WorldWideScience

Sample records for capsule tests representing

  1. Perform Ultrasonic Testing on Cs Capsule Overpacks

    Energy Technology Data Exchange (ETDEWEB)

    DAVIS, S.J.

    2000-04-06

    This procedure provides a safe, uniform method for the performance of the ultrasonic weld inspection of the Cesium capsule overpacks. The inspection system will detect cracks, lack of fusion, and lack of penetration. This computer controlled automated system will perform the examination once the capsule overpack has been placed in the pool cell. Examination of the capsule overpacks will be in accordance with drawing H-283014, REV. 0 ,and a certified NDE examiner will perform the test procedure, provide analysis, and test documentation.

  2. The Thermal Hydraulic Test of SFR Irradiation Test Capsule

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Yong; Park, Sung Jae; Choo, Kee Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Irradiation test using a capsule has been performed for fuel or material performance test in the test reactor. Irradiation capsule for the HANARO reactor must satisfy the hydraulic conditions and structural integrity from a out-pile test. Items of a out-pile test are pressure drop, flow-induced vibration test and endurance test. The results of test must show that a test capsule satisfy the HANARO operational requirement with sufficient margin. This paper describes the devices of thermal hydraulic test and the results of SFR test capsule

  3. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  4. Research on Technology of Filling Sodium into Fuel Test Capsules

    Institute of Scientific and Technical Information of China (English)

    XU; Chi; XIE; Chun; WANG; Shu-xing; MI; Zheng-feng; YU; Tuan-jie; CUI; Chao; WANG; Ming-zheng

    2015-01-01

    In order to provide a high pure sodium environment for properties testing in the fuel research for fast reactor,it is essential to fill sodium into fuel testing capsules.By the method of vacuum,temperature-controlling and inert gas protection,quantificational sodium had been filled into the fuel testing capsules.Fig.1shows the schematic diagram of sodium filling device.Table 1shows

  5. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  6. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  7. A safety review for irradiation test of the creep capsule(02S-08K)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Seo, C. G.; Choi, M. H.; Choo, K. N.; Sohn, J. M.; Kang, Y. H.; Kim, B. G. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2004-07-01

    The creep capsule(02S-08K), which is aimed to confirm the design characteristics and the structural integrity, will be irradiated at the IR2 test hole in October, 2004. To review a safety in the irradiation test of the capsule, the reactivity effect in HANARO was analyzed and stress and temperatures on the capsule were estimated. In the abnormal operating condition during the test of the capsule, the effect exerted on the capsule outer body by leakage or breakage of the stress loading unit equipped in the capsule was analyzed.

  8. Halogen bonded supramolecular capsules: a challenging test case for quantum chemical methods.

    Science.gov (United States)

    Sure, Rebecca; Grimme, Stefan

    2016-08-02

    Recently, Diederich et al. synthesized the first supramolecular capsule with a well-defined four-point halogen bonding interaction [Angew. Chem., Int. Ed., 2015, 54, 12339]. This interesting system comprising about 400 atoms represents a challenging test case for accurate quantum chemical methods. We investigate it with our new density functional based composite method for structures and noncovalent interactions (PBEh-3c) as well as our standard protocol for supramolecular thermochemistry and give predictions for chemical modifications to improve the binding strength.

  9. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  10. Small sized slip-ring capsule endurance testing

    Science.gov (United States)

    Mondier, Jean-Bernard

    2005-07-01

    Slip-ring capsules are mechanical units used to carry electrical signals or power currents through a rotating joint. They are used either in solar array drive mechanisms (SADM) or in scientific instruments like radiometers. Analyses of the latest missions show that the slip-rings requirements are more and more demanding. For example, the number of in-orbit mechanical cycles keeps increasing. As a result, a signal slip-ring technology, which had been successfully tested for a given need, now has to improve its performances. It was therefore interesting to try to reach the slip-rings technical limits by testing them beyond the required performance of already known space missions. Slip-rings units are currently used in mechanisms such as SADM for the CNES Proteus and Myriade satellite family. They can be also found in the payload instruments of the Megha-Tropiques satellite project, namely Madras and Scarab. A selected hardware was tested at the mechanism endurance laboratory of the CNES, in Toulouse. The typical in-orbit rotation speed was increased in order to limit the test duration to 2 years. The main interest of this work was to provide a continuous slip-ring performance status and a large set of engineering data. The main test results are presented and discussed. The following lines also report a part of the hardware detailed inspection and the lessons learned.

  11. DETERMINATION OF THE AGR-1 CAPSULE TO FPMS SPECTROMETER TRANSPORT VOLUMES FROM LEADOUT FLOW TEST DATA

    Energy Technology Data Exchange (ETDEWEB)

    J. K. Hartwell; J. B. Walter; D. M. Scates; M. W. Drigert

    2007-05-01

    The AGR-1 experiment is a fueled multiple-capsule irradiation experiment being conducted in the Advanced Test Reactor (ATR) in support of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. A flow experiment conducted during the AGR-1 irradiation provided data that included the effect of flow rate changes on the decay of a short-lived radionuclide (23Ne). This data has been analyzed to determine the capsule-specific downstream transport volume through which the capsule effluents must pass before arrival at the fission product monitoring system spectrometers. These resultant transport volumes when coupled with capsule outlet flow rates determine the transport times from capsule-to-detector. In this work an analysis protocol is developed and applied in order to determine capsule-specific transport volumes to precisions of better than +/- 7%.

  12. Capsule 13C-urea breath test for the diagnosis of Helicobacter pylori infection

    Institute of Scientific and Technical Information of China (English)

    Nan-Jing Peng; Ping-I Hsu; Kwok-Hung Lai; Ren-Shyan Liu; Shui-Cheng Lee; Daw-Guey Tsay; Ching-Chu Lo; Huei-Hwa Tseng; Wen-Keui Huang; Gin-Ho Lo

    2005-01-01

    AIM: To compare the accuracy of capsule 13C-urea breath test (UBT) with conventional invasive methods for the diagnosis of Helicobacter pylori infection.METHODS: One hundred patients received CLO test,histological examination, culture and 100- or 50-mg capsule UBT for the diagnosis of Hpyloriinfection. Hpylori infection was defined as those with positive culture or positive results from both histology and CLO test.RESULTS: Both the sensitivity and specificity of the 100-mg capsule UBT (n = 50) were 100%. The sensitivity and specificity of the 50-mg capsule UBT (n = 50) were 96.4and 100%, respectively. Taken together, the accuracy of capsule UBT (n=100) was higher than that of CLO test,histology and culture (100% vs 92%, 91% and 89%,respectively; P= 0.035, 0.018 and 0.005, respectively). Our data showed that the optimal timing of sampling for 100-and 50-mg capsule UBT was 15-30 and 6-15 min, respectively.CONCLUSION: Capsule UBT has a higher accuracy compared with biopsy-based tests. It is an ideal method for the diagnosis of Hpyloriinfection.

  13. Long-duration life tests of slip ring capsule assemblies for inertial guidance platforms

    Science.gov (United States)

    Cole, S. R.; Glossbrenner, E. W.

    1974-01-01

    Eight slip ring capsules, each having 80 or 100 circuits, were operated for time periods ranging from 14,300 hours to 24,700 hours. The test mode simulated the motion of gimbal axes of the Saturn inertial guidance the platform in an organic free nitrogen environment. Computer-compiled noise data (approximately 45,000 recordings) were graphed as a function of test time and position within the capsules and as extreme probability distributions. Greater than ninety-nine percent of the noise measurements for the capsules with sufficient lubrication were less than 10 milliohms. Capsules with glass dielectrics did not perform significantly differently than those with filled epoxy dielectrics. The initial wear mode of prow formation was followed by rider wear. After 10 to the 8th power wipes, ring wear depth did not exceed the surface finish and the radial rider wear depth was less than 13 microns.

  14. Coracoid pain test: a new clinical sign of shoulder adhesive capsulitis

    OpenAIRE

    2009-01-01

    Patients with adhesive capsulitis were clinically evaluated to establish whether pain elicited by pressure on the coracoid area may be considered a pathognomonic sign of this condition. The study group included 85 patients with primary adhesive capsulitis, 465 with rotator cuff tear, 48 with calcifying tendonitis, 16 with glenohumeral arthritis, 66 with acromioclavicular arthropathy and 150 asymptomatic subjects. The test was considered positive when pain on the coracoid region was more sever...

  15. Drop Testing Representative Multi-Canister Overpacks

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Spencer D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Morton, Dana K. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    The objective of the work reported herein was to determine the ability of the Multi- Canister Overpack (MCO) canister design to maintain its containment boundary after an accidental drop event. Two test MCO canisters were assembled at Hanford, prepared for testing at the Idaho National Engineering and Environmental Laboratory (INEEL), drop tested at Sandia National Laboratories, and evaluated back at the INEEL. In addition to the actual testing efforts, finite element plastic analysis techniques were used to make both pre-test and post-test predictions of the test MCOs structural deformations. The completed effort has demonstrated that the canister design is capable of maintaining a 50 psig pressure boundary after drop testing. Based on helium leak testing methods, one test MCO was determined to have a leakage rate not greater than 1x10-5 std cc/sec (prior internal helium presence prevented a more rigorous test) and the remaining test MCO had a measured leakage rate less than 1x10-7 std cc/sec (i.e., a leaktight containment) after the drop test. The effort has also demonstrated the capability of finite element methods using plastic analysis techniques to accurately predict the structural deformations of canisters subjected to an accidental drop event.

  16. LOW DOSE CAPSULE BASED 13C-UREA BREATH TEST COMPARED WITH THE CONVENTIONAL 13C-UREA BREATH TEST AND INVASIVE TESTS

    Directory of Open Access Journals (Sweden)

    Rejane MATTAR

    2014-04-01

    Full Text Available Context One of the limitations of 13C-urea breath test for Helicobacter pylori infection diagnosis in Brazil is the substrate acquisition in capsule presentation. Objectives The purpose of this study was to evaluate a capsule-based 13C-urea, manipulated by the Pharmacy Division, for the clinical practice. Methods Fifty patients underwent the conventional and the capsule breath test. Samples were collected at the baseline and after 10, 20 and 30 minutes of 13C-urea ingestion. Urease and histology were used as gold standard in 83 patients. Results In a total of 50 patients, 17 were positive with the conventional 13C-urea (75 mg breath test at 10, 20 and 30 minutes. When these patients repeated breath test with capsule (50 mg, 17 were positive at 20 minutes and 15 at 10 and 30 minutes. The relative sensitivity of 13C-urea with capsule was 100% at 20 minutes and 88.24% at 10 and at 30 minutes. The relative specificity was 100% at all time intervals. Among 83 patients that underwent capsule breath test and endoscopy the capsule breath test presented 100% of sensitivity and specificity. Conclusions Capsule based breath test with 50 mg 13C-urea at twenty minutes was found highly sensitive and specific for the clinical setting. HEADINGS- Helicobacter pylori. Breath Test. Urea, analysis.

  17. Development and validation of a dissolution test for diltiazem hydrochloride in immediate release capsules

    Directory of Open Access Journals (Sweden)

    Taciane Ferreira Mendonça

    2011-01-01

    Full Text Available This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

  18. Out-pile test of the capsule with cone shape bottom structures

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M. H.; Kang, Y. H.; Cho, M. S.; Choo, K. N.; Kim, B. G.; Son, J. M.; Park, S. J.; Shin, Y. T.; Oh, J. M

    2004-01-01

    The design modification of bottom guide structures for the instrumented capsule which is used for the irradiation test in the research reactor, HANARO is done because of the cutting trouble of the bottom guide arm's pin. The previous structure of the 3-pin arm shape is changed into one body of the cone shape. The specimens of the bottom end cap ring with three different sizes ({phi}68mm, {phi}70mm, {phi}72mm) are designed and manufactured. The out-pile test for the capsule with previous 3-pin arm and new three bottom structures of the cone shape is performed using the one-channel flow test facilities. In order to estimate the compatibility with HANARO, the structural stability and integrity of the capsule, the out-pile test such as a loading/unloading test, a pressure drop test, a thermal performance test, a displacement measurement due to a vibration and an endurance test etc. is conducted, and the outer diameter of the bottom end cap ring to meet the HANARO requirements is selected. From out-pile test results the capsule with cone shape bottom structures is evaluated as to have the structural stability and the benefit from the fluid's flow respect. Also the size satisfied various requirements among three kinds of bottom end cap rings is 70mm in diameter. It is expected that the new bottom structures of the cone shape with 70mm in diameter will be applicable to all material and special capsules which will be designed and manufactured for the purpose of irradiation tests in the future.

  19. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  20. [Dissolution testing combined with computer simulation technology to evaluate the bioequivalence of domestic amoxicillin capsule].

    Science.gov (United States)

    Pan, Rui-Xue; Gao, Yuan; Chen, Wan-Li; Li, Yu-Lan; Hu, Chang-Qin

    2014-08-01

    Re-evaluation of bioequivalence of generic drugs is one of the key research focus currently. As a means to ensure consistency of the therapeutic effectiveness of drug products, clinical bioequivalence has been widely accepted as a gold standard test. In vitro dissolution testing based on the theory of the BCS is the best alternative to in vivo bioequivalence study. In this article, the conventional dissolution method and flow-through cell method were used to investigate the dissolution profiles of domestic amoxicillin capsules in different dissolution media, and the absorption behavior of the drugs with different release rates (t85% = 15-180 min) in the gastrointestinal tract was predicted by Gastro Plus. The flow-through cell method was thought better to reflect the release characteristics in vivo, and amoxicillin capsules with regard to the release rates up to 45 min (t85% = 45 min) were having a satisfied bioequivalence with the oral solution according to the C(max) and AUC. Although two different dissolution profiles of domestic amoxicillin capsules were found by flow-through cell methods, prediction results revealed that domestic capsules were probably bioequivalent to each other.

  1. Design and manufacturing of non-instrumented capsule for advanced PWR fuel pellet irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Song, K. W. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    This project is preparing to irradiation test of the developed large grain UO{sub 2} fuel pellet in HANARO for pursuit fuel safety and high burn-up in 'Advanced LWR Fuel Technology Development Project' as a part Nuclear Mid and Long-term R and D Program. On the basis test rod is performed the nuclei property and preliminary fuel performance analysis, test rod and non-instrumented capsule are designed and manufactured for irradiation test in HANARO. This non-instrumented irradiation capsule of Advanced PWR Fuel pellet was referred the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO(DUPIC Rig-001) and 18-element HANARO fuel, was designed to ensure the integrity and the endurance of non-instrumented capsule during the long term(2.5 years) irradiation. To irradiate the UO{sub 2} pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. This non-instrumented irradiation capsule will be based to develope the non-instrumented capsule for the more long term irradiation in HANARO. 22 refs., 13 figs., 5 tabs. (Author)

  2. 16 CFR 460.6 - “Representative thickness” testing.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false âRepresentative thicknessâ testing. 460.6 Section 460.6 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES LABELING AND ADVERTISING OF HOME INSULATION § 460.6 “Representative thickness” testing. All tests except aluminum...

  3. Coracoid pain test: a new clinical sign of shoulder adhesive capsulitis.

    Science.gov (United States)

    Carbone, S; Gumina, S; Vestri, A R; Postacchini, R

    2010-03-01

    Patients with adhesive capsulitis were clinically evaluated to establish whether pain elicited by pressure on the coracoid area may be considered a pathognomonic sign of this condition. The study group included 85 patients with primary adhesive capsulitis, 465 with rotator cuff tear, 48 with calcifying tendonitis, 16 with glenohumeral arthritis, 66 with acromioclavicular arthropathy and 150 asymptomatic subjects. The test was considered positive when pain on the coracoid region was more severe than 3 points (VAS scale) with respect to the acromioclavicular joint and the anterolateral subacromial area. The test was positive in 96.4% of patients with adhesive capsulitis and in 11.1%, 14.5%, 6.2% and 10.6% of patients with the other four conditions, respectively. A positive result was obtained in 3/150 normal subjects (2%). With respect to the other four diseases, the test had a sensitivity of 0.96 and a specificity ranging from 0.87 to 0.89. With respect to controls, the sensitivity and specificity were 0.99 and 0.98, respectively. The coracoid pain test could be considered as a pathognomonic sign in physical examination of patients with stiff and painful shoulder.

  4. Design, Fabrication and Test Report on a Verification Capsule (05M-06K) for the Control of a Neutron Irradiation Fluence of Specimens in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Choi, M. H.; Lee, D. S.

    2007-02-15

    As a part of a project for a capsule development and utilization for an irradiation test, a verification capsule (05M-06K) was designed, fabricated and tested for the development of new instrumented capsule technology for a more precise control of the irradiation fluence of a specimen, irrespective of the reactor operation condition. The basic structure of the 05M-06K capsule was based on the 04M-22K mock-up capsule which was successfully designed and out-pile tested to confirm the various key technologies necessary for the fluence control of a specimen. 21 square and round shaped specimens made of STS 304 were inserted into the capsule. The capsule was constructed in 5 stages with specimens and an independent electric heater at each stage. Each of the five specimens which were accommodated in the 1st stage (top) of the capsule can be taken out of the HANARO core during a normal reactor operation. The specimen is extracted by a specimen extraction mechanism using a steel wire. During the out-pile test, the temperatures of the specimens were measured by 12 thermocouples installed in the capsule. The capsule was successfully out-pile tested in a single channel test loop. The obtained results will be used for a safety evaluation of the new irradiation capsule for controlling the irradiation fluence of specimens in HANARO.

  5. Bio-relevant dissolution testing of hard capsules prepared from different shell materials using the dynamic open flow through test apparatus.

    Science.gov (United States)

    Garbacz, Grzegorz; Cadé, Dominique; Benameur, Hassan; Weitschies, Werner

    2014-06-16

    Current compendial dissolution and disintegrating testing is unable to mimic physiological conditions affecting gastric drug release from immediate release dosage forms. In order to obtain more realistic data, a novel test setup was developed that we term a 'dynamic open flow through test apparatus'. It is based on the previously described dissolution stress test device and attempts to simulate the intra-gastric dissolution conditions pertinent to immediate release dosage forms administered under fasting conditions with respect to flow rates, intra-gastric temperature profiles and gastric motility. The concept of the dynamic open flow through test apparatus has been tested using five different types of hard capsules: conventional hard gelatin capsules (HGC), three hypromellose based capsules (Vcaps, Vcaps Plus and DRcaps) and pullulan based capsules (Plantcaps). These were of different sizes but all contained 100mg caffeine in each formulation, adjusted to avoid buoyancy by addition of excipient. When the capsules were stressed in the apparatus under the dynamic flow conditions applying mild pressure simulating gastric motility, release from release from Vcaps Plus, Vcaps and Plantcaps capsules was very well comparable to HGC. Capsules are usually swallowed with cold water and the temperature dependency of release from gelatin was noted as a significant factor, since heat exchange in the stomach is slow. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Reference materials and representative test materials: the nanotechnology case

    Energy Technology Data Exchange (ETDEWEB)

    Roebben, G., E-mail: gert.roebben@ec.europa.eu [Joint Research Centre of the European Commission, Institute for Reference Materials and Measurements (Belgium); Rasmussen, K. [Joint Research Centre of the European Commission, Institute for Health and Consumer Protection (Italy); Kestens, V.; Linsinger, T. P. J. [Joint Research Centre of the European Commission, Institute for Reference Materials and Measurements (Belgium); Rauscher, H. [Joint Research Centre of the European Commission, Institute for Health and Consumer Protection (Italy); Emons, H. [Joint Research Centre of the European Commission, Institute for Reference Materials and Measurements (Belgium); Stamm, H. [Joint Research Centre of the European Commission, Institute for Health and Consumer Protection (Italy)

    2013-03-15

    An increasing number of chemical, physical and biological tests are performed on manufactured nanomaterials for scientific and regulatory purposes. Existing test guidelines and measurement methods are not always directly applicable to or relevant for nanomaterials. Therefore, it is necessary to verify the use of the existing methods with nanomaterials, thereby identifying where modifications are needed, and where new methods need to be developed and validated. Efforts for verification, development and validation of methods as well as quality assurance of (routine) test results significantly benefit from the availability of suitable test and reference materials. This paper provides an overview of the existing types of reference materials and introduces a new class of test materials for which the term 'representative test material' is proposed. The three generic concepts of certified reference material, reference material(non-certified) and representative test material constitute a comprehensive system of benchmarks that can be used by all measurement and testing communities, regardless of their specific discipline. This paper illustrates this system with examples from the field of nanomaterials, including reference materials and representative test materials developed at the European Commission's Joint Research Centre, in particular at the Institute for Reference Materials and Measurements (IRMM), and at the Institute for Health and Consumer Protection (IHCP).

  7. Turbulent mix or ion diffusion? Hypothesis testing in ICF capsule implosions

    Science.gov (United States)

    Hoffman, N. M.; Zimmerman, G. B.; Vander Wiel, S. A.; Herrmann, H. W.; Kim, Y. H.

    2016-10-01

    Turbulent mixing at a contact surface combines materials that are initially separated across the contact. While the mixing layer may contain the initially separate materials (each assumed to be composed of a number of distinct ion species) in a range of concentrations, from zero to 100%, the concentration of individual ion species within each material, relative to one another, is not altered by turbulent mixing alone. Ion diffusion likewise causes mixing at a contact, but does alter the relative concentration of ion species within each material, since the relative diffusivity of ions, in a fixed background plasma, varies as A 1 / 2/Z2. Recent hydrodynamically equivalent capsule implosions allow a test of the influence of these processes on observed capsule behavior. We use numerical simulations and hypothesis-testing methods to show quantitatively that turbulent mixing with ion diffusion is a better explanation of observed behavior than turbulent mixing alone (subject to the assumptions inherent in the computational models of these processes.) Research supported by US DOE under contract DE-AC52-06NA25396.

  8. Hypersonic Wind Tunnel Test of a Flare-type Membrane Aeroshell for Atmospheric Entry Capsules

    Science.gov (United States)

    Yamada, Kazuhiko; Koyama, Masashi; Kimura, Yusuke; Suzuki, Kojiro; Abe, Takashi; Koichi Hayashi, A.

    A flexible aeroshell for atmospheric entry vehicles has attracted attention as an innovative space transportation system. In this study, hypersonic wind tunnel tests were carried out to investigate the behavior, aerodynamic characteristics and aerodynamic heating environment in hypersonic flow for a previously developed capsule-type vehicle with a flare-type membrane aeroshell made of ZYLON textile sustained by a rigid torus frame. Two different models with different flare angles (45º and 60º) were tested to experimentally clarify the effect of flare angle. Results indicate that flare angle of aeroshell has significant and complicate effect on flow field and aerodynamic heating in hypersonic flow at Mach 9.45 and the flare angle is very important parameter for vehicle design with the flare-type membrane aeroshell.

  9. Studies on dissolution tests for soft gelatin capsules by the rotating dialysis cell (RDC) method. VI. Preparation and evaluation of ibuprofen soft gelatin capsule.

    Science.gov (United States)

    Takahashi, M; Yuasa, H; Kanaya, Y; Uchiyama, M

    1995-08-01

    We prepared soft gelatin capsules (SC) containing ibuprofen (IB), a widely used phenylpropionic acid-derived antiphlogistic-analgesic drug. To evaluate the SC, in vitro dissolution tests were performed both by the paddle (PD) method described in the Japanese Pharmacopoeia (JPXII) and by the rotating dialysis cell (RDC) method which we previously developed and evaluated for application. In vivo, the blood IB concentration was determined after administration to beagles. Higher bioavailability was observed after administration of the SC containing IB than after administration of the bulk IB powder. A higher correlation was observed between the in vitro dissolution behavior and in vivo results by the RDC method than by the PD method, suggesting the usefulness of the RDC method in the dissolution test of SC.

  10. Distension test in passive external rotation: Validation of a new clinical test for the early diagnosis of shoulder adhesive capsulitis.

    Science.gov (United States)

    Noboa, E; López-Graña, G; Barco, R; Antuña, S

    2015-01-01

    The aim of this study is to evaluate the internal validity of a clinical test for the early diagnosis of shoulder adhesive capsulitis, called the Distension Test in Passive External Rotation (DTPER). The DTPER is performed with the patient standing up, the arm adducted, and the elbow bent at 90°. From this position, a smooth passive external rotation is started, the affected arm being supporting at the wrist with one hand of the examiner and the other maintaining the adducted elbow until the maximum painless point of the rotation is reached. From this point of maximum external rotation with the arm in adduction and with no pain, an abrupt distension movement is made, increasing the external rotation, causing pain in the shoulder if the test is positive. This term was performed on a group of patients with shoulder pain of many origins, in order to analyse the predictive values, sensitivity, specificity, and the likelihood ratio. The DTPER showed a sensitivity of 100% (95% CI; 91.8 to 100%) and a specificity of 90% (95% CI; 82.4 to 94.8%). The positive predictive value was 0.62 and a likelihood ratio of 10.22 (95% CI; 5.5 to 19.01). False positives were only found in patients with subscapular tendinopathies or glenohumeral arthrosis. The DTPER has a high sensitivity for the diagnosis of adhesive capsulitis, and is excluded when it is practically negative. False positives can easily be identified if there is external rotation with no limits (subscapular tendinopathy) or with a simple shoulder X-ray (glenohumeral arthrosis). Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  11. The irradiation test plan and safety analysis of the creep capsule(03S-07K) equipped with double specimen

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Kim, B. G.; Choo, K. N.; Sohn, J. M.; Choi, M. H.; Kim, Y

    2005-04-15

    The irradiation test plan and safety analysis of the creep capsule(03S-07K) equipped with double specimen. In this report, the reactivity effect was reviewed and an analysis for the structural and thermal integrity was performed to review the safety of the creep capsule 03S-07K, which will be irradiated at a temperature higher than 550 .deg. C. The irradiation test will be performed at the in-core IR2 hole for 23 days at the 30 MWth power of HANARO. In the irradiation test, the temperature of the inside parts in the capsule will be measured and compared with the design value for reviewing the design data, and also the integrity of the bellows and LVDT etc. will be confirmed. The reactivity worth by the insertion of the creep capsule is no more than +9.2 mk, and this indicates that the reactivity effect does not exceed +12.5mk as specified in 'the HANARO operation technical specification'. The temperatures of the specimen, LVDT and the center rods of the bellows are less than the melting temperatures of the corresponding materials, therefore, the integrity of the materials are maintained. The center rod is made as a hollow tube shape of {phi}13mm x 2.5mmt of Ti material instead of the STS304 rod to lower the temperature. Thus, the temperature of the center rod of the bellows reaches 332{approx}1,095 .deg. C according to the vacuum condition of the capsules inside. By the structural analysis considering this temperature, the combined stress(the primary membrane and the secondary thermal) on the outer tube is 96.06 MPa for the HANARO 30 MWth power. The results of this stress analysis satisfiy the allowable stress limits.

  12. A study on the development of instrumented capsule for the material irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Park, J. M.; Choo, K. N.; Maeng, W. Y.; Park, D. K.; Oh, J. M.; Park, S. J.; Jung, S. H.; Park, J. S.; Kim, T. R.; Park, J. H.; Yang, S. Y.; Jun, Y. K.; Yang, S. H.

    1997-08-01

    Extensive efforts have been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO`s characteristics. (author). 86 refs., 45 tabs., 146 figs.

  13. Development and validation of dissolution testings in acidic media for rabeprazole sodium delayed-release capsules.

    Science.gov (United States)

    Tan, Yinhe; Si, Xiaoqing; Zhong, Lulu; Feng, Xin; Yang, Xinmin; Huang, Min; Wu, Chuanbin

    2016-10-01

    Rabeprazole sodium (RAB) dissolved in acidic media is accompanied by its degradation in the course of dissolution testing. To develop and establish the accumulative release profiles of ACIPHEX(®) Sprinkle (RAB) delayed-release capsules (ACIPHEX(®) Sprinkle) in acidic media using USP apparatus 2 (paddle apparatus) as a dissolution tester, the issues of determination of accumulative release amount of RAB in these acidic media and interference of hydroxypropylmethyl cellulose phthalate were solved by adding appropriate hydrochloric acid (HCl) into dissolution samples coupled with centrifugation so as to remove the interference and form a solution of degradation products of RAB, which is of a considerably stable ultraviolet (UV) absorbance at the wavelength of 298 nm within 2.0 h. Therefore, the accumulative release amount of RAB in dissolution samples at each sample time points could be determined by UV-spectrophotometry, and the accumulative release profiles of ACIPHEX(®) Sprinkle in the media of pH 1.0, pH 6.0, and pH 6.8 could be established. The method was validated per as the ICH Q2 (R1) guidelines and demonstrated to be adequate for quality control of ACIPHEX(®) Sprinkle and the accumulative release profiles can be used as a tool to guide the formulation development and quality control of a generic drug for ACIPHEX(®) Sprinkle.

  14. Dosimetry and reproducibility of a capsule-based C-14 urea breath test

    Energy Technology Data Exchange (ETDEWEB)

    Combs, M.J.; Stubbs, J.B.; Buck, D.A. [Univ. of Virginia, Charlottesville, VA (United States)]|[Oak Ridge Inst. for Science and Education, TN (United States)] [and others

    1995-05-01

    The aims of this study were (1) to determine the excretion of the C-14 and associated radiation dose and (2) to examine the reproducibility of a commercial C-14 urea breath test for H.pylori diagnosis. Tests were performed on twenty consenting volunteers (13M, 7F, 24-48 yr). Breath samples containing 1 mmol CO{sub 2} were obtained at 0,5,10,15,20,25,30 min. and 1,2,3,4,5,6,12, 24 hrs following administration of the 37kBq C-14 urea test capsule. A 24 hr urine collection was performed with each voiding collected separately. A repeat breath test was performed 24 hr after the first. H. pylori positive (HP+) was defined as a 15 minute breath sample >=50 dpm. Total urine excretion was obtained directly. Breath excretion was modeled by estimating the area under the excretion curve and using a constant factor of 884 mmol CO{sub 2}/ hr. Urine and breath excretion data in HP+ and H. pylori-negative (HP-) volunteers were pooled and fit to a monoexponential function thus estimating the cumulative urinary excretion of unmetabolized urea. Previously reported biokinetic models of C-14 urea and bicarbonate were used to estimate radiation doses form each compound. Weighted sums were calculated for each dose estimate using each group`s excretion fraction distribution. Both HP+ and HP- volunteers excreted an average of 73% of the C-14 over the first 24 hr. HP+ excretion was evenly divided between breath (34%) and urine (38%). HP-excretion is almost solely by the urinary pathway. The maximum dose for HP= was to the red marrow (0.0033 mGy) and a maximum of 0.0054 mGy to the urinary bladder wall for HP-. There was no difference between 15 inch breath samples on the two days (t-test, p>0.6). The minimum HP+ result at 15 inch was 270 dpm and the maximum HP- result at 15 inch was 18 dpm, indicating great separation between HP+ and HP- results. This study verifies previous dose estimates using C-14 excretion data. The test is sensitive and reproducible with a low radiation dose.

  15. Design, fabrication and irradiation test report on HANARO instrumented capsule (05M-07U) for the researches of universities in 2005

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Choi, M. H.; Cho, M. S.; Son, J. M.; Choi, M. H.; Shin, Y. T.; Park, S. J.

    2006-09-15

    As a part of the 2005 project for an active utilization of HANARO, an instrumented capsule (05M-07U) was designed, fabricated and irradiated for an irradiation test of various unclear materials under irradiation conditions which was requested by external researchers from universities. The basic structure of the 05M-07U capsule was based on the 00M-01U, 01M-05U, 02M-05U, 03M-06U and 04M-07U capsules which had been successfully irradiated in HANARO as part of the 2000, 2001, 2002, 2003 and 2004 projects. However, because of a limited number of specimens and the budget of one university, the remaining space in the capsule was filled with various KAERI specimens for researches on a nuclear core and SMART materials, and parts of a nuclear fuel assembly of KNFC. Various types of specimens such as tensile, Charpy, TEM, hardness, compression and growth specimens made of Zr 702, Ti and Ni alloys, Zirlo, Inconel, STS 316L and Cr-Mo alloys were placed in the capsule. Especially, this capsule was designed to evaluate the nuclear characteristics of the parts of a nuclear fuel assembly and the Ti tubes in HANARO. The capsule was composed of 5 stages having many kinds of specimens and an independent electric heater at each stage. During the irradiation test, the temperature of the specimens and the thermal/fast neutron fluences were measured by 14 thermocouples and 5 sets of Ni-Ti-Fe neutron fluence monitors installed in the capsule. The capsule was irradiated in the CT test hole of HANARO of a 30MW thermal output at 270 ∼ 400 .deg. C up to a fast neutron fluence of 5.7 x 10{sup 20} (n/cm{sup 2}) (E >1.0MeV). The obtained results will be very valuable for the related research of the users.

  16. Finite element modelling of the glenohumeral capsule can help assess the tested region during a clinical exam.

    Science.gov (United States)

    Ellis, Benjamin J; Drury, Nicholas J; Moore, Susan M; McMahon, Patrick J; Weiss, Jeffrey A; Debski, Richard E

    2010-06-01

    The objective of this research was to examine the efficacy of evaluating the region of the glenohumeral capsule being tested by clinical exams for shoulder instability using finite element (FE) models of the glenohumeral joint. Specifically, the regions of high capsule strain produced by glenohumeral joint positions commonly used during a clinical exam were identified. Kinematics that simulated a simple translation test with an anterior load at three external rotation angles were applied to a validated, subject-specific FE model of the glenohumeral joint at 60° of abduction. Maximum principal strains on the glenoid side of the inferior glenohumeral ligament (IGHL) were significantly higher than the maximum principal strains on the humeral side, for all three regions of the IGHL at 30° and 60° of external rotation. These regions of localised strain indicate that these joint positions might be used to test the glenoid side of the IGHL during this clinical exam, but are not useful for assessing the humeral side of the IGHL. The use of FE models will facilitate the search for additional joint positions that isolate high strains to other IGHL regions, including the humeral side of the IGHL.

  17. Capsule endoscopy

    Science.gov (United States)

    ... It is about the size of a large vitamin pill. The person swallows the capsule, and it takes pictures all the way through ... can be started in the doctor's office. The capsule is the size of a large vitamin pill, about an inch (2.5 centimeters) long ...

  18. Capsule endoscopy

    DEFF Research Database (Denmark)

    Skovsen, Anders Peter; Burcharth, Jakob; Burgdorf, Stefan Kobbelgaard

    2013-01-01

    with ultrasound, MRI, and subsequently a capsule endoscopy. Six months later, the patient presented, and an abdominal CT-scan showed mechanical small bowel obstruction with suspicion of metallic foreign body and perforation. Laparotomy showed perforation, stenosis, and foreign body, approximately 5 cm from...... the ileocecal valve. A right hemicolectomy and distal ileectomy (60 cm) with an ileostomy were performed. On further inspection of resection, a capsule endoscope was found impacted in a stenosis. The ileostomy was later reversed without complications. Conclusion. It is important to be aware of the possibility...... of capsule retention, especially in patients with known or suspected Crohn's disease, due to the propensity of Crohn's disease to form stenosis of the bowel. In cases where a stenosis is suspected, it is warranted to perform a patency capsule swallow before subjecting the patient to a capsule endoscopy....

  19. Development of neutron fluence measurement and evaluation technology for the test materials in the capsule

    Energy Technology Data Exchange (ETDEWEB)

    Hong, U.; Choi, S. H.; Kang, H. D. [Kyungsan University, Kyungsan (Korea)

    2000-03-01

    The four kinds of the fluence monitor considered by self-shielding are design and fabricated for evaluation of neutron irradiation fluence. They are equipped with dosimeters consisting of Ni, Fe and Ti wires and so forth. The nuclear reaction rate is obtained by measurement on dosimeter using the spectroscopic analysis of induced {gamma}-ray. We established the nuetron fluence evaluating technology that is based on the measurement of the reaction rate considering reactor's irradiation history, burn-out, self-shielding in fluence monitor, and the influence of impurity in dosimeter. The distribution of high energy neutron flux on the vertical axis of the capsule shows fifth order polynomial equation and is good agree with theoretical value in the error range of 30% by MCNP/4A code. 22 refs., 50 figs., 27 tabs. (Author)

  20. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  1. Influence of capsule shell composition on the performance indicators of hypromellose capsule in comparison to hard gelatin capsules.

    Science.gov (United States)

    Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani

    2015-01-01

    The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.

  2. 甜梦胶囊改善睡眠功能动物试验报告%Sweet dream capsule improving sleep function of animal test report

    Institute of Scientific and Technical Information of China (English)

    敬明武; 葛宇杰; 刘科亮

    2013-01-01

    目的探讨甜梦胶囊改善睡眠功能动物试验的效果。方法120只昆明种小鼠,分为三个剂量组进行试验。结果与结论甜梦胶囊连续31天经口灌胃给予动物后,动物生长良好,甜梦胶囊对动物具有改善睡眠的功能。%Objective To investigate the sweet dream capsule improving sleep function of animal test results. Methods 120 mice of Kunming species, divided into three groups for test. Results and Conclusion tianmeng capsule for 31 days after intragastric administration of animal, animal growth is good, sweet dream capsule can improve sleep function of animal.

  3. Antenna Measurements: Test & Analysis of the Radiated Emissions/Immunity of the NASA/Orion Spacecraft Dart Parachute Simulator & Prototype Capsule - The Crew Exploration Vehicle

    Science.gov (United States)

    Norgard, John D.

    2012-01-01

    For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary prototype parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of position, velocity, acceleration, attitude, temperature, pressure, humidity, and parachute loads. The primary and secondary (backup) avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. Intentional and unintentional radiation emitted from and received by antennas and electronic devices on/in the CEV capsule, the MDS sled, and the VCS system are being tested for radiated emissions/immunity (susceptibility) (RE/RS). To verify Electromagnetic Compatibility (EMC) of the Orion capsule, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC on the components of the CPAS system. Measurements are made at 1m from the components-under-test (CUT). In addition, EMI measurements of the integrated CEV system are being made inside a hanger at YPG. These measurements are made in a complete circle, at 30? angles or less, around the Orion Capsule, the spacecraft system under-test (SUT). Near-field B-Dot probe measurements on the surface of the Orion capsule are being extrapolated

  4. Continuous testing system for Baeyer-Villiger biooxidation using recombinant Escherichia coli expressing cyclohexanone monooxygenase encapsulated in polyelectrolyte complex capsules.

    Science.gov (United States)

    Bučko, Marek; Schenkmayerová, Andrea; Gemeiner, Peter; Vikartovská, Alica; Mihovilovič, Marko D; Lacík, Igor

    2011-08-10

    An original strategy for universal laboratory testing of Baeyer-Villiger monooxygenases based on continuous packed-bed minireactor connected with flow calorimeter and integrated with bubble-free oxygenation is reported. Model enantioselective Baeyer-Villiger biooxidations of rac-bicyclo[3.2.0]hept-2-en-6-one to corresponding lactones (1R,5S)-3-oxabicyclo-[3.3.0]oct-6-en-3-one and (1S,5R)-2-oxabicyclo-[3.3.0]oct-6-en-3-one as important chiral synthons for the synthesis of bioactive compounds were performed in the minireactor equipped with a column packed with encapsulated recombinant cells Escherichia coli overexpressing cyclohexanone monooxygenase. The cells were encapsulated in polyelectrolyte complex capsules formed by reaction of oppositely charged polymers utilizing highly reproducible and controlled encapsulation process. Encapsulated cells tested in minireactor exhibited high operational stability with 4 complete substrate conversions to products and 6 conversions above 80% within 14 repeated consecutive biooxidation tests. Moreover, encapsulated cells showed high enzyme stability during 91 days of storage with substrate conversions above 80% up to 60 days of storage. Furthermore, usable thermometric signal of Baeyer-Villiger biooxidation obtained by flow calorimetry using encapsulated cells was utilized for preparatory kinetic study in order to guarantee sub-inhibitory initial substrate concentration for biooxidation tests.

  5. Tests of shielding effectiveness of Kevlar and Nextel onboard the International Space Station and the Foton-M3 capsule.

    Science.gov (United States)

    Pugliese, M; Bengin, V; Casolino, M; Roca, V; Zanini, A; Durante, M

    2010-08-01

    Radiation assessment and protection in space is the first step in planning future missions to the Moon and Mars, where mission and number of space travelers will increase and the protection of the geomagnetic shielding against the cosmic radiation will be absent. In this framework, the shielding effectiveness of two flexible materials, Kevlar and Nextel, were tested, which are largely used in the construction of spacecrafts. Accelerator-based tests clearly demonstrated that Kevlar is an excellent shield for heavy ions, close to polyethylene, whereas Nextel shows poor shielding characteristics. Measurements on flight performed onboard of the International Space Station and of the Foton-M3 capsule have been carried out with special attention to the neutron component; shielded and unshielded detectors (thermoluminescence dosemeters, bubble detectors) were exposed to a real radiation environment to test the shielding properties of the materials under study. The results indicate no significant effects of shielding, suggesting that thin shields in low-Earth Orbit have little effect on absorbed dose.

  6. 76 FR 69585 - Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for...

    Science.gov (United States)

    2011-11-08

    ... the applicable periodic testing interval. The number of samples selected for the sampling procedure... requirement to test representative samples, by requiring each manufacturer of a children's product to select... the last periodic test occurred (or since certification for the first periodic tests). In order...

  7. Evaluation of Ciprofloxacin as a Representative of Veterinary Fluoroquinolones in Susceptibility Testing

    OpenAIRE

    Riddle, Christa; Lemons, Carol L.; Papich, Mark G.; Altier, Craig

    2000-01-01

    Currently in veterinary medicine, ciprofloxacin is often used in susceptibility testing to represent the entire class of fluoroquinolone antimicrobials. Using quality control organisms as well as clinical isolates, we compared the MIC of ciprofloxacin to those of three other fluoroquinolones used in animals and found that ciprofloxacin is not an adequate representative of other members of this class.

  8. Microcapsule-based self-healing anticorrosive coatings: Capsule size, coating formulation, and exposure testing

    DEFF Research Database (Denmark)

    Nesterova, Tatyana; Dam-Johansen, Kim; Pedersen, Lars Thorslund

    2012-01-01

    Self-healing coatings is a rapidly growing research area, where focus has mainly been on development of new approaches to the mechanism of self-healing. However, there is a growing need for investigation of practical issues related to formulation, application, and testing of true self-healing coa......Self-healing coatings is a rapidly growing research area, where focus has mainly been on development of new approaches to the mechanism of self-healing. However, there is a growing need for investigation of practical issues related to formulation, application, and testing of true self......-healing coatings. In this work, ways of reducing the size of poly(urea–formaldehyde) microcapsules, filled with linseed oil and intended for a microcapsule-based self-healing anticorrosive coating (above water exposure), are explored. The influence of microcapsules on epoxy coating performance is also studied...... a decrease in microcapsule size but were accompanied by excessive formation of nanoparticles. Thus, isolation of too large microcapsules has been performed by filtration utilizing a novel low-energy fluoropolymer-coated steel sieve. An estimation of the critical pigment (microcapsule) volume concentration...

  9. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (CAPSULE 2) of Ulchin Nuclear Power Plant Unit 3

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2006-12-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.674E 18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.920 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.913E 18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 9.249E 18 and 1.834E 19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  10. Final Report for the 1st Surveillance Test of the Reactor Pressure Vessel Material (Capsule 2) of Ulchin Nuclear Power Plant Unit 4

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai (and others)

    2007-04-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 1st surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejon after the capsule was transported from Ulchin site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Ulchin Unit 4 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsule 2 is 4.306E+18n/cm{sup 2}. The bias factor, the ratio of calculation/measurement, was 0.918 for the 1st testing and the calculational uncertainty,7.0% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 3.615E+18n/cm{sup 2} based on the end of 6th fuel cycle and it was predicted that the fluences of vessel inside surface at 16 and 32EFPY would reach 8.478E+18 and 1.673E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Ulchin Unit 4 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life.

  11. Collaborative testing for key-term definitions under representative conditions: Efficiency costs and no learning benefits.

    Science.gov (United States)

    Wissman, Kathryn T; Rawson, Katherine A

    2017-08-28

    Students are expected to learn key-term definitions across many different grade levels and academic disciplines. Thus, investigating ways to promote understanding of key-term definitions is of critical importance for applied purposes. A recent survey showed that learners report engaging in collaborative practice testing when learning key-term definitions, with outcomes also shedding light on the way in which learners report engaging in collaborative testing in real-world contexts (Wissman & Rawson, 2016, Memory, 24, 223-239). However, no research has directly explored the effectiveness of engaging in collaborative testing under representative conditions. Accordingly, the current research evaluates the costs (with respect to efficiency) and the benefits (with respect to learning) of collaborative testing for key-term definitions under representative conditions. In three experiments (ns = 94, 74, 95), learners individually studied key-term definitions and then completed retrieval practice, which occurred either individually or collaboratively (in dyads). Two days later, all learners completed a final individual test. Results from Experiments 1-2 showed a cost (with respect to efficiency) and no benefit (with respect to learning) of engaging in collaborative testing for key-term definitions. Experiment 3 evaluated a theoretical explanation for why collaborative benefits do not emerge under representative conditions. Collectively, outcomes indicate that collaborative testing versus individual testing is less effective and less efficient when learning key-term definitions under representative conditions.

  12. Capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Miguel Mu(n)oz-Navas

    2009-01-01

    Capsule endoscopy (CE) is a simple, safe, non-invasive, reliable technique, well accepted and tolerated by the patients, which allows complete exploration of the small intestine. The advent of CE in 2000 has dramatically changed the diagnosis and management of many diseases of the small intestine, such as obscure gastrointestinal bleeding, Crohn's disease, small bowel tumors, polyposis syndromes, etc. CE has become the gold standard for the diagnosis of most diseases of the small bowel. Lately this technique has also been used for esophageal and colonic diseases.

  13. Utility of the wireless motility capsule and lactulose breath testing in the evaluation of patients with Parkinson's disease who present with functional gastrointestinal symptoms

    Science.gov (United States)

    Su, Andrew; Gandhy, Rita; Barlow, Carrolee; Triadafilopoulos, George

    2017-01-01

    Background The aetiology and origin of gastrointestinal symptoms in Parkinson's disease (PD) remains poorly understood. Gastroparesis, small bowel transit delay and bacterial overgrowth may, individually or collectively, play a role. Aims In patients with PD and functional gastrointestinal symptoms, we aimed to determine the utility of the wireless motility capsule and lactulose breath tests in further defining their symptoms' aetiology. Methods In this retrospective cohort study, consecutive patients with PD and functional gastrointestinal symptoms underwent clinical assessment, as well as wireless motility capsule and lactulose breath testing using standard protocols. Results We studied 65 patients with PD and various gastrointestinal symptoms. 35% exhibited gastroparesis by the wireless motility capsule study, 20% small bowel transit delay, while 8% had combined transit abnormalities, suggestive of overlapping gastric and small bowel dysmotility. Small bowel bacterial overgrowth was seen in 34% of cases. Symptoms of abdominal pain, regurgitation, bloating, nausea, vomiting, belching and weight loss could not distinguish between patients with or without gastroparesis, although bloating was significantly more prominent (p<0.001) overall and specifically more so in patients with slow small bowel transit (p<0.01). There was no relationship between delayed small bowel transit time and bacterial overgrowth (p=0.5); PD scores and duration were not correlated with either the transit findings or small bowel bacterial overgrowth. Conclusions Functional gastrointestinal symptoms in patients with PD may reflect gastroparesis, small bowel transit delay or both, suggesting motor and/or autonomic dysfunction, and may be associated with small bowel bacterial overgrowth. The wireless motility capsule and lactulose breath testing are non-invasive and useful in the assessment of these patients.

  14. Required Be Capsule Strength For Room Temperature Transport

    Energy Technology Data Exchange (ETDEWEB)

    Cook, B

    2005-03-21

    The purpose of this memo is to lay out the criteria for the Be capsule strength necessary for room temperature transport. Ultimately we will test full thickness capsules by sealing high pressures inside, but currently we are limited to both thinner capsules and alternative measures of capsule material strength.

  15. Validation of Method for Microbial Limit Test of Feitai Capsules%肺泰胶囊微生物限度检查方法学验证

    Institute of Scientific and Technical Information of China (English)

    汤慧; 马杨红

    2015-01-01

    ABSTRACT:OBJECTIVE To establish microbial limit test method for Feitai capsules.METHODS The method for microbial limit examination in Chinese Pharmacopoeia was followed.RESULTS Feitai capsules showed inhibi-tion effect on Escherichia co1i,Bacillus subtilis,Staphylococcus aureus and Candida albicans.The effect could be e-liminated by culture medium dilution method.CONCLUSION Microbial limit test method was established for Feit-ai capsules and it is feasible and accurate.%目的:建立肺泰胶囊的微生物限度检查方法。方法按《中国药典》2010版一部方法进行试验。结果肺泰胶囊对大肠埃希菌、枯草芽孢杆菌、金黄色葡萄球菌、白色念珠菌有抑制作用,可以通过培养基稀释法予以消除。结论建立了肺泰胶囊的微生物限度检查方法,有效可靠。

  16. Generally representative is representative of none: commentary on the pitfalls of IQ test standardization in multicultural settings.

    Science.gov (United States)

    Shuttleworth-Edwards, A B

    2016-10-01

    The aim of this paper is to address the issue of IQ testing within the multicultural context, with a focus on the adequacy of nationwide population-based norms vs. demographically stratified within-group norms for valid assessment purposes. Burgeoning cultural diversity worldwide creates a pressing need to cultivate culturally fair psychological assessment practices. Commentary is provided to highlight sources of test-taking bias on tests of intellectual ability that may incur invalid placement and diagnostic decisions in multicultural settings. Methodological aspects of population vs. within-group norming solutions are delineated and the challenges of culturally relevant norm development are discussed. Illustrative South African within-group comparative data are supplied to support the review. A critical evaluation of the South African WAIS-III and the WAIS-IV standardizations further serves to exemplify the issues. A flaw in both South African standardizations is failure to differentiate between African first language individuals with a background of advantaged education vs. those from educationally disadvantaged settings. In addition, the standardizations merge the performance outcomes of distinct racial/ethnic groups that are characterized by differentially advantaged or disadvantaged backgrounds. Consequently, the conversion tables are without relevance for any one of the disparate South African cultural groups. It is proposed that the traditional notion of a countrywide unitary norming (also known as 'population-based norms') of an IQ test is an unsatisfactory model for valid assessment practices in diverse cultural contexts. The challenge is to develop new solutions incorporating data from finely stratified within-group norms that serve to reveal rather than obscure cross-cultural disparity in cognitive test performance.

  17. The association of matrix Gla protein isomers with calcification in capsules surrounding silicone breast implants.

    Science.gov (United States)

    Hunter, Larry W; Lieske, John C; Tran, Nho V; Miller, Virginia M

    2011-11-01

    Implanted silicone medical prostheses induce a dynamic sequence of histologic events in adjacent tissue resulting in the formation of a fibrotic peri-prosthetic capsule. In some cases, capsular calcification occurs, requiring surgical intervention. In this study we investigated capsules from silicone gel-filled breast prostheses to test the hypothesis that this calcification might be regulated by the small vitamin K-dependent protein, matrix Gla protein (MGP), a potent inhibitor of arterial calcification, or by Fetuin-A, a hepatocyte-derived glycoprotein also implicated as a regulator of pathologic calcification. Immunolocalization studies of explanted capsular tissue, using conformation-specific antibodies, identified the mineralization-protective γ-carboxylated MGP isomer (cMGP) within cells of uncalcified capsules, whereas the non-functional undercarboxylated isomer (uMGP) was typically absent. Both were upregulated in calcific capsules and co-localized with mineral plaque and adjacent fibers. Synovial-like metaplasia was present in one uncalcified capsule in which MGP species were differentially localized within the pseudosynovium. Fetuin-A was localized to cells within uncalcified capsules and to mineral deposits within calcific capsules. The osteoinductive cytokine bone morphogenic protein-2 localized to collagen fibers in uncalcified capsules. These findings demonstrate that MGP, in its vitamin K-activated conformer, may represent a pharmacological target to sustain the health of the peri-prosthetic tissue which encapsulates silicone breast implants as well as other implanted silicone medical devices.

  18. Unsedated peroral wireless pH capsule placement vs. standard pH testing: A randomized study and cost analysis

    Directory of Open Access Journals (Sweden)

    Andrews Christopher N

    2012-05-01

    Full Text Available Abstract Background Wireless capsule pH-metry (WC is better tolerated than standard nasal pH catheter (SC, but endoscopic placement is expensive. Aims: to confirm that non-endoscopic peroral manometric placement of WC is as effective and better tolerated than SC and to perform a cost analysis of the available esophageal pH-metry methods. Methods Randomized trial at 2 centers. Patients referred for esophageal pH testing were randomly assigned to WC with unsedated peroral placement or SC after esophageal manometry (ESM. Primary outcome was overall discomfort with pH-metry. Costs of 3 different pH-metry strategies were analyzed: 1 ESM + SC, 2 ESM + WC and 3 endoscopically placed WC (EGD + WC using publicly funded health care system perspective. Results 86 patients (mean age 51 ± 2 years, 71% female were enrolled. Overall discomfort score was less in WC than in SC patients (26 ± 4 mm vs 39 ± 4 mm VAS, respectively, p = 0.012 but there were no significant group differences in throat, chest, or overall discomfort during placement. Overall failure rate was 7% in the SC group vs 12% in the WC group (p = 0.71. Per patient costs ($Canadian were $1475 for EGD + WC, $1014 for ESM + WC, and $906 for ESM + SC. Decreasing the failure rate of ESM + WC from 12% to 5% decreased the cost of ESM + WC to $991. The ESM + SC and ESM + WC strategies became equivalent when the cost of the WC device was dropped from $292 to $193. Conclusions Unsedated peroral WC insertion is better tolerated than SC pH-metry both overall and during placement. Although WC is more costly, the extra expense is partially offset when the higher patient and caregiver time costs of SC are considered. Trial registration Clinicaltrials.gov Identifier NCT01364610

  19. Final Report on Design, Fabrication and Test of HANARO Instrumented Capsule (07M-13N) for the Researches of Irradiation Performance of Parts of X-Gen Nuclear Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H. (and others)

    2008-08-15

    An instrumented capsule of 07M-13N was designed, fabricated and irradiated for an evaluation of the neutron irradiation properties of the parts of a X-Gen nuclear fuel assembly for PWR requested by KNF. Some specimens of control rod materials of AP1000 reactor requested by Westinghouse Co. were inserted in this capsule as a preliminary irradiation test and Polyimide specimens requested by Hanyang university were also inserted. 463 specimens such as buckling and spring test specimens of cell spacer grid, tensile, microstructure and tensile of welded parts, irradiation growth, spring test specimens made of HANA tube, Zirlo, Zircaloy-4, Inconel-718, Polyimide, Ag and Ag-In-Cd alloys were placed in the capsule. During the irradiation test, the temperature of the specimens and the thermal/fast neutron fluences were measured by 14 thermocouples and 7 sets of neutron fluence monitors installed in the capsule. A new friction welded tube between STS304 and Al1050 alloys was introduced in the capsule to prevent a coolant leakage into a capsule during a capsule cutting process in HANARO. The capsule was irradiated for 95.19 days (4 cycles) in the CT test hole of HANARO of a 30MW thermal output at 230 {approx} 420 .deg. C. The specimens were irradiated up to a maximum fast neutron fluence of 1.27x10{sup 21}(n/cm{sup 2}) (E>1.0MeV) and the dpa of the irradiated specimens were evaluated as 1.21 {approx} 1.97. The irradiated specimens were tested to evaluate the irradiation performance of the parts of an X-Gen fuel assembly in the IMEF hot cell and the obtained results will be very valuable for the related researches of the users.

  20. Design and testing of a boron carbide capsule for spectral-tailoring in mixed-spectrum reactors

    Energy Technology Data Exchange (ETDEWEB)

    Greenwood, L.R.; Wittman, R. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Pierson, B.P. [Univ. of Michigan, Ann Arbor, MI 48109 (United States); Metz, L.A.; Payne, R.; Finn, E.C.; Friese, J.I. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States)

    2011-07-01

    A boron carbide capsule has been designed and used for spectral-tailoring experiments at the TRIGA reactor at Washington State Univ.. Irradiations were conducted in pulsed mode and in continuous operation for up to 4 h. A cadmium cover was used to reduce thermal heating. The neutron spectrum calculated with the Monte Carlo N-particle transport code was found to be in good agreement with reactor dosimetry measurements using the STAY'SL computer code. The neutron spectrum resembles that of a fast reactor. The design of a capsule using boron carbide fully enriched in {sup 10}B shows that it is possible to produce a neutron spectrum similar to that of {sup 235}U fission. (authors)

  1. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Younggwang nuclear power plant unit1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 1 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.555E+18, 1.662E+19, 3.358E+19, and 4.521E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.859 for the 1st through 4th testing and the calculational uncertainty, 11.80% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.551E+19 n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.929E+19, 4.880E+19, 5.831E+19 and 6.782E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 1 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 4 refs., 41 figs., 35 tabs. (Author)

  2. Final report for the 5th surveillance test of the reactor pressure vessel material (capsule Y) of Yonggwang Nuclear Power Plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sam Lai; Kim, ByoungChul; Chang, Kee Ok (and others)

    2006-02-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X, W and Y are 5.777E+18, 1.5371E+19, 3.7634E+19, 4.3045E+19, and 4.8662E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.953 for the 1st through 5th testing and the calculational uncertainty,7.2% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.659E+19n/cm{sup 2} based on the end of 13th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 48, 56 and 64EFPY would reach 3.625E+19, 5.293E+19, 6.127E+19 and 6.960E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the Pressurized Thermal Shock(PTS) during the operation until design life.

  3. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Yonggwang nuclear power plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-02-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.762E+18, 1.5391E+19, 3.5119E+19, and 4.2610E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.899 for the 1st through 4th testing and the calculational uncertainty, 12.3% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.357E+19 n/cm{sup 2} based on the end of 11th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.525E+19, 4.337E+19, 5.148E+19 and 5.960E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 42 tabs. (Author)

  4. BASICS OF COMPOUNDING: Capsules.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    Capsules have been used for administering medications to patients more than a century and have an important role in drug delivery. When a primary care provider prescribes a tablet, the choice is usually, but not always, limited to commercially available products. A capsule, however, can be prepared extemporaneously, which provides dosing flexibility for the primary care provider and the pharmacist. This article discusses the definitions/types of capsules, their applications, composition, preparation, capsule sizes, the encapsulation process, capsule cleaning, physiochemical considerations, quality control in the preparation of capsules, packaging/storage, stability, and patient counseling to determine the proper capsule size. Also, provided are sample formulations.

  5. Interim Report on Design, Fabrication and Test of HANARO Instrumented Capsule (07M-13N) for the Researches of Irradiation Performance of Parts of X-Gen Nuclear Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Choi, M. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Seo, C. G.; Kim, S. H.; Lee, J. H

    2008-02-15

    An instrumented capsule of 07M-13N was designed, fabricated and irradiated for and evaluation of the neutron irradiation properties of the parts of a a X-Gen nuclear fuel assembly for PWR requested by KNF (Korea Nuclear Fuel). The basic structure of the 07M-13N capsule was based on the 05M-07U capsule in which similar materials has been successfully irradiated in HANARO in 2006. Some specimens of control rod materials of AP1000 reactor requested by Westinghouse Co. were inserted in this capsule as a preliminary irradiation test and Polyimide specimens requested by Hanyang university were also inserted. 463 specimens such as bucking and spring test specimens of 1x1 cell spacer grid, tensile, microstructure and tensile of welded parts, irradiation growth, spring test specimens made of HANA tube, Zirlo, Zircaloy-4, Inconel-718, Polyimide, Ag and Ag-In-Cd alloys were placed in the capsule. The capsule was composed of 5 stages having many kinds of specimens and an independent electric heater at each stage. During the irradiation test, the temperature of the specimens and the thermal/fast neutron fluences were measured by 14 thermocouples and 7 sets of Ni-Ti-Fe neutron fluence monitors installed in the capsule. A new friction welded tube between STS304 and Al1050 alloys was introduced in the capsule to prevent a coolant leakage into a capsule during a capsule cutting process in HANARO. The capsule was irradiated for 49days (2 cycles) in the CT test hole of HANARO of a 30MW thermal output at 295 {approx} 460 .deg. C and maintained in the service pool because of reactor shut-down for the FTL construction. The specimen will be irradiated up to a maximum fast neutron fluence of 1.2x10{sup 21}(n/cm{sup 2}) (E>1.0MeV) after 4 cycle irradiation. The obtained results will be very valuable for the related researches of the users.

  6. 通心络胶囊微生物限度检查方法验证%Validation of microbial limit test for Tongxinluo capsule

    Institute of Scientific and Technical Information of China (English)

    戚继红; 蒋孜杰

    2015-01-01

    目的:对通心络胶囊的微生物限度检查方法进行方法学验证。方法按照《中国药典》2010版的规定,进行该品种微生物限度检查方法的验证。结果常规法试验显示通心络胶囊对金黄色葡萄球菌、枯草芽孢杆菌和黑曲霉菌有一定的抑制作用,回收率均﹤70%;培养基稀释法可消除上述3种菌的抑菌作用;控制菌测定中,各种阳性试验菌均能检出、阴性对照菌无菌生长。结论采用培养基稀释法对通心络胶囊进行细菌、霉菌和酵母菌测定;按常规法进行控制菌检查。%Objective To establish a method for the microbial limit test of Tongxinluo capsule. Methods According to the 2010 edition of the Chinese Pharmacopoeia,the microbiological test methods on tongxinluo capsule were validated. Re-sults By using the conventional test methods,the antibacterial actions of Tongxinluo capsule were showed for staphylococcus aureus,bacillus subtilis,aspergillus niger,the recovery rate was less than 70%. The culture medium dilution method could e-liminate the bacteriostasic activity for the above three strains. In the determination of control bacteria,all kinds of positive test bacteria can check out,the negative control bacteria was sterile growth. Conclusion The medium dilution method was used for the determination of bacteria,fungi and yeast for Tongxinluo capsule. Control bacteria was examined by conventional method.

  7. Positive attitudes to pediatric HIV testing: findings from a nationally representative survey from Zimbabwe.

    Directory of Open Access Journals (Sweden)

    Raluca Buzdugan

    Full Text Available OBJECTIVE: Early HIV testing and diagnosis are paramount for increasing treatment initiation among children, necessary for their survival and improved health. However, uptake of pediatric HIV testing is low in high-prevalence areas. We present data on attitudes towards pediatric testing from a nationally representative survey in Zimbabwe. METHODS: All 18-24 year olds and a proportion of 25-49 year olds living in randomly selected enumeration areas from all ten Zimbabwe provinces were invited to self-complete an anonymous questionnaire on a personal digital assistant, and 16,719 people agreed to participate (75% of eligibles. RESULTS: Most people think children can benefit from HIV testing (91%, 81% of people who looked after children know how to access testing for their children and 92% would feel happier if their children were tested. Notably, 42% fear that, if tested, children may be discriminated against by some community members and 28% fear their children are HIV positive. People who fear discrimination against children who have tested for HIV are more likely than their counterparts to perceive their community as stigmatizing against HIV positive people (43% vs. 29%. They are also less likely to report positive attitudes to HIV themselves (49% vs. 74%. Only 28% think it is possible for children HIV-infected at birth to live into adolescence without treatment. Approximately 70% of people (irrespective of whether they are themselves parents think HIV-infected children in their communities can access testing and treatment. CONCLUSIONS: Pediatric HIV testing is the essential gateway to prevention and care services. Our data indicate positive attitudes to testing children, suggesting a conducive environment for increasing uptake of pediatric testing in Zimbabwe. However, there is a need to better understand the barriers to pediatric testing, such as stigma and discrimination, and address the gaps in knowledge regarding HIV/AIDS in children.

  8. Reduction of the number of major representative allergens: from clinical testing to 3-dimensional structures.

    Science.gov (United States)

    He, Ying; Liu, Xueting; Huang, Yuyi; Zou, Zehong; Chen, Huifang; Lai, He; Zhang, Lida; Wu, Qiurong; Zhang, Junyan; Wang, Shan; Zhang, Jianguo; Tao, Ailin; Sun, Baoqing

    2014-01-01

    Vast amounts of allergen sequence data have been accumulated, thus complicating the identification of specific allergenic proteins when performing diagnostic allergy tests and immunotherapy. This study aims to rank the importance/potency of the allergens so as to logically reduce the number of allergens and/or allergenic sources. Meta-analysis of 62 allergenic sources used for intradermal testing on 3,335 allergic patients demonstrated that in southern China, mite, sesame, spiny amaranth, Pseudomonas aeruginosa, and house dust account for 88.0% to 100% of the observed positive reactions to the 62 types of allergenic sources tested. The Kolmogorov-Smironov Test results of the website-obtained allergen data and allergen family featured peptides suggested that allergen research in laboratories worldwide has been conducted in parallel on many of the same species. The major allergens were reduced to 21 representative allergens, which were further divided into seven structural classes, each of which contains similar structural components. This study therefore has condensed numerous allergenic sources and major allergens into fewer major representative ones, thus allowing for the use of a smaller number of allergens when conducting comprehensive allergen testing and immunotherapy treatments.

  9. Reduction of the Number of Major Representative Allergens: From Clinical Testing to 3-Dimensional Structures

    Directory of Open Access Journals (Sweden)

    Ying He

    2014-01-01

    Full Text Available Vast amounts of allergen sequence data have been accumulated, thus complicating the identification of specific allergenic proteins when performing diagnostic allergy tests and immunotherapy. This study aims to rank the importance/potency of the allergens so as to logically reduce the number of allergens and/or allergenic sources. Meta-analysis of 62 allergenic sources used for intradermal testing on 3,335 allergic patients demonstrated that in southern China, mite, sesame, spiny amaranth, Pseudomonas aeruginosa, and house dust account for 88.0% to 100% of the observed positive reactions to the 62 types of allergenic sources tested. The Kolmogorov-Smironov Test results of the website-obtained allergen data and allergen family featured peptides suggested that allergen research in laboratories worldwide has been conducted in parallel on many of the same species. The major allergens were reduced to 21 representative allergens, which were further divided into seven structural classes, each of which contains similar structural components. This study therefore has condensed numerous allergenic sources and major allergens into fewer major representative ones, thus allowing for the use of a smaller number of allergens when conducting comprehensive allergen testing and immunotherapy treatments.

  10. Research on the microbial limit verification test of tacrolimus capsules%他克莫司胶囊微生物限度检查法验证的探讨

    Institute of Scientific and Technical Information of China (English)

    占景华; 石鹤坤; 钟渊福; 董智聪; 胡永狮

    2014-01-01

    目的:按2010版《中国药典》的要求探讨他克莫司胶囊微生物限度检测方法。方法选取5种具有代表性的微生物菌悬液,用常规法、稀释法、膜过滤法或其相结合的方法分别对他克莫司胶囊进行微生物验证试验。结果细菌总数用膜过滤法稀释1∶10,霉菌和酵母菌用膜过滤法稀释1∶1000,检测后回收率均能达到70%以上。结论避免采用单一常规法或膜过滤法进行微生物限度检测,使实验科学合理,提高工作效率,更加规范性。%Objective To research the microbial limit verification test of tacrolimus capsules according to the requirements of the 2010-edition Chinese Pharmacopoeia. Methods Five types of representative microbial bacterial suspension were selected and then microbial verification tests on tacrolimus capsules through the conventional method, the dilution method,the membrane filtration method or a combination of the above methods respectively were carried out. Results Both of the recovery rates were more than 70%when the total number of bacterial was detected by the membrane filtration method as per 1∶10 and when mould and yeast were detected by the membrane filtration method as per 1∶1 000. Conclusion Microbial limit test through the single conventional method or membrane filtration method is avoided so as to ensure scientific and reasonable experiment,improve work efficiency and achieve normalization.

  11. Comprehensive In Vitro Toxicity Testing of a Panel of Representative Oxide Nanomaterials: First Steps towards an Intelligent Testing Strategy.

    Directory of Open Access Journals (Sweden)

    Lucian Farcal

    Full Text Available Nanomaterials (NMs display many unique and useful physico-chemical properties. However, reliable approaches are needed for risk assessment of NMs. The present study was performed in the FP7-MARINA project, with the objective to identify and evaluate in vitro test methods for toxicity assessment in order to facilitate the development of an intelligent testing strategy (ITS. Six representative oxide NMs provided by the EC-JRC Nanomaterials Repository were tested in nine laboratories. The in vitro toxicity of NMs was evaluated in 12 cellular models representing 6 different target organs/systems (immune system, respiratory system, gastrointestinal system, reproductive organs, kidney and embryonic tissues. The toxicity assessment was conducted using 10 different assays for cytotoxicity, embryotoxicity, epithelial integrity, cytokine secretion and oxidative stress. Thorough physico-chemical characterization was performed for all tested NMs. Commercially relevant NMs with different physico-chemical properties were selected: two TiO2 NMs with different surface chemistry - hydrophilic (NM-103 and hydrophobic (NM-104, two forms of ZnO - uncoated (NM-110 and coated with triethoxycapryl silane (NM-111 and two SiO2 NMs produced by two different manufacturing techniques - precipitated (NM-200 and pyrogenic (NM-203. Cell specific toxicity effects of all NMs were observed; macrophages were the most sensitive cell type after short-term exposures (24-72h (ZnO>SiO2>TiO2. Longer term exposure (7 to 21 days significantly affected the cell barrier integrity in the presence of ZnO, but not TiO2 and SiO2, while the embryonic stem cell test (EST classified the TiO2 NMs as potentially 'weak-embryotoxic' and ZnO and SiO2 NMs as 'non-embryotoxic'. A hazard ranking could be established for the representative NMs tested (ZnO NM-110 > ZnO NM-111 > SiO2 NM-203 > SiO2 NM-200 > TiO2 NM-104 > TiO2 NM-103. This ranking was different in the case of embryonic tissues, for which TiO2

  12. New respirator fit test panels representing the current Chinese civilian workers.

    Science.gov (United States)

    Chen, Weihong; Zhuang, Ziqing; Benson, Stacey; Du, Lili; Yu, Dan; Landsittel, Douglas; Wang, Limin; Viscusi, Dennis; Shaffer, Ronald E

    2009-04-01

    Respirator fit test panels provide an objective tool for selecting representative human test subjects based upon their facial characteristics for use in research, product development, testing and certification. Fit test panels were typically based upon anthropometric data such as the 1967-1968 survey of American military personnel. In this study, the objectives were to: (i) evaluate the applicability of the recently developed National Institute for Occupational Safety and Health (NIOSH) respirator fit test panels for Chinese workers and (ii) develop new respirator fit test panels using the Chinese survey data. Overall, 95% of the workers in the Chinese survey fall within the NIOSH bivariate and principal component analysis (PCA) panels, suggesting that these panels would also be appropriate for the Chinese population. However, distribution of the subject across the panels was not uniform; only 6.3% of survey participants fell into five cells of the bivariate panel and only 7.2% were found within three cells of the PCA panel. Therefore, new respirator fit test panels with subject dimensions and distributions specific to Chinese workers may be beneficial for certain applications. Two new respirator fit test panels were developed with the same techniques used to create the NIOSH panels. All measurements were weighted to match age and gender distributions of the Chinese population from the 2005 census. The bivariate approach used face length and face width measurements, and the PCA panel was developed using the first two principal components obtained from a set of 10 facial dimensions. Respirators designed to fit these Chinese worker-specific panels are also likely to accommodate >95% of Chinese workers.

  13. Reprocessing of dental instruments in washer-disinfectors: does a representative test soil exist in dentistry?

    Science.gov (United States)

    Franz, Alexander; Bristela, Margit; Stauffer, Fritz

    2012-01-01

    Reprocessing of medical devices, being classified as semi-critical B is recommended to be performed in a washer-disinfector. In order to estimate, whether the expected contaminants of the various medical disciplines can be effectively removed by this washer-disinfector, different so called "test soils" have been proposed to be tested as a marker of cleaning efficacy of the disinfector. Todays described test soils are optimised for the testing of contaminations occurring in surgical procedures, but not for dental procedures. In this study the test soils being proposed in the EN 15883-5 (e.g. KMNE soil, recipe by Koller and coagulated sheep's blood) were compared with 8 reference substances used in the conservative-prosthetic dental practice. The success of the cleaning efficacy in the washer-disinfector was checked visually and by determining the residual protein concentration on the contaminated instruments after the cleaning procedure. It could be shown that in contrast to the proposed test soils of the EN 15883-5, the used reference substances of the dental practice could not be removed by the washer-disinfector. Removal of these reference substances was only possible after manual or ultrasonic cleaning. Since blood plays a subordinate role as a contaminant of instruments during conservative-prosthetic dental treatments, testing of the cleaning efficacy of the washer-disinfector with test soils according to the proposals of the EN 15883-5 is not representative in this discipline of dentistry. Most of the materials used in dental practice can only be removed manually or with the help of the ultrasound bath.

  14. New respirator fit test panels representing the current U.S. civilian work force.

    Science.gov (United States)

    Zhuang, Ziqing; Bradtmiller, Bruce; Shaffer, Ronald E

    2007-09-01

    The fit test panels currently used for respirator research, design, and certification are 25-subject panels developed by Los Alamos National Laboratory (LANL) and are based on data from the 1967 and 1968 anthropometric surveys of U.S. Air Force personnel. Military data do not represent the great diversity in face size and shape seen in civilian populations. In addition, the demographics of the U.S. population have changed over the last 30 years. Thus, it is necessary to assess and refine the LANL fit test panels. This paper presents the development of new respirator fit test panels representative of current U.S. civilian workers based on an anthropometric survey of 3,997 respirator users conducted in 2003. One panel was developed using face length and face width (bivariate approach) and weighting subjects to match the age and race distribution of the U.S. population as determined from the 2000 census. Another panel was developed using the first two principal components obtained from a set of 10 facial dimensions (age and race adjusted). These 10 dimensions are associated with respirator fit and leakage and can predict the remaining face dimensions well. Respirators designed to fit these panels are expected to accommodate more than 95% of the current U.S. civilian workers. Both panels are more representative of the U.S. population than the existing LANL panel and may be appropriate for testing both half-masks and full-face piece respirators. Respirator manufacturers, standards development organizations, and government respirator certification bodies need to select the appropriate fit test panel for their particular needs. The bivariate panel is simpler to use than the principal component analysis (PCA) panel and is most similar to the LANL panel currently used. The inclusion of the eight additional facial measurements allows the PCA panel to provide better criteria for excluding extreme face sizes from being used. Because the boundaries of the two new panels are

  15. [Trait stability and test site representativeness of sugarcane varieties based on GGE-biplot analysis].

    Science.gov (United States)

    Luo, Jun; Zhang, Hua; Deng, Zu-Hu; Que, You-Xiong

    2012-05-01

    Arithmetic mean method is commonly used to evaluate the yield stability and adaptability of sugarcane varieties, and variance analysis is applied to estimate the errors in regional trials. However, it is difficult to accurately evaluate the differences of the varieties due to the discrepancies across test sites and years. In this paper, GGE-biplot method was adopted to analyze the data from the regional trials with seven sugarcane varieties at five sites from 2008 to 2009, aimed to objectively evaluate the yield stability and adaptability of sugarcane varieties in China. Among the test sugarcane varieties, Funong No. 30 had higher cane yield and better yield stability, Yuegan No. 18 had higher sugar content and better trait stability, Funong No. 28 and Yunzhe 99-91 had high sucrose content and trait stability, while Yuegan No. 16 had the highest cane yield and sugar content but ordinary stability. In the test sites, Zhangzhou City in Fujian Province and Suixi City in Guangdong Province had the best representativeness and discrimination. This study showed that GGE-biplot analysis provided a simple and effective method to analyze the high yield and stability of sugarcane varieties in regional trials, and supplied the basis for the approval and extension of new sugarcane varieties.

  16. Intuitive intellectual property law: A nationally-representative test of the plagiarism fallacy.

    Science.gov (United States)

    Fast, Anne A; Olson, Kristina R; Mandel, Gregory N

    2017-01-01

    Studies with convenience samples have suggested that the lay public's conception of intellectual property laws, including how the laws should regulate and why they should exist, are largely incommensurate with the actual intended purpose of intellectual property laws and their history in the United States. In this paper, we test whether these findings generalize to a more diverse and representative sample. The major findings from past work were replicated in the current study. When presented with several potential reasons for IP protection, the lay public endorsed plagiarism and felt that acknowledging the original source of a creative work should make copying that work permissible-viewpoints strongly divergent from lawmakers' intent and the law itself. In addition, we replicate the finding that lay people know remarkably little about intellectual property laws more generally and report little experience as users or creators of creative works.

  17. Comprehensive In Vitro Toxicity Testing of a Panel of Representative Oxide Nanomaterials: First Steps towards an Intelligent Testing Strategy

    Science.gov (United States)

    Farcal, Lucian; Torres Andón, Fernando; Di Cristo, Luisana; Rotoli, Bianca Maria; Bussolati, Ovidio; Bergamaschi, Enrico; Mech, Agnieszka; Hartmann, Nanna B.; Rasmussen, Kirsten; Riego-Sintes, Juan; Ponti, Jessica; Kinsner-Ovaskainen, Agnieszka; Rossi, François; Oomen, Agnes; Bos, Peter; Chen, Rui; Bai, Ru; Chen, Chunying; Rocks, Louise; Fulton, Norma; Ross, Bryony; Hutchison, Gary; Tran, Lang; Mues, Sarah; Ossig, Rainer; Schnekenburger, Jürgen; Campagnolo, Luisa; Vecchione, Lucia; Pietroiusti, Antonio; Fadeel, Bengt

    2015-01-01

    Nanomaterials (NMs) display many unique and useful physico-chemical properties. However, reliable approaches are needed for risk assessment of NMs. The present study was performed in the FP7-MARINA project, with the objective to identify and evaluate in vitro test methods for toxicity assessment in order to facilitate the development of an intelligent testing strategy (ITS). Six representative oxide NMs provided by the EC-JRC Nanomaterials Repository were tested in nine laboratories. The in vitro toxicity of NMs was evaluated in 12 cellular models representing 6 different target organs/systems (immune system, respiratory system, gastrointestinal system, reproductive organs, kidney and embryonic tissues). The toxicity assessment was conducted using 10 different assays for cytotoxicity, embryotoxicity, epithelial integrity, cytokine secretion and oxidative stress. Thorough physico-chemical characterization was performed for all tested NMs. Commercially relevant NMs with different physico-chemical properties were selected: two TiO2 NMs with different surface chemistry – hydrophilic (NM-103) and hydrophobic (NM-104), two forms of ZnO – uncoated (NM-110) and coated with triethoxycapryl silane (NM-111) and two SiO2 NMs produced by two different manufacturing techniques – precipitated (NM-200) and pyrogenic (NM-203). Cell specific toxicity effects of all NMs were observed; macrophages were the most sensitive cell type after short-term exposures (24-72h) (ZnO>SiO2>TiO2). Longer term exposure (7 to 21 days) significantly affected the cell barrier integrity in the presence of ZnO, but not TiO2 and SiO2, while the embryonic stem cell test (EST) classified the TiO2 NMs as potentially ‘weak-embryotoxic’ and ZnO and SiO2 NMs as ‘non-embryotoxic’. A hazard ranking could be established for the representative NMs tested (ZnO NM-110 > ZnO NM-111 > SiO2 NM-203 > SiO2 NM-200 > TiO2 NM-104 > TiO2 NM-103). This ranking was different in the case of embryonic tissues, for

  18. Esophageal capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Raul Armendariz; Miguel Mu(n)oz-Navas

    2008-01-01

    Capsule endoscopy is now considered as the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Esophageal capsule endoscopy in patients with suspected esophageal disorders is feasible and safe,and could be also an alternative procedure in those patients refusing upper endoscopy.Although large-scale studies are needed to confirm its utility in GERD and cirrhotic patients,current results are encouraging and open a new era in esophageal examination.

  19. Colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Ana Borda; Miguel Mu(n)oz-Navas

    2008-01-01

    Wireless capsule endoscopy has become the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Clinical trials results have shown that colon capsule endoscopy is feasible,accurate and safe in patients suffering from colonic diseases.It could be a good alternative in patients refusing conventional colonoscopy or when it is contraindicated.Upcoming studies are needed to demonstrate its utilty for colon cancer screening and other indications such us ulcerative colitis.Comparative studies including both conventional and virtual colonoscopy are also required.

  20. Clinical Efficacy of Various Diagnostic Tests for Small Bowel Tumors and Clinical Features of Tumors Missed by Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Jung Wan Han

    2015-01-01

    Full Text Available Background. We aimed to evaluate the efficacy of various diagnostic tools such as computerized tomography (CT, small bowel follow-through (SBFT, and capsule endoscopy (CE in diagnosing small bowel tumors (SBTs. Additionally, we aimed to evaluate the clinical features of SBTs missed by CE. Methods. We retrospectively studied 79 patients with histologically proven SBT. Clinical data were analyzed with particular attention to the efficacy of CT, SBFT, and CE in detecting SBT preoperatively. We also analyzed the clinical features of SBTs missed by CE. Results. The most common symptoms of SBT were bleeding (43% and abdominal pain (13.9%. Diagnostic yields were as follows: CT detected 55.8% of proven SBTs; SBFT, 46.1%; and CE, 83.3%. The sensitivity for detecting SBTs was 40.4% for CT, 43.9% for SBFT, and 79.6% for CE. Two patients with nondiagnostic but suspicious findings on CE and seven patients with negative findings on CE were eventually found to have SBT. These nine patients were eventually diagnosed with gastrointestinal stromal tumor (4, small polyps (3, inflammatory fibroid polyp (1, and adenocarcinoma (1. These tumors were located in the proximal jejunum (5, middle jejunum (1, distal jejunum (1, and proximal ileum (1. Conclusion. CE is more efficacious than CT or SBFT for detecting SBTs. However, significant tumors may go undetected with CE, particularly when located in the proximal jejunum.

  1. The Symbol Digit Modalities Test: Normative data from a large nationally representative sample of Australians.

    Science.gov (United States)

    Kiely, Kim M; Butterworth, Peter; Watson, Nicole; Wooden, Mark

    2014-12-01

    Data from the Household, Income and Labour Dynamics in Australia (HILDA) Survey were used to calculate weighted norms for the written version of the Symbol Digits Modalities Test (SDMT) by gender, 5-year age groups and four levels of educational attainment. The sample comprised 14,456 Australians (47% male; age range 15-100), of whom 25% reported a tertiary qualification, 30% reported a technical qualification (diploma or trade certificate), 16% reported completing Year 12 (final year of high school), and 29% reported their highest level of educational attainment to be Year 11 or below. Participants were excluded if they reported physical or neurological conditions that limited performance. Age, gender, and education were all significantly associated with SDMT performance, as was poor health, and cultural background. The reported norms are of greater scope and precision than previously available and have utility in a range of clinical and research settings. Indeed, normative data for the SDMT that are representative of a national population have not previously been published. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. NIF capsule performance modeling

    OpenAIRE

    Weber S.; Callahan D.; Cerjan C.; Edwards M.; Haan S.; Hicks D.; Jones O.; Kyrala G.; Meezan N.; Olson R; Robey H.; Spears B.; Springer P.; Town R.

    2013-01-01

    Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting th...

  3. [Karyosphere capsule in Tribolium castaneum oocytes].

    Science.gov (United States)

    Batalova, F M; Bogoliubov, D S

    2013-01-01

    Structure and composition of the karyosphere (karyosome) capsule were studied in the oocytes of a laboratory insect, Tribolium castaneum, with the use of electron microscopy and immunoelectron cytochemistry. Basing on the study of nuclear structure dynamics, we distinguished 8 stages that characterize the period of oocyte growth. At the diplotene stage, T. castaneum oocyte chromosomes conjoin early into a compact karyosphere, but a significant chromatin condensation does not occur. The process of karyosphere formation is accompanied by the development of an extensive extrachromosome capsule surrounding chromatin. The capsule consists of a material of different morphological types. Significant molecular components of the T. castaneum karyosphere capsule are represented by the proteins of nuclear matrix including F-actin and lamin B. Besides the structural proteins, the Sm proteins of small nuclear (sn) RNPs and mature 2,2,7-trimethyl guanosine (TMG) 5'-capped snRNAs are revealed immunocytochemically in the karyosphere capsule. The obtained data can form a basis for further expansion of ideas on the functions of the karyosphere capsule as a specialized extrachromosomal nuclear domain of the oocytes. We believe that the T. castaneum karyosphere capsule plays not only a structural role, but may be involved directly in the processes related to gene expression.

  4. Fecal occult blood testing for the prediction of small-bowel pathology detected by capsule endoscopy: a systematic review and meta-analysis

    Science.gov (United States)

    Yung, Diana E.; Vijayan, Sanju; Avni, Tomer; Douglas, Sarah; Kopylov, Uri; Koulaouzidis, Anastasios

    2017-01-01

    Background Fecal occult blood testing (FOBT) has been suggested as a potential screening tool for small-bowel capsule endoscopy (CE). We conducted a meta-analysis of studies correlating FOBT and CE findings to examine the predictive value of positive FOBT for CE findings. Methods PubMed and Embase search. Sensitivity, specificity and diagnostic odds ratios (DORs) were calculated. Results Six studies were identified. Four used fecal immunochemical testing (FIT), one used FIT and guaiac FOBT, one used hemoglobin/haptoglobin complex testing (Hb/Hpt). Five of the 6 studies were suitable for statistical analysis. For all positive FOBT, sensitivity for small-bowel findings was 0.60 (95%CI 0.50-0.69), specificity was 0.72 (95%CI 0.52-0.86), and DOR was 3.96 (95%CI 1.50-10.4). For the 4 studies using only FIT, sensitivity was 0.48 (95%CI 0.36-0.61), specificity was 0.60 (95%CI 0.42-0.76), and DOR was 1.41 (95%CI 0.72-2.75). Conclusions Although a number of modalities have been suggested for screening small-bowel CE referrals, none of them, including FOBT, offer a comprehensive solution. Further work is required to refine screening methods for small-bowel CE referrals.

  5. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  6. Reprocessing of dental instruments in washer-disinfectors: does a representative test soil exist in dentistry?

    OpenAIRE

    Franz, A.; Bristela, M.; Stauffer, F

    2012-01-01

    Background: Reprocessing of medical devices, being classified as semi-critical B is recommended to be performed in a washer-disinfector. In order to estimate, whether the expected contaminants of the various medical disciplines can be effectively removed by this washer-disinfector, different so called "test soils" have been proposed to be tested as a marker of cleaning efficacy of the disinfector. Todays described test soils are optimised for the testing of contaminations occurring in surgic...

  7. Lightweight, highly compressible, noncrystalline cellulose capsules.

    Science.gov (United States)

    Carrick, Christopher; Lindström, Stefan B; Larsson, Per Tomas; Wågberg, Lars

    2014-07-08

    We demonstrate how to prepare extraordinarily deformable, gas-filled, spherical capsules from nonmodified cellulose. These capsules have a low nominal density, ranging from 7.6 to 14.2 kg/m(3), and can be deformed elastically to 70% deformation at 50% relative humidity. No compressive strain-at-break could be detected for these dry cellulose capsules, since they did not rupture even when compressed into a disk with pockets of highly compressed air. A quantitative constitutive model for the large deformation compression of these capsules is derived, including their high-frequency mechanical response and their low-frequency force relaxation, where the latter is governed by the gas barrier properties of the dry capsule. Mechanical testing corroborated these models with good accuracy. Force relaxation measurements at a constant compression rendered an estimate for the gas permeability of air through the capsule wall, calculated to 0.4 mL μm/m(2) days kPa at 50% relative humidity. These properties taken together open up a large application area for the capsules, and they could most likely be used for applications in compressible, lightweight materials and also constitute excellent model materials for adsorption and adhesion studies.

  8. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  9. Long Term Out-of-pile Thermocouple Tests in Conditions Representative for Nuclear Gas-cooled High Temperature Reactors

    OpenAIRE

    LAURIE Mathias; FOURREZ Stephane; FUETTERER Michael; LAPETITE Jean-Marc

    2011-01-01

    During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remediate this problem, out-ofpile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of...

  10. Validation of Methods for Microbial Limit Test of Ganyu Capsules%感愈胶囊微生物限度检查方法验证

    Institute of Scientific and Technical Information of China (English)

    王荭晖; 徐庆辉

    2009-01-01

    Objective To establish a method for microbial limit test of Ganyu capsules. Methods The method for microbial limit examination in Chinese Pharmacopoeia was followed. The validation had been tested by recovery. Results With direct inoculation method and medium diluted method(0.5 mL/dish),the rations of all test microbial group were lower than 70%.With medium diluted method(0.1 mL/dish),the rations of Aspergillus nigers and Candida albicans were higher than 70%.With filtration membrane ,all the ratios were higher than 70%. Conclusion In this validation of method for microbial limit should use filtration membrane method, the mould (yeast) and the controls bacterium should use direct inoculation method.%目的 建立感愈胶囊微生物限度检查法.方法 按现行版规定的方法试验,以回收率对方法的有效性进行评价.结果 采用直接接种法和培养基稀释法(0.5mL/皿),5种阳性菌回收率均<70%;采用培养基稀释法(0.1 mL/皿),黑曲霉菌和白色念珠菌回收率70%;采用薄膜过滤法,3种阳性菌回收率均70%.结论 本品微生物限度检查法中细菌检查应采用薄膜过滤法,霉菌(酵母菌)检查和控制菌检查应采用直接接种法.

  11. 77 FR 72205 - Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for...

    Science.gov (United States)

    2012-12-05

    ... that many testing decisions are made upstream in the supply chain. Now that the CPSC accepts component... design or manufacturing process, including the sourcing of component parts,'' and the ``testing of random... supplied by another party, such as a foreign manufacturer or a supplier, then it is the voluntary certifier...

  12. Can testing of six individual muscles represent a screening approach to upper limb neuropathic conditions?

    National Research Council Canada - National Science Library

    Jepsen, Jørgen Riis

    2014-01-01

    ... is reliable and that the outcome reflects symptoms. Since this approach may appear complicated and time consuming, this study deals with the value of an examination limited to manual testing of only six muscles...

  13. Status of Wrought FeCrAl-UO2 Capsules Irradiated in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Harp, J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Core, G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linton, K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-07-01

    Candidate cladding materials for accident tolerant fuel applications require extensive testing and validation prior to commercial deployment within the nuclear power industry. One class of cladding materials, FeCrAl alloys, is currently undergoing such effort. Within these activities is a series of irradiation programs within the Advanced Test Reactor. These programs are developed to aid in commercial maturation and understand the fundamental mechanisms controlling the cladding performance during normal operation of a typical light water reactor. Three different irradiation programs are on-going; one designed as a simple proof-of-principle concept, the other to evaluate the susceptibility of FeCrAl to fuel-cladding chemical interaction, and the last to fully simulate the conditions of a pressurized water reactor experimentally. To date, nondestructive post-irradiation examination has been completed on the rodlet deemed FCA-L3 from the simple proof-of-concept irradiation program. Initial results show possible breach of the rodlet under irradiation but further studies are needed to conclusively determine whether breach has occurred and the underlying reasons for such a possible failure. Further work includes characterizing additional rodlets following irradiation.

  14. Moving on From Representativeness: Testing the Utility of the Global Drug Survey

    Science.gov (United States)

    Barratt, Monica J; Ferris, Jason A; Zahnow, Renee; Palamar, Joseph J; Maier, Larissa J; Winstock, Adam R

    2017-01-01

    A decline in response rates in traditional household surveys, combined with increased internet coverage and decreased research budgets, has resulted in increased attractiveness of web survey research designs based on purposive and voluntary opt-in sampling strategies. In the study of hidden or stigmatised behaviours, such as cannabis use, web survey methods are increasingly common. However, opt-in web surveys are often heavily criticised due to their lack of sampling frame and unknown representativeness. In this article, we outline the current state of the debate about the relevance of pursuing representativeness, the state of probability sampling methods, and the utility of non-probability, web survey methods especially for accessing hidden or minority populations. Our article has two aims: (1) to present a comprehensive description of the methodology we use at Global Drug Survey (GDS), an annual cross-sectional web survey and (2) to compare the age and sex distributions of cannabis users who voluntarily completed (a) a household survey or (b) a large web-based purposive survey (GDS), across three countries: Australia, the United States, and Switzerland. We find that within each set of country comparisons, the demographic distributions among recent cannabis users are broadly similar, demonstrating that the age and sex distributions of those who volunteer to be surveyed are not vastly different between these non-probability and probability methods. We conclude that opt-in web surveys of hard-to-reach populations are an efficient way of gaining in-depth understanding of stigmatised behaviours and are appropriate, as long as they are not used to estimate drug use prevalence of the general population. PMID:28924351

  15. Hollow microporous organic capsules

    National Research Council Canada - National Science Library

    Li, Buyi; Yang, Xinjia; Xia, Lingling; Majeed, Muhammad Irfan; Tan, Bien

    2013-01-01

    Fabrication of hollow microporous organic capsules (HMOCs) could be very useful because of their hollow and porous morphology, which combines the advantages of both microporous organic polymers and non-porous nanocapsules...

  16. Engineering Stable Hollow Capsules

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    @@ Scientists at the CAS Institute of Chemistry have been succeeded in fabricating stable hollow capsules by extending covalent layer-by-layer self-assembly(CSA)technique from 2-dimensional to 3-dimensional systems.

  17. The strange case of reproducibility versus representativeness in contextual suggestion test collections

    NARCIS (Netherlands)

    Samar, T.; Bellogin, A.; De Vries, A.P.

    2015-01-01

    The most common approach to measuring the effectiveness of Information Retrieval systems is by using test collections. The Contextual Suggestion (CS) TREC track provides an evaluation framework for systems that recommend items to users given their geographical context. The specific nature of this

  18. The strange case of reproducibility versus representativeness in contextual suggestion test collections

    NARCIS (Netherlands)

    Samar, T.; Bellogin, A.; De Vries, A.P.

    2015-01-01

    The most common approach to measuring the effectiveness of Information Retrieval systems is by using test collections. The Contextual Suggestion (CS) TREC track provides an evaluation framework for systems that recommend items to users given their geographical context. The specific nature of this tr

  19. Capsule contraction syndrome

    Directory of Open Access Journals (Sweden)

    Mesut COŞKUN

    2009-06-01

    Full Text Available Capsule contraction syndrome occurs after fibrous metaplasia of lens proteins that leads to capsular bag contraction. Excessive front capsular wrinkling is seen in capsule contraction syndrome and there is an imbalance between powers supplying capsular integrity. This situation leads to zonular weakness. Capsule contraction syndrome is associated with pseudoexfoliation, older age, uveitis, pars planitis and myotonic muscular dystrophy. In order to decrease the risk of capsule contraction syndrome, front capsulerhexis area should be open as 5.5-6 mm diameter and a curysoft intraocular lens should be used. In order to prevent lens epithelial proliferation and metaplasia, lens epithelial cells at inferior surface of front capsule should be aspirated carefully. If postoperative capsular contraction detected, front capsulotomy should be performed by Nd-YAG laser at postoperative 2 to 3 weeks. In patients that Nd-YAG laser is unsuccessful, capsular tension should be decreased by surgical microincisions. In present study, we evaluated etiology, prevention and management of capsule contraction syndrome in the light of actual literature knowledge.

  20. Testing of SMA-enabled Active Chevron Prototypes under Representative Flow Conditions

    Science.gov (United States)

    Turner, Travis L.; Cabell,Randolph H.; Cano, Roberto J.; Silcox, Richard J.

    2008-01-01

    Control of jet noise continues to be an important research topic. Exhaust-nozzle chevrons have been shown to reduce jet noise, but parametric effects are not well understood. Additionally, thrust loss due to chevrons at cruise suggests significant benefit from active chevrons. The focus of this study is development of an active chevron concept for the primary purpose of parametric studies for jet noise reduction in the laboratory and secondarily for technology development to leverage for full scale systems. The active chevron concept employed in this work consists of a laminated composite structure with embedded shape memory alloy (SMA) actuators, termed a SMA hybrid composite (SMAHC). SMA actuators are embedded on one side of the neutral axis of the structure such that thermal excitation, via joule heating, generates a moment and deflects the structure. The performance of two active chevron concepts is demonstrated in the presence of representative flow conditions. One of the concepts is shown to possess significant advantages for the proposed application and is selected for further development. Fabrication and design changes are described and shown to produce a chevron prototype that meets the performance objectives.

  1. 16 CFR 1610.61 - Reasonable and representative testing to assure compliance with the standard for the clothing...

    Science.gov (United States)

    2010-01-01

    ... Commission enforces the Standard for the Flammability of Clothing Textiles (“the Standard”), 16 CFR part 1610... assure compliance with the standard for the clothing textiles. 1610.61 Section 1610.61 Commercial... OF CLOTHING TEXTILES Interpretations and Policies § 1610.61 Reasonable and representative testing...

  2. Identifying ambiguous prostate gland contours from histology using capsule shape information and least squares curve fitting

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Rania [DigiPen Institute of Technology, Department of Computer Engineering, Redmond, WA (United States); McKenzie, Frederic D. [Old Dominion University, Department of Electrical and Computer Engineering, Norfolk, VA (United States)

    2007-12-15

    To obtain an accurate assessment of the percentage and depth of extra-capsular soft tissue removed with the prostate by the various surgical techniques in order to help surgeons in determining the appropriateness of different surgical approaches. This can be enhanced by an accurate and automated means of identifying the prostate gland contour. To facilitate 3D reconstruction and, ultimately, more accurate analyses, it is essential for us to identify the capsule boundary that separates the prostate gland tissue from its extra-capsular tissue. However, the capsule is sometimes unrecognizable due to the naturally occurring intrusion of muscle and connective tissue into the prostate gland. At these regions where the capsule disappears, its contour can be arbitrarily created with a continuing contour line based on the natural shape of the prostate. We utilize an algorithm based on a least squares curve fitting technique that uses a prostate shape equation to merge previously detected capsule parts with the shape equation to produce an approximated curve that represents the prostate capsule. We have tested our algorithm using three different shapes on 13 histologic prostate slices that are cut at different locations from the apex. The best result shows a 90% average contour match when compared to pathologist-drawn contours. We believe that automatically identifying histologic prostate contours will lead to increased objective analyses of surgical margins and extracapsular spread of cancer. Our results show that this is achievable. (orig.)

  3. Testing of breakdates in agricultural prices of selected representatives of animal production

    Directory of Open Access Journals (Sweden)

    Petra Bubáková

    2012-01-01

    Full Text Available This paper deals with an investigation of breakdates in agricultural prices. A structural break has occurred if at least one of the model parameters has changed at some date. This date is a breakdate. Ignoring structural breaks in time series can lead to serious problems with economic models of time series. The aim is to determine the number and date of the breakdates in individual time series and connect them with changes in the market and economic environment. The time series of agricultural price relating to animal production, namely the prices of pork, beef, chicken, milk and eggs, are analyzed for the period from January 1996 to December 2011. The autoregressive model (AR model of Box-Jenkins methodology and stability testing according to Quandt or Wald statistics are used for the purposes of this paper. Multiple breakdates are found in the case of eggs (September 1998, May 2004, milk (October 1999, December 2007 and chicken (October 2002, February 2005 prices. One breakdate was detected in the prices of beef (April 2002 and none in the case of pork prices. The results show the importance of multiple breakdate testing. The Quandt statistic provides one possible way of applying a multiple approach. All breakdates which were confirmed using these statistics can be associated with changes in the agri-food market and economic environment. Information about the date of changes in the time series can be used for other unbiased modelling in more complex models.

  4. 维生素E软胶囊的崩解时限与破裂试验的统计分析%Statistical analysis of rupture test and disintegration time on Vitamin E Soft Capsules

    Institute of Scientific and Technical Information of China (English)

    刘群; 王丽英; 王磊; 刘万卉

    2016-01-01

    目的:比较维生素E软胶囊的破裂试验结果与崩解时限检查结果,对两者的相关性和差异性进行统计分析。方法对34批维生素E软胶囊分别按《美国药典》39版进行破裂试验和《中国药典》2015年版进行崩解时限检查,对结果进行统计分析。结果破裂试验与崩解时限有一定的相关性,并因生产日期不同等因素而存在一定差异。结论维生素E软胶囊的破裂时间与生产日期显著性相关( P﹤0.01)。%Objective To compare the rupture test with the disintegration time on Vitamin E Soft Capsules,and find the correlations and differences between them.Methods The rupture time and disintegration time of Vitamin E Soft Cap-sules were tested by the method in USP 39 and CHP 2015.The results were analyzed by statistical method.Results There were some correlations and differences between rupture and disintegration of Vitamin E Soft Capsules. Conclusion There was a significant correlation between the rupture time and production date of Vitamin E Soft Capsules( P﹤0.01).

  5. 3D Printed Programmable Release Capsules.

    Science.gov (United States)

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients.

  6. Expanding role of capsule endoscopy in inflammatory bowel disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Capsule endoscopy has been shown to detect small bowel inflammatory changes better than any other imaging modality. Selection criteria have been optimized to increase the yield of capsule endoscopy in patients suspected to have Crohn's disease. Capsule endoscopy allows for earlier diagnosis of Crohn's disease of the small bowel and improved diagnosis of colitis in patients where it is unclear if they suffer from Crohn's or ulcerative colitis. A test capsule is available to assess for small bowel strictures and thus avoid capsule retention. A common language has been developed and a new scoring index will be added to capsule software. It is envisioned that the manner in which we treat Crohn's disease in the future will change, based on earlier diagnosis and treatment aimed at mucosal healing rather than symptom improvement.

  7. Polar tent for reduced perturbation of NIF ignition capsules

    Science.gov (United States)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  8. Regional multiaxial mechanical properties of the porcine anterior lens capsule.

    Science.gov (United States)

    David, G; Pedrigi, R M; Heistand, M R; Humphrey, J D

    2007-02-01

    The lens capsule of the eye plays fundamental biomechanical roles in both normal physiological processes and clinical interventions. There has been modest attention given to the mechanical properties of this important membrane, however, and prior studies have focused on 1-D analyses of the data. We present results that suggest that the porcine anterior lens capsule has a complex, regionally dependent, nonlinear, anisotropic behavior. Specifically, using a subdomain inverse finite element method to analyze data collected via a new biplane video-based test system, we found that the lens capsule is nearly isotropic (in-plane) near the pole but progressively stiffer in the circumferential compared to the meridional direction as one approaches the equator. Because the porcine capsule is a good model of the young human capsule, there is strong motivation to determine if similar regional variations exist in the human lens capsule for knowledge of such complexities may allow us to improve the design of surgical procedures and implants.

  9. Design of a slow-release capsule using laser drilling.

    Science.gov (United States)

    Jain, N K; Naik, S U

    1984-12-01

    Conventional hard gelatin capsules were made GI-tract resistant by formalin vapor treatment. The residual formalin content was 80 micrograms/capsule 24 h after treatment, which decreased with increased storage time. An in vitro GI-tract resistance test was performed by exposing the capsules to simulated gastric fluid for 4 h and then to simulated intestinal fluid for 4 h at 37 degrees C. The resistance was further confirmed by in vivo X-ray studies in human volunteers. Minute pores were drilled on the hardened shells of the capsules with a carbon dioxide gas laser. This permitted the slow passage of the encapsulated tetracycline hydrochloride when subjected to 0.1 M HCl in in vitro dissolution studies. In vitro drug release from these capsules followed zero-order kinetics after an initial lag period of 30 min. The factors influencing the in vitro release rate of tetracycline hydrochloride from these capsules are discussed.

  10. Reference materials and representative test materials to develop nanoparticle characterization methods: the NanoChOp project case

    Science.gov (United States)

    Roebben, Gert; Kestens, Vikram; Varga, Zoltan; Charoud-Got, Jean; Ramaye, Yannic; Gollwitzer, Christian; Bartczak, Dorota; Geißler, Daniel; Noble, James; Mazoua, Stéphane; Meeus, Nele; Corbisier, Philippe; Palmai, Marcell; Mihály, Judith; Krumrey, Michael; Davies, Julie; Resch-Genger, Ute; Kumarswami, Neelam; Minelli, Caterina; Sikora, Aneta; Goenaga-Infante, Heidi

    2015-10-01

    This paper describes the production and characteristics of the nanoparticle test materials prepared for common use in the collaborative research project NanoChOp (Chemical and optical characterisation of nanomaterials in biological systems), in casu suspensions of silica nanoparticles and CdSe/CdS/ZnS quantum dots. This paper is the first to illustrate how to assess whether nanoparticle test materials meet the requirements of a 'reference material' (ISO Guide 30:2015) or rather those of the recently defined category of 'representative test material' (ISO TS 16195:2013). The NanoChOp test materials were investigated with small-angle X-ray scattering (SAXS), dynamic light scattering (DLS) and centrifugal liquid sedimentation (CLS) to establish whether they complied with the required monomodal particle size distribution. The presence of impurities, aggregates, agglomerates and viable microorganisms in the suspensions was investigated with DLS, CLS, optical and electron microscopy and via plating on nutrient agar. Suitability of surface functionalization was investigated with attenuated total reflection Fourier transform infrared spectrometry (ATR-FTIR) and via the capacity of the nanoparticles to be fluorescently labeled or to bind antibodies. Between-unit homogeneity and stability were investigated in terms of particle size and zeta potential. This paper shows that only based on the outcome of a detailed characterization process one can raise the status of a test material to representative test material or reference material, and how this status depends on its intended use.

  11. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  12. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M., E-mail: mathias.laurie@ec.europa.eu [European Commission, Joint Research Centre, Institut für Transurane, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Fourrez, S. [THERMOCOAX SAS, Rue du Pré Neuf, 61100 Saint Georges des Groseillers (France); Fütterer, M.A.; Lapetite, J.M. [European Commission, Joint Research Centre, Institut für Transurane, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Sadli, M.; Morice, R.; Failleau, G. [Laboratoire commun de métrologie LNE-Cnam, 61 rue du Landy, F-92310 Saint-Denis (France)

    2014-05-01

    During irradiation tests at high temperature failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. As instrumentation, in particular thermocouples are considered safety-relevant both for irradiation tests and for commercial reactors, JRC and THERMOCOAX joined forces to solve this issue by performing out-of-pile tests with thermocouples mimicking the environment encountered by high temperature reactor (HTR) in-core instrumentation. The objective was to screen innovative sheathed thermocouples which would consecutively be tested under irradiation. Two such screening tests have been performed in high temperature environment (i.e. temperature in the range 1100–1150 °C) with purposely contaminated helium atmosphere (mainly CH{sub 4}, CO, CO{sub 2}, O{sub 2} impurities) representative for high temperature reactor carburizing atmospheres. The first set of thermocouples embedded in graphite (mainly conventional N type thermocouples and thermocouples with innovative sheaths) was tested in a dedicated furnace at THERMOCOAX lab with helium flushing. The second out-of-pile test at JRC with a partly different set of thermocouples replicated the original test for comparison. Performance indicators such as thermal drift, insulation resistance and loop resistance were monitored. Through these long-term screening tests the effect of several parameters were investigated: niobium sleeves, bending, diameter, sheath composition as well as the chemical environment. SEM examinations were performed to analyze local damage (bending zone, sheath). The present paper describes the two tests, sums up data collected during these tests in terms of thermocouple behavior and describes further instrumentation testing work with fixed point mini cells for qualification under irradiation.

  13. 丹参舒心胶囊微生物限度检查方法验证试验研究%Validation of microbial limit test for Danshenshuxin capsule

    Institute of Scientific and Technical Information of China (English)

    梁净; 肖华

    2011-01-01

    目的 建立丹参舒心胶囊的微生物限度检查方法,保证检验结果的正确性和可信性.方法 按2005年版一部附录微生物限度检查法的验证试验指导原则,对四家不同生产企业的丹参舒心胶囊进行微生物限度检查方法验证试验.结果 常规法试验对大肠埃希菌、白色念珠菌、黑曲霉的回收率均大于70%,而金黄色葡萄球菌、枯草芽孢杆菌则需通过薄膜过滤法试验,可有效去除其抑菌作用,使其回收率达到70%以上.控制菌检查常规法检出试验菌.结论 不同生产企业的丹参舒心胶囊对细菌的抑菌作用是不同的,丹参舒心胶囊微生物限度检查方法可采用薄膜过滤法.%Aim To establish the microbial limit test for Danshenshuxin capsule, to ensure the validity and creditability of results. Methods The methods was studied according to the guidance of the microbial limit standard from this product and the principle of the validation of microbiological test in “Chinese Pharmacopoeia”( 2005 )in four different factories of Danshenshuxin capsule. Results With routine test the rate of recovery of escherichia coli, candida albicans and aspergillus niger was over over 70%, but the rate of recovery of staphylococcus aureus and bacillus subtilis was over 70% only by filtration membrane. Test organism was obtained by controlled bacteria detection test. Conclusion Danshenshuxin capsules produced in different factories are different in eliminating bacteriostasis effectively.The method of filtration membrane can be used as microbiological test for Danshenshuxin capsule.

  14. VALIDATION METHOD USED FOR MICROBIAL LIMIT TEST OF QILIQIANGXIN CAPSULES%芪苈强心胶囊微生物限度检查方法学验证

    Institute of Scientific and Technical Information of China (English)

    王刚; 李素霞; 李喆; 周莹君; 范文成; 王丽环

    2013-01-01

    目的 建立芪苈强心胶囊的微生物限度检查法.方法 采用微生物限度检查方法,对该胶囊微生物检验方法进行验证.结果 混入芪苈强心胶囊中的枯草芽孢杆菌、金黄色葡萄球菌、白色念珠菌和黑曲霉用常规检验法细菌回收率均比较低,表现出一定抑菌作用,但大肠埃希菌回收率符合要求.混入该胶囊中的枯草芽孢杆菌、金黄色葡萄球菌、白色念珠菌和黑曲霉采用稀释法检测,其回收率明显提高.结论 该药物胶囊对细菌和真菌均有一定的抑制作用,可以通过培养基稀释法来消除.%Objective To establish the method to determine the microbial limit tests for Qiliqiangxin Capsules.Methods By using validation method,the microbial limit test for the capsules was validated.Results Using the conventional test method,the bacterial recovery rates of the Bacillus subtilis,Staphylococcus aureus,Candida albicans,and Aspergillus niger were lower.The recovery rates of the Escherichia coli could meet the requirements.The Bacillus subtilis,Staphylococcus aureus,Candida albicans and Aspergillus niger could be tested by culture medium dilution method,the recovery rate has been significantly improved.Conclusion Qiliqiangxin Capsules showed inhibition effect on the bacteria and fungus.The effect could be eliminated by culture medium dilution method.

  15. Multicomposite ultrathin capsules for sustained ocular delivery of ciprofloxacin hydrochloride.

    Science.gov (United States)

    Bhadra, Dipankar; Gupta, Girish; Bhadra, Sulekha; Umamaheshwari, R B; Jain, Narendra

    2004-07-16

    The present work is intended to develop a sustained bioadhesive drug delivery system for delivery of Ciprofloxacin Hydrochloride in Cul-de-Sac for sustained and effective antimicrobial chemotherapy. For this, ultrathin multicomposite capsular systems were selected. Multicomposite ultrathin capsules are molecular assemblies of tailored architecture having layer-by-layer adsorption of oppositely charged macromolecules onto colloidal particles. In the present study colloidal calcium phosphate core and gluateraldehyde fixed RBCs were used as core on which alginate (-vely charged) and polyallylamine hydrochloride (+vely charged) polyelectrolyte coating was deposited alternatively upto 10th layer. The coating in each subsequent layer was determined by changes in zeta potential. Ciprofloxacin hydrochloride was loaded in the capsules by incubation with the capsules suspended in phosphate buffer saline pH 7.4. The cores of the capsules were then removed by treatment with 0.1N HCl for calcium phosphate core and by sodium hypochlorite for RBC cored capsules. The hollow ciprofloxacin HCl loaded capsules were the evaluated in-vitro for pattern of layer-by-layer drug loading, drug release, stability at various temperatures and ionic concentrations and corneal retention. The core removal process was found to have minimal effects on drug loading in capsules. The drug loading was found to be higher for RBC cored hollow capsules and hence release rate was lower as compared to calcium cored hollow capsules. Draize test for corneal irritancy proved that the capsules were not irritating. The capsules were found to deliver the ciprofloxacin in cul-de-sac of rabbit's eyes for prolonged period. Based on corneal retention studies and tear drug concentration, the capsules can be considered for suitable and safe use for sustained ocular delivery of drugs.

  16. A commentary on 'generally representative is representative of none: pitfalls of IQ test standardization in multicultural settings' by A.B. Shuttleworth-Edwards.

    Science.gov (United States)

    Sunderaraman, Preeti; Zahodne, Laura B; Manly, Jennifer J

    2016-10-01

    We offer an appraisal of Professor Shuttleworth-Edwards's commentary (2016) on the extraordinary challenges of assessment of cognitive function in a culturally, educationally, racially, and linguistically diverse population. First, we discuss the purpose of using intelligence tests in South Africa and beyond in order to clarify the reference group on which norms will be based. Next, we discuss the psychometric consequences of Pearson's decisions to not adapt their measure of intellectual functioning to the cultural background of the majority of South Africans, and to use a population-matched normative sample in which the disadvantaged group is in the majority. We echo Professor Shuttleworth-Edwards's call for large-scale empirical studies of cognitive test performance in a multicultural context. We conclude the article by urging the entire community of neuropsychologists to hold test companies accountable to strict, ethical, and comprehensive standards for production of accurate and appropriate measurement of cognitive function.

  17. 甲磺酸达比加群酯胶囊微生物限度检查方法的建立%The establishment of microbial limit test method of Dabigatran Etexilate Mesylate Capsules

    Institute of Scientific and Technical Information of China (English)

    贾雷; 王嘉南

    2014-01-01

    Objective To establish a method of microbial limit test for Dabigatran Etexilate Mesylate Capsules. Meth-ods Validation of microbiological limit tests according to Chinese Pharmacopoeia edition 2010. Results Dabigatran Etex-ilate Mesylate Capsules has strong inhibiting effect on Bacillus subtilis and Staphylococcus aureus in bacterium. Conclusion The membrane filtration method was used in the test of bacterium. The routine method was used in the test of mold and yeasts. The routine method was used in the test of pathogenic bacterium.%目的:探讨建立甲磺酸达比加群酯胶囊的微生物限度检查的方法。方法依据《中国药典》2010年版(二部)收载的微生物限度检查法应用指导原则进行方法学验证试验。结果试验表明甲磺酸达比加群酯胶囊对枯草芽孢杆菌和金黄色葡萄球菌具有较强的抑制作用。结论推荐采用薄膜过滤法进行本品的细菌计数;采用常规检验方法进行真菌及酵母菌计数和控制菌检查。

  18. Multiple Irradiation Capsule Experiment (MICE)-3B Irradiation Test of Space Fuel Specimens in the Advanced Test Reactor (ATR) - Close Out Documentation for Naval Reactors (NR) Information

    Energy Technology Data Exchange (ETDEWEB)

    M. Chen; CM Regan; D. Noe

    2006-01-09

    Few data exist for UO{sub 2} or UN within the notional design space for the Prometheus-1 reactor (low fission rate, high temperature, long duration). As such, basic testing is required to validate predictions (and in some cases determine) performance aspects of these fuels. Therefore, the MICE-3B test of UO{sub 2} pellets was designed to provide data on gas release, unrestrained swelling, and restrained swelling at the upper range of fission rates expected for a space reactor. These data would be compared with model predictions and used to determine adequacy of a space reactor design basis relative to fission gas release and swelling of UO{sub 2} fuel and to assess potential pellet-clad interactions. A primary goal of an irradiation test for UN fuel was to assess performance issues currently associated with this fuel type such as gas release, swelling and transient performance. Information learned from this effort may have enabled use of UN fuel for future applications.

  19. Wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    A Mata; J Llach; JM Bordas

    2008-01-01

    Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without external wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleeding, Crohn's disease and gastrointestinal polyposis syndromes with promising results. Studies on other pathologies (I.e. Small bowel tumour, celiac disease) are under evaluation to define the role of this technique.

  20. Intestinal preparation prior to capsule endoscopy administration

    Institute of Scientific and Technical Information of China (English)

    Vicente Pons Beltrán; Cristina Carretero; Bego(n)a Gonzalez-Suárez; I(n)aqui Fernández-Urien; Miguel Mu(n)oz Navas

    2008-01-01

    In order to have an adequate view of the whole small intestine during capsule endoscopy,the preparation recommended consists of a clear liquid diet and an overnight fast.However,visualization of the small bowel during video capsule endoscopy can be impaired by intestinal contents.To improve mucosal visualization,some authors have evaluated different regimens of preparation.There is no consensus about the necessity of intestinal preparation for capsule endoscopy and it should be interesting to develop adequate guidelines to improve its efficacy and tolerability.Moreover,the effect of preparation type (purgative) on intestinal transit time is not clear.Since a bowel preparation cannot definitively improve its visibility (and theoretically the yield of the test),it is not routinely recommended.

  1. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  2. Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules

    OpenAIRE

    O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy; Ashley, Kevin

    2014-01-01

    An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were ...

  3. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    Energy Technology Data Exchange (ETDEWEB)

    Laurie, M. [European Commission, Joint Research Centre, Inst. for Energy, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Fourrez, S. [THERMOCOAX SAS, BP 26, Planquivon, F-61438 Flers Cedex (France); Fuetterer, M. A.; Lapetite, J. M. [European Commission, Joint Research Centre, Inst. for Energy, P.O. Box 2, NL-1755 ZG Petten (Netherlands)

    2011-07-01

    During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remedy this problem, out-of-pile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of thermocouples embedded in graphite (mainly conventional Type N thermocouples and thermocouples with innovative sheaths) in a dedicated furnace with helium flushing. Performance indicators such as thermal drift, insulation and loop resistance were monitored and compared to those from conventional Type N thermocouples. Several parameters were investigated: niobium sleeves, bending, thickness, sheath composition, temperature as well as the chemical environment. After the tests, Scanning Electron Microscopy (SEM) examinations were performed to analyze possible local damage in wires and in the sheath. The present paper describes the two experiments, summarizes results and outlines further work, in particular to further analyze the findings and to select suitable thermocouples for qualification under irradiation. (authors)

  4. Management of adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Stupay KL

    2015-08-01

    Full Text Available Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive criteria for diagnosis make evaluating treatment modalities difficult. Many treatment methods have been reported, most with some success, but few have been proved to alter the natural course of this disease. Most afflicted patients will achieve acceptable shoulder function without surgery. Those who remain debilitated after 8–12 months are reasonable candidates for invasive treatments. Here, the various treatment methods and the data to support their use are reviewed. Keywords: frozen shoulder, stiff shoulder, periarthritis, painful shoulder 

  5. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs.

  6. Capsule-train stability

    Science.gov (United States)

    Bryngelson, Spencer H.; Freund, Jonathan B.

    2016-07-01

    Elastic capsules flowing in small enough tubes, such as red blood cells in capillaries, are well known to line up into regular single-file trains. The stability of such trains in somewhat wider channels, where this organization is not observed, is studied in a two-dimensional model system that includes full coupling between the viscous flow and suspended capsules. A diverse set of linearly amplifying disturbances, both long-time asymptotic (modal) and transient (nonmodal) perturbations, is identified and analyzed. These have a range of amplification rates and their corresponding forms are wavelike, typically dominated by one of five principal perturbation classes: longitudinal and transverse translations, tilts, and symmetric and asymmetric shape distortions. Finite-amplitude transiently amplifying perturbations are shown to provide a mechanism that can bypass slower asymptotic modal linear growth and precipitate the onset of nonlinear effects. Direct numerical simulations are used to verify the linear analysis and track the subsequent transition of the regular capsule trains into an apparently chaotic flow.

  7. GGE biplot analysis of yield stability and test location representativeness in proso millet (Panicum miliaceum L.) genotypes

    Institute of Scientific and Technical Information of China (English)

    ZHANG Pan-pan; ZHENG Dian-feng; FENG Bai-li; SONG Hui; KE Xi-wang; JIN Xi-jun; YIN Li-hua; LIU Yang; QU Yang; SU Wang; FENG Nai-jie

    2016-01-01

    The experiments were conducted for three consecutive years across 14 locations using 9 non-waxy proso milet genotypes and 16 locations using 7 waxy proso milet genotypes in China. The objectives of this study were to analyze yield stability and adaptability of proso milets and to evaluate the discrimination and representativeness of locations by analysis of vari-ance (ANOVA) and genotype and genotype by environment interaction (GGE) biplot methods. Grain yields of proso milet genotypes were signiifcantly inlfuenced by environment (E), genotype (G) and their interaction (G×E) (P<0.1%). G×E inter-action effect was six times higher than G effect in non-waxy group and seven times in waxy group. N04-339 in non-waxy and Neimi 6 (NM6) in waxy showed higher grain yields and stability compared with other genotypes. Also, Neimi 9 (NM9, a non-waxy cultivar) and 90322-2-33 (a waxy cultivar) showed higher adaptability in 7 and in 11 locations, respectively. For non-waxy, Dalat, Inner Mongolia (E2) and Wuzhai, Shanxi (E5) were the best sites among al the locations for maximizing the variance among candidate cultivars, and Yanchi, Ningxia (E10) had the best representativeness. Wuzhai, Shanxi (e9) and Yanchi, Ningxia (e14) were the best representative locations, and Baicheng, Jilin (e2) was better discriminating location than others for waxy genotypes. Based on our results, E10 and e14 have enhanced efifciency and accuracy for non-waxy genotypes and waxy genotypes selection, respectively in national regional test of proso milet varieties.

  8. Analyses of copper from a prototype capsule 5 and 6; Analyser av koppar fraan prototypkapsel 5 och 6

    Energy Technology Data Exchange (ETDEWEB)

    Taxen, Claes; Lundholm, Martin; Persson, Dan; Jakobsson, Dan; Sedlakova, Miroslava; Randelius, Mats; Karlsson, Oskar; Rydgren, Pontus; Kimab, Swerea

    2012-12-15

    'Prototype' is a series of experiments where SKB, the Swedish Nuclear Fuel and Waste Management Co, expose the full scale copper canisters under conditions intended to be representative of a repository for spent nuclear fuel, however, without radioactivity (SKB 2012) . Copper from one of these installations, deposition 5, has been studied for corrosion . Samples were also taken from the capsule that had been exposed in deposition 6. Drill cores across the capsule wall has been documented regarding microstructure. All samples have been exposed for about seven years in the prototype repository. Studies carried out leads to the following conclusions: Regarding the ring on top of the capsule from the deposition 5; There are local corrosion with a depth of 3-5 microns. The general or uniform corrosion that has occurred can not be quantified. The relatively sharp traces of processing of the material before exposure indicates that the general corrosion was minor. Small amounts of corrosion product has been detected in surface analysis. The surface profile on the copper surface, aside from the grooves after processing and areas of local corrosion, are relatively even. Metallographic examination of cross section shows no tendency to pitting or intergranular corrosion. Analysis for hydrogen by melting a quantity of metal does not show any increased hydrogen content. Regarding the material of the capsule from the deposition 6: The capsule has not been specifically tested for corrosion. Cross sections of drill cores through the copper canister has been documented and metallo graphically exhibits nothing remarkable.

  9. Improving ICF implosion performance with alternative capsule supports

    Science.gov (United States)

    Weber, C. R.; Casey, D. T.; Clark, D. S.; Hammel, B. A.; MacPhee, A.; Milovich, J.; Martinez, D.; Robey, H. F.; Smalyuk, V. A.; Stadermann, M.; Amendt, P.; Bhandarkar, S.; Chang, B.; Choate, C.; Crippen, J.; Felker, S. J.; Field, J. E.; Haan, S. W.; Johnson, S.; Kroll, J. J.; Landen, O. L.; Marinak, M.; Mcinnis, M.; Nikroo, A.; Rice, N.; Sepke, S. M.

    2017-05-01

    The thin membrane that holds the capsule in-place in the hohlraum is recognized as one of the most significant contributors to reduced performance in indirect drive inertial confinement fusion (ICF) experiments on the National Ignition Facility. This membrane, known as the "tent," seeds a perturbation that is amplified by Rayleigh-Taylor and can rupture the capsule. A less damaging capsule support mechanism is under development. Possible alternatives include the micron-scale rods spanning the hohlraum width and supporting either the capsule or stiffening the fill-tube, a larger fill-tube to both fill and support the capsule, or a low-density foam layer that protects the capsule from the tent impact. Experiments are testing these support features to measure their imprint on the capsule. These experiments are revealing unexpected aspects about perturbation development in indirect drive ICF, such as the importance of shadows coming from bright spots in the hohlraum. Two dimensional and 3D models are used to explain these features and assess the impact on implosion performance. Experiments and modeling suggest that the fill-tube supported by a perpendicular rod can mount the capsule without any additional perturbation beyond that of the fill tube.

  10. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  11. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  12. Desenvolvimento e validação do ensaio de dissolução para captopril em cápsulas magistrais por CLAE Development and validation of dissolution test for captopril in capsules by HPLC

    Directory of Open Access Journals (Sweden)

    Roberta de Cássia Pimentel Azevedo

    2008-06-01

    Full Text Available O captopril é um fármaco anti-hipertensivo e vasodilatador utilizado na insuficiência cardíaca congestiva e encontra-se disponível, no mercado brasileiro, sob as formas de comprimidos e cápsulas, sendo estas manipuladas em farmácias. O objetivo deste estudo foi validar o procedimento de dissolução e o método de análise. A avaliação do perfil de dissolução do captopril na forma farmacêutica cápsulas magistrais quando submetidas a diferentes condições de pH, aparatos, velocidades de agitação do meio de dissolução e métodos para quantificação foram alvo deste estudo. As concentrações do fármaco no meio foram determinadas por cromatografia líquida e espectrofotometria. Os resultados mostraram que o método cromatográfico foi o mais adequado para avaliação de captopril na forma farmacêutica cápsulas, enquanto o método espectrofotométrico (recomendado pelas Farmacopéias Brasileira e Americana apresentou baixa especificidade. O procedimento de dissolução nas condições estabelecidas foi preciso, exato e seletivo. O método foi linear. Com base nos resultados obtidos as condições do teste de dissolução para cápsulas foram o uso de HCl 0,01 M (900 mL, 37 ºC ± 0,5 ºC, aparato cesta, 50 rpm, tempo de coleta (20 minutos e quantificação pelo método cromatográfico. Todas as cápsulas apresentaram resultados satisfatórios nos testes de qualidade a que foram submetidas.Captopril is an anti-hypertensive and vasodilator agent utilized in the congestive cardiac insufficiency and it can be commercially found in Brazil in the form of tablets and compounded capsules. The aim of this study was to evaluate the dissolution profile of captopril in capsules dosage obtained from compounded pharmacies, when submitted to different conditions of pH, apparatus, stirring speed of dissolution medium and analytical method, as well the validation of the dissolution procedure and of the method of analysis. The drug

  13. Capsule endoscopy in celiac disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endoscopy; however, indications are expanding and a small number of preliminary reports have been presented concerning the role of video capsule endoscopy in the diagnosis of celiac disease. The purpose of this review is to update the current knowledge and to hypothesize on future perspectives of the use of video capsule endoscopy in patients with celiac disease.

  14. Optimal Design of Capsule Transporting Pipeline carrying Spherical Capsules

    Science.gov (United States)

    Asim, Taimoor; Mishra, Rakesh; Ubbi, Kuldip

    2012-05-01

    A capsule pipeline transports material or cargo in capsules propelled by fluid flowing through a pipeline. The cargo may either be contained in capsules (such as wheat enclosed inside sealed cylindrical containers), or may itself be the capsules (such as coal compressed into the shape of a cylinder or sphere). As the concept of capsule transportation is relatively new, the capsule pipelines need to be designed optimally for commercial viability. An optimal design of such a pipeline would have minimum pressure drop due to the presence of the solid medium in the pipeline, which corresponds to minimum head loss and hence minimum pumping power required to drive the capsules and the transporting fluid. The total cost for the manufacturing and maintenance of such pipelines is yet another important variable that needs to be considered for the widespread commercial acceptance of capsule transporting pipelines. To address this, the optimisation technique presented here is based on the least-cost principle. Pressure drop relationships have been incorporated to calculate the pumping requirements for the system. The maintenance and manufacturing costs have been computed separately to analyse their effects on the optimisation process. A design example has been included to show the usage of the model presented. The results indicate that for a specific throughput, there exists an optimum diameter of the pipeline for which the total cost for the piping system is at its minimum.

  15. Structural analysis and design optimization of double shell system for fuel irradiation capsule

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. S.; Choi, Y. J.; Choi, M. H.; Rhu, C. H.; Go, J. H.; Hong, S. J.; Lee, H. C. [Chungnam National Univ., Taejeon (Korea)

    2001-04-01

    During irradiation tests, the fuel capsule expect that the high temperature will be occur. Thus, to estimate the structural integrity of fuel capsule during irradiation tests, it is needed to perform structural analysis and to obtain the information of mechanical characteristics for the system. In this study, the structure analysis of the circular capsule is performed using the finite element analysis program, ANSYS and analysis calculation. To obtain the mechanical characteristics of the circular capsule structure such as stresses, critical buckling loads and natural frequencies et al. the static nd model analysis are conducted. The effects of various wall thicknesses of capsule outer tube and support tube for circular capsule are obtained. Also, the effects of boundary conditions and principal materials of the fuel capsule on the structural behavior are investigated. The FE results are compared with the analysis results in case of possible. 13 refs., 34 figs., 10 tabs. (Author)

  16. Magnetism in metal-organic capsules

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, Jerry L.; Brechin, Euan K; Dalgarno, Scott J.; Inglis, Ross; Jones, Leigh F.; Mossine, Andrew; Paterson, Martin J.; Power, Nicholas P.; Teat, Simon J.

    2010-01-07

    Nickel and cobalt seamed metal-organic capsules have been isolated and studied using structural, magnetic and computational approaches. Antiferromagnetic exchange in the Ni capsule results from coordination environments enforced by the capsule framework.

  17. Magnetism in metal-organic capsules

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, Jerry L.; Brechin, Euan K; Dalgarno, Scott J.; Inglis, Ross; Jones, Leigh F.; Mossine, Andrew; Paterson, Martin J.; Power, Nicholas P.; Teat, Simon J.

    2010-01-07

    Nickel and cobalt seamed metal-organic capsules have been isolated and studied using structural, magnetic and computational approaches. Antiferromagnetic exchange in the Ni capsule results from coordination environments enforced by the capsule framework.

  18. Testing the Paradigm that Ultra-Luminous X-Ray Sources as a Class Represent Accreting Intermediate

    Science.gov (United States)

    Berghea, C. T.; Weaver, K. A.; Colbert, E. J. M.; Roberts, T. P.

    2008-01-01

    To test the idea that ultraluminous X-ray sources (ULXs) in external galaxies represent a class of accreting Intermediate-Mass Black Holes (IMBHs), we have undertaken a program to identify ULXs and a lower luminosity X-ray comparison sample with the highest quality data in the Chandra archive. We establish a general property of ULXs that the most X-ray luminous objects possess the fattest X-ray spectra (in the Chandra band pass). No prior sample studies have established the general hardening of ULX spectra with luminosity. This hardening occurs at the highest luminosities (absorbed luminosity > or equals 5x10(exp 39) ergs/s) and is in line with recent models arguing that ULXs are actually stellar-mass black holes. From spectral modeling, we show that the evidence originally taken to mean that ULXs are IMBHs - i.e., the "simple IMBH model" - is nowhere near as compelling when a large sample of ULXs is looked at properly. During the last couple of years, XMM-Newton spectroscopy of ULXs has to some large extent begun to negate the simple IMBH model based on fewer objects. We confirm and expand these results, which validates the XMM-Newton work in a broader sense with independent X-ray data. We find (1) that cool disk components are present with roughly equal probability and total flux fraction for any given ULX, regardless of luminosity, and (2) that cool disk components extend below the standard ULX luminosity cutoff of 10(exp 39) ergs/s, down to our sample limit of 10(exp 38:3) ergs/s. The fact that cool disk components are not correlated with luminosity damages the argument that cool disks indicate IMBHs in ULXs, for which a strong statistical support was never made.

  19. Safety and Its Countermeasures for the Test of Simulated Environment of the Manned Space Capsule%载人航天空间环境模拟试验安全与措施

    Institute of Scientific and Technical Information of China (English)

    陈金明; 黄本诚

    2001-01-01

    Test of simulated environment of the manned space capsule is very risky. In o rder to ensure the safety of the spacemen during pilot test, the equipment used in simulation test must be systematically checked and perfected. All the staff e ngaged the test must be well trained. The flowchart of the test must be worked o ut in detail, and strictly organized and managed. In this paper, the technical r equirements of the test facilities, the training courses involved in the pilot t est, and countermeasures in the organization and management are emphatically int roduced.%载人航天空间环境模拟试验极其危险,为了确保参试航天员的生命安全,必须对模拟试 验设备进行系统配套与完善,同时必须事先进行人员培训、制定详细的试验流程,进行严密 的组织管理。为此,重点介绍了为确保参试航天员的安全,对试验设备所提出的技术要求, 以及试验所涉及的训练、演习、试验组织管理等方面的安全措施。

  20. Establishment of dissolution curves test method of Ribavirin capsules and investigation with domestic ribavirin capsules of dissolution behavior%利巴韦林胶囊溶出曲线测定方法的建立及国产利巴韦林胶囊溶出行为的考察

    Institute of Scientific and Technical Information of China (English)

    杨洪淼; 蔺娟; 闵祺; 廖海明; 范慧红

    2015-01-01

    Objective To establish the dissolution curves test method of Ribavirin capsules, and investigate dissolution behavior of domestic Ribavirin capsules.To provide experimental basis for generic drugs quality consistency evaluation.Methods According to the first dissolution method (basket method)stated in appendix Ⅹof Chinese Pharmacopeia(2010 edition),the rotation speed was 50 r/min with dissolution medium volume of 900 mL.The dissolution profiles of Ribavirin capsules in four different mediums( pH 1.2 hydrochloric acid solution,pH 4.5 acetic buffer,pH 6.8 phosphate buffer and water) were determined by HPLC.The determination was performed on C18 column with mobile phase consisted of 4 g/L sodium dihydrogen phosphate solution(pH adjusted to 5.0 ±0.05 using 5% sodium hydroxide solution)-acetonitrile(98:2)at the flow rate of 1.0 mL/min.The detection wavelength was 225 nm,and sample size was 10μL.Results The linear range of ribavirin was 2.5-200μg/mL(r=1).RSD of precision and stability tests were lower than 0.5%.The average recoveries were 101.3%, 100.7%, 100.2%, 100.4% in four mediums.Dissolution behavior of capsules can be more consistent and rapid dissolution in pH4.5 and pH6.8 mediums.But they were quite different in pH1.2 and water mediums, and some of their average dissolution at 15 min could not reach 85%.Conclusion This method is accurate and reliable.There is a difference between domestic Ribavirin capsules dissolution behavior, and the formulation processes have room for improvement.%目的:建立利巴韦林胶囊溶出曲线测定方法,考察国内利巴韦林胶囊溶出行为,为该品种仿制药质量一致性评价工作提供实验依据。方法采用《中国药典》2010年版(二部)附录Ⅹ C第一法(篮法),转速50 r/min,分别以pH 1.2盐酸溶液、pH 4.5醋酸盐缓冲液、pH 6.8磷酸盐缓冲液、水为溶出介质,溶出介质体积900 mL,于不同时间点取样测定并绘制4种溶出介质下的溶出

  1. The mechanical properties of the human hip capsule ligaments.

    Science.gov (United States)

    Hewitt, John D; Glisson, Richard R; Guilak, Farshid; Vail, T Parker

    2002-01-01

    The human hip capsule is adapted to facilitate upright posture, joint stability, and ambulation, yet it routinely is excised in hip surgery without a full understanding of its mechanical contributions. The objective of this study was to provide information about the mechanical properties of the ligaments that form the hip capsule. Cadaver bone-ligament-bone specimens of the iliofemoral, ischiofemoral, and femoral arcuate ligaments were tested to failure in tension. The hip capsule was found to be an inhomogeneous structure and should be recognized as being composed of discrete constituent ligaments. The anterior ligaments, consisting of the 2 arms of the iliofemoral ligament, were much stronger than the posterior ischiofemoral ligament, withstanding greater force at failure and exhibiting greater stiffness. Knowledge of the anatomy and mechanical properties of the capsule may help the hip surgeon choose an appropriate surgical approach or repair strategy.

  2. Multiaxial mechanical behavior of the porcine anterior lens capsule.

    Science.gov (United States)

    Heistand, M R; Pedrigi, R M; Delange, S L; Dziezyc, J; Humphrey, J D

    2005-11-01

    The biomechanics of the lens capsule of the eye is important both in physiologic processes such as accommodation and clinical treatments such as cataract surgery. Although the lens capsule experiences multiaxial stresses in vivo, there have been no measurements of its multiaxial properties or possible regional heterogeneities. Rather all prior mechanical data have come from 1-D pressure-volume or uniaxial force-length tests. Here, we report a new experimental approach to study in situ the regional, multiaxial mechanical behavior of the lens capsule. Moreover, we report multiaxial data suggesting that the porcine anterior lens capsule exhibits a typical nonlinear pseudo-elastic behavior over finite strains, that the in situ state is pre-stressed multi-axially, and that the meridional and circumferential directions are principal directions of strain, which is nearly equi-biaxial at the pole but less so towards the equator. Such data are fundamental to much needed constitutive formulations.

  3. Squeezing through: capsule or bubble?

    CERN Document Server

    Dawson, Geoffrey

    2013-01-01

    In this fluid dynamics video, we compare the deformation of two flexible particles as they propagate through a sudden constriction of a liquid filled channel under constant-flux flow: a gas bubble, and a capsule formed by encapsulating a liquid droplet in a cross-linked polymeric membrane. Both bubble and capsule adopt highly contorted configurations as they squeeze through the constriction, exhibit broadly similar features over a wide range of flow rates, and rupture for sufficiently high flow rates. However, at flow rates prior to rupture, certain features of the deformation allow bubble and capsule to be distinguished: bubbles exhibit a tip-streaming singularity associated with critical thinning of the rear of the bubble, while the capsule membrane wrinkles under large compressive stresses induced by the constriction.

  4. Internalization of Red Blood Cell-Mimicking Hydrogel Capsules with pH-Triggered Shape Responses

    Science.gov (United States)

    2015-01-01

    We report on naturally inspired hydrogel capsules with pH-induced transitions from discoids to oblate ellipsoids and their interactions with cells. We integrate characteristics of erythrocytes such as discoidal shape, hollow structure, and elasticity with reversible pH-responsiveness of poly(methacrylic acid) (PMAA) to design a new type of drug delivery carrier to be potentially triggered by chemical stimuli in the tumor lesion. The capsules are fabricated from cross-linked PMAA multilayers using sacrificial discoid silicon templates. The degree of capsule shape transition is controlled by the pH-tuned volume change, which in turn is regulated by the capsule wall composition. The (PMAA)15 capsules undergo a dramatic 24-fold volume change, while a moderate 2.3-fold volume variation is observed for more rigid PMAA–(poly(N-vinylpyrrolidone) (PMAA–PVPON)5 capsules when solution pH is varied between 7.4 and 4. Despite that both types of capsules exhibit discoid-to-oblate ellipsoid transitions, a 3-fold greater swelling in radial dimensions is found for one-component systems due to a greater degree of the circular face bulging. We also show that (PMAA–PVPON)5 discoidal capsules interact differently with J774A.1 macrophages, HMVEC endothelial cells, and 4T1 breast cancer cells. The discoidal capsules show 60% lower internalization as compared to spherical capsules. Finally, hydrogel capsules demonstrate a 2-fold decrease in size upon internalization. These capsules represent a unique example of elastic hydrogel discoids capable of pH-induced drastic and reversible variations in aspect ratios. Considering the RBC-mimicking shape, their dimensions, and their capability to undergo pH-triggered intracellular responses, the hydrogel capsules demonstrate considerable potential as novel carriers in shape-regulated transport and cellular uptake. PMID:24848786

  5. Analytical Quality check of oil based blend in Flaxilip capsule

    Directory of Open Access Journals (Sweden)

    Rajashree Rane

    2014-12-01

    Full Text Available Analysis of capsules containing blend in the powder form is easy, but it is bit difficult to analyse the soft gelatin capsule containing oil based blend. The purpose of this study was to develop test parameters to determine and supervise the quality of such herbal capsule formulation. Five different lots of soft gelatin Flaxilip capsule containing Linseed oil, Guggulu processed with linseed oil, Garlic oil, Fenugreek oil along with Soyabean oil as an excipient , were selected for the study. All the five lots were subjected to general capsule tests such as determination of average weight and disintegration time. Results obtained were around 1.3500g and 10minutes respectively. Specific test parameters applicable for oils like specific gravity, refractive index, acid value, peroxide value, saponification value, iodine value were applied quantitatively for quality evaluation. Standardised suitable classical methods were applied. Results in all the five lots were found to be well within inhouse limit. All the samples were subjected to heavy metals and microbiological testing. Compliance of corresponding findings with the standard pharmacopoeial guidelines assure the safe intake of the drug. For getting the better effect, the Guggulu that is Commiphora mukul used in the formulation was processed with linseed oil. Its presence was confirmed by carrying out HPTLC for E and Z guggulu sterone. Resemblance of spots at Rf ranging from 0.36 to 0.38 and 0.43 to 0.45 in Toluene : Acetone (9:1 system showed the presence of gugulu in blends of all the lots. Hence by applying all these test parameters one can ensure the quality of the soft gelatin ayurvedic capsule formulation containing oily base like in Flaxilip capsule.

  6. Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

    OpenAIRE

    LAURIE Mathias; FOURREZ Stéphane; FUETTERER Michael; LAPETITE Jean-Marc; SADLI M.; MORICE Ronan; FAILLEAU G

    2013-01-01

    During irradiation tests at high temperature failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. As instrumentation, in particular thermocouples are considered safety-relevant both for irradiation tests and for commercial reactors, JRC and THERMOCOAX joined forces to solve this issue by performing out-of-pile tests with thermocouples mimicking the environment encountered by high temperature reactor (HTR) in-core instrumentation. The objective was to screen innova...

  7. Pickering Emulsion-Based Marbles for Cellular Capsules

    Directory of Open Access Journals (Sweden)

    Guangzhao Zhang

    2016-07-01

    Full Text Available The biodegradable cellular capsule, being prepared from simple vaporization of liquid marbles, is an ideal vehicle for the potential application of drug encapsulation and release. This paper reports the fabrication of cellular capsules via facile vaporization of Pickering emulsion marbles in an ambient atmosphere. Stable Pickering emulsion (water in oil was prepared while utilizing dichloromethane (containing poly(l-lactic acid and partially hydrophobic silica particles as oil phase and stabilizing agents respectively. Then, the Pickering emulsion marbles were formed by dropping emulsion into a petri dish containing silica particles with a syringe followed by rolling. The cellular capsules were finally obtained after the complete vaporization of both oil and water phases. The technique of scanning electron microscope (SEM was employed to research the microstructure and surface morphology of the prepared capsules and the results showed the cellular structure as expected. An in vitro drug release test was implemented which showed a sustained release property of the prepared cellular capsules. In addition, the use of biodegradable poly(l-lactic acid and the biocompatible silica particles also made the fabricated cellular capsules of great potential in the application of sustained drug release.

  8. Testing the validity of a Cd soil quality standard in representative Mediterranean agricultural soils under an accumulator crop

    Energy Technology Data Exchange (ETDEWEB)

    Recatala, L., E-mail: luis.recatala@uv.es [Departamento de Planificacion Territorial, Centro de Investigaciones sobre Desertificacion-CIDE (CSIC-Universitat de Valencia-Generalitat Valenciana), Cami de la Marjal S/N, 46470 Albal (Valencia) (Spain); Sanchez, J. [Departamento de Planificacion Territorial, Centro de Investigaciones sobre Desertificacion-CIDE (CSIC-Universitat de Valencia-Generalitat Valenciana), Cami de la Marjal S/N, 46470 Albal (Valencia) (Spain); Arbelo, C. [Departamento de Edafologia y Geologia, Facultad de Biologia, Universidad de La Laguna, 38206 La Laguna (Tenerife), Islas Canarias (Spain); Sacristan, D. [Departamento de Planificacion Territorial, Centro de Investigaciones sobre Desertificacion-CIDE (CSIC-Universitat de Valencia-Generalitat Valenciana), Cami de la Marjal S/N, 46470 Albal (Valencia) (Spain)

    2010-12-01

    The validity of a quality standard for cadmium (Cd) in representative agricultural Mediterranean soils under an accumulator crop (Lactuca sativa L.) is evaluated in this work considering both its effect on the crop growth (biomass production) and the metal accumulation in the edible part of the plant. Four soils with different properties relevant to regulate the behaviour of heavy metals were selected from the Valencian Region, a representative area of the European Mediterranean Region. For all soils, the effective concentration of added Cd causing 50% inhibition (EC{sub 50}) on the biomass production was much higher than the minimum legal concentration used to declare soils as contaminated by cadmium, i.e. 100 times the baseline value for Cd, in Spain (Spanish Royal Decree 9/2005). As expected, Cd toxicity in the crop was higher in the soils having less carbonate content. On the other hand, for all soils, from the second dose on, which represents 10-times the baseline value for Cd, the metal content in crops exceeded the maximum level established for leaf crops by the European legislation (Regulation EC no. 466/2001). Soil salinity and coarse textures make the accumulation of Cd in the edible part of the plant easier. Therefore, the legal baseline soil cadmium content established by the Spanish legislation seems not valid neither from the point of view of the effect on the crop growth nor from the point of view of the metal accumulation in the edible part of the plant. In order to realistically declare contaminated soils by heavy metals, soil quality standards should be proposed taking into account the soil properties. Further research in other agricultural areas of the region would improve the basis for proposing adequate soil quality standards for heavy metals as highlighted by the European Thematic Strategy for Soil Protection.

  9. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J

    2008-12-15

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials.

  10. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  11. Simulations of indirectly driven gas-filled capsules at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Weber, S. V.; Casey, D. T.; Eder, D. C.; Pino, J. E.; Smalyuk, V. A.; Remington, B. A.; Rowley, D. P.; Yeamans, C. B.; Tipton, R. E.; Barrios, M.; Benedetti, R.; Berzak Hopkins, L.; Bleuel, D. L.; Bond, E. J.; Bradley, D. K.; Caggiano, J. A.; Callahan, D. A.; Cerjan, C. J.; Clark, D. S.; Divol, L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Gas-filled capsules imploded with indirect drive on the National Ignition Facility have been employed as symmetry surrogates for cryogenic-layered ignition capsules and to explore interfacial mix. Plastic capsules containing deuterated layers and filled with tritium gas provide a direct measure of mix of ablator into the gas fuel. Other plastic capsules have employed DT or D{sup 3}He gas fill. We present the results of two-dimensional simulations of gas-filled capsule implosions with known degradation sources represented as in modeling of inertial confinement fusion ignition designs; these are time-dependent drive asymmetry, the capsule support tent, roughness at material interfaces, and prescribed gas-ablator interface mix. Unlike the case of cryogenic-layered implosions, many observables of gas-filled implosions are in reasonable agreement with predictions of these simulations. Yields of TT and DT neutrons as well as other x-ray and nuclear diagnostics are matched for CD-layered implosions. Yields of DT-filled capsules are over-predicted by factors of 1.4–2, while D{sup 3}He capsule yields are matched, as well as other metrics for both capsule types.

  12. Test-meal palatability is associated with overconsumption but better represents preceding changes in appetite in non-obese males.

    Science.gov (United States)

    Deighton, Kevin; Frampton, James; Gonzalez, Javier T

    2016-09-01

    Single-course, ad libitum meals are recommended for the assessment of energy intake within appetite research. This study represents the first investigation of the comparative sensitivity of two single-course, ad libitum meals designed to differ in palatability. We conducted two experiments using a preload study design. All protocols were identical except for the energy content of the preloads (Expt 1: 579 and 1776 kJ; Expt 2: 828 and 4188 kJ). During each experiment, ten healthy men completed four experimental trials constituting a low- or high-energy preload beverage, a 60-min intermeal interval and consumption of a pasta-based or a porridge-based, ad libitum meal. Appetite ratings were measured throughout each trial, and palatability was assessed after food consumption. Preload manipulation did not influence appetite (P=0·791) or energy intake (P=0·561) in Expt 1. Palatability and energy intake were higher for the pasta meal than for the porridge meal in both experiments (palatability P≤0·002; energy intake P≤0·001). In Expt 2, consumption of the high-energy preload decreased appetite (P=0·051) and energy intake (P=0·002). Energy compensation was not significantly different between pasta and porridge meals (P=0·172), but was more strongly correlated with preceding changes in appetite at the pasta meal (r -0·758; P=0·011) than the porridge meal (r -0·498; P=0·143). The provision of a highly palatable, pasta-based meal produced energy intakes that were more representative of preceding appetite ratings, but the moderately palatable, porridge-based meal produced more ecologically valid energy intakes. Ad libitum meal selection and design may require a compromise between sensitivity and ecological validity.

  13. One-repetition maximum strength test represents a valid means to assess leg strength in vivo in humans.

    Science.gov (United States)

    Verdijk, Lex B; van Loon, Luc; Meijer, Kenneth; Savelberg, Hans H C M

    2009-01-01

    Skeletal muscle strength is often determined to evaluate the adaptive response to an exercise intervention programme. Although dynamometry is considered the "gold standard" for the assessment of muscle strength in vivo, one-repetition maximum (1-RM) testing performed on training-specific equipment is more commonly applied. We assessed the validity of specific knee extension 1-RM testing by comparison with dynamometry in a heterogeneous population (n=55). All participants performed 1-RM tests on regular leg extension and leg press machines. Additionally, isometric (at seven different knee angles) and isokinetic (at four different velocities) knee extension peak torques were determined. Pearson's r was calculated for the relationship between 1-RM data and peak torques for the entire population and for subgroups defined by age and gender. One-repetition maximum strength correlated strongly with the dynamometer results. One-repetition maximum leg extension correlated more strongly with peak torques than did 1-RM leg press (0.78leg muscle strength in vivo in young and elderly men and women. Considering the importance of training specificity in strength assessment, we argue that 1-RM testing can be applied to assess changes in leg muscle strength following an exercise intervention.

  14. Venting of a Water/Inhibited Propylene Glycol Mixture in a Vacuum Environment-Characterization and Representative Test Results

    Science.gov (United States)

    Ungar, Eugene K.; Erickson, Lisa R.

    2011-01-01

    A planned use of the Orion space vehicle involves its residence at the International Space Station for six months at a time. One concept of operations involves temporarily venting portions of the idle Orion active thermal control system (ATCS) during the docked phase, preventing freezing. The venting would have to be reasonably complete with few, if any, completely filled pockets of frozen liquid. Even if pockets of frozen liquid did not damage the hardware during the freezing process, they could prevent the system from filling completely prior to its reactivation. The venting of single component systems in a space environment has been performed numerous times and is well understood. Local nucleation occurs at warm, relatively massive parts of the system, which creates vapor and forces the bulk liquid out of the system. The remnants of the liquid will freeze, then evaporate over time through local heating. Because the Orion ATCS working fluid is a 50/50 mixture of water and inhibited propylene glycol, its boiling behavior was expected to differ from that of a pure fluid. It was thought that the relatively high vapor pressure water might evaporate preferentially, leaving behind a mixture enriched with the low vapor pressure propylene glycol, which would be vaporization ]resistant. Owing to this concern, a test was developed to compare the evaporation behavior of pure water, a 50/50 mixture of water and inhibited propylene glycol, and inhibited propylene glycol. The test was performed using room temperature fluids in an instrumented thin walled stainless steel vertical tube. The 1 in x 0.035 in wall tube was instrumented with surface thermocouples and encased in closed cell polyurethane foam. Reticulated polyurethane foam was placed inside the tube to reduce the convection currents. A vacuum system connected to the top of the tube set the pressure boundary condition. Tests were run for the three fluids at back pressures ranging from 1 to 18 torr. During each test

  15. Indications of capsule endoscopy in Crohn´s disease.

    Science.gov (United States)

    Luján-Sanchis, Marisol; Sanchis-Artero, Laura; Suárez-Callol, Patricia; Medina-Chuliá, Enrique

    2014-01-01

    Capsule endoscopy currently plays a relevant role for Crohn´s disease. This manuscript will discuss the current indications and practical uses of capsule endoscopy in this disease. It is a non-invasive technique that represents a significant advance in the endoscopic diagnosis of small bowel conditions. These circumstances, together with its diagnostic yield and excellent tolerability, make it considerably acceptable by both patients and physicians. This paper discusses the current evidence on the specific circumstances where capsule endoscopy may be indicated for three specific scenarios: Suspected Crohn´s disease, indeterminate colitis, and established Crohn´s disease, where it plays an extensive role. Furthermore, the impact and implications of capsule endoscopy results for follow-up are reviewed. These recommendations must be interpreted and applied in the setting of the integral, individual management of these patients. Understanding its appropriate use in daily clinical practice and an analysis of results may define endoscopic scoring systems to assess activity and mucosal healing in this condition. The present role of capsule endoscopy for Crohn´s disease is subject to ongoing review, and appropriate usage uncovers novel applications likely to result in relevant changes for the future management of these patients.

  16. Fatigue Lives of Specimens Representing Critical Locations in Mirage III Spars under Australian and Swiss Test Spectra,

    Science.gov (United States)

    1985-02-01

    Library Qantas Airways Limited Ansett Airlines of Australia. Library BHP, Melbourne Research Laboratories Commonwealth Aircraft Corporation, Library Hawker...where the crack initiated. The results of a fractographic analysis of the spar fracture surface are contained in Reference 4, and the significance on the...in the failure regions under the two test spectra. An important implication of this analysis was that, unless this difference in lives could be

  17. Representing dispositions

    Directory of Open Access Journals (Sweden)

    Röhl Johannes

    2011-08-01

    Full Text Available Abstract Dispositions and tendencies feature significantly in the biomedical domain and therefore in representations of knowledge of that domain. They are not only important for specific applications like an infectious disease ontology, but also as part of a general strategy for modelling knowledge about molecular interactions. But the task of representing dispositions in some formal ontological systems is fraught with several problems, which are partly due to the fact that Description Logics can only deal well with binary relations. The paper will discuss some of the results of the philosophical debate about dispositions, in order to see whether the formal relations needed to represent dispositions can be broken down to binary relations. Finally, we will discuss problems arising from the possibility of the absence of realizations, of multi-track or multi-trigger dispositions and offer suggestions on how to deal with them.

  18. Brief Report: The KIDSCREEN Follow-Up Study on Health-Related Quality of Life (HRQoL) in Spanish Children and Adolescents. Pilot Test and Representativeness

    Science.gov (United States)

    Palacio-Vieira, J. A.; Villalonga-Olives, E.; Alonso, J.; Valderas, J. M.; Herdman, M.; Espallargues, M.; Berra, S.; Rajmil, L.

    2010-01-01

    The Spanish KIDSCREEN follow-up study reassessed the Spanish baseline sample (n = 840) of the European KIDSCREEN study 3 years later (2006). The aims of this paper were to describe the KIDSCREEN follow-up study and the pilot test, and to analyze participation rates and representativeness. Instruments included the KIDSCREEN-52 HRQoL measure and a…

  19. Capsule endoscopy of the esophagus.

    Science.gov (United States)

    Waterman, Matti; Gralnek, Ian M

    2009-08-01

    Video capsule endoscopy has acquired wide clinical acceptance since its the US Food and Drug Administration approval in 2001. Recently, the technology of video capsule endoscopy has been adapted to other organs in the gastrointestinal tract, including the esophagus and colon. In this review, we discuss esophageal capsule endoscopy (ECE)-the procedure, its indications, contraindications, safety, and future applications. ECE is a minimally invasive procedure that uses special video capsules with ability to acquire images from 2 cameras with high image storing speed of 14 to 18 frames per second. A special ingestion procedure allows for prolonged esophageal transit time and an optimized view of the gastroesophageal junction. ECE has been shown to have moderately high sensitivity and accuracy in the diagnosis and surveillance of Barrett esophagus in patients with gastroesophageal reflux disease but has not demonstrated superiority to esogastroduodenoscopy in cost-effectiveness models. In patients with portal hypertension, ECE has a sensitivity of 63% to 100% for screening of esophageal varices, but does not seem to be superior to esogastroduodenoscopy in its cost-effectiveness. No serious complications have been reported after ECE although a low rate of esophageal capsule retention (0.7% to 2.2%) has been reported, usually because of unsuspected esophageal strictures. Contraindications to capsule endoscopy include known or suspected gastrointestinal and esophageal obstruction, strictures, or fistulas, intestinal pseudoobstruction, and children under 10 years of age. It is expected that improvements in imaging technology will improve the accuracy of ECE with the development of immunological-based and chemical-based diagnostic capabilities.

  20. Suggestions from Representatives of the International Language Testing Association for Revision of the "AERA/APA/NCME Standards for Educational and Psychological Testing."

    Science.gov (United States)

    Stansfield, Charles W.; Spolsky, Bernard

    The International Language Testing Association has some 250 members in 15 countries. Most are specialists in the testing of second language skills, with a special interest in performance assessment because of the testing of speaking and writing performance that is critical to second language skills assessment. The association believes that certain…

  1. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  2. FY 2013 Summary Report: Post-Irradiation Examination of Zircaloy-4 Samples in Target Capsules and Initiation of Bending Fatigue Testing for Used Nuclear Fuel Vibration Integrity Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Howard, Richard H [ORNL; Yan, Yong [ORNL; Wang, Jy-An John [ORNL; Ott, Larry J [ORNL; Howard, Rob L [ORNL

    2013-10-01

    This report documents ongoing work performed at Oak Ridge National Laboratory (ORNL) for the Department of Energy, Office of Fuel Cycle Technology Used Fuel Disposition Campaign (UFDC), and satisfies the deliverable for milestone M2FT-13OR0805041, “Data Report on Hydrogen Doping and Irradiation in HFIR.” This work is conducted under WBS 1.02.08.05, Work Package FT-13OR080504 ST “Storage and Transportation-Experiments – ORNL.” The objectives of work packages that make up the S&T Experiments Control Account are to conduct the separate effects tests (SET) and small-scale tests that have been identified in the Used Nuclear Fuel Storage and Transportation Data Gap Prioritization (FCRD-USED-2012-000109). In FY 2013, the R&D focused on cladding and container issues and small-scale tests as identified in Sections A-2.9 and A-2.12 of the prioritization report.

  3. Analysis and design of a capsule landing system and surface vehicle control system for Mars exploration. [performance tests of remote control equipment for roving vehicles

    Science.gov (United States)

    Gisser, D. G.; Frederick, D. K.; Sandor, G. N.; Shen, C. N.; Yerazunis, S. W.

    1976-01-01

    Problems related to the design and control of an autonomous rover for the purpose of unmanned exploration of the planets were considered. Building on the basis of prior studies, a four wheeled rover of unusual mobility and maneuverability was further refined and tested under both laboratory and field conditions. A second major effort was made to develop autonomous guidance. Path selection systems capable of dealing with relatively formidable hazard and terrains involving various short range (1.0-3.0 meters), hazard detection systems using a triangulation detection concept were simulated and evaluated. The mechanical/electronic systems required to implement such a scheme were constructed and tested. These systems include: laser transmitter, photodetectors, the necessary data handling/controlling systems and a scanning mast. In addition, a telemetry system to interface the vehicle, the off-board computer and a remote control module for operator intervention were developed. Software for the autonomous control concept was written. All of the systems required for complete autonomous control were shown to be satisfactory except for that portion of the software relating to the handling of interrupt commands.

  4. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    Science.gov (United States)

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Design and manufacturing of 05F-01K instrumented capsule for nuclear fuel irradiation in Hanaro

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, J. M.; Shin, Y. T.; Park, S. J. (and others)

    2007-07-15

    An instrumented capsule was developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel pellet elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in Hanaro. The instrumented capsule(02F-11K) for measuring and monitoring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. It was successfully irradiated in the test hole OR5 of Hanaro from March 14, 2003 to June 1, 2003 (53.84 full power days at 24 MW). In the year of 2004, 3 test fuel rods and the instrumented capsule(03F-05K) were designed and manufactured to measure fuel centerline temperature, internal pressure of fuel rod, and fuel axial deformation during irradiation test. This capsule was irradiated in the test hole OR5 of Hanaro reactor from April 26, 2004 to October 1, 2004 (59.5 EFPD at 24 {approx} 30 MW). The six typed dual instrumented fuel rods, which allow for two characteristics to be measured simultaneously in one fuel rod, have been designed and manufactured to enhance the efficiency of the irradiation test using the instrumented fuel capsule. The 05F-01K instrumented fuel capsule was designed and manufactured for a design verification test of the three dual instrumented fuel rods. The irradiation test of the 05F-01K instrumented fuel capsule will be carried out at the OR5 vertical experimental hole of Hanaro.

  6. Representing Development

    DEFF Research Database (Denmark)

    Representing Development presents the different social representations that have formed the idea of development in Western thinking over the past three centuries. Offering an acute perspective on the current state of developmental science and providing constructive insights into future pathways...... and development, addressing their contemporary enactments and reflecting on future theoretical and empirical directions. The first section of the book provides an historical account of early representations of development that, having come from life science, has shaped the way in which developmental science has...... approached development. Section two focuses upon the contemporary issues of developmental psychology, neuroscience and developmental science at large. The final section offers a series of commentaries pointing to the questions opened by the previous chapters, looking to outline the future lines...

  7. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  8. Capsule endoscopy in pediatric patients

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Wireless capsule endoscope (WCE) for the investigation of the small bowel is an approved technique both in adults and children (more than 10 years old). The present review provides data on the indications, diagnostic yield, adverse events and limitations of the WCE technique in children and tries to predict the future of WCE usage in this population of patients.

  9. Quality evaluation of simvastatin compounded capsules

    Directory of Open Access Journals (Sweden)

    Flávia Dias Marques-Marinho

    2011-09-01

    Full Text Available Simvastatin is commercially available as tablets and compounded capsules in Brazil. Very few reports regarding these capsules' quality, and consequently their efficacy, are available. The pharmaceutical quality of 30 batches of 20 mg simvastatin capsules from the market was evaluated by weight determination, content uniformity, disintegration (Brazilian Pharmacopeia, assay and dissolution test (USP32 tablet monograph. A HPLC method was developed for assay, content uniformity and dissolution test, and specifications were also established. Out of the 30 batches evaluated, 29 showed capsule disintegration within 45 min and individual weight variation was within ±10% or ±7.5% relative to average weight, for 300 mg, respectively. Only 27 batches met dissolution test criteria with values >80% of the labeled amount in 45 min; 21 batches showed simvastatin content between 90.0-110.0% of the labeled amount and 19 batches had at least 9 out of 10 capsules with content uniformity values between 85.0-115.0% of the labeled amount with RSDNo Brasil, a sinvastatina está comercialmente disponível na forma de comprimidos e cápsulas manipuladas. Poucos relatos estão disponíveis sobre a qualidade e, consequentemente, a eficácia dessas cápsulas. A qualidade de 30 lotes de sinvastatina 20 mg cápsulas do mercado foi avaliada através da determinação de peso, uniformidade de conteúdo, desintegração (Farmacopéia Brasileira, doseamento e teste de dissolução (monografia comprimidos USP32. Método por CLAE foi desenvolvido para o doseamento, uniformidade de conteúdo e teste de dissolução; além disso, especificações foram estabelecidas. Dos 30 lotes avaliados, 29 apresentaram desintegração da cápsula até 45 min e a variação do peso individual foi ± 10% ou ± 7,5% em relação ao peso médio, se 300 mg, respectivamente. Apenas 27 lotes preencheram os critérios do teste de dissolução com valores > 80% da quantidade rotulada, em 45 min, 21

  10. RAMA Surveillance Capsule and Component Activation Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Kenneth E.; Jones, Eric N. [TransWare Enterprises Inc., 1565 Mediterranean Dr., Sycamore, IL 60178 (United States); Carter, Robert G. [Electric Power Research Institute, 1300 West W. T. Harris Blvd., Charlotte, NC 28262 (United States)

    2011-07-01

    This paper presents the calculated-to-measured ratios associated with the application of the RAMA Fluence Methodology software to light water reactor surveillance capsule and reactor component activation evaluations. Comparisons to measurements are performed for pressurized water reactor and boiling water reactor surveillance capsule activity specimens from seventeen operating light water reactors. Comparisons to measurements are also performed for samples removed from the core shroud, top guide, and jet pump brace pads from two reactors. In conclusion: The flexible geometry modeling capabilities provided by RAMA, combined with the detailed representation of operating reactor history and anisotropic scattering detail, produces accurate predictions of the fast neutron fluence and neutron activation for BWR and PWR surveillance capsule geometries. This allows best estimate RPV fluence to be determined without the need for multiplicative bias corrections. The three-dimensional modeling capability in RAMA provides an accurate estimate of the fast neutron fluence for regions far removed from the core mid-plane elevation. The comparisons to activation measurements for various core components indicate that the RAMA predictions are reasonable, and notably conservative (i.e., C/M ratios are consistently greater than unity). It should be noted that in the current evaluations, the top and bottom fuel regions are represented by six inch height nodes. As a result, the leakage-induced decrease in power near the upper and lower edges of the core are not well represented in the current models. More precise predictions of fluence for components that lie above and below the core boundaries could be obtained if the upper and lower fuel nodes were subdivided into multiple axial regions with assigned powers that reflect the neutron leakage at the top and bottom of the core. This use of additional axial sub-meshing at the top and bottom of the core is analogous to the use of pin

  11. Regional material properties of the human hip joint capsule ligaments.

    Science.gov (United States)

    Hewitt, J; Guilak, F; Glisson, R; Vail, T P

    2001-05-01

    The hip joint capsule functions to constrain translation between the femur and acetabulum while allowing rotational and planar movements. Despite the crucial role it plays in the pathogenesis of hip instability, little is known about its biomechanical properties. The goal of this study was to determine the regional material properties of the iliofemoral and ischiofemoral ligaments of the capsule. Ten human cadaveric specimens of each ligament were tested to failure in tension. The stress at failure, strain at failure, strain energy density at failure, toe- and linear-region elastic moduli, and the Poisson's ratio were measured for each ligament. The strain to failure was greatest in the ischiofemoral ligament, while no significant difference was noted in failure stress by region or ligament. The Young's moduli of elasticity ranged from 76.1 to 285.8 MPa among the different ligaments, and were generally consistent with properties previously reported for the shoulder capsule. The elastic moduli and strain energy density at failure differed by region. No significant differences in Poisson's ratio were found by region or ligament. The average Poisson's ratio was approximately 1.4, consistent with anisotropic behavior of ligamentous tissues. Understanding the material properties of the hip capsule may help the orthopaedic surgeon better understand normal ligament function, and thereby choose a surgical approach or strategy of repair. Furthermore, knowledge of the normal mechanical function of the hip capsule ligaments could assist in the evaluation of the success of a repair.

  12. Chemical inhibition of bacterial protein tyrosine phosphatase suppresses capsule production.

    Science.gov (United States)

    Standish, Alistair J; Salim, Angela A; Zhang, Hua; Capon, Robert J; Morona, Renato

    2012-01-01

    Capsule polysaccharide is a major virulence factor for a wide range of bacterial pathogens, including Streptococcus pneumoniae. The biosynthesis of Wzy-dependent capsules in both gram-negative and -positive bacteria is regulated by a system involving a protein tyrosine phosphatase (PTP) and a protein tyrosine kinase. However, how the system functions is still controversial. In Streptococcus pneumoniae, a major human pathogen, the system is present in all but 2 of the 93 serotypes found to date. In order to study this regulation further, we performed a screen to find inhibitors of the phosphatase, CpsB. This led to the observation that a recently discovered marine sponge metabolite, fascioquinol E, inhibited CpsB phosphatase activity both in vitro and in vivo at concentrations that did not affect the growth of the bacteria. This inhibition resulted in decreased capsule synthesis in D39 and Type 1 S. pneumoniae. Furthermore, concentrations of Fascioquinol E that inhibited capsule also lead to increased attachment of pneumococci to a macrophage cell line, suggesting that this compound would inhibit the virulence of the pathogen. Interestingly, this compound also inhibited the phosphatase activity of the structurally unrelated gram-negative PTP, Wzb, which belongs to separate family of protein tyrosine phosphatases. Furthermore, incubation with Klebsiella pneumoniae, which contains a homologous phosphatase, resulted in decreased capsule synthesis. Taken together, these data provide evidence that PTPs are critical for Wzy-dependent capsule production across a spectrum of bacteria, and as such represents a valuable new molecular target for the development of anti-virulence antibacterials.

  13. Chemical inhibition of bacterial protein tyrosine phosphatase suppresses capsule production.

    Directory of Open Access Journals (Sweden)

    Alistair J Standish

    Full Text Available Capsule polysaccharide is a major virulence factor for a wide range of bacterial pathogens, including Streptococcus pneumoniae. The biosynthesis of Wzy-dependent capsules in both gram-negative and -positive bacteria is regulated by a system involving a protein tyrosine phosphatase (PTP and a protein tyrosine kinase. However, how the system functions is still controversial. In Streptococcus pneumoniae, a major human pathogen, the system is present in all but 2 of the 93 serotypes found to date. In order to study this regulation further, we performed a screen to find inhibitors of the phosphatase, CpsB. This led to the observation that a recently discovered marine sponge metabolite, fascioquinol E, inhibited CpsB phosphatase activity both in vitro and in vivo at concentrations that did not affect the growth of the bacteria. This inhibition resulted in decreased capsule synthesis in D39 and Type 1 S. pneumoniae. Furthermore, concentrations of Fascioquinol E that inhibited capsule also lead to increased attachment of pneumococci to a macrophage cell line, suggesting that this compound would inhibit the virulence of the pathogen. Interestingly, this compound also inhibited the phosphatase activity of the structurally unrelated gram-negative PTP, Wzb, which belongs to separate family of protein tyrosine phosphatases. Furthermore, incubation with Klebsiella pneumoniae, which contains a homologous phosphatase, resulted in decreased capsule synthesis. Taken together, these data provide evidence that PTPs are critical for Wzy-dependent capsule production across a spectrum of bacteria, and as such represents a valuable new molecular target for the development of anti-virulence antibacterials.

  14. Evaluation of the location of capsules swallowed with food during the pharyngeal phase triggering in asymptomatic adults.

    Science.gov (United States)

    Uchimura, Érica Mayumi Takase; Barcelos, Irene Harumi Kamata; Paiva, Deborah Brandão de; Mourão, Lucia Figueiredo; Crespo, Agricio Nubiato

    2014-01-01

    To assess the location of hard gelatin capsules in the pharyngeal phase triggering among asymptomatic adults. The location of the bolus during the pharyngeal phase triggering provides information about the sensorimotor model of the beginning of deglutition onset. To evaluate the location of hard gelatin capsules in the pharyngeal phase triggering among asymptomatic adults. A videofluoroscopy swallowing study was carried out in 60 subjects (14 male and 46 female participants) aged between 27 and 55 years, who were evaluated with hard gelatin capsules #00 and #3 containing barium sulfate, swallowed with liquid food and pudding, in free volume. The first laryngeal elevation movement was the criterion to locate the pharyngeal phase triggering. Statistical analysis was based on the McNemar test. Capsule #3 presented higher percentage of location in the tongue dorsum compared to capsule #00, and capsule #00 presented higher percentage of location in the tongue base and vallecula compared to capsule #3. There was a difference between different capsules swallowed with liquid (p=0.016) and pudding (p=0.037). The capsule size influenced the location of the pharyngeal phase triggering. Smaller capsules started pharyngeal phase in the most anterior region (tongue dorsum) compared to larger capsules.

  15. Development of capsule design support subprograms for 3-dimensional temperature calculation using FEM Code NISA

    Energy Technology Data Exchange (ETDEWEB)

    Tobita, Masahiro; Matsui, Yoshinori [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2003-03-01

    Prediction of irradiation temperature is one of the important issues in the design of the capsule for irradiation test. Many kinds of capsules with complex structure have been designed for recent irradiation requests, and three-dimensional (3D) temperature calculation becomes inevitable for the evaluation of irradiation temperature. For such 3D calculation, however, many works are usually needed for input data preparation, and a lot of time and resources are necessary for parametric studies in the design. To improve such situation, JAERI introduced 3D-FEM (finite element method) code NISA (Numerically Integrated elements for System Analysis) and developed several subprograms, which enabled to support input preparation works in the capsule design. The 3D temperature calculation of the capsule are able to carried out in much easier way by the help of the subprograms, and specific features in the irradiation tests such as non-uniform gamma heating in the capsule, becomes to be considered. (author)

  16. Regenerated cellulose capsules for controlled drug delivery: Part IV. In-vitro evaluation of novel self-pore forming regenerated cellulose capsules.

    Science.gov (United States)

    Bhatt, Bhavik; Kumar, Vijay

    2017-01-15

    In the present work, the release mechanisms of active pharmaceutical ingredients (APIs) enclosed in self-pore forming regenerated cellulose (RC) two-piece hard shell capsules are described. The RC capsules were fabricated using a modified dip-coating approach, which yielded an assembled dosage form that was equivalent in size and shape to a conventional gelatin two-piece hard shell capsule. Drug release characteristics from RC capsules were evaluated using potassium chloride, diphenhydramine hydrochloride, tramadol hydrochloride, niacinamide, acetaminophen and ketoprofen as model APIs. The RC capsules act as a barrier coated reservoir device that releases the enclosed API at a zero order release rate. When comparing all the API's release behavior from RC capsules, a power-law relationship was observed between their zero-order release rates and their respective aqueous solubilities. Osmotic as well as diffusive mechanisms are involved in the release of the enclosed API. The osmotic mechanism's contribution to zero order release rate increases as the aqueous solubility of the tested APIs inside the capsule increases. The osmotic mediated flux and the apparent diffusivity of the APIs through the capsule wall is a competitive process and the osmotic mediated flux of the enclosed API begins to override its diffusivity through the capsule wall as the API solubility increases. This behavior is attributed to the wide range of pore sizes observed in RC membranes, from our prior analysis. The fluid permeability analysis shows that the RC capsules presented in this work may be better suited for osmotic drug delivery applications than conventional encapsulated systems described in the literature. Copyright © 2016. Published by Elsevier B.V.

  17. Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M. H.; Choo, K. N.; Cho, M. S.; Park, S. J.; Kang, Y. H.; Son, J. M.; Shin, Y. T.; Lee, D. S.; Kim, B. G

    2005-07-15

    The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The receptacle of a single channel test loop was slightly modified in March 2005, and the out-pile test to evaluate the structural integrity of the creep capsule(03S-07K) and the material capsule(04M-17U) was performed by using a single channel and a half core test loop. From the pressure drop test of the dummy fuel, we confirmed that the modified single channel test loop has an equal flow rate to the HANARO. In the case of the material capsule with the bottom structure of a solid cone shape, the optimized diameter of the bottom structure which satisfies HANARO's flow requirement(19.6 kg/s) is 71mm. The maximum peak displacement of the two capsules measured at the half core test loop is lower than 1.0mm. From the analysis results, we can confirm that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072mm. The fundamental frequency of the capsule under water is 9.64Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71mm in diameter will be applicable to the material and special capsules in the future.

  18. Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water

    Energy Technology Data Exchange (ETDEWEB)

    Nussinovitch, A., E-mail: amos.nussi@mail.huji.ac.il; Dagan, O.

    2015-12-15

    Highlights: • Novel liquid-core capsules with a non-crosslinked alginate core were produced. • Capsules demonstrated highest efficiency adsorption of ∼300 mg Pb{sup 2+}/g alginate. • Regeneration was carried out by suspending capsules in 1 M HNO{sub 3} for 24 h. • Adsorption capacities of the capsules followed the order: Pb{sup 2+} > Cu{sup 2+} > Cd{sup 2+} > Ni{sup 2+}. - Abstract: Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan–alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb{sup 2+}/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb{sup +2}/g dry alginate vs. 267 mg Pb{sup +2}/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules’ ability to adsorb other heavy-metal cations – copper (Cu{sup 2+}), cadmium (Cd{sup 2+}) and nickel (Ni{sup 2+}) – was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation’s affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1 M nitric acid suspension for 24 h. Capsules could undergo three regeneration cycles before becoming damaged.

  19. The Cryptococcus neoformans capsule: lessons from the use of optical tweezers and other biophysical tools.

    Directory of Open Access Journals (Sweden)

    Bruno ePontes

    2015-06-01

    Full Text Available The fungal pathogen Cryptococcus neoformans causes life-threatening infections in immunocompromised individuals, representing one of the leading causes of morbidity and mortality in AIDS patients. The main virulence factor of C. neoformans is the polysaccharide capsule; however, many fundamental aspects of capsule structure and function remain poorly understood. Recently, important capsule properties were uncovered using optical tweezers and other biophysical techniques, including dynamic and static light scattering, zeta potential and viscosity analyses. This review provides an overview of the latest findings in this emerging field, explaining the impact of these findings on our understanding of C. neoformans biology and resistance to host immune defenses.

  20. The Cryptococcus neoformans capsule: lessons from the use of optical tweezers and other biophysical tools.

    Science.gov (United States)

    Pontes, Bruno; Frases, Susana

    2015-01-01

    The fungal pathogen Cryptococcus neoformans causes life-threatening infections in immunocompromised individuals, representing one of the leading causes of morbidity and mortality in AIDS patients. The main virulence factor of C. neoformans is the polysaccharide capsule; however, many fundamental aspects of capsule structure and function remain poorly understood. Recently, important capsule properties were uncovered using optical tweezers and other biophysical techniques, including dynamic and static light scattering, zeta potential and viscosity analysis. This review provides an overview of the latest findings in this emerging field, explaining the impact of these findings on our understanding of C. neoformans biology and resistance to host immune defenses.

  1. Isotretinoin Oil-Based Capsule Formulation Optimization

    Directory of Open Access Journals (Sweden)

    Pi-Ju Tsai

    2013-01-01

    Full Text Available The purpose of this study was to develop and optimize an isotretinoin oil-based capsule with specific dissolution pattern. A three-factor-constrained mixture design was used to prepare the systemic model formulations. The independent factors were the components of oil-based capsule including beeswax (X1, hydrogenated coconut oil (X2, and soybean oil (X3. The drug release percentages at 10, 30, 60, and 90 min were selected as responses. The effect of formulation factors including that on responses was inspected by using response surface methodology (RSM. Multiple-response optimization was performed to search for the appropriate formulation with specific release pattern. It was found that the interaction effect of these formulation factors (X1X2, X1X3, and X2X3 showed more potential influence than that of the main factors (X1, X2, and X3. An optimal predicted formulation with Y10 min, Y30 min, Y60 min, and Y90 min release values of 12.3%, 36.7%, 73.6%, and 92.7% at X1, X2, and X3 of 5.75, 15.37, and 78.88, respectively, was developed. The new formulation was prepared and performed by the dissolution test. The similarity factor f2 was 54.8, indicating that the dissolution pattern of the new optimized formulation showed equivalence to the predicted profile.

  2. Design modification and stress analysis of bottom structure for the instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M. H.; Kang, Y. H.; Joo, K. N.; Oh, J. M.; Joe, M. S.; Ryu, J. S.; Jeo, Y. G. [KAERI, Taejon (Korea, Republic of)

    2003-10-01

    The bottom structure of the instrumented capsule, which is used for the irradiation test in the HANARO incore, plays an important role to support the capsule main structure within the hexagonal flow tube. This paper is described the design modification and stress analysis results to obtain the structural integrity of bottom structure for the instrumented capsule. The capsule's bottom guide structure consisted of three guide pins before, but it is modified as one block structure to obtain an efficient flow of coolant water and a stabilized shape structurally. The structural integrity of the bottom structure is estimated by the stress calculation of components such as welding parts, bolts and neck parts of the rod tip due to the force applied by handling tool. The tensile and shear stresses are calculated by using a mechanical formulas, and a finite element model development is planned to be performed for more complex assembly of the capsule bottom structure.

  3. Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water.

    Science.gov (United States)

    Nussinovitch, A; Dagan, O

    2015-12-15

    Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan-alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb(2+)/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb(+2)/g dry alginate vs. 267 mg Pb(+2)/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules' ability to adsorb other heavy-metal cations - copper (Cu(2+)), cadmium (Cd(2+)) and nickel (Ni(2+)) - was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation's affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1M nitric acid suspension for 24h. Capsules could undergo three regeneration cycles before becoming damaged.

  4. Status of DOE/JAERI collaborative program phase II and phase III capsules

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, J.P.; Lenox, K.E. [Oak Ridge National Lab., TN (United States); Ioka, I.; Wakai, E.

    1997-04-01

    Significant progress has been made during the last year in the post-irradiation examinations (PIE) of the specimens from nine DOE ORNL/JAERI collaborative capsules and in the design and fabrication of four additional capsules. JP21, JP22, CTR-62, and CTR-63 were disassembled, JP20 tensile specimens were tested, and a variety of specimens from the RB-60J-1, 330J-1, and 400J-1 capsules were tested. Fabrication of RB-11J and 12J was completed and progress made in the matrix finalization and design of RB-10J and JP25.

  5. Video capsule endoscopy in the emergency department: a prospective study of acute upper gastrointestinal hemorrhage.

    Science.gov (United States)

    Meltzer, Andrew C; Ali, M Aamir; Kresiberg, Roderick B; Patel, Gayatri; Smith, Jeff P; Pines, Jesse M; Fleischer, David E

    2013-04-01

    Video capsule endoscopy has been used to diagnose gastrointestinal hemorrhage and other small bowel diseases but has not been tested in an emergency department (ED) setting. The objectives in this pilot study are to demonstrate the ability of emergency physicians to detect blood in the upper gastrointestinal tract with capsule endoscopy after a short training period, measure ED patient acceptance of capsule endoscopy, and estimate the test characteristics of capsule endoscopy to detect acute upper gastrointestinal hemorrhage. During a 6-month period at a single academic hospital, eligible patients underwent video capsule endoscopy (Pillcam Eso2; Given Imaging) in the ED. Video images were reviewed by 4 blinded physicians (2 emergency physicians with brief training in capsule endoscopy interpretation and 2 gastroenterologists with capsule endoscopy experience). A total of 25 subjects with acute upper gastrointestinal hemorrhage were enrolled. There was excellent agreement between gastroenterologists and emergency physicians for the presence of fresh or coffee-ground blood (0.96 overall agreement; κ=0.90). Capsule endoscopy was well tolerated by 96% of patients and showed an 88% sensitivity (95% confidence interval 65% to 100%) and 64% specificity (95% confidence interval 35% to 92%) for the detection of fresh blood. Capsule endoscopy missed 1 bleeding lesion located in the postpyloric region, which was not imaged because of expired battery life. Video capsule endoscopy is a sensitive way to identify upper gastrointestinal hemorrhage in the ED. It is well tolerated and there is excellent agreement in interpretation between gastroenterologists and emergency physicians. Copyright © 2012. Published by Mosby, Inc.

  6. Thermal analysis of an irradiation capsule for high-temperature materials to be used in future nuclear systems

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Choo, Kee Nam; Kim, Sung Ryul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of). Dept. of Neutron Application Technology

    2016-05-15

    The requirement of irradiation of materials at high temperature are gradually increasing with the development of Gen-IV (Generation-IV) reactors, which will be operated at high temperatures and under a high neutron flux. To overcome the restrictions for the high temperature use of Al thermal media of the existing standard capsule, a new capsule was designed and fabricated. Through the irradiation test, the structural integrity and safety of the capsule during irradiation at high temperature were confirmed.

  7. The test-retest reliability of the latent construct of executive function depends on whether tasks are represented as formative or reflective indicators.

    Science.gov (United States)

    Willoughby, Michael T; Kuhn, Laura J; Blair, Clancy B; Samek, Anya; List, John A

    2017-10-01

    This study investigates the test-retest reliability of a battery of executive function (EF) tasks with a specific interest in testing whether the method that is used to create a battery-wide score would result in differences in the apparent test-retest reliability of children's performance. A total of 188 4-year-olds completed a battery of computerized EF tasks twice across a period of approximately two weeks. Two different approaches were used to create a score that indexed children's overall performance on the battery-i.e., (1) the mean score of all completed tasks and (2) a factor score estimate which used confirmatory factor analysis (CFA). Pearson and intra-class correlations were used to investigate the test-retest reliability of individual EF tasks, as well as an overall battery score. Consistent with previous studies, the test-retest reliability of individual tasks was modest (rs ≈ .60). The test-retest reliability of the overall battery scores differed depending on the scoring approach (rmean = .72; rfactor_score = .99). It is concluded that the children's performance on individual EF tasks exhibit modest levels of test-retest reliability. This underscores the importance of administering multiple tasks and aggregating performance across these tasks in order to improve precision of measurement. However, the specific strategy that is used has a large impact on the apparent test-retest reliability of the overall score. These results replicate our earlier findings and provide additional cautionary evidence against the routine use of factor analytic approaches for representing individual performance across a battery of EF tasks.

  8. Capsule implosions driven by dynamic hohlraum x-rays

    Science.gov (United States)

    Bailey, James

    2005-10-01

    Dynamic hohlraum experiments at the Z facility already implode capsules with up to 80 kJ absorbed x-ray energy. However, many challenging issues remain for ICF. The present experiments use diagnostic capsules to address two of these issues: symmetry measurement and control and building understanding of the capsule/hohlraum implosion system. A suite of x-ray spectrometers record time and space resolved spectra emitted by Ar tracer atoms in the implosion core, simultaneously from up to three different quasi-orthogonal directions. Comparing the results with simulation predictions provide severe tests of understanding. These data also can used to produce a tomographic reconstruction of the time resolved core temperature and density profiles. X-ray and neutron diagnostics are used to examine how the implosion conditions change as the capsule design changes. The capsule design changes include variations in CH wall thickness and diameter, Ge-doped CH shells, and SiO2 shells. In addition, a new campaign investigating Be capsule implosions is beginning. Be capsules may offer superior performance for dynamic hohlraum research and it may be possible to investigate NIF-relevant Be implosion issues such as the fill tube effects, sensitivity to columnar growth associated with sputtered Be capsule fabrication, and the effect of Cu dopants on implosion conditions. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the U.S. Dept. of Energy under contract No. DE-AC04-94AL85000. * In collaboration with G.A. Rochau, G.A. Chandler, S.A. Slutz, P.W. Lake, G. Cooper, G.S. Dunham, R.J. Leeper, R. Lemke, T.A. Mehlhorn, T.J. Nash, D.S. Nielsen, K. Peterson, C.L. Ruiz, D.B. Sinars, J. Torres, W. Varnum, Sandia; R.C. Mancini, T.J. Buris-Mog, UNR; I. Golovkin, J.J. MacFarlane, PRISM; A. Nikro, D. Steinman, J.D. Kilkenny, H. Xu, General Atomics; M. Bump, T.C. Moore, K-tech; D.G. Schroen, Schafer

  9. Poly(N-isopropylacrylamide)/poly(dopamine) capsules.

    Science.gov (United States)

    Zhang, Yan; Teo, Boon M; Goldie, Kenneth N; Städler, Brigitte

    2014-05-20

    Polymer capsules are an interesting concept considered in nanobiotechnology. Approaches that facilitate their assembly remain sought after. Poly(dopamine) (PDA) has been considered and successfully applied in this context. We recently demonstrated that PDA could be copolymerized with different types of poly(N-isopropylacrylamide) (pNiPAAm) to assemble mixed films on planar substrates. Herein, we transferred this approach onto colloidal substrates and characterized the film thickness depending on the film composition and template particles size. While the membrane of capsules assembled using 5 μm template particles exhibited strong dependency on the film composition, smaller templates led to capsules with similar membrane thickness. We then compared the permeability of different capsules using fluorescently labeled dextran and fluorescein. We found that the permeability of capsules was heavily dependent on the polymer composition and the template particle size. These fundamental findings contribute to the potential of these capsules, assembled in one-step, for biomedical applications.

  10. Status of DOE/JAERI collaborative program phase II and phase III capsules

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, J.E.; Lenox, K.E. [Oak Ridge National Lab., TN (United States); Ioka, I.

    1996-04-01

    During this reporting period, the HFIR-MFE-RB-200J-1 spectrally tailored capsules were disassembled and the individual specimens recovered, sorted, and identified. Tensile testing and irradiation creep measurements will be performed during the next reporting period.

  11. Disassembly of irradiated lithium-bonded capsules containing vanadium alloy specimens

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H.; Strain, R.V.

    1996-04-01

    Capsules containing vanadium alloy specimens from irradiation experiments in FFTF and EBR-II are being processed to remove the lithium bond and retrieve the specimens for testing. The work has progressed smoothly.

  12. Fabrication of the Supplemental Surveillance Capsules to Construct the Data of High-dose Irradiation Embrittlement

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Ki; Maeng, Young Jae; Kim, Kyung Sik; Lim, Mi Joung; Yoo, Choon Sung; Kim, Byoung Chul [Korea Reactor Integrity Surveillance Technology, Daejeon (Korea, Republic of)

    2015-10-15

    In order to monitor the neutron irradiation embrittlement of the reactor vessel material, the surveillance program should be implemented during the reactor operation through the plant life. This surveillance program requires the surveillance capsules which contain the various test specimens, thermal monitors, and neutron dosimeters. For PWRs in Korea, total six surveillance capsules are installed before plant operation and are programmed to be withdrawn and tested periodically in accordance with the surveillance program. The surveillance capsules are typically installed in the downcomer region and are located closer to the reactor core than the vessel wall in order to get more accelerated embrittlement characteristics of the vessel material. The supplemental surveillance capsules were fabricated to obtain the data of high-dose irradiation embrittlement. All test specimens in the capsules were made with the archive material of Hanbit Units 3 and 4. The supplemental capsules were designed to have the same outside dimensions as the capsules of Hanbit Unit 1 and were installed in Hanbit Unit 1. The withdrawal schedule will be calculated.

  13. The Lidose hard capsule formulation of fenofibrate is suprabioavailable compared to the nanoparticle tablet formulation under high-fat fed conditions.

    Science.gov (United States)

    Verbeeck, Roger K; De Niet, Sophie; Lebrun, Sonia; Tremege, Mickael; Rennie, Tim W; Coffiner, Monte; Streel, Bruno; Cahay, Bernard

    2015-01-01

    The therapeutic equivalence of multiple registered fenofibrate formulations, several of which are suprabioavailable and therefore marketed at lower dosage strengths than their reference products, is based on the results of bioequivalence studies. Most of these formulations show a higher bioavailability when taken with a high-fat meal. The relative bioavailability of two of these formulations, the 200 mg Lidose hard capsules and the 145 mg nanoparticle tablets, was assessed when taken with a high-fat meal. In this single dose, 2-way, randomized, crossover study, 24 healthy subjects received a 200 mg fenofibrate Lidose hard capsule (Test) and a 145 mg nanoparticle tablet (Reference) under high-fat fed conditions. Plasma concentrations of fenofibric acid were measured up to 72 hours by using a validated LC-MS/MS method. The geometric mean ratios (Test/Reference) and the 90% confidence intervals for AUC0-t and Cmax were 1.37 (131.58 - 142.88) and 1.38 (124.60 - 152.93), respectively. The median (range) Tmax- values of fenofibric acid were 4.5 h (3.0 - 8.0 h) and 3.25 h (1.0 - 6.5 h) after administration of the Lidose hard capsule and the nanoparticle tablet, respectively. Under high-fat fed conditions the extent of fenofibrate absorption was 37% higher for the 200 mg Lidose hard capsule compared to the 145 mg nanoparticle tablet, which is exactly as expected based on a mg-to-mg weight basis. The results of the present study underline the importance of assessing bioequivalence of fenofibrate formulations under identical fed conditions, and preferentially after a high-fat meal as this condition represents the worst-case scenario. Furthermore, the results of this study demonstrate that the 145 mg nanoparticle tablet is not bioequivalent to the 200 mg Lidose hard capsule when administered under high-fat meal conditions.

  14. Colon Capsule Endoscopy: Review and Perspectives

    Directory of Open Access Journals (Sweden)

    David Friedel

    2016-01-01

    Full Text Available Colon capsule endoscopy utilizing PillCam COLON 2 capsule allows for visualization potentially of the entire colon and is currently approved for patients who cannot withstand the rigors of traditional optical colonoscopy (OC and associated sedation as well as those that had an OC that was incomplete for technical reasons other than a poor preparation. We will then describe the prior experience and current status of colon capsule endoscopy.

  15. The Design and Safety Review for a Creep Capsule With Four Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Seo, C. G.; Choi, M. H.; Choo, K. N.; Sohn, J. M.; Kang, Y. H.; Kim, B. G. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    To review the safety in the irradiation test of a creep capsule with 4 specimens, the design analysis for the incore creep test in the normal and abnormal operation condition was performed. In the normal operation condition, the reactivity effect was estimated and the analysis on the stress and temperature was performed. In the abnormal operation condition, the effect exerted on the capsule body by a leakage or breakage of the stress loading unit was analyzed.

  16. A representative-sandwich model for simultaneously coupled mechanical-electrical-thermal simulation of a lithium-ion cell under quasi-static indentation tests

    Science.gov (United States)

    Zhang, Chao; Santhanagopalan, Shriram; Sprague, Michael A.; Pesaran, Ahmad A.

    2015-12-01

    The safety behavior of lithium-ion batteries under external mechanical crush is a critical concern, especially during large-scale deployment. We previously presented a sequentially coupled mechanical-electrical-thermal modeling approach for studying mechanical-abuse-induced short circuit. In this work, we study different mechanical test conditions and examine the interaction between mechanical failure and electrical-thermal responses, by developing a simultaneously coupled mechanical-electrical-thermal model. The present work utilizes a single representative-sandwich (RS) to model the full pouch cell with explicit representations for each individual component such as the active material, current collector, separator, etc. Anisotropic constitutive material models are presented to describe the mechanical properties of active materials and separator. The model predicts accurately the force-strain response and fracture of battery structure, simulates the local failure of separator layer, and captures the onset of short circuit for lithium-ion battery cells under sphere indentation tests with three different diameters. Electrical-thermal responses to the three different indentation tests are elaborated and discussed. Numerical studies are presented to show the potential impact of test conditions on the electrical-thermal behavior of the cell after the occurrence of short circuit.

  17. Single human sperm cryopreservation method using hollow-core agarose capsules.

    Science.gov (United States)

    Araki, Yasuyuki; Yao, Tatsuma; Asayama, Yuta; Matsuhisa, Akio; Araki, Yasuhisa

    2015-10-01

    To develop an efficient cryopreservation method using a single sperm. Experimental study. Laboratory of a private institute. A fertile donor. We produced hollow-core capsules with agarose walls. A single human sperm was injected into each capsule as per the conventional intracytoplasmic sperm injection (ICSI) method. The capsules that contained the spermatozoa were cryopreserved on polycarbonate or nylon mesh sheets using nitrogen vapor. Before their use, the capsules were thawed and recovered. The motile spermatozoa in the capsules were counted. The recovery rates of the agarose capsules and the spermatozoa in these capsules after thawing and the mortality and survival rates of the spermatozoa. The recovery rates of the capsules were 91.5% (75/82) using polycarbonate sheets (PS) and 98.3% (59/60) using mesh sheets (MS) after thawing. The recovered capsules were not at all damaged. The recovery rates of the spermatozoa were 91.5% (75/82) using PS and 96.7% (58/60) using MS. Sperm motility rates were 85.3% (64/75) and 82.8% (48/58), whereas the survival rates of the immotile spermatozoa by the hypoosmotic swelling test were 81.8% (9/11) and 50.0% (5/10); furthermore, the total survival rates of the spermatozoa were 97.3% (73/75) and 91.4% (53/58) using PS and MS, respectively. There was no significant difference between the results obtained using PS and MS. A cryopreservation method for a single sperm using an agarose capsule has been developed. The method is expected to be useful in ICSI treatment in patients with few spermatozoa. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Critical swelling of fluctuating capsules

    Science.gov (United States)

    Diamant, Haim; Haleva, Emir

    2009-03-01

    In many natural transport processes the solute molecules to be transported are encapsulated in semipermeable, flexible membrane vesicles of micron size. We study the swelling of such fluctuating capsules, as the number of encapsulated particles is increased, or the concentration of the outer solution is decreased. The approach to the maximum volume-to-area ratio and the associated buildup of membrane tension involve a continuous phase transition and follow universal scaling laws. The criticality and its features are model-independent, arising solely from the interplay between volume and surface degrees of freedom.ootnotetextE. Haleva and H. Diamant, Phys. Rev. Lett. 101, 078104 (2008).

  19. The Paternal Landscape along the Bight of Benin – Testing Regional Representativeness of West-African Population Samples Using Y-Chromosomal Markers

    Science.gov (United States)

    Larmuseau, Maarten H. D.; Vessi, Andrea; Jobling, Mark A.; Van Geystelen, Anneleen; Primativo, Giuseppina; Biondi, Gianfranco; Martínez-Labarga, Cristina; Ottoni, Claudio; Decorte, Ronny; Rickards, Olga

    2015-01-01

    and powerful geographical information carried by the Y-chromosome makes it an important locus to test the representativeness of a certain sample even in the genomic era, especially in poorly investigated areas like Africa. PMID:26544036

  20. The Paternal Landscape along the Bight of Benin - Testing Regional Representativeness of West-African Population Samples Using Y-Chromosomal Markers.

    Directory of Open Access Journals (Sweden)

    Maarten H D Larmuseau

    . Therefore, the uniquely and powerful geographical information carried by the Y-chromosome makes it an important locus to test the representativeness of a certain sample even in the genomic era, especially in poorly investigated areas like Africa.

  1. Clinical utility, safety and tolerability of capsule endoscopy in urban Southeast Asian population

    Institute of Scientific and Technical Information of China (English)

    Tiing-Leong Ang; Kwong-Ming Fock; Tay-Meng Ng; Eng-Kiong Teo; Yi-Lyn Tan

    2003-01-01

    AIM:Capsule endoscopy has demonstrated its clinical utility in the evaluation of small bowel pathology in several Western studies. In this prospective study, we aimed to determine the clinical utility, safety and tolerability of capsule endoscopy in the evaluation of suspected small bowel disease in an urban Southeast Asian population.METHODS: We used the given (M2A) capsule endoscopy system in 16 consecutive patients with suspected small bowel pathology. In 9 patients the indication was obscure gastrointestinal bleeding, while in 6 patients it was to determine the extent of small bowel involvement in Crohn's disease. One patient underwent capsule endoscopy for evaluation of chronic abdominal pain. Patient's tolerability to the procedure was evaluated by standardized questionnaires and all patients were reviewed at one week to ensure that the capsule had been excreted without any adverse events.RESULTS: Abnormal findings were present in 8 patients (50%). The cause of obscure gastrointestinal bleeding was determined in 5 out of 9 patients. Findings included 2 cases of angiodysplasia, 2 cases of jejunal ulcers and 1 case of both angiodysplasia and jejunal ulcer. One patient had small bowel erosions and foci of erythema of doubtful significance.Ileal lesions were diagnosed in 2 out of 6 patients with Crohn's disease. Capsule endoscopy was well tolerated by all patients. One patient with Crohn's disease had a complication of capsule retention due to terminal ileum stricture. The capsule eventually passed out spontaneously after 1 month.CONCLUSION: Our study, which represented the first Asian series, further confirms the diagnostic utility, safety and tolerability of wireless capsule endoscopy.

  2. How helpful is capsule endoscopy to surgeons?

    Institute of Scientific and Technical Information of China (English)

    Osman Ersoy; Bulent Sivri; Yusuf Bayraktar

    2007-01-01

    Capsule endoscopy is a new technology that, for the first time, allows complete, non-invasive endoscopic imaging of the small bowel. The efficacy of capsule endoscopy in the diagnosis of suspected small bowel diseases has been established. Important applications for surgeons include observations of obscure gastrointestinal bleeding and small bowel neoplasms.

  3. The future of wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.

  4. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    chorionic gonadotropin. Oocytes were collected by ultrasonically guided transvaginal aspiration, and spermatozoa were prepared by swim-up technique. The gametes were placed in agar capsules 4 hr after oocyte collection, and the capsules were introduced to the uterine fundus using an insertion tube...

  5. Unreported complication of Bravo pH capsule dislodged intothe pyriform sinus

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    We report an unexpected, previously unreported complicationof Bravo pH capsule dislodgement. During BravopH testing of a 44-year-old man with gastroesophagealreflux disease, we were unable to endoscopicallyvisualize the capsule attached to the esophageal wallafter deployment. After multiple attempts to detect thecapsule, it was visualized in the left pyriform sinus. Asthere was significant risk for pulmonary dislodgement,ENT and pulmonary physicians were immediatelyconsulted to review options for safe removal. Ultimately,ENT successfully retrieved the capsule with a foreignbody removal forceps. The Bravo pH test is generallya well-tolerated diagnostic tool used to confirm thepresence of abnormal esophageal acid reflux. While fewcomplications have been reported, technical difficultiescan occur, including poor data reception, misplacement,and early dislodgement. Rarely, more serious complicationscan occur, ranging from esophageal wall traumato capsule aspiration. Gastroenterologists performingthis procedure should be aware of the low, but nontrivial,risk of complications.

  6. Hydrolytic Activity of Esterase-Antibody Complexes Retained Within Gel Capsules After Complex Isolation.

    Science.gov (United States)

    Shimazaki, Youji; Miyatsuka, Rino

    2017-01-09

    Delipidation in biological samples is important for some diagnostic tests and protein analyses. Lipids in the samples can be hydrolyzed by native esterases (ESs) within gel capsules after ES, and ES-antibody complexes are specifically trapped, extracted, and separated. Acrylamide and agarose gel capsules containing complexes of ES antibody were produced after the complexes were extracted using protein A-immobilized membranes, separated by non-denaturing electrophoresis, and stained by colloidal silver using glucose as a reductant. ES activity of ES-antibody complexes within the gel capsule was significantly higher than that in the complexes with the control antibodies upon isolation, separation, and detection of the complex. In addition, lipids bound to human serum albumin decreased after human plasma was treated with gel capsules containing ES-antibody complexes. We demonstrate that the gel capsule containing ES-antibody complexes can be successfully isolated using techniques described in this study. Furthermore, delipidation of human plasma is obtained by incubation with the gel capsule. These results indicate that surplus materials such as lipids in biological samples can be removed or reduced by gel capsule containing enzymes.

  7. WESF cesium capsule behavior at high temperature or during thermal cycling

    Energy Technology Data Exchange (ETDEWEB)

    Tingey, G.L.; Gray, W.J.; Shippell, R.J.; Katayama, Y.B.

    1985-06-01

    Double-walled stainless steel (SS) capsules prepared for storage of radioactive /sup 137/Cs from defense waste are now being considered for use as sources for commercial irradiation. Cesium was recovered at B-plant from the high-level radioactive waste generated during processing of defense nuclear fuel. It was then purified, converted to the chloride form, and encapsulated at the Hanford Waste Encapsulation and Storage Facility (WESF). The molten cesium chloride salt was encapsulated by pouring it into the inner of two concentric SS cylinders. Each cylinder was fitted with a SS end cap that was welded in place by inert gas-tungsten arc welding. The capsule configuration and dimensions are shown in Figure 1. In a recent review of the safety of these capsules, Tingey, Wheelwright, and Lytle (1984) indicated that experimental studies were continuing to produce long-term corrosion data, to reaffirm capsule integrity during a 90-min fire where capsule temperatures reached 800/sup 0/C, to monitor mechanical properties as a function of time, and to assess the effects of thermal cycling due to periodic transfer of the capsules from a water storage pool to the air environment of an irradiator facility. This report covers results from tests that simulated the effects of the 90-min fire and from thermal cycling actual WESF cesium capsules for 3845 cycles over a period of six months. 11 refs., 39 figs., 9 tabs.

  8. Availability and price of malaria rapid diagnostic tests in the public and private health sectors in 2011: results from 10 nationally representative cross-sectional retail surveys.

    Science.gov (United States)

    Poyer, Stephen; Shewchuk, Tanya; Tougher, Sarah; Ye, Yazoume; Mann, Andrea G; Willey, Barbara A; Thomson, Rebecca; Amuasi, John H; Ren, Ruilin; Wamukoya, Marilyn; Taylor, Mark; Nguah, Samuel Blay; Mberu, Blessing; Kalolella, Admirabilis; Juma, Elizabeth; Festo, Charles; Johanes, Boniface; Diap, Graciela; Bruxvoort, Katia; Ansong, Daniel; Hanson, Kara; Arnold, Fred; Goodman, Catherine

    2015-06-01

    To describe the state of the public and private malaria diagnostics market shortly after WHO updated its guidelines for testing all suspected malaria cases prior to treatment. Ten nationally representative cross-sectional cluster surveys were conducted in 2011 among public and private health facilities, community health workers and retail outlets (pharmacies and drug shops) in nine countries (Tanzania mainland and Zanzibar surveyed separately). Eligible outlets had antimalarials in stock on the day of interview or had stocked antimalarials in the past 3 months. Three thousand four hundred and thirty-nine rapid diagnostic test (RDT) products from 39 manufacturers were audited among 12,197 outlets interviewed. Availability was typically highest in public health facilities, although availability in these facilities varied greatly across countries, from 15% in Nigeria to >90% in Madagascar and Cambodia. Private for-profit sector availability was 46% in Cambodia, 20% in Zambia, but low in other countries. Median retail prices for RDTs in the private for-profit sector ranged from $0.00 in Madagascar to $3.13 in Zambia. The reported number of RDTs used in the 7 days before the survey in public health facilities ranged from 3 (Benin) to 50 (Zambia). Eighteen months after WHO updated its case management guidelines, RDT availability remained poor in the private sector in sub-Saharan Africa. Given the ongoing importance of the private sector as a source of fever treatment, the goal of universal diagnosis will not be achievable under current circumstances. These results constitute national baselines against which progress in scaling-up diagnostic tests can be assessed. © 2015 John Wiley & Sons Ltd.

  9. The Type a and Type b Polysaccharide Capsules Predominate in an International Collection of Invasive Kingella kingae Isolates.

    Science.gov (United States)

    Porsch, Eric A; Starr, Kimberly F; Yagupsky, Pablo; St Geme, Joseph W

    2017-01-01

    Kingella kingae is an encapsulated Gram-negative bacterium and an important etiology of osteoarticular infections in young children. A recent study examining a diverse collection of carrier and invasive K. kingae isolates from Israel revealed four distinct polysaccharide capsule types. In this study, to obtain a global view of K. kingae capsule type diversity, we examined an international collection of isolates using a multiplex PCR approach. The collection contained all four previously identified capsule types and no new capsule types. Over 95% of invasive isolates in the collection were type a or type b, similar to the findings in Israel. These results suggest that the type a and type b polysaccharide capsules may have enhanced pathogenic properties or may mark clonal groups of strains with specific virulence genes. In addition, they raise the possibility that a vaccine containing the type a and type b capsules might be an effective approach to preventing K. kingae disease. IMPORTANCEKingella kingae has emerged as a significant cause of septic arthritis, osteomyelitis, and bacteremia in young children. A recent study examining a diverse collection of K. kingae isolates from Israel revealed four different polysaccharide capsule types in this species, designated types a to d. To determine the global distribution of K. kingae capsule types, we assembled and capsule typed an international collection of K. kingae isolates. The findings reported here show that the type a and type b capsules represent >95% of the invasive isolates, similar to the Israeli isolate collection, suggesting that a polysaccharide-based vaccine targeting these two capsules could be an attractive approach to prevent K. kingae disease.

  10. The association of Matrix Gla protein isomers with calcification in capsules surrounding silicone breast implants

    OpenAIRE

    Larry W. Hunter; Lieske, John C.; Tran, Nho V.; Miller, Virginia M.

    2011-01-01

    Implanted silicone medical prostheses induce a dynamic sequence of histologic events in adjacent tissue resulting in the formation of a fibrotic peri-prosthetic capsule. In some cases, capsular calcification occurs, requiring surgical intervention. In this study we investigated capsules from silicone gel-filled breast prostheses to test the hypothesis that this calcification might be regulated by the small vitamin K-dependent protein, matrix Gla protein (MGP), a potent inhibitor of arterial c...

  11. Elastic constants of the human lens capsule.

    Science.gov (United States)

    Fisher, R F

    1969-03-01

    1. A technique is described whereby the elasticity of the human lens capsule has been determined at birth and throughout life. This technique requires three separate determinations: (a) thickness; (b) stress and strain; (c) Poisson's ratio; (a) the capsule was clamped between accurately perforated ground glass plates and its thickness determined by noting the change in depth of focus between Latex spherules adhering to its upper and lower surfaces; (b) the undisturbed capsule was then placed in a specially designed glass distension apparatus and the relationship between volume and pressure recorded when it was distended with isotonic saline. The permeability of the capsule was also measured; (c) in some cases Poisson's ratio was determined by measuring the change of thickness of the capsule and the height to which it rose when distended with isotonic saline at different pressures. An apparatus was designed for this purpose.2. The average thickness of the anterior capsule increases from birth until about the 60th year but thereafter it decreases slightly.3. Poisson's ratio was about 0.47 for both cat and human capsule, and no significant variations with age in human capsule could be detected.4. Corrected volume pressure curves obeyed Hook's law almost to the point of capsule rupture.5. In childhood Young's Modulus of elasticity is about 6 x 10(7) dyn/cm(2) and decreases to 3 x 10(7) dyn/cm(2) at 60 and 1.5 x 10(7) dyn/cm(2) in extreme old age.6. The ultimate tensile stress was 2.3 x 10(7) dyn/cm(2) in young capsules and 0.7 x 10(7) dyn/cm(2) in old ones. The maximum percentage elongation was 29 per cent and independent of age.7. The implications of these findings are discussed in relation to(a) the mechanical properties of the lens capsule;(b) the ageing of the lens capsule and basement membranes; and(c) the decrease in elasticity of the lens capsule as a cause of presbyopia.

  12. Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.

    Science.gov (United States)

    Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho

    2015-03-01

    Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.

  13. 消化道生理参数检测胶囊系统的研究进展%Research progress of capsule system for alimentary tract physiological parameters testing in the alimentary tract

    Institute of Scientific and Technical Information of China (English)

    刘洪英; 李晓华; 皮喜田; 贾子如

    2011-01-01

    胃肠道内的生理参数是评价胃肠道动力性疾病的重要参数.传统的插管方法会给病人带来严重的不适感,且会影响到病人的正常生活.为了克服传统插管方法的缺点,出现了一种新型的监测生理参数的胶囊系统,它可以根据生理参数的差异来诊断胃肠道疾病.针对生理参数检测胶囊系统对国际研究成果和国内研究现状进行了综述.%The physiological parameters within the alimentary tract is an important parameter which is used to diagnose alimentary motility disorders. Conventional catheter-based monitoring systems are uncomfortable and interfere with the normal activity of the patient. To overcome these disadvantages, a new type of capsule containing sensor for physiological parameters monitoring is presented, which is based on differences in physiological parameters to diagnose alimentary tract disease. International research achievement and domestic research at present of the capsule system for physiological parameters monitoring is presented.

  14. 正交试验法优化白金胶囊中合欢花提取工艺%Optimization of Extraction Process for Albizia julibrissin in Baijin Capsule by Orthogonal Test

    Institute of Scientific and Technical Information of China (English)

    张慧; 张晋; 祁娟娟; 党晓芳; 曹飒丽; 倪健

    2014-01-01

    目的:优化筛选白金胶囊中合欢花的提取工艺。方法以合欢花中槲皮苷及总黄酮的提取率作为评价指标,采用正交设计法考察溶剂用量、提取时间、提取次数对提取结果的影响,确定最佳提取工艺。结果合欢花的最佳提取工艺为:采用12倍量70%乙醇,回流提取2次,每次2 h。结论该提取工艺简便易行、稳定可靠,可为白金胶囊的实际生产提供依据。%Objective To optimize the extraction process of Albizia julibrissin in Baijin Capsule. Methods Using the extraction rate of quercitrin and total flavonoids as indexes, the orthogonal design was used to investigate effects of solvent volume, extraction time and extraction frequency on extraction results. Results The optimal extracting condition was as follows:extracted 2 times with 12 fold 70%alcohol, 2 h for each time. Conclusion The optimized process condition was simple, stable and feasible. It provides the basis for the production of Baijin Capsule.

  15. Testing the Paradigm that Ultra-Luminous X-ray Sources as a Class Represent Accreting Intermediate-Mass Black Holes

    CERN Document Server

    Berghea, C T; Colbert, E J M; Roberts, T P

    2008-01-01

    To test the idea that ultraluminous X-ray sources (ULXs) in external galaxies represent a class of accreting Intermediate-Mass Black Holes (IMBHs), we have undertaken a program to identify ULXs and a lower luminosity X-ray comparison sample with the highest quality data in the {\\it Chandra} archive. We establish a general property of ULXs that the most X-ray luminous objects possess the flattest X-ray spectra (in the {\\it Chandra} band pass). No prior sample studies have established the general hardening of ULX spectra with luminosity. This hardening occurs at the highest luminosities (absorbed luminosity $\\geq5\\times10^{39}$ erg s$^{-1}$) and is in line with recent models arguing that ULXs are actually stellar-mass black holes. From spectral modeling, we show that the evidence originally taken to mean that ULXs are IMBHs - i.e., the ``simple IMBH model'' - is nowhere near as compelling when a large sample of ULXs is looked at properly. During the last couple of years, {\\it XMM-Newton} spectroscopy of ULXs ha...

  16. Tag gas capsule with magnetic piercing device

    Science.gov (United States)

    Nelson, Ira V.

    1976-06-22

    An apparatus for introducing a tag (i.e., identifying) gas into a tubular nuclear fuel element. A sealed capsule containing the tag gas is placed in the plenum in the fuel tube between the fuel and the end cap. A ferromagnetic punch having a penetrating point is slidably mounted in the plenum. By external electro-magnets, the punch may be caused to penetrate a thin rupturable end wall of the capsule and release the tag gas into the fuel element. Preferably the punch is slidably mounted within the capsule, which is in turn loaded as a sealed unit into the fuel element.

  17. Video capsule endoscopy and the hidden gastrointestinal diseases

    Directory of Open Access Journals (Sweden)

    Helmy Ahmed

    2006-01-01

    Full Text Available Video capsule endoscopy (VCE has recently been introduced to fill the gap between examinations of the upper and lower gastrointestinal tract, mainly to examine the small bowel (SB for sources of obscure bleeding in addition to many other indications. VCE represents a minute endoscope, embedded in a swallowable capsule that is propelled by peristalsis and achieves the journey to the right colon in 5-8 hours. Images captured by the capsule are recorded on a hard drive attached to the patient′s belt. Many studies have recently shown that the diagnostic yield of VCE is superior to that of push enteroscopy. This mini-review contains information on the technical aspects, indications, safety and tolerance of VCE. It is well known that radiological investigations of the small bowel (SB have a limited diagnostic yield, are relatively invasive, and often lead to late discovery of diseases, especially malignancy and profuse bleeding, at a worse stage. Also, push enteroscopy is limited by the depth of the insertion of the instrument to the proximal jejunum and, in the retrograde, to the last 50-80 cm of the terminal ileum, with an ability to visualize the entire SB only in 10-70% of cases. Introduction of video capsule endoscopy (VCE is therefore regarded a significant advance in investigating intestinal diseases, and closes the gap in evaluating the SB, "the black box" of endoscopy(1. This mini-review describes the current indications of VCE and the prerequisites for accurate examination, and briefly discusses its tolerance and safety.

  18. Biocompatible multilayer capsules engineered with a graphene oxide derivative: synthesis, characterization and cellular uptake

    Science.gov (United States)

    Del Mercato, Loretta L.; Guerra, Flora; Lazzari, Gianpiero; Nobile, Concetta; Bucci, Cecilia; Rinaldi, Rosaria

    2016-03-01

    Graphene-based capsules have strong potential for a number of applications, including drug/gene delivery, tissue engineering, sensors, catalysis and reactors. The ability to integrate graphene into carrier systems with three-dimensional (3D) geometry may open new perspectives both for fundamental tests of graphene mechanics and for novel (bio)technological applications. However, the assembly of 3D complexes from graphene or its derivatives is challenging because of its poor stability under biological conditions. In this work, we attempted to integrate a layer of graphene oxide derivative into the shell of biodegradable capsules by exploiting a facile layer-by-layer (LbL) protocol. As a first step we optimized the LbL protocol to obtain colloidal suspensions of isolated capsules embedding the graphene oxide derivative. As a following step, we investigated in detail the morphological properties of the hybrid capsules, and how the graphene oxide derivative layer influences the porosity and the robustness of the multilayer composite shells. Finally, we verified the uptake of the capsules modified with the GO derivative by two cell lines and studied their intracellular localization and biocompatibility. As compared to pristine capsules, the graphene-modified capsules possess reduced porosity, reduced shell thickness and a higher stability against osmotic pressure. They show remarkable biocompatibility towards the tested cells and long-term colloidal stability and dispersion. By combining the excellent mechanical properties of a graphene oxide derivative with the high versatility of the LbL method, robust and flexible biocompatible polymeric capsules with novel characteristics have been fabricated.Graphene-based capsules have strong potential for a number of applications, including drug/gene delivery, tissue engineering, sensors, catalysis and reactors. The ability to integrate graphene into carrier systems with three-dimensional (3D) geometry may open new perspectives

  19. Compounding of slow-release niacinamide capsules: feasibility and characterization.

    Science.gov (United States)

    Radojkovic, Branko; Milić, Jela; Calija, Bojan

    2012-01-01

    The purpose of this study was to assess the feasibility of extemporaneous compounding of slow-release oral dosage form of niacinamide and to evaluate its release kinetics. The model formulation (preparation) was developed in the form of powder-filled hard gelatin capsules. Two slow-release preparations with different ratios of hypromellose have been prepared and evaluated in comparison with an immediate-release preparation. The dissolution tests were performed as per United States Pharmacopoeia requirements: Type I Apparatus, over 7 hours. Both slow-release preparations, containing 40% and 60% v/v hypromellose, respectively, have showed slow release kinetics. The dissolution profiles were significantly different, with similarity factor f2niacinamide capsules can be successfully compounded using hypromellose as a sole release rate modifier, and that the release mechanism is comparable to hydrophilic polymer matrix-based systems.

  20. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b Section 520.1660b Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule...

  1. 21 CFR 520.1803 - Piperazine citrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Piperazine citrate capsules. 520.1803 Section 520... capsules. (a) Specifications. Piperazine citrate capsules contain piperazine citrate equivalent to 140 milligrams of piperazine base in each capsule. (b) Sponsor. See No. 021091 in § 510.600(c) of this chapter...

  2. 21 CFR 520.446 - Clindamycin capsules and tablets.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Clindamycin capsules and tablets. 520.446 Section... capsules and tablets. (a) Specifications—(1) Each capsule contains the equivalent of 25, 75, 150, or 300... 150 mg clindamycin as the hydrochloride salt. (3) Each capsule contains the equivalent of 25, 75, or...

  3. 21 CFR 520.390b - Chloramphenicol capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Chloramphenicol capsules. 520.390b Section 520... capsules. (a) Specifications. Each capsule contains 50, 100, 250, or 500 milligrams (mg) chloramphenicol... section. (1) Nos. 000069 and 050057 for capsules containing 50, 100, 250, or 500 mg chloramphenicol. (2...

  4. 21 CFR 520.2605 - Trimeprazine tartrate and prednisolone capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Trimeprazine tartrate and prednisolone capsules... Trimeprazine tartrate and prednisolone capsules. (a) Specifications. Each capsule contains 3.75 milligrams of trimeprazine in sustained released form (as the tartrate) and 1 milligram of prednisolone (capsule no. 1) or 7...

  5. 21 CFR 520.2345a - Tetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Tetracycline hydrochloride capsules. 520.2345a... Tetracycline hydrochloride capsules. (a) Specifications. Each capsule contains 50, 100, 125, 250, or 500... as in paragraph (c) of this section: (1) No. 000009: 250 mg per capsule. (2) No. 000069: 125, 250, or...

  6. Biocompatible multilayer capsules engineered with a graphene oxide derivative: synthesis, characterization and cellular uptake.

    Science.gov (United States)

    del Mercato, Loretta L; Guerra, Flora; Lazzari, Gianpiero; Nobile, Concetta; Bucci, Cecilia; Rinaldi, Rosaria

    2016-04-14

    Graphene-based capsules have strong potential for a number of applications, including drug/gene delivery, tissue engineering, sensors, catalysis and reactors. The ability to integrate graphene into carrier systems with three-dimensional (3D) geometry may open new perspectives both for fundamental tests of graphene mechanics and for novel (bio)technological applications. However, the assembly of 3D complexes from graphene or its derivatives is challenging because of its poor stability under biological conditions. In this work, we attempted to integrate a layer of graphene oxide derivative into the shell of biodegradable capsules by exploiting a facile layer-by-layer (LbL) protocol. As a first step we optimized the LbL protocol to obtain colloidal suspensions of isolated capsules embedding the graphene oxide derivative. As a following step, we investigated in detail the morphological properties of the hybrid capsules, and how the graphene oxide derivative layer influences the porosity and the robustness of the multilayer composite shells. Finally, we verified the uptake of the capsules modified with the GO derivative by two cell lines and studied their intracellular localization and biocompatibility. As compared to pristine capsules, the graphene-modified capsules possess reduced porosity, reduced shell thickness and a higher stability against osmotic pressure. They show remarkable biocompatibility towards the tested cells and long-term colloidal stability and dispersion. By combining the excellent mechanical properties of a graphene oxide derivative with the high versatility of the LbL method, robust and flexible biocompatible polymeric capsules with novel characteristics have been fabricated.

  7. Magnetic control system targeted for capsule endoscopic operations in the stomach--design, fabrication, and in vitro and ex vivo evaluations.

    Science.gov (United States)

    Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung

    2012-07-01

    This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.

  8. Study of split-ring resonators for use on a pharmaceutical drug capsule for microwave activated drug release

    DEFF Research Database (Denmark)

    Jónasson, Sævar Þór; Jensen, Brian Sveistrup; Johansen, Tom Keinicke

    2012-01-01

    In this paper, a novel method for externally activating a pharmaceutical drug capsule by use of split-ring resonators (SRR) is introduced. To this end, the effect of the orientation of the SRRs on the ability to activate the capsules is examined. A coplanar waveguide is used to excite an identical...... pair of SRRs fabricated on a substrate, representing an enlarged lid for a pharmaceutical drug capsule. Orientations where the electric field component of a quasi-TEM wave lies across the gap of the SRRs provides the largest response. The optimal case is when the electric field component lies across...

  9. Capsule Endoscopy: New Technology, Old Complication ...

    African Journals Online (AJOL)

    Capsule Endoscopy: New Technology, Old Complication. ... A 65-year-old female with a long standing history of anemia and obscure gastrointestinal ... The patient was resuscitated and taken up for an explorative laparotomy where a short ...

  10. Therapeutic Capsule Endoscopy: Opportunities and Challenges

    Directory of Open Access Journals (Sweden)

    Mahdi Rasouli

    2011-01-01

    Full Text Available The increasing demand for non-invasive (or less-invasive monitoring and treatment of medical conditions has attracted both physicians and engineers to work together and investigate new methodologies. Wireless capsule endoscopy is a successful example of such techniques which has become an accepted routine for diagnostic inspection of the gastrointestinal tract. This method offers a non-invasive alternative to traditional endoscopy and provides the opportunity for exploring distal areas of the small intestine which are otherwise not accessible. Despite these advantages, wireless capsule endoscopy is still limited in functionality compared to traditional endoscopy. Wireless capsule endoscopes with advanced functionalities, such as biopsy or drug delivery, are highly desirable. In this article, the current status of wireless capsule endoscopy is reviewed together with some of its possible therapeutic applications as well as the existing challenges.

  11. Test Vehicle Forebody Wake Effects on CPAS Parachutes

    Science.gov (United States)

    Ray, Eric S.

    2017-01-01

    Parachute drag performance has been reconstructed for a large number of Capsule Parachute Assembly System (CPAS) flight tests. This allows for determining forebody wake effects indirectly through statistical means. When data are available in a "clean" wake, such as behind a slender test vehicle, the relative degradation in performance for other test vehicles can be computed as a Pressure Recovery Fraction (PRF). All four CPAS parachute types were evaluated: Forward Bay Cover Parachutes (FBCPs), Drogues, Pilots, and Mains. Many tests used the missile-shaped Parachute Compartment Drop Test Vehicle (PCDTV) to obtain data at high airspeeds. Other tests used the Orion "boilerplate" Parachute Test Vehicle (PTV) to evaluate parachute performance in a representative heatshield wake. Drag data from both vehicles are normalized to a "capsule" forebody equivalent for Orion simulations. A separate database of PCDTV-specific performance is maintained to accurately predict flight tests. Data are shared among analogous parachutes whenever possible to maximize statistical significance.

  12. Measurement of capsule heat transfer gaps using neutron radiography

    Science.gov (United States)

    Thaler, L. A.

    1974-01-01

    A technique is described for measuring heat transfer gaps from neutron radiographs. The method involves scanning the radiograph negative with a recording microdensitometer to obtain a trace of the optical density variation across the diameter of the capsule. The optical density change representing the gap is measured from the microdensitometer trace and related to the physical measurement. Heat transfer gaps from 0.061 to 0.178 cm have been determined by this technique and agree with preassembly physical measurements to plus or minus 0.005 cm.

  13. Identifying Risk Factors for Recent HIV Infection in Kenya Using a Recent Infection Testing Algorithm: Results from a Nationally Representative Population-Based Survey.

    Directory of Open Access Journals (Sweden)

    Andrea A Kim

    Full Text Available A recent infection testing algorithm (RITA that can distinguish recent from long-standing HIV infection can be applied to nationally representative population-based surveys to characterize and identify risk factors for recent infection in a country.We applied a RITA using the Limiting Antigen Avidity Enzyme Immunoassay (LAg on stored HIV-positive samples from the 2007 Kenya AIDS Indicator Survey. The case definition for recent infection included testing recent on LAg and having no evidence of antiretroviral therapy use. Multivariate analysis was conducted to determine factors associated with recent and long-standing infection compared to HIV-uninfected persons. All estimates were weighted to adjust for sampling probability and nonresponse.Of 1,025 HIV-antibody-positive specimens, 64 (6.2% met the case definition for recent infection and 961 (93.8% met the case definition for long-standing infection. Compared to HIV-uninfected individuals, factors associated with higher adjusted odds of recent infection were living in Nairobi (adjusted odds ratio [AOR] 11.37; confidence interval [CI] 2.64-48.87 and Nyanza (AOR 4.55; CI 1.39-14.89 provinces compared to Western province; being widowed (AOR 8.04; CI 1.42-45.50 or currently married (AOR 6.42; CI 1.55-26.58 compared to being never married; having had ≥ 2 sexual partners in the last year (AOR 2.86; CI 1.51-5.41; not using a condom at last sex in the past year (AOR 1.61; CI 1.34-1.93; reporting a sexually transmitted infection (STI diagnosis or symptoms of STI in the past year (AOR 1.97; CI 1.05-8.37; and being aged <30 years with: 1 HSV-2 infection (AOR 8.84; CI 2.62-29.85, 2 male genital ulcer disease (AOR 8.70; CI 2.36-32.08, or 3 lack of male circumcision (AOR 17.83; CI 2.19-144.90. Compared to HIV-uninfected persons, factors associated with higher adjusted odds of long-standing infection included living in Coast (AOR 1.55; CI 1.04-2.32 and Nyanza (AOR 2.33; CI 1.67-3.25 provinces compared to

  14. Systematic Design of edical Capsule Robots

    OpenAIRE

    Beccani, M; Tunc, H; Taddese, AZ; Susilo, E; Volgiesi, P; Ledeczi, A; Valdastri, P

    2015-01-01

    Medical capsule robots that navigate inside the body as diagnostic and interventional tools are an emerging and challenging research area within medical CPSs. These robots must provide locomotion, sensing, actuation, and communication within severe size, power, and computational constraints. This paper presents the first effort for an open architecture, platform design, software infrastructure, and a supporting modular design environment for medical capsule robots to further this research area.

  15. Dynamics of nonspherical compound capsules in simple shear flow

    Science.gov (United States)

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-10-01

    The dynamics of an initially ellipsoidal compound capsule in a simple shear flow is investigated numerically using a three-dimensional front-tracking finite-difference model. Membrane bending resistance is included based on Helfrich's energy function besides the resistances against shear deformation and area dilatation governed by the constitutive law of Skalak et al. In this paper, we focus specifically on how the presence of a spherical inner capsule and its size affects the characteristics and transition of various dynamical states of nonspherical compound capsules (i.e., the outer capsule). Significant differences in the dynamical characteristics are observed between compound capsules and homogeneous capsules in both qualitative and quantitative terms. We find the transition from swinging to tumbling can occur at vanishing viscosity mismatch through increasing the inner capsule size alone to a critical value regardless of the initial shape of the nonspherical compound capsule (i.e., prolate or oblate). Besides, for compound capsules with viscosity mismatch, the critical viscosity ratio for the swinging-to-tumbling transition remarkably decreases by increasing the inner capsule size. It is thus concluded that the inner capsule size is a key governing parameter of compound capsule dynamics apart from the capillary number, aspect ratio, and viscosity ratio that have been long identified for homogeneous capsules. Further, we discuss the mechanisms underlying the effects of the inner capsule on the compound capsule dynamics from the viewpoint of the effective viscosity of internal fluid and find that the effects of the inner capsule on compound capsule dynamics are qualitatively similar to that of increasing the internal viscosity on homogeneous capsule dynamics. However, in quantitative terms, the compound capsule cannot be viewed as a homogeneous capsule with higher viscosity as obvious inhomogeneity in fluid stress distribution is induced by the inner membrane.

  16. [Bioequivalence research of cyclosporin soft capsules].

    Science.gov (United States)

    Wu, Yue; Mao, Mian; Wang, Ling; Jiang, Xuehua

    2012-04-01

    This paper is aimed to study the bioavailability and bioequivalence of Cyclosporin Soft Capsules (test preparation and reference preparation) in Chinese healthy volunteers. A high performance liquid chromatography-ultraviolet (HPLC-UV) method for determining the concentration of Cyclosporin A in human whole blood was developed and methodological validated. In accordance with the randomized two-period self crossover study, 24 volunteers received a single oral dose of 400 mg of test preparation or reference preparation. Multiple blood samples were collected post dose and then the concentration of Cyclosporin A in human whole blood samples was determined using the validated assay. The pharmacokinetic parameters including AUC0-t, Cmax, Tmax, and T1/2 were calculated using the non-compartmental method. The bioequivalence of the two preparations was evaluated. After receiving single dose of 400 mg of Cyclosporine A, the pharmacokinetic parameters of T1/2, Cmax, Tmax, and AUC0-t, of Cyclosporin A were (10.114 +/- 6.329) h and (9.717 +/- 4.076) h, (2021.235 +/- 298.581) ng x ml(-1) and (1992.192 +/- 1286.923) ng x ml(-1) (1.729 +/- 0.361) h and (1.813 +/- 0.323) h, (9824.811 +/- 1633.026) ng x h x ml(-1) and (10316.514 +/- 1395.955) ng x h x ml(-1) for test preparation and reference preparation, respectively. The statistical results suggested that these parameters were comparable between the two preparations. The results showed that the test preparation was bioequivalent with the reference preparation in healthy volunteers.

  17. Prostate specific antigen testing is associated with men's psychological and physical health and their healthcare utilisation in a nationally representative sample: a cross-sectional study

    National Research Council Canada - National Science Library

    Flahavan, Evelyn M; Drummond, Frances J; Bennett, Kathleen; Barron, Thomas I; Sharp, Linda

    2014-01-01

    ...) testing in primary care. The objective of this study was to investigate associations between PSA testing and the psychological and physical health, and healthcare utilisation of men in a population where PSA testing is widespread...

  18. 23rd August 2011 - Turkish Representatives of the Union of Chambers and Commodity Exchanges, E. Uluatam and S. Kologlu, visiting the LHC superconducting magnet test hall with Engineering Department Head R. Saban.

    CERN Multimedia

    Benoit Jeannet

    2011-01-01

    23rd August 2011 - Turkish Representatives of the Union of Chambers and Commodity Exchanges, E. Uluatam and S. Kologlu, visiting the LHC superconducting magnet test hall with Engineering Department Head R. Saban.

  19. Modeling of NIF Wetted-Foam Capsule Experiments

    Science.gov (United States)

    Peterson, Robert; Olson, Richard; Kline, John

    2015-11-01

    Wetting of a foam with liquid DT or DD in an ICF capsule provides a mechanism of directly controlling the convergence ratio of the implosion. The density of the DD or DT vapor in the central void in the CH foam is set by the temperature of the liquid fuel, so the convergence ratio is easily adjustable. The capsule is driven by a two step laser pulse on NIF. The ablator is made of high density carbon in these experiments, but it could be beryllium. The experiments will test how well the modeling computer codes agree with experiment as the convergence ratio increases. It is possible that has the convergence ratio increases, a point will be reached were the modeling no longer agree with experiment. We wish to find this limit. In the presentation we will present computer model simulations in 1-D of the performance of NIF wetted-foam capsules, where the vapor density, the ablator type, and the choice of fuel (DD or DT) are varied.

  20. An Innovative Wireless Endoscopic Capsule With Spherical Shape.

    Science.gov (United States)

    Fontana, Rossella; Mulana, Francesca; Cavallotti, Carmen; Tortora, Giuseppe; Vigliar, Mario; Vatteroni, Monica; Menciassi, Arianna

    2017-02-01

    This paper aims to contribute to the advancement of the Wireless Capsule Endoscopy (WCE) field for ColoRectal Cancer (CRC) screening, by developing all electronic circuits to build an innovative wireless endoscopic capsule with a spherical shape, conceived to reduce the friction during its locomotion and thus improving patient's acceptability. The proposed capsule embeds an image sensor with optics and Light Emitting Diodes (LEDs), a control unit with a telemetry module, an actuation system, a battery with a smart recharging circuit able to recharge in 20 minutes, a smart power-on circuit and a localization module. Everything is devised to fit in a small spherical shape with a diameter of 26 mm and a weight of 12.70 g. The authors present a description of the sub-modules involved in the capsule development, together with the firmware and hardware integration. In order to reduce the bandwidth for matching the specifications of the target commercial telemetry, the firmware interfacing of a custom encoder was performed, which is able to compress the incoming images with a negligible loss of information and occupying a number of Look Up-Tables (LUTs) less than 1780. As a preliminary work, a versatile Field Programmable Gate Arrays (FPGA) based demo-board system has been developed in order to test and optimize the functionalities and the performance of the single sub-modules and wireless vision chain system. This work allows to demonstrate the feasibility of a complex biomedical system, with severe constraints by highlighting the necessity to enhance the frame rate in the future.

  1. Controlled delivery of carvedilol nanosuspension from osmotic pump capsule: in vitro and in vivo evaluation.

    Science.gov (United States)

    Liu, Dandan; Yu, Shihui; Zhu, Zhihong; Lyu, Chunyang; Bai, Chunping; Ge, Huiqi; Yang, Xinggang; Pan, Weisan

    2014-11-20

    This study intended to develop a novel controlled delivery osmotic pump capsule of carvedilol nanosuspension. The capsule is assembled using a semi-permeable capsule shell with contents including nanosuspension drying powder, mannitol and Plasdone S-630. The physical characteristics of semi-permeable capsule walls were compared among different coating solutions under different temperature. The composition of the coating solution and drying temperature appeared to be important for the formation of the shells. Carvedilol nanosuspension was prepared by precipitation-ultrasonication technique and was further lyophilized. Response surface methodology was used to investigate the influence of factors on the responses. The optimized formulation displayed complete drug delivery and zero-order release rate. The TEM and particle size analysis indicated that the morphology of the resultant nanoparticle in the capsule was spherical shaped with a mean size of 252±19 nm. The in vivo test in beagle dogs demonstrated that the relative bioavailability of the novel system was 203.5% in comparison to that of the marketed preparation. The capsule successfully controlled the release of carvedilol and the fluctuation of plasma concentration was minimized. The system is a promising strategy to improve the oral bioavailability for poorly soluble drugs and preparing it into elementary osmotic pump conveniently.

  2. Characteristics of Photosystem II Behavior in Cotton (Gossypium hirsutum L.) Bract and Capsule Wall

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ya-li; LUO Hong-hai; HU Yuan-yuan; Reto J. Strasser; ZHANG Wang-feng

    2013-01-01

    Though bract and capsule wall of boll in cotton (Gossypium hirsutum L.) have different photosynthetic capacities, the features of photosystem II (PS II) in these organs are scarce. In this paper, chlorophyll a lfuorescence emission was measured to investigate the difference in the photosynthetic apparatus of dark-acclimated (JIP-test) and light-acclimated (light-saturation pulse method) bract and capsule wall. Compared with leaves, the oxygen evolving system of non-foliar organs had lower efifciency. The pool size of PS II electron acceptor of non-foliar organs was small, and the photochemical activity of leaves was higher than that of the bract and capsule wall. In regard to the photosystem I (PS I) electron acceptor side, the pool size of end electron acceptors of leaves was larger, and the quantum yield of electron transport from QA (PS II primary plastoquinone acceptor) further than the PS I electron acceptors of leaves was higher than that of bract and capsule wall. In all green organs, the actual quantum yield of photochemistry decreased with light. The thermal dissipation fraction of light absorbed by the PS II antennae was the highest in bract and the lowest in capsule wall relative to leaves. Compared with leaves, capsule wall was characterized by less constitutive thermal dissipation and via dissipation as lfuorescence emission. These results suggested that lower PS II photochemical activity in non-foliar organs may be result from limitations at the donor side of PS II and the acceptor sides of both photosystems.

  3. Capsule endoscopy in diagnosis of small bowel Crohn′s disease

    Institute of Scientific and Technical Information of China (English)

    Zhi-Zheng Ge; Yun-Biao Hu; Shu-Dong Xiao

    2004-01-01

    AIM: To evaluate the effectiveness of wireless capsule endoscopy in patients with suspected Crohn′s disease (CD)of the small bowel undetected by conventional modalities,and to determine the diagnostic yield of M2A Given Capsule.METHODS: From lay 2002 to April 2003, we prospectively examined 20 patients with suspected CD by capsule endoscopy. The patients had the following features:abdominal pain, weight loss, positive fecal occult blood test, iron deficiency anaemia, diarrhoea and fever. All the patients had normal results in small bowel series (SBS)and in upper and lower gastrointestinal endoscopy before they were examined. Mean duration of symptoms before diagnosis was 6.5 years.RESULTS: Of the 20 patients, 13 (65%) were diagnosed as CD of the small bowel according to the findings of M2A Given Capsule. The findings detected by the capsule were mucosal erosions (2 patients), aphthas (5 patients),nodularity (1 patient), large ulcers (2 patients), and ulcerated stenosis (3 patients). The distribution of the lesions was mainly in the distal part of the small bowel,and the mild degree of lesions was 54%.CONCLUSION: Wireless capsule endoscopy is effective in diagnosing patients with suspected CD undetected by conventional diagnostic methods. It can be used to detect early lesions in the small bowel of patients with CD.

  4. The application of GI-pill gastrointestinal electronic capsule combined with colonic transit test in patients with slow transit constipation%GI-pill胃肠电子胶囊与结肠运输试验联合检查在慢传输便秘中的应用价值

    Institute of Scientific and Technical Information of China (English)

    王永兵; 张根福; 罗芸葆; 李刚; 颜国正; 姜萍萍; 王志武

    2015-01-01

    目的 探讨GI-pill胃肠电子胶囊在慢传输型便秘中的应用价值. 方法 将81例排除出口梗阻型便秘和肠道器质性疾病,同意接受胃肠电子胶囊检测的慢性便秘患者,数字随机法分为两组,研究组42例,同时口服胃肠电子胶囊和不透X线颗粒胶囊;对照组39例单独口服不透X线颗粒胶囊;口服后2组患者均填写饮食、活动、休息等临床记录表,每隔24小时拍摄腹部X线立卧位平片,直至腹腔残留不透X线颗粒数小于4粒,研究组同时连续观察体外数据记录仪运行状态直至电子胶囊排出体外回收;对照分析2组结肠运输试验结果,统计分析GI-pill胃肠电子胶囊在体时间、胃、小肠、结肠通过时间,HAPCs数量、生理响应比. 结果 研究组和对照组结肠运输试验平均时间分别为4 .94 ±1 .31天和4 .85 ±1 .35天,右半结肠通过时间、左半结肠通过时间及直乙结肠通过时间分别是1.38 ±0.62天和1.35 ±0.53天,1.97 ±0.99天和2.02 ±0.90天,1.52 ±0.74天和1.58 ±0.71天,相比无统计学差异;研究组GI-pill胃肠电子胶囊在体时间与结肠运输试验时间分别为120.0 ±15.32小时和4.9 ±1.32天,胃肠电子胶囊在胃、小肠和结直肠的时间分别为5.83 ±3.12小时、8.75 ±4.01小时、94.7 ±17.63小时,HAPCs总数、群发HAPCs和生理响应比分别为14.2 ±5.14个、4.9 ±2.26个和39.20%. 全体患者研究期间无腹痛、呕吐、黑便等不适表现. 结论 GI-pill胃肠电子胶囊可连续评价慢传输便秘患者消化道动力特征,与结肠运输试验有很好的同一性,值得临床推广应用.%Objective To explore the application of GI-pill gastrointestinal electronic capsule in slow transit constipation .Methods 81 patients with slow transit constipation ,who had been ruled out outlet obstructive constipation and organic intestinal disease and agreed to move forward with the test of GI -pill gastrointestinal electronic capsule ,were assigned

  5. Colon Capsule Endoscopy: Detection of Colonic Polyps Compared with Conventional Colonoscopy and Visualization of Extracolonic Pathologies

    Directory of Open Access Journals (Sweden)

    Alexander F Hagel

    2014-01-01

    Full Text Available BACKGROUND: Conventional colonoscopy (CC is the gold standard for diagnostic examination of the colon. However, the overall acceptance of this procedure is low due to patient fears of complications or embarrassment. Colon capsule endoscopy (CCE represents a minimally invasive, patient-friendly procedure that offers complete visualization of the entire intestine.

  6. Capsule endoscopy in neoplastic diseases

    Institute of Scientific and Technical Information of China (English)

    Marco Pennazio; Emanuele Rondonotti; Roberto de Franchis

    2008-01-01

    Until recently,diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques.An array of new methods has recently been developed,increasing the possibility of detecting these tumors at an earlier stage.Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ,since it is non-invasive and enables the entire small bowel to be visualized.Highquality images of the small-bowel mucosa may be captured and small and fiat lesions recognized,without exposure to radiation.Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range,1.6%-2.4%)and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding.The majority of tumors identified by CE are malignant;many were unsuspected and not found by other methods.However,it remains difficult to identify pathology and tumor type based on the lesion's endoscopic appearance.Despite its limitations,CE provides crucial information leading in most cases to changes in subsequent patient management.Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms,ultimately resulting in a survival advantage and in cost savings,remains to be determined through carefully-designed studies.

  7. [The lateral splitting of the knee joint capsule for treatment of chondropathia patellae (author's transl)].

    Science.gov (United States)

    Dobler, R

    1977-06-26

    This is a report on the results of the lateral splitting of the knee-joint capsule for treatment of chondropathia patellae. The operative procedure is described. Pains relative to the patella syndrome, chondropathia patellae, forms of dysplasia of the patella and lateral dislocation of the patella are regarded as indications. 50 knee-joints were post-examined. 26% were without complaints, 54% showed improvement, 10% no change, 10% deteriorated. These results are comparable to those of other, more intensive surgery. Representing a comparatively minor operation, the lateral splitting of the capsule is therefore particularly recommended for young patients.

  8. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10(-5) to 10(-2) m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  9. Lubricin in human breast tissue expander capsules.

    Science.gov (United States)

    Cheriyan, Thomas; Guo, Lifei; Orgill, Dennis P; Padera, Robert F; Schmid, Thomas M; Spector, Myron

    2012-10-01

    Capsular contraction is the most common complication of breast reconstruction surgery. While presence of the contractile protein alpha smooth muscle actin (α-SMA) is considered among the causes of capsular contraction, the exact etiology and pathophysiology is not fully understood. The objective of this study was to investigate the possible role of lubricin in capsular formation and contraction by determining the presence and distribution of the lubricating protein lubricin in human breast tissue expander capsules. Related aims were to evaluate select histopathologic features of the capsules, and the percentage of cells expressing α-SMA, which reflects the myofibroblast phenotype. Capsules from tissue expanders were obtained from eight patients. Lubricin, at the tissue-implant interface, in the extracellular matrix, and in cells, and α-SMA-containing cells were evaluated immunohistochemically. The notable finding was that lubricin was identified in all tissue expander capsules: as a discrete layer at the tissue-implant interface, extracellular, and intracellular. There was a greater amount of lubricin in the extracellular matrix in the intimal-subintimal zone when compared with the tissue away from the implant. Varying degrees of synovial metaplasia were seen at the tissue-implant interface. α-SMA-containing cells were also seen in all but one patient. The findings might help us better understand factors involved in capsule formation.

  10. 21 CFR 343.90 - Dissolution and drug release testing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Dissolution and drug release testing. 343.90...-COUNTER HUMAN USE Testing Procedures § 343.90 Dissolution and drug release testing. (a) [Reserved] (b) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in...

  11. Employee Drug Testing. Testimony. Statement (Summary) of L. Nye Stevens, Associate Director, General Government Division, before the Subcommittee on Employment Opportunities, Committee on Education and Labor, House of Representatives.

    Science.gov (United States)

    Stevens, L. Nye

    At the request of Congress, the General Accounting Office (GAO) conducted a study of drug testing of employees by employers. To identify and obtain the most recent surveys on drug testing policies and practices in the private sector, the GAO searched 14 computerized bibliographic files and discussed information needs with representatives of 35…

  12. Irradiation of Polyimide and Neutron Poison Materials by Using a HANARO Capsule

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Cho, M. S.; Shin, Y. T.; Kim, B. G.; Seo, C. G.; Kim, Y. K. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    A material capsule system has been developed for an irradiation test of non-fissile materials in HANARO (High flux Advanced Neutron Application ReactOr).This capsule system has been actively utilized for the various material irradiation tests requested by users from research institutes, universities, and the industries. The capsules were mainly designed for an irradiation of the RPV (Reactor Pressure Vessel) and reactor core materials, and Zr-based alloys of parts of nuclear fuel assembly. Recently, irradiation tests of neutron poison materials and Polyimide were requested by Westinghouse Electric Company (WEC) and Hanyang University, respectively. As a candidate material of control rod of AP1000 reactor, Ag and Ag-In-Cd alloys were requested to be irradiated in HANARO by WEC. Polyimide has been studied as a shielding material against thermal and fast neutrons. The irradiation of these new materials which might affect the safety of a reactor was carried out for the first time in HANARO. As a preliminary test, small amount of these materials were determined to be inserted in a KNF (Korea Nuclear Fuel) irradiation capsule of 07M-13N. Due to the new materials, the irradiation test of the 07M-13N capsule was examined and approved by the 'HANARO Safety Review Committee'. The 07M-13N capsule was safely irradiated for 95.19 days (4 cycles) in the CT test hole of HANARO of a 30MW thermal output at 230{approx}420 .deg. C. The specimens of these new materials were irradiated up to a maximum fast neutron fluence of 1.13x1021(n/cm{sup 2}) (E>1.0MeV) and the dpa of the irradiated specimens were evaluated as 1.87.

  13. Spectral measurements of asymmetrically irradiated capsule backlighters

    Science.gov (United States)

    Keiter, P. A.; Drake, R. P.

    2016-11-01

    Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies [J. F. Hansen et al., Rev. Sci. Instrum. 79, 013504 (2008)]. Ideally one irradiates the capsule backlighter symmetrically, however, in complex experimental geometries, this is not always possible. In recent experiments we irradiated capsule backlighters asymmetrically and measured the x-ray spectrum from multiple directions. We will present time-integrated spectra over the photon energy range of 2-13 keV and time-resolved spectra over the photon energy range of 2-3 keV. We will compare the spectra from different lines of sight to determine if the laser asymmetry results in an angular dependence in the x-ray emission.

  14. Unsteady Pressures on a Generic Capsule Shape

    Science.gov (United States)

    Burnside, Nathan; Ross, James C.

    2015-01-01

    While developing the aerodynamic database for the Orion spacecraft, the low-speed flight regime (transonic and below) proved to be the most difficult to predict and measure accurately. The flow over the capsule heat shield in descent flight was particularly troublesome for both computational and experimental efforts due to its unsteady nature and uncertainty about the boundary layer state. The data described here were acquired as part of a study to improve the understanding of the overall flow around a generic capsule. The unsteady pressure measurements acquired on a generic capsule shape are presented along with a discussion about the effects of various flight conditions and heat-shield surface roughness on the resulting pressure fluctuations.

  15. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  16. Video capsule endoscopy in inflammatory bowel disease

    Science.gov (United States)

    Collins, Paul D

    2016-01-01

    Video capsule endoscopy (VCE) has evolved to become an important tool for the non-invasive examination of the small bowel, which hitherto had been relatively inaccessible to direct visualisation. VCE has been shown to play a role in monitoring the activity of small bowel Crohn’s disease and can be used to assess the response to anti-inflammatory treatment in Crohn’s disease. For those patients with Crohn’s disease who have undergone an intestinal resection, VCE has been assessed as a tool to detect post-operative recurrence. VCE may also aid in the reclassification of patients with a diagnosis of Inflammatory Bowel Disease Unclassified to Crohn’s disease. The evolution of colon capsule endoscopy (CCE) has expanded the application of this technology further. The use of CCE to assess the activity of ulcerative colitis has been described. This advance in capsule technology has also fuelled interest in its potential role as a minimally invasive tool to assess the whole of GI tract opening the possibility of its use for the panenteric assessment of Crohn’s disease. VCE is a safe procedure. However, the risk of a retained capsule is higher in patients with suspected or confirmed Crohn’s disease compared with patients having VCE examination for other indications. A retained video capsule is rare after successful passage of a patency capsule which may be utilised to pre-screen patients undergoing VCE. This paper describes the use of VCE in the assessment of inflammatory bowel disease. PMID:27499830

  17. Capsules with external navigation and triggered release.

    Science.gov (United States)

    Shchukin, Dmitry G; Shchukina, Elena

    2014-10-01

    Encapsulation is an important technology for pharmaceutical industry, food production, et cetera. Its current level of development requires capsule functionalization. One of the interesting ideas to provide new functionality to the microcapsule and nanocapsule is layer-by-layer deposition of functional species. This technique provides step-by-step adsorption of various species (polyelectrolytes, nanoparticles, proteins) when the layer growth is controlled by electrostatic, hydrogen bonding, hydrophobic forces and forming multilayer shells with nanometer precision. This review article introduces recent achievements of layer-by-layer technique attaining external navigation ability and release properties the capsule shell.

  18. [Anti-platelet aggregation bioassay based quality control for XST capsules].

    Science.gov (United States)

    Han, Bing; Mao, Xin; Han, Shu-xian; Chen, Ying; Xiang, Yan-hua; Ge, Yi-meng; Liao, Fu-long; You, Yun

    2015-12-01

    A in vitro platelet aggregation bioassay was developed for the quality control of XST capsules. The in vitro anti-platelet aggregation effect in rats was observed to detect the bioactivity of XST capsules. Panax notoginseng saponins and Xuesaitong lyophilizedpowder for injection were taken as standard control substances to determine the potency. According to the results, XST capsules showeda significant inhibitory effect on thrombin-induced platelet aggregation in a dose-dependent manner. The in vitro anti-platelet activity oflyophilized powder for injection was stabler than that of Panax notoginseng saponins, and so suitable to serve as a standard control substance. The biological potency of XST capsules compared with standard control substance was detected by using parallel line assay. According to the results, the established bioassay method had a good repeatability (RSD 2.92%). The sample test results could pass thereliability test(linear deviation P > 0.05, parallel deviation P > 0.05). This bioassay method could be used as one of the complementary quality control methods for XST capsules.

  19. Application of a frequency distribution method for determining instars of the beet armyworm (Lepidoptera: Noctuidae) from widths of cast head capsules

    Science.gov (United States)

    Y. Chen; S. J. Seybold

    2013-01-01

    Instar determination of field-collected insect larvae has generally been based on the analysis of head capsule width frequency distributions or bivariate plotting, but few studies have tested the validity of such methods. We used head capsules from exuviae of known instars of the beet armyworm, Spodoptera exigua (Hübner) (Lepidoptera: Noctuidae),...

  20. Tank-treading and tumbling frequencies of capsules and red blood cells.

    Science.gov (United States)

    Yazdani, Alireza Z K; Kalluri, R Murthy; Bagchi, Prosenjit

    2011-04-01

    This study is motivated in part by the discrepancy that exists in the literature with regard to the dependence of the tank-treading frequency of red blood cells on the shear rate and suspending medium viscosity. Here we consider three-dimensional numerical simulations of deformable capsules of initially spherical and oblate spheroidal shapes and biconcave discoid representing the red blood cell resting shape. By considering a much broader range of the viscosity ratio (ratio of capsule or cell interior to suspending fluid viscosity), shear rate, and aspect ratio (ratio of minor to major axes) than that considered in the previous experiments, we find several new characteristics of the tank-treading and tumbling frequencies that have not been reported earlier. These new characteristics are the result of the large shape deformation and the coupling between shape and angular oscillations of the capsules or cells. For the spherical and oblate spheroidal capsules, the tank-treading frequency shows a nonmonotonic trend that is characterized by an initial decrease leading to a minimum followed by an increase with increasing viscosity ratio. For red blood cells, we find two regimes of the viscosity dependence of the tank-treading frequency: an exponential regime in which the tank-treading frequency decreases at a slower rate with increasing viscosity ratio, and a logarithmic range in which it decreases at a much faster rate. While this trend agrees well with different theoretical models of shape-preserving capsules, it was not evident in previous experimental results. When the shear rate dependence is considered, the tank-treading frequency of red blood cells and capsules of highly elongated initial shapes exhibits a nonmonotonic trend that is characterized by an initial increase leading to a maximum followed by a sharp decrease with decreasing shear rate. This anomalous behavior of the tank-treading frequency is shown to be due to a breathing-like dynamics of the capsule or

  1. Development of Naphthalene PLIF for Visualizing Ablation Products From a Space Capsule Heat Shield

    Science.gov (United States)

    Combs, C. S.; Clemens, N. T.; Danehy, P. M.

    2014-01-01

    The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield. To better design this heat shield and others that will undergo planetary entry, an improved understanding of the ablation process would be beneficial. Here, a technique developed at The University of Texas at Austin that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to enable visualization of the ablation products in a hypersonic flow is applied. Although high-temperature ablation is difficult and expensive to recreate in a laboratory environment, low-temperature sublimation creates a limited physics problem that can be used to explore ablation-product transport in a hypersonic flow-field. In the current work, a subscale capsule reentry vehicle model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel. The PLIF technique provides images of the spatial distribution of sublimated naphthalene in the heat-shield boundary layer, separated shear layer, and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. PLIF images have shown high concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure. It was shown that, in general, the capsule shear layer appears to be more unsteady at lower angels of attack. The PLIF images demonstrated that during a wind tunnel run, as the model heated up, the rate of naphthalene ablation increased, since the PLIF signal increased steadily over the course of a run. Additionally, the shear layer became increasingly unsteady over the course of a wind tunnel run, likely because of increased surface roughness but also possibly because of the increased blowing. Regions with a relatively low concentration of naphthalene were also identified in the capsule backshell

  2. Biodistribution of polymer hydrogel capsules for the delivery of therapeutics.

    Science.gov (United States)

    Hinton, Tracey M; Monaghan, Paul; Green, Diane; Kooijmans, Sander A A; Shi, Shuning; Breheney, Kerry; Tizard, Mark; Nicolazzo, Joseph A; Zelikin, Alexander N; Wark, Kim

    2012-09-01

    A key phase in the development of intelligently designed nanoparticle delivery vehicles for new therapeutic agents is to gain an understanding of their interaction with tissues and cells. We report a series of in vitro and in vivo experiments aimed at tracking a potential delivery vehicle for therapeutic agents, including vaccine peptides and drugs derived from poly(methacrylic acid) hydrogel capsules in certain organs and cell types. For the in vitro studies, two immortal liver-derived cell lines (Huh7 and Hepa1-6) and primary cultures of mouse hepatocytes were incubated with Alexa 647 labelled fluorescent capsules to track their internalization and intracellular distribution by confocal microscopy. Capsules, 500nm in diameter, were taken up into the cells in a time-dependent manner in all three cell lines. Capsules were observed in plasma membrane-derived vesicles within the cells. After 24h a significant proportion of the capsules was observed in lysosomes. To understand the behaviour of the capsules in vivo, Alexa 488 labelled fluorescent capsules were intravenously injected into Sprague-Dawley rats and after 24h the fate of the capsules in a number of organs was determined by flow cytometry and confocal microscopy. By flow cytometry, the majority of the capsules were detected in the spleen whilst similar numbers were found in the lung and liver. By confocal microscopy, the majority of the capsules were found in the liver and spleen with significantly less capsules in the lung, heart and kidney. Colocalization of capsules with cell-type specific markers indicated that in lung, heart and kidney, the majority of the capsules were located in endothelial cells. In the spleen ~50% of the capsules were found in CD163-positive cells, whereas in the liver, almost all capsules were located in CD163-positive cells, indicating uptake by Kupffer cells. Electron microscopy confirmed the presence of capsules within Kupffer cells. Crown Copyright © 2012. Published by

  3. Capsule endoscopy: Current status in obscure gastrointestinal bleeding

    Institute of Scientific and Technical Information of China (English)

    R Gupta; Nageshwar Duvvuru Reddy

    2007-01-01

    Capsule endoscopy (CE) is a safe, non invasive diagnostic modality for the evaluation of small bowel lesions. Obscure gastrointestinal bleeding (OGIB) is one of the most important indications of capsule endoscopy.Capsule endoscopy has a very high diagnostic yield especially if the bleeding is ongoing. This technique appears to be superior to other techniques for the detection of suspected lesions and the source of bleeding. Capsule endoscopy has been shown to change the outcome in patients with obscure gastrointestinal (GI)bleed.

  4. The influence of polymorphism on the manufacturability and in vitro dissolution of sulindac-containing hard gelatin capsules.

    Science.gov (United States)

    Guadalupe Sánchez-González, Elizabeth; Yépez-Mulia, Lilian; Jesús Hernández-Abad, Vicente; Jung Cook, Helgi

    2015-05-01

    Drug polymorphism could affect drug product dissolution, manufacturability, stability and bioavailability/bioequivalence. The impact of polymorphism on the manufacturability and in vitro dissolution profiles of sulindac capsules has not been studied yet. To evaluate the impact of polymorphism on the manufacturability and in vitro dissolution of sulindac hard gelatin capsules. Sulindac crystal forms I and II (SLDI and SLDII, respectively) were prepared and characterized. Powder formulations containing one of the polymorphs, lactose and magnesium stearate (at three different levels) were prepared and their flow properties determined. Hard gelatin capsules were filled with the formulations and tested for fill-weight variations. Drug dissolution for SLDI- and SLDII-containing hard gelatin capsules was determined. Differences in flow properties for each polymorph were observed, as well as for their formulations, which in turn affected capsule weight homogeneity. Statistically significant differences in the rate and extent of drug release were observed between SLDI- and SLDII-containing capsules. Formulations containing SLDI showed a better manufacturability and a better dissolution profile than those with SLDII. Sulindac crystalline form I was the best candidate for hard gelatin capsule formulation because of its technological and in vitro dissolution properties.

  5. 21 CFR 520.90a - Ampicillin capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Ampicillin capsules. 520.90a Section 520.90a Food... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.90a Ampicillin capsules. (a) Specifications. Each capsule contains 125 milligrams or 250 milligrams of ampicillin. (b) Sponsor. See No. 000008...

  6. 21 CFR 520.580 - Dichlorophene and toluene capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dichlorophene and toluene capsules. 520.580 Section 520.580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dichlorophene and toluene capsules. (a) Specifications. Each soft gelatin capsule contains 50 milligrams of...

  7. 21 CFR 520.1920 - Prochlorperazine, isopropamide sustained release capsules.

    Science.gov (United States)

    2010-04-01

    ... capsules. 520.1920 Section 520.1920 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... § 520.1920 Prochlorperazine, isopropamide sustained release capsules. (a) Specifications. Prochlorperazine, isopropamide sustained release capsules contain either: (1) 3.33 milligrams of prochlorperazine...

  8. 21 CFR 520.260 - n-Butyl chloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...

  9. 21 CFR 520.1804 - Piperazine phosphate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Piperazine phosphate capsules. 520.1804 Section 520.1804 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... phosphate capsules. (a) Specifications. Each capsule contains 120, 300, or 600 milligrams of piperazine...

  10. 21 CFR 520.90c - Ampicillin trihydrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Ampicillin trihydrate capsules. 520.90c Section 520.90c Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... trihydrate capsules. (a) Specifications. Each capsule contains ampicillin trihydrate equivalent to 125, 250...

  11. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  12. 21 CFR 520.622d - Diethylcarbamazine citrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Diethylcarbamazine citrate capsules. 520.622d Section 520.622d Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Diethylcarbamazine citrate capsules. (a) Specifications. Each capsule contains 12.5, 50, 200, or 400 milligrams (mg...

  13. 21 CFR 872.3110 - Dental amalgam capsule.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with...

  14. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    The application relates to an ingestible capsule (102) for delivery of a substance e.g. a pharmaceutical drug, to a human or animal. The ingestible capsule comprises a capsule wall structure (202) forming a substantially sealed reservoir or lumen holding the substance (204). An electrical resonan...

  15. Theoretical study of symmetry of flux onto a capsule

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Hao; Wu, Changshu; Zou, Shiyang, E-mail: duan-hao@iapcm.ac.cn [Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China); Pei, Wenbing [Shanghai Institute of Laser Plasma, China Academy of Engineering Physics, Shanghai 201800 (China)

    2015-09-15

    An analytic model to describe the flux asymmetry onto a capsule based on the viewfactor approximation is developed and verified with numerical simulations. By using a nested spheres technique to represent the various sources of flux asymmetry, the model can treat spherically and cylindrically symmetric hohlraums, e.g., cylinder, elliptic, and rugby. This approach includes the more realistic case of frequency-dependent flux asymmetry compared with the more standard frequency-integrated or single-frequency approaches [D. W. Phillion and S. M. Pollaine, Phys. Plasmas 1, 2963 (1994)]. Correspondingly, the approach can be used to assess x-ray preheat asymmetry generated from localized laser absorption in the high-Z hohlraum wall. For spherical hohlraums with 4, 6, or 8 laser entrance holes (LEHs), an optimal configuration of LEHs, laser spot placement, and angle-of-incidence of the single-ringed laser beams is defined. An analogy between minimizing the flux asymmetry onto a capsule and the Thomson problem of point charge placement on a sphere for minimized energy is shown.

  16. Electrohydrodynamic deformation of capsules in electric field

    Science.gov (United States)

    Das, Sudip; Thaokar, Rochish

    2016-11-01

    Micron size capsules are abundant in natural, technological and biological processes but they still require extensive investigation for better understanding of their mechanical behavior. A spherical capusle containing a Newtonian fluid bounded by a viscoelastic membrane and immersed in another Newtonian fluid, and subject to electric field is considered. Discontinuity of electrical properties such as conductivity and permittivity leads to a net Maxwell stress at the capsule interface. In response the capsule undergoes elastic deformation, leading to strain fields and elastic stresses that can balance the applied forces. We investigate this problem with fully resolved hydrodynamics in the Stokes flow limit and electrostatics using the capacitance model. Effect of AC, DC and pulsed DC fields is investigated. Our results show that membrane electrical properties have a huge impact on the equilibrium deformation as well as on the break up of capsules. Our results match with the literature results in the limit of high conductance of the membrane. Analytical theory is employed using spherical harmonics and numerical investigations are conducted using the Boundary integral method.

  17. Student Mobility. Information Capsule. Volume 0608

    Science.gov (United States)

    Blazer, Christie

    2007-01-01

    Mobility, rather than stability, has become the norm for students in schools across the United States. The student mobility rate is now higher in the United States than in any other industrialized country. This Information Capsule discusses the reasons for student mobility and the characteristics of highly mobile students and families. Research…

  18. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  19. Capsules with evolving brittleness to resist the preparation of self-healing concrete

    Directory of Open Access Journals (Sweden)

    Gruyaert, E.

    2016-09-01

    Full Text Available Capsules for self-healing concrete have to possess multifunctional properties and it would be an enormous advantage in the valorization process when they could also be mixed in. Therefore, we aimed to develop capsules with evolving brittleness. Capsules with high initial flexibility were prepared by adding a plasticizer to an ethyl cellulose matrix. During hardening of the concrete, the plasticizing agent should leach out to the moist environment yielding more brittle capsules which break upon crack appearance. The tested capsules could easily be mixed in during concrete production. However, incompatibility issues between the capsule wall and the inner polymeric healing agent appeared. Moreover, the capsules became insufficiently brittle and the bond strength to the cementitious matrix was too weak. Consequently, multilayer capsules were tested. These capsules had a high impact resistance to endure concrete mixing and were able to break upon crack formation.Las cápsulas para la auto-reparación del hormigón tienen que poseer propiedades multifuncionales. Una enorme ventaja en el proceso para su valorización se obtendría si aquellas pudieran resistir con éxito el mezclado. Por lo tanto, nos propusimos desarrollar cápsulas cuya fragilidad evoluciona. Cápsulas con una alta flexibilidad inicial se prepararon mediante la adición de un plastificante a una matriz de etil celulosa. Durante el endurecimiento del hormigón, el agente plastificante debe filtrarse hacia el medio ambiente húmedo produciendo cápsulas más frágiles que se rompen con el surgimiento de fisuras. Las cápsulas pudieron ser fácilmente mezcladas durante la producción de hormigón. Sin embargo, aparecieron problemas de incompatibilidad entre la pared de la cápsula y el agente de curación polimérico interior. Por otra parte, las cápsulas se comportaron insuficientemente frágiles y con una baja adherencia hacia la matriz cementicia. En consecuencia, se probaron las c

  20. Novel anisotropic continuum-discrete damage model capable of representing localized failure of massive structures. Part II: identification from tests under heterogeneous stress field

    CERN Document Server

    Kucerova, A; Ibrahimbegovic, A; Zeman, J; Bittnar, Z

    2009-01-01

    In Part I of this paper we have presented a simple model capable of describing the localized failure of a massive structure. In this part, we discuss the identification of the model parameters from two kinds of experiments: a uniaxial tensile test and a three-point bending test. The former is used only for illustration of material parameter response dependence, and we focus mostly upon the latter, discussing the inverse optimization problem for which the specimen is subjected to a heterogeneous stress field.

  1. Sertoli-Leydig cell tumors: hormonal profile after dynamic test with GnRH analogue: triptorelin represents a useful tool to evaluate tumoral hyperandrogenism.

    Science.gov (United States)

    Turra, J; Granzotto, M; Gallea, M; Faggian, D; Conte, L; Litta, P; Vettor, R; Mioni, R

    2015-01-01

    We report the case of a 15-year-old woman with signs of hyperandrogenism affected by a Sertoli-Leydig cell tumor (SLCT). In our patient, blood analysis showed a high testosterone (T) level (T: 8.53 nmol/L; nv analogue test demonstrated an exaggerated secretion of 17-hydroxyprogesterone (OHP), T, and androstenedione (A) by the ovary after stimulation. We compared the GnRH-analogue test of our patient with that obtained in a group of normal and healthy women (no. 8 subjects, 16-26 years old), men (no. 4 subjects, 18-28 years old), and in a group of PCOS patients with age and body weight compared. We found in our patient a value of OHP, 17-beta estradiol (E2) and T, from 2 to 18 times higher than healthy women. When we compared our patient with healthy men, we differently observed a comparable response of T. The response of our patient was also comparable with that observed in the PCOS group for E2. During the post-surgical follow up, the GnRH-analogue test of our patient showed a response of OHP, T, and E2 comparable with that of the PCOS group. The GnRH-analogue test is a useful tool to characterize steroidogenesis in SLCT.

  2. Predicting Student Grade Point Average at a Community College from Scholastic Aptitude Tests and from Measures Representing Three Constructs in Vroom's Expectancy Theory Model of Motivation.

    Science.gov (United States)

    Malloch, Douglas C.; Michael, William B.

    1981-01-01

    This study was designed to determine whether an unweighted linear combination of community college students' scores on standardized achievement tests and a measure of motivational constructs derived from Vroom's expectance theory model of motivation was predictive of academic success (grade point average earned during one quarter of an academic…

  3. Predicting Student Grade Point Average at a Community College from Scholastic Aptitude Tests and from Measures Representing Three Constructs in Vroom's Expectancy Theory Model of Motivation.

    Science.gov (United States)

    Malloch, Douglas C.; Michael, William B.

    1981-01-01

    This study was designed to determine whether an unweighted linear combination of community college students' scores on standardized achievement tests and a measure of motivational constructs derived from Vroom's expectance theory model of motivation was predictive of academic success (grade point average earned during one quarter of an academic…

  4. Kinetic simulation of hydrodynamic equivalent capsule implosions

    Science.gov (United States)

    Kwan, Thomas; Le, Ari; Schmitt, Mark; Herrmann, Hans

    2016-10-01

    We have carried out simulations of direct-drive hydrodynamic equivalent capsule implosion experiments conducted on Omega laser facility at the Laboratory of Laser Energetics of the University of Rochester. The capsules had a glass shell (SiO2) 4.87 μm with an inner diameter of 1086 μm. One was filled with deuterium (D) and tritium (T) at 6.635 and 2.475 atmospheric pressure respectively. The other capsule with D, T, and He-3 at 2.475, 2.475, and 5.55 atmospheric pressure respectively. The capsules were imploded with 60 laser beams with a square pulse length of 0.6ns of total energy of 15.6 kJ. One-dimensional radiation hydrodynamic calculations with HYDRA and kinetic particle/hybrid simulations with LSP are carried out for the post-shot analysis. HYDRA outputs at 0.6ns are linked to LSP, in which the electrons are treated as a fluid while all the ion dynamics is simulated by the standard particle-in-cell technique. Additionally, simulations with the new photon package in LSP are initiated at the beginning of the implosion to include the implosion phase of the capsule. The simulation results of density, temperature, and velocity profiles of the electrons, D, T, He-3, and SiO2species are compared with HYDRA. Detail comparisons among the kinetic simulations, rad-hydro simulations, and experimental results of neutron yield, yield ratio, fusion burn histories, and shell convergence will be presented to assess plasma kinetic effects. Work performed under the auspices of the US DOE by the Los Alamos National Laboratory under Contract No. W7405-ENG-36.

  5. Cotton fabric functionalisation with menthol/PCL micro- and nano-capsules for comfort improvement.

    Science.gov (United States)

    Mossotti, Raffaella; Ferri, Ada; Innocenti, Riccardo; Zelenková, Tereza; Dotti, Francesca; Marchisio, Daniele L; Barresi, Antonello A

    2015-01-01

    Cotton functionalisation with poly-ɛ-caprolactone (PCL) micro- and nano-capsules containing menthol was carried out with the aim of introducing a long-lasting refreshing sensation. The preparation of the polymer micro- and nano-capsules was carried out by solvent displacement technique. A confined impinging jets mixer was used in order to ensure fast mixing and generate a homogeneous environment where PCL and menthol can self-assemble. The micro- and nano-capsules and the functionalised fabrics were characterised by means of DSC, FT-IR spectroscopy and SEM imaging. Micro- and nano-capsules of different size, from about 200 to about 1200 nm, were obtained varying menthol to PCL ratio (from 0.76 to 8), overall concentration and flow rate (i.e. mixing conditions). The inclusion of menthol was confirmed by DSC analysis. A patch test was carried out by 10 volunteers. Micro-capsules were found to be effective in conferring the fabric a refreshing sensation without altering skin physiology.

  6. Cryptococcus neoformans capsule protects cell from oxygen reactive species generated by antimicrobial photodynamic inactivation

    Science.gov (United States)

    Prates, Renato Araujo; Hamblin, Michael R.; Kato, Ilka T.; Fuchs, Beth; Mylonakis, Eleytherios; Simões Ribeiro, Martha; Tegos, George

    2011-03-01

    Antimicrobial photodynamic inactivation (APDI) is based on the utilization of substances that can photosensitize biological tissues and are capable of being activated in the presence of light. Cryptococcus neoformans is an yeast surrounded by a capsule composed primarily of glucoronoxylomannan that plays an important role in its virulence. This yeast causes infection on skin, lungs and brain that can be associated with neurological sequelae and neurosurgical interventions, and its conventional treatment requires prolonged antifungal therapy, which presents important adverse effects. The aim of this study was to evaluate the protective effect of Cryptococcus neoformans capsule against reactive oxygen species generated by APDI. Cryptococcus neoformans KN99α, which is a strain able to produce capsule, and CAP59 that does not present capsule production were submitted to APDI using methylene blue (MB), rose bengal (RB), and pL-ce6 as photosensitizers (PS). Then microbial inactivation was evaluated by counting colony form units following APDI and confocal laser scanning microscopy (CLSM) illustrated localization as well as the preferential accumulation of PS into the fungal cells. C. neoformans KN99α was more resistant to APDI than CAP59 for all PSs tested. CLSM showed incorporation of MB and RB into the cytoplasm and a preferential uptake in mitochondria. A nuclear accumulation of MB was also observed. Contrarily, pL-ce6 appears accumulated in cell wall and cell membrane and minimal florescence was observed inside the fungal cells. In conclusion, the ability of C. neoformans to form capsule enhances survival following APDI.

  7. An empirical study of the toxic capsule crisis in China: risk perceptions and behavioral responses.

    Science.gov (United States)

    Feng, Tianjun; Keller, L Robin; Wu, Ping; Xu, Yifan

    2014-04-01

    The outbreak of the toxic capsule crisis during April 2012 aroused widespread public concern about the risk of chromium-contaminated capsules and drug safety in China. In this article, we develop a conceptual model to investigate risk perceptions of the pharmaceutical drug capsules and behavioral responses to the toxic capsule crisis and the relationship between associated factors and these two variables. An online survey was conducted to test the model, including questions on the measures of perceived efficacy of the countermeasures, trust in the State FDA (Food and Drug Administration), trust in the pharmaceutical companies, trust in the pharmaceutical capsule producers, risk perception, concern, need for information, information seeking, and risk avoidance. In general, participants reported higher levels of risk perception, concern, and risk avoidance, and lower levels of trust in the three different stakeholders. The results from the structural equation modeling procedure suggest that perceived efficacy of the countermeasures is a predictor of each of the three trust variables; however, only trust in the State FDA has a dampening impact on risk perception. Both risk perception and information seeking are significant determinants of risk avoidance. Risk perception is also positively related to concern. Information seeking is positively related to both concern and need for information. The theoretical and policy implications are also discussed.

  8. Utility of MR arthrography in the diagnosis of adhesive capsulitis

    Energy Technology Data Exchange (ETDEWEB)

    Manton, G.L.; Schweitzer, M.E.; Weishaupt, D.; Karasick, D. [Dept. of Radiology, Thomas Jefferson Univ. Hospital, Philadelphia, PA (United States)

    2001-06-01

    Objective. Arthrographically, adhesive capsulitis is characterized by decreased joint volume; histologically, the capsule and synovium are thickened. We therefore compared using MR arthrography the joint volumes and capsule/synovial thickness of patients with and without adhesive capsulitis in order to assess the utility of MR arthrography in diagnosing adhesive capsulitis.Design and patients. The 1.5 T MR arthrography images of 28 subjects with (n=9) and without (n=19) adhesive capsulitis were compared. Adhe- sive capsulitis was diagnosed when there was an injected glenohumeral joint volume of less than 10 ml. Two masked observers working in consensus assessed the images for the relative amount of fluid in the biceps tendon sheath and axillary recess, corrugation at the margin of the capsule, capsule/synovial thickness, abnormalities of the rotator interval capsule, and for the presence of a cuff tear.Results. There was a trend towards differences in capsular and synovial thickness (P>0.07) between the subjects with and without adhesive capsulitis; however, the controls had thicker synovium/capsules. Surprisingly, the amount of fluid in the axillary recess and biceps tendon sheath was not significantly different between the groups (P>0.25). There were more tears of the rotator cuff in controls than in patients with adhesive capsulitis (6, 3 vs 1, 1: complete, partial). Also, both corrugation (7 vs 0) and interval abnormalities (7 vs 0) were more common in the controls.Conclusion. There appear to be no useful MR arthrographic signs of adhesive capsulitis. Capsular/synovial thickness, static fluid volume, and the presence of corrugation are inconclusive as MR arthrographic signs for distinguishing shoulders with adhesive capsulitis from those without. (orig.)

  9. 3D numerical simulations of vesicle and inextensible capsule dynamics

    Science.gov (United States)

    Farutin, Alexander; Biben, Thierry; Misbah, Chaouqi

    2014-10-01

    Vesicles are locally-inextensible fluid membranes, capsules are endowed with in-plane shear elasticity mimicking the cytoskeleton of red blood cells (RBCs), but are extensible, while RBCs are inextensible. We use boundary integral (BI) methods based on the Green function techniques to model and solve numerically their dynamics. We regularize the single layer integral by subtraction of exact identities for the terms involving the normal and the tangential components of the force. The stability and precision of BI calculation is enhanced by taking advantage of additional quadrature nodes located in vertices of an auxiliary mesh, constructed by a standard refinement procedure from the main mesh. We extend the partition of unity technique to boundary integral calculation on triangular meshes. The proposed algorithm offers the same treatment of near-singular integration regardless whether the source and the target points belong to the same surface or not. Bending forces are calculated by using expressions derived from differential geometry. Membrane incompressibility is handled by using two penalization parameters per suspended entity: one for deviation of the global area from prescribed value and another for the sum of squares of local strains defined on each vertex. Extensible or inextensible capsules, a model of RBC, are studied by storing the position in the reference configuration for each vertex. The elastic force is then calculated by direct variation of the elastic energy. Various nonequilibrium physical examples on vesicles and capsules will be presented and the convergence and precision tests highlighted. Overall, a good convergence is observed with numerical error inversely proportional to the number of vertices used for surface discretization, the highest order of convergence allowed by piece-wise linear interpolation of the surface.

  10. Anti-proliferative effect of olmesartan on Tenon's capsule fibroblasts

    Directory of Open Access Journals (Sweden)

    Xuan Wang

    2016-05-01

    Full Text Available AIM: To evaluate the inhibitive effect of olmesartan to fibroblast proliferation and the anti-scarring effect in Tenon’s capsule, both in vitro and in vivo. METHODS: Human primary Tenon’s capsule fibroblasts were cultured in vitro, treated with up titrating concentrations of olmesartan. The rate of inhibition was tested with methyl thiazol tetrazolium (MTT method. Real-time PCR was performed to analyze changes in mRNA expressions of the fibrosis-related factors: matrix metalloproteinase-2 (MMP-2, tissue inhibitor of metalloproteinase (TIMP-1,2 and proliferating cell nuclear antigen (PCNA. Thirty rabbits were divided into 5 groups (3, 7, 14, 21, and 28d. A rabbit conjunctiva flap model was created in each eye. Olmesartan solution was injected subconjunctivally and then evaluated its anti-proliferation and anti-fibrosis effects through the histological morphology and immunohistochemistry of MMP-2 and PCNA in each group. Only the 7d group was treated with Masson’s trichrome to compare the neovascularization in the subconjunctiva area. RESULTS: In vitro, cultured Tenon's capsule human fibroblasts showed a dose dependent inhibition by olmesartan in MTT. Olmesartan reduced mRNA expressions of MMP-2 and PCNA but increased mRNA expressions of TIMP-1 and TIMP-2. In vivo, the rabbit eyes treated with olmesartan at 3rd, 7th, 14th and 21st days demonstrated a significant reduced expressions of MMP-2 and PCNA compared with control eye, no significant difference observed in 28th day group. The cellular proliferation and neovascularization was suppressed by olmesartan in Masson’s trichrome observation. CONCLUSION: By inhibiting fibroblasts in vitro and in vivo, olmesartan prevents the proliferation and activity of fibroblasts in scar tissue formation, which might benefit glaucoma filtering surgery.

  11. Anti-proliferative effect of olmesartan on Tenon's capsule fibroblasts.

    Science.gov (United States)

    Wang, Xuan; Fan, Ya-Zhi; Yao, Liang; Wang, Jian-Ming

    2016-01-01

    To evaluate the inhibitive effect of olmesartan to fibroblast proliferation and the anti-scarring effect in Tenon's capsule, both in vitro and in vivo. Human primary Tenon's capsule fibroblasts were cultured in vitro, treated with up titrating concentrations of olmesartan. The rate of inhibition was tested with methyl thiazol tetrazolium (MTT) method. Real-time PCR was performed to analyze changes in mRNA expressions of the fibrosis-related factors: matrix metalloproteinase-2 (MMP-2), tissue inhibitor of metalloproteinase (TIMP-1,2) and proliferating cell nuclear antigen (PCNA). Thirty rabbits were divided into 5 groups (3, 7, 14, 21, and 28d). A rabbit conjunctiva flap model was created in each eye. Olmesartan solution was injected subconjunctivally and then evaluated its anti-proliferation and anti-fibrosis effects through the histological morphology and immunohistochemistry of MMP-2 and PCNA in each group. Only the 7d group was treated with Masson's trichrome to compare the neovascularization in the subconjunctiva area. In vitro, cultured Tenon's capsule human fibroblasts showed a dose dependent inhibition by olmesartan in MTT. Olmesartan reduced mRNA expressions of MMP-2 and PCNA but increased mRNA expressions of TIMP-1 and TIMP-2. In vivo, the rabbit eyes treated with olmesartan at 3(rd), 7(th), 14(th) and 21(st) days demonstrated a significant reduced expressions of MMP-2 and PCNA compared with control eye, no significant difference observed in 28(th) day group. The cellular proliferation and neovascularization was suppressed by olmesartan in Masson's trichrome observation. By inhibiting fibroblasts in vitro and in vivo, olmesartan prevents the proliferation and activity of fibroblasts in scar tissue formation, which might benefit glaucoma filtering surgery.

  12. 3D magnetic-resonance-coupling (MRC) localization of wireless capsule endoscopy

    DEFF Research Database (Denmark)

    Xia, Yongming; Zhang, Lihui; Lu, Kaiyuan

    2016-01-01

    Wireless Capsule Endoscope (WCE) enables developing actively controlled capsule for potential complex surgeries, imaging, and new medicine tests. These tasks of WCE need safe, efficient, and precise 3D localization techniques. In this paper, a new application of the magnetic resonance coupling (MRC......) technique, which has been widely developed for efficient wireless power transfer, is introduced. It is proposed that the distance dependent signal strength in a MRC system can be beneficially used for 3D localization. The new 3D-MRC localization system consists of three orthogonal emitting coils which...

  13. A study on the synthesis of multiple emulsion and multiple capsule using chitosan-PVP system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, K.T.; Shul, Y.G. [Yonsei University, Seoul (Korea, Republic of); Lee, H.; Lee, M.S.; Nam, S.I. [Cheiljaedang Co. (Korea, Republic of)

    1998-04-01

    Multiple capsule was prepared by using chitosan-PVP multiple emulsion system(W/O/W) in which oil and water phase can co-exist simultaneously. In multiple emulsion, chitosan and PVP solution were used for external and internal aqueous phase materials, respectively. And squalane was used for oil phase material. To increase the stability of multiple emulsion, multiple emulsion was ejected into the NaOH solution through the nozzle to form multiple capsule of 2-3 mm in diameter, where the chitosan-PVP composite was used as a wall materials. The hardness of this multiple capsule was found to increase as the amount of PVP increased. Antibacterial property of this multicapsule was tested by E. coli. After 1 h, there was drastic decrease of E. coli population and all the E. coli was diminished after 24 h.

  14. Effect of a controlled-release albendazole capsule on parasitism and productivity of sheep.

    Science.gov (United States)

    Corba, J; Krupicer, I; Legény, J; Juris, P; Veselý, L

    1991-11-01

    The efficacy of intraruminal albendazole (ABZ) capsules (Profitril-Captec) and the effect of treatment on productivity were studied in 300 ewes infected with gastrointestinal nematodes and the trematode Dicrocoelium dendriticum. Coprological tests revealed that treated animals remained negative for 10 weeks after the administration of capsules. Contamination of pasture with nematode larvae was significantly reduced during the whole experiment. Necropsy of 14 animals (seven treated and seven untreated) showed 96.9-99.2% efficacy against the nematodes Nematodirus spp., Oesophagostomum spp., Cooperia spp., Trichostrongylus spp. and Trichuris ovis, while efficacy was 88.5% against D. dendriticum. During the 6 month pasture season (May-October 1989), treated ewes produced on average 2.56 kg cheese and 0.6 kg wool per ewe more than untreated controls. Our study confirms the reliability of the ABZ slow-release capsules over 90 days and the positive effect of treatment on nematode contamination of pasture and ewe productivity.

  15. Study on the Pharmacokinetics and Relative Bioavailability of Irbesartan Capsul es in Heal thy Volunteers

    Institute of Scientific and Technical Information of China (English)

    顾世芬; 陈汇; 邱应海; 师少军; 曾繁典

    2002-01-01

    The pharmacokinetics and relative bioavailability were studied in 18 healthy volunteers. A single oral dose of 150 mg irbesartan capsule (test) or tablet (reference) was given to each volunteer according to a randomized 2-way crossover study. The concentrations in plasma were determined by HPLC-UV method. The main parameters of irbesartan capsules were: Cmax: 1. 502± 0. 295 μg/ml,tmax: 1. 44±0. 34 h, t1/2: 20. 21±14. 71 h, AUC0-t: 11. 087t3.443 μg/ml-1·h. The relative bioavailability of capsule to tablet was (101.4±28.9) %. The results of statistical analysis showed that two formulations were hioequivalent.

  16. Symptomatic Patency Capsule Retention in Suspected Crohn's Disease

    DEFF Research Database (Denmark)

    Rasmussen, Bjørn; Nathan, Torben; Jensen, Michael Dam

    2016-01-01

    The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two...... patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography...

  17. Capsules, toxins and AtxA as virulence factors of emerging Bacillus cereus biovar anthracis.

    Science.gov (United States)

    Brézillon, Christophe; Haustant, Michel; Dupke, Susann; Corre, Jean-Philippe; Lander, Angelika; Franz, Tatjana; Monot, Marc; Couture-Tosi, Evelyne; Jouvion, Gregory; Leendertz, Fabian H; Grunow, Roland; Mock, Michèle E; Klee, Silke R; Goossens, Pierre L

    2015-04-01

    Emerging B. cereus strains that cause anthrax-like disease have been isolated in Cameroon (CA strain) and Côte d'Ivoire (CI strain). These strains are unusual, because their genomic characterisation shows that they belong to the B. cereus species, although they harbour two plasmids, pBCXO1 and pBCXO2, that are highly similar to the pXO1 and pXO2 plasmids of B. anthracis that encode the toxins and the polyglutamate capsule respectively. The virulence factors implicated in the pathogenicity of these B. cereus bv anthracis strains remain to be characterised. We tested their virulence by cutaneous and intranasal delivery in mice and guinea pigs; they were as virulent as wild-type B. anthracis. Unlike as described for pXO2-cured B. anthracis, the CA strain cured of the pBCXO2 plasmid was still highly virulent, showing the existence of other virulence factors. Indeed, these strains concomitantly expressed a hyaluronic acid (HA) capsule and the B. anthracis polyglutamate (PDGA) capsule. The HA capsule was encoded by the hasACB operon on pBCXO1, and its expression was regulated by the global transcription regulator AtxA, which controls anthrax toxins and PDGA capsule in B. anthracis. Thus, the HA and PDGA capsules and toxins were co-regulated by AtxA. We explored the respective effect of the virulence factors on colonisation and dissemination of CA within its host by constructing bioluminescent mutants. Expression of the HA capsule by itself led to local multiplication and, during intranasal infection, to local dissemination to the adjacent brain tissue. Co-expression of either toxins or PDGA capsule with HA capsule enabled systemic dissemination, thus providing a clear evolutionary advantage. Protection against infection by B. cereus bv anthracis required the same vaccination formulation as that used against B. anthracis. Thus, these strains, at the frontier between B. anthracis and B. cereus, provide insight into how the monomorphic B. anthracis may have emerged.

  18. Erosion characteristics of an erodible tablet incorporated in a time-delayed capsule device.

    Science.gov (United States)

    McConville, Jason T; Ross, Alistair C; Florence, Alastair J; Stevens, Howard N E

    2005-01-01

    A time-delayed oral drug delivery device was investigated in which an erodible tablet (ET), sealing the mouth of an insoluble capsule, controlled the lag-time prior to drug release. The time-delayed capsule (TDC) lag-time may be altered by manipulation of the excipients used in the preparation of the ET. Erosion rates and drug release profiles from TDCs were investigated with four different excipient admixtures with lactose: calcium sulphate dihydrate (CSD), dicalcium phosphate (DCP), hydroxypropylmethyl cellulose (HPMC; Methocel K100LV grade) and silicified microcrystalline cellulose (SMCC; Prosolv 90 grade). Additionally, the compressibility of different insoluble coated capsules was tested at different moisture levels to determine their overall integrity and suitability for oral delivery. Erosion rates of CSD, DCP, and SMCC displayed a nonlinear relationship to their concentration, while HPMC indicated rapid first-order erosion followed by zero-order erosion, the onset of which was dependent on the HPMC concentration. Capsule integrity was confirmed to be most suitable for oral delivery when the insoluble ethyl cellulose coat was applied to a hard gelatin capsule using an organic spray coating process. T50% drug release times varied between 245 (+/-33.4) and 393 (+/-40.8) minutes for 8% and 20% DCP, respectively, T50% release times of 91 (+/-22.1) and 167 (+/-34.6) were observed for 8% and 20% CSD; both formulations showed incidence of premature drug release. The SMCC formulations showed high variability due to lamination effects. The HPMC formulations had T50% release times of 69 (+/-13.9), 213 (+/-25.4), and 325 (+/-30.3) minutes for 15%, 24%, and 30% HPMC concentrations respectively, with no premature drug release. In conclusion, HPMC showed the highest reproducibility for a range of time-delayed drug release from the assembled capsule formulation. The method of capsule coating was confirmed to be important by investigation of the overall capsule integrity at

  19. Capsules, toxins and AtxA as virulence factors of emerging Bacillus cereus biovar anthracis.

    Directory of Open Access Journals (Sweden)

    Christophe Brézillon

    2015-04-01

    Full Text Available Emerging B. cereus strains that cause anthrax-like disease have been isolated in Cameroon (CA strain and Côte d'Ivoire (CI strain. These strains are unusual, because their genomic characterisation shows that they belong to the B. cereus species, although they harbour two plasmids, pBCXO1 and pBCXO2, that are highly similar to the pXO1 and pXO2 plasmids of B. anthracis that encode the toxins and the polyglutamate capsule respectively. The virulence factors implicated in the pathogenicity of these B. cereus bv anthracis strains remain to be characterised. We tested their virulence by cutaneous and intranasal delivery in mice and guinea pigs; they were as virulent as wild-type B. anthracis. Unlike as described for pXO2-cured B. anthracis, the CA strain cured of the pBCXO2 plasmid was still highly virulent, showing the existence of other virulence factors. Indeed, these strains concomitantly expressed a hyaluronic acid (HA capsule and the B. anthracis polyglutamate (PDGA capsule. The HA capsule was encoded by the hasACB operon on pBCXO1, and its expression was regulated by the global transcription regulator AtxA, which controls anthrax toxins and PDGA capsule in B. anthracis. Thus, the HA and PDGA capsules and toxins were co-regulated by AtxA. We explored the respective effect of the virulence factors on colonisation and dissemination of CA within its host by constructing bioluminescent mutants. Expression of the HA capsule by itself led to local multiplication and, during intranasal infection, to local dissemination to the adjacent brain tissue. Co-expression of either toxins or PDGA capsule with HA capsule enabled systemic dissemination, thus providing a clear evolutionary advantage. Protection against infection by B. cereus bv anthracis required the same vaccination formulation as that used against B. anthracis. Thus, these strains, at the frontier between B. anthracis and B. cereus, provide insight into how the monomorphic B. anthracis may have

  20. Planar Fluorescence Imaging and Three-Dimensional Reconstructions of Capsule RCS Jets

    Science.gov (United States)

    Inman, Jennifer A.; Danehy, Paul M.; Alderfer, David W.; Buck, Gregory M.; Mccrea, Andrew C.

    2009-01-01

    Planar laser-induced fluorescence (PLIF) flowfield visualization has been used to investigate reaction control system (RCS) jet flows in the wake of hypersonic capsule reentry vehicles. Pitch, roll, and yaw RCS jets were all studied. PLIF was used to obtain off-body flow images at planar slices in these flowfields, which are not easily visualized by other techniques owing to characteristically low gas density. When viewed individually, these slices are shown to provide spatially and temporally resolved information, including the locations and characteristics of turbulent flow structures and the location of the jet flow relative to the vehicle. In addition, ensembles of slices, acquired at multiple locations throughout the flowfield, are combined using computer visualization techniques to reconstruct the three-dimensional shape of the flow. Collectively, the off-body flow visualization data set acquired in these tests represents a valuable compliment to surface measurements, especially as a basis for explaining otherwise perplexing discrepancies between such measurements and computational fluid dynamics (CFD) results. The tests described herein were conducted in the 31-Inch Mach 10 Air Tunnel at NASA Langley Research Center.

  1. Effectiveness of Qiangjijianli capsule on experimental autoimmune myasthenia gravis

    Institute of Scientific and Technical Information of China (English)

    Shunmin Li; Bo Fu; Yuyan Li; DongYang; Shudong Yang

    2006-01-01

    BACKGROUND: Experimental autoimmune myasthenia gravis(EAMG) and anti-AchR antibody of human myasthenia gravis are the same immune globulin.This antibody restricts the activity of nicotinic acetylcholine receptor and the amount of receptor binding sites is decreased,so myasthenia gravis occurs.OBJECTIVE: To observe the therapeutic effect and mechanism of action of Qiangjijianli capsule on EAMG rats.DESIGN:A randomized controlled animal experiment.SETTING: Experimental Animal Center of Guangzhou University of Traditional Chinese Medicine.MATERIALS: Acetylcholine receptors(AchR)were extracted from electric skate's electric organ which lives in the sea near Guangzhou.It had high biological activity and the protein content was 1.63 g/L.Qiangjijianli capsule (Astragalus mongholicus,Codonopsis pilosula,Atractylodes macrocephala,Angelica sinensis,Bupleurum chinense,Cairo morningglory root or leaf,Glycyrrhixa uralensis,etc.0.5 g crude drug per capsule) was bought from the Manufacturing Laboratory of Guangzhou University of Traditional Chinese Medicine with the Batch No.89-11-1.METHODS:This experiment was carried out in the Experimental Animal Center of Guangzhou University of Traditional Chinese Medicine from May to August 1990.①Adult female SD rats were immunized with AchR.The animals' movement condition was observed and recorded everyday. Ten rats were chosen as normal control group.and they were not given any treatment and raised normally.After modeled,20 successful rats were randomly assigned into 2 groups:treatmental group and model group. 2 mL Qiangjijianli capsule suspension(1 g)was intragastrically administrated into each rat of treatmental group for 30 days; The same amount of clean water was intragastrically administrated into the rats of model group for 30 days.(2)Serum AchR antibody was measured with ABC-ELISA method. After administration,the rats were sacrificed.The complete diaphragmatic muscle was extracted for in vitro receptor binding test

  2. HANARO instrumented capsule development for supporting a study on the irradiation damage of stainless steels for nuclear applications

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Y. H.; Cho, M. S.; Sohn, J. M.; Kim, H. R.; Lee, B. C.; Kim, K. H

    2000-10-01

    As a part of the program for the maximum utilization of HANARO by MOST, Korea, an instrumented capsule (00M-01U) was designed and fabricated for supporting a study on the irradiation damage of stainless steels for nuclear applications. The basic structure of the capsule for the irradiation of Stainless steels was based on that of the 99M-01K capsule irradiated successfully in HANARO. To satisfy the user requirements such as irradiation temperature and neutron fluence, the optimal arrangement of test specimens was done in the axial and circumferential direction. The temperature distribution and thermal stress of a capsule with multi-holes were obtained by a finite element analysis code, ANSYS. From these analyzed data, this capsule was found to be compatible with HANARO design requirement. Various types of specimens such as small tensile, Charpy, TEM and EPMA specimens were inserted in the capsule. The specimens will be irradiated in the IR2 test hole of HANARO at 288, 300 and 350 deg C up to a fast neutron fluence of 1.0x10{sup 20}(n/cm{sup 2})(E>1.0MeV)

  3. Plasma pharmacological study on Da Huang Zhe Chong capsule on platelet aggregation of normal person

    Institute of Scientific and Technical Information of China (English)

    WANG Dong-sheng; CHEN Fang-ping; XIAO Chang-jiang; HE Shi-lin; FU Bin; LI Xin; CAO Xing-yu; CHEN Yan; XIE Qin-zhi

    2005-01-01

    Objective To develop a plasma pharmacological method evaluates the effect of Da Huang Zhe Chong capsule on platelet aggregation and its mechanism, which is a representative Traditional Chinese Medicine Patent Prescription Promoting blood circulation by removing blood stasis. Methods Platelets specimens from healthy volunteers made serum and plasma with medicine, while platelet PRP were separated, which were divided into 8groups,i.e. auto-serum, allo-serum, serum with Da Huang Zhe Chong capsule , serum with aspirin, auto-plasma, plasma with Da Huang Zhe Chong capsule, plasma with aspirin, every group added to serum and plasma to hatch. After ADP and adrenalin were added into the specimens and hatched, the effects of specimens on platelet aggregation were observed. Results After ADP adrenalin were added, all the serum groups did not present platelet aggregation,while all the plasma group presented platelet aggregation. P1, P5, Pmax, t and TM have no significant difference (P>0. 05) between auto-plasma group and allo-plasma group induced by ADP and adrenalin. P1, P5, t and Pmax have significant differences (P<0. 01) and TM decreased significantly (P<0. 05) comparing plasma group with Da Huang Zhe Chong capsule and plasma group of aspirin to allo-plasma group. P1, t and Pmax have significant difference (P<0.05), and P5 and TM are simulate comparing plasma group with Da Huang Zhe Chong capsule to plasma group of aspirin. P1, P5, t and Pmax have significant differences (P<0. 01), P1, TM have also significant(P<0. 05), comparing plasma group of Da Huang Zhe Chong capsule with plasma of aspirin to allo-plasma group induced by adrenalin. P1 ,P5 and Pmax have significant differences (P<0.05), and t and Pmax are simulate comparing plasma group with Da Huang Zhe Chong capsule with plasma group of aspirin. Conclusion The serum pharmacological study is inappropriate to study platelet aggregation in vitro. The plasma pharmacological study is inappropriate to study

  4. An Investigation Into Bayesian Networks for Modeling National Ignition Facility Capsule Implosions

    Energy Technology Data Exchange (ETDEWEB)

    Mitrani, J

    2008-08-18

    Bayesian networks (BN) are an excellent tool for modeling uncertainties in systems with several interdependent variables. A BN is a directed acyclic graph, and consists of a structure, or the set of directional links between variables that depend on other variables, and conditional probabilities (CP) for each variable. In this project, we apply BN's to understand uncertainties in NIF ignition experiments. One can represent various physical properties of National Ignition Facility (NIF) capsule implosions as variables in a BN. A dataset containing simulations of NIF capsule implosions was provided. The dataset was generated from a radiation hydrodynamics code, and it contained 120 simulations of 16 variables. Relevant knowledge about the physics of NIF capsule implosions and greedy search algorithms were used to search for hypothetical structures for a BN. Our preliminary results found 6 links between variables in the dataset. However, we thought there should have been more links between the dataset variables based on the physics of NIF capsule implosions. Important reasons for the paucity of links are the relatively small size of the dataset, and the sampling of the values for dataset variables. Another factor that might have caused the paucity of links is the fact that in the dataset, 20% of the simulations represented successful fusion, and 80% didn't, (simulations of unsuccessful fusion are useful for measuring certain diagnostics) which skewed the distributions of several variables, and possibly reduced the number of links. Nevertheless, by illustrating the interdependencies and conditional probabilities of several parameters and diagnostics, an accurate and complete BN built from an appropriate simulation set would provide uncertainty quantification for NIF capsule implosions.

  5. Computational modeling as part of alternative testing strategies in the respiratory and cardiovascular systems: inhaled nanoparticle dose modeling based on representative aerosol measurements and corresponding toxicological analysis.

    Science.gov (United States)

    Pilou, Marika; Mavrofrydi, Olga; Housiadas, Christos; Eleftheriadis, Kostas; Papazafiri, Panagiota

    2015-05-01

    The objectives of modeling in this work were (a) the integration of two existing numerical models in order to connect external exposure to nanoparticles (NPs) with internal dose through inhalation, and (b) to use computational fluid-particle dynamics (CFPD) to analyze the behavior of NPs in the respiratory and the cardiovascular system. Regarding the first objective, a lung transport and deposition model was combined with a lung clearance/retention model to estimate NPs dose in the different regions of the human respiratory tract and some adjacent tissues. On the other hand, CFPD was used to estimate particle transport and deposition of particles in a physiologically based bifurcation created by the third and fourth lung generations (respiratory system), as well as to predict the fate of super-paramagnetic particles suspended in a liquid under the influence of an external magnetic field (cardiovascular system). All the above studies showed that, with proper refinement, the developed computational models and methodologies may serve as an alternative testing strategy, replacing transport/deposition experiments that are expensive both in time and resources and contribute to risk assessment.

  6. Characterization and identification of suspected counterfeit miltefosine capsules.

    Science.gov (United States)

    Dorlo, Thomas P C; Eggelte, Teunis A; de Vries, Peter J; Beijnen, Jos H

    2012-03-07

    Recently, it was revealed that generic miltefosine capsules for the treatment of visceral leishmaniasis, a fatal parasitic disease, were possibly counterfeit products. Here we report on the methods to characterize and identify miltefosine in pharmaceutical products and the procedures that were used to assess the quality of these suspected counterfeit products. Characterization and identification of miltefosine were done with liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), Fourier transform infrared (FT-IR) spectroscopy and near-infrared (NIR) spectroscopy. Moreover, a simple, rapid and inexpensive colorimetric test was developed and evaluated for the detection of miltefosine in pharmaceutical products that can be used in the field. The complementary analytical techniques presented here were able to determine qualitatively or (semi-)quantitatively the presence or absence of miltefosine in pharmaceutical preparations and could identify suspected counterfeit miltefosine capsules. This finding of a suspected counterfeit drug intended to treat a neglected disease in a resource-poor country emphasizes the urgent need to develop more simple inexpensive assays to evaluate drug quality for use in the field.

  7. On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy

    Science.gov (United States)

    Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.

    2011-03-01

    Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.

  8. Characterization of novel lactoferrin loaded capsules prepared with polyelectrolyte complexes.

    Science.gov (United States)

    Wu, Qing-Xi; Zhang, Qi-Lei; Lin, Dong-Qiang; Yao, Shan-Jing

    2013-10-15

    Novel capsules loaded with lactoferrin (LF) were prepared using polyelectrolyte complexes that were formed by water soluble chitosan (WSC), sodium cellulose sulfate (NaCS) and sodium polyphosphate (PPS). Normal chitosan (soluble in acidic conditions) was chosen as a control to prepare similar capsules with NaCS and PPS. (1)H NMR and FTIR spectra analysis showed that WSC was in a form of chitosan hydrochloride which can be directly dissolved and protonated in acid-free water. SEM results showed that the capsules had a typical wall-capsule structure with a regular spherical shape and an average diameter of 1.97 mm. TGA studies revealed that the thermal stability of the capsules were enhanced and the moisture content of the drug-free/loaded capsules were 6.3% and 3.2%. SDS-PAGE results showed that the primary structures of the processed LF in the capsules were unchanged. Drug loading (LE%) and encapsulation efficiency (EE%) analysis showed that the capsules had a higher LE% (45.6%) and EE% (70.7%) than that of the control. In vitro release studies showed that the capsules had a regular and sustainable release profiles in simulated colonic fluid. All of these results indicated that the capsules prepared could be used as a candidate protein drug carrier for colon. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Basic ammonothermal GaN growth in molybdenum capsules

    Science.gov (United States)

    Pimputkar, S.; Speck, J. S.; Nakamura, S.

    2016-12-01

    Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).

  10. Childhood Vitamin A Capsule Supplementation Coverage in Nigeria: A Multilevel Analysis of Geographic and Socioeconomic Inequities

    OpenAIRE

    Olatunde Aremu; Stephen Lawoko; Koustuv Dalal

    2010-01-01

    Vitamin A deficiency (VAD) is a huge public health burden among preschool-aged children in sub-Saharan Africa, and is associated with a high level of susceptibility to infectious diseases and pediatric blindness. We examined the Nigerian national vitamin A capsule (VAC) supplementation program, a short-term cost-effective intervention for prevention of VAD-associated morbidity for equity in terms of socioeconomic and geographic coverage. Using the most current, nationally representative data ...

  11. Profile of collagen gene expression in the glenohumeral capsule of patients with traumatic anterior instability of the shoulder,

    Directory of Open Access Journals (Sweden)

    Paulo Santoro Belangero

    2014-12-01

    Full Text Available Objective:To evaluate the expression of the genes COL1A1, COL1A2, COL3A1 and COL5A1 in the glenohumeral capsule of patients with traumatic anterior instability of the shoulder.Methods:Samples from the glenohumeral capsule of 18 patients with traumatic anterior instability of the shoulder were evaluated. Male patients with a positive grip test and a Bankart lesion seen on magnetic resonance imaging were included. All the patients had suffered more than one episode of shoulder dislocation. Samples were collected from the injured glenohumeral capsule (anteroinferior region and from the macroscopically unaffected region (anterosuperior region of each patient. The expression of collagen genes was evaluated using the polymerase chain reaction after reverse transcription with quantitative analysis (qRT-PCR.Results:The expression of COL1A1, COL1A2 and COL3A1 did not differ between the two regions of the shoulder capsule. However, it was observed that the expression of COL5A1 was significantly lower in the anteroinferior region than in the anterosuperior region (median ± interquartile range: 0.057 ±0.052 vs. 0.155 ±0.398; p = 0.028 of the glenohumeral capsule.Conclusion:The affected region of the glenohumeral capsule in patients with shoulder instability presented reduced expression of COL5A1.

  12. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  13. Simulation and evaluation of rupturable coated capsules by finite element method.

    Science.gov (United States)

    Yang, Yan; Fang, Jie; Shen, Lian; Shan, Weiguang

    2017-03-15

    The objective of this study was to simulate and evaluate the burst behavior of rupturable coated capsules by finite element method (FEM). Film and coated capsules were prepared by dip-coating method and their dimensions were determined by stereomicroscope. Mechanical properties of the film were measured by tensile test and used as material properties of FEM models. Swelling pressure was determined by restrained expansion method and applied to the internal surface of FEM models. Water uptake of coated capsules was determined to study the formation of internal pressure. Burst test and in vitro dissolution was used to verify the FEM models, which were used to study and predict the coating burst behavior. Simulated results of coating burst behavior were well agreed with the experiment results. Swelling pressure, material properties and dimensions of coating had influence on the maximum stress. Burst pressure and critical L-HPC content were calculated for burst prediction and formulation optimization. FEM simulation was a feasible way to simulate and evaluate the burst behavior of coated capsules. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Capsule formation and asymbiotic seed germination in some hybrids of Phalaenopsis, influenced by pollination season and capsule maturity.

    Science.gov (United States)

    Balilashaki, Khosro; Gantait, Saikat; Naderi, Roohangiz; Vahedi, Maryam

    2015-07-01

    We explored the influence of pollination season and maturity of capsule on post-pollination capsule formation and in vitro asymbiotic seed germination, respectively. Three Phalaenopsis orchid hybrids, namely, 'Athens', 'Moscow' and 'Lusaka' flowers were artificially self-pollinated during winter, spring, summer and fall seasons and the impact of the pollination seasons was evident during capsule formation. It was observed that winter was the most suitable season for pollination of all the three Phalanaeopsis hybrids resulting in 80-88 % capsule formation. During summer, the pollination success rate was 24-28 %, but resulted in successful capsule formation. Season of pollination further delimited the germination efficiency of seeds harvested from capsules of variable maturity levels. Invariably, seeds collected from winter-pollinated capsules performed best in germination compared to other seasons, for instance, 'Moscow' seeds took less than 14 days to germinate from capsules developed following winter-pollination. Regarding the influence of capsule maturity on seed germination, we observed that seeds derived from 5-month mature capsules, invariably took least time to germinate than that of the 3-month or 7-month in all three hybrids, e.g., for 'Moscow' it was 13.9 days with a maximum of 90.3 % germination.

  15. Fetal myocardium in the kidney capsule: an in vivo model of repopulation of myocytes by bone marrow cells.

    Directory of Open Access Journals (Sweden)

    Eric Y Zhang

    Full Text Available Debate surrounds the question of whether the heart is a post-mitotic organ in part due to the lack of an in vivo model in which myocytes are able to actively regenerate. The current study describes the first such mouse model--a fetal myocardial environment grafted into the adult kidney capsule. Here it is used to test whether cells descended from bone marrow can regenerate cardiac myocytes. One week after receiving the fetal heart grafts, recipients were lethally irradiated and transplanted with marrow from green fluorescent protein (GFP-expressing C57Bl/6J (B6 donors using normal B6 recipients and fetal donors. Levels of myocyte regeneration from GFP marrow within both fetal myocardium and adult hearts of recipients were evaluated histologically. Fetal myocardium transplants had rich neovascularization and beat regularly after 2 weeks, continuing at checkpoints of 1, 2, 4, 6, 8 and12 months after transplantation. At each time point, GFP-expressing rod-shaped myocytes were found in the fetal myocardium, but only a few were found in the adult hearts. The average count of repopulated myocardium with green rod-shaped myocytes was 996.8 cells per gram of fetal myocardial tissue, and 28.7 cells per adult heart tissue, representing a thirty-five fold increase in fetal myocardium compared to the adult heart at 12 months (when numbers of green rod-shaped myocytes were normalized to per gram of myocardial tissue. Thus, bone marrow cells can differentiate to myocytes in the fetal myocardial environment. The novel in vivo model of fetal myocardium in the kidney capsule appears to be valuable for testing repopulating abilities of potential cardiac progenitors.

  16. Comprehensive and Systematic Analysis of the Immunocompatibility of Polyelectrolyte Capsules.

    Science.gov (United States)

    Zyuzin, Mikhail V; Díez, Paula; Goldsmith, Meir; Carregal-Romero, Susana; Teodosio, Cristina; Rejman, Joanna; Feliu, Neus; Escudero, Alberto; Almendral, María Jesús; Linne, Uwe; Peer, Dan; Fuentes, Manuel; Parak, Wolfgang J

    2017-02-15

    The immunocompability of polyelectrolyte capsules synthesized by layer-by-layer deposition has been investigated. Capsules of different architecture and composed of either non-degradable or biodegradable polymers, with either positively or negatively charged outer surface, and with micrometer size, have been used, and the capsule uptake by different cell lines has been studied and quantified. Immunocompatibility studies were performed with peripheral blood mononuclear cells (PBMCs). Data demonstrate that incubation with capsules, at concentrations relevant for practical applications, did not result in a reduced viability of cells, as it did not show an increased apoptosis. Presence of capsules also did not result in an increased expression of TNF-α, as detected with antibody staining, as well as at mRNA level. It also did not result in increased expression of IL-6, as detected at mRNA level. These results indicate that the polyelectrolyte capsules used in this study are immunocompatible.

  17. The motion of a deforming capsule through a corner

    CERN Document Server

    Zhu, Lailai

    2014-01-01

    A three-dimensional deformable capsule convected through a channel/duct with a corner is studied via numerical simulations using an accelerated boundary integral method adapted to general geometries. A global spectral method is adopted to resolve the dynamics of the capsule's membrane developing elastic tensions according to the Neo-Hookean constitutive law and bending moments in an inertialess flow. The simulations show that the trajectory of the capsule closely follows the underlying streamlines and the deformation of the capsule induces an anti-clockwise rotation of its material points with respect to the travelling direction. The surface area, principle tension and elastic energy of the capsule increase around the corner. Their temporal evolutions are characterised by a clear phase delay and the loss of time-reversal symmetry of Stokes flow due to the elasticity of membrane. The capsule centroid velocity decreases approaching the corner as the mean flow does while a velocity overshoot is observed past the...

  18. Analysis Of Wetted-Foam ICF Capsule Perormance

    Science.gov (United States)

    Peterson, R.; Olson, R.; Zylstra, A.; Haines, B.; Yi, A.; Bradley, P.; Yin, L.; Leeper, R.; Kline, J.

    2016-10-01

    The performance of wetted-foam ICF capsules is investigated with the RAGE Eulerian radiation-hydrodynamics computer code. We are developing an experimental platform on NIF that employs a wetted foam liquid DT fuel layer ICF capsules. By varying the capsule temperature, the vapor density in the capsule can be prescribed, and the hot spot convergence ratio (CR) of the capsule implosion can be controlled. This allows us to investigate the fidelity of RAGE in modeling of capsule implosions as the value of CR is varied. In the NIF experiments, CR can be varied from 12 to 25. This presentation will cover simulations with RAGE of three NIF shots performed in 2016; a DD and a DT liquid fuel shot with CR =14 and a DT shot with CR =16. It will also discuss analysis of future experiments. This work was performed under auspices of the U. S. DOE by LANL.

  19. Role of shocks and mix caused by capsule defects

    Science.gov (United States)

    Bradley, P. A.; Cobble, J. A.; Tregillis, I. L.; Schmitt, M. J.; Obrey, K. D.; Glebov, V.; Batha, S. H.; Magelssen, G. R.; Fincke, J. R.; Hsu, S. C.; Krasheninnikova, N. S.; Murphy, T. J.; Wysocki, F. J.

    2012-09-01

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The "perfect" capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  20. Gelatin and Non-Gelatin Capsule Dosage Forms.

    Science.gov (United States)

    Gullapalli, Rampurna P; Mazzitelli, Carolyn L

    2017-06-01

    Capsules offer an alternate to tablets for oral delivery of therapeutic compounds. One advantage of capsules over tablets is their amenability to deliver not only solids but also nonaqueous liquids and semisolids as a unit dose solid dosage form. Shell component is an essential part of capsule dosage forms. Capsule shells, available as hard or soft shells, are formulated from gelatin or a non-gelatin polymeric material such as hypromellose and starch, water, and with or without a nonvolatile plasticizer. The capsule shells may also be formulated to modify the release of their fill contents in a site-specific manner in the gastrointestinal tract. The goal of the current review is to provide an in-depth discussion on polymeric film-forming materials and manufacturing technologies used in the production of capsule shells. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  1. Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.

    Science.gov (United States)

    Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar

    2013-08-27

    Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to

  2. Analysis of Wireless Capsule Endoscopy Images using Local Binary Patterns

    Directory of Open Access Journals (Sweden)

    Adriana Florentina CONSTANTINESCU

    2015-06-01

    Full Text Available Wireless capsule endoscopy, the gold standard in the screening and diagnosis of small bowel diseases, is one of the most recent investigations for gastrointestinal pathology. This examination has the advantages of being non-invasive, painless, with a large clinical yield, especially for small bowel diseases, but also some disadvantages. The long time necessary for reading and interpreting all frames acquired is one of these disadvantages. This inconvenient could be improved through different methods by using software applications. In this study we have used a software application for texture analysis based on local binary pattern (LBP operator. This operator detects and removes non-informative frames in a first step, then identifies potential lesions. Our study group consisted of 33 patients from the Gastroenterology and Hepatology Centre Craiova and from the 1st Internal Medicine and Gastroenterology Clinic from the Emergency County Hospital of Craiova. The patients included in the study have corresponded to our inclusion criteria established. The exclusion criteria were represented by the contraindications of the capsule endoscopy. In the first phase of the study, we have removed the non-informative frames from the original videos obtained, and we have acquired an average reduction of 6.96% from the total number of images. In the second phase, using the same LBP operator, we have correctly identified 93.16% of telangiectasia lesions. Our study demonstrated that software applications based on LBP operator can lead to a shorter analysis time, by reducing the overall frames number, and can also provide support in diagnosis.

  3. 21 CFR 520.1921 - Prochlorperazine, isopropamide, with neomycin sustained-release capsules.

    Science.gov (United States)

    2010-04-01

    ... sustained-release capsules. 520.1921 Section 520.1921 Food and Drugs FOOD AND DRUG ADMINISTRATION... capsules. (a) Specifications. Each capsule contains either: (1) Capsule No. 1: 3.33 milligrams of... base (as the sulfate); or (2) Capsule No. 3: 10 milligrams of prochlorperazine (as the dimaleate), 5...

  4. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...... occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that capsule polysaccharides sterically prevent receptor-target recognition of short bacterial adhesins...

  5. Small intestinal model for electrically propelled capsule endoscopy

    Directory of Open Access Journals (Sweden)

    Woo Sang Hyo

    2011-12-01

    Full Text Available Abstract The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule.

  6. Portable wireless power transmission system for video capsule endoscopy.

    Science.gov (United States)

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  7. A portable wireless power transmission system for video capsule endoscopes.

    Science.gov (United States)

    Shi, Yu; Yan, Guozheng; Zhu, Bingquan; Liu, Gang

    2015-01-01

    Wireless power transmission (WPT) technology can solve the energy shortage problem of the video capsule endoscope (VCE) powered by button batteries, but the fixed platform limited its clinical application. This paper presents a portable WPT system for VCE. Besides portability, power transfer efficiency and stability are considered as the main indexes of optimization design of the system, which consists of the transmitting coil structure, portable control box, operating frequency, magnetic core and winding of receiving coil. Upon the above principles, the correlation parameters are measured, compared and chosen. Finally, through experiments on the platform, the methods are tested and evaluated. In the gastrointestinal tract of small pig, the VCE is supplied with sufficient energy by the WPT system, and the energy conversion efficiency is 2.8%. The video obtained is clear with a resolution of 320×240 and a frame rate of 30 frames per second. The experiments verify the feasibility of design scheme, and further improvement direction is discussed.

  8. Status Report on Irradiation Capsules Designed to Evaluate FeCrAl-UO2 Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Howard, Richard H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-06-24

    This status report provides the background and current status of a series of irradiation capsules that were designed and are being built to test the interactions between candidate FeCrAl cladding for enhanced accident tolerant applications and prototypical enriched commercial UO2 fuel in a neutron radiation environment. These capsules will test the degree, if any, of fuel cladding chemical interactions (FCCI) between FeCrAl and UO2. The capsules are to be irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory to burn-ups of 10, 30, and 50 GWd/MT with a nominal target temperature at the interfaces between the pellets and clad of 350°C.

  9. Campylobacter polysaccharide capsules: virulence and vaccines

    Directory of Open Access Journals (Sweden)

    Patricia eGuerry

    2012-02-01

    Full Text Available Campylobacter jejuni remains a major cause of bacterial diarrhea worldwide and is associated with numerous sequelae, including Guillain Barre Syndrome, inflammatory bowel disease, reactive arthritis, and irritable bowel syndrome. C. jejuni is unusual for an intestinal pathogen in its ability to coat its surface with a polysaccharide capsule (CPS. These capsular polysaccharides vary in sugar composition and linkage, especially those involving heptoses of unusual configuration and O-methyl phosphoramidate linkages. This structural diversity is consistent with CPS being the major serodeterminant of the Penner scheme, of which there are 47 C. jejuni serotypes. Both CPS expression and expression of modifications are subject to phase variation by slip strand mismatch repair. Although capsules are virulence factors for other pathogens, the role of CPS in C. jejuni disease has not been well defined beyond descriptive studies demonstrating a role in serum resistance and for diarrhea in a ferret model of disease. However, perhaps the most compelling evidence for a role in pathogenesis are data that CPS conjugate vaccines protect against diarrheal disease in non-human primates. A CPS conjugate vaccine approach against this pathogen is intriguing, but several questions need to be addressed, including the valency of CPS types required for an effective vaccine. There have been numerous studies of prevalence of CPS serotypes in the developed world, but few studies from developing countries where the disease incidence is higher. The complexity and cost of Penner serotyping has limited its usefulness, and a recently developed multiplex PCR method for determination of capsule type offers the potential of a more rapid and affordable method. Comparative studies have shown a strong correlation of the two methods and studies are beginning to ascertain CPS-type distribution worldwide, as well as examination of correlation of severity of illness with specific CPS types.

  10. Study on the Effects of Liquid Thermal Media on the Irradiation Capsule of High-Temperature Materials

    Directory of Open Access Journals (Sweden)

    Man Soon Cho

    2015-01-01

    Full Text Available Irradiation tests of materials at HANARO have usually been conducted using a standard capsule at temperatures of about 300°C for irradiation of materials used at PWR. Thus, the standard capsule uses aluminum as the specimen holder, which acts to dissipate the thermal energy. Future nuclear systems such as a VHTR and SFR require the irradiation tests at a relatively high temperature. As an alternative to aluminum which has been used as the thermal media in a standard material capsule, the characteristics of liquid metals such as NaK and LBE are reviewed. The temperatures of the capsule are affected by the variation of parameters such as the gap and wall thickness of the container. In particular, the external gap is most important in determining the temperature of the specimen. LBE raises the temperature of the specimen higher than NaK at the same configuration of the capsule. Thus, LBE can lessen the gap of the parts and reduce the vibration for a stable long-term test in reactor.

  11. Periprosthetic breast capsules and immunophenotypes of inflammatory cells.

    Science.gov (United States)

    Meza Britez, Maria Elsa; Caballero Llano, Carmelo; Chaux, Alcides

    2012-09-01

    BACKGROUND: Silicone gel-containing breast implants have been widely used for aesthetic and reconstructive mammoplasty. The development of a periprosthetic capsule is considered a local reparative process against the breast implant in which a variety of inflammatory cells may appear. Nevertheless, only few reports have evaluated the immunophenotypes of those inflammatory cells. Herein, we aim to provide more information in this regard evaluating 40 patients with breast implants. METHODS: We studied the immunophenotype of the inflammatory cells of capsular implants using antibodies against lymphocytes (CD3, CD4, CD8, CD20, CD45, and CD30) and histiocytes (CD68). Percentages of CD3 and CD20 positive cells were compared using the unpaired Student's t test. Fisher's test was also used to compare Baker grades by implant type, implant profile, and location and the presence of inflammatory cells by implant type. RESULTS: The associations between Baker grades and implant type and location were statistically nonsignificant (p = 0.42 in both cases). However, the use of low profile implants was significantly associated (p = 0.002) with a higher proportion of Baker grades 3 and 4. We found evidence of inflammation in 92.5 % of all implant capsules, with a statistically significant (p = 0.036) higher proportion in textured breast implants. T cells predominated over B cells. Textured implants elicited a more marked response to T cells than smooth implants, with a similar proportion of helper and cytotoxic T cells. Textured implants showed statistically significant higher percentages of CD3 positive cells than smooth implants. Percentages of CD20 positive cells were similar in textured and smooth implants. CONCLUSIONS: These results suggest that textured breast implants might induce a stronger local T cell immune response. Our findings could shed some light to understand the association of silicone breast implants and some cases of anaplastic large cell lymphomas

  12. List of Accredited Representatives

    Data.gov (United States)

    Department of Veterans Affairs — VA accreditation is for the sole purpose of providing representation services to claimants before VA and does not imply that a representative is qualified to provide...

  13. The representative animal

    OpenAIRE

    Harrison, J M

    1994-01-01

    The anthropocentric approach to the study of animal behavior uses representative nonhuman animals to understand human behavior. This approach raises problems concerning the comparison of the behavior of two different species. The datum of behavior analysis is the behavior of humans and representative animal phenotypes. The behavioral phenotype is the product of the ontogeny and phylogeny of each species, and this requires that contributions of genotype as well as behavioral history to experim...

  14. Do the Kaufman tests of cognitive ability and academic achievement display construct bias across a representative sample of Black, Hispanic, and Caucasian school-age children in grades 1 through 12?

    Science.gov (United States)

    Scheiber, Caroline

    2016-08-01

    As the demographic profile in the United States continues to change and becomes ethnically more diverse, the need for culturally appropriate test instruments has become a national concern among educators, clinicians, and researchers. The Kaufman Assessment Battery for Children-2nd Edition (KABC-II) and the Kaufman Test of Educational Achievement-2nd Edition (KTEA-II) are 2 popular tests of intelligence and achievement, known to appeal to an ethnically diverse client population. The present study investigated test bias in terms of the test scores' construct validity across a nationally representative sample of Caucasian, Black, and Hispanic (N = 2,001) children in Grades 1-12. Confirmatory factor analysis was used to assess whether increasing sets of equality constraints fit the test scores' underlying theoretical model equally well for all 3 ethnic groups. Results showed that factorial invariance of the factor structure, based on 7 Cattell-Horn-Carroll (CHC) model broad abilities, was met for all 3 groups. Outcomes contribute to a scarce body of literature on ethnic test bias that goes beyond the simple comparison of mean score differences. Results of this study provide the evidence needed to justify continuous use of the KABC-II and KTEA-II in the assessment of minority group children and adolescents. Furthermore, findings are generalizable beyond the Kaufman tests to other popular tests of intelligence and achievement; this is because this study is based on the CHC factor structure, a universal theory of cognition that is used as the theoretical underpinning by many well-known tests of intelligence and achievement, including the most recent versions of the Wechsler scales. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  15. Formulation and stability evaluation of extemporaneously prepared atenolol capsules from crushed atenolol tablets.

    Science.gov (United States)

    Zaid, Abdel Naser; Malkieh, Numan; Kharoaf, Maher; Abu Ghoush, Abeer; Al-Ramahi, Rowa'

    2012-01-01

    The purpose of this study was to formulate a 25-mg atenolol capsule starting from a commercial 100-mg atenolol tablet, given the fact that this strength is not available in Palestine and also because 50-mg atenolol tablets failed the splitting uniformity test of the European Pharmacopoeia, and to evaluate the chemical stability and dissolution behavior of the obtained capsules so as to ensure a high-quality product. A high-performance liquid chromatographic system was used for the analysis and quantification of atenolol in the samples studied. Samples of atenoIol for analysis were prepared as reported by the United States Pharmacopeia monograph. Disintegration and dissolution tests were performed according to the United States Pharmacopeia. The high-performance liquid chromatography assay indicated that the 25-mg atenolol capsules were stable for four months when stored at ambient temperature conditions. The disintegration time for all atenolol capsules was within the United States Pharmacopeia limits of 15 minutes. Atenolol release profile showed that approximately 90% of atenolol dissolved after 10 minutes. This study is important for patients who need to take one half of a 50-mg tablet, but for whom the splitting process doesn't give equal halves, and also for modifying the dose for patients with renal or hepatic problems. Therefore, it is possible for the community pharmacist to crush atenolol 100-mg tablets and refill them in new capsules with each containing a precise amount of atenolol, calculated according to body surface area and kidney and liver functions without affecting the chemical stability of the active ingredient nor its dissolution profile and also have a cost effective dosage form.

  16. Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract.

    Science.gov (United States)

    Liu, Gang; Yan, Guozheng; Zhu, Bingquan; Lu, Li

    2016-11-01

    In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.

  17. [Advance directives. Representatives' opinions].

    Science.gov (United States)

    Busquets I Font, J M; Hernando Robles, P; Font I Canals, R; Diestre Ortin, G; Quintana, S

    The use and usefulness of Advance Directives has led to a lot of controversy about their validity and effectiveness. Those areas are unexplored in our country from the perspective of representatives. To determine the opinion of the representatives appointed in a registered Statement of Advance Directives (SAD) on the use of this document. Telephone survey of representatives of 146 already dead people and who, since February 2012, had registered a SAD document. More the two-thirds (98) of respondents recalled that the SAD was consulted, with 86 (58.9%) saying that their opinion as representative was consulted, and 120 (82.1%) believe that the patient's will was respected. Of those interviewed, 102 (69.9%) believe that patients who had previously planned their care using a SAD had a good death, with 33 (22.4%) saying it could have been better, and 10 (6.9%) believe they suffered greatly. The SAD were mostly respected and consulted, and possibly this is related to the fact that most of the representatives declare that the death of those they represented was perceived as comfortable. It would be desirable to conduct further studies addressed at health personnel in order to know their perceptions regarding the use of Advance Directives in the process of dying. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Study on a magnetic spiral-type wireless capsule endoscope controlled by rotational external permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Bo, E-mail: yebo@hubu.edu.cn [School of Mechanical Science & Engineering, Huazhong University of Science & Technology, Wuhan 430074 (China); School of Computer Science and Information Engineering, HuBei University, Wuhan 430062 (China); Zhang, Wei [Department of Mechanical Engineering, Hubei University of Automotive Technology, Shiyan 442002 (China); Sun, Zhen-jun [School of Mechanical Science & Engineering, Huazhong University of Science & Technology, Wuhan 430074 (China); Guo, Lin [School of Computer Science and Information Engineering, HuBei University, Wuhan 430062 (China); Deng, Chao [School of Mechanical Science & Engineering, Huazhong University of Science & Technology, Wuhan 430074 (China); Chen, Ya-qi [Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030 (China); Zhang, Hong-hai [School of Mechanical Science & Engineering, Huazhong University of Science & Technology, Wuhan 430074 (China); Liu, Sheng [School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072 (China)

    2015-12-01

    In this paper, the authors propose rotating an external permanent magnet (EPM) to manipulate the synchronous rotation of a magnetic spiral-type wireless capsule endoscope (WCE), and the synchronous rotation of the WCE is converted to its translational motion in intestinal tract. In order to preliminarily verify the feasibility of this method, a handheld actuator (HA) controlled by micro controller unit, a magnetic spiral-type WCE and a bracket were fabricated, theoretical analysis and simulations about the control distance of this method were performed, and in ex-vivo tests were examined in porcine small intestine to verify the control distance and control performances of this method. It was demonstrated that this method showed good performances in controlling the translational motion of the magnetic spiral-type WCE, and this method has great potential to be used in clinical application. - Highlights: • A new magnetic control method for spiral-type wireless capsule endoscope is proposed. • Wireless capsule endoscope rotates synchronously with external permanent magnet. • The method controls the wireless capsule endoscope well in porcine small intestine. • Long control distance makes the method may be used in future medical application. • Experimental setup has great advantages: high cost performance and easy operation.

  19. Thickening of the inferior glenohumeral capsule: an ultrasound sign for shoulder capsular contracture.

    Science.gov (United States)

    Michelin, Paul; Delarue, Yohann; Duparc, Fabrice; Dacher, Jean Nicolas

    2013-10-01

    The aim of this retrospective study was to measure the inferior glenohumeral capsule thickness of shoulders clinically affected by capsular contracture by comparison to the contralateral asymptomatic side. Bilateral shoulder ultrasound (US) examinations of 20 patients with clinically or MRI proven unilateral capsular contracture were retrospectively assessed. Inferior capsule evaluation was performed with a transducer placed within the axilla in maximally abducted shoulders. Measurements were symmetrically performed orthogonally to the inferior glenohumeral ligament (IGHL) in the axial plane; the coronal plane was used to ensure the tension of the IGHL. The significance of any difference in thickening was assessed with the Mann-Whitney test. The average thickness was 4.0 mm in shoulders with capsular contracture vs. 1.3 mm in asymptomatic contralateral shoulders (P contracture and inferior capsule thickness increase showed US features of other painful diseases of the rotator cuff. The thickness of the inferior capsule is measurable through ultrasound examination and appears to be increased in shoulders with capsular contracture. Exploration of the inferior aspect of the shoulder joint could be added to shoulder US examination protocols for capsular contracture assessment even if other rotator cuff abnormalities are diagnosed by US. • Ultrasound is increasingly used to diagnose shoulder problems. • The thickness of the inferior glenohumeral ligament is measurable in the axilla. • The inferior glenohumeral ligament appears thickened in shoulders with capsular contracture. • Capsular contracture ultrasound features can be associated with other rotator cuff problems.

  20. Developing hydroxypropyl methylcellulose/hydroxypropyl starch blends for use as capsule materials.

    Science.gov (United States)

    Zhang, Liang; Wang, Yanfei; Liu, Hongsheng; Yu, Long; Liu, Xingxun; Chen, Ling; Zhang, Nouzi

    2013-10-15

    Blends of hydroxypropyl methylcellulose (HPMC) with up to 70% hydroxypropyl starch (HPS) were developed for use as hard capsule materials. Polyethylene glycol (PEG) was used as both a plasticizer and a compatibilizer in the blends. In order to prepare hard capsules for pharmaceutical application using the well-established method of dipping stainless steel mold pins into solution then drying at certain temperature, equilibrated solutions with higher solids concentration (20%) were investigated and developed. The solutions, films and capsules of the different HPMC/HPS blends were characterized by viscosity, transparency, tensile testing, water contact angle, SEM, as well as FTIR. The results showed that the blend system is immiscible but compatible in certain degree, especially after adding PEG. The hydroxypropylene groups grafted onto both cellulose and starch improved the compatibility between the HPMC and the modified starch. The higher viscosity of starch at lower temperature improved the viscosity balance of the system, which enlarged the operation window for the dipping-drying technique. The PEG increased the transparency and toughness of the various blends. By optimizing temperature and incubation time to control viscosity, capsules of various blends were successfully developed.

  1. Effects of alga polysaccharide capsule shells on in-vivo bioavailability and disintegration

    Institute of Scientific and Technical Information of China (English)

    LI Ting; GUO Shuju; MA Lin; YUAN Yi; HAN Lijun

    2012-01-01

    Gelatin has been used in hard capsule shells for more than a century,and some shortcomings have appeared,such as high moisture content and risk of transmitting diseases of animal origin to people.Based on available studies regarding gelatin and vegetable shells,we developed a new type of algal polysaccharide capsule (APPC) shells.To test whether our products can replace commercial gelatin shells,we measured in-vivo plasma concentration of 12 selected volunteers with a model drug,ibuprofen,using high performance liquid chromatography (HPLC),by calculating the relative bioavailability of APPC and Qualicaps(R) referenced to gelatin capsules and assessing bioequivalence of the three types of shells,and calculated pharmacokinetic parameters with the software DAS 2.0 (China).The results show that APPC shells possess bioequivalence with Qualicaps(R) and gelatin shells.Moreover,the disintegration behavior of four types of shells (APPC,Vegcaps(R),Qualicaps(R) and gelatin shells) with the content of lactose and radioactive element (99mTc) was observed via gamma-scintigraphic images.The bioavailability and gamma-scintigraphic studies showed that APPC was not statistically different from other vegetable and gelatin capsule shells with respect to in-vivo behavior.Hence,it can be concluded that APPCs are exchangeable with other vegetable and gelatin shells.

  2. Effects of alga polysaccharide capsule shells on in-vivo bioavailability and disintegration

    Science.gov (United States)

    Li, Ting; Guo, Shuju; Ma, Lin; Yuan, Yi; Han, Lijun

    2012-01-01

    Gelatin has been used in hard capsule shells for more than a century, and some shortcomings have appeared, such as high moisture content and risk of transmitting diseases of animal origin to people. Based on available studies regarding gelatin and vegetable shells, we developed a new type of algal polysaccharide capsule (APPC) shells. To test whether our products can replace commercial gelatin shells, we measured in-vivo plasma concentration of 12 selected volunteers with a model drug, ibuprofen, using high performance liquid chromatography (HPLC), by calculating the relative bioavailability of APPC and Qualicaps® referenced to gelatin capsules and assessing bioequivalence of the three types of shells, and calculated pharmacokinetic parameters with the software DAS 2.0 (China). The results show that APPC shells possess bioequivalence with Qualicaps® and gelatin shells. Moreover, the disintegration behavior of four types of shells (APPC, Vegcaps®, Qualicaps® and gelatin shells) with the content of lactose and radioactive element (99mTc) was observed via gamma-scintigraphic images. The bioavailability and gamma-scintigraphic studies showed that APPC was not statistically different from other vegetable and gelatin capsule shells with respect to in-vivo behavior. Hence, it can be concluded that APPCs are exchangeable with other vegetable and gelatin shells.

  3. Comparative analysis of EPA and DHA in fish oil nutritional capsules by GC-MS.

    Science.gov (United States)

    Yi, Tao; Li, Shuk-Man; Fan, Jia-Yi; Fan, Lan-Lan; Zhang, Zhi-Feng; Luo, Pei; Zhang, Xiao-Jun; Wang, Jian-Gang; Zhu, Lin; Zhao, Zhong-Zhen; Chen, Hu-Biao

    2014-12-13

    Fish oil is a popular nutritional product consumed in Hong Kong. Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are the two main bioactive components responsible for the health benefits of fish oil. Market survey in Hong Kong demonstrated that various fish oil capsules with different origins and prices are sold simultaneously. However, these capsules are labelled with same ingredient levels, namely EPA 180 mg/g and DHA 120 mg/g. This situation makes the consumers very confused. To evaluate the quality of various fish oil capsules, a comparative analysis of the contents of EPA and DHA in fish oil is crucial. A gas chromatography-mass spectrometry (GC-MS) method was developed for identification and determination of EPA and DHA in fish oil capsules. A comprehensive validation of the developed method was conducted. Ten batches of fish oil capsules samples purchased from drugstores of Hong Kong were analyzed by using the developed method. The present method presented good sensitivity, precision and accuracy. The limits of detection (LOD) for EPA and DHA were 0.08 ng and 0.21 ng, respectively. The relative standard deviation (RSD) values of EPA and DHA for repeatability tests were both less than 1.05%; and the recovery for accuracy test of EPA and DHA were 100.50% and 103.83%, respectively. In ten fish oil samples, the contents of EPA ranged from 39.52 mg/g to 509.16 mg/g, and the contents of DHA ranged from 35.14 mg/g to 645.70 mg/g. The present method is suitable for the quantitative analysis of EPA and DHA in fish oil capsules. There is a significant variation in the contents of the quantified components in fish oil samples, and there is not a linear relationship between price and contents of EPA and DHA. Strict supervision of the labelling of the fish oil capsules is urgently needed.

  4. New reduced volume preparation regimen in colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Yasuo Kakugawa; Kazuhide Higuchi; Shinji Tanaka; Hideki Ishikawa; Hisao Tajiri; Yutaka Saito; Shoichi Saito; Kenji Watanabe; Naoki Ohmiya; Mitsuyuki Murano; Shiro Oka; Tetsuo Arakawa; Hidemi Goto

    2012-01-01

    AIM:To evaluate the effectiveness of our proposed bowel preparation method for colon capsule endoscopy.METHODS:A pilot,multicenter,randomized controlled trial compared our proposed "reduced volume method" (group A) with the "conventional volume method" (group B) preparation regimens.Group A did not drink polyethylene glycol electrolyte lavage solution (PEGELS) the day before the capsule procedure,while group B drank 2 L.During the procedure day,groups A and B drank 2 L and 1 L of PEG-ELS,respectively,and swallowed the colon capsule (PillCam COLON(R) capsule).Two hours later the first booster of 100 g magnesium citrate mixed with 900 mL water was administered to both groups,and the second booster was administered six hours post capsule ingestion as long as the capsule had not been excreted by that time.Capsule videos were reviewed for grading of cleansing level.RESULTS:Sixty-four subjects were enrolled,with results from 60 analyzed.Groups A and B included 31 and 29 subjects,respectively.Twenty-nine (94%) subjects in group A and 25 (86%) subjects in group B had adequate bowel preparation (ns).Twenty-two (71%) of the 31 subjects in group A excreted the capsule within its battery life compared to 16 (55%) of the 29 subjects in group B (ns).Of the remaining 22 subjects whose capsules were not excreted within the battery life,all of the capsules reached the left side colon before they stopped functioning.A single adverse event was reported in one subject who had mild symptoms of nausea and vomiting one hour after starting to drink PEG-ELS,due to ingesting the PEG-ELS faster than recommended.CONCLUSION:Our proposed reduced volume bowel preparation method for colon capsule without PEG-ELS during the days before the procedure was as effective as the conventional volume method.

  5. 21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.

    Science.gov (United States)

    2010-04-01

    ... § 876.1300 Ingestible telemetric gastrointestinal capsule imaging system. (a) Identification. An ingestible telemetric gastrointestinal capsule imaging system is used for visualization of the small bowel... Special Controls Guidance Document: Ingestible Telemetric Gastrointestinal Capsule Imaging Systems;...

  6. Potassium iodide capsule treatment of feline sporotrichosis.

    Science.gov (United States)

    Reis, Erica G; Gremião, Isabella D F; Kitada, Amanda A B; Rocha, Raphael F D B; Castro, Verônica S P; Barros, Mônica B L; Menezes, Rodrigo C; Pereira, Sandro A; Schubach, Tânia M P

    2012-06-01

    Sporotrichosis is a mycosis caused by Sporothrix schenckii. The most affected animal is the cat; it has played an important role in the zoonotic transmission of this disease, especially in Rio de Janeiro, Brazil, since 1998. In order to evaluate the treatment of feline sporotrichosis with potassium iodide, an observational cohort was conducted in 48 cats with sporotrichosis at Instituto de Pesquisa Clínica Evandro Chagas, Fiocruz. All cats received potassium iodide capsules, 2.5 mg/kg to 20 mg/kg q24h. The cure rate was 47.9%, treatment failure was 37.5%, treatment abandonment was 10.4% and death was 4.2%. Clinical adverse effects were observed in 52.1% of the cases. Thirteen cats had a mild increase in hepatic transaminase levels during the treatment, six of them presented clinical signs suggestive of hepatotoxicity. Compared to previous studies with itraconazole and iodide in saturated solution, potassium iodide capsules are an alternative for feline sporotrichosis treatment.

  7. Orbital Thermal Control of the Mercury Capsule

    Science.gov (United States)

    Weston, Kenneth C.

    1960-01-01

    The approach to orbital thermal control of the Project Mercury capsule environment is relatively unsophisticated compared with that for many unmanned satellites. This is made possible by the relatively short orbital flight of about 4 1/2 hours and by the presence of the astronaut who is able to monitor the capsule systems and compensate for undesirable thermal conditions. The general external features of the Mercury configuration as it appears in the orbital phase of flight are shown. The conical afterbody is a double-wall structure. The inner wall serves as a pressure vessel for the manned compartment, and the outer wall, of shingle type construction, acts as a radiating shield during reentry. Surface treatment of the shingles calls for a stably oxidized surface to minimize reentry temperatures. The shingles are supported by insulated stringers attached to the inner skin. Areas between stringers are insulated by blankets of Thermoflex insulation. This insulation is especially effective at high altitude due to the reduction of its thermal conductivity with decreasing pressure. As a result of the design of the afterbody for the severe reentry conditions, the heat balance on the manned compartment indicates the necessity for moderate internal cooling to compensate for the heat generation due to human and electrical sources. This cooling is achieved by the controlled vaporization of water in the cabin and astronaut-suit heat exchangers.

  8. Posterior capsule opacification. Part 1: Experimental investigations.

    Science.gov (United States)

    Nishi, O

    1999-01-01

    Posterior capsule opacification (PCO) is the most frequent complication associated with decreased vision after cataract surgery. Previous methods of preventing PCO have not proven to be practical, effective, and safe for routine clinical procedure, but some novel concepts and methods have recently been developed. This 2-part review looks at clinical and experimental investigations of PCO, focusing on developments since 1992. Clinical aspects will be presented in a later issue. This paper addresses (1) in vitro models for PCO research; (2) pathophysiology and molecular biology of lens epithelial cells (LECs); (3) prevention of PCO. Of special interest are methods of culturing human LECs obtained by capsulotomy during cataract surgery, including those obtained with an intact capsular bag, to provide an in vitro model for investigating the pathophysiology of LECs; the effect of a sharp bend in the lens capsule that induces contact inhibition of migrating LECs; more specific inhibition of migrating LECs using an immunotoxin, b-FGF-saporin, or EDTA and RGD-peptides.

  9. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  10. Representing properties locally.

    Science.gov (United States)

    Solomon, K O; Barsalou, L W

    2001-09-01

    Theories of knowledge such as feature lists, semantic networks, and localist neural nets typically use a single global symbol to represent a property that occurs in multiple concepts. Thus, a global symbol represents mane across HORSE, PONY, and LION. Alternatively, perceptual theories of knowledge, as well as distributed representational systems, assume that properties take different local forms in different concepts. Thus, different local forms of mane exist for HORSE, PONY, and LION, each capturing the specific form that mane takes in its respective concept. Three experiments used the property verification task to assess whether properties are represented globally or locally (e.g., Does a PONY have mane?). If a single global form represents a property, then verifying it in any concept should increase its accessibility and speed its verification later in any other concept. Verifying mane for PONY should benefit as much from having verified mane for LION earlier as from verifying mane for HORSE. If properties are represented locally, however, verifying a property should only benefit from verifying a similar form earlier. Verifying mane for PONY should only benefit from verifying mane for HORSE, not from verifying mane for LION. Findings from three experiments strongly supported local property representation and ruled out the interpretation that object similarity was responsible (e.g., the greater overall similarity between HORSE and PONY than between LION and PONY). The findings further suggest that property representation and verification are complicated phenomena, grounded in sensory-motor simulations.

  11. Morpho-functional evaluation of small bowel using wireless motility capsule and video capsule endoscopy in patients with known or suspected Crohn’s disease: pilot study

    Science.gov (United States)

    Yung, Diana; Douglas, Sarah; Hobson, Anthony R.; Giannakou, Andry; Plevris, John N.; Koulaouzidis, Anastasios

    2016-01-01

    Background and study aims: SmartPill® (Given Imaging Corp.,Yoqneam,Israel) is an ingestible, non-imaging capsule that records physiological data including contractions and pH throughout the gastrointestinal tract. There are scarce data looking at SmartPill® assessment of patients with known/suspected small-bowel Crohn’s Disease (CD). This pilot study aims to investigate feasibility and safety of SmartPill® to assess gut motility in this group.  Patients and methods: Over 1 year, patients with known/suspected CD, referred for small-bowel capsule endoscopy (SBCE), were invited to participate and 12 were recruited (7 female, 5 male, mean age 44.2 ± 16.6 years). They underwent hydrogen breath test to exclude small-bowel bacterial overgrowth, patency capsule (Agile®), and provided stool samples for fecal calprotectin (FC). Patients ingested PillCam®SB2 and SmartPill® 4 hours apart. Using unpublished data, 33 healthy controls also were identified for the study. P < 0.05 was considered statistically significant. Results: Of the 12 patients enrolled, 10 underwent complete Smartpill® examination (1 stomach retention, 1 dropout). Pillcam® was complete in 10 (1 dropout, 1 stomach retention). Mean fecal calprotectin was 340 ± 307.71 mcg/g. The study group had longer transit times and lower gut motility index than did the controls. The difference in motility appears to be statistically significant (P < 0.05). Longer transit times for SmartPill® (not statistically significant) may have been due to different specifications between the capsules. Limitations included transient Smartpill® signal loss (5/10 studies). Conclusions: This is the first pilot to attempt combining SBCE and SmartPill® to assess small-bowel CD. Data on motility in CD are scarce. Multimodal information can provide a clearer clinical picture. Despite concerns about capsule retention in CD patients, SmartPill® seems safe for use if a patency capsule is employed beforehand. PMID

  12. Representing and Performing Businesses

    DEFF Research Database (Denmark)

    Boll, Karen

    2014-01-01

    and MacKenzie’s idea of performativity. Based on these two approaches, the article demonstrates that the segmentation model represents and performs the businesses as it makes up certain new ways to be a business and as the businesses can be seen as moving targets. Inspired by MacKenzie the argument......This article investigates a segmentation model used by the Danish Tax and Customs Administration to classify businesses’ motivational postures. The article uses two different conceptualisations of performativity to analyse what the model’s segmentations do: Hacking’s notion of making up people...... is that the segmentation model embodies cleverness in that it simultaneously alters what it represents and then represents this altered reality to confirm the accuracy of its own model of the businesses’ postures. Despite the cleverness of the model, it also has a blind spot. The model assumes a world wherein everything...

  13. The effects of Xingnao Jieyu capsules on post-stroke depression are similar to those of fluoxetine*

    Institute of Scientific and Technical Information of China (English)

    Yongmei Yan; Wentao Fan; Li Liu; Ru Yang; Wenjia Yang

    2013-01-01

    The Xingnao Jieyu capsule has been shown to effectively relieve neurologic impairments and lessen depression. It remains poorly understood whether this capsule can be used to treat post-stroke depression. Thus, in the present study, we established a rat model of post-stroke de-pression using left middle cerebral artery occlusions in combination of chronic unpredictable stress and solitary housing during development. Experimental rats received intragastric perfusion with 0.82, 0.41, and 0.20 g/kg Xingnao Jieyu capsules separately dissolved in 2 mL distil ed water. Fluoxetine served as a positive control. The treatment was conducted over 28 days. Sugar water consumption test, open-field test, real-time fluorescent quantitative PCR and immunohistochemical staining re-sults demonstrated that intragastric perfusion with various doses of Xingnao Jieyu capsules in-creased sugar water consumption, voluntary behaviors and synaptotagmin mRNA and protein ex-pression in rats with post-stroke depression. These therapeutic effects were similar to those of fluoxetine. These results indicate that Xingnao Jieyu capsules upregulate synaptotagmin expres-sion in hippocampi of rats with post-stroke depression, and exert antidepressant effects.

  14. Triple-ion interactions for the construction of supramolecular capsules

    NARCIS (Netherlands)

    Oshovsky, G.; Reinhoudt, David; Verboom, Willem

    2006-01-01

    A novel type of [2+4] capsules based on triple-ion interactions was obtained. Four monovalent anions (bromide, nitrate, acetate, and tosylate) bring together two tetrakis(pyridiniummethyl)tetramethyl cavitands by pyridinium−anion−pyridinium interactions. ESI-MS experiments have confirmed the capsule

  15. Experimental measurement on movement of spiral-type capsule endoscope

    Directory of Open Access Journals (Sweden)

    Yang W

    2016-01-01

    Full Text Available Wanan Yang,1 Houde Dai,2 Yong He,1 Fengqing Qin1 1School of Computer and Information Engineering, Yibin University, Yibin, Sichuan, People's Republic of China; 2Quanzhou Institute of Equipment Manufacturing, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Quanzhou, People's Republic of China Abstract: Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. Keywords: wireless capsule endoscope, magnet ring, magnetic driving, spiral structure, torque  

  16. Risk factors for incomplete small-bowel capsule endoscopy

    NARCIS (Netherlands)

    Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2009-01-01

    Background: In 20% to 30% of capsule endoscopy (CE) procedures, the capsule does not reach the cecum within recording time, with incomplete imaging of the small bowel, which limits the value of CE. Objective: To identify possible risk factors for incomplete small-bowel CE examinations. Design: Data

  17. Material properties of the human posterior knee capsule

    NARCIS (Netherlands)

    Rachmat, H.H.; Janssen, D.W.; van Tienen, T.; Diercks, R.L.; Verkerke, Gijsbertus Jacob; Verdonschot, Nicolaas Jacobus Joseph; Fernandes, Paulo; Folgado, Joao; Silva, Miguel

    2012-01-01

    BACKGROUND: There is considerable interest to develop accurate subject-specific biomechanical models of the knee. Most of the existing models currently do not include a representation of the posterior knee capsule. In order to incorporate the posterior capsule in knee models, data is needed on its

  18. Experimental modulation of capsule size in Cryptococcus neoformans

    Directory of Open Access Journals (Sweden)

    Zaragoza Oscar

    2004-01-01

    Full Text Available Experimental modulation of capsule size is an important technique for the study of the virulence of the encapsulated pathogen Cryptococcus neoformans. In this paper, we summarize the techniques available for experimental modulation of capsule size in this yeast and describe improved methods to induce capsule size changes. The response of the yeast to the various stimuli is highly dependent on the cryptococcal strain. A high CO2 atmosphere and a low iron concentration have been used classically to increase capsule size. Unfortunately, these stimuli are not reliable for inducing capsular enlargement in all strains. Recently we have identified new and simpler conditions for inducing capsule enlargement that consistently elicited this effect. Specifically, we noted that mammalian serum or diluted Sabouraud broth in MOPS buffer pH 7.3 efficiently induced capsule growth. Media that slowed the growth rate of the yeast correlated with an increase in capsule size. Finally, we summarize the most commonly used media that induce capsule growth in C. neoformans.

  19. [Safety of promestriene capsule used in postmenopausal atrophic vaginitis].

    Science.gov (United States)

    Sun, Ai-jun; Lin, Shou-qing; Jing, Lian-hong; Wang, Zi-yi; Ye, Jia-lin; Zhang, Ying

    2009-08-01

    To investigate the safety and efficacy of promestriene capsule used in the treatment of postmenopausal atrophic vaginitis. Fifty-three women at age of 45 - 75 years (more than one year history of menopause) diagnosed with postmenopausal atrophic vaginitis were enrolled in self-control study. They all had typicalsymptoms of postmenopausal vaginitis. Promestriene was given by continuous therapy for 20 days, then maintenance therapy for for 8 weeks (1 pill two times per week used). The level of follicle stimulation hormone (FSH) and estradiol (E(2)) in serum was and thickness of endometrium were detected before and after treatment. The routine biochemical test was used as index to monitoring the safety. The vaginal mature index (VMI), the atrophic vaginitis evaluating score and vaginal healthy evaluating score were evaluated for therapeutic effect. In the mean time, adverse effect was recorded. (1) SAFETY: during promestriene treatment, no case with adverse effect was observed. Before treatment, the mean level of FSH and E(2) was (71 +/- 3) U/L and (41 +/- 18) pmol/L, the mean thickness of endometrium was (2.4 +/- 0.9) mm. After treatment, the mean level of FSH and E(2) was (67 +/- 22) U/L and (43 +/- 37) pmol/L, the mean thickness of endometrium was (2.5 +/- 1.3) mm. No significant difference was observed (P > 0.05). (2) Therapeutic effect: VMI were 42 +/- 15 before and 54 +/- 8 after treatment. The atrophic vaginitis evaluating score were 3.4 +/- 1.7 before and 1.5 +/- 1.4 after treatment. Vaginal healthy evaluating score were 7.8 +/- 2.4 before and 12.0 +/- 2.4 after treatment. They all showed significant difference (P vaginal bleeding, 3 cases with breast nodules and 1 case with cervical polyp was observed, however, it was uncertain whether those events were associated with promestriene use. The premestriene capsule was safe and effective in the treatment of postmenopausal atrophic vaginitis.

  20. Analysing intracellular deformation of polymer capsules using structured illumination microscopy

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank

    2016-06-01

    Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces

  1. Tethered SECM endoscopic capsule for the diagnosis of eosinophilic esophagitis (Conference Presentation)

    Science.gov (United States)

    Do, Dukho; Kang, DongKyun; Tabatabaei, Nima; Grant, Catriona N.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.

    2017-02-01

    Eosinophilic Esophagitis (EoE) is an inflammatory disease caused by inhaled or ingested food allergies, and characterized by the infiltration of eosinophils in the esophagus. The gold standard for diagnosing EoE is to conduct endoscopy and obtain multiple biopsy specimens from different portions of the esophagus; an exam is considered positive if more than 15 eosinophils per high power field (HPF) in any of the biopsies. This method of diagnosis is problematic because endoscopic biopsy is expensive and poorly tolerated and the esophageal eosinophil burden needs to be monitored frequently during the course of the disease. Spectrally encoded confocal microscopy (SECM) is a high-speed confocal microscopy technology that can visualize individual eosinophils in large microscopic images of the human esophagus, equivalent to more than 30,000 HPF. Previously, we have demonstrated that tethered capsule SECM can be conducted in unsedated subjects with diagnosed EoE. However, speckle noise and the relatively low resolution in images obtained with the first capsule prototypes made it challenging to distinguish eosinophils from other cells. In this work, we present a next-generation tethered SECM capsule, which has been modified to significantly improve image quality. First, we substituted the single mode fiber with a dual-clad fiber to reduce speckle noise. A gradient-index multimode fiber was fusion spliced at the tip of the dual-clad fiber to increase the effective numerical aperture of the fiber from 0.09 to 0.15, expanding the beam more rapidly to increase the illumination aperture at the objective. These modifications enabled the new SECM capsule to achieve a lateral resolution of 1.8 µm and an axial resolution of 16.1 µm, which substantially improves the capacity of this probe to visualize cellular features in human tissue. The total size of the SECM capsule remained 6.75 mm in diameter and 31 mm in length. We are now in the process of testing this new SECM capsule in

  2. Visualization of Capsule Reentry Vehicle Heat Shield Ablation Using Naphthalene PLIF

    Science.gov (United States)

    Combs, Christopher S.; Clemens, Noel T.; Danehy, Paul M.

    2014-01-01

    The Orion Multi-Purpose Crew Vehicle (MPCV) will use an ablative heat shield and improved understanding of the ablation process would be beneficial for design purposes. Given that ablation is a multi-physics process involving heat and mass transfer, codes aiming to predict heat shield ablation are in need of experimental data pertaining to the turbulent transport of ablation products for validation. At The University of Texas at Austin, a technique is being developed that uses planar laser-induced fluorescence (PLIF) of a low-temperature sublimating ablator (naphthalene) to visualize the transport of ablation products in a supersonic flow. Since ablation at reentry temperatures can be difficult to recreate in a laboratory setting it is desirable to create a limited physics problem and simulate the ablation process at relatively low temperature conditions using naphthalene. A scaled Orion MPCV model with a solid naphthalene heat shield has been tested in a Mach 5 wind tunnel at various angles of attack in the current work. PLIF imaging reveals the distribution of the ablation products as they are transported into the heat-shield boundary layer and over the capsule shoulders into the separated shear layer and backshell recirculation region. Visualizations of the capsule shear layer using both naphthalene PLIF and Schlieren imaging compared favorably. High concentrations of naphthalene in the capsule separated flow region, intermittent turbulent structures on the heat shield surface, and interesting details of the capsule shear layer structure were observed using the naphthalene PLIF technique. The capsule shear layer was also shown to generally appear to be more turbulent at lower angles of attack. Furthermore, the PLIF signal increased steadily over the course of a run indicating that during a wind tunnel run the model heated up and the rate of naphthalene ablation increased. The shear layer showed increasing signs of turbulence over the course of a wind tunnel run

  3. Tethered capsule OCT endomicroscopy: from bench to bedside at the primary care office (Conference Presentation)

    Science.gov (United States)

    Gora, Michalina J.; Simmons, Leigh H.; Tiernan, Aubrey R.; Grant, Catriona N.; Soomro, Amna R.; Walker Corkery, Elizabeth S.; Rosenberg, Mireille; Metlay, Joshua P.; Tearney, Guillermo J.

    2016-03-01

    We have developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires microscopic images of the entire esophagus in unsedated subjects in a quick and comfortable procedure. To test its capabilities of TCE to become a population-based screening device, we conducted a clinical feasibility study in the primary care office. The swept-source OCT imaging system (1310nm central wavelength, 40kHz A-line rate, 10um axial resolution) together with the tethered capsule catheter (11x25mm capsule attached to a flexible tether) were transferred to the PCP office where unsedated patients scheduled for non-urgent PCP visits swallowed the capsule and microscopic OCT images of the entire esophagus were collected. After the whole length of the esophagus was imaged, the catheter was disinfected for reuse. Twenty subjects were enrolled in the study, including nine female and eleven male. All TCE procedures were performed by a nurse and lasted in average 5:42 ± 1:54 min. High-resolution images of the esophagus were obtained in all seventeen subjects that swallowed the capsule. Our clinical experience in this cohort, subject feedback, image quality, and technological adaptations for efficient utilization in this setting will be presented. The ease and simplicity of the procedure combined with high quality of the images demonstrate the potential for this technology to become a population-based screening device. Technology limitations and future development guided by findings from this initial experience will be discussed with the goal of effectively translating TCE to the outpatient primary care setting.

  4. Development of methods for determination of phenolic acids and flavonoids in capsules containing Corylus avellana L. Dry extract

    Directory of Open Access Journals (Sweden)

    Nataliya Blyznyuk

    2016-03-01

    Full Text Available The questions of standardization and quality control of both herbs and herbal remedies remain relevant, because it is well-known that product quality standards are essential, whether consumer using herbs or drugs. The necessity of the standardization methods development for the initial herbal material and capsule dosage form for the further quality control under manufacturing conditions remains relevant.Aim. The aim of our research was to develop simple, specific, accurate and reproducible methods for identification of flavonoids and phenolic acids in capsule dosage form containing Corylus avellana L. dry extract.Methods. The samples of gelatine capsules containing Corylus avellana L. dry extract for oral administration were analyzed. The analysis was carried out using Camag HPTLC system.The absorption spectroscopy determination of the sum of flavonoids was carried out using THERMO Scientific Evolution 60S Spectroscope in wavelength range of 300–600 nm.Results. As a result of HPTLC research rutine and quercitrine have been identified in capsule dosage form containing Corylus avellana L. dry extract. Among phenolic acids, neochlorogenic and chlorogenic acids have been identified.Under the given conditions, the spectrum of the test solution had a maximum absorption at wavelength 406 nm. The analysis of flavonoids total content in gelatine capsules containing Corylus avellana L. dry extract calculated as rutine has shown the content of 1,7 %.Conclusion. Effective HPTLC and absorption spectroscopy methods for determination of flavonoids and phenolic acids in capsule dosage form containing Corylus avellana L. dry extract have been developed. It has been found that described methods are promising enough for standardization of capsules with Corylus avellana L. dry extract and may be suggested for the quality control of the dosage form under manufacturing conditions

  5. Aero-thermo-dynamic analysis of a low ballistic coefficient deployable capsule in Earth re-entry

    Science.gov (United States)

    Zuppardi, G.; Savino, R.; Mongelluzzo, G.

    2016-10-01

    The paper deals with a microsatellite and the related deployable recovery capsule. The aero-brake is folded at launch and deployed in space and is able to perform a de-orbiting controlled re-entry. This kind of capsule, with a flexible, high temperature resistant fabric, thanks to its lightness and modulating capability, can be an alternative to the current "conventional" recovery capsules. The present authors already analyzed the trajectory and the aerodynamic behavior of low ballistic coefficient capsules during Earth re-entry and Mars entry. In previous studies, aerodynamic longitudinal stability analysis and evaluation of thermal and aerodynamic loads for a possible suborbital re-entry demonstrator were carried out in both continuum and rarefied regimes. The present study is aimed at providing preliminary information about thermal and aerodynamic loads and longitudinal stability for a similar deployable capsule, as well as information about the electronic composition of the plasma sheet and its possible influence on radio communications at the altitudes where GPS black-out could occur. Since the computer tests were carried out at high altitudes, therefore in rarefied flow fields, use of Direct Simulation Monte Carlo codes was mandatory. The computations involved both global aerodynamic quantities (drag and longitudinal moment coefficients) and local aerodynamic quantities (heat flux and pressure distributions along the capsule surface). The results verified that the capsule at high altitude (150 km) is self-stabilizing; it is stable around the nominal attitude or at zero angle of attack and unstable around the reverse attitude or at 180° angle of attack. The analysis also pointed out the presence of extra statically stable equilibrium trim points.

  6. Design and fabrication report on instrumented capsule (99M-01K.02H) for korean reactor pressure vessel material made by HANJUNG (Co)

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kang, Y. H.; Kim, B. G.; Cho, M. S.; Son, J. M.; Kim, D. S.; Oh, J. M.; Park, S. J.; Shin, Y. T

    2000-09-01

    The instrumented capsules (99M-01K{center_dot}02H) was designed and fabricated. The purpose of the capsules were to evaluate the nuclear irradiation performance of the Korean nuclear reactor pressure vessel material, SA508 class 3 steel, fabricated by HANJUNG Co for Yonggwang Units 4,5 and Ulchin Unit 4. There are 5 stages having specimens and independent electric heaters in the capsule mainbody. 12 K-type thermocouples and 5 sets of Ni-Ti-Fe and sapphire neutron Fluence Monitors were also inserted in the apsule. Various types of specimens, such as round compact tension, Charpy insert, pre-cracked v-notch (PCVN), tensile, small punch (SP), magnetic Barkhausen effect (MBE), and transmission electron micrograph (TEM) specimens, were inserted in the capsule. The capsule was fabricated at DAEWOO Precision Co. according to KAERI detailed design specifications. This report describes the details of the design, fabrication and inspection of the 99M-01K and 99M-02H capsule. The capsules were irradiated in the IR2 test hole of HANARO at 290{+-}10 deg C up to the fast neutron fluence (E>1.0 MeV) of 3.0x10{sup 19} (n/cm{sup 2})

  7. Non-capsulated and capsulated Haemophilus influenzae in children with acute otitis media in Venezuela: a prospective epidemiological study

    Directory of Open Access Journals (Sweden)

    Naranjo Laura

    2012-02-01

    Full Text Available Abstract Background Non-typeable Haemophilus influenzae (NTHi and Streptococcus pneumoniae are major causes of bacterial acute otitis media (AOM. Data regarding AOM are limited in Latin America. This is the first active surveillance in a private setting in Venezuela to characterize the bacterial etiology of AOM in children Methods Between December 2008 and December 2009, 91 AOM episodes (including sporadic, recurrent and treatment failures were studied in 87 children enrolled into a medical center in Caracas, Venezuela. Middle ear fluid samples were collected either by tympanocentesis or spontaneous otorrhea swab sampling method. Standard laboratory and microbiological techniques were used to identify bacteria and test for antimicrobial resistance. The results were interpreted according to Clinical Laboratory Standards Institute (CLSI 2009 for non-meningitis isolates. All statistical analyses were performed using SAS 9.1 and Microsoft Excel (for graphical purposes. Results Overall, bacteria were cultured from 69.2% (63 of the 91 episodes; at least one pathogen (S. pneumoniae, H. influenzae, S. pyogenes or M. catarrhalis was cultured from 65.9% (60/91 of episodes. H. influenzae (55.5%; 35/63 episodes and S. pneumoniae (34.9%; 22/63 episodes were the most frequently reported bacteria. Among H. influenzae isolates, 62.9% (22/35 episodes were non-capsulated (NTHi and 31.4% (11/35 episodes were capsulated including types d, a, c and f, across all age groups. Low antibiotic resistance for H. influenzae was observed to amoxicillin/ampicillin (5.7%; 2/35 samples. NTHi was isolated in four of the six H. influenzae positive samples (66.7% from recurrent episodes. Conclusions We found H. influenzae and S. pneumoniae to be the main pathogens causing AOM in Venezuela. Pneumococcal conjugate vaccines with efficacy against these bacterial pathogens may have the potential to maximize protection against AOM.

  8. Optimal Bowel Preparation for Video Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Hyun Joo Song

    2016-01-01

    Full Text Available During video capsule endoscopy (VCE, several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG- based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE.

  9. Vortex Rings from Sphagnum Moss Capsules

    CERN Document Server

    Chang, Emily S; Cha, Jung Ha; Strassman, Sam; Hard, Clara; Whitaker, Dwight L

    2010-01-01

    Long distance wind dispersal requires small spores with low terminal velocities, which can be held aloft by turbulent air currents until they are deposited in suitable habitats for colonization. The inherent difficulty in dispersing spores by wind is that spores easily carried by wind are also rapidly decelerated when moving through still air. Thus the height of spore release is critical in determining their range of dispersal. Vascular plants with wind dispersed spores use the height of the plant to lift spores into sufficient wind currents for dispersal, however non-vascular plants such as Sphagnum cannot grow sufficiently tall. These fluid dynamics videos show how exploding capsules of {\\em Sphagnum} moss generate vortex rings to carry spores to heights above 10 cm with an initial velocity of 16 m s$^{-1}$. In contrast spores launched ballistically at these speeds through still air would travel only 2-7 mm.

  10. A comparative study on liquid core formulation on the diameter on the alginate capsules

    Science.gov (United States)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  11. Development of Electrical Capacitance Sensors for Accident Tolerant Fuel (ATF) Testing at the Transient Reactor Test (TREAT) Facility

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Maolong; Ryals, Matthew; Ali, Amir; Blandford, Edward; Jensen, Colby; Condie, Keith; Svoboda, John; O' Brien, Robert

    2016-08-01

    A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.

  12. An Analysis of the Thermal and Structure Behaviour of the UO{sub 2}-PuO{sub 2}-Fuel in the Irradiation Experiment of the UO{sub 2}-PuO{sub 2}-Fuel in the Irradiation Experiment FR2 Capsule Test Series 5a; Analisis termico y estructural del combustible UO{sub 2}-PuO{sub 2} irradiado en el reactor FR2 dentro del experimento KVE-Vg.5a

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Jimenez, J.; Helmut, E.

    1981-07-01

    In the Karlsruhe research reactor FR2 nine fuel pins were irradiated within three irradiation capsules in the course of the test series 5a. The pins contained UO{sub 2}-PuO{sub 2} fuel pellets. They reached bump values of about 6, 17 and 47 Mwd/Kg Me with linear rod powers of 400 to 600 W/cm and clad surface temperature between 500 and 700 degree centigree. A detailed analysis of the fuel structuration data (columnar-grain and equiaxed- -grain growth regions) have allowed to determine, with the help of physic-mathematical models, the radii of these regions and the heat transfer through the contact zone between fuel and clad depending on the bump. The results of the analysis showed that the fuel surface temperature rose with increasing burnup. (Author) 16 refs.

  13. In vitro study on sustained release capsule formulation of acetazolamide.

    Science.gov (United States)

    Pandey, V P; Kannan, K; Manavalan, R; Desai, N

    2003-10-01

    In the present study formulation of sustained release capsule of acetazolamide 250 mg was tried using nonpareil seeds. Nonpareil seeds were coated with drug, polyvinylpyrrolidone, glyceryl monostearate, microcrystalline wax, and glyceryl distearate either individually or in combination to achieve sustained release capsule 250 mg. In successful formulation 20% drug coated pellets and 80% wax coated pellets were taken. Wax coated pellets for successful formulation contained coating of microcrystalline wax and glyceryl distearate on drug coated pellets of the same concentration of 1.6% w/w. Successful formulated sustained release capsule 250 mg of acetazolamide was compared in in vitro study with theoretical sustained release formulation suggested by wagner and one marketed sustained release capsule 250 mg. Formulated capsule showed result superior to or on par with marketed capsule. For successful formulation pellets were filled in '1' size hard gelatin capsule and stability study was carried out in hot air over at room temperature and 45 degrees C for 5 weeks. The formulation was found stable in respect of drug content and release rate.

  14. Tuning the Properties of Polymer Capsules for Cellular Interactions.

    Science.gov (United States)

    Sun, Huanli; Cui, Jiwei; Ju, Yi; Chen, Xi; Wong, Edgar H H; Tran, Jenny; Qiao, Greg G; Caruso, Frank

    2017-07-19

    Particle-cell interactions are governed by, among other factors, the composition and surface properties of the particles. Herein, we report the preparation of various polymer capsules with different compositions and properties via atom transfer radical polymerization mediated continuous assembly of polymers (CAPATRP), where the cellular interactions of these capsules, particularly fouling and specific targeting, are examined by flow cytometry and deconvolution microscopy. Acrylated eight-arm poly(ethylene glycol) (8-PEG) and poly(N-(2-hydroxypropyl)-methacrylamide) (PHPMA) as well as methacrylated hyaluronic acid (HA), poly(glutamic acid) (PGA), and poly(methacrylic acid) (PMA) are used as macro-cross-linkers to obtain a range of polymer capsules with different compositions (PEG, PHPMA, HA, PGA, and PMA). Capsules composed of low-fouling polymers, PEG and PHPMA, show negligible association with macrophage Raw 264.7, monocyte THP-1, and HeLa cells. HA capsules, although moderately low-fouling (capsules show high cellular association toward phagocytic Raw 264.7 and THP-1 cells. These findings demonstrate the capability of the CAPATRP technique in preparing polymer capsules with specific cellular interactions.

  15. Albumin/asparaginase capsules prepared by ultrasound to retain ammonia.

    Science.gov (United States)

    Tinoco, Ana; Ribeiro, Artur; Oliveira, César; Parpot, Pier; Gomes, Andreia; Cavaco-Paulo, Artur

    2016-11-01

    Asparaginase reduces the levels of asparagine in blood, which is an essential amino acid for the proliferation of lymphoblastic malign cells. Asparaginase converts asparagine into aspartic acid and ammonia. The accumulation of ammonia in the bloodstream leads to hyperammonemia, described as one of the most significant side effects of asparaginase therapy. Therefore, there is a need for asparaginase formulations with the potential to reduce hyperammonemia. We incorporated 2 % of therapeutic enzyme in albumin-based capsules. The presence of asparaginase in the interface of bovine serum albumin (BSA) capsules showed the ability to hydrolyze the asparagine and retain the forming ammonia at the surface of the capsules. The incorporation of Poloxamer 407 in the capsule formulation further increased the ratio aspartic acid/ammonia from 1.92 to 2.46 (and 1.10 from the free enzyme), decreasing the levels of free ammonia. This capacity to retain ammonia can be due to electrostatic interactions and retention of ammonia at the surface of the capsules. The developed BSA/asparaginase capsules did not cause significant cytotoxic effect on mouse leukemic macrophage cell line RAW 264.7. The new BSA/asparaginase capsules could potentially be used in the treatment of acute lymphoblastic leukemia preventing hyperammonemia associated with acute lymphoblastic leukemia (ALL) treatment with asparaginase.

  16. Patency(C) and agile(C) capsules

    Institute of Scientific and Technical Information of China (English)

    àngel Caunedo-àlvarez; Javier Romero-Vazquez; Juan M Herrerias-Gutierrez

    2008-01-01

    Small bowel strictures can be missed by current diagnostic methods.The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract,in a non-invasive manner.The available clinical trials have demonstrated that the Patency(C) capsule is a good tool for assessment of the functional patency of the small bowel,and it allows identification of those patients who can safely undergo a capsule endoscopy,despite clinical and radiographic evidence of small-bowel obstruction.Some cases of intestinal occlusion have been reported with the Patency(C) capsule,four of them needed surgery.So,a new capsule with two timer plugs (Agile(C) capsule) has been recently developed in order to minimize the risk of occlusion.This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture.

  17. Emerging Issues and Future Developments in Capsule Endoscopy.

    Science.gov (United States)

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-01-01

    Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting.

  18. Outer membrane protein profiling to distinguish between Haemophilus aegyptius and non-capsulate Haemophilus influenzae biotype III.

    Science.gov (United States)

    Leaves, N I; Anderson, E C; Toy, S J

    1994-12-01

    Outer membrane protein profiling was used to assist in determining the identity of an isolate of Haemophilus spp. that was presumptively identified as non-capsulate Haemophilus influenzae biotype III. The possibility that this strain was in fact Haemophilus aegyptius was queried because of clinical information and the source of the isolate. Sodium dodecyl-sulphate polyacrylamide gel electrophoresis was used to establish the identity of the isolate as non-capsulate H. influenzae biotype III and no H. aegyptius. Generally, protein profiling compared very favourably with other standard tests for identifying H. aegyptius: the method was easily and rapidly performed and gave an unequivocal result.

  19. Preparation of capsules containing rejuvenators for their use in asphalt concrete.

    Science.gov (United States)

    García, Alvaro; Schlangen, Erik; van de Ven, Martin; Sierra-Beltrán, Guadalupe

    2010-12-15

    Every year, there is a demand of more than 110 million metric tons of asphalt all around the world. This represents a huge amount of money and energy, from which a good part is for the preservation and renovation of the existing pavements. The problem of asphalt is that it oxidizes with time and therefore its beneficial properties disappear. Traditionally, rejuvenators spread in the road surface, are used to restore the original properties of the pavement. The problem is that, for a rejuvenator to be successful, it must penetrate the pavement surface. Furthermore, application of a rejuvenator will reduce the skid resistance of the pavement and, besides, rejuvenators have many aromatic compounds that can be harmful for the environment. To solve these problems this paper introduces a new concept in road construction: encapsulated rejuvenators. The basic principle is that when the stress in capsules embedded in the asphalt reaches a certain threshold value, the capsules break and some rejuvenator is released, restoring the original properties of the pavement. This paper will show how to prepare such capsules and how to determine their characteristics. This is one of the first steps towards intelligent pavements.

  20. Quantitative analysis of patients with celiac disease by video capsule endoscopy: A deep learning method.

    Science.gov (United States)

    Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing

    2017-06-01

    Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Current Clinical Indications for Small Bowel Capsule Endoscopy.

    Science.gov (United States)

    Rosa, Bruno; Cotter, José

    2015-01-01

    Small bowel capsule endoscopy is currently the first line diagnostic examination for many diseases affecting the small bowel. This article aims to review and critically address the current indications of small bowel capsule endoscopy in clinical practice. Bibliographic review of relevant and recent papers indexed in PubMed. Small bowel capsule endoscopy enables a non-invasive full-assessment of the small bowel mucosa, with high diagnostic yield even for subtle lesions. In patients with obscure gastrointestinal bleeding, diagnostic yield is higher when performed early after the onset of bleeding. Endoscopic treatment of angioectasias using balloon-assisted enteroscopy may contribute to reduce rebleeding, while the risk of rebleeding in patients with 'negative' small bowel capsule endoscopy is debatable. Cross-sectional imaging may be more accurate than small bowel capsule endoscopy for the diagnosis of large small bowel tumors. The Smooth Protruding Index on Capsule Endoscopy (SPICE score) may help to differentiate submucosal tumors from innocent bulges. Small bowel capsule endoscopy is also a key diagnostic instrument in patients with suspected Crohn's disease and non-diagnostic ileocolonoscopy; it may also influence prognosis and therapeutic management, by determining disease extent and activity in patients with known Crohn's disease. The role of small bowel capsule endoscopy to investigate possible complications in patients with non-responsive coeliac disease is evolving. Small bowel capsule endoscopy is a valuable diagnostic instrument for patients with obscure gastrointestinal bleeding and/or suspected small bowel tumors; it may also be a key examination in patients with suspected Crohn's disease, or patients with known Crohn's disease to fully assess disease extension and activity; finally, it may contribute for the diagnosis of complications of non-responsive coeliac disease.

  2. Solid State Stability of Extemporaneously Prepared Levothyroxine Aliquots and Capsules.

    Science.gov (United States)

    Fortner, Jeff; Salton, Jason; Carlson, Christie; Wheeler, Rich; Cote, Brianna; Rao, Deepa

    2015-01-01

    The purpose of this research was to collect, analyze, and compare stability data for levothyroxine (T4) powder in the anhydrous and pentahydrate form when prepared as an aliquot and in capsules. Two different compounding pharmacies, Central Iowa Compounding and Gateway Medical Pharmacy, used different forms of T4 and aliquot formulations, which were studied to determine the beyond-use date at ±5% or ±10% of labeled strength. T4 was extracted from aliquot and capsule formulations and assessed using reverse-phase high- performance liquid chromatography validated to differentiate between the degraded and original forms of T4. The results indicate that T4 1:100 aliquot formulation prepared with silica gel or Avicel as filler are stable for 120 days at ±10% labeled potency, but at ±5% labeled potency, the silica gel and Avicel aliquot formulations are stable for 45 and 30 days, respectively. The silica gel capsules prepared from fresh aliquot were stable for 120 days at ±10% labeled potency and 90 days at ±5% labeled potency, while the Avicel capsules prepared from fresh aliquot were stable for 180 days at both ±10% and ±5% labeled potency. Avicel capsules prepared from old aliquot (120 days) and fresh aliquot (1 day) were also compared for stability. The old aliquot Avicel capsules were stable for 14 days at ±5% labeled potency and 150 days at ±10% labeled potency, while new aliquot Avicel capsules were stable for 180 days at both ±10% and ±5% labeled potency. Based on our data, there can be significant variation in the beyond-use dates assigned to T4 capsules based on the diluents used for aliquots, the final capsule formulations, and the potency standards applied. These results also indicate that pharmacists must exercise caution when using older aliquots and may have to assign shorter beyond-use dates.

  3. The influence of size on the toxicity of an encapsulated pesticide: a comparison of micron- and nano-sized capsules.

    Science.gov (United States)

    Meredith, Alicea N; Harper, Bryan; Harper, Stacey L

    2016-01-01

    response of the entrapped λ-Cy, but the presence or absence of the capsules does. Testing across other encapsulated products is needed to determine if size does not have influence on toxicity regardless of encapsulation technology.

  4. Researches on Magnetic Localization for Detecting Capsule in Gastrointestinal Tract

    Institute of Scientific and Technical Information of China (English)

    HE Wen-hui; YAN Guo-zheng; GUO Xu-dong; WANG Kun-dong

    2007-01-01

    Recently, the capsule detection for examination of gastrointestinal (GI) tract became a novel noninvasive system, but it was still a problem for capsule's location.This paper examined various technologies used for measuring position based on magnetic method of the capsule in GI tract, while some new methods were investigated and their efficiency and complexity were analyzed.The results show that the radio frequency location is only practicable, but the tri-coil stimulating magnetic method and magnetic marker method can help to acquire a high precise, simplified, efficient and localized device.

  5. Characterisation of two AGATA asymmetric high purity germanium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Colosimo, S.J., E-mail: sjc@ns.ph.liv.ac.uk [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Nolan, P.J. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Unsworth, C. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2015-02-11

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array.

  6. Isolation of Klebsiella terrigena from human feces: biochemical reactions, capsule types, and antibiotic sensitivity.

    Science.gov (United States)

    Podschun, R

    1991-04-01

    Colonization of the human intestinal tract by a newly proposed species, K. terrigena, was investigated. 5377 different stool specimens from healthy persons (food handlers) yielded 50 isolates (0.9%). Biochemically, low frequencies in the degradation of urea, dulcitol, and utilization of citrate at 37 degrees C were found when compared to K. pneumoniae. At 30 degrees C, urea hydrolysis was observed twice as often as at 37 degrees C. Apart from ampicillin, K. terrigena was susceptible to 12 other antimicrobial drugs tested. Multiple drug resistance was rare, few isolates being resistant against 2-4 antibiotic agents. Capsule typing revealed 30 different serotypes, K 70 and K 14 were the most frequent. Six strains expressed capsule types K 2 and K 5, which have been reported to be associated with virulence in K. pneumoniae. A possible pathogenic role of K. terrigena is discussed.

  7. A Real-Time Localization System for an Endoscopic Capsule Using Magnetic Sensors

    Directory of Open Access Journals (Sweden)

    Duc Minh Pham

    2014-11-01

    Full Text Available Magnetic sensing technology offers an attractive alternative for in vivo tracking with much better performance than RF and ultrasound technologies. In this paper, an efficient in vivo magnetic tracking system is presented. The proposed system is intended to localize an endoscopic capsule which delivers biomarkers around specific locations of the gastrointestinal (GI tract. For efficiently localizing a magnetic marker inside the capsule, a mathematical model has been developed for the magnetic field around a cylindrical magnet and used with a localization algorithm that provides minimum error and fast computation. The proposed tracking system has much reduced complexity compared to the ones reported in the literature to date. Laboratory tests and in vivo animal trials have demonstrated the suitability of the proposed system for tracking a magnetic marker with expected accuracy.

  8. Fluid extravasation of the articular capsule as a complication of temporomandibular joint pumping and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Kenichi; Watahiki, Ryuichirou; Tamura, Hidetoshi; Ogura, Motoi; Shibuya, Masayuki [Kameda General Hospital, Kamogawa, Chiba (Japan)

    2002-11-01

    This report is a retrospective study of fluid extravasation as a complication of temporomandibular joint pumping and perfusion. Contrast-enhanced 3D-CT of the upper joint compartment was performed for presurgical diagnosis before temporomandibular joint arthroscopic surgery in our hospital from 1996 to 2000. From these cases, 43 joints and 38 patients were selected because they had not improved under conservative treatment during the previous six months. Fluid extravasation of the articular capsule was recognized in 9 joints (20.9%) in 9 patients, 3 males and 6 females. Two of the nine patients had undergone arthroscopic observation before surgery. This test had revealed only thin articular capsule, not a perforation, in any of these cases. The data indicate only extremely tiny perforations or infiltration leakage due to the fluid pressure in the upper joint compartment during pumping or perfusion. Oral and maxillofacial surgeons should be aware of this complication. (author)

  9. High efficiency nanocomposite sorbents for CO2 capture based on amine-functionalized mesoporous capsules

    KAUST Repository

    Qi, Genggeng

    2011-01-01

    A novel high efficiency nanocomposite sorbent for CO2 capture has been developed based on oligomeric amine (polyethylenimine, PEI, and tetraethylenepentamine, TEPA) functionalized mesoporous silica capsules. The newly synthesized sorbents exhibit extraordinary capture capacity up to 7.9 mmol g-1 under simulated flue gas conditions (pre-humidified 10% CO 2). The CO2 capture kinetics were found to be fast and reached 90% of the total capacities within the first few minutes. The effects of the mesoporous capsule features such as particle size and shell thickness on CO2 capture capacity were investigated. Larger particle size, higher interior void volume and thinner mesoporous shell thickness all improved the CO2 capacity of the sorbents. PEI impregnated sorbents showed good reversibility and stability during cyclic adsorption-regeneration tests (50 cycles). © 2011 The Royal Society of Chemistry.

  10. Representing distance, consuming distance

    DEFF Research Database (Denmark)

    Larsen, Gunvor Riber

    to mobility and its social context. Such an understanding can be approached through representations, as distance is being represented in various ways, most noticeably in maps and through the notions of space and Otherness. The question this talk subsequently asks is whether these representations of distance...... are being consumed in the contemporary society, in the same way as places, media, cultures and status are being consumed (Urry 1995, Featherstone 2007). An exploration of distance and its representations through contemporary consumption theory could expose what role distance plays in forming...... are present in theoretical and empirical elaborations on mobility, but these remain largely implicit and unchallenged (Bauman 1998). This talk will endeavour to unmask distance as a theoretical entity by exploring ways in which distance can be understood and by discussing distance through its representations...

  11. Efficacy of oxitard capsules in the treatment of oral submucous fibrosis

    Directory of Open Access Journals (Sweden)

    Santosh Patil

    2015-01-01

    Full Text Available Aim: Oral submucous fibrosis (OSMF is a high-risk premalignant condition predominantly seen in the Indian subcontinent. The aim of the present study was to evaluate the efficacy of oxitard capsules in the management of OSMF. Materials and Methods: Total of 120 subjects with clinico-pathologically diagnosed OSMF were included in the study and divided equally in 2 groups; Group A (oxitard group and Group B (placebo group. Group A was administered 2 oxitard capsules twice daily and Group B was given placebo tablets twice daily, for 3 months. Evaluation for different clinical parameters was done at regular intervals and data was analyzed using the Student′s paired t test and Chi-square test. P < 0.001 was considered to be statistically significant. Results: Clinical improvements in mouth-opening and tongue protrusion were significant in the Group A (P < 0.001. Subjective symptoms of burning sensation (P = 0.0001, pain associated with the lesion (P = 0.000, difficulty in swallowing (P = 0.0003 and speech (P = 0.0005 also significantly improved in the Group A. There was a mild to moderate decrease in the size of the lesion. Conclusion: Though there is no definitive treatment for the condition; however, oxitard capsules can bring about significant clinical improvements in the symptoms like mouth-opening, tongue protrusion, burning sensation, difficulty in swallowing and speech and pain associated with the lesion, thereby improving the quality of life of the affected individuals.

  12. 77 FR 66621 - Draft Guidance for Industry on Bioequivalence Recommendation for Lenalidomide Capsules; Availability

    Science.gov (United States)

    2012-11-06

    ... for Lenalidomide Capsules; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice... lenalidomide capsules. The draft guidance is a revised version of a previously published draft guidance on the... availability of revised draft BE recommendations for lenalidomide capsules. Revlimid (lenalidomide capsules...

  13. Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.

    Science.gov (United States)

    Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi

    2014-08-07

    Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.

  14. Emerging methods for the fabrication of polymer capsules.

    Science.gov (United States)

    Cui, Jiwei; van Koeverden, Martin P; Müllner, Markus; Kempe, Kristian; Caruso, Frank

    2014-05-01

    Hollow polymer capsules are attracting increasing research interest due to their potential application as drug delivery vectors, sensors, biomimetic nano- or multi-compartment reactors and catalysts. Thus, significant effort has been directed toward tuning their size, composition, morphology, and functionality to further their application. In this review, we provide an overview of emerging techniques for the fabrication of polymer capsules, encompassing: self-assembly, layer-by-layer assembly, single-step polymer adsorption, bio-inspired assembly, surface polymerization, and ultrasound assembly. These techniques can be applied to prepare polymer capsules with diverse functionality and physicochemical properties, which may fulfill specific requirements in various areas. In addition, we critically evaluate the challenges associated with the application of polymer capsules in drug delivery systems. © 2013.

  15. [Acute caffeine intoxication after intake of 'herbal energy capsules'

    NARCIS (Netherlands)

    Kromhout, H.E.; Landstra, A.M.; Luin, M. van; Setten, P.A. van

    2008-01-01

    Two males, 15 and 17 years old respectively, presented at the Emergency Department complaining of cramping abdominal pain, nausea and vomiting after ingestion of energy capsules. Physical examination revealed sinus tachycardia and slight abdominal pain. Laboratory examination showed substantial

  16. [Acute caffeine intoxication after intake of 'herbal energy capsules'

    NARCIS (Netherlands)

    Kromhout, H.E.; Landstra, A.M.; Luin, M. van; Setten, P.A. van

    2008-01-01

    Two males, 15 and 17 years old respectively, presented at the Emergency Department complaining of cramping abdominal pain, nausea and vomiting after ingestion of energy capsules. Physical examination revealed sinus tachycardia and slight abdominal pain. Laboratory examination showed substantial hypo

  17. Wireless capsule video endoscopy:Three years of experience

    Institute of Scientific and Technical Information of China (English)

    Rami Eliakim

    2004-01-01

    AIM: To review and summerize the current literatue regarding M2A wireless capsule endoscopy.METHODS: Peer reviewed publications regarding the use of capsule endoscopy as well as our personal experience were reviewed.RESULTS: Review of the literature dearly showed that capsule endoscopy was superior to enteroscopy, small bowel follow through and computerized tomography in patients with obscure gastrointestinal bleeding, iron deficiency anemia,or suspected Crohn′s disease. It was very sensitive for the diagnosis of small bowel tumors and for survailance of small bowel pathology in patients with Gardner syndrome or familial adenomatous polyposis syndrome. Its role in celiac disease and in patients with known Crohn′s disease was currently being investigated.CONCLUSION: Capsule video endoscopy is a superior and more sensitive diagnostic tool than barium follow through,enteroscopy and entero- CT in establishing the diagnosis of many small bowel pathologies.

  18. Capsule endoscopy of the future: What's on the horizon?

    Science.gov (United States)

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-10-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years.

  19. Inhibition of phage infection in capsule-producing Streptococcus ...

    African Journals Online (AJOL)

    SERVER

    2007-10-04

    Oct 4, 2007 ... Acid production by capsule-producing Streptococcus thermophilus was inhibited less ... lactic acid bacteria (LAB) are of similar size to fat globules ..... Characterization of new virulent phage (MLC-A) of Lactobacillus paracasei.

  20. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule.

  1. Representativity of TMA studies.

    Science.gov (United States)

    Sauter, Guido

    2010-01-01

    The smaller the portion of a tumor sample that is analyzed becomes, the higher is the risk of missing important histological or molecular features that might be present only in a subset of tumor cells. Many researchers have, therefore, suggested using larger tissue cores or multiple cores from the same donor tissue to enhance the representativity of TMA studies. However, numerous studies comparing the results of TMA studies with the findings from conventional large sections have shown that all well-established associations between molecular markers and tumor phenotype or patient prognosis can be reproduced with TMAs even if only one single 0.6 mm tissue spot is analyzed. Moreover, the TMA technology has proven to be superior to large section analysis in finding new clinically relevant associations. The high number of samples that are typically included in TMA studies, and the unprecedented degree of standardization during TMA experiments and analysis often give TMA studies an edge over traditional large-section studies.

  2. Determining the Optimum Font Size for Braille on Capsule Paper

    OpenAIRE

    Watanabe, Tetsuya

    2014-01-01

    Braille fonts allow us to easily make braille labels on capsule paper. For legibility, fonts should be printed at optimum sizes. To find the optimum sizes for Japanese braille fonts, we conducted an experiment in which a Japanese braille font was printed at various sizes on capsule paper and read and rated by young braille users. The results show that braille printed at 17 and 18 point sizes were read faster and evaluated higher than those printed at smaller or bigger sizes.

  3. Granular computing in mosaicing of images from capsule endoscopy

    OpenAIRE

    Maciura, Lukasz; Bazan, Jan G.

    2015-01-01

    This article introduces methods for modeling compound granules used in algorithms which could successfully construct a mosaic from the images coming from an endoscope capsule. In order to apply the algorithm, combined images must have a common area where the correspondence of points is determined. That allows to determine the transformation parameters to compensate movement of the capsule that occurs between moments when the mosaic images were acquired. The developed algorithm for images from...

  4. Study of Contact Melting Inside Isothermally Heated Vertical Cylindrical Capsules

    Institute of Scientific and Technical Information of China (English)

    ChenWenzhen; ChengShangmo; 等

    1993-01-01

    Close-contact melting processes of phase change material(PCM) inside vertical cylindrical capsule are studied.PCM are heated bhy the capsule isothermalyy at the bottom and side.The theoretical formulas of the melting rate and thickness of liquid layer during the heat transfer process are obtained by analysis,which are convenient for engineering predictions.Finally,the factors that affect melting are discussed.and conclusions are drawn.

  5. Modeling gated neutron images of THD capsules

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Douglas Carl [Los Alamos National Laboratory; Grim, Gary P [Los Alamos National Laboratory; Tregillis, Ian L [Los Alamos National Laboratory; Wilke, Mark D [Los Alamos National Laboratory; Morgan, George L [Los Alamos National Laboratory; Loomis, Eric N [Los Alamos National Laboratory; Wilde, Carl H [Los Alamos National Laboratory; Oertel, John A [Los Alamos National Laboratory; Fatherley, Valerie E [Los Alamos National Laboratory; Clark, David D [Los Alamos National Laboratory; Schmitt, Mark J [Los Alamos National Laboratory; Merrill, Frank E [Los Alamos National Laboratory; Wang, Tai - Sen F [Los Alamos National Laboratory; Danly, Christopher R [Los Alamos National Laboratory; Batha, Steven H [Los Alamos National Laboratory; Patel, M [LLNL; Sepke, S [LLNL; Hatarik, R [LLNL; Fittinghoff, D [LLNL; Bower, D [LLNL; Marinak, M [LLNL; Munro, D [LLNL; Moran, M [LLNL; Hilko, R [NSTEC; Frank, M [LLNL; Buckles, R [NSTEC

    2010-01-01

    Time gating a neutron detector 28m from a NIF implosion can produce images at different energies. The brighter image near 14 MeV reflects the size and symmetry of the capsule 'hot spot'. Scattered neutrons, {approx}9.5-13 MeV, reflect the size and symmetry of colder, denser fuel, but with only {approx}1-7% of the neutrons. The gated detector records both the scattered neutron image, and, to a good approximation, an attenuated copy of the primary image left by scintillator decay. By modeling the imaging system the energy band for the scattered neutron image (10-12 MeV) can be chosen, trading off the decayed primary image and the decrease of scattered image brightness with energy. Modeling light decay from EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A leads to a preference from BCF99-55 for the first NIF detector, but DPAC 30 and Liquid A would be preferred if incorporated into a system. Measurement of the delayed light from the NIF scintillator using implosions at the Omega laser shows BCF99-55 to be a good choice for down-scattered imaging at 28m.

  6. Internal capsule stroke in the common marmoset.

    Science.gov (United States)

    Puentes, S; Kaido, T; Hanakawa, T; Ichinohe, N; Otsuki, T; Seki, K

    2015-01-22

    White matter (WM) impairment and motor deficit after stroke are directly related. However, WM injury mechanisms and their relation to motor disturbances are still poorly understood. In humans, the anterior choroidal artery (AChA) irrigates the internal capsule (IC), and stroke to this region can induce isolated motor impairment. The goal of this study was to analyze whether AChA occlusion can injure the IC in the marmoset monkey. The vascular distribution of the marmoset brain was examined by colored latex perfusion and revealed high resemblance to the human brain anatomy. Next, a new approach to electrocoagulate the AChA was developed and chronic experiments showed infarction compromising the IC on magnetic resonance imaging (MRI) scanning (day 4) and histology (day 11). Behavioral analysis was performed using a neurologic score previously developed and our own scoring method. Marmosets showed a decreased score that was still evident at day 10 after AChA electrocoagulation. We developed a new approach able to induce damage to the marmoset IC that may be useful for the detailed study of WM impairment and behavioral changes after stroke in the nonhuman primate.

  7. Capsule Endoscopy for Portal Hypertensive Enteropathy

    Directory of Open Access Journals (Sweden)

    Seong Ran Jeon

    2016-01-01

    Full Text Available Portal hypertensive enteropathy (PHE is a mucosal abnormality of the small bowel that is observed in patients with portal hypertension (PH and can lead to gastrointestinal bleeding and anemia. The pathogenesis is still not completely understood. The introduction of new endoscopic methods, including capsule endoscopy (CE or balloon-assisted enteroscopy, has increased the detection of these abnormalities. CE can also serve as a road map for deciding subsequent interventions and evaluating the treatment effect. The prevalence of PHE is reportedly 40–70% in patients with PH. Endoscopic findings can be roughly divided into vascular and nonvascular lesions such as inflammatory-like lesions. Traditionally, PHE-associated factors include large esophageal varices, portal hypertensive gastropathy or colopathy, Child-Turcotte-Pugh class B or C, a history of variceal treatment, and acute gastrointestinal bleeding. More recently, on using scoring systems, a high computed tomography or transient elastography score was reportedly PHE-related factors. However, the prevalence of PHE and its related associated factors remain controversial. The management of PHE has not yet been standardized. It should be individualized according to each patient’s situation, the availability of therapy, and each institutional expertise.

  8. Electromagnetic wave propagation of wireless capsule endoscopy in human body

    Institute of Scientific and Technical Information of China (English)

    LIM; Eng-Gee; 王炤; 陈瑾慧; TILLO; Tammam; MAN; Ka-lok

    2013-01-01

    Wireless capsule endoscopy(WCE) is a promising technique which has overcome some limitations of traditional diagnosing tools, such as the comfortlessness of the cables and the inability of examining small intestine section. However, this technique is still far from mature and asks for the feasible improvements. For example, the relatively low transmission data rate and the absence of the real-time localization information of the capsule are all important issues. The studies of them rely on the understanding of the electromagnetic wave propagation in human body. Investigation of performance of WCE communication system was carried out by studying electromagnetic(EM) wave propagation of the wireless capsule endoscopy transmission channel. Starting with a pair of antennas working in a human body mimic environment, the signal transmissions and attenuations were examined. The relationship between the signal attenuation and the capsule(transmitter) position, and direction was also evaluated. These results provide important information for real-time localization of the capsule. Moreover, the pair of antennas and the human body were treated as a transmission channel, on which the binary amplitude shift keying(BASK) modulation scheme was used. The relationship between the modulation scheme, data rate and bit error rate was also determined in the case of BASK. With the obtained studies, it make possible to provide valuable information for further studies on the selection of the modulation scheme and the real-time localization of the capsules.

  9. Bushen Yisui Capsule ameliorates axonal injury in experimental autoimmune encephalomyelitis

    Institute of Scientific and Technical Information of China (English)

    Ling Fang; Lei Wang; Qi Zheng; Tao Yang; Hui Zhao; Qiuxia Zhang; Kangning Li; Li Zhou; Haiyang Gong; Yongping Fan

    2013-01-01

    A preliminary clinical study by our group demonstrated Bushen Yisui Capsule (formerly cal ed Er-huang Formula) in combination with conventional therapy is an effective prescription for the treat-ment of multiple sclerosis. However, its effect on axonal injury during early multiple sclerosis re-mains unclear. In this study, a MOG 35-55-immunized C57BL/6 mouse model of experimental au-toimmune encephalomyelitis was intragastrical y administered Bushen Yisui Capsule. The results showed that Bushen Yisui Capsule effectively improved clinical symptoms and neurological function of experimental autoimmune encephalomyelitis. In addition, amyloid precursor protein expression was down-regulated and microtubule-associated protein 2 was up-regulated. Experimental findings indicate that the disease-preventive mechanism of Bushen Yisui Capsule in experimental autoim-mune encephalomyelitis was mediated by amelioration of axonal damage and promotion of rege-neration. But the effects of the high-dose Bushen Yisui Capsule group was not better than that of the medium-dose and low-dose Bushen Yisui Capsule group in preventing neurological dysfunction.

  10. Pentagonal shaped microstrip patch antenna in wireless capsule endoscopy system

    Directory of Open Access Journals (Sweden)

    Bondili Kohitha Bai

    2012-01-01

    Full Text Available Wireless capsule endoscopy is a best option for exploring inaccessible areas of small intestine for inspection of gastrointestinal tract. This technique brings less pain compare to conventional endoscopy technique. The wireless endoscopy system comprises of three main modules: an ingestible capsule that is swallowed by the patient, an external control unit and display device for image display. In this paper we proposed pentagonal shape microstrip patch antenna for wireless capsule endoscopy system. Inhibiting characteristics of a single microstrip patch like low gain, light weight, thin thickness and smaller bandwidth, make it more popular. This kind of antenna is aggressive miniaturized to meet the requirements of the wireless capsule endoscope. The simulation results show that the designed Circular Polarization (CP pentagonal shaped microstrip patch antenna gives axial ratio of 0.6023 at 2.38 GHz and CP axial ratio bandwidth of 36MHz with 1.5%. The antenna designed for wireless capsule endoscopy is a proposed one, which may work effectively when compared to other antennas in the capsule.

  11. MALDI-MS-imaging of whole human lens capsule.

    Science.gov (United States)

    Ronci, Maurizio; Sharma, Shiwani; Chataway, Tim; Burdon, Kathryn P; Martin, Sarah; Craig, Jamie E; Voelcker, Nicolas H

    2011-08-05

    The ocular lens capsule is a smooth, transparent basement membrane that encapsulates the lens and is composed of a rigid network of interacting structural proteins and glycosaminoglycans. During cataract surgery, the anterior lens capsule is routinely removed in the form of a circular disk. We considered that the excised capsule could be easily prepared for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry imaging (MALDI-MSI) analysis. MALDI-MSI is a powerful tool to elucidate the spatial distribution of small molecules, peptides, and proteins within tissues. Here, we apply this molecular imaging technique to analyze the freshly excised human lens capsule en face. We demonstrate that novel information about the distribution of proteins by MALDI-MSI can be obtained from this highly compact connective tissue, having no evident histo-morphological characteristics. Trypsin digestion carried out on-tissue is shown to improve MALDI-MSI analysis of human lens capsules and affords high repeatability. Most importantly, MALDI-MSI analysis reveals a concentric distribution pattern of proteins such as apolipoprotein E (ApoE) and collagen IV alpha-1 on the anterior surface of surgically removed lens capsule, which may indicate direct or indirect effects of environmental and mechanical stresses on the human ocular lens.

  12. Levothyroxine soft capsules demonstrate bioequivalent pharmacokinetic exposure with the European reference tablets in healthy volunteers under fasting conditions.

    Science.gov (United States)

    Al-Numani, Dina; Scarsi, Claudia; Ducharme, Murray P

    2016-02-01

    To assess the bioequivalence (BE) potential under fasting conditions between levothyroxine soft capsules and the European reference tablet formulation. Two studies were conducted to assess the BE potential as per European regulations. Study 1 was a two-way crossover BE study comparing a high strength of levothyroxine soft capsules versus levothyroxine tablets (200 μg), while study 2 was a three-way crossover dosage form proportionality study between low, medium, and high strengths of soft capsules. 70 healthy adult subjects participated in the two studies. Each treatment consisted of a 600-μg dose of levothyroxine sodium, administered under fasting conditions. Blood samples were collected for levothyroxine (T4) assay prior to dosing and up to 72 hours post dose. A washout of 35 days separated treatments in each study. Pharmacokinetics was assessed using noncompartmental methods. A total of 61 subjects completed the studies. Baseline-adjusted total T4 ratios (test/reference) and 90% confidence intervals (CIs) between soft capsules and tablets were within 80.00 - 125.00%. Comparison of the three strengths of soft capsules indicated pharmacokinetic equivalence between them (ratios and 90% CIs were contained within 80.00 - 125.00%). Overall, levothyroxine sodium was well tolerated with all products when given as single oral doses of 600 μg, except for 1 serious adverse event of secondary bacteremia reported in study 2, deemed not to be related to treatment. Levothyroxine soft capsules meet BE criteria in terms of systemic exposure when compared to a European reference tablet under fasting conditions in healthy volunteers.

  13. Genetic toxicity assessment of aloe capsule%芦荟软胶囊的遗传毒性评价

    Institute of Scientific and Technical Information of China (English)

    贾玉巧; 白国胜; 王宇梅; 田俊丽

    2011-01-01

    目的:探讨某品牌芦荟软胶囊的遗传毒性.方法:使用小鼠经口急性毒性试验、小鼠骨髓嗜多染红细胞微核试验、鼠伤寒沙门氏菌回复突变(Ames)试验、和小鼠精子畸形试验对芦荟软胶囊的遗传毒性进行评价.结果:芦荟软胶囊对小鼠的经口急性毒性LD50大于20 ml/kgBW(最大灌胃容量),属实际无毒物质.微核试验、Ames试验和精子畸形试验结果均为阴性.结论:在本次试验条件下,该品牌芦荟软胶囊未显示有遗传毒性作用.%Objective: To study the genetic toxicity of aloe capsule. Methods: A cute toxicity test of mice, micronucleus test of bone marrow PCE cell in mice, Ames test,sperm shape abnormality test of mice. Results: The aloe capsule was a substance with no toxicity according to the acute toxicity. The results of genetic toxicity test were all negative, including micronucleus test, Ames test and sperm shape abnormality test. Conclusion: The aloe capsule has no genetic toxicity in this test.

  14. 克肝膠囊对CCI4慢性肝损伤大鼠的影响%Influence of KeGan Capsule to Mice with CCI4 Chronic Hepatic Injury

    Institute of Scientific and Technical Information of China (English)

    徐玉芳

    2004-01-01

    Objective To study the action of KeGan capsule to resist injury of hepatic cells and fibrosis of liver. Methods Replicate model of chronic hepatic injury with CCl4, at the beginning of which KeGan capsule was applied; finishing experiment, respectively tested the level of liver function, TP,ALB, A/G, L - hydroxyproline and liver index and do pathologic examination to liver. Results KeGan capsule can obviously reduce the degree of fibrosis of liver and the level of L - hydroxyproline, improve the liver function. The histological examination showed that capsule has the action of protecting hepatic cells from injury and resisting fibrosis of liver either. Conclusion For KeGan capsule has the action of resisting injury of liver cells and fibrosis of liver, it' s hoped to be applied in precaution and treatnent of fibrosis of liver.

  15. Earthworm symbiont Verminephrobacter eiseniae mediates natural transformation within the host egg capsules using type IV pili

    Directory of Open Access Journals (Sweden)

    SEANA Kelyn DAVIDSON

    2014-10-01

    Full Text Available The dense microbial communities commonly associated with plants and animals should offer many opportunities for horizontal gene transfer (HGT through described mechanisms of DNA exchange including natural transformation. However, studies of the significance of natural transformation have focused primarily on pathogens. The study presented here demonstrates highly efficient DNA exchange by natural transformation in a common symbiont of earthworms. The obligate bacterial symbiont Verminephrobacter eiseniae is a member of a microbial consortium of the earthworm Eisenia fetida that is transmitted into the egg capsules to colonize the embryonic worms. In the study presented here, by testing for transformants under different conditions in culture, we demonstrate that V. eiseniae can incorporate free DNA from the environment, that competency is regulated by environmental factors, and that it is sequence specific. Mutations in the type IV pili of V. eiseniae resulted in loss of DNA uptake, implicating the type IV pilus (TFP apparatus in DNA uptake. Furthermore, injection of DNA carrying antibiotic-resistance genes into egg capsules resulted in transformants within the capsule, demonstrating the relevance of DNA uptake within the earthworm system. The ability to take up species-specific DNA from the environment may explain the maintenance of the relatively large, intact genome of this long-associated obligate symbiont, and provides a mechanism for acquisition of foreign genes within the earthworm system.

  16. Geometric estimation of intestinal contraction for motion tracking of video capsule endoscope

    Science.gov (United States)

    Mi, Liang; Bao, Guanqun; Pahlavan, Kaveh

    2014-03-01

    Wireless video capsule endoscope (VCE) provides a noninvasive method to examine the entire gastrointestinal (GI) tract, especially small intestine, where other endoscopic instruments can barely reach. VCE is able to continuously provide clear pictures in short fixed intervals, and as such researchers have attempted to use image processing methods to track the video capsule in order to locate the abnormalities inside the GI tract. To correctly estimate the speed of the motion of the endoscope capsule, the radius of the intestinal track must be known a priori. Physiological factors such as intestinal contraction, however, dynamically change the radius of the small intestine, which could bring large errors in speed estimation. In this paper, we are aiming to estimate the radius of the contracted intestinal track. First a geometric model is presented for estimating the radius of small intestine based on the black hole on endoscopic images. To validate our proposed model, a 3-dimentional virtual testbed that emulates the intestinal contraction is then introduced in details. After measuring the size of the black holes on the test images, we used our model to esimate the radius of the contracted intestinal track. Comparision between analytical results and the emulation model parameters has verified that our proposed method could preciously estimate the radius of the contracted small intestine based on endoscopic images.

  17. Wireless power and data transmission strategies for next-generation capsule endoscopes

    Science.gov (United States)

    Puers, R.; Carta, R.; Thoné, J.

    2011-05-01

    Capsular endoscopy is becoming increasingly popular as an alternative to traditional gastro-intestinal (GI) examination techniques. However, the breakthrough of these devices is hindered by the limited amount of power that can be stored in a tiny pill. Most commercial devices use two watch batteries that can only provide an average power of 25 mW for about 6 h, certainly not sufficient for advanced robotic features. A dedicated inductive powering system, operating at 1 MHz to limit the human body absorption, has been developed which was proven to support the transfer of over 300 mW. The system relies on a condensed set of orthogonal ferrite coils, embedded in the capsule, and an external unit based on a Helmholtz coil driven by a class E amplifier. Control data can be sent through the inductive link by modulating the power carrier, whereas a dedicated high data rate RF link is used to transfer the images from the capsule to the base station. Besides evaluating the compatibility with radio transmission, several demonstrators were assembled combining the wireless powering system with various locomotion strategies and LED illumination. This paper describes the design and implementation of the inductive powering system, its combination with data transmission techniques and the testing activity with other capsule-dedicated modules.

  18. Entry, Descent, and Landing Operations Analysis for the Stardust Entry Capsule

    Science.gov (United States)

    Desai, Prasun N.; Lyons, Dan T.; Tooley, Jeff; Kangas, Julie

    2008-01-01

    On the morning of January 15, 2006, the Stardust capsule successfully landed at the Utah Test and Training range in northwest Utah returning cometary samples from the comet Wild-2. An overview of the entry, descent, and landing (EDL) trajectory analysis that was performed for targeting during the mission operations phase upon final approach to Earth is described. The final orbit determination solution produced an inertial entry flight-path angle of -8.21 deg (the desired nominal value) with a 3-sigma uncertainty of +/-0.0017 deg (2% of the requirement). The navigation and EDL operations effort accurately delivered the entry capsule to the desired landing site. The final landing location was 8.1 km from the target, which was well within the allowable landing area. Overall, the Earth approach operation procedures worked well and there were no issues (logistically or performance based) that arose. As a result, the process of targeting a capsule from an interplanetary trajectory and accurately landing it on Earth was successfully demonstrated.

  19. Capsule Endoscopy for Crohn’s Disease: Current Status of Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Dong-Hoon Yang

    2016-01-01

    Full Text Available Crohn’s disease (CD is an idiopathic inflammatory bowel disease involving the small and/or large intestine. More than 50% of Western CD patients and up to 88% of Asian CD patients may have small intestinal involvement. Video capsule endoscopy (VCE has a higher diagnostic yield than small bowel barium radiography and computed tomography enterography for the detection of small intestinal involvement of CD. VCE also provides diagnostic yields comparable to magnetic resonance- (MR- based enterography or enteroclysis and may have several advantages over MR-based tests for the detection of early small intestinal lesions. Several studies have suggested the use of VCE-based disease activity scoring systems to evaluate small intestinal mucosal disease activity, although their clinical relevance needs to be further studied. A possible indication for VCE is recurrence monitoring after complete surgical excision of CD-involved segments but its usefulness and efficacy compared with conventional endoscopy should be evaluated. The capsule retention rate ranges from 0 to 5.4% in suspected CD patients and from 0 to 13.2% in established CD patients. If VCE is necessary, significant small bowel stricture should be ruled out before VCE by performing a patency capsule study and/or small bowel radiological study in suspected or established CD patients.

  20. Entry, Descent, and Landing Operations Analysis for the Genesis Entry Capsule

    Science.gov (United States)

    Desai, Prasun N.; Lyons, Daniel T.

    2007-01-01

    On September 8, 2004, the Genesis spacecraft returned to Earth after spending 29 months about the sun-Earth libration point (L1) collecting solar wind particles. Four hours prior to Earth arrival, the sample return capsule containing the samples was released for entry and subsequent landing at the Utah Test and Training Range. This paper provides an overview of the entry, descent, and landing trajectory analysis that was performed during the mission operations phase leading up to final approach to Earth. The final orbit determination solution produced an inertial entry flight-path angle of -8.002 deg (which was the desired nominal value) with a 3-sigma error of +/-0.0274 deg (a third of the requirement). The operations effort accurately delivered the entry capsule to the desired landing site. The final landing location was 8.3 km from the target, and was well within the allowable landing area. Overall, the Earth approach operation procedures worked well and there were no issues (logistically or performance based) that arose. As a result, the process of targeting a capsule from deep space and accurately landing it on Earth was successfully demonstrated.

  1. A batch fabricated capacitive pressure sensor with an integrated Guyton capsule for interstitial fluid pressure measurement

    Science.gov (United States)

    Maleki, Teimour; Fogle, Benjamin; Ziaie, Babak

    2011-05-01

    In this paper, we present the design, fabrication and test of a batch fabricated capacitive pressure sensor with an integrated Guyton capsule for interstitial fluid pressure measurement. The sensor is composed of 12 µm thick single crystalline silicon membrane and a 3 µm gap, hermetically sealed through silicon-glass anodic bonding. A novel batch scale method for creating electrical feed-throughs inside the sealed capacitor chamber is developed. The Guyton capsule consists of an array of 10 µm diameter access holes etched onto a silicon back-plate separated from the silicon sensing membrane by a gap of 5 µm. The presence of the Guyton capsule (i.e. plates with access holes plus the gap separating them from the sensing membrane) allows for the ingress of interstitial fluid inside the 5 µm gap following the implantation, thus, providing an accurate measurement of interstitial fluid pressure. The fabricated sensor is 3 × 2 × 0.42 mm3 in dimensions and has a maximum sensitivity of 10 fF mmHg-1.

  2. Feasibility study of Tethered Capsule Endomicroscopy (TCE) deployment in the small intestine (Conference Presentation)

    Science.gov (United States)

    Otuya, David O.; Verma, Yogesh; Dong, Jing; Gora, Michalina J.; Tearney, Guillermo J.

    2017-02-01

    Environmental enteric dysfunction (EED) is a poorly understood disease of the small intestine that causes nutrient malabsorption in children, predominantly from low and middle income countries. The clinical importance of EED is neurological and growth stunting that remains as the child grows into adulthood. Tethered capsule endomicroscopy (TCE) has the potential to improve the understanding of EED and could be used to determine the effectiveness of EED interventions. TCE in the adult esophagus and the duodenum has been demonstrated for Barrett`s esophagus and celiac disease diagnosis, respectively. While adult subjects can independently swallow these capsules, it is likely that infants will not, and, as a result, new strategies for introducing these devices in young children aged 0.5-2 years need to be investigated. Our first approach will be to introduce the TCE devices in infants under the aid of endoscopic guidance. To determine the most effective method, we have tested endoscopic approaches for introducing TCE devices into the small intestine of living swine. These methods will be compared and contrasted to discuss the most effective means for endoscopic tethered capsule introduction into the small intestine.

  3. Thin Shell Model for NIF capsule stagnation studies

    Science.gov (United States)

    Hammer, J. H.; Buchoff, M.; Brandon, S.; Field, J. E.; Gaffney, J.; Kritcher, A.; Nora, R. C.; Peterson, J. L.; Spears, B.; Springer, P. T.

    2015-11-01

    We adapt the thin shell model of Ott et al. to asymmetric ICF capsule implosions on NIF. Through much of an implosion, the shell aspect ratio is large so the thin shell approximation is well satisfied. Asymmetric pressure drive is applied using an analytic form for ablation pressure as a function of the x-ray flux, as well as time-dependent 3D drive asymmetry from hohlraum calculations. Since deviations from a sphere are small through peak velocity, we linearize the equations, decompose them by spherical harmonics and solve ODE's for the coefficients. The model gives the shell position, velocity and areal mass variations at the time of peak velocity, near 250 microns radius. The variables are used to initialize 3D rad-hydro calculations with the HYDRA and ARES codes. At link time the cold fuel shell and ablator are each characterized by a density, adiabat and mass. The thickness, position and velocity of each point are taken from the thin shell model. The interior of the shell is filled with a uniform gas density and temperature consistent with the 3/2PV energy found from 1D rad-hydro calculations. 3D linked simulations compare favorably with integrated simulations of the entire implosion. Through generating synthetic diagnostic data, the model offers a method for quickly testing hypothetical sources of asymmetry and comparing with experiment. Prepared by LLNL under Contract DE-AC52-07NA27344.

  4. High Performance Capsule Implosions on the Omega Laser Facility with Rugby Hohlraums

    Science.gov (United States)

    Robey, Harry F.

    2009-11-01

    Rugby-shaped hohlraums have been proposed as a method for x-ray drive enhancement for indirectly-driven capsule implosions [1]. This concept has recently been tested in a series of shots on the OMEGA laser facility at the Laboratory for Laser Energetics at the University of Rochester. In this talk, experimental results are presented comparing the performance of D2-filled capsules between standard cylindrical Au hohlraums and rugby-shaped hohlraums. Not only did the rugby hohlraums demonstrate 18% more x-ray drive energy as compared with the cylinders, but the high-performance design of these implosions (both cylinder and rugby) also provided 20X more DD neutrons than any previous indirectly-driven campaign on Omega (and 3X more than ever achieved on Nova implosions driven with nearly twice the laser energy). This increase in performance enables, for the first time, a measurement of the neutron burn history of an indirectly-driven implosion. Previous DD neutron yields had been too low to register this key measurement of capsule performance and the effects of dynamic mix. A wealth of additional data on the fuel areal density from the suite of charged particle diagnostics was obtained on a subset of the shots that used D^3He rather than D2 fuel. Comparisons of the experimental results with numerical simulations are shown to be in excellent agreement. The design techniques employed in this campaign, e.g., smaller NIF-like laser entrance holes and hohlraum case-to-capsule ratios, provide added confidence in the pursuit of ignition on the National Ignition Facility. [4pt] [1] P. Amendt, C. Cerjan, D. E. Hinkel, J. L. Milovich, H.-S. Park, and H. F. Robey, ``Rugby-like hohlraum experimental designs for demonstrating x-ray drive enhancement'', Phys. Plasmas 15, 012702 (2008).

  5. High performance capsule implosions on the OMEGA Laser facility with rugby hohlraumsa)

    Science.gov (United States)

    Robey, H. F.; Amendt, P.; Park, H.-S.; Town, R. P. J.; Milovich, J. L.; Döppner, T.; Hinkel, D. E.; Wallace, R.; Sorce, C.; Strozzi, D. J.; Philippe, F.; Casner, A.; Caillaud, T.; Landoas, O.; Liberatore, S.; Monteil, M.-C.; Séguin, F.; Rosenberg, M.; Li, C. K.; Petrasso, R.; Glebov, V.; Stoeckl, C.; Nikroo, A.; Giraldez, E.

    2010-05-01

    Rugby-shaped hohlraums have been proposed as a method for x-ray drive enhancement for indirectly driven capsule implosions. This concept has recently been tested in a series of shots on the OMEGA laser facility [T. R. Boehly, D. L. Brown, R. S. Craxton et al., Opt. Commun. 133, 495 (1997)]. In this paper, experimental results are presented comparing the performance of D2-filled capsules between standard cylindrical Au hohlraums and rugby-shaped hohlraums. The rugby hohlraums demonstrated 18% more x-ray drive energy as compared with the cylinders, and the high-performance design of these implosions (both cylinder and rugby) also provided ≈20× more deuterium (DD) neutrons than any previous indirectly driven campaign on OMEGA and ≈3× more than ever achieved on NOVA [E. M. Campbell, Laser Part. Beams 9, 209 (1991)] implosions driven with nearly twice the laser energy. This increase in performance enables, for the first time, a measurement of the neutron burn history and imaging of the neutron core shapes in an indirectly driven implosion. Previous DD neutron yields had been too low to register this key measurement of capsule performance and the effects of dynamic mix. A wealth of additional data on the fuel areal density from the suite of charged particle diagnostics was obtained on a subset of the shots that used D H3e rather than D2 fuel. Comparisons of the experimental results with numerical simulations are shown to be in very good agreement. The design techniques employed in this campaign, e.g., smaller laser entrance holes and hohlraum case-to-capsule ratios, provide added confidence in the pursuit of ignition on the National Ignition Facility [J. D. Lindl, P. Amendt, R. L. Berger et al., Phys. Plasmas 11, 339 (2004)].

  6. Disassembly of the fusion-1 capsule after irradiation in the BOR-60 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H. [Argonne National Lab., IL (United States); Kazakov, V.A.; Chakin, V.P. [and others

    1997-04-01

    A U.S./Russia (RF) collaborative irradiation experiment, Fusion-1, was completed in June 1996 after reaching a peak exposure of {approx}17 dpa in the BOR-60 fast reactor at the Research Institute of Atomic Reactors (RIAR) in Russia. The specimens were vanadium alloys, mainly of recent heats from both countries. In this reporting period, the capsule was disassembled at the RIAR hot cells and all test specimens were successfully retrieved. For the disassembly, an innovative method of using a heated diffusion oil to melt and separate the lithium bond from the test specimens was adopted. This method proved highly successful.

  7. Chemo-physical properties of renal capsules under ultraviolet-c exposure

    Energy Technology Data Exchange (ETDEWEB)

    Baghapour, Sh.; Parvin, P., E-mail: parvin@aut.ac.ir; Mokhtari, S. [Department of Physics, Amirkabir University of Technology, P.O.Box 15875-4413 Tehran (Iran, Islamic Republic of); Reyhani, A.; Mortazavi, S. Z. [Department of Physics, Imam Khomeini International University, P.O.Box 34149-16818 Qazvin (Iran, Islamic Republic of); Amjadi, A. [Department of Physics, Sharif University of Technology, P.O.Box 11365-9567, Tehran (Iran, Islamic Republic of)

    2014-08-07

    The renal capsule tissue of lamb was irradiated with ultraviolet-C light and the treated samples were analyzed by uniaxial tensile test, dynamic mechanical analysis, attenuated total reflectance Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy and contact angle measurements. It was shown that the skin cross-linking is dominant in low doses in accordance with the contact angle assessment. Conversely, the strong bulk degradation takes place at high doses. Similarly, the bulk cross-linking affects the mechanical tests as to enhance the stiffness at low doses, whereas strong degradation occurs at high doses that mainly arises from the strong bulk chain scission.

  8. Role of glucose and CcpA in capsule expression and virulence of Streptococcus suis.

    Science.gov (United States)

    Willenborg, J; Fulde, M; de Greeff, A; Rohde, M; Smith, H E; Valentin-Weigand, P; Goethe, R

    2011-06-01

    Streptococcus suis is one of the most important pathogens in pigs and is also an emerging zoonotic agent. After crossing the epithelial barrier, S. suis causes bacteraemia, resulting in meningitis, endocarditis and bronchopneumonia. Since the host environment seems to be an important regulatory component for virulence, we related expression of virulence determinants of S. suis to glucose availability during growth and to the sugar metabolism regulator catabolite control protein A (CcpA). We found that expression of the virulence-associated genes arcB, representing arcABC operon expression, cps2A, representing capsular locus expression, as well as sly, ofs, sao and epf, differed significantly between exponential and early stationary growth of a highly virulent serotype 2 strain. Deletion of ccpA altered the expression of the surface-associated virulence factors arcB, sao and eno, as well as the two currently proven virulence factors in pigs, ofs and cps2A, in early exponential growth. Global expression analysis using a cDNA expression array revealed 259 differentially expressed genes in early exponential growth, of which 141 were more highly expressed in the CcpA mutant strain 10ΔccpA and 118 were expressed to a lower extent. Interestingly, among the latter genes, 18 could be related to capsule and cell wall synthesis. Correspondingly, electron microscopy characterization of strain 10ΔccpA revealed a markedly reduced thickness of the capsule. This phenotype correlated with enhanced binding to porcine plasma proteins and a reduced resistance to killing by porcine neutrophils. Taken together, our data demonstrate that CcpA has a significant effect on the capsule synthesis and virulence properties of S. suis.

  9. Psychosocial working conditions and self-reported health in a representative sample of wage-earners: a test of the different hypotheses of the Demand-Control-Support-Model.

    Science.gov (United States)

    Vanroelen, Christophe; Levecque, Katia; Louckx, Fred

    2009-02-01

    This paper presents an in-depth examination of the demand-control-support-model (DCS-model). Each hypothesis of the DCS-model is tested: the main effects of job demands, job autonomy, task variation and social support; the additive effects of job strain, active learning and iso-strain; and the interactive buffer-effects of job autonomy, task variation and support on job demands. Data from a representative cross-sectional sample of 11,099 male and female wage-earners are investigated using log linear methods. The outcome measures are self-reported persistent fatigue, musculoskeletal complaints and emotional well-being. There is some support for each of the hypotheses. Quantitative job demands and superior support have the strongest effects. The job autonomy and buffer hypotheses are only partially supported. The strong effects of job demands, support, job strain and active learning are suggesting that a policy aimed at improving psychosocial working conditions should focus on a bearable level of job demands and the quality of social relationships at work.

  10. Development and utilization of irradiational capsule - Mechanical and thermal performance analysis and development of design program on the cylindrical structures with multi-holes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Shin; Choi, M. H.; Shin, D. S. [Chungnam National University, Taejon (Korea)

    2000-04-01

    Irradiation tests in the research reactor are used with the specially designed capsules for irradiation test and loop. Accordingly, suitable instrumented capsule for HANARO must be designed and manufactured. To satisfy the requirements of users and to conduct irradiation test effectively, the accurate informations on the thermal and mechanical characteristics of capsule should be understood. The structural analysis results show that stress characteristics of the cylinder with multi-holes is not significantly effected by the sizes of specimen hole, numbers of specimen and eccentric characteristics. The thermal and structural analysis of the capsule with multi-holes under thermal loading shows that the peak temperature in the circular cylinder is occurred in the specimens inserted in the center or specimen holes and is significantly effected by gap size between the holder and the external tube. In this study, CAPSYS program is developed by interfacing finite element analysis program, ANSYS with graphic user interface program, VISUAL C++. This program will be useful on the design and safety analysis of the capsule for material irradiation test. 20 refs., 37 figs., 9 tabs. (Author)

  11. Electrotherapy modalities for adhesive capsulitis (frozen shoulder).

    Science.gov (United States)

    Page, Matthew J; Green, Sally; Kramer, Sharon; Johnston, Renea V; McBain, Brodwen; Buchbinder, Rachelle

    2014-10-01

    Adhesive capsulitis (also termed frozen shoulder) is a common condition characterised by spontaneous onset of pain, progressive restriction of movement of the shoulder and disability that restricts activities of daily living, work and leisure. Electrotherapy modalities, which aim to reduce pain and improve function via an increase in energy (electrical, sound, light, thermal) into the body, are often delivered as components of a physical therapy intervention. This review is one in a series of reviews which form an update of the Cochrane review 'Physiotherapy interventions for shoulder pain'. To synthesise the available evidence regarding the benefits and harms of electrotherapy modalities, delivered alone or in combination with other interventions, for the treatment of adhesive capsulitis. We searched CENTRAL, MEDLINE, EMBASE, CINAHL Plus and the ClinicalTrials.gov and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) clinical trials registries up to May 2014, unrestricted by language, and reviewed the reference lists of review articles and retrieved trials to identify any other potentially relevant trials. We included randomised controlled trials (RCTs) and controlled clinical trials using a quasi-randomised method of allocation that included adults with adhesive capsulitis and compared any electrotherapy modality to placebo, no treatment, a different electrotherapy modality, or any other intervention. The two main questions of the review focused on whether electrotherapy modalities are effective compared to placebo or no treatment, or if they are an effective adjunct to manual therapy or exercise (or both). The main outcomes of interest were participant-reported pain relief of 30% or greater, overall pain, function, global assessment of treatment success, active shoulder abduction, quality of life, and the number of participants experiencing any adverse event. Two review authors independently selected trials for inclusion

  12. 血滞通胶囊致肝损害%Hepatic injury induced by Xuezhitong Capsules

    Institute of Scientific and Technical Information of China (English)

    段丹丹; 祁小乐; 张雅君

    2013-01-01

    A 59-year-old women received 2 capsules of Xuezhitong capsules three times daily due to hyperlipoidemia.Before treatnent laboratory test showed the following values:total cholesterol 8.43 mmol/L,triglycerides 3.86 mmol/L,LDL cholesterol 5.28 mmol/L,alanine amino-transferase 37 U/L,aspartate aminotransferase 33 U/L,γ-glutamylacyl transferase (γ-GT) 46 U/L,and total bilirubin 10.9 μmol/L.Four weeks after receiving Xuezhitong capsules,the parameters of serum lipid were improved but γ-GT values increased to 166 U/L.Xuezhitong capsules were stopped.γ-GT values decreased to 86 U/L 2 months later and 59 U/L 3 months later.The patient self-medicated with Xuezhitong capsules again for 4 weeks and then the drug was withdrawn.Liver function test revealed γ-GT 159 U/L.Two months later γ-GT decreased to 92 U/L.%1例59岁女性患者,因高脂血症口服血滞通胶囊2粒/次,3次/d.用药前血清总胆固醇8.43 mmol/L,三酰甘油3.86 mmol/L,低密度脂蛋白胆固醇5.28 mmol/L;丙氨酸转氨酶37 U/L,天冬氨酸转氨酶33 U/L,γ-谷氨酰转移酶(γ-GT)46 U/L,总胆红素10.9 μmol/L.服用血滞通胶囊4周后血脂各项指标均有所改善,但γ-GT升高至166 U/L,遂停用血滞通胶囊.停药2个月后γ-GT下降至86 U/L,3个月后降至59 U/L.患者自行再次服用血滞通胶囊4周后停药,肝功能检测示γ-GT159 U/L,2个月后γ-GT降至92 U/L.

  13. AMMI-Biplot analysis of yield stability and test-site representativeness of proso-millet cultivars%用AMMI双标图分析糜子品种的产量稳定性及试点代表性

    Institute of Scientific and Technical Information of China (English)

    李辛村; 张恩和; 董孔军; 何继红; 杨天育

    2012-01-01

    The objective of this research was to study the stability of yield and test-site representativeness of proso-millet cultivars in China. Six cultivars were tested in nine sites in 10 m2 experimental plot under randomized completed block design and three replicates. The combination of double mark figure and special interaction [Dg(e)] of AMMI (additive main effects and multiplicative interaction) model was used to identify yield stability and test-site representativeness of the proso-millet cultivars. Analyzed data were from the national regional trials of proso-millet for 2006-2008. The results showed that the proportions of the sum of squares of genotype (G), environment (E) and G×E interactive effects on total sum of squares were 2.76%, 6.26% and 52.85%, respectively. There were significant effects in G action, E action and G×E interaction. IPCA1, IPCA2, IPCA3 accounted for up to 92.58% of the overall interaction effects. There were significant differences in stabilities of the six cultivars and representativeness of the nine test-sites. Among the six cultivars, "Yumi No.3" (CK) and "Yi8414-1-2-1" were high yield and better yield stability cultivars. "Gan9109-6-1-1-2" and "GuO1-391" exhibited less stability and high yield production. "Gan9133-l-3-4-l" showed to be a high-stability less-yield cultivar and "Gu02-25" was a low-yield unstable cultivar. For the nine test-sites, Fugu (Shaanxi Province), Tongxin (Ningxia Hui Autonomous Region), Yulin (Shaanxi Province) and Chifeng (Inner Mongolia Autonomous Region) had a better discrimination than Guyuan and Yanchi (Ningxia Hui Autonomous Region), Huining (Gansu Province), Wuzhai (Shanxi Province) and Eerduosi (Inner Mongolia Autonomous Region).%为准确评价基因型和环境互作效应对糜子品种产量稳定性及试点对品种分辨力的影响,采用AMMI模型结合双标图和稳定性参数Dg(e)对第8轮(2006-2008年)国家糜子(粳性)品种区域试验的6个品种和9个试点的试验数据进行

  14. SPARC is expressed in scars of the Tenon's capsule and mediates scarring properties of human Tenon's fibroblasts in vitro.

    Science.gov (United States)

    Fuchshofer, Rudolf; Kottler, Ulrike B; Ohlmann, Anne V; Schlötzer-Schrehardt, Ursula; Jünemann, Anselm; Kruse, Friedrich E; Ohlmann, Andreas

    2011-01-19

    To investigate the expression of the matricellular protein SPARC (secreted acidic cysteine-rich glycoprotein) in scarred human Tenon's capsule and in cultured human Tenon's fibroblasts (HTF), and to analyze the influence of SPARC on cell proliferation and collagen matrix contraction in vitro. Human Tenon's capsule scars obtained from surgical revisions after filtration surgery were analyzed for SPARC expression by immunohistochemistry. In cultured HTF cells, SPARC expression was assessed by northern and western blot analyses after incubation with transforming growth factor (TGF)-β1 and TGF-β2. Cell proliferation was determined by bromodeoxyuridine (BrdU)-labeling and HTF cells-mediated collagen matrix contraction by morphometric measurements of three-dimensional collagen lattices after treatment with SPARC and/or TGF-β1. In scarred human Tenon's capsule specimens, an increased expression of SPARC was mainly localized to the extracellular matrix and to blood vessel walls as compared to healthy control Tenon's capsule. In cultured HTF cells, treatment with TGF-β1 more than TGF-β2 induced the expression of SPARC both on the mRNA and protein level. Incubation of HTF cells with SPARC resulted in an increase in collagen matrix contraction and cell proliferation. Moreover, a combined incubation of SPARC and TGF-β1 stimulated HTF cell proliferation significantly over the levels that were observed after single treatment. Our data provide evidence that SPARC contributes to excessive wound healing and scar formation in human Tenon's capsules after filtration surgery and may thus represent a novel target for anti-fibrotic strategies.

  15. Characteristics of Standard Capsule-Type PtCo Resistance Thermometers Between 0.65 K and 25 K

    Science.gov (United States)

    Shimazaki, T.; Nakano, T.; Takasu, S.

    2017-07-01

    Standard capsule-type platinum-cobalt (PtCo) resistance thermometers represent one of the few types of resistance thermometers that have been developed for precise thermometry in the cryogenic temperature range. These thermometers remain sensitive even at 0.65 K, which is the lower limit of the ITS-90. Standard capsule-type rhodium-iron (RhFe) resistance thermometers are another type of resistance thermometer intended for use in this temperature range and have been well characterized and are the de facto standard worldwide. Existing data show RhFe resistance thermometers are more reproducible than the corresponding PtCo resistance thermometer. However, it has become difficult to obtain brand-new standard capsule-type RhFe resistance thermometers since their production was discontinued in the early 2000s. Unfortunately, information regarding the characteristics of standard capsule-type PtCo resistance thermometers is limited compared to that available for RhFe resistance thermometers. In this study, the characteristics of two standard capsule-type PtCo resistance thermometers between 0.65 K and 25 K were investigated. Because the resistance versus temperature curves for these thermometers over this temperature range exhibit two inflection points, setting break points near each of the inflection points was found to be beneficial during polynomial curve fitting to obtain mK-level precision. Special attention was paid to the reproducibility of these thermometers, and it was observed that the reproducibility of one of the thermometers within the cryogenic temperature range was ±0.5 mK over 6 years, while the second thermometer showed a larger variation. Similar trends in the resistance characteristics of the two thermometers were observed at the triple point of water.

  16. A conserved UDP-glucose dehydrogenase encoded outside the hasABC operon contributes to capsule biogenesis in group A Streptococcus.

    Science.gov (United States)

    Cole, Jason N; Aziz, Ramy K; Kuipers, Kirsten; Timmer, Anjuli M; Nizet, Victor; van Sorge, Nina M

    2012-11-01

    Group A Streptococcus (GAS) is a human-specific bacterial pathogen responsible for serious morbidity and mortality worldwide. The hyaluronic acid (HA) capsule of GAS is a major virulence factor, contributing to bloodstream survival through resistance to neutrophil and antimicrobial peptide killing and to in vivo pathogenicity. Capsule biosynthesis has been exclusively attributed to the ubiquitous hasABC hyaluronan synthase operon, which is highly conserved across GAS serotypes. Previous reports indicate that hasA, encoding hyaluronan synthase, and hasB, encoding UDP-glucose 6-dehydrogenase, are essential for capsule production in GAS. Here, we report that precise allelic exchange mutagenesis of hasB in GAS strain 5448, a representative of the globally disseminated M1T1 serotype, did not abolish HA capsule synthesis. In silico whole-genome screening identified a putative HasB paralog, designated HasB2, with 45% amino acid identity to HasB at a distant location in the GAS chromosome. In vitro enzymatic assays demonstrated that recombinant HasB2 is a functional UDP-glucose 6-dehydrogenase enzyme. Mutagenesis of hasB2 alone slightly decreased capsule abundance; however, a ΔhasB ΔhasB2 double mutant became completely acapsular. We conclude that HasB is not essential for M1T1 GAS capsule biogenesis due to the presence of a newly identified HasB paralog, HasB2, which most likely resulted from gene duplication. The identification of redundant UDP-glucose 6-dehydrogenases underscores the importance of HA capsule expression for M1T1 GAS pathogenicity and survival in the human host.

  17. Non-invasive measurement of pan-colonic pressure over a whole digestive cycle: Clinical applications of a capsule-style manometric system

    Institute of Scientific and Technical Information of China (English)

    Wen-Qiang Zhang; Guo-Zheng Yan; Lian-Zhi Yu; Xin-Qing Yang

    2006-01-01

    AIM: To study the prolonged colonic motility under normal conditions with a novel capsule-style microsystem and to assess its clinical significance.METHODS: A single use telemetry capsule (10 mm in diameter, 20 mm in length) embedded with a pressure sensor was ingested by the subjects. The sensor is capable of transmitting colonic pressure wirelessly for more than 130 h. The time of capsule entering the segmental colon was detected by ultrasound. The ultrasonic electrodes were mounted on the surface of the ileocecum and navel and at the junction of the left and rectosigmoid colon of the subjects in sequence,which were identified by abdominal X-rays with radiopaque markers. To verify the accuracy and reliability of ultrasonic detection of telemetry capsules at key points of colon, the segmental colonic transit time was simultaneously recorded by using radiopaque markers.RESULTS: The signal lamp showed that all recorders could receive the radio signal transmitted by the telemetry capsule. The X-rays showed that all telemetry capsules were detected successfully when they were passing through the key points of colon. There was a significant correlation between the transit results obtained by ultrasonic detection or by radiopaque markers. Colorectal recording was obtained from 20 healthy subjects during 613 h (411 h during waking, 202 h during sleep). Compared to waking, the number of pressure contractions and the area under pressure contractions were significantly (P < 0.05) decreased during sleep (21 ± 5 h-1 vs 15 ± 4 h-1, 463 ± 54 motility exhibited significant regional variations both in the circadian behavior and in response to waking and meal.CONCLUSION: The capsule-style micro-system is reliable and noninvasive, and may represent a useful tool for the study of physiology and pathology of colonic motor disorders.

  18. Representative mass reduction in sampling

    DEFF Research Database (Denmark)

    Petersen, Lars; Esbensen, Harry Kim; Dahl, Casper Kierulf

    2004-01-01

    We here present a comprehensive survey of current mass reduction principles and hardware available in the current market. We conduct a rigorous comparison study of the performance of 17 field and/or laboratory instruments or methods which are quantitatively characterized (and ranked) for accuracy...... always be representative in the full Theory of Sampling (TOS) sense. This survey also allows empirical verification of the merits of the famous ??Gy?s formula?? for order-of-magnitude estimation of the Fundamental Sampling Error (FSE).......We here present a comprehensive survey of current mass reduction principles and hardware available in the current market. We conduct a rigorous comparison study of the performance of 17 field and/or laboratory instruments or methods which are quantitatively characterized (and ranked) for accuracy...... dividers, the Boerner Divider, the ??spoon method??, alternate/fractional shoveling and grab sampling. Only devices based on riffle splitting principles (static or rotational) passes the ultimate representativity test (with minor, but significant relative differences). Grab sampling, the overwhelmingly...

  19. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  20. Finding the solution for incomplete small bowel capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    José; Cotter; Francisca; Dias; de; Castro; Joana; Magalhes; Maria; Joo; Moreira; Bruno; Rosa

    2013-01-01

    AIM:To evaluate whether the use of real time viewer(RTV)and administration of domperidone to patients with delayed gastric passage of the capsule could reduce the rate of incomplete examinations(IE)and improve the diagnostic yield of small bowel capsule endoscopy(SBCE).METHODS:Prospective single center interventional study,from June 2012 to February 2013.Capsule location was systematically checked one hour after ingestion using RTV.If it remained in the stomach,the patient received 10 mg domperidone per os and the location of the capsule was rechecked after 30 min.If the capsule remained in the stomach a second dose of10 mg of domperidone was administered orally.After another 30 min the position was rechecked and if the capsule remained in the stomach,it was passed into the duodenum by upper gastrointestinal(GI)endoscopy.The rate of IE and diagnostic yield of SBCE were compared with those of examinations performed before the use of RTV or domperidone in our Department(control group,January 2009-May 2012).RESULTS:Both groups were similar regarding age,sex,indication,inpatient status and surgical history.The control group included 307 patients,with 48(15.6%)IE.The RTV group included 82 patients,with3(3.7%)IE,P=0.003.In the control group,average gastric time was significantly longer in patients with IE than in patients with complete examination of the small bowel(77 min vs 26 min,P=0.003).In the RTV group,the capsule remained in the stomach one hour after ingestion in 14/82 patients(17.0%)vs 48/307(15.6%)in the control group,P=0.736.Domperidone did not significantly affect small bowel transit time(260min vs 297 min,P=0.229).The capsule detected positive findings in 39%of patients in the control group and 49%in the RTV group(P=0.081).CONCLUSION:The use of RTV and selective administration of domperidone to patients with delayed gastric passage of the capsule significantly reduces incomplete examinations,with no effect on small bowel transit time or diagnostic yield.

  1. Novel capsules for potential theranostics of obscure gastrointestinal bleedings.

    Science.gov (United States)

    Çolak, Bayram; Şakalak, Hüseyin; Çavuşoğlu, Halit; Yavuz, Mustafa Selman

    2016-09-01

    Obscure gastrointestinal (GI) bleeding is identified as persistent or repeated bleeding from the gastrointestinal tract which could not be defined by conventional gastrointestinal endoscopy and radiological examinations. These GI bleedings are assessed through invasive diagnostic and treatment methods including enteroscopy, angiography and endoscopy. In addition, video capsule endoscopy (VCE) is a non-invasive method used to determine the location of the bleeding, however, this does not provide any treatment. Despite of these successful but invasive methods, an effective non-invasive treatment is desperately needed. Herein, we prepare non-invasive theranostic capsules to cure obscure GI bleeding. An effective theranostic capsule containing endothelin as the targeting agent, thrombin-fibrinogen or fibrin as the treating agent, and fluorescein dye as the diagnostic tool is suggested. These theranostic capsules can be administered orally in a simple and non-invasive manner without a risk of complication. By using these novel capsules, one can diagnose obscure GI bleeding with having a possibility of curing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Implantable telemetry capsule for monitoring arterial oxygen saturation and heartbeat.

    Science.gov (United States)

    Kuwana, K; Dohi, T; Hashimoto, Y; Matsumoto, K; Shimoyama, I

    2008-01-01

    In this study, we have developed an implantable telemetry capsule for monitoring heartbeat. The capsule has three main functions, monitoring vital signs, transmitting the vital signs, and receiving energy for driving the capsule without wires. We used two wavelengths of LEDs and a photodiode sensitive to the two wavelengths for heartbeat sensor. The arterial oxygen saturation is calculated from the amplitude of the heartbeat signal. We fabricated an FM transmitter whose carrier frequency was 80 MHz. Though the GHz range frequency is generally used in transmission, the attenuation in the human body is large. The size of a common linear antenna is about a quarter of its operating wavelength. We employed a coil-based antenna which can reduce size below the quarter of the wavelength. We fabricated a miniaturized transmitter with the coil-based antenna at lower frequency. Our capsule was driven intermittently. We used a rechargeable battery. When the battery ran down, the battery was charged by wireless using the induced electromotive force. This means that the capsule is capable of monitoring vital signs over the long term. We measured the heartbeat from the middle finger of hand in a water tank as a model of a human body.

  3. Cuttlefish capsule: An effective shield against contaminants in the wild.

    Science.gov (United States)

    Rosa, Inês C; Raimundo, Joana; Lopes, Vanessa M; Brandão, Cláudio; Couto, Ana; Santos, Catarina; Cabecinhas, Adriana S; Cereja, Rui; Calado, Ricardo; Caetano, Miguel; Rosa, Rui

    2015-09-01

    Increasing anthropogenic pressures in estuaries are responsible for the rise of contaminants in several compartments of these ecosystems. Species that benefit from the nursery services provided by estuaries are exposed to such contaminants (e.g. metals and metalloids). It is therefore relevant to understand if marine invertebrates that use these areas as spawning grounds accumulate contaminants in their tissues throughout embryogenesis. This study aimed to quantify As, Co, Cr, Cu, Mn, Ni, Se, Pb, V and Zn concentrations in both capsule and embryos of the common cuttlefish (Sepia officinalis) in Sado Estuary (Portugal). Moreover, embryos at their initial, intermediate and final stage of development were collected in sites subjected to different anthropogenic pressures. In general, the capsule accumulated higher element concentration throughout embryogenesis which indicates that the capsule acts as an effective barrier against contaminants uptake by the embryo. Although the capsule becomes thinner throughout embryogenesis, embryo's protection does not seem to be compromised at later development stages. Additionally, the higher concentrations of As, Cu, Se and Zn in the embryo in comparison to the capsule suggests important biological roles during the embryogenesis of this cephalopod mollusc. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Pharmacokinetics of propafenone hydrochloride sustained-release capsules in male beagle dogs

    Directory of Open Access Journals (Sweden)

    Liping Pan

    2015-01-01

    Full Text Available This paper describes the development and validation of a liquid chromatography–mass spectrometric assay for propafenone and its application to a pharmacokinetic study of propafenone administered as a new propafenone hydrochloride sustained-release capsule (SR-test, as an instant-release tablet (IR-reference and as the market leader sustained-release capsule (Rythmol, SR-reference in male beagle dogs (n=8. In Study A comparing SR-test with IR-reference in a crossover design Tmax and t1/2 of propafenone for SR-test were significantly higher than those for IR-reference while Cmax and AUC were lower demonstrating the sustained release properties of the new formulation. In Study B comparing SR-test with SR-reference the observed Cmax and AUC of propafenone for SR-test (124.5±140.0 ng/mL and 612.0±699.2 ng·h/mL, respectively were higher than for SR-reference (78.52±72.92 ng/mL and 423.6±431.6 ng·h/mL, respectively although the differences were not significant. Overall, the new formulation has as good if not better sustained release characteristics to the market leader formulation.

  5. Pharmacokinetics of propafenone hydrochloride sustained-release capsules in male beagle dogs.

    Science.gov (United States)

    Pan, Liping; Qian, Yafang; Cheng, Minlu; Gu, Pan; He, Yanna; Xu, Xiaowen; Ding, Li

    2015-01-01

    This paper describes the development and validation of a liquid chromatography-mass spectrometric assay for propafenone and its application to a pharmacokinetic study of propafenone administered as a new propafenone hydrochloride sustained-release capsule (SR-test), as an instant-release tablet (IR-reference) and as the market leader sustained-release capsule (Rythmol, SR-reference) in male beagle dogs (n=8). In Study A comparing SR-test with IR-reference in a crossover design T max and t 1/2 of propafenone for SR-test were significantly higher than those for IR-reference while C max and AUC were lower demonstrating the sustained release properties of the new formulation. In Study B comparing SR-test with SR-reference the observed C max and AUC of propafenone for SR-test (124.5±140.0 ng/mL and 612.0±699.2 ng·h/mL, respectively) were higher than for SR-reference (78.52±72.92 ng/mL and 423.6±431.6 ng·h/mL, respectively) although the differences were not significant. Overall, the new formulation has as good if not better sustained release characteristics to the market leader formulation.

  6. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    Science.gov (United States)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  7. Testing Theory of Planned Behavior and Neo-Socioanalytic Theory models of trait activity, industriousness, exercise social cognitions, exercise intentions, and physical activity in a representative U.S. sample

    Science.gov (United States)

    Vo, Phuong T.; Bogg, Tim

    2015-01-01

    Prior research identified assorted relations between trait and social cognition models of personality and engagement in physical activity. Using a representative U.S. sample (N = 957), the goal of the present study was to test two alternative structural models of the relationships among the extraversion-related facet of activity, the conscientiousness-related facet of industriousness, social cognitions from the Theory of Planned Behavior (perceived behavioral control, affective attitudes, subjective norms, intentions), Social Cognitive Theory (self-efficacy, outcome expectancies), and the Transtheoretical Model (behavioral processes of change), and engagement in physical activity. Path analyses with bootstrapping procedures were used to model direct and indirect effects of trait and social cognition constructs on physical activity through two distinct frameworks – the Theory of Planned Behavior and Neo-Socioanalytic Theory. While both models showed good internal fit, comparative model information criteria showed the Theory-of-Planned-Behavior-informed model provided a better fit. In the model, social cognitions fully mediated the relationships from the activity facet and industriousness to intentions for and engagement in physical activity, such that the relationships were primarily maintained by positive affective evaluations, positive expected outcomes, and confidence in overcoming barriers related to physical activity engagement. The resultant model – termed the Disposition-Belief-Motivation model– is proposed as a useful framework for organizing and integrating personality trait facets and social cognitions from various theoretical perspectives to investigate the expression of health-related behaviors, such as physical activity. Moreover, the results are discussed in terms of extending the application of the Disposition-Belief-Motivation model to longitudinal and intervention designs for physical activity engagement. PMID:26300811

  8. Testing Theory of Planned Behavior and Neo-Socioanalytic Theory models of trait activity, industriousness, exercise social cognitions, exercise intentions, and physical activity in a representative U.S. sample.

    Science.gov (United States)

    Vo, Phuong T; Bogg, Tim

    2015-01-01

    Prior research identified assorted relations between trait and social cognition models of personality and engagement in physical activity. Using a representative U.S. sample (N = 957), the goal of the present study was to test two alternative structural models of the relationships among the extraversion-related facet of activity, the conscientiousness-related facet of industriousness, social cognitions from the Theory of Planned Behavior (perceived behavioral control, affective attitudes, subjective norms, intentions), Social Cognitive Theory (self-efficacy, outcome expectancies), and the Transtheoretical Model (behavioral processes of change), and engagement in physical activity. Path analyses with bootstrapping procedures were used to model direct and indirect effects of trait and social cognition constructs on physical activity through two distinct frameworks - the Theory of Planned Behavior and Neo-Socioanalytic Theory. While both models showed good internal fit, comparative model information criteria showed the Theory-of-Planned-Behavior-informed model provided a better fit. In the model, social cognitions fully mediated the relationships from the activity facet and industriousness to intentions for and engagement in physical activity, such that the relationships were primarily maintained by positive affective evaluations, positive expected outcomes, and confidence in overcoming barriers related to physical activity engagement. The resultant model - termed the Disposition-Belief-Motivation model- is proposed as a useful framework for organizing and integrating personality trait facets and social cognitions from various theoretical perspectives to investigate the expression of health-related behaviors, such as physical activity. Moreover, the results are discussed in terms of extending the application of the Disposition-Belief-Motivation model to longitudinal and intervention designs for physical activity engagement.

  9. Testing Theory of Planned Behavior and Neo-Socioanalytic Theory models of trait activity, industriousness, exercise social cognitions, exercise intentions, and physical activity in a representative U.S. sample

    Directory of Open Access Journals (Sweden)

    Phuong Thi Vo

    2015-08-01

    Full Text Available Prior research identified assorted relations between trait and social cognition models of personality and engagement in physical activity. Using a representative U.S. sample (N = 957, the goal of the present study was to test two alternative structural models of the relationships among the extraversion-related facet of activity, the conscientiousness-related facet of industriousness, social cognitions from the Theory of Planned Behavior (perceived behavioral control, affective attitudes, subjective norms, intentions, Social Cognitive Theory (self-efficacy, outcome expectancies, and the Transtheoretical Model (behavioral processes of change, and engagement in physical activity. Path analyses with bootstrapping procedures were used to model direct and indirect effects of trait and social cognition constructs on physical activity through two distinct frameworks – the Theory of Planned Behavior and Neo-Socioanalytic Theory. While both models showed good internal fit, comparative model information criteria showed the Theory-of-Planned-Behavior-informed model provided a better fit. In the model, social cognitions fully mediated the relationships from the activity facet and industriousness to intentions for and engagement in physical activity, such that the relationships were primarily maintained by positive affective evaluations, positive expected outcomes, and confidence in overcoming barriers related to physical activity engagement. The resultant model – termed the Disposition-Belief-Motivation model – is proposed as a useful framework for organizing and integrating personality trait facets and social cognitions from various theoretical perspectives to investigate the expression of health-related behaviors, such as physical activity. Moreover, the results are discussed in terms of extending the application of the Disposition-Belief-Motivation model to longitudinal and intervention designs for physical activity engagement.

  10. Enteric-coated capsule containing β-galactosidase-loaded polylactic acid nanocapsules: enzyme stability and milk lactose hydrolysis under simulated gastrointestinal conditions.

    Science.gov (United States)

    He, Hongjun; Zhang, Xueting; Sheng, Yan

    2014-11-01

    In order to protect peroral β-galactosidase from being degraded and hydrolyse milk lactose efficiently in the environments of gastrointestinal tract, a double-capsule delivery system composed of enteric-coated capsule and polylactic acid (PLA) nanocapsules (NCs) was developed for encapsulation of β-galactosidase. β-galactosidase-loaded PLA NCs in the size range of 100-200 nm were prepared by a modified w1/o/w2 technique. During the encapsulation process, dichloromethane/ethyl acetate (1 : 1, v/v) as the solvent composition, high-pressure homogenisation (150 bar, 3 min) as the second emulsification method and polyvinyl alcohol or Poloxamer 188 as a stabiliser in the inner phase could efficiently improve the activity retention of β-galactosidase (>90%). Subsequently, the prepared NCs were freeze-dried and filled in a hydroxypropyl methylcellulose phthalate (HP55)-coated capsule. In vitro results revealed that the HP55-coated capsule remained intact in the simulated gastric fluid and efficiently protected the nested β-galactosidase from acidic denaturation. Under the simulated intestinal condition, the enteric coating dissolved rapidly and released the β-galactosidase-loaded PLA NCs, which exhibited greater stability against enzymatic degradation and higher hydrolysis ratio (∼100%) towards milk lactose than the free β-galactosidase. These results suggest that this double-capsule delivery system represents promising candidate for efficient lactose hydrolysis in the gastrointestinal tract.

  11. Effects of trichostatin A on human Tenon capsule fibroblast

    Directory of Open Access Journals (Sweden)

    Xiao-Yan Li

    2014-11-01

    Full Text Available AIM:To investigate the effect of trichostatin A(TSAon cell proliferation and the expressions of histone deacetylase 1(HDAC1and HDAC2 in cultured human Tenon capsule fibroblast(HTF.METHODS: Human Tenon capsule fibroblasts were cultured in vitro after glaucoma filtration surgery. The third to sixth passage of cell were treated by 600nmol/L TSA or none. Cell viability measured by MTT assay after 1, 2 and 3d respectively. The expressions of HDAC1 and HDAC2 were analyzed by Western blot 2d after TSA treatment.RESULTS: Compared to the control, cell viability decreased significantly after treatment with TSA at 1d(PCONCLUSION: TSA inhibits the proliferation of Tenon capsule fibroblast by inhibiting the expression of HDAC1 and HDAC2, and reduces subconjunctival scar formation.

  12. Noncovalent encapsulation of cobaltocenium inside resorcinarene molecular capsules.

    Science.gov (United States)

    Philip, Ivy; Kaifer, Angel E

    2005-03-04

    The encapsulation of cobaltocenium (Cob+) inside hexameric molecular capsules of two different resorcinarenes was investigated in dichloromethane solution. Both 1H NMR spectroscopic and voltammetric experiments clearly reveal that Cob+ experiences encapsulation. Diffusion coefficient measurements obtained from PGSE NMR experiments indicate that the molecular capsules exist in dichloromethane solution in the absence of any cations. Bound and free Cob+ ions undergo slow exchange on the NMR time scale, but the bound Cob+ ions rotate and/or tumble freely inside the molecular capsules. Under experimental conditions suitable for voltammetry the encapsulation of Cob+ depends on the nature of the supporting electrolyte. Tetraalkylammonium hexafluorophosphate, tetrafluoroborate, and perchlorate supporting electrolytes prevent the encapsulation of Cob+, while tetraalkylammonium chloride and bromide salts allow it. The nature of the tetraalkylammonium cation plays a smaller role in the encapsulation. Finally, the structure of the resorcinarene also factors into the overall stability of the molecular assembly.

  13. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  14. Wzy-dependent bacterial capsules as potential drug targets.

    Science.gov (United States)

    Ericsson, Daniel J; Standish, Alistair; Kobe, Bostjan; Morona, Renato

    2012-10-01

    The bacterial capsule is a recognized virulence factor in pathogenic bacteria. It likely works as an antiphagocytic barrier by minimizing complement deposition on the bacterial surface. With the continual rise of bacterial pathogens resistant to multiple antibiotics, there is an increasing need for novel drugs. In the Wzy-dependent pathway, the biosynthesis of capsular polysaccharide (CPS) is regulated by a phosphoregulatory system, whose main components consist of bacterial-tyrosine kinases (BY-kinases) and their cognate phosphatases. The ability to regulate capsule biosynthesis has been shown to be vital for pathogenicity, because different stages of infection require a shift in capsule thickness, making the phosphoregulatory proteins suitable as drug targets. Here, we review the role of regulatory proteins focusing on Streptococcus pneumoniae, Staphylococcus aureus, and Escherichia coli and discuss their suitability as targets in structure-based drug design.

  15. Demonstration of bacteroides capsules by light microscopy and ultrastructural cytochemistry.

    Science.gov (United States)

    Strohm, H; Payne, C M; Ryan, K J

    1983-05-01

    Forty-six anaerobic gram-negative bacilli, including 26 members of the Bacteroides fragilis group (BFG), were examined for capsules by the India ink technic. Thirty-five were encapsulated, including all the BFG strains. As a follow-up, seven of these isolates and two previously studied reference strains (B. fragilis ATCC 23745 and Bacteroides vulgatus ATCC 8482) were examined for capsules by ultrastructural cytochemistry. Using the periodic acid thiocarbohydrazide silver proteinate (PATCSP) method of Thiéry, all the BFG examined were encapsulated. In addition to the reference strains, this included one strain of B. fragilis and four of Bacteroides thetaiotaomicron. One non-BFG strain showed no capsular material. Differences between these results and those reported previously with the ruthenium red technic may reflect species differences in the chemical composition of Bacteroides capsules.

  16. Controllable light capsules employing modified Bessel-Gauss beams

    CERN Document Server

    Gong, Lei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new rou...

  17. Inhibitive Effects of Quercetin on Rabbit Tenon Capsule Fibroblasts Proliferation

    Institute of Scientific and Technical Information of China (English)

    Su Liu; Lin Chen

    2005-01-01

    Purpose:To study the inhibitive effects of quercetin (QU) on the fibroblasts proliferation of rabbit Tenon's capsule and its mechanism.Methods: Cultured fibroblasts were exposed to different concentrations of QU solution and investigated by microculture tetrazolium (MTT) assay. The effect of QU was obser ved on cells cycle using the flow cytometer. Besults: QU can suppress the proliferation of rabbit Tenon's capsule fibroblasts in vitro and show a dose-time dependent tendency.Flow cytometer results showed 26.92% cell increase in G1 phase, 23.50% decrease in S phase and 3.42% decrease in G2 phase.Conclusions: QU can suppress the proliferation of rabbit Tenon's capsule fibroblasts in vitro and show a dose-time dependent tendency. QU may effect all phase of cell cycle and inhibit cell proliferation by inhibiting G1 phase transitting to S phase and G2 phase.

  18. Rayleigh Taylor Instability Growth in NIC Capsules with Engineered Defects

    Science.gov (United States)

    Peterson, K. J.; Hammel, B. A.; Suter, L. J.; Clark, D. S.; Farley, D. R.; Landen, O. L.; Scott, H.; Moreno, K.; Vesey, R. A.; Herrmann, M. C.; Nakhleh, C. W.; Golovkin, I.; Regan, S. P.; Epstein, R.

    2011-10-01

    In order to achieve thermonuclear burn and energy gain in ICF capsules, the growth of hydrodynamic instabilities must be understood and controlled. Experiments are planned to measure time dependent hydrodynamic instability growth of engineered defects on the surface of NIC capsules using x-ray radiography. We will present an analysis of synthetic radiography from 2D and 3D HYDRA simulations with various x-ray drive fluxes and show how these results will be used to assess code predictions of instability growth and mix. We will also discuss how these results correlate with capsule performance and observables from hot spot self emission imaging and Ge spectroscopy. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  19. Development of Beryllium-Copper Alloy Ignition Capsules

    Science.gov (United States)

    Cooley, Jason; Alexander, David; Thoma, Daniel; Field, Robert; Day, Robert; Cameron, Bernard; Nobile, Arthur; Rivera, Gerald; Kelly, Ann; Papin, Pallas; Schulze, Roland; Dauelsberg, Lawrence; Alexander, Neil; Galix, Remy

    2004-11-01

    Cu-doped Be capsules are being developed for ignition on the National Ignition Facility (NIF). Our fabrication approach is based on bonding of cylindrical parts containing precision machined hemispherical cavities, followed by machining an external spherical contour to produce a spherical shell. While we have demonstrated this approach, there are several key issues that need to be resolved before a shell meeting NIF specifications can be produced. These issues are synthesis of high purity small grain size Be0.9at%Cu alloy, formation of a strong hemishell bond that will allow the capsule to contain its 400 atm fill gas at room temperature, precision machining and polishing of the capsule to meet stringent specifications for surface finish and spherical quality, and filling with DT. In this paper we report on the progress that has been made in resolving these key issues.

  20. Trade study for the disposition of cesium and strontium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Claghorn, R.D.

    1996-03-01

    This trade study analyzes alternatives for the eventual disposal of cesium and strontium capsules currently stored at the Waste Encapsulation and Storage Facility as by-product. However, for purposes of this study, it is assumed that at some time in the future, the capsules will be declared high-level waste and therefore will require disposal at an offsite geologic repository. The study considered numerous alternatives and selected three for detailed analysis: (1) overpack and storage at high-level waste canister storage building, (2) overpack at the high-level waste vitrification facility followed by storage at a high-level waste canister storage building, and (3) blend capsule contents with other high-level waste feed streams and vitrify at the high-level waste vitrification facility.

  1. Characterization of the Kingella kingae polysaccharide capsule and exopolysaccharide.

    Directory of Open Access Journals (Sweden)

    Kimberly F Starr

    Full Text Available Recent evidence indicates that Kingella kingae produces a polysaccharide capsule. In an effort to determine the composition and structure of this polysaccharide capsule, in the current study we purified capsular material from the surface of K. kingae strain 269-492 variant KK01 using acidic conditions to release the capsule and a series of steps to remove DNA, RNA, and protein. Analysis of the resulting material by gas chromatography and mass spectrometry revealed N-acetyl galactosamine (GalNAc, 3-deoxy-D-manno-oct-2-ulosonic acid (Kdo, and galactose (Gal. Further analysis by NMR demonstrated two distinct polysaccharides, one consisting of GalNAc and Kdo with the structure →3-β-GalpNAc-(1→5-β-Kdop-(2→ and the other containing galactose alone with the structure →5-β-Galf-(1→. Disruption of the ctrA gene required for surface localization of the K. kingae polysaccharide capsule resulted in elimination of GalNAc and Kdo but had no effect on the presence of Gal in bacterial surface extracts. In contrast, deletion of the pamABCDE locus involved in production of a reported galactan exopolysaccharide eliminated Gal but had no effect on the presence of GalNAc and Kdo in surface extracts. Disruption of ctrA and deletion of pamABCDE resulted in a loss of all carbohydrates in surface extracts. These results establish that K. kingae strain KK01 produces a polysaccharide capsule with the structure →3-β-GalpNAc-(1→5-β-Kdop-(2→ and a separate exopolysaccharide with the structure →5-β-Galf-(1→. The polysaccharide capsule and the exopolysaccharide require distinct genetic loci for surface localization.

  2. Effect of small bowel preparation with simethicone on capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    You-hong FANG; Chun-xiao CHEN; Bing-ling ZHANG

    2009-01-01

    Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition ofsimethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and sime-thicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intes-tines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.

  3. First beryllium capsule implosions on the National Ignition Facility

    Science.gov (United States)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B.; Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F.; Haan, S. W.; Celliers, P. M.; Clark, D. S.; Hammel, B. A.; Kozioziemski, B.; Schneider, M. B.; Marinak, M. M.; Rinderknecht, H. G.; Robey, H. F.; Salmonson, J. D.; Patel, P. K.; Ma, T.; Edwards, M. J.; Stadermann, M.; Baxamusa, S.; Alford, C.; Wang, M.; Nikroo, A.; Rice, N.; Hoover, D.; Youngblood, K. P.; Xu, H.; Huang, H.; Sio, H.

    2016-05-01

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  4. Silicone Oil Tamponade Combined with Lensectomy Preserving Anterior Lens Capsule

    Institute of Scientific and Technical Information of China (English)

    LuL; YangJ

    1999-01-01

    Purpose:To investigate the therapeutic effect and indicatio n of silicone oil tamponade combined with lensectomy preserving anterior lens capsule.Methods:Silicone oil tamponade combined with lensectomy preserving anterior lens capsule was performed in 33 cases (33 eyes)of high myopia ,proliferative vitroretinopathy(PVR)D grade and giant retinal tear(GRT).10 cases were onlyeye and 11 cases had harder nucleus of lens.The surgical methods included:1.smashing lens nucleus and lensectomy preserving complete anterior capsule;2,vitrectomy and membrane peeling;3,usage of liquid perfluorocarbin or retinotomy or drainage;4.silicone oil tamponade;5.postoperative Nd;YAG laser for anterior capsulectomy. Results:Follow-up time was 6 months or more in 29 cases.Total retinal reattachment was achieved in 22 cases,macular retinal reattachment in 5 cases.The visual acuity was 20/800 to 20/200 in 13 cases,20/100 to 20/50 in 12 cases.Visual acuity was significantly improved in GRT group(P<0.05).Complications included unexpected anterior capsule break intraoperatively,anterior capsule opacity,silicone oil emulsification and liquid perfluorocarbin remainig postoperatively.Conclusions:Silicone oil tamponade combined with lensectomy preserving anterior capsule was safe and can reduce the operative complications.The indications included:1.GRT complicated with high myopia;2,advanced PVR cases complicated with high myopia in which silicone oil must be used;3.severe lens opacity cases in which silicone oil must be used;4.complex retinal detachment of only ye.

  5. First beryllium capsule implosions on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B.; Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F.; Haan, S. W.; Celliers, P. M.; Clark, D. S.; Hammel, B. A.; Kozioziemski, B.; Schneider, M. B.; Marinak, M. M.; Rinderknecht, H. G.; Robey, H. F.; Salmonson, J. D.; Patel, P. K.; Ma, T.; Edwards, M. J.; Stadermann, M.; Baxamusa, S.; Alford, C.; Wang, M.; Nikroo, A.; Rice, N.; Hoover, D.; Youngblood, K. P.; Xu, H.; Huang, H.; Sio, H.

    2016-05-01

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  6. Socioeconomic and familial characteristics influence caretakers' adherence to the periodic vitamin A capsule supplementation program in Central Java, Indonesia.

    Science.gov (United States)

    Pangaribuan, Rosnani; Scherbaum, Veronika; Erhardt, Jürgen G; Sastroamidjojo, Soemilah; Biesalski, Hans K

    2004-06-01

    The adherence of program participants to periodic vitamin A capsule (VAC) supplementation among children aged 1-5 years (n = 677) in Central Java, Indonesia was assessed. Fourteen villages from five sub-districts and one ward from one sub-district in Central Java were included in the study to represent rural and suburban areas. All questions about demographic factors, socioeconomic conditions, current dietary practice and healthcare-seeking attitudes for common childhood illnesses, previous breastfeeding experience, their knowledge about vitamin A and adherence to the VAC program after capsule distribution (two periods in 2000) were asked. Caretakers with limited knowledge about the health benefits of vitamin A, households with more than one preschool child, and households with older children (> 36 months) were associated with a decreased likelihood of regular participation in the program with odds ratios of 0.38, 0.55, and 0.26, respectively (p program regularly with an odds ratio of 2.02 (p program.

  7. 用GGE双标图分析甘蔗品种性状稳定性及试点代表性%Trait stability and test site representativeness of sugarcane varieties based on GGE-biplot analysis

    Institute of Scientific and Technical Information of China (English)

    罗俊; 张华; 邓祖湖; 阙友雄

    2012-01-01

    算术平均法经常被用于评估甘蔗品种产量的稳定性和适应性,并用方差分析来估计区域试验的试验误差.然而,地点和年份的差异使品种的差异难以得到准确评估.为客观评价甘蔗品种的稳定性和适应性,本研究采用GGE双标图对2008-2009年我国甘蔗区域试验5个试点中的7个甘蔗品种试验数据进行分析.结果表明:福农30号为蔗茎产量高且稳产性高的品种,粤甘18号为含糖量高且性状稳定的品种,福农28号和云蔗99-91为高蔗糖分且性状稳定的品种,粤甘16号的蔗茎产量和含糖量最高,但稳定性一般;在各试点中,福建漳州和广东遂溪的代表性和鉴别力较强.GGE双标图分析为客观评价甘蔗参试品种的丰产性和稳定性提供了直观、有效的手段,为甘蔗新品种的鉴定与推广提供了科学依据.%Arithmetic mean method is commonly used to evaluate the yield stability and adaptability of sugarcane varieties, and variance analysis is applied to estimate the errors in regional trials. However, it is difficult to accurately evaluate the differences of the varieties due to the discrepancies across test sites and years. In this paper, GGE-biplot method was adopted to analyze the data from the regional trials with seven sugarcane varieties at five sites from 2008 to 2009, aimed to objectively evaluate the yield stability and adaptability of sugarcane varieties in China. Among the test sugarcane varieties, Funong No. 30 had higher cane yield and better yield stability, Yuegan No. 18 had higher sugar content and better trait stability, Funong No. 28 and Yunzhe 99-91 had high sucrose content and trait stability, while Yuegan No. 16 had the highest cane yield and sugar content but ordinary stability. In the test sites, Zhangzhou City in Fujian Province and Suixi City in Guangdong Province had the best representativeness and discrimination. This study showed that GGE-biplot analysis provided a simple and

  8. Feasibility of Dynamic Stability Measurements of Planetary Entry Capsules Using MSBS

    Science.gov (United States)

    Britcher, Colin; Schoenenberger, Mark

    2015-01-01

    The feasibility of conducting dynamic stability testing of planetary entry capsules at low supersonic Mach numbers using a Magnetic Suspension and Balance System (MSBS) is reviewed. The proposed approach would employ a spherical magnetic core, exert control in three degrees-of-freedom (i.e. x, y, z translations) and allow the model to freely rotate in pitch, yaw, and roll. A proof-of-concept system using an existing MSBS electromagnet array in a subsonic wind tunnel is described, with future potential for development of a new system for a supersonic wind tunnel.

  9. Small-bowel neoplasms in patients undergoing video capsule endoscopy

    DEFF Research Database (Denmark)

    Rondonotti, E; Pennazio, M; Toth, E

    2008-01-01

    BACKGROUND AND STUDY AIM: Small-bowel tumors account for 1% - 3% of all gastrointestinal neoplasms. Recent studies with video capsule endoscopy (VCE) suggest that the frequency of these tumors may be substantially higher than previously reported. The aim of the study was to evaluate the frequency...... findings. 55 patients underwent VCE as the third procedure after negative bidirectional endoscopy. The lesions were single in 89.5% of cases, and multiple in 10.5%. Retention of the capsule occurred in 9.8% of patients with small-bowel tumors. After VCE, 54/124 patients underwent 57 other examinations...

  10. Steady state heat transfer in ORR irradiation capsules. Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Michel, R.C.; Michaels, S.L.; Wilkes, G.R.

    1976-04-26

    The mathematical model developed by Stiros for prediction of temperature profiles in ORR irradiation capsules was modified and a numerical solution obtained. A Fortran computer program was written to solve the generalized finite difference equations applied to a fixed lattice system superimposed on the capsule cross section. The Liebmann iterative method was employed. The solution accounts for changes in internal heat generation, thermal expansion, and thermal conductivity induced by both temperature and fluence. The computed temperatures deviated from actual experimental measurements in the fuel rods by less than 2.0 percent.

  11. Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    Science.gov (United States)

    Spada, C; Hassan, C; Galmiche, J P; Neuhaus, H; Dumonceau, J M; Adler, S; Epstein, O; Gay, G; Pennazio, M; Rex, D K; Benamouzig, R; de Franchis, R; Delvaux, M; Devière, J; Eliakim, R; Fraser, C; Hagenmuller, F; Herrerias, J M; Keuchel, M; Macrae, F; Munoz-Navas, M; Ponchon, T; Quintero, E; Riccioni, M E; Rondonotti, E; Marmo, R; Sung, J J; Tajiri, H; Toth, E; Triantafyllou, K; Van Gossum, A; Costamagna, G

    2012-05-01

    PillCam colon capsule endoscopy (CCE) is an innovative noninvasive, and painless ingestible capsule technique that allows exploration of the colon without the need for sedation and gas insufflation. Although it is already available in European and other countries, the clinical indications for CCE as well as the reporting and work-up of detected findings have not yet been standardized. The aim of this evidence-based and consensus-based guideline, commissioned by the European Society of Gastrointestinal Endoscopy (ESGE) is to furnish healthcare providers with a comprehensive framework for potential implementation of this technique in a clinical setting.

  12. A parametric study on ice formation inside a spherical capsule

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, K.A.R.; Silva, T.M. da [Depto. de Engenharia Termica e de Fluidos - FEM-UNICAMP CP: 6122, CEP 13083-970, SP, Campinas (Brazil); Henriquez, J.R. [Depto. de Engenharia Mecanica - DEMEC, UFPE, CEP 50740-530, PE, Recife (Brazil)

    2003-09-01

    This paper reports the results of a numerical study on the heat transfer during the process of solidification of water inside a spherical capsule. The governing equations of the problem and associated boundary conditions were formulated and solved using a finite difference approach and a moving grid scheme. The model was optimized and the numerical predictions were validated by comparison with experimental results realized by the authors. The model was also used to investigate the effects of the size and material of the shell, initial temperature of the phase change material and the external temperature of the spherical capsule on the solidified mass fraction and the time for the complete solidification. (authors)

  13. Mechanism of Erhuang capsule for treatment of multiple sclerosis.

    Science.gov (United States)

    Li, Kangning; Fan, Yongping; Yang, Tao; Wang, Lei

    2013-02-25

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation.

  14. Mechanism of Erhuang capsule for treatment of multiple sclerosis☆

    Science.gov (United States)

    Li, Kangning; Fan, Yongping; Yang, Tao; Wang, Lei

    2013-01-01

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation. PMID:25206695

  15. DC polarographic and spectrophotometric determination of ampicillin capsules.

    Science.gov (United States)

    Squella, J A; Nunez-Vergara, L J; Aros, M

    1980-09-01

    Polarographic and spectrophotometric methods are proposed for the determination of ampicillin in capsules. Acidic hydrolysis of ampicillin with 1% HCHO in 0.3N HCl yields a degradation product identified as 2-hydroxy-3-phenyl-6-methylpyrazine. This compound has a well defined UV absorption band at 380 nm and a polarographic wave at -0.55 V vs SCE, which can be used for analytical purposes. Individual capsule assays, composite assays, and recovery studies are described. The average recovery values and standard deviations (SD) for UV and polarographic determinations were 99.20% (SD 0.95) and 100.85% (SD 1.09), respectively.

  16. Preshot Predictions for Defect Induced Mix (DIME) Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, Paul A. [Los Alamos National Laboratory; Krasheninnikova, Natalia S. [Los Alamos National Laboratory; Tregillis, Ian L. [Los Alamos National Laboratory; Schmitt, Mark J. [Los Alamos National Laboratory

    2012-07-31

    In this memo, we evaluate the most probable yield and other results for the Defect Induced Mix (DIME-12A) Polar Direct Drive (PDD) capsule-only shots. We evaluate the expected yield, bang time, burn averaged ion temperature, and the average electron temperature of the Ge line-emitting region. We also include synthetic images of the capsule backlit by Cu K-{alpha} emission (8.39 keV) and core self-emission synthetic images. This memo is a companion to the maximum credible yield memo (LA-UR-12-00287) published earlier.

  17. A novel localization method for noninvasive monitoring capsule

    Institute of Scientific and Technical Information of China (English)

    He Wenhui; Yan Guozheng; Jiang Pingping; Guo Xudong

    2006-01-01

    Noninvasive monitoring capsule for gastrointestinal tract can be swallowed by patient. It is of great importance for the physician to monitor the precise position of capsule in gastrointestinal tract. The authors investigated a novel method for it. Using three coils with DC current to excite magnetic field and one triaxial magnetoresistive sensor to measure the excited magnetic vectors, they tried to solve the problem.The authors provided the localization principle of the method and analyzed it by an experiment, too. The method may be applied in practice in the future though it is still immature now.

  18. Mechanism of Erhuang capsule for treatment of multiple sclerosis

    Institute of Scientific and Technical Information of China (English)

    Kangning Li; Yongping Fan; Tao Yang; Lei Wang

    2013-01-01

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation.

  19. Multicenter clinical study on Fuzhenghuayu capsule against liver fibrosis due to chronic hepatitis B

    Institute of Scientific and Technical Information of China (English)

    Ping Liu; Mo-Bin Wan; Xiong Cai; Zhi-Qing Zhang; Jun Ye; Ren-Xing Zhou; Jia He; Bao-Zhang Tang; Yi-Yang Hu; Cheng Liu; Lie-Ming Xu; Cheng-Hai Liu; Ke-Wei Sun; De-Chang Hu; You-Kuan Yin; Xia-Qiu Zhou

    2005-01-01

    AIM: To study the efficacy and safety of Fuzhenghuayu capsule (FZHY capsule, a capsule for strengthening body resistance to remove blood stasis) against liver fibrosis due to chronic hepatitis B. METHODS: Multicenter, randomized, double blinded and parallel control experiment was conducted in patients (aged from 18 to 65 years) with liver fibrosis due to chronic hepatitis B. Hepatic histologic changes and HBV markers were examined at wk 0 and 24 during treatment. Serologic parameters (HA, LM, P-Ⅲ-P, Ⅳ-C) were determined and B ultrasound examination of the spleen and liver was performed at wk 0, 12 and 24. Liver function (liver function and serologic parameters for liver fibrosis) was observedat wk 0, 6, 12, 18 and 24. Blood and urine routine test, renal function and ECG were examined before and after treatment. RESULTS: There was no significant difference between experimental group (110 cases) and control group (106 cases) in demographic features, vital signs, course of illness, history for drug anaphylaxis and previous therapy, liver function, serologic parameters for liver fibrosis, liver histologic examination (99 cases in experimental group, 96 cases in control group), HBV markers, and renal function. According to the criteria for liver fibrosis staging, meanscore of fibrotic stage(s) in experimental group after treatment (1.80) decreased significantly compared to the previous treatment (2.33, P<0.05), but there was no significant difference in mean score of fibrotic stage(s) (2.11 and 2.14 respectively). There was a significant difference in reverse rate between experimental group (52%) and control group (23.3%) in liver biopsy. With marked effect on decreasing the mean value of inflammatory activity and score of inflammation (P<0.05), Fuzhenghuayu capsule had rather good effects on inhibiting inflammatory activity and was superior to that of Heluoshugan capsule. Compared to that of pretreatment, there was a significant decrease in HA, LM, P-Ⅲ-P and

  20. 77 FR 35985 - Determination That PARAPLATIN (Carboplatin) Injection and SUSTIVA (Efavirenz) Capsules Were Not...

    Science.gov (United States)

    2012-06-15

    ... SUSTIVA (Efavirenz) Capsules Were Not Withdrawn From Sale for Reasons of Safety or Effectiveness AGENCY... (efavirenz) Capsule, 100 Bristol Myers Squibb. milligrams (mg). NDA 20-452 PARAPLATIN (carboplatin) Do...

  1. Pilot study trialling a new ambulatory method for the clinical assessment of regional gastrointestinal transit using multiple electromagnetic capsules.

    Science.gov (United States)

    Haase, A M; Gregersen, T; Schlageter, V; Scott, M S; Demierre, M; Kucera, P; Dahlerup, J F; Krogh, K

    2014-12-01

    Gastrointestinal (GI) motor disorders often involve several regions of the GI tract. Therefore, easy and safe assessment of whole gut and regional motility is valuable for more precise diagnosis. 3D-Transit is a novel method for ambulatory evaluation of total and regional gastrointestinal transit times (GITT) based on the anatomical localization of ingestible electromagnetic capsules. The main purpose of this study was to test the performance of the 3D-Transit system. Twenty healthy volunteers each ingested three electromagnetic capsules over a period of two consecutive days. Standard radio-opaque markers (ROM) were also ingested to assess the agreement between total GITT obtained with both methods. Investigations were well-tolerated and three capsules could be tracked simultaneously with minimal data loss (Capsule 1: median: 0.2% of time (range 0-25.3%). Region specific contraction patterns were identified and used for computation of total and regional GITT in all subjects. Inter-observer agreement was 100% for total GITT (median variation 0%) but less for regional GITT. Day-to-day and diurnal variations were significant for total and regional GITT. Total GITT assessed by 3D-Transit capsules were moderately well-correlated to those assessed with standard ROM (Spearman's rho = 0.7). 3D-transit is a well-tolerated and minimal invasive ambulatory method for assessment of GI motility. By providing both total and regional transit times, the 3D-Transit system holds great promise for future clinical studies of GI function in health and disease. © 2014 John Wiley & Sons Ltd.

  2. Cellulose nanofiber/nanocrystal reinforced capsules: a fast and facile approach toward assembly of liquid-core capsules with high mechanical stability.

    Science.gov (United States)

    Svagan, Anna J; Musyanovych, Anna; Kappl, Michael; Bernhardt, Max; Glasser, Gunnar; Wohnhaas, Christian; Berglund, Lars A; Risbo, Jens; Landfester, Katharina

    2014-05-12

    Liquid-core capsules of high mechanical stability open up for many solid state-like applications where functionality depending on liquid mobility is vital. Herein, a novel concept for fast and facile improvement of the mechanical properties of walls of liquid-core capsules is reported. By imitating nature's own way of enhancing the mechanical properties in liquid-core capsules, the parenchyma plant cells found in fruits and vegetables, a blend of short cellulose nanofibers (capsule walls. The NFC/CNC blend was prepared from a new version of the classical wood pulp hydrolysis. The capsule shell consisted of a covalently (by aromatic diisocyanate) cross-linked NFC/CNC structure at the outer capsule wall and an inner layer dominated by aromatic polyurea. The mechanical properties revealed an effective capsule elastic modulus of 4.8 GPa at 17 wt % NFC/CNC loading, about six times higher compared to a neat aromatic polyurea capsule (0.79 GPa) and 3 orders of magnitude higher than previously reported capsules from regenerated cellulose (0.0074 GPa). The outstanding mechanical properties are ascribed to the dense nanofiber structure, present in the outer part of the capsule wall, that is formed by oriented NFC/CNC of high average aspect ratio (L/d ∼ 70) and held together by both covalent (urethane bonds) and physical bonds (hydrogen bonds).

  3. Swallowable capsule with air channel for improved image-guided cancer detection in the esophagus

    Science.gov (United States)

    Seibel, Eric J.; Melville, C. David; Lung, Jonathan K. C.; Babchanik, Alexander P.; Lee, Cameron M.; Johnston, Richard S.; Dominitz, Jason A.

    2009-02-01

    A new type of endoscope has been developed and tested in the human esophagus, a tethered-capsule endoscope (TCE) that requires no sedation for oral ingestion and esophageal inspection. The TCE uses scanned red, green, and blue laser light to image the upper digestive tract using a swallowable capsule of 6.4mm in diameter and 18mm in length on a 1.4mm diameter tether. The TCE has been modified for image-guided interventions in the lower esophagus, specifically for more effective detection and measurement of the extent of Barrett's esophagus, a precursor to esophageal cancer. Three modifications have been tested in vivo: (1) weighting the capsule so it is negatively buoyant in water, (2) increasing the frame rate of 500-line images to 30 Hz (video rate), and (3) adding a 1.0mm inner diameter working channel alongside the tether for distending the lower esophagus with air pressure during endoscopy. All three modifications proved effective for more clearly visualizing the lower esophagus in the first few human subjects. The air channel was especially useful because it did not change tolerability in the first subject for unsedated endoscopy and the air easily removed bubbles obscuring tissue from the field of view. The air provided a non-invasive intervention by stimulating the mechanosensor of the lower esophageal sphincter at the precise time that the TCE was positioned for most informative imaging. All three TCE modifications proved successful for improved visualization of esophageal pathology, such as suspected Barrett's esophagus, without the use of sedation.

  4. What is the impact of capsule endoscopy in the long term period?

    Institute of Scientific and Technical Information of China (English)

    Asli Ormeci; Filiz Akyuz; Bulent Baran; Suut Gokturk; Tugrul Ormeci; Binnur Pinarbasi; Ozlem Mutluay Soyer; Sami Evirgen; Umit Akyuz; Cetin Karaca; Kadir Demir; Sabahattin Kaymakoglu; Fatih Besisik

    2016-01-01

    AIM: To assess the clinical impact of capsule endoscopy(CE) in the long-term follow-up period in patients with obscure gastrointestinal bleeding(OGIB). METHODS: One hundred and forty-one patients who applied CE for OGIB between 2009 and 2012 were retrospectively analyzed, and this cohort was then questioned prospectively. Demographic data of the patients were determined via the presence of comorbid diseases, use of non-steroidal anti-inflammatory drugs anticoagulant-antiaggregant agents, previous diagnostic tests for bleeding episodes, CE findings, laboratory tests and outcomes.RESULTS: CE was performed on 141 patients becauseof OGIB. The capsule was retained in the upper gastrointestinal(GI) system in two of the patients, thus video monitoring was not achieved. There were 139 patients [62% male, median age: 72 years(range: 13-93 years) and a median follow-up duration: 32 mo(range: 6-82 mo)]. The overall diagnostic yield of CE was 84.9%. Rebleeding was determined in 40.3%(56/139) of the patients. The rebleeding rates of patients with positive and negative capsule results at the end of the follow-up were 46.6%(55/118) and 4.8%(1/21), respectively. In the multivariate analysis, usage of NSAIDs, anticoagulant-antiaggregant therapies(OR = 5.8; 95%CI: 1.86-18.27) and vascular ectasia(OR = 6.02; 95%CI: 2.568-14.146) in CE were detected as independent predictors of rebleeding. In the univariate analysis, advanced age, comorbidity, and overt bleeding were detected as predictors of rebleeding.CONCLUSION: CE is a reliable method in the diagnosis of obscure GI bleeding. Negative CE correlated with a significantly lower rebleeding risk in the long-term follow-up period.

  5. Acute effect of scapular proprioceptive neuromuscular facilitation (PNF) techniques and classic exercises in adhesive capsulitis: a randomized controlled trial.

    Science.gov (United States)

    Balcı, Nilay Comuk; Yuruk, Zeliha Ozlem; Zeybek, Aslican; Gulsen, Mustafa; Tekindal, Mustafa Agah

    2016-04-01

    [Purpose] The aim of our study was to compare the initial effects of scapular proprioceptive neuromuscular facilitation techniques and classic exercise interventions with physiotherapy modalities on pain, scapular dyskinesis, range of motion, and function in adhesive capsulitis. [Subjects and Methods] Fifty-three subjects were allocated to 3 groups: scapular proprioceptive neuromuscular facilitation exercies and physiotherapy modalities, classic exercise and physiotherapy modalities, and only physiotherapy modalities. The intervention was applied in a single session. The Visual Analog Scale, Lateral Scapular Slide Test, range of motion and Simple Shoulder Test were evaluated before and just after the one-hour intervention in the same session (all in one session). [Results] All of the groups showed significant differences in shoulder flexion and abduction range of motion and Simple Shoulder Test scores. There were statistically significant differences in Visual Analog Scale scores in the proprioceptive neuromuscular facilitation and control groups, and no treatment method had significant effect on the Lateral Scapular Slide Test results. There were no statistically significant differences between the groups before and after the intervention. [Conclusion] Proprioceptive neuromuscular facilitation, classic exercise, and physiotherapy modalities had immediate effects on adhesive capsulitis in our study. However, there was no additional benefit of exercises in one session over physiotherapy modalities. Also, an effective treatment regimen for shoulder rehabilitation of adhesive capsulitis patients should include scapular exercises.

  6. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  7. 75 FR 39024 - Determination That ACCUTANE (Isotretinoin) Capsules, 10 Milligrams, 20 Milligrams, and 40...

    Science.gov (United States)

    2010-07-07

    ... HUMAN SERVICES> Food and Drug Administration Determination That ACCUTANE (Isotretinoin) Capsules, 10... Administration (FDA) is announcing its determination that ACCUTANE (isotretinoin) Capsules, 10 milligrams (mg...) Capsules, 10 mg, 20 mg, and 40 mg, are the subject of NDA 18-662, held by Hoffman-La Roche, Inc. (Roche...

  8. 10 CFR 32.21 - Radioactive drug: Manufacture, preparation, or transfer for commercial distribution of capsules...

    Science.gov (United States)

    2010-01-01

    ... for commercial distribution of capsules containing carbon-14 urea each for âin vivoâ diagnostic use..., preparation, or transfer for commercial distribution of capsules containing carbon-14 urea each for “in vivo... commercial distribution capsules containing 37 kBq (1 µCi) carbon-14 urea (allowing for nominal variation...

  9. 75 FR 76017 - Determination That GLEEVEC (Imatinib Mesylate) Capsules, 50 Milligrams and 100 Milligrams, Were...

    Science.gov (United States)

    2010-12-07

    ... HUMAN SERVICES Food and Drug Administration Determination That GLEEVEC (Imatinib Mesylate) Capsules, 50... determined that GLEEVEC (imatinib mesylate) Capsules, 50 milligrams (mg) and 100 mg, were not withdrawn from... new drug applications (ANDAs) for imatinib mesylate capsules, 50 mg and 100 mg, if all other legal and...

  10. 75 FR 52768 - Withdrawal of Approval of New Animal Drug Applications; Dichlorophene and Toluene Capsules

    Science.gov (United States)

    2010-08-27

    ...; Dichlorophene and Toluene Capsules AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food... use of dichlorophene and toluene deworming capsules for cats and dogs. In a final rule published... withdraw approval of NADA 101-497 for TINY TIGER (dichlorophene/toluene) Worming Capsules, NADA 101-498 for...

  11. Investigation on the aerosol performance of dry powder inhalation hypromellose capsules with different lubricant levels.

    Science.gov (United States)

    Saleem, I Y; Diez, F; Jones, B E; Kayali, N; Polo, L

    2015-08-15

    HPMC capsules are made by a dipping process and a surface lubricant for the mould pins is an essential processing aid for removing dried capsules shells. For the purpose of this study, the level was determined by quantifying methyloleate (MO) a component found in the lubricant but not in the hypromellose capsules. Here we investigated the influence of the lubricant, low (10.81 μg/capsule=60 mg/kg MO), medium (15.97 μg/capsule=90 mg/kg MO) and high (23.23 μg/capsule=127 mg/kg MO) content on powder (binary mixture of salbutamol: lactose, 1:50 w/w) aerosolization properties was investigated. Results indicated significantly lower emitted dose from capsules with 60 mg/kg MO. Furthermore, the 90 and 127 mg/kg MO level of lubricant capsules produced almost double the Fine Particle Dose & Fine Particle Fraction compared with the low level of lubricant. The data indicates that lubricant level within capsules has an influence on deposition profiles and amount of drug remaining in capsule and inhaler device after actuation. It is suggested lubricant levels greater than 60 mg/kg MO per capsule are required to minimise powder retention within capsules and maximise deposition profiles. AFM (atomic force microscopy) data suggest that internal surface roughness may be related with this phenomena. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  12. 77 FR 53892 - Determination That ALOXI (Palonosetron Hydrochloride) Capsules, 0.5 Milligram (Base), Were Not...

    Science.gov (United States)

    2012-09-04

    ...) Capsules, 0.5 Milligram (Base), Were Not Withdrawn From Sale for Reasons of Safety or Effectiveness AGENCY... determined that ALOXI (palonosetron hydrochloride (HCl)) Capsules, 0.5 milligram (mg) (base), were not... abbreviated new drug applications (ANDAs) for palonosetron HCl capsules, 0.5 mg (base), if all other legal and...

  13. 21 CFR 520.2345f - Tetracycline phosphate complex and sodium novobiocin capsules.

    Science.gov (United States)

    2010-04-01

    ... novobiocin capsules. 520.2345f Section 520.2345f Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... ANIMAL DRUGS § 520.2345f Tetracycline phosphate complex and sodium novobiocin capsules. (a) Specifications. Each capsule contains the equivalent of 60 milligrams of tetracycline hydrochloride and 60...

  14. 78 FR 1221 - Notice of Issuance of Final Determination Concerning Ponstel® (Mefenamic Acid) Capsules

    Science.gov (United States)

    2013-01-08

    ... (Mefenamic Acid) Capsules AGENCY: U.S. Customs and Border Protection, Department of Homeland Security. ACTION... acid) capsules. Based upon the facts presented, CBP has concluded in the final determination that India is the country of origin of the Ponstel (mefenamic acid) capsules for purposes of U.S. Government...

  15. 76 FR 59141 - Determination That LOXITANE (Loxapine Succinate) Capsules and Three Other Drug Products Were Not...

    Science.gov (United States)

    2011-09-23

    ... HUMAN SERVICES Food and Drug Administration Determination That LOXITANE (Loxapine Succinate) Capsules...., 417 Wakara Capsules, Way, Suite 100, Equivalent to (EQ) Salt Lake City, UT 5 milligram (mg) 84108...) Inc., 340 Kingsland Capsule, 200 mg. St., Nutley, NJ 07110. FDA has reviewed its records and, under...

  16. 77 FR 41412 - Determination That CHLOROMYCETIN (Chloramphenicol) Capsules, 250 Milligrams, Were Withdrawn From...

    Science.gov (United States)

    2012-07-13

    ... HUMAN SERVICES Food and Drug Administration Determination That CHLOROMYCETIN (Chloramphenicol) Capsules... CHLOROMYCETIN (chloramphenicol) Capsules, 250 milligrams (mg), were withdrawn from sale for reasons of safety or... chloramphenicol capsules, 250 mg. FOR FURTHER INFORMATION CONTACT: Nikki Mueller, Center for Drug Evaluation and...

  17. Elastic Changes of Capsule in a Rat Knee Contracture Model Assessed by Scanning Acoustic Microscopy

    Science.gov (United States)

    Hagiwara, Y.; Chimoto, E.; Ando, A.; Saijo, Y.; Itoi, E.

    Sound speed of a capsule in a rat knee contracture model was measured by scanning acoustic microscopy. There was no statistical significant difference in the anterior capsule compared with the control group. However, the sound speed of the posterior capsule was significantly greater compared with the control group after prolonged immobilization.

  18. Les Habitats: Culture Capsules in English for Use in Beginning French Classes.

    Science.gov (United States)

    Hofts, Jan; And Others

    Eight culture capsules describing various aspects of French housing are presented. Each capsule includes a French-American contrast and gives ideas for classroom presentation and student activities. The capsules deal with: le logement, les immeubles, les exterieurs, la minuterie, les portes, la salle de bain, le refrigerateur, and culture grains…

  19. Self collision avoidance for humanoids using circular and elliptical capsule bounding volumes

    CSIR Research Space (South Africa)

    Dube, C

    2013-09-01

    Full Text Available . The humanoid body is modeled using elliptical capsules, while the moving segments, i.e. arms and legs, of the humanoid are modeled using circular capsules. The self collision distance between two capsules is computed and used to generate self collision free...

  20. Fabrication, characterization and evaluation of bacterial cellulose-based capsule shells for oral drug delivery

    DEFF Research Database (Denmark)

    Ullah, Hanif; Badshah, Munair; Mäkilä, Ermei

    2017-01-01

    Bacterial cellulose (BC) was investigated for the first time for the preparation of capsule shells for immediate and sustained release of drugs. The prepared capsule shells were characterized using X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The BC...... to gelatin capsules with both immediate and sustained drug release properties depending upon the compositions of the encapsulated materials....