WorldWideScience

Sample records for capsule endoscopy increase

  1. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Why it's done Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  2. Magnetically guided capsule endoscopy.

    Science.gov (United States)

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  3. Capsule endoscopy: Beyond small bowel

    Directory of Open Access Journals (Sweden)

    Samuel N Adler

    2012-01-01

    Full Text Available In this article the brief and dramatic history of capsule endoscopy of the digestive tract is reviewed. Capsule endoscopy offers a non invasive method to diagnose diseases that affect the esophagus, small bowel and colon. Technological improvements relating to optics, software, data recorders with two way communication have revolutionized this field. These advancements have produced better diagnostic performance.

  4. Contraindications for video capsule endoscopy

    OpenAIRE

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn?s dise...

  5. Increased diagnostic yield of capsule endoscopy in patients with chronic abdominal pain.

    Directory of Open Access Journals (Sweden)

    Liping Yang

    Full Text Available BACKGROUND AND STUDY AIMS: Chronic abdominal pain is one of the most common chief complaints, but the underlying pathophysiology often remains unknown after routine clinical evaluation. Capsule endoscopy (CE is a new technique for the visualization of the entire small bowel. The aim of this study was to evaluate the diagnostic efficacy of CE in patients with chronic abdominal pain of obscure origin. PATIENTS AND METHODS: Two hundred forty three patients with chronic abdominal pain with no significant lesions were enrolled in this study. CE was performed in all patients. RESULTS: A diagnosis was made in 23.0% of patients screened with CE. Of the 243 patients, 19 (7.8% were diagnosed with Crohn's disease, 15 (6.2% with enteritis, 11 (4.5% with idiopathic intestinal lymphangiectasia, 5 (2.1% with uncinariasis, and a number of other diagnoses including small bowel tumor, ascariasis, and anaphylactoid purpura. Five patients had abnormal transit time, and capsule retention occurred in two patients. CONCLUSIONS: In contrast to other previous studies, we found that CE is an effective diagnostic tool for patients with abdominal pain.

  6. NASPGHAN Capsule Endoscopy Clinical Report.

    Science.gov (United States)

    Friedlander, Joel A; Liu, Quin Y; Sahn, Benjamin; Kooros, Koorosh; Walsh, Catharine M; Kramer, Robert E; Lightdale, Jenifer R; Khlevner, Julie; McOmber, Mark; Kurowski, Jacob; Giefer, Matthew J; Pall, Harpreet; Troendle, David M; Utterson, Elizabeth C; Brill, Herbert; Zacur, George M; Lirio, Richard A; Lerner, Diana G; Reynolds, Carrie; Gibbons, Troy E; Wilsey, Michael; Liacouras, Chris A; Fishman, Douglas S

    2017-03-01

    Wireless capsule endoscopy (CE) was introduced in 2000 as a less invasive method to visualize the distal small bowel in adults. Because this technology has advanced it has been adapted for use in pediatric gastroenterology. Several studies have described its clinical use, utility, and various training methods but pediatric literature regarding CE is limited. This clinical report developed by the Endoscopic and Procedures Committee of the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition outlines the current literature, and describes the recommended current role, use, training, and future areas of research for CE in pediatrics.

  7. Stochastic Capsule Endoscopy Image Enhancement

    Directory of Open Access Journals (Sweden)

    Ahmed Mohammed

    2018-06-01

    Full Text Available Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.

  8. Capsule endoscopy in neoplastic diseases

    Science.gov (United States)

    Pennazio, Marco; Rondonotti, Emanuele; de Franchis, Roberto

    2008-01-01

    Until recently, diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High-quality images of the small-bowel mucosa may be captured and small and flat lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings, remains to be determined through carefully-designed studies. PMID:18785274

  9. A Simple Evaluation Tool (ET-CET) Indicates Increase of Diagnostic Skills From Small Bowel Capsule Endoscopy Training Courses

    OpenAIRE

    Albert, J.G.; Humbla, O.; McAlindon, M.E.; Davison, C.; Seitz, U.; Fraser, C.; Hagenm?ller, F.; Noetzel, E.; Spada, C.; Riccioni, M.E.; Barnert, J.; Filmann, N.; Keuchel, M.

    2015-01-01

    Abstract Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse. Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n?=?2), Italy (n?=?2), Germany (n?=?2), Finland (n?=?1), and nationally in Germany (n?=?10), applying similar 8-hour curricula with 50% lectures and 50% hands-on t...

  10. A Simple Evaluation Tool (ET-CET) Indicates Increase of Diagnostic Skills From Small Bowel Capsule Endoscopy Training Courses

    Science.gov (United States)

    Albert, J.G.; Humbla, O.; McAlindon, M.E.; Davison, C.; Seitz, U.; Fraser, C.; Hagenmüller, F.; Noetzel, E.; Spada, C.; Riccioni, M.E.; Barnert, J.; Filmann, N.; Keuchel, M.

    2015-01-01

    Abstract Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse. Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n = 2), Italy (n = 2), Germany (n = 2), Finland (n = 1), and nationally in Germany (n = 10), applying similar 8-hour curricula with 50% lectures and 50% hands-on training. The Given PillCam System was used in 12 courses, the Olympus EndoCapsule system in 5, respectively. A simple evaluation tool for capsule endoscopy training (ET-CET) was developed using 10 short SBCE videos including relevant lesions and normal or irrelevant findings. For each video, delegates were required to record a diagnosis (achievable total score from 0 to 10) and the clinical relevance (achievable total score 0 to 10). ET-CET was performed at baseline before the course and repeated, with videos in altered order, after the course. Two hundred ninety-four delegates (79.3% physicians, 16.3% nurses, 4.4% others) were included for baseline analysis, 268 completed the final evaluation. Forty percent had no previous experience in SBCE, 33% had performed 10 or less procedures. Median scores for correct diagnosis improved from 4.0 (IQR 3) to 7.0 (IQR 3) during the courses (P endoscopy may be useful before attending an SBCE course. PMID:26512623

  11. Automatic blood detection in capsule endoscopy video

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Flusser, Jan; Tachecí, I.; Sulík, L.; Bureš, J.; Krejcar, O.

    2016-01-01

    Roč. 21, č. 12 (2016), s. 1-8, č. článku 126007. ISSN 1083-3668 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985556 Keywords : Automatic blood detection * capsule endoscopy video Subject RIV: JD - Computer Applications, Robotics Impact factor: 2.530, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/flusser-0466936.pdf

  12. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  13. What we have learned and what to expect from capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N; Bjarnason, Ingvar

    2012-10-16

    Capsule endoscopy was conceived by Gabriel Iddan and Paul Swain independently two decades ago. These applications include but are not limited to Crohn's disease of the small bowel, occult gastrointestinal bleeding, non steroidal anti inflammatory drug induced small bowel disease, carcinoid tumors of the small bowel, gastro intestinal stromal tumors of the small bowel and other disease affecting the small bowel. Capsule endoscopy has been compared to traditional small bowel series, computerized tomography studies and push enteroscopy. The diagnostic yield of capsule endoscopy has consistently been superior in the diagnosis of small bowel disease compared to the competing methods (small bowel series, computerized tomography, push enteroscopy) of diagnosis. For this reason capsule endoscopy has enjoyed a meteoric success. Image quality has been improved with increased number of pixels, automatic light exposure adaptation and wider angle of view. Further applications of capsule endoscopy of other areas of the digestive tract are being explored. The increased transmission rate of images per second has made capsule endoscopy of the esophagus a realistic possibility. Technological advances that include a double imager capsule with a nearly panoramic view of the colon and a variable frame rate adjusted to the movement of the capsule in the colon have made capsule endoscopy of the colon feasible. The diagnostic rate for the identification of patients with polyps equal to or larger than 6 mm is high. Future advances in technology and biotechnology will lead to further progress. Capsule endoscopy is following the successful modern trend in medicine that replaces invasive tests with less invasive methodology.

  14. A Simple Evaluation Tool (ET-CET) Indicates Increase of Diagnostic Skills From Small Bowel Capsule Endoscopy Training Courses: A Prospective Observational European Multicenter Study.

    Science.gov (United States)

    Albert, J G; Humbla, O; McAlindon, M E; Davison, C; Seitz, U; Fraser, C; Hagenmüller, F; Noetzel, E; Spada, C; Riccioni, M E; Barnert, J; Filmann, N; Keuchel, M

    2015-10-01

    Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse.Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n = 2), Italy (n = 2), Germany (n = 2), Finland (n = 1), and nationally in Germany (n = 10), applying similar 8-hour curricula with 50% lectures and 50% hands-on training. The Given PillCam System was used in 12 courses, the Olympus EndoCapsule system in 5, respectively. A simple evaluation tool for capsule endoscopy training (ET-CET) was developed using 10 short SBCE videos including relevant lesions and normal or irrelevant findings. For each video, delegates were required to record a diagnosis (achievable total score from 0 to 10) and the clinical relevance (achievable total score 0 to 10). ET-CET was performed at baseline before the course and repeated, with videos in altered order, after the course.Two hundred ninety-four delegates (79.3% physicians, 16.3% nurses, 4.4% others) were included for baseline analysis, 268 completed the final evaluation. Forty percent had no previous experience in SBCE, 33% had performed 10 or less procedures. Median scores for correct diagnosis improved from 4.0 (IQR 3) to 7.0 (IQR 3) during the courses (P endoscopy may be useful before attending an SBCE course.

  15. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  16. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  17. Polyp Detection and Segmentation from Video Capsule Endoscopy: A Review

    Directory of Open Access Journals (Sweden)

    V. B. Surya Prasath

    2016-12-01

    Full Text Available Video capsule endoscopy (VCE is used widely nowadays for visualizing the gastrointestinal (GI tract. Capsule endoscopy exams are prescribed usually as an additional monitoring mechanism and can help in identifying polyps, bleeding, etc. To analyze the large scale video data produced by VCE exams, automatic image processing, computer vision, and learning algorithms are required. Recently, automatic polyp detection algorithms have been proposed with various degrees of success. Though polyp detection in colonoscopy and other traditional endoscopy procedure based images is becoming a mature field, due to its unique imaging characteristics, detecting polyps automatically in VCE is a hard problem. We review different polyp detection approaches for VCE imagery and provide systematic analysis with challenges faced by standard image processing and computer vision methods.

  18. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  19. Engineering Micromechanical Systems for the Next Generation Wireless Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Stephen Woods

    2015-01-01

    Full Text Available Wireless capsule endoscopy (WCE enables the detection and diagnosis of inflammatory bowel diseases such as Crohn’s disease and ulcerative colitis. However treatment of these pathologies can only be achieved through conventional means. This paper describes the next generation WCE with increased functionality to enable targeted drug delivery in the small intestinal tract. A prototype microrobot fabricated in Nylon 6 is presented which is capable of resisting peristaltic pressure through the deployment of an integrated holding mechanism and delivering targeted therapy. The holding action is achieved by extending an “anchor” spanning a 60.4 mm circumference, for an 11.0 mm diameter WCE. This function is achieved by a mechanism that occupies only 347.0 mm3 volume, including mechanics and actuator. A micropositioning mechanism is described which utilises a single micromotor to radially position and then deploy a needle 1.5 mm outside the microrobot’s body to deliver a 1 mL dose of medication to a targeted site. An analysis of the mechanics required to drive the holding mechanism is presented and an overview of microactuators and the state of the art in WCE is discussed. It is envisaged that this novel functionality will empower the next generation of WCE to help diagnose and treat pathologies of the GI tract.

  20. Engineering Micromechanical Systems for the Next Generation Wireless Capsule Endoscopy

    Science.gov (United States)

    Woods, Stephen; Constandinou, Timothy

    2015-01-01

    Wireless capsule endoscopy (WCE) enables the detection and diagnosis of inflammatory bowel diseases such as Crohn's disease and ulcerative colitis. However treatment of these pathologies can only be achieved through conventional means. This paper describes the next generation WCE with increased functionality to enable targeted drug delivery in the small intestinal tract. A prototype microrobot fabricated in Nylon 6 is presented which is capable of resisting peristaltic pressure through the deployment of an integrated holding mechanism and delivering targeted therapy. The holding action is achieved by extending an “anchor” spanning a 60.4 mm circumference, for an 11.0 mm diameter WCE. This function is achieved by a mechanism that occupies only 347.0 mm3 volume, including mechanics and actuator. A micropositioning mechanism is described which utilises a single micromotor to radially position and then deploy a needle 1.5 mm outside the microrobot's body to deliver a 1 mL dose of medication to a targeted site. An analysis of the mechanics required to drive the holding mechanism is presented and an overview of microactuators and the state of the art in WCE is discussed. It is envisaged that this novel functionality will empower the next generation of WCE to help diagnose and treat pathologies of the GI tract. PMID:26258143

  1. Blood detection in wireless capsule endoscopy using expectation maximization clustering

    Science.gov (United States)

    Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.

    2006-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.

  2. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  3. A modular and programmable development platform for capsule endoscopy system.

    Science.gov (United States)

    Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A

    2014-06-01

    The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.

  4. Non-small-bowel abnormalities identified during small bowel capsule endoscopy

    NARCIS (Netherlands)

    Hoedemakers, Reinier; Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2014-01-01

    AIM: To investigate the incidence of non-small-bowel abnormalities in patients referred for small bowel capsule endoscopy, this single center study was performed. METHODS: Small bowel capsule endoscopy is an accepted technique to investigate obscure gastrointestinal bleeding. This is defined as

  5. Portable wireless power transmission system for video capsule endoscopy.

    Science.gov (United States)

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  6. Small-bowel neoplasms in patients undergoing video capsule endoscopy

    DEFF Research Database (Denmark)

    Rondonotti, E; Pennazio, M; Toth, E

    2008-01-01

    BACKGROUND AND STUDY AIM: Small-bowel tumors account for 1% - 3% of all gastrointestinal neoplasms. Recent studies with video capsule endoscopy (VCE) suggest that the frequency of these tumors may be substantially higher than previously reported. The aim of the study was to evaluate the frequency......, clinical presentation, diagnostic/therapeutic work-up, and endoscopic appearance of small-bowel tumors in a large population of patients undergoing VCE. PATIENTS AND METHODS: Identification by a questionnaire of patients with VCE findings suggesting small-bowel tumors and histological confirmation...... of the neoplasm seen in 29 centers of 10 European Countries. RESULTS: Of 5129 patients undergoing VCE, 124 (2.4%) had small-bowel tumors (112 primary, 12 metastatic). Among these patients, indications for VCE were: obscure gastrointestinal bleeding (108 patients), abdominal pain (9), search for primary neoplasm...

  7. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals

    DEFF Research Database (Denmark)

    Kobaek-Larsen, Morten; Kroijer, Rasmus; Dyrvig, Anne-Kirstine

    2018-01-01

    mm polyps in colon capsule endoscopy (97%; 95% CI: 94-100) was superior to colonoscopy (89%; 95% CI: 84-94). A complete capsule endoscopy examination (N=134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity...... and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp >10 mm or more than two polyps. CONCLUSION: Colon capsule endoscopy is superior to colonoscopy in polyp detection rate and per-patient sensitivity to >9 mm polyps, but only in complete CCE examinations. The rate...

  8. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    Chen, Wenwen; Yan, Guozheng; He, Shu; Ke, Quan; Wang, Zhiwu; Liu, Hua; Jiang, Pingping

    2013-01-01

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  9. Current Status and Research into Overcoming Limitations of Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Won Gun Kwack

    2016-01-01

    Full Text Available Endoscopic investigation has a critical role in the diagnosis and treatment of gastrointestinal (GI diseases. Since 2001, capsule endoscopy (CE has been available for small-bowel exploration and is under continuous development. During the past decade, CE has achieved impressive improvements in areas such as miniaturization, resolution, and battery life. As a result, CE is currently a first-line tool for the investigation of the small bowel in obscure gastrointestinal bleeding and is a useful alternative to wired enteroscopy. Nevertheless, CE still has several limitations, such as incomplete examination and limited diagnostic and therapeutic capabilities. To resolve these problems, many groups have suggested several models (e.g., controlled CO2 insufflation system, magnetic navigation system, mobile robotic platform, tagging and biopsy equipment, and targeted drug-delivery system, which are in development. In the near future, new technological advances will improve the capabilities of CE and broaden its spectrum of applications not only for the small bowel but also for the colon, stomach, and esophagus. The purpose of this review is to introduce the current status of CE and to review the ongoing development of solutions to address its limitations.

  10. Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy

    Science.gov (United States)

    Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young

    2011-01-01

    Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841

  11. Capsule endoscopy for the detection of oesophageal mucosal disorders: a comparison of two different ingestion protocols

    NARCIS (Netherlands)

    de Jonge, Pieter J. F.; van Eijck, Brechje C.; Geldof, Han; Bekkering, Frank C.; Essink-Bot, Marie-Louise; Polinder, Suzanne; Kuipers, Ernst J.; Siersema, Peter D.

    2008-01-01

    OBJECTIVE: To assess the accuracy of a new ingestion protocol for capsule endoscopy (CE) in evaluating patients with gastro-oesophageal reflux disease (GORD). METHODS: Oesophago-gastroduodenoscopy (OGD) was performed 1 week prior to CE. The first 28 subjects swallowed the capsule following the

  12. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  13. Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Simpson, Kenneth W; Bowman, Dwight D

    2011-11-01

    The current accepted standard for evaluating the efficacy of gastrointestinal anthelmintic drugs is necropsy of infected animals followed by a comparison of worm counts between treated and non-treated groups. In this study capsule endoscopy, a minimally invasive method of imaging the small intestine of humans, is evaluated as a possible alternative to necropsy for the purposes of worm quantification in dogs. Eighteen Beagle dogs were included in this study. These dogs were part of a separate trial intended to determine the efficacy of various candidate parasiticides against Ancylostoma caninum via the necropsy standard. Dogs were inoculated with A. caninum L3s 4 weeks prior to treatment with one of the candidate compounds; a control group (n=8) received no treatment. Capsule endoscopy was performed 6-14 days post-treatment, followed by necropsy the following day. Seventeen dogs had complete examinations, i.e. the capsule traversed the small intestine and reached the colon within the battery life of the capsule. A strong correlation (r(s)=0.87, Pcapsule endoscopy and necropsy. There was no clear relationship between the ability of the capsule endoscope to detect hookworms and either visibility of the intestinal lumen or small intestinal transit time. Generation of a virtual spatial record of hookworm location from the capsule endoscopy data revealed a temporal trend, with the majority of worms present in the proximal small intestine in the morning versus the central to distal small intestine in the afternoon. Worm distribution as determined by capsule endoscopy closely resembled post-mortem findings. In conclusion, capsule endoscopy shows promise as an alternative to necropsy for the enumeration of A. caninum in the canine small intestine, although further work is required to improve completion rates and optimise intestinal examination. Copyright © 2011 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

  14. Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.

    Science.gov (United States)

    Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel

    2017-01-01

    The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  15. A Machine Learning Approach for Intestinal Motility Assessment with Capsule Endoscopy

    OpenAIRE

    Vilariño Freire, Fernando Luis

    2006-01-01

    Consultable des del TDX Intestinal motility assessment with video capsule endoscopy arises as a novel and challenging clinical fieldwork. This technique is based on the analysis of the patterns of intestinal contractions obtained by labelling all the motility events present in a video provided by a capsule with a wireless micro-camera, which is ingested by the patient. However, the visual analysis of these video sequences presents several important drawbacks, mainly related to both the lar...

  16. Correlation between predicted and actual consequences of capsule endoscopy on patient management

    NARCIS (Netherlands)

    Westerhof, J.; Weersma, R. K.; Thijs, W. J.; Limburg, A. J.; Koornstra, J. J.; de Graaf, A.P.

    Background. Capsule endoscopy (CE) is a relatively new diagnostic modality in the evaluation of patients with suspected small bowel pathology. It is unclear to what extent physicians are able to predict the clinical consequences of CE on patient management. Methods. In this prospective study, 180

  17. High sensitivity of quick view capsule endoscopy for detection of small bowel Crohn's disease

    DEFF Research Database (Denmark)

    Halling, Morten Lee; Nathan, Torben; Kjeldsen, Jens

    2014-01-01

    Capsule endoscopy (CE) has a high sensitivity for diagnosing small bowel Crohn's disease, but video analysis is time consuming. The quick view (qv) function is an effective tool to reduce time consumption. The aim of this study was to determine the rate of missed small bowel ulcerations with qv-C...

  18. Prevalence of small-bowel neoplasia in Lynch syndrome assessed by video capsule endoscopy

    NARCIS (Netherlands)

    Haanstra, Jasmijn F.; Al-Toma, Abdul; Dekker, Evelien; Vanhoutvin, Steven A. L. W.; Nagengast, Fokko M.; Mathus-Vliegen, Elisabeth M.; van Leerdam, Monique E.; de Vos tot Nederveen Cappel, Wouter H.; Sanduleanu, Silvia; Veenendaal, Roeland A.; Cats, Annemieke; Vasen, Hans F. A.; Kleibeuker, Jan H.; Koornstra, Jan J.

    2015-01-01

    The aim was to determine the prevalence of small-bowel neoplasia in asymptomatic patients with Lynch syndrome (LS) by video capsule endoscopy (VCE). After obtaining informed consent, asymptomatic proven gene mutation carriers aged 35-70 years were included in this prospective multicentre study in

  19. Prevalence of small-bowel neoplasia in Lynch syndrome assessed by video capsule endoscopy

    NARCIS (Netherlands)

    Haanstra, Jasmijn F.; Al-Toma, Abdul; Dekker, Evelien; Vanhoutvin, Steven A. L. W.; Nagengast, Fokko M.; Mathus-Vliegen, Elisabeth M.; van Leerdam, Monique E.; Cappel, Wouter H. de Vos tot Nederveen; Sanduleanu, Silvia; Veenendaal, Roeland A.; Cats, Annemieke; Vasen, Hans F. A.; Kleibeuker, Jan H.; Koornstra, Jan J.

    2015-01-01

    Objective The aim was to determine the prevalence of small-bowel neoplasia in asymptomatic patients with Lynch syndrome (LS) by video capsule endoscopy (VCE). Design After obtaining informed consent, asymptomatic proven gene mutation carriers aged 3570 years were included in this prospective

  20. Capsule endoscopy for the diagnosis and follow up of crohn’s disease

    DEFF Research Database (Denmark)

    Jensen, Michael Dam; Brodersen, Jacob; Kjeldsen, Jens

    2017-01-01

    Capsule endoscopy (CE) has revolutionized the diagnosis and monitoring of small bowel Crohn’s disease (CD). the procedure is patient friendly and noninvasive, and compared to cross-sectional imaging, CE allows a direct and detailed evaluation of the entire small bowel mucosa witha high sensitivit...

  1. Historical analysis of experience with small bowel capsule endoscopy in a spanish tertiary hospital.

    Science.gov (United States)

    Egea Valenzuela, Juan; Carrilero Zaragoza, Gabriel; Iglesias Jorquera, Elena; Tomás Pujante, Paula; Alberca de Las Parras, Fernando; Carballo Álvarez, Fernando

    2017-02-01

    Capsule endoscopy was approved by the FDA in 2001. Gastrointestinal bleeding and inflammatory bowel disease are the main indications. It has been available in our hospital since 2004. We retrospectively analysed data from patients who underwent small bowel capsule endoscopy in our hospital from October 2004 to April 2015. Indications were divided into: Obscure gastrointestinal bleeding (occult and overt), inflammatory bowel disease, and other indications. Findings were divided into: Vascular lesions, inflammatory lesions, other lesions, normal studies, and inconclusive studies. A total of 1027 out of 1291 small bowel studies were included. Mean patient age was 56.45 years; 471 were men and 556 women. The most common lesion observed was angiectasia, as an isolated finding or associated with other lesions. Findings were significant in up to 80% of studies when the indication was gastrointestinal bleeding, but in only 50% of studies in inflammatory bowel disease. Diagnostic yield was low in the group «other indications». No major complications were reported. Small bowel capsule endoscopy has high diagnostic yield in patients with gastrointestinal bleeding, but yield is lower in patients with inflammatory bowel disease. Our experience shows that capsule endoscopy is a safe and useful tool for the diagnosis of small bowel disease. The diagnostic yield of the technique in inflammatory bowel disease must be improved. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  2. Capsule Endoscopy in the Investigation of Patients with Portal Hypertension and Anemia

    Directory of Open Access Journals (Sweden)

    Spyros Goulas

    2008-01-01

    Full Text Available INTRODUCTION: Data on small bowel abnormalities in patients with portal hypertension (PHT are limited. Bleeding from the gastrointestinal tract and anemia are common complications in these patients. Capsule endoscopy (CE was used to evaluate small bowel (SB pathology in patients with PHT and anemia, and possible associations with various parameters were examined.

  3. Advances in pediatric gastroenterology: introducing video camera capsule endoscopy.

    Science.gov (United States)

    Siaw, Emmanuel O

    2006-04-01

    The video camera capsule endoscope is a gastrointestinal endoscope approved by the U.S. Food and Drug Administration in 2001 for use in diagnosing gastrointestinal disorders in adults. In 2003, the agency approved the device for use in children ages 10 and older, and the endoscope is currently in use at Arkansas Children's Hospital. A capsule camera, lens, battery, transmitter and antenna together record images of the small intestine as the endoscope makes its way through the bowel. The instrument is used with minimal risk to the patient while offering a high degree of accuracy in diagnosing small intestine disorders.

  4. Assessment of an electronic learning system for colon capsule endoscopy: a pilot study.

    Science.gov (United States)

    Watabe, Hirotsugu; Nakamura, Tetsuya; Yamada, Atsuo; Kakugawa, Yasuo; Nouda, Sadaharu; Terano, Akira

    2016-06-01

    Training for colon capsule endoscopy (CCE) procedures is currently performed as a lecture and hands-on seminar. The aims of this pilot study were to assess the utility of an electronic learning system for CCE (ELCCE) designed for the Japanese Association for Capsule Endoscopy using an objective scoring engine, and to evaluate the efficacy of ELCCE on the acquisition of CCE reading competence. ELCCE is an Internet-based learning system with the following steps: step 1, introduction; step 2, CCE reading competence assessment test (CCAT), which evaluates the competence of CCE reading prior to training; step 3, learning reading theory; step 4, training with guidance; step 5, training without guidance; step 6, final assessment; and step 7, the same as step 2. The CCAT, step 5 and step 6 were scored automatically according to: lesion detection, diagnosis (location, size, shape of lesion), management recommendations, and quality of view. Ten trainee endoscopists were initially recruited (cohort 1), followed by a validating cohort of 11 trainee endoscopists (cohort 2). All but one participant finished ELCCE training within 7 weeks. In step 6, accuracy ranged from 53 to 98 % and was not impacted by step 2 pretest scores. The average CCAT scores significantly increased between step 2 pretest and step 7 in both cohorts, from 42 ± 18 % to 79 ± 15 % in cohort 1 (p = 0.0004), and from 52 ± 15 % to 79 ± 14 % in cohort 2 (p = 0.0003). ELCCE is useful and effective for improving CCE reading competence.

  5. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    Science.gov (United States)

    2015-01-01

    Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no

  6. Quantitative analysis of patients with celiac disease by video capsule endoscopy: A deep learning method.

    Science.gov (United States)

    Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing

    2017-06-01

    Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Wireless capsule endoscopy of the small bowel: development, testing, and first human trials

    Science.gov (United States)

    Swain, Paul; Iddan, Gavriel J.; Meron, Gavriel; Glukhovsky, Arkady

    2001-01-01

    Small bowel endoscopy with existing endoscopes is limited by problems of discomfort and the technical difficulty of advancing far into the small-bowel. Our aim has been to develop and test wireless capsule endoscopy. Wireless endoscopes, in the form of capsules (11 x 33 mm), were constructed by Given Imaging. These were powered by silver oxide batteries and each contained a CMOS imaging chip and miniature processor, white light emitting diodes (LEDs), a short focal length lens, and a miniature transmitter and antenna. Two video frames per second were transmitted, using radio-frequency (approx. 410 MHz), to an array of aerials attached to the body. The array of aerials can also be used to calculate the position of the capsule in the body. The images were stored on a portable recorder carried on a belt and subsequently downloaded for analysis. The batteries allow more than 5 hours of recording, although the capsule generally passes through the whole small bowel in under two hours. Clear video images of the human bowel were recorded from the pylorus to the caecum. Wireless endoscopy, for the first time, allows painless optical imaging of the whole of the small bowel.

  8. A primary intestinal lymphangiectasia patient diagnosed by capsule endoscopy and confirmed at surgery: a case report.

    Science.gov (United States)

    Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao

    2007-04-21

    Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination.

  9. Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy

    Science.gov (United States)

    Rukundo, Olivier

    2018-04-01

    This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.

  10. Obscure gastrointestinal bleeding: difficulties in comparing CT enterography and video capsule endoscopy

    International Nuclear Information System (INIS)

    Soyer, Philippe

    2012-01-01

    A paper reports the results of a retrospective study that was designed to evaluate the potential role of video capsule endoscopy (VCE) in elucidating the cause of bleeding in patients with obscure gastrointestinal bleeding (OGIB) for whom CT enterography was negative. The authors highlight the limitations of dual-phase CT enterography for the detection of flat lesions of the small bowel such as ulcers, angiodysplasias or arteriovenous malformations, and confirm the superiority of VCE for the detection of this category of lesions. This commentary discusses some of the issues raised. Key Points circle Video capsule endoscopy surpasses CT enterography in detecting flat small bowel lesions. circle Retrospective VCE and CT enterography findings in obscure bleeding need further evaluation. circle A fair and unbiased comparison of the two investigations is still needed. (orig.)

  11. Small bowel involvement documented by capsule endoscopy in Churg-Strauss syndrome.

    Science.gov (United States)

    Beye, Birane; Lesur, Gilles; Claude, Pierre; Martzolf, Lionel; Kieffer, Pierre; Sondag, Daniel

    2015-01-01

    Churg-Strauss syndrome is a small and medium vessel vasculitis and is also known as allergic granulomatous angiitis. Gastrointestinal involvement is common in patients with Churg-Strauss syndrome (20-50%). The most common symptoms are abdominal pain, diarrhoea and occasionally gastrointestinal bleeding and perforation. We present a case of Churg-Strauss syndrome with small bowel lesions documented by video capsule endoscopy.

  12. Detection of active bleeding from gastric antral vascular ectasia by capsule endoscopy

    OpenAIRE

    Ohira, Tetsuya; Hokama, Akira; Kinjo, Nagisa; Nakamoto, Manabu; Kobashigawa, Chiharu; Kise, Yuya; Yamashiro, Satoshi; Kinjo, Fukunori; Kuniyoshi, Yukio; Fujita, Jiro

    2013-01-01

    Gastric antral vascular ectasia (GAVE) has been recognized as one of the important causes of occult and obscure gastrointestinal bleeding. The diagnosis is typically made based on the characteristic endoscopic features, including longitudinal row of flat, reddish stripes radiating from the pylorus into the antrum that resemble the stripes on a watermelon. These appearances, however, can easily be misinterpreted as moderate to severe gastritis. Although it is believed that capsule endoscopy (C...

  13. Wireless Capsule Endoscopy Detects Meckel’s Diverticulum in a Child with Unexplained Intestinal Blood Loss

    Directory of Open Access Journals (Sweden)

    I. Xinias

    2012-10-01

    Full Text Available Meckel’s diverticulum (MD is the most common congenital anomaly of the gastrointestinal (GI tract, affecting about 2% of the population. Most cases of Meckel’s diverticula are asymptomatic. The diagnosis of symptomatic MD is often difficult to make. We report the case of an 8-year-old boy who presented with GI bleeding due to MD. The diagnostic difficulties after an initial negative endoscopic evaluation and the diagnostic value of the various endoscopic procedures are discussed. The patient had suffered from bright red stools for 20 h before hospital admission. GI scintigraphy with 99mTc-Na-pertechnetate was negative for heterotopic gastric tissue in the small bowel area. Colonoscopy performed in order to exclude Crohn’s disease was also negative. He was placed on ranitidine at a dose of 6 mg/kg body weight twice daily. The patient remained asymptomatic over a period of 6 months before he was readmitted due to macroscopic rectal bleeding. Upper endoscopy and colonoscopy used to investigate the source of bleeding showed normal macroscopic findings. Radiolabeling of blood constituents with 99mTc on delayed imaging showed radionucleotide concentration in the ascending and transverse colon suggestive of a lesion in the ileocecal area. Further investigation with the use of wireless capsule endoscopy revealed a MD. Wireless capsule endoscopy may thus be indicated for patients with GI blood loss when other diagnostic methods, such as upper and lower endoscopy and colonoscopy, have failed to identify the source of bleeding.

  14. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy. PMID:20811612

  15. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Directory of Open Access Journals (Sweden)

    Pedro Figueiredo

    2010-01-01

    Full Text Available Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD. Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%. The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  16. Small-bowel capsule endoscopy in patients with suspected Crohn's disease-diagnostic value and complications.

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  17. On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy

    Science.gov (United States)

    Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.

    2011-03-01

    Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.

  18. Capsule endoscopy for the detection of oesophageal mucosal disorders: a comparison of two different ingestion protocols.

    Science.gov (United States)

    De Jonge, Pieter J F; Van Eijck, Brechje C; Geldof, Han; Bekkering, Frank C; Essink-Bot, Marie-Louise; Polinder, Suzanne; Kuipers, Ernst J; Siersema, Peter D

    2008-01-01

    To assess the accuracy of a new ingestion protocol for capsule endoscopy (CE) in evaluating patients with gastro-oesophageal reflux disease (GORD). Oesophago-gastroduodenoscopy (OGD) was performed 1 week prior to CE. The first 28 subjects swallowed the capsule following the original ingestion protocol (OIP) and the subsequent 30 subjects following a simplified ingestion protocol (SIP). CE videos were reviewed by two independent investigators who were blinded to the OGD findings. Of 48 patients included, 24 were diagnosed with reflux oesophagitis (67% male, mean age 49.5+/-13 years) and 24 with Barrett oesophagus (BO) (88% male, 55.6+/-10 years) by OGD. In addition, 10 asymptomatic healthy controls (50% male, 45.8+/-7.1 years) were included. Oesophageal transit time was faster in patients using the SIP compared to the OIP (126+/-26 s versus 214+/-33; p=0.04). Complete evaluation of the Z-line was possible in 19/28 (68%) of the OIPs compared to 28/30 (93%) of the SIPs (p=0.04). Sensitivity for detecting any oesophageal abnormality was higher in the SIP group than in the OIP group (97% versus 89%; p=0.11). Overall, CE detected oesophagitis in 22/24 patients (sensitivity, 92%; specificity, 88%) and BO in 23/24 patients (sensitivity, 96%; specificity, 91%). Furthermore, 41/44 (93%) preferred CE over OGD and experienced less discomfort and pain during CE. CE is an accurate method for detecting mucosal oesophageal abnormalities. The new ingestion protocol improves the visualization of the Z-line, which is likely to increase the diagnostic yield of CE.

  19. Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract.

    Science.gov (United States)

    Liu, Gang; Yan, Guozheng; Zhu, Bingquan; Lu, Li

    2016-11-01

    In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.

  20. Application of wireless power transmission systems in wireless capsule endoscopy: an overview.

    Science.gov (United States)

    Basar, Md Rubel; Ahmad, Mohd Yazed; Cho, Jongman; Ibrahim, Fatimah

    2014-06-19

    Wireless capsule endoscopy (WCE) is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB). To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE) units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT) system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.

  1. Time Series Analysis of the Effectiveness and Safety of Capsule Endoscopy between the Premarketing and Postmarketing Settings: A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Kazuo Iijima

    Full Text Available Clinical studies for assessing the effectiveness and safety in a premarketing setting are conducted under time and cost constraints. In recent years, postmarketing data analysis has been given more attention. However, to our knowledge, no studies have compared the effectiveness and the safety between the pre- and postmarketing settings. In this study, we aimed to investigate the importance of the postmarketing data analysis using clinical data.Studies on capsule endoscopy with rich clinical data in both pre- and postmarketing settings were selected for the analysis. For effectiveness, clinical studies published before October 10, 2015 comparing capsule endoscopy and conventional flexible endoscopy measuring the detection ratio of obscure gastrointestinal bleeding were selected (premarketing: 4 studies and postmarketing: 8 studies from PubMed (MEDLINE, Cochrane Library, EMBASE and Web of Science. Among the 12 studies, 5 were blinded and 7 were non-blinded. A time series meta-analysis was conducted. Effectiveness (odds ratio decreased in the postmarketing setting (premarketing: 5.19 [95% confidence interval: 3.07-8.76] vs. postmarketing: 1.48 [0.81-2.69]. The change in odds ratio was caused by the increase in the detection ratio with flexible endoscopy as the control group. The efficacy of capsule endoscopy did not change between pre- and postmarketing settings. Heterogeneity (I2 increased in the postmarketing setting because of one study. For safety, in terms of endoscope retention in the body, data from the approval summary and adverse event reports were analyzed. The incidence of retention decreased in the postmarketing setting (premarketing: 0.75% vs postmarketing: 0.095%. The introduction of the new patency capsule for checking the patency of the digestive tract might contribute to the decrease.Effectiveness and safety could change in the postmarketing setting. Therefore, time series meta-analyses could be useful to continuously monitor the

  2. Detection of active bleeding from gastric antral vascular ectasia by capsule endoscopy

    Science.gov (United States)

    Ohira, Tetsuya; Hokama, Akira; Kinjo, Nagisa; Nakamoto, Manabu; Kobashigawa, Chiharu; Kise, Yuya; Yamashiro, Satoshi; Kinjo, Fukunori; Kuniyoshi, Yukio; Fujita, Jiro

    2013-01-01

    Gastric antral vascular ectasia (GAVE) has been recognized as one of the important causes of occult and obscure gastrointestinal bleeding. The diagnosis is typically made based on the characteristic endoscopic features, including longitudinal row of flat, reddish stripes radiating from the pylorus into the antrum that resemble the stripes on a watermelon. These appearances, however, can easily be misinterpreted as moderate to severe gastritis. Although it is believed that capsule endoscopy (CE) is not helpful for the study of the stomach with its large lumen, GAVE can be more likely to be detected at CE rather than conventional endoscopy. CE can be regarded as “physiologic” endoscopy, without the need for gastric inflation and subsequent compression of the vasculature. The blood flow of the ecstatic vessels may be diminished in an inflated stomach. Therefore, GAVE may be prominent in CE. We herein describe a case of active bleeding from GAVE detected by CE and would like to emphasize a possibility that CE can improve diagnostic yields for GAVE. PMID:23515703

  3. Physical activity during video capsule endoscopy correlates with shorter bowel transit time.

    Science.gov (United States)

    Stanich, Peter P; Peck, Joshua; Murphy, Christopher; Porter, Kyle M; Meyer, Marty M

    2017-09-01

     Video capsule endoscopy (VCE) is limited by reliance on bowel motility for propulsion, and lack of physical activity has been proposed as a cause of incomplete studies. Our aim was to prospectively investigate the association between physical activity and VCE bowel transit.  Ambulatory outpatients receiving VCE were eligible for the study. A pedometer was attached at the time of VCE ingestion and step count was recorded at the end of the procedure. VCE completion was assessed by logistic regression models, which included step count (500 steps as one unit). Total transit time was analyzed by Cox proportional hazards models. The hazard ratios (HR) with 95 % confidence interval (CI) indicated the "hazard" of completion, such that HRs > 1 indicated a reduced transit time.  A total of 100 patients were included. VCE was completed in 93 patients (93 %). The median step count was 2782 steps. Step count was not significantly associated with VCE completion (odds ratio 1.45, 95 %CI 0.84, 2.49). Pedometer step count was significantly associated with shorter total, gastric, and small-bowel transit times (HR 1.09, 95 %CI 1.03, 1.16; HR 1.05, 95 %CI 1.00, 1.11; HR 1.07, 95 %CI 1.01, 1.14, respectively). Higher body mass index (BMI) was significantly associated with VCE completion (HR 1.87, 95 %CI 1.18, 2.97) and shorter bowel transit times (HR 1.05, 95 %CI 1.02, 1.08).  Increased physical activity during outpatient VCE was associated with shorter bowel transit times but not with study completion. In addition, BMI was a previously unreported clinical characteristic associated with VCE completion and should be included as a variable of interest in future studies.

  4. Video capsule endoscopy after bariatric and gastric surgery: oral ingestion is associated with satisfactory completion rate.

    Science.gov (United States)

    Stanich, Peter P; Kleinman, Bryan; Porter, Kyle M; Meyer, Marty M

    2015-01-01

    To investigate the outcomes of video capsule endoscopy (VCE) performed on patients after bariatric and gastric surgery with a focus on delivery method (oral ingestion or endoscopic placement). There is minimal published data regarding the use of VCE in patients after bariatric and gastric surgery and the optimal delivery method is unknown. Retrospective case series of patients with bariatric or gastric surgery undergoing VCE in a tertiary care center over 3 years. Outcomes of interest were completion of the procedure and bowel transit times. Twenty-three patients met study criteria. They underwent 24 VCE in the study period, with 13/16 (81.3%; 95% CI, 54%-96%) completed to the colon after oral ingestion and 5/8 (62.5%; 95% CI, 24%-91%) completed after endoscopic deployment. The median gastric transit time after oral ingestion was 440) (P=0.48). There were no instances of capsule retention. Oral ingestion of VCE resulted in a satisfactory completion rate with rapid gastric transit after bariatric and gastric surgery. There were no capsule retention events. Given this and the favorable risk and cost profile, oral ingestion should be favored over endoscopic placement in this patient population.

  5. Determination of anthelmintic efficacy against Toxocara canis in dogs by use of capsule endoscopy.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Bowman, Dwight D

    2015-09-15

    Industry guidelines for anthelmintic testing call for postmortem inspection of animals to verify treatment efficacy. A previous study showed that capsule endoscopy (CE) can be performed on dogs in vivo to quantify hookworms in the small intestine. Adoption of a minimally invasive procedure such as this could reduce the need for necropsy in efficacy trials. The present study employed CE to enumerate Toxocara canis in dogs, with two main goals: to determine if multiple capsule examinations improves the accuracy of worm counts compared to a single examination, and to establish if the efficacy of an anthelmintic compound is the same whether calculated using CE or necropsy data. To avoid needless animal sacrifice, the study was carried out on beagle dogs already in a product development trial with a planned terminal endpoint. Dogs were infected by oral inoculation with T. canis eggs. Untreated control dogs (n=8) were evaluated by CE three times while dogs treated with test compounds (3 groups of 4) were examined only once. Utilizing either the average count or just the last complete capsule examination, a robust correlation was found between CE and postmortem numbers (r=0.94, p<0.001). Calculated anthelmintic efficacy was essentially identical for the two enumeration methods, ranging from 94% to 100% for the three research compounds. CE may therefore be a viable alternative to necropsy for T. canis parasiticide trials. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Domperidone prolongs oral to duodenal transit time in video capsule endoscopy.

    Science.gov (United States)

    Mcfarlane, Michael; Liu, B; Nwokolo, C

    2018-04-01

    Domperidone is thought to accelerate gastric emptying via D2 receptor antagonism at the gastro-oesophageal and gastro-duodenal junctions. Listed in the BNF as a prokinetic anti-emetic, it has been used in video capsule endoscopy (VCE) to accelerate capsule delivery to the small intestine. We audited VCEs performed at UHCW from 2011, when as standard practice, domperidone was given pre-VCE, to 2012, after its discontinuation due to doubts about its effectiveness. Thirty-one patients received oral domperidone 20 mg pre-VCE. Thirty-three patients underwent VCE without domperidone pre-treatment. After 2 h, if the capsule remained intra-gastric, gastroscopy-assisted duodenal delivery was performed. Data was analysed using Mann-Whitney testing. Median oro-duodenal transit was 13 and 30 min in the untreated and domperidone groups, respectively (p = 0.01). Median oro-caecal transit was 242 and 267 min in the untreated and domperidone groups, respectively (p = 0.02). No difference in duodenal-caecal transit was seen (p = 0.60). Six percent of untreated and 13% of domperidone VCEs required gastroscopy-assisted duodenal capsule delivery (p = 0.65). Unexpectedly domperidone delayed VCE gastric transit. Most studies on domperidone prokinetic effects have been in diabetic gastroparesis, demonstrating that domperidone can achieve good symptomatic relief, but with mixed results for gastric emptying. Our study suggests that any antiemetic effects of domperidone are not mediated through accelerated gastric transit.

  7. Primary intestinal lymphangiectasia: A rare cause of diarrhea in adults diagnosed by capsule endoscopy and double balloon enteroscopy

    Directory of Open Access Journals (Sweden)

    Varun Gupta

    2014-01-01

    Full Text Available Primary intestinal lymphangiectasia (PIL or Waldmann′s disease is a rare protein-losing enteropathy presenting with diarrhea. The etiology and prevalence of PIL remain unknown. <200 cases have been reported in the literature so far. Diagnosis of intestinal lymphangiectasia is difficult as there are no serological or radiological tests available. Small bowel imaging modalities like capsule endoscopy and double balloon enteroscopy have increased the chances of diagnosis of PIL due to direct visualization of small bowel. Diagnosis is confirmed by characteristic histopathological finding, which includes dilated intestinal lymphatics with broadened villi of the small bowel. We report a case of a patient with chronic diarrhea who was extensively worked up before he was finally diagnosed to have PIL involving the small bowel by performing balloon enteroscopy-guided biopsy.

  8. Tumor recognition in wireless capsule endoscopy images using textural features and SVM-based feature selection.

    Science.gov (United States)

    Li, Baopu; Meng, Max Q-H

    2012-05-01

    Tumor in digestive tract is a common disease and wireless capsule endoscopy (WCE) is a relatively new technology to examine diseases for digestive tract especially for small intestine. This paper addresses the problem of automatic recognition of tumor for WCE images. Candidate color texture feature that integrates uniform local binary pattern and wavelet is proposed to characterize WCE images. The proposed features are invariant to illumination change and describe multiresolution characteristics of WCE images. Two feature selection approaches based on support vector machine, sequential forward floating selection and recursive feature elimination, are further employed to refine the proposed features for improving the detection accuracy. Extensive experiments validate that the proposed computer-aided diagnosis system achieves a promising tumor recognition accuracy of 92.4% in WCE images on our collected data.

  9. Capsule Endoscopy for Ileitis with Potential Involvement of Other Sections of the Small Bowel

    Directory of Open Access Journals (Sweden)

    Hyun Seok Lee

    2016-01-01

    Full Text Available Ileitis is defined as inflammation of the ileum. This condition includes ulcers, aphthous ulcers, erosions, and nodular or erythematous mucosa. Various etiologies are associated with ileitis. Crohn’s disease, ulcerative colitis, medications such as nonsteroidal anti-inflammatory drugs, infectious conditions, neoplasms, infiltrative disorders, vasculitides, spondyloarthritis, endometriosis, and radiation therapy-related conditions involve the ileum. However, the differential diagnosis of terminal ileitis can be difficult in many cases. Video capsule endoscopy (VCE has become a useful tool for the diagnosis of a variety of small bowel lesions. This review describes each of the various conditions associated with ileitis and the diagnostic value of VCE for ileitis, which may help identify and evaluate these conditions in clinical practice. Based on the information provided by VCE, a definitive diagnosis could be made using the patients’ medical history, clinical course, laboratory and ileocolonoscopic findings, radiologic imaging findings, and histologic findings.

  10. Colon Capsule Endoscopy: Where Are We and Where Are We Going

    Directory of Open Access Journals (Sweden)

    Yoo Min Han

    2016-09-01

    Full Text Available Colon capsule endoscopy (CCE is a noninvasive technique for diagnostic imaging of the colon. It does not require air inflation or sedation and allows minimally invasive and painless colonic evaluation. The role of CCE is rapidly evolving; for example, for colorectal screening (colorectal cancer [CRC] in average-risk patients, in patients with an incomplete colonoscopy, in patients refusing a conventional colonoscopy, and in patients with contraindications for conventional colonoscopy. In this paper, we comprehensively review the technical characteristics and procedure of CCE and compare CCE with conventional methods such as conventional colonoscopy or computed tomographic colonography. Future expansion of CCE in the area of CRC screening for the surveillance of polyps and adenomatous lesions and for assessment of inflammatory bowel disease is also discussed.

  11. Wireless capsule endoscopy for diagnosis of acute intestinal graft-versus-host disease.

    Science.gov (United States)

    Neumann, Susanne; Schoppmeyer, Konrad; Lange, Thoralf; Wiedmann, Marcus; Golsong, Johannes; Tannapfel, Andrea; Mossner, Joachim; Niederwieser, Dietger; Caca, Karel

    2007-03-01

    The small intestine is the most common location of intestinal graft-versus-host disease (GVHD). EGD with duodenal biopsies yields the highest diagnostic sensitivity, but the jejunum and ileum are not accessible by regular endoscopy. In contrast, wireless capsule endoscopy (WCE) is a noninvasive imaging procedure offering complete evaluation of the small intestine. The objective was to compare the diagnostic value of EGD, including biopsies, with the results of WCE in patients with acute intestinal symptoms who received allogeneic blood stem cell transplantation and to analyze the appearance and distribution of acute intestinal GVHD lesions in these patients. An investigator-blinded, single-center prospective study. Patients with acute intestinal symptoms after allogeneic stem cell transplantation underwent both EGD and WCE within 24 hours. Clinical data were recorded during 2 months of follow-up. Fourteen consecutive patients with clinical symptoms of acute intestinal GVHD were recruited. In 1 patient, the capsule remained in the stomach and was removed endoscopically. In 7 of 13 patients who could be evaluated, acute intestinal GVHD was diagnosed by EGD with biopsies, but 3 of these would have been missed by EGD alone. In all 7 patients with histologically confirmed acute intestinal GVHD, WCE revealed typical signs of GVHD. Lesions were scattered throughout the small intestine, but were most accentuated in the ileum. This study had a small number of patients. WCE, which is less invasive than EGD with biopsies, showed a comparable sensitivity and a high negative predictive value for diagnosing acute intestinal GVHD. It may be helpful to avoid repeated endoscopic procedures in patients who have undergone stem cell transplantation.

  12. [Design of extracorporeal apparatus of capsule endoscopy based on ARM+FPGA].

    Science.gov (United States)

    Wang, Shenghua; Zhang, Sijie; Wang, Yue; Wang, Zhenxing

    2011-10-01

    Considering that the patients would bear the annoyance of fixed posture for long time when they are examined with gastrointestinal wireless endoscopy, even though portable devices have been developed, the treatments still depend on PC so much, we proposed an embedded solution based on ARM + FPGA. It used embedded ARM9 S3C2440 as processor core, collected images from digestive tract through capsule endoscopy which can be swallowed down there, and wirelessly transferred these images to the receiving system, then used video decoder chip SAA7114H for analog of NTSC video image decode. And under FPGA's logic controlling, effective digital video signal was transferred to S3C2440 for further treatment. Finally within the embedded Linux environment, we programmed the visual user interfaces using the QT/Embedded, realizing the offline record of the real-time video images of digestive tract portable and preferences. It can make patients move more freely and even without PC when examining. In addition, the method greatly improves the efficiency of the doctor, and is more intelligent and with more humane nature.

  13. Obscure gastrointestinal bleeding: preliminary comparison of 64-section CT enteroclysis with video capsule endoscopy

    International Nuclear Information System (INIS)

    Khalife, Samer; Vahedi, Kouroche; Dray, Xavier; Marteau, Philippe; Soyer, Philippe; Hamzi, Lounis; Place, Vinciane; Boudiaf, Mourad; Alatawi, Abdullah

    2011-01-01

    To retrospectively compare the diagnostic capabilities of 64-section CT enteroclysis with those of video capsule endoscopy (VCE) to elucidate the cause of obscure gastrointestinal bleeding. Thirty-two patients who had 64-section CT enteroclysis and VCE because of obscure gastrointestinal bleeding were included. Imaging findings were compared with those obtained at double balloon endoscopy, surgery and histopathological analysis, which were used as a standard of reference. Concordant findings were found in 22 patients (22/32; 69%), including normal findings (n = 13), tumours (n = 7), lymphangiectasia (n = 1) and inflammation (n = 1), and discrepancies in 10 patients (10/32; 31%), including ulcers (n = 3), angioectasias (n = 2), tumours (n = 2) and normal findings (n = 3). No statistical difference in the proportions of abnormal findings between 64-section CT enteroclysis (11/32; 34%) and VCE (17/32, 53%) (P = 0.207) was found. However, 64-section CT enteroclysis helped identify tumours not detected at VCE (n = 2) and definitely excluded suspected tumours (n = 3) because of bulges at VCE. Conversely, VCE showed ulcers (n = 3) and angioectasias (n = 2) which were not visible at 64-section CT enteroclysis. Our results suggest that 64-section CT enteroclysis and VCE have similar overall diagnostic yields in patients with obscure gastrointestinal bleeding. However, the two techniques are complementary in this specific population. (orig.)

  14. In-to-out body path loss for wireless radio frequency capsule endoscopy in a human body.

    Science.gov (United States)

    Vermeeren, G; Tanghe, E; Thielens, A; Martens, L; Joseph, W

    2016-08-01

    Physical-layer characterization is important for design of in-to-out body communication for wireless body area networks (WBANs). This paper numerically investigates the path loss of an in-to-out body radio frequency (RF) wireless link between an endoscopy capsule and a receiver outside the body using a 3D electromagnetic solver. A spiral antenna in the endoscopy capsule is tuned to operate in the Medical Implant Communication Service (MICS) band at 402 MHz, accounting for the properties of the human body. The influence of misalignment, rotation of the capsule, and human body model are investigated. Semi-empirical path loss models for various homogeneous tissues and 3D realistic human body models are provided for manufacturers to evaluate the performance of in-to-out-body WBAN systems.

  15. Thermo-mechanical actuator-based miniature tagging module for localization in capsule endoscopy

    Science.gov (United States)

    Chandrappan, Jayakrishnan; Ruiqi, Lim; Su, Nandar; Yen Yi, Germaine Hoe; Vaidyanathan, Kripesh

    2011-04-01

    Capsule endoscopy is a frontline medical diagnostic tool for the gastro intestinal tract disorders. During diagnosis, efficient localization techniques are essential to specify a pathological area that may require further diagnosis or treatment. This paper presents the development of a miniature tagging module that relies on a novel concept to label the region of interest and has the potential to integrate with a capsule endoscope. The tagging module is a compact thermo-mechanical actuator loaded with a biocompatible micro tag. A low power microheater attached to the module serves as the thermal igniter for the mechanical actuator. At optimum temperature, the actuator releases the micro tag instantly and penetrates the mucosa layer of a GI tract, region of interest. Ex vivo animal trials are conducted to verify the feasibility of the tagging module concept. X-ray imaging is used to detect the location of the micro tag embedded in the GI tract wall. The method is successful, and radiopaque micro tags can provide valuable pre-operative position information on the infected area to facilitate further clinical procedures.

  16. Comparison of Capsule Endoscopy Findings to Subsequent Double Balloon Enteroscopy: A Dual Center Experience

    Directory of Open Access Journals (Sweden)

    Amandeep S. Kalra

    2015-01-01

    Full Text Available Background. There has been a growing use of both capsule endoscopy (CE and double balloon enteroscopy (DBE to diagnose and treat patients with obscure gastrointestinal blood loss and suspected small bowel pathology. Aim. To compare and correlate sequential CE and DBE findings in a large series of patients at two tertiary level hospitals in Wisconsin. Methods. An IRB approved retrospective study of patients who underwent sequential CE and DBE, at two separate tertiary care academic centers from May 2007 to December 2011, was performed. Results. 116 patients were included in the study. The mean age ± SD was 66.6 ± 13.2 years. There were 56% males and 43.9% females. Measure of agreement between prior capsule and DBE findings was performed using kappa statistics, which gave kappa value of 0.396 with P<0.001. Also contingency coefficient was calculated and was found to be 0.732 (P<0.001. Conclusions. Our study showed good overall agreement between DBE and CE. Findings of angioectasia had maximum agreement of 69%.

  17. A video wireless capsule endoscopy system powered wirelessly: design, analysis and experiment

    International Nuclear Information System (INIS)

    Pan, Guobing; Chen, Jiaoliao; Xin, Wenhui; Yan, Guozheng

    2011-01-01

    Wireless capsule endoscopy (WCE), as a relatively new technology, has brought about a revolution in the diagnosis of gastrointestinal (GI) tract diseases. However, the existing WCE systems are not widely applied in clinic because of the low frame rate and low image resolution. A video WCE system based on a wireless power supply is developed in this paper. This WCE system consists of a video capsule endoscope (CE), a wireless power transmission device, a receiving box and an image processing station. Powered wirelessly, the video CE has the abilities of imaging the GI tract and transmitting the images wirelessly at a frame rate of 30 frames per second (f/s). A mathematical prototype was built to analyze the power transmission system, and some experiments were performed to test the capability of energy transferring. The results showed that the wireless electric power supply system had the ability to transfer more than 136 mW power, which was enough for the working of a video CE. In in vitro experiments, the video CE produced clear images of the small intestine of a pig with the resolution of 320 × 240, and transmitted NTSC format video outside the body. Because of the wireless power supply, the video WCE system with high frame rate and high resolution becomes feasible, and provides a novel solution for the diagnosis of the GI tract in clinic

  18. An artificial neural network architecture for non-parametric visual odometry in wireless capsule endoscopy

    International Nuclear Information System (INIS)

    Dimas, George; Iakovidis, Dimitris K; Karargyris, Alexandros; Ciuti, Gastone; Koulaouzidis, Anastasios

    2017-01-01

    Wireless capsule endoscopy is a non-invasive screening procedure of the gastrointestinal (GI) tract performed with an ingestible capsule endoscope (CE) of the size of a large vitamin pill. Such endoscopes are equipped with a usually low-frame-rate color camera which enables the visualization of the GI lumen and the detection of pathologies. The localization of the commercially available CEs is performed in the 3D abdominal space using radio-frequency (RF) triangulation from external sensor arrays, in combination with transit time estimation. State-of-the-art approaches, such as magnetic localization, which have been experimentally proved more accurate than the RF approach, are still at an early stage. Recently, we have demonstrated that CE localization is feasible using solely visual cues and geometric models. However, such approaches depend on camera parameters, many of which are unknown. In this paper the authors propose a novel non-parametric visual odometry (VO) approach to CE localization based on a feed-forward neural network architecture. The effectiveness of this approach in comparison to state-of-the-art geometric VO approaches is validated using a robotic-assisted in vitro experimental setup. (paper)

  19. An artificial neural network architecture for non-parametric visual odometry in wireless capsule endoscopy

    Science.gov (United States)

    Dimas, George; Iakovidis, Dimitris K.; Karargyris, Alexandros; Ciuti, Gastone; Koulaouzidis, Anastasios

    2017-09-01

    Wireless capsule endoscopy is a non-invasive screening procedure of the gastrointestinal (GI) tract performed with an ingestible capsule endoscope (CE) of the size of a large vitamin pill. Such endoscopes are equipped with a usually low-frame-rate color camera which enables the visualization of the GI lumen and the detection of pathologies. The localization of the commercially available CEs is performed in the 3D abdominal space using radio-frequency (RF) triangulation from external sensor arrays, in combination with transit time estimation. State-of-the-art approaches, such as magnetic localization, which have been experimentally proved more accurate than the RF approach, are still at an early stage. Recently, we have demonstrated that CE localization is feasible using solely visual cues and geometric models. However, such approaches depend on camera parameters, many of which are unknown. In this paper the authors propose a novel non-parametric visual odometry (VO) approach to CE localization based on a feed-forward neural network architecture. The effectiveness of this approach in comparison to state-of-the-art geometric VO approaches is validated using a robotic-assisted in vitro experimental setup.

  20. Practice patterns and clinical significance of use of capsule endoscopy in suspected and established Crohn's disease

    Directory of Open Access Journals (Sweden)

    Yonghyun Kim

    2017-10-01

    Full Text Available Background/Aims: Although the role of capsule endoscopy (CE in Crohn's disease (CD has expanded, CE is not used routinely for diagnosing and evaluating CD in Korea. We aimed to investigate current patterns of practice and evaluate the clinical significance of the use of CE in CD in Korean patients.Methods: Among 651 CE procedures performed for various indications, we retrospectively analyzed the medical records of patients who underwent CE in 57 cases of suspected CD (sCD and 14 cases of established CD (eCD.Results: In the sCD group, CE was most commonly used for the initial diagnosis of CD (54.4%. Capsule retention was found in only 1 patient in the eCD group (1/71, 1.4%. In the sCD group, 28.1% of patients were diagnosed with CD on the basis of CE findings; other diseases diagnosed included tuberculous enteritis (7.0%, non-steroidal anti-inflammatory drug-induced enteropathy (5.3%, and other enteritis (17.5%. Only 11.5% of patients with eCD (14/122 underwent CE. The indication for CE in the 14 patients with eCD was to assess disease extent and activity. The overall diagnostic yield of CE was 59.7%. Therapeutic strategies were changed in 70.2% of patients in the sCD group and 50% of those in the eCD group based on CE findings.Conclusions: In clinical practice, CE was most commonly indicated for the initial diagnosis of CD and was not generally performed in patients with eCD. CE appears to be an effective diagnostic modality for evaluating sCD and is useful for determining therapeutic strategies for patients with sCD and those with eCD.

  1. A simplified ingestion procedure for esophageal capsule endoscopy: initial evaluation in healthy volunteers.

    Science.gov (United States)

    Gralnek, I M; Rabinovitz, R; Afik, D; Eliakim, R

    2006-09-01

    Initial studies on esophageal capsule endoscopy (PillCam ESO) reported excellent sensitivity and specificity, but these were followed by mixed results in several subsequent studies, probably due to deviations from the recommended ingestion protocol and the inconvenience of capsule ingestion in the supine position. The aim of this study was therefore to test a simplified ingestion procedure (SIP) for PillCam ESO. Using a cross-over study design, the SIP was prospectively compared with the original ingestion procedure for PillCam ESO in 24 healthy volunteers (15 men, nine women; mean age 44, range 27 - 70) and evaluated for: bubbles/saliva interference at the Z-line, Z-line circumferential visualization (quadrants), and convenience and ease of the ingestion procedure. All Rapid 4 videos were reviewed in a randomized manner and read by an experienced PillCam ESO reader blinded to the ingestion procedure used. It was found that the SIP significantly improved visualization in comparison with the original ingestion procedure, with less interference due to bubbles/saliva observed at the gastroesophageal junction ( P = 0.002) and improved visualization of the Z-line ( P = 0.025). Although the esophageal transit time was significantly faster with the SIP (3 : 45 min vs. 0 : 38 min; P = 0.0001), there were no differences in the number of Z-line frames/images captured. This new, simplified ingestion procedure for PillCam ESO provides significantly improved visualization of the Z-line in healthy volunteers. The overall test characteristics of PillCam ESO using SIP should be tested in patients with esophageal disease.

  2. CHOBS: Color Histogram of Block Statistics for Automatic Bleeding Detection in Wireless Capsule Endoscopy Video.

    Science.gov (United States)

    Ghosh, Tonmoy; Fattah, Shaikh Anowarul; Wahid, Khan A

    2018-01-01

    Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data.

  3. Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning

    Directory of Open Access Journals (Sweden)

    Ümit Akyüz

    2016-01-01

    Full Text Available Background. Colon capsule endoscopy (CCE is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step, 3 different colon preparing regimens were given to 30 patients [Group A: 3 days of liquid diet, sodium phosphate (NaP (90 mL, and NaP enema; Group B: 3 days of liquid diet, 4 L of polyethylene glycol (PEG, and metoclopramide; Group C: 3 days of liquid diet, 4 L of PEG, NaP (45 mL, and bisacodyl after capsule ingestion] (10 patients in each group. The other consecutive 32 patients were cleaned with the best regimen which was NaP + PEG and CCE was performed. The results of CCE were controlled with colonoscopy in 28 patients. Results. Group C had the highest cleaning score, compared with the other groups (2.2±0.4 versus 2.7±0.4 versus 3.7±0.4, p value =0.000. The CCE findings were as follows in 28 patients who were also examined with colonoscopy: polyp (range: 5–10 mm in 6 patients, internal hemorrhoids in 3 patients, angiodysplasia in 1 patient, diverticula in 1 patient, and ulcerative colitis in 1 patient. The sensitivity, specificity, PPV, and NPV of CCE were 100%, 92%, 93%, and 100%, respectively. Conclusions. Low dosage NaP combined with PEG provides optimal bowel preparation for CCE. CCE appears to be a highly sensitive diagnostic modality for detecting colonic pathologies.

  4. Surveillance of FAP: a prospective blinded comparison of capsule endoscopy and other GI imaging to detect small bowel polyps

    Directory of Open Access Journals (Sweden)

    Tescher Paul

    2010-04-01

    Full Text Available Abstract Background Familial adenomatous polyposis (FAP is a hereditary disorder characterized by polyposis along the gastrointestinal tract. Information on adenoma status below the duodenum has previously been restricted due to its inaccessibility in vivo. Capsule Endoscopy (CE may provide a useful adjunct in screening for polyposis in the small bowel in FAP patients. This study aims to evaluate the effectiveness of CE in the assessment of patients with FAP, compared to other imaging modalities for the detection of small bowel polyps. Method 20 consecutive patients with previously diagnosed FAP and duodenal polyps, presenting for routine surveillance of polyps at The Royal Melbourne Hospital were recruited. Each fasted patient initially underwent a magnetic resonance image (MRI of the abdomen, and a barium small bowel follow-through study. Capsule Endoscopy was performed four weeks later on the fasted patient. An upper gastrointestinal side-viewing endoscopy was done one (1 to two (2 weeks after this. Endoscopists and investigators were blinded to results of other investigations and patient history. Results Within the stomach, upper gastrointestinal endoscopy found more polyps than other forms of imaging. SBFT and MRI generally performed poorly, identifying fewer polyps than both upper gastrointestinal and capsule endoscopy. CE was the only form of imaging that identified polyps in all segments of the small bowel as well as the only form of imaging able to provide multiple findings outside the stomach/duodenum. Conclusion CE provides important information on possible polyp development distal to the duodenum, which may lead to surgical intervention. The place of CE as an adjunct in surveillance of FAP for a specific subset needs consideration and confirmation in replication studies. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN12608000616370

  5. Wireless capsule endoscopy and proximal small bowel lesions in Crohn’s disease

    Science.gov (United States)

    Petruzziello, Carmelina; Onali, Sara; Calabrese, Emma; Zorzi, Francesca; Ascolani, Marta; Condino, Giovanna; Lolli, Elisabetta; Naccarato, Paola; Pallone, Francesco; Biancone, Livia

    2010-01-01

    AIM: To investigate the prevalence of proximal small bowel (SB) lesions detected by wireless capsule endoscopy (WCE) in Crohn’s disease (CD). METHODS: WCE was performed in 64 patients: 32 with CD of the distal ileum, and 32 controls with iron-deficiency anemia (IDA) or diarrhea. WCE was performed using the Given SB-WCE, followed by small intestine contrast ultrasonography (SICUS). Findings compatible with CD by using WCE included erosions, aphthoid or deep ulcers, and strictures/stenosis. RESULTS: WCE detected proximal SB lesions in 16/32 (50%) patients (14 aphthoid ulcers, 2 deep ulcers, one stricture), which appeared not to be related to clinical parameters [epigastric pain, age, smoking, non-steroidal anti-inflammatory drugs (NSAIDs), IDA]. Among patients with proximal SB lesions, 6 (37%) were smokers, 3 (19%) NSAID users, 3 (19%) had epigastric pain and 4 (25%) had IDA. SICUS detected proximal SB lesions in 3/32 patients (19%) also showing lesions with WCE. No correlations were observed between proximal SB lesions assessed by WCE or by SICUS (χ2 = 1.5, P = 0.2). CONCLUSION: The use of WCE allows the detection of previously unknown upper SB lesions in a high proportion of patients with a previous diagnosis of CD involving the distal ileum. PMID:20614486

  6. Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy.

    Science.gov (United States)

    Khan, Umair; Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh

    2018-01-01

    In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution.

  7. Small bowel preparations for capsule endoscopy with mannitol and simethicone: a prospective, randomized, clinical trial.

    Science.gov (United States)

    Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na

    2011-04-01

    There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.

  8. Coffee Enema for Preparation for Small Bowel Video Capsule Endoscopy: A Pilot Study

    Science.gov (United States)

    Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang

    2014-01-01

    Coffee enemas are believed to cause dilatation of bile ducts and excretion of bile through the colon wall. Proponents of coffee enemas claim that the cafestol palmitate in coffee enhances the activity of glutathione S-transferase, an enzyme that stimulates bile excretion. During video capsule endoscopy (VCE), excreted bile is one of the causes of poor preparation of the small bowel. This study aimed to evaluate the feasibility and effect of coffee enema for preparation of the small bowel during VCE. In this pilot study, 17 of 34 patients were assigned to the coffee enema plus polyethylene glycol (PEG) 2 L ingestion group, whereas the 17 remaining control patients received 2 L of PEG only. The quality of bowel preparation was evaluated in the two patient groups. Bowel preparations in the proximal segments of small bowel were not differ between two groups. In the mid and distal segments of the small intestine, bowel preparations tend to be better in patients who received coffee enemas plus PEG than in patients who received PEG only. The coffee enema group did not experience any complications or side effects. Coffee enemas may be a feasible option, and there were no clinically significant adverse events related to coffee enemas. More prospective randomized studies are warranted to improve small bowel preparation for VCE. PMID:25136541

  9. Design of a Lossless Image Compression System for Video Capsule Endoscopy and Its Performance in In-Vivo Trials

    Science.gov (United States)

    Khan, Tareq H.; Wahid, Khan A.

    2014-01-01

    In this paper, a new low complexity and lossless image compression system for capsule endoscopy (CE) is presented. The compressor consists of a low-cost YEF color space converter and variable-length predictive with a combination of Golomb-Rice and unary encoding. All these components have been heavily optimized for low-power and low-cost and lossless in nature. As a result, the entire compression system does not incur any loss of image information. Unlike transform based algorithms, the compressor can be interfaced with commercial image sensors which send pixel data in raster-scan fashion that eliminates the need of having large buffer memory. The compression algorithm is capable to work with white light imaging (WLI) and narrow band imaging (NBI) with average compression ratio of 78% and 84% respectively. Finally, a complete capsule endoscopy system is developed on a single, low-power, 65-nm field programmable gate arrays (FPGA) chip. The prototype is developed using circular PCBs having a diameter of 16 mm. Several in-vivo and ex-vivo trials using pig's intestine have been conducted using the prototype to validate the performance of the proposed lossless compression algorithm. The results show that, compared with all other existing works, the proposed algorithm offers a solution to wireless capsule endoscopy with lossless and yet acceptable level of compression. PMID:25375753

  10. VIDEO CAPSULE ENDOSCOPY: A TOOL FOR THE ASSESSMENT OF SMALL BOWEL TRANSIT TIME

    Directory of Open Access Journals (Sweden)

    Reza A Hejazi

    2016-02-01

    Full Text Available Purpose: Video capsule endoscopy (VCE is a procedure that uses a wireless camera to take pictures of the gastrointestinal tract. A wireless motility capsule (WMC of a similar size has been developed, which measures pH, pressure, and temperature, and can be used to assess regional and total gastrointestinal transit times. VCE could also potentially be used as a tool for measuring small bowel transit time (SBTT.Methods: This study was designed to obtain SBTT from VCE and compare it with historical data generated by WMC. Gastric transit time (GTT was also measured. Patients were included if the indication for VCE was either iron deficiency anemia (IDA or overt obscure GI bleed (OOGIB and they did not have any known motility disorder. Results from VCE were also compared in diabetic versus non-diabetic patients. Results: There were a total of 147 VCE studies performed, including 42 for OOGIB and 105 for IDA. Median GTT and SBTT were 0.3 and 3.6 hours, respectively. The overall median GTT and SBTT were 0.3 and 3.6 hours, respectively, in the IDA group compared with 0.3 and 3.4 hours in the OOGIB group. When compared with WMC, the GTT and SBTT were significantly faster in both groups (GTT: 3.6 hours and SBTT: 4.6 hours. The median GTT and SBTT were not significantly different in diabetics versus non-diabetics: (GTT: 17.5 vs. 18.0 minutes (P=0.86 and SBTT: 3.9 hours (237 minutes vs. 3.8 hours (230 minutes, respectively (P=0.90.Conclusion: SBTT as measured using VCE is not significantly different in OOGIB compared with IDA. Both GTT and SBTT are significantly faster as assessed by VCE, which is initiated in the fasting state, compared with WMC measurement, which is initiated after a standard meal. In summary, VCE could potentially be used for measuring SBTT in the fasting state.

  11. Video Capsule Endoscopy: A Tool for the Assessment of Small Bowel Transit Time.

    Science.gov (United States)

    Hejazi, Reza A; Bashashati, Mohammad; Saadi, Mohammed; Mulla, Zuber D; Sarosiek, Irene; McCallum, Richard W; Zuckerman, Marc J

    2016-01-01

    Video capsule endoscopy (VCE) is a procedure that uses a wireless camera to take pictures of the gastrointestinal (GI) tract. A wireless motility capsule (WMC) of a similar size has been developed, which measures pH, pressure, and temperature and can be used to assess regional and total GI transit times. VCE could also potentially be used as a tool for measuring small bowel transit time (SBTT). This study was designed to obtain SBTT from VCE and compare it with historical data generated by WMC. Gastric transit time (GTT) was also measured. Patients were included if the indication for VCE was either iron deficiency anemia (IDA) or overt obscure GI bleed (OOGIB), and they did not have any known motility disorder. Results from VCE were also compared in diabetic vs. non-diabetic patients. There were a total of 147 VCE studies performed, including 42 for OOGIB and 105 for IDA. Median GTT and SBTT were 0.3 and 3.6 h, respectively. The overall median GTT and SBTT were 0.3 and 3.6 h, respectively, in the IDA group compared with 0.3 and 3.4 h in the OOGIB group. When compared with WMC, the GTT and SBTT were significantly faster in both groups (GTT: 3.6 h and SBTT: 4.6 h). The median GTT and SBTT were not significantly different in diabetics vs. non-diabetics [GTT: 17.5 vs. 18.0 min (P = 0.86) and SBTT: 3.9 h (237 min) vs. 3.8 h (230 min), respectively (P = 0.90)]. SBTT as measured using VCE is not significantly different in OOGIB compared with IDA. Both GTT and SBTT are significantly faster as assessed by VCE, which is initiated in the fasting state, compared with WMC measurement, which is initiated after a standard meal. In summary, VCE could potentially be used for measuring SBTT in the fasting state.

  12. Bleeding detection in wireless capsule endoscopy using adaptive colour histogram model and support vector classification

    Science.gov (United States)

    Mackiewicz, Michal W.; Fisher, Mark; Jamieson, Crawford

    2008-03-01

    Wireless Capsule Endoscopy (WCE) is a colour imaging technology that enables detailed examination of the interior of the gastrointestinal tract. A typical WCE examination takes ~ 8 hours and captures ~ 40,000 useful images. After the examination, the images are viewed as a video sequence, which generally takes a clinician over an hour to analyse. The manufacturers of the WCE provide certain automatic image analysis functions e.g. Given Imaging offers in their Rapid Reader software: The Suspected Blood Indicator (SBI), which is designed to report the location in the video of areas of active bleeding. However, this tool has been reported to have insufficient specificity and sensitivity. Therefore it does not free the specialist from reviewing the entire footage and was suggested only to be used as a fast screening tool. In this paper we propose a method of bleeding detection that uses in its first stage Hue-Saturation-Intensity colour histograms to track a moving background and bleeding colour distributions over time. Such an approach addresses the problem caused by drastic changes in blood colour distribution that occur when it is altered by gastrointestinal fluids and allow detection of other red lesions, which although are usually "less red" than fresh bleeding, they can still be detected when the difference between their colour distributions and the background is large enough. In the second stage of our method, we analyse all candidate blood frames, by extracting colour (HSI) and texture (LBP) features from the suspicious image regions (obtained in the first stage) and their neighbourhoods and classifying them using Support Vector Classifier into Bleeding, Lesion and Normal classes. We show that our algorithm compares favourably with the SBI on the test set of 84 full length videos.

  13. Diagnostic role of capsule endoscopy in patients of obscure gastrointestinal bleeding after negative CT enterography

    Directory of Open Access Journals (Sweden)

    Jaswinder Singh Sodhi

    2013-01-01

    Full Text Available Background and Objectives: Computed tomographic enterography (CT-EG has emerged a useful tool for the evaluation of small bowel in patients of obscure gastrointestinal bleeding (OGIB. However, CT-EG may be negative in about 50-60% of patients. We aimed to see the efficacy of capsule endoscopy (CE in patients of OGIB, who had initial negative CT-EG. Materials and Methods: All consecutive patients of OGIB after initial hemodynamic stabilization were subjected to CT-EG. Those having negative CT-EG were further evaluated with CE. Results: Fifty-five patients of OGIB with mean standard deviation age, 52.7 (19.0, range 18-75 years, women 31/55 (56.4% were subjected to CT-EG. Nine (17.6% patients had positive findings on CT-EG, which included mass lesions in six, thickened wall of distal ileal loops, narrowing, and wall enhancement in two and jejunal wall thickening with wall hyperenhancement in one patient. Forty-two patients had negative CT-EG of which 25 underwent CE for further evaluation. CE detected positive findings in 11 of 25 (48% patients which included vascular malformations in three, ulcers in seven, and fresh blood without identifiable source in one. The diagnostic yield of CE in overt OGIB was more compared to occult OGIB ((7/14, 50% vs (4/11, 36.4% P = 0.2 and was higher if performed within 2 weeks of active gastrointestinal (GI bleed (P = 0.08. Conclusions: In conclusion, CE is an additional tool in the evaluation of obscure GI bleed, especially mucosal lesions which can be missed by CT-EG.

  14. Portal hypertensive enteropathy diagnosed by capsule endoscopy and demonstration of the ileal changes after transjugular intrahepatic portosystemic shunt placement: a case report

    Directory of Open Access Journals (Sweden)

    Carella Alessandra

    2011-03-01

    Full Text Available Abstract Introduction Recent data suggest that mucosal abnormalities can occur even in the duodenum, jejunum, and distal ileum of cirrhosis patients. We present a case of portal hypertensive enteropathy in a cirrhosis patient shown by capsule endoscopy and the effect of transjugular intrahepatic portosystemic shunt on the ileal pictures. Case presentation An 83-year-old Caucasian woman was admitted to our hospital for anemia and a positive fecal occult blood test. An upper gastrointestinal endoscopy revealed small varices without bleeding signs and hypertensive gastropathy. Colonoscopy was negative. To rule out any other cause of bleeding, capsule endoscopy was performed; capsule endoscopy revealed severe hyperemia of the jejunum-ileal mucosa with active bleeding. Because of the persistence of anemia and the frequent blood transfusions, not responding to β-blocker drugs or octreotide infusion, a transjugular intrahepatic portosystemic shunt was performed. Anemia improved quickly after the transjugular intrahepatic portosystemic shunt, and no further blood transfusion was necessary in the follow-up. The patient developed portal encephalopathy two months later and was readmitted to our department. We repeated the capsule endoscopy that showed a significant improvement of the gastric and ileal mucosa without any signs of bleeding. Conclusion Hypertensive enteropathy is a rare condition, but it seems more common with the introduction of capsule endoscopy in clinical practice. This case shows that the jejunum can be a source of bleeding in cirrhosis patients, and this is the first demonstration of its resolution after transjugular intrahepatic portosystemic shunt placement.

  15. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases.

    Science.gov (United States)

    Ladas, S D; Triantafyllou, K; Spada, C; Riccioni, M E; Rey, J-F; Niv, Y; Delvaux, M; de Franchis, R; Costamagna, G

    2010-03-01

    These recommendations on video capsule endoscopy, an emerging technology with an impact on the practice of endoscopy, were developed by the European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee. The first draft of each section was prepared by one or two members of the writing team, who were selected as experts on the content of that section on the basis of their published work. They used evidence-based methodology, performing MEDLINE and PubMed literature searches to identify relevant clinical studies. Abstracts from scientific meetings were included only if there was no published full paper on a particular topic. If there was disagreement, the first author of the Guideline made the final decision. Recommendations were graded according to the strength of the supporting evidence. The draft guideline was critically reviewed by all authors and submitted to the ESGE councillors for their critical review before approval of the final document. The ESGE Guidelines Committee acknowledges that this document is based on a critical review of the data available at the time of preparation and that further studies may be needed to clarify some aspects. Moreover, this Guideline may be revised as necessary to account for changes in technology, new data, or other aspects of clinical practice. This document should be regarded as supplying recommendations only to gastroenterologists in providing care to their patients. It is not a set of rules and should not be construed as establishing a legal standard of care, or as encouraging, advocating, requiring, or discouraging any particular treatment. These recommendations must be interpreted according to the clinician's knowledge, expertise, and clinical judgment in the management of individual patients and, if necessary, a course of action that varies from recommendations must be undertaken. Georg Thieme Verlag KG Stuttgart. New York.

  16. The relationship between physical activity level and completion rate of small bowel examination in patients undergoing capsule endoscopy.

    Science.gov (United States)

    Shibuya, Tomoyoshi; Mori, Hiroki; Takeda, Tsutomu; Konishi, Masae; Fukuo, Yuka; Matsumoto, Kenshi; Beppu, Kazuko; Sakamoto, Naoto; Osada, Taro; Nagahara, Akihito; Otaka, Michiro; Ogihara, Tatsuo; Watanabe, Sumio

    2012-01-01

    Capsule endoscopy (CE) allows direct examination of the small bowel in a safe, noninvasive and well-tolerated manner. Nonetheless, experience indicates failure to reach the cecum in 20-30% of patients within the 8 hour battery life. Attempts to improve the completion rate (CR) as defined by reaching the cecum have been unsuccessful. This study was to investigate the relationship between patients' physical activity and CR. Between January 2009 and January 2010, 76 patients (44 men, 32 women; median age 64.5 yr) underwent CE for the diagnosis of small intestinal disorders. Indications for CE were obscure gastrointestinal bleeding/anemia (62 cases), others (14 cases). Patients were divided into an outpatient group (n=23), mild bed rest group (n=35) and strict bed rest group (n=18). For all patients, the average gastric transit time was 65.5 minutes, small bowel transit time was 301.4 minutes and the CR was 86.8%. However, the CR was 100% (23/23) in the outpatient group, an 85.7% (30/35) in the mild bed rest group, and 72.2% (13/18) in the strict bed rest group. The CR increased with physical activity of patients by Cochran-Armitage Trend Test (p=0.009). In multivariate logistic regression analyses, low physical activity was a significant risk factor for failure to reach the cecum during CE examination; adjusted OR: 3.39, 95% CI: 1.01-11.42 (p=0.048). Our observations suggested that increasing physical activity would increase the likelihood of a complete bowel examination by CE. Further, for CE, inconvenient bowel preparations like the use of polyethylene glycol may be avoided.

  17. Meta-analysis shows similar re-bleeding rates among Western and Eastern populations after index video capsule endoscopy.

    Science.gov (United States)

    Tziatzios, Georgios; Gkolfakis, Paraskevas; Hassan, Cesare; Toth, Ervin; Zullo, Angelo; Koulaouzidis, Anastasios; Dimitriadis, George D; Triantafyllou, Konstantinos

    2018-03-01

    Video capsule endoscopy (VCE) is the first-line diagnostic procedure for investigating obscure gastrointestinal bleeding (OGIB). Different re-bleeding rates following index VCE have been reported among Western and Eastern studies. We conducted a comprehensive literature search to identify studies examining re-bleeding rates after VCE for OGIB. Meta-analysis assessed the pooled proportion of re-bleeding events after VCE for OGIB according to study's origin (Western vs. Eastern) and according to the length of follow-up (≥24 months vs. Western and 16 Eastern) studies with 5796 patients. Significant heterogeneity was detected among meta-analyzed studies. Overall, the pooled re-bleeding rate was similar between Western (29%; 95% CI: 23-34) and Eastern (21%; 95% CI: 15-27) populations, irrespective of the length of follow-up. The odds of re-bleeding was significantly higher after positive as compared to negative index VCE in Eastern studies (OR: 1.77; 95% CI: 1.07-2.94). Application of specific treatment after positive index VCE was associated with lower re-bleeding odds in both Western (OR: 0.37; 95% CI: 0.16-0.87) and Eastern (OR: 0.39; 95% CI: 0.21-0.72) populations. Patients undergoing VCE for OGIB have similar re-bleeding rates in the East and the West, regardless of the length of follow-up. However, increased re-bleeding odds after positive index VCE is observed in Eastern studies. Copyright © 2018 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment.

    Directory of Open Access Journals (Sweden)

    Thanh Nho Do

    Full Text Available Intra-gastric balloons (IGB have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient's stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient's stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight.

  19. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    Science.gov (United States)

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  20. High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy.

    Science.gov (United States)

    Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S

    2016-06-01

    Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  1. 3D magnetic-resonance-coupling (MRC) localization of wireless capsule endoscopy

    DEFF Research Database (Denmark)

    Xia, Yongming; Zhang, Lihui; Lu, Kaiyuan

    2016-01-01

    ) technique, which has been widely developed for efficient wireless power transfer, is introduced. It is proposed that the distance dependent signal strength in a MRC system can be beneficially used for 3D localization. The new 3D-MRC localization system consists of three orthogonal emitting coils which......Wireless Capsule Endoscope (WCE) enables developing actively controlled capsule for potential complex surgeries, imaging, and new medicine tests. These tasks of WCE need safe, efficient, and precise 3D localization techniques. In this paper, a new application of the magnetic resonance coupling (MRC...... are powered by a battery in the capsule, and three pairs of orthogonal receiving coils which are placed outside human body. The distances between the WCE and the receiving coils can be estimated with good accuracy by studying the signal strengths in individual receiving coils. The proposed new 3D...

  2. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Callahan, Debbie; Vesey, Roger Alan; Cochrane, Kyle Robert; Nikroo, A.; Bennett, Guy R.; Schroen, Diana Grace; Ruggles, Laurence E.; Porter, John L.; Streit, Jon; Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-01-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  3. In Vivo Characterization of a Wireless Telemetry Module for a Capsule Endoscopy System Utilizing a Conformal Antenna.

    Science.gov (United States)

    Faerber, Julia; Cummins, Gerard; Pavuluri, Sumanth Kumar; Record, Paul; Rodriguez, Adrian R Ayastuy; Lay, Holly S; McPhillips, Rachael; Cox, Benjamin F; Connor, Ciaran; Gregson, Rachael; Clutton, Richard Eddie; Khan, Sadeque Reza; Cochran, Sandy; Desmulliez, Marc P Y

    2018-02-01

    This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10 -3 packet error rate and 10 -5 bit error rate and no temperature increase of the tissue according to IEEE standards.

  4. Robotics in endoscopy.

    Science.gov (United States)

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  5. Jejunal varices diagnosed by capsule endoscopy in patients with post-liver transplant portal hypertension.

    Science.gov (United States)

    Bass, Lee M; Kim, Stanley; Superina, Riccardo; Mohammad, Saeed

    2017-02-01

    Portal hypertension secondary to portal vein obstruction following liver transplant occurs in 5%-10% of children. Jejunal varices are uncommon in this group. We present a case series of children with significant GI blood loss, negative upper endoscopy, and jejunal varices detected by CE. Case series of patients who had CE for chronic GI blood loss following liver transplantation. Three patients who had their initial transplants at a median age of 7 months were identified at our institution presenting at a median age of 8 years (range 7-16 years) with a median Hgb of 2.8 g/dL (range 1.8-6.8 g/dL). Upper endoscopy was negative for significant esophageal varices, gastric varices, and bleeding portal gastropathy in all three children. All three patients had significant jejunal varices noted on CE in mid-jejunum. Jejunal varices were described as large prominent bluish vessels underneath visualized mucosa, one with evidence of recent bleeding. The results led to venoplasty of the portal vein in two patients and a decompressive shunt in one patient with resolution of GI bleed and anemia. CE is useful to diagnose intestinal varices in children with portal hypertension and GI bleeding following liver transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Detecting PHG frames in wireless capsule endoscopy video by integrating rough global dominate-color with fine local texture features

    Science.gov (United States)

    Liu, Xiaoqi; Wang, Chengliang; Bai, Jianying; Liao, Guobin

    2018-02-01

    Portal hypertensive gastropathy (PHG) is common in gastrointestinal (GI) diseases, and a severe stage of PHG (S-PHG) is a source of gastrointestinal active bleeding. Generally, the diagnosis of PHG is made visually during endoscopic examination; compared with traditional endoscopy, (wireless capsule endoscopy) WCE with noninvasive and painless is chosen as a prevalent tool for visual observation of PHG. However, accurate measurement of WCE images with PHG is a difficult task due to faint contrast and confusing variations in background gastric mucosal tissue for physicians. Therefore, this paper proposes a comprehensive methodology to automatically detect S-PHG images in WCE video to help physicians accurately diagnose S-PHG. Firstly, a rough dominatecolor-tone extraction approach is proposed for better describing global color distribution information of gastric mucosa. Secondly, a hybrid two-layer texture acquisition model is designed by integrating co-occurrence matrix into local binary pattern to depict complex and unique gastric mucosal microstructure local variation. Finally, features of mucosal color and microstructure texture are merged into linear support vector machine to accomplish this automatic classification task. Experiments were implemented on an annotated data set including 1,050 SPHG and 1,370 normal images collected from 36 real patients of different nationalities, ages and genders. By comparison with three traditional texture extraction methods, our method, combined with experimental results, performs best in detection of S-PHG images in WCE video: the maximum of accuracy, sensitivity and specificity reach 0.90, 0.92 and 0.92 respectively.

  7. Clinical Efficacy of Various Diagnostic Tests for Small Bowel Tumors and Clinical Features of Tumors Missed by Capsule Endoscopy

    Directory of Open Access Journals (Sweden)

    Jung Wan Han

    2015-01-01

    Full Text Available Background. We aimed to evaluate the efficacy of various diagnostic tools such as computerized tomography (CT, small bowel follow-through (SBFT, and capsule endoscopy (CE in diagnosing small bowel tumors (SBTs. Additionally, we aimed to evaluate the clinical features of SBTs missed by CE. Methods. We retrospectively studied 79 patients with histologically proven SBT. Clinical data were analyzed with particular attention to the efficacy of CT, SBFT, and CE in detecting SBT preoperatively. We also analyzed the clinical features of SBTs missed by CE. Results. The most common symptoms of SBT were bleeding (43% and abdominal pain (13.9%. Diagnostic yields were as follows: CT detected 55.8% of proven SBTs; SBFT, 46.1%; and CE, 83.3%. The sensitivity for detecting SBTs was 40.4% for CT, 43.9% for SBFT, and 79.6% for CE. Two patients with nondiagnostic but suspicious findings on CE and seven patients with negative findings on CE were eventually found to have SBT. These nine patients were eventually diagnosed with gastrointestinal stromal tumor (4, small polyps (3, inflammatory fibroid polyp (1, and adenocarcinoma (1. These tumors were located in the proximal jejunum (5, middle jejunum (1, distal jejunum (1, and proximal ileum (1. Conclusion. CE is more efficacious than CT or SBFT for detecting SBTs. However, significant tumors may go undetected with CE, particularly when located in the proximal jejunum.

  8. Spectrum of small-bowel mucosal abnormalities identified by capsule endoscopy in patients with portal hypertension of varied etiology.

    Science.gov (United States)

    Chandrasekar, T S; Janakan, Gokul Bollu; Chandrasekar, Viveksandeep Thoguluva; Kalamegam, Raja Yogesh; Suriyanarayanan, Sathiamoorthy; Sanjeevaraya, Prasad Menta

    2017-01-01

    Bleeding from small intestinal ectopic varices and persistent anemia caused by portal hypertensive enteropathy (PHE) can be very challenging. Capsule endoscopy (CE) is one of the best noninvasive modalities in identifying such lesions. The aims of this study are to study the prevalence of small-bowel changes related to portal hypertension (PHT) and to correlate them with the observations related to the effects of portal hypertension in the esophagus, stomach, and colon. Thirty-two patients with various etiologies of PHT with either anemia or gastrointestinal bleed were included along with age- and sex-matched controls without PHT. All patients underwent blood tests, gastroscopy, colonoscopy, and CE. The small-bowel findings by CE were categorized as inflammatory-like and vascular lesions. The small-bowel changes were analyzed to find out any association with various demographic, clinical, and endoscopic variables. Thirty-one out of 32 patients with PHT (96.8%) had PHE identified by CE. Of them, 31 (96.8%) had inflammatory-like appearance, 11 (34.4%) had vascular lesions, and 2 (6.2%) had small-bowel varices. Inflammatory-like appearance was noted in eight (25%) and angiodysplastic lesions in two (6.2%) controls. Findings compatible with PHE were detected in 96.8% of the patients and 25% of the controls (X 2 =34.72, p=0.000).The presence of PHE was not associated with any of the above-mentioned variables. Small-bowel mucosal changes were seen in significantly higher number of patients with PHT with anemia.

  9. Optimal use of polyethylene glycol for preparation of small bowel video capsule endoscopy: a network meta-analysis.

    Science.gov (United States)

    Wu, Shan; Gao, Yun-Jie; Ge, Zhi-Zheng

    2017-06-01

    Standardized strategy of bowel preparation before video capsule endoscopy (VCE) remains controversial. This study aimed to assess the ideal dose of PEG, based on small bowel visualization quality (SBVQ), diagnostic yield (DY), and complete rate (CR) of VCE using a network meta-analysis (NMA) of randomized controlled trials (RCTs). This NMA included RCTs comparing any of the following bowel preparation interventions for VCE: fasting overnight ("Fast"), 1 liter PEG ("PEG 1L"), 2-liter PEG ("PEG 2L"), or 4-liter PEG ("PEG 4L"). The authors searched papers in PubMed, Cochrane Library, and Embase as of June 2016. The cumulative ranking (SUCRA) probabilities to rank different doses of PEG and Fast were used. The search engine provided 102 studies. Nine RCTs including 982 patients were incorporated into this analysis. All studies showed low risk of bias of blinding. SUCRA provided an initial ranking among these strategies, in which PEG 2 L showed the best score in SBVQ (PEG 2 L, 89.4%; PEG 1 L, 62.5%; PEG 4 L, 44.0%; Fast, 4.1%) and DY (PEG 2 L, 74.6%; PEG 1 L 28.1%; PEG 4 L 65.9%; Fast 31.4%) of VCE. No significant difference was shown in the analysis of CR. This study recommends PEG 2 L as the ideal dose, which may improve the SBVQ of VCE and, therefore, diagnostic accuracy. Multi-center randomized controlled trials are required to verify these findings.

  10. Dual-Level Security based Cyclic18 Steganographic Method and its Application for Secure Transmission of Keyframes during Wireless Capsule Endoscopy.

    Science.gov (United States)

    Muhammad, Khan; Sajjad, Muhammad; Baik, Sung Wook

    2016-05-01

    In this paper, the problem of secure transmission of sensitive contents over the public network Internet is addressed by proposing a novel data hiding method in encrypted images with dual-level security. The secret information is divided into three blocks using a specific pattern, followed by an encryption mechanism based on the three-level encryption algorithm (TLEA). The input image is scrambled using a secret key, and the encrypted sub-message blocks are then embedded in the scrambled image by cyclic18 least significant bit (LSB) substitution method, utilizing LSBs and intermediate LSB planes. Furthermore, the cover image and its planes are rotated at different angles using a secret key prior to embedding, deceiving the attacker during data extraction. The usage of message blocks division, TLEA, image scrambling, and the cyclic18 LSB method results in an advanced security system, maintaining the visual transparency of resultant images and increasing the security of embedded data. In addition, employing various secret keys for image scrambling, data encryption, and data hiding using the cyclic18 LSB method makes the data recovery comparatively more challenging for attackers. Experimental results not only validate the effectiveness of the proposed framework in terms of visual quality and security compared to other state-of-the-art methods, but also suggest its feasibility for secure transmission of diagnostically important keyframes to healthcare centers and gastroenterologists during wireless capsule endoscopy.

  11. New Evidence on the Impact of Antithrombotics in Patients Submitted to Small Bowel Capsule Endoscopy for the Evaluation of Obscure Gastrointestinal Bleeding

    Directory of Open Access Journals (Sweden)

    Pedro Boal Carvalho

    2014-01-01

    Full Text Available Objectives. Small bowel capsule endoscopy (SBCE plays a decisive role in the obscure gastrointestinal bleeding (OGIB diagnosis. Antithrombotics may increase bleeding risk in patients with preexistent lesions or through direct mucosal aggression. We aimed to correlate antithrombotics usage with lesions with bleeding potential found in SBCE. Methods. Retrospective single-center study including 274 consecutive SBCE performed over 7 years for OGIB. The lesions were classified as P0 (no bleeding potential, P1 (uncertain bleeding potential: erosions, and P2 (high bleeding potential: angioectasias, ulcers, and tumors. We assessed antiplatelet and anticoagulant drug use during the 60 days preceding SBCE. Results. One-third of the patients were under antithrombotic therapy. The diagnostic yield of SBCE for P2 lesions was 30.0%. Angioectasias (20.4% were the most frequently observed lesions. There was a significant correlation between anticoagulant drug use and a higher incidence of P2 lesions in the small bowel (43.2% versus 26.5%; OR = 2.11, P=0.026. We found no significant correlation between antiplatelets and lesions with bleeding potential in SBCE. Conclusions. Small bowel lesions with high bleeding potential were more frequently detected when the patient was on anticoagulant drugs, resulting in a twofold risk. Antiplatelet drugs were not associated with small bowel lesions.

  12. A two-hop wireless power transfer system with an efficiency-enhanced power receiver for motion-free capsule endoscopy inspection.

    Science.gov (United States)

    Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Zhihua

    2012-11-01

    This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.

  13. Feasibility of Capsule Endoscopy for Direct Imaging of Drug Delivery Systems in the Fasted Upper-Gastrointestinal Tract

    DEFF Research Database (Denmark)

    Pedersen, Pernille Barbre; Bar-Shalom, Daniel; Baldursdottir, Stefania

    2014-01-01

    To develop a minimally-invasive method for direct visualization of drug delivery systems in the human stomach and to compare the obtained results with an established in vitro model. The method should provide the capsule rupture, dispersion characteristics, and knowledge regarding the surrounding ...

  14. Morpho-functional evaluation of small bowel using wireless motility capsule and video capsule endoscopy in patients with known or suspected Crohn’s disease: pilot study

    OpenAIRE

    Yung, Diana; Douglas, Sarah; Hobson, Anthony; Giannakou, Andry; Plevris, John; Koulaouzidis, Anastasios

    2016-01-01

    BACKGROUND AND STUDY AIMS:SmartPill(®) (Given Imaging Corp.,Yoqneam,Israel) is an ingestible, non-imaging capsule that records physiological data including contractions and pH throughout the gastrointestinal tract. There are scarce data looking at SmartPill(®) assessment of patients with known/suspected small-bowel Crohn's Disease (CD). This pilot study aims to investigate feasibility and safety of SmartPill(®) to assess gut motility in this group. PATIENTS AND METHODS:Over 1 year, patients w...

  15. Application of colon capsule endoscopy (CCE to evaluate the whole gastrointestinal tract: a comparative study of single-camera and dual-camera analysis

    Directory of Open Access Journals (Sweden)

    Remes-Troche JM

    2013-09-01

    Full Text Available José María Remes-Troche,1 Victoria Alejandra Jiménez-García,2 Josefa María García-Montes,2 Pedro Hergueta-Delgado,2 Federico Roesch-Dietlen,1 Juan Manuel Herrerías-Gutiérrez2 1Digestive Physiology and Motility Lab, Medical Biological Research Institute, Universidad Veracruzana, Veracruz, México; 2Gastroenterology Service, Virgen Macarena University Hospital, Seville, Spain Background and study aims: Colon capsule endoscopy (CCE was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI tract compared to a single-camera analysis. Patients and methods: We included 21 patients (12 males, mean age 56.20 years submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™ was swallowed after reinitiation from its “sleep” mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis; one analyzed images from one side of the device (“camera 1”; and the other reviewed the opposite side (“camera 2”. We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. Results: A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373–0.510. Esophageal (kappa = 0.611 and colorectal (kappa = 0.595 findings had a good level of agreement, while small bowel (kappa = 0.405 showed moderate agreement. Conclusion: The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis. Keywords: capsule endoscopy, colon, gastrointestinal tract, small bowel

  16. The capsule endoscopy "suspected blood indicator" (SBI) for detection of active small bowel bleeding: no active bleeding in case of negative SBI.

    Science.gov (United States)

    Tal, Andrea Oliver; Filmann, Natalie; Makhlin, Konstantin; Hausmann, Johannes; Friedrich-Rust, Mireen; Herrmann, Eva; Zeuzem, Stefan; Albert, Jörg G

    2014-09-01

    Capsule endoscopy (CE) is the gold standard to diagnose small bowel bleeding. The "suspected blood indicator" (SBI) offers an automated detection of active small bowel bleeding but validity of this technique is unknown. The objective was to analyze specificity and sensitivity of the SBI using the second small bowel capsule generation for the detection of active bleeding. This is a retrospective analysis of all patients (199) who attended our clinic for CE from June 2008 through March 2013. The second-generation PillCam SB 2 capsule was used for detection of (1) luminal blood content and (2) potentially responsible small bowel lesions. The findings of an independent investigator were correlated to SBI findings and a number of SBI markings were analyzed by a receiver operating characteristic (ROC). In 157/199 cases, no sign of active bleeding or altered blood was detected. One hundred and thirty-seven of these 157 cases provided at least one SBI marking and a mean of 18.4 positive SBI markings per record were found. In 20 cases, neither SBI nor the human investigator detected abnormalities. Thirteen patients showed investigator-detected minor bleeding with mean SBI findings of 36 positive screenshots per record. When major bleeding was diagnosed by the investigator (n = 29), SBI detected a mean of 46.6 SBI-positive markings. SBI turned positive in 179 patients, whereas the investigator detected active bleeding in 42 cases. All patients with active bleeding were detected by SBI (sensitivity 100%, specificity 13%). ROC analysis revealed 51.0 SBI markings being the optimal cutoff for active versus no bleeding (sensitivity 79.1%, specificity 90.4%, misclassification of 15.3%). The new SBI software is a reliable tool to exclude active bleeding and/or major lesions but analysis of the CE video by a trained investigator is still important for the detection of lesions responsible for past bleeding.

  17. Swallowing Tablets and Capsules Increases the Risk of Penetration and Aspiration in Patients with Stroke-Induced Dysphagia.

    Science.gov (United States)

    Schiele, Julia T; Penner, Heike; Schneider, Hendrik; Quinzler, Renate; Reich, Gabriele; Wezler, Nikolai; Micol, William; Oster, Peter; Haefeli, Walter E

    2015-10-01

    We evaluated the prevalence of difficulties swallowing solid dosage forms in patients with stroke-induced dysphagia and whether swallowing tablets/capsules increases their risk of penetration and aspiration. Concurrently, we explored whether routinely performed assessment tests help identify patients at risk. Using video endoscopy, we evaluated how 52 patients swallowed four different placebos (round, oval, and oblong tablets and a capsule) with texture-modified water (TMW, pudding consistency) and milk and rated their swallowing performance according to the Penetration Aspiration Scale (PAS). Additionally, Daniels Test, Bogenhausener Dysphagiescore, Scandinavian Stroke Scale, Barthel Index, and Tinetti's Mobility Test were conducted. A substantial proportion of the patients experienced severe difficulties swallowing solid oral dosage forms (TMW: 40.4 %, milk: 43.5 %). Compared to the administration of TMW/milk alone, the placebos increased the PAS values in the majority of the patients (TMW: median PAS from 1.5 to 2.0; milk: median PAS from 1.5 to 2.5, each p value <0.0001) and residue values were significantly higher (p < 0.05). Whereas video-endoscopic examination reliably identified patients with difficulties swallowing medication, neither patients' self-evaluation nor one of the routinely performed bedside tests did. Therefore, before video-endoscopic evaluation, many drugs were modified unnecessarily and 20.8 % of these were crushed inadequately, although switching to another dosage form or drug would have been possible. Hence, safety and effectiveness of swallowing tablets and capsules should be evaluated routinely in video-endoscopic examinations, tablets/capsules should rather be provided with TMW than with milk, and the appropriateness of "non per os except medication" orders for dysphagic stroke patients should be questioned.

  18. Feasibility and diagnostic utility of video capsule endoscopy for the detection of small bowel polyps in patients with hereditary polyposis syndromes.

    Science.gov (United States)

    Schulmann, Karsten; Hollerbach, Stephan; Kraus, Katja; Willert, Jörg; Vogel, Tilman; Möslein, Gabriela; Pox, Christian; Reiser, Markus; Reinacher-Schick, Anke; Schmiegel, Wolff

    2005-01-01

    At present, surveillance of premalignant small bowel polyps in hereditary polyposis syndromes has a number of limitations. Capsule endoscopy (CE) is a promising new method to endoscopically assess the entire length of the small bowel. We prospectively examined 40 patients with hereditary polyposis syndromes (29 familial adenomatous polyposis (FAP), 11 Peutz-Jeghers syndrome (PJS)). Results were compared with push-enteroscopy (PE) results in FAP and with esophagogastroduodenoscopy, PE, (MR)-enteroclysis, and surgical specimen in PJS patients. A total of 76% of the patients with FAP with duodenal adenomas (n = 21) had additional adenomas in the proximal jejunum that could be detected by CE and PE. Moreover, 24% of these FAP patients had further polyps in the distal jejunum or ileum that could only be detected by CE. In contrast, in FAP patients without duodenal polyps (n = 8), jejunal or ileal polyps occurred rarely (12%). CE detected polyps in 10 of 11 patients with PJS, a rate superior to all other reference procedures employed. Importantly, the findings of CE had immediate impact on further clinical management in all PJS patients. Our results suggest that CE may be of clinical value in selected patients with FAP, whereas in PJS, CE could be used as first line surveillance procedure.

  19. Diagnostic yield and safety of capsule endoscopy Rendimiento diagnóstico y seguridad de la cápsula endoscópica

    Directory of Open Access Journals (Sweden)

    J. L. Matas

    2006-09-01

    Full Text Available Introduction: the capsule endoscopy (CE, from his approval, has become a first line diagnostic procedure for the study of the small bowel disease. The aim of this study is to report our experience since the implantation of this technique in our hospital. Material and methods: retrospective review of the CE undertaken in Department of Endoscopy. There was gathered in every case the age, sex, motive of consultation, previous diagnostic procedures, capsule endoscopy findings and complication of the technique. One took to end a descriptive and analytical analysis. Results: there was achieved a total of 416 explorations in 388 patients. The obscure gastrointestinal bleeding was the most frequent indication (83.30% followed by suspected Crohn's disease (7.5%. Angiodisplasia was the endoscopic lesion more frequently detected (42.2%, especially, in patients with digestive bleeding of obscure origin (OR 3.13 p Introducción: la cápsula endoscópica desde su aprobación se ha convertido en un procedimiento diagnóstico de primera línea para el estudio del intestino delgado. El objetivo del estudio es exponer la experiencia desde la implantación de esta técnica en nuestro hospital. Material y métodos: se hizo una revisión retrospectiva de los estudios realizados en el Servicio de Endoscopia. Se recogió en cada caso la edad, sexo, motivo de consulta, procedimientos diagnósticos previos, diagnósticos endoscópicos e incidencias inherentes a la técnica y se llevó a cabo un análisis descriptivo y analítico. Resultados: se realizaron un total de 416 exploraciones en 388 pacientes. La hemorragia digestiva de origen oscuro fue la indicación más frecuente (83,30% seguida de la sospecha de enfermedad de Crohn (7,5%. La angiodisplasia fue la lesión endoscópica más detectada (42,2% cuando se analizó la hemorragia digestiva oscura (OR 3.13 p < 0,001 seguida de la flebectasia (10,6% y las úlceras sugerentes de enfermedad de Crohn (9,9%. La

  20. Virtual chromoendoscopy can be a useful software tool in capsule endoscopy La Cromoendoscopia virtual puede ser una herramienta de software útil en la cápsula endoscópica

    Directory of Open Access Journals (Sweden)

    Gabriela Duque

    2012-05-01

    Full Text Available Background: capsule endoscopy (CE has revolutionized the study of small bowel. One major drawback of this technique is that we cannot interfere with image acquisition process. Therefore, the development of new software tools that could modify the images and increase both detection and diagnosis of small-bowel lesions would be very useful. The Flexible Spectral Imaging Color Enhancement (FICE that allows for virtual chromoendoscopy is one of these software tools. Aims: to evaluate the reproducibility and diagnostic accuracy of the FICE system in CE. Methods: this prospective study involved 20 patients. First, four physicians interpreted 150 static FICE images and the overall agree-ment between them was determined using the Fleiss Kappa Test. Second, two experienced gastroenterologists, blinded to each other results, analyzed the complete 20 video streams. One interpreted conventional capsule videos and the other, the CE-FICE videos at setting 2. All findings were reported, regardless of their clinical value. Non-concordant findings between both interpretations were analyzed by a consensus panel of four gastroenterologists who reached a final result (positive or negative finding. Results: in the first arm of the study the overall concordance between the four gastroenterologists was substantial (0.650. In the second arm, the conventional mode identified 75 findings and the CE-FICE mode 95. The CE-FICE mode did not miss any lesions identified by the conventional mode and allowed the identification of a higher number of angiodysplasias (35 vs 32, and erosions (41 vs. 24. Conclusions: there is reproducibility for the interpretation of CE-FICE images between different observers experienced in conventional CE. The use of virtual chromoendoscopy in CE seems to increase its diagnostic accuracy by highlighting small bowel erosions and angiodysplasias that weren't identified by the conventional mode.

  1. Upper gastrointestinal findings detected by capsule endoscopy in obscure gastrointestinal bleeding Hallazgos digestivos altos de la cápsula endoscópica en la hemorragia digestiva de origen oscuro

    Directory of Open Access Journals (Sweden)

    B. Velayos

    2009-01-01

    Full Text Available Objective: we analyzed our experience with the use of capsule endoscopy in areas that can be explored with gastroscopy to justify obscure bleeding, as well as the outcome after a new recommended gastroscopy in order to determine if a second gastroscopy before the capsule study can provide any benefit in the management of this disease. Methods: we retrospectively studied 82 patients who were explored with capsule endoscopy for obscure gastrointestinal bleeding who had undergone previously only one gastroscopy. Findings in the zones which were accessible by gastroscopy were normal, mild/known and severe/unknown. In the latter cases we recommended a second gastroscopy, and their treatment and outcome were subjected to further study. Results: capsule endoscopy did not find any unknown esophageal findings. In 63% of cases, no gastric or duodenal lesions were shown; in 20%, lesions were mild or had been previously diagnosed, and in 17%, a new gastroscopy was recommended due to the discovery of an unknown condition which could be the cause of the obscure bleeding. This new information brought about a change in treatment for 78% of patients in this group, all of whom improved from their illness. Capsule endoscopy found significant intercurrent alterations in the small intestine in only 14% of cases. Conclusions: the performance of a second gastroscopy, previous to capsule endoscopy, in the study of obscure gastrointestinal bleeding can offer benefits in diagnostic terms and may introduce therapeutic changes. A detailed analysis of the upper tract frames in intestinal capsule endoscopy studies is mandatory since it may provide relevant information with clinical impact on the management of these patients.Objetivo: hemos analizado los hallazgos que la cápsula endoscópica aportó de las zonas accesibles a una gastroscopia que podrían justificar un sangrado digestivo oscuro, así como la evolución de estos enfermos tras la nueva gastroscopia recomendada

  2. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Science.gov (United States)

    Rendueles, Olaya; Garcia-Garcerà, Marc; Néron, Bertrand; Touchon, Marie; Rocha, Eduardo P C

    2017-07-01

    Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by-product of environmental

  3. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Directory of Open Access Journals (Sweden)

    Olaya Rendueles

    2017-07-01

    Full Text Available Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by

  4. Usefulness of capsule endoscopy in patients with suspected small bowel disease Utilidad de la cápsula endoscópica en pacientes con sospecha de patología de intestino delgado

    Directory of Open Access Journals (Sweden)

    A. Caunedo

    2004-01-01

    Full Text Available Aim: to study the usefulness and safety of capsule endoscopy as a diagnostic tool in various small bowel disorders. Design: a retrospective analysis of a series of cases. Material and methods: between August 2001 and August 2002, 92 capsule endoscopy procedures were performed in 88 patients (53M/39F, age: 43.87 ± 16.78. Indications included: chronic diarrhea (n = 33; unknown abdominal pain (n = 29; occult gastrointestinal bleeding or iron-deficiency anemia (n = 13; abdominal discomfort in NSAID takers (n = 7; staging of gastrointestinal tumors (n = 4, and asymptomatic controls (n = 2. Previously performed gastroscopy, colonoscopy, and small-bowel follow-through were not conclusive in all patients. Results: most frequently relevant findings included: jejuno-ileal apthas and ulcerations (29 patients, vascular malformations (13 patients, and intestinal neoplasm (6 patients. The groups with a higher rate of findings related to this indication were occult gastrointestinal bleeding (76.92% and chronic diarrhea (67.85%, with the lowest rate in the abdominal pain group (34.48%. Therapeutic strategy was directly changed in 36 of 88 patients (40.90% because of capsule-endoscopic findings. The only observed complication was the failed excretion of one of the capsules because of an unknown ulcerated intestinal stricture. Conclusions: capsule endoscopy is a safe procedure which can study the entire small bowel, meaning a valuable tool for the management of patients with suggestive signs and symptoms of intestinal disorders.Objetivo: estudiar la utilidad y seguridad de la cápsula endoscópica como prueba diagnóstica en distintas patologías de intestino delgado. Diseño: análisis retrospectivo de una serie de casos. Material y métodos: entre agosto de 2001 y agosto de 2002 se realizaron 92 cápsulo-endoscopias a 88 pacientes (53H/39M, edad: 43,87± 16,78. Las indicaciones fueron: diarrea crónica (n = 33; dolor abdominal no filiado (n = 29; hemorragia

  5. Increasing robustness of indirect drive capsule designs against short wavelength hydrodynamic instabilities

    International Nuclear Information System (INIS)

    Haan, S.W.; Herrmann, M.C.; Dittrich, T.R.; Fetterman, A.J.; Marinak, M.M.; Munro, D.H.; Pollaine, S.M.; Salmonson, J.D.; Strobel, G.L.; Suter, L.J.

    2005-01-01

    Targets meant to achieve ignition on the National Ignition Facility (NIF) [J. A. Paisner, J. D. Boyes, S. A. Kumpan, W. H. Lowdermilk, and M. S. Sorem, Laser Focus World 30, 75 (1994)] have been redesigned and their performance simulated. Simulations indicate dramatically reduced growth of short wavelength hydrodynamic instabilities, resulting from two changes in the designs. First, better optimization results from systematic mapping of the ignition target performance over the parameter space of ablator and fuel thickness combinations, using techniques developed by one of us (Herrmann). After the space is mapped with one-dimensional simulations, exploration of it with two-dimensional simulations quantifies the dependence of instability growth on target dimensions. Low modes and high modes grow differently for different designs, allowing a trade-off of the two regimes of growth. Significant improvement in high-mode stability can be achieved, relative to previous designs, with only insignificant increase in low-mode growth. This procedure produces capsule designs that, in simulations, tolerate several times the surface roughness that could be tolerated by capsules optimized by older more heuristic techniques. Another significant reduction in instability growth, by another factor of several, is achieved with ablators with radially varying dopant. In this type of capsule the mid-Z dopant, which is needed in the ablator to minimize x-ray preheat at the ablator-ice interface, is optimally positioned within the ablator. A fabrication scenario for graded dopants already exists, using sputter coating to fabricate the ablator shell. We describe the systematics of these advances in capsule design, discuss the basis behind their improved performance, and summarize how this is affecting our plans for NIF ignition

  6. Technical endoscopy

    International Nuclear Information System (INIS)

    Cavalar, K.O.

    1988-01-01

    A survey is provided on different versions of endoscopes, taking into account the new developments of video endoscopy. With a variety of practical examples it is shown that technical tests using endoscopy are a demanding task for nondestructive testing, whose requirements can only be met on a customized basis. (orig./HP) [de

  7. Increased serological cancer-associated biomarker levels at large bowel endoscopy and risk of subsequent primary cancer (†)

    DEFF Research Database (Denmark)

    Hvolris, Martin H; Piper, Thomas B; Hammer, Emilie

    2016-01-01

    Background: Frequently, subjects offered colonoscopy due to symptoms of colorectal neoplasia are diagnosed with diverticula. The symptoms may, however, also be related to extra-colonic neoplasia. The present retrospective study evaluated a possible association between increased levels of predefined...... biomarkers in subjects diagnosed with diverticula and risk of developing a primary malignant disease. Methods: During 2004/2005, about 4509 subjects were included in a multicenter study with collection of blood samples before bowel endoscopy. The aim was to evaluate a relation between the protein biomarkers...... was calculated. The relation with the four biomarkers was divided into three groups: 0 = none increased; 1 = one increased and 2 = two or more increased. Results: In the observation period, 148 subjects developed a primary malignant disease. Univariable analyzes of the biomarker levels showed that CEA, TIMP-1...

  8. Increase in female faculty in American Society for Gastrointestinal Endoscopy-sponsored programming over time.

    Science.gov (United States)

    Enestvedt, Brintha K; DeVivo, Rebecca S; Schmitt, Colleen M; Calderwood, Audrey H

    2018-04-01

    Female representation in medicine is increasing across all levels of medical training, yet women hold fewer senior leadership positions than men. National recognition, including participation as faculty in society-sponsored programs, is one component of academic advancement. The aim of this study was to characterize female representation among faculty in courses sponsored by the American Society for Gastrointestinal Endoscopy (ASGE). We performed a retrospective review of demographic data, including faculty gender and role, year, and program type, from the ASGE database of its sponsored programs between 2009 and 2014. Female faculty rates were compared with the rate of female membership in the ASGE and by faculty role and course type over time. Between 2009 and 2014 there were a total of 2020 ASGE course faculty positions of which women comprised 19%. There was a significant increase in the proportion of women that served as course faculty over time (P < .0005). Female faculty participation exceeded the ASGE female domestic membership rate in all years. Women were more likely to serve as course directors than lecturers (25% vs 18%, P = .004) and to participate in smaller courses (P = .0003). We found an increase in female participation in ASGE programming over time, suggesting that specialty societies are making efforts to improve female representation at the national level. Future work should evaluate whether or not these opportunities translate into leadership roles for women within their own institutions or lead to promotions for women over time. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. Combined high-field intraoperative magnetic resonance imaging and endoscopy increase extent of resection and progression-free survival for pituitary adenomas

    Science.gov (United States)

    Sylvester, Peter T.; Evans, John A.; Zipfel, Gregory J.; Chole, Richard A.; Uppaluri, Ravindra; Haughey, Bruce H.; Getz, Anne E.; Silverstein, Julie; Rich, Keith M.; Kim, Albert H.; Dacey, Ralph G.

    2014-01-01

    Purpose The clinical benefit of combined intraoperative magnetic resonance imaging (iMRI) and endoscopy for transsphenoidal pituitary adenoma resection has not been completely characterized. This study assessed the impact of microscopy, endoscopy, and/or iMRI on progression-free survival, extent of resection status (gross-, near-, and subtotal resection), and operative complications. Methods Retrospective analyses were performed on 446 transsphenoidal pituitary adenoma surgeries at a single institution between 1998 and 2012. Multivariate analyses were used to control for baseline characteristics, differences during extent of resection status, and progression-free survival analysis. Results Additional surgery was performed after iMRI in 56/156 cases (35.9 %), which led to increased extent of resection status in 15/156 cases (9.6 %). Multivariate ordinal logistic regression revealed no increase in extent of resection status following iMRI or endoscopy alone; however, combining these modalities increased extent of resection status (odds ratio 2.05, 95 % CI 1.21–3.46) compared to conventional transsphenoidal microsurgery. Multivariate Cox regression revealed that reduced extent of resection status shortened progression-free survival for near- versus gross-total resection [hazard ratio (HR) 2.87, 95 % CI 1.24–6.65] and sub- versus near-total resection (HR 2.10; 95 % CI 1.00–4.40). Complication comparisons between microscopy, endoscopy, and iMRI revealed increased perioperative deaths for endoscopy versus microscopy (4/209 and 0/237, respectively), but this difference was non-significant considering multiple post hoc comparisons (Fisher exact, p = 0.24). Conclusions Combined use of endoscopy and iMRI increased pituitary adenoma extent of resection status compared to conventional transsphenoidal microsurgery, and increased extent of resection status was associated with longer progression-free survival. Treatment modality combination did not significantly impact

  10. Hindfoot endoscopy

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies; most of these can be diagnosed and treated by means of endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a peroneus brevis length rupture, peroneal tendon athesiolysis, flexor hallucis longus release, os

  11. Recombination in Streptococcus pneumoniae Lineages Increase with Carriage Duration and Size of the Polysaccharide Capsule

    Science.gov (United States)

    Andam, Cheryl P.; Harris, Simon R.; Cornick, Jennifer E.; Yang, Marie; Bricio-Moreno, Laura; Kamng’ona, Arox W.; French, Neil; Heyderman, Robert S.; Kadioglu, Aras; Everett, Dean B.; Bentley, Stephen D.

    2016-01-01

    ABSTRACT Streptococcus pneumoniae causes a high burden of invasive pneumococcal disease (IPD) globally, especially in children from resource-poor settings. Like many bacteria, the pneumococcus can import DNA from other strains or even species by transformation and homologous recombination, which has allowed the pneumococcus to evade clinical interventions such as antibiotics and pneumococcal conjugate vaccines (PCVs). Pneumococci are enclosed in a complex polysaccharide capsule that determines the serotype; the capsule varies in size and is associated with properties including carriage prevalence and virulence. We determined and quantified the association between capsule and recombination events using genomic data from a diverse collection of serotypes sampled in Malawi. We determined both the amount of variation introduced by recombination relative to mutation (the relative rate) and how many individual recombination events occur per isolate (the frequency). Using univariate analyses, we found an association between both recombination measures and multiple factors associated with the capsule, including duration and prevalence of carriage. Because many capsular factors are correlated, we used multivariate analysis to correct for collinearity. Capsule size and carriage duration remained positively associated with recombination, although with a reduced P value, and this effect may be mediated through some unassayed additional property associated with larger capsules. This work describes an important impact of serotype on recombination that has been previously overlooked. While the details of how this effect is achieved remain to be determined, it may have important consequences for the serotype-specific response to vaccines and other interventions. PMID:27677790

  12. Recombination in Streptococcus pneumoniae Lineages Increase with Carriage Duration and Size of the Polysaccharide Capsule

    Directory of Open Access Journals (Sweden)

    Chrispin Chaguza

    2016-09-01

    Full Text Available Streptococcus pneumoniae causes a high burden of invasive pneumococcal disease (IPD globally, especially in children from resource-poor settings. Like many bacteria, the pneumococcus can import DNA from other strains or even species by transformation and homologous recombination, which has allowed the pneumococcus to evade clinical interventions such as antibiotics and pneumococcal conjugate vaccines (PCVs. Pneumococci are enclosed in a complex polysaccharide capsule that determines the serotype; the capsule varies in size and is associated with properties including carriage prevalence and virulence. We determined and quantified the association between capsule and recombination events using genomic data from a diverse collection of serotypes sampled in Malawi. We determined both the amount of variation introduced by recombination relative to mutation (the relative rate and how many individual recombination events occur per isolate (the frequency. Using univariate analyses, we found an association between both recombination measures and multiple factors associated with the capsule, including duration and prevalence of carriage. Because many capsular factors are correlated, we used multivariate analysis to correct for collinearity. Capsule size and carriage duration remained positively associated with recombination, although with a reduced P value, and this effect may be mediated through some unassayed additional property associated with larger capsules. This work describes an important impact of serotype on recombination that has been previously overlooked. While the details of how this effect is achieved remain to be determined, it may have important consequences for the serotype-specific response to vaccines and other interventions.

  13. Increased Risk for Adhesive Capsulitis of the Shoulder following Cervical Disc Surgery.

    Science.gov (United States)

    Kang, Jiunn-Horng; Lin, Herng-Ching; Tsai, Ming-Chieh; Chung, Shiu-Dong

    2016-05-27

    Shoulder problems are common in patients with a cervical herniated intervertebral disc (HIVD). This study aimed to explore the incidence and risk of shoulder capsulitis/tendonitis following cervical HIVD surgery. We used data from the Taiwan "Longitudinal Health Insurance Database". We identified all patients who were hospitalized with a diagnosis of displacement of a cervical HIVD and who underwent cervical surgery (n = 1625). We selected 8125 patients who received cervical HIVD conservative therapy only as the comparison group matched with study patients. We individually tracked these sampled patients for 6 months to identify all patients who received a diagnosis of shoulder tendonitis/capsulitis. We found that incidence rates of shoulder tendonitis/capsulitis during the 6-month follow-up period were 3.69 (95% CI: 2.49~5.27) per 100 person-years for the study group and 2.33 (95% CI: 1.89~2.86) per 100 person-years for the comparison group. Cox proportional hazard regressions showed that the adjusted hazard ratio for shoulder tendonitis/capsulitis among patients who underwent cervical disc surgery was 1.66 (95% CI = 1.09~2.53) when compared to comparison group. We concluded that patients who underwent surgery for a cervical HIVD had a significantly higher risk of developing shoulder capsulitis/tendonitis in 6 months follow-up compared to patients who received cervical HIVD conservative therapy only.

  14. Decreasing size of radiosensitive capsules from micro to nano, and its increased antitumor effect and decreasing adverse effect

    International Nuclear Information System (INIS)

    Harada, S.; Ehara, S.; Ishii, K.; Yamazaki, H.; Matsuyama, S.; Sato, Takahiro; Kamiya, Tomihiro; Sera, K.; Saito, Y.

    2012-01-01

    We have been developing microcapsules that release anticancer drug with response to radiation. We attempted to decrease the diameter of capsules. Then, two categories were tested in VIVO in C3He mice: (1) the antitumor effect in combination with radiation and subcutaneously injected nanocapsules, (2) the kidnetics of nanocapsules when they were injected intravenously. Microcapsules were produced by spraying a mixture of 3.0 % hyaluronic acid, 2.0 % alginate, 3.0 % H 2 O 2 , and 0.3 mmol carboplatin (Pt containing anticancer drug) onto a mixture of vibrated 0.3 mol FeCl 2 and 0.15 mol CaCl 2 . The antitumor effect was measured by measuring tumor diameter every day. The kinetics of microcapsules were expressed as the numbers of capsules in 5 views (25 x 25 μm) of micro PIXE camera and Pt concentration of quantiative PIXE. The generated microcapsules 752 ± 64 nm, which were significantly downsized relative to previous capsules. The accumulations of capsules in lungs, liver, and kidneys were decreased by downsizing, whereas those of tumors were increased. By adjusting Pt concentration in tumor, there were no significant differences in antitumor effect between not downsized and downsized microcapsules with combination with radiation. Decreased trapping of downsized microcapsules to lungs, liver, and kidneys, also increased trapping in tumors will lead to new targeted chemoradiotherapy via intravenous injection of microcapsules. (author)

  15. Capsule endoscopy: new technology | Schneider | South African ...

    African Journals Online (AJOL)

    South African Gastroenterology Review. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 2, No 1 (2004) >. Log in or Register to get access to full text downloads.

  16. in upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Sinan Uzman

    2016-07-01

    Full Text Available Introduction : There is increasing interest in sedation for upper gastrointestinal endoscopy (UGE. Prospective randomized studies comparing sedation properties and complications of propofol and midazolam/meperidine in upper gastrointestinal endoscopy (UGE are few. Aim: To compare propofol and midazolam/meperidine sedation for UGE in terms of cardiopulmonary side effects, patient and endoscopist satisfaction and procedure-related times. Material and methods: This was a prospective, randomized, double-blind study of propofol versus midazolam and meperidine in 100 patients scheduled for diagnostic upper gastrointestinal endoscopy. The patients were divided into propofol and midazolam/meperidine groups. Randomization was generated by a computer. Cardiopulmonary side effects (hypotension, bradycardia, hypoxemia, procedure-related times (endoscopy time, awake time, time to hospital discharge, and patient and endoscopist satisfaction were compared between groups. Results: There was no significant difference between the groups with respect to the cost, endoscopy time, or demographic and clinical characteristics of the patients. Awake time and time to hospital discharge were significantly shorter in the propofol group (6.58 ±4.72 vs. 9.32 ±4.26 min, p = 0.030 and 27.60 ±7.88 vs. 32.00 ±10.54 min, p = 0.019. Hypotension incidence was significantly higher in the propofol group (12% vs. 0%, p = 0.027. The patient and endoscopist satisfaction was better with propofol. Conclusions : Propofol may be preferred to midazolam/meperidine sedation, with a shorter awake and hospital discharge time and better patient and endoscopist satisfaction. However, hypotension risk should be considered with propofol, and careful evaluation is needed, particularly in cardiopulmonary disorders.

  17. The use of selective serotonin receptor inhibitors (SSRIs) is not associated with increased risk of endoscopy-refractory bleeding, rebleeding or mortality in peptic ulcer bleeding.

    Science.gov (United States)

    Laursen, S B; Leontiadis, G I; Stanley, A J; Hallas, J; Schaffalitzky de Muckadell, O B

    2017-08-01

    Observational studies have consistently shown an increased risk of upper gastrointestinal bleeding in users of selective serotonin receptor inhibitors (SSRIs), probably explained by their inhibition of platelet aggregation. Therefore, treatment with SSRIs is often temporarily withheld in patients with peptic ulcer bleeding. However, abrupt discontinuation of SSRIs is associated with development of withdrawal symptoms in one-third of patients. Further data are needed to clarify whether treatment with SSRIs is associated with poor outcomes, which would support temporary discontinuation of treatment. To identify if treatment with SSRIs is associated with increased risk of: (1) endoscopy-refractory bleeding, (2) rebleeding or (3) 30-day mortality due to peptic ulcer bleeding. A nationwide cohort study. Analyses were performed on prospectively collected data on consecutive patients admitted to hospital with peptic ulcer bleeding in Denmark in the period 2006-2014. Logistic regression analyses were used to investigate the association between treatment with SSRIs and outcome following adjustment for pre-defined confounders. Sensitivity and subgroup analyses were performed to evaluate the validity of the findings. A total of 14 343 patients were included. Following adjustment, treatment with SSRIs was not associated with increased risk of endoscopy-refractory bleeding (odds ratio [OR] [95% Confidence Interval (CI)]: 1.03 [0.79-1.33]), rebleeding (OR [95% CI]: 0.96 [0.83-1.11]) or 30-day mortality (OR [95% CI]: 1.01 [0.85-1.19]. These findings were supported by sensitivity and subgroup analyses. According to our data, treatment with SSRIs does not influence the risk of endoscopy-refractory bleeding, rebleeding or 30-day mortality in peptic ulcer bleeding. © 2017 John Wiley & Sons Ltd.

  18. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  19. Proteomic analysis of the increased stress tolerance of saccharomyces cerevisiae encapsulated in liquid core alginate-chitosan capsules.

    Directory of Open Access Journals (Sweden)

    Johan O Westman

    Full Text Available Saccharomyces cerevisiae CBS8066 encapsulated in semi-permeable alginate or alginate-chitosan liquid core capsules have been shown to have an enhanced tolerance towards complex dilute-acid lignocellulose hydrolysates and the lignocellulose-derived inhibitor furfural, as well as towards high temperatures. The underlying molecular reasons for these effects have however not been elucidated. In this study we have investigated the response of the encapsulation on the proteome level in the yeast cells, in comparison with cells grown freely in suspension under otherwise similar conditions. The proteomic analysis was performed on whole cell protein extracts using nLC-MS/MS with TMT® labelling and 2-D DIGE. 842 and 52 proteins were identified using each method, respectively. The abundances of 213 proteins were significantly different between encapsulated and suspended cells, with good correlation between the fold change ratios obtained by the two methods for proteins identified in both. Encapsulation of the yeast caused an up-regulation of glucose-repressed proteins and of both general and starvation-specific stress responses, such as the trehalose biosynthesis pathway, and down-regulation of proteins linked to growth and protein synthesis. The encapsulation leads to a lack of nutrients for cells close to the core of the capsule due to mass transfer limitations. The triggering of the stress response may be beneficial for the cells in certain conditions, for example leading to the increased tolerance towards high temperatures and certain inhibitors.

  20. Nanotechnology in gastrointestinal endoscopy: A primer

    Directory of Open Access Journals (Sweden)

    Ashish Kumar Jha

    2012-01-01

    Full Text Available Nanotechnology is the understanding, control of matter and development of engineered devices in nanometer range (1-100 nm. Nanoparticles have different physicochemical properties (small size, large surface area to volume ratio, and high reactivity in comparison to bulk materials of the same composition. The nanotechnology has proved its usefulness in early diagnosis, proteonomics, imaging diagnostics and multifunctional therapeutics. Recent studies have shown its role in early diagnosis and targeted therapy of various gastrointestinal disorders such as hepatitis B virus and hepatitis C virus related liver disease, inflammatory bowel disease, gastric ulcer, and malignancy. Application of this technology appears promising in diagnostic and therapeutic endoscopy such as the endoscopic hemostasis of peptic ulcer bleeding, prevention of clogging of plastic stent and advance capsule endoscopy. This article will highlight the basic concepts of nanotechnology and its potential application in gastrointestinal endoscopy.

  1. The use of selective serotonin receptor inhibitors (SSRIs) is not associated with increased risk of endoscopy-refractory bleeding, rebleeding or mortality in peptic ulcer bleeding

    DEFF Research Database (Denmark)

    Laursen, S B; Leontiadis, Grigorios I; Stanley, Adrian J

    2017-01-01

    in patients with peptic ulcer bleeding. However, abrupt discontinuation of SSRIs is associated with development of withdrawal symptoms in one-third of patients. Further data are needed to clarify whether treatment with SSRIs is associated with poor outcomes, which would support temporary discontinuation...... of treatment. AIM: To identify if treatment with SSRIs is associated with increased risk of: (1) endoscopy-refractory bleeding, (2) rebleeding or (3) 30-day mortality due to peptic ulcer bleeding. METHODS: A nationwide cohort study. Analyses were performed on prospectively collected data on consecutive...... patients admitted to hospital with peptic ulcer bleeding in Denmark in the period 2006-2014. Logistic regression analyses were used to investigate the association between treatment with SSRIs and outcome following adjustment for pre-defined confounders. Sensitivity and subgroup analyses were performed...

  2. Potential impact of enhanced practice efficiency on endoscopy waiting times.

    LENUS (Irish Health Repository)

    Harewood, G C

    2009-06-01

    With the growing demand on endoscopy services, optimising practice efficiency has assumed increasing importance. Prior research has identified practice changes, which increase the efficiency in endoscopy. In this study, the potential impact of these practice changes on the current and projected future endoscopy waiting times at our institution was assessed.

  3. Efficacy of pediatric colonoscopy used as push enteroscopy in the management of capsule endoscopy findings Eficacia del colonoscopio pediátrico como enteroscopio de pulsión en el manejo de los hallazgos de la cápsula endoscópica

    Directory of Open Access Journals (Sweden)

    F. Pérez Roldán

    2009-07-01

    Full Text Available Background: recent advances in endoscopy have enabled us to explore the small intestine more efficiently, both with capsule endoscopy and double-balloon enteroscopy. However, these methods are not available in all hospitals. Therefore, when capsule endoscopy reveals proximal jejunal lesions, a possible alternative for treatment could involve push enteroscopy combined with colonoscopy. Lesions can thus be marked for subsequent monitoring. Objectives: to describe the efficacy of pediatric colonoscopy for diagnosis, the marking of the area explored, and therapeutic options. Material and methods: between October 2007 and September 2008 a total of 21 enteroscopies were performed using a pediatric colonoscope. Nine of these were used to take jejunal biopsy samples due to suspected disease of the mucosa. In 10 of the remaining 12, capsule endoscopy revealed lesions (vascular malformations or jejunal bleeding, and in 2 intestinal transit time was analyzed due to suspected jejunal stenosis. We used a PENTAX EC-3470-LK pediatric colonoscope, whose 11.6-mm sectional diameter and 3.8-mm working channel make it possible to administer all the usual endoscopic treatments. Results: therapeutic endoscopy was performed on 7 men and 5 women (mean age 63.3 years. Jejunal lesions were observed in 10 cases (5 cases of angiodysplasia, 2 cases of jejunal stenosis, 1 case of nonmalignant thickened jejunal folds, 1 eroded submucosal tumor, and 1 case of duodenal and jejunal varices. The most distal area was marked with India ink (2, hemoclips (4, or both to help locate the lesions using simple abdominal radiography or capsule endoscopy. Conclusions: jejunal enteroscopy enabled a firm diagnosis to be made in most of the patients studied. We were able to treat 58% of patients and mark the areas explored for subsequent follow-up. With hemoclips we were able to locate the most distal point explored using simple abdominal radiography.Introducción: los recientes avances en

  4. Photometric stereo endoscopy.

    Science.gov (United States)

    Parot, Vicente; Lim, Daryl; González, Germán; Traverso, Giovanni; Nishioka, Norman S; Vakoc, Benjamin J; Durr, Nicholas J

    2013-07-01

    While color video endoscopy has enabled wide-field examination of the gastrointestinal tract, it often misses or incorrectly classifies lesions. Many of these missed lesions exhibit characteristic three-dimensional surface topographies. An endoscopic system that adds topographical measurements to conventional color imagery could therefore increase lesion detection and improve classification accuracy. We introduce photometric stereo endoscopy (PSE), a technique which allows high spatial frequency components of surface topography to be acquired simultaneously with conventional two-dimensional color imagery. We implement this technique in an endoscopic form factor and demonstrate that it can acquire the topography of small features with complex geometries and heterogeneous optical properties. PSE imaging of ex vivo human gastrointestinal tissue shows that surface topography measurements enable differentiation of abnormal shapes from surrounding normal tissue. Together, these results confirm that the topographical measurements can be obtained with relatively simple hardware in an endoscopic form factor, and suggest the potential of PSE to improve lesion detection and classification in gastrointestinal imaging.

  5. Endoscopy in pregnancy.

    LENUS (Irish Health Repository)

    O'mahony, Seamus

    2012-02-03

    Endoscopy is rarely required during pregnancy. The potential risks of endoscopy during pregnancy include foetal hypoxia due to sedative drugs and exposure to radiation. There is no evidence that endoscopy precipitates premature labour, and studies in this area have concluded that endoscopy during pregnancy is generally safe. There should be a strong indication for the procedure, which should be deferred whenever possible to the second trimester. Procedures should be performed without any sedation, or with the lowest dose of sedative medication. Radiation exposure should be kept to a minimum. Support should be obtained from specialists in obstetrics and anaesthesia. Indications for endoscopy during pregnancy are as follows: (1) gastroscopy: upper gastrointestinal bleeding, dysphagia, uncontrolled nausea\\/vomiting; (2) sigmoidoscopy\\/colonoscopy: rectal bleeding, diarrhoea; and (3) ERCP: choledocholithiasis, biliary pancreatitis. Sedative drugs, such as midazolam appear to be safe if used carefully. Radiation exposure during ERCP can be kept well below the danger level for teratogenicity.

  6. Ingestible Wireless Capsule Technology: A Review of Development and Future Indication

    Directory of Open Access Journals (Sweden)

    M. R. Basar

    2012-01-01

    Full Text Available Ingestible wireless capsule endoscopy (WCE is the one and only painless, effective, novel, diagnostic technology for inspecting the entire gastrointestinal (GI tract for various diseases, such as obscure gastrointestinal bleeding (OGIB, tumors, cancer, Crohn’s disease, and celiac disease. Since the development of this technology, several companies have made remarkable improvements in their clinical products, but there are still some limitations that relate to the use of conventional wired endoscopy. Some of the major limitations that currently impede its wider application include its inability to repeat the view of critical areas, working time constraints, and poor image resolution. Many research groups currently are working on ways to solve these limitations. Presently, developing the ability to control the movement of the capsule, increasing its image transmission speed, and obtaining high-quality images are the main issues in the research area. A complex capsule with some therapeutic tools for the treatment of diseases of the GI tract also is at the beginning of development for the next generation of an active medical robot. In this paper, we report the status of several activities related to WCE, including improvement of capsule technology, research progress, technical challenges, and key indicators concerning the next-generation, active, medical robot.

  7. Virtual MR endoscopy of the ventricles prior to neurosurgical interventional endoscopy - evaluation of different presentation techniques

    International Nuclear Information System (INIS)

    Lemke, A.J.; Schurig-Urbaniak, A.M.; Niehues, S.M.; Felix, R.; Liebig, T.

    2004-01-01

    Purpose: In the past, virtual endoscopies have been performed for planning of endoscopic interventions or for diagnostic purposes in various organ systems with increasing frequency. This study evaluates the ability of virtual ventricular endoscopy to depict anatomical structures and the use for planning of real endoscopy. Materials and Methods: In a prospective study, 4 volunteers and 8 patients were examined with MRI. In 3 of the patients endoscopy was performed by our neurosurgeons thereafter. The calculation of the virtual endoscopy was based on 1 mm sagittal T2-weighted images. Comparison of surface rendering and volume rendering was made by means of video sequencing of individual views, and these were compared with the intraoperative endoscopic videos concerning the depictability of anatomical landmarks. Results: The reconstructions using volume rendering were more significant and easier to calculate than those based on surface rendering. Virtual endoscopy in the transparent mode allowed visualization of hazardous structures outside the ventricular system such as the basilar artery tip. Transparent 3D images of the ventricles gave a good overview on the depicted structures and enabled a better orientation during the virtual camera flight than surface rendered views. Conclusion: MR-based virtual endoscopy of the ventricular system can be obtained on the basis of surface- and volume-rendered views of sagittal T2-weighted thin sections. Preoperative utilization of this method simplifies the planning of endoscopy by visualization of anatomical structures. (orig.)

  8. The Endoscopy Global Rating Scale – Canada: Development And Implementation of a Quality Improvement Tool

    Directory of Open Access Journals (Sweden)

    Donald MacIntosh

    2013-01-01

    Full Text Available BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer.

  9. Small bowel endoluminal imaging (capsule and enteroscopy).

    Science.gov (United States)

    Murino, Alberto; Despott, Edward J

    2017-04-01

    Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice.

  10. Low power design of wireless endoscopy compression/communication architecture

    Directory of Open Access Journals (Sweden)

    Zitouni Abdelkrim

    2018-05-01

    Full Text Available A wireless endoscopy capsule represents an efficient device interesting on the examination of digestive diseases. Many performance criteria’s (silicon area, dissipated power, image quality, computational time, etc. need to be deeply studied.In this paper, our interest is the optimization of the indicated criteria. The proposed methodology is based on exploring the advantages of the DCT/DWT transforms by combining them into single architecture. For arithmetic operations, the MCLA technique is used. This architecture integrates also a CABAC entropy coder that supports all binarization schemes. AMBA/I2C architecture is developed for assuring optimized communication.The comparisons of the proposed architecture with the most popular methods explained in related works show efficient results in terms dissipated power, hardware cost, and computation speed. Keywords: Wireless endoscopy capsule, DCT/DWT image compression, CABAC entropy coder, AMBA/I2C multi-bus architecture

  11. Capsule-odometer: a concept to improve accurate lesion localisation.

    Science.gov (United States)

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  12. Wireless capsule endoscopy at Lagos State University Teaching ...

    African Journals Online (AJOL)

    Nigerian Journal of Gastroenterology and Hepatology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 5, No 1 (2013) >. Log in or Register to get access to full text downloads.

  13. Wireless capsule endoscopy as a tool in diagnosing autoimmune enteropathy

    DEFF Research Database (Denmark)

    Gram-Kampmann, Eva-Marie; Lillevang, Søren T; Detlefsen, Sönke

    2015-01-01

    Autoimmune enteropathy (AE) is an immune mediated illness of the intestinal mucosa. The cause is unknown, and the diagnosis is based on typical characteristics displayed. There is no gold standard for treatment. We present two adult cases of AE and demonstrate the challenges in establishing....... Use of WCE as a diagnostic tool was invaluable in establishing the diagnosis of AE....

  14. Motion analysis in terms of wireless video capsule endoscopy

    OpenAIRE

    Autengruber, Markus

    2009-01-01

    El treball presentat suposa una visió general de l'"Endoscopia amb Càpsula de Vídeo Wireless" i la inspecció de sequències de contraccions intestinals amb les últimes tecnologies de visió per computador. Després de la observació preliminar dels fonaments mèdics requerits, la aplicació de visió per computador es presenta en aquestos termes. En essència, aquest treball proveïx una exhaustiva selecció, descripció i avaluació de cert conjunt de mètodes de processament d'imatges respecte a l'anàli...

  15. "Endoview" project of intrapartum endoscopy.

    Science.gov (United States)

    Petrikovsky, Boris M; Ravens, Steven

    2002-01-01

    The change in obstetrical practices over the last decade in favor of trials of labor in patients with uterine scars has resulted in increased incidences of uterine ruptures. Although neither repeat cesarean delivery nor a trial of labor is risk free, evidence from a large multicenter study shows vaginal birth after the cesarean (VBAC) is associated with shorter hospital stays, fewer postpartum blood transfusions, and a decreased incidence of postpartum maternal fever. The uterine rupture remains the most serious complication associated with VBAC. Factors associated with uterine rupture include excessive exposure to oxytocin, dysfunctional labor, and a history of more than 1 cesarean delivery.2 Because uterine rupture may be a life-threatening event, intrapartum surveillance and the ability to perform an emergency surgery are both necessary when trial of labor is allowed. Until now, no early symptoms pathognomonic to uterine rupture had been described. We share our experiences with the novel approach to the problem - an intrapartum endoscopy. Endoscopic examination was accomplished by using the intraoperational fiberscope (Olympus and Endoview system (Costa Mesa, CA, USA). A gas-sterilized 25-cm long fiberscope is introduced into the amniotic cavity through the cervical canal after rupture of the membranes. The distance between the fiberscope and the object varies from 3 to 50 mm. The fiberscope has a separate channel for the fluid infusion (normal saline) throughout the procedure; the surgeon looks through the eyepiece directly and exhibits control over the flexible scope. The duration of endoscopy is less than 15 minutes. The inserting of the endoscopic device is very similar to that of insertion of an intrauterine pressure catheter. The IRB Committees of both participating institutions approved the study protocol. Twenty-eight patients with an unknown or poorly documented site of the uterine scar were included in the study. An ultrasound examination had been

  16. Endoscopy and surgery for obesity

    International Nuclear Information System (INIS)

    Mejia, Andres Felipe; Unigarro, Ivan; Bolanos, Eduardo; Chaux, Carlos Felipe

    2006-01-01

    Actually bariatric surgery appears to be a secure, feasible and durable option for patients with morbid obesity. Most of the complications that arise from bariatric surgery can be solved with the use of endoscopy avoiding the morbidity and mortality of a surgical intervention. This group of patients has become a challenge for the endoscopist and favours the development of interventional endoscopy

  17. Stray energy transfer during endoscopy.

    Science.gov (United States)

    Jones, Edward L; Madani, Amin; Overbey, Douglas M; Kiourti, Asimina; Bojja-Venkatakrishnan, Satheesh; Mikami, Dean J; Hazey, Jeffrey W; Arcomano, Todd R; Robinson, Thomas N

    2017-10-01

    Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.

  18. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  19. Real-time holographic endoscopy

    Science.gov (United States)

    Smigielski, Paul; Albe, Felix; Dischli, Bernard

    1992-08-01

    Some new experiments concerning holographic endoscopy are presented. The quantitative measurements of deformations of objects are obtained by the double-exposure and double- reference beam method, using either a cw-laser or a pulsed laser. Qualitative experiments using an argon laser with time-average holographic endoscopy are also presented. A video film on real-time endoscopic holographic interferometry was recorded with the help of a frequency-doubled YAG-laser working at 25 Hz for the first time.

  20. Swallowable capsule with air channel for improved image-guided cancer detection in the esophagus

    Science.gov (United States)

    Seibel, Eric J.; Melville, C. David; Lung, Jonathan K. C.; Babchanik, Alexander P.; Lee, Cameron M.; Johnston, Richard S.; Dominitz, Jason A.

    2009-02-01

    A new type of endoscope has been developed and tested in the human esophagus, a tethered-capsule endoscope (TCE) that requires no sedation for oral ingestion and esophageal inspection. The TCE uses scanned red, green, and blue laser light to image the upper digestive tract using a swallowable capsule of 6.4mm in diameter and 18mm in length on a 1.4mm diameter tether. The TCE has been modified for image-guided interventions in the lower esophagus, specifically for more effective detection and measurement of the extent of Barrett's esophagus, a precursor to esophageal cancer. Three modifications have been tested in vivo: (1) weighting the capsule so it is negatively buoyant in water, (2) increasing the frame rate of 500-line images to 30 Hz (video rate), and (3) adding a 1.0mm inner diameter working channel alongside the tether for distending the lower esophagus with air pressure during endoscopy. All three modifications proved effective for more clearly visualizing the lower esophagus in the first few human subjects. The air channel was especially useful because it did not change tolerability in the first subject for unsedated endoscopy and the air easily removed bubbles obscuring tissue from the field of view. The air provided a non-invasive intervention by stimulating the mechanosensor of the lower esophageal sphincter at the precise time that the TCE was positioned for most informative imaging. All three TCE modifications proved successful for improved visualization of esophageal pathology, such as suspected Barrett's esophagus, without the use of sedation.

  1. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  2. Monitoring of Intracranial Pressure During Intracranial Endoscopy

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar

    2013-08-01

    Full Text Available Background: Intracranial endoscopy is a minimum invasive procedure, which reduces trauma to the brain, is cost-effective, and carries a shortened hospital stay with an improved postoperative outcome. Objective: To monitor intracranial pressure changes during intracranial endoscopy among children and adults under general anesthesia/sedation, and to compare the intracranial pressure changes between children and adults receiving general anesthesia and among adults receiving general anesthesia and sedation. Methods: The present cross-sectional study was conducted in one of the tertiary care hospitals of Lucknow. This was carried out in the department of neurosurgery from January 2008 to December 2008. Patients who were not fit for general anesthesia received local anesthesia under sedation. Patients participating in the study were divided into three groups. Intracranial pressure was recorded at specific intervals. Parametric data were subjected to statistical analysis using a student\\s t test. Result: A total of 70 patients were undergoing intracranial endoscopy under general anesthesia during the study period. In both groups A and B, intracranial pressure increases the maximum during inflation of the balloon. In group C, all the variations in ICP were found to be statistically significant. In the comparison of intracranial pressure changes between groups A and B, no significant difference was found. All correlations in the comparison of groups B and C were found to be statistically significant (p< 0.001. Conclusion: There is a need for continuous intraoperative monitoring of ICP intracranial endoscopy, because ICP increases in various stages of the procedure, which can be detrimental to the perfusion of the brain. [Arch Clin Exp Surg 2013; 2(4.000: 240-245

  3. Wireless power and data transmission strategies for next-generation capsule endoscopes

    International Nuclear Information System (INIS)

    Puers, R; Carta, R; Thoné, J

    2011-01-01

    Capsular endoscopy is becoming increasingly popular as an alternative to traditional gastro-intestinal (GI) examination techniques. However, the breakthrough of these devices is hindered by the limited amount of power that can be stored in a tiny pill. Most commercial devices use two watch batteries that can only provide an average power of 25 mW for about 6 h, certainly not sufficient for advanced robotic features. A dedicated inductive powering system, operating at 1 MHz to limit the human body absorption, has been developed which was proven to support the transfer of over 300 mW. The system relies on a condensed set of orthogonal ferrite coils, embedded in the capsule, and an external unit based on a Helmholtz coil driven by a class E amplifier. Control data can be sent through the inductive link by modulating the power carrier, whereas a dedicated high data rate RF link is used to transfer the images from the capsule to the base station. Besides evaluating the compatibility with radio transmission, several demonstrators were assembled combining the wireless powering system with various locomotion strategies and LED illumination. This paper describes the design and implementation of the inductive powering system, its combination with data transmission techniques and the testing activity with other capsule-dedicated modules

  4. Microrobotics for future gastrointestinal endoscopy.

    Science.gov (United States)

    Menciassi, Arianna; Quirini, Marco; Dario, Paolo

    2007-01-01

    The impulse given by robotic technologies and imaging techniques to the development of a new way to conceive and perform surgery is clearly visible. Nowadays, minimally invasive surgical (MIS) procedures are often performed with the assistance of robots, such as the Da Vinci master-slave system, the AESOP robot with voice control, etc. In addition, mechatronic technologies are becoming the elective technologies for designing advanced hand-held surgical tools. The introduction of robotic technologies in endoscopy has been slower than in MIS, since the development of miniaturized robotic components for entering the small orifices of the human body is difficult. On the other hand, the large contribution that robotic technologies could bring to endoluminal techniques has been evident since the first development of instrumented catheters. In the 1990s, there was an increasing activity in the application of robotic technologies to improve endoscopic procedures in the gastrointestinal tract. The objective of robotic colonoscopy and gastroscopy was to obtain more effective diagnoses in terms of reduced pain for the patients, and to make uniform the diagnostic procedures, which too often depended on the manual abilities of the endoscopist. Currently, the availability of more reliable robotic technologies for miniaturization of size and integration of functions has allowed to conceive and develop robotic pills for the early screening of the digestive tract, with dramatic potential advantages for patients, endoscopists, and healthcare system.

  5. A literature review of quality in lower gastrointestinal endoscopy from the patient perspective

    OpenAIRE

    Sewitch, Maida J; Gong, Shasha; Dubé, Catherine; Barkun, Alan; Hilsden, Robert; Armstrong, David

    2011-01-01

    BACKGROUND: Given the limited state of health care resources, increased demand for colorectal cancer (CRC) screening raises concerns about the quality of endoscopy services. Little is known about quality in colonoscopy and endoscopy from the patient perspective.OBJECTIVE: To systematically review the literature on quality that is relevant to patients who require colonoscopy or endoscopy services.METHODS: A systematic PubMed search was performed on articles that were published between January ...

  6. upper gastrointestinal endoscopy findings in patients referred

    African Journals Online (AJOL)

    2014-08-01

    Aug 1, 2014 ... Objective: To determine the pattern of referral and endoscopy ... build a model of a flexible fibre imaging device (2) ..... a retrospective and prospective audit of all upper ... endoscopy should be reserved for the high risk.

  7. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  8. Chromoendoscopy and magnification endoscopy in Barrett's esophagus.

    Science.gov (United States)

    Connor, Michael J; Sharma, Prateek

    2003-04-01

    Chromoendoscopy and magnification endoscopy appear to be a valuable adjuncts for the detection and classification of BE. These techniques may also prove to be useful aids in surveillance protocols for identifying dysplastic epithelium or early cancer within a segment of BE. Ideally, the use of these techniques would enable the endoscopist to rule in or out the presence of IM and of dysplastic or cancerous epithelium by obtaining only a minimal number of targeted biopsy specimens, or potentially performing no biopsies at all. This could transform upper endoscopy into a much more effective screening and surveillance tool for BE. Several problems currently exist for the use of chromoendoscopy for BE. Results of studies reporting the accuracy of chromoendoscopy remain mixed,and are likely explained by the wide range of techniques and materials used in the investigations. Staining adds several steps, and likely several minutes, to an upper endoscopy. Staining within the esophagus is often patchy and uneven. In addition, poor spraying technique exaggerates the irregular uptake by the mucosa. There is a high false-positive rate when staining gastric-type epithelium and denuded epithelium. Areas of dysplasia or cancer may take up stain in an irregular manner, or may not stain at all. Chromoendoscopy is a relatively new technique in the management of BE and depends on the skill and experience of the endoscopist. Magnification, however, only allows the endoscopist to observe small areas of mucosa at a time, increasing the overall complexity and length of the procedure. The learning curve for this procedure is relatively short, however, and endoscopists can usually become proficient in the technique quickly. Currently, the greatest body of literature exists concerning the use of methylene blue for diagnosing BE. At the present time, chromoendoscopy and magnification endoscopy appear to be most beneficial in detecting IM in short segments of esophageal columnar

  9. From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.

    Science.gov (United States)

    Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas

    2016-12-01

    Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  11. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  12. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  13. Polydopamine-coated capsules

    Science.gov (United States)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen; Baginska, Marta B.

    2018-04-17

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  14. Colon Cancer Detection by ‘Rendezvous Colonoscopy’: Successful Removal of Stuck Colon Capsule by Conventional Colonoscopy

    Directory of Open Access Journals (Sweden)

    István Rácz

    2010-02-01

    Full Text Available Although capsule retention is a known complication of small bowel capsule endoscopy, initial studies with colon capsule endoscopy (CCE have not reported any capsule retention or sticking neither in the small bowel nor in the colon. We report a complication of CCE when the stuck colon capsule was passed through the malignant colon stricture and removed by the aid of a flexible colonoscope. During CCE in a 76-year-old iron deficiency anemia patient the real-time viewing system indicated the colon capsule to be stuck in a malignant ascending colon stricture for more than two hours. With the aim to avoid complete capsule retention, immediate colonoscopy was performed. The stuck capsule was caught by a polypectomy snare, passed through the tumor stricture and finally removed from the large bowel. The current case describes the usefulness of the real-time viewing system. Similar situations may occur during the forthcoming spread of CCE and the present case is an example of how to manage the potentially risky stuck colon capsule condition.

  15. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  16. A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule.

    Science.gov (United States)

    Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G

    2005-09-01

    The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.

  17. Improving the timeliness of procedures in a pediatric endoscopy suite.

    Science.gov (United States)

    Tomer, Gitit; Choi, Steven; Montalvo, Andrea; Sutton, Sheila; Thompson, John; Rivas, Yolanda

    2014-02-01

    Pediatric endoscopic procedures are essential in the evaluation and treatment of gastrointestinal diseases in children. Although pediatric endoscopists are greatly interested in increasing efficiency and through-put in pediatric endoscopy units, there is scarcely any literature on this critical process. The goal of this study was to improve the timeliness of pediatric endoscopy procedures at Children's Hospital at Montefiore. In June 2010, a pediatric endoscopy quality improvement initiative was formed at Children's Hospital at Montefiore. We identified patient-, equipment-, and physician-related causes for case delays. Pareto charts, cause and effect diagrams, process flow mapping, and statistical process control charts were used for analysis. From June 2010 to December 2012, we were able to significantly decrease the first case endoscopy delay from an average of 17 to 10 minutes (P < .001), second case delay from 39 to 25 minutes (P = .01), third case delay from 61 to 45 minutes (P = .05), and fourth case delay from 79 to 51 minutes (P = .05). Total delay time decreased from 196 to 131 minutes, resulting in a reduction of 65 minutes (P = .02). From June 2010 to August 2011 (preintervention period), an average of 36% of first endoscopy cases started within 5 minutes, 51% within 10 minutes, and 61% within 15 minutes of the scheduled time. From September 2011 to December 2012 (postintervention period), the percentage of cases starting within 5 minutes, 10 minutes, and 15 minutes increased to 47% (P = .07), 61% (P = .04), and 79% (P = .01), respectively. Applying quality improvement methods and tools helped improve pediatric endoscopy timeliness and significantly decreased total delays.

  18. Oxygen fugacity and piston cylinder capsule assemblies

    Science.gov (United States)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  19. Operative colonoscopic endoscopy.

    Science.gov (United States)

    Van Gossum, A; Bourgeois, F; Gay, F; Lievens, P; Adler, M; Cremer, M

    1992-01-01

    There are several conditions where operative colonoscopy is useful. Acute colonic pseudo-obstruction or Ogilvie's syndrome is characterized by a acute distension of the colon. Although medical management may be sufficient in many cases, endoscopic decompression must be performed when colonic distension is greater than 12 cm. Insertion of decompression tube to avoid rapid recurrence seems to be adequate. In case of massive lower intestinal hemorrhage, colonoscopy seems to be more accurate than mesenteric angiography. Such endoscopic examination requires an experienced endoscopist. Colonoscopic polypectomy has become the standard method for removal of colonic polyps. Factors influencing the rate of complications have been studied. While the number of complications was very low, we have observed that all the major hemorrhages were immediate when the blended current was used, but delayed when the pure coagulation current was applied. Endoscopic laser photocavitation is a valuable palliative method treating rectal adenocarcinoma in well selected patients. Indeed, if the patients survive sufficiently long after initial therapy, it becomes increasingly difficult to achieve persistent palliation with laser therapy.

  20. Adhesive capsulitis: review of imaging and treatment

    International Nuclear Information System (INIS)

    Harris, Guy; Bou-Haider, Pascal; Harris, Craig

    2013-01-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented.

  1. Diagnostic and Therapeutic Yield of Endoscopy in Patients with Elevated INR and Gastrointestinal Bleeding.

    Science.gov (United States)

    Peloquin, Joanna M; Seraj, Siamak M; King, Lindsay Y; Campbell, Emily J; Ananthakrishnan, Ashwin N; Richter, James M

    2016-06-01

    Gastrointestinal bleeding is a well-known risk of systemic anticoagulation. However, bleeding in the setting of supratherapeutic anticoagulation may have a milder natural history than unprovoked bleeding. It is a common clinical gestalt that endoscopy is common, but bleeding source identification or intervention is uncommon, yet few data exist to inform this clinical impression. Consequently, we sought to examine our institutional experience with gastrointestinal bleeding in the setting of supratherapeutic international normalized ratio (INR) with the aim of identifying predictors of endoscopically identifiable lesions, interventions, and outcomes. A retrospective review was conducted at a tertiary referral academic medical center to identify patients presenting with gastrointestinal bleeding in the setting of warfarin and a supratherapeutic INR (>3.5) who underwent an endoscopic procedure. Relevant clinical covariates, endoscopic findings, need for intervention, and outcomes were collected by review of the medical record. Logistic regression adjusting for potential confounders identified predictors of endoscopically significant lesions as well as intervention and outcomes. A total of 134 patients with INR 3.5 or greater (mean 5.5, range 3.5-17.1) presented with symptoms of gastrointestinal bleeding, most commonly as melena or symptomatic anemia. Antiplatelet agents were used by 54% of patients, and 60% of patients were on concomitant acid suppression on admission. Procedures included esophagogastroduodenoscopy (upper endoscopy; EGD) (n = 128), colonoscopy (n = 73), and video capsule endoscopy (n = 32). Active bleeding at first EGD or colonoscopy was found in only 19 patients (18%), with endoscopic intervention in only 26 patients (25%). At a critical threshold of INR 7.5 at presentation, the likelihood of finding an endoscopically significant lesion fell to therapy (odds ratio [OR] 2.59; 95% confidence interval [CI], 1.13-5.94), timing of EGD within 12 hours of

  2. Computerisation of endoscopy reports using standard reports and text blocks

    NARCIS (Netherlands)

    Groenen, M. J. M.; Kuipers, E. J.; van Berge Henegouwen, G. P.; Fockens, P.; Ouwendijk, R. J. Th

    2006-01-01

    BACKGROUND: The widespread use of gastrointestinal endoscopy for diagnosis and treatment requires effective, standardised report systems. This need is further increased by the limited storage of images, and by the need for structured databases for surveillance and epidemiology. We therefore aimed

  3. Novel disposable transnasal endoscopy for assessment of esophageal motor function.

    Science.gov (United States)

    Lim, Chul-Hyun; Choi, Myung-Gyu; Baeg, Myong-Ki; Moon, Sung Jin; Kim, Jin Su; Cho, Yu Kyung; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong

    2014-01-01

    A novel disposable transnasal endoscopy (DTE) with a portable system has been developed to provide unsedated esophagoscopy by modifying capsule endoscopy. The aim of this study was to assess the feasibility of DTE to evaluate esophageal motor function. Patients with or suspected esophageal motility disorders and healthy volunteers were enrolled. Participants underwent esophageal high-resolution manometry and DTE in random order on different days. Motility was observed with DTE at 1, 8, and 16 cm above the gastroesophageal junction. Twenty healthy volunteers and 20 symptomatic subjects participated (8 achalasia, 5 scleroderma, 3 diffuse esophageal spasm, 1 hypertensive peristalsis, 1 peristaltic dysfunction, and 22 normal esophageal function). The normal findings on DTE were as follows. As the subject swallowed water, swallow-induced relaxation with elevation of the lower esophageal sphincter caused the endoscope to cross the Z-line into the gastric lumen. After the passage of water and air, complete closure of the lower esophageal sphincter occurred, with the return of the endoscope to its previous position. During the resting stage of the esophageal body, an air bubble could be seen in the center of the radially wrinkled and occluded lumen. The endoscopic diagnosis was in agreement with the clinical diagnosis in all but 2. Most of the participants reported acceptable discomfort during DTE and 62.5% of the subjects preferred DTE to manometry. DTE can accurately characterize normal esophageal motor function, allowing the diagnosis of esophageal motility disorders. DTE has potential widespread applications, especially in outpatient clinics.

  4. Deep Learning in Gastrointestinal Endoscopy.

    Science.gov (United States)

    Patel, Vivek; Armstrong, David; Ganguli, Malika; Roopra, Sandeep; Kantipudi, Neha; Albashir, Siwar; Kamath, Markad V

    2016-01-01

    Gastrointestinal (GI) endoscopy is used to inspect the lumen or interior of the GI tract for several purposes, including, (1) making a clinical diagnosis, in real time, based on the visual appearances; (2) taking targeted tissue samples for subsequent histopathological examination; and (3) in some cases, performing therapeutic interventions targeted at specific lesions. GI endoscopy is therefore predicated on the assumption that the operator-the endoscopist-is able to identify and characterize abnormalities or lesions accurately and reproducibly. However, as in other areas of clinical medicine, such as histopathology and radiology, many studies have documented marked interobserver and intraobserver variability in lesion recognition. Thus, there is a clear need and opportunity for techniques or methodologies that will enhance the quality of lesion recognition and diagnosis and improve the outcomes of GI endoscopy. Deep learning models provide a basis to make better clinical decisions in medical image analysis. Biomedical image segmentation, classification, and registration can be improved with deep learning. Recent evidence suggests that the application of deep learning methods to medical image analysis can contribute significantly to computer-aided diagnosis. Deep learning models are usually considered to be more flexible and provide reliable solutions for image analysis problems compared to conventional computer vision models. The use of fast computers offers the possibility of real-time support that is important for endoscopic diagnosis, which has to be made in real time. Advanced graphics processing units and cloud computing have also favored the use of machine learning, and more particularly, deep learning for patient care. This paper reviews the rapidly evolving literature on the feasibility of applying deep learning algorithms to endoscopic imaging.

  5. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit

    Directory of Open Access Journals (Sweden)

    Rowena Almeida

    2016-01-01

    Full Text Available Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  6. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit.

    Science.gov (United States)

    Almeida, Rowena; Paterson, William G; Craig, Nancy; Hookey, Lawrence

    2016-01-01

    Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario) endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  7. Early Period Results and Clinical Characteristics of Upper Gastrointestinal Endoscopy in Sivrihisar State Hospital

    Directory of Open Access Journals (Sweden)

    Ozgur Turk

    2014-12-01

    Full Text Available Aim: Our aim was to identify the characteristics of the patient that performed upper gastrointestinal endoscopy in a new established endoscopy unit of a state hospital. We want to present the spectrum of gastrointestinal diseases in our hospitals region. Material and Method: We analyzed patients upper endoscopy results according to age, sex, complaints, clinical characteristics, type of anesthesia, and the necessity of biopsy. We reviewed 256 patients data between 2013 December-2014 July. All endoscopies were performed by same surgeon. Results: The highest complaint was epigastric pain (n=112, 43, 8%. Other complaints were followed as dyspepsia (n=84, 32.8%, heartburn (n=42, 16.4%, nausea (n=4, 1.6%, vomiting (n=2, 0.8%, dysphagia (n=6, 2.3%. We determined 218 gastritis (85.2%, 64 hiatal hernia (25%, 120 esophagitis (46.9%, 76 duodenitis (29.7%, 4 gastric ulcer (1.6%, 18 duodenal ulcers (7%, 20 bile reflux (7.8%, 26 Gastro esophageal reflux disease (GERD in patients (10.2%. 10 patients reported as normal (3.9%. Biopsy was performed in 186 of the patients. Discussion: Endoscopy can become an early diagnostic examination by increasing the availability of endoscopy. Also alarm symptoms should not be ignored and endoscopy should perform immediately in symptomatic patients. As an early result of upper gastrointestinal endoscopies that performed in this study; gastritis, esophagitis, duodenitis and hiatal hernia are common gastrointestinal diseases in our region.

  8. European Society of Gastrointestinal Endoscopy - Establishing the key unanswered research questions within gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Rees, Colin J; Ngu, Wee Sing; Regula, Jaroslaw

    2016-01-01

    Background and study aim: Gastrointestinal endoscopy is a rapidly evolving research field. The European Society of Gastrointestinal Endoscopy (ESGE) plays a key role in shaping opinion and endoscopy activity throughout Europe and further afield. Establishing key unanswered questions within the fi...

  9. Canadian Association of Gastroenterology consensus guidelines on safety and quality indicators in endoscopy.

    Science.gov (United States)

    Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Hollingworth, Roger; Macintosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J

    2012-01-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. The

  10. Unsedated Flexible Upper Gastrointestinal Endoscopy: Need for ...

    African Journals Online (AJOL)

    Background: To determine the incidence of oxygen desaturation and whether routine oxygen monitoring is necessary during unsedated diagnostic flexible upper gastrointestinal endoscopy. Methods: A prospective study involving 54 consecutive in and out patients who had diagnostic upper gastrointestinal endoscopy at ...

  11. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  12. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    Science.gov (United States)

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  13. Reporting systems in gastrointestinal endoscopy: Requirements and standards facilitating quality improvement: European Society of Gastrointestinal Endoscopy position statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality of gastrointestinal endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all gastrointestinal endoscopy procedures is

  14. Oral chlorhexidine and microbial contamination during endoscopy

    DEFF Research Database (Denmark)

    Donatsky, Anders Meller; Holzknecht, Barbara Juliane; Arpi, Magnus

    2013-01-01

    BACKGROUND: One of the biggest concerns associated with transgastric surgery is contamination and risk of intra-abdominal infection with microbes introduced from the access route. The purpose of this study was to evaluate the effect of oral decontamination with chlorhexidine on microbial contamin......BACKGROUND: One of the biggest concerns associated with transgastric surgery is contamination and risk of intra-abdominal infection with microbes introduced from the access route. The purpose of this study was to evaluate the effect of oral decontamination with chlorhexidine on microbial...... contamination of the endoscope. METHODS: In a prospective, randomized, single-blinded, clinical trial the effect of chlorhexidine mouth rinse was evaluated. As a surrogate for the risk of intra-abdominal contamination during transgastric surgery, microbial contamination of the endoscope during upper endoscopy...... microbial contamination of the endoscope, but micro-organisms with abscess forming capabilities were still present. PPI treatment significantly increased CFU and should be discontinued before transgastric surgery....

  15. Anesthesia related Complications in Pediatric GI Endoscopy

    Directory of Open Access Journals (Sweden)

    A Sabzevari

    2014-04-01

    Full Text Available Introduction: Elective upper and lower GI endoscopy is usually performed in children on an outpatient basis with the child under sedation or general anesthesia (GA. The objective of this study was to describe Anesthesia related complications in   children undergoing elective GI endoscopy.   Materials and Methods: The study design was descriptive on 1388 patients undergoing elective GI endoscopy in Sheikh Hospital from 2009 to 2013. All patient received propofol or standard inhalational anesthesia. We examined patients’ demographic data  ,  location of GI endoscopy ,  perioperative vital singe ,  recovery time , respiratory and cardiac complications , post operative nausea and vomiting , agitation , diagnosis and outcome   Results: Pediatric patients aged 2 to 17 years. 29 % of elective GI endoscopy was upper GI endoscopy and 70.3 % was lower GI endoscopy and 0.7 was both of them. 47.7 % of Pediatric patients were female and 52.3 % was male. We haven’t significant or fatal anesthesia related respiratory and cardiac complications (no apnea, no cardiac arrest. 8 patients (0.5% have transient bradicardia in post operative care Unit. 83 patients (5.9% have post operative nausea and vomiting controlled by medication.  6 patients (0.4% have post operative agitation controlled by medication.   Conclusions: General anesthesia and deep sedation in children undergoing elective GI endoscopy haven’t significant or fatal anesthesia related complications. We suggest Anesthesia for infants, young children, children with neurologic impairment, and some anxious older children undergoing elective GI endoscopy. Keyword: Anesthesia, Complication, Endoscopy, Pediatric.

  16. Capsule enteroscopy and radiology of the small intestine

    Energy Technology Data Exchange (ETDEWEB)

    Fork, Frans-Thomas [Malmoe University Hospital, Department of Diagnostic Radiology, Malmoe (Sweden); Aabakken, Lars [Rikshospitalet University Hospital, Department of Gastroenterology, Oslo (Norway)

    2007-12-15

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  17. Capsule enteroscopy and radiology of the small intestine

    International Nuclear Information System (INIS)

    Fork, Frans-Thomas; Aabakken, Lars

    2007-01-01

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  18. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  19. Non-destructive tests of capsules for JMTR irradiation examination

    International Nuclear Information System (INIS)

    Tanaka, Hidetaka; Nagao, Yoshiharu; Sato, Masashi; Osawa, Kenji

    2007-03-01

    Irradiation examination are increasing in advanced irradiation research for accurate prediction control and evaluation of irradiation parameter such as neutron fluence, etc. by using JMTR. Irradiation capsule internals are therefore structurally complicated recently. This report described the procedure of non destructive tests such as radiographic test, penetrant test, ultrasonic test, etc. for inspection of irradiation capsules in JMTR, and the result of Test-case of confirmation procedure for internal parts of irradiation capsules. (author)

  20. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  1. Polar tent for reduced perturbation of NIF ignition capsules

    Science.gov (United States)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  2. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  3. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  4. Leadership and team building in gastrointestinal endoscopy.

    Science.gov (United States)

    Valori, Roland M; Johnston, Deborah J

    2016-06-01

    A modern endoscopy service delivers high volume procedures that can be daunting, embarrassing and uncomfortable for patients [1]. Endoscopy is hugely beneficial to patients but only if it is performed to high standards [2]. Some consequences of poor quality endoscopy include worse outcomes for cancer and gastrointestinal bleeding, unnecessary repeat procedures, needless damage to patients and even avoidable death [3]. New endoscopy technology and more rigorous decontamination procedures have made endoscopy more effective and safer, but they have placed additional demands on the service. Ever-scarcer resources require more efficient, higher turnover of patients, which can be at odds with a good patient experience, and with quality and safety. It is clear from the demands put upon it, that to deliver a modern endoscopy service requires effective leadership and team working [4]. This chapter explores what constitutes effective leadership and what makes great clinical teams. It makes the point that endoscopy services are not usually isolated, independent units, and as such are dependent for success on the organisations they sit within. It will explain how endoscopy services are affected by the wider policy and governance context. Finally, within the context of the collection of papers in this edition of Best Practice & Research: Clinical Gastroenterology, it explores the potentially conflicting relationship between training of endoscopists and service delivery. The effectiveness of leadership and teams is rarely the subject of classic experimental designs such as randomized controlled trials. Nevertheless there is a substantial literature on this subject within and particularly outside healthcare [5]. The authors draw on this wider, more diffuse literature and on their experience of delivering a Team Leadership Programme (TLP) to the leaders of 70 endoscopy teams during the period 2008-2012. (Team Leadership Programme Link-http

  5. Risk Management for Gastrointestinal Endoscopy in Elderly Patients: Questionnaire for Patients Undergoing Gastrointestinal Endoscopy

    OpenAIRE

    Umegaki, Eiji; Abe, Shinya; Tokioka, Satoshi; Takeuchi, Nozomi; Takeuchi, Toshihisa; Yoda, Yukiko; Murano, Mitsuyuki; Higuchi, Kazuhide

    2009-01-01

    More elderly patients now undergo gastrointestinal endoscopy following recent advances in endoscopic techniques. In this study, we conducted a high-risk survey of endoscopies in Japan, using a questionnaire administered prior to upper gastrointestinal tract endoscopy (UGITE), and identified anticholinergic agents and glucagon preparations as high-risk premedication. We also evaluated the cardiovascular effects of anticholinergic agents and glucagon through measurements of plasma levels of hum...

  6. Appropriateness of Referrals for Upper Gastrointestinal Endoscopy ...

    African Journals Online (AJOL)

    Appropriateness of Referrals for Upper Gastrointestinal Endoscopy. ... Accra between January and December, 2008 were interviewed and evaluated for this study. ... Presentations with bleeding and suspicion of malignancy showed statistical ...

  7. Motion Analysis for Duplicate Frame Removal in Wireless Capsule Endoscope Video

    OpenAIRE

    Min Kook Choi; Hyun Gyu Lee; Ryan You; Byeong-Seok Shin; Sang-Chul Lee

    2010-01-01

    Wireless capsule Endoscopy (WCE) has rapidly shown its wide applications in medical domain last ten years thanks to its noninvasiveness for patients and support for thorough inspection through a patient-s entire digestive system including small intestine. However, one of the main barriers to efficient clinical inspection procedure is that it requires large amount of effort for clinicians to inspect huge data collected during the examination, i.e., over 55,000 frames in vi...

  8. Endoscopy and sedation: an inseparable binomial for the gastroenterologist.

    Science.gov (United States)

    Crespo, Javier; Terán, Álvaro

    2018-04-01

    The development of endoscopy and its increasing demand among the population have led to a growing need for propofol-based sedation techniques. Benefit is indisputable for both patients and endoscopists, but some aspects require considering the "who" and "how" of sedation as related to safety and health care costs. Propofol is first-choice in endoscopy for the European Society of Gastrointestinal Endoscopy because of its fast onset of action and short half-life, and many reports exist on its safety when used by gastroenterologists rather than anesthesiologists. In this issue of REED several originals support the efficiency and safety of propofol even for complex, high-risk, or protracted procedures such as endoscopic retrograde cholangiopancreatography (ERCP) and enteroscopy. Propofol may be safely and effectively administered by a team with specific skills acquired through education and using a specific procedure. However, difficulties arise in real-world clinical practice that preclude such training, which in Spain should be included in the MIR (médico interno residente) specialization program curriculum. The Comisión Nacional de Digestivo (Spanish National Commission on Digestive Diseases), sensitive to this training gap, has included in their latest version of the MIR program (under assessment) four additional competences, with number 145 (training in deep sedation) being most relevant here. In addition, the Spanish Society of Gastrointestinal Endoscopy (SEED) has invested significant efforts in sedation training, with over 50 courses on sedation for endoscopists and nurses. Continuing education and training in this field (for instance, refresher courses on advanced cardiopulmonary resuscitation) should be a goal for all endoscopy units. Because of the diversity found among hospitals, with single or multiple endoscopy rooms, efforts should be made to persuade those in charge of gastroenterology and anesthesiology departments to establish the necessary care

  9. The endoscopy Global Rating Scale – Canada: Development and implementation of a quality improvement tool

    Science.gov (United States)

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George

    2013-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242

  10. The endoscopy Global Rating Scale-Canada: development and implementation of a quality improvement tool.

    Science.gov (United States)

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; Veldhuyzen van Zanten, Sander; Daniels, Sandra; Ghattas, George

    2013-02-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes⁄no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide.

  11. [Sedation with intravenous midazolam during upper gastrointestinal endoscopy--changes in hemodynamics, oxygen saturation and memory].

    Science.gov (United States)

    Mizuno, Ju; Matsuki, Michiko; Gouda, Yoshinori; Nishiyama, Tomoki; Hanaoka, Kazuo

    2003-09-01

    Cardiorespiratory adverse effects are often observed in patients undergoing upper gastrointestinal endoscopy with sedation. In this study, we examined hemodynamics, oxygen saturation and memory during upper gastrointestinal endoscopy under sedation with intravenous midazolam. Eight healthy outpatients without any obvious complications received intravenous midazolam 5 mg for sedation for upper gastrointestinal endoscopy. Blood pressure, heart rate and percutaneous arterial oxygen saturation (SpO2) were measured before, during and after endoscopy. After the arousal by intravenous flumazenil, we inquired the patients about the level of memory during the endoscopy. Blood pressure decreased significantly two minutes after midazolam administration, but increased significantly after the insertion of an endoscope which was not different from the control value. Heart rate increased significantly one and three minutes after the insertion of the endoscope. SpO2 decreased significantly after midazolam administration and stayed at around 95%. No patients remembered the procedure. Sedation with intravenous midazolam during upper gastrointestinal endoscopy is useful to control the cardiovascular responses, and to obtain amnesia. However, a decrease in SpO2 should be watched carefully.

  12. Reinforcing effects of caffeine in coffee and capsules.

    Science.gov (United States)

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  13. High temperature radioisotope capsule

    International Nuclear Information System (INIS)

    Bradshaw, G.B.

    1976-01-01

    A high temperature radioisotope capsule made up of three concentric cylinders, with the isotope fuel located within the innermost cylinder is described. The innermost cylinder has hemispherical ends and is constructed of a tantalum alloy. The intermediate cylinder is made of a molybdenum alloy and is capable of withstanding the pressure generated by the alpha particle decay of the fuel. The outer cylinder is made of a platinum alloy of high resistance to corrosion. A gas separates the innermost cylinder from the intermediate cylinder and the intermediate cylinder from the outer cylinder

  14. Factors affecting capsule size and production by lactic acid bacteria used as dairy starter cultures.

    Science.gov (United States)

    Hassan, A N; Frank, J F; Shalabi, S I

    2001-02-28

    The effects of sugar substrates on capsule size and production by some capsule-forming nonropy and ropy dairy starter cultures were studied. Test sugars (glucose, lactose, galactose, or sucrose) were used as a sole carbohydrate source and the presence of a capsule and its size were determined by using confocal scanning laser microscopy. Nonropy strains produced maximum capsule size when grown in milk. Strains that did not produce capsules in milk did not produce them in any other growth medium. Specific sugars required for capsule production were strain-dependent. Increasing lactose content of Elliker broth from 0.5 to 5% or adding whey protein or casein digest produced larger capsules. Whey protein concentrate stimulated production of larger capsules than did casamino acids or casitone. Some Streptococcus thermophilus strains produced capsules when grown on galactose only. Nonropy strains of Lactobacillus delbrueckii subsp. bulgaricus produced capsules on lactose, but not on glucose. A ropy strain of Lactobacillus delbrueckii subsp. bulgaricus produced a constant capsule size regardless of the growth medium. The ability of some strains of Streptococcus thermophilus to use galactose in capsule production could reduce browning of mozzarella cheese during baking by removing a source of reducing sugar. Media that do not support capsule production may improve cell harvesting.

  15. Advanced Therapeutic Gastrointestinal Endoscopy in Children – Today and Tomorrow

    Directory of Open Access Journals (Sweden)

    Zaheer Nabi

    2018-03-01

    Full Text Available Gastrointestinal (GI endoscopy plays an indispensable role in the diagnosis and management of various pediatric GI disorders. While the pace of development of pediatric GI endoscopy has increased over the years, it remains sluggish compared to the advancements in GI endoscopic interventions available in adults. The predominant reasons that explain this observation include lack of formal training courses in advanced pediatric GI interventions, economic constraints in establishing a pediatric endoscopy unit, and unavailability of pediatric-specific devices and accessories. However, the situation is changing and more pediatric GI specialists are now performing complex GI procedures such as endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography for various pancreatico-biliary diseases and more recently, per-oral endoscopic myotomy for achalasia cardia. Endoscopic procedures are associated with reduced morbidity and mortality compared to open surgery for GI disorders. Notable examples include chronic pancreatitis, pancreatic fluid collections, various biliary diseases, and achalasia cardia for which previously open surgery was the treatment modality of choice. A solid body of evidence supports the safety and efficacy of endoscopic management in adults. However, additions continue to be made to literature describing the pediatric population. An important consideration in children includes size of children, which in turn determines the selection of endoscopes and type of sedation that can be used for the procedure.

  16. Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection

    Directory of Open Access Journals (Sweden)

    Bianca Regeling

    2016-08-01

    Full Text Available Hyperspectral imaging (HSI is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope’s fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details.

  17. Virtual reality simulators for gastrointestinal endoscopy training.

    Science.gov (United States)

    Triantafyllou, Konstantinos; Lazaridis, Lazaros Dimitrios; Dimitriadis, George D

    2014-01-16

    The use of simulators as educational tools for medical procedures is spreading rapidly and many efforts have been made for their implementation in gastrointestinal endoscopy training. Endoscopy simulation training has been suggested for ascertaining patient safety while positively influencing the trainees' learning curve. Virtual simulators are the most promising tool among all available types of simulators. These integrated modalities offer a human-like endoscopy experience by combining virtual images of the gastrointestinal tract and haptic realism with using a customized endoscope. From their first steps in the 1980s until today, research involving virtual endoscopic simulators can be divided in two categories: investigation of the impact of virtual simulator training in acquiring endoscopy skills and measuring competence. Emphasis should also be given to the financial impact of their implementation in endoscopy, including the cost of these state-of-the-art simulators and the potential economic benefits from their usage. Advances in technology will contribute to the upgrade of existing models and the development of new ones; while further research should be carried out to discover new fields of application.

  18. Non-technical skills and gastrointestinal endoscopy: a review of the literature.

    Science.gov (United States)

    Hitchins, Charlotte R; Metzner, Magdalena; Edworthy, Judy; Ward, Catherine

    2018-04-01

    Non-technical skills (NTS) have gained increasing recognition in recent years for their role in safe, effective team performance in healthcare. Gastrointestinal endoscopy is a procedure-based specialty with rapidly advancing technology, significant operational pressures and rapidly changing 'teams of experts'. However, to date there has been little focus on the effect of NTS in this field. This review aims to examine the existing literature on NTS in gastrointestinal endoscopy and identify areas for further research. A systematic search of MEDLINE, Embase, Cochrane Library, PsychINFO, CINAHL Plus and PubMed databases was performed using search terms Non-Technical Skills, Team Performance or Team Skills, and Endoscopy, Colonoscopy, OGD, Gastroscopy, Endoscopic Retrograde Cholangio-Pancreatography or Endoscopic Ultrasound. Eighteen relevant publications were found. NTS are deemed an essential component of practice, but so far there is little evidence of their integration into training or competency assessment. Those studies examining the effects of NTS and team training in endoscopy are small and have variable outcome measures with limited evidence of improvement in skills or clinical outcomes. NTS assessment in endoscopy is in its early phases with a few tools in development. The current literature on NTS in gastrointestinal endoscopy is limited. NTS, however, are deemed an essential component of practice, with potential positive effects on team performance and clinical outcomes. A validated reliable tool would enable evaluation of training and investigation into the effects of NTS on outcomes. There is a clear need for further research in this field.

  19. Abdominal compression during endoscopy (the Bolster technique) demonstrates hidden Schatzki rings (with videos).

    Science.gov (United States)

    Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises

    2016-05-01

    Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Arteriovenous Malformation Detected by Small Bowel Endoscopy

    Directory of Open Access Journals (Sweden)

    Takaaki Fujii

    2014-10-01

    Full Text Available Gastrointestinal bleeding that originates in the small intestine is often difficult to diagnose. When successful diagnosis reveals a lesion that can be localized preoperatively, the laparoscopic approach is an appropriate and beneficial treatment modality for small bowel resection. A 69-year-old man presented with a 6-month history of gastrointestinal bleeding and symptomatic transfusion-dependent anemia. Upper and lower endoscopy were normal. Double-balloon endoscopy established the source of the bleeding as a 0.5-cm polypoid mass appearing as a submucosal tumor with redness and pulsation in the lower ileum, suggesting a vascular lesion. Laparoscopic small bowel resection was successful in removing the mass in the ileum. Histological evaluation of the mass revealed an arteriovenous malformation. Preoperative small bowel endoscopy can be useful for diagnosing the cause and localization of arteriovenous malformation in the small intestine.

  1. Classification of videocapsule endoscopy image patterns: comparative analysis between patients with celiac disease and normal individuals

    Directory of Open Access Journals (Sweden)

    Ciaccio Edward J

    2010-09-01

    Full Text Available Abstract Background Quantitative disease markers were developed to assess videocapsule images acquired from celiac disease patients with villous atrophy, and from control patients. Method Capsule endoscopy videoclip images (576 × 576 pixels were acquired at 2/second frame rate (11 celiacs, 10 controls at regions: 1. bulb, 2. duodenum, 3. jejunum, 4. ileum and 5. distal ileum. Each of 200 images per videoclip (= 100s were subdivided into 10 × 10 pixel subimages for which mean grayscale brightness level and its standard deviation (texture were calculated. Pooled subimage values were grouped into low, intermediate, and high texture bands, and mean brightness, texture, and number of subimages in each band (nine features in all were used for quantifying regions 1-5, and to determine the three best features for threshold and incremental learning classification. Classifiers were developed using 6 celiac and 5 control patients' data as exemplars, and tested on 5 celiacs and 5 controls. Results Pooled from all regions, the threshold classifier had 80% sensitivity and 96% specificity and the incremental classifier had 88% sensitivity and 80% specificity for predicting celiac versus control videoclips in the test set. Trends of increasing texture from regions 1 to 5 occurred in the low and high texture bands in celiacs, and the number of subimages in the low texture band diminished (r2 > 0.5. No trends occurred in controls. Conclusions Celiac videocapsule images have textural properties that vary linearly along the small intestine. Quantitative markers can assist in screening for celiac disease and localize extent and degree of pathology throughout the small intestine.

  2. Helicobacter pylori as an occupational hazard in the endoscopy room

    African Journals Online (AJOL)

    South African Journal of Surgery ... Background: It remains controversial whether or not healthcare workers on upper ... We were unable to confirm that endoscopy was a risk factor for endoscopy teams with regard to contracting H. pylori.

  3. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2009-01-01

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  4. Effect of Heat Flux on the Specimen Temperature of an LBE Capsule

    International Nuclear Information System (INIS)

    Kang, Y. H.; Park, S. J.; Cho, M. S.; Choo, K. N.; Lee, Y. S.

    2011-01-01

    For application of high-temperature irradiation tests in the HANARO reactor for Gen IV reactor material development, a number of newly designed LBE capsules have been investigated at KAERI since 2008. Recent study on heat transfer experiment of an LBE capsule with a single heater has shown that the specimen temperature of the mock-up increased linearly with an increase of heat input. The work highlighted only the heat transfer capability of an LBE capsule with a single heater as a simulated specimen in a liquid metal medium. Hence, a new LBE capsule with multi specimen sets has been designed and fabricated for the heat transfer experiment of an LBE capsule of 11M-01K. In this paper, a series of thermal analyses and heat transfer experiments for a newly designed LBE capsule was implemented to study the effect of an increase in the value of heat input and its influence on temperature distribution in the capsule mock-up

  5. Biosorption of mercury by capsulated and slime layer- forming Gram ...

    African Journals Online (AJOL)

    ONOS

    2010-09-20

    Sep 20, 2010 ... high negatively charged components, showed more than 1.5 fold increase as compared to capsulated ... Mercury is one of the most toxic heavy metals released in ... ion exchange, activated carbon adsorption and separation.

  6. Upper Gastro-intestinal'Fibre-Optic Endoscopy

    African Journals Online (AJOL)

    1974-04-27

    Apr 27, 1974 ... A 3-YEAR STUDY AT GROOTE SCHUUR HOSPITAL. B. H. NOVIS, S. BANK, 1. .... ever, in 142 cases endoscopy provided a more definitive diagnosis or .... the best interests of the particular patient, related to the facilities and ...

  7. Transnasal endoscopy: Technical considerations, advantages and limitations.

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-02-16

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes.

  8. Hindfoot endoscopy for posterior ankle pain

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies, most of which can be diagnosed and treated with endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a longitudinal peroneus brevis rupture, peroneal tendon adhesiolysis, flexor hallucis longus release, os

  9. Virtual endoscopy in neurosurgery: a review.

    Science.gov (United States)

    Neubauer, André; Wolfsberger, Stefan

    2013-01-01

    Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.

  10. Transnasal endoscopy: Technical considerations, advantages and limitations

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-01-01

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes. PMID:24567791

  11. Comparative evaluation of esophageal Barrett's epithelium through esophageal capsule endoscopy and methylene blue chromoendoscop

    Directory of Open Access Journals (Sweden)

    T.A. Domingos

    2013-04-01

    Conclusions: ECE appears to be a good method for detecting lesions in which there is suspicion of esophageal cancer and it had modest results in regard to the accurate identification of BE length and pattern. ECE is not a good method for detecting hiatal hernia. Further studies are needed in order to define the definitive role of ECE in BE monitoring.

  12. Characterisation of two AGATA asymmetric high purity germanium capsules

    International Nuclear Information System (INIS)

    Colosimo, S.J.; Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S.; Lazarus, I.H.; Nolan, P.J.; Simpson, J.; Unsworth, C.

    2015-01-01

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array

  13. Characterisation of two AGATA asymmetric high purity germanium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Colosimo, S.J., E-mail: sjc@ns.ph.liv.ac.uk [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Nolan, P.J. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Unsworth, C. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2015-02-11

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array.

  14. Requirements and standards facilitating quality improvement for reporting systems in gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality in gastrointestinal (GI) endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all GI endoscopy procedures is state-of-the-art

  15. Upper gastrointestinal endoscopy in children: The Lagos University Teaching Hospital experience

    Directory of Open Access Journals (Sweden)

    Oluwafunmilayo Funke Adeniyi

    2016-12-01

    Full Text Available Background. Paediatric endoscopy is now standard care in the developed world for the management of gastrointestinal (GI disorders. However, in developing countries endoscopy remains an underutilised tool. Objective. To determine the indications and the spectrum of endoscopic findings in children seen at the Lagos University Teaching Hospital, Nigeria. Methods. The indications for upper GI endoscopy and endoscopic findings in children ≤16 years old, referred for the procedure from June 2013 to June 2016, were documented. The endoscopic yield in these children was also determined. Results. In total 71 children were referred for upper GI endoscopy during the study period. There were 35 boys and 36 girls aged 3 months to 16 years. The indications for upper endoscopy were recurrent abdominal pain in 37 (52.1%, upper GI bleeding in 17 (23.9%, recurrent vomiting in 7 (9.9%, dyspepsia in 5 (7.0, heartburn in 2 (2.8%, dysphagia in 1 (1.4, portal hypertension in 1 (1.4 and ingestion of corrosives in 1 (1.4% of the subjects. Endoscopic findings were as follows: gastritis 19 (26.8%, hiatus hernia in 13 (18.3%, gastric erosions in 12 (16.9%, oesophageal varices 6 (8.4%, duodenitis in 4 (5.6%, gastric ulcer in 3 (4.2%, gastric polyp in 2 (2.8%. The overall endoscopic yield was 60.2%. Conclusion. There is a need to increase the awareness of the role of paediatric endoscopy in the diagnosis and treatment of GI disorders in developing countries. Recurrent abdominal pain still remains a relevant indication for the procedure. The need to develop training programmes for paediatric endoscopy and paediatric gastroenterology in general in developing countries cannot be overemphasised.

  16. Soft gelatin capsules (softgels).

    Science.gov (United States)

    Gullapalli, Rampurna Prasad

    2010-10-01

    It is estimated that more than 40% of new chemical entities (NCEs) coming out of the current drug discovery process have poor biopharmaceutical properties, such as low aqueous solubility and/or permeability. These suboptimal properties pose significant challenges for the oral absorption of the compounds and for the development of orally bioavailable dosage forms. Development of soft gelatin capsule (softgel) dosage form is of growing interest for the oral delivery of poorly water soluble compounds (BCS class II or class IV). The softgel dosage form offers several advantages over other oral dosage forms, such as delivering a liquid matrix designed to solubilize and improve the oral bioavailability of a poorly soluble compound as a unit dose solid dosage form, delivering low and ultra-low doses of a compound, delivering a low melting compound, and minimizing potential generation of dust during manufacturing and thereby improving the safety of production personnel. However, due to the very dynamic nature of the softgel dosage form, its development and stability during its shelf-life are fraught with several challenges. The goal of the current review is to provide an in-depth discussion on the softgel dosage form to formulation scientists who are considering developing softgels for therapeutic compounds.

  17. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Yamaura, Takayuki; Nagao, Yoshiharu

    2013-01-01

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  18. Endoscopy and antiplatelet agents. European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    Science.gov (United States)

    Boustière, C; Veitch, A; Vanbiervliet, G; Bulois, P; Deprez, P; Laquiere, A; Laugier, R; Lesur, G; Mosler, P; Nalet, B; Napoleon, B; Rembacken, B; Ajzenberg, N; Collet, J P; Baron, T; Dumonceau, J-M

    2011-05-01

    With the increasing use of antiplatelet agents (APA), their management during the periendoscopic period has become a more common and more difficult problem. The increase in use is due to the availability of new drugs and the widespread use of drug-eluting coronary stents. Acute coronary syndromes can occur when APA therapy is withheld for noncardiovascular interventions. Guidelines about APA management during the periendoscopic period are traditionally based on assessments of the procedure-related risk of bleeding and the risk of thrombosis if APA are stopped. New data allow better assessment of these risks, of the necessary duration of APA discontinuation before endoscopy, of the use of alternative procedures (mostly for endoscopic retrograde cholangiopancreatography [ERCP]), and of endoscopic methods that can be used to prevent bleeding (following colonic polypectomy). This guideline makes graded, evidence-based, recommendations for the management of APA for all currently performed endoscopic procedures. A short summary and two tables are included for quick reference. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Dynamics of an elastic capsule in moderate Reynolds number Poiseuille flow

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Sung, Hyung Jin

    2012-01-01

    Highlights: ► Dynamics of a capsule in moderate Re Poiseuille flow were explored numerically. ► Capsule tends to tumbling motion for larger membrane elasticity and higher Re flow. ► Capsule undergoes swinging motion for larger size and aspect ratio of the capsule. ► Capsule tends to migrate to a specific lateral equilibrium as Re increases. ► Equilibrium position varies differently around the transition of the dynamic motion. - Abstract: The dynamic motions and lateral equilibrium positions of a two-dimensional elastic capsule in a Poiseuille flow were explored at moderate Reynolds number (10 ⩽ Re ⩽ 100) as a function of the initial lateral position (y 0 ), Re, aspect ratio (ε), size ratio (λ), membrane stretching coefficient (φ) and bending coefficient (γ). The transition between tank-treading (TT) and swinging (SW) to tumbling (TU) motions was observed and the lateral equilibrium positions of the capsules varied according to the conditions. The initial behavior of the elastic capsule was influenced by variation in the initial lateral position (y 0 ), but the equilibrium position and dynamic motion of the capsule were not affected by such variation. The capsules had a stronger tendency toward TU motion at higher values of Re, φ and γ, whereas the capsules underwent TT or SW motion as the values of ε and λ increased. Under moderate Re Poiseuille flows, capsules tended to migrate across streamlines to a specific equilibrium position. The lateral equilibrium position shifted toward the centerline at larger λ and migrated toward the wall at larger ε,φandγ. As Re increased, the equilibrium position first shifted toward the bottom wall, then toward the channel center. However, different equilibrium position trends were obtained around the SW–TU transition. The capsule undergoing TU motion tended to migrate downward toward the bottom wall more than the capsule undergoing SW motion, all other conditions being similar.

  20. Unmeasured improvement work: the lack of routinely collected, service-related data in NHS endoscopy units in England involved in "modernisation"

    Directory of Open Access Journals (Sweden)

    Hutchings Hayley A

    2008-01-01

    changes. With the increasing pressures placed on NHS endoscopy services, the need to effectively inform redesign plans is paramount. We recommend the compulsory collection of service-related endoscopy data by all NHS endoscopy units using a standardised format with rigorous guidelines.

  1. Assessment of patency capsule retention using MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne [Sheba Medical Center, Department of Diagnostic Imaging, Ramat Gan (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami [Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Sheba Medical Center, Department of Gastroenterology, Ramat Gan (Israel)

    2017-12-15

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm{sup 2}/s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  2. Assessment of patency capsule retention using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne; Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami

    2017-01-01

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm 2 /s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  3. Sedation-related complications in gastrointestinal endoscopy

    OpenAIRE

    Amornyotin, Somchai

    2013-01-01

    Sedation practices for gastrointestinal endoscopic (GIE) procedures vary widely in different countries depending on health system regulations and local circumstances. The goal of procedural sedation is the safe and effective control of pain and anxiety, as well as to provide an appropriate degree of memory loss or decreased awareness. Sedation-related complications in gastrointestinal endoscopy, once occurred, can lead to significant morbidity and occasional mortality in patients. The risk fa...

  4. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    Science.gov (United States)

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  5. Quality Improvement in Pediatric Endoscopy: A Clinical Report From the NASPGHAN Endoscopy Committee.

    Science.gov (United States)

    Kramer, Robert E; Walsh, Catharine M; Lerner, Diana G; Fishman, Douglas S

    2017-07-01

    The current era of healthcare reform emphasizes the provision of effective, safe, equitable, high-quality, and cost-effective care. Within the realm of gastrointestinal endoscopy in adults, renewed efforts are in place to accurately define and measure quality indicators across the spectrum of endoscopic care. In pediatrics, however, this movement has been less-defined and lacks much of the evidence-base that supports these initiatives in adult care. A need, therefore, exists to help define quality metrics tailored to pediatric practice and provide a toolbox for the development of robust quality improvement (QI) programs within pediatric endoscopy units. Use of uniform standards of quality reporting across centers will ensure that data can be compared and compiled on an international level to help guide QI initiatives and inform patients and their caregivers of the true risks and benefits of endoscopy. This report is intended to provide pediatric gastroenterologists with a framework for the development and implementation of endoscopy QI programs within their own centers, based on available evidence and expert opinion from the members of the NASPGHAN Endoscopy Committee. This clinical report will require expansion as further research pertaining to endoscopic quality in pediatrics is published.

  6. Impact of operator fatigue on endoscopy performance: implications for procedure scheduling.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2009-08-01

    With increasing volumes of endoscopic procedures, endoscopists\\' workload has had to increase to meet this escalating demand. The aim of this study was to characterize the impact of endoscopist fatigue on quality of endoscopy performance by comparing outcomes based on chronological procedure order.

  7. Development of CMOS Imager Block for Capsule Endoscope

    International Nuclear Information System (INIS)

    Shafie, S; Fodzi, F A M; Tung, L Q; Lioe, D X; Halin, I A; Hasan, W Z W; Jaafar, H

    2014-01-01

    This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5 V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5 V to 3.3 V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5 V to 3.3 V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.

  8. Motion analysis for duplicate frame removal in wireless capsule endoscope

    Science.gov (United States)

    Lee, Hyun-Gyu; Choi, Min-Kook; Lee, Sang-Chul

    2011-03-01

    Wireless capsule endoscopy (WCE) has been intensively researched recently due to its convenience for diagnosis and extended detection coverage of some diseases. Typically, a full recording covering entire human digestive system requires about 8 to 12 hours for a patient carrying a capsule endoscope and a portable image receiver/recorder unit, which produces 120,000 image frames on average. In spite of the benefits of close examination, WCE based test has a barrier for quick diagnosis such that a trained diagnostician must examine a huge amount of images for close investigation, normally over 2 hours. The main purpose of our work is to present a novel machine vision approach to reduce diagnosis time by automatically detecting duplicated recordings caused by backward camera movement, typically containing redundant information, in small intestine. The developed technique could be integrated with a visualization tool which supports intelligent inspection method, such as automatic play speed control. Our experimental result shows high accuracy of the technique by detecting 989 duplicate image frames out of 10,000, equivalently to 9.9% data reduction, in a WCE video from a real human subject. With some selected parameters, we achieved the correct detection ratio of 92.85% and the false detection ratio of 13.57%.

  9. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  10. A Near-Lossless Image Compression Algorithm Suitable for Hardware Design in Wireless Endoscopy System

    Directory of Open Access Journals (Sweden)

    Xie Xiang

    2007-01-01

    Full Text Available In order to decrease the communication bandwidth and save the transmitting power in the wireless endoscopy capsule, this paper presents a new near-lossless image compression algorithm based on the Bayer format image suitable for hardware design. This algorithm can provide low average compression rate ( bits/pixel with high image quality (larger than dB for endoscopic images. Especially, it has low complexity hardware overhead (only two line buffers and supports real-time compressing. In addition, the algorithm can provide lossless compression for the region of interest (ROI and high-quality compression for other regions. The ROI can be selected arbitrarily by varying ROI parameters. In addition, the VLSI architecture of this compression algorithm is also given out. Its hardware design has been implemented in m CMOS process.

  11. Endoscopy in Canada: Proceedings of the National Roundtable

    Directory of Open Access Journals (Sweden)

    Noah Switzer

    2015-01-01

    Full Text Available This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists.

  12. Opinion of gastroenterologists towards quality assurance in endoscopy.

    Science.gov (United States)

    de Jonge, Vincent; Kuipers, Ernst J; van Leerdam, Monique E

    2011-03-01

    Quality assurance has become an important issue. Many societies are adopting quality assurance programs in order to monitor and improve quality of care. To assess the opinion of gastroenterologists towards quality assurance on the endoscopy department. A survey was sent to all gastroenterologists (n=319) in the Netherlands. It assessed their opinion on a quality assurance program for endoscopy units, including its design, logistics, and content. 200 gastroenterologists (63%) completed the questionnaire. 95% had a positive opinion towards quality assurance and 67% supposed an increase in quality. 28% assumed a negative impact on the time available for patient contact by introducing a quality assurance program and 35% that the capacity would decrease. A negative attitude towards disclosure of results to insurance companies (23%) and media (53%) was reported. Female gastroenterologists were less positive to share the results with other stakeholders (pquality measurements were assessment of complications (97%), standardised reporting (96%), and adequate patient information (95%). Gastroenterologists have a positive attitude towards quality assurance. However, concerns do exist about time investment and disclosure of results to others. Information provision and procedure characteristics were considered the most important aspects of quality assurance. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  13. Equilibrium ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lackner, K.S.; Colgate, S.A.; Johnson, N.L.; Kirkpatrick, R.C.; Menikoff, R.; Petschek, A.G.

    1993-01-01

    There are two fundamentally different approaches to igniting DT fuel in an ICF capsule which can be described as equilibrium and hot spot ignition. In both cases, a capsule which can be thought of as a pusher containing the DT fuel is imploded until the fuel reaches ignition conditions. In comparing high-gain ICF targets using cryogenic DT for a pusher with equilibrium ignition targets using high-Z pushers which contain the radiation. The authors point to the intrinsic advantages of the latter. Equilibrium or volume ignition sacrifices high gain for lower losses, lower ignition temperature, lower implosion velocity and lower sensitivity of the more robust capsule to small fluctuations and asymmetries in the drive system. The reduction in gain is about a factor of 2.5, which is small enough to make the more robust equilibrium ignition an attractive alternative

  14. Endurance test for DUPIC capsule

    International Nuclear Information System (INIS)

    Chung, Heung June; Bae, K. K.; Lee, C. Y.; Park, J. M.; Ryu, J. S.

    1999-07-01

    This report presents the pressure drop, vibration and endurance test results for mini-plate fuel rig which were designed fabricately by KAERI. From the pressure drop test results, it is noted that the flow rate across the capsule corresponding to the pressure drop of 200 kPa is measured to be about 9.632 kg/sec. Vibration frequency for the capsule ranges from 14 to 18.5 Hz. RMS (Root Mean Square) displacement for the fuel rig is less than 14 μm, and the maximum displacement is less than 54 μm. Based on the endurance test results, the appreciable fretting wear for the DUPIC capsule was not detected. Oxidation on the support tube is observed, also tiny trace of wear between contact points observed. (author). 4 refs., 10 tabs., 45 figs

  15. Jaw Dislocation as an Unusual Complication of Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Evan S. Dellon

    2016-05-01

    Full Text Available This case report presents an unusual complication of upper endoscopy, resulting in jaw dislocation. Temporomandibular joint dislocation is commonly reported in association with anesthesia and intubation, but it is not widely recognized as a complication of gastrointestinal endoscopy. This report also reviews the current literature regarding this complication and discusses the potential causes of dislocation, differential diagnoses for jaw pain following endoscopy, and recommendations for prevention.

  16. Risk factors for nasal bleeding in patients undergoing transnasal gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Mitsuyo Mieda

    2018-05-01

    Full Text Available Transnasal endoscopy is widely used in screening for upper gastrointestinal lesions because of less associated pain. Nasal bleeding is the most severe adverse effect, but specific risk factors have not been identified. The aim of this study is to identify risk factors for nasal bleeding during transnasal endoscopy. Nasal bleeding occurred in 160/3035 (5.3% of patients undergoing transnasal endoscopy as part of health checkups. Patient data were retrospectively evaluated including anthropometric, medical, and life-style parameters with multiple logistic regression analysis. Multiple logistic regression revealed that nasal bleeding was significantly associated with age in decades [odds ratio/10 years 0.78, 95% confidence interval (CI 0.63–0.97, p = 0.027], female gender (2.15, 95% CI 1.48–3.12, p < 0.001, a history of previous upper gastrointestinal endoscopy (0.55, 95% CI 0.36–0.82, p = 0.004, and chronic/allergic rhinitis (0.60, 95% CI 0.36–0.98, p = 0.043. Other factors including the use of antiplatelet and/or anticoagulant drugs were not significantly associated with nasal bleeding. Female and young patients are significantly associated with an increased risk of bleeding from transnasal endoscopy, but antiplatelet and/or anticoagulant medications and a history of chronic/allergic rhinitis may not be associated. Keywords: Transnasal endoscopy, Nasal bleeding, Risk factors

  17. Training in Endoscopy: Endoscopic Ultrasound

    Directory of Open Access Journals (Sweden)

    Chang Min Cho

    2017-07-01

    Full Text Available Endoscopic ultrasound (EUS has been recently established as an indispensable modality for the diagnosis and management of pancreatobiliary and gastrointestinal (GI disorders. EUS proficiency requires both cognitive and technical abilities, including an understanding of the appropriate indications, the performance of appropriate evaluations before and after the procedure, and the management of procedure-related complications. An increasing demand for skills to handle a growing range of interventional EUS procedures and a continual shortage of EUS training programs are two major obstacles for EUS training. Acquiring the skills necessary to comprehend and conduct EUS often requires training beyond the scope of a standard GI fellowship program. In addition to traditional formal EUS training and preceptorships, regular short-term intensive EUS training programs that provide training at various levels may help EUS practitioners improve and maintain EUS-related knowledges and skills. Theoretical knowledge can be acquired from lectures, textbooks, atlases, slides, videotapes, digital video discs, interactive compact discs, and websites. Informal EUS training is generally based on 1- or 2-day intensive seminars, including didactic lectures, skills demonstrated by expert practitioners through live video-streaming of procedures, and hands-on learning using animal or phantom models.

  18. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  19. Usefulness of Double-Balloon Endoscopy in the Postoperative Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    Masaki Endo

    2011-01-01

    Full Text Available Background. The small intestine has been considered to be a highly difficult organ to visualize in imaging examinations due to its anatomical location compared with the stomach and the colon. In recent years, many imaging modalities have become available, such as CT enterography, MR enterography, capsule endoscopy (CE, and double-balloon endoscopy (DBE. Patients and Methods. DBE was performed in the postoperative intestines of 91 patients (128 DBE examinations at Iwate Medical University between 2004 and 2010. There were 61 male and 30 female patients, and their mean age was 69.7 years (range: 30–80 years. Results. A total of 124 DBE examinations were performed with endoscope insertion into the reconstructed intestines. The endoscope reached the blind end in 115 of 124 examinations, (92.7%. There were 17 patients with obscure gastrointestinal bleeding in whom 30 DBE examinations were performed. The bleeding site was identified in 12 patients (70.6%. Nine patients underwent endoscopic treatment. Hemostasis was achieved in all patients. Conclusion. DBE is very useful modality for the assessment and application of endotherapy to areas of the small bowel which have been altered by surgery.

  20. Flexible and transparent gastric battery: energy harvesting from gastric acid for endoscopy application.

    Science.gov (United States)

    Mostafalu, Pooria; Sonkusale, Sameer

    2014-04-15

    In this paper, we present the potential to harvest energy directly from the digestive system for powering a future wireless endoscopy capsule. A microfabricated electrochemical cell on flexible parylene film is proposed as a gastric battery. This electrochemical cell uses gastric juice as a source of unlimited electrolyte. Planar fabricated zinc [Zn] and palladium [Pd] electrodes serve as anode and cathode respectively. Due to planar geometry, no separator is needed. Moreover the annular structure of the electrodes provides lower distance between cathode and anode reducing the internal resistance. Both electrodes are biocompatible and parylene provides flexibility to the system. For a surface area of 15 mm(2), 1.25 mW is generated which is sufficient for most implantable endoscopy applications. Open circuit output voltage of this battery is 0.75 V. Since this gastric battery does not require any external electrolyte, it has low intrinsic weight, and since it is flexible and is made of biocompatible materials, it offers a promising solution for power in implantable applications. © 2013 Published by Elsevier B.V.

  1. Role of endoscopy in gastroesophageal reflux disease

    Directory of Open Access Journals (Sweden)

    Tarun Rai

    2015-01-01

    Full Text Available Gastroesophageal reflux disease is a condition due to reflux of stomach content in the esophagus causing trouble symptoms or complications or both. GERD is a clinical diagnosis and typically presents with a heartburn and/or regurgitation and a positive response to antacid secretory medications. GERD is the leading outpatient diagnosis among all gastrointestinal disorders in the United States. Approximately 40% of population report occasional symptoms of GERD whereas 10-20% of patients will have symptoms at least once in a week. Recent guidelines from gastrointestinal societies such as American College of Gastroenterology, American Society for Gastrointestinal Endoscopy and American College of Physicians have laid out specific indications regarding role of esophagogastroduodenoscopy in GERD. Despite these recommendations, studies have revealed that one-fifth to two-fifth EGDs may not be clinically indicated, especially where open access endoscopy referral system is used. Traditionally, GERD has been thought to be a disease of the western world. Prevalence rates had been estimated to be lower in Asia when compared to that of the Western Countries. Few recent epidemiological studies in India showed the prevalence of reflux disease in India to be between 8-24%, which is comparable to the western world. The use of EGDs becomes more critical for developing countries such as India where prevalence of GERD and BE is comparable to the western countries but have limited resources. In addition to direct cost for an EGD, it burdens economy with indirect costs such as time off from the work, transportation and any procedural complications. Risk stratifying patients with GERD may therefore prevent unnecessary procedures, harms and costs. The aim of this paper is to review the existing evidence on the role of endoscopy in GERD.

  2. Clinical radiology and endoscopy of the colon

    International Nuclear Information System (INIS)

    Reeders, J.W.A.J.; Rosenbusch, G.

    1994-01-01

    Translated from the original 1993 German edition, this comprehensive volume brings together, in a logically integrated, understandable teaching text, expert imaging by radiology, up-to-date ultrasound and MRI; endoscopy, and histology. This text does justice to the importance of the colon. Such integration of disciplines represents the way medicine should be practiced and taught, and this book will be a model for other subjects in gastroenterology and other organ systems in which different complementary diagnostic techniques are used. The illustrations are of high quality, and both the black and white radiographs and the color endoscopy and histology pictures are faithfully reproduced and supported with informative legends. The condensed text, in outline form, is complemented by an abundance of well-conceived, informative, and clear diagrams, tables, and line drawings. Taken together, this format provides rapid access to all the essential facts and appearances of normal and diseased colon for the casual as well as the serious reader. For the teachers and practitioners of gastroenterology or radiology, this book provides a gold mine of facts and ideas. References have been well selected and presented in an appendix. (orig./UHE)

  3. Imaging of High-Z doped, Imploded Capsule Cores

    Science.gov (United States)

    Prisbrey, Shon T.; Edwards, M. John; Suter, Larry J.

    2006-10-01

    The ability to correctly ascertain the shape of imploded fusion capsules is critical to be able to achieve the spherical symmetry needed to maximize the energy yield of proposed fusion experiments for the National Ignition Facility. Implosion of the capsule creates a hot, dense core. The introduction of a high-Z dopant into the gas-filled core of the capsule increases the amount of bremsstrahlung radiation produced in the core and should make the imaging of the imploded core easier. Images of the imploded core can then be analyzed to ascertain the symmetry of the implosion. We calculate that the addition of Ne gas into a deuterium gas core will increase the amount of radiation emission while preserving the surrogacy of the radiation and hydrodynamics in the indirect drive NIF hohlraum in the proposed cryogenic hohlraums. The increased emission will more easily enable measurement of asymmetries and tuning of the implosion.

  4. C5 capsule operation modes analysis

    International Nuclear Information System (INIS)

    Negut, Gh.; Ancuta, Mirela; Stefan, Violeta

    2008-01-01

    This paper is part of the Nuclear Research Institute Program 13 dedicated to 'TRIGA Research Reactor performance enhancing' and its objective is improving the engineering of the structural materials irradiation. The paper raises the knowledge level on C5 capsule irradiation modes and utilizes previous results in order to increase C5 performances. In the paper the irradiation modes to test zirconium yttrium sample are assessed. These tests are proposed by AECL. There are presented the C5 initial conditions and models. Also. there are presented the thermal hydraulic conditions during normal and accidental operation. The results will be used in the C5 safety report. (authors)

  5. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  6. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    2009-01-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  7. The validity of nasal endoscopy in patients with chronic rhinosinusitis

    DEFF Research Database (Denmark)

    Larsen, K. L.; Lange, B.; Darling, P.

    2018-01-01

    Objectives: Nasal endoscopy is a cornerstone in diagnosing sinonasal disease, but different raters might generate different results using the technique. Our study aims to evaluate the agreement between multiple raters to assess the validity of nasal endoscopy. Design/Participants: Three independe...

  8. Validity, Reliability, and Inertia of Four Different Temperature Capsule Systems.

    Science.gov (United States)

    Bongers, Coen C W G; Daanen, Hein A M; Bogerd, Cornelis P; Hopman, Maria T E; Eijsvogels, Thijs M H

    2018-01-01

    Telemetric temperature capsule systems are wireless, relatively noninvasive, and easily applicable in field conditions and have therefore great advantages for monitoring core body temperature. However, the accuracy and responsiveness of available capsule systems have not been compared previously. Therefore, the aim of this study was to examine the validity, reliability, and inertia characteristics of four ingestible temperature capsule systems (i.e., CorTemp, e-Celsius, myTemp, and VitalSense). Ten temperature capsules were examined for each system in a temperature-controlled water bath during three trials. The water bath temperature gradually increased from 33°C to 44°C in trials 1 and 2 to assess the validity and reliability, and from 36°C to 42°C in trial 3 to assess the inertia characteristics of the temperature capsules. A systematic difference between capsule and water bath temperature was found for CorTemp (0.077°C ± 0.040°C), e-Celsius (-0.081°C ± 0.055°C), myTemp (-0.003°C ± 0.006°C), and VitalSense (-0.017°C ± 0.023°C; P 0.05). Comparable inertia characteristics were found for CorTemp (25 ± 4 s), e-Celsius (21 ± 13 s), and myTemp (19 ± 2 s), whereas the VitalSense system responded more slowly (39 ± 6 s) to changes in water bath temperature (P inertia were observed between capsule systems, an excellent validity, test-retest reliability, and inertia was found for each system between 36°C and 44°C after removal of outliers.

  9. Capsule safety analysis of PRTF irradiation facility

    International Nuclear Information System (INIS)

    Suwarto

    2013-01-01

    Power Ramp Test Facility (PRTF) is an irradiation facility used for fuel testing of power reactor. PRTF has a capsule which is a test fuel rod container. During operation, pressurized water of 160 bars flows through in the capsule. Due to the high pressure it should be analyzed the impact of the capsule on reactor core safety. This analysis has purpose to calculate the ability of capsule pressure capacity. The analysis was carried out by calculating pressure capacity. From the calculating results it can be concluded that the capsule with pressure capacity of 438 bars will be safe to prevent the operation pressure of PRTF. (author)

  10. Probing cell internalisation mechanics with polymer capsules.

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Ping, Yuan; Suma, Tomoya; Cavalieri, Francesca; Besford, Quinn A; Chen, George; Braunger, Julia A; Caruso, Frank

    2016-10-06

    We report polymer capsule-based probes for quantifying the pressure exerted by cells during capsule internalisation (P in ). Poly(methacrylic acid) (PMA) capsules with tuneable mechanical properties were fabricated through layer-by-layer assembly. The P in was quantified by correlating the cell-induced deformation with the ex situ osmotically induced deformation of the polymer capsules. Ultimately, we found that human monocyte-derived macrophage THP-1 cells exerted up to approximately 360 kPa on the capsules during internalisation.

  11. Gastric volvulus following diagnostic upper gastrointestinal endoscopy: a rare complication.

    Science.gov (United States)

    Karthikeyan, Vilvapathy Senguttuvan; Sistla, Sarath Chandra; Ram, Duvuru; Rajkumar, Nagarajan

    2014-02-10

    Esophagogastroduodenoscopy (EGD) is a commonly used, safe diagnostic modality for evaluation of epigastric pain and rarely its major complications include perforation, haemorrhage, dysrhythmias and death. Gastric volvulus has been reported to complicate percutaneous endoscopic gastrostomy but its occurrence after diagnostic EGD has not yet been reported in literature. The successful management relies on prompt diagnosis and gastric untwisting, decompression and gastropexy or gastrectomy in full thickness necrosis of the stomach wall. A 38-year-old woman presented with epigastric pain and EGD showed pangastritis. Immediately after EGD she developed increased severity of pain, vomiting and abdominal distension. Emergency laparotomy carried out for peritoneal signs revealed eventration of left hemidiaphragm with the stomach twisted anticlockwise in the longitudinal axis. After gastric decompression and untwisting of volvulus, anterior gastropexy and gastrostomy was carried out. Hence, we report this rare complication of diagnostic endoscopy and review the existing literature on the management.

  12. The Utility of Endoscopic Biopsies in Patients with Normal Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Anouar Teriaky

    2016-01-01

    Full Text Available Background and Aims. Upper endoscopy is a valuable tool in the workup of gastrointestinal (GI complaints. The purpose of this study is to determine cost and yield of taking biopsies in a normal upper GI tract. Methods. This is a retrospective study where all upper GI biopsies were identified between May 2012 and April 2013, at a tertiary care center. Clinical, procedural, and pathology reports were reviewed to identify patient demographics, procedure information, and pathology diagnosis. Results. Biopsies of the upper GI tract were taken in 1297 patients with normal upper endoscopies. In patients with normal upper endoscopy, 22% of esophageal, 44% of gastric, and 12% of duodenal biopsies were abnormal. The most frequent abnormality was reflux esophagitis in 16% of esophageal biopsies, chronic gastritis in 23% of gastric biopsies, and increased intraepithelial lymphocytes in 6% of duodenal biopsies. The additional cost for taking biopsies in a normal upper GI tract for a diagnosis of eosinophilic esophagitis was $2963 Canadian (CAD, H. pylori associated gastritis was $1404 CAD, and celiac disease was $3024 CAD. Conclusions. The yield of biopsy in normal upper endoscopy varied with location, but the additional expense can be costly and should be tailored to appropriate clinical situations.

  13. "Leopard skin sign": the use of narrow-band imaging with magnification endoscopy in celiac disease.

    Science.gov (United States)

    Tchekmedyian, Asadur J; Coronel, Emmanuel; Czul, Frank

    2014-01-01

    Celiac Disease (CD) is an immune reaction to gluten containing foods such as rye, wheat and barley. This condition affects individuals with a genetic predisposition; it targets the small bowel and may cause symptoms including diarrhea, malabsorption, weight loss, abdominal pain and bloating. The diagnosis is made by serologic testing of celiac-specific antibodies and confirmed by histology. Certain endoscopic characteristics, such as scalloping, reduction in the number of folds, mosaic-pattern mucosa or nodular mucosa, are suggestive of CD and can be visualized under white light endoscopy. Due to its low sensitivity, endoscopy alone is not recommended to diagnose CD; however, enhanced visual identification of suspected mucosal abnormalities through the use of new technologies, such as narrow band imaging with magnification (NBI-ME), could assist in targeting biopsies and thereby increasing the sensitivity of endoscopy. This is a case series of seven patients with serologic and histologic diagnoses of CD who underwent upper endoscopies with NBI-ME imaging technology as part of their CD evaluation. By employing this imaging technology, we could identify patchy atrophy sites in a mosaic pattern, with flattened villi and alteration of the central capillaries of the duodenal mucosa. We refer to this epithelial pattern as "Leopard Skin Sign". Since epithelial lesions are easily seen using NBI-ME, we found it beneficial for identifying and targeting biopsy sites. Larger prospective studies are warranted to confirm our findings.

  14. Autofluorescence endoscopy: feasibility of detection of GI neoplasms unapparent to white light endoscopy with an evolving technology

    NARCIS (Netherlands)

    Haringsma, J.; Tytgat, G. N.; Yano, H.; Iishi, H.; Tatsuta, M.; Ogihara, T.; Watanabe, H.; Sato, N.; Marcon, N.; Wilson, B. C.; Cline, R. W.

    2001-01-01

    Case studies are presented of fluorescence endoscopy in the upper and lower GI tract to illustrate the ability to detect early-stage lesions that were not observable with white light endoscopy or those in which the assessment of the stage or extension of the lesion were equivocal. A new fluorescence

  15. Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

    International Nuclear Information System (INIS)

    Wang, Wen-Hung; Lin, Yen-Chun; Chen, Wen-Cheng; Chen, Miao-Fen; Chen, Chih-Cheng; Lee, Kam-Fai

    2012-01-01

    Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

  16. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    Science.gov (United States)

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. The colon. Clinical radiology and endoscopy

    International Nuclear Information System (INIS)

    Rosenbusch, G.; Reeders, J.W.A.J.

    1993-01-01

    This comprehensive reference work presents in-depth information on the diagnostic radiology and endoscopy of the colon. After a brief review of the history of colon examinations, two chapters explain the anatomy, physiology and pharmacology of the large intestine as well as the methods and techniques applied for radiological examination of the colon. The pathology and characteristical findings and the diagnostic evaluation of the various types of disease are the main subject, with the chapters discussing inflammations and tumors consuming by far most of the space, but there is also valuable information on vascular lesions, traumata, latrogenous or post-surgery lesions, among others, and on the characteristical findings in children. Numerous tables, radiographs and endoscopic images together with drawings illustrate and accompany the textbook information. (orig.). 492 figs., 95 tabs [de

  18. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  19. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  20. Endoscopic non-technical skills team training: the next step in quality assurance of endoscopy training.

    Science.gov (United States)

    Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan

    2014-12-14

    To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day's training utilising real clinical examples. Pre and post-course evaluation comprised participants' patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams' knowledge and safety attitudes.

  1. Endoscopic non-technical skills team training: The next step in quality assurance of endoscopy training

    Science.gov (United States)

    Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan

    2014-01-01

    AIM: To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. METHODS: A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day’s training utilising real clinical examples. Pre and post-course evaluation comprised participants’ patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. RESULTS: Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. CONCLUSION: A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams’ knowledge and safety attitudes. PMID:25516665

  2. Expanding Role of Third Space Endoscopy in the Management of Esophageal Diseases.

    Science.gov (United States)

    Yang, Dennis; Draganov, Peter V

    2018-03-01

    OPINION STATEMENT: "Third space" endoscopy, also commonly referred as submucosal endoscopy, is founded on the principle that the deeper layers of the gastrointestinal (GI) tract can be accessed by tunneling in the submucosal space without compromising the integrity of the overlying mucosa. Peroral endoscopic myotomy (POEM), endoscopic submucosal dissection (ESD), and submucosal tunneling endoscopic resection (STER) are innovative techniques within the field of third space endoscopy in the management of esophageal disorders. POEM has become an accepted minimally invasive therapy for achalasia and related motility disorders with excellent short-term results, with early studies yielding similar efficacy to surgical myotomy and increased durability when compared to pneumatic balloon dilation (PBD). Data are needed to establish long-term outcomes with POEM, with particular interest on the incidence of gastroesophageal reflux, which appears to be higher than initially anticipated. ESD, a mature endoscopic resection technique in Asia, has recently gained traction in the West as a viable option for the management of early Barrett's esophagus (BE) neoplasia. Compared to standard endoscopic mucosal resection (EMR), ESD allows the en bloc resection of lesions irrespective of size, which may facilitate histological interpretation and reduce recurrence rates. Large prospective randomized controlled trials are needed to validate the efficacy and safety of this technique and to further define its role in the endoscopic armamentarium in early BE neoplasia. STER is an attractive technique that theoretically permits the resection of subepithelial esophageal tumors (SETs) arising from the deeper GI layers. Initial studies from highly experienced endoscopic centers support its technical feasibility and safety, although these results should be interpreted with caution due to variability arising from small numbers and heterogeneity among studies. Overall, third space endoscopy is an

  3. Efficacy and safety of flumazenil injection for the reversal of midazolam sedation after elective outpatient endoscopy.

    Science.gov (United States)

    Lee, Sang Pyo; Sung, In-Kyung; Kim, Jeong Hwan; Lee, Sun-Young; Park, Hyung Seok; Shim, Chan Sup

    2018-02-01

    Midazolam sedation during elective endoscopy is widely performed and flumazenil is frequently administered after endoscopy to reverse sedation in clinical practice. This study aimed to investigate the safety and efficacy of flumazenil injections after elective endoscopy under midazolam sedation. Participants who underwent an upper endoscopy under midazolam sedation were randomly divided into two groups. In group I, flumazenil was administered i.v. 10 min after the patient's transfer to the recovery room, and no antidote was injected in group II. The time of stay in the recovery room and adverse events were reviewed through the nursing records. We asked the patients about their pain and degree of satisfaction according to a visual analogue scale (VAS), their memory of the procedure, mental status and the presence of uncomfortable symptoms on the day of the procedure and the day afterwards. The length of stay in recovery was significantly shorter in group I than in group II. No significant differences were found in the number of patients with pain (VAS ≥1), adverse events and discomfort between the two groups. Additionally, there were no differences in the patients' memory of the procedure, satisfaction with sedation, willingness to repeat the endoscopy and mental status. The time in the recovery room after flumazenil administration was significantly shortened, and the use of the drug did not increase the risk of adverse events or discomfort. The use of flumazenil for reversing midazolam sedation seems to be safe and effective. © 2018 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  4. Diagnostic Yield of Microscopic Colitis in Open Access Endoscopy Center.

    Science.gov (United States)

    Ellingson, Derek; Miick, Ronald; Chang, Faye; Hillard, Robert; Choudhary, Abhishek; Ashraf, Imran; Bechtold, Matthew; Diaz-Arias, Alberto

    2011-08-01

    The diagnostic yield in open access endoscopy has been evaluated which generally support the effectiveness and efficiency of open access endoscopy. With a few exceptions, diagnostic yield studies have not been performed in open access endoscopy for more specific conditions. Therefore, we conducted a study to determine the efficiency of open access endoscopy in the detection of microscopic colitis as compared to traditional referral via a gastroenterologist. A retrospective search of the pathology database at the University of Missouri for specimens from a local open access endoscopy center was conducted via SNOMED code using the terms: "microscopic", "lymphocytic", "collagenous", "spirochetosis", "focal active colitis", "melanosis coli" and "histopathologic" in the diagnosis line for the time period between January 1, 2004 and May 25, 2006. Specimens and colonoscopy reports were reviewed by a single pathologist. Of 266 consecutive patients with chronic diarrhea and normal colonoscopies, the number of patients with microscopic disease are as follows: Lymphocytic colitis (n = 12, 4.5%), collagenous colitis (n = 17, 6.4%), focal active colitis (n = 15, 5.6%), and spirochetosis (n = 2, 0.4%). The diagnostic yield of microscopic colitis in this study of an open access endoscopy center does not differ significantly from that seen in major medical centers. In terms of diagnostic yield, open access endoscopy appears to be as effective in diagnosing microscopic colitis.

  5. Capsule performance optimization in the national ignition campaign

    International Nuclear Information System (INIS)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  6. Capsule performance optimization in the National Ignition Campaigna)

    Science.gov (United States)

    Landen, O. L.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Kyrala, G. A.; Michel, P.; Milovich, J.; Munro, D. H.; Nikroo, A.; Olson, R. E.; Robey, H. F.; Spears, B. K.; Thomas, C. A.; Weber, S. V.; Wilson, D. C.; Marinak, M. M.; Suter, L. J.; Hammel, B. A.; Meyerhofer, D. D.; Atherton, J.; Edwards, J.; Haan, S. W.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.

    2010-05-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  7. Capsule performance optimization in the national ignition campaign

    Science.gov (United States)

    Landen, O. L.; MacGowan, B. J.; Haan, S. W.; Edwards, J.

    2010-08-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  8. Capsule performance optimization in the National Ignition Campaign

    International Nuclear Information System (INIS)

    Landen, O. L.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Michel, P.; Milovich, J.; Munro, D. H.; Robey, H. F.; Spears, B. K.; Thomas, C. A.

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  9. Capsule Performance Optimization in the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2009-10-13

    A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  10. Sedation and Monitoring in the Pediatric Patient during Gastrointestinal Endoscopy.

    Science.gov (United States)

    Chung, Hyun Kee; Lightdale, Jenifer R

    2016-07-01

    Sedation is a fundamental component of pediatric gastrointestinal procedures. The 2 main types of sedation for pediatric endoscopy remain general anesthesia and procedural sedation. Although anesthesiologist-administered sedation protocols are more common, there is no ideal regimen for endoscopy in children. This article discusses specific levels of sedation for endoscopy as well as various regimens that can be used to achieve each. Risks and considerations that may be specific to performing gastrointestinal procedures in children are reviewed. Finally, potential future directions for sedation and monitoring that may change the practice of pediatric gastroenterology and ultimately patient outcomes are examined. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Non-anesthesiologist administration of propofol for gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Riphaus, Andrea; Schreiber, Florian

    2015-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA). It addresses the administration of propofol by non-anesthesiologists for gastrointestinal (GI) endoscopy...... driving, drinking alcohol, operating heavy machinery, or engaging in legally binding decisions. Advice should be provided verbally and in written form to the patient, including a 24-hour contact phone number (strong recommendation, low quality evidence). 10 For patients of ASA classes 1 - 2 who have...

  12. Potassium iodide capsule treatment of feline sporotrichosis.

    Science.gov (United States)

    Reis, Erica G; Gremião, Isabella D F; Kitada, Amanda A B; Rocha, Raphael F D B; Castro, Verônica S P; Barros, Mônica B L; Menezes, Rodrigo C; Pereira, Sandro A; Schubach, Tânia M P

    2012-06-01

    Sporotrichosis is a mycosis caused by Sporothrix schenckii. The most affected animal is the cat; it has played an important role in the zoonotic transmission of this disease, especially in Rio de Janeiro, Brazil, since 1998. In order to evaluate the treatment of feline sporotrichosis with potassium iodide, an observational cohort was conducted in 48 cats with sporotrichosis at Instituto de Pesquisa Clínica Evandro Chagas, Fiocruz. All cats received potassium iodide capsules, 2.5 mg/kg to 20 mg/kg q24h. The cure rate was 47.9%, treatment failure was 37.5%, treatment abandonment was 10.4% and death was 4.2%. Clinical adverse effects were observed in 52.1% of the cases. Thirteen cats had a mild increase in hepatic transaminase levels during the treatment, six of them presented clinical signs suggestive of hepatotoxicity. Compared to previous studies with itraconazole and iodide in saturated solution, potassium iodide capsules are an alternative for feline sporotrichosis treatment.

  13. Effect of preparation conditions on properties and permeability of chitosan-sodium hexametaphosphate capsules.

    Science.gov (United States)

    Angelova, N; Hunkeler, D

    2001-01-01

    Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.

  14. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.

    Science.gov (United States)

    Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.

  15. Status of the material capsule irradiation and the development of the new capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Kang, Young-Hwan; Choi, Myoung-Hwan; Cho, Man-Soon; Kim, Bong-Goo

    2006-01-01

    A material capsule system including a main capsule, fixing, control, cutting, and transport systems was developed for an irradiation test of non-fissile materials in HANARO. 14 irradiation capsules (12 instrumented and 2 non-instrumented capsules) have been designed, fabricated and successfully irradiated in the HANARO CT and IR test holes since 1995. The capsules were mainly designed for an irradiation of the RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 5 capsules were made as a part of national projects for the promotion of the HANARO utilization for universities. Based on the accumulated irradiation experience and the user's sophisticated requirements, development of new instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen irrespective of the reactor operation has been performed in HANARO. (author)

  16. The effects of convergence ratio on the implosion behavior of DT layered inertial confinement fusion capsules

    Science.gov (United States)

    Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.

    2017-07-01

    The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).

  17. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  18. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    Haney, T.A.; Wedeking, P.W.; Morcos, N.A.

    1981-01-01

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  19. A cerebrovascular stroke following endoscopy for an elderly patient ...

    African Journals Online (AJOL)

    Ahmed Gado

    2015-02-02

    Feb 2, 2015 ... gastrointestinal bleeding. Not only in upper gastrointestinal bleeding is advanced age a risk of ... plaining of hematemesis of large amount of coffee ground blood. ..... Green J. Complications of gastrointestinal endoscopy. BSG.

  20. Role of endoscopy in evaluating upper gastrointestinal tract lesions in rural population

    Directory of Open Access Journals (Sweden)

    Sharanabasavaraj Javali

    2015-01-01

    males. The incidence of diseases was highest among the elderly age group. Most of the benign mucosal lesions were mainly due to spicy food and habit of tobacco consumption. The incidence of malignancy was mostly among older age group above 50 years. The incidence of the normal study was high owing to increased medical care, easy availability of the procedure and increased medical awareness among patients. In all these cases, upper GI endoscopy not only helped in diagnosing the disease but also helped to get information about pathology, extent of disease and complications that have occurred. This study highlights the importance of diagnostic and therapeutic uses, recording of the various gastroenterological diseases we come across in rural population.

  1. Transcervical heller myotomy using flexible endoscopy.

    Science.gov (United States)

    Spaun, Georg O; Dunst, Christy M; Arnold, Brittany N; Martinec, Danny V; Cassera, Maria A; Swanström, Lee L

    2010-12-01

    Esophageal achalasia is most commonly treated by laparoscopic myotomy. Transesophageal approaches using flexible endoscopy have recently been described. We hypothesized that using techniques and flexible instruments from our NOTES experience through a small cervical incision would be a safer and less traumatic route for esophageal myotomy. The purpose of this study was to evaluate the feasibility, safety, and success rate of using flexible endoscopes to perform anterior or posterior Heller myotomy via a transcervical approach. This animal (porcine) and human cadaver study was conducted at the Legacy Research and Technology Center. Mediastinal operations on ten live, anesthetized pigs and two human cadavers were performed using standard flexible endoscopes through a small incision at the supra-sternal notch. The esophagus was dissected to the phreno-esophageal junction using balloon dilatation in the peri-esophageal space followed by either anterior or posterior distal esophageal myotomy. Success rate was recorded of esophageal dissection to the diaphragm and proximal stomach, anterior and posterior myotomy, perforation, and complication rates. Dissection of the esophagus to the diaphragm and performing esophageal myotomy was achieved in 100% of attempts. Posterior Heller myotomy was always extendable onto the gastric wall, while anterior gastric extension of the myotomy was found to be more difficult (4/4 and 2/8, respectively; P = 0.061). Heller myotomy through a small cervical incision using flexible endoscopes is feasible. A complete Heller myotomy was performed with a higher success rate posteriorly possibly due to less anatomic interference.

  2. Nurse-administered propofol sedation for endoscopy

    DEFF Research Database (Denmark)

    Jensen, J T; Vilmann, P; Horsted, T

    2011-01-01

    BACKGROUND AND STUDY AIMS: The aim of the present study was to perform a risk analysis during the implementation phase of nurse-administered propofol sedation (NAPS) and to validate our structured training program. PATIENTS AND METHODS: A structured training program was developed both for endosco......BACKGROUND AND STUDY AIMS: The aim of the present study was to perform a risk analysis during the implementation phase of nurse-administered propofol sedation (NAPS) and to validate our structured training program. PATIENTS AND METHODS: A structured training program was developed both...... pressure was recorded in 451 patients (26%). Independent risk factors were type of intervention and level of experience of the staff performing the sedation. CONCLUSION: These results were obtained after development of a structured training program both for endoscopists and nurses using propofol...... for sedation, and can be used as basis for further comparison. NAPS for endoscopic procedures is safe when performed by personnel properly trained in airway handling and sedation with propofol, and has considerable advantages compared with conventional sedation for endoscopy....

  3. Sedation-related complications in gastrointestinal endoscopy.

    Science.gov (United States)

    Amornyotin, Somchai

    2013-11-16

    Sedation practices for gastrointestinal endoscopic (GIE) procedures vary widely in different countries depending on health system regulations and local circumstances. The goal of procedural sedation is the safe and effective control of pain and anxiety, as well as to provide an appropriate degree of memory loss or decreased awareness. Sedation-related complications in gastrointestinal endoscopy, once occurred, can lead to significant morbidity and occasional mortality in patients. The risk factors of these complications include the type, dose and mode of administration of sedative agents, as well as the patient's age and underlying medical diseases. Complications attributed to moderate and deep sedation levels are more often associated with cardiovascular and respiratory systems. However, sedation-related complications during GIE procedures are commonly transient and of a mild degree. The risk for these complications while providing any level of sedation is greatest when caring for patients already medically compromised. Significant unwanted complications can generally be prevented by careful pre-procedure assessment and preparation, appropriate monitoring and support, as well as post-procedure management. Additionally, physicians must be prepared to manage these complications. This article will review sedation-related complications during moderate and deep sedation for GIE procedures and also address their appropriate management.

  4. Sedation and monitoring for gastrointestinal endoscopy.

    Science.gov (United States)

    Amornyotin, Somchai

    2013-02-16

    The safe sedation of patients for diagnostic or therapeutic procedures requires a combination of properly trained physicians and suitable facilities. Additionally, appropriate selection and preparation of patients, suitable sedative technique, application of drugs, adequate monitoring, and proper recovery of patients is essential. The goal of procedural sedation is the safe and effective control of pain and anxiety as well as to provide an appropriate degree of memory loss or decreased awareness. Sedation practices for gastrointestinal endoscopy (GIE) vary widely. The majority of GIE patients are ambulatory cases. Most of this procedure requires a short time. So, short acting, rapid onset drugs with little adverse effects and improved safety profiles are commonly used. The present review focuses on commonly used regimens and monitoring practices in GIE sedation. This article is to discuss the decision making process used to determine appropriate pre-sedation assessment, monitoring, drug selection, dose of sedative agents, sedation endpoint and post-sedation care. It also reviews the current status of sedation and monitoring for GIE procedures in Thailand.

  5. Vibration measurements by pulsed digital holographic endoscopy

    Science.gov (United States)

    Schedin, Staffan; Pedrini, Giancarlo; Perez-Lopez, Carlos; Mendoza Santoyo, Fernando

    2005-02-01

    Digital holographic interferometry in combination with a flexible fiber endoscope allows high precision measurements of deformations on hidden objects surfaces, inside cavities and objects with small access apertures. A digital holographic endoscopy system is described with a frequency-doubled, twin oscillator Q-switched pulsed Nd:YAG laser as light source. A sequence of digital hologram pairs are recorded with a maximum repetition rate of 260 ms. Each digital hologram is captured at separate video frames of a CCD-camera. The time separation between the laser pulses from each cavity can be set in the range from 50 to 500 μs. The digital holograms are transferred to a PC via a frame grabber and evaluated quantitatively by the Fourier transform method. The resulting phase fringe pattern has the information needed to evaluate quantitatively the amount of the deformation. Experimental results of vibration measurements of hidden mechanical and biological object surfaces are presented. The quality of the results obtained by mechanical object surfaces is usually higher than for biological surfaces. This can be explained easily by the fact that a biological surface is much more complex than a mechanical surface in the sense that some parts of the surface may reflect the light well whereas other parts may absorb the light. Also, biological surfaces are translucent, which means that part of the light may enter inside the sample where it may be absorbed or reflected.

  6. Ignition capsules with aerogel-supported liquid DT fuel for the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Ho D.D.-M.

    2013-11-01

    Full Text Available For high repetition-rate fusion power plant applications, capsules with aerogel-supported liquid DT fuel can have much reduced fill time compared to β-layering a solid DT fuel layer. The melting point of liquid DT can be lowered once liquid DT is embedded in an aerogel matrix, and the DT vapor density is consequently closer to the desired density for optimal capsule design requirement. We present design for NIF-scale aerogel-filled capsules based on 1-D and 2-D simulations. An optimal configuration is obtained when the outer radius is increased until the clean fuel fraction is within 65 – 75% at peak velocity. A scan (in ablator and fuel thickness parameter space is used to optimize the capsule configurations. The optimized aerogel-filled capsule has good low-mode robustness and acceptable high-mode mix.

  7. U-turn type continuous irradiation method and device for radiation-irradiated capsule

    International Nuclear Information System (INIS)

    Kikuchi, Takayuki.

    1997-01-01

    A capsule to be irradiated is moved while being rotated in one of conveying shafts disposed in a reactor to conduct irradiation treatment. Then, the irradiated capsule is made U-turn in the reactor, inserted to the other conveying shaft and moved while being rotated to conduct irradiation treatment again, and then transported out of the reactor. The device comprises a rotational conveying shaft for moving the irradiated capsule while rotating it, a conveying gear for U-turning the irradiated capsule in the reactor and inserting it to the conveying shaft and a driving mechanism for synchronously rotating the conveying gear relative to the conveying shaft at a constant ratio. Mechanical time loss and manual operation time loss can be reduced upon loading and taking up of the irradiated capsule. Then, the amount of irradiation treatment per unit time is increased, and an optional neutron irradiation amount can be obtained thereby enabling to reduce operator's radiation exposure. (N.H.)

  8. Use of atomic force microscopy and transmission electron microscopy for correlative studies of bacterial capsules.

    Science.gov (United States)

    Stukalov, Oleg; Korenevsky, Anton; Beveridge, Terry J; Dutcher, John R

    2008-09-01

    Bacteria can possess an outermost assembly of polysaccharide molecules, a capsule, which is attached to their cell wall. We have used two complementary, high-resolution microscopy techniques, atomic force microscopy (AFM) and transmission electron microscopy (TEM), to study bacterial capsules of four different gram-negative bacterial strains: Escherichia coli K30, Pseudomonas aeruginosa FRD1, Shewanella oneidensis MR-4, and Geobacter sulfurreducens PCA. TEM analysis of bacterial cells using different preparative techniques (whole-cell mounts, conventional embeddings, and freeze-substitution) revealed capsules for some but not all of the strains. In contrast, the use of AFM allowed the unambiguous identification of the presence of capsules on all strains used in the present study, including those that were shown by TEM to be not encapsulated. In addition, the use of AFM phase imaging allowed the visualization of the bacterial cell within the capsule, with a depth sensitivity that decreased with increasing tapping frequency.

  9. Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.

    Science.gov (United States)

    Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane

    2015-02-15

    Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Remote transmission of live endoscopy over the Internet: Report from the 87th Congress of the Japan Gastroenterological Endoscopy Society.

    Science.gov (United States)

    Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao

    2016-01-01

    Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  11. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    Science.gov (United States)

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    . The new capsule polymerase family described here vastly increases the toolbox of enzymes available for biotechnology purposes. Representatives are abundantly found in human pathogens but also in animal pathogens, paving the way for the exploitation of polymerases for the development of a new generation of vaccines for animal husbandry. Copyright © 2018 Litschko et al.

  12. Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure

    Science.gov (United States)

    Pan, C.; Huang, S.; Chang, Y.; Wen, J.

    2013-12-01

    The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.

  13. Effects of lipophilic components on the compatibility of lipid-based formulations with hard gelatin capsules.

    Science.gov (United States)

    Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S

    2010-01-01

    The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of

  14. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....... chorionic gonadotropin. Oocytes were collected by ultrasonically guided transvaginal aspiration, and spermatozoa were prepared by swim-up technique. The gametes were placed in agar capsules 4 hr after oocyte collection, and the capsules were introduced to the uterine fundus using an insertion tube...

  15. Clinicoepidemiologic characterization and endoscopy in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Hano Garcia, Olga Marina; Wood Rodriguez, Lisette; Villa Jimenez, Oscar Manuel

    2010-01-01

    Colorectal carcinoma is recognized as the second death cause from cancer in most of developed countries; the increasing exposure to risk factor such as smoking, changes in diet, in lifestyles, as well as environmental and infectious factors is conductive to its morbidity and mortality increase. A prospective and descriptive study was conducted in 65 patients older than 18 years seen from April, 2007 to April, 2008 in the Endoscopy Service of the National Institute of Gastroenterology, diagnosed with colorectal carcinoma by colonoscopy and histology. In collection form were registered: sex, age, personal backgrounds of colon cancer, polyps, intestinal inflammatory disease and cholecystectomy; family backgrounds of colon cancer or another location; toxic habits: smoking and alcoholism; diet as regards: vegetal fiber ingestion and animal fat; anatomic location of cancer and histology. We conclude that there was predominance of female sex, the more frequent diagnosis age was between 60 and 70 years. The personal background of colon polyp and the family background of colon cancer were the more frequent. There was also predominance of smokers and heavy drinkers with or without effect. There was a great ingestion of animal fat and few ingestion of vegetal fiber. The more frequent anatomical location was the rectosygmoid, where the histological colon adenocarcinoma had the greater frequency

  16. Development of target capsules for muon catalyzed fusion experiments

    International Nuclear Information System (INIS)

    Watts, K.D.; Jones, S.E.; Caffrey, A.J.

    1983-01-01

    A series of Muon Catalyzed Fusion experiments has been conducted at the Los Alamos Meson Physics Facility to determine how many fusion reactions one muon would catalyze under various temperature, pressure, contamination, and tritium concentration conditions. Target capsules to contain deuterium and tritium at elevated temperatures and pressures were engineered for a maximum temperature of 540 K (512 0 F) and a maximum pressure of 103 MPa (15,000 psig). Experimental data collected with these capsules indicated that the number of fusion reactions per muon continued to increase with temperature up to the 540-K design limit. Theory had indicated that the reaction rate should peak at approximately 540 K, but this was not confirmed during the experiments. A second generation of capsules which have a maximum design temperature of 800 K (980 0 F) and a maximum design pressure of 103 MPa (15,000 psig) has now been engineered. These new capsules will be used to further study the muon catalysis rate versus deuterium-tritium mixture temperature

  17. Thin film drainage between pre-inflated capsules or vesicles

    Science.gov (United States)

    Keh, Martin; Walter, Johann; Leal, Gary

    2013-11-01

    Capsules and vesicles are often used as vehicles to carry active ingredients or fragrance in drug delivery and consumer products and oftentimes in these applications the particles may be pre-inflated due to the existence of a small osmotic pressure difference between the interior and exterior fluid. We study the dynamics of thin film drainage between capsules and vesicles in flow as it is crucial to fusion and deposition of the particles and, therefore, the stability and effectiveness of the products. Simulations are conducted using a numerical model coupling the boundary integral method for the motion of the fluids and a finite element method for the membrane mechanics. For low capillary numbers, the drainage behavior of vesicles and capsules are approximately the same, and also similar to that of drops as the flow-independent and uniform tension due to pre-inflation dominates. The tension due to deformation caused by flow will become more important as the strength of the external flow (i.e. the capillary number) increases. In this case, the shapes of the thin film region are fundamentally different for capsules and vesicles, and the drainage behavior in both cases differs from a drop. Funded by P&G.

  18. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab; Kwon, Soon Tae

    2001-01-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  19. Prevalence and risk factors of adhesive capsulitis of the shoulder after breast cancer treatment.

    Science.gov (United States)

    Yang, Seoyon; Park, Dae Hwan; Ahn, Sei Hyun; Kim, Jisun; Lee, Jong Won; Han, Jun Young; Kim, Dong Kyu; Jeon, Jae Yong; Choi, Kyoung Hyo; Kim, Won

    2017-04-01

    The present study investigated the prevalence and risk factors of adhesive capsulitis of the shoulder in breast cancer patients between 13 and 18 months after surgery. This study included 271 women who underwent surgery for breast cancer with a postoperative period of 13-18 months. Current adhesive capsulitis was defined as restriction of external rotation and one or more additional directional restrictions with history of shoulder pain. Cumulative adhesive capsulitis was defined as current adhesive capsulitis or a previous history of adhesive capsulitis after breast cancer surgery. Multivariate logistic regression analysis was performed to examine associations between current or cumulative adhesive capsulitis and potential risk factors. Among the 271 study patients, 28 (10.3%) and 21 (7.7%) had cumulative or current adhesive capsulitis, respectively. The incidences of cumulative and current adhesive capsulitis were higher in those aged 50-59 years (odds ratio [OR], 9.912; 95% confidence interval [CI], 1.790-54.880; and OR, 12.395; 95% CI, 1.187-129.444, respectively) and those who underwent mastectomy (OR, 6.805; 95% CI, 1.800-25.733; and OR, 9.645; 95% CI, 2.075-44.829, respectively) or mastectomy with reconstruction (OR, 13.122; 95% CI, 2.488-69.218; and OR, 20.075; 95% CI, 2.873-140.261, respectively). Adhesive capsulitis of the shoulder is a common problem after breast cancer treatment. An age of 50-59 years and mastectomy are major risk factors for adhesive capsulitis, and breast reconstruction additionally increases the risk. Patients with these risk factors require greater attention for early diagnosis and proper treatment.

  20. Comparison of thyroid uptake of 131I capsule and solution in rabbits and graves disease patients

    International Nuclear Information System (INIS)

    Zhou Xinjian; Li Fang; Lu Jingqiao; Chen Daming; Zhang Ruilin

    2002-01-01

    Objective: To observe the difference between thyroid uptake rates (TUR) of 131 I capsule and solution in rabbits and Graves disease patients. Methods: Part one: 6 rabbits randomized into two groups received capsule or solution of 131 I 7.4 MBq. Then with SPECT scintigraphy 2,4,6 and 24 h thyroid pure counts in percentage of stomach counts (first frame) were determined. Part two: 1) Measured 131 I capsule standard. 2) 104 patients with Graves disease were administered tracing and therapeutic dose of 131 I capsule (capsule group), 118 of 131 I solution (solution group). Compared the tracing and therapeutic 131 I TUR at 24 h. Results: Part one: There were no significant difference at 2,4,6,24 h TUR between capsule and solution group. For 1 case the maximum TUR was at 6 h in capsule group and 2 cases in solution groups. Part two: 1) For the 131 I capsule administered immediately after being dissolved in 30 mL of water, the activity counts measured were higher by (13.8 +- 2.8)% than it was administered directly, t8.97, P 0.05) and in solution group were (71.3 +- 12.3)% and (65.1 +- 13.0)% (t = 3.82, P 131 I capsule standard should be dissolved before being measured. 3) 131 I capsules can be used as a standard formulation for Graves disease patients. 4) The dose of 131 I should be increased as tracer TUR is larger than 80.0%

  1. Influence of different excipients on the properties of hard gelatin capsules with metamizole sodium

    Directory of Open Access Journals (Sweden)

    Rogowska Magdalena

    2016-09-01

    Full Text Available Metamizole is an effective non-opioid analgesic drug used in the treatment of acute and chronic pain. Due to induced potentially life-threatening blood disorders, metamizole was withdrawn from market in many parts of the world, however, it is one of the most popular analgesics in Poland that is available as an over the counter drug. Patients tend to prefer capsules over tablets, as they are easier to swallow and taste better. The powder-filled capsules also have greater bioavailability and require less excipients, as compared to tablets. Polymic excipients are mainly used in capsule filling, and have influence upon the physico-chemical properties of the hard gelatin capsules and the powder formulation. The aim of the study was to determine whether various combinations of polymers impact the disintegration time and pharmaceutical availability of hard gelatin capsules with metamizole sodium. The results of our work demonstrated that the 80% of all active substance was released in all tested formulations within 15 minutes. Herein, the capsule containing lactose monohydrate had the longest release (4% after 2 min., while capsules containing mannitol had the fastest release (81.2% after 2 min.. Moreover, the addition of HPMC to capsules with lactose brought about a slight increase in the metamizole release rate, while the addition of PVP 30 to capsules with microcrystalline cellulose slightly accelerated release. This data suggests that the use of different polymers in capsules formulation brings about changes in the physical properties of powders and modifies the release profile of metamizole. In our study, the most preferred formulation was one containing microcrystalline cellulose (good powder properties and fairly fast release.

  2. Hydrodynamick instabilities on ICF capsules

    International Nuclear Information System (INIS)

    Haan, S.W.

    1991-01-01

    This article summarizes our current understanding of hydrodynamic instabilities as relevant to ICF. First we discuss classical, single mode Rayleigh-Taylor instability, and nonlinear effects in the evolution of a single mode. Then we discuss multimode systems, considering: (1) the onset of nonlinearity; (2) a second order mode coupling theory for weakly nonlinear effects, and (3) the fully nonlinear regime. Two stabilization mechanisms relevant to ICF are described next: gradient scale length and convective stabilization. Then we describe a model which is meant to estimate the weakly nonlinear evolution of multi-mode systems as relevant to ICF, given the short-wavelength stabilization. Finally, we discuss the relevant code simulation capability, and experiments. At this time we are quite optimistic about our ability to estimate instability growth on ICF capsules, but further experiments and simulations are needed to verify the modeling. 52 refs

  3. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    Science.gov (United States)

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Significantly reduced hypoxemic events in morbidly obese patients undergoing gastrointestinal endoscopy: Predictors and practice effect

    Directory of Open Access Journals (Sweden)

    Basavana Gouda Goudra

    2014-01-01

    Full Text Available Background: Providing anesthesia for gastrointestinal (GI endoscopy procedures in morbidly obese patients is a challenge for a variety of reasons. The negative impact of obesity on the respiratory system combined with a need to share the upper airway and necessity to preserve the spontaneous ventilation, together add to difficulties. Materials and Methods: This retrospective cohort study included patients with a body mass index (BMI >40 kg/m 2 that underwent out-patient GI endoscopy between September 2010 and February 2011. Patient data was analyzed for procedure, airway management technique as well as hypoxemic and cardiovascular events. Results: A total of 119 patients met the inclusion criteria. Our innovative airway management technique resulted in a lower rate of intraoperative hypoxemic events compared with any published data available. Frequency of desaturation episodes showed statistically significant relation to previous history of obstructive sleep apnea (OSA. These desaturation episodes were found to be statistically independent of increasing BMI of patients. Conclusion: Pre-operative history of OSA irrespective of associated BMI values can be potentially used as a predictor of intra-procedural desaturation. With suitable modification of anesthesia technique, it is possible to reduce the incidence of adverse respiratory events in morbidly obese patients undergoing GI endoscopy procedures, thereby avoiding the need for endotracheal intubation.

  5. Significantly reduced hypoxemic events in morbidly obese patients undergoing gastrointestinal endoscopy: Predictors and practice effect.

    Science.gov (United States)

    Goudra, Basavana Gouda; Singh, Preet Mohinder; Penugonda, Lakshmi C; Speck, Rebecca M; Sinha, Ashish C

    2014-01-01

    Providing anesthesia for gastrointestinal (GI) endoscopy procedures in morbidly obese patients is a challenge for a variety of reasons. The negative impact of obesity on the respiratory system combined with a need to share the upper airway and necessity to preserve the spontaneous ventilation, together add to difficulties. This retrospective cohort study included patients with a body mass index (BMI) >40 kg/m(2) that underwent out-patient GI endoscopy between September 2010 and February 2011. Patient data was analyzed for procedure, airway management technique as well as hypoxemic and cardiovascular events. A total of 119 patients met the inclusion criteria. Our innovative airway management technique resulted in a lower rate of intraoperative hypoxemic events compared with any published data available. Frequency of desaturation episodes showed statistically significant relation to previous history of obstructive sleep apnea (OSA). These desaturation episodes were found to be statistically independent of increasing BMI of patients. Pre-operative history of OSA irrespective of associated BMI values can be potentially used as a predictor of intra-procedural desaturation. With suitable modification of anesthesia technique, it is possible to reduce the incidence of adverse respiratory events in morbidly obese patients undergoing GI endoscopy procedures, thereby avoiding the need for endotracheal intubation.

  6. Fifteen-Year-Old Male with Type 2 Autoimmune Pancreatitis: An Argument for Endoscopy

    Directory of Open Access Journals (Sweden)

    Nathan T. Kolasinski

    2017-05-01

    Full Text Available Type 2 autoimmune pancreatitis, an increasingly recognized etiology of pancreatitis in patients less than 20 years old, has characteristically been diagnosed with the histological finding of duct-centric pancreatitis in a patient who lacks elevated serum immunoglobulin G4. We present the case of a nonobese 15-year-old male, without any chronic medical conditions, who presented with the chief complaint of abdominal pain. The laboratory study results were remarkable for a lipase level of 5,419 U/L and a γ-glutamyl transferase level of 373 U/L. Magnetic resonance cholangiopancreatography revealed delayed contrast enhancement of the pancreas, diffuse parenchymal enlargement, and lack of normal lobulation. The patient’s serum immunoglobulin G4 level was found to be 66 mg/dL, which was within normal limits and supportive of a diagnosis of type 2 autoimmune pancreatitis. Despite the absence of intestinal complaints, the patient underwent subsequent endoscopy due to the correlation of type 2 autoimmune pancreatitis with inflammatory bowel disease that has been described in recent literature. Pan-colonic mild colitis was visualized, and the patient began treatment with steroids, to which he quickly responded. Performing endoscopy on this patient allowed for confident initiation of early therapy for both autoimmune pancreatitis and inflammatory bowel disease, and may have limited further surgical intervention and disease progression. For these reasons, this case highlights the utility of endoscopy in pediatric patients with suspected type 2 autoimmune pancreatitis, even in the absence of intestinal symptoms.

  7. Review of musculoskeletal injuries and prevention in the endoscopy practitioner.

    Science.gov (United States)

    Harvin, Glenn

    2014-08-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces.

  8. Narrow-Band Imaging: Clinical Application in Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Sandra Barbeiro

    2018-03-01

    Full Text Available Narrow-band imaging is an advanced imaging system that applies optic digital methods to enhance endoscopic images and improves visualization of the mucosal surface architecture and microvascular pattern. Narrow-band imaging use has been suggested to be an important adjunctive tool to white-light endoscopy to improve the detection of lesions in the digestive tract. Importantly, it also allows the distinction between benign and malignant lesions, targeting biopsies, prediction of the risk of invasive cancer, delimitation of resection margins, and identification of residual neoplasia in a scar. Thus, in expert hands it is a useful tool that enables the physician to decide on the best treatment (endoscopic or surgical and management. Current evidence suggests that it should be used routinely for patients at increased risk for digestive neoplastic lesions and could become the standard of care in the near future, at least in referral centers. However, adequate training programs to promote the implementation of narrow-band imaging in daily clinical practice are needed. In this review, we summarize the current scientific evidence on the clinical usefulness of narrow-band imaging in the diagnosis and characterization of digestive tract lesions/cancers and describe the available classification systems.

  9. The use of tritium rich capsules with 25-35% deuterium to achieve ignition at the National Ignition Facility

    Science.gov (United States)

    Wilson, D. C.; Spears, B. K.; Hatchett, S. P., Ii; Cerjan, C. J.; Springer, P. T.; Clark, D. S.; Edwards, M. J.; Salmonson, J. D.; Weber, S. V.; Hammel, B. A.; Grim, G. P.; Herrmann, H. W.; Wilke, M. D.

    2010-08-01

    Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >~25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.

  10. The use of tritium rich capsules with 25-35% deuterium to achieve ignition at the National Ignition Facility

    International Nuclear Information System (INIS)

    Wilson, D C; Grim, G P; Herrmann, H W; Wilke, M D; Spears, B K; Ii, S P Hatchett; Cerjan, C J; Springer, P T; Clark, D S; Edwards, M J; Salmonson, J D; Weber, S V; Hammel, B A

    2010-01-01

    Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >∼25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.

  11. The use of tritium rich capsules with 25-35% deuterium to achieve ignition at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D C; Grim, G P; Herrmann, H W; Wilke, M D [Los Alamos National Laboratory, Los Alamos, NM, 87545 (United States); Spears, B K; Ii, S P Hatchett; Cerjan, C J; Springer, P T; Clark, D S; Edwards, M J; Salmonson, J D; Weber, S V; Hammel, B A, E-mail: dcw@lanl.go [Lawrence Livermore National Laboratory, Livermore, CA, 94550 (United States)

    2010-08-01

    Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >{approx}25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.

  12. Ultrathin endoscopy versus high-resolution endoscopy for diagnosing superficial gastric neoplasia.

    Science.gov (United States)

    Toyoizumi, Hirobumi; Kaise, Mitsuru; Arakawa, Hiroshi; Yonezawa, Jin; Yoshida, Yukinaga; Kato, Masayuki; Yoshimura, Noboru; Goda, Ken-ichi; Tajiri, Hisao

    2009-08-01

    Ultrathin endoscopy (UTE) is an acceptable and cost-effective alternative to EGD with the patient under sedation, although the diagnostic accuracy of UTE is not well established. To compare the diagnostic accuracy of UTE and high-resolution endoscopy (HRE) for superficial gastric neoplasia. Prospective comparative study. Academic center. Patients with or without superficial gastric neoplasia underwent peroral UTE and HRE, back-to-back in a random order while under standard sedation. The procedures were performed by 2 endoscopists who were blinded to the clinical information. The rate of missed lesions and misdiagnosis, sensitivity, and specificity for the diagnosis of gastric neoplasia when using pathology as the reference standard. In total, 126 lesions (41 superficial gastric neoplasias, 85 nonneoplastic lesions) were recorded in 57 enrolled patients. For the diagnosis of gastric neoplasia, the sensitivity of UTE (58.5%) was significantly (P = .021) lower than that of HRE (78%), and the specificity of UTE (91.8%) was significantly (P = .014) lower than that of HRE (100%). The rate of missed lesions and misdiagnosis of gastric neoplasias when using UTE (41.5%) was significantly (P > .001) higher than that of HRE (22.0%). The corresponding rate of neoplasias at the proximal portion (fornix and corpus) when using UTE (29%) was significantly (P = .002) higher than that of HRE (7.2%), although the rates of neoplasias at the distal portion (angulus and antrum) were comparable for UTE and HRE. Small sample numbers in an enriched population. The diagnostic accuracy of UTE is significantly lower than that of HRE for superficial gastric neoplasia, and this difference is particularly striking for neoplasias in the proximal stomach. For UTE to be used as an alternative modality, improvements in optical quality and the incorporation of additional procedures, including close-range observations and chromoendoscopy, are required to enhance visualization.

  13. Effects of Tang Mai Kang Capsule on Angioneurotic Lesions in Alloxan-Induced Diabetic Mice

    Institute of Scientific and Technical Information of China (English)

    李华; 王军; 高丽君; 郭永成

    2004-01-01

    The effects of Tang Mai Kang Capsule (糖脉康胶囊) on blood sugar level, gangrene of the tail-tip, pain threshold and learning and memory abilities were investigated in alloxan-induced diabetic mice. The results showed that Tang Mai Kang Capsule could significantly decrease blood sugar level and incidence rate of gangrene of the tail-tip, increase pain threshold, and strengthen learning and memory abilities, suggesting that Tang Mai Kang Capsule functions to decrease blood sugar level and improve the complicated angioneurotic lesions of diabetes.

  14. Simulations of fill tube effects on the implosion of high-foot NIF ignition capsules

    International Nuclear Information System (INIS)

    Dittrich, T R; Hurricane, O A; Berzak-Hopkins, L F; Callahan, D A; Casey, D T; Clark, D; Dewald, E L; Doeppner, T; Haan, S W; Hammel, B A; Harte, J A; Hinkel, D E; Kozioziemski, B J; Kritcher, A L; Ma, T; Nikroo, A; Pak, A E; Parham, T G; Park, H-S; Patel, P K

    2016-01-01

    Encouraging results have been obtained using a strong first shock during the implosion of carbon-based ablator ignition capsules. These “high-foot” implosion results show that capsule performance deviates from 1D expectations as laser power and energy are increased. A possible cause of this deviation is the disruption of the hot spot by jets originating in the capsule fill tube. Nominally, a 10 μm outside diameter glass (SiO 2 ) fill tube is used in these implosions. Simulations indicate that a thin coating of Au on this glass tube may lessen the hotspot disruption. These results and other mitigation strategies will be presented. (paper)

  15. Simulations of fill tube effects on the implosion of high-foot NIF ignition capsules

    Science.gov (United States)

    Dittrich, T. R.; Hurricane, O. A.; Berzak-Hopkins, L. F.; Callahan, D. A.; Casey, D. T.; Clark, D.; Dewald, E. L.; Doeppner, T.; Haan, S. W.; Hammel, B. A.; Harte, J. A.; Hinkel, D. E.; Kozioziemski, B. J.; Kritcher, A. L.; Ma, T.; Nikroo, A.; Pak, A. E.; Parham, T. G.; Park, H.-S.; Patel, P. K.; Remington, B. A.; Salmonson, J. D.; Springer, P. T.; Weber, C. R.; Zimmerman, G. B.; Kline, J. L.

    2016-05-01

    Encouraging results have been obtained using a strong first shock during the implosion of carbon-based ablator ignition capsules. These “high-foot” implosion results show that capsule performance deviates from 1D expectations as laser power and energy are increased. A possible cause of this deviation is the disruption of the hot spot by jets originating in the capsule fill tube. Nominally, a 10 μm outside diameter glass (SiO2) fill tube is used in these implosions. Simulations indicate that a thin coating of Au on this glass tube may lessen the hotspot disruption. These results and other mitigation strategies will be presented.

  16. Videoscopic Heller Myotomy with Intraoperative Endoscopy Promotes Optimal Outcomes

    Science.gov (United States)

    Bloomston, Mark; Brady, Patrick

    2002-01-01

    Background and Objectives: Minimally invasive surgical techniques are applicable to achalasia, but the optimum approach to intraoperative assessment of adequacy of myotomy remains unestablished. We set out to show that videoscopic Heller myotomy with concurrent endoscopy ensures adequacy of myotomy while limiting postoperative clinically apparent reflux. Methods: Seventy-eight consecutive patients with achalasia underwent videoscopic Heller myotomy with concomitant endoscopy between 1992 and 1998. Fundoplication was not routinely undertaken. Results: Preoperative symptoms consisted of dysphagia (100%), emesis/regurgitation (68%), heartburn (58%), and postprandial chest pain (49%). Following myotomy, significant improvement (P Heller myotomy guides the extent and adequacy of myotomy. By utilizing a focused dissection with preservation of the natural antireflux mechanisms around the gastroesophageal junction and limiting the extent of myotomy along the cardia, postoperative reflux symptoms are minimized. We advocate concomitant endoscopy during Heller myotomy to guide myotomy and submit that routine fundoplication is clinically unnecessary. PMID:12113416

  17. [The role of endoscopy in gastroenteropancreatic neuroendocrine tumors].

    Science.gov (United States)

    Magno, L; Sivero, L; Napolitano, V; Ruggiero, S; Fontanarosa, G; Massa, S

    2010-01-01

    Versione italiana Riassunto: Il ruolo dell'endoscopia nei tumori neuroendocrini gastroenteropancreatici. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa I tumori neuroendocrini (NET) gastro-entero-pancreatici (GEP) sono neoplasie rare che originano dalle cellule neuroendocrine del tubo digerente e del pancreas. L'endoscopia digestiva e l'ecoendoscopia rivestono un ruolo importante nella diagnosi, stadiazione e sorveglianza dei pazienti con NET. Inoltre, in casi selezionati, le tecniche endoscopiche operative consentono il trattamento di queste neoplasie in fase precoce. English version Summary: The role of endoscopy in gastroenteropancreatic neuroendocrine tumors. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa Gastroenteropancreatic (GEP) neuroendocrine tumors (NET) are rare neoplasia arisen from neuroendocrine cells present in the gut mucosa and pancreas. Digestive endoscopy and endoscopic ultrasonography play a relevant role in NET diagnosis, stadiation and surveillance. Moreover, in selected patients, surgical endoscopy allows the tratment of these cancers at an early stage.

  18. Cerebral gas embolism due to upper gastrointestinal endoscopy.

    Science.gov (United States)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E

    2009-07-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of oesophageal cancer. During the procedure, cerebral gas emboli developed resulting in an acute left-sided hemiparesis. After hyperbaric oxygen therapy, the patient recovered almost completely. The aetiology and treatment is discussed based on the reviewed literature. Once cerebral gas emboli are recognized, patient outcome can be improved by hyperbaric oxygen therapy.

  19. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    Science.gov (United States)

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  20. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis.

    Science.gov (United States)

    Canaval Zuleta, Héctor Julián; Company Campins, María M; Dolz Abadía, Carlos

    2016-06-01

    Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  1. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis

    Directory of Open Access Journals (Sweden)

    Héctor Julian Canaval-Zuleta

    Full Text Available Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  2. Features of Joint Capsule Formation After Antenatal Action of Antigen

    Directory of Open Access Journals (Sweden)

    A.V. Fedotchenko

    2014-10-01

    Full Text Available In this paper using morphometric, histological, histochemical and statistical methods, we have investigated the dynamics of hip joint capsule formation in white laboratory rats during the postnatal period after intrefetal introduction of antigen. It is found that antenatal effect of antigen leads to an increase in the number of lymphocytes, in particular PNA+, in joint capsule. Against this background, we observed an increase in the proportion of cells, the basic substance and elastic fibers, while reducing the content of collagen fibers, violations in polysaccharides and fibroblasts distribution that indicates the development of dysplastic processes in the hip joint and can be regarded as the leading factor of coxarthrosis development. Experimentally, we have detected arachnodactylia as a visual clinical manifestation of dysplasia.

  3. Consensus guidelines for the use of bowel preparation prior to colonic diagnostic procedures: colonoscopy and small bowel video capsule endoscopy

    NARCIS (Netherlands)

    Mathus-Vliegen, Elisabeth; Pellisé, Maria; Heresbach, Denis; Fischbach, Wolfgang; Dixon, Tricia; Belsey, Jonathan; Parente, Fabrizio; Rio-Tinto, Ricardo; Brown, Alistair; Toth, Ervin; Crosta, Cristiano; Layer, Peter; Epstein, Owen; Boustiere, Christian

    2013-01-01

    Adequate bowel preparation prior to colonic diagnostic procedures is essential to ensure adequate visualisation. This consensus aims to provide guidance as to the appropriate use of bowel preparation for a range of defined clinical circumstances. A consensus group from across Europe was convened and

  4. Capsule production by Pseudomonas aeruginosa

    Energy Technology Data Exchange (ETDEWEB)

    Lynn, A.R.

    1984-01-01

    Mucoid strains of Pseudomonas aeruginosa, associated almost exclusively with chronic respiratory infections in patients with cystic fibrosis, possess a capsule composed of alginic acid similar to one produced by Azotobacter vinelandii. Recent reports have provided evidence that the biosynthetic pathway for alginate in P. aeruginosa may differ from the pathway proposed for A. vinelandii in that synthesis in P. aeruginosa may occur by way of the Entner-Doudoroff pathway. Incorporation of isotope from (6-/sup 14/C)glucose into alginate by both P. aueroginosa and A. vinelandii was 10-fold greater than that from either (1-/sup 14/C)/sup -/ or (2-/sup 14/C)glucose, indicating preferential utilization of the bottom half of the glucose molecule for alginate biosynthesis. These data strongly suggest that the Entner-Doudoroff pathway plays a major role in alginate synthesis in both P. aeruginosa and A. vinelandii. The enzymes of carbohydrate metabolism in mucoid strains of P. aeruginosa appear to be unchanged whether alignate is actively produced or not and activities do not differ significantly from nonmucoid strain PAO.

  5. Vortex rings from Sphagnum moss capsules

    Science.gov (United States)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  6. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  7. Myofibroblast Upregulators are Elevated in Joint Capsules in Posttraumatic Contractures

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; Hart, David A.

    2007-01-01

    We hypothesized specific growth factors are increased in the elbow capsules of patients with post traumatic elbow contractures. A model of surgically induced joint contracture in rabbit knees was developed to study the growth factor expression in joint contractures. This study demonstrates this model mimics the human condition and analyzes how the growth factor levels decrease with time in rabbit knees with contractures. Reverse transcription polymerase chain reaction was used to measure mRNA...

  8. Endoscopy services in KwaZulu-Natal Province, South Africa, are ...

    African Journals Online (AJOL)

    is based on the values and principles of primary healthcare, but major discrepancies ... To audit the GI endoscopy services in KZN and compare these with the current guidelines for ..... Quality assurance of endoscopy units. Best Pract Res Clin ...

  9. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  10. Therapeutic applications of radioactive 131iodine: Procedures and incidents with capsules

    International Nuclear Information System (INIS)

    Al Aamri, Marwa; Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Balushi, Naima

    2016-01-01

    Treatments for thyrotoxicosis and carcinoma thyroid are carried out by oral administration of radioactive iodine ( 131 I) in the form of liquid or capsules. The liquid form of 131 I has higher risk factors such as vapourization, spillage and need for management of higher activity wastes. Use of 131 I in capsule form simplify procedures of handling compared to liquid form of 131 I. The guidelines of safe handling and quality assurance aspects for therapeutic use 131 I are well outlined by International Atomic Energy Agency (IAEA) reports. A few unusual incidents with I-131 capsules encountered in the past need to be highlighted from health physics point of view. In Royal Hospital, Oman, I-131 is imported in capsules, and the total activity handled/year steadily increased over 10 years. Discrete activities range from 185 MBq (5 mCi) up to 7.4 GBq (200 mCi). In four incidents deviations in standard operational procedures were recorded. Nature of incidents is described as follows: (1) After assay of activity, the capsule was directly put in the lead container with missing of inner cap. (2) Patient poured water in the Perspex tube, when the capsule was handed over to her, making an emergency situation. (3) In 3 high activity capsules (2 nos 2.96 GBq, 1 no. 4.26 GBq), observed sticky behavior in capsule holder on the 2 nd day post receipt, which were in order on the 1 st day. (4) A capsule could not be swallowed by a patient, which was taken back from the mouth. Monitoring of patient later did not show residual ingested activity. The report documents some of the unusual incidents for information to other centers engaged in such radioactive administrations

  11. Radioactive gas-containing polymeric capsule

    International Nuclear Information System (INIS)

    Winchell, H.S.; Lewis, R.E.

    1975-01-01

    A disposable ventilation study system for dispensing a single patient dosage of gaseous radioisotopes to patients for pulmonary function studies is disclosed. A gas impermeable capsule encloses the gaseous radioisotope and is stored within a radioactivity shielding body of valve means which shears the capsule to dispense the radioisotope to the patient. A breathing bag receives the patient's exhalation of the radioisotope and permits rebreathing of the radioisotope by the patient. 18 claims, 7 drawing figures

  12. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  13. Endoscopy services in KwaZulu-Natal Province, South Africa, are ...

    African Journals Online (AJOL)

    There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 ...

  14. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate-the learning curve for endoscopy training

    Science.gov (United States)

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-01-01

    BACKGROUND: Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. OBJECTIVE: To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. METHODS: The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists/surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The ‘Endoscopy Task Load Index’ was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. RESULTS: From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. DISCUSSION: The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers. PMID:24619638

  15. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate the learning curve for endoscopy training.

    Science.gov (United States)

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-03-01

    Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists⁄surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The 'Endoscopy Task Load Index' was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers.

  16. Quantitative ENT endoscopy: the future in the new millennium

    Science.gov (United States)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  17. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    International Nuclear Information System (INIS)

    Shigematsu, Y.; Korogi, Y.; Hirai, T.; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-01-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.)

  18. Studying and Incorporating Efficiency into Gastrointestinal Endoscopy Centers

    Directory of Open Access Journals (Sweden)

    Lukejohn W. Day

    2015-01-01

    Full Text Available Efficiency is defined as the use of resources in such a way as to maximize the production of goods and services. Improving efficiency has been the focus of management in many industries; however, it has not been until recently that incorporating efficiency models into healthcare has occurred. In particular, the study and development of improvement projects aimed at enhancing efficiency in GI have been growing rapidly in recent years. This focus on improving efficiency in GI has been spurred by the dramatic rise in the demand for endoscopic procedures as well as the rising number of insured patients requiring GI care coupled at the same time with limited resources in terms of staffing and space in endoscopy centers. This paper will critically review the history of efficiency in endoscopy centers, first by looking at other healthcare industries that have extensively studied and improved efficiency in their fields, examine a number of proposed efficiency metrics and benchmarks in endoscopy centers, and finally discuss opportunities where endoscopy centers could improve their efficiency.

  19. Prevalence of Helicobacter pylori in Northern Jordan: Endoscopy based study

    International Nuclear Information System (INIS)

    Bani-Hani, Kamal E.; Hammouri, Shadi M.

    2001-01-01

    Helicobacter pylori infection is considered the most common infection worldwide and is associated with many other disorders. The aim of this study is to determine the prevalence of this infection among patients undergoing endoscopy in Northern Jordan. Between November 1998 and September 2000, all patients referred from the Gastro-esophageal Clinic to the Endoscopy Unit at Princess Basma Teaching Hospital, Irbid, Northern Jordan were enrolled in this prospective study. For each patient clinical and epidemiological data was collected and endoscopy was performed. At least 3 antral biopsies were obtained from each patient, and these were examined histologically for the presence of gastritis and stained for Helicobacter pylori using modified Giemsa stain. A total of 197 consecutive patients (113 females) with a mean age of 40.2 years (range 15-91 years) were studied. Abdominal pain was the highest presenting symptom. Gastritis 91% and esophagitis 42% were the most frequent endoscopic findings. Gastritis was documented histologically in 183 (93%) of patients. Helicobacter pylori was found in 161 patients (82%), with all of these having histological gastritis. The 11 patients with gastric ulcer, compared to the 51 out of the 59 (86%) patients with duodenal ulcer, showed Helicobacter pylori in their biopsies. The prevalence of Helicobacter pylori infection in patients subjected to an upper gastrointestinal endoscopy in Jordan is high. This study confirms that Helicobacter pylori is significantly associated with gastritis and peptic ulcer. Further studies are needed to determine the types of Helicobacter pylori strains present in Jordan. (author)

  20. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    Energy Technology Data Exchange (ETDEWEB)

    Shigematsu, Y.; Korogi, Y.; Hirai, T. [Kumamoto Univ. (Japan). Dept. of Radiology; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-10-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.) With 6 figs., 16 refs.

  1. Upper gastrointestinal diseases in patients for endoscopy in South ...

    African Journals Online (AJOL)

    The most common endoscopy finding was gastritis (40.2%), followed by normal examination (15.2%), oesophageal cancer (13.6%), gastric ulcer (7.6%) and gastric cancer (7.1%). Patients older than 40 years (n=110) had significant findings including gastritis (50.9%), oesophageal cancer (22.7%) and gastric cancer ...

  2. ALARA implementation in 131I therapeutic capsule production facility

    International Nuclear Information System (INIS)

    Kumawat, Lalit; Swaminathan, N.; Sudheer, T.S.; Sachdev, S.S.; Arora, S.S.; Vairalkar, K.G.

    2005-01-01

    Sodium iodide 131 I solution had been invariably administered to patients for both diagnosis and therapy of thyrotoxicosis. The undue exposure to non-target organs has been over come by introducing NaI ( 131 I) in a gelatin capsule. BRIT has set up experimental facility for the preparation and the production volume has augmented into four fold due to increase in demand and the same facility is being used to cater the need. However, the adequately shielded facility (fume hood) used for (manual) dispensing activity in capsules, capsules and product vial capping, transfer of the vials into lead pots and activity measurement of each vial has resulted in significant increase in the personnel exposure. The sources had been identified and efforts were made to reduce the exposure in these operations. An annular shield was introduced around the dispenser, resulted in the reduction of radiation field at wrist level by a factor of three. Introduction of shielded automated dispenser and usage of longer tools for transfer and capping of vials has effected in two times reduction of collective wrist dose. Currently, the relocated capping station two meters away from the source certainly will bring down further exposure. (author)

  3. Status for development of a capsule and instruments for high-temperature irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Choo, Kee Nam; Lee, Chul Yong; Yang, Seong Woo; Shim, Kyue Taek; Chung, Hwan-Sung [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2012-03-15

    As the reactors planned in the Gen-IV program will be operated at high temperature and under high neutron flux, the requirements for irradiation of materials at high temperature are recently being gradually increased. The irradiation tests of materials in HANARO up to the present have been performed usually at temperatures below 300degC at which the RPV materials of the commercial reactors are being operated. To overcome the restriction for high-temperature use of Al thermal media of the existing standard capsule, a new capsule with double thermal media composed of two kinds of materials such as Al-Ti and Al-graphite was designed and fabricated as a more advanced capsule than the single thermal media capsule. (author)

  4. CT virtual endoscopy: a study of the capability to display the structures and abnormalities in nasal cavity

    International Nuclear Information System (INIS)

    Han Ping; Brambs, H.J.; Sokiranski, R.

    1999-01-01

    Objective: To evaluate display ability of virtual endoscopy and its clinical application in comparison with fiberoptic nasal endoscopy. Methods: 11 patients (22 nasal cavities) were examined by virtual endoscopy after axial spiral CT scanning was performed. Virtual endoscopy was performed by Explorer software package in a computer workstation. 9 patients (18 nasal cavities) underwent fiberoptic endoscopy. Results: Virtual endoscopy could clearly demonstrate the anatomical structures in nasal cavity, septal deviation, nasal meatus narrowing and obstruction, turbinate hyperplasia, and pathological masses larger than 3 mm in diameter. However, 'false adhesions' may appear in virtual endoscopy. The main limitation of virtual endoscopy was inability to evaluate mucosa and lack of histological diagnosis. Conclusions: Virtual endoscopy is a new, non-invasive method for demonstrating anatomical structures and diseases in nasal cavity. Its display ability is comparable with fiberoptic nasal endoscopy and is a supplement to fiberoptic nasal endoscopy

  5. Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.

    Science.gov (United States)

    Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert

    2006-11-01

    Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.

  6. Appropriateness of upper-GI endoscopy: an Italian survey on behalf of the Italian Society of Digestive Endoscopy.

    Science.gov (United States)

    Hassan, Cesare; Bersani, Gianluca; Buri, Luigi; Zullo, Angelo; Anti, Marcello; Bianco, Maria Antonia; Di Giulio, Emilio; Ficano, Leonardo; Morini, Sergio; Di Matteo, Giovanni; Loriga, Piero; Pietropaolo, Vincenzo; Cipolletta, Livio; Costamagna, Guido

    2007-05-01

    Open-access endoscopy allows physicians to directly schedule endoscopic procedures for their patients without prior consultation. An evaluation of both appropriateness and diagnostic yield of endoscopic procedures is critical when assessing the costs and benefits of endoscopy in an open-access setting. The aim of this Italian multicenter study was to assess the appropriate use of upper endoscopy (EGD) in an open-access system and to establish the yield of diagnostic information relevant to patient care. Cross-sectional, prospective, multicenter study. A total of 6270 patients referred to 44 Italian centers for open-access EGD during 1 month were prospectively enrolled. The American Society for Gastrointestinal Endoscopy (ASGE) guidelines were used to assess the relation between the appropriate use of EGD and the presence of relevant endoscopic findings. The rate for "generally not indicated" EGDs was 22.9%: 29.4% for primary care physicians and 12.9% for specialists (P 20, 99% CI 3 to >100; P < .01). Open-access EGD is an useful procedure for clinical practice. Because most of the relevant findings were detected during examinations performed for appropriate indications, the use of ASGE guidelines emerges as crucial to the cost-effectiveness of an open-access system.

  7. Current status of cleaning and disinfection for gastrointestinal endoscopy in China: a survey of 122 endoscopy units.

    Science.gov (United States)

    Zhang, Xiuli; Kong, Jinyan; Tang, Ping; Wang, Shufang; Hyder, Qurratulain; Sun, Gang; Zhang, Rugang; Yang, Yunsheng

    2011-04-01

    Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. To investigate cleaning and disinfection practice in China. A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China. One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious disease patients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently. Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  8. Development of a High Efficiency Dry Powder Inhaler: Effects of Capsule Chamber Design and Inhaler Surface Modifications

    Science.gov (United States)

    Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth

    2013-01-01

    Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD 90%, and ED > 80%. PMID:23949304

  9. Development of a high efficiency dry powder inhaler: effects of capsule chamber design and inhaler surface modifications.

    Science.gov (United States)

    Behara, Srinivas R B; Farkas, Dale R; Hindle, Michael; Longest, P Worth

    2014-02-01

    The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD  90%, and ED > 80%.

  10. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Marcos Rassi Fernandes

    Full Text Available OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66, predominantly female (90%, six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40% and six secondary (60%. RESULTS: the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (p<0.001. By the Constant Score (range of motion, there was an increase of 13.8 (average pre to 32 points (average post. CONCLUSION: the arthroscopic treatment proved effective in refractory adhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  11. Development of Multiple Capsule Robots in Pipe

    Directory of Open Access Journals (Sweden)

    Shuxiang Guo

    2018-05-01

    Full Text Available Swallowable capsule robots which travel in body cavities to implement drug delivery, minimally invasive surgery, and diagnosis have provided great potential for medical applications. However, the space constraints of the internal environment and the size limitations of the robots are great challenges to practical application. To address the fundamental challenges of narrow body cavities, a different-frequency driven approach for multiple capsule robots with screw structure manipulated by external electromagnetic field is proposed in this paper. The multiple capsule robots are composed of driven permanent magnets, joint permanent magnets, and a screw body. The screw body generates a propulsive force in a fluidic environment. Moreover, robots can form new constructions via mutual docking and release. To provide manipulation guidelines for active locomotion, a dynamic model of axial propulsion and circumferential torque is established. The multiple start and step-out frequencies for multiple robots are defined theoretically. Moreover, the different-frequency driven approach based on geometrical parameters of screw structure and the overlap angles of magnetic polarities is proposed to drive multiple robots in an identical electromagnetic field. Finally, two capsule robots were prototyped and experiments in a narrow pipe were conducted to verify the different motions such as docking, release, and cooperative locomotion. The experimental results demonstrated the validity of the driven approach for multiple capsule robots in narrow body cavities.

  12. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  13. Challenges in navigational strategies for flexible endoscopy

    NARCIS (Netherlands)

    van der Stap, N.; van der Heijden, Ferdinand; Broeders, Ivo Adriaan Maria Johannes

    Automating flexible endoscope navigation could lead to an increase in patient safety for endoluminal therapeutic procedures. Additionally, it may decrease the costs of diagnostic flexible endoscope procedures by shortening the learning curve and increasing the efficiency of insertion. Earlier

  14. A cost and time analysis of laryngology procedures in the endoscopy suite versus the operating room.

    Science.gov (United States)

    Hillel, Alexander T; Ochsner, Matthew C; Johns, Michael M; Klein, Adam M

    2016-06-01

    To assess the costs, charges, reimbursement, and efficiency of performing awake laryngology procedures in an endoscopy suite (ES) compared with like procedures performed in the operating room (OR). Retrospective review of billing records. Cost, charges, and reimbursements for the hospital, surgeon, and anesthesiologist were compared between ES injection laryngoplasty and laser excision procedures and matched case controls in the OR. Time spent in 1) the preoperative unit, 2) the operating or endoscopy suite, and 3) recovery unit were compared between OR and ES procedures. Hospital expenses were significantly less for ES procedures when compared to OR procedures. Reimbursement was similar for ES and OR injection laryngoplasty, though greater for OR laser excisions. Net balance (reimbursement-expenses) was greater for ES procedures. A predictive model of payer costs over a 3-year period showed similar costs for ES and OR laser procedures and reduced costs for ES compared to OR injection laryngoplasty. Times spent preoperatively and the procedure were significantly less for ES procedures. For individual laryngology procedures, the ES reduces time and costs compared to the OR, increasing otolaryngologist and hospital efficiency. This reveals cost and time savings of ES injection laryngoplasty, which occurs at a similar frequency as OR injection laryngoplasty. Given the increased frequency for ES laser procedures, total costs are similar for ES and OR laser excision of papilloma, which usually require repeated procedures. When regulated office space is unavailable, endoscopy rooms represent an alternative setting for unsedated laryngology procedures. NA Laryngoscope, 126:1385-1389, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  15. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anaesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    ), the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) and the European Society of Anaesthesiology (ESA). These three societies have endorsed the present guideline.The guideline is published simultaneously in the Journals Endoscopy and European Journal of Anaesthesiology....

  16. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.

    Science.gov (United States)

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-08-01

    At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.

  17. SMAC — A Modular Open Source Architecture for Medical Capsule Robots

    Directory of Open Access Journals (Sweden)

    Beccani Marco

    2014-11-01

    Full Text Available The field of Medical Capsule Robots (MCRs is gaining momentum in the robotics community, with applications spanning from abdominal surgery to gastrointestinal (GI endoscopy. MCRs are miniature multifunctional devices usually constrained in both size and on-board power supply. The design process for MCRs is time consuming and resource intensive, as it involves the development of custom hardware and software components. In this work, we present the STORM Lab Modular Architecture for Capsules (SMAC, a modular open source architecture for MCRs aiming to provide the MCRs research community with a tool for shortening the design and development time for capsule robots. The SMAC platform consists of both hardware modules and firmware libraries that can be used for developing MCRs. In particular, the SMAC modules are miniature boards of uniform diameter (i.e., 9.8 mm that are able to fulfill five different functions: signal coordination combined with wireless data transmission, sensing, actuation, powering and vision/illumination. They are small in size, low power, and have reconfigurable software libraries for the Hardware Abstraction Layer (HAL, which has been proven to work reliably for different types of MCRs. A design template for a generic SMAC application implementing a robust communication protocol is presented in this work, together with its finite state machine abstraction, capturing all the architectural components involved. The reliability of the wireless link is assessed for different levels of data transmission power and separation distances. The current consumption for each SMAC module is quantified and the timing of a SMAC radio message transmission is characterized. Finally, the applicability of SMAC in the field of MCRs is discussed by analysing examples from the literature.

  18. The first capsule implosion experiments on Orion

    International Nuclear Information System (INIS)

    Garbett, W J; Horsfield, C J; Gales, S G; Leatherland, A E; Rubery, M S; Coltman, J E; Meadowcroft, A E; Rice, S J; Simons, A J; Woolhead, V E

    2016-01-01

    Direct drive capsule implosions are being developed on the Orion laser at AWE as a platform for ICF and HED physics experiments. The Orion facility combines both long pulse and short-pulse beams, making it well suited for studying the physics of alternative ignition approaches. Orion implosions also provide the opportunity to study aspects of polar direct drive. Limitations on drive symmetry from the relatively small number of laser beams makes predictive modelling of the implosions challenging, resulting in some uncertainty in the expected capsule performance. Initial experiments have been fielded to evaluate baseline capsule performance and inform future design optimization. Highly promising DD fusion neutron yields in excess of 10 9 have been recorded. Results from the experiments are presented alongside radiation-hydrocode modelling. (paper)

  19. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Freud, A.; Hirshfeld, N.; Canfi, A.; Melamud, Y.

    1997-01-01

    Radioiodine ( 131 I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  20. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  1. Semipermeable Capsules Wrapping a Multifunctional and Self-regulated Co-culture Microenvironment for Osteogenic Differentiation

    Science.gov (United States)

    Correia, Clara R.; Pirraco, Rogério P.; Cerqueira, Mariana T.; Marques, Alexandra P.; Reis, Rui L.; Mano, João F.

    2016-02-01

    A new concept of semipermeable reservoirs containing co-cultures of cells and supporting microparticles is presented, inspired by the multi-phenotypic cellular environment of bone. Based on the deconstruction of the “stem cell niche”, the developed capsules are designed to drive a self-regulated osteogenesis. PLLA microparticles functionalized with collagen I, and a co-culture of adipose stem (ASCs) and endothelial (ECs) cells are immobilized in spherical liquified capsules. The capsules are coated with multilayers of poly(L-lysine), alginate, and chitosan nano-assembled through layer-by-layer. Capsules encapsulating ASCs alone or in a co-culture with ECs are cultured in endothelial medium with or without osteogenic differentiation factors. Results show that osteogenesis is enhanced by the co-encapsulation, which occurs even in the absence of differentiation factors. These findings are supported by an increased ALP activity and matrix mineralization, osteopontin detection, and the up regulation of BMP-2, RUNX2 and BSP. The liquified co-capsules also act as a VEGF and BMP-2 cytokines release system. The proposed liquified capsules might be a valuable injectable self-regulated system for bone regeneration employing highly translational cell sources.

  2. Design Improvements of the Capsule Components and the Handling Tools for an Effective Utilization of the Capsule Assembly Machine

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, Jong Kium; Youm, Ki Un; Yoon, Ki Byung; Choi, Myung Hwan; Kim, Bong Gu

    2006-01-01

    Various in-pile test programs for the development of new fuels and materials are planned for the HANARO reactor. To meet the demands for the required tests in the HANARO reactor, new capsule assembling technology is required in the HANARO reactor. For this reason, a series of analyses and experiments was performed in 2005. For the assembly workability tests of the capsule components, three different kinds of protection tubes and two different shapes of the locking bolt heads were proposed and tested. It was confirmed that the newly designed protection tube and bolts worked quite well without any problems. Since the new structure is quite similar to that of the currently used capsule, it was assumed that an additional vibration tests and seismic analysis would not be needed. Through the stress analysis of the three proposed structures by using ANSYS code, it showed that the maximum displacement and stress intensity for the tube reducer were 1.57mm and 21MPa, respectively. To improve the workability and handling capability of the bolting and clamping tools of stainless steel 304, Al6061/T6 was selected as one of the candidates and thus new tools were manufactured and tested. The assembly test results showed that the new tools were found to be useful for executing key tasks such as a bolting and a clamping and they were much faster than the old tools made of stainless steel, thereby increasing the workability rate and lowering the manufacturing costs

  3. Recurrent Lower Gastrointestinal Bleeding: Ileal GIST Diagnosed by Video Capsule Endoscopy—A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Jie Ling

    2013-01-01

    Full Text Available Introduction. Gastrointestinal stromal tumor (GIST in the ileum is an extremely rare cause of recurrent lower gastrointestinal bleeding (GIB. Case Report. An 89-year-old man was admitted with melana. He had extensive PMH of CAD post-CABG/AICD, AAA repair, chronic anemia, myelodysplastic syndrome, lung cancer after resection, and recurrent GIB. Prior EGDs, colonoscopies, and upper device-assisted enteroscopy showed duodenal ulcer, A-V malformation s/p cauterization, and angioectasia. On admission, Hb was 6.0 g/dL. An endoscopic capsule study showed an ulcerated tumor in the ileum. CT showed no distant metastasis. The lesion was resected successfully and confirmed as a high-grade GIST. The patient was discharged with no further bleeding. Discussion. Early diagnosis for patients with ileal GIST is often challenging. Video capsule endoscopy and double balloon enteroscopy could be useful diagnostic tools. Surgical removal is the first line for a resectable GIST. Imatinib has become the standard therapy. Conclusion. This is a unique case of an ileal GIST in a patient with recurrent GIB which was diagnosed by video capsule. Complicated medical comorbidities often lead to a significant delay in diagnosis. Therefore, we recommend that if GIB does not resolve after appropriate treatments for known causes, the alternative diagnosis for occult GIB must be considered, including malignancy such as GIST.

  4. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    Science.gov (United States)

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75

  5. Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures

    Directory of Open Access Journals (Sweden)

    Basavana G Goudra

    2013-01-01

    Full Text Available Aims and Objectives: Continuous flow left ventricular assist devices (LVAD have emerged as a reliable treatment option for heart failure. Because of bleeding secondary to anticoagulation, these patients present frequently for gastrointestinal (GI endoscopy. The presently available literature on perioperative management of these patients is extremely limited and is primarily based upon theoretical principles. Materials and Methods: Perioperative records of patients with LVAD undergoing (GI endoscopy between 2008 and 2012 were reviewed. Patient, device and procedure specific information was analyzed. Results: A total of 105 LVADs were implanted, and 68 procedures were performed in 39 patients. The most common indication was GI bleed (48/68, with yearly risk of 8.57% per patient. A total of 63 procedures were performed under deep sedation, with five procedures requiring general anesthesia. Intra-procedure hypotension was managed by fluids and (or vasopressors/inotropes (phenylephrine, ephedrine or milrinone guided by plethysmographic waveform, non-invasive blood pressure (NIBP and LVADs pulsatility index (for HeartMate II/flow pulsatility (for HeartWare. No patient required invasive monitoring and both NIBP and pulse oximeter could be reliably used for monitoring (and guided management in all patients due to the presence of native heart′s pulsatile output. Conclusion: In the presence of residual heart function, with optimal device settings, non-invasive hemodynamic monitoring can be reliably used in these patients while undergoing GI endoscopy under general anesthesia or monitored anesthesia care. Transient hypotensive episodes respond well to fluids/vasopressors without the need of increasing device speed that can be detrimental.

  6. Pre-Procedural Patient Education Reduces Fall Risk in an Outpatient Endoscopy Suite.

    Science.gov (United States)

    Hilscher, Moira B; Niesen, Cynthia R; Tynsky, Desiree A; Kane, Sunanda V

    The purpose of this article was to determine whether scripted pre-procedural fall risk patient education and nurses' intention to assist patients after receiving sedation improves receptiveness of nursing assistance during recovery and decreases fall risk in an outpatient endoscopy suite. We prospectively identified high fall risk patients using the following criteria: (1) use of an assistive device, (2) fallen two or more times within the last year, (3) sustained an injury in a fall within a year, (4) age greater than 85 years, or (5) nursing judgment of high fall risk. Using a scripted dialogue, nurses educated high-risk patients of their fall risk and the nurses' intent to assist them to and in the bathroom. Documentation of patient education, script use, and assistance was monitored. Over 24 weeks, 892 endoscopy patients were identified as high fall risk; 790 (88.5%) accepted post-procedural assistance. Documentation of assistance significantly increased from 33% to 100%. Patients receiving education and postprocedural assistance increased from 27.9% to 100% at week 24. No patient falls occurred 12 months following implementation among patients identified as high fall risk. Scripted pre-procedural fall risk education increases patient awareness and receptiveness to assistance and can lead to decreased fall rates.

  7. Fully wireless pressure sensor based on endoscopy images

    Science.gov (United States)

    Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni

    2018-04-01

    In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.

  8. Computer vision and augmented reality in gastrointestinal endoscopy

    Science.gov (United States)

    Mahmud, Nadim; Cohen, Jonah; Tsourides, Kleovoulos; Berzin, Tyler M.

    2015-01-01

    Augmented reality (AR) is an environment-enhancing technology, widely applied in the computer sciences, which has only recently begun to permeate the medical field. Gastrointestinal endoscopy—which relies on the integration of high-definition video data with pathologic correlates—requires endoscopists to assimilate and process a tremendous amount of data in real time. We believe that AR is well positioned to provide computer-guided assistance with a wide variety of endoscopic applications, beginning with polyp detection. In this article, we review the principles of AR, describe its potential integration into an endoscopy set-up, and envisage a series of novel uses. With close collaboration between physicians and computer scientists, AR promises to contribute significant improvements to the field of endoscopy. PMID:26133175

  9. Complementary roles of interventional radiology and therapeutic endoscopy in gastroenterology

    DEFF Research Database (Denmark)

    Ray, David M; Srinivasan, Indu; Tang, Shou-Jiang

    2017-01-01

    radiology have resulted in the paradigm shift in the management of these conditions. In this paper, we discuss the patient's work up, indications, and complementary roles of endoscopic and angiographic management in the settings of gastrointestinal bleeding, enteral feeding, cecostomy tube placement...... and luminal strictures. These conditions often require multidisciplinary approaches involving a team of interventional radiologists, gastroenterologists and surgeons. Further, the authors also aim to describe how the fields of interventional radiology and gastrointestinal endoscopy are overlapping...

  10. First progress report on the Japan Endoscopy Database project.

    Science.gov (United States)

    Kodashima, Shinya; Tanaka, Kiyohito; Matsuda, Koji; Fujishiro, Mitsuhiro; Saito, Yutaka; Ohtsuka, Kazuo; Oda, Ichiro; Katada, Chikatoshi; Kato, Masayuki; Kida, Mitsuhiro; Kobayashi, Kiyonori; Hoteya, Shu; Horimatsu, Takahiro; Matsuda, Takahisa; Muto, Manabu; Yamamoto, Hironori; Ryozawa, Shomei; Iwakiri, Ryuichi; Kutsumi, Hiromu; Miyata, Hiroaki; Kato, Mototsugu; Haruma, Ken; Fujimoto, Kazuma; Uemura, Naomi; Kaminishi, Michio; Tajiri, Hisao

    2018-01-01

    The Japan Endoscopy Database (JED) Project was started to develop the world's largest endoscopic database, capture the actual performance of endoscopic practice, and standardize the terminology and fundamental items needed for a clinical and research registry. This paper presents a progress report on the first phase of this project undertaken at eight endoscopic centers in Japan. The list of data items to be collected was drafted by the MSED-J (Minimal Standard Endoscopic Database) subcommittee. These items were aggregated offline by integrating data from two endoscopic filing systems between July 2015 and December 2015. The study population included all patients who underwent esophagogastroduodenoscopy or colonoscopy at all eight centers, patients who underwent enteroscopy at five of the eight centers, and patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) at four of the eight centers. Data collected in this phase included 61 070 endoscopic procedures, of which 40 475 were esophagogastroduodenoscopies, 215 were enteroscopies, 19 204 were colonoscopies, and 1176 were ERCPs. Frequencies of complications were 0.68% for esophagogastroduodenoscopy, 0% for enteroscopy, 0.43% for colonoscopy, and 13.34% for ERCP. In addition, we obtained various data including Helicobacter pylori infection status, past history of endoscopy in patients who underwent enteroscopy or colonoscopy, and degree of difficulty of ERCP, although the frequencies of reporting were sometimes low, with some items <20%. Results of the first phase suggest that the JED project can provide vast quantities of useful data about endoscopic procedures. © 2017 Japan Gastroenterological Endoscopy Society.

  11. Gastrointestinal mucosal abnormalities using videocapsule endoscopy in systemic sclerosis.

    Science.gov (United States)

    Marie, I; Antonietti, M; Houivet, E; Hachulla, E; Maunoury, V; Bienvenu, B; Viennot, S; Smail, A; Duhaut, P; Dupas, J-L; Dominique, S; Hatron, P-Y; Levesque, H; Benichou, J; Ducrotté, P

    2014-07-01

    To date, there are no large studies on videocapsule endoscopy in systemic sclerosis (SSc). Consequently, the prevalence and features of gastrointestinal mucosal abnormalities in SSc have not been determined. To determine both prevalence and characteristics of gastrointestinal mucosal abnormalities in unselected patients with SSc, using videocapsule endoscopy. To predict which SSc patients are at risk of developing potentially bleeding gastrointestinal vascular mucosal abnormalities. Videocapsule endoscopy was performed on 50 patients with SSc. Prevalence of gastrointestinal mucosal abnormalities was 52%. Potentially bleeding vascular mucosal lesions were predominant, including: watermelon stomach (34.6%), gastric and/or small intestinal telangiectasia (26.9%) and gastric and/or small intestinal angiodysplasia (38.5%). SSc patients with gastrointestinal vascular mucosal lesions more often exhibited: limited cutaneous SSc (P = 0.06), digital ulcers (P = 0.05), higher score of nailfold videocapillaroscopy (P = 0.0009), anaemia (P = 0.02), lower levels of ferritin (P correlation between gastrointestinal vascular mucosal lesions and presence of severe extra-digestive vasculopathy (digital ulcers and higher nailfold videocapillaroscopy scores). This latter supports the theory that SSc-related diffuse vasculopathy is responsible for both cutaneous and digestive vascular lesions. Therefore, we suggest that nailfold videocapillaroscopy may be a helpful test for managing SSc patients. In fact, nailfold videocapillaroscopy score should be calculated routinely, as it may result in identification of SSc patients at higher risk of developing potentially bleeding gastrointestinal vascular mucosal lesions. © 2014 John Wiley & Sons Ltd.

  12. The Application of Hemospray in Gastrointestinal Bleeding during Emergency Endoscopy

    Directory of Open Access Journals (Sweden)

    Alexander F. Hagel

    2017-01-01

    Full Text Available Introduction. Gastrointestinal bleeding represents the main indication for emergency endoscopy (EE. Lately, several hemostatic powders have been released to facilitate EE. Methods. We evaluated all EE in which Hemospray was used as primary or salvage therapy, with regard to short- and long-term hemostasis and complications. Results. We conducted 677 EE in 474 patients (488 examinations in 344 patients were upper GI endoscopies. Hemospray was applied during 35 examinations in 27 patients (19 males, 33 during upper and 2 during lower endoscopy. It was used after previous treatment in 21 examinations (60% and in 14 (40% as salvage therapy. Short-term success was reached in 34 of 35 applications (97.1%, while long-term success occurred in 23 applications (65.7%. Similar long-term results were found after primary application (64,3% or salvage therapy (66,7%. Rebleeding was found in malignant and extended ulcers. One major adverse event (2.8% occurred with gastric perforation after Hemospray application. Discussion. Hemospray achieved short-term hemostasis in virtually all cases. The long-term effect is mainly determined by the type of bleeding source, but not whether it was applied as first line or salvage therapy. But, even in the failures, patients had benefit from hemodynamic stabilization and consecutive interventions in optimized conditions.

  13. The Results of Upper Gastrointestinal Endoscopy Performed in Bayburt Province

    Directory of Open Access Journals (Sweden)

    Yavuz Ayar

    2013-09-01

    Full Text Available Aim: We analyzed the results of upper gastrointestinal endoscopy performed between November 2011 and January 2013 in the endoscopy unit at Bayburt State Hospital. Methods: Endoscopic analyses were done with a PENTAX EPK 100P equipment. The results were assessed retrospectively. Results: A total of 1008 patients (664 women, 344 men aged between 17 and 88 (mean: 50±18 years have undergone upper gastrointestinal endoscopy. 186 (18.4% patients were diagnosed with pangastritis, 81 - with esophagitis (8%, 68 - with antral gastritis (6.7%, 67 - with duodenal ulcer (6.6%, 57 - with gastric ulcer (5.6%, 35 - with alkaline reflux gastritis (3.6%, 21 - with duodenitis (2.1%, 5 - with gastric cancer (0.5%, 4 - with esophagial cancer (0.4%, 4 - with gastric polyp (0.4% and 3 patients were diagnosed with esophagial ulcer (0.3%. Conclusion: Lesions were most commonly observed in the stomach. Gastritis, esophagitis, duodenal and gastric ulcer were frequently observed in our city. (The Medical Bulletin of Haseki 2013; 51: 116-9

  14. Twenty Strategies to Increase Student Motivation. Information Capsule. Volume 0907

    Science.gov (United States)

    Blazer, Christie

    2010-01-01

    Keeping students interested in school and motivating them to succeed are challenges that even the most experienced teachers face every year. A host of student variables can lead to low levels of motivation, but research indicates that educational settings also influence motivation levels. Some studies have found that motivation is a stronger…

  15. Physics of ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    The implosion of an ICF capsule must accomplish both compression of the main fuel to several hundred grams per cubic centimeter and heating and compression of the central region of the fuel to ignition. This report discusses the physics of these conditions

  16. Extended School Year. Information Capsule. Volume 0910

    Science.gov (United States)

    Blazer, Christie

    2010-01-01

    Extended school years are being considered by districts around the country as educators search for new ways to raise student achievement. The addition of time to the school calendar is also supported by President Barack Obama, who recently stated that American students do not spend enough time in school. This Information Capsule addresses research…

  17. Isolation of Capsulate Bacteria from Acute Dentoalveolar Abscesses

    OpenAIRE

    Lewis, M. A. O.; Milligan, S. G.; MacFarlane, T. W.; Carmichael, F. A.

    2011-01-01

    The presence of a capsule was determined for 198 bacterial strains (57 facultative anaerobes, 141 strict anaerobes) isobdted from pus samples aspirated from 40 acute dentoalveolar abscesses. A total of 133 (67 per cent) of the isolates (42 facultative anaerobes, 91 strict anaerobes) were found to have a capsule. Possession ofa capsule may in part explain the apparent pathogenicity of the bacterial species encountered in acute dentoalveolar abscess.Keywords - Bacterial capsule; Acute dentoalve...

  18. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    The application relates to an ingestible capsule (102) for delivery of a substance e.g. a pharmaceutical drug, to a human or animal. The ingestible capsule comprises a capsule wall structure (202) forming a substantially sealed reservoir or lumen holding the substance (204). An electrical resonance...

  19. Analytical Model for the Probability Characteristics of a Crack Penetrating Capsules in Capsule-Based Self-Healing Cementitious Materials

    Directory of Open Access Journals (Sweden)

    Zhong LV

    2017-08-01

    Full Text Available Autonomous crack healing using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of capsule-based self-healing materials. Continuing our previous study, in this contribution a more practical rupturing mode of capsules characterizing the rupturing manner of capsules fractured by cracks in cementitious materials is presented, i.e., penetrating mode. With the underlying assumption that a crack penetrating capsules undoubtedly leads to crack healing, geometrical probability theory is employed to develop the quantitative relationship between crack size and capsule size, capsule concentration in capsule-based self-healing virtual cementitious material. Moreover, an analytical expression of probability of a crack penetrating with randomly dispersed capsules is developed in two-dimensional material matrix setup. The influences of the induced rupturing modes of capsules embedded on the self-healing efficiency are analyzed. Much attention is paid to compare the penetrating probability and the hitting probability, in order to assist the designer to make a choice of the optimal rupturing modes of capsules embedded. The accuracy of results of the theoretical model is also compared with Monte-Carlo numerical analysis of crack interacting with capsules. It shows that the developed probability characteristics of a crack interaction with capsules for different rupturing modes is helpful to provide guidelines for designer working with capsule-based self-healing cementitious materials.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16888

  20. Upper GI endoscopy in elderly patients: predictive factors of relevant endoscopic findings.

    Science.gov (United States)

    Buri, Luigi; Zullo, Angelo; Hassan, Cesare; Bersani, Gianluca; Anti, Marcello; Bianco, Maria A; Cipolletta, Livio; Giulio, Emilio Di; Matteo, Giovanni Di; Familiari, Luigi; Ficano, Leonardo; Loriga, Piero; Morini, Sergio; Pietropaolo, Vincenzo; Zambelli, Alessandro; Grossi, Enzo; Tessari, Francesco; Intraligi, Marco; Buscema, Massimo

    2013-03-01

    Elderly patients are at increased risk for peptic ulcer and cancer. Predictive factors of relevant endoscopic findings at upper endoscopy in the elderly are unknown. This was a post hoc analysis of a nationwide, endoscopic study. A total of 3,147 elderly patients were selected. Demographic, clinical, and endoscopic data were systematically collected. Relevant findings and new diagnoses of peptic ulcer and malignancy were computed. Both univariate and multivariate analyses were performed. A total of 1,559 (49.5%), 213 (6.8%), 93 (3%) relevant findings, peptic ulcers, and malignancies were detected. Peptic ulcers and malignancies were more frequent in >85-year-old patients (OR 3.1, 95% CI = 2.0-4.7, p = 0.001). The presence of dysphagia (OR = 5.15), weight loss (OR = 4.77), persistent vomiting (OR = 3.68), anaemia (OR = 1.83), and male gender (OR = 1.9) were significantly associated with a malignancy, whilst overt bleeding (OR = 6.66), NSAIDs use (OR = 2.23), and epigastric pain (OR = 1.90) were associated with the presence of peptic ulcer. Peptic ulcer or malignancies were detected in 10% of elderly patients, supporting the use of endoscopy in this age group. Very elderly patients appear to be at higher risk of such lesions.

  1. Optimizing the villi visualization by tethered capsule OCT endomicroscopy for comprehensive imaging of human duodenum (Conference Presentation)

    Science.gov (United States)

    Dong, Jing; Gora, Michalina J.; Beaulieu-Ouellet, Emilie; Queneherve, Lucille H.; Grant, Catriona N.; Rosenberg, Mireille; Nishioka, Norman S.; Fasano, Alessio; Tearney, Guillermo J.

    2017-02-01

    Celiac disease (CD) affects around 1% of the global population and can cause serious long-term symptoms including malnutrition, fatigue, and diarrhea, amongst others. Despite this, it is often left undiagnosed. Currently, a tissue diagnosis of CD is made by random endoscopic biopsy of the duodenum to confirm the existence of microscopic morphologic alterations in the intestinal mucosa. However, duodenal endoscopic biopsy is problematic because the morphological changes can be focal and endoscopic biopsy is plagued by sampling error. Additionally, tissue artifacts can also an issue because cuts in the transverse plane can make duodenal villi appear artifactually shortened and can bias the assessment of intraepithelial inflammation. Moreover, endoscopic biopsy is costly and poorly tolerated as the patient needs to be sedated to perform the procedure. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. TCE involves swallowing an optomechanically-engineered pill that generates 3D images of the GI tract as it traverses the lumen of the organ via peristalsis, assisted by gravity. In several patients we have demonstrated TCE imaging of duodenal villi, however the current TCE device design is not optimal for CD diagnosis as the villi compress when in contact with the smooth capsule's wall. In this work, we present methods for structuring the outer surface of the capsule to improve the visualization of the villi height and crypt depth. Preliminary results in humans suggest that new TCE capsule enables better visualization of villous architecture, making it possibly to comprehensively scan the entire duodenum to obtain a more accurate tissue diagnosis of CD.

  2. Effects of glucosamine on proteoglycan loss by tendon, ligament and joint capsule explant cultures.

    Science.gov (United States)

    Ilic, M Z; Martinac, B; Samiric, T; Handley, C J

    2008-12-01

    To investigate the effect of glucosamine on the loss of newly synthesized radiolabeled large and small proteoglycans by bovine tendon, ligament and joint capsule. The kinetics of loss of (35)S-labeled large and small proteoglycans from explant cultures of tendon, ligament and joint capsule treated with 10mM glucosamine was investigated over a 10-day culture period. The kinetics of loss of (35)S-labeled small proteoglycans and the formation of free [(35)S]sulfate were determined for the last 10 days of a 15-day culture period. The proteoglycan core proteins were analyzed by gel electrophoresis followed by fluorography. The metabolism of tendon, ligament and joint capsule explants exposed to 10mM glucosamine was evaluated by incorporation of [(3)H]serine and [(35)S]sulfate into protein and glycosaminoglycans, respectively. Glucosamine at 10mM stimulated the loss of small proteoglycans from ligament explant cultures. This was due to the increased loss of both macromolecular and free [(35)S]sulfate to the medium indicating that glucosamine affected the release of small proteoglycans as well as their intracellular degradation. The degradation pattern of small proteoglycans in ligament was not affected by glucosamine. In contrast, glucosamine did not have an effect on the loss of large or small proteoglycans from tendon and joint capsule or large proteoglycans from ligament explant cultures. The metabolism of cells in tendon, ligament and joint capsule was not impaired by the presence of 10mM glucosamine. Glucosamine stimulated the loss of small proteoglycans from ligament but did not have an effect on small proteoglycan catabolism in joint capsule and tendon or large proteoglycan catabolism in ligament, tendon or synovial capsule. The consequences of glucosamine therapy at clinically relevant concentrations on proteoglycan catabolism in joint fibrous connective tissues need to be further assessed in an animal model.

  3. Apport de l'endoscopie digestive dans l'hypertension portale de l ...

    African Journals Online (AJOL)

    ... le rôle de l'endoscopie dans le traitement et la surveillance. Méthodes: Notre étude est une analyse rétrospective de 135 endoscopies digestives hautes effectuées chez 68 enfants atteints d'hypertension portale sur une période de 8 ans. Résultats: L'endoscopie a permis de mettre en évidence les varices oesogastriques ...

  4. White matter alterations in the internal capsule and psychomotor impairment in melancholic depression.

    Science.gov (United States)

    Hyett, Matthew P; Perry, Alistair; Breakspear, Michael; Wen, Wei; Parker, Gordon B

    2018-01-01

    Emerging evidence suggests that structural brain abnormalities may play a role in the pathophysiology of melancholic depression. We set out to test whether diffusion-derived estimates of white matter structure were disrupted in melancholia in regions underpinning psychomotor function. We hypothesized that those with melancholia (and evidencing impaired psychomotor function) would show disrupted white matter organization in internal capsule subdivisions. Diffusion magnetic resonance imaging (dMRI) data were acquired from 22 melancholic depressed, 23 non-melancholic depressed, and 29 healthy control participants. Voxel-wise fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) values were derived for anterior, posterior, and retrolenticular limbs of the internal capsule and compared between groups. Neuropsychological (reaction time) and psychomotor functioning were assessed and correlated against FA. Fractional anisotropy was distinctly increased, whilst RD was decreased, in the right anterior internal capsule in those with melancholia, compared to controls. The right anterior limb of the internal capsule correlated with clinical ratings of psychomotor disturbance, and reduced psychomotor speed was associated with increased FA values in the right retrolenticular limb in those with melancholia. Our findings highlight a distinct disturbance in the local white matter arrangement in specific regions of the internal capsule in melancholia, which in turn is associated with psychomotor dysfunction. This study clarifies the contribution of structural brain integrity to the phenomenology of melancholia, and may assist future efforts seeking to integrate neurobiological markers into depression subtyping.

  5. Glomerular parietal epithelial cell activation induces collagen secretion and thickening of Bowman's capsule in diabetes.

    Science.gov (United States)

    Holderied, Alexander; Romoli, Simone; Eberhard, Jonathan; Konrad, Lukas A; Devarapu, Satish K; Marschner, Julian A; Müller, Susanna; Anders, Hans-Joachim

    2015-03-01

    The metabolic and hemodynamic alterations in diabetes activate podocytes to increase extracellular matrix (ECM) production, leading to thickening of the glomerular basement membrane (GBM). We hypothesized that diabetes would activate parietal epithelial cells (PECs) in a similar manner and cause thickening of Bowman's capsules. Periodic acid Schiff staining of human kidney biopsies of 30 patients with diabetic nephropathy (DN) revealed a significantly thicker Bowman's capsule as compared with 20 non-diabetic controls. The average thickness was 4.55±0.21 μm in the group of patients with DN compared with 2.92±0.21 μm in the group of non-diabetic controls (PBowman's capsule showed strong association with CD44-positive PECs. In summary, metabolic alterations in diabetes activate PECs to increase the expression and secretion of Bowman's capsule proteins. This process may contribute to the thickening of the Bowman's capsule, similar to the thickening of the GBM that is driven by activated podocytes. These data may also imply that activated PECs contribute to ECM production once they migrate to the glomerular tuft, a process resulting in glomerular scaring, for example, in diabetic glomerulosclerosis.

  6. Gas1 expression in parietal cells of Bowman's capsule in experimental diabetic nephropathy.

    Science.gov (United States)

    Luna-Antonio, Brenda I; Rodriguez-Muñoz, Rafael; Namorado-Tonix, Carmen; Vergara, Paula; Segovia, Jose; Reyes, Jose L

    2017-07-01

    Gas1 (Growth Arrest-Specific 1) is a pleiotropic protein with novel functions including anti-proliferative and proapoptotic activities. In the kidney, the expression of Gas1 has been described in mesangial cells. In this study, we described that renal parietal cells of Bowman's capsule (BC) and the distal nephron cells also express Gas1. The role of Gas1 in the kidney is not yet known. There is a subpopulation of progenitor cells in Bowman's capsule with self-renewal properties which can eventually differentiate into podocytes as a possible mechanism of regeneration in the early stages of diabetic nephropathy. We analyzed the expression of Gas1 in the parietal cells of Bowman's capsule in murine experimental diabetes. We found that diabetes reduced the expression of Gas1 and increased the expression of progenitor markers like NCAM, CD24, and SIX1/2, and mesenchymal markers like PAX2 in the Bowman's capsule. We also analyzed the expression of WT1 (a podocyte-specific marker) on BC and observed an increase in the number of WT1 positive cells in diabetes. In contrast, nephrin, another podocyte-specific protein, decreases its expression in the first week of diabetes in the glomerular tuft, which is gradually restored during the second and third weeks of diabetes. These results suggest that in diabetes the decrease of Gas1 promotes the activation of parietal progenitor cells of Bowman's capsule that might differentiate into podocytes and compensate their loss observed in this pathology.

  7. Preparation and its drug release property of radiation-polymerized poly(methyl methacrylate) capsule including potassium chloride

    International Nuclear Information System (INIS)

    Yoshida, Masaru; Kumakura, Minoru; Kaetsu, Isao

    1979-01-01

    Porous flat circular capsules including KCl as a drug were prepared by radiation-induced polymerization of methyl methacrylate at room temperature in the presence of polyethylene glycol No. 600. The porous structure can be controlled by the methyl methacrylate-polyethylene glycol No. 600 composition. The amount of drug released was linearly related to the square root of time. The magnitude of drug release increased roughly in proportional to the water content of capsule, which can be related to porosity in the capsule. (author)

  8. Multispectral therapeutic endoscopy imaging and intervention

    Science.gov (United States)

    Bala, John L.; Schwaitzberg, Steven D.

    2007-02-01

    With the debut of antibiotic drug therapy, and as a result of its ease of use and general success in treating infection, drugs have become the treatment of choice for most bacterial infections. However, the advent of multiple, very aggressive drug-resistant bacteria, an increasing population which cannot tolerate drugs, and the high cost of drug therapy suggest that a new modality for treating infections is needed. The complex interplay of clonal spread, persistence, transfer of resistance elements and cell-to-cell interaction all contribute to the difficulty in developing drugs to treat new antibiotic-resistant bacterial strains. A dynamic non-drug system, using extant pulsed ultraviolet lightwave technology to kill infection, is being developed to destroy pathogens. This paper theorizes that the shock effect of pulsed xenon's high energy ultraviolet pulses at wavelengths between 250-270nm separates the bacteria's DNA bands, and, subsequently, destroys them. Preliminary laboratory tests have demonstrated the ability of the technology to destroy Staphylococcus aureus, Pseudomonas aeruginosa Escherichia coli, Helicobacter pylori, Acinetobacter baumannii, Klebsiella punemonia, Bacillus subtillis, and Aspergillus fumigates at penetration depths of greater than 3mm in fluids with 100% effectiveness in less than five seconds of exposure to pulsed xenon lightwaves. Micro Invasive Technology, Inc is developing .pulsed xenon therapeutic catheters and endoscopic instruments for internal antimicrobial eradication and topographical devices for prophylactic wound, burn and surgical entrance/exit site sterilization. Pulsed Xenon light sources have a broad optical spectrum (190-1200nm), and can generate light pulses with sufficient energy for combined imaging and therapeutic intervention by multiplexing a fiber optic pathway into the body. In addition, Pulsed Xenon has proven ability to activate photo reactive dyes; share endoscopic lightguides with lasers while, simultaneously

  9. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  10. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this evi......Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim...... of this evidence- and consensus-based set of guideline is to provide non-anesthesiologists with a comprehensive framework for propofol sedation during digestive endoscopy. This guideline results from a collaborative effort from representatives of the European Society of Gastrointestinal Endoscopy (ESGE...

  11. Alternative Agents to Prevent Fogging in Head and Neck Endoscopy

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2011-01-01

    Full Text Available Background The essential factor for diagnosis and treatment of diseases in head and neck endoscopy is the visibility of the image. An anti-fogging agent can reduce this problem by minimizing surface tension to prevent the condensation of water in the form of small droplets on a surface. There is no report on the use of hibiscrub ® or baby shampoo to reduce fogging in the literature. The objective of this study was to compare the efficacy between commercial anti-fogging agent, hibiscrub ® and baby shampoo to reduce fogging for the use in head and neck endoscopy. Methods The study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University in August 2010. Commercial anti-fogging agent, baby shampoo and hibiscrub ® were applied on rigid endoscope lens before putting them into a mist generator. The images were taken at baseline, 15 seconds, 30 seconds and 1 minute. The images' identifiers were removed before they were sent to two evaluators. A visual analogue scale (VAS was used to rate the image quality from 0 to 10. Results The difference in mean VAS score between anti-fogging agent, baby shampoo and hibiscrub ® versus no agent were 5.46, 4.45 and 2.1 respectively. The commercial anti-fogging agent and baby shampoo had most protective benefit and performed significantly better than no agent ( P < 0.05. Conclusions Baby shampoo is an effective agent to prevent fogging during head and neck endoscopy and compares favourably with commercial anti-fogging agent.

  12. Anti-proliferative effect of olmesartan on Tenon's capsule fibroblasts

    Directory of Open Access Journals (Sweden)

    Xuan Wang

    2016-05-01

    Full Text Available AIM: To evaluate the inhibitive effect of olmesartan to fibroblast proliferation and the anti-scarring effect in Tenon’s capsule, both in vitro and in vivo. METHODS: Human primary Tenon’s capsule fibroblasts were cultured in vitro, treated with up titrating concentrations of olmesartan. The rate of inhibition was tested with methyl thiazol tetrazolium (MTT method. Real-time PCR was performed to analyze changes in mRNA expressions of the fibrosis-related factors: matrix metalloproteinase-2 (MMP-2, tissue inhibitor of metalloproteinase (TIMP-1,2 and proliferating cell nuclear antigen (PCNA. Thirty rabbits were divided into 5 groups (3, 7, 14, 21, and 28d. A rabbit conjunctiva flap model was created in each eye. Olmesartan solution was injected subconjunctivally and then evaluated its anti-proliferation and anti-fibrosis effects through the histological morphology and immunohistochemistry of MMP-2 and PCNA in each group. Only the 7d group was treated with Masson’s trichrome to compare the neovascularization in the subconjunctiva area. RESULTS: In vitro, cultured Tenon's capsule human fibroblasts showed a dose dependent inhibition by olmesartan in MTT. Olmesartan reduced mRNA expressions of MMP-2 and PCNA but increased mRNA expressions of TIMP-1 and TIMP-2. In vivo, the rabbit eyes treated with olmesartan at 3rd, 7th, 14th and 21st days demonstrated a significant reduced expressions of MMP-2 and PCNA compared with control eye, no significant difference observed in 28th day group. The cellular proliferation and neovascularization was suppressed by olmesartan in Masson’s trichrome observation. CONCLUSION: By inhibiting fibroblasts in vitro and in vivo, olmesartan prevents the proliferation and activity of fibroblasts in scar tissue formation, which might benefit glaucoma filtering surgery.

  13. Radiation research of materials using irradiation capsules

    International Nuclear Information System (INIS)

    Chamrad, B.

    1976-01-01

    The methods are briefly characterized of radiation experiments on the WWR-S research reactor. The irradiation capsule installed in the reactor including the electronic instrumentation is described. Irradiated samples temperature is stabilized by an auxiliary heat source placed in the irradiation space. The electronic control equipment of the system is automated. In irradiation experiments, experimental and operating conditions are recorded by a digital measuring centre with electric typewriter and paper tape data recording and by an analog compensating recorder. The irradiation experiment control system controls irradiated sample temperature, the supply current size and the heating element temperature of the auxiliary stabilizing source, inert and technological pressures of the capsule atmosphere and the thermostat temperature of the thermocouple junctions. (O.K.)

  14. Simulation-based patient flow analysis in an endoscopy unit

    DEFF Research Database (Denmark)

    Koo, Pyung-Hoi; Nielsen, Karl Brian; Jang, Jaejin

    2010-01-01

    One of the major elements in improving efficiency of healthcare services is patient flow. Patients require a variety of healthcare resources as they receive healthcare services. Poor management of patient flow results in long waiting time of patients, under/over utilization of medical resources......, low quality of care and high healthcare cost. This article addresses patient flow problems at a Gastrointestinal endoscopy unit. We attempt to analyze the main factors that contribute to the inefficient patient flow and process bottlenecks and to propose efficient patient scheduling and staff...

  15. New techniques for evaluating the gastrointestinal tract: capsular endoscopy

    Directory of Open Access Journals (Sweden)

    A E Karateyev

    2009-01-01

    Full Text Available The paper describes a procedure for capsular endoscopy (CE, a new high-technology method of evaluating the small bowel, and reports on its use in rheumatological care. Small bowel involvement is noted to be frequently encountered in rheumatic diseases, such as Behcet's disease, diffuse scleroderma, and seronegative spondylitis. According to the data of clinical trials, CE is effective in timely detecting this visceral abnormality. At the same time, CE is actually the only accurate method of diagnosing drug-induced enteropathy, a potentially menacing disease that frequently occurs with the use of nonsteroidal anti-inflammatory drugs.

  16. The Clinical Risks of Infection Associated with Endoscopy

    Directory of Open Access Journals (Sweden)

    Alistair E Cowen

    2001-01-01

    Full Text Available The cleaning of flexible endoscopes is difficult and time consuming. Any method of attempted sterilization or high level disinfection will fail if prior cleaning has been defective. Inadequate reprocessing of endoscopes may result in patient to patient transmission of serious bacterial and viral diseases or infection with endemic hospital pathogens. Antibiotic prophylaxis is required to prevent septicemia and bacterial endocarditis in high risk patients undergoing specific endoscopic procedures. Prevention of serious endoscopy-associated clinical infections requires strict compliance with detailed reprocessing protocols by specially trained nursing staff.

  17. Oral endoscopy in prosthodontic management of the soft palate defect.

    Science.gov (United States)

    Beery, Q C; Aramany, M A; Katzenberg, B

    1985-08-01

    Telescopic oral endoscopy is an effective aid in the construction and modification of a speech aid prosthesis. The method is noninvasive and easy to perform, permits the prosthodontist to achieve the goal of functional effectiveness in prosthesis construction while keeping the weight and size of the pharyngeal extension at a minimum, decreases the number and length of patient visits required for modification, and when coupled to a fiberoptic teaching arm or a video camera and recording system, it becomes an excellent aid in teaching, patient education and orientation, and record keeping.

  18. Identifying ambiguous prostate gland contours from histology using capsule shape information and least squares curve fitting

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Rania [DigiPen Institute of Technology, Department of Computer Engineering, Redmond, WA (United States); McKenzie, Frederic D. [Old Dominion University, Department of Electrical and Computer Engineering, Norfolk, VA (United States)

    2007-12-15

    To obtain an accurate assessment of the percentage and depth of extra-capsular soft tissue removed with the prostate by the various surgical techniques in order to help surgeons in determining the appropriateness of different surgical approaches. This can be enhanced by an accurate and automated means of identifying the prostate gland contour. To facilitate 3D reconstruction and, ultimately, more accurate analyses, it is essential for us to identify the capsule boundary that separates the prostate gland tissue from its extra-capsular tissue. However, the capsule is sometimes unrecognizable due to the naturally occurring intrusion of muscle and connective tissue into the prostate gland. At these regions where the capsule disappears, its contour can be arbitrarily created with a continuing contour line based on the natural shape of the prostate. We utilize an algorithm based on a least squares curve fitting technique that uses a prostate shape equation to merge previously detected capsule parts with the shape equation to produce an approximated curve that represents the prostate capsule. We have tested our algorithm using three different shapes on 13 histologic prostate slices that are cut at different locations from the apex. The best result shows a 90% average contour match when compared to pathologist-drawn contours. We believe that automatically identifying histologic prostate contours will lead to increased objective analyses of surgical margins and extracapsular spread of cancer. Our results show that this is achievable. (orig.)

  19. Identifying ambiguous prostate gland contours from histology using capsule shape information and least squares curve fitting

    International Nuclear Information System (INIS)

    Hussein, Rania; McKenzie, Frederic D.

    2007-01-01

    To obtain an accurate assessment of the percentage and depth of extra-capsular soft tissue removed with the prostate by the various surgical techniques in order to help surgeons in determining the appropriateness of different surgical approaches. This can be enhanced by an accurate and automated means of identifying the prostate gland contour. To facilitate 3D reconstruction and, ultimately, more accurate analyses, it is essential for us to identify the capsule boundary that separates the prostate gland tissue from its extra-capsular tissue. However, the capsule is sometimes unrecognizable due to the naturally occurring intrusion of muscle and connective tissue into the prostate gland. At these regions where the capsule disappears, its contour can be arbitrarily created with a continuing contour line based on the natural shape of the prostate. We utilize an algorithm based on a least squares curve fitting technique that uses a prostate shape equation to merge previously detected capsule parts with the shape equation to produce an approximated curve that represents the prostate capsule. We have tested our algorithm using three different shapes on 13 histologic prostate slices that are cut at different locations from the apex. The best result shows a 90% average contour match when compared to pathologist-drawn contours. We believe that automatically identifying histologic prostate contours will lead to increased objective analyses of surgical margins and extracapsular spread of cancer. Our results show that this is achievable. (orig.)

  20. Impacts of Implosion Asymmetry And Hot Spot Shape On Ignition Capsules

    Science.gov (United States)

    Cheng, Baolian; Kwan, Thomas J. T.; Wang, Yi-Ming; Yi, S. Austin; Batha, Steve

    2017-10-01

    Implosion symmetry plays a critical role in achieving high areal density and internal energy at stagnation during hot spot formation in ICF capsules. Asymmetry causes hot spot irregularity and stagnation de-synchronization that results in lower temperatures and areal densities of the hot fuel. These degradations significantly affect the alpha heating process in the DT fuel as well as on the thermonuclear performance of the capsules. In this work, we explore the physical factors determining the shape of the hot spot late in the implosion and the effects of shape on Î+/-particle transport. We extend our ignition theory [1-4] to include the hot spot shape and quantify the effects of the implosion asymmetry on both the ignition criterion and capsule performance. We validate our theory with the NIF existing experimental data Our theory shows that the ignition criterion becomes more restrictive with the deformation of the hot spot. Through comparison with the NIF data, we demonstrate that the shape effects on the capsules' performance become more explicit as the self-heating and yield of the capsules increases. The degradation of the thermonuclear burn by the hot spot shape for high yield shots to date can be as high as 20%. Our theory is in good agreement with the NIF data. This work was performed under the auspices of the U.S. Department of Energy by the Los Alamos National Laboratory under Contract No. W-7405-ENG-36.

  1. Renal capsule for augmentation cystoplasty in canine model: a favorable biomaterial?

    Directory of Open Access Journals (Sweden)

    Mehdi Salehipour

    2016-04-01

    Full Text Available ABSTRACT Purpose: To evaluate effectiveness of canine renal capsule for augmentation cystoplasty. Materials and Methods: Ten adult dogs participated in this study. After induction of anesthesia each animal underwent bed side urodynamic study, bladder capacity and bladder pressure was recorded. Then via mid line incision abdominal cavity was entered, right kidney was identified and its capsule was dissected. Bladder augmentation was done by anastomosing the renal capsule to the bladder. After 6 months bed side urodynamic study was performed again and changes in bladder volume and pressure were recorded. Then the animals were sacrificed and the augmented bladders were sent for histopathology evaluation. Results: Mean maximum anatomic bladder capacity before cystoplasty was 334.00±11.40cc which increased to 488.00±14.83cc post-operatively (p=0.039. Mean anatomic bladder pressure before cystoplasty was 19.00±1.58cmH2O which decreased to 12.60±1.14cmH2O post-operatively (p=0.039. Histopathology evaluation revealed epithelialization of the renal capsule with urothelium without evidence of fibrosis, collagen deposits or contracture. Conclusions: Our data shows that renal capsule is a favorable biomaterial for bladder augmentation in a canine model.

  2. Heat transfer enhancement in energy storage in spherical capsules filled with paraffin wax and metal beads

    International Nuclear Information System (INIS)

    Ettouney, Hisham; Alatiqi, Imad; Al-Sahali, Mohammad; Al-Hajirie, Khalida

    2006-01-01

    Energy storage is an attractive option to conserve limited energy resources, where more than 50% of the generated industrial energy is discarded in cooling water and stack gases. This study focuses on the evaluation of heat transfer enhancement in phase change energy storage units. The experiments are performed using spherical capsules filled with paraffin wax and metal beads. The experiments are conducted by inserting a single spherical capsule filled with wax and metal beads in a stream of hot/cold air. Experimental measurements include the temperature field within the spherical capsule and in the air stream. To determine the enhancement effects of the metal beads, the measured data is correlated against those for a spherical capsule filled with pure wax. Data analysis shows a reduction of 15% in the melting and solidification times upon increasing the number and diameter of the metal beads. This reduction is caused by a similar decrease in the thermal load of the sphere due to replacement of the wax by metal beads. The small size of the spherical capsule limits the enhancement effects; this is evident upon comparison of the heat transfer in a larger size, double pipe energy storage unit, where 2% of the wax volume is replaced with metal inserts, result in a three fold reduction in the melting/solidification time and a similar enhancement in the heat transfer rate

  3. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  4. Effect of incorporation of nutraceutical capsule waste of safflower oil in the mechanical characteristics of corn starch films

    Directory of Open Access Journals (Sweden)

    Camila de CAMPO

    2016-01-01

    Full Text Available Abstract Biodegradable films blends made of safflower oil nutraceutical capsules waste corn starch (20:4, 30:4, 40:4 and 50:4 were prepared. The objective of this study was to evaluate the influence of addition of different concentrations of safflower oil nutraceutical capsule waste in the mechanical properties (tensile strength, elongation at break, Young’s modulus and thickness of corn starch films. A decrease in tensile strength and Young’s modulus and an increase in elongation at break were observed with the increase in the content of the nutraceutical capsule waste. The results showed that the blends of safflower oil capsules waste-corn starch films demonstrated promising characteristics to form biodegradable films with different mechanical characteristics.

  5. Imprinting on empty hard gelatin capsule shells containing titanium dioxide by application of the UV laser printing technique.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru; Terada, Katsuhide

    2014-08-01

    The purpose of this study was to examine the application of ultraviolet (UV) laser irradiation to printing hard gelatin capsule shells containing titanium dioxide (TiO2) and to clarify how the color strength of the printing by the laser could be controlled by the power of the irradiated laser. Hard gelatin capsule shells containing 3.5% TiO2 were used in this study. The capsules were irradiated with pulsed UV laser at a wavelength of 355 nm. The color strength of the printed capsule was determined by a spectrophotometer as total color difference (dE). The capsules could be printed gray by the UV laser. The formation of many black particles which were agglomerates of oxygen-defected TiO2 was associated with the printing. In the relationship between laser peak power of a pulse and dE, there were two inflection points. The lower point was the minimal laser peak power to form the black particles and was constant regardless of the dosage forms, for example film-coated tablets, soft gelatin capsules and hard gelatin capsules. The upper point was the minimal laser peak power to form micro-bubbles in the shells and was variable with the formulation. From the lower point to the upper point, the capsules were printed gray and the dE of the printing increased linearly with the laser peak power. Hard gelatin capsule shells containing TiO2 could be printed gray using the UV laser printing technique. The color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  6. Application of the UV laser printing technique to soft gelatin capsules containing titanium dioxide in the shells.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru

    2012-03-01

    The purpose of this study was to examine application of ultraviolet (UV) laser irradiation to printing soft gelatin capsules containing titanium dioxide (TiO(2)) in the shells and to study effect of UV laser power on the color strength of printing on the soft gelatin capsules. Size 6 Oval type soft gelatin capsules of which shells contained 0.685% TiO(2) and 0.005% ferric dioxide were used in this study. The capsules were irradiated pulsed UV laser at a wavelength 355 nm. The color strength of the printed capsules was determined by a spectrophotometer as total color difference (dE). The soft gelatin capsules which contained TiO(2) in the shells could be printed gray by the laser. Many black particles, which were associated with the printing, were formed at the colored parts of the shells. It was found that there were two inflection points in relationship between output laser energy of a pulse and dE. Below the lower point, the capsules were not printed. From the lower point to the upper point, the capsules were printed gray and total color difference of the printing increased linearly in proportion with the output laser energy. Beyond the upper point, total color difference showed saturation because of micro-bubbles formation at the laser irradiated spot. Soft gelatin capsules containing TiO(2) in the shells could be performed stable printing using the UV laser printing technique. Color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  7. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong Sun; Oh, Wan Ho; Yoo, Byung Ok; Jung, Yang Hong; Ahn, Sang Bok; Baik, Seung Je; Song, Wung Sup; Hong, Kwon Pyo

    2000-01-01

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  8. Mobile-cloud assisted video summarization framework for efficient management of remote sensing data generated by wireless capsule sensors.

    Science.gov (United States)

    Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook

    2014-09-15

    Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data.

  9. Mobile-Cloud Assisted Video Summarization Framework for Efficient Management of Remote Sensing Data Generated by Wireless Capsule Sensors

    Directory of Open Access Journals (Sweden)

    Irfan Mehmood

    2014-09-01

    Full Text Available Wireless capsule endoscopy (WCE has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data.

  10. Mobile-Cloud Assisted Video Summarization Framework for Efficient Management of Remote Sensing Data Generated by Wireless Capsule Sensors

    Science.gov (United States)

    Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook

    2014-01-01

    Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data. PMID:25225874

  11. Intragastric laparoscopic surgery: An option for gastric lesions not resectable by endoscopy.

    Science.gov (United States)

    Manuel Vázquez, Alba; Hernández Matías, Alberto; Bertomeu García, Agustín; Ruiz de Adana Belbel, Juan Carlos

    2016-03-01

    Gastric mucosal and submucosal lesions can be resected by endoscopy, laparoscopy or open surgery. Operative methods have varied depending on the location, endophytic growth and size of the lesion. Interest in minimally invasive surgery has increased and many surgeons are attempting laparoscopic approaches, especially in lesions of the stomach near the esophagogastric junction not amendable to endoscopic removal, because conventional surgery can produce stenosis and distort the postoperative anatomy, and increase morbimortality. We report our experience with laparoscopic intragastric surgery in 3 consecutive patients, with no complications. Laparoscopic intragastric surgery extends the surgeons' armamentarium to resect complex gastric lesions, while offering patients the benefits of minimal access surgery. Copyright © 2015 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Modeling and preliminary thermal analysis of the capsule for a creep test in HANARO

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Cho, Man Soon; Choo, Kee Nam; Kang, Young Hwan; Sohn, Jae Min; Shin, Yoon Taeg; Park, Sung Jae; Kim, Bong Goo; Kim, Young Jin

    2005-01-01

    A creep capsule is a device to investigate the creep characteristics of nuclear materials during inpile irradiation tests. To obtain the design data of the capsule through a preliminary thermal analysis, a 2-dimensional model for the cross section of the capsule including the specimens and components is generated, and an analysis using the ANSYS program is performed. The gamma-heating rates of the materials for the HANARO power of 30MW are considered, and the effect of the gap size and the control rod position on the temperature of the specimen is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. The temperature by increasing the position of the control rod is decreased

  13. Retinal hemodynamic influence of compound xueshuantong capsule on nonproliferative diabetic retinopathy after laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Yu-Yan Wang

    2014-07-01

    Full Text Available AIM: To observe retinal hemodynamic influence of compound xueshuantong capsule on nonproliferative diabetic retinopathy(NPDRafter laser photocoagulation. METHODS: A total of 41 patients(72 eyeswith NPDR after laser photocoagulation were enrolled in this study. They were all given compound xueshuantong capsule, and used color Doppler flow imaging for detection of retinal hemodynamics. RESULTS: After treatment, patients with retinal blood perfusion significantly improved; central retinal arterial peak systolic velocity(PSV, end-diastolic velocity(EDVand medial velocity(Vmwere increased, while the resistance index(RIdecreased. The difference have statistical significance(PCONCLUSION: Compound xueshuantong capsule can improve retinal blood perfusion for nonproliferative diabetic retinopathy after laser photocoagulation, which is related to improvement of visual prognosis.

  14. Optimization of Conditions for Obtaining Alginate/Olive Oil Capsules for Application in Dairy Industry

    Directory of Open Access Journals (Sweden)

    Poirieux Magalie

    2017-06-01

    Full Text Available Encapsulation is a process of incorporation of bioactive substances in a specific matrix. It results in increasing and/or maintaining of the biological agent concentration in the food matrix or the fermentation system. The encapsulation process is influenced by various factors. The aim of the present work was to investigate the influence of alginate type and concentration, homogenization rate and the oil phase amount in the preparation of capsules rich in olive oil. It has been found that emulsions obtained with medium viscosity alginate were characterized by better stability. To establish the joint influence of the factors was used screening design experiment, the optimization features selected being temperature, centrifugal and microscopic stability. The optimal levels of the factors were established and they we applied for capsule preparation. The obtained capsules showed maximum stability and possibility to be used in dairy product manufacture.

  15. Application of MR virtual endoscopy in children with hydrocephalus.

    Science.gov (United States)

    Zhao, Cailei; Yang, Jian; Gan, Yungen; Liu, Jiangang; Tan, Zhen; Liang, Guohua; Meng, Xianlei; Sun, Longwei; Cao, Weiguo

    2015-12-01

    To evaluate the performance of MR virtual endoscopy (MRVE) in children with hydrocephalus. Clinical and imaging data were collected from 15 pediatric patients with hydrocephalus and 15 normal control children. All hydrocephalus patients were confirmed by ventriculoscopy or CT imaging. The cranial 3D-T1 weighted imaging data from fast spoiled gradient echo scan (FSPGR) were transported to working station. VE images of cerebral ventricular cavity were constructed with Navigator software. Cerebral ventricular MRVE can achieve similar results as ventriculoscopy in demonstrating the morphology of ventricular wall or intracavity lesion. In addition, MRVE can observe the lesion from distal end of obstruction, as well as other areas that are inaccessible to ventriculoscopy. MRVE can also reveal the pathological change of ventricular inner wall surface, and help determine patency of the cerebral aqueduct and fourth ventricle outlet. MR virtual endoscopy provides a non-invasive diagnostic modality that can be used as a supplemental approach to ventriculoscopy. However, its sensitivity and specificity need to be determined in the large study. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Flexor Digitorum Accessorius Longus: Importance of Posterior Ankle Endoscopy

    Directory of Open Access Journals (Sweden)

    Jorge Pablo Batista

    2015-01-01

    Full Text Available Endoscopy for the posterior region of the ankle through two portals is becoming more widespread for the treatment of a large number of conditions which used to be treated with open surgery years ago. The tendon of the flexor hallucis longus (FHL travels along an osteofibrous tunnel between the posterolateral and posteromedial tubercles of the talus. Chronic inflammation of this tendon may lead to painful stenosing tenosynovitis. The aim of this report is to describe two cases depicting an accessory tendon which is an anatomical variation of the flexor hallucis longus in patients with posterior friction syndrome due to posterior ankle impingement and associated with a posteromedial osteochondral lesion of the talus. The anatomical variation (FDAL described was a finding during an endoscopy of the posterior region of the ankle, and we have spared it by sectioning the superior flexor retinaculum only. The accessory flexor digitorum longus is an anatomical variation and should be taken into account when performing an arthroscopy of the posterior region of the ankle. We recommend this treatment on this type of injury although we admit this does not make a definite conclusion.

  17. Virtual endoscopy post-processing of helical CT data sets

    International Nuclear Information System (INIS)

    Dessl, A.; Giacomuzzi, S.M.; Springer, P.; Stoeger, A.; Pototschnig, C.; Voelklein, C.; Schreder, S.G.; Jaschke, W.

    1997-01-01

    Purpose: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n=2), the tracheobronchial system (n=3), the nasal sinuses (n=2), the colon (n=2), and the common carotid artery (n=1). Software developed specifically for virtual endoscopy ('Navigator') was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. Results: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Thorugh use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. Conclusions: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware. (orig.) [de

  18. Thermal characteristic test for saturated temperature type capsule

    International Nuclear Information System (INIS)

    Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki; Ohuchi, Mitsuo; Harayama, Yasuo

    1989-08-01

    The Japan Material Testing Reactor Project is developing a new type capsule so-called 'Saturated Temperature Capsule', as a part of irradiation technique improvement program. This type capsule, in which the water is supplied and boiled, bases on the conception of keeping the coolant at the saturated temperature and facilitating the temperature setting of specimens heated by gamma-ray in reactor. However, out-pile test was planned, because there were few usable data for design and operation of the capsule into which the coolant was injected. A out-pile apparatus, simulated the capsule with electric heaters, was fabricated and experiments were carried out, to obtain data concerning design and operation for the capsule into which the water was injected. As a structure of simulated capsule, a type of downward coolant supply was adopted. The downward coolant tube type injectes the water in the bottom of capsule by tube through the upper flange. Major objects of experiences were to grasp thermal features under operation and to provide performances of capsule control equipment. Experimental results proved that the temperature of water within the capsule was easily varied by controlling supply water flow rate, and that the control equipment was operated stably and safety. (author)

  19. Esophageal stenting for benign and malignant disease : European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    Spaander, Manon C W; Baron, Todd H; Siersema, Peter D; Fuccio, Lorenzo; Schumacher, Brigitte; Escorsell, Àngels; Garcia-Pagán, Juan-Carlos; Dumonceau, Jean-Marc; Conio, Massimo; de Ceglie, Antonella; Skowronek, Janusz; Nordsmark, Marianne; Seufferlein, Thomas; Van Gossum, André; Hassan, Cesare; Repici, Alessandro; Bruno, Marco J

    2016-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE), endorsed by the European Society for Radiotherapy and Oncology (ESTRO), the European Society of Digestive Endoscopy (ESDO), and the European Society for Clinical Nutrition and Metabolism (ESPEN).

  20. Relationship between timing of endoscopy and mortality in patients with peptic ulcer bleeding

    DEFF Research Database (Denmark)

    Laursen, Stig B; Leontiadis, Grigorios I; Stanley, Adrian J

    2017-01-01

    BACKGROUND AND AIMS: The optimal timing of endoscopy in patients with peptic ulcer bleeding (PUB) remains unclear. The aim of this study was to examine the association between timing of endoscopy and mortality in PUB. METHODS: In a nationwide cohort study based on a database of consecutive patients...

  1. Upper Gastro-Intestinal Endoscopy in Port Harcourt, Nigeria: An Audit

    African Journals Online (AJOL)

    Background: Accurate diagnosis of disease conditions using laboratory, imaging or endoscopic investigation is essential for appropriate treatment. There is paucity of data on upper GI endoscopy in Port-Harcourt. This audit of our early experience is intended to provide data on the pattern of endoscopy findings which is ...

  2. Summary of Guidelines for Infection Prevention and Control for Flexible Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Lawrence Hookey

    2013-01-01

    Full Text Available BACKGROUND: High-quality processes to ensure infection prevention and control in the delivery of safe endoscopy services are essential. In 2010, the Public Health Agency of Canada and the Canadian Association of Gastroenterology (CAG developed a Canadian guideline for the reprocessing of flexible gastrointestinal endoscopy equipment.

  3. [Human joint capsule in osteoarthrosis (morpholocical changes) (author's transl)].

    Science.gov (United States)

    Dettmer, N; Barz, B

    1977-07-29

    Morphological investigations of the joint capsules in osteoarthrotic-changed joints have given rise to doubts about the present theory of the causal aetiology of the osteoarthrosis. In every inspected and demonstrated illustration beside the partly normal capsules segments could be found every transition between mild regressive alterations and most massive proliferative changes of the conective tissue and the lining cell layer. It was extraordinary, that the strongly dilated vessels were filled with red blood cells. In another part of the same case was found a massive stricture caused by concentrically deposited substances, which were impregnated with collagenous fibers. Regeneration of the vessels frequently happened adjacent totally obstructed ones. Round-cell infiltrations, granulocytes or other indications of an inflammatory synovitis are found only in a few cases. The intracartilaginous enzymatic reactions, which have been much talked of and which were explained as characteristic of the osteoarthrosis cannot be the cause of the degradation of the cartilage, particularly, because of the normal cell count which is to be found in the synovial fluid. We can answer this problem, if we can prove that the substrates of the chondral metabolism themselves exert a direct or indirect influence on the interstitial connective tissue with induction of the powerful proliferation of the same tissue. The changes in the transit zone would be secondary and their effect on the lining cell layer would increase the progression of the arthrotic events.

  4. Performance of HTGR fuel in HFIR capsule HT-33

    International Nuclear Information System (INIS)

    Tiegs, T.N.; Robbins, J.M.

    1979-06-01

    Irradiation capsule HT-33 was a cooperative effort between General Atomic Company (GA) and Oak Ridge National Laboratory (ORNL). In this capsule ThO 2 particles (fabricated by GA), low-enriched uranium particles, inert carbon particles, and various fuel rod matrices were tested under accelerated irradiation in the High-Flux Isotope Reactor. Visual examination showed good irradiation behavior for fuel rods with slug-injected matrices (using a pitch binder) and warm-molded matrices (using a thermosetting resin binder). Rod debonding improved somewhat with fuel rods that used GLCC H-451 ground graphite shim particles rather than Speer fluid coke shim particles. Measurements of permeability (by inert gas intrusion) of the pyrocarbon on the inert particles showed that the disorder created by the neutron flux did not increase the inert gas permeability. Metallographic examination of Triso-coated particles irradiated both with and without an outer pyrocarbon coating revealed that the outer coating is necessary to suppress SiC degradation at temperatures above approximately 1375 0 C. The fission product behavior (determined by the electron microprobe) was similar in both low-enriched and high-enriched uranium particles made from weak-acid resins. Furthermore, fission product palladium caused severe SiC corrosion at time-averaged temperatures above 1400 0 C

  5. Self-expandable metal stents for obstructing colonic and extracolonic cancer: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    van Hooft, Jeanin E.; van Halsema, Emo E.; Vanbiervliet, Geoffroy; Beets-Tan, Regina G. H.; Dewitt, John M.; Donnellan, Fergal; Dumonceau, Jean-Marc; Glynne-Jones, Robert G. T.; Hassan, Cesare; Jiménez-Perez, Javier; Meisner, Søren; Muthusamy, V. Raman; Parker, Michael C.; Regimbeau, Jean-Marc; Sabbagh, Charles; Sagar, Jayesh; Tanis, Pieter J.; Vandervoort, Jo; Webster, George J.; Manes, Gianpiero; Barthet, Marc A.; Repici, Alessandro

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and

  6. Self-Expandable Metal Stents for Obstructing Colonic and Extracolonic Cancer: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    van Hooft, J. E.; van Halsema, E. E.; Vanbiervliet, G.; Beets-Tan, R. G. H.; DeWitt, J. M.; Donnellan, F.; Dumonceau, J. M.; Glynne-Jones, R. G. T.; Hassan, C.; Jimenez-Perez, J.; Meisner, S.; Muthusamy, V. Raman; Parker, M. C.; Regimbeau, J. M.; Sabbagh, C.; Sagar, J.; Tanis, P. J.; Vandervoort, J.; Webster, G. J.; Manes, G.; Barthet, M. A.; Repici, A.

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and

  7. Endoscopic findings in patients with upper gastrointestinal bleeding clinically classified into three risk groups prior to endoscopy

    OpenAIRE

    Tammaro, Leonardo; Paolo, Maria Carla Di; Zullo, Angelo; Hassan, Cesare; Morini, Sergio; Caliendo, Sebastiano; Pallotta, Lorella

    2008-01-01

    AIM: To investigate in a prospective study whether a simplified clinical score prior to endoscopy in upper gastrointestinal bleeding (UGIB) patients was able to predict endoscopic findings at urgent endoscopy.

  8. PERFORATION AS A COMPLICATION OF THE DIAGNOSTIC UPPER AND LOWER ENDOSCOPY OF THE GASTROINTESTINAL TRACT

    Directory of Open Access Journals (Sweden)

    Ivailo P. Vazharov

    2012-08-01

    Full Text Available Purpose: The purpose of this examination is to evaluate the risk of perforation during endoscopy of upper and lower gastrointestinal tract.Patients and methods used: 1210 diagnostic gastroduodenoscopies and 412 colonoscopies of hospitalized patients were performed by two experienced endoscopists for the period March 2007 – March 2012 at MHAT Varna, MMA. The endoscopies were performed without premedication and sedation. The patients were examined for complications of the procedure during and after the endoscopy. One of the most serious complications is the perforation of the oesophagus, stomach or the large intestine.Results: We had no perforations caused by the examination during the 1210 upper endoscopies performed. We had 2 perforations (0,48% from the 412 colonoscopies performed, which were treated successfully surgically.Conclusions: The perforation is a rare but serious complication of the endoscopy of gastrointestinal tract, which can be healed completely.

  9. Is there a need for bacterial endocarditis prophylaxis in patients undergoing gastrointestinal endoscopy?

    Science.gov (United States)

    Patanè, Salvatore

    2014-04-01

    Heart valve repair or replacement is a serious problem. Patients can benefit from an open dialogue between both cardiologists and gastroenterologists for the optimal effective patients care. The focused update on infective endocarditis of the American College of Cardiology/American Heart Association 2008 (ACC/AHA guidelines) and guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009) of the European Society of Cardiology (ESC guidelines) describe prophylaxis against infective endocarditis (IE) as not recommended for gastroscopy and colonoscopy in the absence of active infection but increasing evidence suggests that the role of IE antibiotic prophylaxis remains a dark side of the cardio-oncology prevention. New evidences concerning infective endocarditis due to Streptococcus bovis, Streptococcus agalactiae, Enterococcus faecalis, Enterococcus faecium, Enterococcus durans, and new findings indicate that there is a need for bacterial endocarditis prophylaxis in patients undergoing gastrointestinal endoscopy especially in elderly patients and in cancer and immunocompromised patients, to avoid serious consequences.

  10. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  11. Capsule development and utilization for material irradiation tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules

  12. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B G; Joo, K N [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  13. Production, deformation and mechanical investigation of magnetic alginate capsules

    Science.gov (United States)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  14. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  15. Capsule Shields the Function of Short Bacterial Adhesins

    OpenAIRE

    Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...

  16. Introduction to the physics of ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    Inertial Confinement Fusion is an approach to fusion which relies on the inertia of the fuel mass to provide confinement. To achieve conditions under which this confinement is sufficient for efficient thermonuclear burn, high gain ICF targets designed to be imploded directly by laser light. These capsules are generally a spherical shell which is filled with low density DT gas. The shell is composed of an outer region which forms the ablator and an inner region of frozen or liquid DT which forms the main fuel. Energy from the driver is delivered to the ablator which heats up and expands. As the ablator expands and blows outward, the rest of the shell is forced inward to conserve momentum. In this implosion process, several features are important. We define the in-flight-aspect-ratio (IFAR) as the ratio of the shell radius R as it implodes to its thickness ΔR. Hydrodynamic instabilities during the implosion impose limits on this ratio which results in a minimum pressure requirement of about 100 Mbar. The convergence ratio is defined as the ratio of the initial outer radius of the ablator to the final compressed radius of the hot spot. This hot spot is the central region of the compressed fuel which is required to ignite the main fuel in high gain designs. Typical convergence ratios are 30--40. To maintain a nearly spherical shape during the implosion, when convergence ratios are this large, the flux delivered to the capsule must be uniform to a few percent. The remainder of this paper discusses the conditions necessary to achieve thermonuclear ignition in these ICF capsules

  17. Welding of iridium heat source capsule components

    International Nuclear Information System (INIS)

    Mustaleski, T.M.; Yearwood, J.C.; Burgan, C.E.; Green, L.A.

    1991-01-01

    Interplanetary spacecraft have long used radioisotope thermoelectric generators (RTG) to produce power for instrumentation. These RTG produce electrical energy from the heat generated through the radioactive decay of plutonium-238. The plutonium is present as a ceramic pellet of plutonium oxide. The pellet is encapsulated in a containment shell of iridium. Iridium is the material of choice for these capsules because of its compatibility with the plutonium dioxide. The high-energy beam welding (electron beam and laser) processes used in the fabrication of the capsules has not been published. These welding procedures were originally developed at the Mound Laboratories and have been adapted for use at the Oak Ridge Y-12 Plant. The work involves joining of thin material in small sizes to exacting tolerances. There are four different electron beam welds on each capsule, with one procedure being used in three locations. There is also a laser weld used to seal the edges of a sintered frit assembly. An additional electron beam weld is also performed to seal each of the iridium blanks in a stainless steel waster sheet prior to forming. In the transfer of these welding procedures from one facility to another, a number of modifications were necessary. These modifications are discussed in detail, as well as the inherent problems in making welds in material which is only 0.005 in. thick. In summary, the paper discusses the welding of thin components of iridium using the high energy beam processes. While the peculiarities of iridium are pertinent to the discussion, much of the information is of general interest to the users of these processes. This is especially true of applications involving thin materials and high-precision assemblies

  18. Characterization of an aged WESF capsule

    International Nuclear Information System (INIS)

    Kenna, B.T.; Schultz, F.J.

    1983-07-01

    A joint effort by SNLA and ORNL was initiated for a detailed characterization of an 18-year-old WESF 137 Cs source which has been used in the Sandia Irradiator for Dried Sewage Solids. The study included evaluation of the inner and outer stainless steel capsules by optical metallography, electron microprobe, and physical testing. Analysis of the residual atmospheres within the two containers was also done. The CsCl was analyzed for isotopic content and impurities. No potential problem areas, including corrosion, were found

  19. Postirradiation examination of capsule GF-4

    International Nuclear Information System (INIS)

    Kovacs, W.J.; Sedlak, B.J.

    1980-10-01

    The GF-4 capsule test was irradiated in the SILOE reactor at Grenoble, France between April 8, 1975 and July 26, 1976. High-enriched uranium (HEU) UC 2 and weak acid resin (WAR) UC/sub x/O/sub y/ fissile and ThO 2 fertile particles were tested. Postirradiation examination of cured-in-place fuel rods showed no fuel rod/graphite element interaction. In addition, all rods exhibited adequate structural integrity. Irradiation-induced dimensional changes for rods containing all TRISO-coated fuel were consistent with model predictions; however, rods containing BISO-coated fuel exhibited greater volumetric contractions than predicted

  20. Stability analysis of directly driven Nif capsules

    Energy Technology Data Exchange (ETDEWEB)

    Goncharov, V.N.; Skupsky, S.; McKenty, P.W.; Delettrez, J.A.; Town, R.P.J. [Rochester Univ., NY (United States). Lab. for Laser Energetics; Cherfils-Clerouin, C. [CEA/DAM-Ile de France, DIF, 91 - Bruyeres Le Chatel (France)

    2000-07-01

    An analytical model is presented to study perturbation evolution at the ablation and inner surfaces of the imploding shell. The model describes the ablative Rayleigh-Taylor and Bell-Plesset instabilities. The initial conditions for the model are determined by using existing theories of laser imprint, ablative Richtmyer-Meshkov instability, 'feed-out' and by performing a series of 2-D ORCHID simulations. The model and simulations show that the direct-drive cryogenic {alpha} = 3 NIF capsules remain intact during the implosion if laser nonuniformities are smoothed by 2-D SSD used in the current direct-drive target designs. (authors)

  1. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    Someya, Hiroyuki; Endoh, Yasuichi; Hoshiya, Taiji; Niimi, Motoji; Harayama, Yasuo

    1990-11-01

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  2. Safety evaluation for packaging (onsite) singly encapsulated cesium chloride capsules

    International Nuclear Information System (INIS)

    Smyth, W.W.

    1997-01-01

    Three nonstandard Waste Encapsulation and Storage Facility (WESF) cesium chloride capsules are being shipped from WESF (225B building) to the 324 building. They would normally be shipped in the Beneficial Uses Shipping System (BUSS) cask under its US Department of Energy (DOE) license (DOE 1996), but these capsules are nonstandard: one has a damaged or defective weld in the outer layer of encapsulation, and two have the outer encapsulation removed. The 3 capsules, along with 13 other capsules, will be overpacked in the 324 building to meet the requirements for storage in WESF's pool

  3. Method of forming capsules containing a precise amount of material

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1986-06-24

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations there along and thus enable separation of the tube into said capsules. 7 figs.

  4. 21 CFR 520.1920 - Prochlorperazine, isopropamide sustained release capsules.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS... dogs in which gastrointestinal disturbances are associated with emotional stress. (2)(i) Capsules...

  5. Diagnostic and therapeutic capsules and method of producing

    International Nuclear Information System (INIS)

    Morcos, N.A.; Haney, T.A.; Wedeking, P.W.

    1981-01-01

    An article of manufacture comprising a pharmaceutical radioactive capsule formed essentially of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contract with fluids of the gastro-intestinal tract, and having a filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract said filler material being supported by said capsule. And a method of filling a pharmaceutical radioactive capsule comprising providing filler material supporting a pharmaceutically useful radioactive compound and transporting said filler material carrying a pharmaceutically useful radioactive compound into the chamber of said capsule

  6. Transgastric endoscopy--a new fashion, a new excitement!

    Science.gov (United States)

    Fritscher-Ravens, A

    2007-02-01

    Current flexible gastrointestinal endoscopy has been enriched by a new technique, transluminal endoscopic surgery, which has recently attracted an explosion of interest. To date, the established applications are few, but this review attempts to provide an overview of the present status of the procedures and of the development of the technical devices. The possible risks will be addressed as well as the potential benefits. Ethical issues and safeguards may need exploration. Above all, the principal developments in techniques for closure of incisions will be described here, including each of the methods and devices. Expansion in perspective as well as size is most important both in business and science, as it brings new dimensions to our lives and work. A steady state is a myth, in general, as it will be overtaken by new developments, that transform into new steady states which themselves will be superseded.

  7. Role of virtual reality simulation in endoscopy training.

    Science.gov (United States)

    Harpham-Lockyer, Louis; Laskaratos, Faidon-Marios; Berlingieri, Pasquale; Epstein, Owen

    2015-12-10

    Recent advancements in virtual reality graphics and models have allowed virtual reality simulators to be incorporated into a variety of endoscopic training programmes. Use of virtual reality simulators in training programmes is thought to improve skill acquisition amongst trainees which is reflected in improved patient comfort and safety. Several studies have already been carried out to ascertain the impact that usage of virtual reality simulators may have upon trainee learning curves and how this may translate to patient comfort. This article reviews the available literature in this area of medical education which is particularly relevant to all parties involved in endoscopy training and curriculum development. Assessment of the available evidence for an optimal exposure time with virtual reality simulators and the long-term benefits of their use are also discussed.

  8. Development of positron sensor for multi-modal endoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Shimazoe, Kenji, E-mail: shimazoe@it-club.jp [Department of Bioengineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Takahashi, Hiroyuki [Department of Nuclear Engineering and Management, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Fujita, Kaoru [Japan Atomic Energy Agency, 4-29 Tokaimura, 319-1184 Ibaraki (Japan); Mori, Hiroshi; Momose, Toshimitsu [Department of Bioengineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2011-08-21

    Endoscopy is an important inspection device to detect cancers in the human body, but there exists the case of cancer that is hard to detect with only an optical device. Double inspection with optical and radio images is preferable for high accuracy diagnosis, and real time radio imaging is also promising for real time surgery with an endoscope. We have simulated, designed and fabricated a Si-based positron imaging probe for more accurate cancer detection in multi-modality endoscope systems. The fabricated Si-based detector with 2 mm diameter and 1 mm thickness was tested with gamma and positron sources, and also tested to detect cancers in a tumor bearing mouse. The direct positron imaging could have an advantage over gamma imaging in its high sensitivity and resolution.

  9. Transforming a conventional theatre into a gynaecological endoscopy unit.

    Science.gov (United States)

    Anastasakis, E; Protopapas, A; Daskalakis, G; Papadakis, M; Milingos, S; Antsaklis, A

    2007-01-01

    Most minimally invasive procedures are now performed in operating rooms that were originally designed for traditional open surgery. We designed an endoscopic theatre based on our experience with special features specific for gynaecological endoscopy. We designed a detailed plan with an architect's aid of a gynaecological unit (based on a Greek presidential decree published in 1991). The space utilized was that of a conventional theatre. With the architectural plan we anticipated every area needed in a gynaecological endoscopic theatre. A twin theatre was considered appropriate in order for the surgical team to operate alternatively in one theatre while the other is being cleaned and prepared for use. The design of a unit dedicated to gynaecologic laparoscopy is a multidisciplinary task where the endoscopic surgeon undertakes an active and prominent role. It is a project with great benefits and rewards for all parties involved. We present our design for evaluation.

  10. About human taeniasis and Taenia saginata diagnosis by endoscopy.

    Science.gov (United States)

    Galán Puchades, María Teresa

    2016-10-01

    La carta al editor se refiere al artículo de Canaval-Zuleta et al. aceptado para publicación, titulado "Endoscopy as an alternative diagnostic and therapeutic technique for Taenia saginata". El trabajo presenta una serie de incorrecciones que deben ser aclaradas, o al menos parte de ellas en solo 300 palabras. La información sobre las vias de infeccion en taeniasis, así como la patogenia y técnicas de diagnóstico, no se ajustan a la realidad. Asimismo, ya está publicado que el diagnóstico por endoscopia es una técnica muy sensible pero nada específica, pues no permite distinguir entre las 3 especies humanas del género Taenia.

  11. A virtual outpatient department provides a satisfactory patient experience following endoscopy.

    Science.gov (United States)

    Ryan, Elizabeth M; Rogers, Ailín C; Hanly, Ann M; McCawley, Niamh; Deasy, Joseph; McNamara, Deborah A

    2014-03-01

    The purpose of this study was to investigate telephone follow-up of post-endoscopy patients as an alternative to attendance at the outpatient department. Access to outpatient appointments is often a target for improvement in healthcare systems. Increased outpatient clinic capacity is not feasible without investment and extra manpower in an already constrained service. Outpatient attendance was audited at a busy colorectal surgical service. A subset of patients appropriate for follow-up in a "virtual outpatient department" (VOPD) were identified. A pilot study was designed and involved telephone follow-up of low-risk endoscopic procedures. Patient satisfaction was assessed using the Medical Interview Satisfaction Scale (MISS), which is a standardised survey of patient satisfaction with healthcare experiences. This was conducted via anonymous questionnaire at the end of the study. Of a total of 166 patients undergoing endoscopy in the time period, 79 were prospectively recruited to VOPD follow-up based on eligibility criteria. Overall, 67 (84.8 %) were successfully followed up by telephone consultation; nine patients (11.4 %) were contacted by mail. The remaining three patients (3.8 %) were brought back to the OPD. Patients recruited were more likely to be younger (55.82 ± 14.96 versus 60.78 ± 13.97 years, P = 0.029) and to have had normal examinations (49.4 versus 31.0 %, χ (2) = 5.070, P = 0.025). Nearly three quarters of patients responded to the questionnaire. The mean scores for all four aspects of the MISS were satisfactory, and overall patients were satisfied with the VOPD experience. VOPD is a target for improved healthcare provision, with improved efficiency and a high patient satisfaction rate.

  12. Laparoscopic diverticulectomy with the aid of intraoperative gastrointestinal endoscopy to treat epiphrenic diverticulum

    Directory of Open Access Journals (Sweden)

    Lei Yu

    2016-01-01

    Full Text Available Objective: Most researchers believe that the presence of large epiphrenic diverticulum (ED with severe symptoms should lead to the consideration of surgical options. The choice of minimally invasive techniques and whether Heller myotomy with antireflux fundoplication should be employed after diverticulectomy became points of debate. The aim of this study was to describe how to perform laparoscopic transhiatal diverticulectomy (LTD and oesophagomyotomy with the aid of intraoperative gastrointestinal (GI endoscopy and how to investigate whether the oesophagomyotomy should be performed routinely after LTD. Patients and Methods: From 2008 to 2013, 11 patients with ED underwent LTD with the aid of intraoperative GI endoscopy at our department. Before surgery, 4 patients successfully underwent oesophageal manometry: Oesophageal dysfunction and an increase of the lower oesophageal sphincter pressure (LESP were found in 2 patients. Results: There were 2 cases of conversion to an open transthoracic procedure. Six patients underwent LTD, Heller myotomy and Dor fundoplication; and 3 patients underwent only LTD. The dysphagia and regurgitation 11 patients experienced before surgery improved significantly. Motor function studies showed that there was no oesophageal peristalsis in 5 patients during follow-up, while 6 patients showed seemingly normal oesophageal motility. The LESP of 6 patients undergoing LTD, myotomy and Dor fundoplication was 16.7 ± 10.2 mmHg, while the LESPs of 3 patients undergoing only LTD were 26 mmHg, 18 mmHg and 21 mmHg, respectively. In 4 cases experiencing LTD, myotomy and Dor fundoplication, the gastro-oesophageal reflux occurred during the sleep stage. Conclusions: LTD constitutes a safe and valid approach for ED patients with severe symptoms. As not all patients with large ED have oesophageal disorders, according to manometric and endoscopic results, surgeons can categorise and decide whether or not myotomy and antireflux surgery

  13. Laparoscopic diverticulectomy with the aid of intraoperative gastrointestinal endoscopy to treat epiphrenic diverticulum.

    Science.gov (United States)

    Yu, Lei; Wu, Ji-Xiang; Chen, Xiao-Hong; Zhang, Yun-Feng; Ke, Ji

    2016-01-01

    Most researchers believe that the presence of large epiphrenic diverticulum (ED) with severe symptoms should lead to the consideration of surgical options. The choice of minimally invasive techniques and whether Heller myotomy with antireflux fundoplication should be employed after diverticulectomy became points of debate. The aim of this study was to describe how to perform laparoscopic transhiatal diverticulectomy (LTD) and oesophagomyotomy with the aid of intraoperative gastrointestinal (GI) endoscopy and how to investigate whether the oesophagomyotomy should be performed routinely after LTD. From 2008 to 2013, 11 patients with ED underwent LTD with the aid of intraoperative GI endoscopy at our department. Before surgery, 4 patients successfully underwent oesophageal manometry: Oesophageal dysfunction and an increase of the lower oesophageal sphincter pressure (LESP) were found in 2 patients. There were 2 cases of conversion to an open transthoracic procedure. Six patients underwent LTD, Heller myotomy and Dor fundoplication; and 3 patients underwent only LTD. The dysphagia and regurgitation 11 patients experienced before surgery improved significantly. Motor function studies showed that there was no oesophageal peristalsis in 5 patients during follow-up, while 6 patients showed seemingly normal oesophageal motility. The LESP of 6 patients undergoing LTD, myotomy and Dor fundoplication was 16.7 ± 10.2 mmHg, while the LESPs of 3 patients undergoing only LTD were 26 mmHg, 18 mmHg and 21 mmHg, respectively. In 4 cases experiencing LTD, myotomy and Dor fundoplication, the gastro-oesophageal reflux occurred during the sleep stage. LTD constitutes a safe and valid approach for ED patients with severe symptoms. As not all patients with large ED have oesophageal disorders, according to manometric and endoscopic results, surgeons can categorise and decide whether or not myotomy and antireflux surgery after LTD will be conducted.

  14. Petrous bone fractures violating otic capsule.

    Science.gov (United States)

    Magliulo, Giuseppe; Ciniglio Appiani, Mario; Iannella, Giannicola; Artico, Marco

    2012-12-01

    This study presents our experience with a series of patients suffering from petrous bone fractures violating the otic capsule who underwent subtotal petrosectomy combined with eustachian tube, middle ear, and mastoid obliteration, with the goal of preventing cerebrospinal fluid (CSF) leak and meningitis. This study enrolled 26 patients between 1997 and 2011. The clinical symptoms, otoscopy, and preoperative and postoperative audiometry and facial function, as well as CSF leak or meningitis, were evaluated in each patient. The entire group underwent a subtotal petrosectomy using the technique described in detail by Fisch. In addition, each patient was interviewed using a questionnaire to evaluate the impact on quality of life. Intraoperatively, we found significant CSF leaks in 14 patients (42.5%). No patient reported other episodes of CSF leak or meningitis after the surgery. The patients' responses of facial nerve function were slightly worse than the House-Brackmann evaluation (50% versus 42.3%; p < 0.05). The vast majority (88.5%) of the patients experienced no social impact. Our findings suggest the importance of not underestimating the risk for CSF leak in the petrous bone fractures violating the otic capsule. Preoperative counseling regarding the various troublesome complications must adequately motivate candidates to undergo surgery by pointing out the positive impact of the proposed treatment.

  15. Potential value of Cs-137 capsules

    Energy Technology Data Exchange (ETDEWEB)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions.

  16. Potential value of Cs-137 capsules

    International Nuclear Information System (INIS)

    Bloomster, C.H.; Brown, D.R.; Bruno, G.A.; Hazelton, R.F.; Hendrickson, P.L.; Lezberg, A.J.; Tingey, G.L.; Wilfert, G.L.

    1985-04-01

    We determined the value of Cs-137 compared to Co-60 as a source for the irradiation of fruit (apples and cherries), pork and medical supplies. Cs-137, in the WESF capsule form, had a value of approximately $0.40/Ci as a substitute for Co-60 priced at approximately $1.00/Ci. The comparison was based on the available curies emitted from the surface of each capsule. We developed preliminary designs for fourteen irradiation facilities; seven were based on Co-60 and seven were based on Cs-137. These designs provided the basis for estimating capital and operating costs which, in turn, provided the basis for determining the value of Cs-137 relative to Co-60 in these applications. We evaluated the effect of the size of the irradiation facility on the value of Cs-137. The cost of irradiation is low compared to the value of the product. Irradiation of apples for disinfestation costs $.01 to .02 per pound. Irradiation for trichina-safe pork costs $.02 per pound. Irradiation of medical supplies for sterilization costs $.07 to .12 per pound. The cost of the irradiation source, either Co-60 or Cs-137, contributed only a minor amount to the total cost of irradiation, about 5% for the fruit and hog cases and about 20% for the medical supply cases. We analyzed the sensitivity of the irradiation costs and Cs-137 value to several key assumptions

  17. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  18. Impact of educational intervention on the inter-rater agreement of nasal endoscopy interpretation

    Science.gov (United States)

    Colley, Patrick; Mace, Jess C.; Schaberg, Madeleine R.; Smith, Timothy L.; Tabaee, Abtin

    2015-01-01

    OBJECTIVE Nasal endoscopy is integral to the evaluation of sinonasal disorders. However, prior studies have shown significant variability in the inter-rater agreement of nasal endoscopy interpretation amongst practicing rhinologists. The objective of the current study is to evaluate the inter-rater agreement of nasal endoscopy amongst otolaryngology residents from a single training program at baseline and following an educational intervention. METHODS 11 otolaryngology residents completed nasal endoscopy grading forms for 8 digitally recorded nasal endoscopic examinations. An instructional lecture reviewing nasal endoscopy interpretation was subsequently provided. The residents then completed grading forms for 8 different nasal endoscopic examinations. Inter-rate agreement amongst residents for the pre- and post-lecture videos was calculated using the unweighted Fleiss’ kappa statistic (Kf) and intra-class correlation agreement (ICC). RESULTS Inter-rater agreement improved from a baseline level of fair (Kf range 0.268–0.383) to a post-educational level of moderate (Kf range 0.401–0.547) for nasal endoscopy findings of middle meatus mucosa, middle turbinate mucosa, middle meatus discharge, sphenoethmoid recess mucosa, sphenoethmoid recess discharge and atypical lesions (ICC, pendoscopy interpretation amongst otolaryngology residents. The inter-rater agreement for the majority of the characteristics that were evaluated improved after educational intervention. Further study is needed to improve nasal endoscopy interpretation. PMID:25781864

  19. The cervical facet capsule and its role in whiplash injury: a biomechanical investigation.

    Science.gov (United States)

    Winkelstein, B A; Nightingale, R W; Richardson, W J; Myers, B S

    2000-05-15

    Cervical facet capsular strains were determined during bending and at failure in the human cadaver. To determine the effect of an axial pretorque on facet capsular strains and estimate the risk for subcatastrophic capsular injury during normal bending motions. Epidemiologic and clinical studies have identified the facet capsule as a potential site of injury and prerotation as a risk factor for whiplash injury. Unfortunately, biomechanical data on the cervical facet capsule and its role in whiplash injury are not available. Cervical spine motion segments were tested in a pure-moment test frame and the full-field strains determined throughout the facet capsule. Motion segments were tested with and without a pretorque in pure bending. The isolated facet was then elongated to failure. Maximum principal strains during bending were compared with failure strains, by paired t test. Statistically significant increases in principal capsular strains during flexion-extension loading were observed when a pretorque was applied. All measured strains during bending were significantly less than strains at catastrophic joint failure. The same was true for subcatastrophic ligament failure strains, except in the presence of a pretorque. Pretorque of the head and neck increases facet capsular strains, supporting its role in the whiplash mechanism. Although the facet capsule does not appear to be at risk for gross injury during normal bending motions, a small portion of the population may be at risk for subcatastrophic injury.

  20. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    Science.gov (United States)

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  1. Noninvasive control of rhodamine-loaded capsules distribution in vivo

    Science.gov (United States)

    Stelmashchuk, O.; Tarakanchikova, Y.; Seryogina, E.; Piavchenko, G.; Zherebtsov, E.; Dunaev, A.; Popov, A.; Meglinski, I.

    2018-04-01

    Using fluorescence spectroscopy system with fibre-optical probe, we investigated the dynamics of propagation and circulation in the microcirculatory system of experimental nanocapsules fluorescent-labelled (rhodamine TRITC) nanocapsules. The studies were carried out in clinically healthy Wistar rats. The model animals were divided into control group and group received injections of the nanocapsules. The fluorescent measurements conducted transcutaneously on the thigh surface. The administration of the preparation with the rhodamine concentration of 5 mg/kg of animal weight resulted in twofold increase of fluorescence intensity by reference to the baseline level. As a result of the study, it was concluded that fluorescence spectroscopy can be used for transdermal measurements of the rhodamine-loaded capsules in vivo.

  2. Canadian Association of Gastroenterology Consensus Guidelines on Safety and Quality Indicators in Endoscopy

    Directory of Open Access Journals (Sweden)

    David Armstrong

    2012-01-01

    Full Text Available Several organizations worldwide have developed procedure-based guidelines and/or position statements regarding various aspects of quality and safety indicators, and credentialing for endoscopy. Although important, they do not specifically address patient needs or provide a framework for their adoption in the context of endoscopy services. The consensus guidelines reported in this article, however, aimed to identify processes and indicators relevant to the provision of high-quality endoscopy services that will support ongoing quality improvement across many jurisdictions, specifically in the areas of ethics, facility standards and policies, quality assurance, training and education, reporting standards and patient perceptions.

  3. Effects of fibrin, thrombin, and blood on breast capsule formation in a preclinical model.

    Science.gov (United States)

    Marques, Marisa; Brown, Spencer A; Cordeiro, Natália D S; Rodrigues-Pereira, Pedro; Cobrado, M Luís; Morales-Helguera, Aliuska; Lima, Nuno; Luís, André; Mendanha, Mário; Gonçalves-Rodrigues, Acácio; Amarante, José

    2011-03-01

    The root cause of capsular contracture (CC) associated with breast implants is unknown. Recent evidence points to the possible role of fibrin and bacteria in CC formation. The authors sought to determine whether fibrin, thrombin, and blood modulated the histological and microbiological outcomes of breast implant capsule formation in a rabbit model. The authors carried out a case-control study to assess the influence of fibrin, thrombin, and blood on capsule wound healing in a rabbit model. Eighteen New Zealand white rabbits received four tissue expanders. One expander acted as a control, whereas the other expander pockets received one of the following: fibrin glue, rabbit blood, or thrombin sealant. Intracapsular pressure/volume curves were compared among the groups, and histological and microbiological evaluations were performed (capsules, tissue expanders, rabbit skin, and air). The rabbits were euthanized at two or four weeks. At four weeks, the fibrin and thrombin expanders demonstrated significantly decreased intracapsular pressure compared to the control group. In the control and fibrin groups, mixed inflammation correlated with decreased intracapsular pressure, whereas mononuclear inflammation correlated with increased intracapsular pressure. The predominant isolate in the capsules, tissue expanders, and rabbit skin was coagulase-negative staphylococci. For fibrin and thrombin, both cultures that showed an organism other than staphylococci and cultures that were negative were associated with decreased intracapsular pressure, whereas cultures positive for staphylococci were associated with increased intracapsular pressure. Fibrin application during breast implantation may reduce rates of CC, but the presence of staphylococci is associated with increased capsule pressure even in the presence of fibrin, so care should be taken to avoid bacterial contamination.

  4. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...

  5. Iodometric determination of ampicillin in proprietary capsules | Ejele ...

    African Journals Online (AJOL)

    The concentration of ampicillin in ampicillin capsule preparations purchased in Owerri main market, Imo State of Nigeria, was determined using the iodometric titration method. The results showed that the ampicillin concentrations in the capsules contained between 250 and 260 mg/cap of ampicillin trihydrate. Statistical ...

  6. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the chinese silver carp,. Hypophthalmichthys molitrix (VaL). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  7. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  8. Evidence for an intact polysaccharide capsule in Bordetella pertussis.

    Science.gov (United States)

    Neo, YiLin; Li, Rui; Howe, Josephine; Hoo, Regina; Pant, Aakanksha; Ho, SiYing; Alonso, Sylvie

    2010-03-01

    Polysaccharide capsules contribute to the pathogenesis of many bacteria species by providing resistance against various defense mechanisms. The production of a capsule in Bordetella pertussis, the etiologic agent of whooping cough, has remained controversial; earlier studies reported this pathogen as a capsulated microorganism whereas the recent B. pertussis genome analysis revealed the presence of a truncated capsule locus. In this work, using transmission electron microscopy and immunostaining approaches, we provide a formal evidence for the presence of an intact microcapsule produced at the surface of both laboratory strain and clinical isolates of B. pertussis. In agreement with previous studies, we found that the capsule is optimally produced in avirulent phase. Unexpectedly, the presence of the capsule was also detected at the surface of virulent B. pertussis bacteria. Consistently, a substantial transcriptional activity of the capsule operon was detected in virulent phase, suggesting that the capsular polysaccharide may play a role during pertussis pathogenesis. In vitro assays indicated that the presence of the capsule does not affect B. pertussis adherence to mammalian cells and does not further protect the bacterium from phagocytosis, complement-mediated killing or antimicrobial peptide attack. Copyright 2009. Published by Elsevier SAS.

  9. Clinical effect of Resina Draconis capsules on primary dysmenorrhoea

    African Journals Online (AJOL)

    Clinical effect of Resina Draconis capsules on primary dysmenorrhoea. Li Sun, Jia Wang. Abstract. Purpose: To examine the effectiveness of Resina Draconis capsules in the treatment of primary dysmenorrhoea. Methods: In total, 324 patients with primary dysmenorrhoea were randomly allocated to three groups based on ...

  10. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Almeida, J.R.F. de.

    1983-01-01

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32 P from the capsule in water, with and without water flow. The desorption of residual 32 P was analysed by isotopic exchange with 31 P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32 P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31 P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author) [pt

  11. Three-dimensional simulations of Nova capsule implosion experiments

    International Nuclear Information System (INIS)

    Marinak, M.M.; Tipton, R.E.; Landen, O.L.

    1995-01-01

    Capsule implosion experiments carried out on the Nova laser are simulated with the three-dimensional HYDRA radiation hydrodynamics code. Simulations of ordered near single mode perturbations indicate that structures which evolve into round spikes can penetrate farthest into the hot spot. Bubble-shaped perturbations can burn through the capsule shell fastest, however, causing even more damage. Simulations of a capsule with multimode perturbations shows spike amplitudes evolving in good agreement with a saturation model during the deceleration phase. The presence of sizable low mode asymmetry, caused either by drive asymmetry or perturbations in the capsule shell, can dramatically affect the manner in which spikes approach the center of the hot spot. Three-dimensional coupling between the low mode shell perturbations intrinsic to Nova capsules and the drive asymmetry brings the simulated yields into closer agreement with the experimental values

  12. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  13. Protective Effect of Piper aduncum Capsule on DMBA-induced Breast Cancer in Rats.

    Science.gov (United States)

    Arroyo-Acevedo, J; Chávez-Asmat, R J; Anampa-Guzmán, A; Donaires, R; Ráez-Gonzáles, José

    2015-01-01

    The possible protective effect of Piper aduncum capsule on DMBA (dimethylbenz[α]anthracene)-induced breast cancer in rats was assessed by monitoring the tumor and lung metastases incidence and recording hematological and biochemical parameters and frequency of micronuclei. Mammary carcinogenesis was induced in 36 female Holtzman rats by providing a single subcutaneous injection of DMBA. Oral administration of P. aduncum capsule lowered adenocarcinoma and lymph node metastases incidence. Pulmonary metastasis was significantly lowered (P < 0.05). Hematological indicators showed that the triglyceride level was significantly lowered (P < 0.01) and high-density lipoprotein (HDL) level was significantly increased (P < 0.01). Also, P. aduncum capsule significantly lowered the C reactive protein (CRP) level (P < 0.01) and malondialdehyde level (P < 0.05). There was a significant decrease in the frequency of DMBA-induced micronucleated polychromatic erythrocyte (P < 0.01). Considering the antitumorigenic, hypolipidemic, anti-inflammatory, antioxidant, and antigenotoxic properties of P. aduncum capsule, we conclude that it has a protective effect on DMBA-induced breast cancer in rats.

  14. Exploding a myth: the capsule dehiscence mechanism and the function of pseudostomata in Sphagnum.

    Science.gov (United States)

    Duckett, Jeffrey G; Pressel, Silvia; P'ng, Ken M Y; Renzaglia, Karen S

    2009-01-01

    The nineteenth century air-gun explanation for explosive spore discharge in Sphagnum has never been tested experimentally. Similarly, the function of the numerous stomata ubiquitous in the capsule walls has never been investigated. Both intact and pricked Sphagnum capsules, that were allowed to dry out, all dehisced over an 8-12 h period during which time the stomatal guard cells gradually collapsed and their potassium content, measured by X-ray microanalysis in a cryoscanning electron microscope, gradually increased. By contrast, guard cell potassium fell in water-stressed Arabidopsis. The pricking experiments demonstrate that the air-gun notion for explosive spore discharge in Sphagnum is inaccurate; differential shrinkage of the capsule walls causes popping off the rigid operculum. The absence of evidence for a potassium-regulating mechanism in the stomatal guard cells and their gradual collapse before spore discharge indicates that their sole role is facilitation of sporophyte desiccation that ultimately leads to capsule dehiscence. Our novel functional data on Sphagnum, when considered in relation to bryophyte phylogeny, suggest the possibility that stomata first appeared in land plants as structures that facilitated sporophyte drying out before spore discharge and only subsequently acquired their role in the regulation of gaseous exchange.

  15. Demonstration of high coupling efficiency to Al capsule in rugby hohlraum on NIF

    Science.gov (United States)

    Ping, Y.; Smalyuk, V.; Amendt, P.; Bennett, D.; Chen, H.; Dewald, E.; Goyon, C.; Graziani, F.; Johnson, S.; Khan, S.; Landen, O.; Nikroo, A.; Pino, J.; Ralph, J.; Seugling, R.; Strozzi, D.; Tipton, R.; Tommasini, R.; Wang, M.; Loomis, E.; Merritt, E.; Montgomery, D.

    2017-10-01

    A new design of the double-shell approach predicts a high coupling efficiency from the hohlraum to the capsule, with 700 kJ in the capsule instead of 200kJ in the conventional low-Z single-shell scheme, improving prospects of double-shell performance. A recent experiment on NIF has evaluated a first step toward this goal of energy coupling using 0.7x subscale Al capsule, Au rugby hohlraum and 1MJ drive. A shell velocity of 150 μm/ns was measured, DANTE peak temperature of 255 eV was measured, and shell kinetic energy of 36 kJ was inferred using a rocket model, all close to predictions and consistent with 330kJ of total energy coupled to the capsule. Data analysis and more results from subsequent experiments will be presented. In the next step, an additional 2x increase of total coupled energy up to 700 kJ is projected for full-scale 2-MJ drive in U Rugby hohlraum. This work was performed under DOE contract DE-AC52-07NA27344.

  16. Toward an integrated model of capsule regulation in Cryptococcus neoformans.

    Directory of Open Access Journals (Sweden)

    Brian C Haynes

    2011-12-01

    Full Text Available Cryptococcus neoformans is an opportunistic fungal pathogen that causes serious human disease in immunocompromised populations. Its polysaccharide capsule is a key virulence factor which is regulated in response to growth conditions, becoming enlarged in the context of infection. We used microarray analysis of cells stimulated to form capsule over a range of growth conditions to identify a transcriptional signature associated with capsule enlargement. The signature contains 880 genes, is enriched for genes encoding known capsule regulators, and includes many uncharacterized sequences. One uncharacterized sequence encodes a novel regulator of capsule and of fungal virulence. This factor is a homolog of the yeast protein Ada2, a member of the Spt-Ada-Gcn5 Acetyltransferase (SAGA complex that regulates transcription of stress response genes via histone acetylation. Consistent with this homology, the C. neoformans null mutant exhibits reduced histone H3 lysine 9 acetylation. It is also defective in response to a variety of stress conditions, demonstrating phenotypes that overlap with, but are not identical to, those of other fungi with altered SAGA complexes. The mutant also exhibits significant defects in sexual development and virulence. To establish the role of Ada2 in the broader network of capsule regulation we performed RNA-Seq on strains lacking either Ada2 or one of two other capsule regulators: Cir1 and Nrg1. Analysis of the results suggested that Ada2 functions downstream of both Cir1 and Nrg1 via components of the high osmolarity glycerol (HOG pathway. To identify direct targets of Ada2, we performed ChIP-Seq analysis of histone acetylation in the Ada2 null mutant. These studies supported the role of Ada2 in the direct regulation of capsule and mating responses and suggested that it may also play a direct role in regulating capsule-independent antiphagocytic virulence factors. These results validate our experimental approach to dissecting

  17. Photophysics Applied to Cavitands and Capsules.

    Science.gov (United States)

    Berryman, Orion B; Dube, Henry; Rebek, Julius

    2011-07-01

    The use of light as a stimulus to control functional materials or nano-devices is appealing as it provides convenient control of triggering events where and when they are desired without introducing extra components to the system. Many photophysical and photochemical processes are extremely fast, giving rise to nearly instantaneous onset of events. However, these fast processes can be challenging to engineer into chemical systems. Supramolecular chemistry offers a convenient way to study and control photoprocesses. Given the reversible and self-programmed nature of modern host-guest systems, a modular approach can be considered in which different photoprocesses are coupled to obtain complex functions that emerge and are controlled solely by light inputs. In this review, we highlight recent examples of photoswitching and photophysics applied in the context of supramolecular host-guest systems, with a particular emphasis on resorcinarene based cavitands and hydrogen bonded capsules.

  18. Capsule HRB-15B postirradiation examination report

    International Nuclear Information System (INIS)

    Ketterer, J.W.; Bullock, R.E.

    1981-06-01

    Capsule HRB-15B design tested 184 thin graphite trays containing unbonded fuel particles to peak exposures of 6.6 x 10 25 n/m 2 (E > 29 fJ)/sub HTGR/ fast fluence, approx. 27% fissions per initial metal atom (FIMA) fissile burnup, and 6% FIMA fertile burnup at nominal time-averaged temperatures of 815 to 915 0 C. The capsule tested a variety of low-enriched uranium (approx. 19.5% U-235) fissile particle types, including UC 2 , UC/sub x/O/sub y/, UO 2 , zirconium-buffered UO 2 (referred to in this report as UO 2 /sup *), and 1:1(Th,U)O 2 with both TRISO and silicon-BISO coatings. All fertile particles were ThO 2 with BISO, silicon-BISO, or TRISO coatings. The findings indicated that all TRISO particles retained virtually all of their fission product inventories, except small quantities of silver, at these irradiation temperatures, while some of the silicon-BISO particles released significant amounts of both silver and cesium. No kernel migration, pressure vessel, or outer pyrolytic carbon (OPyC) failures were observed in the fuel particles, which had total diameters of 2 /sup */ particles exhibited no detrimental irradiation effects, but they contained pure carbon precipitates in the kernels after irradiation which were not observed in the undoped UO 2 particles. Postirradiation examination revealed no differences in the irradiation performance of three UC/sub x/O/sub y/ kernel types with varying oxygen/uranium ratios

  19. Clinical evaluation of arthroscopic treatment of shoulder adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the results of arthroscopic releases performed in patients with adhesive capsulitis refractory to conservative treatment. METHODS: This was a retrospective study, conducted between 1996 and 2012, which included 56 shoulders (52 patients that underwent surgery; 38 were female, and 28 had the dominant side affected. The mean age was 51 (29-73 years. The mean follow-up was 65 (12-168 months and the mean preoperative time was 8.9 (2-24 months. According to Zukermann's classification, 23 cases were considered primary and 33 secondary. With the patient in the lateral decubitus position, circumferential release of the joint capsule was performed: joint debridement; rotator interval opening; coracohumeral ligament release; anterior, posterior, inferior, and finally antero-inferior capsulotomy. A subscapularis tenotomy was performed when necessary. All patients underwent intense physical therapy in the immediate postoperative period. In 33 shoulders, an interscalene catheter was implanted for anesthetic infusion. Functional results were evaluated by the UCLA criteria. RESULTS: Improved range of motion was observed: mean increase of 45° of elevation, 41° of external rotation and eight vertebral levels of medial rotation. According to the UCLA score excellent results were obtained in 25 (45% patients; good, in 24 (45%; fair, in two (3%; and poor, in two (7%. Patients who had undergone inferior capsulotomy achieved better results. Only 8.8% of patients who used the anesthetic infusion catheter underwent postoperative manipulation. Seven patients had complications. CONCLUSION: There was improvement in pain and range of motion. Inferior capsulotomy leads to better results. The use of the interscalene infusion catheter reduces the number of re-approaches.

  20. Clinical Efficacy of Proton Pump Inhibitor versus Prompt Endoscopy for Management of People with Dyspepsia

    DEFF Research Database (Denmark)

    Kjeldsen, Hans Christian; Lauritzen, Torsten; Christensen, Bo

      Title:   Clinical Efficacy of Proton Pump Inhibitor versus Prompt Endoscopy for Management of People with Dyspepsia: A Randomized Clinical Trial in General Practice.     Purpose: To compare the clinical efficacy of two strategies for management of dyspepsia in general practice in a RCT design.......   Setting: June 2000 to August 2002, 41 GPs, Aarhus County, Denmark   Methods: 368 people with dyspepsia (epigastric pain/discomfort, no alarm symptoms) were randomly assigned to treatment with omeprazol 40 mg/day for two weeks (PPI group, n:185) or endoscopy (endoscopy group, n:183). Due to migration......, dyspeptic contacts to GP or patients' satisfaction. Conclusions: Prompt endoscopy was superior to proton pump inhibitor concerning symptom improvement in management of dyspepsia in general practice when pain/discomfort was the primary symptom. There were no differences between the two strategies in respect...