Lig4+/+ p53-/- than in the Lig4-/- p53-/- cell line, the latter showed higher sensitivity than the former, even when compared at an equivalent (10)B concentration. These results indicate that BNCT-induced DNA damage is partially repaired using DNA ligase IV. PMID:26573366

  2. Tomographic image of prompt gamma ray from boron neutron capture therapy: A Monte Carlo simulation study

    International Nuclear Information System (INIS)

    The resulting neutron captures in 10B are used for radiation therapy. The occurrence point of the characteristic 478 keV prompt gamma rays agrees with the neutron capture point. If these prompt gamma rays are detected by external instruments such as a gamma camera or single photon emission computed tomography (SPECT), the therapy region can be monitored during the treatment using images. A feasibility study and analysis of a reconstructed image using many projections (128) were conducted. The optimization of the detection system and a detailed neutron generator simulation were beyond the scope of this study. The possibility of extracting a 3D BNCT-SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The quality of the prompt gamma ray SPECT image obtained from BNCT was evaluated quantitatively using three different boron uptake regions and was shown to depend on the location and size relations. The prospects for obtaining an actual BNCT-SPECT image were also estimated from the quality of the simulated image and the simulation conditions. When multi tumor regions should be treated using the BNCT method, a reasonable model to determine how many useful images can be obtained from SPECT can be provided to the BNCT facilities based on the preceding imaging research. However, because the scope of this research was limited to checking the feasibility of 3D BNCT-SPECT image reconstruction using multiple projections, along with an evaluation of the image, some simulation conditions were taken from previous studies. In the future, a simulation will be conducted that includes optimized conditions for an actual BNCT facility, along with an imaging process for motion correction in BNCT. Although an excessively long simulation time was required to obtain enough events for image reconstruction, the feasibility of acquiring a 3D BNCT-SPECT image using multiple projections was confirmed using a Monte Carlo simulation, and a quantitative image analysis was

  3. The design, construction and performance of a variable collimator for epithermal neutron capture therapy beams

    Science.gov (United States)

    Riley, K. J.; Binns, P. J.; Ali, S. J.; Harling, O. K.

    2004-05-01

    A patient collimator for the fission converter based epithermal neutron beam (FCB) at the Massachusetts Institute of Technology Research Reactor (MITR-II) was built for clinical trials of boron neutron capture therapy (BNCT). A design was optimized by Monte Carlo simulations of the entire beam line and incorporates a modular construction for easy modifications in the future. The device was formed in-house by casting a mixture of lead spheres (7.6 mm diameter) in epoxy resin loaded with either 140 mg cm-3 of boron carbide or 210 mg cm-3 of lithium fluoride (95% enriched in 6Li). The cone shaped collimator allows easy field placement anywhere on the patient and is equipped with a laser indicator of central axis, beam's eye view optics and circular apertures of 80, 100, 120 and 160 mm diameter. Beam profiles and the collateral dose in a half-body phantom were measured for the 160 mm field using fission counters, activation foils as well as tissue equivalent (A-150) and graphite walled ionization chambers. Leakage radiation through the collimator contributes less than 10% to the total collateral dose up to 0.15 m beyond the edge of the aperture and becomes relatively more prominent with lateral displacement. The measured whole body dose equivalent of 24 ± 2 mSv per Gy of therapeutic dose is comparable to doses received during conventional therapy and is due principally (60-80%) to thermal neutron capture reactions with boron. These findings, together with the dose distributions for the primary beam, demonstrate the suitability of this patient collimator for BNCT.

  4. Neutron capture therapy for cancer: development at the National Atomic Energy Commission

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) involves the concurrent presence of a flux of neutrons of adequate energy and Boron 10 as a capture agent. They interact to damage tumor cells but fail to produce significant damage to healthy tissue because the destructive effect occurs mainly in the tumor cells that have selectively accumulated boron. This technique is applied for the treatment of brain tumors of the glioblastoma multiform type and melanoma in different locations. The aim of this project at CNEA is to develop the technological, scientific, clinical know-how and facilities to undertake clinical trials in Argentina. The development of the irradiation facility, the clinical beam and dosimetry was developed at the RA-6 reactor, Bariloche Atomic Center. Treatment planning, instrumentation for the neutron beam, boron measurements, neutron beam for small animal irradiation at the RA-1 reactor and basic research in radiobiology, microdosimetry and autoradiography were developed at Constituyentes Atomic Center. It is also conducted an intense activity in accelerator based BNCT. The infusions to be injected to the patients are prepared at Ezeiza Atomic Center. The clinics of BNCT radiotherapy is developed at the Roffo Institute of Oncology and the neurosurgery at the Argerich Hospital. At present, the project is close to start in the following months to treat melanoma in the limbs, when the authorization procedure is completed. (author)

  5. Proceedings of workshop on 'boron chemistry and boron neutron capture therapy'

    International Nuclear Information System (INIS)

    This volume contains the proceedings of the 5th Workshop on 'the Boron Chemistry and Boron Neutron Capture Therapy' held on February 22 in 1993. The solubility of the boron carrier play an important role in the BNCT. New water-soluble p-boronophenylalanine derivatives are synthesized and their biological activities are investigated (Chap. 2 and 3). Some chemical problems on the BNCT were discussed, and the complex formation reaction of hydroxylboryl compounds were studied by the paper electrophoresis (Chap. 4). The results of the medical investigation on the BNCT using BSH compounds are shown in Chap. 5. Syntheses of o- and m-boronophenylalanine were done and their optical resolution was tried (Chap. 6). The complex formation reaction of p-boronophenylalanine (BPA) with L-DOPA and the oxidation reaction of the analogs are found in Chap. 7. The pka of BPA were determined by the isotachophoresis (Chap. 8). The chemical nature of dihydroxyboryl compounds were investigated by an infrared spectroscopy and electrophoresis (Chap. 9). New synthetic methods of BPA and p-boronophenylserine using ester of isocyanoacetic acid are described in Chap. 10. The induction of chromosomal aberations by neutron capture reaction are discussed from a point of the biological view. The a of the presented papers are indexed individually. (J.P.N.)

  6. Indication and possibility of boron neutron capture therapy in head and neck cancer

    International Nuclear Information System (INIS)

    Background: Boron neutron capture therapy (BNCT) is a targeted type of radiotherapy that has a number of significant advantages over conventional external beam photon irradiation, especially in that radiation can be selectively delivered to tumor cells. We had, first in the world, treated with BNCT for a patient with recurrent head and neck cancer (HNC) in 2001. Methods : From December, 2001 to February, 2013, we had treated 37 patients with recurrent HNC by means of 54 applications of BNCT at Kyoto University Research Reactor Institute (KURRI) and Japan Atomic Energy Agency (JAEA). All of them had received standard therapy and subsequently developed recurrent disease for which there were no other treatment options. Results : All of the (1) Regression rates were complete response (CR) : 19 patients (51%), partial response (PR) : 14(38%), progressive disease (PD) : 3(8%), and not evaluated (NE) : 1(3%) patient. (2) The overall patient response rate was 91%, though all the patients had advanced disease. The 4-year and 7-year OS rates were 42% and 36%, respectively. (3) BNCT improved quality of life (QOL), performance status (PS) and survival times. (4) The primary adverse events were brain necrosis, osteomyelitis and transient mucositis and alopecia. Conclusions : Our results indicate that we could make sure that safety and effectiveness of BNCT, and BNCT represents a new and promising treatment modality in patients for whom there are no other treatment options. (author)

  7. Boron neutron capture therapy for advanced salivary gland carcinoma in head and neck

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a among the radiation treatments known to have a selective lethal effect on tumor cells. This study summarizes the tumor responses and the acute and late adverse effects of BNCT in the treatment of patients with both recurrent and newly diagnosed T4 salivary gland carcinoma. Two patients with recurrent cancer and 3 with newly diagnosed T4 advanced malignancy were registered between October 2003 and September 2007, with the approval of the medical ethics committees of Kawasaki Medical School and Kyoto University. BNCT was performed, in a single fraction using an epithermal beam, at Japan Research Reactor 4. All patients achieved a complete response within 6 months of treatment. The median duration of the complete response was 24.0 months; the median overall survival time was 32.0 months. Three of the 5 patients are still alive; the other 2 died of distant metastatic disease. Open biopsy of the parotid gland after BNCT was performed in 1 patient and revealed no residual viable cancer cells and no serious damage to the normal glandular system. Although mild alopecia, xerostomia, and fatigue occurred in all patients, there were no severe adverse effects of grade 3 or greater. Our preliminary results demonstrate that BNCT is a potential curative therapy for patients with salivary gland carcinoma. The treatment does not cause any serious adverse effects, and may be used regardless of whether the primary tumor has been previously treated. (author)

  8. Potential of using boric acid as a boron drug for boron neutron capture therapy for osteosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, C.F.; Lin, S.Y. [Institute of Nuclear Engineering and Science, National Tsing Hua University, Taiwan (China); Peir, J.J. [Nuclear Science and Technology Development Center, National Tsing Hua University, Taiwan (China); Liao, J.W. [Graduate Institute of Veterinary Pathobiology, National Chung Hsing University, Taiwan (China); Lin, Y.C. [Department of Veterinary Medicine, National Chung Hsing University, Taiwan (China); Chou, F.I., E-mail: fichou@mx.nthu.edu.tw [Institute of Nuclear Engineering and Science, National Tsing Hua University, Taiwan (China)] [Nuclear Science and Technology Development Center, National Tsing Hua University, Taiwan (China)

    2011-12-15

    Osteosarcoma is a malignant tumor commonly found in human and animals. The ability of boric acid (BA) to accumulate in osteosarcoma due to the mechanism of the bone formation of cancer cells would make boron neutron capture therapy (BNCT) an alternative therapy for osteosarcoma. This study evaluated the feasibility of using BA as the boron drug for BNCT of bone cancer. The cytotoxicity of BA to L929 cells exceeded that of UMR-106 cells. With 25 {mu}g {sup 10}B/mL medium of BA treatment, the boron concentration in UMR-106 cells was higher than that in L929 cells. The biodistribution and pharmacokinetics of BA in Sprague-Dawley (SD) rats were studied by administrating 25 mg {sup 10}B/kg body weight to SD rats. Blood boron level decreased rapidly within one hour after BA injection. Boron concentration in the long bone was 4-6 time higher than that of blood. Results of this study suggest that BA may be a potential drug for BNCT for osteosarcoma.

  9. Synthesis and evaluation of boron folates for Boron-Neutron-Capture-Therapy (BNCT)

    Energy Technology Data Exchange (ETDEWEB)

    Kettenbach, Kathrin; Schieferstein, Hanno; Grunewald, Catrin; Hampel, Gabriele; Schuetz, Christian L. [Mainz Univ. (Germany). Inst. of Nuclear Chemistry; Iffland, Dorothee; Bings, Nicolas H. [Mainz Univ. (Germany). Inst. of Inorganic Chemistry and Analytical Chemistry; Reffert, Laura M. [Hannover Medical School (Germany). Radiopharmaceutical Chemistry; Ross, Tobias L. [Mainz Univ. (Germany). Inst. of Nuclear Chemistry; Hannover Medical School (Germany). Radiopharmaceutical Chemistry

    2015-07-01

    Boron neutron capture therapy (BNCT) employs {sup 10}B-pharmaceuticals administered for the treatment of malignancies, and subsequently irradiated with thermal neutrons. So far, clinical established pharmaceuticals like boron phenylalanine (BPA) or sodium boron mercaptate (BSH) use imperfect (BPA) or passive (BSH) targeting for accumulation at target sites. Due to the need of a selective transportation of boron drugs into cancer cells and sparing healthy tissues, we combined the BNCT approach with the specific and effective folate receptor (FR) targeting concept. The FR is overexpressed on many human carcinomas and provides a selective and specific target for molecular imaging as well as for tumor therapy. We synthesized and characterized a carborane-folate as well as a BSH-folate to study their in vitro characteristics and their potential as new boron-carriers for BNCT. Uptake studies were carried out using human KB cells showing a significant increase of the boron content in cells and demonstrating the successful combination of active FR-targeting and BNCT.

  10. Potential of using boric acid as a boron drug for boron neutron capture therapy for osteosarcoma

    International Nuclear Information System (INIS)

    Osteosarcoma is a malignant tumor commonly found in human and animals. The ability of boric acid (BA) to accumulate in osteosarcoma due to the mechanism of the bone formation of cancer cells would make boron neutron capture therapy (BNCT) an alternative therapy for osteosarcoma. This study evaluated the feasibility of using BA as the boron drug for BNCT of bone cancer. The cytotoxicity of BA to L929 cells exceeded that of UMR-106 cells. With 25 μg 10B/mL medium of BA treatment, the boron concentration in UMR-106 cells was higher than that in L929 cells. The biodistribution and pharmacokinetics of BA in Sprague–Dawley (SD) rats were studied by administrating 25 mg 10B/kg body weight to SD rats. Blood boron level decreased rapidly within one hour after BA injection. Boron concentration in the long bone was 4–6 time higher than that of blood. Results of this study suggest that BA may be a potential drug for BNCT for osteosarcoma.

  11. Carborane derivatives loaded into liposomes as efficient delivery systems for boron neutron capture therapy.

    Science.gov (United States)

    Altieri, S; Balzi, M; Bortolussi, S; Bruschi, P; Ciani, L; Clerici, A M; Faraoni, P; Ferrari, C; Gadan, M A; Panza, L; Pietrangeli, D; Ricciardi, G; Ristori, S

    2009-12-10

    Boron neutron capture therapy (BNCT) is an anticancer therapy based on the incorporation of (10)B in tumors, followed by neutron irradiation. Recently, the synthesis and delivery of new boronated compounds have been recognized as some of the main challenges in BNCT application. Here, we report on the use of liposomes as carriers for BNCT active compounds. Two carborane derivatives, i.e., o-closocarboranyl beta-lactoside (LCOB) and 1-methyl-o-closocarboranyl-2-hexylthioporphyrazine (H(2)PzCOB), were loaded into liposomes bearing different surface charges. The efficacy of these formulations was tested on model cell cultures, that is, DHD/K12/TRb rat colon carcinoma and B16-F10 murine melanoma. These induce liver and lung metastases, respectively, and are used to study the uptake of standard BNCT drugs, including borophenylalanine (BPA). Boron concentration in treated cells was measured by alpha spectrometry at the TRIGA mark II reactor (University of Pavia). Results showed high performance of the proposed formulations. In particular, the use of cationic liposomes increased the cellular concentration of (10)B by at least 30 times more than that achieved by BPA. PMID:19954249

  12. Characteristics of a heavy water photoneutron source in boron neutron capture therapy

    Institute of Scientific and Technical Information of China (English)

    Danial Salehi; Dariush Sardari; M.Salehi Jozani

    2013-01-01

    Bremsstrahlung photon beams produced by medical linear accelerators are currently the most commonly used method of radiation therapy for cancerous tumors.Photons with energies greater than 8-10 MeV potentially generate neutrons through photonuclear interactions in the accelerator's treatment head,patient's body,and treatment room ambient.Electrons impinging on a heavy target generate a cascade shower of bremsstrahlung photons,the energy spectrum of which shows an end point equal to the electron beam energy.By varying the target thickness,an optimum thickness exists for which,at the given electron energy,maximum photon flux is achievable.If a source of high-energy photons i.e.bremsstrahlung,is conveniently directed to a suitable D2O target,a novel approach for production of an acceptable flux of filterable photoneturons for boron neutron capture therapy (BNCT) application is possible.This study consists of two parts.1.Comparison and assessment of deuterium photonuclear cross section data.2.Evaluation of the heavy water photonuclear source.

  13. Accelerator-based neutron source for the neutron-capture and fast neutron therapy at hospital

    Science.gov (United States)

    Bayanov, B. F.; Belov, V. P.; Bender, E. D.; Bokhovko, M. V.; Dimov, G. I.; Kononov, V. N.; Kononov, O. E.; Kuksanov, N. K.; Palchikov, V. E.; Pivovarov, V. A.; Salimov, R. A.; Silvestrov, G. I.; Skrinsky, A. N.; Soloviov, N. A.; Taskaev, S. Yu.

    The proton accelerator complex for neutron production in lithium target discussed, which can operate in two modes. The first provides a neutron beam kinematically collimated with good forward direction in 25° and average energy of 30 keV, directly applicable for neutron-capture therapy with high efficiency of proton beam use. The proton energy in this mode is 1.883-1.890 MeV that is near the threshold of the 7Li( p, n) 7Be reaction. In the second mode, at proton energy of 2.5 MeV, the complex-produced neutron beam with maximum energy board of 790 keV which can be used directly for fast neutron therapy and for neutron-capture therapy after moderation. The project of such a neutron source is based on the 2.5 MeV original electrostatic accelerator tandem with vacuum insulation developed at BINP which is supplied with a high-voltage rectifier. The rectifier is produced in BINP as a part of ELV-type industrial accelerator. Design features of the tandem determining its high reliability in operation with a high-current (up to 40 mA) H - ion beam are discussed. They are: the absence of ceramic accelerator columns around the beam passage region, good conditions for pumping out of charge-exchange gaseous target region, strong focusing optics and high acceleration rate minimizing the space charge effects. The possibility of stabilization of protons energy with an accuracy level of 0.1% necessary for operation in the near threshold region is considered. The design description of H - continuous ion source with a current of 40 mA is also performed. To operate with a 100 kW proton beam it is proposed to use liquid-lithium targets. A thin lithium layer on the surface of a tungsten disk cooled intensively by a liquid metal heat carrier is proposed for use in case of the vertical beam, and a flat liquid lithium jet flowing through the narrow nozzle - for the horizontal beam.

  14. Application of generalized perturbation theory to sensitivity analysis in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Vanessa S. [Universidade Federal Fluminense (EEIMVR/UFF-RJ), Volta Redonda, RJ (Brazil). Escola de Engenharia Industrial e Metalurgica. Programa de Pos-Graduacao em Modelagem Computacional em Ciencia e Tecnologia; Silva, Fernando C.; Silva, Ademir X., E-mail: fernando@con.ufrj.b, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Alvarez, Gustavo B. [Universidade Federal Fluminense (EEIMVR/UFF-RJ), Volta Redonda, RJ (Brazil). Escola de Engenharia Industrial e Metalurgica. Dept. de Ciencias Exatas

    2011-07-01

    Boron neutron capture therapy - BNCT - is a binary cancer treatment used in brain tumors. The tumor is loaded with a boron compound and subsequently irradiated by thermal neutrons. The therapy is based on the {sup 10}B (n, {alpha}) {sup 7}Li nuclear reaction, which emits two types of high-energy particles, {alpha} particle and the {sup 7}Li nuclei. The total kinetic energy released in this nuclear reaction, when deposited in the tumor region, destroys the cancer cells. Since the success of the BNCT is linked to the different selectivity between the tumor and healthy tissue, it is necessary to carry out a sensitivity analysis to determinate the boron concentration. Computational simulations are very important in this context because they help in the treatment planning by calculating the lowest effective absorbed dose rate to reduce the damage to healthy tissue. The objective of this paper is to present a deterministic method based on generalized perturbation theory (GPT) to perform sensitivity analysis with respect to the {sup 10}B concentration and to estimate the absorbed dose rate by patients undergoing this therapy. The advantage of the method is a significant reduction in computational time required to perform these calculations. To simulate the neutron flux in all brain regions, the method relies on a two-dimensional neutron transport equation whose spatial, angular and energy variables are discretized by the diamond difference method, the discrete ordinate method and multigroup formulation, respectively. The results obtained through GPT are consistent with those obtained using other methods, demonstrating the efficacy of the proposed method. (author)

  15. Neutron capture therapy of murine melanoma on new boron carriers with use of capillary neutron optics

    Science.gov (United States)

    Borisov, G. I.; Naidenov, M. G.; Koldaeva, E. Y.; Petrov, S. A.; Zhizhin, K. Y.; Kuznettsov, N. T.; Brattsev, V. A.; Grigorieva, E. Y.

    2005-07-01

    The Boron-10 NCT is one of the most perspective methods of human anticancer treatment. The introduction of this efficient method into medical practice makes possible more selective and precise destruction of tumour cells without any damage of normal tissues. The basis of NCT method is destructive effect of products of nuclear reaction 10B(n,α,γ)7Li. This reaction produces particles-helium nuclei (alpha-particles) and lithium nuclei-with too high linear energetic loss in animal tissues and poor integrated sweep (to 14 μm) what is comparable with single cell diameter. Actual use of BNCT for treatment of human malignant tumours is dependent on resolution of various and complex scientific and technical problems. Namely: the development of novel boron preparations selectively carrying 10B into cancer cells, providing optimal concentration and microdistribution of 10B in these and remaining there during all necessary irradiation time; formation of therapeutic neutron fluxes of needed power, spectrum and intensity; provision of adequate planning and monitoring methods for current 10B-NCT making possible to evaluate a boron concentration in animal tissues in real time, to see macro- and microdistribution of the same, allowing precise microdosimetry; optimization of irradiation regimens and of drug administration schedules conformably to concrete neutron flux in different objects.

  16. NCT: pacote de tratamento de coordenadas normais (versão 7 NCT: normal coordinate treatment package (version 7

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Hase

    2004-08-01

    Full Text Available A new version of the normal coordinate analysis package NCT is presented. The upgrade was mainly devised to enable the NCT package to manipulate easily the Hessian matrix evaluated by quantum chemical calculations. Program codes were almost wholly rewritten to be more efficient with GNU Fortran77, or g77, and compiled under FreeBSD and MS-DOS with the DJGPP implementation. Three typical usages of the program package are presented by giving the related input and output files. Functionality of the programs was carefully and satisfactorily checked for some sample calculations.

  17. Selective uptake of p-boronophenylalanine by osteosarcoma cells for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Osteosarcoma is the most common non-hematologic primary cancer type that develops in bone. Current osteosarcoma treatments combine multiagent chemotherapy with extensive surgical resection, which in some cases makes necessary the amputation of the entire limb. Nevertheless its infiltrative growth leads to a high incidence of local and distant recurrences that reduce the percentage of cured patients to less than 60%. These poor data required to set up a new therapeutic approach aimed to restrict the surgical removal meanwhile performing a radical treatment. Boron neutron capture therapy (BNCT), a particular radiotherapy based on the nuclear capture and fission reactions by atoms of 10B, when irradiated with thermal neutrons, could be a valid alternative or integrative option in case of osteosarcoma management, thanks to its peculiarity in selectively destroying neoplastic cells without damaging normal tissues. Aim of the present work is to investigate the feasibility of employing BNCT to treat the limb osteosarcoma. Boronophenylalanine (BPA) is used to carry 10B inside the neoplastic cells. As a first step the endocellular BPA uptake is tested in vitro on the UMR-106 osteosarcoma cell line. The results show an adequate accumulation capability. For the in vivo experiments, an animal tumor model is developed in Sprague-Dawley rats by means of an intrafemoral injection of UMR-106 cells at the condyle site. The absolute amounts of boron loading and the tumor to normal tissue 10B ratio are evaluated 2 h after the i.v. administration of BPA. The boron uptake by the neoplastic tissue is almost twice the normal one. However, higher values of boron concentration in tumor are requested before upholding BNCT as a valid therapeutic option in the treatment of osteosarcoma.

  18. Hemorrhage in mouse tumors induced by dodecaborate cluster lipids intended for boron neutron capture therapy

    Directory of Open Access Journals (Sweden)

    Schaffran T

    2014-07-01

    Full Text Available Tanja Schaffran,1 Nan Jiang,1 Markus Bergmann,2,3 Ekkehard Küstermann,4 Regine Süss,5 Rolf Schubert,5 Franz M Wagner,6 Doaa Awad,7 Detlef Gabel1,2,8 1Department of Chemistry, University of Bremen, 2Institute of Neuropathology, Klinikum Bremen-Mitte; 3Cooperative Center Medicine, University of Bremen, 4“In-vivo-MR” AG, FB2, University of Bremen, Bremen, 5Pharmaceutical Technology, University of Freiburg, Freiburg im Breisgau, 6Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM II, Technische Unversitaet Muenchen, Garching, Germany; 7Department of Biochemistry, Alexandria University, Alexandria, Egypt; 8School of Engineering and Science, Jacobs University Bremen, Bremen, Germany Abstract: The potential of boron-containing lipids with three different structures, which were intended for use in boron neutron capture therapy, was investigated. All three types of boron lipids contained the anionic dodecaborate cluster as the headgroup. Their effects on two different tumor models in mice following intravenous injection were tested; for this, liposomes with boron lipid, distearoyl phosphatidylcholine, and cholesterol as helper lipids, and containing a polyethylene glycol lipid for steric protection, were administered intravenously into tumor-bearing mice (C3H mice for SCCVII squamous cell carcinoma and BALB/c mice for CT26/WT colon carcinoma. With the exception of one lipid (B-THF-14, the lipids were well tolerated, and no other animal was lost due to systemic toxicity. The lipid which led to death was not found to be much more toxic in cell culture than the other boron lipids. All of the lipids that were well tolerated showed hemorrhage in both tumor models within a few hours after administration. The hemorrhage could be seen by in vivo magnetic resonance and histology, and was found to occur within a few hours. The degree of hemorrhage depended on the amount of boron administered and on the tumor model. The observed unwanted effect of the lipids

  19. Can epithermal boron neutron capture therapy treat primary and metastatic liver cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, S.A. [Austin Repatriation Medical Centre, Heidelberg (Australia); Carolan, M.C. [Illawarra Cancer Care Centre, Wollongong (Australia); Allen, B.J. [St George Cancer Care Centre, Kogarah (Australia)

    1996-12-31

    Full text: The poor prognosis of metastatic cancer to the liver calls for the investigation of alternative treatment modalities. This paper analyses the possible use of epithermal boron neutron capture therapy for the palliative treatment of these cancers. We examine possible treatment planning scenarios for selected tumour to liver boron ratios, and specifically for the epithermal beam at the HFR, Petten. It is required that a therapeutic ratio> 1 be achieved over the entire organ. Monte Carlo calculations were performed using the radiation transport code MCNP. The geometrical model used a `variable voxel` technique to reconstruct an anthropomorphic phantom from CT scans. Regions of interest such as the liver were modelled to a resolution of a few millimetres, whereas surrounding regions were modelled with lesser detail thereby facilitating faster computation time. Three dimensional dose distributions were calculated for a frontal beam directed at the liver, and found to be in satisfactory agreement with measurements using bare and cadmium covered gold foils, PIN and MOSFET dosimeters for fast neutron and gamma measurements respectively. Dose distributions were calculated for orthogonal epithermal neutron beams to the front and side, using the parameters of the epithermal beam at Petten, and assumed tumour and normal tissue boron-10 concentrations of 30 ppm and 7.5 ppm boron-10 respectively. The therapeutic ratio (i e the dose to the tumour relative to the maximum dose to normal tissue) was found to be about 1.8, reducing to unity for the limiting condition of a tumour in the posterior liver. This result opens up the possibility of palliative therapy for the management of primary and metastatic liver cancer.

  20. Dosimetric evaluation of neutron capture therapy for local advanced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yanagie, H. [Department of Nuclear Engineering and Management, Graduate School of Engineering, University of Tokyo, Tokyo (Japan); Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan)], E-mail: yanagie@n.t.u-tokyo.ac.jp; Kumada, H. [Japan Atomic Research Institute, Ibaraki (Japan); Sakurai, Y. [Research Reactor Institute, Kyoto University, Osaka (Japan); Nakamura, T. [Japan Atomic Research Institute, Ibaraki (Japan); Department of Nuclear Physics, Ibaraki University, Ibaraki (Japan); Furuya, Y. [Department of Surgery, Satukidai Hospital, Chiba (Japan); Sugiyama, H. [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan); Ono, K. [Research Reactor Institute, Kyoto University, Osaka (Japan); Takamoto, S. [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan); Department of Cardiac Surgery, University of Tokyo Hospital, Tokyo (Japan); Eriguchi, M. [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan); Department of Microbiology, Syowa University School of Pharmaceutical Sciences, Tokyo (Japan); Takahashi, H. [Department of Nuclear Engineering and Management, Graduate School of Engineering, University of Tokyo, Tokyo (Japan); Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan)

    2009-07-15

    Local recurrence breast cancer is one of the most difficult conditions to cure and there is a need for new therapy. If sufficient boron compound can be targeted to the tumor, boron neutron capture therapy (BNCT) can be applied to local recurrent breast cancer. In this study, we performed a preliminary dosimetry with a phantom model of the mammary gland at Kyoto University Research Reactor (KUR), and a feasibility dosimetry with JAERI Computational Dosimetry System (JCDS) at JRR4 reactor of Japan Atomic Research Institute. We performed preliminary dosimetry of a phantom model of the mammary gland with thermal neutron irradiation (OO-0011 mode) on LiF collimation at KUR. The thermal neutron flux was 5.16 E+08 cm{sup -2} s{sup -1} at the surface of phantom. The blood boron concentration is estimated to be 30 ppm; tumor boron concentration is also estimated to be 90 ppm according to tumor/blood ratio 3 and skin/blood ratio 1.2. Tumor RBE dose is estimated to be 47 Gy/h, and skin RBE dose is 12.4 Gy/h. In case of advanced breast cancer, we performed the feasibility estimation of 3D construction of tumor according to the MRI imaging of a patient with epithermal neutron mode at JRR4. The blood boron concentration (ppm) and tumor/normal tissue ratio are estimated to be 24 and 3.5, respectively. Skin RBE dose is restricted to 10 Gy/h, the maximum tumor RBE dose, minimum tumor RBE dose, and mean tumor RBE dose are 42.2, 11.3, and 28.9 Gy-Eq, respectively, in half hour irradiation. In this study, we showed the possibility to apply BNCT to local recurrent breast cancer. We can irradiate tumors selectively and as safely as possible, reducing the effects on neighboring healthy tissues.

  1. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    CERN Document Server

    Kumada, H; Matsumura, A; Nakagawa, Y; Nose, T; Torii, Y; Uchiyama, J; Yamamoto, K; Yamamoto, T

    2003-01-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is...

  2. FiR 1 reactor in service for boron neutron capture therapy (BNCT) and isotope production

    International Nuclear Information System (INIS)

    The FiR 1 reactor, a 250 kW Triga reactor, has been in operation since 1962. The main purpose for the existence of the reactor is now the Boron Neutron Capture Therapy (BNCT), but FiR 1 has also an important national role in providing local enterprises and research institutions in the fields of industrial measurements, pharmaceuticals, electronics etc. with isotope production and activation analysis services. In the 1990's a BNCT treatment facility was built at the FiR 1 reactor located at Technical Research Centre of Finland. A special new neutron moderator material FluentalTM (Al+AlF3+Li) developed at VTT ensures the superior quality of the neutron beam. Also the treatment environment is of world top quality after a major renovation of the whole reactor building in 1997. Recently the lithiated polyethylene neutron shielding of the beam aperture was modified to ease the positioning of the patient close to the beam aperture. Increasing the reactor power to 500 kW would allow positioning of the patient further away from the beam aperture. Possibilities to accomplish a safety analysis for this is currently under considerations. Over thirty patients have been treated at FiR 1 since May 1999, when the license for patient treatment was granted to the responsible BNCT treatment organization, Boneca Corporation. Currently three clinical trial protocols for tumours in the brain as well as in the head and neck region are recruiting patients. (author)

  3. An accelerator-based epithermal photoneutron source for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, H.E.

    1996-04-01

    Boron neutron capture therapy is an experimental binary cancer radiotherapy modality in which a boronated pharmaceutical that preferentially accumulates in malignant tissue is first administered, followed by exposing the tissue in the treatment volume to a thermal neutron field. Current usable beams are reactor-based but a viable alternative is the production of an epithermal neutron beam from an accelerator. Current literature cites various proposed accelerator-based designs, most of which are based on proton beams with beryllium or lithium targets. This dissertation examines the efficacy of a novel approach to BNCT treatments that incorporates an electron linear accelerator in the production of a photoneutron source. This source may help to resolve some of the present concerns associated with accelerator sources, including that of target cooling. The photoneutron production process is discussed as a possible alternate source of neutrons for eventual BNCT treatments for cancer. A conceptual design to produce epithermal photoneutrons by high photons (due to bremsstrahlung) impinging on deuterium targets is presented along with computational and experimental neutron production data. A clinically acceptable filtered epithermal neutron flux on the order of 10{sup 7} neutrons per second per milliampere of electron current is shown to be obtainable. Additionally, the neutron beam is modified and characterized for BNCT applications by employing two unique moderating materials (an Al/AlF{sub 3} composite and a stacked Al/Teflon design) at various incident electron energies.

  4. Thermal neutron irradiation field design for boron neutron capture therapy of human explanted liver.

    Science.gov (United States)

    Bortolussi, S; Altieri, S

    2007-12-01

    The selective uptake of boron by tumors compared to that by healthy tissue makes boron neutron capture therapy (BNCT) an extremely advantageous technique for the treatment of tumors that affect a whole vital organ. An example is represented by colon adenocarcinoma metastases invading the liver, often resulting in a fatal outcome, even if surgical resection of the primary tumor is successful. BNCT can be performed by irradiating the explanted organ in a suitable neutron field. In the thermal column of the Triga Mark II reactor at Pavia University, a facility was created for this purpose and used for the irradiation of explanted human livers. The neutron field distribution inside the organ was studied both experimentally and by means of the Monte Carlo N-particle transport code (MCNP). The liver was modeled as a spherical segment in MCNP and a hepatic-equivalent solution was used as an experimental phantom. In the as-built facility, the ratio between maximum and minimum flux values inside the phantom ((phi(max)/phi(min)) was 3.8; this value can be lowered to 2.3 by rotating the liver during the irradiation. In this study, the authors proposed a new facility configuration to achieve a uniform thermal neutron flux distribution in the liver. They showed that a phi(max)/phi(min) ratio of 1.4 could be obtained without the need for organ rotation. Flux distributions and dose volume histograms were reported for different graphite configurations. PMID:18196797

  5. Improvement of dose distribution by central beam shielding in boron neutron capture therapy

    Science.gov (United States)

    Sakurai, Yoshinori; Ono, Koji

    2007-12-01

    Since boron neutron capture therapy (BNCT) with epithermal neutron beams started at the Kyoto University Reactor (KUR) in June 2002, nearly 200 BNCT treatments have been carried out. The epithermal neutron irradiation significantly improves the dose distribution, compared with the previous irradiation mainly using thermal neutrons. However, the treatable depth limit still remains. One effective technique to improve the limit is the central shield method. Simulations were performed for the incident neutron energies and the annular components of the neutron source. It was clear that thermal neutron flux distribution could be improved by decreasing the lower energy neutron component and the inner annular component of the incident beam. It was found that a central shield of 4-6 cm diameter and 10 mm thickness is effective for the 12 cm diameter irradiation field. In BNCT at KUR, the depth dose distribution can be much improved by the central shield method, resulting in a relative increase of the dose at 8 cm depth by about 30%. In addition to the depth dose distribution, the depth dose profile is also improved. As the dose rate in the central area is reduced by the additional shielding, the necessary irradiation time, however, increases by about 30% compared to normal treatment.

  6. GPU-based prompt gamma ray imaging from boron neutron capture therapy

    International Nuclear Information System (INIS)

    Purpose: The purpose of this research is to perform the fast reconstruction of a prompt gamma ray image using a graphics processing unit (GPU) computation from boron neutron capture therapy (BNCT) simulations. Methods: To evaluate the accuracy of the reconstructed image, a phantom including four boron uptake regions (BURs) was used in the simulation. After the Monte Carlo simulation of the BNCT, the modified ordered subset expectation maximization reconstruction algorithm using the GPU computation was used to reconstruct the images with fewer projections. The computation times for image reconstruction were compared between the GPU and the central processing unit (CPU). Also, the accuracy of the reconstructed image was evaluated by a receiver operating characteristic (ROC) curve analysis. Results: The image reconstruction time using the GPU was 196 times faster than the conventional reconstruction time using the CPU. For the four BURs, the area under curve values from the ROC curve were 0.6726 (A-region), 0.6890 (B-region), 0.7384 (C-region), and 0.8009 (D-region). Conclusions: The tomographic image using the prompt gamma ray event from the BNCT simulation was acquired using the GPU computation in order to perform a fast reconstruction during treatment. The authors verified the feasibility of the prompt gamma ray image reconstruction using the GPU computation for BNCT simulations

  7. Basic study for development of new tumor specific agents for neutron capture therapy

    International Nuclear Information System (INIS)

    New tissue specific agents for neutron capture therapy was studied. Monoclonal labeled gadolinium-DTPA (Gd-MoAb) and porphyrin (ATN-10)-Gd-DTPA (Gd-ATN10) were studied as possible agents by using 9-L experimental brain tumor model. The tissue concentration were analyzed with magnetic resonance imaging (MRI) and inductively coupled plasma (ICP) analyzer. Gd-MoAb showed persistent retention in the tumor on MRI, but tissue gadolinium concentration was not detectable in the tumor by ICP analyzer, while there was high accumulation of Gd-MoAb in the liver. Gd-ATN10 showed prolonged and high accumulation in the tumor up to 48 hours on MRI. Gadolinium concentration reached up to 9 ppm in the tumor by 0.02 mmol/kg administration, but it disappeared within 6 hours after administration. This dissociation between MRI and ICP analysis was due to separation of ATN-10 and Gd-DTPA. As conclusions, the porphyrin compounds are potential agents for delivering gadolinium or boron specific to the tumor tissue, thus further improvement such as more stable conjugation between porphyrinfic to the tumor tissue, thus further improvement such as more stable conjugation between porphyrin and Gd-DTPA is needed. (author)

  8. An accelerator-based epithermal photoneutron source for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Boron neutron capture therapy is an experimental binary cancer radiotherapy modality in which a boronated pharmaceutical that preferentially accumulates in malignant tissue is first administered, followed by exposing the tissue in the treatment volume to a thermal neutron field. Current usable beams are reactor-based but a viable alternative is the production of an epithermal neutron beam from an accelerator. Current literature cites various proposed accelerator-based designs, most of which are based on proton beams with beryllium or lithium targets. This dissertation examines the efficacy of a novel approach to BNCT treatments that incorporates an electron linear accelerator in the production of a photoneutron source. This source may help to resolve some of the present concerns associated with accelerator sources, including that of target cooling. The photoneutron production process is discussed as a possible alternate source of neutrons for eventual BNCT treatments for cancer. A conceptual design to produce epithermal photoneutrons by high photons (due to bremsstrahlung) impinging on deuterium targets is presented along with computational and experimental neutron production data. A clinically acceptable filtered epithermal neutron flux on the order of 107 neutrons per second per milliampere of electron current is shown to be obtainable. Additionally, the neutron beam is modified and characterized for BNCT applications by employing two unique moderating materials (an Al/AlF3 composite and a stacked Al/Teflon design) at various incident electron energies

  9. Design of an accelerator-based neutron source for neutron capture therapy

    International Nuclear Information System (INIS)

    The boron neutron capture therapy is mainly suited in the treatment of some tumor kinds which revealed ineffective to the traditional radiotherapy. In order to take advantage of such a therapeutic modality in hospital environments, neutron beams of suitable energy and flux levels provided by compact size facilities are needed. The advantages and drawbacks of several neutron beams are here analysed in terms of therapeutic gains. In detail the GEANT-3/MICAP simulations show that high tumor control probability, with sub-lethal dose at healthy tissues, can be achieved by using neutron beams of few keV energy having a flux of about 109 neutrons/(cm2 s). To produce such a neutron beam, the feasibility of a proton accelerator is investigated. In particular an appropriate choice of the radiofrequency parameters (modulation, efficiency of acceleration, phase shift, etc.) allows the development of relatively compact accelerators, having a proton beam current of 30 mA and an energy of 2 MeV, which could eventually lead to setting up of hospital-based neutron facilities.

  10. Boron neutron capture therapy outcomes for advanced or recurrent head and neck cancer

    International Nuclear Information System (INIS)

    We retrospectively review outcomes of applying boron neutron capture therapy (BNCT) to unresectable advanced or recurrent head and neck cancers. Patients who were treated with BNCT for either local recurrent or newly diagnosed unresectable head or neck cancers between December 2001 and September 2007 were included. Clinicopathological characteristics and clinical outcomes were retrieved from hospital records. Either a combination of borocaptate sodium and boronophenylalanine (BPA) or BPA alone were used as boron compounds. In all the treatment cases, the dose constraint was set to deliver a dose <10–12 Gy-eq to the skin or oral mucosa. There was a patient cohort of 62, with a median follow-up of 18.7 months (range, 0.7–40.8). A total of 87 BNCT procedures were performed. The overall response rate was 58% within 6 months after BNCT. The median survival time was 10.1 months from the time of BNCT. The 1- and 2-year overall survival (OS) rates were 43.1% and 24.2%, respectively. The major acute Grade 3 or 4 toxicities were hyperamylasemia (38.6%), fatigue (6.5%), mucositis/stomatitis (9.7%) and pain (9.7%), all of which were manageable. Three patients died of treatment-related toxicity. Three patients experienced carotid artery hemorrhage, two of whom had coexistent infection of the carotid artery. This study confirmed the feasibility of our dose-estimation method and that controlled trials are warranted. (author)

  11. Effectiveness of boron neutron capture therapy for recurrent head and neck malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Itsuro [Department of Oral and Maxillofacial Surgery, II Osaka University, Graduate School of Dentistry, Osaka (Japan)], E-mail: katoitsu@dent.osaka-u.ac.jp; Fujita, Yusei [Department of Oral and Maxillofacial Surgery, II Osaka University, Graduate School of Dentistry, Osaka (Japan); Maruhashi, Akira [Radiation Oncology Research Laboratory, Research Reactor Institut, Kyoto University, Osaka (Japan); Kumada, Hiroaki [Japan Atomic Energy Agency, Tokai Research and Development Center, Ibaraki (Japan); Ohmae, Masatoshi [Department of Oral and Maxillofacial Surgery, Izimisano Municipal Hospital, Rinku General Hospital, Izumisano, Osaka (Japan); Kirihata, Mitsunori [Graduate School of Environment and Life Science, Osaka prefectural University, Osaka (Japan); Imahori, Yoshio [Department of Neurosurgery, Kyoto Prefectural University, Kyoto (Japan); CEO of Cancer Intelligence Care Systems, Inc., Tokyo (Japan); Suzuki, Minoru [Radiation Oncology Research Laboratory, Research Reactor Institut, Kyoto University, Osaka (Japan); Sakrai, Yoshinori [Graduate School of Medicine, Sapporo Medical University of Medicine, Hokkaido (Japan); Sumi, Tetsuro; Iwai, Soichi; Nakazawa, Mitsuhiro [Department of Oral and Maxillofacial Surgery, II Osaka University, Graduate School of Dentistry, Osaka (Japan); Murata, Isao; Miyamaru, Hiroyuki [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University (Japan); Ono, Koji [Radiation Oncology Research Laboratory, Research Reactor Institut, Kyoto University, Osaka (Japan)

    2009-07-15

    It is necessary to explore new treatments for recurrent head and neck malignancies (HNM) to avoid severe impairment of oro-facial structures and functions. Boron neutron capture therapy (BNCT) is tumor-cell targeted radiotherapy that has significant superiority over conventional radiotherapies in principle. We have treated with BNCT 42 times for 26 patients (19 squamous cell carcinomas (SCC), 4 salivary gland carcinomas and 3 sarcomas) with a recurrent and far advanced HNM since 2001. Results of (1) {sup 10}B concentration of tumor/normal tissue ratios (T/N ratio) of FBPA-PET studies were SCC: 1.8-5.7, sarcoma: 2.5-4.0, parotid tumor: 2.5-3.7. (2) Therapeutic effects were CR: 12 cases, PR: 10 cases, PD: 3 cases NE (not evaluated): 1 case. Response rate was 85%. (3) Improvement of QOL such as a relief of severe pain, bleeding, and exudates at the local lesion, improvement of PS, disappearance of ulceration, covered with normal skin and preserved oral and maxillofacial functions and tissues. (4) Survival periods after BNCT were 1-72 months (mean: 13.6 months). Six-year survival rate was 24% by Kaplan-Meier analysis. (5) Adverse-events were transient mucositis and alopecia in most of the cases; three osteomyelitis and one brain necrosis were recognized. These results indicate that BNCT represents a new and promising treatment approach for advanced HNM.

  12. A fundamental study on hyper-thermal neutrons for neutron capture therapy.

    Science.gov (United States)

    Sakurai, Y; Kobayashi, T; Kanda, K

    1994-12-01

    The utilization of hyper-thermal neutrons, which have an energy spectrum with a Maxwellian distribution at a higher temperature than room temperature (300 K), was studied in order to improve the thermal neutron flux distribution at depth in a living body for neutron capture therapy. Simulation calculations were carried out using a Monte Carlo code 'MCNP-V3' in order to investigate the characteristics of hyper-thermal neutrons, i.e. (i) depth dependence of the neutron energy spectrum, and (ii) depth distribution of the reaction rate in a water phantom for materials with 1/v neutron absorption. It is confirmed that hyper-thermal neutron irradiation can improve the thermal neutron flux distribution in the deeper areas in a living body compared with thermal neutron irradiation. When hyper-thermal neutrons with a 3000 K Maxwellian distribution are incident on a body, the reaction rates of 1/v materials such as 14N, 10B etc are about twice that observed for incident thermal neutrons at 300 K, at a depth of 5 cm. The limit of the treatable depth for tumours having 30 ppm 10B is expected to be about 1.5 cm greater by utilizing hyper-thermal neutrons at 3000 K compared with the incidence of thermal neutrons at 300 K.

  13. High-power liquid-lithium target prototype for accelerator-based boron neutron capture therapy.

    Science.gov (United States)

    Halfon, S; Paul, M; Arenshtam, A; Berkovits, D; Bisyakoev, M; Eliyahu, I; Feinberg, G; Hazenshprung, N; Kijel, D; Nagler, A; Silverman, I

    2011-12-01

    A prototype of a compact Liquid-Lithium Target (LiLiT), which will possibly constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals, was built. The LiLiT setup is presently being commissioned at Soreq Nuclear Research Center (SNRC). The liquid-lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power generated using a high-intensity proton beam (>10 kW), necessary for sufficient neutron flux. In off-line circulation tests, the liquid-lithium loop generated a stable lithium jet at high velocity, on a concave supporting wall; the concept will first be tested using a high-power electron beam impinging on the lithium jet. High intensity proton beam irradiation (1.91-2.5 MeV, 2-4 mA) will take place at Soreq Applied Research Accelerator Facility (SARAF) superconducting linear accelerator currently in construction at SNRC. Radiological risks due to the (7)Be produced in the reaction were studied and will be handled through a proper design, including a cold trap and appropriate shielding. A moderator/reflector assembly is planned according to a Monte Carlo simulation, to create a neutron spectrum and intensity maximally effective to the treatment and to reduce prompt gamma radiation dose risks.

  14. Sonoporation as an enhancing method for boron neutron capture therapy for squamous cell carcinomas

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a selective radiotherapy that is dependent on the accumulation of 10B compound in tumors. Low-intensity ultrasound produces a transient pore on cell membranes, sonoporation, which enables extracellular materials to enter cells. The effect of sonoporation on BNCT was examined in oral squamous cell carcinoma (SCC) xenografts in nude mice. Tumor-bearing mice were administrated boronophenylalanine (BPA) or boronocaptate sodium (BSH) intraperitoneally. Two hours later, tumors were subjected to sonoporation using microbubbles followed by neutron irradiation. The 10B concentration was higher in tumors treated with sonoporation than in untreated tumors, although the difference was not significant in BPA. When tumors in mice that received BPA intraperitoneally were treated with sonoporation followed by exposure to thermal neutrons, tumor volume was markedly reduced and the survival rate was prolonged. Such enhancements by sonoporation were not observed in mice treated with BSH-mediated BNCT. These results indicate that sonoporation enhances the efficiency of BPA-mediated BNCT for oral SCC. Sonoporation may modulate the microlocalization of BPA and BSH in tumors and increase their intracellular levels

  15. A novel reactor concept for boron neutron capture therapy: annular low-low power reactor (ALLPR)

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, B.; Levine, S.H. [Department of Nuclear Engineering, Pennsylvania State University, University Park, PA 16802 (United States)

    1998-07-01

    Boron Neutron Capture Therapy (BNC), originally proposed in 50's, has been getting renewed attention over the last {approx}10 years. This is in particular due to its potential for treating deep-seated brain tumors by employing epithermal neutron beams. Large (several MW) research reactors are currently used to obtain epithermal beams for BNCT, but because of cost and licensing issues it is not likely that such high-power reactors can be placed in regular medical centers. This paper describes a novel reactor concept for BNCT devised to overcome this obstacle. The design objective was to produce a beam of epithermal neutrons of sufficient intensity for BNCT at <50 kW using low enriched uranium. It is achieved by the annular reactor design, which is called Annular Low-Low Power Reactor (ALLPR). Preliminary studies using Monte Carlo simulations are summarized in this paper. The ALLPR should be relatively economical to build, and safe and easy to operate. This novel concept may increase the viability of using BNCT in medical centers worldwide. (author)

  16. Modelling collimator of radial beam port Kartini reactor for boron neutron capture therapy

    International Nuclear Information System (INIS)

    One of the cancer therapy methods is BNCT (Boron Neutron Capture Therapy). BNCT utilizes neutron nature by 10B deposited on cancer cells. The superiority of BNCT compared to the radiation therapy is the high level of selectivity since its level is within cell. This study was carried out on collimator modelling in radial beam port of reactor Kartini for BNCT. The modelling was conducted by simulation using software of Monte Carlo N-Particle version 5 (MCNP 5). MCNP5 is a package of the programs for both simulating and calculating the problem of particle transport by following the life cycle of a neutron since its birth from fission reaction, transport on materials, until eventually lost due to the absorption reaction or out from the system. The collimator modelling used materials which varied in size in order to generate the value of each of the parameters in accordance with the recommendation of the IAEA, the epithermal neutron flux (ϕepi) > 1.0 x 109n.cm-2s-1, the ratio between the neutron dose rate fast and epithermal neutron flux (Df/ϕepi) < 2.0 x 10-13 Gy.cm2.n-1, the ratio of gamma dose rate and epithermal neutron flux (Dγ/ϕepi) < 2.0 X10-13 Gy.cm2.n-1, the ratio between the thermal and epithermal neutron flux (ϕTh/ϕepi)< 0.05 and the ratio between the current and flux of the epithermal neutron (J/ϕepi) > 0.7. Based on the results of the optimization of the modeling, the materials and sizes of the collimator construction obtained were 0.75 cm Ni as collimator wall, 22 cm Al as a moderator and 4.5 cm Bi as a gamma shield. The outputs of the radiation beam generated from collimator modeling of the radial beam port were ϕepi = 5.25 x 106 n.cm-2.s-1, Df/ϕepi = 1.17 x 10-13Gy.cm2.n-1, Dγ/ϕepi = 1.70 x 10-12 Gy.cm2.n-1, ϕTh/ϕepi = 1.51 and J/ϕepi = 0.731. Based on this study, the result of the beam radiation coming out of the radial beam port dis not fully meet the criteria recommended by IAEA so need to continue this study to get the criteria of IAEA

  17. Accelerator based-boron neutron capture therapy (BNCT)-clinical QA and QC

    International Nuclear Information System (INIS)

    Alpha-particle and recoil Li atom yielded by the reaction (10B, n), due to their high LET properties, efficiently and specifically kill the cancer cell that has incorporated the boron. Efficacy of this boron neutron capture therapy (BNCT) has been demonstrated mainly in the treatment of recurrent head/neck and malignant brain cancers in Kyoto University Research Reactor Institute (KUR). As the clinical trial of BNCT is to start from 2009 based on an accelerator (not on the Reactor), this paper describes the tentative outline of the standard operation procedure of BNCT for its quality assurance (QA) and quality control (QC) along the flow of its clinical practice. Personnel concerned in the practice involve the attending physician, multiple physicians in charge of BNCT, medical physicists, nurses and reactor stuff. The flow order of the actual BNCT is as follows: Pre-therapeutic evaluation mainly including informed consent and confirmation of the prescription; Therapeutic planning including setting of therapy volume, and of irradiation axes followed by meeting for stuffs' agreement, decision of irradiating field in the irradiation room leading to final decision of the axis, CT for the planning, decision of the final therapeutic plan according to Japan Atomic Energy Agency-Computational Dosimetry System (JCDS) and meeting of all related personnel for the final confirmation of therapeutic plan; and BNCT including the transport of patient to KUR, dripping of boronophenylalanine, setting up of the patient on the machine, blood sampling for pharmacokinetics, boron level measurement for decision of irradiating time, switch on/off of the accelerator, confirmation of patient's movement in the irradiated field after the neutron irradiation, blood sampling for confirmation of the boron level, and patient's leave from the room. The QA/QC check is principally to be conducted with the two-person rule. The purpose of the clinical trial is to establish the usefulness of BNCT, and

  18. Boron Neutron Capture Therapy (BNCT) in an experimental model of lung metastases in BDIX rats

    International Nuclear Information System (INIS)

    Boron Neutron Capture Therapy (BNCT) in an experimental model of lung metastases in BDIX rats Introduction: Boron Neutron Capture Therapy (BNCT) is based on selective tumor uptake of boron compounds, followed by neutron irradiation. BNCT was proposed for the treatment of unresectable, diffuse lung metastases. The aim of the present study was to perform BNCT studies in an experimental model of lung metastases. Materials and Methods: 3 x 106/0.5 ml colon carcinoma cells (DHD/K12/TRb) were injected iv in syngeneic BDIX rats. Three weeks post-inoculation, rats with diffuse lung metastases were used for in vivo BNCT studies in the RA-3 Nuclear Reactor. Based on previous biodistribution studies and computational dosimetry with Monte Carlo simulation, 2 doses were prescribed, i.e. 4 Gy and 8 Gy minimum absorbed dose to tumor. The animals were assigned to 5 experimental groups (n= 4 to 8) at each dose level: T0 (euthanized pre-treatment), BPA-BNCT, Comb-BNCT (BPA+GB-10), Beam only (background dose) and Sham (same manipulation, no treatment). Boron concentration was measured in a blood sample taken pre-irradiation to verify that the value was in the range established in previous biodistribution studies. The animals were followed clinically for 2 weeks after neutron irradiation and then euthanized to assess the response of tumor and normal lung, macroscopically and histologically. To date we have evaluated the end-point weight of lung (normal lung + metastases) and % lung weight/body weight as an indicator of tumor growth. Results: The statistical analysis (ANOVA) of % lung weight/body weight showed statistically significant differences (p<0.05) between groups T0 (0.79 ± 0.38) and Sham (1.87 ± 0.91). No statistically significant differences were observed between the Beam only groups (at both dose levels) and Sham. Similar and statistically significant tumor control was induced in the groups BPA-BNCT Low dose (LD) (0.56 ± 0.11), BPA-BNCT High dose (HD) (0.80 ± 0.16), Comb

  19. The combined effect of electroporation and borocaptate in boron neutron capture therapy for murine solid tumors

    International Nuclear Information System (INIS)

    10B-Enriched borocaptate (BSH) was administered intraperitoneally to SCCVII tumor-bearing C3H/He mice. Electroporation (EP) was conducted by using a tweezers-type electrode. The 10B contents in tumors were measured by prompt γ-ray spectrometry. The colony formation assay was applied to investigate the antitumor effects of boron neutron capture therapy (BNCT) and thereby to estimate the intratumor localization of BSH. The 10B concentrations in tumors decreased with time following BSH administration, falling to 5.4(±0.1) ppm at 3 h, whereas EP treatment (3 repetitions) 15 min after BSH injection delayed the clearance of BSH from tumors, and the 10B level remained at 19.4(±0.9) ppm at 3 h. The effect of BNCT increased with the 10B concentration in tumors, and the combination with EP showed a remarkably large cell killing effect even at 3 h after BSH injection. The effect of BNCT, i.e., slope coefficient of the cell survival curve of tumors, without EP was proportional to tumor 10B level (r=0.982), and that of BSH-BNCT combined with EP lay close to the same correlation line. However, tumors subjected to EP after BSH injection did not show high radiosensitivity when irradiated after conversion to a single cell suspension by enzymatic digestion. This indicates that the increase of the BNCT effect by EP was a consequence of enclosure of BSH in the interstitial space of tumor tissue and not within tumor cells. This is different from a previous in vitro study. The combination of EP and BNCT may be clinically useful, if a procedure to limit EP to the tumor region becomes available or if an alternative similar method is employed. (author)

  20. Antiproliferative effect and apoptosis induction in melanoma treatment by boron neutron capture therapy (BCNT)

    Energy Technology Data Exchange (ETDEWEB)

    Faiao-Flores, Fernanda; Coelho, Paulo; Arruda-Neto, Joao; Maria, Durvanei [University of Sao Paulo (USP), SP (Brazil)

    2011-07-01

    Full text: Introduction: Boron neutron capture therapy (BNCT) is an experimental radiotherapy where a compound having {sup 10}B is administered to cancer patients and is accumulated in tumor tissues. Thus, the tumor is irradiated with thermal neutrons, {sup 10}B absorbs and destroys them, producing alpha radiation. Boronophenylalanine (BPA) is the agent responsible for delivering boron to the tumor tissue. After BPA administration, BNCT is used as a localized radiotherapy for many tumors treatment, mainly melanoma, which has a high mortality rate among all types of tumors. The aim of this study was to evaluate in vitro antiproliferative and antitumor effects of BNCT application in human melanoma treatment. Materials and Methods: MEWO cells (human melanoma) were cultured and treated with different concentrations of BPA (8.36 to 0.52 mg/ml). After 90 minutes, they were irradiated with thermal neutron flux up to a dose of 8.4 Gy. The parameters analyzed were free radical production, cell cycle progression, cell death signaling pathways, cycling D1, caspase-3 and extracellular matrix synthesis produced, beyond the mitochondrial electric potential analysis. Results: After BNCT treatment, MEWO cells showed an amount of free radical increase about 10 times. Still, there was a significant decrease of cyclin D1, G0/G1 proliferation, synthesis and G2/M cell cycle phases. BNCT induced a mitochondrial electrical potential decrease, as well as fibrillar proteins of extracellular matrix. BNCT had a significant number of dead cell increase, mainly by necrosis. However, BNCT induced phosphorylated caspase 3 increase. Discussion/Conclusion: BNCT induced cell death increase by necrosis, mitochondrial electric potential decrease and free radical production increase. BNCT is cytotoxic to melanoma cells. Besides necrosis, phosphorylated caspase 3 increase was observed, accompanied by a proliferative response decrease regulated by the G1/S checkpoint and matrix extracellular synthesis

  1. Growth inhibition of human pancreatic cancer grafts in nude mice by boron neutron capture therapy

    International Nuclear Information System (INIS)

    Cell destruction in boron neutron capture therapy (BNCT) is due to the nuclear reaction between 10B and thermal neutrons to release alpha-particles (4He) and lithium-7 ions (7Li). The 4He kills cells in the range of 10 μm from the site of 4He generation. Therefore, it is theoretically possible to kill tumor cells without affecting adjacent healthy tissues, if 10B-compounds could be selectively delivered. We have described that 10B atoms delivered by immunoliposomes exerted cytotoxic effect on human pancreatic carcinoma cells (AsPC-1) in a dose-dependent manner by thermal neutron irradiation in vitro as reported previously. In the present study, the cytotoxic effect of a locally injected 10B compound solution or multilamellar liposomes containing a 10B compound to human pancreatic carcinoma xenograft in nude mice was evaluated after thermal neutron irradiation. AsPC-1 cells (1 x 107) injected subcutaneously into a nude mouse grew to a tumor weighing 100-300 mg after 2 weeks. At this time 200 μg 10B compounds was locally injected in the tumor and irradiated with 2 x 1012 n/cm2 thermal neutron. Tumor growth of 10B-treated groups was suppressed as compared with control group. Histopathologically, hyalinization and necrosis were found in the tumor tissues. For effective tumor destruction, 10B dose more than 60 μg was necessary. The tumor tissue injected with saline only and irradiated showed neither destruction nor necrosis. These data indicate that the accumulation of 10B atoms to the tumor site is mandatory for the cytotoxic effect by thermal neutron irradiation. (author)

  2. Dosimetric analysis of BNCT - Boron Neutron Capture Therapy - coupled to 252Cf brachytherapy

    International Nuclear Information System (INIS)

    The incidence of brain tumors is increasing in world population; however, the treatments employed in this type of tumor have a high rate of failure and in some cases have been considered palliative, depending on histology and staging of tumor. Its necessary to achieve the control tumor dose without the spread irradiation cause damage in the brain, affecting patient neurological function. Stereotactic radiosurgery is a technique that achieves this; nevertheless, other techniques that can be used on the brain tumor control must be developed, in order to guarantee lower dose on health surroundings tissues other techniques must be developing. The 252Cf brachytherapy applied to brain tumors has already been suggested, showing promising results in comparison to photon source, since the active source is placed into the tumor, providing greater dose deposition, while more distant regions are spared. BNCT - Boron Neutron Capture Therapy - is another technique that is in developing to brain tumors control, showing theoretical superiority on the rules of conventional treatments, due to a selective irradiation of neoplasics cells, after the patient receives a borate compound infusion and be subjected to a epithermal neutrons beam. This work presents dosimetric studies of the coupling techniques: BNCT with 252Cf brachytherapy, conducted through computer simulation in MCNP5 code, using a precise and well discretized voxel model of human head, which was incorporated a representative Glioblastoma Multiform tumor. The dosimetric results from MCNP5 code were exported to SISCODES program, which generated isodose curves representing absorbed dose rate in the brain. Isodose curves, neutron fluency, and dose components from BNCT and 252Cf brachytherapy are presented in this paper. (author)

  3. An international dosimetry exchange for boron neutron capture therapy. Part I: Absorbed dose measurements.

    Science.gov (United States)

    Binns, P J; Riley, K J; Harling, O K; Kiger, W S; Munck af Rosenschöld, P M; Giusti, V; Capala, J; Sköld, K; Auterinen, I; Serén, T; Kotiluoto, P; Uusi-Simola, J; Marek, M; Viererbl, L; Spurny, F

    2005-12-01

    An international collaboration was organized to undertake a dosimetry exchange to enable the future combination of clinical data from different centers conducting neutron capture therapy trials. As a first step (Part I) the dosimetry group from the Americas, represented by MIT, visited the clinical centers at Studsvik (Sweden), VTT Espoo (Finland), and the Nuclear Research Institute (NRI) at Rez (Czech Republic). A combined VTT/NRI group reciprocated with a visit to MIT. Each participant performed a series of dosimetry measurements under equivalent irradiation conditions using methods appropriate to their clinical protocols. This entailed in-air measurements and dose versus depth measurements in a large water phantom. Thermal neutron flux as well as fast neutron and photon absorbed dose rates were measured. Satisfactory agreement in determining absorbed dose within the experimental uncertainties was obtained between the different groups although the measurement uncertainties are large, ranging between 3% and 30% depending upon the dose component and the depth of measurement. To improve the precision in the specification of absorbed dose amongst the participants, the individually measured dose components were normalized to the results from a single method. Assuming a boron concentration of 15 microg g(-1) that is typical of concentrations realized clinically with the boron delivery compound boronophenylalanine-fructose, systematic discrepancies in the specification of the total biologically weighted dose of up to 10% were apparent between the different groups. The results from these measurements will be used in future to normalize treatment plan calculations between the different clinical dosimetry protocols as Part II of this study. PMID:16475772

  4. Development of the JAERI computational dosimetry system (JCDS) for boron neutron capture therapy. Cooperative research

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya; Uchiyama, Junzo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Matsumura, Akira; Yamamoto, Tetsuya; Nose, Tadao [Tsukuba Univ., Tsukuba, Ibaraki (Japan); Nakagawa, Yoshinobu [National Sanatorium Kagawa-Children' s Hospital, Kagawa (Japan); Kageji, Teruyoshi [Tokushima Univ., Tokushima (Japan)

    2003-03-01

    The Neutron Beam Facility at JRR-4 enables us to carry out boron neutron capture therapy with epithermal neutron beam. In order to make treatment plans for performing the epithermal neutron beam BNCT, it is necessary to estimate radiation doses in a patient's head in advance. The JAERI Computational Dosimetry System (JCDS), which can estimate distributions of radiation doses in a patient's head by simulating in order to support the treatment planning for epithermal neutron beam BNCT, was developed. JCDS is a software that creates a 3-dimentional head model of a patient by using CT and MRI images, and that generates a input data file automatically for calculation of neutron flux and gamma-ray dose distributions in the brain with the Monte Carlo code MCNP, and that displays these dose distributions on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By using CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal in the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System which can support to set the patient to an actual irradiation position swiftly and accurately. This report describes basic design of JCDS and functions in several processing, calculation methods, characteristics and performance of JCDS. (author)

  5. A benchmark analysis of radiation flux distribution for Boron Neutron Capture Therapy of canine brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Moran, J.M.

    1992-02-01

    Calculations of radiation flux and dose distributions for Boron Neutron Capture Therapy (BNCT) of brain tumors are typically performed using sophisticated three-dimensional analytical models based on either a homogeneous approximation or a simplified few-region approximation to the actual highly-heterogeneous geometry of the irradiation volume. Such models should be validated by comparison with calculations using detailed models in which all significant macroscopic tissue heterogeneities and geometric structures are explicitly represented as faithfully as possible. This work describes a validation exercise for BNCT of canine brain tumors. Geometric measurements of the canine anatomical structures of interest for this work were performed by dissecting and examining two essentially identical Labrador Retriever heads. Chemical analyses of various tissue samples taken during the dissections were conducted to obtain measurements of elemental compositions for tissues of interest. The resulting geometry and tissue composition data were then used to construct a detailed heterogeneous calculational model of the Labrador Retriever head. Calculations of three-dimensional radiation flux distributions pertinent to BNCT were performed for the model using the TORT discrete-ordinates radiation transport code. The calculations were repeated for a corresponding volume-weighted homogeneous tissue model. Comparison of the results showed that the peak neutron and photon flux magnitudes were quite similar for the two models (within 5%), but that the spatial flux profiles were shifted in the heterogeneous model such that the fluxes in some locations away from the peak differed from the corresponding fluxes in the homogeneous model by as much as 10-20%. Differences of this magnitude can be therapeutically significant, emphasizing the need for proper validation of simplified treatment planning models.

  6. Three-dimensional radiation dose distribution analysis for boron neutron capture therapy

    International Nuclear Information System (INIS)

    This paper reports that calculation of physically realistic radiation dose distributions for boron neutron capture therapy (BNCT) is a complex, three-dimensional problem. Traditional one-dimensional (slab) and two-dimensional (cylindrical) models, while useful for neutron beam design and performance analysis, do not provide sufficient accuracy for actual clinical use because the assumed symmetries inherent in such models do not ordinarily exist in the real world. Fortunately, however, it is no longer necessary to make these types of simplifying assumptions. Recent dramatic advances in computing technology have brought full three-dimensional dose distribution calculations for BNCT into the realm of practicality for a wide variety of routine applications. Once a geometric model and the appropriate material compositions have been determined, either stochastic (Monte Carlo) or deterministic calculations of all dose components of interest can now be performed more rapidly and inexpensively for the true three-dimensional geometries typical of actual clinical applications of BNCT. Demonstrations of both Monte Carlo and Deterministic techniques for performing three-dimensional dose distribution analysis for BNCT are provided. Calculated results are presented for a three-dimensional Lucite canine-head phantom irradiated in the epithermal neutron beam available at the Brookhaven Medical Research Reactor. The deterministic calculations are performed using the three-dimensional discrete ordinates method. The Monte Carlo calculations employ a novel method for obtaining spatially detailed radiation flux and dose distributions without the use of flux-at-a-point estimators. The calculated results are in good agreement with each other and with thermal neutron flux measurements taken using copper-gold flux wires placed at various locations in the phantom

  7. Application of HVJ envelope system to boron neutron capture therapy (BNCT)

    International Nuclear Information System (INIS)

    Boron Neutron Capture Therapy (BNCT) has been used clinically for the treatment of malignant tumors. Two drugs, p-boronophenylalanine (BPA) and sulfhydral borane (BSH), have been used as boron delivery agents. These drugs seem to be taken up preferentially in solid tumors, but it is uncertain whether therapeutic quantities of boron atoms are taken up by micro-invasive or distant tumor cells. High accumulation and high selective delivery of boron into tumor tissues are the most important requirements to achieve efficient BNCT for malignant tumor. The HVJ envelope (HVJ-E) vector system is a novel fusion-mediated gene delivery system based on inactivated hemagglutinating virus of Japan (HVJ; Sendai virus). Although we developed this vector system for gene transfer, it can also deliver proteins, synthetic oligonucleotides, and drugs. HVJ-liposome, which is liposome fused with HVJ-E, has higher boron trapping efficiency than HVJ-E alone. We report the boron delivery into cultured cells with HVJ-liposome systems. The cellular 10B concentration after 60 min incubation with HVJ-E containing BSH was 24.9 μg/g cell pellet for BHK-21 cells (baby hamster kidney cells) and 19.4 μg/g cell pellet for SCC VII cells (murine squamous cell carcinoma). These concentrations are higher than that of 60 min incubated cells with BSH containing (100μg 10B/ml) medium. These results indicate the HVJ-E fused with tumor cell membrane and rapidly delivered boron agents, and that the HVJ-E-mediated delivery system could be applicable to BNCT. Plans are underway to begin neutron radiation experiments in vivo and in vitro. (author)

  8. A benchmark analysis of radiation flux distribution for Boron Neutron Capture Therapy of canine brain tumors

    International Nuclear Information System (INIS)

    Calculations of radiation flux and dose distributions for Boron Neutron Capture Therapy (BNCT) of brain tumors are typically performed using sophisticated three-dimensional analytical models based on either a homogeneous approximation or a simplified few-region approximation to the actual highly-heterogeneous geometry of the irradiation volume. Such models should be validated by comparison with calculations using detailed models in which all significant macroscopic tissue heterogeneities and geometric structures are explicitly represented as faithfully as possible. This work describes a validation exercise for BNCT of canine brain tumors. Geometric measurements of the canine anatomical structures of interest for this work were performed by dissecting and examining two essentially identical Labrador Retriever heads. Chemical analyses of various tissue samples taken during the dissections were conducted to obtain measurements of elemental compositions for tissues of interest. The resulting geometry and tissue composition data were then used to construct a detailed heterogeneous calculational model of the Labrador Retriever head. Calculations of three-dimensional radiation flux distributions pertinent to BNCT were performed for the model using the TORT discrete-ordinates radiation transport code. The calculations were repeated for a corresponding volume-weighted homogeneous tissue model. Comparison of the results showed that the peak neutron and photon flux magnitudes were quite similar for the two models (within 5%), but that the spatial flux profiles were shifted in the heterogeneous model such that the fluxes in some locations away from the peak differed from the corresponding fluxes in the homogeneous model by as much as 10-20%. Differences of this magnitude can be therapeutically significant, emphasizing the need for proper validation of simplified treatment planning models

  9. The radiobiology of boron neutron capture therapy: Are ''photon-equivalent'' doses really photon-equivalent?

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) produces a mixture of radiation dose components. The high-linear energy transfer (LET) particles are more damaging in tissue than equal doses of low-LET radiation. Each of the high-LET components can multiplied by an experimentally determined factor to adjust for the increased biological effectiveness and the resulting sum expressed in photon-equivalent units (Gy-Eq). BNCT doses in photon-equivalent units are based on a number of assumptions. It may be possible to test the validity of these assumptions and the accuracy of the calculated BNCT doses by 1) comparing the effects of BNCT in other animal or biological models where the effects of photon radiation are known, or 2) if there are endpoints reached in the BNCT dose escalation clinical trials that can be related to the known response to photons of the tissue in question. The calculated Gy-Eq BNCT doses delivered to dogs and to humans with BPA and the epithermal neutron beam of the Brookhaven Medical Research Reactor were compared to expected responses to photon irradiation. The data indicate that Gy-Eq doses in brain may be underestimated. Doses to skin are consistent with the expected response to photons. Gy-Eq doses to tumor are significantly overestimated. A model system of cells in culture irradiated at various depths in a lucite phantom using the epithermal beam is under development. Preliminary data indicate that this approach can be used to detect differences in the relative biological effectiveness of the beam. The rat 9L gliosarcoma cell survival data was converted to photon-equivalent doses using the same factors assumed in the clinical studies. The results superimposed on the survival curve derived from irradiation with Cs-137 photons indicating the potential utility of this model system. (author)

  10. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy

    OpenAIRE

    Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; Hoshi, Masaharu

    2015-01-01

    Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measuring thermal neutron flux as low as 105 n/cm2/s with sufficient accuracy. The SOF detector will be u...

  11. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy

    OpenAIRE

    Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; Hoshi, Masaharu

    2015-01-01

    Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measuring thermal neutron flux as low as 105 n/cm2/s with sufficient accuracy. The SOF detector ...

  12. Proton nuclear magnetic resonance measurement of p-boronophenylalanine (BPA): A therapeutic agent for boron neutron capture therapy

    OpenAIRE

    Zuo, C. S.; Prasad, P V; Busse, Paul; L. Tang; Zamenhof, R. G.

    1999-01-01

    Noninvasive in vivo quantitation of boron is necessary for obtaining pharmacokinetic data on candidate boronated delivery agents developed for boron neutron capture therapy (BNCT). Such data, in turn, would facilitate the optimization of the temporal sequence of boronated drug infusion and neutron irradiation. Current approaches to obtaining such pharmacokinetic data include: positron emission tomography employing F-18 labeled boronated delivery agents (e.g., p-boronophenylalanine), ex vivo n...

  13. Dose calculation and treatment planning for the Brookhaven NCT Facility

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H.B.; Brugger, R.M.

    1992-01-01

    Consistency of the calculated to measured fluxes and doses in phantoms is important for confidence in treatment planning for Boron Neutron Capture Therapy at the Brookhaven Medical Research Reactor (BMRR). Two phantoms have been used to measure the thermal and epithermal flux and gamma dose distributions for irradiations at the BMRR and these are compared to MCNP calculations. Since MCNP calculations in phantoms or models would be lengthy if the calculations started each time with fission neutrons from the reactor core, a neutron source plane, which was verified by spectrum and flux measurements at the irradiation port, was designed. Measured doses in phantoms are especially important to verify the simulated neutron source plane. Good agreement between the calculated and measured values has been achieved and this neutron source plane is now used to predict flux and dose information for oncologists to form treatment plans as well as designing collimator and room shielding. In addition, a program using MCNP calculated results as input has been developed to predict reliable flux and dose distributions in the central coronal section of a head model for irradiation by the BMRR beam. Dosimetric comparisons and treatment examples are presented.

  14. Dose calculation and treatment planning for the Brookhaven NCT Facility

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H.B.; Brugger, R.M.

    1992-12-31

    Consistency of the calculated to measured fluxes and doses in phantoms is important for confidence in treatment planning for Boron Neutron Capture Therapy at the Brookhaven Medical Research Reactor (BMRR). Two phantoms have been used to measure the thermal and epithermal flux and gamma dose distributions for irradiations at the BMRR and these are compared to MCNP calculations. Since MCNP calculations in phantoms or models would be lengthy if the calculations started each time with fission neutrons from the reactor core, a neutron source plane, which was verified by spectrum and flux measurements at the irradiation port, was designed. Measured doses in phantoms are especially important to verify the simulated neutron source plane. Good agreement between the calculated and measured values has been achieved and this neutron source plane is now used to predict flux and dose information for oncologists to form treatment plans as well as designing collimator and room shielding. In addition, a program using MCNP calculated results as input has been developed to predict reliable flux and dose distributions in the central coronal section of a head model for irradiation by the BMRR beam. Dosimetric comparisons and treatment examples are presented.

  15. Boron neutron capture therapy induces apoptosis of glioma cells through Bcl-2/Bax

    Directory of Open Access Journals (Sweden)

    Mao Xinggang

    2010-12-01

    Full Text Available Abstract Background Boron neutron capture therapy (BNCT is an alternative treatment modality for patients with glioma. The aim of this study was to determine whether induction of apoptosis contributes to the main therapeutic efficacy of BNCT and to compare the relative biological effect (RBE of BNCT, γ-ray and reactor neutron irradiation. Methods The neutron beam was obtained from the Xi'an Pulsed Reactor (XAPR and γ-rays were obtained from [60Co] γ source of the Fourth Military Medical University (FMMU in China. Human glioma cells (the U87, U251, and SHG44 cell lines were irradiated by neutron beams at the XAPR or [60Co] γ-rays at the FMMU with different protocols: Group A included control nonirradiated cells; Group B included cells treated with 4 Gy of [60Co] γ-rays; Group C included cells treated with 8 Gy of [60Co] γ-rays; Group D included cells treated with 4 Gy BPA (p-borono-phenylalanine-BNCT; Group E included cells treated with 8 Gy BPA-BNCT; Group F included cells irradiated in the reactor for the same treatment period as used for Group D; Group G included cells irradiated in the reactor for the same treatment period as used for Group E; Group H included cells irradiated with 4 Gy in the reactor; and Group I included cells irradiated with 8 Gy in the reactor. Cell survival was determined using the 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium (MTT cytotoxicity assay. The morphology of cells was detected by Hoechst33342 staining and transmission electron microscope (TEM. The apoptosis rate was detected by flow cytometer (FCM. The level of Bcl-2 and Bax protein was measured by western blot analysis. Results Proliferation of U87, U251, and SHG44 cells was much more strongly inhibited by BPA-BNCT than by irradiation with [60Co] γ-rays (P 60Co] γ-rays (P P Conclusions Compared with ��-ray and reactor neutron irradiation, a higher RBE can be achieved upon treatment of glioma cells with BNCT. Glioma cell apoptosis induced by

  16. Comparison of the radiobiological effects of Boron neutron capture therapy (BNCT) and conventional Gamma Radiation

    International Nuclear Information System (INIS)

    BNCT is an experimental radiotherapeutic modality that uses the capacity of the isotope 10B to capture thermal neutrons leading to the production of 4He and 7Li, particles with high linear energy transfer (LET). The aim was to evaluate and compare in vitro the mechanisms of response to the radiation arising of BNCT and conventional gamma therapy. We measured the survival cell fraction as a function of the total physical dose and analyzed the expression of p27/Kip1 and p53 by Western blotting in cells of colon cancer (ARO81-1). Exponentially growing cells were distributed into the following groups: 1) BPA (10 ppm 10B) + neutrons; 2) BOPP (10 ppm 10B) + neutrons; 3) neutrons alone; 4) gamma-rays. A control group without irradiation for each treatment was added. The cells were irradiated in the thermal neutron beam of the RA-3 (flux= 7.5 109 n/cm2 sec) or with 60Co (1Gy/min) during different times in order to obtain total physical dose between 1-5 Gy (±10 %). A decrease in the survival fraction as a function of the physical dose was observed for all the treatments. We also observed that neutrons and neutrons + BOPP did not differ significantly and that BPA was the more effective compound. Protein extracts of irradiated cells (3Gy) were isolated to 24 h and 48 h post radiation exposure. The irradiation with neutrons in presence of 10BPA or 10BOPP produced an increase of p53 at 24 h maintain until 48 h. On the contrary, in the groups irradiated with neutrons alone or gamma the peak was observed at 48 hr. The level of expression of p27/Kip1 showed a reduction of this protein in all the groups irradiated with neutrons (neutrons alone or neutrons plus boron compound), being more marked at 24 h. These preliminary results suggest different radiobiological response for high and low let radiation. Future studies will permit establish the role of cell cycle in the tumor radio sensibility to BNCT. (author)

  17. Dynamic infrared imaging of the skin reaction in melanoma patients treated with boron neutron capture therapy

    International Nuclear Information System (INIS)

    As part of the Boron Neutron Capture Therapy (BNCT) project conducted jointly by the Comision Nacional de Energia Atomica and the oncology institute A. Roffo, Argentina, we have recently started a program designed to investigate the ability of dynamic infrared imaging for following-up our cutaneous melanoma patients. BNCT offers a unique opportunity to study the response of the integumentary system to single fractions and high doses of neutrons and heavy ions, providing information that could be potentially important in radiation accidents for people exposed to these kinds of radiation fields. Medical infrared thermography is a non-invasive and functional imaging method, that provides information on the normal and abnormal status and response of the nervous and vascular systems, as well as the local metabolic rate and inflammatory processes that appear as differences in the skin infrared emission. Although it is highly sensitive, it is unspecific, like other conventional imaging techniques. For this reason, infrared thermography must be employed as an adjunct method to other diagnostic procedures and the clinical observation. An infrared camera is employed, with an uncooled ferroelectric focal plane array of 320x240 detector elements, providing a video signal of the infrared emission in the 8-14 μm wavelength band. After patient preparation and acclimation, a basal study of the irradiated region is performed, including high and low dose areas, as well as normal and tumor tissues, and eventually other detectable structures (e.g. scars and veins). Thereafter, a provocation test (a cold stimulus) is applied and the temperature recovery is registered as a function of time. In addition, a 3D computational dosimetry of the irradiated region is performed, which allows a complete representation of the isodose contours mapped onto the 3D reconstruction representing the skin. This reconstruction permits selecting regions of different doses for studying the local response

  18. Design of a plate type fuel based - low power medical reactor for boron neutron capture therapy

    International Nuclear Information System (INIS)

    The interest in the boron neutron capture therapy (BNCT) has been renewed for cancer therapy with some indication of its potential efficacy in recent years. To solve the most important problem that thermal neutrons are attenuated rapidly in tissue due to absorption and scattering, thermal neutron beams are replaced by epithermal neutron beams. Thus, epithermal neutron beams are directed towards a patient's head, during their passage through tissue these neutrons rapidly lose energy by elastic scattering until they end up as thermal neutrons in target tumor volume. The thermal neutrons thus formed, are captured by the 10B atoms which become 11B atoms in the excited state for a very short time 10-12 sec. The 11B atoms then decay producing alpha particles, 7Li recoil nuclei and gamma rays. Tumor cells are killed selectively by the energetic alpha particles and 7Li fission products. We propose a 300kW slab type reactor core having thin and large surface areas so that most of the neutrons emerging from the faces and entering moderator region are fission spectrum neutrons to acquire high intense epithermal neutron beam with high quality. All faces of the slab core, East-West region and North-South region, were considered for epithermal neutron beam collimators. Plate-type U3Si2-Al dispersion fuel having high uranium density is very compatible with composing of a slab type core. The reactor core is loaded with 3.89kg U235 and has the dimension of about 23.46cm width, 31.28cm length and 64.8cm height, with 216 locations to place 204 fuel elements, eight control plates and four safety plates. The general-purpose MCNP 4B code was used to carry out the neutron and photon transport computations. Both keff criticality and fixed source problems were computed. We could reduce at least 7 times long computer time (105 to 140 h in a run) needed to initiate enough neutrons in a run ( 6000 to 8000 cycles in a run with 3000 neutrons per cycle) using the PVM (Parallel Virtual

  19. For boron neutron capture therapy,synthesizing boron-polymer compounds and testing in laboratory conditions

    International Nuclear Information System (INIS)

    The aim of this project is to establish a focus point at Turkish Atomic Energy Authority (TAEA) in the field of Boron Neutron Capture Therapy which is a binary radiotherapy method for brain tumours. Moreover in the scope of the project, a new alternative of 10B-carrier compounds will be synthesized, the neutron source will be determined and the infrastructure to start the clinical trials of BNCT in our country will be established. BNCT is a binary radiotherapy method and the successful of this method is depend on the synthesized boron compounds which have the selective targeting property with tumour cells and neutron optimization. The water-soluble polymer based boron compounds having biochemical and physiological properties will be synthesized and cell culture experiment will be done. In addition, after the neutron source is set up in our country, the infrastructure studies will be started in order to start the clinical trials of BNCT. In this project, there are three different groups as boron compounds, neutron physics and medical group. Neutron physics group is starting the calculations of neutron beam parameters using in BNCT application. But, medical group has no active studies yet. Boron compounds group has been carried out two different experimental studies. In the first experimental study, functional groups have been bound to boron containing polymers to enhance the selectively targeting property and characterized by various analysis methods. Later, cell culture experiment will be done. The first study has been carried out with Hacettepe University. Up to present, completed studies are listed as: -Maleic anhydride oligomer was synthesized and then 2-aminoethyl diphenyl borate (2-AEPB) and monomethoxy poly(ethylene glycol) (PEG) was bound to this oligomer, respectively. Thus, [MAH]n-g1-2-AEPB-g2-PEG was synthesized. -2-AEPB compound were bound to poly(acrylic acid) polymer at different three mole ratio.Then, the selected Poli(Ac)-g1-2-AEPB polymer was

  20. Boron-Containing Compounds for Liposome-Mediated Tumor Localization and Application to Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hawthorne, M. Frederick [Univ. of California, Los Angeles, CA (United States)

    2005-04-07

    Medical application of boron neutron capture therapy (BNCT) has been significantly hindered by the slow development of boron drug-targeting methodologies for the selective delivery of high boron concentration sto malignant cells. We have successfully sought to fill this need by creating liposomes suitable as in vivo boron delivery vehicles for BNCT. Delivery of therapeutic quantities of boron to tumors in murine models has been achieved with small unilamellar boron-rich liposomes. Subsequently, attempts have been made to improve delivery efficiency of liposomes encapsulating boron-containing water-soluble species into their hollow core by incorporating lipophilic boron compounds as addenda to the liposome bilayer, incorporating boron compounds as structural components of the bilayer (which however, poses the risk of sacrificing some stability), and combinations thereof. Regardless of the method, approximately 90% of the total liposome mass remains therapeutically inactive and comprised of the vehicle's construction materials, while less than 5% is boron for neutron targeting. Following this laboratory's intensive study, the observed tumor specificity of certain liposomes has been attributed to their diminutive size of these liposomes (30-150 nm), which enables these small vesicles to pass through the porous, immature vasculature of rapidly growing tumor tissue. We surmised that any amphiphilic nanoparticle of suitable size could possess some tumor selectivity. Consequently, the discovery of a very boron-rich nanoparticle delivery agent with biodistribution performance similar to unilamellar liposomes became one of our goals. Closomers, a new class of polyhedral borane derivatives, attracted us as an alternative BNCT drug-delivery system. We specifically envisioned dodeca (nido-carboranyl)-substituted closomers as possibly having a great potential role in BNCT drug delivery. They could function as extraordinarily boron-rich BNCT drugs since they are

  1. Boron-Containing Compounds for Liposome-Mediated Tumor Localization and Application to Neutron Capture Therapy

    International Nuclear Information System (INIS)

    Medical application of boron neutron capture therapy (BNCT) has been significantly hindered by the slow development of boron drug-targeting methodologies for the selective delivery of high boron concentration sto malignant cells. We have successfully sought to fill this need by creating liposomes suitable as in vivo boron delivery vehicles for BNCT. Delivery of therapeutic quantities of boron to tumors in murine models has been achieved with small unilamellar boron-rich liposomes. Subsequently, attempts have been made to improve delivery efficiency of liposomes encapsulating boron-containing water-soluble species into their hollow core by incorporating lipophilic boron compounds as addenda to the liposome bilayer, incorporating boron compounds as structural components of the bilayer (which however, poses the risk of sacrificing some stability), and combinations thereof. Regardless of the method, approximately 90% of the total liposome mass remains therapeutically inactive and comprised of the vehicle's construction materials, while less than 5% is boron for neutron targeting. Following this laboratory's intensive study, the observed tumor specificity of certain liposomes has been attributed to their diminutive size of these liposomes (30-150 nm), which enables these small vesicles to pass through the porous, immature vasculature of rapidly growing tumor tissue. We surmised that any amphiphilic nanoparticle of suitable size could possess some tumor selectivity. Consequently, the discovery of a very boron-rich nanoparticle delivery agent with biodistribution performance similar to unilamellar liposomes became one of our goals. Closomers, a new class of polyhedral borane derivatives, attracted us as an alternative BNCT drug-delivery system. We specifically envisioned dodeca (nido-carboranyl)-substituted closomers as possibly having a great potential role in BNCT drug delivery. They could function as extraordinarily boron-rich BNCT drugs since they are amphiphilic

  2. Dosimetry and dose planning in boron neutron capture therapy : Monte Carlo studies

    Energy Technology Data Exchange (ETDEWEB)

    Koivunoro, H.

    2012-07-01

    Boron neutron capture therapy (BNCT) is a biologically targeted radiotherapy modality. So far, 249 cancer patients have received BNCT at the Finnish Research Reactor 1 (FiR 1) in Finland. The effectiveness and safety of radiotherapy are dependent on the radiation dose delivered to the tumor and healthy tissues, and on the accuracy of the doses. At FiR 1, patient dose calculations are performed with the Monte Carlo (MC) -based treatmentplanning system (TPS), Simulation Environment for Radiotherapy Applications (SERA). Initially, BNCT was applied to head and neck cancer, brain tumors, and malignant melanoma. To evaluate the applicability of the new target tumors for BNCT, calculation dosimetry studies are needed. So far, clinical BNCT has been performed with the neutrons from a nuclear reactor, while an accelerator based neutron sources applicable for hospital operation would be preferable. In this thesis, BNCT patient dose calculation practice in Finland was evaluated against reference calculations and experimental data in several cases. Calculations with two TPSs applied in clinical BNCT were compared. The suitability of the deuterium-deuterium (DD) and deuterium-tritium (D-T) fusion reaction-based compact neutron sources for BNCT were evaluated. In addition, feasibility of BNCT for noninvasive liver tumor treatments was examined. The deviation between SERA and the reference calculations was within 4% in the phantoms studied and in a brain cancer patient model elsewhere, except on the phantom or skin surface, for the boron, nitrogen, and photon dose components. These dose components produce 99% of the tumor dose and > 90% of the healthy tissue dose at points of relevance for treatment at the FiR 1 facility. The reduced voxel cell size ({<=} 0.5 cm) in the SERA edit mesh improved calculation accuracy on the surface. The erratic biased fastneutron run option in SERA led to significant underestimation (up to 30-60%) of the fastneutron dose, while more accurate fast

  3. A theoretical model for the production of Ac-225 for cancer therapy by neutron capture transmutation of Ra-226.

    Science.gov (United States)

    Melville, G; Melville, P

    2013-02-01

    Radium needles that were once implanted into tumours as a cancer treatment are now obsolete and constitute a radioactive waste problem, as their half-life is 1600 years. We are investigating the reduction of radium by transmutation by bombarding Ra-226 with high-energy neutrons from a neutron source to produce Ra-225 and hence Ac-225, which can be used as a generator to produce Bi-213 for use in 'Targeted Alpha Therapy' for cancer. This paper examines the possibility of producing Ac-225 by neutron capture using a theoretical model in which neutron energy is convoluted with the corresponding neutron cross sections of Ra-226. The total integrated yield can then be obtained. This study shows that an intense beam of high-energy neutrons could initiate neutron capture on Ra-226 to produce Ra-225 and hence practical amounts of Ac-225 and a useful reduction of Ra-226.

  4. A NEW SINGLE-CRYSTAL FILTERED THERMAL NEUTRON SOURCE FOR NEUTRON CAPTURE THERAPY RESEARCH AT THE UNIVERSITY OF MISSOURI

    Energy Technology Data Exchange (ETDEWEB)

    John D. Brockman; David W. Nigg; M. Frederick Hawthorne

    2008-09-01

    Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The calculated and measured thermal neutron flux produced at the irradiation location is on the order of 9.5x108 neutrons/cm2-s, with a measured cadmium ratio (Au foils) of 105, indicating a well-thermalized spectrum.

  5. Molecular Medicine: Synthesis and In Vivo Detection of Agents for use in Boron Neutron Capture Therapy. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Kabalka, G. W.

    2005-06-28

    The primary objective of the project was the development of in vivo methods for the detection and evaluation of tumors in humans. The project was focused on utilizing positron emission tomography (PET) to monitor the distribution and pharamacokinetics of a current boron neutron capture therapy (BNCT) agent, p-boronophenylalanine (BPA) by labeling it with a fluorine-18, a positron emitting isotope. The PET data was then used to develop enhanced treatment planning protocols. The study also involved the synthesis of new tumor selective BNCTagents that could be labeled with radioactive nuclides for the in vivo detection of boron.

  6. In-phantom dosimetry using the 13C(d,n)14N reaction for BNCT (boron neutron capture therapy)

    International Nuclear Information System (INIS)

    The use of the 13 C(d,n)14 N reaction at Ed =1.5 MeV for accelerator-based boron neutron capture therapy is investigated. The 13 C(d,n)14 N reaction presents the advantages of carbon as a target material and its large cross section. The deuteron beam was produced by a tandem accelerator at MIT's Laboratory for Accelerator Beam Applications. The resulting neutron spectra were evaluated in terms of RBE-dose rates at different depths inside a water-filled brain phantom using a heavy water moderator and lead reflector assembly. All results were simulated using the code MCNP. (author)

  7. Boron neutron capture therapy (BNCT) for glioblastoma multiforme using the epithermal neutron beam at the Brookhaven Medical Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Capala, J. [Brookhaven National Lab., Upton, NY (United States); Diaz, A.Z.; Chadha, M. [Univ. Hospital, State Univ. of New York, NY (United States)] [and others

    1997-12-31

    The abstract describes evaluation of boron neutron capture therapy (BNCT) for two groups of glioblastoma multiforme patients. From September 1994 to February 1996 15 patients have been treated. In September 1997 another 34 patients were examined. Authors determined a safe starting dose for BNCT using epithermal neutrons and BPA-F. They have also evaluated adverse effects of BNCT at this starting dose. Therapeutic effectiveness of this starting dose has been evaluated. No significant side effects from BPA-F infusion or BNCT treatment were observed in normal brains.

  8. Evaluation of carboranylporphyrins as boron delivery agents for neutron capture therapy

    International Nuclear Information System (INIS)

    The goals of the present study were two-fold. First, to determine the biodistribution of three carboranyl-porphyrins, designated H2DCP, H2TCP and H2TBP following intracerebral (i.c.) administration by means of convection enhanced delivery (CED) to F98 glioma bearing rats. Tumor boron concentrations immediately after CED were 36 and 88 μg/g for H2DCP and H2TCP, respectively, and were 103 and 62 μg/g for H2TCP and H2TBP, respectively, 24h after termination of CED. The corresponding normal brain concentrations were 5.2, 3.3 and 0.8 μg/g, and blood and liver concentrations all were 2TCP and H2TBP as boron delivery agents in F98 glioma bearing rats. BNCT was carried out at the Massachusetts Institute of Technology (MIT) Research Reactor (MITRR) 24 h after CED of 200 μl of either 0.5 mg of H2TCP or H2TBP. Untreated control rats all died within 29 days after tumor implantation and had a mean survival time (MST) of 23±3 days and irradiated controls had a MST of 27±3 days. Animals that received H2TCP by CED, followed by BNCT, had a MST of 35±4 days and animals received H2TBP had a MST of 44±10 days. Further studies were carried out using H2TBP at a dose of 0.2 mg administered by a Harvard pump, either alone or in combination with i.v. BPA, and the corresponding MSTs were 34±3 d and 43±9 d, respectively. Histopathologic examination of the brains of animals that died revealed large numbers of porphyrin laden macrophages and extracellular accumulations of free porphyrin indicating that tumor cell uptake was suboptimal. Further studies are planned to synthesize and evaluate new compounds that will have enhanced cellular uptake and efficacy as boron delivery agents for NCT. (author)

  9. The relationship between boron neutron capture therapy (BNCT) and positron emission tomography (PET) for malignant brain tumors

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a particle irradiation therapy that is theoretically available for selective radiation of tumor cells. Boronophenylalanine-positron emission tomography (18F-BPA-PET) was used in this study. Boron is used as a tracer compound for the neutron capture reaction and has been particularly useful for the recent noncraniotomy BNCT. In this report, we introduce this type of PET as a principal axis in BNCT and relationship with PET. We calculated the drug accumulation to the tumor before neutron irradiation to individualize the treatment. We decided the indication for BNCT on the basis of a PET study and are now expanding the indications to other systemic cancers, including head and neck, lung, and liver cancers. In addition, other irradiation modalities have developed a radiation plan on the basis of a PET study, and several studies attempted improving the results; however, the lesion is exposed to high radiation doses and appear as high accumulation on BPA-PET during BNCT. We determined the neutron exposure time from the dosage for normal tissue in the actual treatment, but the lesion/normal tissue ratio obtained from BPA-PET is for evaluating the tumor dose and following the treatment plan. We also found that a PET study was useful in the follow-up stage to aid in diagnosis of pathologic conditions such as increase in tumor volume, recurrence, or radiation necrosis and for patients who had already been treated for malignant brain tumor. (author)

  10. Design and preparation of ethyl cellulose microcapsules of gadopentetate dimeglumine for neutron-capture therapy using the Wurster process.

    Science.gov (United States)

    Fukumori, Y; Ichikawa, H; Tokumitsu, H; Miyamoto, M; Jono, K; Kanamori, R; Akine, Y; Tokita, N

    1993-06-01

    Microcapsules of hygroscopic, highly water-soluble gadopentetate dimeglumine (Gd-DTPA-DM) for use in preliminary in vivo experiments for neutron-capture therapy were designed. They were prepared with such properties as a particle size small enough to be suspended and injected through a syringe, a negligible release of Gd-DTPA-DM, and a high drug content by means of the Wurster process, a spray coating method using a spouted bed with a draft tube. They were composed of lactose cores of 53-63 microm, an undercoat of ethyl cellulose (EC) and polyvinylpyrrolidone (PVP), a drug-layer of Gd-DTPA-DM, EC and PVP, a waterproof coat and a release-sustaining overcoat of EC and cholesterol (1:1), and a surface treated with hydrogenated egg lecithin. By curing at 110 degrees C for 30 min after mixing with 20% pulverized mannitol powder, the 20% overcoating suppressed the release of Gd-DTPA-DM from 75-106 microm microcapsules to less than 10% for the first 20 min, which was the period required to prepare a suspension, inject it and irradiate the neutron. The microcapsules could be used to confirm that the intracellular presence of Gd is not critical in gadolinium neutron-capture therapy. PMID:8370113

  11. Conceptual study of a compact accelerator-driven neutron source for radioisotope production, boron neutron capture therapy and fast neutron therapy

    CERN Document Server

    Angelone, M; Rollet, S

    2002-01-01

    The feasibility of a compact accelerator-driven device for the generation of neutron spectra suitable for isotope production by neutron capture, boron neutron capture therapy and fast neutron therapy, is analyzed by Monte Carlo simulations. The device is essentially an extension of the activator proposed by Rubbia left bracket CERN/LHC/97-04(EET) right bracket , in which fast neutrons are diffused and moderated within a properly sized lead block. It is shown that by suitable design of the lead block, as well as of additional elements of moderating and shielding materials, one can generate and exploit neutron fluxes with the spectral features required for the above applications. The linear dimensions of the diffusing-moderating device can be limited to about 1 m. A full-scale device for all the above applications would require a fast neutron source of about 10**1**4 s**-**1, which could be produced by a 1 mA, 30 MeV proton beam impinging on a Be target. The concept could be tested at the Frascati Neutron Gener...

  12. GPU-based prompt gamma ray imaging from boron neutron capture therapy

    International Nuclear Information System (INIS)

    This reaction can be applied to the therapy and diagnosis about the tumor simultaneously. After the compound labeled with the boron is accumulated at the tumor site, the alpha particle induced by the reaction between the thermal neutron and the boron induces tumor cell death. Also, the 478 keV prompt gamma ray is emitted from the same reaction point. If this single prompt photon is detected by single photon emission computed tomography (SPECT), the tomographic image of the therapy region can be monitored during the radiation treatment. However, in order to confirm the therapy region using the image during the treatment, the image needs to be provided promptly. Due to a relatively long acquisition time required to get SPECT images, both reduced number of projections and the fast image reconstruction schemes are needed to provide the images during radiation treatment. The computation time for image reconstruction using the GPU with the modified OSEM algorithm was measured and compared with the computation time using CPU. Through the results, we confirmed the feasibility of the image reconstruction for prompt gamma ray image using GPU for the BNCT. In the further study, the development of the algorithm for faster reconstruction of the prompt gamma ray image during the BNCT using the GPU computation will be conducted. Also, the analysis of the target to background level about the reconstructed image will be performed using the extracted image profile

  13. GPU-based prompt gamma ray imaging from boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Do-Kun; Jung, Joo-Young; Suh, Tae Suk [College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of)

    2015-05-15

    This reaction can be applied to the therapy and diagnosis about the tumor simultaneously. After the compound labeled with the boron is accumulated at the tumor site, the alpha particle induced by the reaction between the thermal neutron and the boron induces tumor cell death. Also, the 478 keV prompt gamma ray is emitted from the same reaction point. If this single prompt photon is detected by single photon emission computed tomography (SPECT), the tomographic image of the therapy region can be monitored during the radiation treatment. However, in order to confirm the therapy region using the image during the treatment, the image needs to be provided promptly. Due to a relatively long acquisition time required to get SPECT images, both reduced number of projections and the fast image reconstruction schemes are needed to provide the images during radiation treatment. The computation time for image reconstruction using the GPU with the modified OSEM algorithm was measured and compared with the computation time using CPU. Through the results, we confirmed the feasibility of the image reconstruction for prompt gamma ray image using GPU for the BNCT. In the further study, the development of the algorithm for faster reconstruction of the prompt gamma ray image during the BNCT using the GPU computation will be conducted. Also, the analysis of the target to background level about the reconstructed image will be performed using the extracted image profile.

  14. Determination of boron in biological samples for the needs of neutron capture therapy

    International Nuclear Information System (INIS)

    Monitoring the actual concentration of 10B in a patient's blood is a prerequisite for determining the start and length of patient irradiation. The Prompt Gamma Ray Analysis (PGRA) method enables this nuclide to be determined rapidly and reliably within the region of 1 to 100 ppm. In this method, the characteristic line at 478 keV from the nuclear reaction 10B+n → 7Li+α+γ during sample exposure to thermal neutrons is used to determine boron. The facility which has been built up for this purpose comprises, in particular, a large-volume semiconductor detector for recording gamma rays emerging from the radiative neutron capture on the target

  15. Functionalization and cellular uptake of boron carbide nanoparticles. The first step toward T cell-guided boron neutron capture therapy.

    Science.gov (United States)

    Mortensen, M W; Björkdahl, O; Sørensen, P G; Hansen, T; Jensen, M R; Gundersen, H J G; Bjørnholm, T

    2006-01-01

    In this paper we present surface modification strategies of boron carbide nanoparticles, which allow for bioconjugation of the transacting transcriptional activator (TAT) peptide and fluorescent dyes. Coated nanoparticles can be translocated into murine EL4 thymoma cells and B16 F10 malignant melanoma cells in amounts as high as 0.3 wt. % and 1 wt. %, respectively. Neutron irradiation of a test system consisting of untreated B16 cells mixed with B16 cells loaded with boron carbide nanoparticles were found to inhibit the proliferative capacity of untreated cells, showing that cells loaded with boron-containing nanoparticles can hinder the growth of neighboring cells upon neutron irradiation. This could provide the first step toward a T cell-guided boron neutron capture therapy.

  16. IMPROVED COMPUTATIONAL CHARACTERIZATION OF THE THERMAL NEUTRON SOURCE FOR NEUTRON CAPTURE THERAPY RESEARCH AT THE UNIVERSITY OF MISSOURI

    Energy Technology Data Exchange (ETDEWEB)

    Stuart R. Slattery; David W. Nigg; John D. Brockman; M. Frederick Hawthorne

    2010-05-01

    Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The computational models used for the final beam design and performance evaluation are based on coupled discrete-ordinates and Monte Carlo techniques that permit detailed modeling of the neutron transmission properties of the filtering crystals with very few approximations. This is essential for detailed dosimetric studies required for the anticipated research program.

  17. Correlation between radiation dose and histopathological findings in patients with gliblastoma treated with boron neutron capture therapy (BNCT)

    International Nuclear Information System (INIS)

    The purpose of this study was to clarify the correlation between the radiation dose and histopathological findings in patients with glioblastoma multiforme (GBM) treated with boron neutron capture therapy (BNCT). Histopathological studies were performed on specimens from 8 patients, 3 had undergone salvage surgery and 5 were autopsied. For histopathological cure of GBM at the primary site, the optimal minimal dose to the gross tumor volume (GTV) and the clinical target volume (CTV) were 68 Gy(w) and 44 Gy(w), respectively. - Highlights: • It is very important to determine the curable BNCT radiation dose on histopathological aspect in BNCT. • Of 23 patients with GBM treated with BNCT, autopsy was performed in 5, salvage surgery in 3, and histopathological study in 8. • To achieve the histopathological cure of GBM at the primary site, the optimal minimal dose to the GTV and CTV was 68 Gy(w) and 44 Gy(w), respectively

  18. A Small-Animal Irradiation Facility for Neutron Capture Therapy Research at the RA-3 Research Reactor

    International Nuclear Information System (INIS)

    The National Atomic Energy Commission of Argentina (CNEA) has constructed a thermal neutron source for use in Boron Neutron Capture Therapy (BNCT) applications at the RA-3 research reactor facility located in Buenos Aires. The Idaho National Laboratory (INL) and CNEA have jointly conducted some initial neutronic characterization measurements for one particular configuration of this source. The RA-3 reactor (Figure 1) is an open pool type reactor, with 20% enriched uranium plate-type fuel and light water coolant. A graphite thermal column is situated on one side of the reactor as shown. A tunnel penetrating the graphite structure enables the insertion of samples while the reactor is in normal operation. Samples up to 14 cm height and 15 cm width are accommodated

  19. Experimental and Simulated Characterization of a Beam Shaping Assembly for Accelerator- Based Boron Neutron Capture Therapy (AB-BNCT)

    International Nuclear Information System (INIS)

    In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the 7Li(p, n)7Be reaction by irradiating a thick LiF target with a 2.3 MeV proton beam delivered by the TANDAR accelerator at CNEA. The emerging neutron flux was measured by means of activation foils while the beam quality and directionality was evaluated by means of Monte Carlo simulations. The parameters show compliance with those suggested by IAEA. Finally, an improvement adding a beam collimator has been evaluated.

  20. Optimal timing of neutron irradiation for boron neutron capture therapy after intravenous infusion of sodium borocaptate in patients with glioblastoma

    International Nuclear Information System (INIS)

    Purpose: A cooperative study in Europe and Japan was conducted to determine the pharmacokinetics and boron uptake of sodium borocaptate (BSH: Na2B12H11SH), which has been introduced clinically as a boron carrier for boron neutron capture therapy in patients with glioblastoma. Methods and Materials: Data from 56 patients with glioblastoma who received BSH intravenous infusion were retrospectively reviewed. The pharmacokinetics were evaluated in 50 patients, and boron uptake was investigated in 47 patients. Patients received BSH doses between 12 and 100 mg/kg of body weight. For the evaluation, the infused boron dose was scaled linearly to 100 mg/kg BSH. Results: In BSH pharmacokinetics, the average value for total body clearance, distribution volume of steady state, and mean residence time was 3.6±1.5 L/h, 223.3±160.7 L, and 68.0±52.5 h, respectively. The average values of the boron concentration in tumor adjusted to 100 mg/kg BSH, the boron concentration in blood adjusted to 100 mg/kg BSH, and the tumor/blood boron concentration ratio were 37.1±35.8 ppm, 35.2±41.8 ppm, and 1.53±1.43, respectively. A good correlation was found between the logarithmic value of Tadj and the interval from BSH infusion to tumor tissue sampling. About 12-19 h after infusion, the actual values for Tadj and tumor/blood boron concentration ratio were 46.2±36.0 ppm and 1.70±1.06, respectively. The dose ratio between tumor and healthy tissue peaked in the same interval. Conclusion: For boron neutron capture therapy using BSH administered by intravenous infusion, this work confirms that neutron irradiation is optimal around 12-19 h after the infusion is started

  1. Dosimetry and stability studies of the boron neutron capture therapy agent F-BPA-Fr using PET and MRI

    Science.gov (United States)

    Dyke, Jonathan Paul

    The treatment of deep seated brain tumors such as glioblastoma Multiforme has been unsuccessful for many patients. Surgical debulking, chemotherapy and standard radiotherapy have met with limited success. Boron neutron capture therapy offers a binary mode brachytherapy based on the following capture reaction that may provide an innovative alternative to standard forms of treatment:10B + n /to/ 11B /to 7Li + 4He + 2.31 MeVBoron is chemically attached to a tumor binding compound creating a non-toxic neutron absorber. A dose of epithermal neutrons provides the catalyst to produce the lithium and alpha particles which destroy any tissue within a length of one cell diameter from the boron compound. This dissertation uses 19F-MRI and 18F-PET to provide answers to the localization and biodistribution questions that arise in such a treatment modality. Practical patient dosimetry and actual treatment planning using the PET data is also examined. Finally, theoretical work done in the areas of compartmental modelling dealing with pharmacokinetic uptake of the PET radiotracer and dose analysis in microdosimetry is also presented.

  2. Development and in vitro testing of liposomal gadolinium-formulations for neutron capture therapy of glioblastoma multiforme

    International Nuclear Information System (INIS)

    For the improvement of current neutron capture therapy, several liposomal formulations of neutron capture agent gadolinium were developed and tested in a glioma cell model. Formulations were analyzed regarding physicochemical and biological parameters, such as size, zeta potential, uptake into cancer cells and performance under neutron irradiation. The neutron and photon dose derived from intracellular as well as extracellular Gd was calculated via Monte Carlo simulations and set in correlation with the reduction of cell survival after irradiation. To investigate the suitability of Gd as a radiosensitizer for photon radiation, cells were also irradiated with synchrotron radiation in addition to clinically used photons generated by linear accelerator. Irradiation with neutrons led to significantly lower survival for Gd-liposome-treated F98 and LN229 cells, compared to irradiated control cells and cells treated with non-liposomal Gd-DTPA. Correlation between Gd-content and -dose and respective cell survival displayed proportional relationship for most of the applied formulations. Photon irradiation experiments showed the proof-of-principle for the radiosensitizer approach, although the photon spectra currently used have to be optimized for higher efficiency of the radiosensitizer. In conclusion, the newly developed Gd-liposomes show great potential for the improvement of radiation treatment options for highly malignant glioblastoma.

  3. Considerations for boron neutron capture therapy studies; Consideracoes sobre o estudo da BNCT (terapia de captura neutronica por boro)

    Energy Technology Data Exchange (ETDEWEB)

    Faria Gaspar, P. de

    1994-12-31

    Radiotherapy is indispensable as a mean to eradicate deeply or infiltrating tumor tissue that can not be removed surgically. Therefore, it is not selective and may also kill the surrounding health tissue. The principle of BNCT (Boron Neutron Capture Therapy) consist in targeting a tumor selectively with a boron-10 compound. This nuclide has a large capture cross section for thermal neutrons and the nuclear reaction and the delivered energy in locus will selective the tumor. Since its initial proposal in 1963 BNCT has made much progress, however it is not used in a routine treatment. In this work it was approached some complex procedures, as the obtention of selective boron compounds, the adequate set up of neutron beams, the biodistribution, the in vivo and in vitro studies, and also human patients treatments. This work provide fundamentals about BNCT to professional of different areas of knowledge since it comprises multidisciplinary study. It includes appendixes for the ones not related to the field for a better comprehension of the many aspects involved. It is also presented a glossary containing technical and basic aspects involved. It is also presented a glossary containing technical and basic terms referred in the work. (author). 174 refs, 1 fig, 12 apps.

  4. Investigation of current status in Europe and USA on boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-11-01

    This report describes on the spot investigation results of current status of medical irradiation in Europe and USA at Feb. 1999. In HFR (Netherlands), the phase 1 study with the Joint Research Centre (JRC) of the EU had been already finished in those days, at the same time, an improvement of medical irradiation field of VTT(Finland) had been finishing and then clinical trial research had been about to start. On the other hand, phase 1 studies by two groups of BNL (Brook heaven National Laboratory) and MIT (Nuclear Engineering of Massachusetts Institute of Technology) in US were now in almost final stage, and they would start on phase 2 study. Either reactors of MIT and BNL were in modification to increase neutron flux, especially that employing fission converter into the irradiation facility and installation of irradiation room were carrying out in the former. In Europe and USA, the accelerator-based BNCT planes are now in progress vigorously, and will have reality. A reform of dynamitron accelerator at University of Birmingham was progressed, and the clinical treatment would be started from September 2000. The accelerator group at MIT has a small type of tandem accelerator, and they were performing basic experiment for BNCS (Boron Neutron Capture Synovectomy) with this accelerator. The concept design for an accelerator and a moderator had been finished at Lawrence Berkeley National Laboratory and University of Berkeley. (author)

  5. Investigation of current status in Europe and USA on boron neutron capture therapy

    International Nuclear Information System (INIS)

    This report describes on the spot investigation results of current status of medical irradiation in Europe and USA at Feb. 1999. In HFR (Netherlands), the phase 1 study with the Joint Research Centre (JRC) of the EU had been already finished in those days, at the same time, an improvement of medical irradiation field of VTT(Finland) had been finishing and then clinical trial research had been about to start. On the other hand, phase 1 studies by two groups of BNL (Brook heaven National Laboratory) and MIT (Nuclear Engineering of Massachusetts Institute of Technology) in US were now in almost final stage, and they would start on phase 2 study. Either reactors of MIT and BNL were in modification to increase neutron flux, especially that employing fission converter into the irradiation facility and installation of irradiation room were carrying out in the former. In Europe and USA, the accelerator-based BNCT planes are now in progress vigorously, and will have reality. A reform of dynamitron accelerator at University of Birmingham was progressed, and the clinical treatment would be started from September 2000. The accelerator group at MIT has a small type of tandem accelerator, and they were performing basic experiment for BNCS (Boron Neutron Capture Synovectomy) with this accelerator. The concept design for an accelerator and a moderator had been finished at Lawrence Berkeley National Laboratory and University of Berkeley. (author)

  6. Boron neutron capture therapy induces cell cycle arrest and cell apoptosis of glioma stem/progenitor cells in vitro

    International Nuclear Information System (INIS)

    Glioma stem cells in the quiescent state are resistant to clinical radiation therapy. An almost inevitable glioma recurrence is due to the persistence of these cells. The high linear energy transfer associated with boron neutron capture therapy (BNCT) could kill quiescent and proliferative cells. The present study aimed to evaluate the effects of BNCT on glioma stem/progenitor cells in vitro. The damage induced by BNCT was assessed using cell cycle progression, apoptotic cell ratio and apoptosis-associated proteins expression. The surviving fraction and cell viability of glioma stem/progenitor cells were decreased compared with differentiated glioma cells using the same boronophenylalanine pretreatment and the same dose of neutron flux. BNCT induced cell cycle arrest in the G2/M phase and cell apoptosis via the mitochondrial pathway, with changes in the expression of associated proteins. Glioma stem/progenitor cells, which are resistant to current clinical radiotherapy, could be effectively killed by BNCT in vitro via cell cycle arrest and apoptosis using a prolonged neutron irradiation, although radiosensitivity of glioma stem/progenitor cells was decreased compared with differentiated glioma cells when using the same dose of thermal neutron exposure and boronophenylalanine pretreatment. Thus, BNCT could offer an appreciable therapeutic advantage to prevent tumor recurrence, and may become a promising treatment in recurrent glioma

  7. From radiation-induced chromosome damage to cell death: modelling basic mechanisms and applications to boron neutron capture therapy.

    Science.gov (United States)

    Ballarini, F; Bortolussi, S; Clerici, A M; Ferrari, C; Protti, N; Altieri, S

    2011-02-01

    Cell death is a crucial endpoint in radiation-induced biological damage: on one side, cell death is a reference endpoint to characterise the action of radiation in biological targets; on the other side, any cancer therapy aims to kill tumour cells. Starting from Lea's target theory, many models have been proposed to interpret radiation-induced cell killing; after briefly discussing some of these models, in this paper, a mechanistic approach based on an experimentally observed link between chromosome aberrations and cell death was presented. More specifically, a model and a Monte Carlo code originally developed for chromosome aberrations were extended to simulate radiation-induced cell death applying an experimentally observed one-to-one relationship between the average number of 'lethal aberrations' (dicentrics, rings and deletions) per cell and -ln S, S being the fraction of surviving cells. Although such observation was related to X rays, in the present work, the approach was also applied to protons and alpha particles. A good agreement between simulation outcomes and literature data provided a model validation for different radiation types. The same approach was then successfully applied to simulate the survival of cells enriched with boron and irradiated with thermal neutrons at the Triga Mark II reactor in Pavia, to mimic a typical treatment for boron neutron capture therapy. PMID:21159746

  8. Clinical trial of neutron capture therapy for brain tumors at New England Medical Center and the Massachusetts Institute of Technology

    International Nuclear Information System (INIS)

    A proposal is submitted that is based on the conclusions of a NCT expert panel recently convened at BNL by the Department of Energy to evaluate the status of NCT and to recommend what preclinical tasks should be accomplished prior to a clinical study being undertaken. The proposal is for two years of preclinical research and preparations, followed in the third year by a pilot clinical trial of ten patients with grade-IV astrocytoma brain tumors, for whom the prognosis with existing treatment modalities is less than a 5% three-year survival rate. Preclinical tasks would include modifying the MIT Nuclear Reactor medical facility to produce an epithermal as well as the existing and highly thermalized neutron treatment beam; characterizing the transport behavior of these beams in both physical and mathematical models of the human head, and developing a treatment planning scheme for NCT; further development of the neutron-induced alpha-autoradiography track-etch method for measuring macro- and micro-distributions of B-10 uptake in tissues and blood; investigations into the B-10 cellular uptake pattern of human tumors; and examination of the nature of endothelial cell vascular damage in B-10-containing animals undergoing irradiation with neutrons. With the successful completion of the above preclinical tasks we feel we will be in a position to embark in the third year on a pilot clinical evaluation

  9. Boron determination in biological samples - Intercomparison of three analytical methods to assist development of a treatment protocol for neoplastic diseases of the liver with Boron Neutron Capture Therapy

    OpenAIRE

    Schütz, Christian L.

    2012-01-01

    Die Bor-Neuroneneinfang-Therapie (engl.: Boron Neutron Capture Therapy, BNCT) ist eine indirekte Strahlentherapie, welche durch die gezielte Freisetzung von dicht ionisierender Strahlung Tumorzellen zerstört. Die freigesetzten Ionen sind Spaltfragmente einer Kernreaktion, bei welcher das Isotop 10B ein niederenergetisches (thermisches) Neutron einfängt. Das 10B wird durch ein spezielles Borpräparat in den Tumorzellen angereichert, welches selbst nicht radioaktiv ist. rnAn der Johannes Gutenbe...

  10. Electrostatic design and beam transport for a folded tandem electrostatic quadrupole accelerator facility for accelerator-based boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Thatar Vento, V., E-mail: Vladimir.ThatarVento@gmail.com [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [CONICET, Av. Rivadavia 1917 (1033), Ciudad Autonoma de Buenos Aires (Argentina); Bergueiro, J.; Cartelli, D. [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [CONICET, Av. Rivadavia 1917 (1033), Ciudad Autonoma de Buenos Aires (Argentina); Valda, A.A. [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [Escuela de Ciencia y Tecnologia, UNSAM, M. Irigoyen 3100 (1650), San Martin, Buenos Aires (Argentina); Kreiner, A.J. [Gerencia de Investigacion y Aplicaciones, CNEA, Av. Gral. Paz 1499 (1650), San Martin, Buenos Aires (Argentina)] [CONICET, Av. Rivadavia 1917 (1033), Ciudad Autonoma de Buenos Aires (Argentina)] [Escuela de Ciencia y Tecnologia, UNSAM, M. Irigoyen 3100 (1650), San Martin, Buenos Aires (Argentina)

    2011-12-15

    Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam.

  11. Preparation and characterization of Boron carbide nanoparticles for use as a novel agent in T cell-guided boron neutron capture therapy

    DEFF Research Database (Denmark)

    Mortensen, M. W.; Sørensen, P. G.; Björkdahl, O.;

    2006-01-01

    Boron carbide nanoparticles are proposed as a system for T cell-guided boron neutron capture therapy. Nanoparticles were produced by ball milling in various atmospheres of commercially available boron carbide. The physical and chemical properties of the particles were investigated using...

  12. Potential of para-boronophenylalaninol as a boron carrier in boron neutron capture therapy, referring to that of its enantiomers

    International Nuclear Information System (INIS)

    We evaluated the potential of a newly developed 10B-containing alpha-amino alcohol of para-boronophenylalanine-10B (BPA), para-boronophenylalaninol (BPAol), as a boron carrier in boron neutron capture therapy. C57BL mice bearing EL4 tumors and C3H/He mice bearing SCC VII tumors received 5-bromo-2'-deoxyuridine (BrdU) continuously via implanted mini-osmotic pumps to label all proliferating (P) cells. After oral administration of L-BPA or D-BPA, or intraperitoneal injection of L-BPAol or D-BPAol, the tumors were irradiated with reactor thermal neutron beams. For the combination with mild temperature hyperthermia (MTH) and/or tirapazamine (TPZ), the tumors were heated at 40 degrees centigrade for 30 minutes right before neutron exposure, and/or TPZ was intraperitoneally injected 30 minutes before irradiation. The tumors were then excised, minced and trypsinized. The tumor cell suspensions thus obtained were incubated with cytochalasin-B (a cytokinesis blocker), and the micronucleus (MN) frequency in cells without BrdU labeling ( = quiescent (Q) cells) was determined using immunofluorescence staining for BrdU. Meanwhile, 6 hours after irradiation, tumor cell suspensions obtained in the same manner were used for determining the apoptosis frequency in Q cells. The apoptosis and MN frequency in total (P + Q) tumor cells were determined from the tumors that were not pretreated with BrdU. Without TPZ or MTH, L- and D-BPAol increased both frequencies markedly, especially for total cells. Although not significantly, L-BPA and D-BPAol increased both frequencies slightly more remarkably than D-BPA and L-BPAol, respectively. On combined treatment with both MTH and TPZ, the sensitivity difference between total and Q cells was markedly reduced. MTH increased the 10B uptake of all 10B-carriers into both tumor cells to some degree. Both L- and D-BPAol have potential as 10B-carriers in neutron capture therapy, especially when combined with both MTH and TPZ

  13. Gadolinium uptake by brain cancer cells: Quantitative analysis with X-PEEM spectromicroscopy for cancer therapy

    Science.gov (United States)

    De Stasio, Gelsomina; Gilbert, B.; Perfetti, P.; Margaritondo, G.; Mercanti, D.; Ciotti, M. T.; Casalbore, P.; Larocca, L. M.; Rinelli, A.; Pallini, R.

    2000-05-01

    We present the first X-PEEM spectromicroscopy semi-quantitative data, acquired on Gd in glioblastoma cell cultures from human brain cancer. The cells were treated with a Gd compound for the optimization of GdNCT (Gadolinium Neutron Capture Therapy). We analyzed the kinetics of Gd uptake as a function of exposure time, and verified that a quantitative analytical technique gives the same results as our MEPHISTO X-PEEM, demonstrating the feasibility of semi-quantitative spectromicroscopy.

  14. Boron neutron capture therapy for undifferentiated thyroid carcinoma: preliminary results with the combined use of BPA and BOPP

    Energy Technology Data Exchange (ETDEWEB)

    Viaggi, M. E-mail: viaggi@cnea.gov.ar; Dagrosa, M.A.; Longhino, J.; Blaumann, H.; Calzetta, O.; Kahl, S.B.; Juvenal, G.J.; Pisarev, M.A

    2004-11-01

    We have shown the selective uptake of borophenylalanine (BPA) by undifferentiated human thyroid cancer (UTC) ARO cells both in vitro and in vivo. Moreover, a 50% histologic cure of mice bearing the tumor was observed when the complete boron neutron capture therapy was applied. More recently we have analyzed the biodistribution of BOPP (tetrakis-carborane carboxylate ester of 2,4-bis-({alpha},{beta}-dihydroxyethyl)-deutero-porphyrin IX) and showed that when BOPP was injected 5 days before BPA, and the animals were sacrificed 60 min after the i.p. injection of BPA, a significant increase in boron uptake by the tumor was found (38-45 ppm with both compounds vs. 20 ppm with BPA alone). Five days post the i.p BOPP injection and 1 h after BPA the ratios were: tumor/blood 3.75; tumor/distal skin 2. Other important ratios were tumor/thyroid 6.65 and tumor/lung 3.8. The present studies were performed in mice transplanted with ARO cells and injected with BOPP and BPA. Only in mice treated with the neutron beam and injected with the boronated compounds we observed a 100% control of tumor growth. Two groups of mice received different total absorbed doses: 3.00 and 6.01 Gy, but no further improvement in the outcome was found compared to the previous results using BPA alone (4.3 Gy)

  15. Stability of high-speed lithium sheet jets for the neutron source in Boron Neutron Capture Therapy (BNCT)

    International Nuclear Information System (INIS)

    The stability of high-speed liquid lithium sheet jets was analytically studied for the neutron source in Boron Neutron Capture Therapy (BNCT), which makes cancers and tumors curable with cell-level selections and hence high QOL. The object of our research is to realize the thin and high-speed plane sheet jets of liquid lithium in a high-vacuum as an accelerator target. Linear analysis approach is made to the stability on thin plane sheet jets of liquid lithium in a high-vacuum, and then our analytical results were compared with the previous experimental ones. We proved that the waves of surface tension on thin lithium sheet jets in a high-vacuum are of supercritical flows and neutral stable under about 17.4 m/s in flow velocity and that the fast non-dispersive anti-symmetric waves are more significant than the very slow dispersive symmetric waves. We also formulated the equation of shrinking angle in isosceles-triangularly or isosceles-trapezoidal shrinking sheet jets corresponding to the Mach angle of supersonic gas flows. This formula states universally the physical meaning of Weber number of sheet jets on the wave of surface tension in supercritical flows. We obtained satisfactory prospects (making choice of larger flow velocity U and larger thickness of sheet a) to materialize a liquid target of accelerator in BNCT. (author)

  16. In-phantom two-dimensional thermal neutron distribution for intraoperative boron neutron capture therapy of brain tumours

    International Nuclear Information System (INIS)

    The aim of this study was to determine the in-phantom thermal neutron distribution derived from neutron beams for intraoperative boron neutron capture therapy (IOBNCT). Gold activation wires arranged in a cylindrical water phantom with (void-in-phantom) or without (standard phantom) a cylinder styrene form placed inside were irradiated by using the epithermal beam (ENB) and the mixed thermal-epithermal beam (TNB-1) at the Japan Research Reactor No 4. With ENB, we observed a flattened distribution of thermal neutron flux and a significantly enhanced thermal flux delivery at a depth compared with the results of using TNB-1. The thermal neutron distribution derived from both the ENB and TNB-1 was significantly improved in the void-in-phantom, and a double high dose area was formed lateral to the void. The flattened distribution in the circumference of the void was observed with the combination of ENB and the void-in-phantom. The measurement data suggest that the ENB may provide a clinical advantage in the form of an enhanced and flattened dose delivery to the marginal tissue of a post-operative cavity in which a residual and/or microscopically infiltrating tumour often occurs. The combination of the epithermal neutron beam and IOBNCT will improve the clinical results of BNCT for brain tumours. (author)

  17. Boron neutron capture therapy design calculation of a 3H(p,n reaction based BSA for brain cancer setup

    Directory of Open Access Journals (Sweden)

    Bassem Elshahat

    2015-09-01

    Full Text Available Purpose: Boron neutron capture therapy (BNCT is a promising technique for the treatment of malignant disease targeting organs of the human body. Monte Carlo simulations were carried out to calculate optimum design parameters of an accelerator based beam shaping assembly (BSA for BNCT of brain cancer setup.Methods: Epithermal beam of neutrons were obtained through moderation of fast neutrons from 3H(p,n reaction in a high density polyethylene moderator and a graphite reflector. The dimensions of the moderator and the reflector were optimized through optimization of epithermal / fast neutron intensity ratio as a function of geometric parameters of the setup. Results: The results of our calculation showed the capability of our setup to treat the tumor within 4 cm of the head surface. The calculated peak therapeutic ratio for the setup was found to be 2.15. Conclusion: With further improvement in the polyethylene moderator design and brain phantom irradiation arrangement, the setup capabilities can be improved to reach further deep-seated tumor.

  18. Synthesis and evaluation of thymidine kinase 1-targeting carboranyl pyrimidine nucleoside analogs for boron neutron capture therapy of cancer.

    Science.gov (United States)

    Agarwal, Hitesh K; Khalil, Ahmed; Ishita, Keisuke; Yang, Weilian; Nakkula, Robin J; Wu, Lai-Chu; Ali, Tehane; Tiwari, Rohit; Byun, Youngjoo; Barth, Rolf F; Tjarks, Werner

    2015-07-15

    A library of sixteen 2nd generation amino- and amido-substituted carboranyl pyrimidine nucleoside analogs, designed as substrates and inhibitors of thymidine kinase 1 (TK1) for potential use in boron neutron capture therapy (BNCT) of cancer, was synthesized and evaluated in enzyme kinetic-, enzyme inhibition-, metabolomic-, and biodistribution studies. One of these 2nd generation carboranyl pyrimidine nucleoside analogs (YB18A [3]), having an amino group directly attached to a meta-carborane cage tethered via ethylene spacer to the 3-position of thymidine, was approximately 3-4 times superior as a substrate and inhibitor of hTK1 than N5-2OH (2), a 1st generation carboranyl pyrimidine nucleoside analog. Both 2 and 3 appeared to be 5'-monophosphorylated in TK1(+) RG2 cells, both in vitro and in vivo. Biodistribution studies in rats bearing intracerebral RG2 glioma resulted in selective tumor uptake of 3 with an intratumoral concentration that was approximately 4 times higher than that of 2. The obtained results significantly advance the understanding of the binding interactions between TK1 and carboranyl pyrimidine nucleoside analogs and will profoundly impact future design strategies for these agents. PMID:26087030

  19. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    CERN Document Server

    Kumada, H

    2002-01-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to ...

  20. Gamma/neutron dose evaluation using Fricke gel and alanine gel dosimeters to be applied in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Full text: Radiosurgery is a non-invasive surgery carried out by means of directed beams of ionizing radiation. This procedure was developed since there are many diseases for which conventional surgical treatment can not be applied, due to difficult or vital structures being damaged. Neutron radiation from nuclear reactors is used in a kind of radiosurgery called Boron Neutron Capture Therapy (BNCT) for the treatment of brain tumours which depends on the interaction of slow neutrons with 10B isotope injected in the tumour to produce alpha particles. Gel Dosimetry allows three-dimensional (3D) measurement of absorbed dose in tissueequivalent dosimeter phantoms. The measure technique is based on the transformation of ferrous ions (Fe2+) and ferric ions (Fe3+). The ferric ions concentration can be measured by spectrophotometry technique comparing the two wavelengths, 457 nm band that corresponds to ferrous ions concentration and 588 nm band that corresponds to ferric ions concentration. This work aims to study the gamma/neutron reactor dose relationship to be applied in BNCT using gel dosimeters. The Fricke Xylenol Gel (FXG) and Alanine Gel (AG) gel solutions produced at IPEN using gelatine 300 bloom were mixed with Na2B4O7 salt containing 19,9% of 10B isotope. This solutions were used to evaluate thermal and epithermal neutrons and gamma doses at an irradiation cell on BH3 of the IEA-R1 research reactor of IPEN

  1. Feasibility of boron neutron capture therapy (BNCT) for malignant pleural mesothelioma from a viewpoint of dose distribution analysis

    International Nuclear Information System (INIS)

    Purpose: To investigate the feasibility of boron neutron capture therapy (BNCT) for malignant pleural mesothelioma (MPM) from a viewpoint of dose distribution analysis using Simulation Environment for Radiotherapy Applications (SERA), a currently available BNCT treatment planning system. Methods and Materials: The BNCT treatment plans were constructed for 3 patients with MPM using the SERA system, with 2 opposed anterior-posterior beams. The 1B concentrations in the tumor and normal lung in this study were assumed to be 84 and 24 ppm, respectively, and were derived from data observed in clinical trials. The maximum, mean, and minimum doses to the tumors and the normal lung were assessed for each plan. The doses delivered to 5% and 95% of the tumor volume, D05 and D95, were adopted as the representative dose for the maximum and minimum dose, respectively. Results: When the D05 to the normal ipsilateral lung was 5 Gy-Eq, the D95 and mean doses delivered to the normal lung were 2.2-3.6 and 3.5-4.2 Gy-Eq, respectively. The mean doses delivered to the tumors were 22.4-27.2 Gy-Eq. The D05 and D95 doses to the tumors were 9.6-15.0 and 31.5-39.5 Gy-Eq, respectively. Conclusions: From a viewpoint of the dose-distribution analysis, BNCT has the possibility to be a promising treatment for MPM patients who are inoperable because of age and other medical illnesses

  2. The status of Tsukuba BNCT trial: BPA-based boron neutron capture therapy combined with X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, T., E-mail: tetsu_tsukuba@yahoo.co.jp [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)] [Department of Radiation Oncology, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan); Nakai, K. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan); Nariai, T. [Department of Neurosurgery, Tokyo Medical and Dental University, Yushima 1-5-45, Bunkyo-ku, Tokyo (Japan); Kumada, H.; Okumura, T.; Mizumoto, M.; Tsuboi, K. [Department of Radiation Oncology, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan); Zaboronok, A.; Ishikawa, E.; Aiyama, H.; Endo, K.; Takada, T.; Yoshida, F.; Shibata, Y.; Matsumura, A. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)

    2011-12-15

    The phase II trial has been prepared to assess the effectiveness of BPA (250 mg/kg)-based NCT combined with X-ray irradiation and temozolomide (75 mg/m{sup 2}) for the treatment of newly diagnosed GBM. BPA uptake is determined by {sup 18}F-BPA-PET and/or {sup 11}C-MET-PET, and a tumor with the lesion to normal ratio of 2 or more is indicated for BNCT. The maximum normal brain point dose prescribed was limited to 13.0 Gy or less. Primary end point is overall survival.

  3. Capture and Transport of Laser Accelerated Protons by Pulsed Magnetic Fields: Advancements Toward Laser-Based Proton Therapy

    Science.gov (United States)

    Burris-Mog, Trevor J.

    The interaction of intense laser light (I > 10 18 W/cm2) with a thin target foil leads to the Target Normal Sheath Acceleration mechanism (TNSA). TNSA is responsible for the generation of high current, ultra-low emittance proton beams, which may allow for the development of a compact and cost effective proton therapy system for the treatment of cancer. Before this application can be realized, control is needed over the large divergence and the 100% kinetic energy spread that are characteristic of TNSA proton beams. The work presented here demonstrates control over the divergence and energy spread using strong magnetic fields generated by a pulse power solenoid. The solenoidal field results in a parallel proton beam with a kinetic energy spread DeltaE/E = 10%. Assuming that next generation lasers will be able to operate at 10 Hz, the 10% spread in the kinetic energy along with the 23% capture efficiency of the solenoid yield enough protons per laser pulse to, for the first time, consider applications in Radiation Oncology. Current lasers can generate proton beams with kinetic energies up to 67.5 MeV, but for therapy applications, the proton kinetic energy must reach 250 MeV. Since the maximum kinetic energy Emax of the proton scales with laser light intensity as Emax ∝ I0.5, next generation lasers may very well accelerate 250 MeV protons. As the kinetic energy of the protons is increased, the magnetic field strength of the solenoid will need to increase. The scaling of the magnetic field B with the kinetic energy of the protons follows B ∝ E1/2. Therefor, the field strength of the solenoid presented in this work will need to be increased by a factor of 2.4 in order to accommodate 250 MeV protons. This scaling factor seems reasonable, even with present technology. This work not only demonstrates control over beam divergence and energy spread, it also allows for us to now perform feasibility studies to further research what a laser-based proton therapy system

  4. Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer.

    Science.gov (United States)

    Barth, Rolf F; Vicente, M Graca H; Harling, Otto K; Kiger, W S; Riley, Kent J; Binns, Peter J; Wagner, Franz M; Suzuki, Minoru; Aihara, Teruhito; Kato, Itsuro; Kawabata, Shinji

    2012-08-29

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Clinical interest in BNCT has focused primarily on the treatment of high grade gliomas, recurrent cancers of the head and neck region and either primary or metastatic melanoma. Neutron sources for BNCT currently have been limited to specially modified nuclear reactors, which are or until the recent Japanese natural disaster, were available in Japan, United States, Finland and several other European countries, Argentina and Taiwan. Accelerators producing epithermal neutron beams also could be used for BNCT and these are being developed in several countries. It is anticipated that the first Japanese accelerator will be available for therapeutic use in 2013. The major hurdle for the design and synthesis of boron delivery agents has been the requirement for selective tumor targeting to achieve boron concentrations in the range of 20 μg/g. This would be sufficient to deliver therapeutic doses of radiation with minimal normal tissue toxicity. Two boron drugs have been used clinically, a dihydroxyboryl derivative of phenylalanine, referred to as boronophenylalanine or "BPA", and sodium borocaptate or "BSH" (Na2B12H11SH). In this report we will provide an overview of other boron delivery agents that currently are under evaluation, neutron sources in use or under development for BNCT, clinical dosimetry, treatment planning, and finally a summary of previous and on-going clinical studies for high grade gliomas and recurrent tumors of the head and neck region. Promising results have been obtained with both groups of patients but these outcomes must be more rigorously evaluated in larger, possibly randomized clinical trials

  5. Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer

    Directory of Open Access Journals (Sweden)

    Barth Rolf F

    2012-08-01

    Full Text Available Abstract Boron neutron capture therapy (BNCT is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Clinical interest in BNCT has focused primarily on the treatment of high grade gliomas, recurrent cancers of the head and neck region and either primary or metastatic melanoma. Neutron sources for BNCT currently have been limited to specially modified nuclear reactors, which are or until the recent Japanese natural disaster, were available in Japan, United States, Finland and several other European countries, Argentina and Taiwan. Accelerators producing epithermal neutron beams also could be used for BNCT and these are being developed in several countries. It is anticipated that the first Japanese accelerator will be available for therapeutic use in 2013. The major hurdle for the design and synthesis of boron delivery agents has been the requirement for selective tumor targeting to achieve boron concentrations in the range of 20 μg/g. This would be sufficient to deliver therapeutic doses of radiation with minimal normal tissue toxicity. Two boron drugs have been used clinically, a dihydroxyboryl derivative of phenylalanine, referred to as boronophenylalanine or “BPA”, and sodium borocaptate or “BSH” (Na2B12H11SH. In this report we will provide an overview of other boron delivery agents that currently are under evaluation, neutron sources in use or under development for BNCT, clinical dosimetry, treatment planning, and finally a summary of previous and on-going clinical studies for high grade gliomas and recurrent tumors of the head and neck region. Promising results have been obtained with both groups of patients but these outcomes must be more rigorously evaluated in larger

  6. Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer

    International Nuclear Information System (INIS)

    Boron neutron capture therapy (BNCT) is a biochemically targeted radiotherapy based on the nuclear capture and fission reactions that occur when non-radioactive boron-10, which is a constituent of natural elemental boron, is irradiated with low energy thermal neutrons to yield high linear energy transfer alpha particles and recoiling lithium-7 nuclei. Clinical interest in BNCT has focused primarily on the treatment of high grade gliomas, recurrent cancers of the head and neck region and either primary or metastatic melanoma. Neutron sources for BNCT currently have been limited to specially modified nuclear reactors, which are or until the recent Japanese natural disaster, were available in Japan, the United States, Finland and several other European countries, Argentina and Taiwan. Accelerators producing epithermal neutron beams also could be used for BNCT and these are being developed in several countries. It is anticipated that the first Japanese accelerator will be available for therapeutic use in 2013. The major hurdle for the design and synthesis of boron delivery agents has been the requirement for selective tumor targeting to achieve boron concentrations in the range of 20 μg/g. This would be sufficient to deliver therapeutic doses of radiation with minimal normal tissue toxicity. Two boron drugs have been used clinically, a dihydroxyboryl derivative of phenylalanine, referred to as boronophenylalanine or “BPA”, and sodium borocaptate or “BSH” (Na2B12H11SH). In this report we will provide an overview of other boron delivery agents that currently are under evaluation, neutron sources in use or under development for BNCT, clinical dosimetry, treatment planning, and finally a summary of previous and on-going clinical studies for high grade gliomas and recurrent tumors of the head and neck region. Promising results have been obtained with both groups of patients but these outcomes must be more rigorously evaluated in larger, possibly randomized clinical

  7. Use of fluorine-18-BPA PET images and image registration to enhance radiation treatment planning for boron neutron capture therapy

    Science.gov (United States)

    Khan, Mohammad Khurram

    The Monte-Carlo based simulation environment for radiation therapy (SERA) software is used to simulate the dose administered to a patient undergoing boron neutron capture therapy (BNCT). Point sampling of tumor tissue results in an estimate of a uniform boron concentration scaling factor of 3.5. Under conventional treatment protocols, this factor is used to scale the boron component of the dose linearly and homogenously within the tumor and target volumes. The average dose to the tumor cells by such a method could be improved by better methods of quantifying the in-vivo 10B biodistribution. A better method includes radiolabeling para-Boronophenylalanine (p-BPA) with 18F and imaging the pharmaceutical using positron emission tomography (PET). This biodistribution of 18F-BPA can then be used to better predict the average dose delivered to the tumor regions. This work uses registered 18F-BPA PET images to incorporate the in-vivo boron biodistribution within current treatment planning. The registered 18F-BPA PET images are then coupled in a new computer software, PET2MRI.m, to linearly scale the boron component of the dose. A qualititative and quantitative assessment of the dose contours is presented using the two approaches. Tumor volume, tumor axial extent, and target locations are compared between using MRI or PET images to define the tumor volume. In addition, peak-to-normal brain value at tumor axial center is determined for pre and post surgery patients using 18F-BPA PET images. The differences noted between the registered GBM tumor volumes (range: 34.04--136.36%), tumor axial extent (range: 20--150%), and the beam target location (1.27--4.29 cm) are significantly different. The peak-to-normal brain values are also determined at the tumor axial center using the 18F-BPA PET images. The peak-to-normal brain values using the last frame of the pre-surgery study for the GBM patients ranged from 2.05--3.4. For post surgery time weighted PET data, the peak

  8. Boron neutron capture therapy applied to advanced breast cancers: Engineering simulation and feasibility study of the radiation treatment protocol

    Science.gov (United States)

    Sztejnberg Goncalves-Carralves, Manuel Leonardo

    This dissertation describes a novel Boron Neutron Capture Therapy (BNCT) application for the treatment of human epidermal growth factor receptor type 2 positive (HER2+) breast cancers. The original contribution of the dissertation is the development of the engineering simulation and the feasibility study of the radiation treatment protocol for this novel combination of BNCT and HER2+ breast cancer treatment. This new concept of BNCT, representing a radiation binary targeted treatment, consists of the combination of two approaches never used in a synergism before. This combination may offer realistic hope for relapsed and/or metastasized breast cancers. This treatment assumes that the boronated anti-HER2 monoclonal antibodies (MABs) are administrated to the patient and accumulate preferentially in the tumor. Then the tumor is destroyed when is exposed to neutron irradiation. Since the use of anti-HER2 MABs yields good and promising results, the proposed concept is expected to amplify the known effect and be considered as a possible additional treatment approach to the most severe breast cancers for patients with metastasized cancer for which the current protocol is not successful and for patients refusing to have the standard treatment protocol. This dissertation makes an original contribution with an integral numerical approach and proves feasible the combination of the aforementioned therapy and disease. With these goals, the dissertation describes the theoretical analysis of the proposed concept providing an integral engineering simulation study of the treatment protocol. An extensive analysis of the potential limitations, capabilities and optimization factors are well studied using simplified models, models based on real CT patients' images, cellular models, and Monte Carlo (MCNP5/X) transport codes. One of the outcomes of the integral dosimetry assessment originally developed for the proposed treatment of advanced breast cancers is the implementation of BNCT

  9. NIFTI and DISCOS: New concepts for a compact accelerator neutron source for boron neutron capture therapy applications

    International Nuclear Information System (INIS)

    Two new concepts, NIFTI and DISCOS, are described. These concepts enable the efficient production of epithermal neutrons for BNCT (Boron Neutron Capture Therapy) medical treatment, utilizing a low current, low energy proton beam impacting on a lithium target. The NIFTI concept uses fluoride compounds, such as lead or beryllium fluoride, to efficiently degrade high energy neutrons from the lithium target to the lower energies required for BNCT. The fluoride compounds are in turn encased in an iron layer that strongly impedes the transmission of neutrons with energies above 24 KeV. Lower energy neutrons readily pass through this iron filter, which has a deep window in its scattering cross section at 24 KeV. The DISCOS concept uses a rapidly rotating, high g disc to create a series of thin (∼ 1 micron thickness) liquid lithium targets in the form of continuous films or sheets of discrete droplets--through which the proton beam passes. The average energy lost by a proton as it passes through a single target is small, approximately 10 KeV. Between the targets, the proton beam is re-accelerated by an applied DC electric field. The DISCOS approach enables the accelerator--target facility to operate with a beam energy only slightly above the threshold value for neutron production--resulting in an output beam of low-energy epithermal neutrons--while achieving a high yield of neutrons per milliamp of proton beam current. Parametric trade studies of the NIFTI and DISCOS concepts are described. These include analyses of a broad range of NIFTI designs using the Monte carlo MCNP neutronics code, as well as mechanical and thermal-hydraulic analyses of various DISCOS designs

  10. Characteristics comparison between a cyclotron-based neutron source and KUR-HWNIF for boron neutron capture therapy

    Science.gov (United States)

    Tanaka, H.; Sakurai, Y.; Suzuki, M.; Masunaga, S.; Kinashi, Y.; Kashino, G.; Liu, Y.; Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Maruhashi, A.; Ono, K.

    2009-06-01

    At Kyoto University Research Reactor Institute (KURRI), 275 clinical trials of boron neutron capture therapy (BNCT) have been performed as of March 2006, and the effectiveness of BNCT has been revealed. In order to further develop BNCT, it is desirable to supply accelerator-based epithermal-neutron sources that can be installed near the hospital. We proposed the method of filtering and moderating fast neutrons, which are emitted from the reaction between a beryllium target and 30-MeV protons accelerated by a cyclotron accelerator, using an optimum moderator system composed of iron, lead, aluminum and calcium fluoride. At present, an epithermal-neutron source is under construction from June 2008. This system consists of a cyclotron accelerator, beam transport system, neutron-yielding target, filter, moderator and irradiation bed. In this article, an overview of this system and the properties of the treatment neutron beam optimized by the MCNPX Monte Carlo neutron transport code are presented. The distribution of biological effect weighted dose in a head phantom compared with that of Kyoto University Research Reactor (KUR) is shown. It is confirmed that for the accelerator, the biological effect weighted dose for a deeply situated tumor in the phantom is 18% larger than that for KUR, when the limit dose of the normal brain is 10 Gy-eq. The therapeutic time of the cyclotron-based neutron sources are nearly one-quarter of that of KUR. The cyclotron-based epithermal-neutron source is a promising alternative to reactor-based neutron sources for treatments by BNCT.

  11. Tumor cell killing effect of boronated dipeptide. Boromethylglycylphenylalanine on boron neutron capture therapy for malignant brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Takagaki, Masao; Ono, Koji; Masunaga, Shinichiro; Kinashi, Yuko; Kobayashi, Toru [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Oda, Yoshifumi; Kikuchi, Haruhiko; Spielvogel, B.F.

    1994-03-01

    The killing effect of Boron Neutron Capture Therapy; BNCT, is dependant on the boron concentration ratio of tumor to normal brain (T/N ratio), and also that of tumor to blood (T/B ratio). The clinical boron carrier of boro-captate (BSH) showed the large T/N ratio of ca. 8, however the T/B ratio was around 1, which indicated nonselective accumulation into tumor. Indeed high boron concentration of blood restrict the neutron irradiation dose in order to circumvent the normal endothelial damage, especially in the case of deeply seated tumor. Phenylalanine analogue of para borono-phenylalanine (BPA) is an effective boron carrier on BNCT for malignant melanoma. For the BNCT on brain tumors, however, BPA concentration in normal brain was reported to be intolerably high. In order to improve the T/N ratio of BPA in brain, therefore, a dipeptide of boromethylglycylphenylalanine (BMGP) was synthesized deriving from trimethylglycine conjugated with BPA. It is expected to be selectively accumulated into tumor with little uptake into normal brain. Because a dipeptide might not pass through the normal blood brain barrier (BBB). Its killing effect on cultured glioma cell, T98G, and its distribution in rat brain bearing 9L glioma have been investigated in this paper. The BNCT effect of BMGP on cultured cells was nearly triple in comparison with DL-BPA. The neutron dose yielding 1% survival ratio were 7x10{sup 12}nvt for BMGP and 2x10{sup 13}nvt for BPA respectively on BNCT after boron loading for 16 hrs in the same B-10 concentration of 20ppm. Quantitative study of boron concentration via the {alpha}-auto radiography and the prompt gamma ray assay on 9L brain tumor rats revealed that T/N ratio and T/B ratio are 12.0 and 3.0 respectively. Those values are excellent for BNCT use. (author).

  12. Role of p53 mutation in the effect of boron neutron capture therapy on oral squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Ohnishi Ken

    2009-12-01

    Full Text Available Abstract Background Boron neutron capture therapy (BNCT is a selective radiotherapy, being effective for the treatment of even advanced malignancies in head and neck regions as well as brain tumors and skin melanomas. To clarify the role of p53 gene, the effect of BNCT on oral squamous cell carcinoma (SCC cells showing either wild- (SAS/neo or mutant-type (SAS/mp53 p53 was examined. Methods Cells were exposed to neutron beams in the presence of boronophenylalanine (BPA at Kyoto University Research Reactor. Treated cells were monitored for modulations in colony formation, proliferation, cell cycle, and expression of cell cycle-associated proteins. Results When SAS/neo and SAS/mp53 cells were subjected to BNCT, more suppressive effects on colony formation and cell viability were observed in SAS/neo compared with SAS/mp53 cells. Cell cycle arrest at the G1 checkpoint was observed in SAS/neo, but not in SAS/mp53. Apoptotic cells increased from 6 h after BNCT in SAS/neo and 48 h in SAS/mp53 cells. The expression of p21 was induced in SAS/neo only, but G2 arrest-associated proteins including Wee1, cdc2, and cyclin B1 were altered in both cell lines. Conclusion These results indicate that oral SCC cells with mutant-type are more resistant to BNCT than those with wild-type p53, and that the lack of G1 arrest and related apoptosis may contribute to the resistance. At a physical dose affecting the cell cycle, BNCT inhibits oral SCC cells in p53-dependent and -independent manners.

  13. Demonstration of three-dimensional deterministic radiation transport theory dose distribution analysis for boron neutron capture therapy

    International Nuclear Information System (INIS)

    The Monte Carlo stochastic simulation technique has traditionally been the only well-recognized method for computing three-dimensional radiation dose distributions in connection with boron neutron capture therapy (BNCT) research. A deterministic approach to this problem would offer some advantages over the Monte Carlo method. This paper describes an application of a deterministic method to analytically simulate BNCT treatment of a canine head phantom using the epithermal neutron beam at the Brookhaven medical research reactor (BMRR). Calculations were performed with the TORT code from Oak Ridge National Laboratory (ORNL), an implementation of the discrete ordinates, or Sn method. Calculations were from first principles and used no empirical correction factors. The phantom surface was modeled by flat facets of approximately 1 cm2. The phantom interior was homogeneous. Energy-dependent neutron and photon scalar fluxes were calculated on a 32x16x22 mesh structure with 96 discrete directions in angular phase space. The calculation took 670 min on an Apollo DN10000 workstation. The results were subsequently integrated over energy to obtain full three-dimensional dose distributions. Isodose contours and depth-dose curves were plotted for several separate dose components of interest. Phantom measurements were made by measuring neutron activation (and therefore neutron flux) as a function of depth in copper--gold alloy wires that were inserted through catheters placed in holes drilled in the phantom. Measurements agreed with calculations to within about 15%. The calculations took about an order of magnitude longer than comparable Monte Carlo calculations but provided various conveniences, as well as a useful check

  14. Proton magnetic resonance spectroscopy of a boron neutron capture therapy 10B-carrier, L-p-boronophenylalanine-fructose complex

    Energy Technology Data Exchange (ETDEWEB)

    Timonen, M.

    2010-07-01

    Boron neutron capture therapy (BNCT) is a radiotherapy that has mainly been used to treat malignant brain tumours, melanomas, and head and neck cancer. In BNCT, the patient receives an intravenous infusion of a 10B-carrier, which accumulates in the tumour area. The tumour is irradiated with epithermal or thermal neutrons, which result in a boron neutron capture reaction that generates heavy particles to damage tumour cells. In Finland, boronophenylalanine fructose (BPA-F) is used as the 10B-carrier. Currently, the drifting of boron from blood to tumour as well as the spatial and temporal accumulation of boron in the brain, are not precisely known. Proton magnetic resonance spectroscopy (1H MRS) could be used for selective BPA-F detection and quantification as aromatic protons of BPA resonate in the spectrum region, which is clear of brain metabolite signals. This study, which included both phantom and in vivo studies, examined the validity of 1H MRS as a tool for BPA detection. In the phantom study, BPA quantification was studied at 1.5 and 3.0 T with single voxel 1H MRS, and at 1.5 T with magnetic resonance imaging (MRSI). The detection limit of BPA was determined in phantom conditions at 1.5 T and 3.0 T using single voxel 1H MRS, and at 1.5 T using MRSI. In phantom conditions, BPA quantification accuracy of +- 5% and +- 15% were achieved with single voxel MRS using external or internal (internal water signal) concentration references, respectively. For MRSI, a quantification accuracy of <5% was obtained using an internal concentration reference (creatine). The detection limits of BPA in phantom conditions for the PRESS sequence were 0.7 (3.0 T) and 1.4 mM (1.5 T) mM with 20 x 20 single voxel MRS, and 1.0 mM with acquisition-weighted MRSI, respectively. In the in vivo study, an MRSI or single voxel MRS or both was performed for ten patients (patients 1-10) on the day of BNCT. Three patients had glioblastoma multiforme (GBM), and five patients had a recurrent or

  15. Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Yoshinori, E-mail: yosakura@rri.kyoto-u.ac.jp; Tanaka, Hiroki; Kondo, Natsuko; Kinashi, Yuko; Suzuki, Minoru; Masunaga, Shinichiro; Ono, Koji; Maruhashi, Akira [Kyoto University Research Reactor Institute, Asashironishi 2-1010, Kumatori-cho, Sennan-gun, Osaka 590-0494 (Japan)

    2015-11-15

    Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % {sup 6}LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % {sup 6}LiOH solution based on the simulation results. Experimental characterization of the

  16. Preparation and characterization of Boron carbide nanoparticles for use as a novel agent in T cell-guided boron neutron capture therapy.

    Science.gov (United States)

    Mortensen, M W; Sørensen, P G; Björkdahl, O; Jensen, M R; Gundersen, H J G; Bjørnholm, T

    2006-03-01

    Boron carbide nanoparticles are proposed as a system for T cell-guided boron neutron capture therapy. Nanoparticles were produced by ball milling in various atmospheres of commercially available boron carbide. The physical and chemical properties of the particles were investigated using transmission electron microscopy, photon correlation spectroscopy, X-ray photoelectron spectroscopy, X-ray diffraction, vibrational spectroscopy, gel electrophoresis and chemical assays and reveal profound changes in surface chemistry and structural characteristics. In vitro thermal neutron irradiation of B16 melanoma cells incubated with sub-100 nm nanoparticles (381.5 microg/g (10)B) induces complete cell death. The nanoparticles alone induce no toxicity.

  17. Development of high intensity ion sources for a Tandem-Electrostatic-Quadrupole facility for Accelerator-Based Boron Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bergueiro, J. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica (Argentina)] [CONICET, Buenos Aires (Argentina); Igarzabal, M.; Suarez Sandin, J.C. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica (Argentina); Somacal, H.R. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica (Argentina)] [Escuela de Ciencia y Tecnologia, Universidad Nacional de San Martin (Argentina); Thatar Vento, V. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica (Argentina)] [CONICET, Buenos Aires (Argentina); Huck, H.; Valda, A.A. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica (Argentina)] [Escuela de Ciencia y Tecnologia, Universidad Nacional de San Martin (Argentina); Repetto, M. [Gerencia de Investigacion y Aplicaciones, Comision Nacional de Energia Atomica (Argentina)

    2011-12-15

    Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes.

  18. Boron neutron capture therapy for clear cell sarcoma (CCS): Biodistribution study of p-borono-L-phenylalanine in CCS-bearing animal models

    Energy Technology Data Exchange (ETDEWEB)

    Andoh, T. [Laboratory of Pharmaceutical Technology, Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, Kobe 650-8586 (Japan); Fujimoto, T. [Department of Orthopaedic Surgery, Hyogo Cancer Center, Akashi 673-0021 (Japan); Sudo, T. [Section of Translational Research, Hyogo Cancer Center, Akashi 673-0021 (Japan); Fujita, I.; Imabori, M. [Department of Orthopaedic Surgery, Hyogo Cancer Center, Akashi 673-0021 (Japan); Moritake, H. [Department of Pediatrics, Miyazaki University, Kiyotake 889-1692 (Japan); Sugimoto, T. [Department of Pediatrics, Saiseikai Shigaken Hospital, Ritto 520-3046 (Japan); Sakuma, Y. [Department of Pathology, Hyogo Cancer Center, Akashi 673-0021 (Japan); Takeuchi, T. [Department of Pathology, Kochi University, Nangoku 783-8505 (Japan); Kawabata, S. [Department of Neurosurgery, Osaka Medical College, Osaka 569-8686 (Japan); Kirihata, M. [Graduate School of Life and Environmental Sciences, Osaka Prefecture University, Sakai 599-8531 (Japan); Akisue, T. [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Yayama, K. [Laboratory of Cardiovascular Pharmacology, Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, Kobe 650-8586 (Japan); Kurosaka, M. [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017 (Japan); Miyatake, S. [Department of Neurosurgery, Osaka Medical College, Osaka 569-8686 (Japan); Fukumori, Y. [Laboratory of Pharmaceutical Technology, Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, Kobe 650-8586 (Japan); Ichikawa, H., E-mail: ichikawa@pharm.kobegakuin.ac.jp [Laboratory of Pharmaceutical Technology, Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, Kobe 650-8586 (Japan)

    2011-12-15

    Clear cell sarcoma (CCS) is a rare melanocytic malignant tumor with a poor prognosis. Our previous study demonstrated that in vitro cultured CCS cells have the ability to highly uptake L-BPA and thus boron neutron capture therapy could be a new option for CCS treatment. This paper proved that a remarkably high accumulation of {sup 10}B (45-74 ppm) in tumor was obtained even in a CCS-bearing animal with a well-controlled biodistribution followed by intravenous administration of L-BPA-fructose complex (500 mg BPA/kg).

  19. Capturing Thoughts, Capturing Minds?

    DEFF Research Database (Denmark)

    Nielsen, Janni

    2004-01-01

    Think Aloud is cost effective, promises access to the user's mind and is the applied usability technique. But 'keep talking' is difficult, besides, the multimodal interface is visual not verbal. Eye-tracking seems to get around the verbalisation problem. It captures the visual focus of attention...

  20. Study of the interaction of boron-containing amino acids for the neutron capture therapy with biologically interesting compounds by using 'three-spot zone electrophoresis'

    International Nuclear Information System (INIS)

    As the boron carriers for boron neutron capture therapy, p-borono phenylalanine (BPA) is the boron compound which has been clinically used together with sodium borocaptate. It was found by the electrophoresis behavior that the BPA interacted with organic carboxylic acids in its dissolved state. In this paper, the electrophoresis behavior of general amino acids as seen in three-spot zone electrophoresis and the peculiar interaction of the amino acids having dihydroxyboryl radical are described. Zone electrophoresis has been developed as separation means, and three-spot process excludes the errors due to accidental factors as far as possible. The behaviors of zone electrophoresis of ordinary neutral amino acids, orthoboric acid and p-BPA are reported. For utilizing the features of boron neutron capture therapy, it is necessary to develop the carrier which is singularly taken into cancer cells. There is not a good method for discriminating normal cells and cancer cells. As for the administration of BPA to patients, its solubility is insufficient, therefore, its fructose complex has been used. The research on the biochemical peculiarity of boron is important. (K.I.)

  1. Boron neutron capture therapy of glioblastoma multiforme using the p- boronophenylalanine-fructose complex and epithermal neutrons

    International Nuclear Information System (INIS)

    The amino acid analogue p-boronophenylalanine (BPA) is under investigation as a neutron capture agent for BNCT of glioblastoma multiforme. A series of patients undergoing surgical removal of tumor received BPA orally as the free amino acid. Favorable tumor/blood boron concentration ratios were obtained but the absolute amount of boron in the tumor would have been insufficient for BNCT. BPA can be solubilized at neutral pH by complexation with fructose (BPA-F). Studies with rats suggest that intraperitoneal injection of BPA-F complex produces a much higher tumor boron concentration to rat intracerebral 9L gliosarcoma that were possible with oral BPA. Higher boron concentrations have allowed higher tumor radiation doses to be delivered while maintaining the dose to the normal brain vascular endothelium below the threshold of tolerance. The experience to date of the administration of BPA-F to one patient is provided in this report

  2. Conceptual design project: Accelerator complex for nuclear physics studies and boron neutron capture therapy application at the Yerevan Physics Institute (YerPhI) Yerevan, Armenia

    Energy Technology Data Exchange (ETDEWEB)

    Avagyan, R.H.; Kerobyan, I.A.

    2015-07-15

    The final goal of the proposed project is the creation of a Complex of Accelerator Facilities at the Yerevan Physics Institute (CAF YerPhI) for nuclear physics basic researches, as well as for applied programs including boron neutron capture therapy (BNCT). The CAF will include the following facilities: Cyclotron C70, heavy material (uranium) target/ion source, mass-separator, LINAC1 (0.15–1.5 MeV/u) and LINAC2 (1.5–10 MeV/u). The delivered by C70 proton beams with energy 70 MeV will be used for investigations in the field of basic nuclear physics and with energy 30 MeV for use in applications.

  3. Biodistribution of nanoparticles of hydrophobic gadopentetic-acid derivative prepared with a planetary ball mill for neutron-capture therapy of cancer

    International Nuclear Information System (INIS)

    Nanoparticles of hydrophobic gadopentetic-acid derivatives (Gd-nanoGR) were prepared with a wet ball-milling process for gadolinium neutron-capture therapy. Ball-milling of solid mass of gadopentetic acid distearylamide with soybean lecithin as a dispersant in the presence of water and subsequent sonication at 70degC resulted in the Gd-nanoGR with the particle size of 63 nm. Biodistribution study using melanoma-bearing hamsters demonstrated that the i.v. injection of the Gd-nanoGR made a higher gadolinium accumulation in tumor (109 μg Gd/g wet tumor at 6h after administration), when compared with the gadolinium-loaded micellar-like nanoparticles previously reported. (author)

  4. Controllability of depth dose distribution for neutron capture therapy at the Heavy Water Neutron Irradiation Facility of Kyoto University Research Reactor.

    Science.gov (United States)

    Sakurai, Yoshinori; Kobayashi, Tooru

    2002-10-01

    The updating construction of the Heavy Water Neutron Irradiation Facility of the Kyoto University Research Reactor has been performed from November 1995 to March 1996 mainly for the improvement in neutron capture therapy. On the performance, the neutron irradiation modes with the variable energy spectra from almost pure thermal to epi-thermal neutrons became available by the control of the heavy-water thickness in the spectrum shifter and by the open-and-close of the cadmium and boral thermal neutron filters. The depth distributions of thermal, epi-thermal and fast neutron fluxes were measured by activation method using gold and indium, and the depth distributions of gamma-ray absorbed dose rate were measured using thermo-luminescent dosimeter of beryllium oxide for the several irradiation modes. From these measured data, the controllability of the depth dose distribution using the spectrum shifter and the thermal neutron filters was confirmed.

  5. Pharmaco-thermodynamics of deuterium-induced oedema in living rat brain via 1H2O MRI: implications for boron neutron capture therapy of malignant brain tumours

    International Nuclear Information System (INIS)

    In addition to its common usage as a tracer in metabolic and physiological studies, deuterium possesses anti-tumoural activity and confers protection against γ-irradiation. A more recent interest in deuterium emanates from the search for alternatives capable of improving neutron penetrance whilst reducing healthy tissue radiation dose deposition in boron neutron capture therapy of malignant brain tumours. Despite this potential clinical application, deuterium induces brain oedema, which is detrimental to neutron capture therapy. In this study, five adult male rats were titrated with deuterated drinking water while brain oedema was monitored via water proton magnetic resonance imaging. This report concludes that deuterium, as well as deuterium-induced brain oedema, possesses a uniform brain bio-distribution. At a steady-state blood fluid deuteration value of 16%, when the deuterium isotope fraction in drinking water was 25%, a mean oedematous volume change of 9 ± 2% (p-value <0.001) was observed in the rat brain-this may account for neurological and behavioural abnormalities found in mammals drinking highly deuterated water. In addition to characterizing the pharmaco-thermodynamics of deuterium-induced oedema, this report also estimates the impact of oedema on thermal neutron enhancement and effective dose reduction factors using simple linear transport calculations. While body fluid deuteration enhances thermal neutron flux penetrance and reduces dose deposition, oedema has the opposite effect because it increases the volume of interest, e.g., the brain volume. Thermal neutron enhancement and effective dose reduction factors could be reduced by as much as ∼10% in the presence of a 9% water volume increase (oedema)

  6. Folate receptor-mediated boron-10 containing carbon nanoparticles as potential delivery vehicles for boron neutron capture therapy of nonfunctional pituitary adenomas.

    Science.gov (United States)

    Dai, Congxin; Cai, Feng; Hwang, Kuo Chu; Zhou, Yongmao; Zhang, Zizhu; Liu, Xiaohai; Ma, Sihai; Yang, Yakun; Yao, Yong; Feng, Ming; Bao, Xinjie; Li, Guilin; Wei, Junji; Jiao, Yonghui; Wei, Zhenqing; Ma, Wenbin; Wang, Renzhi

    2013-02-01

    Invasive nonfunctional pituitary adenomas (NFPAs) are difficult to completely resect and often develop tumor recurrence after initial surgery. Currently, no medications are clinically effective in the control of NFPA. Although radiation therapy and radiosurgery are useful to prevent tumor regrowth, they are frequently withheld because of severe complications. Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively and maximally damages tumor cells without harming the surrounding normal tissue. Folate receptor (FR)-targeted boron-10 containing carbon nanoparticles is a novel boron delivery agent that can be selectively taken up by FR-expressing cells via FR-mediated endocytosis. In this study, FR-targeted boron-10 containing carbon nanoparticles were selectively taken up by NFPAs cells expressing FR but not other types of non-FR expressing pituitary adenomas. After incubation with boron-10 containing carbon nanoparticles and following irradiation with thermal neutrons, the cell viability of NFPAs was significantly decreased, while apoptotic cells were simultaneously increased. However, cells administered the same dose of FR-targeted boron-10 containing carbon nanoparticles without neutron irradiation or received the same neutron irradiation alone did not show significant decrease in cell viability or increase in apoptotic cells. The expression of Bcl-2 was down-regulated and the expression of Bax was up-regulated in NFPAs after treatment with FR-mediated BNCT. In conclusion, FR-targeted boron-10 containing carbon nanoparticles may be an ideal delivery system of boron to NFPAs cells for BNCT. Furthermore, our study also provides a novel insight into therapeutic strategies for invasive NFPA refractory to conventional therapy, while exploring these new applications of BNCT for tumors, especially benign tumors.

  7. Prevalence of anemia amongst overweight and obese children in NCT of Delhi

    Directory of Open Access Journals (Sweden)

    Umesh Kapil

    2014-09-01

    Full Text Available Introduction: Anemia amongst children has been associated with impaired cognitive functions, developmental delays, behavioral and learning disturbances. Young children from high-income groups could be also being affected from anemia. Objective: To assess the prevalence of anemia amongst overweight and obese children in the age group of 5-18 years residing in National Capital Territory (NCT of Delhi. Material and Methods: Total of 413 children was included in the present study. The hemoglobin (Hb estimation was done by cyanmethemoglobin method. Results: In the age group of 5-11 years, the prevalence of anemia amongst overweight and obese children was found to be 38.4% and 29.2%. And in the age group of 12-18 years, the prevalence of anemia amongst overweight and obese children was found to be 33.3% and 21.7%; respectively. Conclusion: The findings of the present study revealed that there is a high prevalence of anemia amongst overweight and obese children in the age group of 5-18 years in NCT, Delhi.

  8. Identification of early and distinct glioblastoma response patterns treated by boron neutron capture therapy not predicted by standard radiographic assessment using functional diffusion map

    International Nuclear Information System (INIS)

    Radiologic response of brain tumors is traditionally assessed according to the Macdonald criteria 10 weeks from the start of therapy. Because glioblastoma (GB) responds in days rather than weeks after boron neutron capture therapy (BNCT) that is a form of tumor-selective particle radiation, it is inconvenient to use the Macdonald criteria to assess the therapeutic efficacy of BNCT by gadolinium-magnetic resonance imaging (Gd-MRI). Our study assessed the utility of functional diffusion map (fDM) for evaluating response patterns in GB treated by BNCT. The fDM is an image assessment using time-dependent changes of apparent diffusion coefficient (ADC) in tumors on a voxel-by-voxel approach. Other than time-dependent changes of ADC, fDM can automatically assess minimum/maximum ADC, Response Evaluation Criteria In Solid Tumors (RECIST), and the volume of enhanced lesions on Gd-MRI over time. We assessed 17 GB patients treated by BNCT using fDM. Additionally, in order to verify our results, we performed a histopathological examination using F98 rat glioma models. Only the volume of tumor with decreased ADC by fDM at 2 days after BNCT was a good predictor for GB patients treated by BNCT (P value = 0.022 by log-rank test and 0.033 by wilcoxon test). In a histopathological examination, brain sections of F98 rat glioma models treated by BNCT showed cell swelling of both the nuclei and the cytoplasm compared with untreated rat glioma models. The fDM could identify response patterns in BNCT-treated GB earlier than a standard radiographic assessment. Early detection of treatment failure can allow a change or supplementation before tumor progression and might lead to an improvement of GB patients’ prognosis

  9. Radiation dosimetry for NCT facilities at the Brookhaven Medical Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Holden, N.E.; Hu, J.P.; Greenberg, D.D.; Reciniello, R.N.

    1998-12-31

    Brookhaven Medical Research Reactor (BMRR) is a 3 mega-watt (MW) heterogeneous, tank-type, light water cooled and moderated, graphite reflected reactor, which was designed for medical and biological studies and became operational in 1959. Over time, the BMRR was modified to provide thermal and epithermal neutron beams suitable for research studies. NCT studies have been performed at both the epithermal neutron irradiation facility (ENIF) on the east side of the BMRR reactor core and the thermal neutron irradiation facility (TNIF) on the west side of the core. Neutron and gamma-ray dosimetry performed from 1994 to the present in both facilities are described and the results are presented and discussed.

  10. Synchrotron radiation based microtomography (SR{mu}CT) and neutron tomography (NCT) for materials science

    Energy Technology Data Exchange (ETDEWEB)

    Beckmann, Felix; Herzen, Julia; Donath, Tilman; Haibel, Astrid; Dose, Thomas; Vollbrandt, Juergen; Schmitz, Heinz-Werner; Pranzas, Philipp Klaus; Schreyer, Andreas [GKSS-Research Centre, Geesthacht (Germany)

    2008-07-01

    The GKSS-Research Centre Geesthacht, Germany, is operating the user experiment for microtomography using synchrotron radiation at the storage ring DORIS 3 at DESY Hamburg. In the recents years the beamline W2 was rebuilt. The outstanding feature of this synchrotron radiation beamline HARWI II is the use of high energy X-rays from 20 to 250 keV for materials science experiments. The features for microtomography at HARWI II and new enhancements and applications using lower photon energies at the wiggler beamline BW2 are presented. Furthermore at the research reactor FRG-1 the neutron radiography facility GENRA 3 was extended by a setup for neutron tomography. Results performing SR{mu}CT at HARWI 2 and NCT at GENRA 3 are presented. The combination of neutron and synchrotron radiation techniques will give new insight into the three-dimensional behavior of samples in materials science.

  11. Use of boron cluster-containing redox nanoparticles with ROS scavenging ability in boron neutron capture therapy to achieve high therapeutic efficiency and low adverse effects.

    Science.gov (United States)

    Gao, Zhenyu; Horiguchi, Yukichi; Nakai, Kei; Matsumura, Akira; Suzuki, Minoru; Ono, Koji; Nagasaki, Yukio

    2016-10-01

    A boron delivery system with high therapeutic efficiency and low adverse effects is crucial for a successful boron neutron capture therapy (BNCT). In this study, we developed boron cluster-containing redox nanoparticles (BNPs) via polyion complex (PIC) formation, using a newly synthesized poly(ethylene glycol)-polyanion (PEG-polyanion, possessing a (10)B-enriched boron cluster as a side chain of one of its segments) and PEG-polycation (possessing a reactive oxygen species (ROS) scavenger as a side chain of one of its segments). The BNPs exhibited high colloidal stability, selective uptake in tumor cells, specific accumulation, and long retention in tumor tissue and ROS scavenging ability. After thermal neutron irradiation, significant suppression of tumor growth was observed in the BNP-treated group, with only 5-ppm (10)B in tumor tissues, whereas at least 20-ppm (10)B is generally required for low molecular weight (LMW) (10)B agents. In addition, increased leukocyte levels were observed in the LMW (10)B agent-treated group after thermal neutron irradiation, and not in BNP-treated group, which might be attributed to its ROS scavenging ability. No visual metastasis of tumor cells to other organs was observed 1 month after irradiation in the BNP-treated group. These results suggest that BNPs are promising for enhancing the BNCT performance. PMID:27467416

  12. Neutron capture therapy clinical development in the world%中子俘获疗法临床应用国际进展

    Institute of Scientific and Technical Information of China (English)

    张紫竹; 金从军; 刘凯; 张国珍; 杨立军

    2012-01-01

    硼中子俘获疗法(BNCT)目前在国际上已经临床应用于千余例患者,并取得了较好的治疗效果.主要对BNCT的原理、发展历史及国际BNCT临床进展情况作了主要介绍.对脑胶质瘤、恶性黑色素瘤、复发性头颈部肿瘤及转移性肝癌BNCT临床治疗情况及治疗效果作了较详细的讨论.%Boron neutron capture therapy (BNCT) method was applied to about one thousand clinical patients and achieved good results internationally. In this paper, the principle of BNCT, the development history and international BNCT clinical progress were mainly introduced. The BNCT clinical treatment situation and evaluation in glioblastoma (GBM) , malignant melanoma, recurrent head and neck cancer and metastatic liver cancer were discussed in detail.

  13. Design calculations of an epithermal neutron beam and development of a treatment planning system for the renovation of thor for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Tsing Hua University was recently granted by National Science Council a five-year project to renovate its Open-Pool reactor (THOR) for boron neutron capture therapy. With this support, the whole graphite blocks in the original thermal column region can be removed for redesigning and constructing a better epithermal neutron beam. THOR is a 1 MW research reactor. The cross section area of the core facing the thermal column is 60 cm x 50 cm. By using 60 cm FLUENTAL plus 10 cm Pb, with cross section area of 70 cm x 60 cm and surrounded by 6 cm thick PbF2 reflector, the epithermal neutron flux at the filter/moderator exit can reach ∼8.5 x 109 n/cm2/s. When the collimator is added, the epithermal neutron beam intensity at the beam exit is reduced to 3 x 109 n/cm2/sec, but is still six times higher than the previous beam. Facing the clinical trials scheduled 3 and half years from now, a preliminary version of treatment planning system is developed. It includes a pre-processor to read CT scan and post-processors to display dose distributions. (author)

  14. Development and characteristics of the HANARO ex-core neutron irradiation facility for applications in the boron neutron capture therapy field

    CERN Document Server

    Kim, M S; Jun, B J; Kim, H; Lee, B C; Hwang, Sung-Yul; Jun, Byung-Jin; Kim, Heonil; Kim, Myong-Seop; Lee, Byung-Chul

    2006-01-01

    The HANARO ex-core neutron irradiation facility was developed for various applications in the boron neutron capture therapy (BNCT) field, and its characteristics have been investigated. In order to obtain a sufficient thermal neutron flux with a low level contamination of fast neutrons and gamma-rays, a radiation filtering method is adopted. The radiation filter has been designed by using a silicon single crystal cooled by liquid nitrogen and a bismuth crystal. The installation of the main components of the irradiation facility and the irradiation room are finished. Experimental measurements of the neutron beam characteristics have been performed by using bare and cadmium covered gold foils and wires. The in-phantom neutron flux distribution was measured for a flux mapping inside the phantom. The gamma-ray dose was determined by using TLD-700 thermoluminescence dosimeters. The thermal and fast neutron fluxes and the gamma-ray dose were calculated by using the MCNP code, and they were compared with experimenta...

  15. Comparison of intracerebral delivery of carboplatin and photon irradiation with an optimized regimen for boron neutron capture therapy of the F98 rat glioma

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Rolf F., E-mail: rolf.barth@osumc.edu [Department of Pathology, Ohio State University, 165 Hamilton Hall, 1645 Neil Avenue, Columbus, OH 43210 (United States); Yang Weilian; Huo Tianyao [Department of Pathology, Ohio State University, 165 Hamilton Hall, 1645 Neil Avenue, Columbus, OH 43210 (United States); Riley, Kent J.; Binns, Peter J. [Nuclear Reactor Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Grecula, John C., E-mail: john.grecula@osumc.edu [James Cancer Hospital and Solove Research Institute, Department of Radiation Oncology, Ohio State University, Columbus, OH, 43210 (United States); Gupta, Nilendu, E-mail: nilendu.gupta@osumc.edu [James Cancer Hospital and Solove Research Institute, Department of Radiation Oncology, Ohio State University, Columbus, OH, 43210 (United States); Rousseau, Julia, E-mail: julia.rousseau@yahoo.fr [INSERM, U836, Institute of Neurosciences, Grenoble (France); Elleaume, Helene, E-mail: h.elleaume@esrf.fr [INSERM, U836, Institute of Neurosciences, Grenoble (France)

    2011-12-15

    In this report we have summarized our studies to optimize the delivery of boronophenylalanine (BPA) and sodium borocaptate (BSH) for boron neutron capture therapy (BNCT) of F98 glioma bearing rats. These results have been compared to a chemoradiotherapeutic approach using the same tumor model. The best survival data from our BNCT studies were obtained using a combination of BPA and sodium borocaptate BSH administered via the internal carotid artery, in combination with blood-brain barrier disruption (BBB-D). This treatment resulted in a mean survival time (MST) of 140 d with a 25% cure rate. The other approach combined intracerebral administration of carboplatin by either convection enhanced delivery (CED) or Alzet pump infusion, followed by external beam photon irradiation. This resulted in MSTs of 83 d and 112 d, respectively, with a cure rate of 40% for the latter. However, a significant problem that must be solved for both BNCT and this new chemoradiotherapeutic approach is how to improve drug uptake and microdistribution within the tumor.

  16. Effect of the p53 gene status on the sensitivity of oral squamous cell carcinoma cells to boron neutron capture therapy

    International Nuclear Information System (INIS)

    The role of the p53 gene in the sensitivity of oral squamous cell carcinoma (SCC) to boron neutron capture therapy (BNCT) had not been studied. We examined the effect of boronophenylalanine (BPA)-mediated BNCT on oral SCC cells showing either wild-type p53 (SAS/neo) or mutated-type p53 (SAS/mp53). Survival ratio of cells was determined by colony formation. Cell viability was measured by MTT assay. Apoptotic cells were evaluated by flow cytometric analysis and nuclear DNA staining. When SAS/neo and SAS/mp53 cells were subjected to BNCT, more suppressive effects on colony formation and cell viability were observed in SAS/neo cells as compared with SAS/mp53. The proportion of apoptotic cells with DNA fragmentation was also increased in the cells with functional p53. These results suggest that oral SCC cells with mutated p53 cells are more resistant to BNCT than those with wild-type p53. BNCT must inhibit oral SCC cells in p53-dependent and p53-independent mechanisms. (author)

  17. Boron labeled rabbit anti-rat fibrin and goat anti-rabbit gamma globulin antibodies and their potential for slow neutron capture therapy of tumors

    International Nuclear Information System (INIS)

    The therapeutic effectiveness of slow neutron capture therapy is currently dependent upon achieving a high concentration gradient of boron between tumor and normal tissue. Labeling of anti-tumor or anti-tumor site antibodies with boron containing compounds could provide this high therapeutic value. Anti-rat fibrin antibodies, which show considerable localization at the site of several transplantable rat tumors, were labeled with 4-boronophenylalanine (4-BPA) using the N-carboxy anhydride procedure. Activity of these labeled antibodies was studied by modifying the test for fibrinogen concentration of hemophiliac blood. The number of 4-BPAs bound to each active antibody was determined indirectly using the fluorimetric test for phenylalanine concentration in serum. These tests showed that labeled antibodies retained their activity, and it was possible to add up to fifty 4-BPAs per active antibody. The indirect approach to achieving a high therapeutic value of boron was also investigated. This procedure involves labeling anti-immunoglobulin antibodies that bind to anti-tumor antibodies which are already bound to their respective antigens. Indirect labeling has the potential of increasing the therapeutic value by a factor of ten over the direct approach. Activity of labeled goat anti-rabbit gamma globulin (RGG) antibodies was studied by radial immunodiffusion and passive hemagglutination. The number of 4-BPAs bound to each active antibody was determined indirectly by fluorimetry. These labeled antibodies also retained their activity, and it was possible to add upwards of forty 4-BPAs per active antibody

  18. Gadolinium-loaded chitosan nanoparticles for neutron-capture therapy: Influence of micrometric properties of the nanoparticles on tumor-killing effect.

    Science.gov (United States)

    Ichikawa, Hideki; Uneme, Takeshi; Andoh, Tooru; Arita, Yuya; Fujimoto, Takuya; Suzuki, Minoru; Sakurai, Yoshinori; Shinto, Hiroyuki; Fukasawa, Tomonori; Fujii, Fumihiko; Fukumori, Yoshinobu

    2014-06-01

    As a nanoparticulate device for controlled delivery of Gd in NCT, the authors have developed gadolinium-loaded chitosan nanoparticles (Gd-nanoCPs). In the present study, influence of micrometric properties such as particle size, particle-surface charge and Gd content of Gd-nanoCPs on tumor-killing effect by Gd-NCT was investigated with Gd-nanoCPs. Two types of Gd-nanoCPs with different mean particle size, zeta potential and Gd-content (Gd-nanoCP-400; 391nm, 28mV, 9wt% and Gd-nanoCP-200; 214nm, 19mV, 24wt%) could be prepared by using chitosans with different molecular weights. Gd-nanoCPs incorporating 1.2mg of natural Gd were injected intratumorally once or twice to mice subcutaneously-bearing B16F10 melanoma. Eight hours after the last administration, thermal neutron was irradiated to tumor region of the mice. Remarkable tumor-growth was observed in both hot and cold control groups. In contrast, Gd-NCT groups showed significant tumor-growth suppression effect, though their efficacy was found to depend on the micrometric properties of Gd-nanoCPs. In particular, the Gd-nanoCP-200 exhibited stronger tumor-killing effect than the Gd-nanoCP-400 at the same Gd dose and it was still similar to Gd-nanoCP-400 in tumor-growth suppressing effect even at the half of Gd dose of Gd-nanoCP-400. This significance in tumor-killing effect would be ascribed from a higher Gd retention in the tumor tissue and an improved distribution of Gd with intratumorally administered Gd-nanoCP-200. Indeed, the Gd concentration in tumor tissue at the time corresponding to the onset of thermal neutron irradiation was determined to be significantly higher in Gd-nanoCP-200, compared with Gd-nanoCP-400. These results demonstrated that appropriate modification of Gd-nanoCPs in micrometric properties would be an effective way to improve the retention of Gd in the tumor tissue after intratumoral injection, leading to the enhanced tumor-killing effect in Gd-NCT.

  19. Monte-Carlo simulation of primary stochastic effects induced at the cellular level in boron neutron capture therapy; Simulation Monte-Carlo des effets stochastiques primaires induits au niveau cellulaire lors de la therapie par capture de neutrons sur le {sup 10}B

    Energy Technology Data Exchange (ETDEWEB)

    Cirioni, L.; Patau, J.P.; Nepveu, F. [Universite Paul Sabatier, 31 - Toulouse (France)

    1998-04-01

    A Monte Carlo code is developed to study the action of particles in Boron Neutron Capture Therapy (BNCT). Our aim is to calculate the probability of dissipating a lethal dose in cell nuclei. Cytoplasmic and nuclear membranes are considered as non-concentric ellipsoids. All geometrical parameters may be adjusted to fit actual configurations. The reactions {sup 10}B(n,{gamma} {alpha}){sup 7}Li and {sup 14}N(n,p) {sup 14}C create heavy ions which slow clown losing their energy. Their trajectories can be simulated taking into account path length straggling. The contribution of each reaction to the deposited dose in different cellular compartments can be studied and analysed for any distribution of {sup 10}B. (authors)

  20. Boron Neutron Capture Therapy in the Treatment of Locally Recurred Head-and-Neck Cancer: Final Analysis of a Phase I/II Trial

    Energy Technology Data Exchange (ETDEWEB)

    Kankaanranta, Leena [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland); Seppaelae, Tiina; Koivunoro, Hanna [Department of Physics, University of Helsinki, Helsinki (Finland); Boneca Corporation, Helsinki (Finland); Saarilahti, Kauko [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland); Atula, Timo [Department of Otorhinolaryngology, Helsinki University Central Hospital, Helsinki (Finland); Collan, Juhani [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland); Salli, Eero; Kortesniemi, Mika [Helsinki and Uusimaa Hospital District Medical Imaging Center, Helsinki University Central Hospital, Helsinki (Finland); Uusi-Simola, Jouni [Department of Physics, University of Helsinki, Helsinki (Finland); Helsinki and Uusimaa Hospital District Medical Imaging Center, Helsinki University Central Hospital, Helsinki (Finland); Vaelimaeki, Petteri [Department of Physics, University of Helsinki, Helsinki (Finland); Boneca Corporation, Helsinki (Finland); Maekitie, Antti [Department of Otorhinolaryngology, Helsinki University Central Hospital, Helsinki (Finland); Seppaenen, Marko [Turku PET Centre, Turku University Hospital, Turku (Finland); Minn, Heikki [Department of Oncology, Turku University Central Hospital, Turku (Finland); Revitzer, Hannu [Aalto University School of Science and Technology, Esopo (Finland); Kouri, Mauri [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland); Kotiluoto, Petri; Seren, Tom; Auterinen, Iiro [VTT Technical Research Centre of Finland, Espoo (Finland); Savolainen, Sauli [Department of Physics, University of Helsinki, Helsinki (Finland); Helsinki and Uusimaa Hospital District Medical Imaging Center, Helsinki University Central Hospital, Helsinki (Finland); Joensuu, Heikki, E-mail: heikki.joensuu@hus.fi [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland)

    2012-01-01

    Purpose: To investigate the efficacy and safety of boron neutron capture therapy (BNCT) in the treatment of inoperable head-and-neck cancers that recur locally after conventional photon radiation therapy. Methods and Materials: In this prospective, single-center Phase I/II study, 30 patients with inoperable, locally recurred head-and-neck cancer (29 carcinomas and 1 sarcoma) were treated with BNCT. Prior treatments consisted of surgery and conventionally fractionated photon irradiation to a cumulative dose of 50 to 98 Gy administered with or without concomitant chemotherapy. Tumor responses were assessed by use of the RECIST (Response Evaluation Criteria in Solid Tumors) and adverse effects by use of the National Cancer Institute common terminology criteria version 3.0. Intravenously administered L-boronophenylalanine-fructose (400 mg/kg) was administered as the boron carrier. Each patient was scheduled to be treated twice with BNCT. Results: Twenty-six patients received BNCT twice; four were treated once. Of the 29 evaluable patients, 22 (76%) responded to BNCT, 6 (21%) had tumor growth stabilization for 5.1 and 20.3 months, and 1 (3%) progressed. The median progression-free survival time was 7.5 months (95% confidence interval, 5.4-9.6 months). Two-year progression-free survival and overall survival were 20% and 30%, respectively, and 27% of the patients survived for 2 years without locoregional recurrence. The most common acute Grade 3 adverse effects were mucositis (54% of patients), oral pain (54%), and fatigue (32%). Three patients were diagnosed with osteoradionecrosis (each Grade 3) and one patient with soft-tissue necrosis (Grade 4). Late Grade 3 xerostomia was present in 3 of the 15 evaluable patients (20%). Conclusions: Most patients who have inoperable, locally advanced head-and-neck carcinoma that has recurred at a previously irradiated site respond to boronophenylalanine-mediated BNCT, but cancer recurrence after BNCT remains frequent. Toxicity was

  1. Boron Neutron Capture Therapy (BNCT) in an Oral Precancer Model: Therapeutic Benefits and Potential Toxicity of a Double Application of BNCT with a Six-Week Interval

    International Nuclear Information System (INIS)

    Given the clinical relevance of locoregional recurrences in head and neck cancer, we developed a novel experimental model of premalignant tissue in the hamster cheek pouch for long-term studies and demonstrated the partial inhibitory effect of a single application of Boron Neutron Capture Therapy (BNCT) on tumor development from premalignant tissue. The aim of the present study was to evaluate the effect of a double application of BNCT with a 6 week interval in terms of inhibitory effect on tumor development, toxicity and DNA synthesis. We performed a double application, 6 weeks apart, of (1) BNCT mediated by boronophenylalanine (BPA-BNCT); (2) BNCT mediated by the combined application of decahydrodecaborate (GB-10) and BPA ((GB-10 + BPA)-BNCT) or (3) beam-only, at RA-3 nuclear reactor and followed the animals for 8 months. The control group was cancerized and sham-irradiated. BPA-BNCT, (GB- 10 + BPA)-BNCT and beam-only induced a reduction in tumor development from premalignant tissue that persisted until 8, 3, and 2 months respectively. An early maximum inhibition of 100% was observed for all 3 protocols. No normal tissue radiotoxicity was detected. Reversible mucositis was observed in premalignant tissue, peaking at 1 week and resolving by the third week after each irradiation. Mucositis after the second application was not exacerbated by the first application. DNA synthesis was significantly reduced in premalignant tissue 8 months post-BNCT. A double application of BPA-BNCT and (GB-10 + BPA)-BNCT, 6 weeks apart, could be used therapeutically at no additional cost in terms of radiotoxicity in normal and dose-limiting tissues.

  2. The potential of transferrin-pendant-type polyethyleneglycol liposomes encapsulating decahydrodecaborate-1B (GB-10) as 1B-carriers for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Purpose: To evaluate GB-10-encapsulating transferrin (TF)-pendant-type polyethyleneglycol (PEG) liposomes as tumor-targeting 1B-carriers for boron neutron capture therapy. Methods and Materials: A free mercaptoundecahydrododecaborate-1B (BSH) or decahydrodecaborate-1B (GB-10) solution, bare liposomes, PEG liposomes, or TF-PEG liposomes were injected into SCC VII tumor-bearing mice, and 1B concentrations in the tumors and normal tissues were measured by γ-ray spectrometry. Meanwhile, tumor-bearing mice were continuously given 5-bromo-2'-deoxyuridine (BrdU) to label all intratumor proliferating cells, then injected with these 1B-carriers containing BSH or GB-10 in the same manner. Right after thermal neutron irradiation, the response of quiescent (Q) cells was assessed in terms of the micronucleus frequency using immunofluorescence staining for BrdU. The frequency in the total tumor cells was determined from the BrdU nontreated tumors. Results: Transferrin-PEG liposomes showed a prolonged retention in blood circulation, low uptake by reticuloendothelial system, and the most enhanced accumulation of 1B in solid tumors. In general, the enhancing effects were significantly greater in total cells than Q cells. In both cells, the enhancing effects of GB-10-containing 1B-carriers were significantly greater than BSH-containing 1B-carriers, whether loaded in free solution or liposomes. In both cells, whether BSH or GB-10 was employed, the greatest enhancing effect was observed with TF-PEG liposomes followed in decreasing order by PEG liposomes, bare liposomes, and free BSH or GB-10 solution. In Q cells, the decrease was remarkable between PEG and bare liposomes. Conclusions: In terms of biodistribution characteristics and tumor cell-killing effect as a whole, including Q cells, GB-10 TF-PEG liposomes were regarded as promising 1B-carriers

  3. Impact of intra-arterial administration of boron compounds on dose-volume histograms in boron neutron capture therapy for recurrent head-and-neck tumors

    International Nuclear Information System (INIS)

    Purpose: To analyze the dose-volume histogram (DVH) of head-and-neck tumors treated with boron neutron capture therapy (BNCT) and to determine the advantage of the intra-arterial (IA) route over the intravenous (IV) route as a drug delivery system for BNCT. Methods and Materials: Fifteen BNCTs for 12 patients with recurrent head-and-neck tumors were included in the present study. Eight irradiations were done after IV administration of boronophenylalanine and seven after IA administration. The maximal, mean, and minimal doses given to the gross tumor volume were assessed using a BNCT planning system. Results: The results are reported as median values with the interquartile range. In the IA group, the maximal, mean, and minimal dose given to the gross tumor volume was 68.7 Gy-Eq (range, 38.8-79.9), 45.0 Gy-Eq (range, 25.1-51.0), and 13.8 Gy-Eq (range, 4.8-25.3), respectively. In the IV group, the maximal, mean, and minimal dose given to the gross tumor volume was 24.2 Gy-Eq (range, 21.5-29.9), 16.4 Gy-Eq (range, 14.5-20.2), and 7.8 Gy-Eq (range, 6.8-9.5), respectively. Within 1-3 months after BNCT, the responses were assessed. Of the 6 patients in the IV group, 2 had a partial response, 3 no change, and 1 had progressive disease. Of 4 patients in the IA group, 1 achieved a complete response and 3 a partial response. Conclusion: Intra-arterial administration of boronophenylalanine is a promising drug delivery system for head-and-neck BNCT

  4. Tumor development in field-cancerized tissue is inhibited by a double application of Boron neutron capture therapy (BNCT) without exceeding radio-tolerance

    International Nuclear Information System (INIS)

    Introduction: BNCT is based on the capture reaction between boron, selectively targeted to tumor tissue, and thermal neutrons which gives rise to lethal, short-range high linear energy transfer particles that selectively damage tumor tissue, sparing normal tissue. We previously evidenced a remarkable therapeutic success of a 'single' application of boron neutron capture therapy (BNCT) mediated by boronophenylalanine (BPA), GB-1(Na210B10H10) or (GB-10+BPA) to treat hamster cheek pouch tumors with no normal tissue radiotoxicity. Based on these results, we developed a model of precancerous tissue in the hamster cheek pouch for long-term studies. Employing this model we evaluated the long-term potential inhibitory effect on the development of second primary tumors from precancerous tissue and eventual radiotoxicity of a single application of BNCT mediated by BPA, GB-10 or (GB-10+BPA), in the RA-6. The clinical rationale of this study was to search for a BNCT protocol that is therapeutic for tumor, not radio-toxic for the normal tissue that lies in the neutron beam path, and exerts the desired inhibitory effect on the development of second primary tumors, without exceeding the radio-tolerance of precancerous tissue, the dose limiting tissue in this case. Second primary tumors that arise in precancerous tissue (also called locoregional recurrences) are a frequent cause of therapeutic failure in head and neck tumors. Aim: Evaluate the radiotoxicity and inhibitory effect of a 'double' application of the same BNCT protocols that were proved therapeutically successful for tumor and precancerous tissue, with a long term follow up (8 months). A 'double' application of BNCT is a potentially useful strategy for the treatment of tumors, in particular the larger ones, but the cost in terms of side-effects in dose-limiting tissues might preclude its application and requires cautious evaluation. Materials and methods: We performed a double application of 1) BPA-BNCT; 2) (GB- 10+BPA

  5. SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, D; Jung, J; Suh, T [The Catholic University of Korea, College of medicine, Department of biomedical engineering (Korea, Republic of)

    2014-06-01

    Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research

  6. Experimental Studies of Boronophenylalanine ({sup 10}BPA) Biodistribution for the Individual Application of Boron Neutron Capture Therapy (BNCT) for Malignant Melanoma Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Carpano, Marina; Perona, Marina; Rodriguez, Carla [Department of Radiobiology, National Atomic Energy Commission, San Martín (Argentina); Nievas, Susana; Olivera, Maria; Santa Cruz, Gustavo A. [Department of Boron Neutron Capture Therapy, National Atomic Energy Commission, San Martín (Argentina); Brandizzi, Daniel; Cabrini, Romulo [Department of Radiobiology, National Atomic Energy Commission, San Martín (Argentina); School of Dentistry, University of Buenos Aires, Buenos Aires (Argentina); Pisarev, Mario [Department of Radiobiology, National Atomic Energy Commission, San Martín (Argentina); National Research Council of Argentina, Buenos Aires (Argentina); Department of Human Biochemistry, School of Medicine, University of Buenos Aires, Buenos Aires (Argentina); Juvenal, Guillermo Juan [Department of Radiobiology, National Atomic Energy Commission, San Martín (Argentina); National Research Council of Argentina, Buenos Aires (Argentina); Dagrosa, Maria Alejandra, E-mail: dagrosa@cnea.gov.ar [Department of Radiobiology, National Atomic Energy Commission, San Martín (Argentina); National Research Council of Argentina, Buenos Aires (Argentina)

    2015-10-01

    Purpose: Patients with the same histopathologic diagnosis of cutaneous melanoma treated with identical protocols of boron neutron capture therapy (BNCT) have shown different clinical outcomes. The objective of the present studies was to evaluate the biodistribution of boronophenilalanina ({sup 10}BPA) for the potential application of BNCT for the treatment of melanoma on an individual basis. Methods and Materials: The boronophenilalanine (BPA) uptake was evaluated in 3 human melanoma cell lines: MEL-J, A375, and M8. NIH nude mice were implanted with 4 10{sup 6} MEL-J cells, and biodistribution studies of BPA (350 mg/kg intraperitoneally) were performed. Static infrared imaging using a specially modified infrared camera adapted to measure the body infrared radiance of small animals was used. Proliferation marker, Ki-67, and endothelial marker, CD31, were analyzed in tumor samples. Results: The in vitro studies demonstrated different patterns of BPA uptake for each analyzed cell line (P<.001 for MEL-J and A375 vs M8 cells). The in vivo studies showed a maximum average boron concentration of 25.9 ± 2.6 μg/g in tumor, with individual values ranging between 11.7 and 52.0 μg/g of {sup 10}B 2 hours after the injection of BPA. Tumor temperature always decreased as the tumors increased in size, with values ranging between 37°C and 23°C. A significant correlation between tumor temperature and tumor-to-blood boron concentration ratio was found (R{sup 2} = 0.7, rational function fit). The immunohistochemical studies revealed, in tumors with extensive areas of viability, a high number of positive cells for Ki-67, blood vessels of large diameter evidenced by the marker CD31, and a direct logistic correlation between proliferative status and boron concentration difference between tumor and blood (R{sup 2} = 0.81, logistic function fit). Conclusion: We propose that these methods could be suitable for designing new screening protocols applied before melanoma BNCT

  7. Sodium borocaptate (BSH) for Boron Neutron Capture Therapy (BNCT) in the hamster cheek pouch oral cancer model: boron biodistribution at 9 post administration time-points

    International Nuclear Information System (INIS)

    The therapeutic success of Boron Neutron Capture Therapy (BNCT) depends centrally on boron concentration in tumor and healthy tissue. We previously demonstrated the therapeutic efficacy of boronophenylalanine (BPA) and sodium decahydrodecaborate (GB-10) as boron carriers for BNCT in the hamster cheek pouch oral cancer model. Given the clinical relevance of sodium mercaptoundecahydro-closo-dodecaborate (BSH) as a boron carrier, the aim of the present study was to expand the ongoing BSH biodistribution studies in the hamster cheek pouch oral cancer model. In particular, we studied 3 additional post-administration time-points and increased the sample size corresponding to the time-points evaluated previously, to select more accurately the post-administration time at which neutron irradiation would potentially confer the greatest therapeutic advantage. BSH was dissolved in saline solution in anaerobic conditions to avoid the formation of the dimer BSSB and its oxides which are toxic. The solution was injected intravenously at a dose of 50 mg 10 B/kg (88 mg BSH / kg). Different groups of animals were killed humanely at 7, 8, and 10 h after administration of BSH. The sample size corresponding to the time-points 3, 4, 6, 9 and 12 h was increased. Samples of blood, tumor, precancerous tissue, normal pouch tissue, cheek mucosa, parotid gland, palate, skin, tongue, spinal cord marrow, brain, liver, kidney, spleen and lung were processed for boron measurement by Optic Emission Spectroscopy (ICP-OES). Boron concentration in tumor peaked to 24-34 ppm, 3-10 h post-administration of BSH, with a spread in values that resembled that previously reported in other experimental models and human subjects. The boron concentration ratios tumor/normal pouch tissue and tumor/blood ranged from 1.3 to 1.8. No selective tumor uptake was observed at any of the time points evaluated. The times post-administration of BSH that would be therapeutically most useful would be 5, 7 and 9 h. The

  8. Experimental Studies of Boronophenylalanine (10BPA) Biodistribution for the Individual Application of Boron Neutron Capture Therapy (BNCT) for Malignant Melanoma Treatment

    International Nuclear Information System (INIS)

    Purpose: Patients with the same histopathologic diagnosis of cutaneous melanoma treated with identical protocols of boron neutron capture therapy (BNCT) have shown different clinical outcomes. The objective of the present studies was to evaluate the biodistribution of boronophenilalanina (10BPA) for the potential application of BNCT for the treatment of melanoma on an individual basis. Methods and Materials: The boronophenilalanine (BPA) uptake was evaluated in 3 human melanoma cell lines: MEL-J, A375, and M8. NIH nude mice were implanted with 4 106 MEL-J cells, and biodistribution studies of BPA (350 mg/kg intraperitoneally) were performed. Static infrared imaging using a specially modified infrared camera adapted to measure the body infrared radiance of small animals was used. Proliferation marker, Ki-67, and endothelial marker, CD31, were analyzed in tumor samples. Results: The in vitro studies demonstrated different patterns of BPA uptake for each analyzed cell line (P<.001 for MEL-J and A375 vs M8 cells). The in vivo studies showed a maximum average boron concentration of 25.9 ± 2.6 μg/g in tumor, with individual values ranging between 11.7 and 52.0 μg/g of 10B 2 hours after the injection of BPA. Tumor temperature always decreased as the tumors increased in size, with values ranging between 37°C and 23°C. A significant correlation between tumor temperature and tumor-to-blood boron concentration ratio was found (R2 = 0.7, rational function fit). The immunohistochemical studies revealed, in tumors with extensive areas of viability, a high number of positive cells for Ki-67, blood vessels of large diameter evidenced by the marker CD31, and a direct logistic correlation between proliferative status and boron concentration difference between tumor and blood (R2 = 0.81, logistic function fit). Conclusion: We propose that these methods could be suitable for designing new screening protocols applied before melanoma BNCT treatment for each individual

  9. SU-E-J-100: Reconstruction of Prompt Gamma Ray Three Dimensional SPECT Image From Boron Neutron Capture Therapy(BNCT)

    International Nuclear Information System (INIS)

    Purpose: Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography (SPECT) image from boron neutron capture therapy (BNCT) using Monte Carlo simulation. Methods: In case of simulation, the pixelated SPECT detector, collimator and phantom were simulated using Monte Carlo n particle extended (MCNPX) simulation tool. A thermal neutron source (<1 eV) was used to react with the boron uptake region (BUR) in the phantom. Each geometry had a spherical pattern, and three different BURs (A, B and C region, density: 2.08 g/cm3) were located in the middle of the brain phantom. The data from 128 projections for each sorting process were used to achieve image reconstruction. The ordered subset expectation maximization (OSEM) reconstruction algorithm was used to obtain a tomographic image with eight subsets and five iterations. The receiver operating characteristic (ROC) curve analysis was used to evaluate the geometric accuracy of reconstructed image. Results: The OSEM image was compared with the original phantom pattern image. The area under the curve (AUC) was calculated as the gross area under each ROC curve. The three calculated AUC values were 0.738 (A region), 0.623 (B region), and 0.817 (C region). The differences between length of centers of two boron regions and distance of maximum count points were 0.3 cm, 1.6 cm and 1.4 cm. Conclusion: The possibility of extracting a 3D BNCT SPECT image was confirmed using the Monte Carlo simulation and OSEM algorithm. The prospects for obtaining an actual BNCT SPECT image were estimated from the quality of the simulated image and the simulation conditions. When multiple tumor region should be treated using the BNCT, a reasonable model to determine how many useful images can be obtained from the SPECT could be provided to the BNCT facilities. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research

  10. Laser capture.

    Science.gov (United States)

    Potter, S Steven; Brunskill, Eric W

    2012-01-01

    This chapter describes detailed methods used for laser capture microdissection (LCM) of discrete subpopulations of cells. Topics covered include preparing tissue blocks, cryostat sectioning, processing slides, performing the LCM, and purification of RNA from LCM samples. Notes describe the fine points of each operation, which can often mean the difference between success and failure. PMID:22639264

  11. Toward a clinical application of ex situ boron neutron capture therapy for lung tumors at the RA-3 reactor in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Farías, R. O.; Trivillin, V. A.; Portu, A. M.; Schwint, A. E.; González, S. J., E-mail: srgonzal@cnea.gov.ar [Comisión Nacional de Energía Atómica (CNEA), San Martín 1650, Argentina and Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Buenos Aires 1033 (Argentina); Garabalino, M. A.; Monti Hughes, A.; Pozzi, E. C. C.; Thorp, S. I.; Curotto, P.; Miller, M. E.; Santa Cruz, G. A.; Saint Martin, G. [Comisión Nacional de Energía Atómica (CNEA), San Martín 1650 (Argentina); Ferraris, S.; Santa María, J.; Rovati, O.; Lange, F. [CIDME, Universidad Maimónides, Buenos Aires 1405 (Argentina); Bortolussi, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Pavia 27100 (Italy); Altieri, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Pavia 27100, Italy and Dipartimento di Fisica, Università di Pavia, Pavia 27100 (Italy)

    2015-07-15

    Purpose: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (L)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. Methods: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. Results: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect

  12. Apoptosis of human melanoma cells induced by boron neutron capture therapy%硼中子俘获疗法促人黑色素瘤细胞凋亡

    Institute of Scientific and Technical Information of China (English)

    孙婷; 丁大冬; 李斌; 陈桂林; 韦永新; 谢学顺; 杨天权; 吴庭枫; 周幽心

    2013-01-01

    目的 研究硼中子俘获疗法(BNCT)体外杀伤人黑色素瘤细胞的效应及机制.方法 首先检测黑色素瘤细胞A375吸收含硼化合物二羟基苯丙氨酸硼(BPA)的情况,然后采用医院中子照射器(IHNI-1)对含硼(10B)细胞进行照射.克隆存活实验检测细胞的放射敏感性,MTT法检测细胞增殖率,流式细胞术检测凋亡,Western blot检测胞质内细胞色素C表达和caspase-9的激活.结果 BPA孵育24 h,A375细胞10B浓度为(2.884±0.148)μg/107个细胞,达到了BNCT杀伤细胞的要求.富含10B的细胞经中子照射2.1 min后存活分数降低为对照组的58%(t=2.964,P<0.05),细胞经中子照射后24 h增殖率下降为对照组的83%(t=3.286,P<0.05),BNCT组细胞凋亡率达(55.2±7.9)%,明显高于对照组(t =9.754,P<0.05),胞质内细胞色素C水平上升且caspase-9激活程度增加(t=7.625、8.307,P<0.05).结论 BNCT能够杀伤黑色素瘤细胞,其机制可能通过线粒体途径诱导细胞凋亡.%Objective To study the effect and underlying mechanism of boron neutron capture therapy (BNCT) on human melanoma cells.Methods The situation of boronophenylalanine (BPA) uptake of human melanoma cells A375 was detected and then the boron-10 (10B) enriched cells were irradiated by an in-hospital neutron irradiator (IHNI-1).The radiation sensitivity was measured using clonogenic survival assay,the proliferation was examined by MTT assay,apoptosis was determined using flow cytometry,and the protein expression of cytochrome C in cytosol and activation of caspase-9 was detected by Western blot.Results 10B concentration in A375 cells approached to (2.884 ± 0.148)μg/107 cells after 24 h culture with BPA,which met the requirement of BNCT.At 2.1 min after neutron radiation,the survival fraction of BNCT group was decreased to 58% of control (t =2.964,P < 0.05).At 24 h after BNCT,the cell viability was decreased to 83% of control (t =3.286,P < 0.05),the apoptosis ratio was (55.2 ± 7

  13. Optimal moderator materials at various proton energies considering photon dose rate after irradiation for an accelerator-driven ⁹Be(p, n) boron neutron capture therapy neutron source.

    Science.gov (United States)

    Hashimoto, Y; Hiraga, F; Kiyanagi, Y

    2015-12-01

    We evaluated the accelerator beam power and the neutron-induced radioactivity of (9)Be(p, n) boron neutron capture therapy (BNCT) neutron sources having a MgF2, CaF2, or AlF3 moderator and driven by protons with energy from 8 MeV to 30 MeV. The optimal moderator materials were found to be MgF2 for proton energies less than 10 MeV because of lower required accelerator beam power and CaF2 for higher proton energies because of lower photon dose rate at the treatment position after neutron irradiation.

  14. L-Phenylalanine preloading reduces the (10)B(n, α)(7)Li dose to the normal brain by inhibiting the uptake of boronophenylalanine in boron neutron capture therapy for brain tumours.

    Science.gov (United States)

    Watanabe, Tsubasa; Tanaka, Hiroki; Fukutani, Satoshi; Suzuki, Minoru; Hiraoka, Masahiro; Ono, Koji

    2016-01-01

    Boron neutron capture therapy (BNCT) is a cellular-level particle radiation therapy that combines the selective delivery of boron compounds to tumour tissue with neutron irradiation. Previously, high doses of one of the boron compounds used for BNCT, L-BPA, were found to reduce the boron-derived irradiation dose to the central nervous system. However, injection with a high dose of L-BPA is not feasible in clinical settings. We aimed to find an alternative method to improve the therapeutic efficacy of this therapy. We examined the effects of oral preloading with various analogues of L-BPA in a xenograft tumour model and found that high-dose L-phenylalanine reduced the accumulation of L-BPA in the normal brain relative to tumour tissue. As a result, the maximum irradiation dose in the normal brain was 19.2% lower in the L-phenylalanine group relative to the control group. This study provides a simple strategy to improve the therapeutic efficacy of conventional boron compounds for BNCT for brain tumours and the possibility to widen the indication of BNCT to various kinds of other tumours.

  15. Project for the development of the linac based NCT facility in University of Tsukuba.

    Science.gov (United States)

    Kumada, H; Matsumura, A; Sakurai, H; Sakae, T; Yoshioka, M; Kobayashi, H; Matsumoto, H; Kiyanagi, Y; Shibata, T; Nakashima, H

    2014-06-01

    A project team headed by University of Tsukuba launched the development of a new accelerator based BNCT facility. In the project, we have adopted Radio-Frequency Quadrupole (RFQ)+Drift Tube Linac (DTL) type linac as proton accelerators. Proton energy generated from the linac was set to 8MeV and average current was 10mA. The linac tube has been constructed by Mitsubishi Heavy Industry Co. For neutron generator device, beryllium is selected as neutron target material; high intensity neutrons are generated by the reaction with beryllium and the 80kW proton beam. Our team chose beryllium as the neutron target material. At present beryllium target system is being designed with Monte-Carlo estimations and heat analysis with ANSYS. The neutron generator consists of moderator, collimator and shielding. It is being designed together with the beryllium target system. We also acquired a building in Tokai village; the building has been renovated for use as BNCT treatment facility. It is noteworthy that the linac tube had been installed in the facility in September 2012. In BNCT procedure, several medical devices are required for BNCT treatment such as treatment planning system, patient positioning device and radiation monitors. Thus these are being developed together with the linac based neutron source. For treatment planning system, we are now developing a new multi-modal Monte-Carlo treatment planning system based on JCDS. The system allows us to perform dose estimation for BNCT as well as particle radiotherapy and X-ray therapy. And the patient positioning device can navigate a patient to irradiation position quickly and properly. Furthermore the device is able to monitor movement of the patient׳s position during irradiation.

  16. Project for the development of the linac based NCT facility in University of Tsukuba

    International Nuclear Information System (INIS)

    A project team headed by University of Tsukuba launched the development of a new accelerator based BNCT facility. In the project, we have adopted Radio-Frequency Quadrupole (RFQ)+Drift Tube Linac (DTL) type linac as proton accelerators. Proton energy generated from the linac was set to 8 MeV and average current was 10 mA. The linac tube has been constructed by Mitsubishi Heavy Industry Co. For neutron generator device, beryllium is selected as neutron target material; high intensity neutrons are generated by the reaction with beryllium and the 80 kW proton beam. Our team chose beryllium as the neutron target material. At present beryllium target system is being designed with Monte-Carlo estimations and heat analysis with ANSYS. The neutron generator consists of moderator, collimator and shielding. It is being designed together with the beryllium target system. We also acquired a building in Tokai village; the building has been renovated for use as BNCT treatment facility. It is noteworthy that the linac tube had been installed in the facility in September 2012. In BNCT procedure, several medical devices are required for BNCT treatment such as treatment planning system, patient positioning device and radiation monitors. Thus these are being developed together with the linac based neutron source. For treatment planning system, we are now developing a new multi-modal Monte-Carlo treatment planning system based on JCDS. The system allows us to perform dose estimation for BNCT as well as particle radiotherapy and X-ray therapy. And the patient positioning device can navigate a patient to irradiation position quickly and properly. Furthermore the device is able to monitor movement of the patient's position during irradiation. - Highlights: • A project team headed by University of Tsukuba launched a development of new accelerator based BNCT facility. • The project adopted an 8 MeV RFQ+DTL type linac as proton accelerator. • The linac tube is completed and

  17. Computerized axial tomographic and magnetic resonance imaging scan follow-up of two patients after boron neutron capture therapy for Glioblastoma Multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Marano, S.R.; Spickard, J.H.; Griebenow, M.L.

    1988-01-01

    Using computer tomography (CT) and magnetic resonance imaging (MRI), we are following a 30-year old, white female and a 64-year old, white female and a 64-year old, white male, both with biopsy-proven Glioblastoma Multiforme, from their preoperative through post-operative stages and pre- and post-BNCT treatment. The images visually demonstrate the evolving changes in the tumor and surrounding cortex. These patients were treated by Hiroshi Hatanaka of Teikyo University, at the Musashi Institute of Technology (MIT) reactor which is a 100 kW Triga-II facility that has been used by Hatanaka for many years for BNCT therapy. 10 figs.

  18. Computerized axial tomographic and magnetic resonance imaging scan follow-up of two patients after boron neutron capture therapy for Glioblastoma Multiforme

    Energy Technology Data Exchange (ETDEWEB)

    Marano, S.R.; Spickard, J.H.; Griebenow, M.L.

    1988-01-01

    Using computed tomography (CT) and magnetic resonance imaging (MRI), we are following a 30-year old, white female and a 64-year old, white female and a 64-year old, white male, both with biopsy-proven Glioblastoma Multiforme, from their preoperative through post-operative stages and pre- and post-BNCT treatment. The images visually demonstrate the evolving changes in the tumor and surrounding cortex. These patients were treated by Hiroshi Hatanaka of Teikyo University, at the Musashi Institute of Technology (MIT) reactor is a 100 kW Triga-II facility that has been used by Hatanaka for many years for BNCT therapy. 7 figs.

  19. Synovectomy by Neutron capture

    International Nuclear Information System (INIS)

    The Synovectomy by Neutron capture has as purpose the treatment of the rheumatoid arthritis, illness which at present does not have a definitive curing. This therapy requires a neutron source for irradiating the articulation affected. The energy spectra and the intensity of these neutrons are fundamental since these neutrons induce nuclear reactions of capture with Boron-10 inside the articulation and the freely energy of these reactions is transferred at the productive tissue of synovial liquid, annihilating it. In this work it is presented the neutron spectra results obtained with moderator packings of spherical geometry which contains in its center a Pu239 Be source. The calculations were realized through Monte Carlo method. The moderators assayed were light water, heavy water base and the both combination of them. The spectra obtained, the average energy, the neutron total number by neutron emitted by source, the thermal neutron percentage and the dose equivalent allow us to suggest that the moderator packing more adequate is what has a light water thickness 0.5 cm (radius 2 cm) and 24.5 cm heavy water (radius 26.5 cm). (Author)

  20. Basic research of boron neutron-capture therapy for treatment of pancreatic cancer. Application of neutron radiography for visualization of boron compound on BNCT

    International Nuclear Information System (INIS)

    The cytotoxic effects of locally injected 10B-immunoliposomes (anti-CEA) on human pancreatic carcinoma xenografts in nude mice were evaluated with thermal neutron irradiation. After thermal neutron irradiation of mice injected with 10B-immunoliposomes, AsPC-1 tumour growth was suppressed relative to controls. Histopathologically, hyalinization and necrosis were found in 10B-treated tumours, while tumour tissue injected with saline or saline-containing immunoliposomes showed neither destruction nor necrosis. These results suggest that intratumoral injection of boronated immunoliposomes can increase the retention of 10B atoms by tumour cells, causing tumour growth suppression in vivo upon thermal neutron irradiation. We prepared boronated PEG-binding bovine serum albumin (10B-PEG-BSA). 10B concentrations in AsPC-1, human pancreatic cancer cells (2 x 105 /well) obtained 24 hrs after incubation with 10B-PEG-BSA was 13.01 ± 1.74 ppm. The number of 10B atoms delivered to the tumor cells was calculated to be 7.83 x 1011 at 24 hrs after incubation with 10B-PEG-BSA. These data indicated that the 10B-PEG-BSA could deliver a sufficient amount of 10B atoms (more than 109 atoms/cell) to the tumor cells to induce cytotoxic effects after incubation upon thermal neutron irradiation. Neutron capture autoradiography by using an Imaging Plate (IP-NCR) was performed on AsPC-1 tumor-bearing mouse that had been given an intratumoral injection of 10B-PEG BSA or 10B-cationic liposome. We had demonstrated the 10B-PEG BSA or 10B-cationic liposome is taken up by AsPC-1 tumor tissue to a much greater extent than by normal tissues. (J.P.N.)

  1. Basic research of boron neutron-capture therapy for treatment of pancreatic cancer. Application of neutron radiography for visualization of boron compound on BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Yanagie, Hironobu [Tokyo Univ. (Japan). Inst. of Medical Science

    1997-02-01

    The cytotoxic effects of locally injected {sup 10}B-immunoliposomes (anti-CEA) on human pancreatic carcinoma xenografts in nude mice were evaluated with thermal neutron irradiation. After thermal neutron irradiation of mice injected with {sup 10}B-immunoliposomes, AsPC-1 tumour growth was suppressed relative to controls. Histopathologically, hyalinization and necrosis were found in {sup 10}B-treated tumours, while tumour tissue injected with saline or saline-containing immunoliposomes showed neither destruction nor necrosis. These results suggest that intratumoral injection of boronated immunoliposomes can increase the retention of {sup 10}B atoms by tumour cells, causing tumour growth suppression in vivo upon thermal neutron irradiation. We prepared boronated PEG-binding bovine serum albumin ({sup 10}B-PEG-BSA). {sup 10}B concentrations in AsPC-1, human pancreatic cancer cells (2 x 10{sup 5} /well) obtained 24 hrs after incubation with {sup 10}B-PEG-BSA was 13.01 {+-} 1.74 ppm. The number of {sup 10}B atoms delivered to the tumor cells was calculated to be 7.83 x 10{sup 11} at 24 hrs after incubation with {sup 10}B-PEG-BSA. These data indicated that the {sup 10}B-PEG-BSA could deliver a sufficient amount of {sup 10}B atoms (more than 10{sup 9} atoms/cell) to the tumor cells to induce cytotoxic effects after incubation upon thermal neutron irradiation. Neutron capture autoradiography by using an Imaging Plate (IP-NCR) was performed on AsPC-1 tumor-bearing mouse that had been given an intratumoral injection of {sup 10}B-PEG BSA or {sup 10}B-cationic liposome. We had demonstrated the {sup 10}B-PEG BSA or {sup 10}B-cationic liposome is taken up by AsPC-1 tumor tissue to a much greater extent than by normal tissues. (J.P.N.)

  2. Neutron-photon mixed field dosimetry by TLD-700 glow curve analysis and its implementation in dose monitoring for Boron Neutron Capture Therapy (BNCT) treatments

    International Nuclear Information System (INIS)

    BNCT is a cancerous cells selective, non-conventional radiotherapy modality to treat malignant tumors such as glioblastoma, melanoma and recurrent head and neck cancer. It consists of a two-step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope (Boron-10) with high slow neutron capture cross-section. In a second step, the patient is irradiated with neutrons, which are absorbed by the Boron-10 agent with the subsequently nuclear reaction B- 10(n,a)Li-7, thereby resulting in dose at cellular level due to the high-Let particles. The neutron fields suitable for BNCT are characterized by high neutron fluxes and low gamma dose. Determination of each component is not an easy task, especially when the volume of measurement is quite small or inaccessible for a miniature ionization chamber, for example. A method of measuring the photon and slow neutron dose(mainly by N-14 and B-10) from the glow curve (GC) analysis of a single 7LiF thermoluminescence detector is evaluated. This method was suggested by the group headed by Dr. Grazia Gambarini. The dosemeters used were TLD-600 (6LiF:Mg,Ti with 95.6% 6Li) and TLD-700 (7LiF:Mg,Ti with 99.9% 7LiF) from Harshaw. Photon dose measurement using the GC analysis method with TLD-700 in mixed fields requires the relation of the two main peaks of a TLD-600 GC shape obtained from an exposition to the same neutron field, and a photon calibrated GC with TLD-700. The requirements for slow neutron dose measurements are similar. In order to properly apply the GC analysis method at the Ra-6 Research Reactor BNCT facility, measurements were carried out in a standard water phantom, fully characterized on the BNCT beam by conventional techniques (activation detectors and paired ionization chambers technique). Next, the method was implemented in whole body dose monitoring of a patient undergoing a BNCT treatment, using a Bo MAb (Bottle Manikin Absorption) phantom, with representative

  3. Neutron-photon mixed field dosimetry by TLD-700 glow curve analysis and its implementation in dose monitoring for Boron Neutron Capture Therapy (BNCT) treatments

    Energy Technology Data Exchange (ETDEWEB)

    Boggio, E. F.; Longhino, J. M. [Centro Atomico Bariloche, Departamento de Fisica de Reactores y Radiaciones / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina); Andres, P. A., E-mail: efboggio@cab.cnea.gov.ar [Centro Atomico Bariloche, Division Proteccion Radiologica / CNEA, Av. E. Bustillo Km 9.5, R8402AGP San Carlos de Bariloche (Argentina)

    2015-10-15

    BNCT is a cancerous cells selective, non-conventional radiotherapy modality to treat malignant tumors such as glioblastoma, melanoma and recurrent head and neck cancer. It consists of a two-step procedure: first, the patient is injected with a tumor localizing drug containing a non-radioactive isotope (Boron-10) with high slow neutron capture cross-section. In a second step, the patient is irradiated with neutrons, which are absorbed by the Boron-10 agent with the subsequently nuclear reaction B- 10(n,a)Li-7, thereby resulting in dose at cellular level due to the high-Let particles. The neutron fields suitable for BNCT are characterized by high neutron fluxes and low gamma dose. Determination of each component is not an easy task, especially when the volume of measurement is quite small or inaccessible for a miniature ionization chamber, for example. A method of measuring the photon and slow neutron dose(mainly by N-14 and B-10) from the glow curve (GC) analysis of a single {sup 7}LiF thermoluminescence detector is evaluated. This method was suggested by the group headed by Dr. Grazia Gambarini. The dosemeters used were TLD-600 ({sup 6}LiF:Mg,Ti with 95.6% {sup 6}Li) and TLD-700 ({sup 7}LiF:Mg,Ti with 99.9% {sup 7}LiF) from Harshaw. Photon dose measurement using the GC analysis method with TLD-700 in mixed fields requires the relation of the two main peaks of a TLD-600 GC shape obtained from an exposition to the same neutron field, and a photon calibrated GC with TLD-700. The requirements for slow neutron dose measurements are similar. In order to properly apply the GC analysis method at the Ra-6 Research Reactor BNCT facility, measurements were carried out in a standard water phantom, fully characterized on the BNCT beam by conventional techniques (activation detectors and paired ionization chambers technique). Next, the method was implemented in whole body dose monitoring of a patient undergoing a BNCT treatment, using a Bo MAb (Bottle Manikin Absorption) phantom

  4. Biodistribution and subcellular localization of an unnatural boron-containing amino acid (cis-ABCPC by imaging secondary ion mass spectrometry for neutron capture therapy of melanomas and gliomas.

    Directory of Open Access Journals (Sweden)

    Subhash Chandra

    Full Text Available The development of new boron-delivery agents is a high priority for improving the effectiveness of boron neutron capture therapy. In the present study, 1-amino-3-borono-cyclopentanecarboxylic acid (cis-ABCPC as a mixture of its L- and D-enantiomers was evaluated in vivo using the B16 melanoma model for the human tumor and the F98 rat glioma as a model for human gliomas. A secondary ion mass spectrometry (SIMS based imaging instrument, CAMECA IMS 3F SIMS Ion Microscope, was used for quantitative imaging of boron at 500 nm spatial resolution. Both in vivo and in vitro studies in melanoma models demonstrated that boron was localized in the cytoplasm and nuclei with some cell-to-cell variability. Uptake of cis-ABCPC in B16 cells was time dependent with a 7.5:1 partitioning ratio of boron between cell nuclei and the nutrient medium after 4 hrs. incubation. Furthermore, cis-ABCPC delivered boron to cells in all phases of the cell cycle, including S-phase. In vivo SIMS studies using the F98 rat glioma model revealed an 8:1 boron partitioning ratio between the main tumor mass and normal brain tissue with a 5:1 ratio between infiltrating tumor cells and contiguous normal brain. Since cis-ABCPC is water soluble and can cross the blood-brain-barrier via the L-type amino acid transporters (LAT, it may accumulate preferentially in infiltrating tumor cells in normal brain due to up-regulation of LAT in high grade gliomas. Once trapped inside the tumor cell, cis-ABCPC cannot be metabolized and remains either in a free pool or bound to cell matrix components. The significant improvement in boron uptake by both the main tumor mass and infiltrating tumor cells compared to those reported in animal and clinical studies of p-boronophenylalanine strongly suggest that cis-ABCPC has the potential to become a novel new boron delivery agent for neutron capture therapy of gliomas and melanomas.

  5. Video Screen Capture Basics

    Science.gov (United States)

    Dunbar, Laura

    2014-01-01

    This article is an introduction to video screen capture. Basic information of two software programs, QuickTime for Mac and BlueBerry Flashback Express for PC, are also discussed. Practical applications for video screen capture are given.

  6. Radiative electron capture

    International Nuclear Information System (INIS)

    Some data are presented for radiative electron capture by fast moving ions. The radiative electron capture spectrum is shown for O8+ in Ag, along with the energy dependence of the capture cross-section. A discrepancy between earlier data, theoretical prediction, and the present data is pointed out. (3 figs) (U.S.)

  7. Quantitative evaluation of boron neutron capture therapy (BNCT) drugs for boron delivery and retention at subcellular scale resolution in human glioblastoma cells with imaging secondary ion mass spectrometry (SIMS)

    Science.gov (United States)

    Chandra, S.; Ahmad, T.; Barth, R. F.; Kabalka, G. W.

    2014-01-01

    Boron neutron capture therapy (BNCT) of cancer depends on the selective delivery of a sufficient number of boron-10 (10B) atoms to individual tumor cells. Cell killing results from the 10B (n, α)7Li neutron capture and fission reactions that occur if a sufficient number of 10B atoms are localized in the tumor cells. Intranuclear 10B localization enhances the efficiency of cell killing via damage to the DNA. The net cellular content of 10B atoms reflects both bound and free pools of boron in individual tumor cells. The assessment of these pools, delivered by a boron delivery agent, currently cannot be made at subcellular scale resolution by clinically applicable techniques such as PET and MRI. In this study, secondary ion mass spectrometry (SIMS) based imaging instrument, a CAMECA IMS 3f ion microscope, capable of 500 nm spatial resolution was employed. Cryogenically prepared cultured human T98G glioblastoma cells were evaluated for boron uptake and retention of two delivery agents. The first, L-p-boronophenylalanine (BPA), has been used clinically for BNCT of high grade gliomas, recurrent tumors of the head and neck region and melanomas. The second, a boron analogue of an unnatural amino acid, 1-amino-3-borono-cyclopentanecarboxylic acid (cis-ABCPC), has been studied in rodent glioma and melanoma models by quantification of boron in the nucleus and cytoplasm of individual tumor cells. The bound and free pools of boron were assessed by exposure of cells to boron-free nutrient medium. Both BPA and cis-ABCPC delivered almost 70% of the pool of boron in the free or loosely bound form to the nucleus and cytoplasm of human glioblastoma cells. This free pool of boron could be easily mobilized out of the cell and was in some sort of equilibrium with extracellular boron. In the case of BPA, the intracellular free pool of boron also was affected by the presence of phenylalanine in the nutrient medium. This suggests that it might be advantageous if patients were placed on a

  8. Dosimetry methods in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D. [Universita degli Studi di Milano, Department of Physics, Via Festa del Patrono 7, 20122 Milano (Italy); Agosteo, S.; Barcaglioni, L. [Istituto Nazionale di Fisica Nucleare, Milano (Italy); Campi, F.; Garlati, L. [Politecnico di Milano, Energy Department, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); De Errico, F. [Universita degli Studi di Pisa, Department of Civil and Industrial Engineering, Lungamo Pacinotti 43, 56126 Pisa (Italy); Borroni, M.; Carrara, M. [Fondazione IRCCS Istituto Nazionale Tumori, Medical Physics Unit, Via Venezian 1, 20133 Milano (Italy); Burian, J.; Klupak, V.; Viererbl, L.; Marek, M. [Research Centre Rez, Department of Neutron Physics, 250-68 Husinec-Rez (Czech Republic)

    2014-08-15

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  9. Dosimetry methods in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  10. Preventing knee injuries in adolescent female football players – design of a cluster randomized controlled trial [NCT00894595

    Directory of Open Access Journals (Sweden)

    Waldén Markus

    2009-06-01

    be effective in reducing the incidence of knee injury, it can have a major impact by reducing the future knee injury burden in female football as well as the negative long-term disabilities associated with knee injury. Trial registration NCT00894595

  11. Rationale, design, and protocol for the prevention of low back pain in the military (POLM trial (NCT00373009

    Directory of Open Access Journals (Sweden)

    Dugan Jessica L

    2007-09-01

    . Soldiers will receive a monthly email that queries whether any LBP was experienced in the previous calendar month. Soldiers reporting LBP will enter episode-specific data related to pain intensity, pain-related disability, fear-avoidance beliefs, and pain catastrophizing. We are hypothesizing that Soldiers receiving the CSEP and PSEP will report the longest duration to first episode of LBP, the lowest frequency of LBP, and the lowest severity of LBP episodes. Statistical comparisons will be made between each of the randomly assigned prevention programs to test our hypotheses related to determining which of the 4 programs is most effective. Discussion We have presented the design and protocol for the POLM trial. Completion of this trial will provide important information on how to effectively train Soldiers for the prevention of LBP. Trial registration NCT00373009

  12. Capture Their Attention: Capturing Lessons Using Screen Capture Software

    Science.gov (United States)

    Drumheller, Kristina; Lawler, Gregg

    2011-01-01

    When students miss classes for university activities such as athletic and academic events, they inevitably miss important class material. Students can get notes from their peers or visit professors to find out what they missed, but when students miss new and challenging material these steps are sometimes not enough. Screen capture and recording…

  13. Boron neutron capture therapy (BNCT) for liver metastasis in an experimental model: dose–response at five-week follow-up based on retrospective dose assessment in individual rats

    Energy Technology Data Exchange (ETDEWEB)

    Emiliano C. C. Pozzi; Veronica A. Trivilin; Lucas L. Colombo; Andrea Monti Hughes; Silvia I. Thorp; Jorge E. Cardoso; Marcel A. Garabalino; Ana J. Molinari; Elisa M. Heber; Paula Curotto; Marcelo Miller; Maria E. Itoiz; Romina F. Aromando; David W. Nigg; Amanda E. Schwint

    2013-11-01

    Boron neutron capture therapy (BNCT) was proposed for untreatable colorectal liver metastases. Employing an experimental model of liver metastases in rats, we recently demonstrated that BNCT mediated by boronophenylalanine (BPA-BNCT) at 13 Gy prescribed to tumor is therapeutically useful at 3-week follow-up. The aim of the present study was to evaluate dose–response at 5-week follow-up, based on retrospective dose assessment in individual rats. BDIX rats were inoculated with syngeneic colon cancer cells DHD/K12/TRb. Tumor-bearing animals were divided into three groups: BPA-BNCT (n = 19), Beam only (n = 8) and Sham (n = 7) (matched manipulation, no treatment). For each rat, neutron flux was measured in situ and boron content was measured in a pre-irradiation blood sample for retrospective individual dose assessment. For statistical analysis (ANOVA), individual data for the BPA-BNCT group were pooled according to absorbed tumor dose, BPA-BNCT I: 4.5–8.9 Gy and BPA-BNCT II: 9.2–16 Gy. At 5 weeks post-irradiation, the tumor surface area post-treatment/pre-treatment ratio was 12.2 +/- 6.6 for Sham, 7.8 +/- 4.1 for Beam only, 4.4 +/- 5.6 for BPA-BNCT I and 0.45 +/- 0.20 for BPA-BNCT II; tumor nodule weight was 750 +/- 480 mg for Sham, 960 +/- 620 mg for Beam only, 380 +/- 720 mg for BPA-BNCT I and 7.3 +/- 5.9 mg for BPA-BNCT II. The BPA-BNCT II group exhibited statistically significant tumor control with no contributory liver toxicity. Potential threshold doses for tumor response and significant tumor control were established at 6.1 and 9.2 Gy, respectively.

  14. High-power electron beam tests of a liquid-lithium target and characterization study of (7)Li(p,n) near-threshold neutrons for accelerator-based boron neutron capture therapy.

    Science.gov (United States)

    Halfon, S; Paul, M; Arenshtam, A; Berkovits, D; Cohen, D; Eliyahu, I; Kijel, D; Mardor, I; Silverman, I

    2014-06-01

    A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center (SNRC). The target is intended to demonstrate liquid-lithium target capabilities to constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals. The lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power >5kW generated by high-intensity proton beams, necessary for sufficient therapeutic neutron flux. In preliminary experiments liquid lithium was flown through the target loop and generated a stable jet on the concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power densities of more than 4kW/cm(2) and volumetric power density around 2MW/cm(3) at a lithium flow of ~4m/s, while maintaining stable temperature and vacuum conditions. These power densities correspond to a narrow (σ=~2mm) 1.91MeV, 3mA proton beam. A high-intensity proton beam irradiation (1.91-2.5MeV, 2mA) is being commissioned at the SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator. In order to determine the conditions of LiLiT proton irradiation for BNCT and to tailor the neutron energy spectrum, a characterization of near threshold (~1.91MeV) (7)Li(p,n) neutrons is in progress based on Monte-Carlo (MCNP and Geant4) simulation and on low-intensity experiments with solid LiF targets. In-phantom dosimetry measurements are performed using special designed dosimeters based on CR-39 track detectors. PMID:24387907

  15. Blood-brain barrier (BBB) toxicity and permeability assessment after L-(4-¹⁰Boronophenyl)alanine, a conventional B-containing drug for boron neutron capture therapy, using an in vitro BBB model.

    Science.gov (United States)

    Roda, E; Nion, S; Bernocchi, G; Coccini, T

    2014-10-01

    Since brain tumours are the primary candidates for treatment by Boron Neutron Capture Therapy, one major challenge in the selective drug delivery to CNS is the crossing of the blood-brain barrier (BBB). The present pilot study investigated (i) the transport of a conventional B-containing product (i.e., L-(4-(10)Boronophenyl)alanine, L-(10)BPA), already used in medicine but still not fully characterized regarding its CNS interactions, as well as (ii) the effects of the L-(10)BPA on the BBB integrity using an in vitro model, consisting of brain capillary endothelial cells co-cultured with glial cells, closely mimicking the in vivo conditions. The multi-step experimental strategy (i.e. Integrity test, Filter study, Transport assay) checked L-(10)BPA toxicity at 80 µg Boron equivalent/ml, and its ability to cross the BBB, additionally by characterizing the cytoskeletal and TJ's proteins by immunocytochemistry and immunoblotting. In conclusion, a lack of toxic effects of L-(10)BPA was demonstrated, nevertheless accompanied by cellular stress phenomena (e.g. vimentin expression modification), paralleled by a low permeability coefficient (0.39 ± 0.01 × 10(-3)cm min(-1)), corroborating the scarce probability that L-(10)BPA would reach therapeutically effective cerebral concentration. These findings emphasized the need for novel strategies aimed at optimizing boron delivery to brain tumours, trying to ameliorate the compound uptake or developing new targeted products suitable to safely and effectively treat head cancer. Thus, the use of in vitro BBB model for screening studies may provide a useful early safety assessment for new effective compounds.

  16. High-power electron beam tests of a liquid-lithium target and characterization study of (7)Li(p,n) near-threshold neutrons for accelerator-based boron neutron capture therapy.

    Science.gov (United States)

    Halfon, S; Paul, M; Arenshtam, A; Berkovits, D; Cohen, D; Eliyahu, I; Kijel, D; Mardor, I; Silverman, I

    2014-06-01

    A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center (SNRC). The target is intended to demonstrate liquid-lithium target capabilities to constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals. The lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power >5kW generated by high-intensity proton beams, necessary for sufficient therapeutic neutron flux. In preliminary experiments liquid lithium was flown through the target loop and generated a stable jet on the concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power densities of more than 4kW/cm(2) and volumetric power density around 2MW/cm(3) at a lithium flow of ~4m/s, while maintaining stable temperature and vacuum conditions. These power densities correspond to a narrow (σ=~2mm) 1.91MeV, 3mA proton beam. A high-intensity proton beam irradiation (1.91-2.5MeV, 2mA) is being commissioned at the SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator. In order to determine the conditions of LiLiT proton irradiation for BNCT and to tailor the neutron energy spectrum, a characterization of near threshold (~1.91MeV) (7)Li(p,n) neutrons is in progress based on Monte-Carlo (MCNP and Geant4) simulation and on low-intensity experiments with solid LiF targets. In-phantom dosimetry measurements are performed using special designed dosimeters based on CR-39 track detectors.

  17. Neutron Capture Nucleosynthesis

    OpenAIRE

    Kiss, Miklos

    2016-01-01

    Heavy elements (beyond iron) are formed in neutron capture nucleosynthesis processes. We have proposed a simple unified model to investigate the neutron capture nucleosynthesis in arbitrary neutron density environment. We have also investigated what neutron density is required to reproduce the measured abundance of nuclei assuming equilibrium processes. We found both of these that the medium neutron density has a particularly important role at neutron capture nucleosynthesis. About these resu...

  18. Neutron Capture Nucleosynthesis

    CERN Document Server

    Kiss, Miklos

    2016-01-01

    Heavy elements (beyond iron) are formed in neutron capture nucleosynthesis processes. We have proposed a simple unified model to investigate the neutron capture nucleosynthesis in arbitrary neutron density environment. We have also investigated what neutron density is required to reproduce the measured abundance of nuclei assuming equilibrium processes. We found both of these that the medium neutron density has a particularly important role at neutron capture nucleosynthesis. About these results most of the nuclei can formed at medium neutron capture density environment e.g. in some kind of AGB stars. Besides these observations our model is capable to use educational purpose.

  19. Capture ready study

    Energy Technology Data Exchange (ETDEWEB)

    Minchener, A.

    2007-07-15

    There are a large number of ways in which the capture of carbon as carbon dioxide (CO{sub 2}) can be integrated into fossil fuel power stations, most being applicable for both gas and coal feedstocks. To add to the choice of technology is the question of whether an existing plant should be retrofitted for capture, or whether it is more attractive to build totally new. This miscellany of choices adds considerably to the commercial risk of investing in a large power station. An intermediate stage between the non-capture and full capture state would be advantageous in helping to determine the best way forward and hence reduce those risks. In recent years the term 'carbon capture ready' or 'capture ready' has been coined to describe such an intermediate stage plant and is now widely used. However a detailed and all-encompassing definition of this term has never been published. All fossil fuel consuming plant produce a carbon dioxide gas byproduct. There is a possibility of scrubbing it with an appropriate CO{sub 2} solvent. Hence it could be said that all fossil fuel plant is in a condition for removal of its CO{sub 2} effluent and therefore already in a 'capture ready' state. Evidently, the practical reality of solvent scrubbing could cost more than the rewards offered by such as the ETS (European Trading Scheme). In which case, it can be said that although the possibility exists of capturing CO{sub 2}, it is not a commercially viable option and therefore the plant could not be described as ready for CO{sub 2} capture. The boundary between a capture ready and a non-capture ready condition using this definition cannot be determined in an objective and therefore universally acceptable way and criteria must be found which are less onerous and less potentially contentious to assess. 16 refs., 2 annexes.

  20. 用于硼中子俘获治疗的超热中子束理论设计%Theoretical design of an epithermal neutron beam for boron neutron capture therapy

    Institute of Scientific and Technical Information of China (English)

    张晓敏; 潘洁; 宁静; 谢向东; 杨国山

    2010-01-01

    Objective To design a scheme of epithermal neutron beam used for boron neutron capture therapy (BNCT).Methods Based on Tsinghua University experimental reactor and its No.1 passage,five schemes comprised of moderate materials,absorbing materials of thermal neutron and γ shielding materials were designed according to different locations of materials placed in No.1 passage.To select a proper scheme from five schemes,the neutron fluence rate,the neutron dose rate and γ dose rate at exit of beam in each scheme were calculated with Monte Carlo simulating methods and then contrasted with BNCT technique criterion.Results The scheme of epithermal neutron beam meeting technical requirements of BNCT was obtained,in which the thickness of moderate material,absorbing materials of thermal neutron and γ shielding materials are 53.5 cm,2 mm and 9 cm,respectively.Conclusions The theoretical scheme could provide some reference to realize BNCT on reactor.%目的 设计用于硼中子俘获治疗(BNCT)的超热中子束理论方案.方法 基于清华大学试验核反应堆,以其1号孔道为材料布放孔道,设计了由慢化材料、热中子吸收材料、γ屏蔽材料组成,但材料布放位置具有差异的5种理论方案;利用蒙特卡罗(MC)模拟方法,分别计算5种方案束出口处的中子注量率、剂量率及γ剂量率值,通过与BNCT技术指标对比,从5种方案中选择一种合适的方案.结果 得到了一个符合BNCT各项技术指标的超热中子束理论方案,其慢化材料厚度为53.5 cm、热中子吸收材料厚度为2 mm、γ屏蔽材料厚度为9 cm.结论 本研究给出的超热中子束理论方案为基于反应堆实现BNCT提供一定的理论参考.

  1. CAPTURED Ghana Country Evaluation

    NARCIS (Netherlands)

    Sefa Dei, G.J.; Brouwers, J.H.A.M.

    2012-01-01

    This report provides the findings of the Ghana Country Evaluation and is produced as part of the overall CAPTURED End Evaluation. After five years of support by the CAPTURED project the University of Development Studies has been able to achieve commendable results. It can be confirmed that the conte

  2. CAPTURED India Country Evaluation

    NARCIS (Netherlands)

    O'Donoghue, R.; Brouwers, J.H.A.M.

    2012-01-01

    This report provides the findings of the India Country Evaluation and is produced as part of the overall CAPTURED End Evaluation. After five years of support by the CAPTURED project the End Evaluation has assessed that results are commendable. I-AIM was able to design an approach in which health fol

  3. Carbon Capture and Storage

    NARCIS (Netherlands)

    Benson, S.M.; Bennaceur, K.; Cook, P.; Davison, J.; Coninck, H. de; Farhat, K.; Ramirez, C.A.; Simbeck, D.; Surles, T.; Verma, P.; Wright, I.

    2012-01-01

    Emissions of carbon dioxide, the most important long-lived anthropogenic greenhouse gas, can be reduced by Carbon Capture and Storage (CCS). CCS involves the integration of four elements: CO 2 capture, compression of the CO2 from a gas to a liquid or a denser gas, transportation of pressurized CO 2

  4. Direct thermal neutron capture

    International Nuclear Information System (INIS)

    We discuss the direct-capture theory pertaining to primary electric dipole (E1) transitions following slow-neutron capture. For light nuclides that we have studied (including 9Be, 12C, 13C, 24Mg, 25Mg, 26Mg, 32S, 33S, 34S, 40Ca, and 44Ca), estimates of direct-capture cross sections using optical-model potentials with physically realistic parameters, are in reasonable agreement with the data. Minor disagreements that exist are consistent with extrapolations to light nuclides of generally accepted formulations of compound-nucleus capture. We also discuss the channel-capture approximation which is, in general, a good representation of these cross sections in heavier nuclei particularly if the scattering lengths are not different from the corresponding potential radii. We also draw attention to cases where the use of this formula leads to inaccurate predictions. 9 refs., 1 fig., 2 tab

  5. Feasibility evaluation of neutron capture therapy for hepatocellular carcinoma using selective enhancement of boron accumulation in tumour with intra-arterial administration of boron-entrapped water-in-oil-in-water emulsion

    International Nuclear Information System (INIS)

    Introduction: Hepatocellular carcinoma (HCC) is one of the most difficult to cure with surgery, chemotherapy, or other combinational therapies. In the treatment of HCC, only 30% patients can be operated due to complication of liver cirrhosis or multiple intrahepatic tumours. Tumour cell destruction in boron neutron-capture therapy (BNCT) is due to the nuclear reaction between 10B atoms and thermal neutrons, so it is necessary to accumulate a sufficient quantity of 10B atoms in tumour cells for effective tumour cell destruction by BNCT. Water-in-oil-in-water (WOW) emulsion has been used as the carrier of anti-cancer agents on intra-arterial injections in clinical. In this study, we prepared 10BSH entrapped WOW emulsion by double emulsifying technique using iodized poppy-seed oil (IPSO), 10BSH and surfactant, for selective intra-arterial infusion to HCC, and performed simulations of the irradiation in order to calculate the dose delivered to the patients. Materials and methods: WOW emulsion was administrated with intra-arterial injections via proper hepatic artery on VX-2 rabbit hepatic tumour models. We simulated the irradiation of epithermal neutron and calculated the dose delivered to the tissues with JAEA computational dosimetry system (JCDS) at JRR4 reactor of Japan Atomic Research Institute, using the CT scans of a HCC patient. Results and discussions: The 10B concentrations in VX-2 tumour obtained by delivery with WOW emulsion were superior to those by conventional IPSO mix emulsion. According to the rabbit model, the boron concentrations (ppm) in tumour, normal liver tissue, and blood are 61.7, 4.3, and 0.1, respectively. The results of the simulations show that normal liver biologically weighted dose is restricted to 4.9 Gy-Eq (CBE; liver tumour: 2.5, normal liver: 0.94); the maximum, minimum, and mean tumour weighted dose are 43.1, 7.3, and 21.8 Gy-Eq, respectively, in 40 min irradiation. In this study, we show that 10B entrapped WOW emulsion could be

  6. Feasibility evaluation of neutron capture therapy for hepatocellular carcinoma using selective enhancement of boron accumulation in tumour with intra-arterial administration of boron-entrapped water-in-oil-in-water emulsion

    Energy Technology Data Exchange (ETDEWEB)

    Yanagie, Hironobu, E-mail: yanagie@n.t.u-tokyo.ac.jp [Dept of Nuclear Engineering and Management, Graduate School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)] [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan); Kumada, Hiroaki [Proton Medical Research Center, University of Tsukuba, Ibaraki (Japan); Nakamura, Takemi [Japan Atomic Energy Research Institute, Ibaraki (Japan); Higashi, Syushi [Dept of Surgery, Ebihara Memorial Hospital, Miyazaki (Japan)] [Kyushu Industrial Sources Foundation, Miyazaki (Japan); Ikushima, Ichiro [Dept of Radiology, Miyakonojyo Metropolitan Hospital, Miyazaki (Japan); Morishita, Yasuyuki [Dept of Human and Molecular Pathology, Graduate School of Medicine, University of Tokyo, Tokyo (Japan); Shinohara, Atsuko [Dept of Humanities, Graduate School of Seisen University, Tokyo (Japan); Fijihara, Mitsuteru [SPG Techno Ltd. Co., Miyazaki (Japan); Suzuki, Minoru; Sakurai, Yoshinori [Research Reactor Institute, Kyoto University, Osaka (Japan); Sugiyama, Hirotaka [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan); Kajiyama, Tetsuya [Kyushu Industrial Sources Foundation, Miyazaki (Japan); Nishimura, Ryohei [Dept of Veternary Surgery, University of Tokyo Veternary Hospital, Tokyo (Japan); Ono, Koji [Research Reactor Institute, Kyoto University, Osaka (Japan); Nakajima, Jun; Ono, Minoru [Dept of Cardiothracic Surgery, University of Tokyo Hospital, Tokyo (Japan); Eriguchi, Masazumi [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan)] [Department of Surgery, Shin-Yamanote Hospital, Saitama (Japan); Takahashi, Hiroyuki [Dept of Nuclear Engineering and Management, Graduate School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)] [Cooperative Unit of Medicine and Engineering, University of Tokyo Hospital, Tokyo (Japan)

    2011-12-15

    Introduction: Hepatocellular carcinoma (HCC) is one of the most difficult to cure with surgery, chemotherapy, or other combinational therapies. In the treatment of HCC, only 30% patients can be operated due to complication of liver cirrhosis or multiple intrahepatic tumours. Tumour cell destruction in boron neutron-capture therapy (BNCT) is due to the nuclear reaction between {sup 10}B atoms and thermal neutrons, so it is necessary to accumulate a sufficient quantity of {sup 10}B atoms in tumour cells for effective tumour cell destruction by BNCT. Water-in-oil-in-water (WOW) emulsion has been used as the carrier of anti-cancer agents on intra-arterial injections in clinical. In this study, we prepared {sup 10}BSH entrapped WOW emulsion by double emulsifying technique using iodized poppy-seed oil (IPSO), {sup 10}BSH and surfactant, for selective intra-arterial infusion to HCC, and performed simulations of the irradiation in order to calculate the dose delivered to the patients. Materials and methods: WOW emulsion was administrated with intra-arterial injections via proper hepatic artery on VX-2 rabbit hepatic tumour models. We simulated the irradiation of epithermal neutron and calculated the dose delivered to the tissues with JAEA computational dosimetry system (JCDS) at JRR4 reactor of Japan Atomic Research Institute, using the CT scans of a HCC patient. Results and discussions: The {sup 10}B concentrations in VX-2 tumour obtained by delivery with WOW emulsion were superior to those by conventional IPSO mix emulsion. According to the rabbit model, the boron concentrations (ppm) in tumour, normal liver tissue, and blood are 61.7, 4.3, and 0.1, respectively. The results of the simulations show that normal liver biologically weighted dose is restricted to 4.9 Gy-Eq (CBE; liver tumour: 2.5, normal liver: 0.94); the maximum, minimum, and mean tumour weighted dose are 43.1, 7.3, and 21.8 Gy-Eq, respectively, in 40 min irradiation. In this study, we show that {sup 10}B

  7. Marine turtle capture data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — To estimate abundance, growth, and survival rate and to collect tissue samples, marine turtles are captured at nesting beaches and foraging grounds through various...

  8. Neutrinoless double electron capture

    CERN Document Server

    Kotila, J; Iachello, F

    2015-01-01

    Direct determination of the neutrino mass is at the present time one of the most important aims of experimental and theoretical research in nuclear and particle physics. A possible way of detection is through neutrinoless double electron capture, $0\

  9. SIMS ion microscopy imaging of boronophenylalanine (BPA) and 13C15N-labeled phenylalanine in human glioblastoma cells: Relevance of subcellular scale observations to BPA-mediated boron neutron capture therapy of cancer

    Science.gov (United States)

    Chandra, Subhash; Lorey, Daniel R., II

    2007-02-01

    p-Boronophenylalanine (BPA) is a clinically approved boron neutron capture therapy (BNCT) agent currently being used in clinical trials of glioblastoma multiforme, melanoma and liver metastases. Secondary ion mass spectrometry (SIMS) observations from the Cornell SIMS Laboratory provided support for using a 6 h infusion of BPA, instead of a 2 h infusion, for achieving higher levels of boron in brain tumor cells. These observations were clinically implemented in Phase II experimental trials of glioblastoma multiforme in Sweden. However, the mechanisms for higher BPA accumulation with longer infusions have remained unknown. In this work, by using 13C15N-labeled phenylalanine and T98G human glioblastoma cells, comparisons between the 10B-delivery of BPA and the accumulation of labeled phenylalanine after 2 and 6 h treatments were made with a Cameca IMS-3f SIMS ion microscope at 500 nm spatial resolution in fast frozen, freeze-fractured, freeze-dried cells. Due to the presence of the Na-K-ATPase in the plasma membrane of most mammalian cells, the cells maintain an approximately 10/1 ratio of K/Na in the intracellular milieu. Therefore, the quantitative imaging of these highly diffusible species in the identical cell in which the boron or labeled amino acid was imaged provides a rule-of-thumb criterion for validation of SIMS observations and the reliability of the cryogenic sampling. The labeled phenylalanine was detected at mass 28, as the 28(13C15N)- molecular ion. Correlative analysis with optical and confocal laser scanning microscopy revealed that fractured freeze-dried glioblastoma cells contained well-preserved ultrastructural details with three discernible subcellular regions: a nucleus or multiple nuclei, a mitochondria-rich perinuclear cytoplasmic region and the remaining cytoplasm. SIMS analysis revealed that the overall cellular signals of both 10B from BPA and 28CN- from labeled phenylalanine increased approximately 1.6-fold between the 2 and 6 h exposures

  10. Tratamiento del cáncer por captura neutrónica de boro: Su aplicación al carcinoma indiferenciado de tiroides Boron neutron capture therapy applied to undifferentiated thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Mario A. Pisarev

    2006-12-01

    Full Text Available El cáncer indiferenciado de tiroides es un tumor muy agresivo, de muy mal pronóstico y sin tratamiento efectivo. La terapia por captura neutrónica de boro (BNCT podría ser una alternativa para el tratamiento de esta enfermedad. Se basa en la captación selectiva de boro por el tumor y su activación por un haz de neutrones. El boro activado libera un núcleo de litio-7 y una partícula alfa, las cuales tienen una alta transmisión linear de energía (linear energy transfer, LET y un alcance de 5-9 µm, destruyendo el tumor. En estudios previos hemos mostrado que la línea celular humana de cáncer indiferenciado de tiroides (ARO tiene una captación selectiva de borofenilalanina (10BPA tanto in vitro como después de ser implantada en ratones NIH nude. También demostramos en estos animales inyectados con BPA e irradiados con un haz de neutrones térmicos, un 100% de control sobre el crecimiento tumoral y un 50% de cura histológica. En trabajos posteriores mostramos que la porfirina 10BOPP tetrakis-carborane carboxylate ester de 2,4-bis-(a,b-dihydroxyethyl-deutero-porphyrin IX cuando es inyectada 5-7 días antes que el BPA se obtiene una concentración tumoral de boro de aproximadamente el doble que el BPA solo (45-38 ppm vs. 20 ppm. La posterior irradiación con neutrones mostró un 100% de remisión completa en animales con tumores cuyo volumen pre-tratamiento era de 50 mm³ o menor. Los perros padecen CIT espontáneo, con un comportamiento biológico similar al humano, y una captación selectiva de BPA, abriendo la posibilidad de su tratamiento por BNCT.Undifferentiated thyroid carcinoma (UTC is an aggressive tumor with a poor prognosis due to the lack of an effective treatment. Boron neutron capture therapy (BNCT is based on the selective uptake of boron by the tumor and its activation by a neutron beam, releasing lithium-7 and an alpha particle that will kill the tumor cells by their high linear energy transfer (LET. In previous

  11. US Spacesuit Knowledge Capture

    Science.gov (United States)

    Chullen, Cinda; Thomas, Ken; McMann, Joe; Dolan, Kristi; Bitterly, Rose; Lewis, Cathleen

    2011-01-01

    The ability to learn from both the mistakes and successes of the past is vital to assuring success in the future. Due to the close physical interaction between spacesuit systems and human beings as users, spacesuit technology and usage lends itself rather uniquely to the benefits realized from the skillful organization of historical information; its dissemination; the collection and identification of artifacts; and the education of those in the field. The National Aeronautics and Space Administration (NASA), other organizations and individuals have been performing United States (U.S.) Spacesuit Knowledge Capture since the beginning of space exploration. Avenues used to capture the knowledge have included publication of reports; conference presentations; specialized seminars; and classes usually given by veterans in the field. More recently the effort has been more concentrated and formalized whereby a new avenue of spacesuit knowledge capture has been added to the archives in which videotaping occurs engaging both current and retired specialists in the field presenting technical scope specifically for education and preservation of knowledge. With video archiving, all these avenues of learning can now be brought to life with the real experts presenting their wealth of knowledge on screen for future learners to enjoy. Scope and topics of U.S. spacesuit knowledge capture have included lessons learned in spacesuit technology, experience from the Gemini, Apollo, Skylab and Shuttle programs, hardware certification, design, development and other program components, spacesuit evolution and experience, failure analysis and resolution, and aspects of program management. Concurrently, U.S. spacesuit knowledge capture activities have progressed to a level where NASA, the National Air and Space Museum (NASM), Hamilton Sundstrand (HS) and the spacesuit community are now working together to provide a comprehensive closed-looped spacesuit knowledge capture system which includes

  12. Proton capture resonance studies

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, G.E. [North Carolina State University, Raleigh, North Carolina (United States) 27695]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Bilpuch, E.G. [Duke University, Durham, North Carolina (United States) 27708]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Bybee, C.R. [North Carolina State University, Raleigh, North Carolina (United States) 27695]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Cox, J.M.; Fittje, L.M. [Tennessee Technological University, Cookeville, Tennessee (United States) 38505]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Labonte, M.A.; Moore, E.F.; Shriner, J.D. [North Carolina State University, Raleigh, North Carolina (United States) 27695]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Shriner, J.F. Jr. [Tennessee Technological University, Cookeville, Tennessee (United States) 38505]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Vavrina, G.A. [North Carolina State University, Raleigh, North Carolina (United States) 27695]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708; Wallace, P.M. [Duke University, Durham, North Carolina (United States) 27708]|[Triangle Universities Nuclear Laboratory, Durham, North Carolina (United States) 27708

    1997-02-01

    The fluctuation properties of quantum systems now are used as a signature of quantum chaos. The analyses require data of extremely high quality. The {sup 29}Si(p,{gamma}) reaction is being used to establish a complete level scheme of {sup 30}P to study chaos and isospin breaking in this nuclide. Determination of the angular momentum J, the parity {pi}, and the isospin T from resonance capture data is considered. Special emphasis is placed on the capture angular distributions and on a geometric description of these angular distributions. {copyright} {ital 1997 American Institute of Physics.}

  13. CAPTURED End Evaluation Synthesis Report

    NARCIS (Netherlands)

    Brouwers, J.H.A.M.

    2012-01-01

    This report provides the findings of the Synthesis Study of the CAPTURED Evaluation and is produced as part of the overall CAPTURED End Evaluation. After five years of support by the CAPTURED project the three CAPTURED partners have achieved commendable results. Ten lessons learned are formulated th

  14. Study on structures of new types of CTXψ and nct - CTXψ genomes%霍乱弧菌新类型溶源性噬菌体基因组结构研究

    Institute of Scientific and Technical Information of China (English)

    芮勇宇; 阚飙; 高守一; 刘延清; 祁国明

    2007-01-01

    目的 研究霍乱弧菌埃尔托型(EVC)新类型溶源性噬菌体(CTXψ)和核心区不含ctxAB基因的溶源性噬菌体(nct-CTXψ)基因组的结构.方法 采用基因扩增、测序及序列生物信息学等方法进行观察与分析.结果 在我国EVC中,存在仅携带古典型(class)nct-CTXψ、CTXψ或埃尔托型(ET)CTXψ基因组类型,并发现nct-CTXclassψ和CTXETψ共存、nct-CTXnewETψ和CTXclassψ共存的新类型.CTXψ和nct-CTXψ基因组zot基因3'末端,60bp序列中40%位点不同,推测的氨基酸序列中60%位点不同.class、ET和newET类型ig1、rstR和ig2基因序列同源性分别为77.0%~97.4%,10.4%~17.9%,9.6%~64.8%,RstR同源性9.2%~24.1%.CTXψ基因组均位于染色体TLC基因簇附近.上述不同类型EVC的tcpA、TcpA、ctxA、ctxB、CtxA和CtxB与GenBank中EVC和0139群产毒株的同源性分别>99%,99%,99%,98%,98%和96%.结论 首次在EVC中发现nct-CTXclassψ和CTXETψ、nct-CTXnewETψ和CTXclassψ共存的新类型.

  15. Laser capture microscopy

    OpenAIRE

    Curran, S.; McKay, J A; McLeod, H L; Murray, G I

    2000-01-01

    Human tissues are composed of complex admixtures of different cell types and their biologically meaningful analysis necessitates the procurement of pure samples of the cells of interest. Many approaches have been used in attempts to overcome this difficulty, including a variety of microdissection methods. This review concerns a recent advance in microdissection techniques, namely laser capture microdissection (LCM). The principle underlying this technique is outlined, and practical issues per...

  16. Supernova electron capture rates

    CERN Document Server

    Martínez-Pinedo, G

    1999-01-01

    We have calculated the Gamow-Teller strength distributions for the ground states and low lying states of several nuclei that play an important role in the precollapse evolution of supernova. The calculations reproduce the experimental GT distributions nicely. The GT distribution are used to calculate electron capture rates for typical presupernova conditions. The computed rates are noticeably smaller than the presently adopted rates. The possible implications for the supernova evolution are discussed.

  17. NCT 409 Course Tutorial / Snaptutorial

    OpenAIRE

    Antonie

    2015-01-01

    For more classes visit www.snaptutorial.com   NTC 409 Week 1 Individual Switches Routers and Gateways   NTC 409 Week 1 DQ 1   NTC 409 Week 1 DQ 2   NTC 409 Week 2 DQ 1   NTC 409 Week 2 DQ 2   NTC 409 Week 2 Individual Forecasting and Monitoring Tools Paper   NTC 409 Week 2 Learning Team Riordan Manufacturing WAN Project Part I   NTC 409 Week 3 DQ 1   NTC 409 Week 3 DQ 2 ...

  18. NCT 406 Course Tutorial / Snaptutorial

    OpenAIRE

    Antonie

    2015-01-01

    For more classes visit www.snaptutorial.com   NTC 406 Week 1 Individual Assignment Network Requirements Analysis Paper NTC 406 Week 1 Learning Team Assignment  Broadband Over High-Powered Electrical Cables Paper NTC 406 Week 1 Supporting Activity 1 The Layers of the TCP/IP Model NTC 406 Week 1 Supporting Activity Remote File Operations NTC 406 Week 1 DQ 1 NTC 406 Week 1 DQ 2 NTC 406 Week 1 DQ 3 NTC 406 Week 2 Individual Assignment Slow Network...

  19. Lunar Sulfur Capture System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Sulfur Capture System (LSCS) is an innovative method to capture greater than 90 percent of sulfur gases evolved during thermal treatment of lunar soils....

  20. Asfotase alfa therapy for children with hypophosphatasia

    Science.gov (United States)

    Madson, Katherine L.; Phillips, Dawn; Reeves, Amy L.; McAlister, William H.; Yakimoski, Amy; Mack, Karen E.; Hamilton, Kim; Kagan, Kori; Fujita, Kenji P.; Thompson, David D.; Moseley, Scott; Odrljin, Tatjana; Rockman-Greenberg, Cheryl

    2016-01-01

    Background. Hypophosphatasia (HPP) is caused by loss-of-function mutation(s) of the gene that encodes the tissue-nonspecific isoenzyme of alkaline phosphatase (TNSALP). Consequently, cell-surface deficiency of TNSALP phosphohydrolase activity leads to extracellular accumulation of inorganic pyrophosphate, a natural substrate of TNSALP and inhibitor of mineralization. Children with HPP can manifest rickets, skeletal pain, deformity, fracture, muscle weakness, and premature deciduous tooth loss. Asfotase alfa is a recombinant, bone-targeted, human TNSALP injected s.c. to treat HPP. In 2012, we detailed the 1-year efficacy of asfotase alfa therapy for the life-threatening perinatal and infantile forms of HPP. Methods. Here, we evaluated the efficacy and safety of asfotase alfa treatment administered to children 6–12 years of age at baseline who were substantially impaired by HPP. Two radiographic scales quantitated HPP skeletal disease, including comparisons to serial radiographs from similarly affected historical control patients. Results. Twelve children receiving treatment were studied for 5 years. The 6-month primary endpoint was met, showing significant radiographic improvement. Additional significant improvements included patient growth, strength, motor function, agility, and quality of life, which for most patients meant achieving normal values for age- and sex-matched peers that were sustained at 5 years of treatment. For most, pain and disability resolved. Mild to moderate injection-site reactions were common and were sometimes associated with lipohypertrophy. Low anti–asfotase alfa antibody titers were noted in all patients. No evidence emerged for clinically important ectopic calcification or treatment resistance. Conclusions. Asfotase alfa enzyme replacement therapy has substantial and sustained efficacy with a good safety profile for children suffering from HPP. Trial Registration. ClinicalTrials.gov NCT00952484 (https://clinicaltrials.gov/ct2/show/NCT

  1. Capturing lightness between contours.

    Science.gov (United States)

    Vergeer, Mark; van Lier, Rob

    2010-01-01

    Homogeneously coloured bars may exhibit lightness differences at the intersections. A well-known example is the Hermann grid illusion, where crossing white bars on a black background show dark patches at the crossings. Jung (1973, Handbook of Sensory Physiology volume VII/3, pp 1-152) found that the dark patches persist when thin outlines are drawn at the intersections, and are even visible in foveal vision. Recently, it has been shown that making distortions to the contours of a Hermann grid-like configuration results in the disappearance of the illusory dark spots (Geier et al, 2008 Perception 37 651 665). We show that thin outlines at the crossings of the distorted Hermann grid induce lightness differences in the same direction as in the original Hermann grid illusion, even in foveal vision and in displays consisting of two crossing bars. Our experiments reveal that the induced lightness differences are independent of the luminance polarity and shape of the contours at the intersection. We suggest that the effect results from lateral inhibition and an additional spreading and capturing of these differences between luminance contours. A similar capturing between collinear contours may play a role in peripheral vision in the original Hermann grid.

  2. Design and current status of CONTINT: continuous versus interrupted abdominal wall closure after emergency midline laparotomy - a randomized controlled multicenter trial [NCT00544583

    Directory of Open Access Journals (Sweden)

    Rahbari Nuh N

    2012-05-01

    Full Text Available Abstract Background The optimal strategy for abdominal wall closure has been an issue of ongoing debate. Available studies do not specifically enroll patients who undergo emergency laparotomy and thus do not consider the distinct biological characteristics of these patients. The present randomized controlled trial evaluates the efficacy and safety of two commonly applied abdominal wall closure strategies in patients undergoing primary emergency midline laparotomy. Methods/design The CONTINT trial is a multicenter, open label, randomized controlled trial with a two-group parallel design. Patients undergoing a primary emergency midline laparotomy are enrolled in the trial. The two most commonly applied strategies of abdominal wall closure after midline laparotomy are compared: the continuous, all-layer suture technique using slowly absorbable monofilament material (two Monoplus® loops and the interrupted suture technique using rapidly absorbable braided material (Vicryl® sutures. The primary endpoint within the CONTINT trial is an incisional hernia within 12 months or a burst abdomen within 30 days after surgery. As reliable data on this primary endpoint is not available for patients undergoing emergency surgery, an adaptive interim analysis will be conducted after the inclusion of 80 patients, allowing early termination of the trial if necessary or modification of design characteristics such as recalculation of sample size. Discussion This is a randomized controlled multicenter trial with a two-group parallel design to assess the efficacy and safety of two commonly applied abdominal wall closure strategies in patients undergoing primary emergency midline laparotomy. Trial registration NCT00544583

  3. Robust automated knowledge capture.

    Energy Technology Data Exchange (ETDEWEB)

    Stevens-Adams, Susan Marie; Abbott, Robert G.; Forsythe, James Chris; Trumbo, Michael Christopher Stefan; Haass, Michael Joseph; Hendrickson, Stacey M. Langfitt

    2011-10-01

    This report summarizes research conducted through the Sandia National Laboratories Robust Automated Knowledge Capture Laboratory Directed Research and Development project. The objective of this project was to advance scientific understanding of the influence of individual cognitive attributes on decision making. The project has developed a quantitative model known as RumRunner that has proven effective in predicting the propensity of an individual to shift strategies on the basis of task and experience related parameters. Three separate studies are described which have validated the basic RumRunner model. This work provides a basis for better understanding human decision making in high consequent national security applications, and in particular, the individual characteristics that underlie adaptive thinking.

  4. Capturing the Daylight Dividend

    Energy Technology Data Exchange (ETDEWEB)

    Peter Boyce; Claudia Hunter; Owen Howlett

    2006-04-30

    Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.

  5. Particle capture device

    Energy Technology Data Exchange (ETDEWEB)

    Jayne, John T.; Worsnop, Douglas R.

    2016-02-23

    In example embodiments, particle collection efficiency in aerosol analyzers and other particle measuring instruments is improved by a particle capture device that employs multiple collisions to decrease momentum of particles until the particles are collected (e.g., vaporized or come to rest). The particle collection device includes an aperture through which a focused particle beam enters. A collection enclosure is coupled to the aperture and has one or more internal surfaces against which particles of the focused beam collide. One or more features are employed in the collection enclosure to promote particles to collide multiple times within the enclosure, and thereby be vaporized or come to rest, rather than escape through the aperture.

  6. Lunar Sulfur Capture System

    Science.gov (United States)

    Berggren, Mark; Zubrin, Robert; Bostwick-White, Emily

    2013-01-01

    The Lunar Sulfur Capture System (LSCS) protects in situ resource utilization (ISRU) hardware from corrosion, and reduces contaminant levels in water condensed for electrolysis. The LSCS uses a lunar soil sorbent to trap over 98 percent of sulfur gases and about two-thirds of halide gases evolved during hydrogen reduction of lunar soils. LSCS soil sorbent is based on lunar minerals containing iron and calcium compounds that trap sulfur and halide gas contaminants in a fixed-bed reactor held at temperatures between 250 and 400 C, allowing moisture produced during reduction to pass through in vapor phase. Small amounts of Earth-based polishing sorbents consisting of zinc oxide and sodium aluminate are used to reduce contaminant concentrations to one ppm or less. The preferred LSCS configuration employs lunar soil beneficiation to boost concentrations of reactive sorbent minerals. Lunar soils contain sulfur in concentrations of about 0.1 percent, and halogen compounds including chlorine and fluorine in concentrations of about 0.01 percent. These contaminants are released as gases such as H2S, COS, CS2,HCl, and HF during thermal ISRU processing with hydrogen or other reducing gases. Removal of contaminant gases is required during ISRU processing to prevent hardware corrosion, electrolyzer damage, and catalyst poisoning. The use of Earth-supplied, single-use consumables to entirely remove contaminants at the levels existing in lunar soils would make many ISRU processes unattractive due to the large mass of consumables relative to the mass of oxygen produced. The LSCS concept of using a primary sorbent prepared from lunar soil was identified as a method by which the majority of contaminants could be removed from process gas streams, thereby substantially reducing the required mass of Earth-supplied consumables. The LSCS takes advantage of minerals containing iron and calcium compounds that are present in lunar soil to trap sulfur and halide gases in a fixedbed reactor

  7. Photoresponsive Capture and Release of Lectins in Multilamellar Complexes

    NARCIS (Netherlands)

    Samanta, Avik; Stuart, Marc C. A.; Ravoo, Bart Jan

    2012-01-01

    The development of triggered release systems for delivery of peptides and proteins is critical to the success of biological drug therapies. In this paper we describe a dynamic supramolecular system able to capture and release proteins in response to light. The ternary system self-assembles in a dilu

  8. Neutron Capture and Neutron Halos

    OpenAIRE

    A.Mengoni; Otsuka, T; Nakamura, T.(International Center for Elementary Particle Physics and Department of Physics, The University of Tokyo, Tokyo, Japan); Ishihara, M.

    1996-01-01

    The connection between the neutron halo observed in light neutron rich nuclei and the neutron radiative capture process is outlined. We show how nuclear structure information such as spectroscopic factors and external components of the radial wave function of loosely bound states can be derived from the neutron capture cross section. The link between the direct radiative capture and the Coulomb dissociation process is elucidated.

  9. The Generic Data Capture Facility

    Science.gov (United States)

    Connell, Edward B.; Barnes, William P.; Stallings, William H.

    The Generic Data Capture Facility, which can provide data capture support for a variety of different types of spacecraft while enabling operations costs to be carefully controlled, is discussed. The data capture functions, data protection, isolation of users from data acquisition problems, data reconstruction, and quality and accounting are addressed. The TDM and packet data formats utilized by the system are described, and the development of generic facilities is considered.

  10. Inland capture fisheries.

    Science.gov (United States)

    Welcomme, Robin L; Cowx, Ian G; Coates, David; Béné, Christophe; Funge-Smith, Simon; Halls, Ashley; Lorenzen, Kai

    2010-09-27

    The reported annual yield from inland capture fisheries in 2008 was over 10 million tonnes, although real catches are probably considerably higher than this. Inland fisheries are extremely complex, and in many cases poorly understood. The numerous water bodies and small rivers are inhabited by a wide range of species and several types of fisher community with diversified livelihood strategies for whom inland fisheries are extremely important. Many drivers affect the fisheries, including internal fisheries management practices. There are also many drivers from outside the fishery that influence the state and functioning of the environment as well as the social and economic framework within which the fishery is pursued. The drivers affecting the various types of inland water, rivers, lakes, reservoirs and wetlands may differ, particularly with regard to ecosystem function. Many of these depend on land-use practices and demand for water which conflict with the sustainability of the fishery. Climate change is also exacerbating many of these factors. The future of inland fisheries varies between continents. In Asia and Africa the resources are very intensely exploited and there is probably little room for expansion; it is here that resources are most at risk. Inland fisheries are less heavily exploited in South and Central America, and in the North and South temperate zones inland fisheries are mostly oriented to recreation rather than food production.

  11. Resource capture by single leaves

    Energy Technology Data Exchange (ETDEWEB)

    Long, S.P.

    1992-05-01

    Leaves show a variety of strategies for maximizing CO{sub 2} and light capture. These are more meaningfully explained if they are considered in the context of maximizing capture relative to the utilization of water, nutrients and carbohydrates reserves. There is considerable variation between crops in their efficiency of CO{sub 2} and light capture at the leaf level. Understanding of these mechanisms indicate some ways in which efficiency of resource capture could be level cannot be meaningfully considered without simultaneous understanding of implications at the canopy level. 36 refs., 5 figs., 1 tab.

  12. On neutrinoless double electron capture

    CERN Document Server

    Drukarev, E G

    2016-01-01

    We found the probability for the neutrinoless double electron capture in the case of $KK$ capture. We clarified the mechanism of the energy transfer from the nucleus to the bound electrons. This enabled us to obtain the equations for the probability of the $2EC0\

  13. Neutron capture reactions at DANCE

    International Nuclear Information System (INIS)

    The Detector for Advanced Neutron Capture Experiments (DANCE) is a 4π BaF2 array consisting of 160 active detector elements. The primary purpose of the array is to perform neutron capture cross section measurements on small (> or approx.100 μg) and/or radioactive (241,243Am, neutron capture and neutron-induced fission cross sections and capture-to-fission ratio (α = σγ/σf) for 235U using a new fission-tagging detector as well as neutron capture cross sections for several astrophysics branch-point nuclei. Results from several of these measurements will be presented along with a discussion of additional physics information that can be extracted from the DANCE data

  14. Materials For Gas Capture, Methods Of Making Materials For Gas Capture, And Methods Of Capturing Gas

    KAUST Repository

    Polshettiwar, Vivek

    2013-06-20

    In accordance with the purpose(s) of the present disclosure, as embodied and broadly described herein, embodiments of the present disclosure, in one aspect, relate to materials that can be used for gas (e.g., CO.sub.2) capture, methods of making materials, methods of capturing gas (e.g., CO.sub.2), and the like, and the like.

  15. Electron capture and stellar collapse

    International Nuclear Information System (INIS)

    In order, to investigate the function of electron capture in the phenomenon of pre-supernovae gravitacional collapse, an hydrodynamic caculation was carried out, coupling capture, decay and nuclear reaction equation system. A star simplified model (homogeneous model) was adopted using fermi ideal gas approximation for tthe sea of free electrons and neutrons. The non simplified treatment from quasi-static evolution to collapse is presented. The capture and beta decay rates, as wellas neutron delayed emission, were calculated by beta decay crude theory, while the other reaction rates were determined by usual theories. The preliminary results are presented. (M.C.K.)

  16. Gadolinium-neutron capture reactions: A radiobiological assay

    International Nuclear Information System (INIS)

    Gadolinium neutron capture(GNC) takes advantage of its extraordinarily large cross section to thermal neutrons. In GNC reactions, prompt high energy gamma rays, x-rays and electrons are released. Because of the photons and electrons, the intracellular presence of gadolinium is not considered critical. This is an advantage over boron-neutron capture therapy where the intracellular presence of boron is required because of the short flight tracks of 2.4 MeV alpha particles. In this study, the radiation effect of GNC reactions was measured using Chinese hamster cells in an attempt to evaluate the contributions of neutrons, gamma rays and electrons on cell inactivation

  17. Lunar Sulfur Capture System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Sulfur Capture System (LSCS) is an innovative method to recover sulfur compounds from lunar soil using sorbents derived primarily from in-situ resources....

  18. Methane capture from livestock manure.

    Science.gov (United States)

    Tauseef, S M; Premalatha, M; Abbasi, Tasneem; Abbasi, S A

    2013-03-15

    It has been estimated that livestock manure contributes about 240 million metric tons of carbon dioxide equivalent of methane to the atmosphere and represents one of the biggest anthropogenic sources of methane. Considering that methane is the second biggest contributor to global warming after carbon dioxide, it is imperative that ways and means are developed to capture as much of the anthropogenic methane as possible. There is a major associated advantage of methane capture: its use as a source of energy which is comparable in 'cleanness' to natural gas. The present review dwells upon the traditional ways of methane capture used in India, China, and other developing countries for providing energy to the rural poor. It then reviews the present status of methane capture from livestock manure in developed countries and touches upon the prevalent trends.

  19. Value Capture for Transportation Finance

    OpenAIRE

    Zhirong (Jerry) Zhao; Michael Iacono; David Levinson

    2009-01-01

    As vehicles become more fuel-efficient and overall levels of travel stagnate in response to increases in fuel prices, conventional sources of revenue for transportation finance such as taxes on motor fuels have been put under increasing pressure. One potential replacement as a source of revenue is a set of policies collectively referred to as value capture policies. In contrast to fuel taxes and other instruments that impose charges on users of transportation networks, value capture policies ...

  20. Direct Capture at Low Energies

    OpenAIRE

    Balogh, W.; Bieber, R.; Oberhummer, H.; Rauscher, T.; Kratz, K.-L.; Mohr, P; Staudt, G.; Sharma, M. M.

    1994-01-01

    The importance of direct capture for (n,$\\gamma$)--reactions on intermediate-- and heavy--mass target nuclei occuring in the s-- and r--process is investigated. It is shown that the direct mechanism is non--negligible for magic and neutron rich target nuclei. For some double magic and neutron rich nuclei in the r--process direct capture is even the dominant reaction mechanism.

  1. Toward transformational carbon capture systems

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Energy Technology Laboratory, U.S. Dept. of Energy, Pittsburgh PA (United States); Litynski, John T. [Office of Fossil Energy, U.S. Dept. of Energy, Washington DC (United States); Brickett, Lynn A. [National Energy Technology Laboratory, U.S. Dept. of Energy, Pittsburgh PA (United States); Morreale, Bryan D. [National Energy Technology Laboratory, U.S. Dept. of Energy, Pittsburgh PA (United States)

    2015-10-28

    This paper will briefly review the history and current state of Carbon Capture and Storage (CCS) research and development and describe the technical barriers to carbon capture. it will argue forcefully for a new approach to R&D, which leverages both simulation and physical systems at the laboratory and pilot scales to more rapidly move the best technoogies forward, prune less advantageous approaches, and simultaneously develop materials and processes.

  2. Multicenter randomized trial of cell therapy in cardiopathies – MiHeart Study

    Science.gov (United States)

    Tura, Bernardo R; Martino, Helena F; Gowdak, Luis H; dos Santos, Ricardo Ribeiro; Dohmann, Hans F; Krieger, José E; Feitosa, Gilson; Vilas-Boas, Fábio; Oliveira, Sérgio A; Silva, Suzana A; Bozza, Augusto Z; Borojevic, Radovan; de Carvalho, Antonio C Campos

    2007-01-01

    Background Cardiovascular diseases are the major cause of death in the world. Current treatments have not been able to reverse this scenario, creating the need for the development of new therapies. Cell therapies have emerged as an alternative for cardiac diseases of distinct causes in experimental animal studies and more recently in clinical trials. Method/Design We have designed clinical trials to test for the efficacy of autologous bone marrow derived mononuclear cell therapies in four different cardiopathies: acute and chronic ischemic heart disease, and Chagasic and dilated cardiomyopathy. All trials are multicenter, randomized, double-blind and placebo controlled. In each trial 300 patients will be enrolled and receive optimized therapy for their specific condition. Additionally, half of the patients will receive the autologous bone marrow cells while the other half will receive placebo (saline with 5% autologous serum). For each trial there are specific inclusion and exclusion criteria and the method for cell delivery is intramyocardial for the chronic ischemic heart disease and intracoronary for all others. Primary endpoint for all studies will be the difference in ejection fraction (determined by Simpson's rule) six and twelve months after intervention in relation to the basal ejection fraction. The main hypothesis of this study is that the patients who receive the autologous bone-marrow stem cell implant will have after a 6 month follow-up a mean increase of 5% in absolute left ventricular ejection fraction in comparison with the control group. Discussion Many phase I clinical trials using cell therapy for cardiac diseases have already been performed. The few randomized studies have yielded conflicting results, rendering necessary larger well controlled trials to test for efficacy of cell therapies in cardiopathies. The trials registration numbers at the NIH registry are the following: Chagasic cardiomyopathy (NCT00349271), dilated cardiomyopathy (NCT

  3. Multicenter randomized trial of cell therapy in cardiopathies – MiHeart Study

    Directory of Open Access Journals (Sweden)

    Oliveira Sérgio A

    2007-01-01

    Full Text Available Abstract Background Cardiovascular diseases are the major cause of death in the world. Current treatments have not been able to reverse this scenario, creating the need for the development of new therapies. Cell therapies have emerged as an alternative for cardiac diseases of distinct causes in experimental animal studies and more recently in clinical trials. Method/Design We have designed clinical trials to test for the efficacy of autologous bone marrow derived mononuclear cell therapies in four different cardiopathies: acute and chronic ischemic heart disease, and Chagasic and dilated cardiomyopathy. All trials are multicenter, randomized, double-blind and placebo controlled. In each trial 300 patients will be enrolled and receive optimized therapy for their specific condition. Additionally, half of the patients will receive the autologous bone marrow cells while the other half will receive placebo (saline with 5% autologous serum. For each trial there are specific inclusion and exclusion criteria and the method for cell delivery is intramyocardial for the chronic ischemic heart disease and intracoronary for all others. Primary endpoint for all studies will be the difference in ejection fraction (determined by Simpson's rule six and twelve months after intervention in relation to the basal ejection fraction. The main hypothesis of this study is that the patients who receive the autologous bone-marrow stem cell implant will have after a 6 month follow-up a mean increase of 5% in absolute left ventricular ejection fraction in comparison with the control group. Discussion Many phase I clinical trials using cell therapy for cardiac diseases have already been performed. The few randomized studies have yielded conflicting results, rendering necessary larger well controlled trials to test for efficacy of cell therapies in cardiopathies. The trials registration numbers at the NIH registry are the following: Chagasic cardiomyopathy (NCT00349271

  4. CHAOTIC CAPTURE OF NEPTUNE TROJANS

    International Nuclear Information System (INIS)

    Neptune Trojans (NTs) are swarms of outer solar system objects that lead/trail planet Neptune during its revolutions around the Sun. Observations indicate that NTs form a thick cloud of objects with a population perhaps ∼10 times more numerous than that of Jupiter Trojans and orbital inclinations reaching ∼25 deg. The high inclinations of NTs are indicative of capture instead of in situ formation. Here we study a model in which NTs were captured by Neptune during planetary migration when secondary resonances associated with the mean-motion commensurabilities between Uranus and Neptune swept over Neptune's Lagrangian points. This process, known as chaotic capture, is similar to that previously proposed to explain the origin of Jupiter's Trojans. We show that chaotic capture of planetesimals from an ∼35 Earth-mass planetesimal disk can produce a population of NTs that is at least comparable in number to that inferred from current observations. The large orbital inclinations of NTs are a natural outcome of chaotic capture. To obtain the ∼4:1 ratio between high- and low-inclination populations suggested by observations, planetary migration into a dynamically excited planetesimal disk may be required. The required stirring could have been induced by Pluto-sized and larger objects that have formed in the disk.

  5. Nuclear Physics meets Medicine and Biology: Boron Neutron Capture Therapy

    CERN Document Server

    F. Ballarini, F; S. Bortolussi, S; P. Bruschi, P; A.M. Clerici, A M; A. De Bari, A; P. Dionigi, P; C. Ferrari, C; M.A. Gadan, M A; N. Protti, N; S. Stella, S; C. Zonta, C; A. Zonta, A; S. Altieri, S

    2010-01-01

    BNCT is a tumour treatment based on thermal-neutron irradiation of tissues enriched with 10B, which according to the 10B(n, )7Li reaction produces particles with high Linear Energy Transfer and short range. Since this treatment can deliver a therapeutic tumour dose sparing normal tissues, BNCT represents an alternative for diffuse tumours and metastases, which show poor response to surgery and photontherapy. In 2001 and 2003, in Pavia BNCT was applied to an isolated liver, which was infused with boron, explanted, irradiated and re-implanted. A new project was then initiated for lung tumours, developing a protocol for Boron concentration measurements and performing organ-dose Monte Carlo calculations; in parallel, radiobiology studies are ongoing to characterize the BNCT effects down to cellular level. After a brief introduction, herein we will present the main activities ongoing in Pavia including the radiobiological ones, which are under investigation not only experimentally but also theoretically, basing on...

  6. Novel dodecaborate cluster lipids for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Lipids containing the closo-dodecaborate cluster have been developed. Two examples, S-(N,N-(2-dimyristoyloxyethyl) -acetamido)-thioundecahydro-closo-dodecaborate (2-) (B-6-14) and S-(N,N-(2-dipalmitoyloxyethyl) -acetamido)-thioundecahydro-closo-dodecaborate (2-) (B-6-16) have been prepared. With helper lipids, stable liposomes were obtained. (author)

  7. Boron neutron capture therapy: An interdisciplinary co-operation

    International Nuclear Information System (INIS)

    The international (European) undertaking in BNCT in the Netherlands has required close scrutiny of the organisational structure required to establish BNCT facilities. The multidisciplinary co-operation and the tasks of the participants in the hospital (Radiation Oncologist, Medical Physicist, Pharmacist and other medical and paramedical staff) and those attached to the reactor) are described. The organisational structure and regulatory aspects required for the international functioning of the Petten treatment facility are provided for guidance to new projects in this field. (author)

  8. Accelerator Based Neutron Beams for Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yanch, Jacquelyn C.

    2003-04-11

    The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are currently capable of treating patients with rheumatoid arthritis in less than 15 minutes (knee joints) or 4 minutes (finger joints) or irradiating patients with shallow brain tumors to a healthy tissue dose of 12.6 Gy in 3.6 hours. The accelerator, designed by Newton scientific Incorporated, is located in dedicated laboratory space that MIT renovated specifically for this project. The Laboratory for Accelerator Beam Applications consists of an accelerator room, a control room, a shielded radiation vault, and additional laboratory space nearby. In addition to the design, construction and characterization of the tandem electrostatic accelerator, this program also resulted in other significant accomplishments. Assemblies for generating epithermal neutron beams were designed, constructed and experimentally evaluated using mixed-field dosimetry techniques. Strategies for target construction and target cooling were implemented and tested. We demonstrated that the method of submerged jet impingement using water as the coolant is capable of handling power densities of up to 6 x 10(sup 7) W/m(sup 2) with heat transfer coefficients of 10(sup 6)W/m(sup 2)-K. Experiments with the liquid metal gallium demonstrated its superiority compared with water with little effect on the neutronic properties of the epithermal beam. Monoenergetic proton beams generated using the accelerator were used to evaluate proton RBE as a function of LET and demonstrated a maximum RBE at approximately 30-40 keV/um, a finding consistent with results published by other researchers. We also developed an experimental approach to biological intercomparison of epithermal beams and compared the RBE characteristics of the MIT Reactor M67 clinical beam, The Brookhaven Medical Research Reactor clinical beam (both of which were used in Phase I/II clinical trials of BNCT) and the MIT LABA BNCS beam. Additional research initiated under this program involved an investigation of the potential of BNCT for the prevention of restenosis and the development of accelerator-based fast neutron brachytherapy. A total of 10 student research theses (2 Undergraduate, 4 Masters, and 4 Doctoral) were completed as part of this research program.

  9. [A clinical trial of neutron capture therapy for brain tumors

    International Nuclear Information System (INIS)

    This report describes accomplishments by this laboratory concerning development of high-resolution alpha-autoradiography design of an optimized epithermal neutron beam dosimetry and treatment planning Using Monte Carlo techniques development of a prompt-gamma 10B analysis facility

  10. Proton capture by magnetic monopoles

    International Nuclear Information System (INIS)

    In the Kazama-Yang approximation, the lowest monopole-proton bound states have binding energies of 938 MeV, 263 keV, 105 eV, and 0.04 eV. The cross section for radiative capture to these states is for velocities β = 10-5 - 10-3 found to be of the order of 10-28 - 10-26 cm2. For the state that has a binding energy of 263 keV, the capture length in water is 171 x (β/10-4)sup(0.48) m. Observation of photons from the capture process would indicate the presence of monopoles. (orig.)

  11. Earth--Mars Transfers with Ballistic Capture

    OpenAIRE

    Topputo, Francesco; Belbruno, Edward

    2014-01-01

    We construct a new type of transfer from the Earth to Mars, which ends in ballistic capture. This results in a substantial savings in capture $\\Delta v$ from that of a classical Hohmann transfer under certain conditions. This is accomplished by first becoming captured at Mars, very distant from the planet, and then from there, following a ballistic capture transfer to a desired altitude within a ballistic capture set. This is achieved by manipulating the stable sets, or sets of initial condit...

  12. Muon capture on 3H

    CERN Document Server

    Golak, J; Witala, H; Topolnicki, K; Kamada, H; Nogga, A; Marcucci, L E

    2016-01-01

    The muon capture on 3H leading to muonic neutrino and three neutrons in the final state is studied under full inclusion of final state interactions. Predictions for the three-body break-up of 3H are calculated with the AV18 potential, augmented by the Urbana IX three-nucleon force. Our results are based on the single nucleon weak current operator comprising the dominant relativistic corrections. This work is a natural extension of our investigations of the muon capture on 3He leading to 3H or n+d or n+n+p and muonic neutrino in the final state, presented in Phys. Rev. C90, 024001 (2014).

  13. Experimental studies of electron capture

    International Nuclear Information System (INIS)

    This thesis discusses the main results of recent experimental studies of electron capture in asymmetric collisions. Most of the results have been published, but the thesis also contains yet unpublished data, or data presented only in unrefereed conference proceedings. The thesis aims at giving a coherent discussion of the understanding of the experimental results, based first on simple qualitative considerations and subsequently on quantitative comparisons with the best theoretical calculations currently available. (Auth.)

  14. Proton Therapy

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Proton Therapy Proton therapy delivers radiation to tumor tissue ... feel during and after the procedure? What is proton therapy and how is it used? Protons are ...

  15. Oxygen Therapy

    Science.gov (United States)

    Oxygen therapy is a treatment that provides you with extra oxygen. Oxygen is a gas that your body ... machine in your home. A different kind of oxygen therapy is called hyperbaric oxygen therapy. It uses oxygen ...

  16. Financing Capture Ready Coal-Fired Power Plants In China By Issuing Capture Options

    OpenAIRE

    Liang, Xi; Reiner, David; Gibbons, Jon; Jia LI

    2007-01-01

    ?Capture Ready? is a design concept enabling fossil fuel plants to be retrofitted more economically with carbon dioxide capture and storage (CCS) technologies, however financing the cost of capture ready can be problematic, especially in the developing world. We propose that fossil fuel plants issue tradable Capture Options to acquire financing. The Capture Option concept could move CCS forward politically in countries such as China, speed up CCS technology development, help Capture Ready inv...

  17. Realistic costs of carbon capture

    Energy Technology Data Exchange (ETDEWEB)

    Al Juaied, Mohammed (Harvard Univ., Cambridge, MA (US). Belfer Center for Science and International Affiaris); Whitmore, Adam (Hydrogen Energy International Ltd., Weybridge (GB))

    2009-07-01

    There is a growing interest in carbon capture and storage (CCS) as a means of reducing carbon dioxide (CO2) emissions. However there are substantial uncertainties about the costs of CCS. Costs for pre-combustion capture with compression (i.e. excluding costs of transport and storage and any revenue from EOR associated with storage) are examined in this discussion paper for First-of-a-Kind (FOAK) plant and for more mature technologies, or Nth-of-a-Kind plant (NOAK). For FOAK plant using solid fuels the levelised cost of electricity on a 2008 basis is approximately 10 cents/kWh higher with capture than for conventional plants (with a range of 8-12 cents/kWh). Costs of abatement are found typically to be approximately US$150/tCO2 avoided (with a range of US$120-180/tCO2 avoided). For NOAK plants the additional cost of electricity with capture is approximately 2-5 cents/kWh, with costs of the range of US$35-70/tCO2 avoided. Costs of abatement with carbon capture for other fuels and technologies are also estimated for NOAK plants. The costs of abatement are calculated with reference to conventional SCPC plant for both emissions and costs of electricity. Estimates for both FOAK and NOAK are mainly based on cost data from 2008, which was at the end of a period of sustained escalation in the costs of power generation plant and other large capital projects. There are now indications of costs falling from these levels. This may reduce the costs of abatement and costs presented here may be 'peak of the market' estimates. If general cost levels return, for example, to those prevailing in 2005 to 2006 (by which time significant cost escalation had already occurred from previous levels), then costs of capture and compression for FOAK plants are expected to be US$110/tCO2 avoided (with a range of US$90-135/tCO2 avoided). For NOAK plants costs are expected to be US$25-50/tCO2. Based on these considerations a likely representative range of costs of abatement from CCS

  18. Algal Energy Conversion and Capture

    Science.gov (United States)

    Hazendonk, P.

    2015-12-01

    We address the potential for energy conversions and capture for: energy generation; reduction in energy use; reduction in greenhouse gas emissions; remediation of water and air pollution; protection and enhancement of soil fertility. These processes have the potential to sequester carbon at scales that may have global impact. Energy conversion and capture strategies evaluate energy use and production from agriculture, urban areas and industries, and apply existing and emerging technologies to reduce and recapture energy embedded in waste products. The basis of biocrude production from Micro-algal feedstocks: 1) The nutrients from the liquid fraction of waste streams are concentrated and fed into photo bioreactors (essentially large vessels in which microalgae are grown) along with CO2 from flue gasses from down stream processes. 2) The algae are processed to remove high value products such as proteins and beta-carotenes. The advantage of algae feedstocks is the high biomass productivity is 30-50 times that of land based crops and the remaining biomass contains minimal components that are difficult to convert to biocrude. 3) The remaining biomass undergoes hydrothermal liquefaction to produces biocrude and biochar. The flue gasses of this process can be used to produce electricity (fuel cell) and subsequently fed back into the photobioreactor. The thermal energy required for this process is small, hence readily obtained from solar-thermal sources, and furthermore no drying or preprocessing is required keeping the energy overhead extremely small. 4) The biocrude can be upgraded and refined as conventional crude oil, creating a range of liquid fuels. In principle this process can be applied on the farm scale to the municipal scale. Overall, our primary food production is too dependent on fossil fuels. Energy conversion and capture can make food production sustainable.

  19. Enhanced image capture through fusion

    Science.gov (United States)

    Burt, Peter J.; Hanna, Keith; Kolczynski, Raymond J.

    1993-01-01

    Image fusion may be used to combine images from different sensors, such as IR and visible cameras, to obtain a single composite with extended information content. Fusion may also be used to combine multiple images from a given sensor to form a composite image in which information of interest is enhanced. We present a general method for performing image fusion and show that this method is effective for diverse fusion applications. We suggest that fusion may provide a powerful tool for enhanced image capture with broad utility in image processing and computer vision.

  20. Radiative kaon capture in hydrogen

    International Nuclear Information System (INIS)

    Negative kaons were stopped in liquid hydrogen to measure the radiative capture rates to Yγ final states. Branching ratios for the reactions K-p → Λγ and K-p → Σoγ provide information about the quark structure of the Λ(1404). Superior photon resolution is needed to distinguish the signal photons from the background of πo decay photons. Such resolution was provided by a NaI detector, which has a resolution of 1.3% (FWHM) near 300 MeV. A description of the experimental technique and data reduction is presented, along with preliminary branching ratio results

  1. Capturing and storing CO2

    International Nuclear Information System (INIS)

    A promising way to combat global warming is to capture CO2 produced by industry and bury it in deep geologic formations. The processes are technically complex and still expensive. Before it can be captured, CO2 must be separated from other components produced by industrial processes that burn oil, gas, coal or biomass, such as nitrogen and sulfur. The CO2 is then piped down vertically from the storage facility and injected at depths of at least 800 meters. There, it reaches a 'supercritical' state in which it becomes denser and less voluminous. Three types of underground reservoirs have been tested so far: 1 - Deep onshore or offshore saline aquifers: These brackish water-bearing layers constitute the biggest reservoir, with 10,000 billion metric tons of storage capacity. They are also the most evenly distributed geographically, making it easier to find one near the source of emission. 2 - Depleted oil and gas reservoirs: injecting pressurized CO2 helps to dissolve remaining oil and reduce its viscosity. This facilitates the enhanced recovery of oil or gas from nearly depleted reservoirs, adding a potential economic advantage to the operation. The disadvantage of these reservoirs is their distance from CO2-emitting industrial sites. 3 - Unexploited coal seams: the CO2 replaces the methane that is naturally present in the coal bed. The methane can be extracted and marketed by gas companies. There are two additional solutions. The first involves storing the CO2 in carbon 'lakes' in the ocean at a minimum depth of 1,500 meters, but this has been rejected due to concerns about the impacts on the marine ecosystem and how long the CO2 would be contained. The second solution, carbon sequestration by mineral carbonation, is of more interest. Here, CO2 reacts with naturally occurring subsurface calcium and magnesium to become a carbonated rock similar to limestone, which is insoluble and therefore perfectly stable over the long term. The entire CO2 capture, compression

  2. The Effectiveness of Classroom Capture Technology

    Science.gov (United States)

    Ford, Maire B.; Burns, Colleen E.; Mitch, Nathan; Gomez, Melissa M.

    2012-01-01

    The use of classroom capture systems (systems that capture audio and video footage of a lecture and attempt to replicate a classroom experience) is becoming increasingly popular at the university level. However, research on the effectiveness of classroom capture systems in the university classroom has been limited due to the recent development and…

  3. Adaptive capture of expert knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, C.L.; Jones, R.D. [Los Alamos National Lab., NM (United States); Hand, Un Kyong [Los Alamos National Lab., NM (United States)]|[US Navy (United States)

    1995-05-01

    A method is introduced that can directly acquire knowledge-engineered, rule-based logic in an adaptive network. This adaptive representation of the rule system can then replace the rule system in simulated intelligent agents and thereby permit further performance-based adaptation of the rule system. The approach described provides both weight-fitting network adaptation and potentially powerful rule mutation and selection mechanisms. Nonlinear terms are generated implicitly in the mutation process through the emergent interaction of multiple linear terms. By this method it is possible to acquire nonlinear relations that exist in the training data without addition of hidden layers or imposition of explicit nonlinear terms in the network. We smoothed and captured a set of expert rules with an adaptive network. The motivation for this was to (1) realize a speed advantage over traditional rule-based simulations; (2) have variability in the intelligent objects not possible by rule-based systems but provided by adaptive systems: and (3) maintain the understandability of rule-based simulations. A set of binary rules was smoothed and converted into a simple set of arithmetic statements, where continuous, non-binary rules are permitted. A neural network, called the expert network, was developed to capture this rule set, which it was able to do with zero error. The expert network is also capable of learning a nonmonotonic term without a hidden layer. The trained network in feedforward operation is fast running, compact, and traceable to the rule base.

  4. Capture of Irregular Satellites at Jupiter

    CERN Document Server

    Nesvorny, D; Deienno, R

    2014-01-01

    The irregular satellites of outer planets are thought to have been captured from heliocentric orbits. The exact nature of the capture process, however, remains uncertain. We examine the possibility that irregular satellites were captured from the planetesimal disk during the early Solar System instability when encounters between the outer planets occurred (Nesvorny, Vokrouhlicky & Morbidelli 2007, AJ 133; hereafter NVM07). NVM07 already showed that the irregular satellites of Saturn, Uranus and Neptune were plausibly captured during planetary encounters. Here we find that the current instability models present favorable conditions for capture of irregular satellites at Jupiter as well, mainly because Jupiter undergoes a phase of close encounters with an ice giant. We show that the orbital distribution of bodies captured during planetary encounters provides a good match to the observed distribution of irregular satellites at Jupiter. The capture efficiency for each particle in the original transplanetary d...

  5. Immobilized surfactant-nanotube complexes support selectin-mediated capture of viable circulating tumor cells in the absence of capture antibodies.

    Science.gov (United States)

    Mitchell, Michael J; Castellanos, Carlos A; King, Michael R

    2015-10-01

    The metastatic spread of tumor cells from the primary site to anatomically distant organs leads to a poor patient prognosis. Increasing evidence has linked adhesive interactions between circulating tumor cells (CTCs) and endothelial cells to metastatic dissemination. Microscale biomimetic flow devices hold promise as a diagnostic tool to isolate CTCs and develop metastatic therapies, utilizing E-selectin (ES) to trigger the initial rolling adhesion of tumor cells under flow. To trigger firm adhesion and capture under flow, such devices also typically require antibodies against biomarkers thought to be expressed on CTCs. This approach is challenged by the fact that CTCs are now known to exhibit heterogeneous expression of conventional biomarkers. Here, we describe surfactant-nanotube complexes to enhance ES-mediated capture and isolation of tumor cells without the use of capture antibodies. While the majority of tumor cells exhibited weaker rolling adhesion on halloysite nanotubes (HNT) coated with ES, HNT functionalization with the sodium dodecanoate (NaL) surfactant induced a switch to firm cellular adhesion under flow. Conversely, surfactant-nanotube complexes significantly reduced the number of primary human leukocytes captured via ES-mediated adhesion under flow. The switch in tumor cell adhesion was exploited to capture and isolate tumor cells in the absence of EpCAM antibodies, commonly utilized as the gold standard for CTC isolation. Additionally, HNT-NaL complexes were shown to capture tumor cells with low to negligible EpCAM expression, that are not efficiently captured using conventional approaches.

  6. Re-capturing cosmic information

    CERN Document Server

    Seo, Hee-Jong; Dodelson, Scott; Jain, Bhuvnesh; Takada, Masahiro

    2010-01-01

    Gravitational lensing of distant galaxies can be exploited to infer the convergence field as a function of angular position on the sky. The statistics of this field, much like that of the cosmic microwave background (CMB), can be studied to extract information about fundamental parameters in cosmology, most notably the dark energy in the Universe. Unlike the CMB, the distribution of matter in the Universe which determines the convergence field is highly non-Gaussian, reflecting the nonlinear processes which accompanied structure formation. Much of the cosmic information contained in the initial field is therefore unavailable to the standard power spectrum measurements. Here we propose a method for re-capturing cosmic information by using the power spectrum of a simple function of the observed (nonlinear) convergence field. We adapt the approach of Neyrinck et al. (2009) to lensing by using a modified logarithmic transform of the convergence field. The Fourier transform of the log-transformed field has modes t...

  7. Muon capture by helium-3

    International Nuclear Information System (INIS)

    In this paper we study the capture of a negative muon by He3 in the channel μ-+He3+V. Following Primakoff we use the V-A theory of the weak interactions. We include also first order relativistic terms. To describe the initial and final nuclei we have used the most general wave function allowed by the Paul is exclusion principle, assuming that these nuclei are a mixture of an isospin doublet and quadruplet. For the part of the wave function depending on the inter nucleonic distances, we have taken four different function without hard-core, a gaussian and three kinds of Irving type. We present in several tables the results obtained varying gp/gv and gA/gy as well as the amplitudes of the fourteen terms forming the nuclear wave function. (Author) 35 refs

  8. Opportunity Captures 'Lion King' Panorama

    Science.gov (United States)

    2004-01-01

    [figure removed for brevity, see original site] Click on the image for Opportunity Captures 'Lion King' Panorama (QTVR) This approximate true-color panorama, dubbed 'Lion King,' shows 'Eagle Crater' and the surrounding plains of Meridiani Planum. It was obtained by the Mars Exploration Rover Opportunity's panoramic camera on sols 58 and 60 using infrared (750-nanometer), green (530-nanometer) and blue (430-nanometer) filters. This is the largest panorama obtained yet by either rover. It was taken in eight segments using six filters per segment, for a total of 558 images and more than 75 megabytes of data. Additional lower elevation tiers were added to ensure that the entire crater was covered in the mosaic. This panorama depicts a story of exploration including the rover's lander, a thorough examination of the outcrop, a study of the soils at the near-side of the lander, a successful exit from Eagle Crater and finally the rover's next desination, the large crater dubbed 'Endurance'.

  9. Cage-based performance capture

    CERN Document Server

    Savoye, Yann

    2014-01-01

    Nowadays, highly-detailed animations of live-actor performances are increasingly easier to acquire and 3D Video has reached considerable attentions in visual media production. In this book, we address the problem of extracting or acquiring and then reusing non-rigid parametrization for video-based animations. At first sight, a crucial challenge is to reproduce plausible boneless deformations while preserving global and local captured properties of dynamic surfaces with a limited number of controllable, flexible and reusable parameters. To solve this challenge, we directly rely on a skin-detached dimension reduction thanks to the well-known cage-based paradigm. First, we achieve Scalable Inverse Cage-based Modeling by transposing the inverse kinematics paradigm on surfaces. Thus, we introduce a cage inversion process with user-specified screen-space constraints. Secondly, we convert non-rigid animated surfaces into a sequence of optimal cage parameters via Cage-based Animation Conversion. Building upon this re...

  10. PGNAA of human arthritic synovium for boron neutron capture synovectomy

    Energy Technology Data Exchange (ETDEWEB)

    Binello, E.; Yanch, J.C. [Massashucetts Institute of Technology, Cambridge, MA (United States); Shortkroff, S. [Brigham and Women`s Hospital, Boston, MA (United States)

    1997-12-01

    Boron neutron capture synovectomy (BNCS), is a proposed new therapy modality for the treatment of rheumatoid arthritis, an autoimmune disease afflicting the joints. The synovium, which is the membrane lining the joint, becomes inflamed and represents the target tissue for therapy. When a joint is unresponsive to drug treatment, physical removal of the synovium, termed synovectomy, becomes necessary. Existing options include surgery and radiation synovectomy. BNCS has advantages over these options in that it is noninvasive and does not require the administration of radioactive substances. Previous studies have shown that the uptake of {sup 10}B by human arthritic synovium ex vivo is high, ranging from 194 to 545 ppm with an unenriched boron compound. While tissue samples remain viable up to 1 week, ex vivo conditions do not accurately reflect those in vivo. This paper presents results from experiments assessing the washout of boron from the tissue and examines the implications for in vivo studies.

  11. Exercise therapy versus arthroscopic partial meniscectomy for degenerative meniscal tear in middle aged patients

    DEFF Research Database (Denmark)

    Kise, Nina Jullum; Risberg, May Arna; Stensrud, Silje;

    2016-01-01

    clinics in Norway. PARTICIPANTS: 140 adults, mean age 49.5 years (range 35.7-59.9), with degenerative medial meniscal tear verified by magnetic resonance imaging. 96% had no definitive radiographic evidence of osteoarthritis. INTERVENTIONS: 12 week supervised exercise therapy alone or arthroscopic partial....... Our results should encourage clinicians and middle aged patients with degenerative meniscal tear and no definitive radiographic evidence of osteoarthritis to consider supervised exercise therapy as a treatment option.Trial registration www.clinicaltrials.gov (NCT01002794)....

  12. Trial NCT01950403 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  13. Trial NCT01141231 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  14. Trial NCT02237183 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  15. Trial NCT01382082 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  16. Trial NCT02273362 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  17. Trial NCT02112188 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  18. Trial NCT01824836 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  19. Trial NCT01968798 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  20. Trial NCT01849250 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  1. Trial NCT02116530 | Division of Cancer Prevention

    Science.gov (United States)

    The Division of Cancer Prevention (DCP) conducts and supports research to determine a person's risk of cancer and to find ways to reduce the risk. This knowledge is critical to making progress against cancer because risk varies over the lifespan as genetic and epigenetic changes can transform healthy tissue into invasive cancer.

  2. NCT and Developmental Psychology: A Welcome Rapprochement

    Science.gov (United States)

    Gauvain, Mary

    2013-01-01

    For over 50 years, developmental psychologists have conducted research around the world to understand the relation between culture and cognition. In fact, psychologists have been interested in this topic for over a century. In the late 1800s, Wundt introduced "Elements of Folk Psychology," the study of how culture becomes part of higher…

  3. Radiation Therapy

    Science.gov (United States)

    ... therapy. At this time, you will have a physical exam , talk about your medical history , and maybe have imaging tests . Your doctor or nurse will discuss external beam radiation therapy, its benefits and side effects, and ways you can care ...

  4. Earth--Mars Transfers with Ballistic Capture

    CERN Document Server

    Topputo, Francesco

    2014-01-01

    We construct a new type of transfer from the Earth to Mars, which ends in ballistic capture. This results in a substantial savings in capture $\\Delta v$ from that of a classical Hohmann transfer under certain conditions. This is accomplished by first becoming captured at Mars, very distant from the planet, and then from there, following a ballistic capture transfer to a desired altitude within a ballistic capture set. This is achieved by manipulating the stable sets, or sets of initial conditions whose orbits satisfy a simple definition of stability. This transfer type may be of interest for Mars missions because of lower capture $\\Delta v$, moderate flight time, and flexibility of launch period from the Earth.

  5. A survey of the Carbon Capture

    International Nuclear Information System (INIS)

    The concentration of carbon dioxide, one of the most important representatives of greenhouse gases in the atmosphere continues to rise. Fossil fuels burned in thermal power plants currently represent 80% of total energy production around the world and are the largest point sources of CO2, accounting for approximately 40% of total CO2 emissions. There are several options for reducing CO2 emissions: reducing demand, improving production efficiency and carbon capture and storage (CCS, carbon capture and storage). Capture and storage of carbon dioxide is generally a three-step process: 1st Capture and compression of combustion products, 2nd transport (mostly pipeline) and 3rd utilization (eg. production of urea, beverage industry, production of dry ice, etc.). Technologies for CO2 capturing used in power plants burning fossil fuels can be divided into four groups, each of which requires a completely different approach to CO2 capture.

  6. New carbon-carbon linked amphiphilic carboranyl-porphyrins as boron neutron capture agents

    International Nuclear Information System (INIS)

    Novel amphiphilic carboranyl-porphyrins have been synthesized for Boron Neutron Capture Therapy (BNCT). These compounds have carbon-carbon bonds between the carborane residues and the porphyrin meso-phenyl groups, and contain 28-31% boron by weight . (author)

  7. Therapy Services.

    Science.gov (United States)

    Austin Independent School District, TX.

    Reviewed are the goals and activities of the therapy services in the Austin Early Childhood Special Education Program. Specific sections detail activities for speech therapy (such as diagnostic assessment, habilitation, consultation, and reporting procedures), occupational therapy (including identification and assessment, and services to children,…

  8. Measurements of neutron capture cross sections

    International Nuclear Information System (INIS)

    A review of measurement techniques for the neutron capture cross sections is presented. Sell transmission method, activation method, and prompt gamma-ray detection method are described using examples of capture cross section measurements. The capture cross section of 238U measured by three different prompt gamma-ray detection methods (large liquid scintillator, Moxon-Rae detector, and pulse height weighting method) are compared and their discrepancies are resolved. A method how to derive the covariance is described. (author)

  9. Neutron capture cross section measurement techniques

    International Nuclear Information System (INIS)

    A review of currently-used techniques to measure neutron capture cross sections is presented. Measurements involving use of total absorption and Moxon-Rae detectors are based on low-resolution detection of the prompt γ-ray cascades following neutron captures. In certain energy ranges activation methods are convenient and useful. High resolution γ-ray measurements with germanium detectors can give information on the parameters of resonance capture states. The use of these techniques is described. (U.S.)

  10. Radioactive proton capture on {sup 6}He

    Energy Technology Data Exchange (ETDEWEB)

    Sauvan, E.; Marques, F.M. [Caen Univ., 14 (France). Lab. de Physique Corpusculaire; Wilschut, H.W. [Kernfysich Versneller Instituut, Groningen (Netherlands)

    2001-03-01

    Radiative capture of protons is investigated as a probe of clustering in nuclei far from stability. The first such measurement on a halo nucleus is reported here for the reaction {sup 6}He(p,{gamma}) at 40 MeV. Capture into {sup 7}Li is observed as the strongest channel. In addition, events have been recorded that may be described by quasi-free capture on halo neutron, the {alpha} core and {sup 5}He. The possibility of describing such events by capture into the continuum of {sup 7}Li is also discussed. (authors)

  11. Capture myopathy in an endangered sandhill crane (Grus canadensis pulla)

    Science.gov (United States)

    Carpenter, J.W.; Thomas, N.J.; Reeves, S.

    1991-01-01

    Despite precautions to protect cranes, a 3-year-old endangered Mississippi sandhill crane (Grus canadensis pulla) was found caught in a leghold trap in Gautier, Mississippi, on 11 November 1987. The bird could have been in the trap for up to 16 hr and was standing and struggling to escape when it was discovered. Serum chemistries of the crane on 12 November revealed elevated lactic dehydrogenase (2,880 IU/L), alanine aminotransferase (ALT) (152 IU/L), and aspartate aminotransferase (AST) (>1,000 IU/L) values. Following surgical amputation of a fractured toe, the bird never attempted to stand and was unable to stand even when manually supported. Radiographic and physical examination of both legs did not reveal any anatomical abnormalities. Despite medical care, including supportive therapy, no improvement was observed in the bird's ability to stand and to support itself, and the bird died on 19 November. Serum chemistries and the postmortem and histopathologic findings were compatible with capture myopathy described in other species. Because of the possible susceptibility of long-legged birds such as the Mississippi sandhill crane to capture myopathy, special care must be taken when trapping, handling, chemically immobilizing, and transporting these species. In addition, precautions must be taken when conducting a predator-control program to ensure that nontarget wildlife are unlikely to encounter traps. Capture myopathy has only rarely been observed in wild birds, and this case represents the first report in a Mississippi sandhill crane.

  12. A historically controlled, single-arm, multi-centre, prospective trial to evaluate the safety and efficacy of MonoMax® suture material for abdominal wall closure after primary midline laparotomy. ISSAAC-Trial [NCT005725079

    Directory of Open Access Journals (Sweden)

    Franck Annette

    2008-07-01

    Full Text Available Abstract Background Several randomized controlled trials have compared different suture materials and techniques for abdominal wall closure with respect to the incidence of incisional hernias after midline laparotomy and shown that it remains, irrespective of the methods used, considerably high, ranging from 9% to 20%. The development of improved suture materials which would reduce postoperative complications may help to lower its frequency. Design This is a historically controlled, single-arm, multi-centre, prospective trial to evaluate the safety of MonoMax® suture material for abdominal wall closure in 150 patients with primary elective midline incisions. INSECT patients who underwent abdominal closure using Monoplus® and PDS® will serve as historical control group. The incidences of wound infections and of burst abdomen are defined as composite primary endpoints. Secondary endpoints are the frequency of incisional hernias within one year after operation and safety. To ensure adequate comparability in surgical performance and recruitment, the 4 largest centres of the INSECT-Trial will participate. After hospital discharge, the investigators will examine the enrolled patients again at 30 days and at 12 ± 1 months after surgery. Conclusion This historically controlled, single-arm, multi-centre, prospective ISSAAC trial aims to assess whether the use of an ultra-long-lasting absorbable monofilament suture material is safe and efficient. Trial registration NCT005725079

  13. The study on the changes of NCT measured intraocular pressure before and after LASIK%LASIK术后非接触式眼压计测量值的变化

    Institute of Scientific and Technical Information of China (English)

    郭萌; 陈剑; 刘珏

    2009-01-01

    Objective To investigate the factors affecting noncontact tonometer measurement of intraocular pres-sure after laser in situ keratomileusis(LASIK). Methods The intraocular pressure readings of 159 cases were measured with noncontact tonometer(NCT) before and six months after LASIK was performed. Results The intraocular pressure readings after LASIK were much lower than that before LASIK with statistically significant difference. Conclusion The intraocular pressure readings are lower after LASIK, whcich may be caused by the changes in corneal thickness because of laser treatment.%目的 探讨准分子激光原位角膜磨镶术(LASIK)后影响眼压测量值的因素.方法 对实施准分子激光原位角膜磨镶术(LAISK)的159例患者,于术前和术后6个月分别以非接触式眼压计测量眼压,分析眼压变化的原因.结果 LASIK术后眼压测量值明显低于术前,差异有统计学意义.结论 LASIK术后眼压明显下降,这与激光切削角膜变薄有关.

  14. A randomized trial to assess the impact of opinion leader endorsed evidence summaries on the use of secondary prevention strategies in patients with coronary artery disease: the ESP-CAD trial protocol [NCT00175240

    OpenAIRE

    Ghali William A.; Majumdar Sumit R; Graham Michelle; Fradette Miriam; McAlister Finlay A; Williams Randall; Tsuyuki Ross T; McMeekin James; Grimshaw Jeremy; Knudtson Merril L

    2006-01-01

    Abstract Background Although numerous therapies have been shown to be beneficial in the prevention of myocardial infarction and/or death in patients with coronary disease, these therapies are under-used and this gap contributes to sub-optimal patient outcomes. To increase the uptake of proven efficacious therapies in patients with coronary disease, we designed a multifaceted quality improvement intervention employing patient-specific reminders delivered at the point-of-care, with one-page tre...

  15. Electron capture to the continuum

    International Nuclear Information System (INIS)

    The second order Oppenheimer-Brinkman-Kramers approximation is used to derive simple analytical formulae, evaluated to the lowest order in the fine-structure constant α in the numerator, for the differential cross section for electron capture to the continuum (ECC) by incident bare ions having velocity ν from target hydrogenic atomic systems. Relativistic as well as non-relativistic forms are derived. Comparison of the theory with the experimental data of Dahl and Andersen et al for H+, He2+ + He collisions is fairly satisfactory for energies >50 keV amu-1. However, although the velocity dependence obtained by Andersen et al is ν-11.3±0.2 in the range of impact energies 1-2.6 MeV amu-1, this does not imply that the asymptotic ν-11 velocity dependence given by the non-relativistic second-order OBK cross section is almost attained. It is shown that this cannot happen until an energy >500 MeV amu-1 is reached where allowance for relativity produces a considerable change in the energy fall off. A modification of the second-order OBK approximation may be expanded to first order in the atomic number ΖP of the projectile ion to get simple formulae for the yield of continuum electrons and the cusp asymmetry factor β. The agreement with the data of Andersen et al for β is fair at impact energies >0.5 MeV amu-1P-1 but the situation is unclear at energies -1 ΖP-1 where the data of different experimenters doe not agree with each other and CDW calculations produce low values of β. (author)

  16. Experience machines : Capturing and retrieving personal content

    NARCIS (Netherlands)

    Werkhoven, P.

    2005-01-01

    Fundamental to human existence is the ability to capture, memorise and retrieve personal experiences and to share them with others. Can systems help us to capture and retrieve experiences? After motors have supplemented our muscles and sensors have supplemented our senses, emerging computer systems

  17. Radiative proton capture on He-6

    NARCIS (Netherlands)

    Sauvan, E; Marques, FM; Wilschut, HW; Orr, NA; Angelique, JC; Borcea, C; Catford, WN; Clarke, NM; Descouvemont, P; Diaz, J; Grevy, S; Kugler, A; Kravchuk, [No Value; Labiche, M; Le Brun, C; Lienard, E; Lohner, H; Mittig, W; Ostendorf, RW; Pietri, S; Roussel-Chomaz, P; Saint Laurent, MG; Savajols, H; Wagner, [No Value; Yahlali, N

    2001-01-01

    Radiative capture of protons is investigated as a probe of clustering in nuclei far from stability. The first such measurement on a halo nucleus is reported here for the reaction He-6(p, gamma) at 40 MeV. Capture into Li-7 is observed as the strongest channel. In addition, events have been recorded

  18. Screen captures to support switching attention

    NARCIS (Netherlands)

    Gellevij, Mark; Meij, van der Hans

    2002-01-01

    The study set out to validate the supportive role of screen captures for switching attention. Forty-two participants learned how to work with Microsoft Excel with a paper manual. There were three types of manuals: a textual manual, a visual manual with full-screen captures, and a visual manual with

  19. Encapsulated liquid sorbents for carbon dioxide capture.

    Science.gov (United States)

    Vericella, John J; Baker, Sarah E; Stolaroff, Joshuah K; Duoss, Eric B; Hardin, James O; Lewicki, James; Glogowski, Elizabeth; Floyd, William C; Valdez, Carlos A; Smith, William L; Satcher, Joe H; Bourcier, William L; Spadaccini, Christopher M; Lewis, Jennifer A; Aines, Roger D

    2015-02-05

    Drawbacks of current carbon dioxide capture methods include corrosivity, evaporative losses and fouling. Separating the capture solvent from infrastructure and effluent gases via microencapsulation provides possible solutions to these issues. Here we report carbon capture materials that may enable low-cost and energy-efficient capture of carbon dioxide from flue gas. Polymer microcapsules composed of liquid carbonate cores and highly permeable silicone shells are produced by microfluidic assembly. This motif couples the capacity and selectivity of liquid sorbents with high surface area to facilitate rapid and controlled carbon dioxide uptake and release over repeated cycles. While mass transport across the capsule shell is slightly lower relative to neat liquid sorbents, the surface area enhancement gained via encapsulation provides an order-of-magnitude increase in carbon dioxide absorption rates for a given sorbent mass. The microcapsules are stable under typical industrial operating conditions and may be used in supported packing and fluidized beds for large-scale carbon capture.

  20. CO2 Capture by Cement Raw Meal

    DEFF Research Database (Denmark)

    Pathi, Sharat Kumar; Lin, Weigang; Illerup, Jytte Boll;

    2013-01-01

    The cement industry is one of the major sources of CO2 emissions and is likely to contribute to further increases in the near future. The carbonate looping process has the potential to capture CO2 emissions from the cement industry, in which raw meal for cement production could be used...... as the sorbent. Cyclic experiments were carried out in a TGA apparatus using industrial cement raw meal and synthetic raw meal as sorbents, with limestone as the reference. The results show that the CO2 capture capacities of the cement raw meal and the synthetic raw meal are comparable to those of pure limestone....... The CO2 capture capacity of limestone in the raw meal is lower than for pure limestone. The difference in the CO2 capture capacity decreases with an increase in cycle number. The calcination conditions and composition are major factors that influence the CO2 capture capacity of limestone. At 850 °C in N2...

  1. 硼中子俘获疗法对胶质瘤干细胞增殖和细胞周期的影响%Effect of boron neutron capture therapy on cell proliferation and cell cycle arrest in glioma stem cells

    Institute of Scientific and Technical Information of China (English)

    孙婷; 钱兴龙; 李炎炎; 张紫竹; 李斌; 陈桂林; 韦永新; 谢学顺; 周幽心

    2014-01-01

    Objective To study the effect and mechanism of boron neutron capture therapy (BNCT) on cell cycle procession in human glioma stem cells (GSCs) in vitro,and to analyze the difference of sensitivity for BNCT on GSCs and glioma cells.Methods Firstly,uptake of boronophenylalarine (BPA) on human GSCs SU2 and glioma cells SHG-44 was detected.Then the cells enriched boron-10 (10B) were irradiated by In-Hospital Neutron Irradiator (IHNI-1).The radiation sensitivity was measured using clonogenic survival assay.The proliferation was examined by MTT assay.The cell cycle procession was determined using flow cytometry.The protein expression of cyclin B1,CDK1 and P21[WAF1] were detected by Western blot.Results 10B concentration of SU2 and SHG-44 cells arrived at (1.76 ±0.28) and (2.50 ±0.12) μg/107cells at 24 h in 5 mMBPA.After radiation by IHNI-1,the survival fraction and viability of cells enriched 10B were decreased significantly (P < 0.05 orP < 0.01),compared with those of 10B-free.The BNCT sensitivity of SU2 cells was lower than that of SHG-44 cells (P < 0.05).The proportion of G2/M phase of SU2 and SHG-44 cells was increased after BNCT compared with that of 10B-free(P < 0.05).The protein levels of cyclin B1 and CDK1 were decreased(P < 0.01),and that of P21[WAF1] was increased(P < 0.01).Conclusions The BNCT sensitivity of GSCs was lower than that of glioma cells.BNCT could inhibite cell regeneration and proliferation and make G2/M to be blocked by inhibition of cell cycle protein formation.%目的 研究硼中子俘获疗法(BNCT)对体外培养人胶质瘤干细胞(GSCs)周期进程的影响及机制,比较GSCs和胶质瘤细胞株SHG-44对BNCT敏感性的差异.方法 首先检测人GSCsSU2和人胶质瘤细胞株SHG-44吸收含硼化合物二羟基苯丙氨酸硼(BPA)的情况,然后采用医院中子照射器(IHNI-1)对含硼(10B)细胞进行照射,克隆存活实验检测细胞的放射敏感性,MTT法检测细胞增殖率,流式细胞

  2. Proton therapy

    International Nuclear Information System (INIS)

    Proton therapy has become a subject of considerable interest in the radiation oncology community and it is expected that there will be a substantial growth in proton treatment facilities during the next decade. I was asked to write a historical review of proton therapy based on my personal experiences, which have all occurred in the United States, so therefore I have a somewhat parochial point of view. Space requirements did not permit me to mention all of the existing proton therapy facilities or the names of all of those who have contributed to proton therapy. (review)

  3. Capture of irregular satellites at Jupiter

    Energy Technology Data Exchange (ETDEWEB)

    Nesvorný, David; Vokrouhlický, David; Deienno, Rogerio [Department of Space Studies, Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States)

    2014-03-20

    The irregular satellites of outer planets are thought to have been captured from heliocentric orbits. The exact nature of the capture process, however, remains uncertain. We examine the possibility that irregular satellites were captured from the planetesimal disk during the early solar system instability when encounters between the outer planets occurred. Nesvorný et al. already showed that the irregular satellites of Saturn, Uranus, and Neptune were plausibly captured during planetary encounters. Here we find that the current instability models present favorable conditions for capture of irregular satellites at Jupiter as well, mainly because Jupiter undergoes a phase of close encounters with an ice giant. We show that the orbital distribution of bodies captured during planetary encounters provides a good match to the observed distribution of irregular satellites at Jupiter. The capture efficiency for each particle in the original transplanetary disk is found to be (1.3-3.6) × 10{sup –8}. This is roughly enough to explain the observed population of jovian irregular moons. We also confirm Nesvorný et al.'s results for the irregular satellites of Saturn, Uranus, and Neptune.

  4. Capture of irregular satellites at Jupiter

    International Nuclear Information System (INIS)

    The irregular satellites of outer planets are thought to have been captured from heliocentric orbits. The exact nature of the capture process, however, remains uncertain. We examine the possibility that irregular satellites were captured from the planetesimal disk during the early solar system instability when encounters between the outer planets occurred. Nesvorný et al. already showed that the irregular satellites of Saturn, Uranus, and Neptune were plausibly captured during planetary encounters. Here we find that the current instability models present favorable conditions for capture of irregular satellites at Jupiter as well, mainly because Jupiter undergoes a phase of close encounters with an ice giant. We show that the orbital distribution of bodies captured during planetary encounters provides a good match to the observed distribution of irregular satellites at Jupiter. The capture efficiency for each particle in the original transplanetary disk is found to be (1.3-3.6) × 10–8. This is roughly enough to explain the observed population of jovian irregular moons. We also confirm Nesvorný et al.'s results for the irregular satellites of Saturn, Uranus, and Neptune.

  5. Towards the Biological Understanding of CTC: Capture Technologies, Definitions and Potential to Create Metastasis

    Directory of Open Access Journals (Sweden)

    Ana M.C. Barradas

    2013-12-01

    Full Text Available Circulating Tumor Cells (CTC are rare cells originated from tumors that travel into the blood stream, extravasate to different organs of which only a small fraction will develop into metastasis. The presence of CTC enumerated with the CellSearch system is associated with a relative short survival and their continued presence after the first cycles of therapy indicates a futile therapy in patients with metastatic carcinomas. Detailed characterization of CTC holds the promise to enable the choice of the optimal therapy for the individual patients during the course of the disease. The phenotype, physical and biological properties are however not well understood making it difficult to assess the merit of recent technological advancements to improve upon the capture of CTC or to evaluate their metastatic potential. Here we will discuss the recent advances in the classification of CTC captured by the CellSearch system, the implications of their features and numbers. Latest capture platforms are reviewed and placed in the light of technology improvements needed to detect CTC. Physical properties, phenotype, viability and proliferative potential and means to assess their proliferation and metastatic capacity will be summarized and placed in the context of the latest CTC capture platforms.

  6. The effect of antipsychotic medication on sexual function and serum prolactin levels in community-treated schizophrenic patients: results from the Schizophrenia Trial of Aripiprazole (STAR study (NCT00237913

    Directory of Open Access Journals (Sweden)

    Pans Miranda

    2008-12-01

    Full Text Available Abstract Background The aim of this paper is to evaluate the effect of antipsychotics for the treatment of schizophrenia in a community based study on sexual function and prolactin levels comparing the use of aripiprazole and standard of care (SOC, which was a limited choice of three widely used and available antipsychotics (olanzapine, quetiapine or risperidone (The Schizophrenia Trial of Aripiprazole [STAR] study [NCT00237913]. Method This open-label, 26-week, multi-centre, randomised study compared aripiprazole to SOC (olanzapine, quetiapine or risperidone in patients with schizophrenia (DSM-IV-TR criteria. The primary effectiveness variable was the mean total score of the Investigator Assessment Questionnaire (IAQ at Week 26. The outcome research variables included the Arizona Sexual Experience scale (ASEX. This along with the data collected on serum prolactin levels at week 4, 8, 12, 18 and 26 will be the focus of this paper. Results A total of 555 patients were randomised to receive aripiprazole (n = 284 or SOC (n = 271. Both treatment groups experienced improvements in sexual function from baseline ASEX assessments. However at 8 weeks the aripiprazole treatment group reported significantly greater improvement compared with the SOC group (p = 0.007; OC. Although baseline mean serum prolactin levels were similar in the two treatment groups (43.4 mg/dL in the aripiprazole group and 42.3 mg/dL in the SOC group, p = NS at Week 26 OC, mean decreases in serum prolactin were 34.2 mg/dL in the aripiprazole group, compared with 13.3 mg/dL in the SOC group (p Conclusion The study findings suggest that aripiprazole has the potential to reduce sexual dysfunction, which in turn might improve patient compliance.

  7. The carbon dioxide capture and geological storage

    International Nuclear Information System (INIS)

    This road-map proposes by the Group Total aims to inform the public on the carbon dioxide capture and geological storage. One possible means of climate change mitigation consists of storing the CO2 generated by the greenhouse gases emission in order to stabilize atmospheric concentrations. This sheet presents the CO2 capture from lage fossil-fueled combustion installations, the three capture techniques and the CO2 transport options, the geological storage of the CO2 and Total commitments in the domain. (A.L.B.)

  8. Screen captures to support switching attention

    OpenAIRE

    Gellevij, Mark; Meij, van der, T.

    2002-01-01

    The study set out to validate the supportive role of screen captures for switching attention. Forty-two participants learned how to work with Microsoft Excel with a paper manual. There were three types of manuals: a textual manual, a visual manual with full-screen captures, and a visual manual with a mixture of partial- and full-screen captures. The findings show that participants in all conditions looked up from the manual to the screen on about 97% of the cases in which such a switch was ca...

  9. Understanding Motion Capture for Computer Animation

    CERN Document Server

    Menache, Alberto

    2010-01-01

    The power of today's motion capture technology has taken animated characters and special effects to amazing new levels of reality. And with the release of blockbusters like Avatar and Tin-Tin, audiences continually expect more from each new release. To live up to these expectations, film and game makers, particularly technical animators and directors, need to be at the forefront of motion capture technology. In this extensively updated edition of Understanding Motion Capture for Computer Animation and Video Games, an industry insider explains the latest research developments in digital design

  10. Carbon dioxide capture and geological storage

    OpenAIRE

    2013-01-01

    Sustainable Carbon dioxide Capture and Storage, or CCS, can be achieved using geological means, an approach that differs in many ways from CO2 capture and storage in vegetation. Firstly, it differs because this latter approach enables CO2 to be stored only temporarily – for less than one year in annual plants or for several centuries in tree phytomass. Secondly, CO2 capture is associated with bioconversion of the sun’s energy which is then stored in biochemical form in the phytomass. As the t...

  11. Gravitational Capture of Asteroids by Gas Drag

    Directory of Open Access Journals (Sweden)

    E. Vieira Neto

    2009-01-01

    captured by the planet got its velocity reduced and could been trapped as an irregular satellite. It is well known that, depending on the time scale of the gas envelope, an asteroid will spiral and collide with the planet. So, we simulate the passage of the asteroid in the gas envelope with its density decreasing along the time. Using this approach, we found effective captures, and have a better understanding of the whole process. Finally, we conclude that the origin of the irregular satellites cannot be attributed to the gas drag capture mechanism alone.

  12. Sweat Therapy.

    Science.gov (United States)

    Colmant, Stephen A.; Merta, Rod J.

    2000-01-01

    A study combined group sweating and group counseling. Four adolescent boys with disruptive behavior disorders participated in 12 sweat therapy sessions. They reported the sessions useful for sharing personal concerns and receiving assistance with problem solving. Three boys showed improvement in self-esteem. Advantages of sweat therapy over other…

  13. Gene therapy.

    OpenAIRE

    Mota Biosca, Anna

    1992-01-01

    Applications of gene therapy have been evaluated in virtually every oral tissue, and many of these have proved successful at least in animal models. While gene therapy will not be used routinely in the next decade, practitioners of oral medicine should be aware of the potential of this novel type of treatment that doubtless will benefit many patients with oral diseases.

  14. Development of local radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hoon; Lim, Sang Moo; Choi, Chang Woon; Chai, Jong Su; Kim, Eun Hee; Kim, Mi Sook; Yoo, Seong Yul; Cho, Chul Koo; Lee, Yong Sik; Lee, Hyun Moo

    1999-04-01

    The major limitations of radiation therapy for cancer are the low effectiveness of low LET and inevitable normal tissue damage. Boron Neutron Capture Therapy (BNCT) is a form of potent radiation therapy using Boron-10 having a high propensityof capturing theraml neutrons from nuclear reactor and reacting with a prompt nuclear reaction. Photodynamic therapy is a similiar treatment of modality to BNCT using tumor-seeking photosenistizer and LASER beam. If Boron-10 and photosensitizers are introduced selectively into tumor cells, it is theoretically possible to destroy the tumor and to spare the surrounding normal tissue. Therefore, BNCT and PDT will be new potent treatment modalities in the next century. In this project, we performed PDT in the patients with bladder cancers, oropharyngeal cancer, and skin cancers. Also we developed I-BPA, new porphyrin compounds, methods for estimation of radiobiological effect of neutron beam, and superficial animal brain tumor model. Furthermore, we prepared preclinical procedures for clinical application of BNCT, such as the macro- and microscopic dosimetry, obtaining thermal neutron flux from device used for fast neutron production in KCCH have been performed.

  15. Reactive Capture of Carbon Dioxide Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I SBIR, Reactive Innovations, LLC (RIL) proposes to develop a compact and lightweight electrochemical to capture carbon dioxide in the martian...

  16. Preparation of porous materials for radionuclides capture

    International Nuclear Information System (INIS)

    Porous materials showing promise for radionuclide capture from water at contaminated sites were prepared. Nanoporous materials (size of pores 1-100 nm) and some polymers are well suited to this purpose owing their affinity for selected radionuclides. Nanoporous metal oxides and silica gel with styrene-divinylbenzene-TODGA-modified surface were prepared, characterized and tested for radionuclide (227Ac, 227Th, 223Ra) capture efficiency. (orig.)

  17. Optimal Carbon Capture and Storage Policies

    OpenAIRE

    Ayong Le Kama, Alain; Mouez FODHA; Lafforgue, Gilles

    2011-01-01

    Following the IPCC's report (2005), which recommended the development and the use of carbon capture and sequestration (CCS) technologies in order to achieve the environmental goals, defined by the Kyoto Protocol, the issue addressed in this paper concerns the optimal strategy regarding the long-term use of CCS technologies. The aim of this paper is to study the optimal carbon capture and sequestration policy. The CCS technologies has motivated a number of empirical studies, via complex int...

  18. Last chance for carbon capture and storage

    OpenAIRE

    Scott, Vivian; Gilfillan, Stuart; Markusson, Nils; Chalmers, Hannah; Haszeldine, Stuart

    2013-01-01

    Anthropogenic energy-related CO2 emissions are higher than ever. With new fossil-fuel power plants, growing energy-intensive industries and new sources of fossil fuels in development, further emissions increase seems inevitable. The rapid application of carbon capture and storage is a much heralded means to tackle emissions from both existing and future sources. However, despite extensive and successful research and development, progress in deploying carbon capture and storage has stalled. No...

  19. Data capture and processing. [for Space Station

    Science.gov (United States)

    Lyon, John; Smith, Gene; Carper, Richard

    1987-01-01

    A systems concept developed in response to the specific requirements imposed by the Space Station and affiliated instrumentation is described. Particular attention is given to those subsystems associated with initial data capture, handling, routing, and distribution control for return link data via the Tracking and Data Relay Satellite System. The conceived approach, designated the Customer Data and Operations System, includes a data interface facility and a data handling center whose functions are data capture, demultiplexing and routing, early preprocessing, and ancillary data handling.

  20. CAPTURE OF TROJANS BY JUMPING JUPITER

    International Nuclear Information System (INIS)

    Jupiter Trojans are thought to be survivors of a much larger population of planetesimals that existed in the planetary region when planets formed. They can provide important constraints on the mass and properties of the planetesimal disk, and its dispersal during planet migration. Here, we tested a possibility that the Trojans were captured during the early dynamical instability among the outer planets (aka the Nice model), when the semimajor axis of Jupiter was changing as a result of scattering encounters with an ice giant. The capture occurs in this model when Jupiter's orbit and its Lagrange points become radially displaced in a scattering event and fall into a region populated by planetesimals (that previously evolved from their natal transplanetary disk to ∼5 AU during the instability). Our numerical simulations of the new capture model, hereafter jump capture, satisfactorily reproduce the orbital distribution of the Trojans and their total mass. The jump capture is potentially capable of explaining the observed asymmetry in the number of leading and trailing Trojans. We find that the capture probability is (6-8) × 10–7 for each particle in the original transplanetary disk, implying that the disk contained (3-4) × 107 planetesimals with absolute magnitude H disk ∼ 14-28 MEarth, is consistent with the mass deduced from recent dynamical simulations of the planetary instability.

  1. Clonal evolution of AML on novel FMS-like tyrosine kinase-3 (FLT3 inhibitor therapy with evolving actionable targets

    Directory of Open Access Journals (Sweden)

    Pashtoon M. Kasi

    2016-01-01

    Full Text Available For acute myeloid leukemia (AML, identification of activating mutations in the FMS-like tyrosine kinase-3 (FLT3 has led to the development of several FLT3-inhibitors. Here we present clinical and next generation sequencing data at the time of progression of a patient on a novel FLT3-inhibitor clinical trial (ASP2215 to show that employing therapeutic interventions with these novel targeted therapies can lead to consequences secondary to selective pressure and clonal evolution of cancer. We describe novel findings alongside data on treatment directed towards actionable aberrations acquired during the process. (Clinical Trial: NCT02014558; registered at: 〈https://clinicaltrials.gov/ct2/show/NCT02014558〉

  2. Synovectomy by Neutron capture; Sinovectomia por captura de neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Torres M, C. [Centro Regional de Estudios Nucleares, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Penuela, 98000 Zacatecas (Mexico)

    1998-12-31

    The Synovectomy by Neutron capture has as purpose the treatment of the rheumatoid arthritis, illness which at present does not have a definitive curing. This therapy requires a neutron source for irradiating the articulation affected. The energy spectra and the intensity of these neutrons are fundamental since these neutrons induce nuclear reactions of capture with Boron-10 inside the articulation and the freely energy of these reactions is transferred at the productive tissue of synovial liquid, annihilating it. In this work it is presented the neutron spectra results obtained with moderator packings of spherical geometry which contains in its center a Pu{sup 239} Be source. The calculations were realized through Monte Carlo method. The moderators assayed were light water, heavy water base and the both combination of them. The spectra obtained, the average energy, the neutron total number by neutron emitted by source, the thermal neutron percentage and the dose equivalent allow us to suggest that the moderator packing more adequate is what has a light water thickness 0.5 cm (radius 2 cm) and 24.5 cm heavy water (radius 26.5 cm). (Author)

  3. Physical Therapy and Occupational Therapy in Progeria

    Science.gov (United States)

    Physical Therapy and Occupational Therapy in Progeria Information for Families and Caretakers from The Progeria Research Foundation Written ... accelerated aging in children. Children with Progeria need Physical Therapy (PT) and Occupational Therapy (OT) as often as ...

  4. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    Energy Technology Data Exchange (ETDEWEB)

    Kitrou, Panagiotis M., E-mail: panoskitrou@gmail.com [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece); Katsanos, Konstantinos [Department of Interventional Radiology, Guy' s and St. Thomas’ Hospitals, NHS Foundation Trust, King' s Health Partners, London SE1 7EH (United Kingdom); Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece)

    2015-03-15

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  5. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    International Nuclear Information System (INIS)

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  6. Evaluating an in-home multicomponent cognitive behavioural programme to manage concerns about falls and associated activity avoidance in frail community-dwelling older people: Design of a randomised control trial [NCT01358032

    Directory of Open Access Journals (Sweden)

    van Rossum Erik

    2011-09-01

    facilitators; protocol adherence by participants (engagement in exposure and homework; opinions about the programme of participants and facilitators; perceived benefits and achievements; and experienced barriers. The economic evaluation examines the impact on health-care utilisation, as well as related costs. Discussion A total number of 389 participants is included in the study. Final results are expected in 2012. Trial registration NCT01358032

  7. A cluster randomized trial to assess the impact of clinical pathways for patients with stroke: rationale and design of the Clinical Pathways for Effective and Appropriate Care Study [NCT00673491

    Directory of Open Access Journals (Sweden)

    Barbieri Antonella

    2008-11-01

    result in poor coordination or inefficiencies in patient treatment, and clinical pathways can significantly improve the outcomes of these patients. It is proposed that this study will test a new hypothesis and provide evidence of how clinical pathways can work. Trial Registration ClinicalTrials.gov ID [NCT00673491

  8. The value of episodic, intensive blood glucose monitoring in non-insulin treated persons with type 2 diabetes: Design of the Structured Testing Program (STeP Study, a cluster-randomised, clinical trial [NCT00674986

    Directory of Open Access Journals (Sweden)

    Jelsovsky Zhihong

    2010-05-01

    SMBG by both patients and physicians. Utilization of per protocol and intent-to-treat analyses facilitates a comprehensive assessment of the intervention. Use of practice site cluster-randomisation reduces the potential for intervention contamination, and inclusion criteria (HbA1c ≥ 7.5% reduces the possibility of floor effects. Inclusion of multiple dependent variables allows us to assess the broader impact of the intervention, including changes in patient and physician attitudes and behaviours. Trial Registration Current Controlled Trials NCT00674986.

  9. Getting ready for carbon capture and storage by issuing capture options

    OpenAIRE

    Xi Liang; David Reiner; Jon Gibbins; Jia Li

    2010-01-01

    A capture option is an option contract where the option holder can exercise a contract to retrofit an existing fossil fuel plant to capture carbon dioxide (rm CO 2 ) on or before a fixed date. We suggest that new thermal power plants, particularly those in developing countries, consider issuing capture options at the design stage, because the sellers—the owners of newly built thermal power plants—may then invest in making these plants rm CO 2 capture ready (CCR) to optimise returns from selli...

  10. Capture-S, a nontreponemal solid-phase erythrocyte adherence assay for serological detection of syphilis.

    OpenAIRE

    Stone, D L; Moheng, M C; Rolih, S; Sinor, L T

    1997-01-01

    A solid-phase erythrocyte adherence assay has been developed for the serological detection of reagin antibodies in syphilis. Capture-S (Immucor, Inc., Norcross, Ga.) is a nontreponemal, qualitative screening test for the detection of immunoglobulin G (IgG) and IgM antilipid antibodies in serum or plasma samples from blood donors. The Capture-S assay utilizes a modified Venereal Disease Research Laboratory antigen bound to microtitration wells and anti-IgG- plus anti-IgM-coated indicator eryth...

  11. Oxygen Therapy

    Science.gov (United States)

    Oxygen therapy is a treatment that provides you with extra oxygen. Oxygen is a gas that your body needs to function. Normally, your lungs absorb oxygen from the air you breathe. But some conditions ...

  12. Oxygen Therapy

    Science.gov (United States)

    ... therapy works, it helps to understand how your respiratory system works. This system is a group of organs and tissues that help you breathe. The respiratory system includes the airways and lungs. The airways carry ...

  13. Selective particle capture by asynchronously beating cilia

    Science.gov (United States)

    Ding, Yang; Kanso, Eva

    2015-12-01

    Selective particle filtration is fundamental in many engineering and biological systems. For example, many aquatic microorganisms use filter feeding to capture food particles from the surrounding fluid, using motile cilia. One of the capture strategies is to use the same cilia to generate feeding currents and to intercept particles when the particles are on the downstream side of the cilia. Here, we develop a 3D computational model of ciliary bands interacting with flow suspended particles and calculate particle trajectories for a range of particle sizes. Consistent with experimental observations, we find optimal particle sizes that maximize capture rate. The optimal size depends nonlinearly on cilia spacing and cilia coordination, synchronous vs. asynchronous. These parameters affect the cilia-generated flow field, which in turn affects particle trajectories. The low capture rate of smaller particles is due to the particles' inability to cross the flow streamlines of neighboring cilia. Meanwhile, large particles have difficulty entering the sub-ciliary region once advected downstream, also resulting in low capture rates. The optimal range of particle sizes is enhanced when cilia beat asynchronously. These findings have potentially important implications on the design and use of biomimetic cilia in processes such as particle sorting in microfluidic devices.

  14. Technology Roadmap: Carbon Capture and Storage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-01

    As long as fossil fuels and carbon-intensive industries play dominant roles in our economies, carbon capture and storage (CCS) will remain a critical greenhouse gas reduction solution. This CCS roadmap aims at assisting governments and industry in integrating CCS in their emissions reduction strategies and in creating the conditions for scaled-up deployment of all three components of the CCS chain: CO2 capture, transport and storage. To get us onto the right pathway, this roadmap highlights seven key actions needed in the next seven years to create a solid foundation for deployment of CCS starting by 2020. IEA analysis shows that CCS is an integral part of any lowest-cost mitigation scenario where long-term global average temperature increases are limited to significantly less than 4 °C, particularly for 2 °C scenarios (2DS). In the 2DS, CCS is widely deployed in both power generation and industrial applications. The total CO2 capture and storage rate must grow from the tens of megatonnes of CO2 captured in 2013 to thousands of megatonnes of CO2 in 2050 in order to address the emissions reduction challenge. A total cumulative mass of approximately 120 GtCO2 would need to be captured and stored between 2015 and 2050, across all regions of the globe.

  15. Maintenance Therapy in IBD

    Science.gov (United States)

    ... Help Center Home > Resources > Maintenance Therapy Go Back Maintenance Therapy Email Print + Share The term "maintenance therapy" ... are referred to as "maintenance therapies." Why is Maintenance Therapy Needed in IBD? Both Crohn's disease and ...

  16. Neutron capture by hook or by crook

    Science.gov (United States)

    Mosby, Shea

    2016-03-01

    The neutron capture reaction is a topic of fundamental interest for both heavy element (A>60) nucleosynthesis and applications in such fields as nuclear energy and defense. The full suite of interesting isotopes ranges from stable nuclei to the most exotic, and it is not possible to directly measure all the relevant reaction rates. The DANCE instrument at Los Alamos provides direct access to the neutron capture reaction for stable and long-lived nuclei, while Apollo coupled to HELIOS at Argonne has been developed as an indirect probe for cases where a direct measurement is impossible. The basic techniques and their implications will be presented, and the status of ongoing experimental campaigns to address neutron capture in the A=60 and A=100 mass regions will be discussed.

  17. Muon capture rates within the projected QRPA

    CERN Document Server

    Santos, Danilo Sande; Krmpotić, Francisco; Dimarco, Alejandro J

    2012-01-01

    The conservation of the number of particles within the QRPA plays an important role in the evaluation muon capture rates in all light nuclei with A \\precsim 30 . The violation of the CVC by the Coulomb field in this mass region is of minor importance, but this effect could be quite relevant for medium and heavy nuclei studied previously. The extreme sensitivity of the muon capture rates on the 'pp' coupling strength in nuclei with large neutron excess when described within the QRPA is pointed out. We reckon that the comparison between theory and data for the inclusive muon capture is not a fully satisfactory test on the nuclear model that is used. The exclusive muon transitions are much more robust for such a purpose.

  18. Neutron transmission and capture of 241Am

    International Nuclear Information System (INIS)

    A set of neutron transmission and capture experiments based on the Time Of Flight (TOF) technique, were performed in order to determine the 241Am capture cross section in the energy range from 0.01 eV to 1 keV. The GELINA facility of the Institute for Reference Materials and Measurements (IRMM) served as the neutron source. A pair of C6D6 liquid scintillators was used to register the prompt gamma rays emerging from the americium sample, while a Li-glass detector was used in the transmission setup. Results from the capture and transmission data acquired are consistent with each other, but appear to be inconsistent with the evaluated data files. Resonance parameters have been derived for the data up to the energy of 100 eV. (authors)

  19. Selective gas capture via kinetic trapping.

    Science.gov (United States)

    Kundu, Joyjit; Pascal, Tod; Prendergast, David; Whitelam, Stephen

    2016-08-21

    Conventional approaches to the capture of CO2 by metal-organic frameworks focus on equilibrium conditions, and frameworks that contain little CO2 in equilibrium are often rejected as carbon-capture materials. Here we use a statistical mechanical model, parameterized by quantum mechanical data, to suggest that metal-organic frameworks can be used to separate CO2 from a typical flue gas mixture when used under nonequilibrium conditions. The origin of this selectivity is an emergent gas-separation mechanism that results from the acquisition by different gas types of different mobilities within a crowded framework. The resulting distribution of gas types within the framework is in general spatially and dynamically heterogeneous. Our results suggest that relaxing the requirement of equilibrium can substantially increase the parameter space of conditions and materials for which selective gas capture can be effected. PMID:27435033

  20. Quantifying protein diffusion and capture on filaments

    CERN Document Server

    Reithmann, Emanuel; Frey, Erwin

    2015-01-01

    The functional relevance of regulating proteins is often limited to specific binding sites such as the ends of microtubules or actin-filaments. A localization of proteins on these functional sites is of great importance. We present a quantitative theory for a diffusion and capture process, where proteins diffuse on a filament and stop diffusing when reaching the filament's end. It is found that end-association after one-dimensional diffusion is the main source for tip-localization of such proteins. As a consequence, diffusion and capture is highly efficient in enhancing the reaction velocity of enzymatic reactions, where proteins and filament ends are to each other as enzyme and substrate. We show that the reaction velocity can effectively be described within a Michaelis-Menten framework. Together one-dimensional diffusion and capture beats the (three-dimensional) Smoluchowski diffusion limit for the rate of protein association to filament ends.

  1. Electron capture in carbon dwarf supernovae

    Science.gov (United States)

    Mazurek, T. J.; Truran, J. W.; Cameron, A. G. W.

    1974-01-01

    The rates of electron capture on heavier elements under the extreme conditions predicted for dwarf star supernovae have been computed, incorporating modifications that seem to be indicated by present experimental results. An estimate of the maximum possible value of such rates is also given. The distribution of nuclei in nuclear statistical equilibrium has been calculated for the range of expected supernovae conditions, including the effects of the temperature dependence of nuclear partition functions. These nuclide abundance distributions are then used to compute nuclear equilibrium thermodynamic properties. The effects of the electron capture on such equilibrium matter are discussed. In the context of the 'carbon detonation' supernova model, the dwarf central density required to ensure core collapse to a neutron star configuration is found to be slightly higher than that obtained by Bruenn (1972) with the electron capture rates of Hansen (1966).-

  2. Rebuild of Capture Cavity 1 at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Harms, E. [Fermilab; Arkan, T. [Fermilab; Borissov, E. [Fermilab; Dhanaraj, N. [Fermilab; Hocker, A. [Fermilab; Orlov, Y. [Fermilab; Peterson, T. [Fermilab; Premo, K. [Fermilab

    2014-01-01

    The front end of the proposed Advanced Superconducting Test Accelerator at Fermilab employs two single cavity cryomodules, known as 'Capture Cavity 1' and 'Capture Cavity 2', for the first stage of acceleration. Capture Cavity 1 was previously used as the accelerating structure for the A0 Photoinjector to a peak energy of ~14 MeV. In its new location a gradient of ~25 MV/m is required. This has necessitated a major rebuild of the cryomodule including replacement of the cavity with a higher gradient one. Retrofitting the cavity and making upgrades to the module required significant redesign. The design choices and their rationale, summary of the rebuild, and early test results are presented.

  3. Selective gas capture via kinetic trapping

    CERN Document Server

    Kundu, Joyjit; Prendergast, David; Whitelam, Stephen

    2016-01-01

    Conventional approaches to the capture of CO_2 by metal-organic frameworks focus on equilibrium conditions, and frameworks that contain little CO_2 in equilibrium are often rejected as carbon-capture materials. Here we use a statistical mechanical model, parameterized by quantum mechanical data, to suggest that metal-organic frameworks can be used to separate CO_2 from a typical flue gas mixture when used under {\\em nonequilibrium} conditions. The origin of this selectivity is an emergent gas-separation mechanism that results from the acquisition by different gas types of different mobilities within a crowded framework. The resulting distribution of gas types within the framework is in general spatially and dynamically heterogeneous. Our results suggest that relaxing the requirement of equilibrium can substantially increase the parameter space of conditions and materials for which selective gas capture can be effected.

  4. Capturing intraoperative deformations: research experience at Brigham and Women's Hospital.

    Science.gov (United States)

    Warfield, Simon K; Haker, Steven J; Talos, Ion-Florin; Kemper, Corey A; Weisenfeld, Neil; Mewes, Andrea U J; Goldberg-Zimring, Daniel; Zou, Kelly H; Westin, Carl-Fredrik; Wells, William M; Tempany, Clare M C; Golby, Alexandra; Black, Peter M; Jolesz, Ferenc A; Kikinis, Ron

    2005-04-01

    During neurosurgical procedures the objective of the neurosurgeon is to achieve the resection of as much diseased tissue as possible while achieving the preservation of healthy brain tissue. The restricted capacity of the conventional operating room to enable the surgeon to visualize critical healthy brain structures and tumor margin has lead, over the past decade, to the development of sophisticated intraoperative imaging techniques to enhance visualization. However, both rigid motion due to patient placement and nonrigid deformations occurring as a consequence of the surgical intervention disrupt the correspondence between preoperative data used to plan surgery and the intraoperative configuration of the patient's brain. Similar challenges are faced in other interventional therapies, such as in cryoablation of the liver, or biopsy of the prostate. We have developed algorithms to model the motion of key anatomical structures and system implementations that enable us to estimate the deformation of the critical anatomy from sequences of volumetric images and to prepare updated fused visualizations of preoperative and intraoperative images at a rate compatible with surgical decision making. This paper reviews the experience at Brigham and Women's Hospital through the process of developing and applying novel algorithms for capturing intraoperative deformations in support of image guided therapy. PMID:15721230

  5. Thermal Propulsion Capture System Heat Exchanger Design

    Science.gov (United States)

    Richard, Evan M.

    2016-01-01

    One of the biggest challenges of manned spaceflight beyond low earth orbit and the moon is harmful radiation that astronauts would be exposed to on their long journey to Mars and further destinations. Using nuclear energy has the potential to be a more effective means of propulsion compared to traditional chemical engines (higher specific impulse). An upper stage nuclear engine would allow astronauts to reach their destination faster and more fuel efficiently. Testing these engines poses engineering challenges due to the need to totally capture the engine exhaust. The Thermal Propulsion Capture System is a concept for cost effectively and safely testing Nuclear Thermal Engines. Nominally, hydrogen exhausted from the engine is not radioactive, but is treated as such in case of fuel element failure. The Thermal Propulsion Capture System involves injecting liquid oxygen to convert the hydrogen exhaust into steam. The steam is then cooled and condensed into liquid water to allow for storage. The Thermal Propulsion Capture System concept for ground testing of a nuclear powered engine involves capturing the engine exhaust to be cooled and condensed before being stored. The hydrogen exhaust is injected with liquid oxygen and burned to form steam. That steam must be cooled to saturation temperatures before being condensed into liquid water. A crossflow heat exchanger using water as a working fluid will be designed to accomplish this goal. Design a cross flow heat exchanger for the Thermal Propulsion Capture System testing which: Eliminates the need for water injection cooling, Cools steam from 5800 F to saturation temperature, and Is efficient and minimizes water requirement.

  6. Optimized Affinity Capture of Yeast Protein Complexes.

    Science.gov (United States)

    LaCava, John; Fernandez-Martinez, Javier; Hakhverdyan, Zhanna; Rout, Michael P

    2016-01-01

    Here, we describe an affinity isolation protocol. It uses cryomilled yeast cell powder for producing cell extracts and antibody-conjugated paramagnetic beads for affinity capture. Guidelines for determining the optimal extraction solvent composition are provided. Captured proteins are eluted in a denaturing solvent (sodium dodecyl sulfate polyacrylamide gel electrophoresis sample buffer) for gel-based proteomic analyses. Although the procedures can be modified to use other sources of cell extract and other forms of affinity media, to date we have consistently obtained the best results with the method presented. PMID:27371596

  7. Protein Complex Purification by Affinity Capture.

    Science.gov (United States)

    LaCava, John; Fernandez-Martinez, Javier; Hakhverdyan, Zhanna; Rout, Michael P

    2016-01-01

    Affinity capture has become a powerful technique for consistently purifying endogenous protein complexes, facilitating biochemical and biophysical assays on otherwise inaccessible biological assemblies, and enabling broader interactomic exploration. For this procedure, cells are broken and their contents separated and extracted into a solvent, permitting access to target macromolecular complexes thus released in solution. The complexes are specifically enriched from the extract onto a solid medium coupled with an affinity reagent-usually an antibody-that recognizes the target either directly or through an appended affinity tag, allowing subsequent characterization of the complex. Here, we discuss approaches and considerations for purifying endogenous yeast protein complexes by affinity capture. PMID:27371601

  8. Systematic muon capture rates in PQRPA

    Energy Technology Data Exchange (ETDEWEB)

    Samana, A. R. [Departamento de Ciências Exatas e Tecnológicas, UESC-Br (Brazil); Sande, D. [Instituto de Geociências, UFBA-Br (Brazil); Krmpotić, F. [Instituto de Física La Plata, CONICET-Ar and Fac. de Cs. Astronómicas y Geofísicas, UNLP-Ar (Argentina)

    2015-05-15

    In this work we performed a systematic study of the inclusive muon capture rates for several nuclei with A < 60 using the Projected Random Quasi-particle Phase Approximation (PQRPA) as nuclear model, because it is the only RPA model that treats the Pauli Principle correctly. We reckon that the comparison between theory and data for the inclusive muon capture is not a fully satisfactory test on the nuclear model that is used. The exclusive muon transitions are more robust for such a purpose.

  9. Family therapy

    Directory of Open Access Journals (Sweden)

    Shaikh Altamash

    2013-01-01

    Full Text Available Another major force not letting us succeed in the treatment of diabetes remains right inside the patients home, their family members. Hence, it is important to know the perception of the close family members about this simple and strong tool in diabetes, ′insulin′. The drug is nearing its century, it has not fully being accepted gracefully even in todays electronic savvy society. So, we need to strongly discover the reason for its non-acceptance, while trials are out inventing new drugs. One vital thing that can change this attitude is increasing the understanding of this drug, insulin in depth to close people around the patient, the ′family′. Underestimating family′s perception about disease and treatment for diabetes is detrimental to both diseased and the doctor. This consists of a biopsychosocial model; biological, psychological and social factors. Family forms the most important part of it. The strategies in family therapy include psychodynamic, structural, strategic, and cognitive-behavioral component. Diabetes has and will continue to rise, so will be the treatment options. From the clinicians side its to fix fasting first but from patients its fix family first. Family therapy demonstrates the importance of insulin initiation and maintenance in insulin naive patients, and continuation for others. The specific needs of such patients and their impact on family life are met with family therapy. Who needs family therapy? Benefits of family therapy and a case based approach is covered.

  10. Boron neutron capture irradiation: setting up a clinical programme in Nice; Irradiation par capture de neutrons: mise en place d`un programme clinique a Nice

    Energy Technology Data Exchange (ETDEWEB)

    Pignol, J.P.; Chauvel, P.; Courdi, A.; Iborra-Brassart, N.; Frenay, M.; Herault, J.; Bensadoun, R.J.; Milano, G.; Demard, F. [Centre de Lutte Contre le Cancer Antoine Lacassagne, 06 - Nice (France); Paquis, P.; Lonjon, M.; Lebrun-Frenay, C.; Grellier, P.; Chatel, M. [Hopital Pasteur, 06 - Nice (France); Nepveu, F.; Patau, J.P. [Toulouse-3 Univ., 31 (France); Breteau, N. [Hopital de la Source, 45 - Orleans (France)

    1996-12-31

    Neutron capture irradiation aims to selectively destroy tumor tumor cell using {sup 10}B(n,{alpha}){sup 7}Li nuclear reactions produced within themselves. Following the capture reaction, an {alpha} particle and a, {sup 7}Li ion are emitted. Carrying an energy of 2.79 MeV, they destroy all molecular structures along their path close to 10 {mu}m. These captures, used exclusively with a `slow` neutron irradiation, provide a neutron capture therapy (BNCT). If they are used in addition to a fast neutron beam irradiation, they provide a neutron capture potentiation (NCP). The Centre Antoine-Lacassagne in Nice is actively involved in the European Demonstration project for BNCT of grade IV glioblastomas (GBM) after surgical excision and BSH administration. Taking into account the preliminary results obtained in Japan, work on an `epithermal` neutron target compatible with various cyclotron beams is in progress to facilitate further developments of this technique. For NCP, thermalized neutron yield has been measured in phantoms irradiated in the fast neutron beam of the biomedical cyclotron in Nice. A thermal peak appears after 5 cm depth in the tissues, delayed after the fast neutron peak at 1.8 cm depth. Thus, a physical overdosage of 10 % may be obtained if 100 ppm of {sup 10}B are assumed in the tissues. Our results using CAL 58 GBM cell line demonstrate a dose modification factor (DMF) of 1.19 when 100 ppm of boric acid are added to the growth medium. Thus for the particles, issued from neutron capture, a biological efficiency at least twice that of fast neutrons can be derived. These results, compared with historical data on fast neutron irradiation of glioblastoma, suggest that a therapeutic window may be obtained for GBM. (author). 26 refs.

  11. Sequential Treatment of Severe Postmenopausal Osteoporosis Following Teriparatide: Final Results of the Randomized, Controlled European Study of Forsteo (EUROFORS): Trial registration: clinicaltrials.gov identifier NCT00191425 (Trial registration date: 12 September 2005)

    DEFF Research Database (Denmark)

    Eastell, Richard; Nickelsen, Thomas; Marin, Fernando;

    2009-01-01

    Abstract It is unclear which treatment should be given after stopping teriparatide therapy for severe osteoporosis. In a prospective, randomized, controlled, 2-yr study, we compared bone mineral density (BMD) effects and clinical safety of 3 follow-up treatments (anabolic with teriparatide...

  12. Art Therapy

    DEFF Research Database (Denmark)

    Skov, Vibeke; Pedersen, Inge Nygaard

    2014-01-01

    Abstract Based on a Jungian approach, this article will introduce an integrative model to therapeutic change using art therapy methods as practical tools, with the aim of improving quality of life and in the prevention of depression. In a research study involving six participants, painting, clay...... work and drumming were used together with imagination and personal dialogues linked to the artwork. These art therapy processes attempted to combine the participant’s experience of inner and outer reality. The effect of gaining more knowledge about their inner reality using dreams and symbols......, was that participants gained a new understanding about their personal life. In addition, some participants were able to continue to use art therapy experiences as selfdevelopmental tools after the research study terminated. Jung’s description of the interactive relationship between the two living parts of the psyche...

  13. Historic Methods for Capturing Magnetic Field Images

    Science.gov (United States)

    Kwan, Alistair

    2016-01-01

    I investigated two late 19th-century methods for capturing magnetic field images from iron filings for historical insight into the pedagogy of hands-on physics education methods, and to flesh out teaching and learning practicalities tacit in the historical record. Both methods offer opportunities for close sensory engagement in data-collection…

  14. Capture technologies: Improvements and promising developments

    NARCIS (Netherlands)

    Blomen, E.; Hendriks, C.; Neele, F.

    2009-01-01

    In this status report we want to provide a comprehensive overview of the current status and promising technologies of CO2 capture by means of a literature review, in-house knowledge and interviews. We describe the technology, bottlenecks towards implementation and potential use. The results will be

  15. CAPTURING CO2 WITH MGO AEROGELS

    Science.gov (United States)

    CO2 capture from flue gas requires that the adsorbent be active at relatively low CO2 concentrations (3 – 13 vol%), high temperatures (~ 250ºC), and in the presence of many other gas species. These conditions will be simulated in the student designed reactor. The...

  16. Analysis of capture-recapture data

    CERN Document Server

    McCrea, Rachel S

    2014-01-01

    An important first step in studying the demography of wild animals is to identify the animals uniquely through applying markings, such as rings, tags, and bands. Once the animals are encountered again, researchers can study different forms of capture-recapture data to estimate features, such as the mortality and size of the populations. Capture-recapture methods are also used in other areas, including epidemiology and sociology.With an emphasis on ecology, Analysis of Capture-Recapture Data covers many modern developments of capture-recapture and related models and methods and places them in the historical context of research from the past 100 years. The book presents both classical and Bayesian methods.A range of real data sets motivates and illustrates the material and many examples illustrate biometry and applied statistics at work. In particular, the authors demonstrate several of the modeling approaches using one substantial data set from a population of great cormorants. The book also discusses which co...

  17. Salmonella capture using orbiting magnetic microbeads

    Science.gov (United States)

    Owen, Drew; Ballard, Matthew; Mills, Zachary; Hanasoge, Srinivas; Hesketh, Peter; Alexeev, Alexander

    2014-11-01

    Using three-dimensional simulations and experiments, we examine capture of salmonella from a complex fluid sample flowing through a microfluidic channel. Capture is performed using orbiting magnetic microbeads, which can easily be extracted from the system for analysis after salmonella capture. Numerical simulations are used to model the dynamics of the system, which consists of a microchannel filled with a viscous fluid, model salmonella, magnetic microbeads and a series of angled parallel ridges lining the top of the microchannel. Simulations provide a statistical measure of the ability of the system to capture target salmonella. Our modeling findings guide the design of a lab-on-a-chip experimental device to be used for the detection of salmonella from complex food samples, allowing for the detection of the bacteria at the food source and preventing the consumption of contaminated food. Such a device can be used as a generic platform for the detection of a variety of biomaterials from complex fluids. This work is supported by a grant from the United States Department of Agriculture.

  18. Capture and fission with DANCE and NEUANCE

    Energy Technology Data Exchange (ETDEWEB)

    Jandel, M.; Baramsai, B.; Bond, E.; Rusev, G.; Walker, C.; Bredeweg, T.A.; Chadwick, M.B.; Couture, A.; Fowler, M.M.; Hayes, A.; Kawano, T.; Mosby, S.; Stetcu, I.; Taddeucci, T.N.; Talou, P.; Ullmann, J.L.; Vieira, D.J.; Wilhelmy, J.B. [Los Alamos National Laboratory, Los Alamos, New Mexico (United States)

    2015-12-15

    A summary of the current and future experimental program at DANCE is presented. Measurements of neutron capture cross sections are planned for many actinide isotopes with the goal to reduce the present uncertainties in nuclear data libraries. Detailed studies of capture gamma rays in the neutron resonance region will be performed in order to derive correlated data on the de-excitation of the compound nucleus. New approaches on how to remove the DANCE detector response from experimental data and retain the correlations between the cascade gamma rays are presented. Studies on {sup 235}U are focused on quantifying the population of short-lived isomeric states in {sup 236}U after neutron capture. For this purpose, a new neutron detector array NEUANCE is under construction. It will be installed in the central cavity of the DANCE array and enable the highly efficient tagging of fission and capture events. In addition, developments of fission fragment detectors are also underway to expand DANCE capabilities to measurements of fully correlated data on fission observables. (orig.)

  19. Capture and fission with DANCE and NEUANCE

    Science.gov (United States)

    Jandel, M.; Baramsai, B.; Bond, E.; Rusev, G.; Walker, C.; Bredeweg, T. A.; Chadwick, M. B.; Couture, A.; Fowler, M. M.; Hayes, A.; Kawano, T.; Mosby, S.; Stetcu, I.; Taddeucci, T. N.; Talou, P.; Ullmann, J. L.; Vieira, D. J.; Wilhelmy, J. B.

    2015-12-01

    A summary of the current and future experimental program at DANCE is presented. Measurements of neutron capture cross sections are planned for many actinide isotopes with the goal to reduce the present uncertainties in nuclear data libraries. Detailed studies of capture gamma rays in the neutron resonance region will be performed in order to derive correlated data on the de-excitation of the compound nucleus. New approaches on how to remove the DANCE detector response from experimental data and retain the correlations between the cascade gamma rays are presented. Studies on 235U are focused on quantifying the population of short-lived isomeric states in 236U after neutron capture. For this purpose, a new neutron detector array NEUANCE is under construction. It will be installed in the central cavity of the DANCE array and enable the highly efficient tagging of fission and capture events. In addition, developments of fission fragment detectors are also underway to expand DANCE capabilities to measurements of fully correlated data on fission observables.

  20. Capture and fission with DANCE and NEUANCE

    International Nuclear Information System (INIS)

    A summary of the current and future experimental program at DANCE is presented. Measurements of neutron capture cross sections are planned for many actinide isotopes with the goal to reduce the present uncertainties in nuclear data libraries. Detailed studies of capture gamma rays in the neutron resonance region will be performed in order to derive correlated data on the de-excitation of the compound nucleus. New approaches on how to remove the DANCE detector response from experimental data and retain the correlations between the cascade gamma rays are presented. Studies on 235U are focused on quantifying the population of short-lived isomeric states in 236U after neutron capture. For this purpose, a new neutron detector array NEUANCE is under construction. It will be installed in the central cavity of the DANCE array and enable the highly efficient tagging of fission and capture events. In addition, developments of fission fragment detectors are also underway to expand DANCE capabilities to measurements of fully correlated data on fission observables. (orig.)

  1. Influence of attentional capture on oculomotor control

    NARCIS (Netherlands)

    Theeuwes, J.; Kramer, A.F.; Hahn, S.

    1999-01-01

    Previous research has shown that when searching for a color singleton. top-down control cannot prevent attentional capture by an abrupt visual onset. The present research addressed whether a task-irrelevant abrupt onset would affect eye movement behavior when searching for a color singleton. Results

  2. Incremental learning for automated knowledge capture.

    Energy Technology Data Exchange (ETDEWEB)

    Benz, Zachary O.; Basilico, Justin Derrick; Davis, Warren Leon,; Dixon, Kevin R.; Jones, Brian S.; Martin, Nathaniel; Wendt, Jeremy Daniel

    2013-12-01

    People responding to high-consequence national-security situations need tools to help them make the right decision quickly. The dynamic, time-critical, and ever-changing nature of these situations, especially those involving an adversary, require models of decision support that can dynamically react as a situation unfolds and changes. Automated knowledge capture is a key part of creating individualized models of decision making in many situations because it has been demonstrated as a very robust way to populate computational models of cognition. However, existing automated knowledge capture techniques only populate a knowledge model with data prior to its use, after which the knowledge model is static and unchanging. In contrast, humans, including our national-security adversaries, continually learn, adapt, and create new knowledge as they make decisions and witness their effect. This artificial dichotomy between creation and use exists because the majority of automated knowledge capture techniques are based on traditional batch machine-learning and statistical algorithms. These algorithms are primarily designed to optimize the accuracy of their predictions and only secondarily, if at all, concerned with issues such as speed, memory use, or ability to be incrementally updated. Thus, when new data arrives, batch algorithms used for automated knowledge capture currently require significant recomputation, frequently from scratch, which makes them ill suited for use in dynamic, timecritical, high-consequence decision making environments. In this work we seek to explore and expand upon the capabilities of dynamic, incremental models that can adapt to an ever-changing feature space.

  3. CO2 capture, transport, storage and utilisation

    NARCIS (Netherlands)

    Brouwer, J.H.

    2013-01-01

    Reducing CO2 emissions requires an integrated CO2 management approach. The dependency between the different industry sectors is higher than commonly acknowledged and covers all areas; capture, transport, storage and utilisation. TNO is one of Europe’s largest independent research organisations and p

  4. Water surface capturing by image processing

    Science.gov (United States)

    An alternative means of measuring the water surface interface during laboratory experiments is processing a series of sequentially captured images. Image processing can provide a continuous, non-intrusive record of the water surface profile whose accuracy is not dependent on water depth. More trad...

  5. CO2 Capture for Cement Technology

    DEFF Research Database (Denmark)

    Pathi, Sharat Kumar

    % of the inlet CO2 was captured by highly deactivated limestone, which had a maximum CO2 capture capacity of 11.5%, with an inlet Ca/C ratio of 13. So, the performance of the carbonator can be defined by the inlet Ca/C ratio, which can be estimated if the maximum capture capacity of limestone is known...... and the main parameter that controls the performance of the carbonator, a process model integrating the carbonate looping process with the cement pyro-process was simulated. The process simulation results indicate that the CO2 emission was only 0.07 kg/ kg cl, with an energy penalty of 2 MJ/kg CO2 captured...... ppmvin 1960 to 390 ppmv in 2012, probably due to human activity. A lot of research is being carried out forreducing CO2emissions from large stationary sources. Ofwhich, the carbonate looping process is anew process and has the potential to reduce CO2emissions with lower energy penalties. Most of thework...

  6. Capturing phosphates with iron enhanced sand filtration.

    Science.gov (United States)

    Erickson, Andrew J; Gulliver, John S; Weiss, Peter T

    2012-06-01

    Most treatment practices for urban runoff capture pollutants such as phosphorus by either settling or filtration while dissolved phosphorus, typically as phosphates, is untreated. Dissolved phosphorus, however, represents an average 45% of total phosphorus in stormwater runoff and can be more than 95%. In this study, a new stormwater treatment technology to capture phosphate, called the Minnesota Filter, is introduced. The filter comprises iron filings mixed with sand and is tested for phosphate removal from synthetic stormwater. Results indicate that sand mixed with 5% iron filings captures an average of 88% phosphate for at least 200 m of treated depth, which is significantly greater than a sand filter without iron filings. Neither incorporation of iron filings into a sand filter nor capture of phosphates onto iron filings in column experiments had a significant effect on the hydraulic conductivity of the filter at mixtures of 5% or less iron by weight. Field applications with up to 10.7% iron were operated over 1 year without detrimental effects upon hydraulic conductivity. A model is applied and fit to column studies to predict the field performance of iron-enhanced sand filters. The model predictions are verified through the predicted performance of the filters in removing phosphates in field applications. Practical applications of the technology, both existing and proposed, are presented so stormwater managers can begin implementation.

  7. Historic Methods for Capturing Magnetic Field Images

    Science.gov (United States)

    Kwan, Alistair

    2016-03-01

    I investigated two late 19th-century methods for capturing magnetic field images from iron filings for historical insight into the pedagogy of hands-on physics education methods, and to flesh out teaching and learning practicalities tacit in the historical record. Both methods offer opportunities for close sensory engagement in data-collection processes.

  8. One- and two-phonon capture processes in quantum dots

    DEFF Research Database (Denmark)

    Magnúsdóttir, Ingibjörg; Uskov, Alexander; Bischoff, Svend;

    2002-01-01

    Multiphonon capture processes are investigated theoretically and found to contribute efficiently to the carrier injection into quantum dots. It is shown that two-phonon capture contributes where single-phonon capture is energetically inhibited and can lead to electron capture times of a few...

  9. Annual Report: Carbon Capture (30 September 2012)

    Energy Technology Data Exchange (ETDEWEB)

    Luebke, David; Morreale, Bryan; Richards, George; Syamlal, Madhava

    2014-04-16

    Capture of carbon dioxide (CO{sub 2}) is a critical component in reducing greenhouse gas emissions from fossil fuel-based processes. The Carbon Capture research to be performed is aimed at accelerating the development of efficient, cost-effective technologies which meet the post-combustion programmatic goal of capture of 90% of the CO{sub 2} produced from an existing coal-fired power plant with less than a 35% increase in the cost of electricity (COE), and the pre-combustion goal of 90% CO{sub 2} capture with less than a 10% increase in COE. The specific objective of this work is to develop innovative materials and approaches for the economic and efficient capture of CO{sub 2} from coal-based processes, and ultimately assess the performance of promising technologies at conditions representative of field application (i.e., slip stream evaluation). The Carbon Capture research includes seven core technical research areas: post-combustion solvents, sorbents, and membranes; pre-combustion solvents, sorbents, and membranes; and oxygen (O{sub 2}) production. The goal of each of these tasks is to develop advanced materials and processes that are able to reduce the energy penalty and cost of CO{sub 2} (or O{sub 2}) separation over conventional technologies. In the first year of development, materials will be examined by molecular modeling, and then synthesized and experimentally characterized at lab scale. In the second year, they will be tested further under ideal conditions. In the third year, they will be tested under realistic conditions. The most promising materials will be tested at the National Carbon Capture Center (NCCC) using actual flue or fuel gas. Systems analyses will be used to determine whether or not materials developed are likely to meet the Department of Energy (DOE) COE targets. Materials which perform well and appear likely to improve in performance will be licensed for further development outside of the National Energy Technology Laboratory (NETL

  10. Properties of Earth's temporarily-captured flybys

    Science.gov (United States)

    Fedorets, Grigori; Granvik, Mikael

    2014-11-01

    In addition to the Moon, a population of small temporarily-captured NEOs is predicted to orbit the Earth. The definition of a natural Earth satellite is that it is on an elliptic geocentric orbit within 0.03 au from the Earth. The population is further divided into temporarily-captured orbiters (TCOs, or minimoons, making at least one full revolution around the Earth in a coordinate system co-rotating with the Sun) and temporarily-captured flybys (TCFs) which fail to make a full revolution, but are temporarily on an elliptic orbit around the Earth. Only one minimoon has been discovered to date, but it is expected that next generation surveys will be able to detect these objects regularly.Granvik et al. (2012) performed an extensive analysis of the behaviour of these temporarily-captured objects. One of the main results was that at any given moment there is at least one 1-meter-diameter minimoon in orbit around the Earth. However, the results of Granvik et al. (2012) raised questions considering the NES population such as the bimodality of the capture duration distribution and a distinctive lack of test particles within Earth's Hill sphere, which requires investigating the statistical properties also of the TCF population.In this work we confirm the population characteristics for minimoons described by Granvik et al. (2012), and extend the analysis to TCFs. For the calculations we use a Bulirsch-Stoer integrator implemented in the OpenOrb software package (Granvik et al. 2009). We study, e.g., the capture statistics, residence-time distributions, and steady-state properties of TCFs. Our preliminary results indicate that TCFs may be suitable targets for asteroid-redirect missions. More detailed knowledge of the TCF population will also improve our understanding of the link between temporarily-captured objects and NEOs in general.References: Granvik et al. (2009) MPS 44(12), 1853-1861; Granvik et al. (2012) Icarus 218, 262-277.

  11. Truth therapy/lie therapy.

    Science.gov (United States)

    Langs, R

    In this paper an attempt is made to conceptualize a basic dimension of various psychotherapeutic treatment modalities, especially psychoanalysis and psychoanalytically oriented psychotherapy. The central variable under consideration is the extent to which each endeavors to approach the truth within both patient and therapist as it exists dynamically in terms of their spiraling unconscious communicative interaction. That treatment modality which takes into account every possible dimension of such truths is termed truth therapy. Treatment modalities that make no attempt to arrive at these truths or that deliberately or inadvertently falsify their nature are termed lie or barrier therapies. Extensive consideration is given to truth therapy and the truth system on which it is based. The basis for the need for lie therapies is explored, and lie systems, which may arise from either patient or therapist, or both, are identified. A classification of common types of lie patients and lie therapists (and their main techniques) is offered. The implications of this delineation for our understanding of the dynamic therapies are discussed, and a number of new clinical issues arising from this perspective are addressed.

  12. What Is Music Therapy?

    Science.gov (United States)

    American Music Therapy Association Home Contact News Help/FAQ Members Only Login About Music Therapy & AMTA What is Music Therapy? Definition and Quotes ... is Music Therapy? Print Email Share What is Music Therapy What is Music Therapy? Music Therapy is the ...

  13. Pet Therapy.

    Science.gov (United States)

    Kavanagh, Kim

    1994-01-01

    This resource guide presents information on a variety of ways that animals can be used as a therapeutic modality with people having disabilities. Aspects addressed include: pet ownership and selection criteria; dogs (including service dogs, hearing/signal dogs, seeing leader dogs, and social/specialty dogs); horseriding for both therapy and fun;…

  14. Continuum capture in the three-body problem

    International Nuclear Information System (INIS)

    The three-body problem, especially the problem of electron capture to the continuum in heavy particle collisions is reviewed. Major topics covered include: second born-induced asymmetry in electron capture to the continuum; historical context, links to other tests of atomic scattering theory; experiments characterizing the velocity distribution of ECC electrons; other atomic physics tests of high velocity Born expansions; atom capture; capture by positrons; and pion capture to the continuum

  15. Mindfulness-based cognitive therapy for multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Hauge, Christian R; Bonde, Jens Peter E; Rasmussen, Alice;

    2012-01-01

    no evidence-based treatments for MCS. Nevertheless, there is a substantial need for a treatment, because the condition can be severely disabling and can greatly reduce the quality of life (QOL) for those affected.In this study, we aim to assess the effects of a mindfulness-based cognitive therapy (MBCT.......5 hour sessions, and 45 minutes of mindfulness home practice 6 days each week. Participants will be asked to complete questionnaires at baseline, post-treatment, and at 6 and 12 months' follow-up. Based on sample size estimation, 82 participants will be randomized to either the MBCT intervention...... is mediated by level of mindfulness, perceived stress, and rumination. DISCUSSION: This trial will provide important information on the effects of MBCT on MCS.Trials registrationClinical trials identifier NCT01240395....

  16. Real-life use of budesonide/formoterol in clinical practice: a 12-month follow-up assessment in a multi-national study of asthma patients established on single-inhaler maintenance and reliever therapy

    OpenAIRE

    Ställberg, Björn; Naya, Ian; Ekelund, Jan; Eckerwall, Göran

    2015-01-01

    Objective: The efficacy and safety of budesonide/formoterol maintenance and reliever therapy (MRT) has been demonstrated in phase III clinical studies, but limited data are available in a real-life setting. We examined the pattern of maintenance and as-needed inhaler use in routine clinical practice among patients with asthma receiving budesonide/formoterol MRT (NCT00505388). Methods: This 12-month European observational study enrolled patients prescribed budesonide/formoterol MRT and grouped...

  17. Anecdotal therapies.

    Science.gov (United States)

    Millikan, L E

    1999-01-01

    Traditionally, many advances in medicine have been serendipitous. Are serendipitous and anecdotal synonymous? Many of our materia medica today relate to initial probes and anecdotal reports that matured to full investigation and therapeutic indications. The recent situation regarding Skin Cap is one that highlights the downside of this scenario. Several drugs in the US continue usage largely related to anecdotal indications, and anecdotal extension of legend indications is a standard for American Dermatology. The situation with systemic drugs, such as Trental, zinc preparations, imidazoles for extended indications, lysine and melatonin, all will be discussed. Topical preparations such as skin cap, cantharone, Vioform, all also are included in this category. It is important to place this topic in perspective in regards to geographic variation and therapeutic need. Many diseases lacking specific therapy are important targets for anecdotal therapy, and this will foster continued approaches in this area. The growing standardization of medicine and pharmaceutical regulation, threatens the anecdotal approach, but it provides still an important link to the future for some forms of therapy in diseases that are difficult to treat. Traditionally, the anecdote has been the first step in the therapeutic chain. Withering discovery of the benefits of the common fox glove in dropsy, was followed by many other anecdotes arriving via folk-medicine in the New World. This approach of utilizing folk medicine has now reached new heights, with very active searches by major pharmaceutical companies throughout the third world for remedies that may have potential. Couched with this is the history of anecdotal "snake-oil" remedies, that clearly had no benefit to anyone except the huckster marketing same. The excesses in this area of unproven and false therapies, led to the gradual organization of therapeutic trials and the Food and Drug Administration in the US as we know it today. The

  18. Hadron therapy

    International Nuclear Information System (INIS)

    Full text: Historically discoveries and technological advances in radiation and accelerator physics have been rapidly applied in the healing arts. X rays, discovered by Roentgen in 1895, and radioisotopes, discovered by Becquerel in 1896, were both applied to the treatment of cancer by the first year of the twentieth century. By the time that Chadwick discovered the neutron in 1932 radiotherapy was a well-established modality for the treatment of cancer. The potential use of neutrons in radiotherapy was immediately recognized by L.H. Gray (a recent Ph.D. graduate from the Cavendish laboratories in Cambridge). He built a neutron generator for radiobiology research at Mount Vernon Hospital in London, it's design was based on a similar device built at Cambridge by Mark Oliphant. In parallel with these developments Earnest Lawrence, in collaboration with his brother John Lawrence, a physician, were also studying the radiobiology of neutrons. They obtained some funding from the US National Cancer Institute to construct a 60'' cyclotron for neutron radiation therapy. These clinical trials, started in 1938, were the first application of heavy particles for cancer therapy. Immediately after the second World War advances in accelerator technology lead to the building of the first synchrocyclotrons, which produced proton beams with ranges approaching 30 cm in water. At the Harvard synchrocyclotron Robert R. Wilson realized that proton beams might have considerable advantages over other radiation beams in the treatment of deep-seated tumors. This advantage derives from the increase in stopping power at the end of the proton range, first observed by W.H.Bragg at the University of Adelaide; a phenomenon now known as the Bragg peak. Conventional X-ray beams are exponentially attenuated by matter and, hence, delivering large radiation doses to tumors at depth while not causing excessive damage to the overlying normal tissues can be problematical. The Bragg peak and the well

  19. Hybridization Capture Using Short PCR Products Enriches Small Genomes by Capturing Flanking Sequences (CapFlank)

    DEFF Research Database (Denmark)

    Tsangaras, Kyriakos; Wales, Nathan; Sicheritz-Pontén, Thomas;

    2014-01-01

    Solution hybridization capture methods utilize biotinylated oligonucleotides as baits to enrich homologous sequences from next generation sequencing (NGS) libraries. Coupled with NGS, the method generates kilo to gigabases of high confidence consensus targeted sequence. However, in many experiments...

  20. Electron capture by protons and deuterons

    International Nuclear Information System (INIS)

    Cross section measurements are reported for electron capture into the 3s state by 20-150 keV protons and deuterons incident on molecular hydrogen and deuterium. Conventional wisdom indicates that these cross sections should be nearly identical at equivalent velocities and researchers routinely use deuteron projectiles to extend proton excitation curves downward in velocity. This practice has been questioned on theoretical grounds and some investigators have reported consistent differences in cross sections for the two isotopes, however, nearly always within the experimental uncertainty of the measurements. The authors have made a systematic study of the 3s electron capture cross sections described above to check for isotopic effects. These cross sections are then compared to previous measurements reported in the literature

  1. Muon Capture on the Proton and Deuteron

    CERN Document Server

    Gray, Frederick

    2008-01-01

    By measuring the lifetime of the negative muon in pure protium (hydrogen-1), the MuCap experiment determines the rate of muon capture on the proton, from which the proton's pseudoscalar coupling g_p may be inferred. A precision of 15% for g_p has been published; this is a step along the way to a goal of 7%. This coupling can be calculated precisely from heavy baryon chiral perturbation theory and therefore permits a test of QCD's chiral symmetry. Meanwhile, the MuSun experiment is in its final design stage; it will measure the rate of muon capture on the deuteron using a similar technique. This process can be related through pionless effective field theory and chiral perturbation theory to other two-nucleon reactions of astrophysical interest, including proton-proton fusion and deuteron breakup.

  2. Gold nanoparticle capture within protein crystal scaffolds.

    Science.gov (United States)

    Kowalski, Ann E; Huber, Thaddaus R; Ni, Thomas W; Hartje, Luke F; Appel, Karina L; Yost, Jarad W; Ackerson, Christopher J; Snow, Christopher D

    2016-07-01

    DNA assemblies have been used to organize inorganic nanoparticles into 3D arrays, with emergent properties arising as a result of nanoparticle spacing and geometry. We report here the use of engineered protein crystals as an alternative approach to biologically mediated assembly of inorganic nanoparticles. The protein crystal's 13 nm diameter pores result in an 80% solvent content and display hexahistidine sequences on their interior. The hexahistidine sequence captures Au25(glutathione)∼17 (nitrilotriacetic acid)∼1 nanoclusters throughout a chemically crosslinked crystal via the coordination of Ni(ii) to both the cluster and the protein. Nanoparticle loading was validated by confocal microscopy and elemental analysis. The nanoparticles may be released from the crystal by exposure to EDTA, which chelates the Ni(ii) and breaks the specific protein/nanoparticle interaction. The integrity of the protein crystals after crosslinking and nanoparticle capture was confirmed by single crystal X-ray crystallography. PMID:27264210

  3. Book review: Spatial capture-recapture

    Science.gov (United States)

    Russell, Robin E.

    2014-01-01

    Understanding how animals use space is a vital aspect of conservation planning and wildlife management. Technological developments (e.g., increased computer power and desktop geographic information system [GIS] applications) are bringing the ability to analyze spatial data sets to the individual biologist. Therefore, it is not surprising that methodologies have been developed to incorporate space into capture-recapture models, which are some of the most fundamental models in the field of wildlife ecology. Spatial Capture-Recapture (hereafter SCR) is a timely and informative contribution that summarizes the history and motivation behind SCR models, in addition to providing details of the methodological framework that allows the reader to develop and customize SCR models to address their own ecological questions.

  4. Interactive animation of 4D performance capture.

    Science.gov (United States)

    Casas, Dan; Tejera, Margara; Guillemaut, Jean-Yves; Hilton, Adrian

    2013-05-01

    A 4D parametric motion graph representation is presented for interactive animation from actor performance capture in a multiple camera studio. The representation is based on a 4D model database of temporally aligned mesh sequence reconstructions for multiple motions. High-level movement controls such as speed and direction are achieved by blending multiple mesh sequences of related motions. A real-time mesh sequence blending approach is introduced, which combines the realistic deformation of previous nonlinear solutions with efficient online computation. Transitions between different parametric motion spaces are evaluated in real time based on surface shape and motion similarity. Four-dimensional parametric motion graphs allow real-time interactive character animation while preserving the natural dynamics of the captured performance.

  5. Electron capture cross sections for stellar nucleosynthesis

    CERN Document Server

    Giannaka, P G

    2015-01-01

    In the first stage of this work, we perform detailed calculations for the cross sections of the electron capture on nuclei under laboratory conditions. Towards this aim we exploit the advantages of a refined version of the proton-neutron quasi-particle random-phase approximation (pn-QRPA) and carry out state-by-state evaluations of the rates of exclusive processes that lead to any of the accessible transitions within the chosen model space. In the second stage of our present study, we translate the above mentioned $e^-$-capture cross sections to the stellar environment ones by inserting the temperature dependence through a Maxwell-Boltzmann distribution describing the stellar electron gas. As a concrete nuclear target we use the $^{66}Zn$ isotope, which belongs to the iron group nuclei and plays prominent role in stellar nucleosynthesis at core collapse supernovae environment.

  6. Briefing: Carbon capture and storage in Scotland

    OpenAIRE

    Haszeldine, R Stuart; Scott, Vivian; Littlecott, Chris

    2013-01-01

    With world-leading decarbonisation targets, a large and mature hydrocarbon sector, existing pipeline infrastructure and extensive opportunities for geological CO2 storage under the North Sea, Scotland is uniquely placed to deliver and benefit from carbon capture and storage (CCS). CCS has the potential to enable major Scottish emissions reductions towards the 2050 target – it can directly address over 50% of current total emissions from energy and industry. With world-leading decarbonisati...

  7. Impact detections of temporarily captured natural satellites

    Science.gov (United States)

    Clark, David; Spurný, Pavel; Wiegert, Paul; Brown, Peter G.; Borovicha, Jiri; Tagliaferri, Ed; Shrbeny, Lukas

    2016-10-01

    Temporarily Captured Orbiters (TCOs) are Near-Earth Objects (NEOs) which make a few orbits of Earth before returning to heliocentric orbits. Only one TCO has been observed to date, 2006 RH120, captured by Earth for one year before escaping. Detailed modeling predicts capture should occur from the NEO population predominantly through the Sun-Earth L1 and L2 points, with 1% of TCOs impacting Earth and approximately 0.1% of meteoroids being TCOs. Although thousands of meteoroid orbits have been measured, none until now have conclusively exhibited TCO behaviour, largely due to difficulties in measuring initial meteoroid speed with sufficient precision. We report on a precise meteor observation of January 13, 2014 by a new generation of all-sky fireball digital camera systems operated in the Czech Republic as part of the European Fireball Network, providing the lowest natural object entry speed observed in decades long monitoring by networks world-wide. Modeling atmospheric deceleration and fragmentation yields an initial mass of ~5 kg and diameter of 15 cm, with a maximum Earth-relative velocity just over 11.0 km/s. Spectral observations prove its natural origin. Back-integration across observational uncertainties yields a 92 - 98% probability of TCO behaviour, with close lunar dynamical interaction. The capture duration varies across observational uncertainties from 48 days to 5+ years. We also report on two low-speed impacts recorded by US Government sensors, and we examine Prairie Network event PN39078 from 1965 having an extremely low entry speed of 10.9 km/s. In these cases uncertainties in measurement and origin make TCO designation uncertain.

  8. Double electron capture searches in $^{74}$Se

    CERN Document Server

    Lehnert, B; Degering, D; Sommer, D; Wagner, L; Zuber, K

    2016-01-01

    A search for various double electron capture modes of $^{74}$Se has been performed using an ultralow background Ge-detector in the Felsenkeller laboratory, Germany. Especially for the potentially resonant transition into the 1204.2 keV excited state of $^{74}$Ge a lower half-life limit of $0.70\\cdot 10^{19}$ yr (90% credibility) has been obtained. Serious concerns are raised about the validity of obtained $^{74}$Se limits in some recent publications.

  9. Media Capture and Information Monopolization in Japan

    OpenAIRE

    Au, Pak Hung; Kawai, Keiichi

    2010-01-01

    In this paper, we investigate the unique institution of the Japanese press industry called kisha club system, which is deemed as the symbol of media capture by the government, and collusion in the media industry. By tracing through its history, we show how the institution has developed as a result of the government's attempt to control the media, and the media's incentive to use the alluring opportunity provided by the government to limit the rivalry within the industry. We find that the dist...

  10. Capture cavity II results at FNAL

    Energy Technology Data Exchange (ETDEWEB)

    Branlard, Julien; Chase, Brian; Cancelo, G.; Carcagno, R.; Edwards, H.; Fliller, R.; Hanna, B.; Harms, Elvan; Hocker, A.; Koeth, T.; Kucera, M.; /Fermilab

    2007-06-01

    As part of the research and development towards the International Linear Collider (ILC), several test facilities have been developed at Fermilab. This paper presents the latest Low Level RF (LLRF) results obtained with Capture Cavity II (CCII) at the ILC Test Accelerator (ILCTA) test facility. The main focus will be on controls and RF operations using the SIMCON based LLRF system developed in DESY [1]. Details about hardware upgrades and future work will be discussed.

  11. Gold nanoparticle capture within protein crystal scaffolds

    Science.gov (United States)

    Kowalski, Ann E.; Huber, Thaddaus R.; Ni, Thomas W.; Hartje, Luke F.; Appel, Karina L.; Yost, Jarad W.; Ackerson, Christopher J.; Snow, Christopher D.

    2016-06-01

    DNA assemblies have been used to organize inorganic nanoparticles into 3D arrays, with emergent properties arising as a result of nanoparticle spacing and geometry. We report here the use of engineered protein crystals as an alternative approach to biologically mediated assembly of inorganic nanoparticles. The protein crystal's 13 nm diameter pores result in an 80% solvent content and display hexahistidine sequences on their interior. The hexahistidine sequence captures Au25(glutathione)~17 (nitrilotriacetic acid)~1 nanoclusters throughout a chemically crosslinked crystal via the coordination of Ni(ii) to both the cluster and the protein. Nanoparticle loading was validated by confocal microscopy and elemental analysis. The nanoparticles may be released from the crystal by exposure to EDTA, which chelates the Ni(ii) and breaks the specific protein/nanoparticle interaction. The integrity of the protein crystals after crosslinking and nanoparticle capture was confirmed by single crystal X-ray crystallography.DNA assemblies have been used to organize inorganic nanoparticles into 3D arrays, with emergent properties arising as a result of nanoparticle spacing and geometry. We report here the use of engineered protein crystals as an alternative approach to biologically mediated assembly of inorganic nanoparticles. The protein crystal's 13 nm diameter pores result in an 80% solvent content and display hexahistidine sequences on their interior. The hexahistidine sequence captures Au25(glutathione)~17 (nitrilotriacetic acid)~1 nanoclusters throughout a chemically crosslinked crystal via the coordination of Ni(ii) to both the cluster and the protein. Nanoparticle loading was validated by confocal microscopy and elemental analysis. The nanoparticles may be released from the crystal by exposure to EDTA, which chelates the Ni(ii) and breaks the specific protein/nanoparticle interaction. The integrity of the protein crystals after crosslinking and nanoparticle capture was

  12. Neutron capture cross sections from Surrogate measurements

    OpenAIRE

    Scielzo N.D.; Dietrich F.S.; Escher J.E.

    2010-01-01

    The prospects for determining cross sections for compound-nuclear neutron-capture reactions from Surrogate measurements are investigated. Calculations as well as experimental results are presented that test the Weisskopf-Ewing approximation, which is employed in most analyses of Surrogate data. It is concluded that, in general, one has to go beyond this approximation in order to obtain (n,γ) cross sections of sufficient accuracy for most astrophysical and nuclear-energy applications.

  13. Neutron capture cross sections from Surrogate measurements

    Directory of Open Access Journals (Sweden)

    Scielzo N.D.

    2010-03-01

    Full Text Available The prospects for determining cross sections for compound-nuclear neutron-capture reactions from Surrogate measurements are investigated. Calculations as well as experimental results are presented that test the Weisskopf-Ewing approximation, which is employed in most analyses of Surrogate data. It is concluded that, in general, one has to go beyond this approximation in order to obtain (n,γ cross sections of sufficient accuracy for most astrophysical and nuclear-energy applications.

  14. Mars Atmospheric Capture and Gas Separation

    Science.gov (United States)

    Muscatello, Anthony; Santiago-Maldonado, Edgardo; Gibson, Tracy; Devor, Robert; Captain, James

    2011-01-01

    The Mars atmospheric capture and gas separation project is selecting, developing, and demonstrating techniques to capture and purify Martian atmospheric gases for their utilization for the production of hydrocarbons, oxygen, and water in ISRU systems. Trace gases will be required to be separated from Martian atmospheric gases to provide pure C02 to processing elements. In addition, other Martian gases, such as nitrogen and argon, occur in concentrations high enough to be useful as buffer gas and should be captured as welL To achieve these goals, highly efficient gas separation processes will be required. These gas separation techniques are also required across various areas within the ISRU project to support various consumable production processes. The development of innovative gas separation techniques will evaluate the current state-of-the-art for the gas separation required, with the objective to demonstrate and develop light-weight, low-power methods for gas separation. Gas separation requirements include, but are not limited to the selective separation of: (1) methane and water from un-reacted carbon oxides (C02- CO) and hydrogen typical of a Sabatier-type process, (2) carbon oxides and water from unreacted hydrogen from a Reverse Water-Gas Shift process, (3) carbon oxides from oxygen from a trash/waste processing reaction, and (4) helium from hydrogen or oxygen from a propellant scavenging process. Potential technologies for the separations include freezers, selective membranes, selective solvents, polymeric sorbents, zeolites, and new technologies. This paper and presentation will summarize the results of an extensive literature review and laboratory evaluations of candidate technologies for the capture and separation of C02 and other relevant gases.

  15. The CO2 capture and sequestration plan

    International Nuclear Information System (INIS)

    The CO2 capture and sequestration plan is officially one of the most relevant solution in the world control against the greenhouse gas releases. In spite of the multiplication of the pilot plans, this technology delays however to run up. At the moment, it is always the petroleum and natural gas industries, with the enhanced oil recovery process, which highlight this technology. But, without a modification of the support mechanisms, the chances of succeed of the sector could be compromised. (O.M.)

  16. Medication errors: capture and prevention by pharmacy

    OpenAIRE

    Tomlin, Mark

    2011-01-01

    Introduction This thesis looks at the pharmacist’s contribution to the capture of medication errors and preventing harm reaching patients. It has several components: an analysis of annual surveys of interventions made by pharmacists at a large teaching hospital, a re-coding of these surveys to see how many interventions were the result of prescribing errors, and an experiment in A&E where the pharmacist drafted the first prescription chart. Methods One-week surveys of pharmacist int...

  17. Carbon Capture and Storage: Realising the potential?

    OpenAIRE

    Ghaleigh, Navraj Singh; Haszeldine, Stuart; Rossati, David; Kern, Florian; Gross, Matt; Gross, Rob; Heptonstall, Phil; Jones, Felicity; Ascui, Francisco; Chalmers, Hannah; Gibbins, Jon; Markusson, Nils; Marsden, Wendy; Russell, Stewart; Winskel, Mark

    2012-01-01

    The aim of the research is to assess the technical, economic, financial and social uncertainties facing carbon capture and storage (CCS) technologies, and to analyse the potential role they could play in the UK power sector between now and 2030. CCS technologies are often highlighted as a crucial component of future low carbon energy systems – in the UK and internationally. However, it is unclear when these technologies will be technically proven at full scale, and whether their costs will be...

  18. Radiative Neutron Capture on Lithium-7

    OpenAIRE

    Rupak, Gautam; Renato, Higa

    2011-01-01

    The radiative neutron capture on lithium-7 is calculated model independently using a low energy halo effective field theory. The cross section is expressed in terms of scattering parameters directly related to the S-matrix element. The cross section depends on the poorly known p-wave effective range parameter r. This constitutes the leading order uncertainty in traditional model calculations. It is explicitly demonstrated by comparing with potential model calculations. A single parameter fit ...

  19. Carbon capture using wastes: A review

    OpenAIRE

    Gunning, Peter; Hills, Colin; Araizi, Paris; Maries , Alan; Wray, David

    2014-01-01

    Potential key strategies for the management of anthropogenic CO2 emissions include mineral carbonation and storage in oil wells and in the oceans. In Europe, a large-scale demonstration of carbon capture and storage (CCS) has recently been given the go-ahead, and the application of mineral carbonation technology (MCT) to serpentine and olive-type minerals. Although less controversial in its approach, MCT involves intensive pre-treatment of the mineral feedstock, and a consequent high sequestr...

  20. Capture Reactions with Halo Effective Field Theory

    Science.gov (United States)

    Higa, R.

    2015-12-01

    Loosely bound nuclei far from the stability region emerge as a quantum phenomenon with many universal properties. The connection between these properties and the underlying symmetries can be best explored with halo/cluster EFT, an effective field theory where the softness of the binding momentum and the hardness of the core(s) form the expansion parameter of a given perturbative approach. In the following I highlight a particular application where these ideas are being tested, namely capture reactions.