WorldWideScience

Sample records for capsule pipelines

  1. Pneumatic Capsule Pipeline

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Pneumatic capsule pipeline (PCP) uses wheeled capsules (vehicles) to carry cargoes through a pipeline filled with air. Modern large diameter PCP systems utilize through flow booster pumps, also known as jet pump injectors. These create the pressure differentials required to propel multiple capsules through a pipeline, while allowing both terminals at atmospheric pressure. This is done by placing a booster pump midway along the pipeline, and designing it in such a way that capsules can bypass ...

  2. Pneumatic capsule pipeline system

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, J.; Partyka, J.; Rudd, L. [Laurentian Univ., School of Engineering, Sudbury, ON (Canada)

    2001-03-01

    With the rising cost of transporting ores and concentrates, alternatives to the traditional means of transportation by rail, trucks and hoists are being actively sought, as a means of reducing operating costs. Pneumatic encapsulated pipeline (PCP) transportation of raw, processed, or waste materials is being looked upon as a potentially viable alternative for material handling in the mining industry. There are several operating PCP systems in Europe and in Japan, although there are as yet no similar applications in North America. To evaluate the viability of pneumatic capsule pipeline systems, a 600 mm diameter, 70 m long pilot PCP plant, made of rigid fibreglass, was constructed at Laurentian University and several tests have already been conducted. It was found that any bulk material can be transported by PCP safely, with relatively small amounts of power, over long distances, and at a significantly reduced cost, while maintaining complete control. Both underground as well as surface applications appear to be viable. This paper concentrates on the results of experiments designed to test the energy requirements of a PCP system. Future studies should focus on exploring and improving the ability of PCP systems to transport vertically which would be a great advantage to hauling ore from underground mines to the surface. 3 refs., 2 tabs., 14 figs.

  3. Optimal Design of Capsule Transporting Pipeline carrying Spherical Capsules

    Science.gov (United States)

    Asim, Taimoor; Mishra, Rakesh; Ubbi, Kuldip

    2012-05-01

    A capsule pipeline transports material or cargo in capsules propelled by fluid flowing through a pipeline. The cargo may either be contained in capsules (such as wheat enclosed inside sealed cylindrical containers), or may itself be the capsules (such as coal compressed into the shape of a cylinder or sphere). As the concept of capsule transportation is relatively new, the capsule pipelines need to be designed optimally for commercial viability. An optimal design of such a pipeline would have minimum pressure drop due to the presence of the solid medium in the pipeline, which corresponds to minimum head loss and hence minimum pumping power required to drive the capsules and the transporting fluid. The total cost for the manufacturing and maintenance of such pipelines is yet another important variable that needs to be considered for the widespread commercial acceptance of capsule transporting pipelines. To address this, the optimisation technique presented here is based on the least-cost principle. Pressure drop relationships have been incorporated to calculate the pumping requirements for the system. The maintenance and manufacturing costs have been computed separately to analyse their effects on the optimisation process. A design example has been included to show the usage of the model presented. The results indicate that for a specific throughput, there exists an optimum diameter of the pipeline for which the total cost for the piping system is at its minimum.

  4. Optimisation of a Horizontal Capsule Transporting Pipeline carrying Cylindrical Capsules

    Science.gov (United States)

    Asim, Taimoor; Mishra, Rakesh; Kollar, Laszlo; Ubbi, Kuldip

    2012-05-01

    Pipelines carrying fluids and slurries are quite common. The third-generation pipelines carrying spherical or cylindrical capsules (hollow containers) filled with minerals or other materials including hazardous liquids are rather a new concept. These pipelines need to be designed optimally for commercial viability. An optimal design of such a pipeline results in minimum pressure drop in the pipeline. This corresponds to minimum head loss and hence minimum pumping power required to drive the capsules and the transporting fluid. This study uses a rigorous approach to predict pumping cost based on Computational Fluid Dynamics (CFD) and hence optimize the design of the capsule transporting pipelines. Pressure drop relationship developed has been incorporated to calculate the pumping requirements for the system. Based on the least-cost principle, a methodology has been developed for the determination of the optimal diameter of cylindrical capsule carrying hydraulic pipeline. This procedure can be applied to obtain the optimal size of the capsule pipeline for minimum pumping and capital costs.

  5. Transport of solid commodities via freight pipeline: freight pipeline technology. Volume II. First year final report. [Slurry, pneumatic, pneumo-capsule, and hydro-capsule

    Energy Technology Data Exchange (ETDEWEB)

    Zandi, I.; Gimm, K.K.

    1976-07-01

    In order to determine the feasibility of pipeline as an intercity freight transportation mode, it was necessary to examine its technological feasibility and reliability. This report describes the technology of the major generic freight pipelines in terms of both historical and current trends and operations. Additionally, it presents a state-of-the-art review of calculating energy requirements of various generic freight pipelines. It was concluded that slurry and pneumatic pipelines are technologically feasible and reliable. There are many commercial installations of both types operating around the world. Based on European experience with pneumo-capsule pipelines for mail delivery and Russian gravel- and sand-transport installations, it appears that a pneumo-capsule pipeline is a technologically feasible and operationally reliable mode for transport of solids. Since no commercial pneumo-capsule pipeline installations yet exist in the U.S., it seems desirable that a service demonstration of the advantages and feasibility of this mode of transport be undertaken to attract the shippers' confidence. Hydro-capsule pipelines are technologically feasible, but its reliability within a commercial environment remains to be tested.

  6. Capsule Pipeline Research Center. 3-year Progress report, September 1, 1993--August 31, 1994

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    The Capsule Pipeline Research Center is devoted to performing research in capsule pipelines so that this emerging technology can be developed for early use to transport solids including coal, grain, other agricultural products, solid wastes, etc. Important research findings and accomplishments during the first-three years include: success in making durable binderless coal logs by compaction, success in underwater extrusion of binderless coal logs, success in compacting and extruding coal logs with less than 3% hydrophobic binder at room temperature, improvement in the injection system and the pump-bypass scheme, advancement in the state-of-the-art of predicting the energy loss (pressure drop) along both stationary and moving capsules, demonstrated the effectiveness of using polymer for drag reduction in CLP, demonstrated the influence of zeta potential on coal log fabrication, improved understanding of the water absorption properties of coal logs, better understanding of the mechanism of coal log abrasion (wear), completed a detailed economic evaluation of the CLP technology and compared coal transportation cost by CLP to that by rail, truck and slurry pipelines, and completion of several areas of legal research. The Center also conducted important technology transfer activities including workshops, work sessions, company seminars, involvement of companies in CLP research, issuance of newsletters, completion of a video tape on CLP, and presentation of research findings at numerous national and international meetings.

  7. Capsule Pipeline Research Center. 3-year Progress report, September 1, 1993--August 31, 1994

    International Nuclear Information System (INIS)

    The Capsule Pipeline Research Center is devoted to performing research in capsule pipelines so that this emerging technology can be developed for early use to transport solids including coal, grain, other agricultural products, solid wastes, etc. Important research findings and accomplishments during the first-three years include: success in making durable binderless coal logs by compaction, success in underwater extrusion of binderless coal logs, success in compacting and extruding coal logs with less than 3% hydrophobic binder at room temperature, improvement in the injection system and the pump-bypass scheme, advancement in the state-of-the-art of predicting the energy loss (pressure drop) along both stationary and moving capsules, demonstrated the effectiveness of using polymer for drag reduction in CLP, demonstrated the influence of zeta potential on coal log fabrication, improved understanding of the water absorption properties of coal logs, better understanding of the mechanism of coal log abrasion (wear), completed a detailed economic evaluation of the CLP technology and compared coal transportation cost by CLP to that by rail, truck and slurry pipelines, and completion of several areas of legal research. The Center also conducted important technology transfer activities including workshops, work sessions, company seminars, involvement of companies in CLP research, issuance of newsletters, completion of a video tape on CLP, and presentation of research findings at numerous national and international meetings

  8. Pipeline transport of fossile fuels

    OpenAIRE

    Vlasák, Pavel

    2003-01-01

    The paper deals with hydraulic pipeline transport of fossil fuels. A general analysis of coal and heavy viscous oil pipelining systems is introduced and pipeline transport of concentrated coal-water slurry, coal-water fuel, coal pipelining in other than water carrier liquid (e.g. methanol) and capsule pipeline transport (coal-log pipelining) is described.

  9. Capsule endoscopy

    DEFF Research Database (Denmark)

    Skovsen, Anders Peter; Burcharth, Jakob; Burgdorf, Stefan Kobbelgaard

    2013-01-01

    of capsule retention, especially in patients with known or suspected Crohn's disease, due to the propensity of Crohn's disease to form stenosis of the bowel. In cases where a stenosis is suspected, it is warranted to perform a patency capsule swallow before subjecting the patient to a capsule endoscopy....

  10. Pipeline engineering

    CERN Document Server

    Liu, Henry

    2003-01-01

    PART I: PIPE FLOWSINTRODUCTIONDefinition and Scope Brief History of PipelinesExisting Major PipelinesImportance of PipelinesFreight (Solids) Transport by PipelinesTypes of PipelinesComponents of PipelinesAdvantages of PipelinesReferencesSINGLE-PHASE INCOMPRESSIBLE NEWTONIAN FLUIDIntroductionFlow RegimesLocal Mean Velocity and Its Distribution (Velocity Profile)Flow Equations for One-Dimensional AnalysisHydraulic and Energy Grade LinesCavitation in Pipeline SystemsPipe in Series and ParallelInterconnected ReservoirsPipe NetworkUnsteady Flow in PipeSINGLE-PHASE COMPRESSIBLE FLOW IN PIPEFlow Ana

  11. Capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Miguel Mu(n)oz-Navas

    2009-01-01

    Capsule endoscopy (CE) is a simple, safe, non-invasive, reliable technique, well accepted and tolerated by the patients, which allows complete exploration of the small intestine. The advent of CE in 2000 has dramatically changed the diagnosis and management of many diseases of the small intestine, such as obscure gastrointestinal bleeding, Crohn's disease, small bowel tumors, polyposis syndromes, etc. CE has become the gold standard for the diagnosis of most diseases of the small bowel. Lately this technique has also been used for esophageal and colonic diseases.

  12. Colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Ana Borda; Miguel Mu(n)oz-Navas

    2008-01-01

    Wireless capsule endoscopy has become the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Clinical trials results have shown that colon capsule endoscopy is feasible,accurate and safe in patients suffering from colonic diseases.It could be a good alternative in patients refusing conventional colonoscopy or when it is contraindicated.Upcoming studies are needed to demonstrate its utilty for colon cancer screening and other indications such us ulcerative colitis.Comparative studies including both conventional and virtual colonoscopy are also required.

  13. Esophageal capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Ignacio Fernandez-Urien; Cristina Carretero; Raul Armendariz; Miguel Mu(n)oz-Navas

    2008-01-01

    Capsule endoscopy is now considered as the first imaging tool for small bowel examination.Recently,new capsule endoscopy applications have been developed,such as esophageal capsule endoscopy and colon capsule endoscopy.Esophageal capsule endoscopy in patients with suspected esophageal disorders is feasible and safe,and could be also an alternative procedure in those patients refusing upper endoscopy.Although large-scale studies are needed to confirm its utility in GERD and cirrhotic patients,current results are encouraging and open a new era in esophageal examination.

  14. Leadership Pipeline

    DEFF Research Database (Denmark)

    Elmholdt, Claus Westergård

    2012-01-01

    Artiklen analyserer grundlaget for Leadership Pipeline modellen med henblik på en vurdering af substansen bag modellen, og perspektiverne for generalisering af modellen til en dansk organisatorisk kontekst.......Artiklen analyserer grundlaget for Leadership Pipeline modellen med henblik på en vurdering af substansen bag modellen, og perspektiverne for generalisering af modellen til en dansk organisatorisk kontekst....

  15. Leadership Pipeline

    DEFF Research Database (Denmark)

    Elmholdt, Claus Westergård

    2013-01-01

    I artiklen undersøges det empiriske grundlag for Leader- ship Pipeline. Først beskrives Leadership Pipeline modellen om le- delsesbaner og skilleveje i opadgående transitioner mellem orga- nisatoriske ledelsesniveauer (Freedman, 1998; Charan, Drotter and Noel, 2001). Dernæst sættes fokus på det...... forholdet mellem kontinuitet- og diskontinuitet i ledel- seskompetencer på tværs af organisatoriske niveauer præsenteres og diskuteres. Afslutningsvis diskuteres begrænsningerne i en kompetencebaseret tilgang til Leadership Pipeline, og det foreslås, at succesfuld ledelse i ligeså høj grad afhænger af...

  16. Management of adhesive capsulitis

    OpenAIRE

    Neviaser, Andrew

    2015-01-01

    Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive cri...

  17. Capsule contraction syndrome

    Directory of Open Access Journals (Sweden)

    Mesut COŞKUN

    2009-06-01

    Full Text Available Capsule contraction syndrome occurs after fibrous metaplasia of lens proteins that leads to capsular bag contraction. Excessive front capsular wrinkling is seen in capsule contraction syndrome and there is an imbalance between powers supplying capsular integrity. This situation leads to zonular weakness. Capsule contraction syndrome is associated with pseudoexfoliation, older age, uveitis, pars planitis and myotonic muscular dystrophy. In order to decrease the risk of capsule contraction syndrome, front capsulerhexis area should be open as 5.5-6 mm diameter and a curysoft intraocular lens should be used. In order to prevent lens epithelial proliferation and metaplasia, lens epithelial cells at inferior surface of front capsule should be aspirated carefully. If postoperative capsular contraction detected, front capsulotomy should be performed by Nd-YAG laser at postoperative 2 to 3 weeks. In patients that Nd-YAG laser is unsuccessful, capsular tension should be decreased by surgical microincisions. In present study, we evaluated etiology, prevention and management of capsule contraction syndrome in the light of actual literature knowledge.

  18. Pipeline Power

    OpenAIRE

    Hubert, Franz; Cobanli, Onur

    2012-01-01

    We use cooperative game theory to analyze the impact of three controversial pipeline projects on the power structure in the Eurasian trade of natural gas. Two of them, Nord Stream and South Stream, allow Russian gas to bypass transit countries, Ukraine and Belarus. Nord Stream's strategic value turns out to be huge, justifying the high investment cost for Germany and Russia. The additional leverage obtained through South Stream, in contrast, appears small. The third project, Nabucco, aims at ...

  19. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  20. Wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    A Mata; J Llach; JM Bordas

    2008-01-01

    Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without external wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleeding, Crohn's disease and gastrointestinal polyposis syndromes with promising results. Studies on other pathologies (I.e. Small bowel tumour, celiac disease) are under evaluation to define the role of this technique.

  1. Management of adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Stupay KL

    2015-08-01

    Full Text Available Kristen L Stupay,1 Andrew S Neviaser2 1Tulane University School of Medicine, New Orleans, LA, USA; 2George Washington University Medical Faculty Associates, Washington, DC, USA Abstract: Adhesive capsulitis of the shoulder is a condition of capsular contracture that reduces both active and passive glenohumeral motion. The cause of adhesive capsulitis is not known but it is strongly associated with endocrine abnormalities such as diabetes. Diverse terminology and the absence of definitive criteria for diagnosis make evaluating treatment modalities difficult. Many treatment methods have been reported, most with some success, but few have been proved to alter the natural course of this disease. Most afflicted patients will achieve acceptable shoulder function without surgery. Those who remain debilitated after 8–12 months are reasonable candidates for invasive treatments. Here, the various treatment methods and the data to support their use are reviewed. Keywords: frozen shoulder, stiff shoulder, periarthritis, painful shoulder 

  2. Capsule-train stability

    Science.gov (United States)

    Bryngelson, Spencer H.; Freund, Jonathan B.

    2016-07-01

    Elastic capsules flowing in small enough tubes, such as red blood cells in capillaries, are well known to line up into regular single-file trains. The stability of such trains in somewhat wider channels, where this organization is not observed, is studied in a two-dimensional model system that includes full coupling between the viscous flow and suspended capsules. A diverse set of linearly amplifying disturbances, both long-time asymptotic (modal) and transient (nonmodal) perturbations, is identified and analyzed. These have a range of amplification rates and their corresponding forms are wavelike, typically dominated by one of five principal perturbation classes: longitudinal and transverse translations, tilts, and symmetric and asymmetric shape distortions. Finite-amplitude transiently amplifying perturbations are shown to provide a mechanism that can bypass slower asymptotic modal linear growth and precipitate the onset of nonlinear effects. Direct numerical simulations are used to verify the linear analysis and track the subsequent transition of the regular capsule trains into an apparently chaotic flow.

  3. Underground pipeline corrosion

    CERN Document Server

    Orazem, Mark

    2014-01-01

    Underground pipelines transporting liquid petroleum products and natural gas are critical components of civil infrastructure, making corrosion prevention an essential part of asset-protection strategy. Underground Pipeline Corrosion provides a basic understanding of the problems associated with corrosion detection and mitigation, and of the state of the art in corrosion prevention. The topics covered in part one include: basic principles for corrosion in underground pipelines, AC-induced corrosion of underground pipelines, significance of corrosion in onshore oil and gas pipelines, n

  4. 77 FR 70543 - Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory...

    Science.gov (United States)

    2012-11-26

    ... for natural gas pipelines and for hazardous liquid pipelines. Both committees were established under... TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory Committee AGENCY: Pipeline and...

  5. 78 FR 70623 - Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory...

    Science.gov (United States)

    2013-11-26

    ... gas pipelines and for hazardous liquid pipelines. Both committees were established under the Federal... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory Committee AGENCY: Pipeline and Hazardous...

  6. Capsule endoscopy in celiac disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endoscopy; however, indications are expanding and a small number of preliminary reports have been presented concerning the role of video capsule endoscopy in the diagnosis of celiac disease. The purpose of this review is to update the current knowledge and to hypothesize on future perspectives of the use of video capsule endoscopy in patients with celiac disease.

  7. 75 FR 13342 - Pipeline Safety: Workshop on Distribution Pipeline Construction

    Science.gov (United States)

    2010-03-19

    ... Statement in the Federal Register published April 11, 2000 (65 FR 19477). Information on Services for... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Workshop on Distribution Pipeline Construction AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice...

  8. Magnetism in metal-organic capsules

    Energy Technology Data Exchange (ETDEWEB)

    Atwood, Jerry L.; Brechin, Euan K; Dalgarno, Scott J.; Inglis, Ross; Jones, Leigh F.; Mossine, Andrew; Paterson, Martin J.; Power, Nicholas P.; Teat, Simon J.

    2010-01-07

    Nickel and cobalt seamed metal-organic capsules have been isolated and studied using structural, magnetic and computational approaches. Antiferromagnetic exchange in the Ni capsule results from coordination environments enforced by the capsule framework.

  9. Wireless capsule endo bronchoscopy

    Directory of Open Access Journals (Sweden)

    Baratz DM

    2014-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Case Presentation History of Present Illness A 67 year-old man presents 10 days after swallowing a capsule endoscopy camera that was never retrieved. The wireless capsule was swallowed asymptomatically for evaluation of heme positive stools after negative upper and lower endoscopies. Patient noted that the evening after swallowing the camera he developed mild shortness of breath and cough. The cough and shortness of breath were persistent and worsened while lying down and when moving positions. He denied prior issues with swallowing or aspiration. Review of Systems Negative other than what is noted above. PMH, SH, and FH Past medical history: coronary artery disease, peripheral vascular disease, hyperlipidemia Surgical history: femoral-popliteal bypass, previous shoulder and back surgery Social history: 1 pack/day of cigarettes for 50 years, prior alcohol usage but not current, no illicit drugs Family history: no pulmonary diseases Physical Exam Vital signs: temperature 36.7º C, heart rate 86 beats per minute ...

  10. 77 FR 19799 - Pipeline Safety: Pipeline Damage Prevention Programs

    Science.gov (United States)

    2012-04-02

    ... Administration 49 CFR Parts 196 and 198 Pipeline Safety: Pipeline Damage Prevention Programs; Proposed Rule #0;#0... Pipeline Safety: Pipeline Damage Prevention Programs AGENCY: Pipeline and Hazardous Materials Safety... criteria and procedures for determining the adequacy of state pipeline excavation damage prevention...

  11. Quantitative measurements in capsule endoscopy.

    Science.gov (United States)

    Keuchel, M; Kurniawan, N; Baltes, P; Bandorski, D; Koulaouzidis, A

    2015-10-01

    This review summarizes several approaches for quantitative measurement in capsule endoscopy. Video capsule endoscopy (VCE) typically provides wireless imaging of small bowel. Currently, a variety of quantitative measurements are implemented in commercially available hardware/software. The majority is proprietary and hence undisclosed algorithms. Measurement of amount of luminal contamination allows calculating scores from whole VCE studies. Other scores express the severity of small bowel lesions in Crohn׳s disease or the degree of villous atrophy in celiac disease. Image processing with numerous algorithms of textural and color feature extraction is further in the research focuses for automated image analysis. These tools aim to select single images with relevant lesions as blood, ulcers, polyps and tumors or to omit images showing only luminal contamination. Analysis of motility pattern, size measurement and determination of capsule localization are additional topics. Non-visual wireless capsules transmitting data acquired with specific sensors from the gastrointestinal (GI) tract are available for clinical routine. This includes pH measurement in the esophagus for the diagnosis of acid gastro-esophageal reflux. A wireless motility capsule provides GI motility analysis on the basis of pH, pressure, and temperature measurement. Electromagnetically tracking of another motility capsule allows visualization of motility. However, measurement of substances by GI capsules is of great interest but still at an early stage of development. PMID:26299419

  12. Trace Software Pipelining

    Institute of Scientific and Technical Information of China (English)

    王剑; AndreasKrall; 等

    1995-01-01

    Global software pipelining is a complex but efficient compilation technique to exploit instruction-level parallelism for loops with branches.This paper presents a novel global software pipelining technique,called Trace Software Pipelining,targeted to the instruction-level parallel processors such as Very Long Instruction Word (VLIW) and superscalar machines.Trace software pipelining applies a global code scheduling technique to compact the original loop body.The resulting loop is called a trace software pipelined (TSP) code.The trace softwrae pipelined code can be directly executed with special architectural support or can be transformed into a globally software pipelined loop for the current VLIW and superscalar processors.Thus,exploiting parallelism across all iterations of a loop can be completed through compacting the original loop body with any global code scheduling technique.This makes our new technique very promising in practical compilers.Finally,we also present the preliminary experimental results to support our new approach.

  13. AN ELECTROMAGNETIC PNEUMO CAPSULE SYSTEM FOR CONVEYING MINERALS AND MINE WASTES

    Energy Technology Data Exchange (ETDEWEB)

    Henry Liu; Charles W. Lenau

    2005-03-01

    The purpose of this project is to investigate the technical and economic feasibility of using a new and advanced pneumatic capsule pipeline (PCP) system for transporting minerals and mine wastes. The new system is different from conventional PCPs in two main respects: (1) it uses linear induction motors (LIMs) instead of blowers (fans) at the inlet of the pipeline to drive (pump) the capsules and the air through the pipeline; and (2) the capsules in the PCP have steel wheels running on steel rails as opposed to capsules in conventional systems, which use wheels with rubber tires running inside a pipe without rail. The advantage of using LIM pump instead of blower is that the former is non-intrusive and hence does not block the passage of capsules, enabling the system to run continuously without having to make the capsules bypass the pump. This not only simplifies the system but also enables the system to achieve much larger cargo throughput than that of PCPs using blowers, and use of LIMs as booster pumps which enables the system to have any length or to be used for transporting cargoes over practically any distance, say even one thousand kilometers or miles. An advantage of using steel wheels rolling on steel rails instead of using rubber tires rolling inside a pipeline is that the rolling friction coefficient and hence the use of energy is greatly reduced from that of conventional PCP systems. Moreover, rails enable easy control of capsule motion, such as switching capsules to a branch line by using railroad switching equipment. The advanced PCP system studied under this project uses rectangular conduits instead of circular pipe, having cross-sectional areas of 1 m by 1 m approximately. The system can be used for various transportation distances, and it can transport up to 50 million tonnes (metric tons) of cargo annually--the throughput of the largest mines in the world. Both an aboveground and an underground system were investigated and compared. The technical

  14. Adhesive capsulitis: a case report

    OpenAIRE

    Kazemi, Mohsen

    2000-01-01

    Adhesive capsulitis or frozen shoulder is an uncommon entity in athletes. However, it is a common cause of shoulder pain and disability in the general population. Although it is a self limiting ailment, its rather long, restrictive and painful course forces the affected person to seek treatment. Conservative management remains the mainstay treatment of adhesive capsulitis. This includes chiropractic manipulation of the shoulder, therapeutic modalities, mobilization, exercise, soft tissue ther...

  15. Pipelines on irregular seabed

    Energy Technology Data Exchange (ETDEWEB)

    Lund, S.; Gjertveit, E.

    1985-01-01

    From the Statpipe project in the North Sea a unique experience has been gained on the design and construction of pipelines on seabed with large irregularities of different types. The Statpipe pipeline system consists of 4 pipeline legs and totals 842 km subsea and 40 km onshore lines. Two pipelines are crossing the Norwegian Trench at about 300 m water depth. In the Statpipe project pre-lay intervention to prepare the seabed for pipelaying was only required for less than a 1 km rock outcrop section in the landfall area. The offshore pipelines cross large areas of pockmarks and iceberg ploughmarks. However, after an extensive design effort a routing was found which avoided pre-lay intervention and limited the post-lay intervention work. Grout bag supports were installed underneath the most severe pipeline spans as a temporary measure, while permanent span correction was performed by trenching and gravel dumping. The above methods proved adequate for the largest ploughmark spans with height under the pipeline up to 3.3 m (moranic material) and pockmark spans in soft soil with height up to 6 m (trenching only). For pipelines in landfall areas, where the seabed is highly irregular due to rock outcrops, various construction methods are at disposal. The Statpipe project used a subsea bridge to span the irregularities, while another pipeline project (Oseberg) is constructing a subsea floor tunnel for later pull-in of the pipeline through a sealing plug at an offshore point.

  16. ALMA Pipeline: Current Status

    Science.gov (United States)

    Shinnaga, H.; Humphreys, E.; Indebetouw, R.; Villard, E.; Kern, J.; Davis, L.; Miura, R. E.; Nakazato, T.; Sugimoto, K.; Kosugi, G.; Akiyama, E.; Muders, D.; Wyrowski, F.; Williams, S.; Lightfoot, J.; Kent, B.; Momjian, E.; Hunter, T.; ALMA Pipeline Team

    2015-12-01

    The ALMA Pipeline is the automated data reduction tool that runs on ALMA data. Current version of the ALMA pipeline produces science quality data products for standard interferometric observing modes up to calibration process. The ALMA Pipeline is comprised of (1) heuristics in the form of Python scripts that select the best processing parameters, and (2) contexts that are given for book-keeping purpose of data processes. The ALMA Pipeline produces a "weblog" that showcases detailed plots for users to judge how each step of calibration processes are treated. The ALMA Interferometric Pipeline was conditionally accepted in March 2014 by processing Cycle 0 and Cycle 1 data sets. From Cycle 2, ALMA Pipeline is used for ALMA data reduction and quality assurance for the projects whose observing modes are supported by the ALMA Pipeline. Pipeline tasks are available based on CASA version 4.2.2, and the first public pipeline release called CASA 4.2.2-pipe has been available since October 2014. One can reduce ALMA data both by CASA tasks as well as by pipeline tasks by using CASA version 4.2.2-pipe.

  17. Deformability-based capsule sorting

    Science.gov (United States)

    Le Goff, Anne; Munier, Nadege; Maire, Pauline; Edwards-Levy, Florence; Salsac, Anne-Virginie

    2015-11-01

    Many microfluidic devices have been developed for cancer diagnosis applications, most of which relying on costly antibodies. Since some cancer cells display abnormal mechanical properties, new sorting tools based on mechanical sensing are of particular interest. We present a simple, passive pinched flow microfluidic system for capsule sorting. The device consists of a straight microchannel containing a cylindrical obstacle. Thanks to a flow-focusing module placed at the channel entrance, capsules arrive well-centered in the vicinity of the obstacle. Pure size-sorting can be achieved at low shear rate. When increasing the shear rate, capsules are deformed in the narrow space between the pillar and the wall. The softer the capsule, the more tightly it wraps around the obstacle. After the obstacle, streamlines diverge, allowing for the separation between soft capsules, that follow central streamlines, and stiff capsules, that drift away from the obstacle with a wider angle. This proves that we have developed a flexible multipurpose sorting microsystem based on a simple design.

  18. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  19. Alaska highway pipeline inquiry

    Energy Technology Data Exchange (ETDEWEB)

    Lysyk, K.M.; Bohmer, E.E.; Phelps, W.L.

    1977-01-01

    A public enquiry was held to determine the social and economic impacts associated with the proposed Alaska Highway pipeline. The pipeline was proposed to carry natural gas from Prudhoe Bay to the continental United States. The pipeline would follow the trans-Alaskan pipeline to Fairbanks, and follow the Alaska Highway through southern Yukon into northern British Columbia. The 48 inch pipe would operate at a pressure of 1,260 psi and would carry 2.4 billion cubic feet of gas per day, and could operate at that level for at least 25 years. Issues considered included alternative routes, employment and training, economic impact, social impact, the Yukon Indian land claim, the Dempster Lateral pipeline, planning and regulation, and compensation. The enquiry concluded that the government of Canada should not give approval in principle to the proposed pipeline through the southern Yukon without resolving the issues of an advanced payment towards the settlement of the Yukon Indian land claim, of compensation from the pipeline company, the establishment of a planning and control agency, and the deferral of the commencement of construction of the pipeline. 8 figs.

  20. Slurry pipeline design approach

    Energy Technology Data Exchange (ETDEWEB)

    Betinol, Roy; Navarro R, Luis [Brass Chile S.A., Santiago (Chile)

    2009-12-19

    Compared to other engineering technologies, the design of a commercial long distance Slurry Pipeline design is a relatively new engineering concept which gained more recognition in the mid 1960 's. Slurry pipeline was first introduced to reduce cost in transporting coal to power generating units. Since then this technology has caught-up worldwide to transport other minerals such as limestone, copper, zinc and iron. In South America, the use of pipeline is commonly practiced in the transport of Copper (Chile, Peru and Argentina), Iron (Chile and Brazil), Zinc (Peru) and Bauxite (Brazil). As more mining operations expand and new mine facilities are opened, the design of the long distance slurry pipeline will continuously present a commercially viable option. The intent of this paper is to present the design process and discuss any new techniques and approach used today to ensure a better, safer and economical slurry pipeline. (author)

  1. Slurry pipeline hydrostatic testing

    Energy Technology Data Exchange (ETDEWEB)

    Betinol, Roy G.; Navarro Rojas, Luis Alejandro [BRASS Chile S.A., Santiago (Chile)

    2009-07-01

    The transportation of concentrates and tailings through long distance pipeline has been proven in recent years to be the most economic, environmentally friendly and secure means of transporting of mine products. This success has led to an increase in the demand for long distance pipeline throughout the mining industry. In year 2007 alone, a total of over 500 km of pipeline has been installed in South America alone and over 800 km are in the planning stages. As more pipelines are being installed, the need to ensure its operating integrity is ever increasing. Hydrostatic testing of long distance pipeline is one of the most economical and expeditious way to proving the operational integrity of the pipe. The intent of this paper is to show the sound reasoning behind construction hydro testing and the economic benefit it presents. It will show how hydro test pressures are determined based on ASME B31.11 criteria. (author)

  2. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  3. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  4. Capsule endoscopy in pediatric patients

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Wireless capsule endoscope (WCE) for the investigation of the small bowel is an approved technique both in adults and children (more than 10 years old). The present review provides data on the indications, diagnostic yield, adverse events and limitations of the WCE technique in children and tries to predict the future of WCE usage in this population of patients.

  5. Pipeline coating comparison methods for northern pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Singh, P. [Shaw Pipe Protection, Calgary, AB (Canada); Purves, G.A. [Cimarron Engineering Ltd., Calgary, AB (Canada)

    2004-07-01

    Two high-quality pipe coatings designed for northern environments were compared for their relative costs and suitability for the conditions that will be encountered in the field. Coating selection should consider local conditions to achieve the optimum life-cycle costs for the system. Some of the key factors affecting the integrity of the protective coating on a pipe include the effects of cold temperature and soil types. In this study, both Fusion Bonded Epoxy (FBE) and High Performance Composite Coatings (HPCC) were evaluated for an entire pipeline installation in a northern environment, from the coating plant to the pipe trench. The evaluation focused on the advantages of better abrasion resistance of the HPCC coating. This was compared against the incremental cost of HPCC coating over FBE on large diameter NPS 30 to NPS 48 pipelines. The following parameters influenced the choice of coating: storage, transportation and handling; bending ability under cold weather conditions; pipe installation and backfilling; weld joint coatings; coating repair and cathodic protection and pipeline integrity. Some of the construction costs that are indirectly affected by the choice of pipe coating include right-of-way preparation and restoration; trenching; supervision, service and downtime and specialist crossings. It was concluded that HPCC has better resistance to abrasion than FBE and is more flexible in extremely cold temperatures. Standard FBE is about 10 per cent less expensive than HPCC. In general HPCC will require less coating protection than FBE, depending on site conditions. 3 refs., 18 tabs., 8 figs.

  6. Family love time capsule preview

    CERN Document Server

    Musgrave, Jim

    2015-01-01

    Create your own family time capsule online using EMRE Publishing's ePub3 Creator Studio. With our storage plans, your family videos, music playlists and mysteries can be preserved for coming generations to add to, embellish, and communicate using our Family Forum inside the Embellisher eReader for multimedia ""enhanced"" eBooks. Just like the ""American Sniper"" enhanced eBook, you can pay tribute to your fallen heroes and other family members who have distinguished themselves in life.

  7. 77 FR 2126 - Pipeline Safety: Implementation of the National Registry of Pipeline and Liquefied Natural Gas...

    Science.gov (United States)

    2012-01-13

    ... Registry of Pipeline and Liquefied Natural Gas Operators AGENCY: Pipeline and Hazardous Materials Safety... 72878), titled: ``Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements... registry of pipeline and liquefied natural gas operators. FOR FURTHER INFORMATION CONTACT: Jamerson...

  8. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Science.gov (United States)

    2010-01-26

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines AGENCY: Pipeline and Hazardous Materials Safety Administration; DOT. ACTION: Notice; Issuance of Advisory Bulletin. SUMMARY: The Pipeline and Hazardous Materials Safety Administration (PHMSA) is...

  9. 77 FR 61825 - Pipeline Safety: Notice of Public Meeting on Pipeline Data

    Science.gov (United States)

    2012-10-11

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Notice of Public Meeting on Pipeline Data AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice of public meeting. SUMMARY: PHMSA and the National Association of Pipeline Safety...

  10. 77 FR 31827 - Pipeline Safety: Pipeline Damage Prevention Programs

    Science.gov (United States)

    2012-05-30

    ... Safety: Pipeline Damage Prevention Programs AGENCY: Pipeline and Hazardous Materials Safety... excavation damage prevention law enforcement programs; establish an administrative process for making... excavation damage prevention law enforcement programs; and establish the adjudication process...

  11. Pipeline rehabilitation planning

    Energy Technology Data Exchange (ETDEWEB)

    Palmer-Jones, Roland; Hopkins, Phil; Eyre, David [PENSPEN (United Kingdom)

    2005-07-01

    An operator faced with an onshore pipeline that has extensive damage must consider the need for rehabilitation, the sort of rehabilitation to be used, and the rehabilitation schedule. This paper will consider pipeline rehabilitation based on the authors' experiences from recent projects, and recommend a simple strategy for planning pipeline rehabilitation. It will also consider rehabilitation options: external re-coating; internal lining; internal painting; programmed repairs. The main focus will be external re-coating. Consideration will be given to rehabilitation coating types, including tape wraps, epoxy, and polyurethane. Finally it will discuss different options for scheduling the rehabilitation of corrosion damage including: the statistical comparison of signals from inspection pigs; statistical comparison of selected measurements from inspection pigs and other inspections; the use of corrosion rates estimated for the mechanisms and conditions; expert judgement. (author)

  12. Asymmetric Membrane Osmotic Capsules for Terbutaline Sulphate

    OpenAIRE

    Gobade, N. G.; Marina Koland; K H Harish

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist...

  13. 76 FR 53086 - Pipeline Safety: Safety of Gas Transmission Pipelines

    Science.gov (United States)

    2011-08-25

    .... On October 18, 2010 (75 FR 63774) PHMSA published an ANPRM titled ``Pipeline Safety: Safety of On... rules (65 FR 75378; 12/1/ 2000 and 67 FR 2136; 1/16/2002) requiring IM Programs for hazardous liquid pipeline operators. In 2003, similar IM regulations were enacted for gas pipelines (68 FR 69778;...

  14. China Petroleum Pipeline Bureau (CPP)

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ China Petroleum Pipeline Bureau (CPP), which belongs to China National Petroleum Corporation (CNPC), authorizes China Petroleum Pipeline Engineering Corporation (CPPE) a subsidiary of CPP, to perform Overseas Business on behalf of it.

  15. Regulation of capsule in Neisseria meningitidis.

    Science.gov (United States)

    Tzeng, Yih-Ling; Thomas, Jennifer; Stephens, David S

    2016-09-01

    Neisseria meningitidis, a devastating pathogen exclusive to humans, expresses capsular polysaccharides that are the major meningococcal virulence determinants and the basis for successful meningococcal vaccines. With rare exceptions, the expression of capsule (serogroups A, B, C, W, X, Y) is required for systemic invasive meningococcal disease. Changes in capsule expression or structure (e.g. hypo- or hyper-encapsulation, capsule "switching", acetylation) can influence immunologic diagnostic assays or lead to immune escape. The loss or down-regulation of capsule is also critical in meningococcal biology facilitating meningococcal attachment, microcolony formation and the carriage state at human mucosal surfaces. Encapsulated meningococci contain a cps locus with promoters located in an intergenic region between the biosynthesis and the conserved capsule transport operons. The cps intergenic region is transcriptionally regulated (and thus the amount of capsule expressed) by IS element insertion, by a two-component system, MisR/MisS and through sequence changes that result in post-transcriptional RNA thermoregulation. Reversible on-off phase variation of capsule expression is controlled by slipped strand mispairing of homo-polymeric tracts and by precise insertion and excision of IS elements (e.g. IS1301) in the biosynthesis operon. Capsule structure can be altered by phase-variable expression of capsular polymer modification enzymes or "switched" through transformation and homologous recombination of different polymerases. Understanding the complex regulation of meningococcal capsule has important implications for meningococcal biology, pathogenesis, diagnostics, current and future vaccine development and vaccine strategies. PMID:26089023

  16. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  17. Infrared thermographic pipeline leak detection systems for pipeline rehabilitation programs

    Science.gov (United States)

    Weil, Gary J.

    1998-03-01

    Computerized infrared thermographic pipeline inspection is now a refined and accurate process having been thoroughly proven to be an accurate, cost effective, and efficient technology for pipeline rehabilitation programs, during a 10 year development and testing process. The process has been used to test pipelines in chemical plants, water supply systems, steam lines, natural gas pipelines and sewer systems. Its non- contact, non-destructive ability to inspect large areas, from above ground, with 100% coverage and to locate subsurface leaks as well as the additional capability to locate voids and erosion areas surrounding pipelines, make its testing capabilities unique and highly desirable. This paper details the development of computerized infrared thermographic pipeline testing along with case histories illustrating its implementation problems and successes during various rehabilitation programs involving pipelines carrying water, gas, petroleum, and sewage.

  18. Sinopec: Pipeline Goes Ahead

    Institute of Scientific and Technical Information of China (English)

    Xie Ye

    2002-01-01

    @@ Asia's largest refinery, Sinopec Corp, will proceed with a 1,600-kilometre oil pipeline across southern provinces of China, although speculation continues to linger that the company will scrap the plan due to a postponement of the multi-million-dollar project.

  19. Transient cavitation in pipelines

    NARCIS (Netherlands)

    Kranenburg, C.

    1974-01-01

    The aim of the present study is to set up a one-dimensional mathematical model, which describes the transient flow in pipelines, taking into account the influence of cavitation and free gas. The flow will be conceived of as a three-phase flow of the liquid, its vapour and non-condensible gas. The wa

  20. Orchestrator Telemetry Processing Pipeline

    Science.gov (United States)

    Powell, Mark; Mittman, David; Joswig, Joseph; Crockett, Thomas; Norris, Jeffrey

    2008-01-01

    Orchestrator is a software application infrastructure for telemetry monitoring, logging, processing, and distribution. The architecture has been applied to support operations of a variety of planetary rovers. Built in Java with the Eclipse Rich Client Platform, Orchestrator can run on most commonly used operating systems. The pipeline supports configurable parallel processing that can significantly reduce the time needed to process a large volume of data products. Processors in the pipeline implement a simple Java interface and declare their required input from upstream processors. Orchestrator is programmatically constructed by specifying a list of Java processor classes that are initiated at runtime to form the pipeline. Input dependencies are checked at runtime. Fault tolerance can be configured to attempt continuation of processing in the event of an error or failed input dependency if possible, or to abort further processing when an error is detected. This innovation also provides support for Java Message Service broadcasts of telemetry objects to clients and provides a file system and relational database logging of telemetry. Orchestrator supports remote monitoring and control of the pipeline using browser-based JMX controls and provides several integration paths for pre-compiled legacy data processors. At the time of this reporting, the Orchestrator architecture has been used by four NASA customers to build telemetry pipelines to support field operations. Example applications include high-volume stereo image capture and processing, simultaneous data monitoring and logging from multiple vehicles. Example telemetry processors used in field test operations support include vehicle position, attitude, articulation, GPS location, power, and stereo images.

  1. How helpful is capsule endoscopy to surgeons?

    Institute of Scientific and Technical Information of China (English)

    Osman Ersoy; Bulent Sivri; Yusuf Bayraktar

    2007-01-01

    Capsule endoscopy is a new technology that, for the first time, allows complete, non-invasive endoscopic imaging of the small bowel. The efficacy of capsule endoscopy in the diagnosis of suspected small bowel diseases has been established. Important applications for surgeons include observations of obscure gastrointestinal bleeding and small bowel neoplasms.

  2. The future of wireless capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.

  3. The NOAO Pipeline Data Manager

    Science.gov (United States)

    Hiriart, R.; Valdes, F.; Pierfederici, F.; Smith, C.; Miller, M.

    2004-07-01

    The Data Manager for NOAO Pipeline system is a set of interrelated components that are being developed to fulfill the pipeline system data needs. It includes: (1) management of calibration files (flat, bias, bad pixel mask and xtalk calibration data.); (2) management of the pipeline stages' configuration parameters; and (3) management of the pipeline processing historic information, for each of the data products generated by the pipeline. The Data Manager components uses a distributed, CORBA based architecture, providing a flexible and extensible object oriented framework, capable of accommodating the present and future pipeline data requirements. The Data Manager communicates with the pipeline modules, with internal and external databases, and with other NOAO systems such as the NOAO Archive and the NOAO Data Transport System.

  4. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  5. A Novel MagPipe Pipeline transportation system using linear motor drives

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J.R.; Montgomery, D.B.; Roderick, L. [Magplane Technology Inc., Littleton, MA (United States)

    2009-11-15

    A novel capsule pipeline transportation system using linear motor drives, called Magplane MagPipe, is under development with the intention to replace trucks and railways for hauling materials from the mine to the rail head, power plant, or processing plant with reduced operating cost and energy consumption. The initial demonstration of a MagPipe line in Inner Mongolia will be a 500-m-long double-pipe coal transport system with the design transportation capacity of 3 Mega-Mg per year. The pipeline consists of 6-m-long plastic pipe modules with an I-beam suspension system inside the pipe to carry sets of five coupled capsules. The pipe will also contain noncontinuous motor winding modules spaced at 50-m intervals. A set of Halbach-arrayed permanent magnets on the bottom of the capsules interact with the linear motor windings to provide propulsion. The motor is driven by variable frequency drives outside the pipe to control the speed. This paper briefly describes the overall MagPipe pipeline transportation system, including the preliminary conclusions of the linear synchronous motor analysis.

  6. Hydrodynamick instabilities on ICF capsules

    International Nuclear Information System (INIS)

    This article summarizes our current understanding of hydrodynamic instabilities as relevant to ICF. First we discuss classical, single mode Rayleigh-Taylor instability, and nonlinear effects in the evolution of a single mode. Then we discuss multimode systems, considering: (1) the onset of nonlinearity; (2) a second order mode coupling theory for weakly nonlinear effects, and (3) the fully nonlinear regime. Two stabilization mechanisms relevant to ICF are described next: gradient scale length and convective stabilization. Then we describe a model which is meant to estimate the weakly nonlinear evolution of multi-mode systems as relevant to ICF, given the short-wavelength stabilization. Finally, we discuss the relevant code simulation capability, and experiments. At this time we are quite optimistic about our ability to estimate instability growth on ICF capsules, but further experiments and simulations are needed to verify the modeling. 52 refs

  7. Instrumented Pipeline Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  8. Pipeline corridors through wetlands

    Energy Technology Data Exchange (ETDEWEB)

    Zimmerman, R.E.; Wilkey, P.L. (Argonne National Lab., IL (United States)); Isaacson, H.R. (Gas Research Institute (United States))

    1992-01-01

    This paper presents preliminary findings from six vegetational surveys of gas pipeline rights-of-way (ROW) through wetlands and quantifies the impacts of a 20-year-old pipeline ROW through a boreal forest wetland. Six sites of various ages were surveyed in ecosystems ranging from coastal marsh to forested wetland. At all sites except one, both the number and the percentage of wetland species on the Row approximated or exceeded those in the adjacent natural area. The boreal forest study showed that (1) adjacent natural wetland areas were not altered in type; (2) water sheet flow restriction had been reversed by nature; (3) no nonnative plant species invaded the natural area; (4) three-quarters of the ROW area was a wetland, and (5) the ROW increased diversity.

  9. Pipeline corridors through wetlands

    Energy Technology Data Exchange (ETDEWEB)

    Zimmerman, R.E.; Wilkey, P.L. [Argonne National Lab., IL (United States); Isaacson, H.R. [Gas Research Institute (United States)

    1992-12-01

    This paper presents preliminary findings from six vegetational surveys of gas pipeline rights-of-way (ROW) through wetlands and quantifies the impacts of a 20-year-old pipeline ROW through a boreal forest wetland. Six sites of various ages were surveyed in ecosystems ranging from coastal marsh to forested wetland. At all sites except one, both the number and the percentage of wetland species on the Row approximated or exceeded those in the adjacent natural area. The boreal forest study showed that (1) adjacent natural wetland areas were not altered in type; (2) water sheet flow restriction had been reversed by nature; (3) no nonnative plant species invaded the natural area; (4) three-quarters of the ROW area was a wetland, and (5) the ROW increased diversity.

  10. Constructing computational pipelines.

    Science.gov (United States)

    Halling-Brown, Mark; Shepherd, Adrian J

    2008-01-01

    Many bioinformatics tasks involve creating a computational pipeline from existing software components and algorithms. The traditional approach is to glue components together using scripts written in a programming language such as Perl. However, a new, more powerful approach is emerging that promises to revolutionise the way bioinformaticians create applications from existing components, an approach based on the concept of the scientific workflow. Scientific workflows are created in graphical environments known as workflow management systems. They have many benefits over traditional program scripts, including speed of development, portability, and their suitability for developing complex, distributed applications. This chapter explains how to design and implement bioinformatics workflows using free, Open Source software tools, such as the Taverna workflow management system. We also demonstrate how new and existing tools can be deployed as Web services so that they can be easily integrated into novel computational pipelines using the scientific workflow paradigm. PMID:18712319

  11. The inverse electroencephalography pipeline

    Science.gov (United States)

    Weinstein, David Michael

    The inverse electroencephalography (EEG) problem is defined as determining which regions of the brain are active based on remote measurements recorded with scalp EEG electrodes. An accurate solution to this problem would benefit both fundamental neuroscience research and clinical neuroscience applications. However, constructing accurate patient-specific inverse EEG solutions requires complex modeling, simulation, and visualization algorithms, and to date only a few systems have been developed that provide such capabilities. In this dissertation, a computational system for generating and investigating patient-specific inverse EEG solutions is introduced, and the requirements for each stage of this Inverse EEG Pipeline are defined and discussed. While the requirements of many of the stages are satisfied with existing algorithms, others have motivated research into novel modeling and simulation methods. The principal technical results of this work include novel surface-based volume modeling techniques, an efficient construction for the EEG lead field, and the Open Source release of the Inverse EEG Pipeline software for use by the bioelectric field research community. In this work, the Inverse EEG Pipeline is applied to three research problems in neurology: comparing focal and distributed source imaging algorithms; separating measurements into independent activation components for multifocal epilepsy; and localizing the cortical activity that produces the P300 effect in schizophrenia.

  12. ALMA Pipeline Heuristics

    Science.gov (United States)

    Lightfoot, J.; Wyrowski, F.; Muders, D.; Boone, F.; Davis, L.; Shepherd, D.; Wilson, C.

    2006-07-01

    The ALMA (Atacama Large Millimeter Array) Pipeline Heuristics system is being developed to automatically reduce data taken with the standard observing modes. The goal is to make ALMA user-friendly to astronomers who are not experts in radio interferometry. The Pipeline Heuristics system must capture the expert knowledge required to provide data products that can be used without further processing. Observing modes to be processed by the system include single field interferometry, mosaics and single dish `on-the-fly' maps, and combinations of these modes. The data will be produced by the main ALMA array, the ALMA Compact Array (ACA) and single dish antennas. The Pipeline Heuristics system is being developed as a set of Python scripts. For interferometry these use as data processing engines the CASA/AIPS++ libraries and their bindings as CORBA objects within the ALMA Common Software (ACS). Initial development has used VLA and Plateau de Bure data sets to build and test a heuristic script capable of reducing single field data. In this paper we describe the reduction datapath and the algorithms used at each stage. Test results are presented. The path for future development is outlined.

  13. Pipeline network and environment

    International Nuclear Information System (INIS)

    The Rio de Janeiro is one of 27 units of Brazil. It is located in the eastern portion of the Southeast and occupies an area of 43 696.054 km², being effectively the 3rd smallest state in Brazil. This state in recent years has suffered from erosion problems caused by the deployment of the network pipeline. The deployment pipeline is part of the activities related to the oil industry has caused a more intense conflict between the environment and economic activities, modifying the soil structure and distribution of surface and subsurface flows. This study aimed to analyze the erosion caused by the removal of soil for the deployment of pipeline transportation, with the consequences of the emergence of numerous gullies, landslides and silting of rivers. For the development of this study were performed bibliographic research, field work, mapping and digital preparation of the initial diagnosis of active processes and what the consequent environmental impacts. For these reasons, we conclude that the problems could be avoided or mitigated if there was a prior geological risk management. (author)

  14. Advances in material capsule technology in HANARO

    International Nuclear Information System (INIS)

    A material capsule system has been developed for irradiation tests of non-fissile materials in HANARO. This capsule system has been actively utilized for various material irradiation tests requested by users from research institutes, universities, and the industries. Based on the accumulated experience and the user's sophisticated requirements, several advances in material capsule technologies were obtained recently for a more precise control and analysis of the neutron irradiation effect in HANARO. New instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen, irrespective of the reactor operation, have been developed and out-pile tested. The OR/IP capsule technologies for an irradiation test in the HANARO OR and IP test holes with a relatively lower neutron flux than the CT and IR test holes have also been developed and in-pile tested, successfully. A high temperature irradiation technology up to 1000degC is under development. An evaluation of the DPA (Displacement Per Atom) and activation of irradiated specimens was attempted by using the SPECTOR and ORIGEN2 codes, respectively. A new fluence monitor with a decreased activity was designed to measure the thermal and fast neutron fluences of the irradiated specimens. A friction welded tube using STS304 and Al1050 alloys was introduced to prevent a coolant leakage into a capsule during a capsule cutting process after an irradiation. (author)

  15. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus. PMID:1307994

  16. [Karyosphere capsule in Tribolium castaneum oocytes].

    Science.gov (United States)

    Batalova, F M; Bogoliubov, D S

    2013-01-01

    Structure and composition of the karyosphere (karyosome) capsule were studied in the oocytes of a laboratory insect, Tribolium castaneum, with the use of electron microscopy and immunoelectron cytochemistry. Basing on the study of nuclear structure dynamics, we distinguished 8 stages that characterize the period of oocyte growth. At the diplotene stage, T. castaneum oocyte chromosomes conjoin early into a compact karyosphere, but a significant chromatin condensation does not occur. The process of karyosphere formation is accompanied by the development of an extensive extrachromosome capsule surrounding chromatin. The capsule consists of a material of different morphological types. Significant molecular components of the T. castaneum karyosphere capsule are represented by the proteins of nuclear matrix including F-actin and lamin B. Besides the structural proteins, the Sm proteins of small nuclear (sn) RNPs and mature 2,2,7-trimethyl guanosine (TMG) 5'-capped snRNAs are revealed immunocytochemically in the karyosphere capsule. The obtained data can form a basis for further expansion of ideas on the functions of the karyosphere capsule as a specialized extrachromosomal nuclear domain of the oocytes. We believe that the T. castaneum karyosphere capsule plays not only a structural role, but may be involved directly in the processes related to gene expression.

  17. Asymmetric membrane osmotic capsules for terbutaline sulphate

    Directory of Open Access Journals (Sweden)

    N G Gobade

    2012-01-01

    Full Text Available The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate.

  18. Asymmetric membrane osmotic capsules for terbutaline sulphate.

    Science.gov (United States)

    Gobade, N G; Koland, Marina; Harish, K H

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate. PMID:23204625

  19. North Slope pipeline work strong; gas pipeline project deferred

    Energy Technology Data Exchange (ETDEWEB)

    Hale, D.

    1982-09-01

    Over 225 miles of insulated pipelines will be installed on the North Slope as part of a 5-year, $10.5 billion program by Sohio and Arco to maintain output from the field to feed the trans-Alaska oil pipeline. New lines are for waterflood supply systems, low pressure production systems, produced water handling, and gas handling. Pipeline construction is quite active at both Prudhoe Bay and at Kuparuk Field. Future projects include an oil line to the Beaufort Sea, the Polar Gas Project, the Arctic Pilot project, and the Northern Tier Pipeline.

  20. Product through pipelines : transportation options

    Energy Technology Data Exchange (ETDEWEB)

    Ballyntyne, R. [Terasen Pipelines, Calgary, AB (Canada)

    2004-07-01

    This PowerPoint presentation provided a brief overview of the corporate structure of Terasen Pipelines along with a map displaying the locations of the pipelines it operates and new directions for growth. It also presented a proposal to deliver petroleum products from Alberta's oilsand fields to markets via the Corridor and Express pipeline systems, and evaluated the issue of transporting petrochemicals via rail transport rather than pipeline. Industry is also examining the option of shipping refined products through a trans mountain system from Alberta to British Columbia and California. A chart highlighting Canadian crude oil production was presented along with an oil sands pipeline capacity chart. It was noted that significant investment in refining capacity is needed and that new pipeline facilities will be required to meet the needs of oil sands developments. tabs., figs.

  1. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the...

  2. Capsule Retentions and Incomplete Capsule Endoscopy Examinations: An Analysis of 2300 Examinations

    OpenAIRE

    Charlotte M. Höög; Lars-Åke Bark; Juan Arkani; Jacob Gorsetman; Olle Broström; Urban Sjöqvist

    2011-01-01

    Aim. To evaluate capsule endoscopy in terms of incomplete examinations and capsule retentions and to find risk factors for these events. Material and Methods. This retrospective and consecutive study includes data from 2300 capsule enteroscopy examinations, performed at four different hospitals in Stockholm, Sweden from 2003 to 2009. Results. The frequency of incomplete examinations was 20%. Older age, male gender, suspected, and known Crohn's disease were risk factors for an incomplete exami...

  3. Slurry pipeline technology: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Jay P. [Pipeline Systems Incorporated (PSI), Belo Horizonte, MG (Brazil); Lima, Rafael; Pinto, Daniel; Vidal, Alisson [Ausenco do Brasil Engenharia Ltda., Nova Lima, MG (Brazil). PSI Div.

    2009-12-19

    Slurry pipelines represent an economical and environmentally friendly transportation means for many solid materials. This paper provides an over-view of the technology, its evolution and current Brazilian activity. Mineral resources are increasingly moving farther away from ports, processing plants and end use points, and slurry pipelines are an important mode of solids transport. Application guidelines are discussed. State-of-the-Art technical solutions such as pipeline system simulation, pipe materials, pumps, valves, automation, telecommunications, and construction techniques that have made the technology successful are presented. A discussion of where long distant slurry pipelines fit in a picture that also includes thickened and paste materials pipe lining is included. (author)

  4. Therapeutic Capsule Endoscopy: Opportunities and Challenges

    Directory of Open Access Journals (Sweden)

    Mahdi Rasouli

    2011-01-01

    Full Text Available The increasing demand for non-invasive (or less-invasive monitoring and treatment of medical conditions has attracted both physicians and engineers to work together and investigate new methodologies. Wireless capsule endoscopy is a successful example of such techniques which has become an accepted routine for diagnostic inspection of the gastrointestinal tract. This method offers a non-invasive alternative to traditional endoscopy and provides the opportunity for exploring distal areas of the small intestine which are otherwise not accessible. Despite these advantages, wireless capsule endoscopy is still limited in functionality compared to traditional endoscopy. Wireless capsule endoscopes with advanced functionalities, such as biopsy or drug delivery, are highly desirable. In this article, the current status of wireless capsule endoscopy is reviewed together with some of its possible therapeutic applications as well as the existing challenges.

  5. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Bill Bruce; Nancy Porter; George Ritter; Matt Boring; Mark Lozev; Ian Harris; Bill Mohr; Dennis Harwig; Robin Gordon; Chris Neary; Mike Sullivan

    2005-07-20

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  6. Capsule endoscopy in patients refusing conventional endoscopy

    OpenAIRE

    Romero-Vázquez, Javier; Argüelles-Arias, Federico; García-Montes, Josefa Maria; Caunedo-Álvarez, Ángel; Pellicer-Bautista, Francisco Javier; Herrerías-Gutiérrez, Juan Manuel

    2014-01-01

    Capsule endoscopy is nowadays the diagnostic technique of choice in the study of small bowel pathologies, allowing the non-invasive study of the entire mucosa. This has led, together with new technical advances, to the creation of two new models (PillCam ESO and PillCam Colon) for the study of esophageal and colonic diseases. These two new capsules offer an interesting alternative to conventional endoscopy in the study of the upper and lower digestive tracts, because traditional endoscopy is ...

  7. 76 FR 70953 - Pipeline Safety: Safety of Gas Transmission Pipelines

    Science.gov (United States)

    2011-11-16

    ... August 25, 2011, (76 FR 53086) PHMSA published in the Federal Register an Advance Notice of Proposed... by email at mike.israni@dot.gov . SUPPLEMENTARY INFORMATION: On August 25, 2011, (76 FR 53086), PHMSA... Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 RIN 2137-AE72 Pipeline...

  8. Towards Polymer-Based Capsules with Drastically Reduced Controlled Permeability

    Science.gov (United States)

    Andreeva, Daria V.; Sukhorukov, Gleb B.

    Small molecules (dyes, therapeutics, etc.) could be easily handled, stored, delivered, and released by polyelectrolyte capsules. To make the polyelectrolyte capsule more efficient for small molecule encapsulation, capsule permeability should be significantly decreased. Here, we demonstrate the possibility to entrap water-soluble molecular species into polyelectrolyte capsules modified by a low permeable dense polymer (polypyrrole). Possible future areas in PE capsule application as carriers for gases and volatiles in the pharmaceutical, food, and gases industry, agriculture and cosmetology are discussed.

  9. The LOFAR Transients Pipeline

    Science.gov (United States)

    Swinbank, John D.; Staley, Tim D.; Molenaar, Gijs J.; Rol, Evert; Rowlinson, Antonia; Scheers, Bart; Spreeuw, Hanno; Bell, Martin E.; Broderick, Jess W.; Carbone, Dario; Garsden, Hugh; van der Horst, Alexander J.; Law, Casey J.; Wise, Michael; Breton, Rene P.; Cendes, Yvette; Corbel, Stéphane; Eislöffel, Jochen; Falcke, Heino; Fender, Rob; Grießmeier, Jean-Mathias; Hessels, Jason W. T.; Stappers, Benjamin W.; Stewart, Adam J.; Wijers, Ralph A. M. J.; Wijnands, Rudy; Zarka, Philippe

    2015-06-01

    Current and future astronomical survey facilities provide a remarkably rich opportunity for transient astronomy, combining unprecedented fields of view with high sensitivity and the ability to access previously unexplored wavelength regimes. This is particularly true of LOFAR, a recently-commissioned, low-frequency radio interferometer, based in the Netherlands and with stations across Europe. The identification of and response to transients is one of LOFAR's key science goals. However, the large data volumes which LOFAR produces, combined with the scientific requirement for rapid response, make automation essential. To support this, we have developed the LOFAR Transients Pipeline, or TraP. The TraP ingests multi-frequency image data from LOFAR or other instruments and searches it for transients and variables, providing automatic alerts of significant detections and populating a lightcurve database for further analysis by astronomers. Here, we discuss the scientific goals of the TraP and how it has been designed to meet them. We describe its implementation, including both the algorithms adopted to maximize performance as well as the development methodology used to ensure it is robust and reliable, particularly in the presence of artefacts typical of radio astronomy imaging. Finally, we report on a series of tests of the pipeline carried out using simulated LOFAR observations with a known population of transients.

  10. Mudslide effects on offshore pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Swanson, R.C.; Jones, W.T.

    1982-11-01

    In regions of unstable soils such as portions of the Mississippi Delta, occasional pipeline failures during periods of severe weather have been attributed to mudslides. The effects of such downslope soil movements on the deflection and resulting stress in a pipeline have been studied in an attempt to reveal methods of routing or design which would reduce the risk of failure. Results show that the chances of surviving a slide are increased if the pipeline outer diameter is reduced to as small a value as possible, if the pipe wall thickness is increased, and if some slack is available in the line. The chance of survival is greatest if the slide occurs in a direction perpendicular to the pipeline route since the failure mode is primarily one of tension. When the slide crosses the pipeline at other angles of incidence, the chance of survival is significantly lessened.

  11. 75 FR 67807 - Pipeline Safety: Emergency Preparedness Communications

    Science.gov (United States)

    2010-11-03

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Emergency Preparedness Communications AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice... and hazardous liquid pipeline facilities that they must make their pipeline emergency response...

  12. Capsule endoscopy in neoplastic diseases

    Institute of Scientific and Technical Information of China (English)

    Marco Pennazio; Emanuele Rondonotti; Roberto de Franchis

    2008-01-01

    Until recently,diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques.An array of new methods has recently been developed,increasing the possibility of detecting these tumors at an earlier stage.Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ,since it is non-invasive and enables the entire small bowel to be visualized.Highquality images of the small-bowel mucosa may be captured and small and fiat lesions recognized,without exposure to radiation.Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range,1.6%-2.4%)and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding.The majority of tumors identified by CE are malignant;many were unsuspected and not found by other methods.However,it remains difficult to identify pathology and tumor type based on the lesion's endoscopic appearance.Despite its limitations,CE provides crucial information leading in most cases to changes in subsequent patient management.Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms,ultimately resulting in a survival advantage and in cost savings,remains to be determined through carefully-designed studies.

  13. 3D Printed Programmable Release Capsules.

    Science.gov (United States)

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients. PMID:26042472

  14. Lubricin in human breast tissue expander capsules.

    Science.gov (United States)

    Cheriyan, Thomas; Guo, Lifei; Orgill, Dennis P; Padera, Robert F; Schmid, Thomas M; Spector, Myron

    2012-10-01

    Capsular contraction is the most common complication of breast reconstruction surgery. While presence of the contractile protein alpha smooth muscle actin (α-SMA) is considered among the causes of capsular contraction, the exact etiology and pathophysiology is not fully understood. The objective of this study was to investigate the possible role of lubricin in capsular formation and contraction by determining the presence and distribution of the lubricating protein lubricin in human breast tissue expander capsules. Related aims were to evaluate select histopathologic features of the capsules, and the percentage of cells expressing α-SMA, which reflects the myofibroblast phenotype. Capsules from tissue expanders were obtained from eight patients. Lubricin, at the tissue-implant interface, in the extracellular matrix, and in cells, and α-SMA-containing cells were evaluated immunohistochemically. The notable finding was that lubricin was identified in all tissue expander capsules: as a discrete layer at the tissue-implant interface, extracellular, and intracellular. There was a greater amount of lubricin in the extracellular matrix in the intimal-subintimal zone when compared with the tissue away from the implant. Varying degrees of synovial metaplasia were seen at the tissue-implant interface. α-SMA-containing cells were also seen in all but one patient. The findings might help us better understand factors involved in capsule formation.

  15. Maglev crude oil pipeline

    Science.gov (United States)

    Knolle, Ernst G.

    1994-05-01

    This maglev crude oil pipeline consists of two conduits guiding an endless stream of long containers. One conduit carries loaded containers and the other empty returns. The containers are levitated by permanent magnets in repulsion and propelled by stationary linear induction motors. The containers are linked to each other in a manner that allows them, while in continuous motion, to be folded into side by side position at loading and unloading points. This folding causes a speed reduction in proportion to the ratio of container diameter to container length. While in side by side position, containers are opened at their ends to be filled or emptied. Container size and speed are elected to produce a desired carrying capacity.

  16. Shipping Information Pipeline

    DEFF Research Database (Denmark)

    Jensen, Thomas; Vatrapu, Ravi

    2015-01-01

    This paper presents a design science approach to solving persistent problems in the international shipping eco system by creating the missing common information infrastructures. Specifically, this paper reports on an ongoing dialogue between stakeholders in the shipping industry and information...... systems researchers engaged in the design and development of a prototype for an innovative IT-artifact called Shipping Information Pipeline which is a kind of “an internet” for shipping information. The instrumental aim is to enable information seamlessly to cross the organizational boundaries...... and national borders within international shipping which is a rather complex domain. The intellectual objective is to generate and evaluate the efficacy and effectiveness of design principles for inter-organizational information infrastructures in the international shipping domain that can have positive...

  17. Maglev crude oil pipeline

    Science.gov (United States)

    Knolle, Ernst G.

    1994-01-01

    This maglev crude oil pipeline consists of two conduits guiding an endless stream of long containers. One conduit carries loaded containers and the other empty returns. The containers are levitated by permanent magnets in repulsion and propelled by stationary linear induction motors. The containers are linked to each other in a manner that allows them, while in continuous motion, to be folded into side by side position at loading and unloading points. This folding causes a speed reduction in proportion to the ratio of container diameter to container length. While in side by side position, containers are opened at their ends to be filled or emptied. Container size and speed are elected to produce a desired carrying capacity.

  18. Pipeline risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kariyawasam, S. [TransCanada PipeLines Ltd., Calgary, AB (Canada); Weir, D. [Enbridge Pipelines Inc., Calgary, AB (Canada)] (comps.)

    2009-07-01

    Risk assessments and risk analysis are system-wide activities that include site-specific risk and reliability-based decision-making, implementation, and monitoring. This working group discussed the risk management process in the pipeline industry, including reliability-based integrity management and risk control processes. Attendants at the group discussed reliability-based decision support and performance measurements designed to support corporate risk management policies. New developments and technologies designed to optimize risk management procedures were also presented. The group was divided into 3 sessions: (1) current practice, strengths and limitations of system-wide risk assessments for facility assets; (2) accounting for uncertainties to assure safety; and (3) reliability based excavation repair criteria and removing potentially unsafe corrosion defects. Presentations of risk assessment procedures used at various companies were given. The role of regulators, best practices, and effective networking environments in ensuring the success of risk assessment policies was discussed. Risk assessment models were also reviewed.

  19. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-08-17

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners

  20. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-12-31

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  1. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; Nancy Porter; Mike Sullivan; Chris Neary

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforced composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created

  2. Northern pipelines : challenges and needs

    Energy Technology Data Exchange (ETDEWEB)

    Dean, D.; Brownie, D. [ProLog Canada Inc., Calgary, AB (Canada); Fafara, R. [TransCanada PipeLines Ltd., Calgary, AB (Canada)

    2007-07-01

    Working Group 10 presented experiences acquired from the operation of pipeline systems in a northern environment. There are currently 3 pipelines operating north of 60, notably the Shiha gas pipeline near Fort Liard, the Ikhil gas pipeline in Inuvik and the Norman Wells oil pipeline. Each has its unique commissioning, operating and maintenance challenges, as well as specific training and logistical support requirements for the use of in-line inspection tools and other forms of integrity assessment. The effectiveness of cathodic protection systems in a permafrost northern environment was also discussed. It was noted that the delay of the Mackenzie Gas Pipeline Project by two to three years due to joint regulatory review may lead to resource constraints for the project as well as competition for already scarce human resources. The issue of a potential timing conflict with the Alaskan Pipeline Project was also addressed as well as land use issues for routing of supply roads. Integrity monitoring and assessment issues were outlined with reference to pipe soil interaction monitoring in discontinuous permafrost; south facing denuded slope stability; base lining projects; and reclamation issues. It was noted that automatic welding and inspection will increase productivity, while reducing the need for manual labour. In response to anticipated training needs, companies are planning to involve and train Aboriginal labour and will provide camp living conditions that will attract labour. tabs., figs.

  3. Pipeline clean-up : speed, environment drive pipelining equipment

    Energy Technology Data Exchange (ETDEWEB)

    Budd, G.

    2004-08-01

    Horizontal drilling technology is the single most important enhanced oil recovery technology which has resulted in a significant increase in pipeline utilization. Pipeline operators such as Calgary-based Denim Pipeline Construction Ltd. are responding by using the latest equipment, including excavation equipment, to avoid maintenance delays and downtime. The sales of Denim's horizontal pipe bending equipment have increased due to their attention to worker safety. Denim's horizontal bending machine does not require as much technical support, plus it is faster to install and speeds up production. The machine consists of 3 hydraulic jacks that move on a horizontal plate. Curved dies can be modified to accommodate various diameters of pipe. The bending operation is performed very near to the ground, thereby significantly reducing the risk of pipe injury. Environmental damage is minimized through the use of mechanized mulching which has replaced burning of unwanted trees and brush to clean for pipelines. 1 fig.

  4. Effort problem of chemical pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Okrajni, J.; Ciesla, M.; Mutwil, K. [Silesian Technical University, Katowice (Poland)

    1998-12-31

    The problem of the technical state assessment of the chemical pipelines working under mechanical and thermal loading has been shown in the paper. The pipelines effort after the long time operating period has been analysed. Material geometrical and loading conditions of the crack initiation and crack growth process in the chosen object has been discussed. Areas of the maximal effort have been determined. The material structure charges after the long time operating period have been described. Mechanisms of the crack initiation and crack growth in the pipeline elements have been analysed and mutual relations between the chemical and mechanical influences have been shown. (orig.) 16 refs.

  5. RUSSIA AND ITS PIPELINE WEAPON

    Directory of Open Access Journals (Sweden)

    FODOR Cosmin

    2010-12-01

    Full Text Available In this paper we intend to present the new power which is given to Russia upon EU due to her great natural resources and due to her control upon pipelines. Now Moscow can exert influence upon countries in Europe not through its revolutionary zeal and its tanks and army, but through its resources. And she knows how to use them and how make the EU dependent on her will: this is a new geopolitics, a 21-th century geopolitics, which is centered upon the control of gas pipelines in Central Asian states and upon EU states great dependence on Russian pipeline system.

  6. Natural gas pipeline technology overview.

    Energy Technology Data Exchange (ETDEWEB)

    Folga, S. M.; Decision and Information Sciences

    2007-11-01

    The United States relies on natural gas for one-quarter of its energy needs. In 2001 alone, the nation consumed 21.5 trillion cubic feet of natural gas. A large portion of natural gas pipeline capacity within the United States is directed from major production areas in Texas and Louisiana, Wyoming, and other states to markets in the western, eastern, and midwestern regions of the country. In the past 10 years, increasing levels of gas from Canada have also been brought into these markets (EIA 2007). The United States has several major natural gas production basins and an extensive natural gas pipeline network, with almost 95% of U.S. natural gas imports coming from Canada. At present, the gas pipeline infrastructure is more developed between Canada and the United States than between Mexico and the United States. Gas flows from Canada to the United States through several major pipelines feeding U.S. markets in the Midwest, Northeast, Pacific Northwest, and California. Some key examples are the Alliance Pipeline, the Northern Border Pipeline, the Maritimes & Northeast Pipeline, the TransCanada Pipeline System, and Westcoast Energy pipelines. Major connections join Texas and northeastern Mexico, with additional connections to Arizona and between California and Baja California, Mexico (INGAA 2007). Of the natural gas consumed in the United States, 85% is produced domestically. Figure 1.1-1 shows the complex North American natural gas network. The pipeline transmission system--the 'interstate highway' for natural gas--consists of 180,000 miles of high-strength steel pipe varying in diameter, normally between 30 and 36 inches in diameter. The primary function of the transmission pipeline company is to move huge amounts of natural gas thousands of miles from producing regions to local natural gas utility delivery points. These delivery points, called 'city gate stations', are usually owned by distribution companies, although some are owned by

  7. 77 FR 16471 - Pipeline Safety: Implementation of the National Registry of Pipeline and Liquefied Natural Gas...

    Science.gov (United States)

    2012-03-21

    ...: Implementation of the National Registry of Pipeline and Liquefied Natural Gas Operators AGENCY: Pipeline and... registry of pipeline and liquefied natural gas operators. This notice provides updates to the information... the Federal Register (75 FR 72878) titled: ``Pipeline Safety: Updates to Pipeline and...

  8. 77 FR 5472 - Pipeline Safety: Miscellaneous Changes to Pipeline Safety Regulations

    Science.gov (United States)

    2012-02-03

    ... amendments to the pipeline safety regulations (76 FR 73570). On January 12, 2012, the Interstate Natural Gas... Pipeline and Hazardous Materials Safety Administration 49 CFR Parts 191, 192 and 195 RIN 2137-AE59 Pipeline Safety: Miscellaneous Changes to Pipeline Safety Regulations AGENCY: Pipeline and Hazardous...

  9. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  10. Intestinal preparation prior to capsule endoscopy administration

    Institute of Scientific and Technical Information of China (English)

    Vicente Pons Beltrán; Cristina Carretero; Bego(n)a Gonzalez-Suárez; I(n)aqui Fernández-Urien; Miguel Mu(n)oz Navas

    2008-01-01

    In order to have an adequate view of the whole small intestine during capsule endoscopy,the preparation recommended consists of a clear liquid diet and an overnight fast.However,visualization of the small bowel during video capsule endoscopy can be impaired by intestinal contents.To improve mucosal visualization,some authors have evaluated different regimens of preparation.There is no consensus about the necessity of intestinal preparation for capsule endoscopy and it should be interesting to develop adequate guidelines to improve its efficacy and tolerability.Moreover,the effect of preparation type (purgative) on intestinal transit time is not clear.Since a bowel preparation cannot definitively improve its visibility (and theoretically the yield of the test),it is not routinely recommended.

  11. Pipeline integrity handbook risk management and evaluation

    CERN Document Server

    Singh, Ramesh

    2013-01-01

    Based on over 40 years of experience in the field, Ramesh Singh goes beyond corrosion control, providing techniques for addressing present and future integrity issues. Pipeline Integrity Handbook provides pipeline engineers with the tools to evaluate and inspect pipelines, safeguard the life cycle of their pipeline asset and ensure that they are optimizing delivery and capability. Presented in easy-to-use, step-by-step order, Pipeline Integrity Handbook is a quick reference for day-to-day use in identifying key pipeline degradation mechanisms and threats to pipeline integrity. The book begins

  12. Logistics aspects of petroleum pipeline operations

    Directory of Open Access Journals (Sweden)

    W. J. Pienaar

    2010-11-01

    Full Text Available The paper identifies, assesses and describes the logistics aspects of the commercial operation of petroleum pipelines. The nature of petroleum-product supply chains, in which pipelines play a role, is outlined and the types of petroleum pipeline systems are described. An outline is presented of the nature of the logistics activities of petroleum pipeline operations. The reasons for the cost efficiency of petroleum pipeline operations are given. The relative modal service effectiveness of petroleum pipeline transport, based on the most pertinent service performance measures, is offered. The segments in the petroleum-products supply chain where pipelines can play an efficient and effective role are identified.

  13. Video capsule endoscopy in inflammatory bowel disease

    Science.gov (United States)

    Collins, Paul D

    2016-01-01

    Video capsule endoscopy (VCE) has evolved to become an important tool for the non-invasive examination of the small bowel, which hitherto had been relatively inaccessible to direct visualisation. VCE has been shown to play a role in monitoring the activity of small bowel Crohn’s disease and can be used to assess the response to anti-inflammatory treatment in Crohn’s disease. For those patients with Crohn’s disease who have undergone an intestinal resection, VCE has been assessed as a tool to detect post-operative recurrence. VCE may also aid in the reclassification of patients with a diagnosis of Inflammatory Bowel Disease Unclassified to Crohn’s disease. The evolution of colon capsule endoscopy (CCE) has expanded the application of this technology further. The use of CCE to assess the activity of ulcerative colitis has been described. This advance in capsule technology has also fuelled interest in its potential role as a minimally invasive tool to assess the whole of GI tract opening the possibility of its use for the panenteric assessment of Crohn’s disease. VCE is a safe procedure. However, the risk of a retained capsule is higher in patients with suspected or confirmed Crohn’s disease compared with patients having VCE examination for other indications. A retained video capsule is rare after successful passage of a patency capsule which may be utilised to pre-screen patients undergoing VCE. This paper describes the use of VCE in the assessment of inflammatory bowel disease. PMID:27499830

  14. Capsules with external navigation and triggered release.

    Science.gov (United States)

    Shchukin, Dmitry G; Shchukina, Elena

    2014-10-01

    Encapsulation is an important technology for pharmaceutical industry, food production, et cetera. Its current level of development requires capsule functionalization. One of the interesting ideas to provide new functionality to the microcapsule and nanocapsule is layer-by-layer deposition of functional species. This technique provides step-by-step adsorption of various species (polyelectrolytes, nanoparticles, proteins) when the layer growth is controlled by electrostatic, hydrogen bonding, hydrophobic forces and forming multilayer shells with nanometer precision. This review article introduces recent achievements of layer-by-layer technique attaining external navigation ability and release properties the capsule shell.

  15. Study on Detection Technique for Pipeline Leakage

    Institute of Scientific and Technical Information of China (English)

    李健; 王立坤; 周琰; 靳世久

    2003-01-01

    Pipeline integrity defect is a considerable portion in all the defects. Therefore, the study on detection technique is of great concern to the owners of pipelines. A real-time monitoring system of pipeline defect is established. For unexpected accidents of pipeline leakage, several methods of signal processing, including wavelet analysis are utilized. The leakage can be located accurately in time. This system is applied to many long distance pipelines in China, which has made great contributions to the economy.

  16. Logistics aspects of petroleum pipeline operations

    OpenAIRE

    W. J. Pienaar

    2010-01-01

    The paper identifies, assesses and describes the logistics aspects of the commercial operation of petroleum pipelines. The nature of petroleum-product supply chains, in which pipelines play a role, is outlined and the types of petroleum pipeline systems are described. An outline is presented of the nature of the logistics activities of petroleum pipeline operations. The reasons for the cost efficiency of petroleum pipeline operations are given. The relative modal service effectiveness of petr...

  17. Nondestructive characterization of pipeline materials

    Science.gov (United States)

    Engle, Brady J.; Smart, Lucinda J.; Bond, Leonard J.

    2015-03-01

    There is a growing need to quantitatively and nondestructively evaluate the strength and toughness properties of pipeline steels, particularly in aging pipeline infrastructure. These strength and toughness properties, namely yield strength, tensile strength, transition temperature, and toughness, are essential for determining the safe operating pressure of the pipelines. For some older pipelines crucial information can be unknown, which makes determining the pressure rating difficult. Current inspection techniques address some of these issues, but they are not comprehensive. This paper will briefly discuss current inspection techniques and relevant literature for relating nondestructive measurements to key strength and toughness properties. A project is in progress to provide new in-trench tools that will give strength properties without the need for sample removal and destructive testing. Preliminary experimental ultrasonic methods and measurements will be presented, including velocity, attenuation, and backscatter measurements.

  18. Pipelines programming paradigms: Prefab plumbing

    International Nuclear Information System (INIS)

    Mastery of CMS Pipelines is a process of learning increasingly sophisticated tools and techniques that can be applied to your problem. This paper presents a compilation of techniques that can be used as a reference for solving similar problems

  19. Pipeline Processing of VLBI Data

    CERN Document Server

    Reynolds, C; Garrett, M

    2002-01-01

    As part of an on-going effort to simplify the data analysis path for VLBI experiments, a pipeline procedure has been developed at JIVE to carry out much of the data reduction required for EVN experiments in an automated fashion. This pipeline procedure runs entirely within AIPS, the standard data reduction package used in astronomical VLBI, and is used to provide preliminary calibration of EVN experiments correlated at the EVN MkIV data processor. As well as simplifying the analysis for EVN users, the pipeline reduces the delay in providing information on the data quality to participating telescopes, hence improving the overall performance of the array. A description of this pipeline is presented here.

  20. PIPELINES AS COMMUNICATION NETWORK LINKS

    Energy Technology Data Exchange (ETDEWEB)

    Kelvin T. Erickson; Ann Miller; E. Keith Stanek; C.H. Wu; Shari Dunn-Norman

    2005-03-14

    This report presents the results of an investigation into two methods of using the natural gas pipeline as a communication medium. The work addressed the need to develop secure system monitoring and control techniques between the field and control centers and to robotic devices in the pipeline. In the first method, the pipeline was treated as a microwave waveguide. In the second method, the pipe was treated as a leaky feeder or a multi-ground neutral and the signal was directly injected onto the metal pipe. These methods were tested on existing pipeline loops at UMR and Batelle. The results reported in this report indicate the feasibility of both methods. In addition, a few suitable communication link protocols for this network were analyzed.

  1. Capsule endoscopy: Current status in obscure gastrointestinal bleeding

    Institute of Scientific and Technical Information of China (English)

    R Gupta; Nageshwar Duvvuru Reddy

    2007-01-01

    Capsule endoscopy (CE) is a safe, non invasive diagnostic modality for the evaluation of small bowel lesions. Obscure gastrointestinal bleeding (OGIB) is one of the most important indications of capsule endoscopy.Capsule endoscopy has a very high diagnostic yield especially if the bleeding is ongoing. This technique appears to be superior to other techniques for the detection of suspected lesions and the source of bleeding. Capsule endoscopy has been shown to change the outcome in patients with obscure gastrointestinal (GI)bleed.

  2. ADHESIVE CAPSULITIS: USE THE EVIDENCE TO INTEGRATE YOUR INTERVENTIONS

    OpenAIRE

    Page, Phil; Labbe, Andre

    2010-01-01

    Frozen shoulder syndrome, clinically known as adhesive capsulitis, is a painful and debilitating condition affecting up to 5% of the population. Adhesive capsulitis is considered fibrosis of the glenohumeral joint capsule with a chronic inflammatory response. Patients experience pain, limited range of motion, and disability generally lasting anywhere from 1 to 24 months. The purpose of this clinical suggestion is to review the pathophysiolgy of adhesive capsulitis and discuss physical therapy...

  3. The LOFAR Pulsar Data Pipeline

    Science.gov (United States)

    Alexov, A.; Hessels, J.; Mol, J. D.; Stappers, B.; van Leeuwen, J.

    2010-12-01

    The LOw Frequency ARray (LOFAR) for radio astronomy is being built in the Netherlands by ASTRON, with extensions throughout Europe. LOFAR operates at radio frequencies below 250 MHz. The project is an interferometric array of radio antennas grouped into stations that are distributed over an area of hundreds of kilometers. LOFAR will revolutionise low-frequency radio astronomy. Transient radio phenomena and pulsars are one of six LOFAR Key Science Projects (KSPs). As part of the Transients KSP, the Pulsar Working Group has been developing the LOFAR Pulsar Data Pipeline to both study known pulsars as well as search for new ones. The pipeline is being developed for the Blue Gene/P (BG/P) supercomputer and a large Linux cluster in order to utilize enormous amounts of computation capabilities (˜ 50 Tflops) and data streams of up to 23TB/hour. The LOFAR pipeline output will be using the Hierarchical Data Format 5 (HDF5) to efficiently store large amounts of numerical data, and to manage complex data encompassing a variety of data types, across distributed storage and processing architectures. We present the LOFAR Pulsar Data Pipeline overview, the pulsar beam-formed data format, the status of the pipeline processing as well as our future plans for developing additional transient pipelines.

  4. Solving an unpiggable pipeline challenge

    Energy Technology Data Exchange (ETDEWEB)

    Walker, James R. [GE Oil and Gas, PII Pipeline Solutions, Cramlington Northumberland (United Kingdom); Kern, Michael [National Grid, New Hampshire (United Kingdom)

    2009-07-01

    Technically, any pipeline can be retrofitted to enable in line inspection. Sensibly however, the expense of excavations and construction of permanent facilities have been, in many cases, exceedingly prohibitive. Even where traditional modifications are feasible from engineering perspectives, flow interruption may not be an option - either because they are critical supply lines or because the associated lost revenues could be nearly insurmountable. Savvy pipeline integrity managers know the safety issue that is at stake over the long term. They are also well aware of the accuracy benefits that high-quality in-line inspection data offer over potentially supply disruptive alternatives such as hydrostatic testing. To complicate matters further, many operators, particularly in the US, now face regulatory pressure to assess the integrity of their yet-uninspected pipelines located in highly populated areas. This paper describes an important project National Grid undertook that made use of a unique pipeline access method that did not require permanent installation of expensive facilities required for in line inspection of a pipeline previously considered 'unpiggable'. Since the pipeline was located in an urban area, flow disruption had to be minimized. This paper will define the project background, its challenges, outcomes and lessons learned for the future. (author)

  5. Pipeline integrity through cathodic protection

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, N. [Gas Authority India Ltd., New Delhi (India); Khanna, A.S. [Indian Inst. of Technology, Bombay (India)

    2008-07-01

    Pipeline integrity management is defined as a process for assessing and mitigating pipeline risks in an effort to reduce both the likelihood and consequences of incidents. Defects on pipelines result in production losses, environmental losses, as well as loss of goodwill and subsequent financial losses. This presentation addressed pipeline integrity through cathodic protection. It noted that pipeline integrity can be strengthened by successfully controlling, monitoring and mitigating corrosion strategies. It can also be achieved by avoiding external and internal corrosion failures. A good coating offers the advantages of low current density; lower power consumption; low wear of anodes; larger spacing between cathodic protection stations; and minimization of interference problems. The presentation reviewed cathodic protection of cross-country pipelines; a sacrificial cathodic protection system; and an impressed current cathodic protection system. The efficiency of a cathodic system was shown to depend on the use of reliable power sources; proper protection criterion; efficient and effective monitoring of cathodic protection; proper maintenance of the cathodic protection system; and effective remedial measures. Selection criteria, power sources, and a comparison of cathodic protection sources were also presented. Last, the presentation addressed protection criteria; current interruption circuits; monitoring of the cathodic protection system; use of corrosion coupons; advantages of weightless coupons; checking the insulating flanges for shorted bolts; insulated/short casings; anodic and cathodic interference; common corridor problems; and intelligent pigging. tabs., figs.

  6. 21 CFR 520.2345a - Tetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Tetracycline hydrochloride capsules. 520.2345a... Tetracycline hydrochloride capsules. (a) Specifications. Each capsule contains 50, 100, 125, 250, or 500 milligrams (mg) tetracycline hydrochloride. (b) Sponsor. See sponsors in § 510.600(c) of this chapter for...

  7. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium monohydrate equivalent to 50, 100, 200, or 500 milligrams of dicloxacillin. (b) Sponsor. See No. 000856...

  8. 21 CFR 872.3110 - Dental amalgam capsule.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with...

  9. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW. PMID:25376042

  10. Student Mobility. Information Capsule. Volume 0608

    Science.gov (United States)

    Blazer, Christie

    2007-01-01

    Mobility, rather than stability, has become the norm for students in schools across the United States. The student mobility rate is now higher in the United States than in any other industrialized country. This Information Capsule discusses the reasons for student mobility and the characteristics of highly mobile students and families. Research…

  11. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K;

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human ch...

  12. Symptomatic Patency Capsule Retention in Suspected Crohn's Disease

    DEFF Research Database (Denmark)

    Rasmussen, Bjørn; Nathan, Torben; Jensen, Michael Dam

    2016-01-01

    The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two...... patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography...

  13. China Oil & Gas Pipeline Survey & Design Institute, Pipeline

    Institute of Scientific and Technical Information of China (English)

    Bureau of CNPC; Zhao Surong

    1995-01-01

    @@ China Oil/Gas Pipeline Bureau(P.B) is the only professional organization in China specialized in oil/gas pipelines design and construction since 1980s. It has ever cooperated with certain number of well known companies from Japan,USA, Germany, Canada, as well as Italy in the designs of many large oil/gas pipeline projects, during the course of which, personnel from P.B accumulated much experience in international project designs. During the execution of each particular project, they strictly followed the common-use international codes and standards with computers as the auxiliary design system combined with the self-developed software. All its clients showed their trust in this organization and gave it high praise for its outstanding survey, design and technical service.

  14. 77 FR 61826 - Pipeline Safety: Communication During Emergency Situations

    Science.gov (United States)

    2012-10-11

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Communication During Emergency Situations AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice..., hazardous liquid, and liquefied natural gas pipeline facilities that operators should immediately...

  15. 75 FR 67450 - Pipeline Safety: Control Room Management Implementation Workshop

    Science.gov (United States)

    2010-11-02

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Control Room Management... of Pipeline Safety Representatives (NAPSR) on the implementation of pipeline control room management. The workshop is intended to foster an understanding of the Control Room Management Rule issued...

  16. Emergency preparedness of OSBRA Pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Magalhaes, Milton P.; Torres, Carlos A.R.; Almeida, Francisco J.C. [TRANSPETRO, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper presents the experience of PETROBRAS Transporte S. A. - TRANSPETRO in the preparation for emergencies in the OSBRA pipeline, showing specific aspects and solutions developed. The company has a standardized approach for the emergency management, based on risk analysis studies, risk management plan and contingency plans. To cover almost 1,000 km of pipeline, the Company avails of Emergency Response Centers and Environmental Defense Center, located at strategic points. In order to achieve preparation, fire fighting training and oil leakage elimination training are provided. Additionally, simulation exercises are performed, following a schedule worked out according to specific criteria and guidelines. As a conclusion, a picture is presented of the evolution of the preparation for emergencies in the OSBRA System which bears the enormous responsibility of transporting flammable products for almost 1,000 km of pipeline, crossing 40 municipalities, 3 states and the Federal District. (author)

  17. Method and system for pipeline communication

    Science.gov (United States)

    Richardson; John G.

    2008-01-29

    A pipeline communication system and method includes a pipeline having a surface extending along at least a portion of the length of the pipeline. A conductive bus is formed to and extends along a portion of the surface of the pipeline. The conductive bus includes a first conductive trace and a second conductive trace with the first and second conductive traces being adapted to conformally couple with a pipeline at the surface extending along at least a portion of the length of the pipeline. A transmitter for sending information along the conductive bus on the pipeline is coupled thereto and a receiver for receiving the information from the conductive bus on the pipeline is also couple to the conductive bus.

  18. Capsule- and disk-filter procedure

    Science.gov (United States)

    Skrobialowski, Stanley C.

    2016-01-01

    Capsule and disk filters are disposable, self-contained units composed of a pleated or woven filter medium encased in a polypropylene or other plastic housing that can be connected inline to a sample-delivery system (such as a submersible or peristaltic pump) that generates sufficient pressure (positive or negative) to force water through the filter. Filter media are available in several pore sizes, but 0.45 µm is the pore size used routinely for most studies at this time. Capsule or disk filters (table 5.2.1.A.1) are required routinely for most studies when filtering samples for trace-element analyses and are recommended when filtering samples for major-ion or other inorganic-constituent analyses.

  19. The Alaskan gas pipeline conflict

    Energy Technology Data Exchange (ETDEWEB)

    Savich, P.; Fraser, N.M.; Hippel, K.W.

    1983-03-01

    A new conflict analysis technique is employed to study the dispute surrounding the selection of a natural gas pipeline route to transport gas from the American state of Alaska and also northern Canada to southern markets in the United States and Canada. The improved metagame analysis algorithm is the type of conflict analysis method that is used for providing a framework to study systematically the Alaskan gas pipeline controversy and to put the historical information into proper perspective. In addition, the methodology is utilized for predicting the possible feasible political solutions to the conflict.

  20. 78 FR 41496 - Pipeline Safety: Meetings of the Gas and Liquid Pipeline Advisory Committees

    Science.gov (United States)

    2013-07-10

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Meetings of the Gas and Liquid... for natural gas pipelines and for hazardous liquid pipelines. Both committees were established under.... ACTION: Notice of advisory committee meeting. SUMMARY: This notice announces a public meeting of the...

  1. 76 FR 29333 - Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical...

    Science.gov (United States)

    2011-05-20

    ... review DOT's complete Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical Hazardous Liquid Pipeline Safety Standards Committee...

  2. Guideline for Capsule Endoscopy: Obscure Gastrointestinal Bleeding

    OpenAIRE

    Shim, Ki-Nam; Moon, Jeong Seop; Chang, Dong Kyung; Do, Jae Hyuk; Kim, Ji Hyun; Min, Byung Hoon; Jeon, Seong Ran; Kim, Jin-Oh; Choi, Myung-Gyu; ,

    2013-01-01

    Capsule endoscopy (CE) is considered as a noninvasive and reliable diagnostic tool of examining the entire small bowel. CE has been performed frequently at many medical centers in South Korea; however, there is no evidence-based CE guideline for adequate diagnostic approaches. To provide accurate information and suggest correct testing approaches for small bowel disease, the guideline on CE was developed by the Korean Gut Image Study Group, a part of the Korean Society of Gastrointestinal End...

  3. Resorcinarenes are hexameric capsules in solution

    OpenAIRE

    Evan-Salem, Tamar; Baruch, Inbal; Avram, Liat; Cohen, Yoram; Palmer, Liam C.; Rebek, Julius

    2006-01-01

    The host–guest complexes of resorcin[4]arenes with small molecules in organic solutions are examined using modern NMR spectroscopic methods. The complexation of glutaric acid and β-methyl d-glucopyranoside in chloroform were investigated through 2D COSY, 2D NOESY, 1D NOE, and diffusion-ordered NMR spectroscopy (DOSY) techniques. These methods indicate that the complex is a self-assembled capsule composed of six resorcinarenes that surround six guest molecules of glutaric acid or three molecul...

  4. California Natural Gas Pipelines: A Brief Guide

    Energy Technology Data Exchange (ETDEWEB)

    Neuscamman, Stephanie [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Price, Don [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pezzola, Genny [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Glascoe, Lee [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-01-22

    The purpose of this document is to familiarize the reader with the general configuration and operation of the natural gas pipelines in California and to discuss potential LLNL contributions that would support the Partnership for the 21st Century collaboration. First, pipeline infrastructure will be reviewed. Then, recent pipeline events will be examined. Selected current pipeline industry research will be summarized. Finally, industry acronyms are listed for reference.

  5. Blowdown Simulation of CO2 Pipelines

    OpenAIRE

    Collard, A

    2015-01-01

    Pipelines are the most practical option for transporting large volumes of captured CO2 to appropriate storage sites as part of the Carbon Capture and Storage (CCS) process. Proper maintenance, including periodic blowdown of pipelines or pipeline sections, is necessary for their safe operation, a pre-requisite for the public acceptance of CCS. Given the relatively high Joule-Thomson coefficient of CO2, blowdown can present significant risks to pipeline infrastructure. Depressurisation will res...

  6. Anping-Nanjing Gas Pipeline Formally Commissioned

    Institute of Scientific and Technical Information of China (English)

    Zhang Jicheng

    2006-01-01

    @@ On January 17, 2006, gas from Changqing gasfield in northern Shaanxi Province was poured into Anping-Nanjing gas pipeline, marking that the trunk line was successfully brought into operation and the West-East Gas Pipeline and No.2 Shaanxi-Beijing pipeline were successfully connected. Pressure was boosted immediately after its commissioning to ensure gas supply to Beijing and Shanghai. Gas supply to part areas along this pipeline will begin by May, 2006.

  7. Collapse of experimental capsules under external pressure

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data.

  8. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  9. Research on Pipeline Holdup Measurement Technology

    Institute of Scientific and Technical Information of China (English)

    LU; Wen-guang; XU; Zheng; CHENG; Yi-mei; SUI; Hong-zhi; YIN; Hong-he

    2012-01-01

    <正>Some of the nuclear material could be deposited in the pipeline system of the nuclear facilities in the operation process. That kind of nuclear materials in the pipeline are called holdup. The measurement of pipeline holdup is not only important for the nuclear material accounting and control of facilities, but also important for the safe operation of facilities.

  10. Sulfide stress cracking of pipeline steels

    International Nuclear Information System (INIS)

    The problem of the sulfide stress corrosion cracking of pipeline steels and their welded joints have been presented for pipeline steels. Results of hydrogen sulfide stress cracking inhibitors and corrosion inhibitors of three types protective actions on pipeline steels of two grades petroleum range of products are given. (author)

  11. 49 CFR 195.422 - Pipeline repairs.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipeline repairs. 195.422 Section 195.422 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  12. Smart Image Sensor with Integrated Low Complexity Image Processing for Wireless Endoscope Capsules

    Institute of Scientific and Technical Information of China (English)

    LI Xiaowen; ZHANG Milin; WANG Zhihua; Amine Bermak

    2009-01-01

    A smart image sensor was developed which integrates a digital pixel image sensor array with an image processor, designed for wireless endoscope capsules. The camera-on-a-chip architecture and its on-chip functionality facilitate the design of the packaging and power consumption of the integrated capsule. The power reduction techniques were carried out at both the architectural and circuit level. Gray coding and power gating in the sensor array to eliminate almost 50% of the switch activity on the data bus and more than 99% of the power dissipation in each pixel at a transmitting rate of 2 frames per second. Filtering and compression in the processor reduces the data transmission by more than 2/3. A parallel fully pipelined ar-chitecture with a dedicated clock management scheme was implemented in the JPEG-LS engine to reduce the power consumption by 15.7%. The smart sensor has been implemented in 0.18 μm CMOS technology.

  13. A Novel Method to Enhance Pipeline Trajectory Determination Using Pipeline Junctions

    OpenAIRE

    Hussein Sahli; Naser El-Sheimy

    2016-01-01

    Pipeline inspection gauges (pigs) have been used for many years to perform various maintenance operations in oil and gas pipelines. Different pipeline parameters can be inspected during the pig journey. Although pigs use many sensors to detect the required pipeline parameters, matching these data with the corresponding pipeline location is considered a very important parameter. High-end, tactical-grade inertial measurement units (IMUs) are used in pigging applications to locate the detected p...

  14. Internal corrosion of transmission pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Elm, T. [Enbridge Pipelines Inc., Calgary, AB (Canada); Jack, T. [Nova Chemicals Ltd., Calgary, AB (Canada); Boivin, J. [Cormetrics Ltd., Calgary, AB (Canada)

    2003-07-01

    The presentations by Working Group 13 focused on the factors influencing internal pipeline corrosion failures as well as the challenges facing both oil and gas operators to mitigate and monitor internal corrosion. Some of the tools needed to effectively treat the internal corrosion life cycle were also discussed. It was noted that upstream pipelines face many of the same issues as transmission lines, but under different operating conditions. It was emphasized that the overall risk of corrosion is high, but the probability is often under-appreciated even in light of the consequences to public safety, environmental damage and loss of income. The root cause of internal corrosion is water. Areas where water collects are subject to ongoing attack by dissolved corrosive gases, dissolved salts, and corrosive bacteria. Risk assessment is useful in identifying critical points, determining mitigation requirements, and choosing an inspection method. Monitoring with fibre optic sensor technology is useful because it helps identify the source of the problem and helps regulate mitigation activities. It was emphasized that it is equally important to monitor the growth of corrosion features. In the United States, recent failures of gas transmission pipelines due to internal corrosion have resulted in more stringent regulations. Many failures have been prevented because of in-line inspection and pigging. The effect of transporting other substances, such as hydrogen or ethanol, in pipelines was also discussed. tabs., figs.

  15. The Classroom to Prison Pipeline

    Science.gov (United States)

    Christensen, Linda

    2012-01-01

    The school-to-prison pipeline doesn't just begin with cops in the hallways and zero tolerance discipline policies. It begins when teachers fail to create a curriculum and a pedagogy that connects with students, that takes them seriously as intellectuals, that lets students know teachers care about them, that gives them the chance to channel their…

  16. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  17. Capsule formation and asymbiotic seed germination in some hybrids of Phalaenopsis, influenced by pollination season and capsule maturity.

    Science.gov (United States)

    Balilashaki, Khosro; Gantait, Saikat; Naderi, Roohangiz; Vahedi, Maryam

    2015-07-01

    We explored the influence of pollination season and maturity of capsule on post-pollination capsule formation and in vitro asymbiotic seed germination, respectively. Three Phalaenopsis orchid hybrids, namely, 'Athens', 'Moscow' and 'Lusaka' flowers were artificially self-pollinated during winter, spring, summer and fall seasons and the impact of the pollination seasons was evident during capsule formation. It was observed that winter was the most suitable season for pollination of all the three Phalanaeopsis hybrids resulting in 80-88 % capsule formation. During summer, the pollination success rate was 24-28 %, but resulted in successful capsule formation. Season of pollination further delimited the germination efficiency of seeds harvested from capsules of variable maturity levels. Invariably, seeds collected from winter-pollinated capsules performed best in germination compared to other seasons, for instance, 'Moscow' seeds took less than 14 days to germinate from capsules developed following winter-pollination. Regarding the influence of capsule maturity on seed germination, we observed that seeds derived from 5-month mature capsules, invariably took least time to germinate than that of the 3-month or 7-month in all three hybrids, e.g., for 'Moscow' it was 13.9 days with a maximum of 90.3 % germination.

  18. Shipbuilding pipeline production quality improvement

    Directory of Open Access Journals (Sweden)

    T. Buksa

    2010-06-01

    Full Text Available Purpose: The pipeline production is one of major processes in shipbuilding industry. Quality improvement and risk assessment in this process can yield significant savings, both in terms of internal quality costs as well as in terms of customer satisfactions.Design/methodology/approach: Shipbuilding pipeline production quality improvement has been carried out by application of FMEA (Failure Mode and Effect Analysis method. For the successful implementation of FMEA method it is necessary to identify process failure modes or possibility of the appearance of non-compliance, as well as their possible causes. For qualitative analysis of key input variables of the process, in the paper is used Ishikawa diagram and p-chart.Findings: It is shown that proposed approach to risk assessment in shipbuilding pipeline production is applicable to real casa scenario. The analysis has identified the points in the process with the highest probability of occurrence of nonconformities, or the highest risk for error.Research limitations/implications: As the experimenting has been conducted in shipyard, within production process, research schedule must have been set in accordance with production pace. Also, due to character of production process the data collecting was adopted to the production plan in that particular moment.Practical implications: Dealing with causes of potential nonconformities in the process can significantly contribute to the reliability and robustness of the process. Corrective actions that have been taken based on results of analysis significantly contributed to the level of quality in the pipeline production process.Originality/value: The pepper is dealing with a well known method applied in different production environment that are mostly conservative in production approach. It was shown that successful application of proposed approach can yield benefits especially in improved quality of produced pipelines within shipbuilding industry.

  19. Customer service drives pipelines' reorganization

    International Nuclear Information System (INIS)

    The concept behind formation of Enron Transportation and Storage tells plenty about this new gas industry. When executives at the Enron Gas Pipeline Group considered plans last year to streamline operations by merging the support functions of Transwestern Pipeline and their other wholly owned pipeline company, Northern Natural Gas, seamless customer service was foremost on their agenda. Instead of worrying about whether employees would favor one pipeline over the other, perhaps to the detriment of customers, they simply created a new organization that everyone would swear the same allegiance to. The 17,000-mile, 4.1 Bcf/d Northern system serves the upper Midwest market and two major expansion projects were completed there last year. Transwestern is a 2,700-mile system with an eastward capacity of 1 Bcf/d and westward of 1.5 Bcf/, that traditionally served California markets. It also ties into Texas intrastate markets and, thanks to expansion of the San Juan lateral, to southern Rocky Mountain supplies. Although Enron Corp. continues to position itself as a full-service energy company, the Gas Pipeline Group continues to fuel much of corporate's net income, which was $584 million last year. With ET and S comprising a significant portion of GPG's income, it was vital that the merger of Northern's 950 employees with Transwestern's 250 indeed be a seamless one. It was not easy either psychologically or geographically with main offices in Omaha, NE and Houston as well as operations centers in Minneapolis, MN; Amarillo, TX; W. Des Moines, IA; and Albuquerque, NM. But the results have been gratifying, according to William R. Cordes, President of ET and S and Nancy L. Gardner, Executive Vice President of Strategic Initiatives

  20. Optical Fiber Pipeline Security Forewarning System

    Institute of Scientific and Technical Information of China (English)

    Jiang Qishan; Ren Ruijun; Ren Peikui

    2010-01-01

    @@ With the rapid development of China's economy,such incidents occurring to oil & gas pipelines as industrial and agricultural production,natural disasters,oil stealing,etc.have been prevailing and brought negative influences to the normal operation of pipelines.On account of all such destructive activities,firstly the soil around the pipeline should be vibrated,and then the cable laid in the pipe trench could respond to the vibration.Using this technology,the Department of Science & Technology of CNPC has embarked on the research of relevant equipment to monitor pipeline activities along the pipeline since 2001.

  1. A Review of Locomotion Systems for Capsule Endoscopy.

    Science.gov (United States)

    Liu, Lejie; Towfighian, Shahrzad; Hila, Amine

    2015-01-01

    Wireless capsule endoscopy for gastrointestinal (GI) tract is a modern technology that has the potential to replace conventional endoscopy techniques. Capsule endoscopy is a pill-shaped device embedded with a camera, a coin battery, and a data transfer. Without a locomotion system, this capsule endoscopy can only passively travel inside the GI tract via natural peristalsis, thus causing several disadvantages such as inability to control and stop, and risk of capsule retention. Therefore, a locomotion system needs to be added to optimize the current capsule endoscopy. This review summarizes the state-of-the-art locomotion methods along with the desired locomotion features such as size, speed, power, and temperature and compares the properties of different methods. In addition, properties and motility mechanisms of the GI tract are described. The main purpose of this review is to understand the features of GI tract and diverse locomotion methods in order to create a future capsule endoscopy compatible with GI tract properties. PMID:26292162

  2. Role of shocks and mix caused by capsule defects

    Science.gov (United States)

    Bradley, P. A.; Cobble, J. A.; Tregillis, I. L.; Schmitt, M. J.; Obrey, K. D.; Glebov, V.; Batha, S. H.; Magelssen, G. R.; Fincke, J. R.; Hsu, S. C.; Krasheninnikova, N. S.; Murphy, T. J.; Wysocki, F. J.

    2012-09-01

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The "perfect" capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  3. Expanding role of capsule endoscopy in inflammatory bowel disease

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Capsule endoscopy has been shown to detect small bowel inflammatory changes better than any other imaging modality. Selection criteria have been optimized to increase the yield of capsule endoscopy in patients suspected to have Crohn's disease. Capsule endoscopy allows for earlier diagnosis of Crohn's disease of the small bowel and improved diagnosis of colitis in patients where it is unclear if they suffer from Crohn's or ulcerative colitis. A test capsule is available to assess for small bowel strictures and thus avoid capsule retention. A common language has been developed and a new scoring index will be added to capsule software. It is envisioned that the manner in which we treat Crohn's disease in the future will change, based on earlier diagnosis and treatment aimed at mucosal healing rather than symptom improvement.

  4. The motion of a deforming capsule through a corner

    CERN Document Server

    Zhu, Lailai

    2014-01-01

    A three-dimensional deformable capsule convected through a channel/duct with a corner is studied via numerical simulations using an accelerated boundary integral method adapted to general geometries. A global spectral method is adopted to resolve the dynamics of the capsule's membrane developing elastic tensions according to the Neo-Hookean constitutive law and bending moments in an inertialess flow. The simulations show that the trajectory of the capsule closely follows the underlying streamlines and the deformation of the capsule induces an anti-clockwise rotation of its material points with respect to the travelling direction. The surface area, principle tension and elastic energy of the capsule increase around the corner. Their temporal evolutions are characterised by a clear phase delay and the loss of time-reversal symmetry of Stokes flow due to the elasticity of membrane. The capsule centroid velocity decreases approaching the corner as the mean flow does while a velocity overshoot is observed past the...

  5. Role of shocks and mix caused by capsule defects

    International Nuclear Information System (INIS)

    An Eulerian code with a turbulent mix model is used to model a set of plastic (CH) ablator capsules with and without equatorial grooves. The “perfect” capsule results were used to calibrate simulations of capsules with equatorial grooves of different depths that provided information on increasingly perturbed implosions. Simulations with a turbulence model were able to calculate the same yield over mix (YOM) ratio (experiment/mix simulation) of 0.2 to 0.3 for thin (8-μm thick) and thick shell (15-μm thick) capsules with no grooves and thin capsules with shallow grooves. When the capsules have deep grooves, the YOM ratio increases to greater than unity, probably because the deformed shocks focus too strongly on the symmetry axis in our two-dimensional simulations. This is supported by a comparison of simulated and experimental x-ray images.

  6. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  7. Anterior capsule tear after laser iridotomy complicating phacoemulsification

    OpenAIRE

    Vivien Cherng Hui, Yip; Sanjay, Srinivasan; Benjamin Chong-Ming, Chang

    2011-01-01

    A 70-year-old Indian lady had a history of bilateral laser peripheral iridotomy (LPI) for primary angle closure. Subsequently she developed cataract in both the eyes. Right eye cataract surgery was complicated by an anterior capsule rupture, which was discovered intra-operatively at the site of the LPI. Trypan blue was used to stain the anterior capsule to delineate the anterior capsule defect. An attempt at continuous curvilinear capsulorhexis was unsuccessful, and the anterior capsulotomy w...

  8. Fibrous Calcareous Concretions in the Capsules of Human Pineal Glands

    OpenAIRE

    Kodaka Tetsuo; Mori Ryoichi; Ezure Hiromitsu; Ito Junji; Otsuka Naruhito

    2013-01-01

    We examined calcareous concretions in the capsule of 15 human pineal glands containing a large amount of the concretions in the matrix. The capsule concretions, brown to blackish-brown in color and/or translucent, were smaller than the matrix concretions, which were yellowish-white. The matrix concretions showed the typical mulberry-shaped overall appearance with scallop-shaped concentric laminations of non-fibrous structures, but the capsule concretions, which also contained Ca and P, showed...

  9. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  10. Upstream pipelines : inspection, corrosion and integrity management

    Energy Technology Data Exchange (ETDEWEB)

    Paez, J.; Stephenson, M. [Talisman Energy Inc., Calgary, AB (Canada)] (comps.)

    2009-07-01

    Accurate inspection techniques are needed to ensure the integrity of pipelines. This working group discussed methods of reducing pipeline failures for a variety of pipes. A summary of recent pipeline performance statistics was presented, as well as details of third party damage and fiberglass pipe failures. A batch inhibitor joint industry project was described. The session demonstrated that integrity program need to be developed at the field-level as well as at the upper management level. Fiberglass pipeline failures are significant problem for pipeline operators. Corrosion monitoring, pigging and specific budgets are needed in order to ensure the successful management of pipeline integrity. New software developed to predict pipeline corrosion rates was discussed, and methods of determining mole fractions and flow regimes were presented. The sessions included updates from regulators and standards agencies as well as discussions of best practices, regulations, codes and standards related to pipeline integrity. The working group was divided into 4 sessions: (1) updates since 2007 with input from the Canadian Association of Petroleum Producers (CAPP) and the Upstream Pipeline Integrity Management Association (UPIMA); (2) integrity of non-metallic pipelines; (3) upstream pipeline integrity issues; and (4) hot topics. tabs., figs.

  11. The MIRI Medium Resolution Spectrometer calibration pipeline

    CERN Document Server

    Labiano, A; Bailey, J I; Beard, S; Dicken, D; García-Marín, M; Geers, V; Glasse, A; Glauser, A; Gordon, K; Justtanont, K; Klaassen, P; Lahuis, F; Law, D; Morrison, J; Müller, M; Rieke, G; Vandenbussche, B; Wright, G

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments, such as fringe corrections and wavelength offsets, with different algorithms for point source or extended source data. The MRS pipeline has also two different variants: the baseline pipeline, optimized for most foreseen science cases, and the optimal pipeline, where extra steps will be needed for specific science cases. This paper provides a comprehensive description of the MRS Calibration Pipeline from uncalibrated slope images to final scientific products, with brief descriptions of its algorithms, input and output data, and the accessory data and calibration data products necessary to run the pipeline.

  12. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency.

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, Debbie (LLNL); Vesey, Roger Alan; Cochrane, Kyle Robert (KTech); Nikroo, A. (General Atomics); Bennett, Guy R.; Schroen, Diana Grace (Schafer); Ruggles, Laurence E.; Porter, John L.; Streit, Jon (Schafer); Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-11-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence [1]. Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR.

  13. Preparation of alginate-gelatin capsules and its properties

    Institute of Scientific and Technical Information of China (English)

    Xiao-yan LI; Xi-guang CHEN; Cheng-sheng LIU; Chen-guang LIU; Yu-ping XUE

    2008-01-01

    Capsules based on alginate and gelatin prepared by extrusion method could increase the cell numbers of Lactobacillus casei ATCC 393 to be 108 CFU·9-1 in the wet state of the capsules. The capsules were spherical, smooth-surfaced and non-aggregated with a diameter of (4.0±0.3) mm. The behavior of the samples were quite similar at low relative humidity (33%, 52%) and the ratio of weight change reached 93%. Four kinds of capsules in simulated gastric fluid (SGF) exhibited shrinkage while the beads eroded accompanied with slight swelling in simulated intestinal fluid (SIF). The pH values affected the stability of the capsules and with the increase in pH, the capsules chan-ged from shrank then swelled and finally, broke into pieces. The capsules behaved differently under different ion intens-ities and the introduction of gelatin weakened the stability of capsules compared with the alginate ones. Cells of L. casei ATCC 393 could be continuously released from the capsules in the simulated gastrointestinal tract (GIT) and the release amounts and speeds in SIF were much higher and faster than those in SGF.

  14. Small intestinal model for electrically propelled capsule endoscopy

    Directory of Open Access Journals (Sweden)

    Woo Sang Hyo

    2011-12-01

    Full Text Available Abstract The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule.

  15. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  16. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  17. Postirradiation examination of capsule GF-4

    International Nuclear Information System (INIS)

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC2 and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO2 fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted

  18. Analytic prognostic for petrochemical pipelines

    CERN Document Server

    Jaoude, Abdo Abou; El-Tawil, Khaled; Noura, Hassan; Ouladsine, Mustapha

    2012-01-01

    Pipelines tubes are part of vital mechanical systems largely used in petrochemical industries. They serve to transport natural gases or liquids. They are cylindrical tubes and are submitted to the risks of corrosion due to high PH concentrations of the transported liquids in addition to fatigue cracks due to the alternation of pressure-depression of gas along the time, initiating therefore in the tubes body micro-cracks that can propagate abruptly to lead to failure. The development of the prognostic process for such systems increases largely their performance and their availability, as well decreases the global cost of their missions. Therefore, this paper deals with a new prognostic approach to improve the performance of these pipelines. Only the first mode of crack, that is, the opening mode, is considered.

  19. New reduced volume preparation regimen in colon capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    Yasuo Kakugawa; Kazuhide Higuchi; Shinji Tanaka; Hideki Ishikawa; Hisao Tajiri; Yutaka Saito; Shoichi Saito; Kenji Watanabe; Naoki Ohmiya; Mitsuyuki Murano; Shiro Oka; Tetsuo Arakawa; Hidemi Goto

    2012-01-01

    AIM:To evaluate the effectiveness of our proposed bowel preparation method for colon capsule endoscopy.METHODS:A pilot,multicenter,randomized controlled trial compared our proposed "reduced volume method" (group A) with the "conventional volume method" (group B) preparation regimens.Group A did not drink polyethylene glycol electrolyte lavage solution (PEGELS) the day before the capsule procedure,while group B drank 2 L.During the procedure day,groups A and B drank 2 L and 1 L of PEG-ELS,respectively,and swallowed the colon capsule (PillCam COLON(R) capsule).Two hours later the first booster of 100 g magnesium citrate mixed with 900 mL water was administered to both groups,and the second booster was administered six hours post capsule ingestion as long as the capsule had not been excreted by that time.Capsule videos were reviewed for grading of cleansing level.RESULTS:Sixty-four subjects were enrolled,with results from 60 analyzed.Groups A and B included 31 and 29 subjects,respectively.Twenty-nine (94%) subjects in group A and 25 (86%) subjects in group B had adequate bowel preparation (ns).Twenty-two (71%) of the 31 subjects in group A excreted the capsule within its battery life compared to 16 (55%) of the 29 subjects in group B (ns).Of the remaining 22 subjects whose capsules were not excreted within the battery life,all of the capsules reached the left side colon before they stopped functioning.A single adverse event was reported in one subject who had mild symptoms of nausea and vomiting one hour after starting to drink PEG-ELS,due to ingesting the PEG-ELS faster than recommended.CONCLUSION:Our proposed reduced volume bowel preparation method for colon capsule without PEG-ELS during the days before the procedure was as effective as the conventional volume method.

  20. Pressure equivalents in industrial gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Metel' kov, V.P.

    1980-01-01

    Pressure equivalence is a mathematical concept used to explain action and load parameters for pipelines. These two parameters are congruent to pressures encountered in pipelines. The research examined pressure equivalence in 820 by 8 millimeter pipelines in the Samotlor region and took into account the influence of support jams during first and second category jamming. It was determined that the absolute dimensions to pressure pulsations were significantly larger than plus or minus ten percent from (Prab) and even exceeded (Prab) in certain instances. The ratios at which (Prab) can be exceeded vary with relation to the jam supports and the maximum variations stem from yield in the metal pipelines themselves. The above concepts can be used to study the effects of pressure equivalence upon loads and pressures of Samotlor field pipelines and to select appropriate pipeline planning and construction methods. The conclusions drawn are valid for industrial surface pipelines used at below limit pressures. Annular and daily temperature variations in the outside air are considered with regard to their effect upon the pressure equivalence within the lower sections of the pipeline. Deviations here have been noted to exceed (formula). It was observed that in the case of underground pipelines, operated at below limit pressures, pressure equivalence occured in the upper section of the pipeline.

  1. Semiautomated measurement of pipeline defects

    International Nuclear Information System (INIS)

    The basic technical parameters and properties are given for a newly developed ultrasonic nondestructive testing device for the detection of defects on the inner surface of austenitic tubes of WWER nuclear power plant primary circuits. In addition to the electronic part of the four-channel test equipment, the manipulator and probes have also been designed, and their function is described. The manipulator is designed for measurement on straight pipeline segments of 500 mm inner dia. (B.S.). 4 figs

  2. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  3. Scheimpflug imaging of pediatric posterior capsule rupture

    Directory of Open Access Journals (Sweden)

    Grewal Dilraj

    2009-01-01

    Full Text Available We report a case of an 11-year-old boy who presented two days after blunt trauma to the left eye with a slingshot. On examination his best corrected visual acuity (BCVA was 20/20 in the right eye and 20/400 in the left eye. Slit-lamp examination of the left eye revealed a Vossius ring, traumatic cataract, traumatic posterior capsule tear (PCT. The contour of the posterior capsule bulge corresponded to the edges of the PCT. Rotating Scheimpflug imaging (Pentacam 70700:Oculus, Wetzlar Germany confirmed the traumatic cataract in the region of the PCT visualized as increased lens density at the cortex-vitreous interface. The extent of the PCT in the greatest and least dimensions was documented before and after intraocular lens (IOL implantation. Intra-operatively, the PCT was evident and phaco-emulsification with an IOL implant was performed. Postoperatively, his BCVA improved to 20/20 in the left eye with a well-centered in-the-bag IOL as found on slit-lamp and Scheimpflug images.

  4. STATUS AND PROSPECT OF OIL AND GAS PIPELINES IN CHINA

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ With the exploration and development of natural gas and the increase of crude oil import, the industry of China's Oil and Gas Pipelines has witnessed rapid development. Especially the gas pipeline industry is entering a peak period of development. Thanks to the completion and operation of large-scale pipeline projects including West-East Gas Transportation Pipeline project,Shanxi-Beijing Gas Pipeline Ⅱ, Ji-Ning Pipeline,Huaiyang-Wuhan Pipeline, Guangdong LNG Pipeline,Western Pipeline and Pearl River Delta Oil Product Pipeline, many trans-regional gas and oil pipeline networks with initial scale have been gradually established and improved in China. Meanwhile, the metallurgy,manufacturing and construction level of pipelines has been greatly developed, achieving world top level. The next five years is still a peak period of development for China's gas and oil pipeline industry which will enjoy a broader prospect.

  5. Quality evaluation of simvastatin compounded capsules

    Directory of Open Access Journals (Sweden)

    Flávia Dias Marques-Marinho

    2011-09-01

    Full Text Available Simvastatin is commercially available as tablets and compounded capsules in Brazil. Very few reports regarding these capsules' quality, and consequently their efficacy, are available. The pharmaceutical quality of 30 batches of 20 mg simvastatin capsules from the market was evaluated by weight determination, content uniformity, disintegration (Brazilian Pharmacopeia, assay and dissolution test (USP32 tablet monograph. A HPLC method was developed for assay, content uniformity and dissolution test, and specifications were also established. Out of the 30 batches evaluated, 29 showed capsule disintegration within 45 min and individual weight variation was within ±10% or ±7.5% relative to average weight, for 300 mg, respectively. Only 27 batches met dissolution test criteria with values >80% of the labeled amount in 45 min; 21 batches showed simvastatin content between 90.0-110.0% of the labeled amount and 19 batches had at least 9 out of 10 capsules with content uniformity values between 85.0-115.0% of the labeled amount with RSDNo Brasil, a sinvastatina está comercialmente disponível na forma de comprimidos e cápsulas manipuladas. Poucos relatos estão disponíveis sobre a qualidade e, consequentemente, a eficácia dessas cápsulas. A qualidade de 30 lotes de sinvastatina 20 mg cápsulas do mercado foi avaliada através da determinação de peso, uniformidade de conteúdo, desintegração (Farmacopéia Brasileira, doseamento e teste de dissolução (monografia comprimidos USP32. Método por CLAE foi desenvolvido para o doseamento, uniformidade de conteúdo e teste de dissolução; além disso, especificações foram estabelecidas. Dos 30 lotes avaliados, 29 apresentaram desintegração da cápsula até 45 min e a variação do peso individual foi ± 10% ou ± 7,5% em relação ao peso médio, se 300 mg, respectivamente. Apenas 27 lotes preencheram os critérios do teste de dissolução com valores > 80% da quantidade rotulada, em 45 min, 21

  6. Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis

    OpenAIRE

    Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.; Petersen, Fernanda C

    2014-01-01

    The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mut...

  7. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...

  8. Highly active antibody-modified magnetic polyelectrolyte capsules.

    Science.gov (United States)

    Valdepérez, Daniel; Del Pino, Pablo; Sánchez, Lourdes; Parak, Wolfgang J; Pelaz, Beatriz

    2016-07-15

    Polyelectrolyte hollow capsules are versatile platforms typically used for encapsulation of a wide variety of macromolecules in their cavity. The polymer shell of these capsules as composed by alternating layers of oppositely charged polyelectrolytes also allows for adding additional functionalities. The properties of the shell can be for example engineered by trapping different nanoparticles in-between the shell layers and/or by attaching bioactive molecules such as antibodies to the outermost layer. Herein, iron oxide NPs were inmobilized into the shell of polyelectrolyte capsules and the outermost layer of the shell was covalently modified with anti peroxidase antibodies. These capsules act as prototype model system, aiming to obtain a microstructure with the potential capability to specifically recognize and separate macromolecules. Due to the magnetic nanoparticles in the capsule shell, the capsules together with the attached target might be extracted by magnetic field gradients. Here we verified this approach by extracting horseradish peroxidase from a solution through magnetic separation with capsules bearing antibodies against horseradish peroxidase. The bioactivity of the capsules and the high degree of specific antibody functionalization were confirmed and quantified through an enzymatic reaction mediated by the extracted horseradish peroxidase. PMID:27089014

  9. Diamagnetically stabilized levitation control of an intraluminal magnetic capsule.

    Science.gov (United States)

    Lam, Michael; Mintchev, Martin

    2009-08-01

    Controlled navigation promotes full utilization of capsule endoscopy for reliable real-time diagnosis in the gastrointestinal (GI) tract, but intermittent natural peristalsis can disturb the navigational control, destabilize the capsule and take it out of levitation. The focus of the present work was to develop an economical and effective real-time magnetic capsule-guiding system that can operate in the presence of naturally existing peristalsis while retaining navigational control. A real-size magnetic navigation system that can handle peristaltic forces of up to 1.5 N was designed utilizing the computer-aided design (CAD) system Maxwell 3D (Ansoft, Pittsburg, PA) and was verified using a small-size physical experimental setup. The proposed system contains a pair of 50 cm diameter, 10,000-turn copper electromagnets with a 10 cm x 10 cm ferrous core driven by currents of up to 300 A and can successfully maintain position control over the levitating capsule during peristalsis. The addition of bismuth diamagnetic casing for stabilizing the levitating capsule was also studied. A modeled magnetic field around the diamagnetically cased permanent magnet was shown to be redistributed aligning its interaction with the external electromagnets, thus stabilizing the levitating capsule. In summary, a custom-designed diamagnetically facilitated capsule navigation system can successfully steer an intraluminal magnet-carrying capsule. PMID:19550023

  10. 1964 computer run on a laser-imploded capsule

    International Nuclear Information System (INIS)

    WAZER Alchemy 7b (WA-7b) is a WAZER calculation of a laser-driven micro-implosion of a spherical capsule consisting of a thin gold pusher surrounded by a thick (frozen) deuterium ablator. The properties of the target capsule and the shape of the laser pulse used to irradiate it are described

  11. Experimental modulation of capsule size in Cryptococcus neoformans

    Directory of Open Access Journals (Sweden)

    Zaragoza Oscar

    2004-01-01

    Full Text Available Experimental modulation of capsule size is an important technique for the study of the virulence of the encapsulated pathogen Cryptococcus neoformans. In this paper, we summarize the techniques available for experimental modulation of capsule size in this yeast and describe improved methods to induce capsule size changes. The response of the yeast to the various stimuli is highly dependent on the cryptococcal strain. A high CO2 atmosphere and a low iron concentration have been used classically to increase capsule size. Unfortunately, these stimuli are not reliable for inducing capsular enlargement in all strains. Recently we have identified new and simpler conditions for inducing capsule enlargement that consistently elicited this effect. Specifically, we noted that mammalian serum or diluted Sabouraud broth in MOPS buffer pH 7.3 efficiently induced capsule growth. Media that slowed the growth rate of the yeast correlated with an increase in capsule size. Finally, we summarize the most commonly used media that induce capsule growth in C. neoformans.

  12. Design of capsules capable of argon-filling

    International Nuclear Information System (INIS)

    The possibility of the use of polycarbosilane capsules as fuel container in inertial confinement fusion experiments was analyzed in the paper. Primary study indicates that the polycarbosilane capsules can be filled with argon by means of diffusion and possess reasonable retention time for deuterium. (author)

  13. 76 FR 70217 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2011-11-10

    ... ``Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements.'' That final rule... 72878), titled ``Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements... the Federal Register of its intent to create a national registry of pipeline and liquefied natural...

  14. FPGA Implementation of Wave Pipelining CORDIC Algorithms

    Institute of Scientific and Technical Information of China (English)

    CUI Wei

    2008-01-01

    The implementation of the coordinate rotational digital computer (CORDIC) algorithm with wave pipelining technique on field programmable gate array (FPGA) is described. All data in FPGA-based wave pipelining pass through a number of logic gates, in the same way that all data pass through the same number of registers in a conventional pipeline. Moreover, all paths are routed using identical routing resources. The manual placement, timing driven routing and timing analyzing techniques are applied to optimize the layout for achieving good path balance. Experimental results show that a 256-LUT logic depth circuit mapped on XC4VLX15-12 runs as high as 330MHz, which is a little lower than the speed of 336MHz based on the conventional 16-stage pipelining in the same chip. The latency of the wave pipelining circuit is 30.3ns, which is 36.4% shorter than the latency of 16-stage conventional pipelining circuit.

  15. Development of high productivity pipeline girth welding

    International Nuclear Information System (INIS)

    The trend for increased oil and gas consumption implies a growth of long-distance pipeline installations. Welding is a critical factor in the installation of pipelines, both onshore and offshore, and the rate at which the pipeline can be laid is generally determined by the speed of welding. This has resulted in substantial developments in pipeline welding techniques. Arc welding is still the dominant process used in practice, and forge welding processes have had limited successful application to date, in spite of large investments in process development. Power beam processes have also been investigated in detail and the latest laser systems now show promise for practical application. In recent years the use of high strength steels has substantially reduced the cost of pipeline installation, with X70 and X80 being commonly used. This use of high strength pipeline produced by thermomechanical processing has also been researched. They must all meet three requirments, high productivity, satisfactory weld properties, and weld quality

  16. Allowable Differential Settlement of Oil Pipelines

    Directory of Open Access Journals (Sweden)

    Zahra Faeli

    2010-10-01

    Full Text Available Abstract The allowable settlement of pipelines has been mentioned rarely in design references and codes. The present paper studies the effects of differential settlement of pipeline bed on resulted forces and deformations and then determines the allowable differential settlement of pipelines in two conditions as follows: (i heterogeneous soil bed and (ii adjacent to steel tanks. To accomplish the studies, numerical simulation of pipeline is used. The pipeline bed is idealized by Winkler springs and four-element standard viscoelastic Burger model. Also, the use of geosynthetic reinforcement is studied in heterogeneous soil beds and the effect of geosynthetics on decreasing the settlement is investigated. The pipeline-tank joints in two cases of fixed and flexible joints are investigated and the results for two kinds of joints are compared.

  17. Analysis of Fission Products on the AGR-1 Capsule Components

    Energy Technology Data Exchange (ETDEWEB)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston; Scott A. Ploger

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed to determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.

  18. Analysing intracellular deformation of polymer capsules using structured illumination microscopy

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Sun, Huanli; Müllner, Markus; Yan, Yan; Noi, Ka Fung; Ping, Yuan; Caruso, Frank

    2016-06-01

    Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces, which induce capsule deformation during cell uptake, vary between cell lines, indicating that the capsules are exposed to higher mechanical forces in HeLa cells, followed by RAW264.7 and then differentiated THP-1 cells. Our study demonstrates the use of super-resolution SIM in analysing intracellular capsule deformation, offering important insights into the cellular processing of drug carriers in cells and providing fundamental knowledge of intracellular mechanobiology. Furthermore, this study may aid in the design of novel drug carriers that are sensitive to deformation for enhanced drug release properties.Understanding the behaviour of therapeutic carriers is important in elucidating their mechanism of action and how they are processed inside cells. Herein we examine the intracellular deformation of layer-by-layer assembled polymer capsules using super-resolution structured illumination microscopy (SIM). Spherical- and cylindrical-shaped capsules were studied in three different cell lines, namely HeLa (human epithelial cell line), RAW264.7 (mouse macrophage cell line) and differentiated THP-1 (human monocyte-derived macrophage cell line). We observed that the deformation of capsules was dependent on cell line, but independent of capsule shape. This suggests that the mechanical forces

  19. 76 FR 28326 - Pipeline Safety: National Pipeline Mapping System Data Submissions and Submission Dates for Gas...

    Science.gov (United States)

    2011-05-17

    ... Systems and Liquefied Natural Gas Annual Reports AGENCY: Pipeline and Hazardous Materials Safety... operators of gas transmission and gathering systems and Liquefied Natural Gas (LNG) facilities that they... to Pipeline and Liquefied Natural Gas Reporting Requirements'' (One Rule). This rulemaking...

  20. Automatic Pipeline Surveillance Air-Vehicle

    OpenAIRE

    Alqaan, Hani

    2016-01-01

    This thesis presents the developments of a vision-based system for aerial pipeline Right-of-Way surveillance using optical/Infrared sensors mounted on Unmanned Aerial Vehicles (UAV). The aim of research is to develop a highly automated, on-board system for detecting and following the pipelines; while simultaneously detecting any third-party interference. The proposed approach of using a UAV platform could potentially reduce the cost of monitoring and surveying pipelines when...

  1. MUSE Pipeline: the First Year in Operation

    Science.gov (United States)

    Weilbacher, Peter

    2015-12-01

    I will present the MUSE pipeline, in terms of calibration data required, reduction steps performed, computing requirements needed. I will then highlight some unusual algorithms. I will describe changes that became necessary during commissioning and the first year of operations and how the pipeline is now integrated into operations on Paranal. I will conclude by showing some example results that were enabled by the MUSE instrument and the pipeline in the first year.

  2. MUSE Pipeline: the First Year in Operation

    OpenAIRE

    Weilbacher, Peter

    2015-01-01

    I will present the MUSE pipeline, in terms of calibration data required, reduction steps performed, computing requirements needed. I will then highlight some unusual algorithms. I will describe changes that became necessary during commissioning and the first year of operations and how the pipeline is now integrated into operations on Paranal. I will conclude by showing some example results that were enabled by the MUSE instrument and the pipeline in the first year.

  3. Preprint ARPPS Augmented Reality Pipeline Prospect System

    OpenAIRE

    Zhang, Xiaolei; Han, Yong; Hao, DongSheng; Lv, Zhihan

    2015-01-01

    This is the preprint version of our paper on ICONIP. Outdoor augmented reality geographic information system (ARGIS) is the hot application of augmented reality over recent years. This paper concludes the key solutions of ARGIS, designs the mobile augmented reality pipeline prospect system (ARPPS), and respectively realizes the machine vision based pipeline prospect system (MVBPPS) and the sensor based pipeline prospect system (SBPPS). With the MVBPPS's realization, this paper studies the neu...

  4. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  5. Transmission pipeline calculations and simulations manual

    CERN Document Server

    Menon, E Shashi

    2014-01-01

    Transmission Pipeline Calculations and Simulations Manual is a valuable time- and money-saving tool to quickly pinpoint the essential formulae, equations, and calculations needed for transmission pipeline routing and construction decisions. The manual's three-part treatment starts with gas and petroleum data tables, followed by self-contained chapters concerning applications. Case studies at the end of each chapter provide practical experience for problem solving. Topics in this book include pressure and temperature profile of natural gas pipelines, how to size pipelines for specified f

  6. A quick guide to pipeline engineering

    CERN Document Server

    Alkazraji, D

    2008-01-01

    Pipeline engineering requires an understanding of a wide range of topics. Operators must take into account numerous pipeline codes and standards, calculation approaches, and reference materials in order to make accurate and informed decisions.A Quick Guide to Pipeline Engineering provides concise, easy-to-use, and accessible information on onshore and offshore pipeline engineering. Topics covered include: design; construction; testing; operation and maintenance; and decommissioning.Basic principles are discussed and clear guidance on regulations is provided, in a way that will

  7. Tubular lining material for pipelines having bends

    Energy Technology Data Exchange (ETDEWEB)

    Moringa, A.; Sakaguchi, Y.; Hyodo, M.; Yagi, I.

    1987-03-24

    A tubular lining material for pipelines having bends or curved portions comprises a tubular textile jacket made of warps and wefts woven in a tubular form overlaid with a coating of a flexible synthetic resin. It is applicable onto the inner surface of a pipeline having bends or curved portions in such manner that the tubular lining material with a binder onto the inner surface thereof is inserted into the pipeline and allowed to advance within the pipeline, with or without the aid of a leading rope-like elongated element, while turning the tubular lining material inside out under fluid pressure. In this manner the tubular lining material is applied onto the inner surface of the pipeline with the binder being interposed between the pipeline and the tubular lining material. The lining material is characterized in that a part of all of the warps are comprised of an elastic yarn around which, over the full length thereof, a synthetic fiber yarn or yarns have been left-and/or right-handedly coiled. This tubular lining material is particularly suitable for lining a pipeline having an inner diameter of 25-200 mm and a plurality of bends, such as gas service pipelines or house pipelines, without occurrence of wrinkles in the lining material in a bend.

  8. RAMA Surveillance Capsule and Component Activation Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Kenneth E.; Jones, Eric N. [TransWare Enterprises Inc., 1565 Mediterranean Dr., Sycamore, IL 60178 (United States); Carter, Robert G. [Electric Power Research Institute, 1300 West W. T. Harris Blvd., Charlotte, NC 28262 (United States)

    2011-07-01

    This paper presents the calculated-to-measured ratios associated with the application of the RAMA Fluence Methodology software to light water reactor surveillance capsule and reactor component activation evaluations. Comparisons to measurements are performed for pressurized water reactor and boiling water reactor surveillance capsule activity specimens from seventeen operating light water reactors. Comparisons to measurements are also performed for samples removed from the core shroud, top guide, and jet pump brace pads from two reactors. In conclusion: The flexible geometry modeling capabilities provided by RAMA, combined with the detailed representation of operating reactor history and anisotropic scattering detail, produces accurate predictions of the fast neutron fluence and neutron activation for BWR and PWR surveillance capsule geometries. This allows best estimate RPV fluence to be determined without the need for multiplicative bias corrections. The three-dimensional modeling capability in RAMA provides an accurate estimate of the fast neutron fluence for regions far removed from the core mid-plane elevation. The comparisons to activation measurements for various core components indicate that the RAMA predictions are reasonable, and notably conservative (i.e., C/M ratios are consistently greater than unity). It should be noted that in the current evaluations, the top and bottom fuel regions are represented by six inch height nodes. As a result, the leakage-induced decrease in power near the upper and lower edges of the core are not well represented in the current models. More precise predictions of fluence for components that lie above and below the core boundaries could be obtained if the upper and lower fuel nodes were subdivided into multiple axial regions with assigned powers that reflect the neutron leakage at the top and bottom of the core. This use of additional axial sub-meshing at the top and bottom of the core is analogous to the use of pin

  9. 76 FR 44985 - Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding

    Science.gov (United States)

    2011-07-27

    ... Facilities Caused by Flooding AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT... pipeline facilities caused by severe flooding. This advisory includes actions that operators should consider taking to ensure the integrity of pipelines in case of flooding. ADDRESSES: This document can...

  10. A comparative study on liquid core formulation on the diameter on the alginate capsules

    Science.gov (United States)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  11. Vortex Rings from Sphagnum Moss Capsules

    CERN Document Server

    Chang, Emily S; Cha, Jung Ha; Strassman, Sam; Hard, Clara; Whitaker, Dwight L

    2010-01-01

    Long distance wind dispersal requires small spores with low terminal velocities, which can be held aloft by turbulent air currents until they are deposited in suitable habitats for colonization. The inherent difficulty in dispersing spores by wind is that spores easily carried by wind are also rapidly decelerated when moving through still air. Thus the height of spore release is critical in determining their range of dispersal. Vascular plants with wind dispersed spores use the height of the plant to lift spores into sufficient wind currents for dispersal, however non-vascular plants such as Sphagnum cannot grow sufficiently tall. These fluid dynamics videos show how exploding capsules of {\\em Sphagnum} moss generate vortex rings to carry spores to heights above 10 cm with an initial velocity of 16 m s$^{-1}$. In contrast spores launched ballistically at these speeds through still air would travel only 2-7 mm.

  12. Optimal Bowel Preparation for Video Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Hyun Joo Song

    2016-01-01

    Full Text Available During video capsule endoscopy (VCE, several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG- based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE.

  13. 76 FR 65778 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2011-10-24

    ..., PHMSA published a notice with request for comments in the Federal Register (76 FR 45904). The notice... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  14. 77 FR 15453 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2012-03-15

    ..., PHMSA published a notice with request for comments in the Federal Register (76 FR 81013). The notice... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  15. 75 FR 4610 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2010-01-28

    ... Hazardous Materials Safety Administration (PHMSA) published a notice in the Federal Register (74 FR 61403... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration. ACTION: Notice and request for...

  16. 78 FR 55775 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2013-09-11

    ... 23, 2013, (78 FR 23972). PHMSA received one comment in response to that notice. PHMSA is publishing... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  17. 75 FR 32836 - Pipeline Safety: Workshop on Public Awareness Programs

    Science.gov (United States)

    2010-06-09

    ... Institute Interstate Natural Gas Association of America (8) Question & Answer Period. (9) Lessons Learned... challenges faced by the pipeline industry). Hazardous Liquid Gas Transmission/Gathering Natural Gas... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Workshop on Public...

  18. Addressing the workforce pipeline challenge

    International Nuclear Information System (INIS)

    A secure and affordable energy supply is essential for achieving U.S. national security, in continuing U.S. prosperity and in laying the foundations to enable future economic growth. To meet this goal the next generation energy workforce in the U.S., in particular those needed to support instrumentation, controls and advanced operations and maintenance, is a critical element. The workforce is aging and a new workforce pipeline, to support both current generation and new build has yet to be established. The paper reviews the challenges and some actions being taken to address this need. (authors)

  19. Addressing the workforce pipeline challenge

    Energy Technology Data Exchange (ETDEWEB)

    Leonard Bond; Kevin Kostelnik; Richard Holman

    2006-11-01

    A secure and affordable energy supply is essential for achieving U.S. national security, in continuing U.S. prosperity and in laying the foundations to enable future economic growth. To meet this goal the next generation energy workforce in the U.S., in particular those needed to support instrumentation, controls and advanced operations and maintenance, is a critical element. The workforce is aging and a new workforce pipeline, to support both current generation and new build has yet to be established. The paper reviews the challenges and some actions being taken to address this need.

  20. Review of Oil and Gas Pipeline Construction in 2007

    Institute of Scientific and Technical Information of China (English)

    Qu Hong

    2008-01-01

    @@ China's pipeline industry has developed for 50 years till 2008. In the past 10 years, more than 50,000 kilometers of long-distance oil and gas pipelines have been constructed,of which gas pipelines reached about 30,000 kilometers,crude oil pipelines about 17,000 kilometers, and product oil pipelines about 7,000 kilometers. Oil and gas pipeline networks across regions have taken shape.

  1. Dynamic pressure measures for long pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Likun Wang; Hongchao Wang; Min Xiong; Bin Xu; Dongjie Tan; Hengzhang Zhou [PetroChina Pipeline Company, Langfang (China). R and D Center

    2009-07-01

    Pipeline leak detection method based on dynamic pressure is studied. The feature of dynamic pressure which is generated by the leakage of pipeline is analyzed. The dynamic pressure method is compared with the static pressure method for the advantages and disadvantages in pipeline leak detection. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure. Field tests show that the dynamic pressure method detects pipeline leak rapidly and precisely. (author)

  2. Adhesion and detachment of a capsule in axisymmetric flow

    Science.gov (United States)

    Keh, M. P.; Leal, L. G.

    2016-05-01

    The adhesion and detachment of a capsule on a solid boundary surface is studied via a combination of scaling theory and numerical simulation and the behavior is compared and contrasted with a vesicle. It is shown that the dominant physical property for both capsules and vesicles is the area dilation modulus Ks of the membrane. The nonzero shear modulus Gs for capsules increases the resistance to deformation and thus decreases slightly the equilibrium contact radius for an adhered capsule compared to an adhered vesicle. The detachment process in this study is due to an external axisymmetric flow. Unlike a rigid body that must be pulled away without change of shape, capsules (and vesicles) almost always detach dominantly by peeling in which the contact radius decreases but the minimum separation distance does not change until the final moments of detachment. Compared to a vesicle with the same Ks, a capsule maintains a more compact shape and is harder to elongate under a given external flow. Hence, the detachment process is slower for capsules compared to vesicles with the same Ks.

  3. In vitro study on sustained release capsule formulation of acetazolamide.

    Science.gov (United States)

    Pandey, V P; Kannan, K; Manavalan, R; Desai, N

    2003-10-01

    In the present study formulation of sustained release capsule of acetazolamide 250 mg was tried using nonpareil seeds. Nonpareil seeds were coated with drug, polyvinylpyrrolidone, glyceryl monostearate, microcrystalline wax, and glyceryl distearate either individually or in combination to achieve sustained release capsule 250 mg. In successful formulation 20% drug coated pellets and 80% wax coated pellets were taken. Wax coated pellets for successful formulation contained coating of microcrystalline wax and glyceryl distearate on drug coated pellets of the same concentration of 1.6% w/w. Successful formulated sustained release capsule 250 mg of acetazolamide was compared in in vitro study with theoretical sustained release formulation suggested by wagner and one marketed sustained release capsule 250 mg. Formulated capsule showed result superior to or on par with marketed capsule. For successful formulation pellets were filled in '1' size hard gelatin capsule and stability study was carried out in hot air over at room temperature and 45 degrees C for 5 weeks. The formulation was found stable in respect of drug content and release rate.

  4. Patency(C) and agile(C) capsules

    Institute of Scientific and Technical Information of China (English)

    àngel Caunedo-àlvarez; Javier Romero-Vazquez; Juan M Herrerias-Gutierrez

    2008-01-01

    Small bowel strictures can be missed by current diagnostic methods.The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract,in a non-invasive manner.The available clinical trials have demonstrated that the Patency(C) capsule is a good tool for assessment of the functional patency of the small bowel,and it allows identification of those patients who can safely undergo a capsule endoscopy,despite clinical and radiographic evidence of small-bowel obstruction.Some cases of intestinal occlusion have been reported with the Patency(C) capsule,four of them needed surgery.So,a new capsule with two timer plugs (Agile(C) capsule) has been recently developed in order to minimize the risk of occlusion.This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture.

  5. Offshore Pipeline Locations in the Gulf of Mexico, Geographic NAD27, MMS (2007) [pipelines_points_mms_2007

    Data.gov (United States)

    Louisiana Geographic Information Center — Offshore Minerals Management Pipeline Locations for the Gulf of Mexico (GOM). Contains the points of the pipeline in the GOM. All pipelines existing in the...

  6. Offshore Pipeline Locations in the Gulf of Mexico, Geographic NAD27, MMS (2007) [pipelines_vectors_mms_2007

    Data.gov (United States)

    Louisiana Geographic Information Center — Offshore Minerals Management Pipeline Locations for the Gulf of Mexico (GOM). Contains the lines of the pipeline in the GOM. All pipelines existing in the databases...

  7. China Pins Hopes on Pipeline with Russia

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ China still has faith in the gigantic Sino-Russia oil pipeline, despite reports which said that Russia is inclined to build a competing pipeline in favor of Japan. CNPC, the company representing China to negotiate with Russia on the project, is reported to continue its preparation work to receive Russian crude.

  8. Battle over proposed Keystone pipeline continues

    Science.gov (United States)

    Showstack, Randy

    2013-07-01

    Opposing sides in the battle over the proposed construction of the controversial Keystone XL pipeline continue to push their messages on the issue. The American Petroleum Institute (API) announced on 9 July that it has launched a new advertising campaign in support of the pipeline, which, if built, will ship oil from Canadian tar sands to refineries in the Gulf of Mexico.

  9. PETROCHINA WEST EAST GAS PIPELINE & SALES COMPANY

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ PetroChina West East Gas Pipeline & Sales Company, a regional company directly under PetroChina Company Limited (PetroChina), is responsible for the construction and operation of the West-East Gas Pipeline Project, and the gas marketing and sales of the natural gas market in China.

  10. The LOFAR Known Pulsar Data Pipeline

    NARCIS (Netherlands)

    A. Alexov; J.W.T. Hessels; J.D. Mol; B. Stappers; J. van Leeuwen

    2010-01-01

    Abstract: Transient radio phenomena and pulsars are one of six LOFAR Key Science Projects (KSPs). As part of the Transients KSP, the Pulsar Working Group (PWG) has been developing the LOFAR Pulsar Data Pipelines to both study known pulsars as well as search for new ones. The pipelines are being deve

  11. China's First Digital Pipeline Moves Forward Completely

    Institute of Scientific and Technical Information of China (English)

    Li Zhanbin

    2005-01-01

    @@ The construction of China's first digital natural gas pipeline-Jining Branch of the West-East Gas Pipelinehas been accelerated completely. Up to May 8, the accumulative welded length of whole line exceeded 612 km, more than two thirds of the total length of the trunk pipeline of Jining Branch.

  12. Pipeline Protection Has Its Own Law

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    @@ The Law of the People's Republic of China on the Protection of Oil and Natural Gas Pipelines (hereinafter called "the Law") will be implemented officially on October 1 this year.This is the first time that oil and natural gas pipelines were protected and managed on legal basis.

  13. The School-to-Prison Pipeline

    Science.gov (United States)

    Elias, Marilyn

    2013-01-01

    Policies that encourage police presence at schools, harsh tactics including physical restraint, and automatic punishments that result in suspensions and out-of-class time are huge contributors to the school-to-prison pipeline, but the problem is more complex than that. The school-to-prison pipeline starts (or is best avoided) in the classroom.…

  14. NCBI prokaryotic genome annotation pipeline.

    Science.gov (United States)

    Tatusova, Tatiana; DiCuccio, Michael; Badretdin, Azat; Chetvernin, Vyacheslav; Nawrocki, Eric P; Zaslavsky, Leonid; Lomsadze, Alexandre; Pruitt, Kim D; Borodovsky, Mark; Ostell, James

    2016-08-19

    Recent technological advances have opened unprecedented opportunities for large-scale sequencing and analysis of populations of pathogenic species in disease outbreaks, as well as for large-scale diversity studies aimed at expanding our knowledge across the whole domain of prokaryotes. To meet the challenge of timely interpretation of structure, function and meaning of this vast genetic information, a comprehensive approach to automatic genome annotation is critically needed. In collaboration with Georgia Tech, NCBI has developed a new approach to genome annotation that combines alignment based methods with methods of predicting protein-coding and RNA genes and other functional elements directly from sequence. A new gene finding tool, GeneMarkS+, uses the combined evidence of protein and RNA placement by homology as an initial map of annotation to generate and modify ab initio gene predictions across the whole genome. Thus, the new NCBI's Prokaryotic Genome Annotation Pipeline (PGAP) relies more on sequence similarity when confident comparative data are available, while it relies more on statistical predictions in the absence of external evidence. The pipeline provides a framework for generation and analysis of annotation on the full breadth of prokaryotic taxonomy. For additional information on PGAP see https://www.ncbi.nlm.nih.gov/genome/annotation_prok/ and the NCBI Handbook, https://www.ncbi.nlm.nih.gov/books/NBK174280/. PMID:27342282

  15. Steam pipelines' effort and durability

    Directory of Open Access Journals (Sweden)

    J. Okrajni

    2007-06-01

    Full Text Available Purpose: The main problem addressed in the paper is the description of an effort and durability of steam pipelines under the conditions of mechanical and thermal interactions.Design/methodology/approach: The FEM modelling has been used to determine the stress and strain fields in the pipelines and to describe their behaviour under mechanical and thermal loading.Findings: An appropriate model description has been developed. So far, experimental verification of the usefulness of the model description to determine the stress and strain patterns in particular object and for chosen operation conditions has been made. The analysis made has shown that the most probable cause of cracks occurrence on the analyzed chosen pipeline’ inner surfaces are thermal deformations and constraints of their dislocations.Research limitations/implications: The developed description should be useful in problems of behaviour predictions of high temperature components and their durability assessment under different mechanical and thermal loadings in industry practical applications.Originality/value: The method, which more precise description of power industry components behaviour makes possible have been shown in the work. The work is addressed to researchers interested in problems of component behaviour prediction under different loadings that we can meet in the operation practice and to power industry engineering maintenance staff.

  16. Precise location of nonmetallic pipelines

    International Nuclear Information System (INIS)

    A method is described to conduct precise surveys of nonmetallic pipelines. After a thin stranded wire is pulled through a part of the pipe first an inductive or capacitative prelocation is made, in which especially curves are marked. After that with this wire a go-devil with a 500 mCi 60Co-radiation source is moved slowly from reference point to reference point. On the ground plane the corresponding maximum of the radiation intensity is detected and marked as the position of the pipe. About the experiences of the location of two local gas pipelines with 4987 and 11897 km length is reported. The average length of the located sections was about 300 m, the average distance between two reference points was a little more than 8 m. In the case of curves the distances were reduced to 0.5 - 1.0 m. The output of location was 16 h/km, the daily output ca. 600 m. The accuracy is better than +- 10 cm, while in the case of the inductive prelocation deviations of more than 50 cm could be found. During the locations the delivery of gas was uninterrupted. It can be carried out also in thickly populated regions without any danger by radioactive radiation. (Author)

  17. NCBI prokaryotic genome annotation pipeline.

    Science.gov (United States)

    Tatusova, Tatiana; DiCuccio, Michael; Badretdin, Azat; Chetvernin, Vyacheslav; Nawrocki, Eric P; Zaslavsky, Leonid; Lomsadze, Alexandre; Pruitt, Kim D; Borodovsky, Mark; Ostell, James

    2016-08-19

    Recent technological advances have opened unprecedented opportunities for large-scale sequencing and analysis of populations of pathogenic species in disease outbreaks, as well as for large-scale diversity studies aimed at expanding our knowledge across the whole domain of prokaryotes. To meet the challenge of timely interpretation of structure, function and meaning of this vast genetic information, a comprehensive approach to automatic genome annotation is critically needed. In collaboration with Georgia Tech, NCBI has developed a new approach to genome annotation that combines alignment based methods with methods of predicting protein-coding and RNA genes and other functional elements directly from sequence. A new gene finding tool, GeneMarkS+, uses the combined evidence of protein and RNA placement by homology as an initial map of annotation to generate and modify ab initio gene predictions across the whole genome. Thus, the new NCBI's Prokaryotic Genome Annotation Pipeline (PGAP) relies more on sequence similarity when confident comparative data are available, while it relies more on statistical predictions in the absence of external evidence. The pipeline provides a framework for generation and analysis of annotation on the full breadth of prokaryotic taxonomy. For additional information on PGAP see https://www.ncbi.nlm.nih.gov/genome/annotation_prok/ and the NCBI Handbook, https://www.ncbi.nlm.nih.gov/books/NBK174280/.

  18. Software for pipeline integrity administration

    Energy Technology Data Exchange (ETDEWEB)

    Soula, Gerardo; Perona, Lucas Fernandez [Gie SA., Buenos Aires (Argentina); Martinich, Carlos [Refinaria do Norte S. A. (REFINOR), Tartagal, Provincia de Salta (Argentina)

    2009-07-01

    A Software for 'pipeline integrity management' was developed. It allows to deal with Geographical Information and a PODS database (Pipeline Open database Standard) simultaneously, in a simple and reliable way. The premises for the design were the following: didactic, geo referenced, multiple reference systems. Program skills: 1.PODS+GIS: the PODS database in which the software is based on is completely integrated with the GIS module. 2 Management of different kinds of information: it allows to manage information on facilities, repairs, interventions, physical inspections, geographical characteristics, compliance with regulations, training, offline events, operation measures, O and M information treatment and importing specific data and studies in a massive way. It also assures the integrity of the loaded information. 3 Right of way survey: it allows to verify the class location, ROW occupation, sensitive areas identification and to manage landowners. 4 Risk analysis: it is done in a qualitative way, depending on the entered data, allowing the user to identify the riskiest stretches of the system. Either results from risk analysis, data and consultations made about the database, can be exported to standard formats. (author)

  19. Electrical fingerprint of pipeline defects

    Energy Technology Data Exchange (ETDEWEB)

    Mica, Isabella [STMicroelectronics Srl, via C.Olivetti 2, 20041 Agrate Brianza (Italy)]. E-mail: isabella.mica@st.com; Polignano, Maria Luisa [STMicroelectronics Srl, via C.Olivetti 2, 20041 Agrate Brianza (Italy); Marco, Cinzia De [STMicroelectronics Srl, via C.Olivetti 2, 20041 Agrate Brianza (Italy)

    2004-12-15

    Pipeline defects are dislocations that connect the source region of the transistor with the drain region. They were widely reported to occur in CMOS, BiCMOS devices and recently in SOI technologies. They can reduce device yield either by affecting the devices functionality or by increasing the current consumption under stand-by conditions. In this work the electrical fingerprint of these dislocations is studied, its purpose is to enable us to identify these defects as the ones responsible for device failure. It is shown that the pipeline defects are responsible for a leakage current from source to drain in the transistors. This leakage has a resistive characteristic and it is lightly modulated by the body bias. It is not sensitive to temperature; vice versa the off-current of a good transistor exhibits the well-known exponential dependence on 1/T. The emission spectrum of these defects was studied and compared with the spectrum of a good transistor. The paper aims to show that the spectrum of a defective transistor is quite peculiar; it shows well defined peaks, whereas the spectrum of a good transistor under saturation conditions is characterized by a broad spectral light emission distribution. Finally the deep-level transient spectroscopy (DLTS) is tried on defective diodes.

  20. Efficiency improvements in pipeline transportation systems

    Energy Technology Data Exchange (ETDEWEB)

    Banks, W. F.; Horton, J. F.

    1977-09-09

    This report identifies potential energy-conservative pipeline innovations that are most energy- and cost-effective and formulates recommendations for the R, D, and D programs needed to exploit those opportunities. From a candidate field of over twenty classes of efficiency improvements, eight systems are recommended for pursuit. Most of these possess two highly important attributes: large potential energy savings and broad applicability outside the pipeline industry. The R, D, and D program for each improvement and the recommended immediate next step are described. The eight technologies recommended for R, D, and D are gas-fired combined cycle compressor station; internally cooled internal combustion engine; methanol-coal slurry pipeline; methanol-coal slurry-fired and coal-fired engines; indirect-fired coal-burning combined-cycle pump station; fuel-cell pump station; drag-reducing additives in liquid pipelines; and internal coatings in pipelines.

  1. Commissioning of a new helium pipeline

    Science.gov (United States)

    2000-01-01

    Jerry Jorgensen welcomes the audience to the commissioning of a new high-pressure helium pipeline at Kennedy Space Center. Jorgensen, with Space Gateway Support (SGS), is the pipeline project manager. To the right is Ramon Lugo, acting executive director, JPMO. Others at the ceremony were Center Director Roy Bridges; Col. Samuel Dick, representative of the 45th Space Wing; David Herst, director, Delta IV Launch Sites; Pierre Dufour, president and CEO, Air Liquide America Corporation; and Michael Butchko, president, SGS. The pipeline will service launch needs at the new Delta IV Complex 37 at Cape Canaveral Air Force Station. The nine-mile-long buried pipeline will also serve as a backup helium resource for Shuttle launches. Nearly one launch's worth of helium will be available in the pipeline to support a Shuttle pad in an emergency. The line originates at the Helium Facility on KSC and terminates in a meter station at the perimeter of the Delta IV launch pad.

  2. optimization for trenchless reconstruction of pipelines

    Directory of Open Access Journals (Sweden)

    Zhmakov Gennadiy Nikolaevich

    2015-01-01

    Full Text Available Today the technologies of trenchless reconstruction of pipelines are becoming and more widely used in Russia and abroad. One of the most perspective is methods is shock-free destruction of the old pipeline being replaced with the help of hydraulic installations with working mechanism representing a cutting unit with knife disks and a conic expander. A construction of a working mechanism, which allows making trenchless reconstruction of pipelines of different diameters, is optimized and patented and its developmental prototype is manufactured. The dependence of pipeline cutting force from knifes obtusion of the working mechanisms. The cutting force of old steel pipelines with obtuse knife increases proportional to the value of its obtusion. Two stands for endurance tests of the knifes in laboratory environment are offered and patented.

  3. Technical progress in pipeline design and construction

    Energy Technology Data Exchange (ETDEWEB)

    Hausken, K.B.

    1995-12-31

    This paper considers the technical progress in offshore pipeline construction with limitation to some general subjects covering pipeline design, installation and start-up. In future the use of limit state pipeline design philosophy, may be implemented as an alternative to the stress based design commonly used to day giving a potential for further optimisation of the pipeline design and consequently reduction of the initial investment. Comprehensive research and development efforts in Norway in the second half of the 1970`s, made it technically feasible to cross the deep water Norwegian Trench in the 1980`s. In addition, the development of several offshore pipeline systems until to day including gas distribution systems to the European continent, have brought Norway to the forefront of technical expertise

  4. Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.

    Science.gov (United States)

    Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi

    2014-08-01

    Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.

  5. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule. PMID:27254279

  6. Nanoparticle-Stabilized Capsules for the Treatment of Bacterial Biofilms.

    Science.gov (United States)

    Duncan, Bradley; Li, Xiaoning; Landis, Ryan F; Kim, Sung Tae; Gupta, Akash; Wang, Li-Sheng; Ramanathan, Rajesh; Tang, Rui; Boerth, Jeffrey A; Rotello, Vincent M

    2015-08-25

    Bacterial biofilms are widely associated with persistent infections. High resistance to conventional antibiotics and prevalent virulence makes eliminating these bacterial communities challenging therapeutic targets. We describe here the fabrication of a nanoparticle-stabilized capsule with a multicomponent core for the treatment of biofilms. The peppermint oil and cinnamaldehyde combination that comprises the core of the capsules act as potent antimicrobial agents. An in situ reaction at the oil/water interface between the nanoparticles and cinnamaldehyde structurally augments the capsules to efficiently deliver the essential oil payloads, effectively eradicating biofilms of clinically isolated pathogenic bacteria strains. In contrast to their antimicrobial action, the capsules selectively promoted fibroblast proliferation in a mixed bacteria/mammalian cell system making them promising for wound healing applications. PMID:26083534

  7. Wireless capsule video endoscopy:Three years of experience

    Institute of Scientific and Technical Information of China (English)

    Rami Eliakim

    2004-01-01

    AIM: To review and summerize the current literatue regarding M2A wireless capsule endoscopy.METHODS: Peer reviewed publications regarding the use of capsule endoscopy as well as our personal experience were reviewed.RESULTS: Review of the literature dearly showed that capsule endoscopy was superior to enteroscopy, small bowel follow through and computerized tomography in patients with obscure gastrointestinal bleeding, iron deficiency anemia,or suspected Crohn′s disease. It was very sensitive for the diagnosis of small bowel tumors and for survailance of small bowel pathology in patients with Gardner syndrome or familial adenomatous polyposis syndrome. Its role in celiac disease and in patients with known Crohn′s disease was currently being investigated.CONCLUSION: Capsule video endoscopy is a superior and more sensitive diagnostic tool than barium follow through,enteroscopy and entero- CT in establishing the diagnosis of many small bowel pathologies.

  8. Diamagnetically-stabilized levitation control of an intraluminal magnetic capsule.

    Science.gov (United States)

    Lam, Michael; Mintchev, Martin P

    2008-01-01

    Controlled navigation promotes full utilization of capsule endoscopy for reliable real-time diagnosis in the gastrointestinal (GI) tract, but intermittent natural peristalsis can disturb the navigational control, destabilize the capsule and take it out of levitation. A real-size magnetic navigation system that can handle peristaltic forces of up to 1.5 N was designed utilizing the computer-aided design (CAD) system Maxwell 3D (Ansoft, Pittsburg, PA), and was verified using a small-size physical experimental setup. The proposed system contains a pair of 50-cm in diameter, 10,000-turns copper electromagnets with a 10-cm by 10-cm ferrous core driven by currents of up to 300 Amperes and can successfully maintain position control over the levitating capsule during peristalsis. The addition of Bismuth diamagnetic casing for stabilizing the levitating capsule was also studied. PMID:19163990

  9. Capsule endoscopy of the future: What's on the horizon?

    Science.gov (United States)

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-10-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years.

  10. 21 CFR 520.1803 - Piperazine citrate capsules.

    Science.gov (United States)

    2010-04-01

    .... (c) Conditions of use. (1) It is used in dogs and cats for the removal of large roundworms (Toxocara canis and Toxascaris leonina). (2) The contents of 1 capsule should be mixed with the food of the...

  11. Perforation forces of the intact porcine anterior lens capsule.

    Science.gov (United States)

    Ullrich, Franziska; Lussi, Jonas; Felekis, Dimitrios; Michels, Stephan; Petruska, Andrew J; Nelson, Bradley J

    2016-09-01

    During the first step of cataract surgery, the lens capsule is perforated and a circular hole is created with a sharp instrument, a procedure called capsulorhexis. To develop automated systems that can assist ophthalmologists during capsulorhexis, the forces required must be quantified. This study investigates perforation forces of the central anterior lens capsule in porcine eyes, which are used as a conservative model for the human eye. A micro-mechanical characterisation method is presented that measures capsular bag perforation forces with a high precision positioning and high-resolution force sensing system. The force during perforation of the anterior lens capsule was measured with various sized needles and indentation speeds and is found to be 15-35mN. A bio-mechanical model is identified that describes an exponential correlation between indentation force and depth, indicating strain hardening behaviour of the porcine anterior lens capsule.

  12. Pipeline Decommissioning Trial AWE Berkshire UK - 13619

    Energy Technology Data Exchange (ETDEWEB)

    Agnew, Kieran [AWE, Aldermaston, Reading, RG7 4PR (United Kingdom)

    2013-07-01

    This Paper details the implementation of a 'Decommissioning Trial' to assess the feasibility of decommissioning the redundant pipeline operated by AWE located in Berkshire UK. The paper also presents the tool box of decommissioning techniques that were developed during the decommissioning trial. Constructed in the 1950's and operated until 2005, AWE used a pipeline for the authorised discharge of treated effluent. Now redundant, the pipeline is under a care and surveillance regime awaiting decommissioning. The pipeline is some 18.5 km in length and extends from AWE site to the River Thames. Along its route the pipeline passes along and under several major roads, railway lines and rivers as well as travelling through woodland, agricultural land and residential areas. Currently under care and surveillance AWE is considering a number of options for decommissioning the pipeline. One option is to remove the pipeline. In order to assist option evaluation and assess the feasibility of removing the pipeline a decommissioning trial was undertaken and sections of the pipeline were removed within the AWE site. The objectives of the decommissioning trial were to: - Demonstrate to stakeholders that the pipeline can be removed safely, securely and cleanly - Develop a 'tool box' of methods that could be deployed to remove the pipeline - Replicate the conditions and environments encountered along the route of the pipeline The onsite trial was also designed to replicate the physical prevailing conditions and constraints encountered along the remainder of its route i.e. working along a narrow corridor, working in close proximity to roads, working in proximity to above ground and underground services (e.g. Gas, Water, Electricity). By undertaking the decommissioning trial AWE have successfully demonstrated the pipeline can be decommissioned in a safe, secure and clean manor and have developed a tool box of decommissioning techniques. The tool box of includes

  13. Pipeline Decommissioning Trial AWE Berkshire UK - 13619

    International Nuclear Information System (INIS)

    This Paper details the implementation of a 'Decommissioning Trial' to assess the feasibility of decommissioning the redundant pipeline operated by AWE located in Berkshire UK. The paper also presents the tool box of decommissioning techniques that were developed during the decommissioning trial. Constructed in the 1950's and operated until 2005, AWE used a pipeline for the authorised discharge of treated effluent. Now redundant, the pipeline is under a care and surveillance regime awaiting decommissioning. The pipeline is some 18.5 km in length and extends from AWE site to the River Thames. Along its route the pipeline passes along and under several major roads, railway lines and rivers as well as travelling through woodland, agricultural land and residential areas. Currently under care and surveillance AWE is considering a number of options for decommissioning the pipeline. One option is to remove the pipeline. In order to assist option evaluation and assess the feasibility of removing the pipeline a decommissioning trial was undertaken and sections of the pipeline were removed within the AWE site. The objectives of the decommissioning trial were to: - Demonstrate to stakeholders that the pipeline can be removed safely, securely and cleanly - Develop a 'tool box' of methods that could be deployed to remove the pipeline - Replicate the conditions and environments encountered along the route of the pipeline The onsite trial was also designed to replicate the physical prevailing conditions and constraints encountered along the remainder of its route i.e. working along a narrow corridor, working in close proximity to roads, working in proximity to above ground and underground services (e.g. Gas, Water, Electricity). By undertaking the decommissioning trial AWE have successfully demonstrated the pipeline can be decommissioned in a safe, secure and clean manor and have developed a tool box of decommissioning techniques. The tool box of includes; - Hot tapping - a method

  14. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  15. The APOGEE Data Reduction pipeline

    Science.gov (United States)

    Holtzman, Jon A.; Nidever, D. L.; Nguyen, D.; Shetrone, M. D.; Majewski, S.; Schiavon, R. P.

    2014-01-01

    The SDSS-III APOGEE survey is obtaining hundreds of thousands of individual high resolution near-IR spectra of Milky Way stars. Data are accumulated in data cubes, with individual non-destructive readouts occuring every 10 seconds, across three separate HgCdTe detectors. Exposures are obtained in pairs, with the detector array dithered by 0.5 pixel between exposures in the pair, to ensure well-sampled final images. Multiple pairs are taken in a given visit to a field, and multiple visits are made to each field. The spectra have significant contributions from night sky emission and telluric absorption. We describe the APOGEE data reduction pipeline that takes the multiple visits of multiple pairs of data cubes and reduces them, including measurements of radial velocities for each visit, to final, calibrated, combined spectra. _

  16. Bushen Yisui Capsule ameliorates axonal injury in experimental autoimmune encephalomyelitis

    Institute of Scientific and Technical Information of China (English)

    Ling Fang; Lei Wang; Qi Zheng; Tao Yang; Hui Zhao; Qiuxia Zhang; Kangning Li; Li Zhou; Haiyang Gong; Yongping Fan

    2013-01-01

    A preliminary clinical study by our group demonstrated Bushen Yisui Capsule (formerly cal ed Er-huang Formula) in combination with conventional therapy is an effective prescription for the treat-ment of multiple sclerosis. However, its effect on axonal injury during early multiple sclerosis re-mains unclear. In this study, a MOG 35-55-immunized C57BL/6 mouse model of experimental au-toimmune encephalomyelitis was intragastrical y administered Bushen Yisui Capsule. The results showed that Bushen Yisui Capsule effectively improved clinical symptoms and neurological function of experimental autoimmune encephalomyelitis. In addition, amyloid precursor protein expression was down-regulated and microtubule-associated protein 2 was up-regulated. Experimental findings indicate that the disease-preventive mechanism of Bushen Yisui Capsule in experimental autoim-mune encephalomyelitis was mediated by amelioration of axonal damage and promotion of rege-neration. But the effects of the high-dose Bushen Yisui Capsule group was not better than that of the medium-dose and low-dose Bushen Yisui Capsule group in preventing neurological dysfunction.

  17. Pickering Emulsion-Based Marbles for Cellular Capsules

    Directory of Open Access Journals (Sweden)

    Guangzhao Zhang

    2016-07-01

    Full Text Available The biodegradable cellular capsule, being prepared from simple vaporization of liquid marbles, is an ideal vehicle for the potential application of drug encapsulation and release. This paper reports the fabrication of cellular capsules via facile vaporization of Pickering emulsion marbles in an ambient atmosphere. Stable Pickering emulsion (water in oil was prepared while utilizing dichloromethane (containing poly(l-lactic acid and partially hydrophobic silica particles as oil phase and stabilizing agents respectively. Then, the Pickering emulsion marbles were formed by dropping emulsion into a petri dish containing silica particles with a syringe followed by rolling. The cellular capsules were finally obtained after the complete vaporization of both oil and water phases. The technique of scanning electron microscope (SEM was employed to research the microstructure and surface morphology of the prepared capsules and the results showed the cellular structure as expected. An in vitro drug release test was implemented which showed a sustained release property of the prepared cellular capsules. In addition, the use of biodegradable poly(l-lactic acid and the biocompatible silica particles also made the fabricated cellular capsules of great potential in the application of sustained drug release.

  18. Electromagnetic wave propagation of wireless capsule endoscopy in human body

    Institute of Scientific and Technical Information of China (English)

    LIM; Eng-Gee; 王炤; 陈瑾慧; TILLO; Tammam; MAN; Ka-lok

    2013-01-01

    Wireless capsule endoscopy(WCE) is a promising technique which has overcome some limitations of traditional diagnosing tools, such as the comfortlessness of the cables and the inability of examining small intestine section. However, this technique is still far from mature and asks for the feasible improvements. For example, the relatively low transmission data rate and the absence of the real-time localization information of the capsule are all important issues. The studies of them rely on the understanding of the electromagnetic wave propagation in human body. Investigation of performance of WCE communication system was carried out by studying electromagnetic(EM) wave propagation of the wireless capsule endoscopy transmission channel. Starting with a pair of antennas working in a human body mimic environment, the signal transmissions and attenuations were examined. The relationship between the signal attenuation and the capsule(transmitter) position, and direction was also evaluated. These results provide important information for real-time localization of the capsule. Moreover, the pair of antennas and the human body were treated as a transmission channel, on which the binary amplitude shift keying(BASK) modulation scheme was used. The relationship between the modulation scheme, data rate and bit error rate was also determined in the case of BASK. With the obtained studies, it make possible to provide valuable information for further studies on the selection of the modulation scheme and the real-time localization of the capsules.

  19. Simulating Space Capsule Water Landing with Explicit Finite Element Method

    Science.gov (United States)

    Wang, John T.; Lyle, Karen H.

    2007-01-01

    A study of using an explicit nonlinear dynamic finite element code for simulating the water landing of a space capsule was performed. The finite element model contains Lagrangian shell elements for the space capsule and Eulerian solid elements for the water and air. An Arbitrary Lagrangian Eulerian (ALE) solver and a penalty coupling method were used for predicting the fluid and structure interaction forces. The space capsule was first assumed to be rigid, so the numerical results could be correlated with closed form solutions. The water and air meshes were continuously refined until the solution was converged. The converged maximum deceleration predicted is bounded by the classical von Karman and Wagner solutions and is considered to be an adequate solution. The refined water and air meshes were then used in the models for simulating the water landing of a capsule model that has a flexible bottom. For small pitch angle cases, the maximum deceleration from the flexible capsule model was found to be significantly greater than the maximum deceleration obtained from the corresponding rigid model. For large pitch angle cases, the difference between the maximum deceleration of the flexible model and that of its corresponding rigid model is smaller. Test data of Apollo space capsules with a flexible heat shield qualitatively support the findings presented in this paper.

  20. Internal capsule stroke in the common marmoset.

    Science.gov (United States)

    Puentes, S; Kaido, T; Hanakawa, T; Ichinohe, N; Otsuki, T; Seki, K

    2015-01-22

    White matter (WM) impairment and motor deficit after stroke are directly related. However, WM injury mechanisms and their relation to motor disturbances are still poorly understood. In humans, the anterior choroidal artery (AChA) irrigates the internal capsule (IC), and stroke to this region can induce isolated motor impairment. The goal of this study was to analyze whether AChA occlusion can injure the IC in the marmoset monkey. The vascular distribution of the marmoset brain was examined by colored latex perfusion and revealed high resemblance to the human brain anatomy. Next, a new approach to electrocoagulate the AChA was developed and chronic experiments showed infarction compromising the IC on magnetic resonance imaging (MRI) scanning (day 4) and histology (day 11). Behavioral analysis was performed using a neurologic score previously developed and our own scoring method. Marmosets showed a decreased score that was still evident at day 10 after AChA electrocoagulation. We developed a new approach able to induce damage to the marmoset IC that may be useful for the detailed study of WM impairment and behavioral changes after stroke in the nonhuman primate. PMID:25453768

  1. [Clinical practice using colon capsule endoscopy].

    Science.gov (United States)

    Kakugawa, Yasuo; Matsumoto, Minori; Saito, Yutaka

    2014-01-01

    PillCam COLON capsule endoscopy(CCE) (Given Imaging Ltd., Yoqneam, Israel) is one of the most recent diagnostic technologies designed to explore the colorectum. The first generation of CCE was released onto the market in 2006, and the second generation (PillCam COLON 2 : CCE-2), with increased sensitivity, was released in 2009. The CCE-2 has 2 imagers with a much wider angle of view that has been increased to 172 degrees per imager, allowing nearly 360 degrees coverage of the colon by two. The most unique feature of the CCE-2 is its adaptive frame rate (AFR). This new technology allows the CCE-2 to capture 35 images per second when in motion and 4 images per second when virtually stationary. The per-patient CCE-2 sensitivity for detecting polyps > or = 6 mm has been reported as 84%-91%. These recent advancements in this modality might offer physicians the option to screen for colorectal lesions noninvasively. PMID:24597367

  2. Orion Capsule Handling Qualities for Atmospheric Entry

    Science.gov (United States)

    Tigges, Michael A.; Bihari, Brian D.; Stephens, John-Paul; Vos, Gordon A.; Bilimoria, Karl D.; Mueller, Eric R.; Law, Howard G.; Johnson, Wyatt; Bailey, Randall E.; Jackson, Bruce

    2011-01-01

    Two piloted simulations were conducted at NASA's Johnson Space Center using the Cooper-Harper scale to study the handling qualities of the Orion Command Module capsule during atmospheric entry flight. The simulations were conducted using high fidelity 6-DOF simulators for Lunar Return Skip Entry and International Space Station Return Direct Entry flight using bank angle steering commands generated by either the Primary (PredGuid) or Backup (PLM) guidance algorithms. For both evaluations, manual control of bank angle began after descending through Entry Interface into the atmosphere until drogue chutes deployment. Pilots were able to use defined bank management and reversal criteria to accurately track the bank angle commands, and stay within flight performance metrics of landing accuracy, g-loads, and propellant consumption, suggesting that the pilotability of Orion under manual control is both achievable and provides adequate trajectory performance with acceptable levels of pilot effort. Another significant result of these analyses is the applicability of flying a complex entry task under high speed entry flight conditions relevant to the next generation Multi Purpose Crew Vehicle return from Mars and Near Earth Objects.

  3. [Anticonvulsant and psychotropic effects of topamax capsules].

    Science.gov (United States)

    Kalinin, V V; Zheleznova, E V; Sokolova, L V; Zemlianaia, A A

    2009-01-01

    Anticonvulsant and psychotropic effects of "Topamax capsules"(TC) were compared to a traditional form of topiramate (TFT) and some other anticonvulsant drugs (ACD). Thirty-six patients (12 men and 24 women) with partial temporary epilepsy were examined. Sixteen patients received TFT in tablets and 20 patients received ACD before the beginning of the study. Drug effect was assessed by frequency of seizures and some neuropsychiatric parameters. The results revealed that TC was comparable to TFT and ACD in the reduction of seizures of any semiotics. After 3 months of therapy, total MMSE scores increased from 27 to 28. There were less perseverant errors and more right responses in the WCST. Verbal fluency and memory measured with Sunderland test improved as well. TC led to decreased latencies of negative responses in the WCST and increased verbal fluency compared to TFT. Patients who received TFT prior to TC did fewer errors in the WCST than patients who received ACD prior to TC. Verbal fluency improved compared to patients who received other ACD. At the same time, a somewhat increase of paranoid signs on the scale SCL-90 was noted in the group treated with topiramate only. It has been concluded that TC has an activating effect on frontal brain areas.

  4. BC Alaska-Canada gas pipeline

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, K. [BP Canada Energy Company, Calgary, AB (Canada). BP Alaska Canada Gas Pipelines

    2006-07-01

    The Alaska natural gas pipeline project was discussed in relation to the Canadian oil and gas industry and pipeline infrastructure. Total project costs for the pipeline were estimated at approximately $20 billion. Options out of Alberta include increasing existing capacity to the west coast, as well as expanding pipeline capacity to supply midwest and east coast markets. Existing pipeline systems will be expanded, and a new pipeline from Alaska to Chicago has been proposed. The gas pipeline project is expected to be the largest private construction project in the history of North America, and will provide 6500 jobs in both the United States and Canada. Project challenges to date have included the development of relationships with Aboriginals and First Nations groups in Canada and the United States, as well as ensuring access to efficient, competitive market-based regulatory processes. Project risks to date have included capital and operating cost over-runs, regulatory and legal delays, completion risks, and commodity price risks. Stranded gas act processes were discussed, as well as fiscal contracts related to the legislative and public process. Elements of the fiscal contract were provided, as well as details of First Nations relationships and Crown consultation processes. tabs., figs.

  5. Modelling of geomagnetic induction in pipelines

    Directory of Open Access Journals (Sweden)

    L. Trichtchenko

    Full Text Available Geomagnetic field variations induce telluric currents in pipelines, which modify the electrochemical conditions at the pipe/soil interface, possibly contributing to corrosion of the pipeline steel. Modelling of geomagnetic induction in pipelines can be accomplished by combining several techniques. Starting with geomagnetic field data, the geoelectric fields in the absence of the pipeline were calculated using the surface impedance derived from a layered-Earth conductivity model. The influence of the pipeline on the electric fields was then examined using an infinitely long cylinder (ILC model. Pipe-to-soil potentials produced by the electric field induced in the pipeline were calculated using a distributed source transmission line (DSTL model. The geomagnetic induction process is frequency dependent; therefore, the calculations are best performed in the frequency domain, using a Fourier transform to go from the original time domain magnetic data, and an inverse Fourier transform at the end of the process, to obtain the pipe-to-soil potential variation in the time domain. Examples of the model calculations are presented and compared to observations made on a long pipeline in the auroral zone.

    Key words. Geomagnetism and paleomagnetism (geo-magnetic induction

  6. The LOFAR Known Pulsar Data Pipeline

    CERN Document Server

    Alexov, A; Mol, J D; Stappers, B; van Leeuwen, J

    2010-01-01

    Transient radio phenomena and pulsars are one of six LOFAR Key Science Projects (KSPs). As part of the Transients KSP, the Pulsar Working Group (PWG) has been developing the LOFAR Pulsar Data Pipelines to both study known pulsars as well as search for new ones. The pipelines are being developed for the Blue Gene/P (BG/P) supercomputer and a large Linux cluster in order to utilize enormous amounts of computational capabilities (50Tflops) to process data streams of up to 23TB/hour. The LOFAR pipeline output will be using the Hierarchical Data Format 5 (HDF5) to efficiently store large amounts of numerical data, and to manage complex data encompassing a variety of data types, across distributed storage and processing architectures. We present the LOFAR Known Pulsar Data Pipeline overview, the pulsar beam-formed data format, the status of the pipeline processing as well as our future plans for developing the LOFAR Pulsar Search Pipeline. These LOFAR pipelines and software tools are being developed as the next gen...

  7. Current pipelines for neglected diseases.

    Directory of Open Access Journals (Sweden)

    Paolo di Procolo

    2014-09-01

    Full Text Available This paper scrutinises pipelines for Neglected Diseases (NDs, through freely accessible and at-least-weekly updated trials databases. It updates to 2012 data provided by recent publications, and integrates these analyses with information on location of trials coordinators and patients recruitment status. Additionally, it provides (i disease-specific information to better understand the rational of investments in NDs, (ii yearly data, to understand the investment trends. The search identified 650 clinical studies. Leishmaniasis, Arbovirus infection, and Dengue are the top three diseases by number of clinical studies. Disease diffusion risk seems to be the most important driver of the clinical trials target choice, whereas the role played by disease prevalence and unmet need is controversial. Number of trials is stable between 2005 and 2010, with an increase in the last two years. Patient recruitment was completed for most studies (57.6%, and Phases II and III account for 35% and 28% of trials, respectively. The primary purpose of clinical investigations is prevention (49.3%, especially for infectious diseases with mosquitoes and sand flies as the vector, and treatment (43.2%, which is the primary target for parasitic diseases Research centres and public organisations are the most important clinical studies sponsors (58.9%, followed by the pharmaceutical industry (24.1%, foundations and non-governmental organisations (9.3%. Many coordinator centres are located in less affluent countries (43.7%, whereas OECD countries and BRICS account for 34.7% and 17.5% of trials, respectively. Information was partially missing for some parameters. Notwithstanding, and despite its descriptive nature, this research has enhanced the evidence of the literature on pipelines for NDs. Future contributions may further investigate whether trials metrics are consistent with the characteristics of the interested countries and the explicative variables of trials location

  8. Current pipelines for neglected diseases.

    Science.gov (United States)

    di Procolo, Paolo; Jommi, Claudio

    2014-09-01

    This paper scrutinises pipelines for Neglected Diseases (NDs), through freely accessible and at-least-weekly updated trials databases. It updates to 2012 data provided by recent publications, and integrates these analyses with information on location of trials coordinators and patients recruitment status. Additionally, it provides (i) disease-specific information to better understand the rational of investments in NDs, (ii) yearly data, to understand the investment trends. The search identified 650 clinical studies. Leishmaniasis, Arbovirus infection, and Dengue are the top three diseases by number of clinical studies. Disease diffusion risk seems to be the most important driver of the clinical trials target choice, whereas the role played by disease prevalence and unmet need is controversial. Number of trials is stable between 2005 and 2010, with an increase in the last two years. Patient recruitment was completed for most studies (57.6%), and Phases II and III account for 35% and 28% of trials, respectively. The primary purpose of clinical investigations is prevention (49.3%), especially for infectious diseases with mosquitoes and sand flies as the vector, and treatment (43.2%), which is the primary target for parasitic diseases Research centres and public organisations are the most important clinical studies sponsors (58.9%), followed by the pharmaceutical industry (24.1%), foundations and non-governmental organisations (9.3%). Many coordinator centres are located in less affluent countries (43.7%), whereas OECD countries and BRICS account for 34.7% and 17.5% of trials, respectively. Information was partially missing for some parameters. Notwithstanding, and despite its descriptive nature, this research has enhanced the evidence of the literature on pipelines for NDs. Future contributions may further investigate whether trials metrics are consistent with the characteristics of the interested countries and the explicative variables of trials location, target

  9. Current pipelines for neglected diseases.

    Science.gov (United States)

    di Procolo, Paolo; Jommi, Claudio

    2014-09-01

    This paper scrutinises pipelines for Neglected Diseases (NDs), through freely accessible and at-least-weekly updated trials databases. It updates to 2012 data provided by recent publications, and integrates these analyses with information on location of trials coordinators and patients recruitment status. Additionally, it provides (i) disease-specific information to better understand the rational of investments in NDs, (ii) yearly data, to understand the investment trends. The search identified 650 clinical studies. Leishmaniasis, Arbovirus infection, and Dengue are the top three diseases by number of clinical studies. Disease diffusion risk seems to be the most important driver of the clinical trials target choice, whereas the role played by disease prevalence and unmet need is controversial. Number of trials is stable between 2005 and 2010, with an increase in the last two years. Patient recruitment was completed for most studies (57.6%), and Phases II and III account for 35% and 28% of trials, respectively. The primary purpose of clinical investigations is prevention (49.3%), especially for infectious diseases with mosquitoes and sand flies as the vector, and treatment (43.2%), which is the primary target for parasitic diseases Research centres and public organisations are the most important clinical studies sponsors (58.9%), followed by the pharmaceutical industry (24.1%), foundations and non-governmental organisations (9.3%). Many coordinator centres are located in less affluent countries (43.7%), whereas OECD countries and BRICS account for 34.7% and 17.5% of trials, respectively. Information was partially missing for some parameters. Notwithstanding, and despite its descriptive nature, this research has enhanced the evidence of the literature on pipelines for NDs. Future contributions may further investigate whether trials metrics are consistent with the characteristics of the interested countries and the explicative variables of trials location, target

  10. Management of a multi-product pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Bettoli, R.; Iacovoni, A. [Nuovo Pignone S.p.A., Roma (Italy). Div. Sistemi Automazione; Holden, D. [LICconsult, Stockton-on-Tees (United Kingdom)

    1996-09-01

    The paper describes the SCADA (System Control and Data Acquisition) Tele-supervisory System for the Kandla-Bhatinda (KBPL) multi-product pipeline. The KBPL pipeline is 1,443 km in length; it is to carry petroleum products, in a batch cycle organization, from the Kandla foreshore terminal to Bhatinda. It consists of two inlet stations, four pumping stations, five delivery stations, and two terminal stations, and is equipped with a total of 85 block valves. All the stations have the capability for launching and receiving scrapers. The SCADA system consists of 10 Station Control Centers (SCC) and one Master Control Center (MCC), all located along the pipeline.

  11. Pipelines: prebuild remains focus of attention

    Energy Technology Data Exchange (ETDEWEB)

    1980-04-21

    Progress on the prebuilding of the Alaska Highway Pipeline continues to dominate the Canadian pipeline scene as the deadline nears for decision making on several aspects of the project. If obstacles are removed in time for the western leg of the prebuild to proceed on the revised schedule, facilities for gas deliveries to California should be completed by fall 1980. Financing negotiations are continuing in both the US and Canada. Pipeline projects in Canada during 1980 are listed by line type, including gas transmission lines, crude oil and products lines, gas gathering systems, waterflood systems, and new projects not called gas transmission lines.

  12. The Iran-Pakistan-India Pipeline Project

    OpenAIRE

    Basit, Saira

    2008-01-01

    The planned Iran-Pakistan-India natural-gas pipeline (IPI Pipeline) has been in the Asian spotlight for many years and its full realisation would be politically ground-breaking. Its energy-supply route is planned to cross the political fault line between the two rivals Pakistan and India, who would thus be bound to cooperate with one another. In fact, planning the Pipeline is the first time in history that the two countries have ever even negotiated on a trilateral project. Additionally, intr...

  13. Future impact on natural gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Croom, J.H.

    1982-01-01

    The future for natural gas pipelines is forecast by examining the sources and uses of energy today and projecting respective changes. No significant changes are expected over the next 20 yr in natural gas usage, but regionally, some demand shift could impact certain gas transmission facilities. The conclusion is that natural gas will continue to displace oil in some stationary uses, while coal will displace natural gas in some power plant and feedstock applications. Although these shifts will result in some regional construction activity, they will probably not necessitate major arterial increases to the pipeline network. However, significant changes in supply sources may have a major impact on pipeline planning and construction.

  14. Power system for electric heating of pipelines

    OpenAIRE

    Novik, Frode Karstein

    2008-01-01

    Direct electrical heating (DEH) of pipelines is a flow assurance method that has proven to be a good and reliable solution for preventing the formation of hydrates and wax in multiphase flow lines. The technology is installed on several pipelines in the North Sea and has become StatoilHydros preferred method for flow assurance. Tyrihans is the newest installation with 10 MW DEH for a 43 km pipline. However, the pipeline represents a considerable single-phase load which makes the power system ...

  15. Pipelines jockey to serve Florida gas market

    International Nuclear Information System (INIS)

    This paper reports that Florida Gas Transmission Corp. (FGT), Houston, appears to have taken the lead in competition to serve Florida's growing gas markets. Florida Power and Light (FPL), Miami, decided to reserve transportation capacity on FGT's proposed Phase III expansion rather than the Sun Coast pipeline proposed by United Gas Pipe Line Co. (UGPL), Houston, and Coastal Corp. unit ANR Pipeline Co., Detroit (OGJ, Aug. 31, p. 31). Withdrawal of FPL, Florida's largest electric utility, from Sun Coast left the proposed 560 mile, 400 MMcfd intrastate gas transmission pipeline with only one major prospective client, Florida Power Corp., St. Petersburg. That forces UGPL and ANR to dissolve the partnership

  16. A Survey of Visual Analytic Pipelines

    Institute of Scientific and Technical Information of China (English)

    Xu-Meng Wang; Tian-Ye Zhang; Yu-Xin Ma; Jing Xia; Wei Chen

    2016-01-01

    Visual analytics has been widely studied in the past decade. One key to make visual analytics practical for both research and industrial applications is the appropriate definition and implementation of the visual analytics pipeline which provides effective abstractions for designing and implementing visual analytics systems. In this paper we review the previous work on visual analytics pipelines and individual modules from multiple perspectives: data, visualization, model and knowledge. In each module we discuss various representations and descriptions of pipelines inside the module, and compare the commonalities and the differences among them.

  17. Integrating sustainable growth into export pipeline projects

    International Nuclear Information System (INIS)

    Full text: Sustainable growth in the energy industry is rapidly expanding beyond the conceptual stage. Policies addressing the three principles of Sustainable Development are being established and strategies to execute these policies are being developed and implemented in the field. Conoco is developing a strong corporate culture around sustainable growth; and, pipeline systems play a vital role in delivering the triple bottom line results for our stake holders. This paper will highlight some of the key focal points by Conoco Inc., in each phase of pipeline project development, execution, and operation to make pipeline projects a contributor to Conoco's sustainable growth success, and shares some lessons learned

  18. Python Bindings for the Common Pipeline Library

    Science.gov (United States)

    Streicher, O.; Weilbacher, P. M.

    2012-09-01

    The Common Pipeline Library is a set of routines written by ESO to provide a standard interface for VLT instrument data reduction tasks (“pipelines”). To control these pipelines from Python, we developed a wrapper called PYTHON-CPL that allows one to conveniently work interactively and to process data as part of an automated data reduction system. The package will be used to implement the MUSE pipeline in the AstroWISE data management system. We describe the features and design of the package.

  19. 49 CFR 192.629 - Purging of pipelines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Purging of pipelines. 192.629 Section 192.629... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Operations § 192.629 Purging of pipelines. (a) When a pipeline is being purged of air by use of gas, the gas must be released into one end of the line in...

  20. 49 CFR 192.513 - Test requirements for plastic pipelines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Test requirements for plastic pipelines. 192.513 Section 192.513 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Test requirements for plastic pipelines. (a) Each segment of a plastic pipeline must be tested...

  1. Knowledge Pipeline: A Task Oriented Way to Implement Knowledge Management

    International Nuclear Information System (INIS)

    Concept of knowledge pipeline: There are many pipelines named by tasks or business processes in an organization. Knowledge contributors put knowledge to its corresponding pipelines. A maintenance team could keep the knowledge in pipelines clear and valid. Users could get knowledge just like opening a faucet in terms of their tasks or business processes

  2. 49 CFR 192.627 - Tapping pipelines under pressure.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Tapping pipelines under pressure. 192.627 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Operations § 192.627 Tapping pipelines under pressure. Each tap made on a pipeline under pressure must be performed by a crew qualified to...

  3. Pipeline repair technology damage and repair assessment of pipelines with high residual stresses

    OpenAIRE

    Høie, Øyvind

    2015-01-01

    Today in the offshore industry, there are an increasing number of pipelines that require both maintenance and repair. A wide specter of research in pipeline repair technology is available. Damage to a pipeline could be a quite complex event to analyze, due to the many different combinations of internal pipe stresses and damage types. Standards, such as DNV and ASTM have experimental based assessment methods for evaluating many of these damage combinations, however, there are some of these met...

  4. 77 FR 19414 - Pipeline Safety: Public Comment on Leak and Valve Studies Mandated by the Pipeline Safety...

    Science.gov (United States)

    2012-03-30

    ... Natural Gas Pipelines The contractor will conduct a study on the ability of transmission pipeline facility... study will evaluate Class 3 and Class 4 areas of natural gas transmission pipelines. The contractor must... valves. This review will be for hazardous liquid and natural gas pipelines and determine how...

  5. A Novel Method to Enhance Pipeline Trajectory Determination Using Pipeline Junctions.

    Science.gov (United States)

    Sahli, Hussein; El-Sheimy, Naser

    2016-01-01

    Pipeline inspection gauges (pigs) have been used for many years to perform various maintenance operations in oil and gas pipelines. Different pipeline parameters can be inspected during the pig journey. Although pigs use many sensors to detect the required pipeline parameters, matching these data with the corresponding pipeline location is considered a very important parameter. High-end, tactical-grade inertial measurement units (IMUs) are used in pigging applications to locate the detected problems of pipeline using other sensors, and to reconstruct the trajectories of the pig. These IMUs are accurate; however, their high cost and large sizes limit their use in small diameter pipelines (8″ or less). This paper describes a new methodology for the use of MEMS-based IMUs using an extended Kalman filter (EKF) and the pipeline junctions to increase the position parameters' accuracy and to reduce the total RMS errors even during the unavailability of above ground markers (AGMs). The results of this new proposed method using a micro-electro-mechanical systems (MEMS)-based IMU revealed that the position RMS errors were reduced by approximately 85% compared to the standard EKF solution. Therefore, this approach will enable the mapping of small diameter pipelines, which was not possible before. PMID:27110780

  6. Pipeline rules of thumb handbook a manual of quick, accurate solutions to everyday pipeline engineering problems

    CERN Document Server

    McAllister, EW

    2014-01-01

    Presented in easy-to-use, step-by-step order, Pipeline Rules of Thumb Handbook is a quick reference for day-to-day pipeline operations. For more than 35 years, the Pipeline Rules of Thumb Handbook has served as the ""go-to"" reference for solving even the most day-to-day vexing pipeline workflow problems. Now in its 8th edition, this handbook continues to set the standard by which all other piping books are judged. Along with over 30% new or updated material regarding codes, construction processes, and equipment, this book continues to offer hundreds of ""how-to"" methods and ha

  7. Pipelines in Louisiana, Geographic NAD83, USGS (1999) [pipelines_la_usgs_1999

    Data.gov (United States)

    Louisiana Geographic Information Center — This dataset contains vector line map information of various pipelines throughout the State of Louisiana. The vector data contain selected base categories of...

  8. Regular pipeline maintenance of gas pipeline using technical operational diagnostics methods

    Energy Technology Data Exchange (ETDEWEB)

    Volentic, J. [Gas Transportation Department, Slovensky plynarensky priemysel, Slovak Gas Industry, Bratislava (Slovakia)

    1997-12-31

    Slovensky plynarensky priemysel (SPP) has operated 17 487 km of gas pipelines in 1995. The length of the long-line pipelines reached 5 191 km, distribution network was 12 296 km. The international transit system of long-line gas pipelines ranged 1 939 km of pipelines of various dimensions. The described scale of transport and distribution system represents a multibillion investments stored in the ground, which are exposed to the environmental influences and to pipeline operational stresses. In spite of all technical and maintenance arrangements, which have to be performed upon operating gas pipelines, the gradual ageing takes place anyway, expressed in degradation process both in steel tube, as well as in the anti-corrosion coating. Within a certain time horizon, a consistent and regular application of methods and means of in-service technical diagnostics and rehabilitation of existing pipeline systems make it possible to save substantial investment funds, postponing the need in funds for a complex or partial reconstruction or a new construction of a specific gas section. The purpose of this presentation is to report on the implementation of the programme of in-service technical diagnostics of gas pipelines within the framework of regular maintenance of SPP s.p. Bratislava high pressure gas pipelines. (orig.) 6 refs.

  9. A Novel Method to Enhance Pipeline Trajectory Determination Using Pipeline Junctions

    Directory of Open Access Journals (Sweden)

    Hussein Sahli

    2016-04-01

    Full Text Available Pipeline inspection gauges (pigs have been used for many years to perform various maintenance operations in oil and gas pipelines. Different pipeline parameters can be inspected during the pig journey. Although pigs use many sensors to detect the required pipeline parameters, matching these data with the corresponding pipeline location is considered a very important parameter. High-end, tactical-grade inertial measurement units (IMUs are used in pigging applications to locate the detected problems of pipeline using other sensors, and to reconstruct the trajectories of the pig. These IMUs are accurate; however, their high cost and large sizes limit their use in small diameter pipelines (8″ or less. This paper describes a new methodology for the use of MEMS-based IMUs using an extended Kalman filter (EKF and the pipeline junctions to increase the position parameters’ accuracy and to reduce the total RMS errors even during the unavailability of above ground markers (AGMs. The results of this new proposed method using a micro-electro-mechanical systems (MEMS-based IMU revealed that the position RMS errors were reduced by approximately 85% compared to the standard EKF solution. Therefore, this approach will enable the mapping of small diameter pipelines, which was not possible before.

  10. A Novel Method to Enhance Pipeline Trajectory Determination Using Pipeline Junctions.

    Science.gov (United States)

    Sahli, Hussein; El-Sheimy, Naser

    2016-01-01

    Pipeline inspection gauges (pigs) have been used for many years to perform various maintenance operations in oil and gas pipelines. Different pipeline parameters can be inspected during the pig journey. Although pigs use many sensors to detect the required pipeline parameters, matching these data with the corresponding pipeline location is considered a very important parameter. High-end, tactical-grade inertial measurement units (IMUs) are used in pigging applications to locate the detected problems of pipeline using other sensors, and to reconstruct the trajectories of the pig. These IMUs are accurate; however, their high cost and large sizes limit their use in small diameter pipelines (8″ or less). This paper describes a new methodology for the use of MEMS-based IMUs using an extended Kalman filter (EKF) and the pipeline junctions to increase the position parameters' accuracy and to reduce the total RMS errors even during the unavailability of above ground markers (AGMs). The results of this new proposed method using a micro-electro-mechanical systems (MEMS)-based IMU revealed that the position RMS errors were reduced by approximately 85% compared to the standard EKF solution. Therefore, this approach will enable the mapping of small diameter pipelines, which was not possible before.

  11. Optimising of pipeline maintenance using deposit profile technology

    OpenAIRE

    Dahl, Johannes

    2014-01-01

    With an aging pipeline system, the petroleum industry is experiencing new challenges in maintaining the pipeline integrity. In the Master’s thesis, a method and technology for internal pipeline diameter detection is presented. By measuring the pressure signature during a conventional utility pigging operation, the changes in internal pipeline diameter are detected. The method is evaluated and its applicability for optimising the pipeline maintenance programme is discussed. The first par...

  12. Sinopec Fuels Development of Pipelines in East China

    Institute of Scientific and Technical Information of China (English)

    Li Xuemei

    2004-01-01

    @@ Crude pipeline completed in Yangtze River Delta The Ningbo-Shanghai-Nanjing crude pipeline was recently wound up for construction following completion of the subsea segment in Hangzhou Bay,the last part of the pipeline. The 711 mm-diameter crude pipeline, designed and constructed by Sinopec, adopts the advanced SCADA system for full automation control. The pipeline is designed to have an annual crude transmission capacity of 20million tons.

  13. Australia's changing natural gas and pipeline industry

    International Nuclear Information System (INIS)

    The future is bright for continued development of Australia's natural gas pipeline infrastructure, as well as for privatization and private energy infrastructure growth. Gas demands are growing and the development of open access principles for all natural gas transmission and distribution pipelines heralds a much more market focused industry. Within the next few years gas-on-gas competition will apply to supply, pipelines, and retail marketing. No longer will operators be able to pass on high costs resulting from inefficiencies to their customers. This article describes the changing Australian gas industry, evaluates the drivers for change and looks at ways the industry is responding to new regulatory regimes and the development and use of new pipeline technology

  14. Citizenship program in near communities of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Mascarenhas, Carina R.; Vilas Boas, Ianne P. [TELSAN Engenharia, Belo Horizonte, MG (Brazil); Bourscheid, Pitagoras [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    During the construction of a pipeline, the IENE - Engineering Unit of PETROBRAS, responsible for the construction and erection of pipelines and related plants in northeastern Brazil, crossed more than 7 states and 250 counties, had implemented a social responsibility program, in special a citizenship program. This action was the result of community studies located near of the pipelines AID - Direct Influence Area (438 yards right and left of the pipeline) and through the evidence that those locations were poor and have no personal documents and citizen position in society. This paper intents to share the experience of IENE about its citizen program that worked in three big lines: community mobilization; citizenship qualification; and citizenship board. This last one, turns possible to people obtains theirs personal documents and exercise the plenitude of citizenship. (author)

  15. Analytical Quality check of oil based blend in Flaxilip capsule

    Directory of Open Access Journals (Sweden)

    Rajashree Rane

    2014-12-01

    Full Text Available Analysis of capsules containing blend in the powder form is easy, but it is bit difficult to analyse the soft gelatin capsule containing oil based blend. The purpose of this study was to develop test parameters to determine and supervise the quality of such herbal capsule formulation. Five different lots of soft gelatin Flaxilip capsule containing Linseed oil, Guggulu processed with linseed oil, Garlic oil, Fenugreek oil along with Soyabean oil as an excipient , were selected for the study. All the five lots were subjected to general capsule tests such as determination of average weight and disintegration time. Results obtained were around 1.3500g and 10minutes respectively. Specific test parameters applicable for oils like specific gravity, refractive index, acid value, peroxide value, saponification value, iodine value were applied quantitatively for quality evaluation. Standardised suitable classical methods were applied. Results in all the five lots were found to be well within inhouse limit. All the samples were subjected to heavy metals and microbiological testing. Compliance of corresponding findings with the standard pharmacopoeial guidelines assure the safe intake of the drug. For getting the better effect, the Guggulu that is Commiphora mukul used in the formulation was processed with linseed oil. Its presence was confirmed by carrying out HPTLC for E and Z guggulu sterone. Resemblance of spots at Rf ranging from 0.36 to 0.38 and 0.43 to 0.45 in Toluene : Acetone (9:1 system showed the presence of gugulu in blends of all the lots. Hence by applying all these test parameters one can ensure the quality of the soft gelatin ayurvedic capsule formulation containing oily base like in Flaxilip capsule.

  16. Developing Pipeline Transportation in West China

    Institute of Scientific and Technical Information of China (English)

    Yang Chenghan; Wang Wei

    1997-01-01

    @@ Since the late 1980s, focus of exploration and development for oil & gas has been diverted to thewest of China, resulting in the discovery and development of Shaanbei gas field followed by large-scale exploration and development of Tarim,Turpan and Hami basins. Responding to this situation, pipeline construction focus has also been transferred to west China where large-scale development of pipeline transportation, an opportunity as well as a challenge, is expected.

  17. Market Brief : Turkey oil and gas pipelines

    International Nuclear Information System (INIS)

    This report presented some quick facts about oil and gas pipelines in Turkey and presented opportunities for trade. The key players and customers in the oil and gas sector were described along with an export check list. Turkey is looking into becoming an energy bridge between oil and gas producing countries in the Middle East, Central Asia and Europe. The oil and gas sectors are dominated by the Turkish Petroleum Corporation, a public enterprise dealing with exploration and production, and the State Pipeline Corporation which deals with energy transmission. They are also the key buyers of oil and gas equipment in Turkey. There are several pipelines connecting countries bordering the Caspian Sea. Opportunities exist in the areas of engineering consulting as well as contracting services for oil and gas pipeline transmission and distribution. Other opportunities lie in the area of pipeline construction, rehabilitation, materials, equipment, installation, and supervisory control and data acquisition (SCADA) systems. Currently, the major players are suppliers from Italy, Germany, France, United States and Japan. Turkey has no trade barriers and imported equipment and materials are not subjected to any restriction. The oil and gas market in Turkey expected in increase by an average annual growth rate of 15 per cent from 2001 to 2003. A brief description of pipeline projects in Turkey was presented in this report along with a list of key contacts and support services. 25 refs., 1 append

  18. Astronomical pipeline processing using fuzzy logic

    Science.gov (United States)

    Shamir, Lior

    In the past few years, pipelines providing astronomical data have been becoming increasingly important. The wide use of robotic telescopes has provided significant discoveries, and sky survey projects such as SDSS and the future LSST are now considered among the premier projects in the field astronomy. The huge amount of data produced by these pipelines raises the need for automatic processing. Astronomical pipelines introduce several well-defined problems such as astronomical image compression, cosmic-ray hit rejection, transient detection, meteor triangulation and association of point sources with their corresponding known stellar objects. We developed and applied soft computing algorithms that provide new or improved solutions to these growing problems in the field of pipeline processing of astronomical data. One new approach that we use is fuzzy logic-based algorithms, which enables the automatic analysis of the astronomical pipelines and allows mining the data for not-yet-known astronomical discoveries such as optical transients and variable stars. The developed algorithms have been tested with excellent results on the NightSkyLive sky survey, which provides a pipeline of 150 astronomical pictures per hour, and covers almost the entire global night sky.

  19. GRAVITY PIPELINE TRANSPORT FOR HARDENING FILLING MIXTURES

    Directory of Open Access Journals (Sweden)

    Leonid KROUPNIK

    2015-12-01

    Full Text Available In underground mining of solid minerals becoming increasingly common development system with stowing hardening mixtures. In this case the natural ore array after it is replaced by an artificial excavation of solidified filling mixture consisting of binder, aggregates and water. Such a mixture is prepared on the surface on special stowing complexes and transported underground at special stowing pipelines. However, it is transported to the horizons of a few kilometers, which requires a sustainable mode of motion of such a mixture in the pipeline. Hardening stowing mixture changes its rheological characteristics over time, which complicates the calculation of the parameters of pipeline transportation. The article suggests a method of determining the initial parameters of such mixtures: the status coefficient, indicator of transportability, coefficient of hydrodynamic resistance to motion of the mixture. These indicators characterize the mixture in terms of the possibility to transport it through pipes. On the basis of these indicators is proposed methodology for calculating the parameters of pipeline transport hardening filling mixtures in drift mode when traffic on the horizontal part of the mixture under pressure column of the mixture in the vertical part of the backfill of the pipeline. This technique allows stable operation is guaranteed to provide pipeline transportation.

  20. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  1. Finding the solution for incomplete small bowel capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    José; Cotter; Francisca; Dias; de; Castro; Joana; Magalhes; Maria; Joo; Moreira; Bruno; Rosa

    2013-01-01

    AIM:To evaluate whether the use of real time viewer(RTV)and administration of domperidone to patients with delayed gastric passage of the capsule could reduce the rate of incomplete examinations(IE)and improve the diagnostic yield of small bowel capsule endoscopy(SBCE).METHODS:Prospective single center interventional study,from June 2012 to February 2013.Capsule location was systematically checked one hour after ingestion using RTV.If it remained in the stomach,the patient received 10 mg domperidone per os and the location of the capsule was rechecked after 30 min.If the capsule remained in the stomach a second dose of10 mg of domperidone was administered orally.After another 30 min the position was rechecked and if the capsule remained in the stomach,it was passed into the duodenum by upper gastrointestinal(GI)endoscopy.The rate of IE and diagnostic yield of SBCE were compared with those of examinations performed before the use of RTV or domperidone in our Department(control group,January 2009-May 2012).RESULTS:Both groups were similar regarding age,sex,indication,inpatient status and surgical history.The control group included 307 patients,with 48(15.6%)IE.The RTV group included 82 patients,with3(3.7%)IE,P=0.003.In the control group,average gastric time was significantly longer in patients with IE than in patients with complete examination of the small bowel(77 min vs 26 min,P=0.003).In the RTV group,the capsule remained in the stomach one hour after ingestion in 14/82 patients(17.0%)vs 48/307(15.6%)in the control group,P=0.736.Domperidone did not significantly affect small bowel transit time(260min vs 297 min,P=0.229).The capsule detected positive findings in 39%of patients in the control group and 49%in the RTV group(P=0.081).CONCLUSION:The use of RTV and selective administration of domperidone to patients with delayed gastric passage of the capsule significantly reduces incomplete examinations,with no effect on small bowel transit time or diagnostic yield.

  2. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant.

  3. FEM analysis of escape capsule suffered to gas explosion

    Science.gov (United States)

    Li, Chang-lu; Mei, Rui-bin; Li, Chang-sheng; Cai, Ban; Liu, Xiang-hua

    2013-05-01

    Escape capsules are new devices for underground coal mines that provide air, water, food and supplies in the event of an emergency in where miners are unable to escape. It is difficult to carry out the experiments of explosion and safety because the danger and nonrepeatability of explosion. The structure deformation and distribution of equivalent stress has been investigated under different impact pressure conditions including unimodal and bimodal loads based on the FEM and software LS-DYNA. The results show that the distribution of deformation and equivalent stress has the same trend on the same surface with the increment of explosion pressure. The deformation and stress are larger with side impact pressure compared with that of the same front impact pressure. Furthermore, the maximum equivalent stress is 246MPa and 260MPa on the front and sides of capsule with five times for national standard impact pressure 1.5MPa. Under these conditions, the deformation is less than about 9.97mm and 10.47mm, respectively. When the front impact pressure is 2.0MPa, the deformation of capsule still belongs to elasticity but the less plastic deformation occurs on the Ushape stiffening channels with the same side impact pressure. However, it is safe for capsule structure because the equivalent stress 283MPa is much less than the tensile strength. It is noted that bimodal load accelerates the capsule deformation so that it is more dangerous compared with unimodal load.

  4. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  5. Improvement and utilization of irradiation capsule technology in HANARO

    International Nuclear Information System (INIS)

    Several improvements of irradiation capsule technology regarding irradiation test parameters, such as temperature and neutron flux/fluence, and regarding instrumentation have progressed at HANARO since the last KAERI-JAERI joint seminar held in 2008. The standard HANARO capsule technology that was developed for use in a commercial power plant temperature of about 300degC was improved to apply to a temperature range of 100-1000degC for the irradiation test of materials of new research reactors and future nuclear systems. Low-flux and long-term irradiation technologies have been developed at HANARO. As a beginning step of the localization of capsule instrumentation technology, the irradiation performance of a domestically produced thermocouple and LVDT will be examined at HANARO. The accuracy of an evaluation of neutron fluence and precise welding technology are also being examined at HANARO. Based on these accumulated capsule technologies, a HANARO irradiation capsule system is being actively utilized for the national R and D programme on commercial nuclear reactors and nuclear fuel cycle technology in Korea. HANARO has recently started the irradiation support of R and D relevant to future nuclear systems including SMART, VHTR, and SFR, and HANARO is preparing new support relevant to new research and Fusion reactors. (author)

  6. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  7. FTIR-ATR imaging of coated oil capsules

    International Nuclear Information System (INIS)

    Complete text of publication follows. Coated oil capsules are used to deliver new functional food ingredients. In this study spherical capsules were investigated containing a core with fish oil coated with a transparent gelatine layer. The remaining actives are within a hard coating, which is applied on the gelatine capsules. For the microstructural characterization of the coating the following techniques were used: Fourier Transform Infrared (FTIR) microscopy using an Attenuated Total Reflection (ATR) crystal, Light Microscopy (LM), X-ray microtomography (μCT) and Scanning Electron Microscopy (SEM). For FTIR-ATR imaging the oil capsules were embedded in epoxy resin. The embedded sample was trimmed in a microtome using a glass knife for the initial rough trimming. For the final fracture a diamond knife was used to obtain the best possible surface. A Ge-crystal was brought in contact with the surface of interest. LM images were obtained using the visible light camera of the FTIR system. A principal component analysis was performed on the FTIR-ATR imaging showing the spatial distribution of some of the compounds. This study demonstrated that imaging techniques can be used to analyse the microstructure of coated oil capsules. Correlative microscopy of techniques like FTIR-ATR imaging, LM, XRT and SEM-EDX results in useful information about the spatial distribution of the chemical compounds and layer thickness of solid food samples.

  8. Diluent evaluation for bitumen pipelining

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, P.; Cooper, S.; Alem, T. [National Centre for Upgrading Technology, Devon, AB (Canada)

    2009-07-01

    Oil sands crudes are expected to represent over 75 per cent of the crude produced in Western Canada. Since bitumen is too viscous to be shipped in pipelines, it must be diluted with a lighter hydrocarbon. Although thermal processing could be used together with a smaller quantity of diluent, the resulting fuel would be less stable. This presentation reported on a study that examined the compatibility and stability of virgin and cracked bitumen in natural diluents and synthetic diluents. Diluent ranking for asphaltene stability in virgin bitumen and cracked bitumen was also examined. Four heavy oils and bitumens were used in this study, notably Athabasca bitumen (AB), cracked Athabasca bitumen, heavy oil B and a light crude C. Natural gas condensate and oil sand derived liquids were the 2 diluents used to investigate the insolubility number and solubility blending number of different crudes, diluents and their blends. It was concluded that the stability of different heavy oils can be determined accurately by observing flocculation of asphaltenes. The study also evaluated and ranked the strength of different diluents for keeping asphaltenes soluble in the oil matrix. Although synthetic diluents were found to be better solvents than natural gas condensates for bitumen, the order of the solvent strength was reversed when bitumen was processed. tabs., figs.

  9. Automated pipelines for spectroscopic analysis

    Science.gov (United States)

    Allende Prieto, C.

    2016-09-01

    The Gaia mission will have a profound impact on our understanding of the structure and dynamics of the Milky Way. Gaia is providing an exhaustive census of stellar parallaxes, proper motions, positions, colors and radial velocities, but also leaves some glaring holes in an otherwise complete data set. The radial velocities measured with the on-board high-resolution spectrograph will only reach some 10 % of the full sample of stars with astrometry and photometry from the mission, and detailed chemical information will be obtained for less than 1 %. Teams all over the world are organizing large-scale projects to provide complementary radial velocities and chemistry, since this can now be done very efficiently from the ground thanks to large and mid-size telescopes with a wide field-of-view and multi-object spectrographs. As a result, automated data processing is taking an ever increasing relevance, and the concept is applying to many more areas, from targeting to analysis. In this paper, I provide a quick overview of recent, ongoing, and upcoming spectroscopic surveys, and the strategies adopted in their automated analysis pipelines.

  10. Black powder in gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Sherik, Abdelmounam [Saudi Aramco, Dhahran (Saudi Arabia)

    2009-07-01

    Despite its common occurrence in the gas industry, black powder is a problem that is not well understood across the industry, in terms of its chemical and physical properties, source, formation, prevention or management of its impacts. In order to prevent or effectively manage the impacts of black powder, it is essential to have knowledge of its chemical and physical properties, formation mechanisms and sources. The present paper is divided into three parts. The first part of this paper is a synopsis of published literature. The second part reviews the recent laboratory and field work conducted at Saudi Aramco Research and Development Center to determine the compositions, properties, sources and formation mechanisms of black powder in gas transmission systems. Microhardness, nano-indentation, X-ray Diffraction (XRD), X-ray Fluorescence (XRF) and Scanning Electron Microscopy (SEM) techniques were used to analyze a large number of black powder samples collected from the field. Our findings showed that black powder is generated inside pipelines due to internal corrosion and that the composition of black powder is dependent on the composition of transported gas. The final part presents a summary and brief discussion of various black powder management methods. (author)

  11. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    Science.gov (United States)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  12. The Ruptured Pipeline: Analysis of the Mining Engineering Faculty Pipeline

    Science.gov (United States)

    Poulton, M.

    2011-12-01

    The booming commodities markets of the past seven years have created an enormous demand for economic geologists, mining engineers, and extractive metallurgists. The mining sector has largely been recession proof due to demand drivers coming from developing rather than developed nations. The strong demand for new hires as well as mid-career hires has exposed the weakness of the U.S. university supply pipeline for these career fields. A survey of mining and metallurgical engineering faculty and graduate students was conducted in 2010 at the request of the Society for Mining, Metallurgy, and Exploration. The goals of the surveys were to determine the demographics of the U.S. faculty in mining and metallurgical engineering, the expected faculty turn over by 2010 and the potential supply of graduate students as the future professorate. All Mining Engineering and Metallurgical Engineering degrees in the U.S. are accredited by the Accreditation Board for Engineering and Technology (ABET) and the specific courses required are set by the sponsoring professional society, Society for Mining, Metallurgy, and Exploration. There are 13 universities in the U.S. that offer a degree in Mining Engineering accredited as Mining Engineering and 1 university that grants a Mining Engineering degree accredited under general engineering program requirements. Faculty numbers are approximately 87 tenure track positions with a total undergraduate enrollment of slightly over 1,000 in the 2008-2009 academic year. There are approximately 262 graduate students in mining engineering in the U.S. including 87 Ph.D. students. Mining Engineering department heads have identified 14 positions open in 2010 and 18 positions expected to be open in the next 5 years and an additional 21 positions open by 2020. The current survey predicts a 56% turn over in mining faculty ranks over the next 10 years but a retirement of 100% of senior faculty over 10 years. 63% of graduate students say they are interested in

  13. Biomechanics of the Hip Capsule and Capsule Management Strategies in Hip Arthroscopy.

    Science.gov (United States)

    Nepple, Jeffrey J; Smith, Matthew V

    2015-12-01

    Recent advances in our understanding of the function of the hip capsule have clarified its importance to normal hip function and kinematics. The iliofemoral ligament is the primary stabilizing structure for controlling anterior translation and external rotation of the hip, and is violated by the arthroscopic interportal capsulotomy. Microinstability of the hip occurring after surgical trauma remains a poorly defined clinical entity. In certain at-risk populations, capsular repair should be considered as part of an arthroscopic hip procedure to achieve optimal outcomes and avoid iatrogenic instability (dislocation or microinstability). Despite a lack of conclusive evidence-based indications, we recommend capsular repair in the settings of borderline hip dysplasia (or dysplastic variants such as increased femoral anteversion), hip hypermobility, connective tissue disorders, and traumatic or atraumatic instability. With careful attention to arthroscopic capsular management, adequate exposure can be achieved and reproducibly allow for an effective capsular repair when indicated. PMID:26524549

  14. Pipeline design software and the simulation of liquid propane/butane-light oils pipeline operations

    Energy Technology Data Exchange (ETDEWEB)

    Peters, J. [Monenco AGRA Inc., Calgary, Alberta (Canada)

    1996-12-31

    A comprehensive and integrated suite of computer software routines has been developed to simulate the flow of liquids in pipelines. The fluid properties module accommodates Newtonian and non-Newtonian liquids or mixtures including corrections for changes in properties with temperature and pressure. The hydraulic model calculates pressure drop in single or looped pipelines based on the diameter, route (length) and profile data provided. For multi-product pipelines the hydraulics module estimates energy loss for any sequence of batches given the size and fluid properties of each batch, and the velocity in the pipeline. When the characteristics of existing or proposed pipeline pumps are included, location and size of pumps can be optimized. The effect of heat loss on pressure drop is predicted by invoking the module which calculates the fluid temperature profile based on operating conditions, fluid properties, pipe and insulation conductivity and soil heat transfer data. Modules, created to simulate heater or cooler operations, can be incorporated to compensate for changes in temperature. Input data and calculated results can be presented in a format customized by the user. The simulation software has been successfully applied to multi-product, fuel oil, and non-Newtonian emulsion pipelines. The simulation and operation of a refinery products pipeline for the transportation of propane, butane, gasline, jet and diesel batches will be discussed. The impact of high vapor pressure batches (i.e., propane and butane) on the operation of the pipeline and on the upstream and downstream facilities will be examined in detail.

  15. The Dangers of Pipeline Thinking: How the School-to-Prison Pipeline Metaphor Squeezes out Complexity

    Science.gov (United States)

    McGrew, Ken

    2016-01-01

    In this essay Ken McGrew critically examines the "school-to-prison pipeline" metaphor and associated literature. The origins and influence of the metaphor are compared with the origins and influence of the competing "prison industrial complex" concept. Specific weaknesses in the "pipeline literature" are examined.…

  16. 77 FR 34123 - Pipeline Safety: Public Meeting on Integrity Management of Gas Distribution Pipelines

    Science.gov (United States)

    2012-06-08

    ... published on December 4, 2009, (74 FR 63906). The rule required that operators of gas distribution pipelines... pipeline industry representatives on topics relating to their experiences implementing the distribution... to all. There is no cost to attend. The meeting will be held at the OMNI Hotel, 1300 Houston...

  17. Marine Environmental Protection and Transboundary Pipeline Projects: A Case Study of the Nord Stream Pipeline

    NARCIS (Netherlands)

    Lott, Alexander

    2011-01-01

    The Nord Stream transboundary submarine pipeline, significant for its impact on the EU energy policy, has been a heav- ily debated issue in the Baltic Sea region during the past decade. This is partly due to the concerns over the effects that the pipeline might have on the Baltic Sea as a particular

  18. 75 FR 63774 - Pipeline Safety: Safety of On-Shore Hazardous Liquid Pipelines

    Science.gov (United States)

    2010-10-18

    ..., coating anomalies, in-line inspection data, corrosion coupon data, corrosion inhibitor usage, analysis of... stress corrosion cracking (SCC) in hazardous liquid pipeline systems. Comments should address the public... pipelines from the adverse effects of internal and external corrosion (Subpart H of 49 CFR Part...

  19. 78 FR 41991 - Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding

    Science.gov (United States)

    2013-07-12

    ... July 29, 1993 (ADB-93-03), and the most recent Advisory Bulletin (ADB-11-04) on July 27, 2011, 76 FR... Facilities Caused by Flooding AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT... pipeline facilities caused by severe flooding. This advisory includes actions that operators...

  20. 77 FR 6857 - Pipeline Safety: Notice of Public Meetings on Improving Pipeline Leak Detection System...

    Science.gov (United States)

    2012-02-09

    ... remote control and automatic control valves can be installed to lessen the volume of natural gas and... Capabilities and Research 12:30 p.m. Lunch 1:30 p.m. Panel 3: Considerations for Natural Gas Pipeline Leak Detection Systems 3:30 p.m. Break 3:45 p.m. Panel 4: Natural Gas Pipeline Leak Detection System...

  1. 75 FR 5244 - Pipeline Safety: Integrity Management Program for Gas Distribution Pipelines; Correction

    Science.gov (United States)

    2010-02-02

    ... final rule published December 4, 2009 (74 FR 63906), is correctly revised from February 2, 2010, to... INFORMATION: In FR Doc. E9-28467 appearing on page 63906 in the Federal Register of Friday, December 4, 2009... Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 RIN 2137-AE15 Pipeline...

  2. 75 FR 45591 - Pipeline Safety: Notice of Technical Pipeline Safety Advisory Committee Meetings

    Science.gov (United States)

    2010-08-03

    ... Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477) or view the... complete Privacy Act Statement was published in the Federal Register on April 11, 2000 (65 FR 19477... Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 Pipeline Safety: Notice of...

  3. 76 FR 303 - Pipeline Safety: Safety of On-Shore Hazardous Liquid Pipelines

    Science.gov (United States)

    2011-01-04

    ... October 18, 2010, (75 FR 63774), PHMSA published in the Federal Register an Advance Notice of Proposed... FR 63774), PHMSA published an ANPRM seeking comments on the need for changes to the regulations... Pipeline and Hazardous Materials Safety Administration 49 CFR Part 195 RIN 2137-AE66 Pipeline...

  4. 77 FR 38132 - Pipeline Safety: Meeting of the Technical Pipeline Safety Standards Committee and the Technical...

    Science.gov (United States)

    2012-06-26

    ..., 2000 (65 FR 19477) or view the Privacy Notice at http://www.regulations.gov before submitting any such..., 2000 (65 FR 19477). Information on Services for Individuals With Disabilities For information on... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Meeting of the Technical...

  5. Overview of interstate hydrogen pipeline systems.

    Energy Technology Data Exchange (ETDEWEB)

    Gillette, J .L.; Kolpa, R. L

    2008-02-01

    The use of hydrogen in the energy sector of the United States is projected to increase significantly in the future. Current uses are predominantly in the petroleum refining sector, with hydrogen also being used in the manufacture of chemicals and other specialized products. Growth in hydrogen consumption is likely to appear in the refining sector, where greater quantities of hydrogen will be required as the quality of the raw crude decreases, and in the mining and processing of tar sands and other energy resources that are not currently used at a significant level. Furthermore, the use of hydrogen as a transportation fuel has been proposed both by automobile manufacturers and the federal government. Assuming that the use of hydrogen will significantly increase in the future, there would be a corresponding need to transport this material. A variety of production technologies are available for making hydrogen, and there are equally varied raw materials. Potential raw materials include natural gas, coal, nuclear fuel, and renewables such as solar, wind, or wave energy. As these raw materials are not uniformly distributed throughout the United States, it would be necessary to transport either the raw materials or the hydrogen long distances to the appropriate markets. While hydrogen may be transported in a number of possible forms, pipelines currently appear to be the most economical means of moving it in large quantities over great distances. One means of controlling hydrogen pipeline costs is to use common rights-of-way (ROWs) whenever feasible. For that reason, information on hydrogen pipelines is the focus of this document. Many of the features of hydrogen pipelines are similar to those of natural gas pipelines. Furthermore, as hydrogen pipeline networks expand, many of the same construction and operating features of natural gas networks would be replicated. As a result, the description of hydrogen pipelines will be very similar to that of natural gas pipelines

  6. Inhibitive Effects of Quercetin on Rabbit Tenon Capsule Fibroblasts Proliferation

    Institute of Scientific and Technical Information of China (English)

    Su Liu; Lin Chen

    2005-01-01

    Purpose:To study the inhibitive effects of quercetin (QU) on the fibroblasts proliferation of rabbit Tenon's capsule and its mechanism.Methods: Cultured fibroblasts were exposed to different concentrations of QU solution and investigated by microculture tetrazolium (MTT) assay. The effect of QU was obser ved on cells cycle using the flow cytometer. Besults: QU can suppress the proliferation of rabbit Tenon's capsule fibroblasts in vitro and show a dose-time dependent tendency.Flow cytometer results showed 26.92% cell increase in G1 phase, 23.50% decrease in S phase and 3.42% decrease in G2 phase.Conclusions: QU can suppress the proliferation of rabbit Tenon's capsule fibroblasts in vitro and show a dose-time dependent tendency. QU may effect all phase of cell cycle and inhibit cell proliferation by inhibiting G1 phase transitting to S phase and G2 phase.

  7. Wzy-dependent bacterial capsules as potential drug targets.

    Science.gov (United States)

    Ericsson, Daniel J; Standish, Alistair; Kobe, Bostjan; Morona, Renato

    2012-10-01

    The bacterial capsule is a recognized virulence factor in pathogenic bacteria. It likely works as an antiphagocytic barrier by minimizing complement deposition on the bacterial surface. With the continual rise of bacterial pathogens resistant to multiple antibiotics, there is an increasing need for novel drugs. In the Wzy-dependent pathway, the biosynthesis of capsular polysaccharide (CPS) is regulated by a phosphoregulatory system, whose main components consist of bacterial-tyrosine kinases (BY-kinases) and their cognate phosphatases. The ability to regulate capsule biosynthesis has been shown to be vital for pathogenicity, because different stages of infection require a shift in capsule thickness, making the phosphoregulatory proteins suitable as drug targets. Here, we review the role of regulatory proteins focusing on Streptococcus pneumoniae, Staphylococcus aureus, and Escherichia coli and discuss their suitability as targets in structure-based drug design.

  8. Demonstration of bacteroides capsules by light microscopy and ultrastructural cytochemistry.

    Science.gov (United States)

    Strohm, H; Payne, C M; Ryan, K J

    1983-05-01

    Forty-six anaerobic gram-negative bacilli, including 26 members of the Bacteroides fragilis group (BFG), were examined for capsules by the India ink technic. Thirty-five were encapsulated, including all the BFG strains. As a follow-up, seven of these isolates and two previously studied reference strains (B. fragilis ATCC 23745 and Bacteroides vulgatus ATCC 8482) were examined for capsules by ultrastructural cytochemistry. Using the periodic acid thiocarbohydrazide silver proteinate (PATCSP) method of Thiéry, all the BFG examined were encapsulated. In addition to the reference strains, this included one strain of B. fragilis and four of Bacteroides thetaiotaomicron. One non-BFG strain showed no capsular material. Differences between these results and those reported previously with the ruthenium red technic may reflect species differences in the chemical composition of Bacteroides capsules.

  9. Controllable light capsules employing modified Bessel-Gauss beams

    CERN Document Server

    Gong, Lei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new rou...

  10. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  11. Capsule Performance Optimization in the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2009-10-13

    A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  12. Skaha Lake crossing, innovations in pipeline installation

    International Nuclear Information System (INIS)

    This paper describes the construction of a 10.8 km long NPS16 (406 mm, 16 inch diameter) pipeline, across Skaha Lake, in the south Okanagan valley, British Columbia, Canada. The water crossing is part of the 32 km South Okanagan Natural Gas Pipeline Project (SONG) operated by BC Gas. The pipeline is located in a region dependent on year-round tourism. Therefore, the design and construction was influenced by sensitive environmental and land use concerns. From earlier studies, BC Gas identified surface tow or lay as preferred installation methods. The contractor, Fraser River Pile and Dredge departed from a conventional laybarge methodology after evaluating environmental data and assessing locally available equipment. The contractor proposed a surface tow with multiple surface tie-ins. This approach modification to the ''Surface Tow and Buoy Release Method'' (STBRM) used previously with success on relatively short underwater pipelines. A total of 10 pipe strings, up to 1 km long, were towed into position on the lake and tied-in using a floating platform. The joined pipeline was lowered to the lakebed by divers releasing buoys while tension was maintained from a winch barge at the free end of the pipeline. From analysis and field verified measurement the installation stresses were well below the allowable limits during all phases of construction. The entire construction, including mobilization and demobilization, lasted less than three months, and actual pipelaying less than three weeks. Installation was completed within budget and on schedule, without any environmental or safety related incidents. The SONG pipeline became operational in December 1994

  13. First beryllium capsule implosions on the National Ignition Facility

    Science.gov (United States)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B.; Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F.; Haan, S. W.; Celliers, P. M.; Clark, D. S.; Hammel, B. A.; Kozioziemski, B.; Schneider, M. B.; Marinak, M. M.; Rinderknecht, H. G.; Robey, H. F.; Salmonson, J. D.; Patel, P. K.; Ma, T.; Edwards, M. J.; Stadermann, M.; Baxamusa, S.; Alford, C.; Wang, M.; Nikroo, A.; Rice, N.; Hoover, D.; Youngblood, K. P.; Xu, H.; Huang, H.; Sio, H.

    2016-05-01

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  14. Chemical inhibition of bacterial protein tyrosine phosphatase suppresses capsule production.

    Science.gov (United States)

    Standish, Alistair J; Salim, Angela A; Zhang, Hua; Capon, Robert J; Morona, Renato

    2012-01-01

    Capsule polysaccharide is a major virulence factor for a wide range of bacterial pathogens, including Streptococcus pneumoniae. The biosynthesis of Wzy-dependent capsules in both gram-negative and -positive bacteria is regulated by a system involving a protein tyrosine phosphatase (PTP) and a protein tyrosine kinase. However, how the system functions is still controversial. In Streptococcus pneumoniae, a major human pathogen, the system is present in all but 2 of the 93 serotypes found to date. In order to study this regulation further, we performed a screen to find inhibitors of the phosphatase, CpsB. This led to the observation that a recently discovered marine sponge metabolite, fascioquinol E, inhibited CpsB phosphatase activity both in vitro and in vivo at concentrations that did not affect the growth of the bacteria. This inhibition resulted in decreased capsule synthesis in D39 and Type 1 S. pneumoniae. Furthermore, concentrations of Fascioquinol E that inhibited capsule also lead to increased attachment of pneumococci to a macrophage cell line, suggesting that this compound would inhibit the virulence of the pathogen. Interestingly, this compound also inhibited the phosphatase activity of the structurally unrelated gram-negative PTP, Wzb, which belongs to separate family of protein tyrosine phosphatases. Furthermore, incubation with Klebsiella pneumoniae, which contains a homologous phosphatase, resulted in decreased capsule synthesis. Taken together, these data provide evidence that PTPs are critical for Wzy-dependent capsule production across a spectrum of bacteria, and as such represents a valuable new molecular target for the development of anti-virulence antibacterials.

  15. Chemical inhibition of bacterial protein tyrosine phosphatase suppresses capsule production.

    Directory of Open Access Journals (Sweden)

    Alistair J Standish

    Full Text Available Capsule polysaccharide is a major virulence factor for a wide range of bacterial pathogens, including Streptococcus pneumoniae. The biosynthesis of Wzy-dependent capsules in both gram-negative and -positive bacteria is regulated by a system involving a protein tyrosine phosphatase (PTP and a protein tyrosine kinase. However, how the system functions is still controversial. In Streptococcus pneumoniae, a major human pathogen, the system is present in all but 2 of the 93 serotypes found to date. In order to study this regulation further, we performed a screen to find inhibitors of the phosphatase, CpsB. This led to the observation that a recently discovered marine sponge metabolite, fascioquinol E, inhibited CpsB phosphatase activity both in vitro and in vivo at concentrations that did not affect the growth of the bacteria. This inhibition resulted in decreased capsule synthesis in D39 and Type 1 S. pneumoniae. Furthermore, concentrations of Fascioquinol E that inhibited capsule also lead to increased attachment of pneumococci to a macrophage cell line, suggesting that this compound would inhibit the virulence of the pathogen. Interestingly, this compound also inhibited the phosphatase activity of the structurally unrelated gram-negative PTP, Wzb, which belongs to separate family of protein tyrosine phosphatases. Furthermore, incubation with Klebsiella pneumoniae, which contains a homologous phosphatase, resulted in decreased capsule synthesis. Taken together, these data provide evidence that PTPs are critical for Wzy-dependent capsule production across a spectrum of bacteria, and as such represents a valuable new molecular target for the development of anti-virulence antibacterials.

  16. Effect of small bowel preparation with simethicone on capsule endoscopy

    Institute of Scientific and Technical Information of China (English)

    You-hong FANG; Chun-xiao CHEN; Bing-ling ZHANG

    2009-01-01

    Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition ofsimethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and sime-thicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intes-tines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.

  17. Characterization of the Kingella kingae polysaccharide capsule and exopolysaccharide.

    Directory of Open Access Journals (Sweden)

    Kimberly F Starr

    Full Text Available Recent evidence indicates that Kingella kingae produces a polysaccharide capsule. In an effort to determine the composition and structure of this polysaccharide capsule, in the current study we purified capsular material from the surface of K. kingae strain 269-492 variant KK01 using acidic conditions to release the capsule and a series of steps to remove DNA, RNA, and protein. Analysis of the resulting material by gas chromatography and mass spectrometry revealed N-acetyl galactosamine (GalNAc, 3-deoxy-D-manno-oct-2-ulosonic acid (Kdo, and galactose (Gal. Further analysis by NMR demonstrated two distinct polysaccharides, one consisting of GalNAc and Kdo with the structure →3-β-GalpNAc-(1→5-β-Kdop-(2→ and the other containing galactose alone with the structure →5-β-Galf-(1→. Disruption of the ctrA gene required for surface localization of the K. kingae polysaccharide capsule resulted in elimination of GalNAc and Kdo but had no effect on the presence of Gal in bacterial surface extracts. In contrast, deletion of the pamABCDE locus involved in production of a reported galactan exopolysaccharide eliminated Gal but had no effect on the presence of GalNAc and Kdo in surface extracts. Disruption of ctrA and deletion of pamABCDE resulted in a loss of all carbohydrates in surface extracts. These results establish that K. kingae strain KK01 produces a polysaccharide capsule with the structure →3-β-GalpNAc-(1→5-β-Kdop-(2→ and a separate exopolysaccharide with the structure →5-β-Galf-(1→. The polysaccharide capsule and the exopolysaccharide require distinct genetic loci for surface localization.

  18. Silicone Oil Tamponade Combined with Lensectomy Preserving Anterior Lens Capsule

    Institute of Scientific and Technical Information of China (English)

    LuL; YangJ

    1999-01-01

    Purpose:To investigate the therapeutic effect and indicatio n of silicone oil tamponade combined with lensectomy preserving anterior lens capsule.Methods:Silicone oil tamponade combined with lensectomy preserving anterior lens capsule was performed in 33 cases (33 eyes)of high myopia ,proliferative vitroretinopathy(PVR)D grade and giant retinal tear(GRT).10 cases were onlyeye and 11 cases had harder nucleus of lens.The surgical methods included:1.smashing lens nucleus and lensectomy preserving complete anterior capsule;2,vitrectomy and membrane peeling;3,usage of liquid perfluorocarbin or retinotomy or drainage;4.silicone oil tamponade;5.postoperative Nd;YAG laser for anterior capsulectomy. Results:Follow-up time was 6 months or more in 29 cases.Total retinal reattachment was achieved in 22 cases,macular retinal reattachment in 5 cases.The visual acuity was 20/800 to 20/200 in 13 cases,20/100 to 20/50 in 12 cases.Visual acuity was significantly improved in GRT group(P<0.05).Complications included unexpected anterior capsule break intraoperatively,anterior capsule opacity,silicone oil emulsification and liquid perfluorocarbin remainig postoperatively.Conclusions:Silicone oil tamponade combined with lensectomy preserving anterior capsule was safe and can reduce the operative complications.The indications included:1.GRT complicated with high myopia;2,advanced PVR cases complicated with high myopia in which silicone oil must be used;3.severe lens opacity cases in which silicone oil must be used;4.complex retinal detachment of only ye.

  19. Enzymes in the dissolution testing of gelatin capsules.

    Science.gov (United States)

    Marques, Margareth R C

    2014-12-01

    Gelatin capsules are a widely used dosage form both for pharmaceutical drug products as well as dietary supplements. Gelatin in the presence of certain compounds, mainly aldehydes, or in high humidity and high temperature conditions can cross-link. Cross-linking involves covalent bonding of the amine group of a lysine side chain of one gelatin molecule to a similar amine group on another molecule. The covalent bonding is, for practical purposes, irreversible. Cross-linking results in the formation of a pellicle on the internal or external surface of the gelatin capsule shell that prevents the capsule fill from being released. In vitro dissolution testing of cross-linked gelatin capsules can result in slower release of the drug or no release at all. The data obtained by the Gelatin Capsule Working Group, created in the early 90s to investigate noncompliance of gelatin capsules, was used to establish the type and amounts of enzymes that can be added to the dissolution medium in the case of test failure to the presence of cross-linking in the gelatin. The two-tier dissolution testing was included in the US Pharmacopeia and it recommends the addition of pepsin (pH below 6.8) or pancreatin (pH above 6.8) to the medium depending on its pH. Pepsin shows good protease activity up to pH 4 and pancreatin above pH 6 leaving a gap where neither one has good activity. Possible proteolytic enzymes that could be used for the pH range 4-6.8 could be papain or bromelain. PMID:24942315

  20. Pipeline four-dimension management is the trend of pipeline integrity management in the future

    Energy Technology Data Exchange (ETDEWEB)

    Shaohua, Dong; Feifan; Zhongchen, Han [China National Petroleum Corporation (CNPC), Beijing (China)

    2009-07-01

    Pipeline integrity management is essential for today's operators to operate their pipelines safety and cost effectively. The latest developments of pipeline integrity management around the world are involved with change of regulation, industry standard and innovation of technology. And who know the trend of PIM in the future, which can be answered in the paper. As a result, the concept of P4DM was set up firstly in the world. The paper analyzed the pipeline HSE management, pipeline integrity management (PIM) and asset integrity management (AIM), the problem of management was produced, and also the Pipeline 4-dimension Management (P4DM) theory was brought forward. According to P4DM, from the hierarchy of P4DM, the management elements, fields, space and time was analyzed. The main content is P4DM integrate the space geography location and time, control and manage the pipeline system in whole process, anywhere and anytime. It includes the pipeline integrity, pipeline operation and emergency, which is integrated by IT system. It come true that the idea, solution, technology, organization, manager alternately intelligently control the process of management. What the paper talks about included the definition of pipeline 4D management, the research develop of P4DM, the theory of P4DM, the relationship between P4DM and PIM, the technology basis of P4DM, how to perform the P4DM and conclusion. The P4DM was produced, which provide the development direction of PIM in the future, and also provide the new ideas for PetroChina in the field of technology and management. (author)

  1. Mechanism of Erhuang capsule for treatment of multiple sclerosis

    Institute of Scientific and Technical Information of China (English)

    Kangning Li; Yongping Fan; Tao Yang; Lei Wang

    2013-01-01

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation.

  2. Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    Science.gov (United States)

    Spada, C; Hassan, C; Galmiche, J P; Neuhaus, H; Dumonceau, J M; Adler, S; Epstein, O; Gay, G; Pennazio, M; Rex, D K; Benamouzig, R; de Franchis, R; Delvaux, M; Devière, J; Eliakim, R; Fraser, C; Hagenmuller, F; Herrerias, J M; Keuchel, M; Macrae, F; Munoz-Navas, M; Ponchon, T; Quintero, E; Riccioni, M E; Rondonotti, E; Marmo, R; Sung, J J; Tajiri, H; Toth, E; Triantafyllou, K; Van Gossum, A; Costamagna, G

    2012-05-01

    PillCam colon capsule endoscopy (CCE) is an innovative noninvasive, and painless ingestible capsule technique that allows exploration of the colon without the need for sedation and gas insufflation. Although it is already available in European and other countries, the clinical indications for CCE as well as the reporting and work-up of detected findings have not yet been standardized. The aim of this evidence-based and consensus-based guideline, commissioned by the European Society of Gastrointestinal Endoscopy (ESGE) is to furnish healthcare providers with a comprehensive framework for potential implementation of this technique in a clinical setting.

  3. A parametric study on ice formation inside a spherical capsule

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, K.A.R.; Silva, T.M. da [Depto. de Engenharia Termica e de Fluidos - FEM-UNICAMP CP: 6122, CEP 13083-970, SP, Campinas (Brazil); Henriquez, J.R. [Depto. de Engenharia Mecanica - DEMEC, UFPE, CEP 50740-530, PE, Recife (Brazil)

    2003-09-01

    This paper reports the results of a numerical study on the heat transfer during the process of solidification of water inside a spherical capsule. The governing equations of the problem and associated boundary conditions were formulated and solved using a finite difference approach and a moving grid scheme. The model was optimized and the numerical predictions were validated by comparison with experimental results realized by the authors. The model was also used to investigate the effects of the size and material of the shell, initial temperature of the phase change material and the external temperature of the spherical capsule on the solidified mass fraction and the time for the complete solidification. (authors)

  4. Arthroscopic Superior Capsule Reconstruction for Irreparable Rotator Cuff Tears.

    Science.gov (United States)

    Petri, Maximilian; Greenspoon, Joshua A; Millett, Peter J

    2015-12-01

    Massive irreparable rotator cuff tears in young patients are a particular challenge for the orthopaedic surgeon. Surgical treatment options include debridement, partial rotator cuff repair, patch-augmented rotator cuff repair, bridging rotator cuff reconstruction with graft interposition, tendon transfer, and reverse total shoulder arthroplasty. Recently, reconstruction of the superior glenohumeral capsule using a fascia lata autograft has been suggested to reduce superior glenohumeral translation and restore superior stability. Promising clinical results have been reported in 1 case series of 23 patients, indicating that superior capsular reconstruction may be a promising tool to manage massive irreparable rotator cuff tears. This article describes our preferred technique for arthroscopic superior capsule reconstruction. PMID:27284506

  5. A novel localization method for noninvasive monitoring capsule

    Institute of Scientific and Technical Information of China (English)

    He Wenhui; Yan Guozheng; Jiang Pingping; Guo Xudong

    2006-01-01

    Noninvasive monitoring capsule for gastrointestinal tract can be swallowed by patient. It is of great importance for the physician to monitor the precise position of capsule in gastrointestinal tract. The authors investigated a novel method for it. Using three coils with DC current to excite magnetic field and one triaxial magnetoresistive sensor to measure the excited magnetic vectors, they tried to solve the problem.The authors provided the localization principle of the method and analyzed it by an experiment, too. The method may be applied in practice in the future though it is still immature now.

  6. Preshot Predictions for Defect Induced Mix (DIME) Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, Paul A. [Los Alamos National Laboratory; Krasheninnikova, Natalia S. [Los Alamos National Laboratory; Tregillis, Ian L. [Los Alamos National Laboratory; Schmitt, Mark J. [Los Alamos National Laboratory

    2012-07-31

    In this memo, we evaluate the most probable yield and other results for the Defect Induced Mix (DIME-12A) Polar Direct Drive (PDD) capsule-only shots. We evaluate the expected yield, bang time, burn averaged ion temperature, and the average electron temperature of the Ge line-emitting region. We also include synthetic images of the capsule backlit by Cu K-{alpha} emission (8.39 keV) and core self-emission synthetic images. This memo is a companion to the maximum credible yield memo (LA-UR-12-00287) published earlier.

  7. Mechanism of Erhuang capsule for treatment of multiple sclerosis.

    Science.gov (United States)

    Li, Kangning; Fan, Yongping; Yang, Tao; Wang, Lei

    2013-02-25

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation.

  8. Mechanism of Erhuang capsule for treatment of multiple sclerosis☆

    Science.gov (United States)

    Li, Kangning; Fan, Yongping; Yang, Tao; Wang, Lei

    2013-01-01

    Erhuang capsule, a typical formula based on traditional Chinese medicine theory, is widely used to ameliorate multiple sclerosis, inflammation and side effects of glucocorticoid treatment. Oligodendrocyte precursor cells are neural stem cells that are important for myelin repair and regeneration. In the present study, Erhuang capsule effectively improved clinical symptoms and neurological function scores, reduced mortality and promoted recovery of neurological functions of mice with experimental autoimmune encephalomyelitis. The mechanism of action involved significant increases in oligodendrocyte precursor cell proliferation in specific regions of the brain and spinal cord, increased oligodendrocyte lineage gene 2 expression and enhanced oligodendrocyte precursor cell differentiation. PMID:25206695

  9. Proliferating pipelines: next growth wave gathering force

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, G.

    2001-11-05

    The fresh burst of activity in pipeline planning and construction following the buyout of Vancouver--based Westcoast Energy by Duke Energy of Charlotte, North Carolina is discussed. Although construction tapered off over the past year after the completion of the Maritime and Northern Pipeline (M and NP) and Alliance pipelines, the expansion of pipeline construction has not yet reached its peak. The scale of the Westcoast-Duke deal ($8.5 billion) underlines the extent of changes in the pipeline industry, much of which is yet to be realized. New developments described are such as Enbridge Inc's second stage in a long-range extension of the Interprovincial Pipe Line for oil from the West to Central Canada and the US Midwest to carry the projected 38 per cent increase in western oil production by 2010. In the north-eastern section of Alberta Trans Mountain Pipe Line is putting the finishing touches to its $700 million Corridor Pipeline to provide 400,000 barrels/day of additional capacity. On the Atlantic coast four new pipeline projects are lined up and a fifth is waiting in line, only two years after gas production started offshore of Nova Scotia. This includes the last missing link in the cross-Canada pipeline link. Enbridge and Montreal-based Gaz Metropolitain set a target of late 2004 for putting in service their proposed 262 km-long line to draw gas off the M and NP in New Brunswick and move its west to Quebec City for Gaz Metropolitain and to Toronto-based Enbridge Consumer Gas. In another development PanCanadian Energy signed a 10-year transportation deal with M and NP to ship 400,000 million cu ft per day from its one billion dollar Deep Panuke production development offshore of Nova Scotia. There are other developments waiting in the wings such as Houston-based Tatham Inc with its North Atlantic Pipeline Project calling a $3.2 billion, 2,200 km seafloor gas line grid to be built in stages reaching northward from the US to the Sable area and eventually to

  10. 21 CFR 876.1300 - Ingestible telemetric gastrointestinal capsule imaging system.

    Science.gov (United States)

    2010-04-01

    ... images of the small bowel with a wireless camera contained in a capsule. This device includes an ingestible capsule (containing a light source, camera, transmitter, and battery), an antenna array,...

  11. Dynamic capsule restructuring by the main pneumococcal autolysin LytA in response to the epithelium.

    Science.gov (United States)

    Kietzman, Colin C; Gao, Geli; Mann, Beth; Myers, Lance; Tuomanen, Elaine I

    2016-01-01

    Bacterial pathogens produce complex carbohydrate capsules to protect against bactericidal immune molecules. Paradoxically, the pneumococcal capsule sensitizes the bacterium to antimicrobial peptides found on epithelial surfaces. Here we show that upon interaction with antimicrobial peptides, encapsulated pneumococci survive by removing capsule from the cell surface within minutes in a process dependent on the suicidal amidase autolysin LytA. In contrast to classical bacterial autolysis, during capsule shedding, LytA promotes bacterial survival and is dispersed circumferentially around the cell. However, both autolysis and capsule shedding depend on the cell wall hydrolytic activity of LytA. Capsule shedding drastically increases invasion of epithelial cells and is the main pathway by which pneumococci reduce surface bound capsule during early acute lung infection of mice. The previously unrecognized role of LytA in removing capsule to combat antimicrobial peptides may explain why nearly all clinical isolates of pneumococci conserve this enzyme despite the lethal selective pressure of antibiotics. PMID:26924467

  12. A Cheap Levitating Gas/Load Pipeline

    CERN Document Server

    Bolonkin, Alexander

    2008-01-01

    Design of new cheap aerial pipelines, a large flexible tube deployed at high altitude, for delivery of natural (fuel) gas, water and other payload over a long distance is delineated. The main component of the natural gas is methane which has a specific weight less than air. A lift force of one cubic meter of methane equals approximately 0.5 kg (1 pound). The lightweight film flexible pipeline can be located in air at high altitude and, as such, does not damage the environment. Using the lift force of this pipeline and wing devices payloads of oil, water, or other fluids, or even solids such as coal, cargo, passengers can be delivered cheaply at long distance. This aerial pipeline dramatically decreases the cost and the time of construction relative to conventional pipelines of steel which saves energy and greatly lowers the capital cost of construction. The article contains a computed project for delivery 24 billion cubic meters of gas and tens of million tons of oil, water or other payload per year.

  13. Bauxite slurry pipeline: start up operation

    Energy Technology Data Exchange (ETDEWEB)

    Othon, Otilio; Babosa, Eder; Edvan, Francisco; Brittes, Geraldo; Melo, Gerson; Janir, Joao; Favacho, Orlando; Leao, Marcos; Farias, Obadias [Vale, Rio de Janeiro, RJ (Brazil); Goncalves, Nilton [Anglo Ferrous Brazil S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The mine of Miltonia is located in Paragominas-PA, in the north of Brazil. Bauxite slurry pipeline starts at the Mine of Miltonia and finishes in the draining installation of Alunorte refinery at the port of Barcarena-PA, located approximately 244km away from the mine. The pipeline runs over seven cities and passes below four great rivers stream beds. The system was designed for an underground 24 inches OD steel pipe to carry 9.9 million dry metric tonnes per annum (dMTAs) of 50.5% solid concentration bauxite slurry, using only one pumping station. The system is composed by four storage tanks and six piston diaphragm pumps, supplying a flow of 1680 m3/h. There is a cathodic protection system along the pipeline extension to prevent external corrosion and five pressure monitoring stations to control hydraulic conditions, there is also a fiber optic cable interconnection between pump station and terminal station. Pipeline Systems Incorporated (PSI) was the designer and followed the commissioning program of the start up operations. This paper will describe the beginning of the pipeline operations, technical aspects of the project, the operational experiences acquired in these two years, the faced problems and also the future planning. (author)

  14. Validation of pig operations through pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Tolmasquim, Sueli Tiomno [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil); Nieckele, Angela O. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica

    2005-07-01

    In the oil industry, pigging operations in pipelines have been largely applied for different purposes: pipe cleaning, inspection, liquid removal and product separation, among others. An efficient and safe pigging operation requires that a number of operational parameters, such as maximum and minimum pressures in the pipeline and pig velocity, to be well evaluated during the planning stage and maintained within stipulated limits while the operation is accomplished. With the objective of providing an efficient tool to assist in the control and design of pig operations through pipelines, a numerical code was developed, based on a finite difference scheme, which allows the simulation of two fluid transient flow, like liquid-liquid, gas-gas or liquid-gas products in the pipeline. Modules to automatically control process variables were included to employ different strategies to reach an efficient operation. Different test cases were investigated, to corroborate the robustness of the methodology. To validate the methodology, the results obtained with the code were compared with a real liquid displacement operation of a section of the OSPAR oil pipeline, belonging to PETROBRAS, with 30'' diameter and 60 km length, presenting good agreement. (author)

  15. Responding to a northern pipeline challenge

    Energy Technology Data Exchange (ETDEWEB)

    Klatt, T.J. [Alaska North Slope LNG Project, Anchorage, AK (United States)

    2000-07-01

    The challenges regarding the construction of a pipeline to transport LNG from the Alaska North Slope Liquefied Natural Gas Project were discussed. The LNG will be transported by an 800 mile buried pipeline from the Prudhoe Bay area to a liquefaction plant at an ice-free port in southern Alaska. The project is expected to begin in 2008. The isolated arctic region and permafrost add to the challenges of this project. The first challenge of synchronizing the pipeline's operating pressure with the LNG plant's inlet pressure to achieve maximum efficiencies has been addressed. Secondly, an advanced method to designing and operating a gas pipeline in discontinuous permafrost was evaluated and new construction methods were developed for trenching areas and winter construction. Stage one of the conceptual study which defines the project and minimizes costs has also been completed. More work, however, is still needed to transform the project from concept to reality. Alternative methods are still needed to construct a safe, environmentally sound and economically viable arctic gas pipeline system. 4 figs.

  16. Diagnostics and reliability of pipeline systems

    CERN Document Server

    Timashev, Sviatoslav

    2016-01-01

    The book contains solutions to fundamental problems which arise due to the logic of development of specific branches of science, which are related to pipeline safety, but mainly are subordinate to the needs of pipeline transportation.          The book deploys important but not yet solved aspects of reliability and safety assurance of pipeline systems, which are vital aspects not only for the oil and gas industry and, in general, fuel and energy industries , but also to virtually all contemporary industries and technologies. The volume will be useful to specialists and experts in the field of diagnostics/ inspection, monitoring, reliability and safety of critical infrastructures. First and foremost, it will be useful to the decision making persons —operators of different types of pipelines, pipeline diagnostics/inspection vendors, and designers of in-line –inspection (ILI) tools, industrial and ecological safety specialists, as well as to researchers and graduate students.

  17. Fiber optic accelerometer for pipeline surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Valente, Luiz C.G.; Cabral, Bruno S. [LUPATECH Monitoring Systems, Caxias do Sul, RS (Brazil); Braga, Arthur M.B. [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica

    2009-07-01

    The use of accelerometers for monitoring vibration due to impacts and other sources associated with pipeline operation is not new, but conventional electric accelerometers present practical problems to be deployed in the field. In this paper we evaluate the use of both commercially available and prototypes of new optical fiber accelerometers for this application. They all share the possibility of operating at long distances from the reading unit. All tests were performed at CTDUT facilities on free pipes as well as on a 14 pol-OD, 100 meters long pipeline loop. Using controlled impacts, several aspects of the application have been analyzed such as different ways of fixing the accelerometers to the pipeline wall, influence of barriers between impact and sensor, and signal propagation through buried sections of pipeline. Results of measurements performed during the operation of the loop are also presented. They include passing PIGs, pumping water out from the system, and working on the tubes to open the loop. Results indicate that the accelerometers can be placed at distances measuring hundreds of meters from the source of vibration, and that the difference in time and frequency behavior of signals measured by sensors placed in different locations along the pipeline may be used to locate and identify that source. (author)

  18. Hazard identification studies applied to oil pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Savio, Augusto; Alpert, Melina L. [TECNA S.A., Buenos Aires (Argentina)], e-mail: asavio@tecna.com, e-mail: malpert@tecna.com

    2008-07-01

    In order to assess risks inherent to an Oil Pipeline, it is imperative to analyze what happens 'outside the process'. HAZID (HAZard IDentification) studies are mainly carried out for this purpose. HAZID is a formal study which identifies hazards and risks associated to an operation or facility and enable its acceptability assessment. It is a brainstorming exercise guided by a typical 'Checklist', divided into four Sections: External, Facilities and Health Hazards and Issues pertaining to Project Execution, which are further subdivided into Hazard Categories. For each Category, there are 'Guide-words' and 'Prompts'. Even if an Oil Pipeline Risk Assessment can be performed by means of the above referred 'Checklist', carrying out the actual process can become lengthy and annoying due to the lack of specificity. This work aims at presenting the most suitable 'Checklist' for the identification of Oil Pipeline Risk Assessment, although it could be used for Gas Pipeline Risk Assessment too. Prepared ad hoc, this list, is based on the spill causes established by CONCAWE (CONservation of Clean Air Water in Europe). Performing Oil Pipeline Risk Assessment by means of specially formulated Checklist enables the Study Team to easily identify risks, shortens execution time and provides both accuracy and specificity. (author)

  19. JGI Plant Genomics Gene Annotation Pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Shengqiang; Rokhsar, Dan; Goodstein, David; Hayes, David; Mitros, Therese

    2014-07-14

    Plant genomes vary in size and are highly complex with a high amount of repeats, genome duplication and tandem duplication. Gene encodes a wealth of information useful in studying organism and it is critical to have high quality and stable gene annotation. Thanks to advancement of sequencing technology, many plant species genomes have been sequenced and transcriptomes are also sequenced. To use these vastly large amounts of sequence data to make gene annotation or re-annotation in a timely fashion, an automatic pipeline is needed. JGI plant genomics gene annotation pipeline, called integrated gene call (IGC), is our effort toward this aim with aid of a RNA-seq transcriptome assembly pipeline. It utilizes several gene predictors based on homolog peptides and transcript ORFs. See Methods for detail. Here we present genome annotation of JGI flagship green plants produced by this pipeline plus Arabidopsis and rice except for chlamy which is done by a third party. The genome annotations of these species and others are used in our gene family build pipeline and accessible via JGI Phytozome portal whose URL and front page snapshot are shown below.

  20. 78 FR 32010 - Pipeline Safety: Public Workshop on Integrity Verification Process

    Science.gov (United States)

    2013-05-28

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Public Workshop on Integrity Verification Process AGENCY: Pipeline and Hazardous Materials Safety Administration, DOT. ACTION: Notice of... fitness for service processes. At this workshop, the Pipeline and Hazardous Materials...

  1. 77 FR 63309 - Constitution Pipeline Company, LLC; Notice of Public Scoping Meeting and Extension of Scoping...

    Science.gov (United States)

    2012-10-16

    ... Energy Regulatory Commission Constitution Pipeline Company, LLC; Notice of Public Scoping Meeting and Extension of Scoping Period for the Planned Constitution Pipeline Project On October 24, 2012, the Federal... Constitution Pipeline Company's (Constitution) Constitution Pipeline Project. This notice also extends...

  2. Commissioning of long subsea pipelines - environmental aspects

    International Nuclear Information System (INIS)

    Discharges to air and sea are inevitable during precommissioning and commissioning of long subsea pipelines. Large quantities of water is pumped through the pipeline during these operations. This water is normally treated with corrosion inhibiting chemicals to minimise internal corrosion of the pipeline. Chemicals like methanol or glycol may be used to prevent hydrate formation, and will normally be discharged to sea during commissioning. In order to minimise the environmental impact of these operations, while maintaining corrosion protection, the Norwegian Statoil has been working for several years along three main routes such as to develop concepts and methods that minimise the discharged volumes, the use of the most environmentally friendly chemicals available, and to monitor and identify the effects of discharges to various marine species. 3 refs., 4 figs

  3. Pipelined Two-Operand Modular Adders

    Directory of Open Access Journals (Sweden)

    M. Czyzak

    2015-04-01

    Full Text Available Pipelined two-operand modular adder (TOMA is one of basic components used in digital signal processing (DSP systems that use the residue number system (RNS. Such modular adders are used in binary/residue and residue/binary converters, residue multipliers and scalers as well as within residue processing channels. The design of pipelined TOMAs is usually obtained by inserting an appriopriate number of latch layers inside a nonpipelined TOMA structure. Hence their area is also determined by the number of latches and the delay by the number of latch layers. In this paper we propose a new pipelined TOMA that is based on a new TOMA, that has the smaller area and smaller delay than other known structures. Comparisons are made using data from the very large scale of integration (VLSI standard cell library.

  4. Safety installation for preventing pollution by pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Wittgenstein, G.F.

    1972-10-25

    A safety installation for preventing pollution by pipelines, particularly those used for transporting liquid hydrocarbons, is described. It is applicable to any pipeline, but particularly to underground or submarine pipelines, whether made of steel, plastics, or any other material. The 4 essential objects of the invention are to insure reliable prevention of pollution of the environment due to leakage of a hydrocarbon through cracks in the pipe; to evacuate the leakage flow without delay to a vessel; to signal almost instantaneously the existence of a leak; and to effect remote control of operations by which the dynamic pressure in the pipe is cancelled. Each equipped section consists of a fluid-type jacket of plastic material which surrounds the pipe, which at its ends is sealed off. It is these seals which delimit the sections. (7 claims)

  5. Liquid holdup in wet-gas pipelines

    International Nuclear Information System (INIS)

    An experimental study of two-phase flow was conducted to investigate liquid holdup in wet-gas pipelines. The liquid-holdup data were obtained by passing spheres through a 1,333-ft [406.3-m] -long, 3.068-in. [77.93-mm] -ID horizontal pipe and measuring the liquid volumes removed. Three different two-phase mixtures were used. The holdup data were compared with predicted holdup values and were used to evaluate a mechanistic model for stratified flow. None of the methods could accuratly predict liquid holdup in this low-holdup region. Two new empirical liquid-holdup correlations for horizontal flow were proposed. The first is strictly for wet-gas pipelines (0< y/sub L/<0.35); the second is for any horizontal pipeline (0< y/sub L/<1.0)

  6. A New Opportunity Facing the Pipeline Sector

    Institute of Scientific and Technical Information of China (English)

    Yao Changpu

    2001-01-01

    @@ According to the State and CNPC programs for development,the nation's oil/gas pipeline sector is faced with an unprecedented historic opportunity, about to enter its golden period of development.The three major pipelines () SeNing-Lan (from Sebei of Qinghai Province to Lanzhou by way of Xining) for natural gas, LanCheng-Yu (from Lanzhou to Chengdu extending to Chongqing) for finished oils, and Zhong-Wu (from Zhongxian County of Chongqing to Wuhan)for natural gas, either under construction or planned to be constructed, have all been listed as the national priority projects of infrastructure construction. And the double-line project of the existing Shaan-Jing (Shaanxi Province to Beijing) gas pipeline has finished the procedure for establishment.

  7. Sino-Kazakh Crude Pipeline Starts Operation

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    @@ The Sino-Kazakh Crude Oil Pipeline financed by China National Petroleum Corporation (CNPC) and KazMunaiGaz, the state oil company of Kazakhstan,was launched on December 15, 2005, thanks to the commitments and endeavors of governments and constructors of both countries. The pipeline, with diameter of 813 mm, the total length of 962.2 km running from the Kazakhstan Atasu in the west to China's Alashankou in the east, with the phase I designed annual capacity up to 10 million tons. The launch of the pipeline is a milestone of the China-Kazakhstan energy cooperation, having great importance to the countries' economic growths, China's energy security strategy and the diversification of Kazakh oil exports.

  8. Corrosion fatigue properties of thermally insulated pipeline

    International Nuclear Information System (INIS)

    The corrosion fatigue properties of thermally insulated pipeline were investigated in synthetic groundwater by electrochemical test, corrosion fatigue test and SEM analysis. Since the potential difference between the weldment and the base metal was small, the pipeline steel was not susceptible to galvanic corrosion. No fatigue limit was apparent for corrosion fatigue testing with remarkable reduction of fatigue lifetime. The effects of insulation and stress on the corrosion fatigue resistance of pipeline steel were studied through Linear Polarization Resistance (LPR) and Electrochemical Impedance Spectroscopy (EIS) during corrosion fatigue testing. The result of LPR measurement indicated that the corrosion rate was determined not by the water content of PUR foam but by the magnitude of applied stress. The better corrosion fatigue property of the insulated steel was attributable to the formation of a protective rust layer under the insulation, which reduced the acceleration of corrosion process and the propagation of fatigue crack. This was confirmed by the results of EIS measurements and SEM observation

  9. Key Design Properties for Shipping Information Pipeline

    DEFF Research Database (Denmark)

    Jensen, Thomas; Tan, Yao-Hua

    2015-01-01

    on paper, e-mail, phone and text message, and far too costly. This paper explores the design properties for a shared information infrastructure to exchange information between all parties in the supply chain, commercial parties as well as authorities, which is called a Shipping Information Pipeline...... Infrastructures. The paper argues why the previous attempts are inadequate to address the issues in the domain of international supply chains. Instead, a different set of key design properties are proposed for the Shipping Information Pipeline. The solution has been developed in collaboration with a network...... of representatives for major stakeholders in international trade, whom evaluate it positively and are willing to invest, develop and test the prototype of the Shipping Information Pipeline....

  10. Engineering critical assessment of PETROBRAS Camarupim pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, J.R. [Microalloying International, Houston, TX (United States); Gatlin, R.W. [Global Industries, Rio de Janeiro, RJ (Brazil); Zumpano Junior, P.; Kaspary, T. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    This paper presents details of an Engineering Critical Assessment (ECA) performed to develop girth weld flaw acceptance criteria for the PETROBRAS Camarupim Pipeline which was installed in Espirito Santo Basin, ES, offshore Brazil in May 2008 by Global Industries. The pipeline was constructed using 24-inch diameter API Grade X65 pipe with wall thicknesses of 0.875-inch (22.2 mm) and 1.00 inch (25.4 mm). Although the Camarupim pipeline will initially transport sweet gas there is the potential for mildly sour service operation in mid to late life. To assess the effect of sour service on the material toughness properties a series of slow strain rate fracture toughness tests were performed in a Project representative sour service environment. In addition the results of sour service fatigue crack growth tests were analyzed to develop a conservative sour service fatigue crack growth law for the ECA analysis. (author)

  11. V-GAP: Viral genome assembly pipeline

    KAUST Repository

    Nakamura, Yoji

    2015-10-22

    Next-generation sequencing technologies have allowed the rapid determination of the complete genomes of many organisms. Although shotgun sequences from large genome organisms are still difficult to reconstruct perfect contigs each of which represents a full chromosome, those from small genomes have been assembled successfully into a very small number of contigs. In this study, we show that shotgun reads from phage genomes can be reconstructed into a single contig by controlling the number of read sequences used in de novo assembly. We have developed a pipeline to assemble small viral genomes with good reliability using a resampling method from shotgun data. This pipeline, named V-GAP (Viral Genome Assembly Pipeline), will contribute to the rapid genome typing of viruses, which are highly divergent, and thus will meet the increasing need for viral genome comparisons in metagenomic studies.

  12. Digitally assisted pipeline ADCs theory and implementation

    CERN Document Server

    Murmann, Boris

    2007-01-01

    List of Figures. List of Tables. Acknowledgements. Preface. 1: Introduction. 1. Motivation. 2. Overview. 3. Chapter Organization. 2: Performance Trends. 1. Introduction. 2. Digital Performance Trends. 3. ADC Performance Trends. 3: Scaling Analysis. 1. Introduction. 2. Basic Device Scaling from a Digital Perspective. 3. Technology Metrics for Analog Circuits. 4. Scaling Impact on Matching-Limited Circuits. 5. Scaling Impact on Noise-Limited Circuits. 4: Improving Analog Circuit Efficiency. 1. Introduction. 2. Analog Circuit Challenges. 3. The Cost of Feedback. 4. Two-Stage Feedback Amplifier vs. Open-Loop Gain Stage. 5. Discussion. 5: Open-Loop Pipelined ADCs. 1. A Brief Review of Pipelined ADCs. 2. Conventional Stage Implementation. 3. Open-Loop Pipeline Stages. 4. Alternative Transconductor Implementations. 6: Digital Nonlinearity Correction. 1. Overview. 2. Error Model and Digital Correction. 3. Alternative Error Models. 7: Statistics-Based Parameter Estimation. 1. Introduction. 2. Modulation Approach. 3. R...

  13. 10 CFR 32.21 - Radioactive drug: Manufacture, preparation, or transfer for commercial distribution of capsules...

    Science.gov (United States)

    2010-01-01

    ... for commercial distribution of capsules containing carbon-14 urea each for âin vivoâ diagnostic use..., preparation, or transfer for commercial distribution of capsules containing carbon-14 urea each for “in vivo... commercial distribution capsules containing 37 kBq (1 µCi) carbon-14 urea (allowing for nominal...

  14. Pipelines : one size fits all : Statoil pig inspects 42-inch and 28-inch diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Roche, P.

    2006-12-15

    This article provided details of a new multi-diameter pigging tool used to detect faulty pipelines at the Asgard oil and gas field off the Norwegian coast. The Asgard pipeline risers rest on an export riser base (ERB) which sits on the seabed and uses several valves to seal off the risers in case of leaks. Pigging of the pipelines presented a problem at the Asgard site as the first 200 metres of pipeline are 28 inches in diameter, while the remaining 707 km is 42 inches. Opting for 28 inch valves meant that the ERB could be smaller, lighter and cheaper. However, no inspection tool could cope with the huge change in diameter. A multi-diameter pig was deployed at the site in 2004. The pig was mounted on a specially designed suspension system supported by wheels. In order to find pipeline defects, the pig uses magnetic flux leakage, which magnetizes the pipe wall and magnetic field changes according to variations in wall thickness. Designed by Statoil, the tool was loaded onshore into a pig launcher, which was deployed from a sub-sea construction vessel via guide wires attached to the ERB. Using remotely controlled vehicles, the pig was launched into the pipeline as the system continued to transport gas. The operation was completed without creating hydrates in the pipeline, and no corrosion was detected during the inspection. Reductions in gas through-put were minimal during the deployment. The Asgard pigging operation involved 350 valve operations and 700 procedure steps. Besides having minimal impact on pipeline operations, the Statoil pig performed well and sustained minimal wear and tear due to its design. The multi-diameter tool has made it possible for other operators to inspect pipelines that have never been inspected before. It was concluded that Statoil is now looking for a collaborating partner that will provide the service to industry while continuing development of the technology. 6 figs.

  15. Pipeline coatings keep getting more sophisticated

    Energy Technology Data Exchange (ETDEWEB)

    Mowers, J.

    2004-08-01

    Bredero Shaw is the world's largest pipeline company. It's Canadian division, Shaw Pipe Protection Limited (SPPL), has a technology development laboratory in Calgary where a pipe coating line is being developed along with a deepwater program which tests the performance of sub-sea insulation coatings. Tests are performed at simulated service conditions of temperature, pressure and sea water environment. Research efforts have also focused on oilsands development and the challenge of keeping bitumen hot inside pipes while reducing wear caused by entrained sand. Shaw's high performance composite coating (HPCC) is a high-tech multiple component coating that is applied as a powder spray. It can withstand temperatures of -40 to -50 degrees C and is therefore particularly suited for providing mechanical, corrosion protection in large diameter transmission pipelines such as the Mackenzie Valley Gas Pipeline and the Alaska Pipeline. It is also compatible with cathodic protection. The coating consists of fusion bonded epoxy, polyolefin adhesive and a polyethylene. It has already been used for the Athabasca Pipeline which transports crude oil from Fort McMurray through Cold Lake to Hardisty, Alberta. Other developments include the Dual Powder Abrasion Coating system which consists of two fusion layers that provide damage resistance to pipelines in rocky mountainous terrain. The Yellow Jacket is a two layer coating used for oil and gas gathering systems to resist corrosion, moisture and soil stress. This paper also described other popular coatings such as the polyurethane foam coating called Insul-8 Systems; a sprayed epoxy polymer coating called Fusion Bonded Epoxy Coating; the Cement Mortar Lining; the Flow Efficiency Coating; the Concrete Weight Coating; and, the Rock Jacket corrosion coating. 1 fig.

  16. 21 CFR 520.2100 - Selenium, vitamin E capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Selenium, vitamin E capsules. 520.2100 Section 520...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.2100 Selenium, vitamin... to 1 milligram of selenium) and 56.2 milligrams of vitamin E (68 I.U.) (as d-alpha tocopheryl...

  17. 21 CFR 520.90a - Ampicillin capsules.

    Science.gov (United States)

    2010-04-01

    ... animals weighing 6 to 14 pounds, one capsule twice daily. (ii) Indications for use. Treatment of urinary...), tonsillitis due to alpha and beta hemolytic streptococci, hemolytic positive staphylococci, E. coli, and.... Treatment of respiratory tract infections (bacterial pneumonia) due to alpha and beta hemolytic...

  18. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    structure, responsive to microwave electromagnetic radiation, is attached to a first wall portion of the capsule wall structure which comprises a lossy dielectric material. At least a predetermined segment of the first wall portion is heated by received microwave electromagnetic radiation to trigger...

  19. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  20. Are Social Networking Websites Educational? Information Capsule. Volume 0909

    Science.gov (United States)

    Blazer, Christie

    2009-01-01

    More and more school districts across the country are joining social networking sites, such as Facebook and MySpace. This Information Capsule discusses the frequency with which school districts are using social networking sites, how districts are using the sites, and potential drawbacks associated with their use. Issues for districts to consider…

  1. Investigating obscure gastrointestinal bleeding : capsule endoscopy or double balloon enteroscopy?

    NARCIS (Netherlands)

    Westerhof, J.; Weersma, R. K.; Koornstra, J. J.

    2009-01-01

    The possibility to visualise the small bowel has dramatically improved with the introduction of capsule endoscopy (CE) and double balloon enteroscopy (DBE). CE and DBE have become standard practice in investigating suspected diseases of the small bowel. An important reason to perform small bowel inv

  2. Additional effective dose by patients undergoing NAI-131 capsules therapy

    Energy Technology Data Exchange (ETDEWEB)

    Orlic, M.; Jovanovic, M.; Spasic Jokic, V.; Cuknic, O.; Ilic, Z.; Vranjes Djuric, S. [VINCA - Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro (Yugoslavia)

    2006-07-01

    Capsules or solutions containing Na{sup 131}I are indicated for the therapy of some thyroid carcinomas such as functioning metastatic papillary or follicular carcinoma of the thyroid; and for the treatment of hyperthyroidism (diffuse toxic goiter and single or multiple toxic nodular goiter). The recommended dosage ranges of Na{sup 131}I capsules or solution for the therapy of the average patient (70 kg) are: (3.7-5.55) GBq for ablation of normal thyroid tissue; (3.7-7.4) GBq for subsequent treatments; a (148-370) MBq for hyperthyroidism. The purpose of this paper is to calculate effective dose as a result of iodine-131 capsules remaining in stomach before absorption starts. This result can determine the disadvantage of capsule versus solution containing sodium iodine-131 (Na{sup 131}I) in radionuclide therapy application from radiation protection point of view. The Monte Carlo code MCNP4b was used to model transport of gamma and beta particles emitted by radionuclide {sup 131}I treated as a point source at the bottom of stomach. Absorbed energy per unit transformation in stomach and surrounding organs has been calculated. (authors)

  3. PHYSIOTHERAPY INTERVENTIONS FOR ADHESIVE CAPSULITIS OF SHOULDER: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    Jacob Isaac Jason

    2015-12-01

    Full Text Available Objective: The purpose of this study was to conduct a systematic review on various physiotherapy management for adhesive capsulitis of shoulder. Methods: A search of the literature was conducted using Clinical Key, ProQuest and PEDro databases up to September 2015. Search limits included the English language and human studies. Search terms included adhesive capsulitis, frozen shoulder, Physical therapy, Physiotherapy etc. Inclusion criteria: Systematic reviews and randomised controlled trials (RCTs in English language were included if they fulfilled the following criteria: (a patients with adhesive capsulitis were included, (b results on pain and function were reported, and (c a study period of at least two weeks was reported. Articles were assessed using the Jadad (1 scale and Physiotherapy Evidence Database (PEDro scale. ‘High-quality’ was defined as a “yes” score of 50% in Jadad scale and a PEDro rating of 5 out of 10. Totally 17 studies were selected for this systematic review. Conclusion: This study has found sufficient level of evidence for physiotherapy in the treatment of adhesive capsulitis the shoulder. In particular, manual treatment must be combined with commonly indicated exercise or conventional physiotherapy, as it remains the standard care.

  4. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  5. Treatment of hyperlipoidemia by Xiaozhi capsule: a clinical efficacy research

    Institute of Scientific and Technical Information of China (English)

    王建平

    2013-01-01

    Objective To observe the clinical effect and efficacy of Xiaozhi Capsule (XZC) ,a Chinese medicine preparation for tonifying Gan-Shen,invigorating Pi to dissipate dampness (TGSIPDD) on total cholesterol (TC) ,triglyceride (TG) ,high-density lipoprotein cholesterol (HDLC) ,low-density lipoprotein cholesterol (LDL-C) ,and

  6. Research Update: Performance Pay for Teachers. Information Capsule. Volume 0911

    Science.gov (United States)

    Blazer, Christie

    2010-01-01

    Although there is a growing recognition that the traditional teacher salary schedule does not reward the most effective teachers, most U.S. school districts don't offer teacher incentives for improving student performance and the vast majority of teachers actually oppose such a plan. This Information Capsule reviewed recent studies conducted…

  7. A facile route to synthesize silver nanoparticles in polyelectrolyte capsules.

    Science.gov (United States)

    Anandhakumar, S; Raichur, Ashok M

    2011-06-01

    We are reporting a novel green approach to incorporate silver nanoparticles (NPs) selectively in the polyelectrolyte capsule shell for remote opening of polyelectrolyte capsules. This approach involves in situ reduction of silver nitrate to silver NPs using PEG as a reducing agent (polyol reduction method). These nanostructured capsules were prepared via layer by layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and dextran sulfate (DS) on silica template followed by the synthesis of silver NPs and subsequently the dissolution of the silica core. The size of silver nanoparticles synthesized was 60±20 nm which increased to 100±20 nm when the concentration of AgNO(3) increased from 25 mM to 50 mM. The incorporated silver NPs induced rupture and deformation of the capsules under laser irradiation. This method has advantages over other conventional methods involving chemical agents that are associated with cytotoxicity in biological applications such as drug delivery and catalysis. PMID:21333503

  8. 78 FR 39721 - Constitution Pipeline Company, LLC; Notice of Application

    Science.gov (United States)

    2013-07-02

    ... Energy Regulatory Commission Constitution Pipeline Company, LLC; Notice of Application Take notice that on June 13, 2013, Constitution Pipeline Company, LLC (Constitution), having its principal place of...\\ Constitution further requests that the Commission grant Constitution a blanket certificate...

  9. 76 FR 45332 - Pipeline and Hazardous Materials Safety Administration

    Science.gov (United States)

    2011-07-28

    ... Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Applications for Modification of Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration... and Hazardous Materials Safety Administration, U.S. Department of Transportation, Washington, DC...

  10. PetroChina Sees Gas Pipeline Profit in Four Years

    Institute of Scientific and Technical Information of China (English)

    Xiao Lu

    2002-01-01

    @@ Sebei-Xining- Lanzhou pipeline put into operation PetroChina, the nation's largest gas producer,recently said that the US$280-million gas pipeline in Northwest China would generate profits within four years.

  11. Progress with the LOFAR Imaging Pipeline

    CERN Document Server

    Heald, George; Pizzo, Roberto; van Diepen, Ger; van Zwieten, Joris E; van Weeren, Reinout J; Rafferty, David; van der Tol, Sebastiaan; Birzan, Laura; Shulevski, Aleksandar; Swinbank, John; Orru, Emanuela; De Gasperin, Francesco; Ker, Louise; Bonafede, Annalisa; Macario, Giulia; Ferrari, Chiara

    2010-01-01

    One of the science drivers of the new Low Frequency Array (LOFAR) is large-area surveys of the low-frequency radio sky. Realizing this goal requires automated processing of the interferometric data, such that fully calibrated images are produced by the system during survey operations. The LOFAR Imaging Pipeline is the tool intended for this purpose, and is now undergoing significant commissioning work. The pipeline is now functional as an automated processing chain. Here we present several recent LOFAR images that have been produced during the still ongoing commissioning period. These early LOFAR images are representative of some of the science goals of the commissioning team members.

  12. Multinational Gas Pipeline Hopeful on Schedule

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ The Kovykta project, which will transport natural gas from Russia's Eastern Siberia to China and Republic of Korea, might come out ahead over the Sino-Russian oil pipeline project. China and Russia are negotiating the price of the piped gas and the result of negotiations will likely be seen in three to four months, TNK-BP President and Chief Executive Officer Robert Dudley recently said,adding that he is confident that natural gas from Kovykta will start flowing through the pipeline by the end of 2008 as planned.

  13. Numerical studies on dynamic behaviour of pipelines

    International Nuclear Information System (INIS)

    Dynamic excitation due to a pipe break can cause pipe to abruptly displace and hit the components, instrumentation and equipment nearby. In order to minimize the extensive damage caused by such pipe whips in a nuclear power plant, different types of restraints and supports are designed for the pipelines. Here, structural dynamic behaviour of pipelines is studied with finite element method. A relatively short pipe line section with one bend and one restraint and rigidly fixed from its other end is chosen as a test case. The usability of different types of elements provided by Abaqus finite element code in modelling the pipe, restraint and adjacent civil structure is tested

  14. A Cheap Levitating Gas/Load Pipeline

    OpenAIRE

    Bolonkin, Alexander

    2008-01-01

    Design of new cheap aerial pipelines, a large flexible tube deployed at high altitude, for delivery of natural (fuel) gas, water and other payload over a long distance is delineated. The main component of the natural gas is methane which has a specific weight less than air. A lift force of one cubic meter of methane equals approximately 0.5 kg (1 pound). The lightweight film flexible pipeline can be located in air at high altitude and, as such, does not damage the environment. Using the lift ...

  15. Submarine Pipeline Routing Risk Quantitative Analysis

    Institute of Scientific and Technical Information of China (English)

    徐慧; 于莉; 胡云昌; 王金英

    2004-01-01

    A new method for submarine pipeline routing risk quantitative analysis was provided, and the study was developed from qualitative analysis to quantitative analysis.The characteristics of the potential risk of the submarine pipeline system were considered, and grey-mode identification theory was used. The study process was composed of three parts: establishing the indexes system of routing risk quantitative analysis, establishing the model of grey-mode identification for routing risk quantitative analysis, and establishing the standard of mode identification result. It is shown that this model can directly and concisely reflect the hazard degree of the routing through computing example, and prepares the routing selection for the future.

  16. Self lubrication of bitumen froth in pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, D.D. [Univ. of Minnesota, Minneapolis, MN (United States)

    1997-12-31

    In this paper I will review the main properties of water lubricated pipelines and explain some new features which have emerged from studies of self-lubrication of Syncrudes` bitumen froth. When heavy oils are lubricated with water, the water and oil are continuously injected into a pipeline and the water is stable when in a lubricating sheath around the oil core. In the case of bitumen froth obtained from the Alberta tar sands, the water is dispersed in the bitumen and it is liberated at the wall under shear; water injection is not necessary because the froth is self-lubricating.

  17. Noncontact optical measurement of lens capsule thickness ex vivo

    Science.gov (United States)

    Ziebarth, Noel M.; Manns, Fabrice; Uhlhorn, Stephen; Parel, Jean-Marie

    2004-07-01

    Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human, 10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9μm (human), 11.2+/-6.6μm (monkey), and 10.3+/-3.6μm (rabbit) optically and 14.9+/-1.6μm (human), 17.7+/-4.9μm (monkey), and 12.6+/-2.3μm (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9μm (human), 6.6+/-2.5μm (monkey), and 7.9+/-2.3μm (rabbit) optically and 4.6+/-1.4μm (human), 4.5+/-1.2μm (monkey), and 5.7+/-1.7μm (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.

  18. Express Crude Oil Pipeline Final Environmental Impact Statement

    OpenAIRE

    United States Department of the Interior Bureau of Land Management

    1996-01-01

    Express Pipeline, Inc. (Express) proposes to construct, maintain, and operate a 24-inch crude oil pipeline from the U.S. (Montana)/Canada border near Wild Horse to Casper, Wyoming. The project (the proposed action ) would include the 515-mile pipeline, five pump stations, numerous mainline block and check valves, and a meter station. Initially, the pipeline would be capable of transporting 172,000 barrels per day of Canadian crude oil to Casper, Wyoming. Construction is scheduled from July th...

  19. Lateral buckling and axial walking of surface laid subsea pipeline

    OpenAIRE

    Obele, Ifenna

    2013-01-01

    Subsea pipelines are increasingly being required to operate at high temperature and pressure HT/HP. The pipeline installed on the seabed and left exposed have a potential to buckle, walk and change configuration under high temperature and pressure (HT/HP). This could lead to failure of the Pipeline if buckling and walking is not properly controlled or mitigated. The objective of the thesis work is to study and understand the influence of pipeline-soil interaction on the design ...

  20. Current Status and Prospects of Oil and Gas Pipelines in China

    Institute of Scientific and Technical Information of China (English)

    Pu Ming

    2010-01-01

    @@ By the end of 2009,the total length of existing oil and gas pipelines in China had reached 75×103 km.The pipelines include 38×103 km of gas pipelines,20×103km of crude oil pipelines and 17×103 km of oil product pipelines,framing a trans-regional pipeline network for the oil and gas delivery.

  1. An ultra-low-power image compressor for capsule endoscope

    Directory of Open Access Journals (Sweden)

    Weng Ping-Kuo

    2006-02-01

    Full Text Available Abstract Background Gastrointestinal (GI endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. Methods We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. Conclusion As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.

  2. Channa striatus capsules induces cytokine conversion in pulmonary tuberculosis patients

    Directory of Open Access Journals (Sweden)

    Novita Paliliewu

    2013-06-01

    Full Text Available Objective: This study aimed to investigate whether Channa striatus capsule induces sputum and cytokine conversion in pulmonary tuberculosis (TB patients. Methods: Randomized, placebo-controlled, double-blind pilot study was conducted to pulmonary TB patients who admitted to Department of Internal Medicine, Faculty of Medicine, University of Sam Ratulangi, Manado, North Sulawesi, Indonesia. A total of 36 pulmonary TB patients were randomly divided into two equal groups (n = 18 including one group received standart antituberculosis drugs plus Channa striatus capsule and another group received standart antituberculosis drugs plus placebo. Channa striatus capsule was given at a dose of 2 g each time, 3 times per day, for 12 weeks. The levels of tumor necrosis factor (TNF-α, interferon (IFN-γ, and interleukin (IL-10 were analyses using enzyme linked immunosorbent assay (ELISA method. Results: The rate of positive sputum smear decline was more pronounced in the Channa striatus group but did not reach statistically different value between groups. The levels of TNF-α, IFN-γ, and IL-10 were not significantly different in Channa striatus group compared to placebo group at baseline (week 0. But at week 12, the supplementation of Channa striatus capsule significantly decreased TNF-α, IFN-γ, and IL-10 levels compared to baseline. In placebo groups, there were no significant differences for IL-10 levels at week 12, but the levels of TNF-α and IFN-γ significantly decreased. Conclusion: Adjunctive supplementation of Channa striatus capsules accelerated the beneficial therapeutic effect of TB chemotherapy by improving cytokine response. [J Exp Integr Med 2013; 3(3.000: 237-242

  3. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  4. Solution Based Deposition of Polyimide Ablators for NIF Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Cook, R

    2002-07-11

    Between June 1997 and March 2002 Luxel Corporation was contracted to explore the possibility of preparing NIF scale capsules with polyimide ablators using solution-based techniques. This work offered a potential alternative to a vapor deposition approach talking place at LLNL. The motivation for pursuing the solution-based approach was primarily two-fold. First, it was expected that much higher strength capsules (relative to vapor deposition) could be prepared since the solution precursors were known to produce high strength films. Second, in applying the ablator as a fluid it was expected that surface tension effects would lead to very smooth surfaces. These potential advantages were offset by expected difficulties, primary among them that the capsules would need to be levitated in some fashion (for example acoustically) during coating and processing, and that application of the coating uniformly to thicknesses of 150 pm on levitated capsules would be difficult. Because of the expected problems with the coupling of levitation and coating, most of the initial effort was to develop coating and processing techniques on stalk-mounted capsules. The program had some success. Using atomizer spray techniques in which application of {approx}5 {micro}m fluid coatings were alternated with heating to remove solvent resulted in up to 70 {micro}m thick coatings that were reasonably smooth at short wavelengths, and showed only about a 1 {micro}m thickness variation over long wavelengths. More controlled deposition with an inkjet devise was also developed. However difficult technical problems remained, and these problems coupled with the relative success of the vapor deposition approach led to the termination of the solution-based work in 2002. What follows is a compilation of the progress reports submitted by Luxel for this work which spanned a number of separate contracts. The reports are arranged chronologically, the last report in the collection has a modest summary of what

  5. Distributed acoustic sensing for pipeline monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hill, David; McEwen-King, Magnus [OptaSense, QinetiQ Ltd., London (United Kingdom)

    2009-07-01

    Optical fibre is deployed widely across the oil and gas industry. As well as being deployed regularly to provide high bandwidth telecommunications and infrastructure for SCADA it is increasingly being used to sense pressure, temperature and strain along buried pipelines, on subsea pipelines and downhole. In this paper we present results from the latest sensing capability using standard optical fibre to detect acoustic signals along the entire length of a pipeline. In Distributed Acoustic Sensing (DAS) an optical fibre is used for both sensing and telemetry. In this paper we present results from the OptaSense{sup TM} system which has been used to detect third party intervention (TPI) along buried pipelines. In a typical deployment the system is connected to an existing standard single-mode fibre, up to 50km in length, and was used to independently listen to the acoustic / seismic activity at every 10 meter interval. We will show that through the use of advanced array processing of the independent, simultaneously sampled channels it is possible to detect and locate activity within the vicinity of the pipeline and through sophisticated acoustic signal processing to obtain the acoustic signature to classify the type of activity. By combining spare fibre capacity in existing buried fibre optic cables; processing and display techniques commonly found in sonar; and state-of-the-art in fibre-optic distributed acoustic sensing, we will describe the new monitoring capabilities that are available to the pipeline operator. Without the expense of retrofitting sensors to the pipeline, this technology can provide a high performance, rapidly deployable and cost effective method of providing gapless and persistent monitoring of a pipeline. We will show how this approach can be used to detect, classify and locate activity such as; third party interference (including activity indicative of illegal hot tapping); real time tracking of pigs; and leak detection. We will also show how an

  6. Innovative Electromagnetic Sensors for Pipeline Crawlers

    Energy Technology Data Exchange (ETDEWEB)

    J. Bruce Nestleroth

    2006-05-04

    Internal inspection of pipelines is an important tool for ensuring safe and reliable delivery of fossil energy products. Current inspection systems that are propelled through the pipeline by the product flow cannot be used to inspect all pipelines because of the various physical barriers they encounter. Recent development efforts include a new generation of powered inspection platforms that crawl slowly inside a pipeline and are able to maneuver past the physical barriers that can limit inspection. At Battelle, innovative electromagnetic sensors are being designed and tested for these new pipeline crawlers. The various sensor types can be used to assess a wide range of pipeline anomalies including corrosion, mechanical damage, and cracks. Battelle is in the final year on a projected three-year development effort. In the first year, two innovative electromagnetic inspection technologies were designed and tested. Both were based on moving high-strength permanent magnets to generate inspection energy. One system involved translating permanent magnets towards the pipe. A pulse of electric current would be induced in the pipe to oppose the magnetization according to Lenz's Law. The decay of this pulse would indicate the presence of defects in the pipe wall. This inspection method is similar to pulsed eddy current inspection methods, with the fundamental difference being the manner in which the current is generated. Details of this development effort were reported in the first semiannual report on this project. The second inspection methodology is based on rotating permanent magnets. The rotating exciter unit produces strong eddy currents in the pipe wall. At distances of a pipe diameter or more from the rotating exciter, the currents flow circumferentially. These circumferential currents are deflected by pipeline defects such as corrosion and axially aligned cracks. Simple sensors are used to detect the change in current densities in the pipe wall. The second

  7. Optical fiber sensing technology in the pipeline industry

    Energy Technology Data Exchange (ETDEWEB)

    Braga, A.M.B.; Llerena, R.W.A. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica]. E-mail: abraga@mec.puc-rio.br; roberan@mec.puc-rio.br; Valente, L.C.G.; Regazzi, R.D. [Gavea Sensors, Rio de Janeiro, RJ (Brazil)]. E-mail: guedes@gaveasensors.com; regazzi@gaveasensors.com

    2003-07-01

    This paper is concerned with applications of optical fiber sensors to pipeline monitoring. The basic principles of optical fiber sensors are briefly reviewed, with particular attention to fiber Bragg grating technology. Different potential applications in the pipeline industry are discussed, and an example of a pipeline strain monitoring system based on optical fiber Bragg grating sensors is presented. (author)

  8. 18 CFR 2.57 - Temporary certificates-pipeline companies.

    Science.gov (United States)

    2010-04-01

    ...-pipeline companies. 2.57 Section 2.57 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... Policy and Interpretations Under the Natural Gas Act § 2.57 Temporary certificates—pipeline companies... the proposed construction is of major proportions. Pipeline companies are accordingly urged to...

  9. 77 FR 34458 - Pipeline Safety: Requests for Special Permit

    Science.gov (United States)

    2012-06-11

    ..., Alaska. The pipeline is intended to transport natural gas from the oil and gas producers on the Alaskan... received from Norgasco, Inc., and BreitBurn Energy Company LP, two natural gas pipeline operators, seeking... permits from two natural gas pipeline operators, Norgasco, Inc., (``NI''), and BreitBurn Energy Company...

  10. 77 FR 51848 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2012-08-27

    ... April 11, 2000 (65 FR 19477) or visit http://www.regulations.gov before submitting any such comments... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  11. 75 FR 53733 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2010-09-01

    ... Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477) or visit http... TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice...

  12. 75 FR 73160 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2010-11-29

    ... Register published on April 11, 2000 (65 FR 19477) or visit http://www.regulations.gov before submitting... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration, DOT. ACTION: Notice and request...

  13. 76 FR 33808 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2011-06-09

    ... Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477) or visit http... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  14. 75 FR 9018 - Pipeline Safety: Random Drug Testing Rate

    Science.gov (United States)

    2010-02-26

    ... percent for calendar year 2010. ] On January 19, 2010, PHMSA published an Advisory Bulletin (75 FR 2926... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice of Minimum...

  15. 75 FR 45696 - Pipeline Safety: Personal Electronic Device Related Distractions

    Science.gov (United States)

    2010-08-03

    ... Electronic Devices, 75 FR 9754, May 18, 2010; Limiting the Use of Wireless Communication Devices, 75 FR 16391... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Personal Electronic Device Related Distractions AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION:...

  16. 76 FR 45904 - Pipeline Safety: Information Collection Activities

    Science.gov (United States)

    2011-08-01

    ... complete Privacy Act Statement in the Federal Register published on April 11, 2000 (65 FR 19477) or visit... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  17. 75 FR 35516 - Pipeline Safety: Request for Special Permit

    Science.gov (United States)

    2010-06-22

    ... safety regulations in connection with the Class 1 location portion of a 7.4 mile natural gas pipeline to... regulations contained in 49 CFR 192.121, to construct and operate a dual natural gas pipeline (7.4 miles long... natural gas from the North Fork Unit and deliver it to a sales pipeline operated by Enstar Natural...

  18. 49 CFR 195.248 - Cover over buried pipeline.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Cover over buried pipeline. 195.248 Section 195.248 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION...

  19. 27 CFR 25.201 - Removal by pipeline.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Removal by pipeline. 25... Distilled Spirits Plant § 25.201 Removal by pipeline. A brewer may remove beer from the brewery, without payment of tax, by pipeline to the bonded premises of a distilled spirits plant which is authorized...

  20. Beyond the Pipeline: STEM Pathways for Youth Development

    Science.gov (United States)

    Lyon, Gabrielle H.; Jafri, Jameela; St. Louis, Kathleen

    2012-01-01

    As framed by national education policy priorities, the dominant metaphor describing participation and achievement in science, technology, engineering, and mathematics (STEM) is a "pipeline." The STEM workforce requires a "pipeline" of future scientists, engineers, and mathematicians. This pipeline begins in childhood and carries students through…

  1. 75 FR 4136 - Pipeline Safety: Requests for Special Permit

    Science.gov (United States)

    2010-01-26

    ..., 2000 (65 FR 19477). FOR FURTHER INFORMATION CONTACT: General: Kay McIver by telephone at (202) 366-0113... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Requests for Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice. SUMMARY: PHMSA...

  2. 18 CFR 284.265 - Cost recovery by interstate pipeline.

    Science.gov (United States)

    2010-04-01

    ... interstate pipeline. 284.265 Section 284.265 Conservation of Power and Water Resources FEDERAL ENERGY... § 284.265 Cost recovery by interstate pipeline. (a) Except as provided in paragraph (b), an interstate... directly assign the emergency gas costs to the recipient. (b) If an interstate pipeline cannot...

  3. Shaan-Jing Gas Transmission Pipeline

    Institute of Scientific and Technical Information of China (English)

    Deng Diqun

    1997-01-01

    @@ The gas transmission pipeline under construction from Shaan-Gan-Ning Gas Field, western China to Beijing,is of the longest transmission distance and the largest diameter of the kind so far in China. Under complex geomorphologic and geological conditions along its stretch, strict criteria are demanded for its engineering design and construction.

  4. Underwater Adhesives Retrofit Pipelines with Advanced Sensors

    Science.gov (United States)

    2015-01-01

    Houston-based Astro Technology Inc. used a partnership with Johnson Space Center to pioneer an advanced fiber-optic monitoring system for offshore oil pipelines. The company's underwater adhesives allow it to retrofit older deepwater systems in order to measure pressure, temperature, strain, and flow properties, giving energy companies crucial data in real time and significantly decreasing the risk of a catastrophe.

  5. System Reliability Assessment of Offshore Pipelines

    NARCIS (Netherlands)

    Mustaffa, Z.

    2011-01-01

    The title of this thesis, System Reliability Assessment of Offshore Pipelines, portrays the application of probabilistic methods in assessing the reliability of these structures. The main intention of this thesis is to identify, apply and judge the suitability of the probabilistic methods in evalua

  6. Surface mine blasting near pressurized transmission pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Siskind, D.E.; Stagg, M.S.; Wiegand, J.E.; Schultz, D.L.

    1994-12-31

    The US Bureau of Mines and the State of Indiana cooperated with AMAX Coal Co. and its consultants to determine the effects of coal mine overburden blasting on nearby pipelines. Five pressurized 76-m pipeline sections were installed on the Minnehaha Mine highwall near Sullivan, IN, for testing to failure. Four 17- to 51-cm-diameter welded steel pipes and one 22-cm PVC pipe were monitored for vibration, strain, and pressure for a period of 6 months while production blasting advanced up to the test pipeline field. In contrast to previous studies of small-scale, close-in blasting for construction, these tests involved overburden blasts of up to 950 kg per delay in 31-cm blastholes. Analyses found low pipe responses, strains, and calculated stresses from even large blasts. Ground vibrations of 120 to 250 mm/s produced worst case strains that were about 25 pcts of the strains resulting from normal pipeline operations and calculated stresses of only about 10 to 18 pct of the ultimate tensile strength. No pressurization failures or permanent strains occurred even at vibration amplitudes of 600 mm/s.

  7. Diversifying the Community College CEO Pipeline

    Science.gov (United States)

    Perrakis, Athena; Campbell, D. Michael; Antonaros, Mary

    2009-01-01

    The authors examine the current community college presidential pipeline and offer possible explanations for poor CEO representation from diverse populations. They explore a relationship between CEO satisfaction and diversity by testing whether CEO satisfaction is correlated to campus and administrative diversity. While data from the study…

  8. Tow techniques for marine pipeline installation

    OpenAIRE

    Fernández, M. L.

    1981-01-01

    Tow techniques for marine pipelines frequently offer competitive and commercially attactive solutions over other installation methods and, on occasion, may represent the only alternative to traditional techniques. An assessment is also made of where each tow method is applicable and technically feasible.

  9. Pipeline for Tracking Neural Progenitor Cells

    DEFF Research Database (Denmark)

    Vestergaard, Jacob Schack; Dahl, Anders Lindbjerg; Holm, Peter;

    2012-01-01

    a key role in constructing these lineages. We present here a tracking pipeline based on learning a dictionary of discriminative image patches for segmentation and a graph formulation of the cell matching problem incorporating topology changes and acknowledging the fact that segmentation errors do occur...

  10. Tow techniques for marine pipeline installation

    NARCIS (Netherlands)

    Fernández, M.L.

    1981-01-01

    Tow techniques for marine pipelines frequently offer competitive and commercially attactive solutions over other installation methods and, on occasion, may represent the only alternative to traditional techniques. An assessment is also made of where each tow method is applicable and technically feas

  11. Foreign Giants Take Gas Pipeline Stake Equally

    Institute of Scientific and Technical Information of China (English)

    Xie Ye

    2002-01-01

    @@ Oil giants Royal/Dutch, ExxonMobil and Russia's Gazprom have agreed to take 15 percent stakes each in China's US$5.6 billion natural gas pipeline project,clearing away the final obstacles blocking the kickoff of the repeatedly delayed project, according to the latest reports from news media in early July.

  12. Thermal Fatigue Analysis of Takeover Pipeline

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    This article uses the finite element analysis software ANSYS to analyze the fatigue life of the three links pipeline with different angles in the first level pipe of experimental fast reactor. The fatigue analysis is operated following the startup and shutdown process which has two load step,

  13. The Bakou-Ceyhan pipeline: paradoxes and coherence of the USA strategy of pipelines

    International Nuclear Information System (INIS)

    In 2002, the construction of the Bakou-Ceyhan pipeline, from the Caspian Sea to the Mediterranean Sea, is begun, in spite of the the controversies of industrialists against politicians and experts. The diplomatic USA activity in favor this pipeline largely contributes to the problems solution. The author presents the USA policy and strategy in the region, the economic constraints and the negotiations. (A.L.B.)

  14. Buckling and its effect on the confined flow of a model capsule suspension

    Science.gov (United States)

    Bryngelson, Spencer; Freund, Jonathan

    2015-11-01

    The rheology of confined flowing suspensions, such as blood, depend upon the dynamics of the components, which can be particularly rich when they are elastic capsules. Using boundary integral methods, we simulate a two-dimensional model channel through which flows a dense suspension of fluid-filled capsules. A parameter of principal interest is the equilibrium membrane perimeter, which ranges from round capsules to capsules with an elongated dog-bone-like equilibrium shape. It is shown that the minimum effective viscosity occurs for capsules with a biconcave equilibrium shape, similar to that of a red blood cell. The rheological behavior changes significantly over this range; transitions are linked to specific changes in the capsule dynamics. Most noteworthy is an abrupt change in behavior when capsules transition to a dog-bone-like equilibrium shape, which correlates with the onset of capsule buckling. The buckled capsules have a more varied orientation and make significant rotational (rotlet) contributions to the capsule-capsule interactions. Supported under NSF Grant No. CBET 13-36972.

  15. 78 FR 53190 - Pipeline Safety: Notice to Operators of Hazardous Liquid and Natural Gas Pipelines of a Recall on...

    Science.gov (United States)

    2013-08-28

    ... Liquid and Natural Gas Pipelines of a Recall on Leak Repair Clamps Due to Defective Seal AGENCY: Pipeline... seal. Hazardous liquid and natural gas pipeline operators should ] verify if they have any TDW LRCs... and Flanged Fittings. These LRCs were manufactured for use on hazardous liquid and natural...

  16. Economic evaluation of CO2 pipeline transport in China

    International Nuclear Information System (INIS)

    Highlights: ► We build a static hydrodynamic model of CO2 pipeline for CCS application. ► We study the impact on pressure drop of pipeline by viscosity, density and elevation. ► We point out that density has a bigger impact on pressure drop than viscosity. ► We suggest dense phase transport is preferred than supercritical state. ► We present cost-optimal pipeline diameters for different flowrates and distances. - Abstract: Carbon capture and sequestration (CCS) is an important option for CO2 mitigation and an optimized CO2 pipeline transport system is necessary for large scale CCS implementation. In the present work, a hydrodynamic model for CO2 pipeline transport was built up and the hydrodynamic performances of CO2 pipeline as well as the impacts of multiple factors on pressure drop behavior along the pipeline were studied. Based on the model, an economic model was established to optimize the CO2 pipeline transport system economically and to evaluate the unit transport cost of CO2 pipeline in China. The hydrodynamic model results show that pipe diameter, soil temperature, and pipeline elevation change have significant influence on the pressure drop behavior of CO2 in the pipeline. The design of pipeline system, including pipeline diameter and number of boosters etc., was optimized to achieve a lowest unit CO2 transport cost. In regarding to the unit cost, when the transport flow rate and distance are between 1–5 MtCO2/year and 100–500 km, respectively, the unit CO2 transport cost mainly lies between 0.1–0.6 RMB/(tCO2 km) and electricity consumption cost of the pipeline inlet compressor was found to take more than 60% of the total cost. The present work provides reference for CO2 transport pipeline design and for feasibility evaluation of potential CCS projects in China.

  17. Three-dimensional tracking of sensor capsules mobilised by fluid flow

    International Nuclear Information System (INIS)

    A new technique for simultaneously measuring particle trajectories and temperature in fluids using specially designed light-emitting sensor capsules/particles is reported. The sensor capsules each contain a microcontroller (with integrated temperature sensor), uniquely coloured light emitting diodes (LEDs), a battery, and other components. When inserted into a fluid, the sensor capsules are mobilised by fluid flow. As they emit light they can be readily tracked and their 3D position over time measured, using an externally positioned camera along with a planar mirror in a calibrated set-up. The capsules can also take intra-fluid temperature measurements and transmit encoded data by modulating their LEDs whilst moving. Controlled experiments with a sensor capsule placed on a rotating turntable and unconstrained fluid-driven motion of multiple sensor capsules placed in a mixing tank are reported. The results demonstrate how the pathlines of capsules (and instantaneous velocities) and temperature can be simultaneously measured. (paper)

  18. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  19. Diverless pipeline repair system for deep water

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Carlo M. [Eni Gas and Power, Milan (Italy); Fabbri, Sergio; Bachetta, Giuseppe [Saipem/SES, Venice (Italy)

    2009-07-01

    SiRCoS (Sistema Riparazione Condotte Sottomarine) is a diverless pipeline repair system composed of a suite of tools to perform a reliable subsea pipeline repair intervention in deep and ultra deep water which has been on the ground of the long lasting experience of Eni and Saipem in designing, laying and operating deep water pipelines. The key element of SiRCoS is a Connection System comprising two end connectors and a repair spool piece to replace a damaged pipeline section. A Repair Clamp with elastomeric seals is also available for pipe local damages. The Connection System is based on pipe cold forging process, consisting in swaging the pipe inside connectors with suitable profile, by using high pressure seawater. Three swaging operations have to be performed to replace the damaged pipe length. This technology has been developed through extensive theoretical work and laboratory testing, ending in a Type Approval by DNV over pipe sizes ranging from 20 inches to 48 inches OD. A complete SiRCoS system has been realised for the Green Stream pipeline, thoroughly tested in workshop as well as in shallow water and is now ready, in the event of an emergency situation.The key functional requirements for the system are: diverless repair intervention and fully piggability after repair. Eni owns this technology and is now available to other operators under Repair Club arrangement providing stand-by repair services carried out by Saipem Energy Services. The paper gives a description of the main features of the Repair System as well as an insight into the technological developments on pipe cold forging reliability and long term duration evaluation. (author)

  20. Energy cost reduction in oil pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Limeira, Fabio Machado; Correa, Joao Luiz Lavoura; Costa, Luciano Macedo Josino da; Silva, Jose Luiz da; Henriques, Fausto Metzger Pessanha [Petrobras Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    One of the key questions of modern society consists on the rational use of the planet's natural resources and energy. Due to the lack of energy, many companies are forced to reduce their workload, especially during peak hours, because residential demand reaches its top and there is not enough energy to fulfill the needs of all users, which affects major industries. Therefore, using energy more wisely has become a strategic issue for any company, due to the limited supply and also for the excessive cost it represents. With the objective of saving energy and reducing costs for oil pipelines, it has been identified that the increase in energy consumption is primordially related to pumping stations and also by the way many facilities are operated, that is, differently from what was originally designed. Realizing this opportunity, in order to optimize the process, this article intends to examine the possibility of gains evaluating alternatives regarding changes in the pump scheme configuration and non-use of pump stations at peak hours. Initially, an oil pipeline with potential to reduce energy costs was chosen being followed by a history analysis, in order to confirm if there was sufficient room to change the operation mode. After confirming the pipeline choice, the system is briefly described and the literature is reviewed, explaining how the energy cost is calculated and also the main characteristics of a pumping system in series and in parallel. In that sequence, technically feasible alternatives are studied in order to operate and also to negotiate the energy demand contract. Finally, costs are calculated to identify the most economical alternative, that is, for a scenario with no increase in the actual transported volume of the pipeline and for another scenario that considers an increase of about 20%. The conclusion of this study indicates that the chosen pipeline can achieve a reduction on energy costs of up to 25% without the need for investments in new

  1. Advances in riser and pipeline technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Wan C.; Mortazavi, Mehrdad; Weir, Michael S. [ExxonMobil Development Company, Dallas, TX (United States)

    2009-12-19

    As oil and gas production continues to move into new frontier areas, novel applications of the existing riser and pipeline technologies need to be developed to meet the often more stringent requirements encountered in these environments. The challenges include ultra deep water, harsh environments, aggressive fluid conditions, and local content objectives, etc. They will require industry to constantly extend, expand, and enhance the broad range of solution options. Also, the existing design criteria in industry may need to be revised or new criteria may need to be developed to satisfy these needs. Exxon Mobil (Em) employs, and works with others in industry to promote robust design and operating practices. This approach requires in-depth understanding, sound engineering principles, advanced analysis, uncertainty management, and supportive qualification test data. It enables confident selection, extrapolation, and innovation of technologies to address new riser system and pipeline challenges. Focus on fundamental is imperative to ensure integrity of the selected systems during fabrication, installation, and operation phases. Recent and past project experience in deep water Gulf of Mexico and West Africa provides many successful examples of this approach. This paper reviews several examples of the key riser system and pipeline technology enhancements recently achieved by EM to provide confidence in addressing technical and project application challenges. Riser system technology enhancements addressed in this paper include steel catenary riser (SCR) application on turret-moored FPSO with severe motions, pipe-in-pipe (PIP) hybrid production riser to effectively manage gas lift and flow assurance requirements, irregular wave analysis methodology for flexible risers and umbilicals to reduce conservatism, and qualification of riser and pipeline VIV prediction and mitigation methods. Pipeline technology enhancements detailed in this paper include lateral buckling prediction

  2. Kepler Science Operations Center Pipeline Framework

    Science.gov (United States)

    Klaus, Todd C.; McCauliff, Sean; Cote, Miles T.; Girouard, Forrest R.; Wohler, Bill; Allen, Christopher; Middour, Christopher; Caldwell, Douglas A.; Jenkins, Jon M.

    2010-01-01

    The Kepler mission is designed to continuously monitor up to 170,000 stars at a 30 minute cadence for 3.5 years searching for Earth-size planets. The data are processed at the Science Operations Center (SOC) at NASA Ames Research Center. Because of the large volume of data and the memory and CPU-intensive nature of the analysis, significant computing hardware is required. We have developed generic pipeline framework software that is used to distribute and synchronize the processing across a cluster of CPUs and to manage the resulting products. The framework is written in Java and is therefore platform-independent, and scales from a single, standalone workstation (for development and research on small data sets) to a full cluster of homogeneous or heterogeneous hardware with minimal configuration changes. A plug-in architecture provides customized control of the unit of work without the need to modify the framework itself. Distributed transaction services provide for atomic storage of pipeline products for a unit of work across a relational database and the custom Kepler DB. Generic parameter management and data accountability services are provided to record the parameter values, software versions, and other meta-data used for each pipeline execution. A graphical console allows for the configuration, execution, and monitoring of pipelines. An alert and metrics subsystem is used to monitor the health and performance of the pipeline. The framework was developed for the Kepler project based on Kepler requirements, but the framework itself is generic and could be used for a variety of applications where these features are needed.

  3. Pipeline to connect Bratislava and Vienna

    International Nuclear Information System (INIS)

    A connection will be built to connect pipeline Druzba and OMV refinery in Schwechat close to Vienna. This is the conclusion of a Memorandum of Understanding signed by Chairman of Board of Directors of OMV, Wolfgang Ruttenstorfer and the First Vice-President for Marketing in Jukos, Michail Brudno in Vienna last week. The sixty-kilometres long pipeline should be completed in 2005. First oil from western Siberia should flow into Austria in 2006. OMV signed a ten-years contract for 2 million tons of oil per year. This volume represents about 20 percent of the total capacity of the refinery in Schwechat. 'For us this is a price-effective solution. The transport will be cheaper,' said Vice-Chairman of Board of Directors of OMV, Gerhard Roiss. OMV plans to expand in the central-European region and to increase its current number of petrol-stations from the current 1.600 to 2.000 by 2008. Starting capacity of the pipeline will be 3.6 million tons that can be increased to 5 million tons. In Austria the pipeline will be operated by a new joint company where 26 percent will be controlled by OMV and 74 by Jukos or 'structures connected to Jukos'. The total investment related to connection of Druzba and the Austrian refinery should be about 28 million Euro (1.2 billion Slovak crowns). Investments in Slovakia should reach about 7.5 million Euro (314 million Slovak crowns). A major part of these cost should be covered by Jukos. The Slovak part will owned and operated by Transpetrol, a.s., Bratislava that operates and owns all the pipelines in Slovakia

  4. Emergency gas pipeline transportation with computer documentation

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-08-01

    Methods developed by the staff of the Federal Energy Regulatory Commission in cooperation with the natural gas industry to expedite the emergency transfer of natural gas are described. The majority of the United States' natural gas fields are concentrated in the south central region, comprised of Louisiana, Oklahoma, and Texas together with adjacent areas offshore in the Gulf of Mexico. This is the major source area for gas consumed in the northern, northeastern, southeastern, and far western population/industrial centers. The geographic pattern of gas flow through interstate pipelines emanates in gas producing areas and terminates in gas consuming areas. There are many other areas in the United States which produce gas but the amounts are comparatively small compared with Texas, Louisiana, and offshore Louisiana production. The various interconnections associated with a given pipeline for both receipts and deliveries are defined. The maximum volume capability in MMCFD and the volume being delivered in MMCFD are to be considered as estimated volumes. These volumes do not represent absolute volumes that are available but rather volumes for general planning purposes to define the magnitude of each interconnection. If an actual transportation route is desired, a routing may be derived from this report which then must be checked for actual volumes at a particular point in time. It is always possible that at the time of interest, there is no available capacity or deliveries.The data and information are arranged by pipeline company name followed by which companies supply gas to the named pipeline and to which companies the named pipeline delivers gas. Each receipt or delivery location is defined by the county and state.

  5. Asynchronous Complex Pipeline Design Based on ARM Instruction Set

    Institute of Scientific and Technical Information of China (English)

    WANG Bing; WANG Qin; PENG Rui-hua; FU Yu-zhuo

    2008-01-01

    This paper proposes an asynchronous complex pipeline based on ARM-V3 instruction set. Muller pipeline structure is used as prototype, and the factors which may affect pipeline performance are analyzed. To balance the difficulty of asynchronous design and performance analysis, both complete asynchronous and partial asynchronous structures aere designed and compared. Results of comparison with the well-Rnown industrial product ARM922T verify that about 30% and 40% performance improvement of the partial and complete asynchronous complex pipelines can be obtained respectively. The design methodologies can also be used in the design of other asynchronous pipelines.

  6. Zhongxian-Wuhan Pipeline Enters Substantial Construction Stage

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    @@ The pipeline from Zhongxian in Chongqing to Wuhan, the capital of Hubei Province, constructed by PetroChina Pipelines Company has entered the substantial construction stage. Reportedly, this pipeline project is divided into one trunkline and three tributary lines - the QianjiangChangsha tributary, the ZhijiangXiangfan tributary and the WuhanHuangshi tributary. The total length of the pipeline is 1400 kilometers with the designed annual transmission capacity for 3 billion cubic meters. With an investment of 5.1 billion yuan, the Zhongxian-Wuhan pipeline is most difficult for construction in China owing to the very complicated geological conditions.

  7. Protective role of the capsule and impact of serotype 4 switching on Streptococcus mitis.

    Science.gov (United States)

    Rukke, Håkon V; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S; Petersen, Fernanda C

    2014-09-01

    The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mutant showed that the capsule protected S. mitis against phagocytosis by RAW 264.7 macrophages. This effect was enhanced in the S. mitis strain expressing the S. pneumoniae capsule, which showed, in addition, increased resistance against early clearance in a mouse model of lung infection. Expression of both capsules also favored survival in human blood, and the effect was again more pronounced for the capsule-switching mutant. S. mitis survival in horse blood or in a mouse model of bacteremia was not significantly different between the wild type and the mutant strains. In all models, S. pneumoniae TIGR4 showed higher rates of survival than the S. mitis type strain or the capsule-switching mutant, except in the lung model, in which significant differences between S. pneumoniae TIGR4 and the capsule-switching mutant were not observed. Thus, we identified conditions that showed a protective function for the capsule in S. mitis. Under such conditions, S. mitis resistance to clearance could be enhanced by capsule switching to serotype 4, but it was enhanced to levels lower than those for the virulent strain S. pneumoniae TIGR4. PMID:24958712

  8. Subgouge deformations and the security of Arctic marine pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Woodworth-Lynas, C.; Nixon, D.; Phillips, R.; Palmer, A.

    1996-12-31

    Pipeline engineers have been concerned to protect underwater pipelines from ice masses, which can gouge 5 m and more below mudline. Their initial concern focused on a requirement to avoid contact between the ice and the pipeline: if the pipeline was trenched below the maximum gouging depth below mudline, the pipeline was supposed to be safe. It is now clear that this is not so. Very large deformations occur in the soil below a gouge, so that a pipeline can be damaged even if it is too deep for the ice to reach it. This has been demonstrated by the PRISE joint-industry project, which combines centrifuge modeling; analytical and finite-element studies of gouging processes and pipeline response; and field studies of relic gouges. The results give some guidance on the necessary depth of burial, which is significantly greater than the maximum gouge depth, but this is a preliminary study and further verification and research are necessary.

  9. Radiographic Determination of Flow pigs in Oil Pipelines

    International Nuclear Information System (INIS)

    Pipeline pigs are devices that are inserted into and travel throughout the length of a pipeline driven by a product flow. They are used for pipeline cleaning, pipeline protection and flow assurance in the oil, gas and other process industries. During a pigging process to clean a pipeline transporting refined petroleum oil from Buipe to Bolgatanga both in the Northern part of Ghana, the movement of the pig was obstructed leading to a blockage somewhere in the pipeline. Based on information from a pig signaler, radiographic inspections were carried on a portion of the pipeline to locate the exact position of the pig. The radiographs obtained revealed that the pig was located 50cm from a reference point and the battery component was disjointed

  10. Experimental Study on Free Spanning Submarine Pipeline Under Dynamic Excitation

    Institute of Scientific and Technical Information of China (English)

    李昕; 刘亚坤; 周晶; 马恒春; 朱彤

    2002-01-01

    Seismic load has a significant effect on the response of a free spanning submarine pipeline when the pipeline is constructed in a seismically active region. The model experiment is performed on an underwater shaking table to simulate the response of submarine pipelines under dynamic input. In consideration of the effects of the terrestrial and submarine pipeline, water depth, support condition, distance from seabed, empty and full pipeline, and span on dynamic response, 120 groups of experiments are conducted. Affecting factors are analyzed and conclnsions are drawn for reference. For the control of dynamic response, the span of a submarine pipeline is by far more important than the other factors. Meanwhile, the rosponse difference between a submarine pipeline under sine excitation and that under random excitation exists in experiments.

  11. (Northern Pipeline Agency) annual report, 1987-1988. (Administration du pipe-line du Nord) rapport annuel, 1987-1988

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    The Northern Pipeline Agency was established to facilitate the efficient and expeditious planning and construction of the Alaska Highway Gas pipeline in a manner consistent with the best interest of Canada. This report reviews the project and outlines developments that will affect operations of the pre-build and planning for second-stage construction of the pipeline. Financial statements for the Agency are also included. Major revisions in the second-stage pipeline design and substantially reduced cost estimates are outlined, which, combined with the improved market for natural gas, improve the chances for completion of the pipeline in the 1990s.

  12. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  13. A Prototype Design of a Wireless Capsule Endoscope

    Directory of Open Access Journals (Sweden)

    Y. Chan

    2006-01-01

    Full Text Available Diseases of the gastrointestinal tract, such as intestinal bleeding and ulceration, are very common. To determine the location of the disease, as well as to diagnose the problem, endoscopy is performed. A wireless capsule endoscope is a pill-sized device that is easily swallowed by the patient. It is equipped with a camera and a wireless transmitter so that as it travels through the patient's gastrointestinal tract, it takes pictures or video images of the tract and transmits the information out of the patient's body. This article discusses the possible solutions and challenges of a wireless capsule endoscope in terms of the choice of wireless frequency and circuit components. A prototype is built with commercially available components to demonstrate the concept of the device.

  14. Arthroscopic capsule reconstruction in the hip using iliotibial band allograft.

    Science.gov (United States)

    Trindade, Christiano A C; Sawyer, Gregory A; Fukui, Kiyokazu; Briggs, Karen K; Philippon, Marc J

    2015-02-01

    The hip capsule has been identified as an important static stabilizer of the hip joint. Despite the intrinsic bony stability of the hip socket, the capsule plays a key role in hip stability, particularly at the extremes of motion, and the iliofemoral ligament is the most important stabilizer in extension and external rotation. Patients who do not undergo capsular closure or plication may continue to complain of hip pain and dysfunction postoperatively, likely because of microinstability or muscle invagination into the capsular defect, and high-resolution magnetic resonance imaging or magnetic resonance arthrography will identify the capsular defect. Seen primarily in the revision setting, capsular defects can cause recurrent stress at the chondrolabral junction. An attempt at secondary closure can be challenging because of capsular limb adherence to the surrounding soft tissues. Therefore reconstruction may be the only possible surgical solution for this problem. We describe our new surgical technique for arthroscopic hip capsular reconstruction using iliotibial band allograft.

  15. Arthroscopic capsule reconstruction in the hip using iliotibial band allograft.

    Science.gov (United States)

    Trindade, Christiano A C; Sawyer, Gregory A; Fukui, Kiyokazu; Briggs, Karen K; Philippon, Marc J

    2015-02-01

    The hip capsule has been identified as an important static stabilizer of the hip joint. Despite the intrinsic bony stability of the hip socket, the capsule plays a key role in hip stability, particularly at the extremes of motion, and the iliofemoral ligament is the most important stabilizer in extension and external rotation. Patients who do not undergo capsular closure or plication may continue to complain of hip pain and dysfunction postoperatively, likely because of microinstability or muscle invagination into the capsular defect, and high-resolution magnetic resonance imaging or magnetic resonance arthrography will identify the capsular defect. Seen primarily in the revision setting, capsular defects can cause recurrent stress at the chondrolabral junction. An attempt at secondary closure can be challenging because of capsular limb adherence to the surrounding soft tissues. Therefore reconstruction may be the only possible surgical solution for this problem. We describe our new surgical technique for arthroscopic hip capsular reconstruction using iliotibial band allograft. PMID:25973378

  16. Compounding of slow-release niacinamide capsules: feasibility and characterization.

    Science.gov (United States)

    Radojkovic, Branko; Milić, Jela; Calija, Bojan

    2012-01-01

    The purpose of this study was to assess the feasibility of extemporaneous compounding of slow-release oral dosage form of niacinamide and to evaluate its release kinetics. The model formulation (preparation) was developed in the form of powder-filled hard gelatin capsules. Two slow-release preparations with different ratios of hypromellose have been prepared and evaluated in comparison with an immediate-release preparation. The dissolution tests were performed as per United States Pharmacopoeia requirements: Type I Apparatus, over 7 hours. Both slow-release preparations, containing 40% and 60% v/v hypromellose, respectively, have showed slow release kinetics. The dissolution profiles were significantly different, with similarity factor f2niacinamide capsules can be successfully compounded using hypromellose as a sole release rate modifier, and that the release mechanism is comparable to hydrophilic polymer matrix-based systems.

  17. Capsule Design for Blue Light Therapy against Helicobacter pylori.

    Science.gov (United States)

    Li, Zhangyong; Ren, Binbin; Tan, Haiyan; Liu, Shengrong; Wang, Wei; Pang, Yu; Lin, Jinzhao; Zeng, Chen

    2016-01-01

    A photo-medical capsule that emits blue light for Helicobacter pylori treatment was described in this paper. The system consists of modules for pH sensing and measuring, light-emitting diode driver circuit, radio communication and microcontroller, and power management. The system can differentiate locations by monitoring the pH values of the gastrointestinal tract, and turn on and off the blue light according to the preset range of pH values. Our experimental tests show that the capsule can operate in the effective light therapy mode for more than 32 minutes and the wireless communication module can reliably transmit the measured pH value to a receiver located outside the body. PMID:26814481

  18. [A newly-developed capsule endoscope in Japan].

    Science.gov (United States)

    Ogata, Haruhiko

    2008-07-01

    A new video capsule endoscope (VCE) developed by Olympus Medical Systems provides upgrade resolution, depth of the field, and brightness of the image, by improving the optical system, contained with the new function to adjust the level of lighting automatically coordinate with the brightness around, and the original handy displayed real-time viewer. Clinical trial using this capsule demonstrated the significantly higher diagnostic yield compared with barium contrast radiography of small bowel, especially for vascular involvement. Real-time viewer could be useful for detecting the gastric transit abnormality as well as for increasing the likelihood of a complete small-bowel examination with metoclopramide administration. Together with balloon-equipped enteroscopy, VCE is a new device which contributes to the diagnosis and the treatment of the small bowel lesion.

  19. Adhesive capsulitis of the wrist. Diagnosis and treatment.

    Science.gov (United States)

    Hanson, E C; Wood, V E; Thiel, A E; Maloney, M D; Sauser, D D

    1988-09-01

    Adhesive capsulitis occurs as a pathologic entity in the shoulder, hip, and ankle joints. Thickening and contracture of the wrist joint capsule were demonstrated on arthrograms performed on ten patients ranging in age from 20 to 82 years. The patients had pain and limited range of motion in the wrist. The findings included: (1) resistance to the injection of smaller than normal volumes of contrast material, (2) obliteration of recesses, and (3) extravasation of the contrast agent along the needle tract. Closed manipulation under general anesthesia of the wrist on four patients resulted in some improvement in range of motion. A distal ulna fracture in one older patient occurred as a complication of manipulation. Careful technique and judicious patient selection are of paramount importance.

  20. Pipeline operators training and certification using thermohydraulic simulators

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Claudio V.; Plasencia C, Jose [Pontificia Universidade Catolica (PUC-Rio), Rio de Janeiro, RJ (Brazil). Nucleo de Simulacao Termohidraulica de Dutos (SIMDUT); Montalvao, Filipe; Costa, Luciano [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The continuous pipeline operators training and certification of the TRANSPETRO's Pipeline National Operations Control Center (CNCO) is an essential task aiming the efficiency and safety of the oil and derivatives transport operations through the Brazilian pipeline network. For this objective, a hydraulic simulator is considered an excellent tool that allows the creation of different operational scenarios for training the pipeline hydraulic behavior as well as for testing the operator's responses to normal and abnormal real time operational conditions. The hydraulic simulator is developed based on a pipeline simulation software that supplies the hydraulic responses normally acquired from the pipeline remote units in the field. The pipeline simulation software has a communication interface system that sends and receives data to the SCADA supervisory system database. Using the SCADA graphical interface to create and to customize human machine interfaces (HMI) from which the operator/instructor has total control of the pipeline/system and instrumentation by sending commands. Therefore, it is possible to have realistic training outside of the real production systems, while acquiring experience during training hours with the operation of a real pipeline. A pilot Project was initiated at TRANSPETRO - CNCO targeting to evaluate the hydraulic simulators advantages in pipeline operators training and certification programs. The first part of the project was the development of three simulators for different pipelines. The excellent results permitted the project expansion for a total of twenty different pipelines, being implemented in training programs for pipelines presently operated by CNCO as well as for the new ones that are being migrated. The main objective of this paper is to present an overview of the implementation process and the development of a training environment through a pipe simulation environment using commercial software. This paper also presents

  1. Adhesive capsulitis and dynamic splinting: a controlled, cohort study

    OpenAIRE

    Willis F Buck; Gaspar Paul D

    2009-01-01

    Abstract Background Adhesive Capsulitis (AC) affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in contracture reduction from pathologies including Trismus to plantar fasciitis. The purpose of this study was to examine the efficacy of dynamic splinting on patients with AC. Methods This controlled, cohort study, was conducted at four physical therapy, sports medicine clinics in Texas and California. Sixty...

  2. Small bowel capsule endoscopy in 2007: Indications, risks and limitations

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Capsule endoscopy has revoluzionized the study of the small bowel by providing a reliable method to evaluate,endoscopically, the entire small bowel. In the last six years several papers have been published exploring the possible role of this examination in different clinical conditions. At the present time capsule endoscopy is generally recommended as a third examination, after negative bidirectional endoscopy, in patients with obscure gastrointestinal bleeding. A growing body of evidence suggests also an important role for this examination in other clinical conditions such as Crohn's disease, celiac disease, small bowel polyposis syndromes or small bowel tumors. The main complication of this examination is the retention of the device at the site of a previously unknown small bowel stricture. However there are also some other open issues mainly due to technical limitations of this tool (which is not driven from remote control, is unable to take biopsies, to insufflate air, to suck fluids or debris and sometimes to correctly size and locate lesions).The recently developed double balloon enteroscope, owing to its capability to explore a large part of the small bowel and to take targeted biopsies, although being invasive and time consuming,can overcome some limitations of capsule endoscopy.At the present time, in the majority of clinical conditions (i.e. obscure GI bleeding), the winning strategy seems to be to couple these two techniques to explore the small bowel in a painless, safe and complete way (with capsule endoscopy) and to define and treat the lesions identified (with double balloon enteroscopy).

  3. Acetylene bubble-powered autonomous capsules: towards in situ fuel.

    Science.gov (United States)

    Moo, James Guo Sheng; Wang, Hong; Pumera, Martin

    2014-12-28

    A fuel-free autonomous self-propelled motor is illustrated. The motor is powered by the chemistry of calcium carbide and utilising water as a co-reactant, through a polymer encapsulation strategy. Expulsion of acetylene bubbles powers the capsule motor. This is an important step, going beyond the toxic hydrogen peroxide fuel used normally, to find alternative propellants for self-propelled machines.

  4. Improved, Low-Stress Economical Submerged Pipeline

    Science.gov (United States)

    Jones, Jack A.; Chao, Yi

    2011-01-01

    A preliminary study has shown that the use of a high-strength composite fiber cloth material may greatly reduce fabrication and deployment costs of a subsea offshore pipeline. The problem is to develop an inexpensive submerged pipeline that can safely and economically transport large quantities of fresh water, oil, and natural gas underwater for long distances. Above-water pipelines are often not feasible due to safety, cost, and environmental problems, and present, fixed-wall, submerged pipelines are often very expensive. The solution is to have a submerged, compliant-walled tube that when filled, is lighter than the surrounding medium. Some examples include compliant tubes for transporting fresh water under the ocean, for transporting crude oil underneath salt or fresh water, and for transporting high-pressure natural gas from offshore to onshore. In each case, the fluid transported is lighter than its surrounding fluid, and thus the flexible tube will tend to float. The tube should be ballasted to the ocean floor so as to limit the motion of the tube in the horizontal and vertical directions. The tube should be placed below 100-m depth to minimize biofouling and turbulence from surface storms. The tube may also have periodic pumps to maintain flow without over-pressurizing, or it can have a single pump at the beginning. The tube may have periodic valves that allow sections of the tube to be repaired or maintained. Some examples of tube materials that may be particularly suited for these applications are non-porous composite tubes made of high-performance fibers such as Kevlar, Spectra, PBO, Aramid, carbon fibers, or high-strength glass. Above-ground pipes for transporting water, oil, and natural gas have typically been fabricated from fiber-reinforced plastic or from more costly high-strength steel. Also, previous suggested subsea pipeline designs have only included heavy fixed-wall pipes that can be very expensive initially, and can be difficult and expensive

  5. Inflated Sporopollenin Exine Capsules Obtained from Thin-Walled Pollen

    Science.gov (United States)

    Park, Jae Hyeon; Seo, Jeongeun; Jackman, Joshua A.; Cho, Nam-Joon

    2016-06-01

    Sporopollenin is a physically robust and chemically resilient biopolymer that comprises the outermost layer of pollen walls and is the first line of defense against harsh environmental conditions. The unique physicochemical properties of sporopollenin increasingly motivate the extraction of sporopollenin exine capsules (SECs) from pollen walls as a renewable source of organic microcapsules for encapsulation applications. Despite the wide range of different pollen species with varying sizes and wall thicknesses, faithful extraction of pollen-mimetic SECs has been limited to thick-walled pollen capsules with rigid mechanical properties. There is an unmet need to develop methods for producing SECs from thin-walled pollen capsules which constitute a large fraction of all pollen species and have attractive materials properties such as greater aerosol dispersion. Herein, we report the first successful extraction of inflated SEC microcapsules from a thin-walled pollen species (Zea mays), thereby overcoming traditional challenges with mechanical stability and loss of microstructure. Morphological and compositional characterization of the SECs obtained by the newly developed extraction protocol confirms successful protein removal along with preservation of nanoscale architectural features. Looking forward, there is excellent potential to apply similar strategies across a wide range of unexplored thin-walled pollen species.

  6. Adhesive capsulitis and dynamic splinting: a controlled, cohort study

    Directory of Open Access Journals (Sweden)

    Willis F Buck

    2009-09-01

    Full Text Available Abstract Background Adhesive Capsulitis (AC affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in contracture reduction from pathologies including Trismus to plantar fasciitis. The purpose of this study was to examine the efficacy of dynamic splinting on patients with AC. Methods This controlled, cohort study, was conducted at four physical therapy, sports medicine clinics in Texas and California. Sixty-two patients diagnosed with Stage II Adhesive Capsulitis were grouped by intervention. The intervention categories were as follows: Group I (Control; Group II (Physical Therapy exclusively with standardized protocols; Group III; (Shoulder Dynasplint system exclusively; Group IV (Combined treatment with Shoulder Dynasplint and standardized Physical Therapy. The duration of this study was 90 days for all groups, and the main outcome measures were change in active, external rotation. Results Significant difference was found for all treatment groups (p Conclusion The difference for the combined treatment group was attributed to patients' receiving the best PT combined with structured "home therapy" that contributed an additional 90 hours of end-range stretching. This adjunct should be included in the standard of care for adhesive Capsulitis. Trial Registration Trial Number: NCT00873158

  7. Mission Capture with a Multi-Role Capsule

    Science.gov (United States)

    Hempsell, M.

    The multi-role system concept is to maximise the number of mission that a system can undertake, thus maximising the value of its acquisition cost. The viability of this concept was explored by matching missions from International Space Station (ISS) support through to to Mars Landing with a feasibility design for a multi-role capsule. It was found that as the missions became more ambitious and moved further from lunar/Earth space, so increasing large add-on modules were required. However, these modules contained only simple elements like propellant tanks, increased pressurised space and supplies, and therefore represented lower cost developments; the expensive functions having been undertaken by the capsule. When it came to human interplanetary missions such as to Mars it was found that new primary transportation systems were required, but the capsule could still play a key role in support, for example Mars lander ascent stage, conducting Martian moon excursion missions and as the crew return to earth system. Given the immediate future of manned space flight is to maintain ISS operations combined with a range of exploration objectives beyond earth orbit, it is clearly not viable to develop specialist systems for each mission and multi-role systems will be essential. The feasibility concept illustrated how systems that require heavy development investment can made with sufficiently flexible to cover all these missions with only minimal additional investments.

  8. Investigation of fMRI activation in the internal capsule

    Directory of Open Access Journals (Sweden)

    Brewer Kimberley D

    2011-06-01

    Full Text Available Abstract Background Functional magnetic resonance imaging (fMRI in white matter has long been considered controversial. Recently, this viewpoint has been challenged by an emerging body of evidence demonstrating white matter activation in the corpus callosum. The current study aimed to determine whether white matter activation could be detected outside of the corpus callosum, in the internal capsule. Data were acquired from a 4 T MRI using a specialized asymmetric spin echo spiral sequence. A motor task was selected to elicit activation in the posterior limb of the internal capsule. Results White matter fMRI activation was examined at the individual and group levels. Analyses revealed that activation was present in the posterior limb of the internal capsule in 80% of participants. These results provide further support for white matter fMRI activation. Conclusions The ability to visualize functionally active tracts has strong implications for the basic scientific study of connectivity and the clinical assessment of white matter disease.

  9. Controllable light capsules employing modified Bessel-Gauss beams.

    Science.gov (United States)

    Gong, Lei; Liu, Weiwei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new route for generating and controlling bottle beams and will widen the potentials for micromanipulation of absorbing particles, aerosols or even individual atoms. PMID:27388558

  10. Little Joe (LJ1A): Only true Boilerplate capsule

    Science.gov (United States)

    1959-01-01

    The Mercury capsule and escape tower are being lowered onto the Little Joe booster for launch on August 21, 1959. Joseph Shortal described this as follows (vol. 3, p. 33): 'The Little Joe booster was assembled at Wallops on its special launcher in a vertical attitude. It is shown in the [on the left] with the work platform in place. The launcher was located on a special concrete slab in Launching Area 1. The capsule was lowered onto the booster by crane.... After the assembly was completed, the scaffolding was disassembled and the launcher pitched over to its normal launch angle of 80 degrees.... Little Joe had a diameter of 80 inches and an overall length, including the capsule and escape tower of 48 feet. The total weight at launch was about 43,000 pounds. The overall span of the stabilizing fins was 21.3 feet.' 'Although in comparison with the overall Mercury Project, Little Joe was a simple undertaking, the fact that an attempt was made to condense a normal two-year project into a 6-month one with in house labor turned it into a major undertaking for Langley.' - Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.

  11. Lateral migration of a capsule in a parabolic flow.

    Science.gov (United States)

    Nix, S; Imai, Y; Ishikawa, T

    2016-07-26

    Red blood cells migrate to the center of the blood vessel in a process called axial migration, while other blood cells, such as white blood cells and platelets, are disproportionately found near the blood vessel wall. However, much is still unknown concerning the lateral migration of cells in the blood; the specific effect of hydrodynamic factors such as a wall or a shear gradient is still unclear. In this study, we investigate the lateral migration of a capsule using the boundary integral method, in order to compute exactly an infinite computational domain for an unbounded parabolic flow and a semi-infinite computational domain for a near-wall parabolic flow in the limit of Stokes flow. We show that the capsule lift velocity in an unbounded parabolic flow is linear with respect to the shear gradient, while the lift velocity in a near-wall parabolic flow is dependent on the distance to the wall. Then, using these relations, we give an estimation of the relative effect of the shear gradient as a function of channel width and distance between the capsule and the wall. This estimation can be used to determine cases in which the effect of the shear gradient or wall can be neglected; for example, the formation of the cell-free layer in blood vessels is determined to be unaffected by the magnitude of the shear gradient.

  12. High-Density Carbon (HDC) Ablator for NIC Ignition Capsules

    Science.gov (United States)

    Ho, D.; Haan, S.; Salmonson, J.; Milovich, J.; Callahan, D.

    2012-10-01

    HDC ablators show high performance based on simulations, despite the fact that the shorter pulses for HDC capsules result in higher M-band radiation compared to that for plastic capsules. HDC capsules have good 1-D performance because HDC has relatively high density (3.5 g/cc), which results in a thinner ablator that absorbs more radiation. HDC ablators have good 2-D performance because the ablator surface is more than an order-of-magnitude smoother than Be or plastic ablators. Refreeze of the ablator near the fuel region can be avoided by appropriate dopant placement. Here we present two HDC ignition designs doped with W and Si. For the design with maximum W concentration of 1.0 at% (and respectively with maximum Si concentration of 2.0 at%): peak velocity = 0.395 (0.397) mm/ns, mass weighted fuel entropy = 0.463 (0.469) kJ/mg/eV, peak core hydrodynamic stagnation pressure = 690 (780) Gbar, and yield = 17.3 (20.2) MJ. 2-D simulations show that yield is close to 80% YoC even with 2.5x of nominal surface roughness on all surfaces. The clean fuel fraction is about 75% at peak velocity. Doping HDC with the required concentration of W and Si is in progress. A first undoped HDC Symcap is scheduled to be fielded later this year.

  13. Design and fabrication of HFIR-MFE RB* spectrally tailored irradiation capsules

    International Nuclear Information System (INIS)

    Design and fabrication of four High Flux Isotope Reactor-magnetic fusion energy removable beryllium capsules (60, 200, 330, and 400/C) to accommodate magnetic fusion energy specimens preirradiated in spectrally tailored experiments in the ORR are proceeding satisfactorily. These capsule designs incorporate provisions for removal, examination, and re-encapsulation of the MFE specimens at intermediate exposure levels en route to a target exposure level of 30 displacements per atom (dpa). With the exception of the 600C capsule, where the test specimens will be in direct contact with the reactor cooling water, the specimen temperatures (monitored by 21 thermocouples) will be controlled by varying the thermal conductance of a small gap region between the specimen holder and the containment tube. Hafnium sleeves will be used to tailor the neutron spectrum to closely match the helium production-to-atom displacement ratio (14 appm/dpa) expected in a fusion reactor first wall. Design and preparation of fabrication drawing for the 60 and 3300C capsules and all generic capsule components and support facilities have now been completed. Assembly of the 600C capsule is complete and the 3300C capsule is nearing completion. The irradiation of both capsules will begin when the HFIR returns to full power operation. Design and preparation of fabrication drawings for the 200 and 4000C capsules will be completed in 1988, and operation of these two capsules will follow the first two (60 and 3300C). 5 references, 3 figures, 1 table

  14. Comparison of esophageal capsule endoscopy and esophagogastroduodenoscopy for diagnosis of esophageal varices

    Institute of Scientific and Technical Information of China (English)

    Catherine T Frenette; John G Kuldau; Donald J Hillebrand; Jill Lane; Paul J Pockros

    2008-01-01

    AIM: To investigate the utility of esophageal capsule endoscopy in the diagnosis and grading of esophageal varices.METHODS: Cirrhotic patients who were undergo-ing esophagogastroduodenoscopy (EGD) for variceal screening or surveillance underwent capsule endos-copy. Two separate blinded investigators read each capsule endoscopy for the following results: variceal grade, need for treatment with variceal banding or prophylaxis with beta-blocker therapy, degree of portal hypertensive gastropathy, and gastric varices.RESULTS: Fifty patients underwent both capsule and EGD. Forty-eight patients had both procedures on the same day, and 2 patients had capsule endoscopy within 72 h of EGD. The accuracy of capsule endos-copy to decide on the need for prophylaxis was 74%,with sensitivity of 63% and specificity of 82%. Inter-rater agreement was moderate (kappa = 0.56). Agree-ment between EGD and capsule endoscopy on grade of varices was 0.53 (moderate). Inter-rater reliability was good (kappa = 0.77). In diagnosis of portal hyper.tensive gastropathy, accuracy was 57%, with sensitiv-ity of 96% and specificity of 17%. Two patients had gastric varices seen on EGD, one of which was seen on capsule endoscopy. There were no complications from capsule endoscopy.CONCLUSION: We conclude that capsule endoscopy has a limited role in deciding which patients would benefit from EGD with banding or beta-blocker thera-py. More data is needed to assess accuracy for staging esophageal varices, PHG, and the detection of gastric varices.

  15. Comparative performance of capsulated Vs non-capsulated 14C-urea breath test for the detection of Helicobacter pylori infection

    International Nuclear Information System (INIS)

    Conventionally, 14C-urea breath test (14C-UBT) is employed as a 'gold standard' technique for the detection of active Helicobacter pylori (H pylori) infection, to follow up the patients after its eradication and for epidemiological evaluations. Due to high accuracy of this test and other benefits it is recommended as the best option for 'test-and-treat' strategy in primary health care centers. So far no appropriate study has been done to compare the performance of 14C-UBT using capsulated versus non-capsulated protocol. In this study, we employed a novel technique of performing capsulated 14C-UBT with simultaneous monitoring the dynamic movement of capsule and compared the results with non-capsulated protocol. (author)

  16. Hexameric Capsules Studied by Magic Angle Spinning Solid-State NMR Spectroscopy: Identifying Solvent Molecules in Pyrogallol[4]arene Capsules.

    Science.gov (United States)

    Avram, Liat; Goldbourt, Amir; Cohen, Yoram

    2016-01-18

    Powders of pyrogallol[4]arene hexamers were produced by evaporation from organic solvents and were studied, for the first time, by magic angle spinning solid-state NMR (MAS ssNMR). Evaporation selectively removed non-encapsulated solvent molecules leaving stable hexameric capsules encapsulating solvent molecules. After exposure of the powder to solvent vapors, (1)H/(13)C heteronuclear correlation MAS ssNMR experiments were used to assign the signals of the external and encapsulated solvent molecules. The formed capsules were stable for months and the process of solvent encapsulation was reversible. According to the ssNMR experiments, the encapsulated solvent molecules occupy different sites and those sites differ in their mobility. The presented approach paves the way for studying guest exchange, guest affinity, and gas storage in hexamers of this type in the solid state.

  17. The e-MERLIN Data Reduction Pipeline

    Directory of Open Access Journals (Sweden)

    Megan Kirsty Argo

    2015-01-01

    Full Text Available Written in Python and utilising ParselTongue to interface with the Astronomical Image Processing System (AIPS, the e-MERLIN data reduction pipeline is intended to automate the procedures required in processing and calibrating radio astronomy data from the e-MERLIN correlator. Driven by a plain text file of input parameters, the pipeline is modular and can be run in stages by the user, depending on requirements. The software includes options to load raw data, average in time and/or frequency, flag known sources of interference, flag more comprehensively with SERPent, carry out some or all of the calibration procedures (including self-calibration, and image in either normal or wide-field mode. It also optionally produces a number of useful diagnostic plots at various stages so that the quality of the data can be assessed. The software is available for download from the e-MERLIN website or via Github.

  18. Automatic pipeline operation using Petri Nets

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Guilherme O. [PETROBRAS TRANSPORTE S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    A pipeline operation requires several actions, attention and time from the control room operator in each of its operating phases. This article proposition is to use automation as something more than a remote control, drastically reducing the number of repetitive and routine actions needed from the operator to start and stop the system, granting more time for system supervision, decision making during critical conditions and avoiding errors caused due to the need of several actions being executed in a short period of time. To achieve these objectives the pipeline operation will be modeled as a Petri Net consisting of states, event and actions. A methodology for converting this Petri Net into a Ladder controller code will also be proposed. (author)

  19. Pipelines, utilities plan over 150 scada systems

    International Nuclear Information System (INIS)

    This paper reports that North American pipelines and utilities will spend more than $170 million on new or upgraded supervisory control and data acquisition (scada) systems during the 30-month period that commenced Sept. 1. Another $12.5 million will be spent on peripherals and consulting. Among the 699 various projects to be implemented during the period, companies will install 151 scada systems, add 154 remote-terminal units (RTUs) to existing scada units, and install 196 communications systems. Scada systems are computerized hardware and software systems that perform a set of monitoring and control functions. In gas utilities, these systems perform functions normally associated with gas transmission and distribution as well as production plant process control. In gas and oil pipelines, the systems perform these functions as well as such specialized functions as batch tracking, leak detection, and gas load flow

  20. Microwave Radar Detection of Gas Pipeline Leaks

    Science.gov (United States)

    Gopalsami, N.; Kanareykin, D. B.; Asanov, V.; Bakhtiari, S.; Raptis, A. C.

    2003-03-01

    We are developing a microwave radar sensing and imaging system to detect and locate gas leaks in natural gas pipelines. The underlying detection principle is radar backscattering from the index-of-refraction inhomogeneities introduced by the dispersion of methane in air. An essential first step in the development effort is modeling to estimate the radar cross section. This paper describes the modeling results and the experimental efforts underway to validate the model. For the case of leaks from small holes in a pressurized gas pipeline, we modeled the gas dynamics of the leak jet to determine the plume geometry and the variation of methane concentration in air as a function of distance from the leak source. From the static and dynamic changes in the index of refraction in the turbulent plume, the radar backscatter cross sections were calculated. The results show that the radar cross sections of the leak plumes should be detectable by special-purpose radars.

  1. Leadership pipeline i den offentlige sektor

    DEFF Research Database (Denmark)

    Dahl, Kristian Aagaard; Molly-Søholm, Thorkil

    enkelte lederniveauer og udvikle ledertalenter. Teorien byder på et detaljeret ledelsesgrundlag, hvorudfra den offentlige organisation kan bygge en professionel værdikæde for ledelse ved at forme lederprofiler, -rekruttering, -uddannelse, -evaluering m.m. Leadership Pipeline i den offentlige sektor er......en rejse ind i hjertet af offentlig ledelse med fokus på lederniveauerne: topchef, funktionel chef, leder af ledere og leder af medarbejdere. Med afsæt i righoldige eksempler og fortællinger fra virkeligheden introduceres læseren for ledelsesteorien den Offentlige Leadership Pipeline, som giver...... unik indsigt i: - hvad der kendetegner offentlige ledere, der lykkes - og ledere, der får fiasko - hvilke mekanismer, der får lederkarrieren til at køre af sporet - og hvilke, der får karrieren til at tage fart - hvordan den offentlige organisation bedst muligt kan understøtte den rette ledelse på de...

  2. Sensor network architectures for monitoring underwater pipelines.

    Science.gov (United States)

    Mohamed, Nader; Jawhar, Imad; Al-Jaroodi, Jameela; Zhang, Liren

    2011-01-01

    This paper develops and compares different sensor network architecture designs that can be used for monitoring underwater pipeline infrastructures. These architectures are underwater wired sensor networks, underwater acoustic wireless sensor networks, RF (radio frequency) wireless sensor networks, integrated wired/acoustic wireless sensor networks, and integrated wired/RF wireless sensor networks. The paper also discusses the reliability challenges and enhancement approaches for these network architectures. The reliability evaluation, characteristics, advantages, and disadvantages among these architectures are discussed and compared. Three reliability factors are used for the discussion and comparison: the network connectivity, the continuity of power supply for the network, and the physical network security. In addition, the paper also develops and evaluates a hierarchical sensor network framework for underwater pipeline monitoring.

  3. Sensor Network Architectures for Monitoring Underwater Pipelines

    Directory of Open Access Journals (Sweden)

    Imad Jawhar

    2011-11-01

    Full Text Available This paper develops and compares different sensor network architecture designs that can be used for monitoring underwater pipeline infrastructures. These architectures are underwater wired sensor networks, underwater acoustic wireless sensor networks, RF (Radio Frequency wireless sensor networks, integrated wired/acoustic wireless sensor networks, and integrated wired/RF wireless sensor networks. The paper also discusses the reliability challenges and enhancement approaches for these network architectures. The reliability evaluation, characteristics, advantages, and disadvantages among these architectures are discussed and compared. Three reliability factors are used for the discussion and comparison: the network connectivity, the continuity of power supply for the network, and the physical network security. In addition, the paper also develops and evaluates a hierarchical sensor network framework for underwater pipeline monitoring.

  4. e-MERLIN data reduction pipeline

    Science.gov (United States)

    Argo, Megan

    2014-07-01

    Written in Python and utilizing ParselTongue (ascl:1208.020) to interface with AIPS (ascl:9911.003), the e-MERLIN data reduction pipeline processes, calibrates and images data from the UK's radio interferometric array (Multi-Element Remote-Linked Interferometer Network). Driven by a plain text input file, the pipeline is modular and can be run in stages. The software includes options to load raw data, average in time and/or frequency, flag known sources of interference, flag more comprehensively with SERPent (ascl:1312.001), carry out some or all of the calibration procedures (including self-calibration), and image in either normal or wide-field mode. It also optionally produces a number of useful diagnostic plots at various stages so data quality can be assessed.

  5. The e-MERLIN Data Reduction Pipeline

    CERN Document Server

    Argo, Megan

    2015-01-01

    Written in Python and utilising ParselTongue to interface with the Astronomical Image Processing System (AIPS), the e-MERLIN data reduction pipeline is intended to automate the procedures required in processing and calibrating radio astronomy data from the e-MERLIN correlator. Driven by a plain text file of input parameters, the pipeline is modular and can be run in stages by the user, depending on requirements. The software includes options to load raw data, average in time and/or frequency, flag known sources of interference, flag more comprehensively with SERPent, carry out some or all of the calibration procedures including self-calibration), and image in either normal or wide-field mode. It also optionally produces a number of useful diagnostic plots at various stages so that the quality of the data can be assessed. The software is available for download from the e-MERLIN website or via Github.

  6. Development of an automatic pipeline scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae H.; Lee, Jae C.; Moon, Soon S.; Eom, Heung S.; Choi, Yu R

    1999-11-01

    Pressure pipe inspection in nuclear power plants is one of the mandatory regulation items. Comparing to manual ultrasonic inspection, automatic inspection has the benefits of more accurate and reliable inspection results and reduction of radiation disposal. final object of this project is to develop an automatic pipeline inspection system of pressure pipe welds in nuclear power plants. We developed a pipeline scanning robot with four magnetic wheels and 2-axis manipulator for controlling ultrasonic transducers, and developed the robot control computer which controls the robot to navigate along inspection path exactly. We expect our system can contribute to reduction of inspection time, performance enhancement, and effective management of inspection results. The system developed by this project can be practically used for inspection works after field tests. (author)

  7. Pipelines explosion, violates Humanitarian International Right

    International Nuclear Information System (INIS)

    Recently and for first time, an organism of the orbit of the human rights put the finger in the wound of the problem that represents for Colombia the pipelines explosion and the social and environmental impact that those actions in this case the Defense of the People office, the institution that published a document related this denounces, in the one that sustains that the country it cannot continue of back with a serious and evident reality as the related with the explosions of pipelines. We are the only country of the world where happen these facts and enormous losses are not only causing to the Colombian economy, but rather our environmental wealth is affecting, the document, denounced the ignorance of the humanitarian international right on the part of those who apply to that class of attacks

  8. The MUSE Data Reduction Software Pipeline

    Science.gov (United States)

    Weilbacher, P. M.; Roth, M. M.; Pécontal-Rousset, A.; Bacon, R.; Muse Team

    2006-07-01

    After giving a short overview of the instrument characteristics of the second generation VLT instrument MUSE, we discuss properties of the data will look like and present challenges and goals of its data reduction software. It is conceived as a number of pipeline recipes to be run in an automated way within the ESO data flow system. These recipes are based on a data reduction library that is being written in the C language using ESO's CPL API. We give a short overview of the steps needed for reduction and post-processing of science data, discuss requirements of a future visualization tool for integral field spectroscopy and close with the timeline for MUSE and its data reduction pipeline.

  9. Wave Pipelining Using Self Reset Logic

    Directory of Open Access Journals (Sweden)

    Miguel E. Litvin

    2008-01-01

    Full Text Available This study presents a novel design approach combining wave pipelining and self reset logic, which provides an elegant solution at high-speed data throughput with significant savings in power and area as compared with other dynamic CMOS logic implementations. To overcome some limitations in SRL art, we employ a new SRL family, namely, dual-rail self reset logic with input disable (DRSRL-ID. These gates depict fairly constant timing parameters, specially the width of the output pulse, for varying fan-out and logic depth, helping accommodate process, supply voltage, and temperature variations (PVT. These properties simplify the implementation of wave pipelined circuits. General timing analysis is provided and compared with previous implementations. Results of circuit implementation are presented together with conclusions and future work.

  10. Crossing Active Faults on the Sakhalin II Onshore Pipeline Route: Pipeline Design and Risk Analysis

    Science.gov (United States)

    Mattiozzi, Pierpaolo; Strom, Alexander

    2008-07-01

    Twin oil (20 & 24 inch) and gas (20 & 48 inch) pipeline systems stretching 800 km are being constructed to connect offshore hydrocarbon deposits from the Sakhalin II concession in the North to an LNG plant and oil export terminal in the South of Sakhalin island. The onshore pipeline route follows a regional fault zone and crosses individual active faults at 19 locations. Sakhalin Energy, Design and Construction companies took significant care to ensure the integrity of the pipelines, should large seismic induced ground movements occur during the Operational life of the facilities. Complex investigations including the identification of the active faults, their precise location, their particular displacement values and assessment of the fault kinematics were carried out to provide input data for unique design solutions. Lateral and reverse offset displacements of 5.5 and 4.5 m respectively were determined as the single-event values for the design level earthquake (DLE)—the 1000-year return period event. Within the constraints of a pipeline route largely fixed, the underground pipeline fault crossing design was developed to define the optimum routing which would minimize stresses and strain using linepipe materials which had been ordered prior to the completion of detailed design, and to specify requirements for pipe trenching shape, materials, drainage system, etc. Detailed Design was performed with due regard to actual topography and to avoid the possibility of the trenches freezing in winter, the implementation of specific drainage solutions and thermal protection measures.

  11. Crossing Active Faults on the Sakhalin II Onshore Pipeline Route: Pipeline Design and Risk Analysis

    International Nuclear Information System (INIS)

    Twin oil (20 and 24 inch) and gas (20 and 48 inch) pipeline systems stretching 800 km are being constructed to connect offshore hydrocarbon deposits from the Sakhalin II concession in the North to an LNG plant and oil export terminal in the South of Sakhalin island. The onshore pipeline route follows a regional fault zone and crosses individual active faults at 19 locations. Sakhalin Energy, Design and Construction companies took significant care to ensure the integrity of the pipelines, should large seismic induced ground movements occur during the Operational life of the facilities. Complex investigations including the identification of the active faults, their precise location, their particular displacement values and assessment of the fault kinematics were carried out to provide input data for unique design solutions. Lateral and reverse offset displacements of 5.5 and 4.5 m respectively were determined as the single-event values for the design level earthquake (DLE) - the 1000-year return period event. Within the constraints of a pipeline route largely fixed, the underground pipeline fault crossing design was developed to define the optimum routing which would minimize stresses and strain using linepipe materials which had been ordered prior to the completion of detailed design, and to specify requirements for pipe trenching shape, materials, drainage system, etc. Detailed Design was performed with due regard to actual topography and to avoid the possibility of the trenches freezing in winter, the implementation of specific drainage solutions and thermal protection measures

  12. CO2 pipelines material and safety considerations

    OpenAIRE

    Bilio, M.; S. Brown; Fairweather, M.; Mahgerefteh, H.; IChemE

    2009-01-01

    This paper presents an overview of some of the most important factors and areas of uncertainty affecting integrity and accurate hazard assessment of CO2 pipelines employed as part of the Carbon Capture and Sequestration (CCS) chain. These include corrosion, hydrate formation, hydrogen embrittlement and propensity to fast running ductile and brittle factures. Special consideration is given to the impact of impurities within the CO2 feed from the various capture technologies on t...

  13. Grooving corrosion of seam welded oil pipelines

    OpenAIRE

    Mohamed Hanafy El-Sayed

    2014-01-01

    24” pipeline carrying oil was failed in the form of longitudinal crack at the 6 O’clock position resulting in oil spill. The failed pipe was investigated to reveal the main cause of its failure. The procedure of investigation was built on studying the intact pipe, rupture area, parent material, and intact weld. Results of chemical analysis, mechanical properties, and microstructure of the pipe material were confirmed with the specified standard. Cracks were originated from weld defected sites...

  14. Sensor Network Architectures for Monitoring Underwater Pipelines

    OpenAIRE

    Imad Jawhar; Jameela Al-Jaroodi; Nader Mohamed; Liren Zhang

    2011-01-01

    This paper develops and compares different sensor network architecture designs that can be used for monitoring underwater pipeline infrastructures. These architectures are underwater wired sensor networks, underwater acoustic wireless sensor networks, RF (Radio Frequency) wireless sensor networks, integrated wired/acoustic wireless sensor networks, and integrated wired/RF wireless sensor networks. The paper also discusses the reliability challenges and enhancement approaches for these network...

  15. Grape RNA-Seq analysis pipeline environment

    OpenAIRE

    KNOWLES, D. G.; Roder, M.; Merkel, A.; Guigo, R.

    2013-01-01

    Motivation: The avalanche of data arriving since the development of NGS technologies have prompted the need for developing fast, accurate and easily automated bioinformatic tools capable of dealing with massive datasets. Among the most productive applications of NGS technologies is the sequencing of cellular RNA, known as RNA-Seq. Although RNA-Seq provides similar or superior dynamic range than microarrays at similar or lower cost, the lack of standard and user-friendly pipelines is a bottlen...

  16. Natural gas pipeline leaks across Washington, DC.

    Science.gov (United States)

    Jackson, Robert B; Down, Adrian; Phillips, Nathan G; Ackley, Robert C; Cook, Charles W; Plata, Desiree L; Zhao, Kaiguang

    2014-01-01

    Pipeline safety in the United States has increased in recent decades, but incidents involving natural gas pipelines still cause an average of 17 fatalities and $133 M in property damage annually. Natural gas leaks are also the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. To reduce pipeline leakage and increase consumer safety, we deployed a Picarro G2301 Cavity Ring-Down Spectrometer in a car, mapping 5893 natural gas leaks (2.5 to 88.6 ppm CH4) across 1500 road miles of Washington, DC. The δ(13)C-isotopic signatures of the methane (-38.2‰ ± 3.9‰ s.d.) and ethane (-36.5 ± 1.1 s.d.) and the CH4:C2H6 ratios (25.5 ± 8.9 s.d.) closely matched the pipeline gas (-39.0‰ and -36.2‰ for methane and ethane; 19.0 for CH4/C2H6). Emissions from four street leaks ranged from 9200 to 38,200 L CH4 day(-1) each, comparable to natural gas used by 1.7 to 7.0 homes, respectively. At 19 tested locations, 12 potentially explosive (Grade 1) methane concentrations of 50,000 to 500,000 ppm were detected in manholes. Financial incentives and targeted programs among companies, public utility commissions, and scientists to reduce leaks and replace old cast-iron pipes will improve consumer safety and air quality, save money, and lower greenhouse gas emissions.

  17. Cogeneration: A marketing opportunity for pipelines

    International Nuclear Information System (INIS)

    This chapter describes the marketing of dual-purpose power plants by pipeline companies as a long term marketing strategy for natural gas. The author uses case studies to help evaluate a company's attitude toward development of a market for cogeneration facilities. The chapter focuses on strategies for developing markets in the industrial sector and identifying customer groups that are likely to respond in like manner to a marketing strategy

  18. Inpatient capsule endoscopy leads to frequent incomplete small bowel examinations

    Institute of Scientific and Technical Information of China (English)

    Cemal Yazici; John Losurdo; Michael D Brown; Scott Oosterveen; Robert Rahimi; Ali Keshavarzian; Leila Bozorgnia

    2012-01-01

    AIM:To examine the predictive factors of capsule endoscopy (CE) completion rate (CECR) including the effect of inpatient and outpatient status.METHODS:We identified 355 consecutive patients who completed CE at Rush University Medical Center between March 2003 and October 2005.Subjects for CE had either nothing by mouth or clear liquids for the afternoon and evening of the day before the procedure.CE exams were reviewed by two physicians who were unaware of the study hypotheses.After retrospective analysis,21 cases were excluded due to capsule malfunction,prior gastric surgery,endoscopic capsule placement or insufficient data.Of the remaining 334 exams [264 out-patient (OP),70 in-patient (IP)],CE indications,findings,location of the patients [IP vs OP and intensive care unit (ICU) vs general medical floor (GMF)] and gastrointestinal transit times were analyzed.Statistical analysis was completed using SPSS version 17 (Chicago,IL).Chi-square,t test or fisher exact-tests were used as appropriate.Multivariate logistic regression analysis was used to identify variables associated with incomplete CE exams.RESULTS:The mean age for the entire study population was 54.7 years.Sixty-one percent of the study population was female,and gender was not different between IPs vs OPs (P =0.07).The overall incomplete CECR was 14% in our study.Overt obscure gastrointestinal bleeding (OGB) was significantly more common for the IP CE (P =0.0001),while abdominal pain and assessment of IBD were more frequent indications for the OP CE exams (P =0.002 and P =0.01,respectively).Occult OGB was the most common indication and arteriovenous malformations were the most common finding both in the IPs and OPs.The capsule did not enter the small bowel (SB) in 6/70 IPs and 8/264OPs (P =0.04).The capsule never reached the cecum in 31.4% (22/70) of IP vs 9.5% (25/ 264) of OP examinations (P < 0.001).The mean gastric transit time (GTT) was delayed in IPs compared to OPs,98.5 ±139.5 min vs 60.4

  19. Interaction between soils and gas pipelines

    Science.gov (United States)

    Karpachevskii, L. O.; Goroshevskii, A. V.; Zubkova, T. A.

    2011-03-01

    The interaction between pipelines and soils manifests itself in the soil disturbance in the course of the pipe installation, in the transformation of the water and temperature regimes in the trenches, and in the appearance of corrosion and cracks on the pipe walls. The more contrasting the soil water regime in the pipe-adjacent sections of the trench, the greater the amount of the pipe damage. The damage of the pipe insulation activates the pipe corrosion. The emission of gases (H2S, CH4, CO2, CO, and H2) and the activity of sulfate-reducing bacteria are the main causes of the pipes' destruction. The humus content and the redox potential decrease, and the soil density and concentrations of ferrous compounds increase in the soils of the trench zone. Accidents along pipelines occur most often in the area of serozems and chestnut soils, and this is related to the salinization in the lower soil horizons and to the contrasting soil water regime near the pipe. The number of accidents along the pipelines installed into soddy-podzolic soils is lower.

  20. The GALAH survey: The data reduction pipeline

    Science.gov (United States)

    Kos, Janez; Lin, Jane; Zwitter, Tomaž; Žerjal, Maruška; Sharma, Sanjib; Bland-Hawthorn, Joss; Asplund, Martin; Casey, Andrew R.; De Silva, Gayandhi M.; Freeman, Ken C.; Martell, Sarah L.; Simpson, Jeffrey D.; Schlesinger, Katharine J.; Zucker, Daniel; Anguiano, Borja; Bacigalupo, Carlos; Bedding, Timothy R.; Betters, Christopher; Da Costa, Gary; Duong, Ly; Hyde, Elaina; Ireland, Michael; Kafle, Prajwal R.; Leon-Saval, Sergio; Lewis, Geraint F.; Munari, Ulisse; Nataf, David; Stello, Dennis; Tinney, Chris G.; Traven, Gregor; Watson, Fred; Wittenmyer, Robert A.

    2016-08-01

    We present the data reduction procedures being used by the GALAH survey, carried out with the HERMES fibre-fed, multi-object spectrograph on the 3.9 m Anglo-Australian Telescope. GALAH is a unique survey, targeting 1 million stars brighter than magnitude V=14 at a resolution of 28,000 with a goal to measure the abundances of 29 elements. Such a large number of high resolution spectra necessitates the development of a reduction pipeline optimized for speed, accuracy, and consistency. We outline the design and structure of the Iraf-based reduction pipeline that we developed, specifically for GALAH, to produce fully calibrated spectra aimed for subsequent stellar atmospheric parameter estimation. The pipeline takes advantage of existing Iraf routines and other readily available software so as to be simple to maintain, testable and reliable. A radial velocity and stellar atmospheric parameter estimator code is also presented, which is used for further data analysis and yields a useful verification of the reduction quality. We have used this estimator to quantify the data quality of GALAH for fibre cross-talk level (≲ 0.5%) and scattered light (˜5 counts in a typical 20 minutes exposure), resolution across the field, sky spectrum properties, wavelength solution reliability (better than 1 km s-1 accuracy) and radial velocity precision.