WorldWideScience

Sample records for capillary fine needle

  1. A convenient tool for gas derivatization using fine-needle capillary mounting for protein crystals

    International Nuclear Information System (INIS)

    Mizuno, Nobuhiro; Makino, Masatomo; Kumasaka, Takashi

    2013-01-01

    A convenient gas-derivatization tool for protein crystals is presented in combination with a fine-needle capillary and a gas-pressure regulator. Gas derivatization of protein crystals is useful not only to analyse gas-binding proteins but also to solve the phase problem of X-ray crystallography by using noble gases. However, the gas pressurization tools for these experiments are often elaborate and need to release the gas before flash-cooling. To simplify this step, a procedure using a fine-needle capillary to mount and flash-cool protein crystals under the pressurization of gases has been developed. After the crystals are picked up with the capillary, the capillary is sealed with an adhesive and then connected directly to a gas regulator. The quality of the diffraction data using this method is comparable with that of data from conventional pressurization procedures. The preparation of xenon-derivatives of hen egg-white lysozyme using this method was a success. In the derivatives, two new xenon binding sites were found and one of their sites vanished by releasing the gas. This observation shows the availability of flash-cooling under gas pressurization. This procedure is simple and useful for preparing gas-derivative crystals

  2. Capillary Versus Aspiration Biopsy: Effect of Needle Size and Length on the Cytopathological Specimen Quality

    International Nuclear Information System (INIS)

    Hopper, Kenneth D.; Grenko, Ronald T.; Fisher, Alicia I.; TenHave, Thomas R.

    1996-01-01

    Purpose: To test the value of the nonaspiration, or capillary, biopsy technique by experimental comparison with the conventional fine-needle aspiration technique using various needle gauges and lengths. Methods: On fresh hepatic and renal tissue from five autopsies, multiple biopsy specimens were taken with 20, 22, and 23-gauge Chiba needles of 5, 10, 15, and 20-cm length, using the aspiration technique and the capillary technique. The resultant specimens were graded on the basis of a grading scheme by a cytopathologist who was blinded to the biopsy technique. Results: The capillary technique obtained less background blood or clot which could obscure diagnostic tissue, although not significantly different from the aspiration technique (p= 0.2). However, for the amount of cellular material obtained, retention of appropriate architecture, and mean score, the capillary technique performed statistically worse than aspiration biopsy (p < 0.01). In addition, with decreasing needle caliber (increasing needle gauge) and increasing length, the capillary biopsy was inferior to the aspiration biopsy. Conclusion: The capillary biopsy technique is inferior to the aspiration technique according to our study. When the capillary technique is to be applied, preference should be given to larger caliber, shorter needles

  3. Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hongming Song

    2015-01-01

    Full Text Available Background. Fine needle aspiration cytology (FNAC and fine needle nonaspiration cytology (FNNAC are useful cost-effective techniques for preoperatively assessing thyroid lesions. Both techniques have advantages and disadvantages, and there is controversy over which method is superior. This meta-analysis was performed to evaluate the differences between FNAC and FNNAC for diagnosis of thyroid nodules. Methods. Primary publications were independently collected by two reviewers from PubMed, Web of Science, Google Scholar, EBSCO, OALib, and the Cochrane Library databases. The following search terms were used: fine needle, aspiration, capillary, nonaspiration, sampling without aspiration, thyroid, and cytology. The last search was performed on February 1, 2015. Results. Sixteen studies comprising 1,842 patients and 2,221 samples were included in this study. No statistically significant difference was observed between FNAC and FNNAC groups with respect to diagnostically inadequate smears, diagnostically superior smears, diagnostic performance (accuracy, sensitivity, specificity, negative predictive value, and positive predictive value, area under the summary receiver operating characteristic curve, average score of each parameter (background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture, and total score of five parameters. Conclusion. FNAC and FNNAC are equally useful in assessing thyroid nodules.

  4. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  5. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  6. Fine needle aspiration cytology of cervicofacial actinomycosis

    Directory of Open Access Journals (Sweden)

    Venkatesh Kusuma

    2008-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Cervicofacial actinomycosis presenting as a fixed jaw swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of cervicofacial actinomycosis diagnosed by fine needle aspiration, along with a review of the relevant literature. A 60 year-old man presented with a gradually increasing 6 x 5 cm swelling in the left side of his jaw. The swelling was fixed, without any apparent sinus or abscess. Fine needle aspiration was diagnostic as it revealed colonies of actinomyces surrounded by polymorphs and chronic inflammatory cells. The histopathological study of the excised specimen confirmed the cytological findings. Fine needle aspiration is an effective tool in the diagnosis of actinomycosis although its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the fine needle aspiration technique.

  7. Discordance Rate between Thyroid Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    Discordance Rate between Thyroid Fine Needle Aspiration Cytology and Histopathologic Diagnosis. Wondwossen Ergete, Daniel Abebe. Abstract. Fine Needle Aspiration (FNA) of the thyroid is a low cost procedure, which can give an accurate diagnosis promptly. The objective of this study was to assess the diagnostic ...

  8. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  9. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  10. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  11. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  12. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  13. Fine needle diagnosis in lumbar osteomyelitis

    International Nuclear Information System (INIS)

    Joshi, K.B.; Brinker, R.A.

    1983-01-01

    Lumbar vertebral body and disk infection, presenting as low back pain, is a relatively uncommon disease but is seen more often in drug addicts. Radiographs show typical changes of infection of the lumbar vertebrae and adjacent disc. Under local anesthesia a fine needle is placed, saline injected, and aspirated. The entire needle-syringe unit is submitted to the bacteriology department. Pseudomonas infection is usually found. This method of diagnosis is simple, cost effective, well accepted by the patients, and can be done on outpatients. (orig.)

  14. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    Science.gov (United States)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  15. Extrapulmonary tuberculosis: Fine needle aspiration cytology ...

    African Journals Online (AJOL)

    Patients and Methods: This is a consecutive 9-year analysis of patients with peripheral lymphadenopathy. All the patients had fine needle aspiration. Smears were made, fixed in 95% alcohol and stained with hematoxylin and eosin and Zeihl Neelsen stains. Results: 48 patients, 31 males and 17 females, were analyzed.

  16. Diagnosis Of Thyroid Enlargement: Use Of Fine Needle Aspiration ...

    African Journals Online (AJOL)

    One hundred and ten Fine Needle Aspiration Biopsies (FNAC) obtained from 87 patients with thyroid enlargement or nodules were retrospectively reviewed. Aspiration biopsy was accomplished using 21-gauge needle attached with 20-ml plastic syringe. There were 14 males and 73 females involved in the study. Sixty- four ...

  17. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen

    International Nuclear Information System (INIS)

    O'Connell, A.M.; Keeling, F.; Given, M.; Logan, M.; Lee, M.J.

    2008-01-01

    Historically, fine-needle aspiration cytology (FNAC) has varying sensitivity, specificity and accuracy in the diagnosis of abdominal lesions with a high insufficient sampling rate. We compared 20-G fine-needle trucut biopsy (FNTB) with FNAC results in the biopsy of solid abdominal tumours. A retrospective review of 171 (128x 20-G FNTB and 43x FNAC) ultrasound-guided biopsies of abdominal tumours on 157 patients (male : female 85:72, mean age 61.25 years) were carried out. One hundred and seventy-one biopsies were carried out: liver 109, pancreas 19, lumph node 10, omentum 5, right iliac fossa mass 6, adrenal 6 and others 16. An average of 2.06 and 1.97 passes (range 1-4) were carried out per FNTB and FNAC, respectively. A definitive diagnosis was made in 122/128 biopsies (95.3%) and 32/43 biopsies (74.4%) for FNTB and FNAC, respectively. Diagnoses consisted of metastatic liver disease (74/171), pancreatic adenocarcinoma (10/171), lymphoma (8/171) and others (33/171) and benign (29/171). No significant complications occurred in either group. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87, 100, 100, 50, 84.4 and 93.1, 100, 100, 60, 71.4 for FNTB and FNAC, respectively. A greater and more consistent positive diagnosis rate is yielded by 20-G FNTB (95.3%) that FNAC (74.4%). The diagnostic accuracy of FNTB is 84.4% cmopared with 69.8% for FNAC. A greater insufficient sampling rate occurs with FNAC (25.6%) than with FNTB (4.7%). For abdominal biopsy, 20-G FNTB needles have a much higher yield than FNAC with no increase in complications. FNTB is the preferred choice, particularly where cytological assistance at the time of biopsy is unavailable.

  18. Extramedullary plasmacytoma. Fine needle aspiration findings.

    Science.gov (United States)

    Kumar, P V; Owji, S M; Talei, A R; Malekhusseini, S A

    1997-01-01

    To determine the role of fine needle aspiration cytology in the diagnosis of extramedullary plasmacytoma. The study group consisted of 13 patients with palpable masses at various sites. The tumors were aspirated for cytologic study. The smears revealed groups of mature and immature plasma cells at various stages of maturation. Mature plasma cells showed an eccentric nucleus and abundant, deep, basophilic cytoplasm with a paranuclear halo. Plasmablasts (immature plasma cells) showed a prominent, eccentric nucleus with single, large nucleolus and abundant, deep, basophilic cytoplasm with no paranuclear halo. Binucleate and multinucleate forms were also seen quite often. The tumors were excised, and the histologic sections confirmed the cytologic diagnosis. All the patients received radiotherapy. One patient (18 years old) developed recurrence and died due to extensive infiltration into the maxilla and mandible. Two patients (57 and 62 years) developed multiple myeloma one to two years after the excision of tumors, and both died two to three months later. The remaining 10 patients were alive and well at this writing. The smears from all 13 patients were diagnosed as extramedullary plasmacytomas by fine needle aspiration cytology.

  19. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  20. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    Science.gov (United States)

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  1. Fine-needle versus core-needle biopsy – which one to choose in preoperative assessment of focal lesions in the breasts? Literature review

    Directory of Open Access Journals (Sweden)

    Ewa Łukasiewicz

    2017-12-01

    Full Text Available Aim: The aim of the study was to review two techniques that can be used to verify focal lesions in the breasts: fine-needle aspiration biopsy and core-needle biopsy. Material and methods: Fifty-five articles (original papers and reviews, half of them published within the past 5 years, were included in the analysis. The authors also took their own experience into account. Results: Pre-operative assessment of focal lesions in the breasts is crucial in the planning of further therapeutic management. The role of fine-needle aspiration biopsy has been reduced lately due to its low sensitivity and specificity as well as a high rate of non-diagnostic, suspicious and false negative results. This method does not enable one to differentiate between in situ and invasive disease. Currently, fine-needle biopsy is recommended for cystic lesions, suspected of being recurrences in the chest wall, and lymph node metastases. Core-needle biopsy is the basic diagnostic method of breast lesions. According to the recommendations of the Polish Ultrasound Society and American College of Radiology, BIRADS 4 and 5 lesions should be evaluated histopathologically. Core-needle biopsy makes it possible to establish a final diagnosis more frequently than fine-needle biopsy, both in the case of benign and malignant lesions. It delivers more information about the nature of a tumor (mutation of HER-2, estrogen and progesterone receptors and Ki-67 index. Its limitations include: underestimation of invasion and failure to recognize the components of ductal carcinoma in situ in papillary and atypical lesions. Single fine-needle aspiration biopsy is inexpensive, but when considering the cost of further diagnosis due to non-diagnostic, suspicious and atypical results, this method generates high additional costs. Conclusions: Microscopic verification of focal breast lesions is crucial for further therapeutic decisions. It has been proven that histopathological verification is more

  2. Fine needle aspiration cytology of parapharyngeal tumors

    Directory of Open Access Journals (Sweden)

    Mondal Palash

    2009-01-01

    Full Text Available Background: Parapharyngeal tumors are rare and often pose diagnostic difficulties due to their location and plethora of presentations. Objectives: The study was undertaken to study the occurrence in the population and to evaluate the exact nature by fine needle aspiration cytology (FNAC. Materials and Methods: A total of five hundred and six cases of lateral neck lesions were studied over three and half years. Of these 56 suspected parapharyngeal masses were selected by clinical and radiological methods. Cytopathology evaluation was done by fine needle aspiration cytology with computed tomography and ultrasonography guidance wherever necessary. Histopathology confirmation was available in all the cases. Results: On FNAC diagnosis could be established in 54 cases while in two cases the material was insufficient to establish a diagnosis. The tumors encountered were, pleomorphic adenoma (33, schwannoma (3, neurofibroma (11, paraganglioma (5, angiofibroma (1 and adenoid cystic carcinoma (1. Four false positives and two false negative cases were encountered. Overall sensitivity was 96%, with specificity of 99% and accuracy being 98.8%. Conclusions: With proper clinical and radiological assessment, FNAC can be extremely useful in diagnosing most of these lesions except a few which need histopathological and even immunohistochemical confirmation.

  3. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  4. Fine needle aspiration cytology of breast lumps with histopathologic ...

    African Journals Online (AJOL)

    diagnosis of palpable breast lesions, in recent years two types of minimally invasive .... negative predictive value of FNAC as a diagnostic pro- cedure for the entire ... The earliest large scale use of Fine Needle aspiration. Cytology FNAC as a ...

  5. Diagnostic accuracy of fine needle aspiration cytology in patients ...

    African Journals Online (AJOL)

    Objective: To estimate the sensitivity and specificity of FNAC in detecting malignancy for thyroid disease using histopathology ... thyroid carcinoma being the most predominant type and colloid goiter was the most predominant benign thyroid disease. The sensitivity ..... tic accuracy of fine needle aspiration cytology in thyroid.

  6. Thyroid fine-needle aspiration and the bethesda classification system

    DEFF Research Database (Denmark)

    Larsen, Louise Vølund; Egset, Alice Viktoria; Holm, Camilla

    2018-01-01

    INTRODUCTION: Fine-needle aspiration (FNA) is a cornerstone in diagnosing thyroid nodules. For decades, Danish FNA have been categorised into the groups: “FNA not per-formed”, “Inadequate”, “Cystic”, “Inconclusive”, “Benign”, “Suspicious”, “Malignant” and “Information missing”. Internationally...

  7. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    Science.gov (United States)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  8. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  9. Free thyroxine in needle washout after fine needle aspiration biopsy of toxic thyroid nodules.

    Science.gov (United States)

    Raikov, Nikolai; Nonchev, Boyan; Chaushev, Borislav; Vjagova, Diyana; Todorov, Svetoslav; Bocheva, Yana; Malceva, Daniela; Vicheva, Snejinka; Raikova, Asyia; Argatska, Antoaneta; Raikov, Miroslav

    2016-01-01

    The main diagnostic tool for toxic adenomas (TA) is radionuclide imaging indicated in patients with evidence of thyroid nodules in combination with thyrotoxic syndrome. Thyroid ultrasound and fine-needle aspiration biopsy (FNAB) are widely used for the valuation of thyroid masses. There is no literature data concerning the utility of FNAB and related tests for the diagnosis of hyperfunctioning thyroid nodules. The purpose of this study is to determine the levels of free thyroxine (FT4) in the needle washout after FNAB of hot thyroid nodules. The results of our study show that the FT4 levels in needle washout from TA were significantly higher than the surrounding parenchyma and correlated with the hormonal changes in patients with thyroid hyperfunctioning nodules. Further studies on a large number of patients are needed to refine the diagnostic value of this method and evaluate its importance in quantitative risk assessment of thyroid autonomy.

  10. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  11. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  12. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    Science.gov (United States)

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  13. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  14. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  15. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  16. a pilot study of the diagnostic accuracy of fine needle aspirate cytol

    African Journals Online (AJOL)

    2018-06-02

    Jun 2, 2018 ... Fibroadenoma of the breast in a South African population -a pilot study of the ... Keywords: Fibroadenoma, diagnosis, breast ultrasonography, fine needle ..... breast cancer among Sudanese patients with breast palpa-.

  17. Fine-needle cytology of breast lesions seen on mammograms

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Ridlen, M.S.; Dowlatshahi, K.; Jokich, P.M.; Bibbo, M.

    1989-01-01

    Stereotactic fine-needle aspiration of nonpalpable breast lesions is operator dependent. The authors have analyzed 250 biopsies at our institution (comparing aspiration cytology with surgical biopsy) for sensitivity, false-negative, and insufficient-sample rates of three different interpreters. Needle aspiration as an alternative to biopsy or a follow-up for lesions of low mammographic suspicion would have resulted in detection of most, but not all, cancers. Over 40 additional biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies for low-suspicion lesions could be avoided. Aspiration cytologic series should report separately insufficient samples and LCIS, and should use a consistent threshold for interpreting cytologic results

  18. Comparison of specimen adequacy in fine needle aspiration cytology performed with different gauge needles in palpable external swellings

    International Nuclear Information System (INIS)

    Sarfraz, T.; Bashir, S.; Tariq, H.; Malik, T.M.

    2013-01-01

    Background: Fine Needle Aspiration Cytology (FNAC) of external swellings may yield different specimen adequacy depending on different gauge needles used for aspiration. Objective: To compare the specimen adequacy aspirated by various gauge (21 and 22) needles in external palpable swellings of lymph nodes, thyroid gland, salivary glands, breast and soft tissue. Study Design: Comparative cross sectional study. Duration: Six months (1st Jan 2012 to 30th June 2012). Setting: Histopathology/Cytology department Combined Military Hospital Peshawar (Pakistan). Methodology: This was a prospective study of 200 cases in which FNAC was performed with either 21 or 22 gauge needles (100 cases with 21 gauge and 100 with 22 gauge needles). Equal number of aspirations were done with 21 and 22 gauge needles from the swellings of thyroid gland, lymph nodes, salivary glands, breast and soft tissue. Results were analyzed for specimen adequacy by using SPSS 17. Results: A total number of 200 cases were recruited in this study, out of which 100 were aspirated with 21 gauge needles and 100 with 22 gauge needles. Specimen adequacy in swellings of thyroid, lymph nodes and salivary glands was better with 22 gauge amounting 90%, 80% and 80% respectively, as compared to yield with 21 gauge needles which was 85%, 70% and 60% respectively. On the other hand in swellings of breast and soft tissue, the specimen adequacy was better with 21 gauge needles giving 98% and 90 % adequate yield respectively as compared to 22 gauge needles which was 70% and 40 % respectively. Conclusion: Needles of smaller gauge (22 gauge) give a better yield in swellings of thyroid, lymph nodes and salivary gland while in swellings of breast and soft tissue sample adequacy is better with larger gauge needle (21 gauge). (author)

  19. Fine needle aspiration cytology versus frozen section in branchial cleft cysts.

    Science.gov (United States)

    Begbie, F; Visvanathan, V; Clark, L J

    2015-02-01

    Branchial cleft cysts occur because of a failure of involution of the second branchial cleft. However, as well-differentiated squamous cell carcinoma can mimic branchial cleft cysts, there is a lack of consensus on the appropriate management of cystic neck lumps. To report our experience of fine needle aspiration cytology and frozen section examination in the management of cystic neck lumps. Retrospective case note review of patients managed in the Southern General Hospital, Scotland, UK. The sensitivity of fine needle aspiration cytology and frozen section for detecting branchial cleft cysts was 75 per cent and 100 per cent respectively. Two patients who did not undergo intra-operative frozen section examination were either over- or under-treated, which is discussed. Adult patients subjected to surgical excision of a suspected branchial cyst should undergo intra-operative frozen section analysis regardless of clinical suspicion for malignancy. This part of management is critical to ensure patients are offered appropriate treatment.

  20. Quantitative analysis of fine needle aspiration biopsy samples

    International Nuclear Information System (INIS)

    Rajer, M.; Kmet, M.

    2005-01-01

    Background. The fine needle aspiration biopsy (FNAB) is one of the methods used in tumour evaluation. Since a certain number of tumour cells are needed for a complete diagnostic algorithm, we wanted to test how many cells remain in the needle and syringe after routine stains have been made and which factors influence this number. The remaining cells are used in ancillary diagnostic procedures. Materials and methods. One hundred fifty two FNAB samples of tumours of the breast, thyroid and lymph nodes were included in our study. We counted the cells which were left in the needle and the syringe after the standard smears had been made. Buerker-Tuerk's chamber was used for this purpose. Results. The number of cells depended on the organ from which the cells had been aspirated, on the type of tumour and, in the case of breast cancer, also on the level of experience of the FNAB performer. The percentage of samples with too few cells for all modern diagnostic methods (<5x105 ) is lowest in FNAB of lymph nodes (4.9%), followed by breast (16.7%) and thyroid (18%). Conclusions. We concluded that FNAB in the majority of cases grants a sufficient number of cells for the standard microscopic evaluation and also ancillary diagnostic procedures. (author)

  1. Fine needle aspiration biopsy of pancreas. Cytological assessment

    International Nuclear Information System (INIS)

    Coufal, L.; Heger, L.

    1987-01-01

    The benefits are presented of cytological examination of bioptical material from the pancreas using computerized tomography (CT) or ultrasound. The case is presented of one patient who had repeatedly undergone endoscopy with no results. Only cytological examination of material sampled using fine needle aspiration under CT control helped to immediately diagnose the process. The cytological finding correlated with the histological examination of material later taken during surgery. The problems are discussed of the differential diagnosis of tumors of the pancreas. (author). 5 figs., 9 refs

  2. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  3. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  4. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  5. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  6. Stereotaxic Fine-Needle Aspiration Cytologic Evaluation of Non-palpable Breast Lesions

    Directory of Open Access Journals (Sweden)

    M Haghighi

    2005-07-01

    Full Text Available Background: Although long-term mammography is the standard means of evaluation for the probably benign lesions of breast, some times we feel obliged to know about the benignity and the extent of lesions earlier. Therefore we evaluated the diagnostic value of stereotaxic fine-needle aspiration (SFNA in low suspicion breast lesions as an alternative to the routine modality. Methods: The study included 150 low-suspicion or probably benign breast lesions detected on mammography. All cases underwent SFNA and followed by exciosional biopsy or follow-up mammography based on SFNA findings. Results: Fibroadenoma and normal tissue lesions were diagnosed in 57% of patients, in whom no evidence of malignancy was found in the follow-up period. In 48 patients with cytologic findings suggestive of proliferative fibrocystic disease, three cases of malignancy were detected by excisional biopsy. Conclusion: A SFNA result suggesting benignity allows safe clinical follow-up, whereas a suspicious or equivocal diagnosis needs more invasive modalities for further investigations. Key words: Breast, Mammography, Stereotaxic, Fine-Needle Aspiration (FNA

  7. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  8. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  9. Selective fine needle aspiration of parotid masses. FNA should be performed in all patients older than 60 years.

    LENUS (Irish Health Repository)

    Kieran, S M

    2012-02-01

    OBJECTIVES: The exact role of fine needle aspiration in the pre-operative assessment of patients presenting with parotid masses is controversial. Some surgeons propose that fine needle aspiration be performed only selectively in those patients with likely malignant disease, whilst others recommend it for all patients presenting with such a mass. Intuitively, one would expect older patients to be more likely to suffer from primary malignant parotid tumours and secondary deposits of malignant skin tumours. Therefore, we hypothesised that older patients with a parotid mass should undergo fine needle aspiration regardless of their medical history. DESIGN: We retrospectively reviewed 197 consecutive parotidectomies to test this hypothesis. RESULTS: One hundred and twenty-one patients (61.4 per cent) were diagnosed with benign disease, whilst 76 (38.6 per cent) were diagnosed with malignant disease. Eighty-three per cent of patients aged 60 years or younger had benign disease, as opposed to 35.6 per cent of patients aged more than 60 years. Malignant disease occurred more commonly in patients older than 60 years (odds ratio 8.962, 95 per cent confidence interval 4.607-17.434). CONCLUSION: In patients with a parotid mass, fine needle aspiration should be performed on all those aged 60 years or older.

  10. Diagnostic accuracy of fine needle aspiration cytology in hepatic tumours

    International Nuclear Information System (INIS)

    Nazir, R.T.; Sharif, M.A.; Iqbal, M.; Amin, M.S.

    2010-01-01

    To determine the diagnostic accuracy of fine-needle aspiration cytology (FNAC) in liver masses to isolate malignant from benign tumours and hepatocellular carcinoma (HCC) from metastatic tumours. Study Design: Cross-sectional, observational. Place and Duration of Study: Department of Histopathology, Combined Military Hospital, Peshawar, from June 2004 to June 2005. Methodology: All the patients with liver masses confirmed by ultrasonography, irrespective of age and gender, were included. Patients with inflammatory lesions were excluded from the study. Selected patients underwent fine-needle aspiration under ultrasound guidance followed by needle biopsy. The cytological slides were stained by haematoxylin and eosin (H and E) stain, while Papanicolaou's stain was employed in selective cases. Needle biopsy fragments were fixed in formalin followed by paraffin embedding and staining with H and E stain. Sensitivity and specificity of FNAC in the diagnosis of liver masses was determined using histological diagnosis on liver biopsy as gold standard. Results: There were one hundred subjects. The mean age at presentation was 55 +- 12 years with male to female ratio of 1.7:1. Cytological diagnosis in 19 cases was benign/non-neoplastic and 81 was malignant. Out of the latter, 49 (60.49%) were HCC and 32 (39.51%) were metastatic tumours on cytology. The overall sensitivity, specificity and accuracy of FNAC in the diagnosis of malignant lesions was 95.2%, 100% and 96% respectively using histological diagnosis on liver biopsy as gold standard. Sensitivity of FNAC to differentiate HCC from metastatic tumours in liver was 96% while specificity was 100% having a diagnostic accuracy of 97.5%. The discrepancy in cyto-histological comparison was mainly seen in well differentiated and poorly-differentiated HCCs. Conclusion: FNAC of the liver masses is a simple, safe, accurate, economical screening test without significant morbidity that can be used to identify the vast majority of

  11. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    Science.gov (United States)

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  12. A technique to improve diagnostic information from fine-needle aspirations: immunohistochemistry on cytoscrape

    DEFF Research Database (Denmark)

    Skov, Birgit Guldhammer; Kiss, Katalin; Ramsted, Julie

    2009-01-01

    BACKGROUND: Cytologic examination of fine-needle aspiration (FNA) material is being used increasingly for the diagnosis of pulmonary lesions. Accurate distinction between nonsmall cell lung cancer (NSCLC), including subgroups, and small cell lung cancer and between primary lung cancer and metasta...

  13. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  14. Metastatic Chordoma: A Diagnostic Challenge on Fine Needle Aspiration

    Directory of Open Access Journals (Sweden)

    Ghassan Tranesh

    2016-01-01

    Full Text Available Chordomas are primary low grade malignant tumors of bone that usually arise within both ends of axial skeleton. The Notochord is a midline, ectoderm-derived structure that defines the phylum of chordates. Chordomas may pose difficult diagnostic challenges when encountered in secondary locations, such as lungs or other parenchymatous organs. We report the cytologic findings of a metastatic chordoma sampled through CT-scan guided fine needle aspiration (FNA of lower lobe lung nodule in a 54-year-old man diagnosed with recurrent chordoma involving the lumber spine and paraspinal region.

  15. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  16. Risk of malignancy in fine-needle aspiration biopsy in patients with thyroid nodules

    DEFF Research Database (Denmark)

    Egset, Alice Viktoria; Holm, Camilla; Larsen, Stine Rosenkilde

    2017-01-01

    Introduction: Fine-needle aspiration biopsy (FNAB) is the cornerstone of thyroid nodule evaluation. In most cases, FNAB can discriminate between benign and malignant disease. In other cases, it is only indicative of malignancy and the results are considered “suspicious”. In Denmark, thyroid FNAB...

  17. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  18. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  19. Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions

    International Nuclear Information System (INIS)

    Ahmed, M.E.; Ahmad, I.

    2010-01-01

    Background: Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. Methods: The study was conducted prospectively at Department of Radiology, Shaukat Khanum Memorial Cancer Hospital and Research Centre, Pakistan from March 2004 to February 2005. All the patients underwent fine needle aspiration cytology and core biopsy. Later on, all of them had excision biopsy/ mastectomy. Prospectively 80 patients were studied; information was collected on a specifically designed form according to inclusion criteria. The patient age, sex, medical record number and side of lesion were recorded. Clinical history of duration of lump was also taken. Informed consent was obtained. Results: The age of patients were ranges from 20-71 years, with mean of 44.31+- 11.002 and the maximum number of patients 28 (35.3%) was between the ages 50 - 59 years. The sensitivity of FNAC was 92.85%, while the specificity of was 90% and the accuracy rate was 92.1%. The sensitivity of core biopsy was 94.64%, specificity 91.30% and accuracy rate was 94.87%. Conclusion: Fine Needle Aspiration has been found to be an extremely useful method for the diagnosis of lumps of breast. The accuracy and the sensitivity of diagnosis on fine needle aspiration cytology were high. (author)

  20. Conclusiveness of fine needle aspiration in 2419 histologically confirmed benign and malignant breast lesions

    NARCIS (Netherlands)

    Kooistra, B.; Wauters, C.; Wobbes, T.; Strobbe, L.

    2011-01-01

    We aimed to retrospectively assess (1) the conclusiveness of breast fine needle aspiration (FNA) in a histologically confirmed population and (2) the clinical and radiologic determinants of a conclusive diagnosis. Aspirates were diagnosed as inadequate, benign, atypical, suspicious or malignant. We

  1. Experimental study on venography with carbon dioxide by fine-needle direct-puncture of abdominal viscera

    International Nuclear Information System (INIS)

    Zhu Chi; Xu Changliang; Zhang Dezhi; Zheng Feiqun; Sheng Qiang; Zhang Xiuze; Xiong Zhuang; Yu Yongqiang

    2005-01-01

    Objective: To evaluate the feasibility and safety of CO 2 venography by fine-needle direct-puncture of abdominal viscera. Methods: Two healthy female pigs and two healthy female dogs were used in this study. Multi-point punctures of abdominal viscera including liver, spleen, kidney, pancreas, walls of small intestines, and uterus with 25-gauge needle were performed for CO 2 venography in all animals. Diagnostic image quality of the angiographic images was assessed by 3 independent observers. Results: Splenic-portal vein, hepatic vein, portal vein, renal vein and inferior vena cava, uterine vein and ovarian vein could be visualized by fine needle direct CO 2 injection into the related organic parenchyma, while draining vein of small intestines and pancreas could not be shown. Splenic-portal veins were revealed especially well with grade A of 87.5% (7/8) , grade B of 12.5% (1/8), and grade C of 0%. The image quality of hepatic veins were 81.8% (9/11), 18.2% (2/11), and 0% for grade A, B, and C, respectively. The portal veins were 77.8% (7/9), 22.2%(2/9), and 0% for grade A, B, and C, respectively. The renal vein and inferior vena cava were 38.5% (5/13), 61.5% (8/13), and 0% for grade A, B, and C respectively. The uterine veins and ovarian veins were 0%, 33.3% (2/6), and 66.7% (4/6) for grade A, B, and C, respectively. During the CO 2 angiographic procedure, vital signs remained stable in all animals. Conclusion: CO 2 venography with fine-needle direct-puncture of abdominal viscera, excluding small intestines and pancreas, is feasible and safe. (authors)

  2. Ultrasonography-Guided Fine Needle Aspiration Cytology of Cervical Lymphadenopathy: Comparative Study of the Cytological Adequacy Using of 21- and 23- Gauge Needles

    International Nuclear Information System (INIS)

    Beak, Jin Wook; KIm, Dong Wook; Kim, Bo Mi

    2011-01-01

    To assess the difference in the cytological adequacy of ultrasonography (US)-guided fine needle aspiration cytology (US-FNAC) for cervical lymphadenopathy using 21 and 23 gauge needles. US-FNACs were separately performed on two cervical lymph nodes and in each patient using 21 gauge (group A) and 23 gauge (group B) needles, respectively. We used 4 grade classifications for the cytological analysis of each slide and compared the cytological adequacy of US-FNAC for cervical lymphadenopathy in the two groups. We performed US-FNACs on 58 cervical lymph nodes from 29 patients, with a cytological adequacy of 69.0%. The number of adequate cytological results was 19 (65.5%) in group A and 21 (72.4%) in group B, and the diagnostic adequacy did not differ significantly between the two groups (Mann-Whitney test, p = 0.574). There was no statistically significant difference in the cytological adequacy of US-FNAC for cervical lymphadenopathy according using of 21 and 23 gauge needles.

  3. Cytomorphology of nipple discharge and fine needle aspiration of duct papilloma

    Directory of Open Access Journals (Sweden)

    H B Bannur

    2012-01-01

    Full Text Available The primary role of fine needle aspiration (FNA of the breast is the distinction between benign and malignant lesions; but in many cases, additional information may be obtained. The major breast lesions that yield papillary fragments on FNA are papillary carcinoma, papilloma, fibroadenoma, and invasive ductal carcinoma that have a papillary component. We present cytomorphological features of nipple discharge and FNA of breast lump in a 32-year female.

  4. Two-miRNA classifiers differentiate mutation-negative follicular thyroid carcinomas and follicular thyroid adenomas in fine needle aspirations with high specificity

    DEFF Research Database (Denmark)

    Stokowy, Tomasz; Wojtas, Bartosz; Jarzab, Barbara

    2016-01-01

    Diagnosis of thyroid by fine needle aspiration is challenging for the "indeterminate" category and can be supported by molecular testing. We set out to identify miRNA markers that could be used in a diagnostic setting to improve the discrimination of mutation-negative indeterminate fine needle...... aspirations. miRNA high-throughput sequencing was performed for freshly frozen tissue samples of 19 RAS and PAX8/PPARG mutation-negative follicular thyroid carcinomas, and 23 RAS and PAX8/PPARG mutation-negative follicular adenomas. Differentially expressed miRNAs were validated by quantitative polymerase...... chain reaction in a set of 44 fine needle aspiration samples representing 24 follicular thyroid carcinomas and 20 follicular adenomas. Twenty-six miRNAs characterized by a significant differential expression between follicular thyroid carcinomas and follicular adenomas were identified. Nevertheless...

  5. Fibroadenoma: can fine needle aspiration biopsy avoid short term follow-up?

    Science.gov (United States)

    Leconte, I; Abraham, C; Galant, C; Sy, M; Berlière, M; Fellah, L

    2012-10-01

    To confirm whether fine needle aspiration biopsy (FNAB) can avoid close monitoring, a source of worry for women patients with a suspected fibroadenoma found by ultrasound, and requiring their compliance. Over 39months, 427 nodules with a diagnosis of fibroadenoma were sampled in 372 patients using ultrasound-guided FNAB. The sonographic appearance of all the nodules suggested BI-RADS category 3 fibroadenomas. The mean size of the fibroadenomas was 9mm. The mean duration of follow-up was 29.7months. Seven nodules had atypical cytology: a microbiopsy and/or excision found a simple fibroadenoma (n=3), mastitis (n=1), a fibroadenoma associated with a papilloma (n=1), fibrosis (n=1) and normal tissue (n=1). Seven other nodules were resected during treatment for synchronous cancer, and were diagnosed as fibroadenomas. Two hundred and seventy-six nodules were followed-up (121 patients were lost to follow-up [n=132]) and the appearance of 263 nodules (95.29%) was stable. Seven nodules, which had increased in size, underwent another FNAB or microbiopsy or surgery. Five nodules were not found again. The borders of one nodule showed modifications. The use of fine needle aspiration biopsy, interpreted by an experienced cytologist, means that short term follow-up of fibroadenomas can be avoided. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  6. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  7. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  8. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  9. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    OpenAIRE

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial...

  10. Value of fine-needle aspiration biopsy of salivary gland lesions

    DEFF Research Database (Denmark)

    Christensen, Rikke Kølby; Bjørndal, Kristine; Godballe, Christian

    2010-01-01

    BACKGROUND: The aim of this study was to assess the utility of fine-needle aspiration biopsy (FNAB) in the diagnosis and treatment planning of the lesions of the salivary gland. METHODS: Eight hundred seventy-nine aspiration biopsies of the lesion of the salivary gland over a 10-year period, from...... was 98%, and the negative predictive value was 97%. The overall accuracy was 93%. The correct subtyping of the benign lesions was 97%, and the exact type-specific concordance of the malignant lesions was 71%. CONCLUSION: Considerable benefit to the patient may result from the cautious use of FNAB...

  11. Patterns of lymphadenopathy on fine needle aspiration cytology in eastern Nepal

    Directory of Open Access Journals (Sweden)

    N Mainali

    2015-09-01

    Full Text Available BACKGROUND: Lymphadenopathy is a commonly encountered clinical problem. Fine needle aspiration cytology offers the alternative of an immediate, preliminary, although not always specific diagnosis with little trauma and cost, thus providing ample information for further management and reduce the amount of open biopsy.MATERIAL AND METHODS:  FNAC was performed using 21 gauge needle attached with 10ml disposable needle. Slides were prepared, two were air dried and stained with field stain where as two were fixed in ethanol and was stained with PAP stain. One slide was stained with Ziehl-Neelson stain. Field and PAP stained slide were reviewed and diagnosed by Pathologist.RESULT: Out of the 225 patients, reactive lymphadenitis was the most common diagnosis (54.2%, followed by tubercular lymphadenitis (33.44%. Among the age group percentage of tubercular lymphadenitis was more in 210-30 years of age.  Majority of the metastatic carcinoma was in cervical region, comprising mainly squamous cell carcinoma.CONCLUSION: Reactive lymphadenitis was the most common cause of lymphadenopathy especially in case of children. In case of older population, definite pathology for lymph node enlargement was found in most of the cases. Hence FNAC is warranted in lymphadenopathy, as it is simple yet of great diagnostic value.

  12. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  13. Fine needle aspiration cytology of dermal cylindroma

    Directory of Open Access Journals (Sweden)

    Parikshaa Gupta

    2014-01-01

    Full Text Available In this paper, we have described fine needle aspiration cytology (FNAC of a rare case of dermal cylindroma. A 40-year-old female presented with a lateral mid-cervical swelling fixed to the skin. FNAC smears showed multiple clusters of small, round to oval cells with hyperchromatic nuclei, inconspicuous nucleoli and scant cytoplasm. In addition, the background showed deposits of basement membrane type material. This was dark magenta colored pinkish globular material. The globules were occasionally surrounded by the basal type of cells. Occasional cells with elongated nuclei were also noted. Cytological diagnosis of skin adnexal tumor possibly cylindroma was offered. Subsequent histopathology of the swelling showed sheets and clusters of cells in a jigsaw puzzle-like fashion. Deposition of abundant basement membrane-like material was noted in between the tumor cells. A diagnosis of cylindorma was offered. FNAC along with the subcutaneous location of the tumor and absence of primary salivary gland tumor may help to diagnose such rare case.

  14. Fine needle aspiration diagnosis of a spontaneously infarcted fibroadenoma mimicking carcinoma: a case report.

    Science.gov (United States)

    Arora, Rajan; Abou-Bakr, Amany; Al Taleb, Ahmed

    2013-02-01

    Spontaneous infarction of fibroadenoma is an extremely rare complication in a nonpregnant/nonlactating female undergoing first-time aspiration. It can be misdiagnosed as carcinoma in all aspects of triple approach used for evaluation of patients with breast lesions. A 37-year-old woman presented to the outpatient surgical clinic with a 6-month history of a breast lump that was slowly increasing in size and had become painful during the past month. There was no history of any trauma or fine needle aspiration, and she was not pregnant or lactating. Mammogram and ultrasound revealed a 2.9-cm heterogenous hypoechoic suspicious lesion. No lymph nodes were detected in the axilla. Fine needle aspiration cytology was performed, and a diagnosis of benign breast lesion with features of infarction was rendered on cytology. The lump was excised surgically, and a histological diagnosis of infarcted fibroadenoma was made. Careful and diligent search for preserved benign epithelial cells on smears is the key to recognize this entity and avoid serious therapeutic implications.

  15. CASE REPORT:Chondrosarcoma of Rib on Fine Needle Aspiration Cytology – A Rare Site

    Directory of Open Access Journals (Sweden)

    Prakash M Patil

    2012-07-01

    Full Text Available Background: Fine needle aspiration cytology (FNAC is effective in the diagnosis of bone tumors when combined with careful radiologic and clinical evaluation. Chondrosarcomas often arise in the pelvis or bones of the trunk, but primary chest wall (rib chondrosarcomas are relatively rare. Case Reports: This is a case of a patient with a chondrosarcoma arising in the left lower rib who underwent resection. The patient was a 30-year-old man with a 10x8x6cm tumor in the anterior chest wall of the left side lower rib. On Fine Needle Aspiration Cytology (FNAC of the mass on the anterior chest wall, a diagnosis of a low grade chondrosarcoma was made. This was confirmed histopathologically as a dedifferentiated chondrosarcoma. Macroscopically on excision of gray to pink lobulated mass with adjacent soft tissue and bone with foci of hemorrhage and necrosis the mass measured (M 10x 8x 6 cm. Incidence of chondrosarcoma peaks in the 5th to 6th decade and most commonly involves the femur, humerus, pelvis, and scapula. It rarely involves rib.

  16. Testicular fine-needle aspiration for the assessment of intratesticular hormone concentrations

    Directory of Open Access Journals (Sweden)

    Ada P Lee

    2016-01-01

    Full Text Available Measurement of intratesticular sex steroid concentrations in men informs both the development of male hormonal contraceptives and the understanding of male infertility. Given the challenges of using invasive techniques to measure testicular hormone physiology, our group has used a minimally-invasive fine-needle aspiration technique to measure intratesticular hormones in normal healthy men. Herein, we present a post-hoc analysis of the safety and efficacy of testicular fine-needle aspiration (FNA completed as part of six clinical trials. From 2001 through 2011, a total of 404 procedures were conducted among 163 research volunteers, 85.9% of which were successful in obtaining sufficient fluid for the measurement of intratesticular steroid concentrations. Pain was the most common side effect, with 36.8% of procedures associated with moderate procedural pain and 4.7% with severe procedural pain. Postprocedural pain was uncommon and abated within a few days. Mild local bruising occurred with 14.9% of procedures. Two serious adverse events (0.5% required surgical intervention. The risk of an adverse event was not associated with age, body mass index, testicular size, or the volume of fluid aspirated. Testicular FNA to obtain fluid for measurement of intratesticular steroid concentrations frequently causes mild to moderate procedural pain, but serious adverse events occur rarely. Testicular FNA has been instrumental for defining human intratesticular hormone physiology and is a minimally-invasive, safe, effective method for obtaining fluid for research on testicular physiology and pathology.

  17. Evolution of the mammary capillary network and carbonic anhydrase activity throughout lactation and during somatotropin treatment in goats

    DEFF Research Database (Denmark)

    Nielsen, Mette Benedicte Olaf; Cvek, Katarina; Dahlborn, Kristina

    2010-01-01

    involved in the coordination of mammary blood flow (MBF) and metabolic activity. Milk vein blood velocity was determined as a measure of MBF, and fine needle mammary biopsies were obtained at different time points during lactation and by the end of a 14-d bovine somatotropin (BST) treatment initiated 3...... almost tripled in size, whereas number of capillaries surrounding each alveolus decreased by 1/3, and CA activity more than halved. BST treatment did not affect capillary traits but increased number of alveoli in mammary sections, and BST thus appeared to be targeted mostly towards the mammary epithelial...

  18. Role of AgNORs in thyroid lesions on fine needle aspiration cytology smears

    Directory of Open Access Journals (Sweden)

    Asotra Sarita

    2008-01-01

    Full Text Available Background: Fine needle aspiration has an important role in diagnosis of thyroid neoplasm. However, it is difficult to differentiate between follicular adenoma and follicular carcinoma by cytology alone. Recently, silver staining has been performed for nucleolar organizer regions (AgNORs to differentiate various tumors. Aims: The present study was undertaken to see if the AgNOR technique could distinguish between benign and malignant lesions, particularly, follicular neoplasm. Materials and Methods: One hundred forty cases of thyroid lesions were examined, which included colloid goiter (n = 36, multinodular goiter (n = 38, subacute thyroiditis (n = 6, Hashimoto′s thyroiditis (n = 17, lymphocytic thyroiditis (n = 3, follicular neoplasm (n = 18, Hurthle cell neoplasm (n = 3, papillary carcinoma (n = 16, and medullary carcinoma (n = 3. Diagnosis was confirmed by histopathology in 80 cases. The usual one-step silver colloidal reaction was performed at room temperature for 35 minutes and intranuclear dots of silver deposits were counted in 100 cells. Results: AgNOR counts of benign and malignant lesions were compared and were found to be statistically significant (P < 0.001. The mean AgNOR counts were higher in neoplastic lesions. Conclusions: AgNOR counting in fine needle aspiration smears is a simple, sensitive, and cost-effective method for differentiating benign from malignant thyroid follicular neoplasms.

  19. Influence of the capillary on the ignition of the transient spark discharge

    International Nuclear Information System (INIS)

    Gerling, T; Hoder, T; Brandenburg, R; Bussiahn, R; Weltmann, K-D

    2013-01-01

    A self-pulsing negative dc discharge in argon generated in a needle-to-plane geometry at open atmosphere is investigated. Additionally, the needle electrode can be surrounded by a quartz capillary. It is shown that the relative position of the capillary end to the needle tip strongly influences the discharge inception and its spatio-temporal dynamics. Without the capillary for the selected working parameters a streamer corona is ignited, but when the capillary surrounds the needle, the transient spark (TS) discharge is ignited after a pre-streamer (PS) occurs. The time between PS and TS discharge depends on the relative capillary end position. The existence of the PS is confirmed by electro-optical characterization. Furthermore, spectrally and spatio-temporally resolved cross-correlation spectroscopy is applied to show the most active region of pre-phase emission activity as indicators for high local electric field strength. The results indicate that with a capillary in place, the necessary energy input of the pre-phase into the system is mainly reduced by additional electrical fields at the capillary edge. Even such a small change as a shift of dielectric surface close to the plasma largely changes the energy balance in the system. (paper)

  20. Fine needle aspiration biopsy diagnosis of metastatic neoplasms of the breast. A three-case report

    Directory of Open Access Journals (Sweden)

    Raquel Garza-Guajardo

    2005-09-01

    Full Text Available Abstract Metastases to the breast are unusual lesions that make up approximately 2% of all malignant mammary neoplasms and may mimic both benign and malignant primary neoplasms from a clinical point of view, as well as in imaging studies. Arriving at a correct diagnosis is therefore essential in order to establish appropriate management. We present three cases of metastatic neoplasms diagnosed through fine needle aspiration biopsy and immunocytochemistry. The cytological diagnoses were: medulloblastoma in an 18-year-old woman, melanoma in a 26-year-old man, and an exceptional case of ovarian sarcoma originating from a granulosa cell tumor with metastases to both breasts. A metastatic disease should be considered in the differential diagnosis of a palpable mass in the breast, especially if there is a history of an extramammary malignant neoplasm. Fine needle aspiration biopsy is the method of choice for the management of these cases. Whenever possible the exam of the material obtained should be compared to the previous biopsy, which is usually enough to arrive at a correct diagnosis, thus preventing unnecessary surgical procedures.

  1. Needle stick injuries during fine needle aspiration procedure: Frequency, causes and knowledge, attitude and practices of cytopathologists

    Directory of Open Access Journals (Sweden)

    Neeta Kumar

    2011-01-01

    Full Text Available Background: There is no study available on the frequency, predisposing factors and outcome of needle stick injury (NSI in cytopathologists who perform fine needle aspiration (FNA. Aim: To know the frequency, circumstances and sequlae of NSI sustained by cytopathologists, assess their knowledge about risks of NSI and attitudes and practices towards use of standard precautions and post-injury wound care. Materials and Methods: Study design: cross sectional. Setting: Tertiary care teaching and non-teaching hospitals and private laboratories. Data collection method: Knowledge, attitude and practices survey using a questionnaire. Results: Majority (90.5% of the respondents have had NSI in their total career. In the previous year, more than half (71.4% had at least one NSI (mean 3.2. NSI was the most common in index finger of non-dominant hand (59.6% and occurred during step two of FNA procedure when the needle was being manipulated within the lump. The major predisposing factors were uncooperative patients (88.9%, small children (54%, deep masses (36.5%, hot humid climate (88.9%, heavy workload (76.2% and poor administrative arrangement (54%. The adherence to standard precautions was not optimal (74.6%. None of them reported NSI to the authorities, nor investigated source patient or themselves. 82.5% of the respondents were not aware of any formal exposure reporting system in their hospital. Conclusion: Cytopathologists frequently experience NSI while performing FNA. Frequency of injury is also related to patient characteristics and work site factors. Education and motivation for adhering to standard precautions and post-exposure prophylaxis are often lacking.

  2. Incisional endometriosis: diagnosed by fine needle aspiration cytology.

    Science.gov (United States)

    Veda, P; Srinivasaiah, M

    2010-07-01

    Incisional endometriosis (IE) is a rare entity reported in 0.03-1.08% of women following obstetric or gynecologic surgeries. Most cases reported in literature have appeared after cesarean sections and were often clinically mistaken for hernia, abscess, suture granuloma or lipoma. We hereby report a case of IE following a second trimester hysterotomy, which was diagnosed by fine needle aspiration cytology (FNAC). Our patient was 26 years old, presenting with a mass over anterior abdominal wall, associated with incapacitating pain during each menstrual cycle. FNAC showed epithelial cells, stromal cells and hemosiderin laden macrophages. Based on the typical history, clinical and cytological features, the diagnosis of IE was established. Wide surgical excision was done and the resulting rectus sheath defect was repaired. Patient was followed for 6 months during which time she was symptom free. This article also reviews the spectrum of cytological features and the rare possibility of malignant transformation that can occur in IE.

  3. Fine-needle aspiration cytology as a diagnostic modality for cysticercosis: A clinicocytological study of 137 cases

    Directory of Open Access Journals (Sweden)

    Pooja Kala

    2014-01-01

    Conclusion: Fine-needle aspiration cytology in cysticercosis is a low-cost outpatient procedure. The cytological diagnosis is quite straightforward in cases where the actual parasite structures are identified in the smears. In other cases, a cytological diagnosis of suspicious of cysticercosis can be given if the cytological findings suggest the same.

  4. Endoscopic Ultrasound Fine-Needle Aspiration Characteristics of Primary Adenocarcinoma versus Other Malignant Neoplasms of The Pancreas

    Directory of Open Access Journals (Sweden)

    Veronika Gagovic

    2012-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA is often used to assist in the evaluation of pancreatic lesions and may help to diagnose benign versus malignant neoplasms. However, there is a paucity of literature regarding comparative EUS characteristics of various malignant pancreatic neoplasms (primary and metastatic.

  5. Guided fine needle aspiration cytology of retroperitoneal masses - Our experience

    Directory of Open Access Journals (Sweden)

    Mimi Gangopadhyay

    2011-01-01

    Full Text Available Background : Early pathological classification of retroperitoneal masses is important for pin-point diagnosis and timely management. Aims : This study was done to evaluate the usefulness and drawbacks of guided fine needle aspiration cytology (FNAC of retroperitoneal masses covering a period of two years with an intention to distinguish between neoplastic and non-neoplastic lesions and to correlate with histologic findings. Materials and Methods : FNAC was done under radiological guidance in all cases using long needle fitted with disposable syringe. Appropriate staining was done and cytology was correlated with histology which was taken as the gold standard for comparison. Results : Fifty-one patients who presented with retroperitoneal masses were studied. Forty-four lesions were malignant cytologically and 7 were inflammatory (tuberculous. According to radiological and cytologic findings, we classified our cases into four groups: renal tumors, retroperitoneal lymphadenopathy, germ cell tumors, soft tissue tumors. Except for cases of non-Hodgkin lymphoma (NHL and metastatic lesions, we had sensitivity and specificity of 100%. In NHL the sensitivity and specificity were both 50%. In cases of metastatic adenocarcinoma, the sensitivity and specificity were 84.6% and 81.8%, respectively. Conclusions : Ignoring the pitfalls, guided FNAC is still an inexpensive and reliable method of early diagnosis of retroperitoneal lesions.

  6. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  7. Fine needle biopsy of thyroid nodules: correlations between cytology and gistology, technical aspects

    Directory of Open Access Journals (Sweden)

    Yu Fedotov

    2009-12-01

    Full Text Available The results of comparative preoperative cytological and postoperative histological investigation of 3714 patients with thyroid nodules are presented. The causes of discrepancies are discussed and measures of their diminution are proposed. Great value of fine needle biopsy to differ thyroid nodules but follicular neoplasia into benign and malignant are determined. Its sensitivity in our clinics is 98.7% and specificity – 100%. Necessity of the of the second FNA if the first one is non informative is established.

  8. The diagnostic value of thyroglobulin concentration in fine-needle aspiration of the cervical lymph nodes in patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Mikosinski, S.; Oszukowska, L.; Makarewicz, J.; Adamczewski, Z.; Lewinski, A.; Pomorski, L.; Sporny, S.

    2006-01-01

    Introduction: Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. Material and methods: The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and 131I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15 - 711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94 - 100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Results: Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. Conclusions: 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes

  9. Mixed germ cell tumor of mediastinum/lung masquerading as hemangioma in fine needle biopsy

    Directory of Open Access Journals (Sweden)

    Rathna Nuti

    2013-01-01

    Full Text Available The histological predominance of one component in a germ cell tumor can lead to a mistaken diagnosis. Here, we describe a mediastinal teratoma with predominant vascular proliferation (>90% which on fine needle biopsy was diagnosed as a pulmonary hemangioma. Later, resection specimen revealed other components constituting ~4%, changing the diagnosis while illustrating theimportance of careful evaluation. A 37-year-old Caucasian male with shortness of breath, weight loss, and history of recently resolved pneumonia was diagnosed with hemangioma, after a computed tomography guided fine needle biopsy of a -16.3-cm mediastinal pulmonary mass revealed abundant benign vascular elements. Following tumor excision, ~94% of the sample exhibited predominant vascular elementsThe mass also exhibited rare focal areas of malignant epithelium in a reticular arrangement and undifferentiated pleomorphic cells associated with vascular invasion. These atypical epithelial cells were positive for CD30, pan CK, AFP, β-HCG and CD 117, thusprocuring a diagnosis of mediastinal mixed germ cell tumor. Although mixed germ cell tumors consist of various tissue types, diagnosis can be easily overlooked if one component dominates. Therefore, obtaining adequate representative neoplasm samples, and sectioning the samples thoroughly, searching for coexisting tissue types is critical for accurate diagnosis.

  10. Diagnosis of verminous pneumonia via sonography-guided fine-needle pulmonary parenchymal aspiration in a cat

    Directory of Open Access Journals (Sweden)

    Jennifer Gambino

    2016-04-01

    Full Text Available Case summary A 9-year-old, male neutered, indoor–outdoor domestic shorthair cat from the northern Alabama countryside presented for a 3 week history of coughing, lethargy and an episode of self-resolving dyspnea that occurred 1 week prior to presentation. Three-view thoracic radiographs revealed a moderate-to-severe, diffuse, mixed bronchial to structured interstitial (miliary-to-nodular pulmonary pattern in all lung lobes with peribronchial cuffing and multifocal areas of mild patchy alveolar opacity. Ultrasound-guided evaluation and fine-needle aspiration of the caudodorsal lung parenchyma was performed with sedation. Cytology revealed many widely scattered Aelurostrongylus abstrusus larvae and ova. Upon the confirmed diagnosis of A abstrusus verminous pneumonia, treatment with fenbendazole and selamectin resulted in complete resolution of clinical signs within 6 weeks of the initial diagnosis. Relevance and novel information We report herein the first documented case in the Americas of A abstrusus verminous pneumonia diagnosed via cytologic evaluation of an in vivo, percutaneous ultrasound-guided fine-needle aspirate of affected lung. Additionally, to our knowledge, we offer the first account of the sonographic (pulmonary features of the disease.

  11. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  12. Risk factors of pneumothorax in percutaneous fine needle aspiration biopsy of the lung

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Park, Kwang Joo; Shin, Hyung Cheol; Kwon, Ryang; Jo, Byung June; Oh, Sei Jung; Ahn, Chang Su; Kim, Hyung Jung

    1997-01-01

    Percutaneous fine needle aspiration biopsy is known to be a useful diagnostic method for the diagnosis of various pulmonary diseases. Its diagnostic yield is high, and it is safe, but complications such as pneumothorax can occasionally occur. We reviewed the complications arising after needle aspiration biopsy and analyzed the risk factors of pneumothorax. The medical records and radiographic studies of 157 patients with various pulmonary diseases who underwent needle aspiration biopsy of the lung between 1990 and 1996 were retrospectively reviewed. The clinical features, treatment, and courses of complications were reviewed, and risk factors of pneumothorax such as depth and size of lesion, diameter of needle, number of punctures, and obstructive pulmonary abnormalities were analyzed. Complications occurred in 40 of 157cases(25.5%), namely pneumothorax in 26(16.6%), hemoptysis in 11(7%), hemothorax in two(1.3%), and recurrence of malignancy at the site of aspiration in one(0.6%). When the patients were divided into three groups according to depth of lesion, there were significant difference in the incidence of pneumothorax;the results were as follows:less than 2cm, 12.9%;between 2 and 4cm, 24.1%;and larger than 4cm, 57.1%(p<0.05). In pulmonary function testing, FVC(Forced Vital Capacity) of patients with pneumothorax was less than that of patients without(2.6±0.9L vs 3.1±0.8L, p<0.05), but FEV1(Forced Expiratory Volume in 1 second), FEV1%(percentage of predicted FEV1), FEV1/FVC, and FVC% (percentage of predicted FVC) were not different between the two groups. The incidence of pneumothorax in patients with pleura-at-tached lesion (9%) was lower than that of those with non-attached lesion(26%, p=3D0.01). The age of patients, size of lesion, diameter of the needle, guidance methods and number of aspirations showed no significant relationship with pneumothorax. In needle aspiration biopsy of the lung, depth of lesion and passage of a needle through aerated lung are

  13. Fine needle aspiration cytology and cell block in the diagnosis of seminoma testis

    Directory of Open Access Journals (Sweden)

    Abhishant Pandey

    2011-01-01

    Full Text Available Testicular neoplasms which show a wide variety of morphologic types, comprise a small proportion of malignancies. Early identification and treatment is essential for achieving long term survival. The cytologic findings in fine needle aspiration smears from left testicular swelling of a 49 year old male suggestive of a germ cell tumor was complimented by cell block preparation as seminoma. This was confirmed by histopathologic studies. We are presenting this case to emphasize that cell block can be used for diagnosis of testicular tumors.

  14. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  15. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...

  16. The penetration of aerosols through fine capillaries

    International Nuclear Information System (INIS)

    Mitchell, J.P.; Edwards, R.T.; Ball, M.H.E.

    1989-10-01

    A novel experimental technique has been developed to study the penetration of aerosol particles ranging from about 1 to 15 μm aerodynamic diameter through capillaries varying from 20 to 80 μm bore and from 10 to 50 mm in length. When the driving pressure was 100 kPa, the penetration of the airborne particles was considerably smaller than expected from a simple comparison of particle diameter with the bore of the capillary. Particle size distributions determined after penetration through the capillaries were in almost all cases similar to the particle size distribution of the aerosol at the capillary entrance. This lack of size-selectivity can be explained in terms of the capillary behaving as a conventional suction-based sampler from a near still (calm) air environment. The resulting particle penetration data are important in assessing the potential for the leakage of aerosols through seals in containers used to transport radioactive materials. (author)

  17. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  18. Scalp Melanoma Diagnosed by Fine Needle Aspiration Cytology in a Tertiary Health Center

    Directory of Open Access Journals (Sweden)

    A. B. Zarami

    2015-01-01

    Full Text Available Melanoma is one of the most aggressive malignant skin neoplasms worldwide with more than 20% of world melanoma seen in black Africa and Asia. Late presentation due to ignorance, poverty, and lack of adequate health facility in Nigeria is always the norms. We present this case report because of precision in diagnosis, using fine needle aspiration cytology (FNAC to reemphasize that the technique is cheap, cost effective, and quick that can reduce the burden of incisional biopsy before definitive surgery and improve early detection of the disease especially in developing countries.

  19. Added value of thyroglobulin measurement in the fine-needle aspiration washout to diagnose cervical metastatic lymphadenopathy from papillary thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Lan; Lee, Tae Hyun; Park, Dong Hee [Dept. of Diagnostic Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-11-15

    The aim of this study was to evaluate added value and diagnostic threshold value of thyroglobulin measurement in the fine-needle aspiration washout for detecting cervical lymph node metastasis from papillary thyroid cancer on pre and postoperative patients. Total 219 cervical lymph nodes from 180 patients with papillary thyroid cancer were evaluated for fine needle aspiration cytology and thyroglobulin in fine needle aspiration (FNA-Tg), using immunometric chemiluminescent assay. Eighty-six patients were preoperative and remaining 94 patients were on follow up after total thyroidectomy. Final diagnoses were made on pathology of dissected lymph nodes or follow-up examination for at least 12 months. One hundred and twelve metastatic lymph nodes were finally confirmed in 94 patients out of total 180 patients. Sensitivity of FNA-Tg was 99.1, 98.21, 97.20%, respectively with threshold level at 1, 10, serum Tgng/mL, which were higher sensitivity of fine needle aspiration. Combined FNA and FNA-Tg with threshold at 1, 10, 100 ng/mL raised sensitivity and specificity to 100%, respectively. All 6 lymph nodes that were false negative on FNA were correctly diagnosed as metastasis on FNA-Tg with threshold of 1, 10, 100, and serum thyroglobulin. FNA-Tg with threshold level at 100 ng/mL combined FNA showed highest sensitivity (100%) and specificity (97.56%) on preoperative patient groups among the 1, 10, 100, serum Tg threshold value. But, FNA only showed adequately high sensitivity (100%) and specificity (96.96%) on postoperative patient groups. Using receiver operating characteristic curve (ROC) curve analysis, cut off value was 57.69 in total patient, 78.66 in preoperative patient, and 32.81 in postoperative patient. FNA-Tg combined with FNA showed excellent sensitivity and specificity. FNA-Tg showed very high sensitivity and specificity at threshold level 78.66 ng/mL in preoperative patients, but FNA-Tg had less benefit on the postoperative patient group, having high

  20. Fine needle aspiration cytology in leprosy

    Directory of Open Access Journals (Sweden)

    Prasad PVS

    2008-01-01

    Full Text Available Background: Laboratory diagnosis of leprosy by slit skin smear and skin biopsy is simple but both techniques have their own limitations. Slit skin smear is negative in paucibacillary cases whereas skin biopsy is an invasive technique. Fine needle aspiration cytology (FNAC from skin lesions in leprosy with subsequent staining with May-Grunwald-Giemsa (MGG stain has been found useful. Aim: To evaluate the possible role of cytology in classifying leprosy patients. Methods: Seventy-five untreated cases of leprosy attending the outpatient department were evaluated. Smears were taken from their skin lesions and stained using the MGG technique. Skin biopsy was also done from the lesions, which was compared with cytology smears. Results: A correlation of clinical features with FNAC was noticed in 87.5% of TT, 92.1% of BT, 81% of BL, and 66% of LL cases. Correlation of clinical with histopathological diagnoses revealed 12.5% specificity in TT leprosy, 55.3% in BT, 52.4% in BL and 50% in LL, and 100% in neuritic and histoid leprosy cases. Both correlations were found to be statistically significant by paired t test analysis. Thus, it was possible to distinguish the tuberculoid types by the presence of epithelioid cells and the lepromatous types by the presence of lymphocytes and foamy macrophages. Conclusion: FNAC may be used to categorize the patients into paucibacillary and multibacillary types, but is not a very sensitive tool to classify the patients across the Ridley-Jopling spectrum.

  1. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  2. A correlation study of diagnostic fine-needle aspiration with histologic diagnosis in cystic neck lesions.

    Science.gov (United States)

    Moatamed, Neda A; Naini, Bita V; Fathizadeh, Payman; Estrella, Julie; Apple, Sophia K

    2009-10-01

    The clinical diagnosis of a mass in the neck region encompasses a wide spectrum of differential diagnosis. Fine-needle aspiration is a quick and safe technique, which can provide useful information for initial assessment and further therapeutic measures. The aim of this retrospective study was to evaluate the performance characteristics of the fine-needle aspiration (FNA) in cystic neck lesions. Of 142 patients with FNA for cystic neck masses during 2002-2007, 92 cases were selected with a follow-up histologic diagnosis, excluding the cystic colloid nodule of the thyroid. The cases were divided into salivary gland cystic neck (37 patients) and non-salivary cystic neck (55 patients) mass groups. False-positive and false-negative diagnoses were applied only to the malignant lesions after confirmation by histopathology. In the first group, nine malignant and 28 benign diagnoses were made by FNA; of which three were false-negative. In the second group, there were nine malignant and 46 benign diagnoses with three false negatives. The overall performance of the FNA showed 76% sensitivity and 100% specificity. In conclusion, FNA of the cystic neck lesions offers an invaluable and highly specific initial diagnostic approach for the management of the patients. (c) 2009 Wiley-Liss, Inc.

  3. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  4. Bayesian network modelling on data from fine needle aspiration cytology examination for breast cancer diagnosis

    OpenAIRE

    Ding, Xuemei; Cao, Yi; Zhai, Jia; Maguire, Liam; Li, Yuhua; Yang, Hongqin; Wang, Yuhua; Zeng, Jinshu; Liu, Shuo

    2017-01-01

    The paper employed Bayesian network (BN) modelling approach to discover causal dependencies among different data features of Breast Cancer Wisconsin Dataset (BCWD) derived from openly sourced UCI repository. K2 learning algorithm and k-fold cross validation were used to construct and optimize BN structure. Compared to Na‹ve Bayes (NB), the obtained BN presented better performance for breast cancer diagnosis based on fine needle aspiration cytology (FNAC) examination. It also showed that, amon...

  5. Fine needle aspiration cytology of unilesional mycosis fungoides d′emblee

    Directory of Open Access Journals (Sweden)

    K Amita

    2012-01-01

    Full Text Available Primary cutaneous T-cell lymphoma is a rare lymphoproliferative disorder accounting for 2% of all lymphomas. Mycosis fungoides (MF is a rare, albeit commonest form of primary cutaneous T cell lymphoma. MF d′emblee is an uncommon variant which is easily mistaken clinically for epithelial malignancy. Diagnosis at cytology is challenging due to low degree of suspicion, rare occurrence and diverse morphology. We report a case of 51-year-old male presenting with a solitary nodulo-ulcerative lesion over right thigh. Smear showed atypical lymphocytes with hyper-convoluted cerebriform nuclei along with few mature lymphocytes consistent with MF. To our knowledge, this is the first report of unilesional MF d′emblee diagnosed at fine needle aspiration cytology (FNAC. Our case emphasizes that FNAC is an accurate method for early diagnosis and clinical staging of patients with MF.

  6. Umbilical metastasis (Sister Mary Joseph's nodule diagnosed by fine-needle aspiration

    Directory of Open Access Journals (Sweden)

    Tatomirović Željka

    2004-01-01

    Full Text Available Sister Mary Joseph’s nodule is the eponym for metastatic involvement of the umbilicus. This less common entity is the sign of disseminated malignant disease, mainly of digestive and gynecologic origin, and is associated with a poor prognosis. A case of Sister Mary Joseph’s nodule in a 76-year-old woman in whom the umbilical metastasis was the first sign of malignant disease in presented. The diagnosis of metastatic adenocarcinoma was established by fine needle aspiration cytology of the umbilical nodule. Radiological and ultrasonographic investigation disclosed carcinoma of the gallbladder with pancreas, stomach, and colon invasion as well as peritoneal dissemination. The diagnosis was confirmed by exploratory laparatomy and histological examination of the excised umbilical nodule.

  7. Comparative study of aspiration and non-aspiration cytology of palpable breast lumps and correlation with histopathology

    Directory of Open Access Journals (Sweden)

    S Koirala

    2014-09-01

    Full Text Available Background: Breast lump is one of the most common presentations in surgical outpatient departments with anxiety regarding a possible malignancy. Hence a quick diagnosis of a lump in the breast is essential. Fine needle aspiration cytology is an ideal initial diagnostic modality in breast lumps. There is an alternative method of performing needle aspiration, known as fine needle capillary cytology where the specimen is obtained using just a needle without aspiration.Materials and Methods: This hospital-based cross sectional analytical study was carried out in Department of Pathology in National Academy of Medical Sciences, Bir Hospital for one year. The objective of this study was to compare aspiration and non-aspiration cytology of palpable breast lumps and correlation with histopathology.Results: The five criteria scored for each technique were background blood, amount of cellular material, cellular degeneration, cellular trauma and architectural preservation. Compared to fine needle aspiration cytology, fine needle capillary cytology yields less bloody smears with minimal degenerative changes and offers more diagnostically superior specimens. Fine needle aspiration cytology, on the other hand, gives a good yield of diagnostic material.Conclusion: Fine needle aspiration cytology and fine needle capillary cytology are quick, easy, safe and cost-effective techniques. . A high sensitivity and specificity of cytological diagnosis in this study proves that it is comparable to final histology report in its diagnostic efficiency. Thus, fine needle aspiration cytology is a very important preliminary diagnostic test in palpable breast lumps and the results show a high degree of correlation with the final histopathology report.DOI: http://dx.doi.org/10.3126/jpn.v4i8.11501 Journal of Pathology of Nepal; Vol.4,No. 8 (2014 639-643

  8. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  9. Huge pelvic parachordoma: fine needle aspiration cytology and histological differential diagnosis

    Directory of Open Access Journals (Sweden)

    Mona A. Kandil

    2012-10-01

    Full Text Available Parachordoma is an extremely rare soft tissue tumor of unknown lineage. Parachordoma develops most often on the extremities. Only 2 cases have been reported as pelvic parachordoma. A 46-year old Egyptian woman with a huge painful pelvic mass was found to have a parachordoma with ectopic pelvic right kidney. There is only one report in the literature of fine needle aspiration cytology in this setting. The microscopic picture of parachordoma is not new to pathologists but the gross picture of this rare tumor has not previously been published; not even in the World Health Organization classification of soft tissues tumors. Diagnosis was confirmed by immuno-histochemistry. The patient is in good clinical condition without any evidence of recurrence or metastasis after 84 months of follow up.

  10. Impact of Molecular Screening for Point Mutations and Rearrangements in Routine Air-Dried Fine-Needle Aspiration Samples of Thyroid Nodules

    DEFF Research Database (Denmark)

    Eszlinger, Markus; Krogdahl, Annelise; Münz, Sina

    2014-01-01

    Background: The diagnostic limitations of thyroid fine-needle aspiration (FNA), such as the indeterminate category, can be partially overcome by molecular analyses. However, until now, rearrangements have only been detected in fresh FNA material and the number of follicular thyroid carcinomas (FT...

  11. Thyroid Fine-Needle Aspiration under Ultrasound Guidance: Experience from an Academic Tertiary Care Center in Lebanon

    Directory of Open Access Journals (Sweden)

    Rita Hajj Boutros

    2017-07-01

    Full Text Available Thyroid nodules are common. Malignancy was reported in only 5-15% of cases. Fine needle aspiration under US guidance (USG-FNA proved to be accurate for the detection of thyroid cancer. This is a retrospective review of 400 radiology and cytology USG-FNA reports, randomly selected among those done at the Radiology Department at a tertiary care center in Beirut during the last five years. The specimen was inadequate in 60 (12% of cases but FNA was repeated in 10 cases only. The final diagnosis was benign in 76.7% of cases, mostly in women. 35% of the malignant and 19% of the benign nodules were hypoechoic, p=0.03. No significant correlation was observed between malignancy and other ultrasonic characteristics. Hypoechogenecity was also more common in nodules with inadequate specimen (40% versus 21.4%, p=0.01. Age, gender, location and size of the nodule did not differ between groups of adequate and inadequate specimen. In conclusion, 3 out of 4 thyroid nodules referred for USG-FNA are benign, mostly in women. Inadequate specimen was observed in 12% of cases. Hypoechogenecity but not other ultrasonic characteristics was associated with malignancy and with test failure.   Key words: Thyroid nodule, fine needle aspirate, ultrasound guidance, thyroid cancer, inadequate.

  12. Pancreatic metastases from ocular malignant melanoma: the use of endoscopic ultrasound-guided fine-needle aspiration to establish a definitive cytologic diagnosis: a case report

    Directory of Open Access Journals (Sweden)

    Diogo Turiani Hourneaux De Moura

    2016-12-01

    Full Text Available Abstract Background When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. Case presentation A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL. Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm, localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. Conclusions To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has

  13. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  14. Fine-needle aspiration findings of a rare hematopoietic neoplasm presenting as obstructive jaundice.

    Science.gov (United States)

    Tracht, Jessica; Ahmed, Ali M; Rosenblum Donath, Frida

    2017-12-01

    A 51-year-old female who presented with obstructive jaundice was found to have masses in the pancreatic head and tail as well as suspicious liver and periaortic masses on imaging. Aspiration cytology of the pancreatic tail mass showed abundant large single cells with vacuolated eosinophilic cytoplasm, marked nuclear pleomorphism, large bizarre irregular nuclei, binucleation, and prominent nucleoli. Numerous cells also showed intracytoplasmic black to brown pigmentation. A cell block was obtained and extensive immunohistochemical staining was performed. S-100, HMB-45, Sox10, pancytokeratin, CK7, RCC antigen, synaptophysin, HepPar 1, inhibin, CD45, CD21, and CD123 were negative, making melanoma, epithelial malignancies, lymphoma, follicular dendritic and plasmacytoid dendritic cell neoplasms less likely. CD4 and CD56 showed partial positivity, and CD68, CD163, and CD14 were positive, supporting the diagnosis of histiocytic sarcoma. Surgical specimens and immunohistochemistry confirmed the cytologic findings. Histiocytic sarcoma is a rare aggressive malignancy of histiocytic origin with most cases presenting in adults in extranodal sites, most commonly the intestinal tract. Few cases are reported in the literature, presenting diagnostic challenges for cytopathologists when seen on fine-needle aspiration. We present the first reported case of histiocytic sarcoma presenting as a pancreatic mass, diagnosed by endoscopic ultrasound guided fine-needle aspiration (EUS-FNA). This entity is rarely described on cytology and arose in a location in which EUS-FNA is the diagnostic modality of choice. This case study highlights that cytopathologists should be aware of histiocytic sarcoma occurring in extranodal locations accessible by EUS-FNA and be familiar with the cytomorphologic appearance. © 2017 Wiley Periodicals, Inc.

  15. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kümmerlin, I.P.E.D.; Ten Kate, F.J.; Algaba, F.; Trias, I.; Wijkstra, H.; Rosette, de la J.J.M.C.H.; Laguna, M.P.

    2013-01-01

    Purpose Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by

  16. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kummerlin, I. P.; ten Kate, F. J.; Algaba, F.; Trias, I.; Wijkstra, H.; de la Rosette, J. J.; Laguna, P.

    2013-01-01

    Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by five

  17. [Quality assurance of fine-needle aspiration cytology of the organized mammography screening].

    Science.gov (United States)

    Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós

    2010-08-08

    The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (pauditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.

  18. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin [Dept. of Radiology, Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of); Ryoo, Jae Wook [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jung, So Lyung [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-07-15

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules.

  19. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin; Ryoo, Jae Wook; Jung, So Lyung

    2016-01-01

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules

  20. Paraganglioma with unusual presentation in parotid gland: A diagnostic dilemma in fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Anagh A Vora

    2012-01-01

    Full Text Available Paragangliomas (PGLs are uncommon tumors. Although PGLs are known to occur in the head and neck region, especially the carotid body, middle ear, and larynx, involvement of the parotid glands has not been reported. In this article, we report the fine needle aspiration features of tumor in an unusual location, presenting as a parotid gland mass, submitted to pathology for initial diagnosis. The clinical presentation, cytomorphology, and the immunohistochemical features for the diagnosis are described. To our knowledge, this is the first case of paraganglioma of the parotid gland reported in the literature.

  1. Lymphography with percutaneous fine needle cytology for the detection of malignant lymph node involvement

    International Nuclear Information System (INIS)

    Fencl, P.; Mylbachr, L.; Neradov, M.; Starek, J.; Doleckova, M.

    1988-01-01

    The authors present their experience of lymphograpy and percutaneous fine needle cytological biopsy of 60 patients with malignancies. Cytological specimens were taken from 98 lymph nodes in patients with cervical cancer (36), vulvar cancer (2), uterine sarcoma (2), vesical cancer (2), prostate gland cancer (3), Hodgkin's lymphoma (4), non Hodgkin's lymphoma (6), seminoma (4), lung cancer (1). Malignant cells were found in 31 persons in 41 nodes. Half of the dubious lymphography nodes had malignant cells in the biopsy material. Curiously enough, the contrast medium causes granulomatous inflammation of time-dependent intensity. 3 refs.; 2 figs.; 2 tabs

  2. Application of B-ultrasonic guided fine needle aspiration cytology in diagnosis of tuberculous lymphadenitis

    International Nuclear Information System (INIS)

    Yu Qi; Yang Jianghui; Li Ning

    2011-01-01

    To explore the value of B-ultrasonic guided fine needle aspiration cytology(FNAC) in the diagnosis of tuberculous lymphadenitis (TB). The patients were carried out FNAC under B-ultrasonic guidance to distinguish the tuberculosis lymphadenitis. With the FNAC diagnosis of lymphoglandulae and reactive hyperplasia lesions of 80 cases, 41 cases were confirmed by histopathology. With FNAC diagnosed tuberculosis 36 cases, granulomatous lymphadenitis 2 cases and reactive hyperplasia 3 cases. FANC is one of efficient method to diagnosis the tuberculous lymphadenitis. This method has some limitations, but it could be overcome by biopsy or polymerase chain reaction. (authors)

  3. Introduction of a New Diagnostic Method for Breast Cancer Based on Fine Needle Aspiration (FNA) Test Data and Combining Intelligent Systems

    Science.gov (United States)

    Fiuzy, Mohammad; Haddadnia, Javad; Mollania, Nasrin; Hashemian, Maryam; Hassanpour, Kazem

    2012-01-01

    Background Accurate Diagnosis of Breast Cancer is of prime importance. Fine Needle Aspiration test or "FNA”, which has been used for several years in Europe, is a simple, inexpensive, noninvasive and accurate technique for detecting breast cancer. Expending the suitable features of the Fine Needle Aspiration results is the most important diagnostic problem in early stages of breast cancer. In this study, we introduced a new algorithm that can detect breast cancer based on combining artificial intelligent system and Fine Needle Aspiration (FNA). Methods We studied the Features of Wisconsin Data Base Cancer which contained about 569 FNA test samples (212 patient samples (malignant) and 357 healthy samples (benign)). In this research, we combined Artificial Intelligence Approaches, such as Evolutionary Algorithm (EA) with Genetic Algorithm (GA), and also used Exact Classifier Systems (here by Fuzzy C-Means (FCM)) to separate malignant from benign samples. Furthermore, we examined artificial Neural Networks (NN) to identify the model and structure. This research proposed a new algorithm for an accurate diagnosis of breast cancer. Results According to Wisconsin Data Base Cancer (WDBC) data base, 62.75% of samples were benign, and 37.25% were malignant. After applying the proposed algorithm, we achieved high detection accuracy of about "96.579%” on 205 patients who were diagnosed as having breast cancer. It was found that the method had 93% sensitivity, 73% specialty, 65% positive predictive value, and 95% negative predictive value, respectively. If done by experts, Fine Needle Aspiration (FNA) can be a reliable replacement for open biopsy in palpable breast masses. Evaluation of FNA samples during aspiration can decrease insufficient samples. FNA can be the first line of diagnosis in women with breast masses, at least in deprived regions, and may increase health standards and clinical supervision of patients. Conclusion Such a smart, economical, non-invasive, rapid

  4. Single-step reinforced microextraction of polycyclic aromatic hydrocarbons from soil samples using an inside needle capillary adsorption trap with electropolymerized aniline/multi-walled carbon nanotube sorbent.

    Science.gov (United States)

    Ghiasvand, Ali Reza; Yazdankhah, Fatemeh

    2017-03-03

    A polyaniline/multi-wall carbon nanotubes (PANI/MWCNT) composite was electrodeposited on the interior surface of a platinized stainless steel capillary needle and used to prepare an inside needle capillary adsorption trap (INCAT) device. The platinization expanded the interior adsorbing surface of the needle and made it more porous and cohesive for nanocomposite film. The nanocomposite was characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR). The fabricated INCAT was fixed into a cooling capsule to fabricate a cooling-assisted INCAT (CA-INCAT) system. The CA-INCAT device was used to extract polycyclic aromatic hydrocarbons (PAHs) from solid samples followed by gas chromatography-flame ionization detection (GC-FID) determination. To obtain the best extraction efficiency, the important experimental variables were studied and optimized. Under the optimal conditions, the limits of detection (LODs) for the studied PAHs were in the range of 0.002-0.02ngg -1 . Linear dynamic ranges (LDRs) for the calibration curves were found to be 0.1-30,000ngg -1 . Relative standard deviations (RSDs%) for six replicated analysis of 1ngg -1 PAHs were obtained 7.7-11%. The CA-INCAT-GC-FID method was successfully applied for the extraction and determination of PAHs in contaminated soil samples. The results were in agreement with those obtained by a validated ultrasound-assisted solvent extraction (UA-SE) method. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...... of the present study was to evaluate the role of EUS-FNA in isolated mediastinal lymphadenopathy in patients suspected of having tuberculosis....

  6. Incorporation of 13C labeled Pinus ponderosa needle and fine root litter into soil organic matter measured by Py-GC/MS-C-IRMS

    Science.gov (United States)

    Mambelli, S.; Gleixner, G.; Dawson, T. E.; Bird, J. A.; Torn, M. S.

    2006-12-01

    Developing effective strategies for enhancing C storage in soils requires understanding the influence of plant C quality. In turn, plant C quality impacts the decay continuum between plant residue and humified, stable SOM. This remains one of the least understood aspects of soil biogeochemistry. We investigated the initial phase of incorporation of 13C labeled Pinus ponderosa needle and fine root litter into SOM. The two litter types were placed in separate microcosms in the A horizon in a temperate conifer soil. Curie-point pyrolysis-gas chromatography coupled with on-line mass spectrometry and isotope ratio mass spectrometry (Py-GC/MS-C- IRMS) were used to determine the identity and the 13C enrichment of pyrolysis products (fragments of carbohydrates, lignin, proteins and lipids). We compared the two initial litter types, needles and fine roots, to samples of the bulk soil (A horizon, < 2mm) and soil humin fraction (from chemical solubility) obtained from each microcosm 1.5y after litter addition. Pyrolysis of plant material and SOM produced 56 suitable products for isotopic analysis; of them, 15 occurred in both the litter and bulk soil, 7 in both the litter and the humin fraction and 9 in both bulk soil and the humin fraction. The pyrolysis products found in common in the plant and soil were related either to polysaccharides or were non-specific and could have originated from various precursors. The data suggest that the majority of plant inputs, both from needles or fine roots, were degraded very rapidly. In the humin fraction, the most recalcitrant pool of C in soil, with a measured turnover time of 260y (this soil), only products from the fragmentation of polysaccharides and alkyl-benzene compounds were found. Comparisons of the enrichment normalized by input level suggest little difference between the incorporation of C from needles versus fine roots into SOM. The most enriched fragments in the humin fraction were products from polysaccharides degradation

  7. Effectiveness of Toyota process redesign in reducing thyroid gland fine-needle aspiration error.

    Science.gov (United States)

    Raab, Stephen S; Grzybicki, Dana Marie; Sudilovsky, Daniel; Balassanian, Ronald; Janosky, Janine E; Vrbin, Colleen M

    2006-10-01

    Our objective was to determine whether the Toyota Production System process redesign resulted in diagnostic error reduction for patients who underwent cytologic evaluation of thyroid nodules. In this longitudinal, nonconcurrent cohort study, we compared the diagnostic error frequency of a thyroid aspiration service before and after implementation of error reduction initiatives consisting of adoption of a standardized diagnostic terminology scheme and an immediate interpretation service. A total of 2,424 patients underwent aspiration. Following terminology standardization, the false-negative rate decreased from 41.8% to 19.1% (P = .006), the specimen nondiagnostic rate increased from 5.8% to 19.8% (P Toyota process change led to significantly fewer diagnostic errors for patients who underwent thyroid fine-needle aspiration.

  8. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  9. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    NARCIS (Netherlands)

    Konge, L.; Vilmann, P.; Clementsen, P.; Annema, J. T.; Ringsted, C.

    2012-01-01

    Background and study aims: Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was

  10. Learning curve of thyroid fine-needle aspiration biopsy.

    Science.gov (United States)

    Penín, Manuel; Martín, M Ángeles; San Millán, Beatriz; García, Juana

    2017-12-01

    Fine-needle aspiration biopsy (FNAB) is the reference procedure for thyroid nodule evaluation. Its main limitation are inadequate samples, which should be less than 20%. To analyze the learning curve of the procedure by comparing the results of a non-experienced endocrinologist (endocrinologist 2) to those of an experienced one (endocrinologist 1). Sixty FNABs were analyzed from February to June 2016. Each endocrinologist made 2punctures of every nodule in a random order. This order and the professional making every puncture were unknown to the pathologist who examined the samples. Endocrinologist 1 had a higher percentage of diagnoses than endocrinologist 2 (82% vs. 72%, P=.015). In the first 20 FNABs, the difference between both physicians was remarkable and statistically significant (80% vs. 50%, P=.047). In the following 20 FNABs, the difference narrowed and was not statistically significant (90% vs. 65%, P=.058). In the final 20 FNABs, the difference was minimal and not statistically significant (75% vs. 70%, P=.723). The learning curve of ultrasound-guided FNAB may be completed in a suitable environment by performing it at least 60 times. Although the guidelines recommend at least 3punctures per nodule, 2are enough to achieve an accurate percentage of diagnoses. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Aspergillus thyroiditis: first antemortem case diagnosed by fine-needle aspiration culture in a pediatric stem cell transplant patient.

    Science.gov (United States)

    Badawy, S M; Becktell, K D; Muller, W J; Schneiderman, J

    2015-12-01

    Aspergillus thyroiditis (AT) has historically been considered a postmortem diagnosis in immunocompromised patients; most have disseminated disease. This report summarizes the clinical challenge of diagnosing AT. It also highlights the value of the early use of thyroid fine-needle aspiration culture and the need for a high index of suspicion to reach the final diagnosis before disease dissemination. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  13. Diagnosis of multiple myeloma on based the material obtained by fine needle aspiration biopsy of the lungs

    Directory of Open Access Journals (Sweden)

    Bokun Radojka

    2004-01-01

    Full Text Available The patient presented in this paper was admitted to the hospital for the evaluation of radiologically revealed shadow in both lungs. In the course of diagnostic procedures, fine needle aspiration biopsy of the intrathoracic mass was performed. Cytologic analysis of the smear was performed because of clinical suspicion of plasma cell proliferative disease that was confirmed by bone marrow aspiration. Thus, the cytologic finding of intrathoracic lesion preceded the diagnosis of multiple myeloma.

  14. Implante subcutáneo de un carcinoma hepatocelular tras la punción aspiración con aguja fina Subcutaneous seeding of hepatocellular carcinoma after fine-needle percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    D. Martínez Ramos

    2007-06-01

    Full Text Available Los implantes subcutáneos son una complicación rara tras la punción aspiración con aguja fina de los carcinomas hepatocelulares. Los autores describen un caso de implante subcutáneo neoplásico en una mujer de 70 años con cirrosis hepática por virus C complicada con un carcinoma hepatocelular. Se efectuó una punción aspiración con aguja fina en el segmento II hepático. El implante tumoral se desarrolló en el trayecto de la punción aspiración. La tumoración subcutánea fue extirpada quirúrgicamente y el estudio anatomopatológico confirmó que se trataba de un carcinoma hepatocelular bien diferenciado.Subcutaneous tumor seeding after fine-needle percutaneous biopsy for hepatocellular carcinoma is a rarely seen complication. The authors describe a case of subcutaneous neoplastic seeding in a 70-year-old woman with chronic hepatitis C virus complicated by hepatocellular carcinoma. Ultrasonically guided fine-needle aspiration biopsy was performed in segment II of the liver. The neoplastic seeding developed along the needle track used to carry out the fine-needle biopsy. The subcutaneous tumor was excised, and histological examination revealed a well-differentiated hepatocellular carcinoma.

  15. The Utility of Endoscopic Ultrasound Guided Fine Needle Aspiration in the Diagnosis of Infectious Diseases—Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Mauro Ajaj Saieg

    2013-01-01

    Full Text Available Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA is a fast and minimally invasive methodology with a crucial impact on patients’ management. It has an important and established role in the diagnosis and staging of mediastinal and abdominal malignancies, but little is discussed in the literature on the usefulness of this technique in the diagnosis of infectious diseases. In the current report, we present three different cases where EUS was essential for reaching the diagnosis of tuberculosis and paracoccidiodomicosis in cases otherwise seen as malignant. In conclusion, EUS was successful not only in obtaining enough cells for morphological analysis, but also for the production of cell blocks and assessment of the presence of the microorganisms by special stains. EUS allied to fine needle biopsy was an important tool in determining diagnoses of enlarged lymph nodes, revealing the diagnosis of infectious diseases in cases otherwise seen as malignant. The wide use of this methodology in cases such as those reported here cannot only rule out malignancy, but also aid critically ill patients by installing early proper therapy without the need for aggressive interventions.

  16. Induction of parotitis by fine-needle aspiration in parotid Warthin's tumor.

    Science.gov (United States)

    Suzuki, Kensuke; Iwai, Hiroshi; Kaneko, Toshihiko; Sakaguchi, Mariko; Hoshino, Shoichi; Inaba, Muneo

    2009-08-01

    To estimate parotitis caused by fine-needle aspiration (FNA) in parotid Warthin tumor. Case series with chart review. Hospital records were reviewed for 104 parotid tumors (103 patients) including 35 Warthin tumors, which underwent FNA within our department. Three patients with four Warthin tumors among them noticed parotid pain, swelling, and abscess formation as a consequence of acute parotitis after FNA. Examinations of the materials obtained from tumor puncture or drainage before the start of antibiotic therapy showed no bacterial association in any patient. Two of the patients with Warthin tumor underwent parotidectomy, and the surgical specimens indicated histopathological changes with necrosis, abscess, granuloma, and the infiltration of inflammatory cells including Langhans-type multinucleated giant cells. It is conceivable that Warthin tumor bears the characteristics of inflammation induced by the FNA procedure without any relation to infection. Therefore, it may be better to avoid routine FNA and give priority to diagnostic imagings over FNA in the diagnosis of tumors strongly suspected as Warthin tumor.

  17. Fine needle aspiration cytology of vulvar actinomycosis masquerading clinically as malignancy

    Directory of Open Access Journals (Sweden)

    Rahul Parasram Wanjari

    2015-01-01

    Full Text Available Actinomycosis is a chronic infection caused by Actinomyces israelii, usually seen in immunocompromised patients or in the background of tissue injury. Vulvar actinomycosis presenting as a fixed swelling in an elderly individual can mimic malignancy and pose a diagnostic dilemma. We report here a case of vulvar actinomycosis diagnosed by fine needle aspiration (FNA. A 60-year-old postmenopausal female presented with a gradually increasing 15 cm × 10 cm vulvar swelling involving the right mons and right labia majora. The swelling was nodular, fixed, and nonulcerated, with multiple healed and few active discharging sinus tracts draining serosanguineous fluid and yellowish sulfur granules. FNA was diagnostic, as it revealed colonies of Actinomyces surrounded by polymorphs. Histopathology of excised specimen confirmed the cytological findings. FNA is an effective tool in the diagnosis of actinomycosis, although, its documentation is rare. Difficulties in the management can be avoided by early diagnosis using the FNA technique.

  18. Fine needle aspiration cytology of pseudosarcomatous reactive lesions of soft tissues: A report of two cases

    Directory of Open Access Journals (Sweden)

    Suchitha Satish

    2012-01-01

    Full Text Available Pseudosarcomatous lesions are reactive proliferative lesions of the soft tissue, that are likely to be misdiagnosed as malignant, based on clinical and histological features. The most common lesions are nodular fasciitis, proliferative fasciitis, proliferative myositis and myositis ossificans. These rapidly growing soft-tissue lesions can represent a variety of diagnoses involving radically different treatment modalities. Accurate diagnosis is important to avoid unnecessary and often mutilating surgery. We report two cases to illustrate the importance of correct identification of these lesions by fine needle aspiration cytology.

  19. Painless giant cell thyroiditis diagnosed by fine needle aspiration and associated with intense thyroidal uptake of gallium

    International Nuclear Information System (INIS)

    Sanders, L.R.; Moreno, A.J.; Pittman, D.L.; Jones, J.D.; Spicer, M.J.; Tracy, K.P.

    1986-01-01

    A 52-year-old woman presented with fever, goiter, and no evidence of pain or tenderness in the thyroid. A diagnosis of silent thyroiditis was made after obtaining evidence of biochemical thyrotoxicosis, intense gallium-67 citrate thyroidal localization, and cytologic thyroiditis. Fine needle aspiration biopsy of the thyroid revealed numerous giant cells in all areas of the thyroid, typical of subacute thyroiditis. This is believed to be the first time painless thyroiditis is reported with the classic cytologic feature of painful subacute thyroiditis

  20. Predictors of Malignancy and Recommended Follow-Up for Patients with Negative Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Suspected Pancreatic Lesions

    Directory of Open Access Journals (Sweden)

    Bret J Spier

    2009-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA can characterize and diagnose pancreatic lesions as malignant, but cannot definitively rule out the presence of malignancy. Outcome data regarding the length of follow-up in patients with negative or nondiagnostic EUS-FNA of pancreatic lesions are not well-established.

  1. Fine-needle aspiration cytology: its origin, development, and present status with special reference to a developing country, India.

    Science.gov (United States)

    Das, Dilip K

    2003-06-01

    Fine-needle aspiration cytology (FNAC) was performed on a large scale at Memorial Hospital, New York, during the 1930s, but during the ensuing years, it did not gain much encouragement in United States. The technique had a resurgence in Scandinavia during the 1950s and 1960s, where it flourished before spreading to other parts of the world. It had also a revival in the United States, which contributed enormously to this tool in each and every aspect. The status of FNA during 1966-2002 was assessed through review of MEDLINE search data on FNA and its correlation with World Bank website data on classification of countries. A total of 849 journals published 5,609 articles on FNA over a period of 37 years. Both the number of publishing journals and the number of published articles on FNA were low during the 1960s (3.5 +/- 0.58 and 4.0 +/- 0.82, respectively) and 1970s (20.3 +/- 14.72 and 25.0 +/- 20.54, respectively), but their number increased sharply from the 1980s onward (78.2 +/- 25.65 and 147.2 +/- 66.89, respectively, during the 1980s, 126.2 +/- 11.94 and 301.4 +/- 35.99, respectively, during the 1990s, and 113.3 +/- 36.46 and 287.3 +/- 85.93, respectively, during the 2000s). The difference between the decades of 1960s-2000s, with respect to the number of publishing journals and published articles, was highly significant (P big public sector hospitals, and even in private clinics and laboratories. The number of centers practicing FNAC increased sharply during 1980s, as evident from the response of 69 laboratories in various parts of India to a questionnaire. As of 1998, 55.9% of the laboratories performed >/=1,000 cases of FNA per year. In 46% of the centers, pathologists alone performed the FNAC, whereas in 51%, they performed it in collaboration with radiologists and surgeons. Disposable syringes and needles were used in all the centers, but syringe holders were used in only in 61% of centers. In 86% of laboratories, two or more routine stains were used, and

  2. Flow cytometric evaluation of peripheral blood and bone marrow and fine-needle aspirate samples from multiple sites in dogs with multicentric lymphoma.

    Science.gov (United States)

    Joetzke, Alexa E; Eberle, Nina; Nolte, Ingo; Mischke, Reinhard; Simon, Daniela

    2012-06-01

    To determine whether the extent of disease in dogs with lymphoma can be assessed via flow cytometry and to evaluate the suitability of fine-needle aspirates from the liver and spleen of dogs for flow cytometric examination. 44 dogs with multicentric B-cell (n = 35) or T-cell lymphoma (9) and 5 healthy control dogs. Procedures-Peripheral blood and bone marrow samples and fine-needle aspirates of lymph node, liver, and spleen were examined via flow cytometry. Logarithmically transformed T-cell-to-B-cell percentage ratio (log[T:B]) values were calculated. Thresholds defined by use of log(T:B) values of samples from control dogs were used to determine extranodal lymphoma involvement in lymphoma-affected dogs; results were compared with cytologic findings. 12 of 245 (5%) samples (9 liver, 1 spleen, and 2 bone marrow) had insufficient cellularity for flow cytometric evaluation. Mean log(T:B) values of samples from dogs with B-cell lymphoma were significantly lower than those of samples from the same site in dogs with T-cell lymphoma and in control dogs. In dogs with T-cell lymphoma, the log(T:B) of lymph node, bone marrow, and spleen samples was significantly higher than in control dogs. Of 165 samples assessed for extranodal lymphoma involvement, 116 (70%) tested positive via flow cytometric analysis; results agreed with cytologic findings in 133 of 161 (83%) samples evaluated via both methods. Results suggested that flow cytometry may aid in detection of extranodal lymphoma involvement in dogs, but further research is needed. Most fine-needle aspirates of liver and spleen were suitable for flow cytometric evaluation.

  3. Fine-needle aspiration and core biopsy in the diagnosis of breast lesions: A comparison and review of the literature

    Directory of Open Access Journals (Sweden)

    Suvradeep Mitra

    2016-01-01

    Full Text Available In recent times, the diagnosis of breast lesions has mostly become dependent on core needle biopsies (CNBs with a gradual reduction in the rate of performing fine-needle aspiration cytology (FNAC. Both the procedures have their pros and cons and outsmart each other taking into account different parameters. Both the methods are found to be fraught with loopholes, taking into account different performance indices, diagnostic accuracy and concordance, patient benefit, and cost-effectiveness. Unlike the popular belief of an absolute superiority of CNB over FNAC, the literature review does not reveal a very distinct demarcation in many aspects. We recommend judicious use of these diagnostic modalities in resource-limited settings and screening programs taking into account parameters such as palpability and availability of an experienced cytopathologist.

  4. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  5. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping, E-mail: yipingzhuang2010@sina.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Wang, Hai-Yan, E-mail: mycherishgirl@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Jin, E-mail: yari_zj@hotmail.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Feng, Yong, E-mail: fengyong119@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Lei, E-mail: motozl163@163.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China)

    2013-01-15

    Objective: CT-guided transthoracic biopsy is a well-established method in the cytologic or histologic diagnosis of pulmonary lesions. The knowledge of its diagnostic performance and complications for cavitary pulmonary lesions is limited. The purpose of this study was to determine the diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy (FNAB) in cavitary pulmonary lesions. Materials and methods: 102 consecutive patients with pulmonary cavitary lesions received CT-guided FNAB with use of an 18-gauge (n = 35) or 20-gauge (n = 67) Chiba for histology diagnosis. The sensitivity, specificity, and diagnostic accuracy of FNAB were calculated as compared with the final diagnosis. Complications associated with FNAB were observed. The diagnostic accuracy and complications were compared between patients with different lesion sizes and different cavity wall thickness. Results: The overall sensitivity, specificity, and accuracy of FNAB were 96.3%, 98.0%, and 96.1%, respectively. The sensitivity, specificity, and diagnosis accuracy in different lesion size (<2 cm vs ≥2 cm), or different cavity wall thickness (<5 mm vs ≥5 mm) were not different (P > 0.05; 0.235). More nondiagnostic sample was found in wall thickness <5 mm lesions (P = 0.017). Associated complications included pneumothorax in 9 (8.8%) patients and alveolar hemorrhage in 14 patients (13.7%) and hemoptysis in 1 patient (1%). No different rate of complications was found with regard to lesion size, wall thickness, length of the needle path and needle size (P > 0.05). Conclusion: CT-guided FNAB can be effectively ad safely used for patients with pulmonary cavitary lesions.

  6. Role of fine needle aspiration cytology and cell block in diagnosis of scar endometriosis: A case report

    Directory of Open Access Journals (Sweden)

    Sashibhusan Dash

    2015-01-01

    Full Text Available Presence of endometrial glands and stroma in places other than the uterus is called endometriosis. It can be pelvic or extra-pelvic. Abdominal scar endometriosis is an extra-pelvic endometriosis that can occur after surgery involving the uterus. Post-caesarean section, scar endometriosis is a rare event. The diagnosis is frequently made only after excision of disease tissue. We present a case of post-caesarean section abdominal scar endometriosis presenting as a tumor on the abdominal wall, which was diagnosed by fine needle aspiration cytology and confirmed by cell block preparation.

  7. Contribution of fine needle aspiration cytology (fnac) in the diagnosis of malignant thyroid noudles

    International Nuclear Information System (INIS)

    Baloch, M.N.; Ansari, A.; Maher, M.

    2008-01-01

    To analyze the efficacy of fine needle aspiration cytology (FNAC) in the initial evaluation of malignant solitary thyroid nodules. A total of 381 patients with solitary thyroid nodule, who were operated after FNAC. The data of all the patients was collected, and their preoperative FNAC reports were compared with the histopathological reports of their resected specimen. Thyroid cancer was confirmed postoperatively among 110(29%) patients of the study population. Out of the 255 patients who had benign FNAC findings, 10 were found to be malignant on histopathology reports. There were 5% false +ve and 7% false -ve results. FNAC of the thyroid gland is sensitive, specific, accurate, rapid, minimally invasive and cost effective. It is the first line procedure in the evaluation of thyroid nodules. (author)

  8. Intratumor genetic heterogeneity of breast carcinomas as determined by fine needle aspiration and TaqMan low density array

    DEFF Research Database (Denmark)

    Lyng, Maria B.; Laenkholm, Anne-Vibeke; Pallisgaard, Niels

    2007-01-01

    BACKGROUND: Gene expression profiling is thought to be an important tool in determining treatment strategies for breast cancer patients. Tissues for such analysis may at a preoperative stage be obtained, by fine needle aspiration (FNA) allowing initiation of neoadjuvant treatment. To evaluate the...... of breast carcinomas, as sampled by FNA, does not prohibit generation of useful gene profiles for treatment decision making. However, sampling and analysis strategies should take heterogeneity within a tumor, and varying heterogeneity amongst the single genes, into account...

  9. Fine needle aspiration cytology in feline skeletal muscle as a diagnostic tool for extramedullary plasmacytoma

    Directory of Open Access Journals (Sweden)

    D.B. Martins

    Full Text Available ABSTRACT Extramedullary noncutaneous plasmacytoma (ENP is a myeloproliferative disorder of plasma cells that rarely affects cats. This paper describes an ENP case revealed by fine needle aspiration cytology (FNAC of the mass in the skeletal muscle of an 8-month-old, male, mixed breed cat, which had a nodule in the left hind limb. The rapid immunoassay test confirmed the presence of feline leukemia virus (FeLV. The animal necropsy macroscopically showed the nodule came from the semimembranosus muscle. Histopathological examination ratified the cytological findings. Thus, this paper alerts to the existence of plasmacytoma located in the skeletal muscle of feline species. FNAC is a quick and efficient method for diagnosis of ENP.

  10. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  11. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  12. Acquired myospherulosis secondary to gluteal augmentation on fine needle aspiration cytology: A diagnostic challenge.

    Science.gov (United States)

    Alperstein, Susan; Dilcher, Thomas; Viswanathan, Kartik; Rao, Rema A; Siddiqui, Momin T; Giorgadze, Tamara

    2018-05-01

    A 30-year-old female presented with a three-month history of a multilocular cystic lesion over the lumbosacral spine. Fine-needle aspiration biopsy (FNA) of the lesion was performed at an outside institution, and a cytologic diagnosis, suspicious for chordoma, was rendered. The patient presented for surgical consultation at our institution. Repeat FNA demonstrated an unusual fat-like material. Upon further inquiry, the patient provided a recent history of gluteal contour improvement with fibroadipose tissue implants. A diagnosis of myospherulosis was made with a concurrent surgical pathology correlation. No evidence of chordoma was identified. To date, this is the first reported case of acquired myospherulosis in the context of gluteal contour enhancement and represents an important diagnostic pitfall to consider on cytology preparations. © 2017 Wiley Periodicals, Inc.

  13. Toward improving fine needle aspiration cytology by applying Raman microspectroscopy

    Science.gov (United States)

    Becker-Putsche, Melanie; Bocklitz, Thomas; Clement, Joachim; Rösch, Petra; Popp, Jürgen

    2013-04-01

    Medical diagnosis of biopsies performed by fine needle aspiration has to be very reliable. Therefore, pathologists/cytologists need additional biochemical information on single cancer cells for an accurate diagnosis. Accordingly, we applied three different classification models for discriminating various features of six breast cancer cell lines by analyzing Raman microspectroscopic data. The statistical evaluations are implemented by linear discriminant analysis (LDA) and support vector machines (SVM). For the first model, a total of 61,580 Raman spectra from 110 single cells are discriminated at the cell-line level with an accuracy of 99.52% using an SVM. The LDA classification based on Raman data achieved an accuracy of 94.04% by discriminating cell lines by their origin (solid tumor versus pleural effusion). In the third model, Raman cell spectra are classified by their cancer subtypes. LDA results show an accuracy of 97.45% and specificities of 97.78%, 99.11%, and 98.97% for the subtypes basal-like, HER2+/ER-, and luminal, respectively. These subtypes are confirmed by gene expression patterns, which are important prognostic features in diagnosis. This work shows the applicability of Raman spectroscopy and statistical data handling in analyzing cancer-relevant biochemical information for advanced medical diagnosis on the single-cell level.

  14. Fine needle aspiration cytology: sensitivity and specificity in thyroid lesions

    International Nuclear Information System (INIS)

    Musani, M.A.; Khan, F.A.; Malik, S.; Khambaty, Y.

    2011-01-01

    Background: Thyroid enlargement is one of the common problems in patients presenting at outpatients department of ENT particularly in females. Thyroid nodules are common, thyroid cancer is uncommon and the most common way for it to present is as a solitary thyroid nodule. This study was conducted to evaluate the sensitivity and specificity of Fine Needle Aspiration Cytology (FNAC) in thyroid diseases. Method: This prospective analytic study was conducted at ENT Department of Karachi Medical and Dental College/Abbasi Shaheed Hospital during year 2004-8. One hundred and five cases were enrolled who underwent thyroid surgery after complete evaluation by history, clinical examination, Thyroid profile, Thyroid Scintigraphy, Ultrasound neck and FNAC. In cases which were revealed malignant by FNAC, CT scan were done to see the extent of disease and neck node status. Surgery was done in all cases and specimens sent for histopathology. Results: Male to female ratio of the patients was 1:8.5. Most common lesion was benign nodule (96). Malignant lesions were 9 in FNAC. In histopathology, the benign nodules were 92, and malignant cases were 13. Sensitivity of FNAC was 61.53% and specificity was 98.9%. Conclusion: FNAC in Thyroid has high sensitivity and specificity. (author)

  15. Enhanced Visualization of Fine Needles Under Sonographic Guidance Using a MEMS Actuator

    Directory of Open Access Journals (Sweden)

    Zhiyuan Shen

    2015-01-01

    Full Text Available Localization of a needle tip is important for biopsy examinations in clinics. However, the needle tip is sometimes difficult to discern under the guidance of sonography due to its poor visibility. A mini actuator that radiates a low-intensity ultrasound wave was manufactured using micro-electro-mechanical system (MEMS technology. Interference between the radiated and diagnostic ultrasound pulses was observed as bright lines in the B-mode ultrasound image, from which the mini actuator could be recognized with ease. Because the distance between the mini actuator and the needle tip is fixed, the needle tip can be determined despite its inconsistent appearance in the sonography. Both gel phantom and ex vivo tissue evaluation showed that the needle tip can be determined reliably utilizing the acoustic interference pattern.

  16. Ultrasound-guided fine needle aspiration of thyroid nodules: A consensus statement by the Korean Society of Thyroid Radiology

    International Nuclear Information System (INIS)

    Lee, Young Hen; Baek, Jung Hwan; Jung, So Lyoung; Kwak, Jin Young; Kim, Ji Hoon; Shin, Jung Hee

    2015-01-01

    Ultrasound (US)-guided fine needle aspiration (US-FNA) has played a crucial role in managing patients with thyroid nodules, owing to its safety and accuracy. However, even with US guidance, nondiagnostic sampling and infrequent complications still occur after FNA. Accordingly, the Task Force on US-FNA of the Korean Society of Thyroid Radiology has provided consensus recommendations for the US-FNA technique and related issues to improve diagnostic yield. These detailed procedures are based on a comprehensive analysis of the current literature and from the consensus of experts.

  17. Sapphire capillary interstitial irradiators for laser medicine

    Science.gov (United States)

    Shikunova, I. A.; Dolganova, I. N.; Dubyanskaya, E. N.; Mukhina, E. E.; Zaytsev, K. I.; Kurlov, V. N.

    2018-04-01

    In this paper, we demonstrate instruments for laser radiation delivery based on sapphire capillary needles. Such sapphire irradiators (introducers) can be used for various medical applications, such as photodynamic therapy, laser hyperthermia, laser interstitial thermal therapy, and ablation of tumors of various organs. Unique properties of sapphire allow for effective redistribution of the heat, generated in biological tissues during their exposure to laser radiation. This leads to homogeneous distribution of the laser irradiation around the needle, and lower possibility of formation of the overheating focuses, as well as the following non-transparent thrombi.

  18. Thyroid Fine-Needle Aspiration Cytology Practice in Korea

    Directory of Open Access Journals (Sweden)

    Yoon Jin Cha

    2017-11-01

    Full Text Available We reviewed the current status of thyroid fine-needle aspiration cytology (FNAC in Korea. Thyroid aspiration biopsy was first introduced in Korea in 1977. Currently, radiologists aspirate the thyroid nodule under the guidance of ultrasonography, and cytologic interpretation is only legally approved when a cytopathologist makes the diagnosis. In 2008, eight thyroid-related societies came together to form the Korean Thyroid Association. The Korean Society for Cytopathology and the endocrine pathology study group of the Korean Society for Pathologists have been updating the cytologic diagnostic guidelines. The Bethesda System for Reporting Thyroid Cytopathology was first introduced in 2009, and has been used by up to 94% of institutions by 2016. The average diagnosis rates are as follows for each category: I (12.4%, II (57.9%, III (10.4%, IV (2.9%, V (3.7%, and VI (12.7%. The malignancy rates in surgical cases are as follows for each category: I (28.7%, II (27.8%, III (50.6%, IV (52.3%, V (90.7%, and VI (100.0%. Liquid-based cytology has been used since 2010, and it was utilized by 68% of institutions in 2016. The categorization of thyroid lesions into “atypia of undetermined significance” or “follicular lesion of undetermined significance” is necessary to draw consensus in our society. Immunocytochemistry for galectin-3 and BRAF is used. Additionally, a molecular test for BRAF in thyroid FNACs is actively used. Core biopsies were performed in only 44% of institutions. Even the institutions that perform core biopsies only perform them for less than 3% of all FNACs. However, only 5% of institutions performed core biopsies up to three times more than FNAC.

  19. Fine-needle aspiration cytology in children with superficial lymphadenopathy

    Directory of Open Access Journals (Sweden)

    F. De Corti

    2014-04-01

    Full Text Available Introduction: In pediatric population Fine-Needle Aspiration Citology (FNAC is slowly gaining acceptance in clinical management of Superficial Lymphadenopathy (SL. Our experience adds some data about the usefulness of this technique in diagnosing the cause of a SL and therefore guiding further treatment. Patients and Methods: 238 FNAC were performed in 217 patients with SL, observed at our Institution from 2002 to 2006. The neck was the most frequent localization. The results were available within few hours. In cases of granulomatous findings, the samples were processed for microbiological and PCR test, in order to identify Mycobacteria. Results: 174 were reactive lesions, 38 granulomatous lymphadenopathies, 24 malignant lesions, 2 specimens inadequate for diagnosis. Among the 174 reactive SL, 22 required an incisional biopsy after 1 month follow-up. Among the granulomatous lymphadenopathies, 13 children with Cat-Scratch Disease recovered, 25 with Mycobacteria infection underwent surgical excision. For 24 malignant lesions, the diagnosis was confirmed by further biopsy. Two false negative and no false positive were detected (sensitivity 92%, specificity 100%. No complications were encountered. Conclusions: In our experience FNAC, performed by experienced cytopathologist, has revealed to be a fast, safe, non invasive and inexpensive method to achieve diagnosis in persistent SL. The use of FNAC gave us the possibility to select patients for further investigation and/or surgical treatment. Incisional biopsy remains necessary to confirm the diagnosis in case of malignancy or doubtful lesions.

  20. The effects of timing of fine needle aspiration biopsies on gene expression profiles in breast cancers

    International Nuclear Information System (INIS)

    Wong, Vietty; Wang, Dong-Yu; Warren, Keisha; Kulkarni, Supriya; Boerner, Scott; Done, Susan Jane; Leong, Wey Liang

    2008-01-01

    DNA microarray analysis has great potential to become an important clinical tool to individualize prognostication and treatment for breast cancer patients. However, with any emerging technology, there are many variables one must consider before bringing the technology to the bedside. There are already concerted efforts to standardize protocols and to improve reproducibility of DNA microarray. Our study examines one variable that is often overlooked, the timing of tissue acquisition, which may have a significant impact on the outcomes of DNA microarray analyses especially in studies that compare microarray data based on biospecimens taken in vivo and ex vivo. From 16 patients, we obtained paired fine needle aspiration biopsies (FNABs) of breast cancers taken before (PRE) and after (POST) their surgeries and compared the microarray data to determine the genes that were differentially expressed between the FNABs taken at the two time points. qRT-PCR was used to validate our findings. To examine effects of longer exposure to hypoxia on gene expression, we also compared the gene expression profiles of 10 breast cancers from clinical tissue bank. Using hierarchical clustering analysis, 12 genes were found to be differentially expressed between the FNABs taken before and after surgical removal. Remarkably, most of the genes were linked to FOS in an early hypoxia pathway. The gene expression of FOS also increased with longer exposure to hypoxia. Our study demonstrated that the timing of fine needle aspiration biopsies can be a confounding factor in microarray data analyses in breast cancer. We have shown that FOS-related genes, which have been implicated in early hypoxia as well as the development of breast cancers, were differentially expressed before and after surgery. Therefore, it is important that future studies take timing of tissue acquisition into account

  1. Fine-needle aspiration cytology of mucous retention cyst of the tongue: distinction from other cystic lesions of the tongue.

    Science.gov (United States)

    De Las Casas, L E; Bardales, R H

    2000-05-01

    Mucous retention cyst (MRC) is a common submucosal lesion of the oral cavity that, when deeply seated, simulates a neoplasm. This report describes the fine-needle aspiration cytology findings of a lingual MRC of complex architecture and with metaplastic epithelium. In addition, we emphasize its cytologic differential diagnosis from other benign and malignant cystic lesions of the tongue. To the best of our knowledge, this is the first report of aspiration cytology of a complex MRC of the tongue. Copyright 2000 Wiley-Liss, Inc.

  2. Cytology of primary vaginal melanoma: An unusual report on fine needle aspiration.

    Science.gov (United States)

    Agarwal, Poojan; Kaushal, Manju

    2017-03-01

    Primary malignant melanoma of the vagina is an extremely uncommon malignancy comprising of less than 10% malignancies of the female genital tract and 0.3% of all melanomas. Melanoblasts are neural crest derivatives and are notorious for causing primary cutaneous neoplasms. However, they involve virtually every organ of the body including eye, intestines and ocular mucosa, probably due to aberrancies in cell migration. Vagina is a rare site and primary melanoma of the vagina occurs in postmenopausal women with vaginal discharge, bleeding, or mass as common presenting complaints. Only a handful of case reports are available describing this entity on biopsy and PAP smear samples; however, fine needle aspiration has seldom been discussed. In the present report we discuss a case of an elderly female who complained of mass protruding through the vaginal opening, FNAC was done from the mass as well as from the right inguinal lymph node. An extensive clinicoradiological workup, and immunohistochemical confirmation is essential to rule out metastatic lesions and confirm primary. Diagn. Cytopathol. 2017;45:252-256. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer

    DEFF Research Database (Denmark)

    Konge, Lars; Vilmann, P; Clementsen, P

    2012-01-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliabilit...... and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC....

  4. Cancer cell profiling by barcoding allows multiplexed protein analysis in fine-needle aspirates.

    Science.gov (United States)

    Ullal, Adeeti V; Peterson, Vanessa; Agasti, Sarit S; Tuang, Suan; Juric, Dejan; Castro, Cesar M; Weissleder, Ralph

    2014-01-15

    Immunohistochemistry-based clinical diagnoses require invasive core biopsies and use a limited number of protein stains to identify and classify cancers. We introduce a technology that allows analysis of hundreds of proteins from minimally invasive fine-needle aspirates (FNAs), which contain much smaller numbers of cells than core biopsies. The method capitalizes on DNA-barcoded antibody sensing, where barcodes can be photocleaved and digitally detected without any amplification steps. After extensive benchmarking in cell lines, this method showed high reproducibility and achieved single-cell sensitivity. We used this approach to profile ~90 proteins in cells from FNAs and subsequently map patient heterogeneity at the protein level. Additionally, we demonstrate how the method could be used as a clinical tool to identify pathway responses to molecularly targeted drugs and to predict drug response in patient samples. This technique combines specificity with ease of use to offer a new tool for understanding human cancers and designing future clinical trials.

  5. Pancreatic metastasis in a case of small cell lung carcinoma: Diagnostic role of fine-needle aspiration cytology and immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Dilip K Das

    2011-01-01

    Full Text Available Small cell lung carcinoma represents a group of highly malignant tumors giving rise to early and widespread metastasis at the time of diagnosis. However, the pancreas is a relatively infrequent site of metastasis by this neoplasm, and there are only occasional reports on its fine needle aspiration (FNA cytology diagnosis. A 66-year-old man presented with extensive mediastinal lymphadenopathy and a mass in the pancreatic tail. Ultrasound-guided FNA smears from the pancreatic mass contained small, round tumor cells with extensive nuclear molding. The cytodiagnosis was metastatic small cell carcinoma. Immunocytochemical staining showed that a variable number of neoplastic cell were positive for cytokeratin, chromogranin A, neurone-specific enolase and synaptophysin but negative for leukocyte common antigen. The trans-bronchial needle aspiration was non-diagnostic, but biopsy was suspicious of a small cell carcinoma. This case represents a rare metastatic lesion in the pancreas from small cell lung carcinoma, diagnosed by FNA cytology.

  6. Fine needle aspiration biopsy proves increased T-lymphocyte proliferation in tumor and decreased metastatic infiltration after treatment with doxorubicin bound to PHPMA copolymer carrier

    Czech Academy of Sciences Publication Activity Database

    Betka, Jaroslav; Hovorka, Ondřej; Bouček, Jan; Ulbrich, Karel; Etrych, Tomáš; Říhová, Blanka

    2013-01-01

    Roč. 21, č. 7 (2013), s. 648-661 ISSN 1061-186X R&D Projects: GA ČR GAP301/12/1254 Institutional support: RVO:61388971 ; RVO:61389013 Keywords : Doxorubicin conjugates * Drug targeting * Fine needle aspiration biopsy Subject RIV: EE - Microbiology, Virology; CD - Macromolecular Chemistry (UMCH-V) Impact factor: 2.723, year: 2013

  7. Extramedullary plasmacytoma of thyroid - a mimicker of medullary carcinoma at fine needle aspiration cytology: A case report

    Directory of Open Access Journals (Sweden)

    Vidya Bhat

    2014-01-01

    Full Text Available A rare case of extra medullary plasmacytoma (EMP of thyroid gland in a 60 year old male, occurring against a background of Hashimoto′s thyroiditis is reported. The fine needle aspiration cytology (FNAC initially done as an outpatient procedure, showed atypical epithelial cells on a background of amyloid. Considering these findings we gave a diagnosis of medullary carcinoma. Histology of the total thyroidectomy specimen showed an extensive infiltration of neoplastic plasma cells against a background of Hashimoto′s thyroiditis, with a bizarre Hurthle cell change. Immunohistochemistry on the histology sections confirmed the diagnosis of solitary plasmacytoma of thyroid against a background of Hashimoto′s thyroiditis.

  8. Breeding soundness evaluation of bulls by semen analysis, testicular fine needle aspiration cytology and trans-scrotal ultrasonography

    Directory of Open Access Journals (Sweden)

    Chapwanya A

    2008-05-01

    Full Text Available Abstract The aim of this study was to evaluate the usefulness of trans-scrotal ultrasonography and testicular fine needle aspiration cytology in assessing bulls for breeding suitability. These two techniques were also compared with semen analysis. Bulls presented for breeding soundness evaluation were assessed using all three techniques. The findings of each technique were compared. There was agreement in classification of fertile bulls using all three techniques, suggesting that the combined use of these techniques enhances routine breeding soundness examination. Use of the three techniques also enhances detailed investigation of suspected sub-fertile bulls while accurately identifying testicular cause(s of sire sub-fertility.

  9. The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients

    Directory of Open Access Journals (Sweden)

    Jens Kristjan GUDMUNDSSON

    Full Text Available ABSTRACT Objective Fine-needle aspiration cytology is a valuable method for preoperative assessment of head and neck tumors. However, its accuracy in detection of salivary gland masses is controversial compared with other methods. The aim of this work was to evaluate the effectiveness and accuracy of fine-needle aspiration cytology (FNAC in the diagnosis of parotid gland masses. Material and Methods Over a 10-year period, 126 parotid gland masses were resected. Retrospective chart reviews of 114 patients were performed. The results of FNAC and final histological diagnosis were compared and the accuracy of FNAC was determined. Results Final histological evaluation revealed 11 malignant tumors and 103 benign lesions. Pleomorphic adenoma was the most common neoplasm (63%, followed by Warthin’s tumor (17.5%. The sensitivity of FNAC in detecting malignant tumors was 73% and the specificity was 97%. Positive predictive value (PPV was 73% and negative predictive value (NPV was 97%. The overall accuracy of FNAC in detecting parotid masses was 95%. False-negative diagnosis was found in mucoepidermoid carcinoma, acinic cell carcinoma, and epithelial-myoepithelial carcinoma whereas there was false-positive diagnosis in cases of pleomorphic adenoma and normal parotid gland tissue. Conclusion FNAC is a reliable minimally invasive diagnostic method with a high sensitivity in diagnosis of lesions in parotid glands. The sensitivity of detection of malignant tumors in parotid glands was low due to the biopsy technique used, and depended on tumor location. Postoperative complications decreased after superficial parotidectomy.

  10. Giant cell tumor of soft tissues of low malignant potential: A rare diagnosis on fine needle aspiration cytology

    Directory of Open Access Journals (Sweden)

    Maithili M Kulkarni

    2016-01-01

    Full Text Available Primary giant cell tumors of soft tissues (GCT-ST are extremely rare soft tissue tumors, located in both superficial and deep soft tissues. They resemble osseous giant cell tumors morphologically and immunohistochemically. The tumor exhibits strong positive immunoreactivity for cluster of differentiation 68 (CD68 within multinucleated osteoclast-like giant cells and focal staining of mononuclear cells. Case reports describing the cytohistological features of this entity are very few. We report a case of GCT-ST of low malignant potential diagnosed on fine needle aspiration (FNA and confirmed on histological and immunohistochemical studies.

  11. Cytological and sonographic correlation of the biopsies by fine needle aspiration (FNAB) of thyroid nodules in the Hospital San Rafael de Alajuela of July 1, 2006 to February 28, 2007

    International Nuclear Information System (INIS)

    Barrantes Vega, Jesus

    2007-01-01

    The importance of the use of aspiration biopsy with ultrasonic-guided fine needle is recognized as screening method for diagnosis of thyroid nodules. Thyroid nodules are very common, the prevalence of palpitation has been estimated by 4% and 6% by ultrasound. The prevalence in autopsy data of patients with no history of thyroid pathology has been up to 50%. The use set of advanced imaging techniques and modified techniques of biopsy is implemented in order to increase the diagnostic security of thyroid lesions. The incidental finding of thyroid nodules or incidentalomas has soared dizzily, since the advent of ultrasound as an element in the valuation of thyroid disease and thyroid in the neck. Incidence has been reported even up to 40%. A growing number of endocrinologists are using aspiration biopsy with ultrasound guided fine needle of thyroid nodules as initial diagnostic procedure to identify discrete nodules with a direct location. The percentage of malignant nodules or that require surgery by size or symptomatology, generally, is very low, had to be established a systematic approach to reducing morbidity and mortality associated with major surgery of the neck and reduce costs. The biopsy by fine needle aspiration has been a well established diagnostic technique for preoperative evaluation of thyroid nodules, which has led a significant reduction in the number of unnecessary surgeries in most centers has been between 35-75%. This biopsy has been a specific method, sensitive and inexpensive. The sonographic guidance for biopsy by fine needle aspiration offers the following benefits: is safe and inexpensive, able to reduce costs in 25%, minimally invasive and highly effective, this guidance has increased the detection of malignancy of 14 to 39%. Among the complications that can occur is the formation of hematoma and pain, which are rare. On the other hand, the sonographic guidance is essential for biopsy nonpalpable nodules helping to ensure proper placement of

  12. Diagnose of the prostate cancer: Utility of the antigen specifies of prostate, transrectal echography and aspired by fine needle

    International Nuclear Information System (INIS)

    De Nubbila, Eduardo; Rosillo, Marco; Fals, Orlando

    1993-01-01

    We describe three improved methods of detecting prostate cancer while it is still confined to the gland: Prostrate specific antigen (PSA), trans-rectal ultrasound (TRUS) and trans-rectal ultrasound-directed prostatic fine needle aspirate (TRFNA). Of a total of 60 studied cases, 23 cytological procedures were done, and half of these were found to have prostate cancer. We compare traditional methods like digital rectal examination and prostatic phosphatase acid with PSA and TRFNA. We conclude that these methods increase the sensibility and specificity of early prostate cancer detection

  13. Safety and correlation of test results of combined ultrasound-guided fine-needle aspiration and needle core biopsy of the canine spleen.

    Science.gov (United States)

    Watson, Adam T; Penninck, Dominique; Knoll, Joyce S; Keating, John H; Sutherland-Smith, James

    2011-01-01

    The safety and diagnostic value of combined splenic fine-needle aspiration (FNA) and needle core biopsy (NCB) is unknown. Forty-one dogs with splenic lesions were studied prospectively. Safety was assessed in 38 dogs and no complications were encountered. Initially, clinical and anatomic pathologists reviewed each FNA and NCB sample, respectively, without knowledge of the other's results. Diagnoses were categorized as neoplastic, benign, inflammatory, normal, or nondiagnostic. The level of agreement between sampling methods was categorized as complete, partial, disagreement, or not available. Test correlation was performed in 40 dogs. Nondiagnostic results occurred in 5/40 NCB (12.5%) and no FNA samples. Neoplasia was diagnosed in 17/40 dogs (42.5%), benign changes in 20/40 dogs (50%), inflammatory disorders in 0/40 dogs, and normal 2/40 dogs (5%). One of the 40 dogs (2.5%) had a diagnosis that was equivocal for neoplasia on both tests and therefore was not categorized. Of the 35 dogs that had diagnostic samples, cytopathologic and histopathologic diagnoses agreed completely in 18/35 dogs (51.4%), partially in 3/35 dogs (8.6%), and were in disagreement in 14/35 dogs (40.0%). Pathologists collaboratively reviewed diagnoses that were in disagreement or partial agreement and altered their individual diagnoses in 6/17 dogs (35.3%) to be within partial or complete agreement, respectively. Percutaneous FNA and NCB can be performed safely in dogs with sonographic splenic changes. Results suggest that adding NCB to FNA provides complementary information in dogs with suspected splenic neoplasia. This combined protocol may improve detection of splenic neoplasia and provide neoplastic subclassification. © 2010 Veterinary Radiology & Ultrasound.

  14. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  15. Diagnosis of disseminated candidiasis by fine needle aspiration of lymph node and by splenic imprint in a patient with acute promyelocytic leukemia.

    Science.gov (United States)

    Chao, T Y; Chang, J Y; Yu, C Y; Tsao, T Y

    1995-01-01

    Cytologic studies were done on fine needle aspirates of the lymph node and imprints of splenic biopsies from a patient with acute promyelocytic leukemia who was febrile while being treated with chemotherapy. Examination of the lymph node aspirates revealed pus and numerous pseudohyphae which were later identified as Candida tropicalis. When multiple nodular lesions were detected in the spleen by abdominal sonography and CT scan, needle biopsy of the spleen was done. Cytologic examination of touch imprints of the biopsy disclosed intracellular fungal blastospores. The patient was treated with and responded well to amphotericin B and 5-fluorocytosine. As a result of our experience with this patient we emphasize the importance of close incorporation of clinical information and diagnostic cytology. With such a cooperation, cytologic studies become a most useful method for diagnosis.

  16. Use of fine needle aspirate from peripheral nerves of pure-neural leprosy for cytology and PCR to confirm the diagnosis: A pilot study

    Directory of Open Access Journals (Sweden)

    Abu Hena Hasanoor Reja

    2013-01-01

    Full Text Available Background: The diagnosis of pure neural leprosy (PNL remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC coupled with Ziehl Neelsen staining (ZN staining and Multiplex- Polymerase Chain Reaction (PCR specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL, which may be simpler and yet reliable. Aim: The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Methods: Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex- PCR. Results: Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4% with the help of conventional acid-fast staining and 11 cases (84.6% with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23% cases showed specific epithelioid cells, whereas 8 (61.5% cases showed non-specific inflammation, and 2 (15.3% cases had no inflammatory cells. Conclusion: Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of

  17. The value of fine needle aspiration and cytologic examination of impalpable complicated breast cysts.

    Science.gov (United States)

    Tez, Selda; Dener, Cenap; Köktener, Aslý; Caydere, Muzaffer; Tez, Mesut

    2008-01-01

    The purpose of the study was to evaluate the utility of fine needle aspiration--FNA and cytologic analysis of impalpable complicated breast cysts. We rewieved the imaging findings, aspiration, cytology and biopsy results and followup imaging findings of 246 complicated cysts in 166 women retrospectively. FNA was performed in 169 out of the 246 complicated cysts. Thirtyone lesions were followed-up with US. Surgical biopsy was performed from five lesions. No malignant cells (137 cysts), insufficient cellular material (17 cysts), atypical cells (4 cysts) were seen in cytological examination of the aspirates. None of these lesions were found to represent malignancy at the time of surgical excision and during follow-up. Impalpable complicated breast cysts may be classified as probably benign and can be managed with follow-up imaging studies instead of intervention. Routine cytologic examination is unnecessary if the fluid is not bloody (Tab. 2, Ref. 18). Full Text (Free, PDF) www.bmj.sk.

  18. Fine needle aspiration cytology diagnosis of metastatic malignant diffuse type tenosynovial giant cell tumor

    Directory of Open Access Journals (Sweden)

    Prashant Ramteke

    2017-01-01

    Full Text Available Tenosynovial giant cell tumors (TGCTs arise from the synovium of joint, bursa, and tendon sheath, and are classified into localized and diffuse types. Diffused type often affects the large joint, and has more recurrence, metastasis, and malignant transformation potential compared to the localized type. Malignant diffused TGCT (D-TGCT usually occurs as a large tumor (>5 cm, in older patients, and its histopathologic features include necrosis, cellular anaplasia, prominent nucleoli, high nuclear cytoplasmic ratio, brisk mitosis, discohesion of tumor cells, paucity of giant cells, and a diffuse growth pattern. At least five of these criteria are required for the histopathologic diagnosis of malignant TGCT because the benign TGCT also shares many of these morphological features. We describe the cytomorphologic features of a malignant D-TGCT from an unusual case of pulmonary metastasis in an adult patient. Fine needle aspiration cytologic features of malignant D-TGCT have not been described earlier in the English literature.

  19. Fine-Needle Aspiration Cytology of Parathyroid Carcinoma Mimic Hürthle Cell Thyroid Neoplasm

    Directory of Open Access Journals (Sweden)

    Chutintorn Sriphrapradang

    2014-01-01

    Full Text Available Background. Fine-needle aspiration (FNA can cause misdiagnosis of cytomorphological findings between parathyroid and thyroid lesions. Case Presentation. A 31-year-old man presented with a palpable neck mass on the right thyroid lobe. FNA cytology was reported as intrathyroidal lymphoid hyperplasia. After 5 years, repeated FNA was done on the enlarged nodule with result of Hürthle cell lesion. Prior to right lobectomy, laboratories revealed elevated serum calcium and parathyroid hormone (PTH. Careful history taking revealed chronic knee pain and ossifying fibroma at the maxilla. Ultrasonography showed a 2.8 cm mass inferior to right thyroid lobe. Pathology from en bloc resection was parathyroid carcinoma and immunohistochemical study revealed positivity for PTH. Genetic analysis found somatic mutation of CDC73 gene in exon1 (c.70delG which caused premature stop codon in amino acid 26 (p.Glu24Lysfs2*. The final diagnosis was hyperparathyroidism-jaw tumor syndrome. Conclusions. FNA cytology of parathyroid can mimic thyroid lesion. It is important to consider and correlate the entire information from clinical history, laboratory, imaging, and FNA.

  20. How accurate can we diagnose breast lesion by fine needle aspiration cytology?

    International Nuclear Information System (INIS)

    Okada, Toshihiro; Ito, Kenichi; Uehara, Tsuyoshi

    2011-01-01

    Fine needle aspiration cytology (FNA) is performed firstly in the diagnosis of breast lesion, as the FNA is less-invasive diagnostic procedure. Depending on the results obtained by the FNA, we subsequently perform core needle biopsy or Mammotome biopsy to determine the histological finding of the breast lesion. The purpose of the study is to evaluate the accuracy and limitation of diagnosis of breast lesion by FNA. The clinical data of 528 patients who underwent an operation for the breast lesion in the Shinshu University hospital from April 2004 to March 2009 were analyzed. Of 528 breast lesions, 488 were breast cancers, and 40 benign breast lesions. Of 528 breast lesions, 94 cases were excluded because CNB or MMT was performed firstly. In these cases, some were scheduled for the preoperative chemotherapy, and others were highly suspected to be ductal carcinoma in situ (DCIS), which was expected to be difficult to be diagnosed by FNA. Two hundreds and ninety two cases of 488 (59.8%) breast cancers and 21 of 40 (52.2%) benign lesions were diagnosed by FNA, respectively. Three of 299 cases (1%) determined to be 'malignant' by FNA were diagnosed as benign in the postoperative pathological diagnosis. 40 of 40 'suspicious for malignancy,' 40 of 46 'indeterminate,' 12 of 38 'normal or benign,' and 10 of 11 'inadequate' cases were finally diagnosed as cancer, in which scirrhous carcinoma, DCIS, small papillo-tubular carcinoma and lobular carcinoma were observed. It is speculated that enough specimens for diagnosis might not be obtained from these tumors by FNA, and that diagnosis by cytology itself might be difficult for these tumors. Although FNA is useful in the diagnosis of breast lesions, some lesions are very difficult to be diagnosed by FNA alone. We have to be careful in considering the conformity of the findings of image diagnoses with the cytological findings. Furthermore, when there is a lack of conformity between them, we should not to hesitate to perform CNB

  1. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

    Directory of Open Access Journals (Sweden)

    Baldini Enke

    2013-02-01

    Full Text Available Abstract Background Measurement of thyroglobulin (Tg protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN metastasis from well-differentiated thyroid cancer (TC. In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp, Tg mRNA (FNAB-Tgm and calcitonin (CT mRNA (FNAB-CTm in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC in 26 CLN, metastatic medullary TC (MTC in 3 CLN, metastatic anaplastic TC (ATC in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters.

  2. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology?

    Science.gov (United States)

    2013-01-01

    Background Measurement of thyroglobulin (Tg) protein in the washout of the needle used for fine needle aspiration biopsy cytology (FNAB-C) has been shown to increase the sensitivity of FNAB-C in identifying cervical lymph node (CLN) metastasis from well-differentiated thyroid cancer (TC). In this study, we evaluated whether routine measurement of Tg protein (FNAB-Tgp), Tg mRNA (FNAB-Tgm) and calcitonin (CT) mRNA (FNAB-CTm) in the FNAB washout of CLN increases the accuracy of FNAB-C in the diagnosis of suspicious metastatic CLN. Methods In this prospective study 35 CLN from 28 patients were examined. Histology showed metastatic papillary TC (PTC) in 26 CLN, metastatic medullary TC (MTC) in 3 CLN, metastatic anaplastic TC (ATC) in 3 CLN and 3 metastatic CLN from extra-thyroidal cancers. Results The overall accuracy of FNAB-C was 84.4%, reaching 95.7% when the analysis was restricted to PTC. Both FNAB-Tgp and FNAB-Tgm compared favorably with FNAB-C and shown diagnostic performances not statistically different from that of FNAB-C. However, FNAB-Tgp and FNAB-Tgm/FNAB-CTm were found useful in cases in which cytology results were inadequate or provided diagnosis inconsistent with patient's clinical parameters. Conclusions We demonstrated that FNAB-C, Tg/CT mRNA and Tg protein determination in the fine-needle washout showed similar accuracy in the diagnosis of metastatic CLN from TC. The results of this study suggest that samples for Tg protein and Tg/CT mRNA measurements from CLN suspicious for metastatic TC should be collected, but their measurements should be restricted to cases in which FNAB-C provides uninformative or inconsistent diagnosis with respect to patient's clinical parameters. PMID:23421519

  3. Determination of surface tension coefficient of liquids by diffraction of light on capillary waves

    International Nuclear Information System (INIS)

    Nikolić, D; Nešić, Lj

    2012-01-01

    This paper describes a simple technique for determining the coefficient of the surface tension of liquids, based on laser light diffraction on capillary waves. Capillary waves of given frequency are created by an exciter needle acting on the surface of liquid and represent a reflective diffraction grating, the constant of which (the wavelength of capillary waves) can be determined based on a known incidence angle of light (grazing angle). We obtain the coefficient of the surface tension of liquids by applying the dispersion relation for capillary waves and analyze the difficulties that arise when setting up and conducting the experiment in detail. (paper)

  4. Service quality of diagnostic fine needle aspiration cytology in a tertiary care hospital of lahore

    International Nuclear Information System (INIS)

    Rizvi, Z.; Usmani, R.A.; Zahra, T.; Rasool, H.; Rizvi, A.

    2017-01-01

    Quality of any service is the most important aspect for the manufacturer as well as the consumer. The primary objective of any nation's health system is to provide supreme quality health care services to its patients. The objective of this study was to assess the quality of diagnostic fine needle aspiration cytology service in a tertiary care hospital. As Patient's perspectives provide valuable information on quality of process, therefore, patient's perception in terms of satisfaction with the service was measured. Methods: In this cross sectional analytical study, 291 patients undergoing fine needle aspiration cytology in Mayo Hospital were selected by systematic sampling technique. Information regarding satisfaction of patients with four dimensions of service quality process, namely procedure, sterilization, conduct and competency of doctor was collected through interview on questionnaire. The questionnaire was developed on SERVQUAL model, a measurement tool, for quality assessment of services provided to patients. All items were assessed on 2- point likert scale (0=dissatisfied, 1=satisfied). Frequencies and percentages of satisfied and dissatisfied patients were recorded for each item and all items in each dimension were scored. If the percentage of sum of all item scores of a dimension was =60, the dimension was 'good quality'. Whereas <60% was 'poor quality' dimension. Data was analysed using epi-info-3.5.1. Fisher test was applied to check statistical significance. (p-value <0.05) Results: Out of the 4 dimensions of service quality process, Procedure (48.8%), Sterilization (51.5%) and practitioner conduct (50.9%) were perceived as 'poor' by the patients. Only practitioner competency (67.4%) was perceived as 'good'. Comparison of dimensions of service quality scoring with overall level of patient satisfaction revealed that all 4 dimensions were significantly related to patient dissatisfaction (p<.05) Conclusion: The study suggests that service quality of

  5. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    Science.gov (United States)

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  6. Numerical simulations of capillary barrier field tests

    International Nuclear Information System (INIS)

    Morris, C.E.; Stormont, J.C.

    1997-01-01

    Numerical simulations of two capillary barrier systems tested in the field were conducted to determine if an unsaturated flow model could accurately represent the observed results. The field data was collected from two 7-m long, 1.2-m thick capillary barriers built on a 10% grade that were being tested to investigate their ability to laterally divert water downslope. One system had a homogeneous fine layer, while the fine soil of the second barrier was layered to increase its ability to laterally divert infiltrating moisture. The barriers were subjected first to constant infiltration while minimizing evaporative losses and then were exposed to ambient conditions. The continuous infiltration period of the field tests for the two barrier systems was modelled to determine the ability of an existing code to accurately represent capillary barrier behavior embodied in these two designs. Differences between the field test and the model data were found, but in general the simulations appeared to adequately reproduce the response of the test systems. Accounting for moisture retention hysteresis in the layered system will potentially lead to more accurate modelling results and is likely to be important when developing reasonable predictions of capillary barrier behavior

  7. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  8. Fine-needle aspiration cytology of postirradiation sarcomas, including angiosarcoma, with immunocytochemical confirmation

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, J.F.; Lannin, D.L.; Larkin, E.W.; Feldman, P.; Frable, W.J. (East Carolina Univ. School of Medicine, Greenville, NC (USA))

    1989-01-01

    Postirradiation sarcomas are an unusual but well-recognized late effect of cancer therapy. In this article, a fine-needle aspiration (FNA) series of four cases is presented. There were three female patients and one male patient, with an age range of 28-55 yr (mean, 41). Two of the patients were irradiated for uterine cervical carcinoma while the other two received irradiation for malignant lymphoma. The time interval to the development of the postirradiation sarcoma ranged from 10 to greater than 20 yr. There were a postirradiation synovial sarcoma of the buttock region, malignant fibrous histiocytoma of the bone (femur), and rhabdomyosarcoma and angiosarcoma of the retroperitoneum. A spectrum of cytologic findings was encountered, reflecting the specific types of sarcomas. Immunocytochemical studies performed on the aspirated material from the angiosarcoma demonstrated the utility of immunoperoxidase stains for ULEX europaeus agglutinin-1 (UEA-1) and, to a lesser degree, factor VIII-related antigen antibody, confirming the vascular nature of this malignancy. The FNA findings from all four cases demonstrated cytologic features that allowed recognition of this unusual complication of irradiation treatment. This article confirms the utility of FNA cytology in following patients with previous malignancies and differentiating a postirradiation sarcoma from recurrent carcinoma.

  9. Fine-needle aspiration cytology of postirradiation sarcomas, including angiosarcoma, with immunocytochemical confirmation

    International Nuclear Information System (INIS)

    Silverman, J.F.; Lannin, D.L.; Larkin, E.W.; Feldman, P.; Frable, W.J.

    1989-01-01

    Postirradiation sarcomas are an unusual but well-recognized late effect of cancer therapy. In this article, a fine-needle aspiration (FNA) series of four cases is presented. There were three female patients and one male patient, with an age range of 28-55 yr (mean, 41). Two of the patients were irradiated for uterine cervical carcinoma while the other two received irradiation for malignant lymphoma. The time interval to the development of the postirradiation sarcoma ranged from 10 to greater than 20 yr. There were a postirradiation synovial sarcoma of the buttock region, malignant fibrous histiocytoma of the bone (femur), and rhabdomyosarcoma and angiosarcoma of the retroperitoneum. A spectrum of cytologic findings was encountered, reflecting the specific types of sarcomas. Immunocytochemical studies performed on the aspirated material from the angiosarcoma demonstrated the utility of immunoperoxidase stains for ULEX europaeus agglutinin-1 (UEA-1) and, to a lesser degree, factor VIII-related antigen antibody, confirming the vascular nature of this malignancy. The FNA findings from all four cases demonstrated cytologic features that allowed recognition of this unusual complication of irradiation treatment. This article confirms the utility of FNA cytology in following patients with previous malignancies and differentiating a postirradiation sarcoma from recurrent carcinoma

  10. Three-dimensional cytomorphology in fine needle aspiration biopsy of medullary thyroid carcinoma.

    Science.gov (United States)

    Chang, T C; Lai, S M; Wen, C Y; Hsiao, Y L; Huang, S H

    2001-01-01

    To elucidate three-dimensional (3-D) cytomorphology in fine needle aspiration biopsy (FNAB) of medullary thyroid carcinoma (MTC). ENAB was performed on tumors from five patients with MTC. The aspirate was stained and observed under a light microscope (LM). The aspirate was also fixed, dehydrated, critical point dried, spattered with gold ions and observed with a scanning electron microscope (SEM). For transmission electron microscopy (TEM), the specimen was fixed, dehydrated, embedded in an Epon mixture, cut with an ultramicrotome, mounted on copper grids, electron doubly stained with uranium acetate and lead citrate, and observed with TEM. Findings under SEM were correlated with those under LM and TEM. Under SEM, 3-D cytomorphology of MTC displayed a disorganized cellular arrangement with indistinct cell borders in three cases. The cell surface was uneven and had granular protrusions that corresponded to secretory granules observed under TEM. In one case with multiple endocrine neoplasia type IIB, there were abundant granules on the cell surface. In one case of sporadic MTC with multinucleated tumor giant cells and small cells, granular protrusions also were noted on the cell surface. Granular protrusion was a characteristic finding in FNAB of MTC tinder SEM and might be helpful in the differential diagnosis.

  11. Fine needle aspiration cytology of chondroblastoma: A report of two cases with brief review of pitfalls

    Directory of Open Access Journals (Sweden)

    Amita Krishnappa

    2016-01-01

    Full Text Available Chondroblastoma is a rare, giant cell-rich, benign neoplasm of bone. Since the past few decades fine needle aspiration cytology (FNAC has gained momentum in preoperative diagnosis of bone lesions. At cytology, other giant cell-rich tumors and tumorlike lesions such as aneurysmal bone cyst (ABC, giant cell tumor, and chondromyxoid fibroma fall under the differential diagnosis of chondroblastoma. Due to the difference in the treatment protocol and prognosis, preoperative diagnosis is mandatory. We describe the cytomorphology in two cases of chondroblastoma diagnosed at FNAC and confirmed by histopathology. At cytology, the presence of giant cells, chondroid matrix, mononuclear cells with nuclear indentation, and grooving along with glassy, vacuolated cytoplasm are characteristic of chondroblastoma. In addition to this, the presence of chicken wire calcification is a useful clue to the accurate diagnosis of chondroblastoma at FNAC.

  12. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics.

    Science.gov (United States)

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J; Sobrinho Simoes, Manuel

    2017-07-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF , NRAS , HRAS , KRAS , PAX8/PPARG , RET/PTC ) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation.

  13. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Pituitary carcinoma diagnosed on fine needle aspiration: Report of a case and review of pathogenesis

    Directory of Open Access Journals (Sweden)

    Yakoushina Tatiana

    2010-01-01

    Full Text Available Pituitary carcinoma (PC is a very rare entity (0.2% of all pituitary tumors, with only about 140 cases reported in English literature. There are no reliable histological, immunohistochemical or ultrastructural features distinguishing pituitary adenoma (PA from PC. By definition, a diagnosis of PC is made after a patient with PA develops non-contiguous central nervous system (CNS or systemic metastases. To date, only three cases of PC have been reportedly diagnosed on fine needle aspiration (FNA. Two of the reported cases were diagnosed on FNA of the cervical lymph nodes and one on FNA of the vertebral bone lesion. Herein, we present a case of PC, diagnosed on FNA of the liver lesion. In this case, we describe cytologic features of PC and compare them to histologic features of the tumor in the pituitary. Clinical behavior of tumor, pathogenesis of metastasis and immunochemical and prognostic markers will also be described.

  15. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  16. Fine needle aspiration cytology of radiation-induced changes in nonneoplastic breast lesions. Possible pitfalls in cytodiagnosis

    International Nuclear Information System (INIS)

    Peterse, J.L.; Thunnissen, F.B.; van Heerde, P.

    1989-01-01

    The range of radiation-induced changes in fine needle aspiration (FNA) smears of the breast is described. In 41 of more than 800 patients who underwent breast-conserving treatment, a palpable breast lesion developed, and FNA was performed. In six cases, a recurrent carcinoma was present. In the remaining cases, three patterns of nonneoplastic lesions could be discerned: epithelial atypia (14 cases), fat necrosis (10 cases) and poorly cellular smears without epithelial atypia or fat necrosis (13 cases). It is important to be familiar with the patterns of radiation-induced epithelial atypia, since such atypia may lead to a misdiagnosis of recurrent carcinoma. These atypical cells may show impressive anisocytosis and anisonucleosis; however, the nuclear/cytoplasmic ratio remains normal and an admixture of bipolar cells is present. Cell dissociation and necrotic cell debris, as often seen in breast cancer smears, were never encountered in FNA smears from radiated nonneoplastic breasts

  17. Fine-needle aspiration study of cystic papillary thyroid carcinoma: Rare cytological findings

    Directory of Open Access Journals (Sweden)

    Maral Mokhtari

    2016-01-01

    Full Text Available Background: Cystic papillary thyroid carcinoma (CPTC is a variant of papillary carcinoma that has many mimickers in cytological grounds. Aim: To study the cytomorphologic features of CPTC and compare them to those of other cystic thyroid lesions using fine-needle aspiration cytology (FNAC. We also aimed to identify the cytomorphologic features that distinguish CPTC from other cystic thyroid lesions. Materials and Methods: Seventy-three cases of CPTC were included in the study. The cytomorphologic features of these cases were analyzed. The FNA smears of other thyroid lesions with cystic changes (300 colloid goiters, 290 adenomatoid nodules, 11 follicular neoplasms, and 9 hurtle cell neoplasm were also studied. Results: The smears in CPTC revealed isolated follicular cells, small groups of cells with scalloped margins, cell swirls, small clusters with a cartwheel pattern, papillary clusters, intranuclear inclusions, nuclear grooves, sticky colloid, intracellular colloids, psammoma bodies, multinucleated giant cells, and foamy and hemosiderin laden macrophages. Small groups of cells with scalloped borders, cellular swirls, and small clusters with a cartwheel pattern were seen in CPTC, but not in other cystic lesions. Interestingly, mesothelial-like cells and hemophagocytic cells were seen in five and three cases of CPTC, respectively, but not in other cystic lesions. Conclusion: Mesothelial-like cells and hemophagocytic cells were observed in five and three cases of CPTC, respectively. Similar finding have not been previously reported in the literature.

  18. Fine-needle aspiration study of cystic papillary thyroid carcinoma: Rare cytological findings

    Science.gov (United States)

    Mokhtari, Maral; Kumar, Perikala Vijayananda; Hayati, Kamran

    2016-01-01

    Background: Cystic papillary thyroid carcinoma (CPTC) is a variant of papillary carcinoma that has many mimickers in cytological grounds. Aim: To study the cytomorphologic features of CPTC and compare them to those of other cystic thyroid lesions using fine-needle aspiration cytology (FNAC). We also aimed to identify the cytomorphologic features that distinguish CPTC from other cystic thyroid lesions. Materials and Methods: Seventy-three cases of CPTC were included in the study. The cytomorphologic features of these cases were analyzed. The FNA smears of other thyroid lesions with cystic changes (300 colloid goiters, 290 adenomatoid nodules, 11 follicular neoplasms, and 9 hurtle cell neoplasm) were also studied. Results: The smears in CPTC revealed isolated follicular cells, small groups of cells with scalloped margins, cell swirls, small clusters with a cartwheel pattern, papillary clusters, intranuclear inclusions, nuclear grooves, sticky colloid, intracellular colloids, psammoma bodies, multinucleated giant cells, and foamy and hemosiderin laden macrophages. Small groups of cells with scalloped borders, cellular swirls, and small clusters with a cartwheel pattern were seen in CPTC, but not in other cystic lesions. Interestingly, mesothelial-like cells and hemophagocytic cells were seen in five and three cases of CPTC, respectively, but not in other cystic lesions. Conclusion: Mesothelial-like cells and hemophagocytic cells were observed in five and three cases of CPTC, respectively. Similar finding have not been previously reported in the literature. PMID:27756982

  19. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Rho, Myung Ho; Kim, Ki Nam

    2009-01-01

    This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was

  20. Assay of free thyroxine and free triiodothyronine in fine-needle aspiration of thyroid nodules: a useful and low-cost assessment.

    Science.gov (United States)

    Barbaro, Daniele; Macchia, Enrico; Orsini, Paola; Piazza, Francesca; Lapi, Paola; Pasquini, Cristina

    2004-01-01

    To evaluate whether analysis of thyroid hormones in fine-needle aspiration (FNA) of thyroid nodules can provide information about the functional status and the nature of the nodules. We studied 4 groups of patients: group 1, 17 patients with autonomous hyperfunctioning thyroid nodules; group 2, 52 patients with cold nonfunctioning thyroid nodules; group 3, 12 patients with malignant thyroid nodules; and group 4 (control group), 10 patients with nonthyroid nodular lesions (enlarged parathyroid glands or lymph nodes). The assay of thyroid hormones was performed in FNA after the washing of needles and, with patient consent, also in normal thyroid parenchyma. The free thyroxine (FT(4)) and free triiodothyronine (FT(3)) values were remarkably high in group 1 (mean, 5.5 +/- 0.53 ng/dL and 27.6 +/- 3.1 pg/mL, respectively; Pnodules. These results show that assay of FT(4) and FT(3) in FNA can yield information about the functional status of thyroid nodules and, indirectly, about the nature of nodules. In this era of sophisticated new molecular markers in FNA cytology, this low-cost diagnostic method can be readily performed in every laboratory.

  1. Perineal nodular indurations ("accessory testicles") in cyclists. Fine needle aspiration cytologic and pathologic findings in two cases.

    Science.gov (United States)

    Vuong, P N; Camuzard, P; Schoonaert, M F

    1988-01-01

    The cytologic and histologic findings from two cases of perineal nodular indurations observed in two cyclists are reported. These lesions, also referred to as "accessory testicles" or "third testicle" or "ischial hygromas" of cyclists, consist of a localized aseptic area of necrosis with pseudocyst formation involving connective tissue in the superficial fascia of the perineum. These histologic findings, which were seen in the subsequent surgical specimens in these two cases, were reflected in the fine needle aspiration findings. The aspirates contained few cellular elements, mainly a few vacuolated histiocytes, against a background of fibrinous material. These indurations, which develop as a result of repeated, chronic microtrauma to the perineum impressed by the vibration of the saddle of the bicycle, constitute an authentic handicap for the professional cyclist and are a contraindication to cycling for amateur cyclists.

  2. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho [Ajou Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69{+-}2.0 and 1.11{+-}2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the

  3. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho

    1997-01-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69±2.0 and 1.11±2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the pulmonary

  4. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  5. Role of fine needle aspiration cytology in the preoperative investigation of branchial cysts.

    Science.gov (United States)

    Slater, Jacqueline; Serpell, Jonathan W; Woodruff, Stacey; Grodski, Simon

    2012-01-01

    Successful preoperative diagnosis of a branchial cyst requires a systematic approach. The aim of this study was to evaluate methods of investigation of a lateral neck swelling suspicious for a branchial cyst, and to highlight cases where a less benign cause for the swelling should be suspected and therefore management altered appropriately. A retrospective case study of 24 patients with presumed branchial cysts managed operatively was undertaken. Demographic, clinical, imaging, cytology and histopathological data were analysed to formulate an approach to the work-up of a lateral neck swelling suspected to be a branchial cyst. All 24 patients presented with a lateral neck mass thought to be a branchial cyst preoperatively underwent preoperative fine-needle aspiration cytology. The overall accuracy of cytology in predicting a benign branchial cyst histopathologically was 83.3% (20 out of 24). Successful preoperative diagnosis of a branchial cyst requires a combination of imaging and cytology. If there is concern that a lateral neck swelling is not a branchial cyst on clinical, imaging or cytological features, then a full preoperative work-up, including computed tomography scan of the neck and upper aero-digestive tract endoscopy should be performed, prior to an excisional biopsy. © 2011 The Authors. ANZ Journal of Surgery © 2011 Royal Australasian College of Surgeons.

  6. Fine needle aspiration cytology of granulomatous mastitis with special emphasis on microbiologic correlation.

    Science.gov (United States)

    Nemenqani, Dalal; Yaqoob, Nausheen; Hafiz, Momein

    2009-01-01

    To describe the cytomorphology of granulomatous mastitis (GM) and to evaluate the causative agents involved, proven on the basis of microbiologic culture results and polymerase chain reaction (PCR) studies. We retrospectively reviewed the inflammatory breast aspirates reported at King Abdul Aziz Specialist Hospital and Al Hada Armed Forces Hospital, Taif, Kingdom of Saudi Arabia, from January 2000 until March 2008. The pathology reports, clinical information, slides, microbiologic culture results and tuberculosis (TB)/PCR were reviewed. Cases of inflammatory carcinoma or duct ectasia were excluded. A total of 49 cases of inflammatory breast aspirates were identified, of which 15 cases were GM. The microbiologic cultures of all 15 cases were available. Six of 15 cases had positive culture for Brucella melitenses, and 2 cases were positive for TB, which was further confirmed by TB/PCR. The fungal cultures were negative in all the cases. Seven of 15 cases were classified as idiopathic GM. Fine needle aspiration cytology was found to be a useful tool in the early diagnosis of GM and its classification if performed by a pathologist as the material can be submitted for culture. The definitive diagnosis can be established by a combination of the cytomorphologic features and microbiologic studies.

  7. Current status of fine needle aspiration for thyroid nodules.

    Science.gov (United States)

    Ogilvie, Jennifer B; Piatigorsky, Eli J; Clark, Orlo H

    2006-01-01

    When not to perform fine needle aspiration of a thyroid nodule In summary, FNA of thyroid nodules has become one of the most useful, safe, and accurate tools in the diagnosis of thyroid pathology. Thyroid nodules that should be considered for FNA include any firm, palpable, solitary nodule or nodule associated with worrisome clinical features (rapid growth, attachment to adjacent tissues, new hoarseness, or palpable lymphadenopathy). FNA should also be performed on nodules with suspicious ultrasonographic features (microcalcifications, rounded shape, predominantly solid composition); dominant or atypical nodules in multinodular goiter; complex or recurrent cystic nodules; or any nodule associated with palpable or ultrasonographically abnormal cervical lymph nodes. Finally, FNA should be performed on any abnormal-appearing or palpable cervical lymph nodes. The management of thyroid nodules based on FNA findings is summarized in Table 2. It can be argued that in certain circumstances the results of thyroid FNA do not change the surgical management of a thyroid nodule, and thus preoperative FNA may be unnecessary. These cases include solitary nodules in patients who have a strong family history of thyroid cancer, multiple endocrine neoplasia type II, or radiation to the head and neck. These patients when they have thyroid nodules have at least a 40% risk for thyroid cancer and frequent multifocal or bilateral disease and should undergo total thyroidectomy with or without central neck lymph node dissection. Patients who have multinodular goiter and compressive symptoms, patients who have Graves disease and a thyroid nodule, or patients who have large (greater than 4 cm) or symptomatic unilateral thyroid nodules could also be considered for total thyroidectomy or lobectomy as indicated without preoperative FNA. Finally, patients who have a solitary hyperfunctioning nodule on radioiodine scan and a suppressed TSH have an extremely low incidence of malignancy and may be

  8. Diagnosis of sclerosing hemangioma of lung: Don′t rely on fine-needle aspiration cytology diagnosis alone

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2013-01-01

    Full Text Available Sclerosing hemangioma is a rare variety of benign pulmonary neoplasm. It usually presents as asymptomatic, solitary, peripheral, circumscribed lesions in middle-aged women. Here, we describe a 46-year-old woman presenting to us for evaluation of right parahilar lung mass. Previous chest radiography done 10 years back showed a lung mass of almost similar size. Computed Tomography (CT-guided fine-needle aspiration cytology (FNAC was suggestive of adenocarcinoma of lung. A well-circumscribed, capsulated, ovoid mass measuring 5.6 cm × 4 cm × 3 cm, adjacent to the transverse fissure of the right lung was excised by lateral thoracotomy. Histopathological examination along with immunohistochemistry was suggestive of sclerosing hemangioma of lung. A pathologist must consider the clinicoradiological features before coming to a final diagnosis of lung malignancy from FNAC. Whenever there is any confusion regarding lung mass, thoracotomy must be done for arriving at an exact diagnosis from histopathology.

  9. A STUDY OF A SPECTRUM OF LESIONS IN FINE NEEDLE ASPIRATION SMEARS OF CERVICAL LYMPH NODE AMONG WORKERS IN A TEXTILE INDUSTRY AREA

    Directory of Open Access Journals (Sweden)

    Veenaa Natchimuthu

    2017-01-01

    Full Text Available BACKGROUND Textile industry workers face so many health-related challenges compared to the general population. Lymphadenopathy is one of the most common presenting symptoms of these people. This study is done in inhabitants of Tiruppur, a major textile industry area in the state of Tamil Nadu, India, where people work in garment factories for low wages. The aim of the study is to- 1. Evaluate the usefulness of Fine Needle Aspiration Cytology (FNAC as a diagnostic tool in cases of cervical lymphadenopathy. 2. Analyse the various cytomorphological presentations of tuberculous lymphadenopathy. MATERIALS AND METHODS In this study, a spectrum of lesions was diagnosed by fine needle aspiration of lymph nodes of 56 patients presenting with cervical lymphadenopathy. The diseases were categorised into suppurative lymphadenitis, granulomatous lymphadenitis, metastatic tumour deposits and lymphoproliferative disorder. Various morphological presentations of tuberculous lymphadenitis were also analysed. RESULTS From this study, it is observed that the most common diagnosis of cervical lymphadenopathy is reactive lymphadenitis (34%, followed by granulomatous lymphadenitis (30%. Also, among the tuberculosis cases, it is found that majority of cases had only granulomas (45% followed by caseous necrosis with granulomas (28%. CONCLUSION Knowing the usefulness of FNAC, it is concluded that it is a valuable, noninvasive, reliable and cost-effective technique in such a high-risk population. It also helps the clinician to start treatment based on FNAC findings and do the necessary at the earliest.

  10. Solitary thyroid metastasis from colon cancer: fine-needle aspiration cytology and molecular biology approach.

    Science.gov (United States)

    Onorati, M; Uboldi, P; Bianchi, C L; Nicola, M; Corradini, G M; Veronese, S; Fascì, A I; Di Nuovo, F

    2015-01-01

    Thyroid gland is one of the most vascularized organs of the body, nevertheless clinical and surgical series report an incidence of secondary malignancies in this gland of only 3%. Colorectal carcinoma metastatic to the thyroid gland is not as uncommon as previously believed, infact the number of cases seems to be increased in recent years due to the more frequent use of fine-needle aspiration cytology (FNAC) guided by ultrasonography. Although kidney, breast and lung metastases to the thyroid are frequent, metastasis from colon cancer is clinically rare with 52 cases reported in the literature in the last 5 decades and three cases described as solitary thyroid metastasis from the colon cancer without any other visceral metastases. To the best of our knowledge, we report the fourth case of solitary, asymptomatic thyroid metastasis from colon cancer without involvement of other organs. We discuss the importance of FNAC to detect metastatazing process as a compulsory step of the diagnostic and therapeutic management algorithm, combined with a molecular biology approach. A review of the last 5 decades literature, to update the number of cases described to date, is also included.

  11. A Cross Section Study to Correlate Fine Needle Aspiration Cytology ...

    African Journals Online (AJOL)

    ADMIN

    Background: Needle Aspiration Cytology (FNAC) is cheap, simple, quick, minimally invasive procedure that is widely used for preoperative diagnosis of Parotid tumours. Methods: Twenty five patients were prospectively studied over a two-year period at four major hospitals in Zambia. FNAC was done using a 10cc syringe ...

  12. Perineal nodular induration ("Biker's nodule"): report of two cases with fine-needle aspiration cytology and immunohistochemical study.

    Science.gov (United States)

    Khedaoui, Radia; Martín-Fragueiro, Luz M; Tardío, Juan C

    2014-02-01

    Perineal nodular induration (PNI) is a fibroblastic pseudotumor that presents almost exclusively in male cyclists. It develops in the soft tissues of the perineum immediately posterior to the scrotum, as a bilateral or single, central or lateralized mass. Although well known to sport medicine specialists, it is a scarcely documented entity in the pathology literature. We present 2 cases of PNI with fine-needle aspiration cytology and immunohistochemistry. They consisted of a paucicellular fibroblastic proliferation containing CD34-reactive spindle and epithelioid cells, small foci of fibrinoid degeneration, numerous blood vessels, and entrapped groups of mature fat cells. Our cases show that the histopathological features of PNI are more varied than those previously described and its immunohistochemical profile is wider. A central cystic focus and a zonal pattern are not consistent features of this entity. The lesional cells can express CD34, a hitherto unreported immunohistochemical finding.

  13. Harmonic Contrast-Enhanced Endoscopic Ultrasonography for the Guidance of Fine-Needle Aspiration in Solid Pancreatic Masses

    DEFF Research Database (Denmark)

    Seicean, A; Badea, R; Moldovan-Pop, A

    2015-01-01

    Purpose: The global accuracy of fine-needle aspiration guided by endoscopic ultrasound (EUS-FNA) for pancreatic adenocarcinoma is about 85 %. The use of contrast agents during EUS to highlight vessels and the necrotic parts of pancreatic masses may improve biopsy guidance. Our aim was to assess...... whether the guidance of FNA by harmonic contrast-enhanced endoscopic ultrasound (CH-EUS) would increase diagnostic accuracy relative to conventional EUS-FNA in the same pancreatic masses. Patients and Methods: In a prospective study, EUS-FNA was performed in patients with pancreatic masses on CT scan......, followed by harmonic CH-EUS using SonoVue. A second cluster of CH-EUS-FNA was performed on contrast-enhanced images. The final diagnosis was based on the results of EUS-FNA and surgery, or the findings after 12 months' follow-up. Results: The final diagnosis was adenocarcinoma (n = 35), chronic...

  14. Papillary thyroid carcinoma: How much should the surgeon read from Fine needle aspiration cytology reports?

    Directory of Open Access Journals (Sweden)

    Das Dilip

    2010-10-01

    Full Text Available Objective: During routine fine needle aspiration cytodiagnosis of papillary thyroid carcinoma (PTC, a number of cases are diagnosed as suspicious; or it is suggested that PTC or a neoplasm be ruled out by histopathology. Since these diagnostic labels are likely to put the clinicians in a difficult situation while planning the management, this study aims to find out how much the surgeon should read from these reports. Materials and Methods: The patients were divided into two groups. Group A included 38 cases diagnosed as PTC or suspicious of PTC. Group B included 40 cases in which it was suggested that PTC/a neoplasm to be ruled out and non-neoplastic lesions with one or more cytologic features of PTC. The two groups were compared with clinical, imaging and cytomorphologic features. Results: A significant difference was observed with respect to age between Group A and Group B (P<0.001. The frequency of the following five cytologic features was significantly higher in Group A: papillary formation (P<0.001, psammoma bodies (P=0.054, fine nuclear chromatin (P=0.010, frequent nuclear grooves (P<0.001 and intra-nuclear cytoplasmic inclusion (P<0.001. Three or more of the five cytologic features were also reported in significantly higher number of Group A cases (P<0.001. Majority (81.8% of the cases with subsequent histology in Group A were confirmed as PTC as opposed to 7.7% in Group B (P<0.001. Conclusions: Thus, cases with definitive cytodiagnosis of PTC and suggestive of PTC (Group A should be taken much more seriously by the surgeons as compared to Group B cases.

  15. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses

    DEFF Research Database (Denmark)

    Vilmann, Peter; S?ftoiu, Adrian; Hollerbach, Stephan

    2013-01-01

    Few randomized studies have assessed the clinical performance of 25-gauge (25G) needles compared with 22-gauge (22G) needles during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) biopsy of intra-abdominal lesions. We aimed to compare the diagnostic yield, as well as performance...

  16. Evaluation of a mammographic stereotactic device for localization, fine-needle aspiration cytologic studies, and core biopsy of suspicious lesions

    International Nuclear Information System (INIS)

    Fajardo, L.J.; Davey, G.A.

    1988-01-01

    Mammography-guided interventional breast procedures, such as preoperative localization, fine-needle aspiration cytology (FNAC), and core biopsy of suspicious lesions, require accurate three-dimensional localization. The authors have evaluated a prototype stereotactic mammography device for localizing abnormalities with both phantom and clinical studies. Twenty-six localizations on a phantom were within 0.5 mm +- 0.93 (standard deviation) from the lesions; accuracy in clinical procedures was within 0.6 mm +- 0.8. Procedures are performed an average of 8 minutes faster with this device. They are prospectively evaluating mammography-guided FNAC and core biopsy of suspicious lesions in 100 patients. Results of FNAC performed without the stereotactic device agreed with results of open surgical biopsy in six of eight patients; results of core biopsy agreed in seven of eight

  17. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    Science.gov (United States)

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  18. Capillary density and capillary-to-fibre ratio in vastus lateralis muscle of untrained and trained men.

    Science.gov (United States)

    Zoladz, J A; Semik, D; Zawadowska, B; Majerczak, J; Karasinski, J; Kolodziejski, L; Duda, K; Kilarski, W M

    2005-01-01

    Muscle fibre profile area (Af), volume density (Vv), capillary-to-fibre ratio (CF) and number of capillaries per fibre square millimetre (CD) were determined from needle biopsies of vastus lateralis of twenty-four male volunteers (mean +/- SD: age 25.4+/-5.8 years, height 178.6+/-5.5 cm, body mass 72.1+/-7.7 kg) of different training background. Seven subjects were untrained students (group A), nine were national and sub-national level endurance athletes (group B) with the background of 7.8+/-2.9 years of specialised training, and eight subjects were sprint-power athletes (group C) with 12.8+/-8.7 years of specialised training. Muscle biopsies of vastus lateralis were analysed histochemically for mATPase. Capillaries were visualized and counted using CD31 antibodies against endothelial cells. There were significant differences in the Vv of type I and type II muscle fibres in both trained groups, B (51.8%; 25.6%) and C (50.5%; 26.4%). However, in untrained group A that was treated as a reference group, the difference between Vv of type I and type II fibres was less prominent, nevertheless statistically significant (42.1%; 35.1%). There was also a significant difference in CF: 1.9 in group A and 2.1 in groups B and C. The number of capillaries per mm2 (CD) was 245 (group A), 308 (group B) and 325 (group C). Significant differences (Pski-jumping, volleyball, soccer and modern dance.

  19. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  20. Endoscopic ultrasound with fine needle aspiration and biopsy in lung cancer and isolated mediastinal lymphadenopathy.

    LENUS (Irish Health Repository)

    Nadarajan, P

    2010-03-01

    Endoscopic ultrasound with fine-needle aspiration and biopsy (EUS-FNAB) is well established in diagnosing and staging lung cancer in patients with mediastinal adenopathy. EUS-FNAB is highly sensitive, less invasive and has lower complication rates when compared to surgical staging of mediastinal nodes. In this study we describe our experience of EUS-FNAB in lung cancer and other causes of mediastinal lymphadenopathy. EUS-FNAB was performed for assessment of PET positive mediastinal lymph nodes between January 2007 and March 2009 in AMNCH. The endpoints of our study were sensitivity and specificity of EUS-FNAB, morbidity and length of hospital stay. Thirty four patients underwent EUS-FNAB during the study period for both diagnosis and staging. Thirty patients had positive lymph node invasion and 4 had no evidence of malignant invasion. In these 4 patients negative cytology was confirmed on mediastinoscopy giving EUS-FNAB a sensitivity and specificity of 100%. EUS-FNAB upstaged the disease in 12 patients. EUS-FNAB is a reliable tool for mediastinal staging in lung cancer, significantly reducing the need for surgical staging procedures in patients with suspected mediastinal involvement.

  1. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  2. Viscous properties of ferrofluids containing both micrometer-size magnetic particles and fine needle-like particles

    Energy Technology Data Exchange (ETDEWEB)

    Ido, Yasushi, E-mail: ido.yasushi@nitech.ac.jp [Department of Electric and Mechanical Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya (Japan); Nishida, Hitoshi [Department of Electrical and Control Systems Engineering, National Institute of Technology, Toyama College, 13 Hongo-cho, Toyama (Japan); Iwamoto, Yuhiro [Department of Electric and Mechanical Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya (Japan); Yokoyama, Hiroki [KYB Corporation, 2-4-1 Hamamatsu-cho, Minato-ku, Tokyo (Japan)

    2017-06-01

    Ferrofluids containing both micrometer-size spherical magnetic particles and nanometer-size needle-like nonmagnetic hematite particles were newly produced. Average length of long axis of the needle-like nonmagnetic particles was 194 nm and the aspect ratio was 8.3. Shear stress and viscosity were measured using the rheometer with the additional equipment for viscosity measurements in the presence of magnetic field. When the total volume fraction of particles in the fluid is constant (0.30), there is the specific mixing ratio of the particles to increase viscosity of the fluid drastically in the absence of magnetic field due to the percolation phenomenon. The fluid of the specific mixing ratio shows solid-like behavior even in the absence of magnetic field. Mixing the needle-like nonmagnetic particles causes strong yield stress and strong viscous force in the presence of magnetic field. - Highlights: • Viscous properties of new magnetic functional fluids were studied experimentally. • The new fluids contain spherical magnetic particles and needle-like particles. • Percolation occurs in the fluid of specific mixing ratio of particles without field. • The fluid of the specific mixing ratio behaves like solid without field. • Mixing needle-like particles causes strong yield stress of the fluid in the field.

  3. Evaluation of capillary pore size characteristics in high-strength concrete at early ages

    International Nuclear Information System (INIS)

    Igarashi, Shin-ichi; Watanabe, Akio; Kawamura, Mitsunori

    2005-01-01

    The quantitative scanning electron microscope-backscattered electron (SEM-BSE) image analysis was used to evaluate capillary porosity and pore size distributions in high-strength concretes at early ages. The Powers model for the hydration of cement was applied to the interpretation of the results of image analysis. The image analysis revealed that pore size distributions in concretes with an extremely low water/binder ratio of 0.25 at early ages were discontinuous in the range of finer capillary pores. However, silica-fume-containing concretes with a water/binder ratio of 0.25 had larger amounts of fine pores than did concretes without silica fume. The presence of larger amounts of fine capillary pores in the concretes with silica fume may be responsible for greater autogenous shrinkage in the silica-fume-containing concretes at early ages

  4. Detection of PAX8/PPARG and RET/PTC Rearrangements Is Feasible in Routine Air-Dried Fine Needle Aspiration Smears

    DEFF Research Database (Denmark)

    Ferraz, Carolina; Rehfeld, Christian; Krogdahl, Annelise

    2012-01-01

    Background: The diagnostic limitations of fine needle aspiration (FNA), like the indeterminate category, can be partially overcome by molecular analysis. As PAX8/PPARG and RET/PTC rearrangements have been detected in follicular thyroid carcinomas (FTCs) and papillary thyroid carcinomas (PTCs......), their detection in FNA smears could improve the FNA diagnosis. To date, these rearrangements have never been analyzed in routine air-dried FNA smears, but only in frozen tissue, formalin-fixed paraffin-embedded (FFPE) tissue, and in fresh FNA material. Fixed routine air-dried FNA samples have hitherto been judged...... as generally not suitable for testing these rearrangements in a clinical setting. Therefore, the objective of the present study was to investigate the feasibility of extracting RNA from routine air-dried FNA smears for the detection of these rearrangements with real-time polymerase chain reaction (RT...

  5. Service Quality Of Diagnostic Fine Needle Aspiration Cytology In A Tertiary Care Hospital Of Lahore (Process Measure As Patient's Perspective).

    Science.gov (United States)

    Rizvi, Zainab; Usmani, Rabia Arshed; Rizvi, Amna; Wazir, Salim; Zahra, Taskeen; Rasool, Hafza

    2017-01-01

    Quality of any service is the most important aspect for the manufacturer as well as the consumer. The primary objective of any nation's health system is to provide supreme quality health care services to its patients. The objective of this study was to assess the quality of diagnostic fine needle aspiration cytology service in a tertiary care hospital. As Patient's perspectives provide valuable information on quality of process, therefore, patient's perception in terms of satisfaction with the service was measured. In this cross sectional analytical study, 291 patients undergoing fine needle aspiration cytology in Mayo Hospital were selected by systematic sampling technique. Information regarding satisfaction of patients with four dimensions of service quality process, namely "procedure, sterilization, conduct and competency of doctor" was collected through interview on questionnaire. The questionnaire was developed on SERVQUAL model, a measurement tool, for quality assessment of services provided to patients. All items were assessed on 2- point likert scale (0=dissatisfied, 1=satisfied). Frequencies and percentages of satisfied and dissatisfied patients were recorded for each item and all items in each dimension were scored. If the percentage of sum of all item scores of a dimension was ≥60, the dimension was 'good quality'. Whereas quality' dimension. Data was analysed using epi-info-3.5.1. Fisher test was applied to check statistical significance. (p-value service quality process, Procedure (48.8%), Sterilization (51.5%) and practitioner conduct (50.9%) were perceived as 'poor' by the patients. Only practitioner competency (67.4%) was perceived as 'good'. Comparison of dimensions of service quality scoring with overall level of patient satisfaction revealed that all 4 dimensions were significantly related to patient dissatisfaction (pservice quality of therapeutic and diagnostic procedures in public hospitals should be routinely monitored from the patients

  6. Relocation of carbon from decomposition of {sup 14}C-labelled needle and fine root litter in peat soil

    Energy Technology Data Exchange (ETDEWEB)

    Domish, T; Laine, J; Laiho, R [Helsinki Univ. (Finland). Dept. of Forest Ecology; Finer, L [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Karsisto, M [Finnish Forest Research Inst. (Finland). Dept. of Forest Ecology

    1997-12-31

    Drainage of peatlands promotes a shift of biomass and production from the ground vegetation to the trees. Thus, the above-ground (e.g. needles) and below-ground (roots) litter production of trees increases. Fine roots in particular are an important factor in the carbon and nutrient cycle in forest ecosystems. A major part of the annual net primary production of trees may be allocated below ground, the relative proportion being smaller on fertile sites than on less fertile ones. For modelling the carbon balance of drained peatlands, it is important to know the fate of carbon from newly introduced and decomposing litter. Newly added and fertilised tree litter material may be decomposed at a rate different than litter from the ground vegetation. The objectives of this study are to study the pathways of decomposing litter carbon in peat soil and to evaluate the use of the litterbag method in a controlled environment. (9 refs.)

  7. Relocation of carbon from decomposition of {sup 14}C-labelled needle and fine root litter in peat soil

    Energy Technology Data Exchange (ETDEWEB)

    Domish, T.; Laine, J.; Laiho, R. [Helsinki Univ. (Finland). Dept. of Forest Ecology; Finer, L. [Finnish Forest Research Inst. (Finland). Joensuu Research Station; Karsisto, M. [Finnish Forest Research Inst. (Finland). Dept. of Forest Ecology

    1996-12-31

    Drainage of peatlands promotes a shift of biomass and production from the ground vegetation to the trees. Thus, the above-ground (e.g. needles) and below-ground (roots) litter production of trees increases. Fine roots in particular are an important factor in the carbon and nutrient cycle in forest ecosystems. A major part of the annual net primary production of trees may be allocated below ground, the relative proportion being smaller on fertile sites than on less fertile ones. For modelling the carbon balance of drained peatlands, it is important to know the fate of carbon from newly introduced and decomposing litter. Newly added and fertilised tree litter material may be decomposed at a rate different than litter from the ground vegetation. The objectives of this study are to study the pathways of decomposing litter carbon in peat soil and to evaluate the use of the litterbag method in a controlled environment. (9 refs.)

  8. Diagnostic value of BRAFV600E-mutation analysis in fine-needle aspiration of thyroid nodules: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Su X

    2016-04-01

    Full Text Available Xingyun Su,1 Xiaoxia Jiang,1 Xin Xu,1 Weibin Wang,1 Xiaodong Teng,2 Anwen Shao,3 Lisong Teng1 1Department of Surgical Oncology, 2Department of Pathology, First Affiliated Hospital, 3Department of Neurosurgery, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People’s Republic of China Abstract: Fine-needle aspiration (FNA is a reliable method for preoperative diagnosis of thyroid nodules; however, about 10%–40% nodules are classified as indeterminate. The BRAFV600E mutation is the most promising marker for thyroid FNA. This meta-analysis was conducted to investigate the diagnostic value of BRAFV600E analysis in thyroid FNA, especially the indeterminate cases. Systematic searches were performed in PubMed, Web of Science, Scopus, Ovid, Elsevier, and the Cochrane Library databases for relevant studies prior to June 2015, and a total of 88 studies were ultimately included in this meta-analysis. Compared with FNA cytology, the synergism of BRAFV600E testing increased the diagnostic sensitivity from 81.4% to 87.4% and decreased the false-negative rate from 8% to 5.2%. In the indeterminate group, the mutation rate of BRAFV600E was 23% and varied in different subcategories (43.2% in suspicious for malignant cells [SMC], 13.77% in atypia of undetermined significance/follicular lesion of undetermined significance [AUS/FLUS], and 4.43% in follicular neoplasm/suspicious for follicular neoplasm [FN/SFN]. The sensitivity of BRAFV600E analysis was higher in SMC than that in AUS/FLUS and FN/SFN cases (59.4% vs 40.1% vs 19.5% respectively, while specificity was opposite (86.1% vs 99.5% vs 99.7% respectively. The areas under the summary receiver-operating characteristic curve also confirmed the diagnostic value of BRAFV600E testing in SMC and AUS/FLUS rather than FN/SFN cases. Therefore, BRAFV600E analysis can improve the diagnostic accuracy of thyroid FNA, especially indeterminate cases classified as SMC, and select malignancy

  9. Diagnostic accuracy of fine needle biopsy in the management of thyroid pathology in the Hospital Mexico in 2011-2012

    International Nuclear Information System (INIS)

    Elizondo Herrera, Luis Guillermo

    2013-01-01

    The nodule has been a very common thyroid pathology; through palpation is located in a 5% of the population and through ultrasound this figure has increased by almost 50%. The thyroid nodule has been the shape of presentation of thyroid cancer; the majority of times asymptomatic and most recently has shown without relation to the size of the nodule, 5 to 15% of thyroid nodules are malignant. This requires to classify clinically, to decide which patient requires surgical management. In Costa Rica, and especially in the CCSS (Caja Costarricense de Seguro Social); It has had two tools for perform differentiation: ultrasound and FNA (fine needle aspiration biopsy). The diagnostic accuracy of these tests has allowed minimize thyroid surgeries in patients with benign nodules and sift patients with thyroid nodules into search for cancer of thyroid. Previous to routine use of FNA was resected only 14% of malignant nodules, now are resected more than 50%. The diagnostic accuracy of these tests is related to technical aspects and also with the structural and histological features of the lesions valued. The limitations and scope described have allowed to optimize the utilization of direct and indirect costs related to the management of patients with thyroid nodules and decrease morbidity in the management of thyroid pathology. The sensitivity and specificity of fine needle biopsy varies, as is noted in various publications, according to the reference center, has been quite reliable between 0.3 and 3 cm and is highly specific in the case of papillary carcinoma. The diagnostic accuracy of the test has never been studied in the Hospital Mexico. Of the total population for the period 2011-2012, it is documented that the FNA is a study of high specificity (95,5%), with value predictive negative and positive appropriate (>75%) and with an intermediate sensitivity (55,6%). The analysis of ultrasound and FNA as parallel testing has allowed greater sensitivity. The use of ultrasound

  10. Comparison of specimen adequacy in fine-needle aspiration biopsies performed by surgeons and pathologists

    International Nuclear Information System (INIS)

    Al-Marzooq, Yusef M.; Chopra, Rajan; Al-Bahrani, Ahmed T.; Younis, Mohammad; Al-Mulhim, Abdulrahman S.; Al-Mommatten, Mohammed I.

    2004-01-01

    Fine-needle aspiration biopsy (FNAB) may yield different results depending on its operator. We compared the proportions of unsatisfactory aspirates obtained by pathologists vs. surgeons. In a retrospective review, all FNAB reports and slides performed between March 2002 and February 2003 were grouped by organ/site and according to whether they were done by pathologist or a surgeon. The proportions of unsatisfactory aspirates for pathologists and surgeons were compared. Of 692 FNAB's, 390 were performed by pathologists at the FNAC clinic and the remainder by surgeons. Overall, 15.5% of aspirates obtained were unsatisfactory (n=107). Of aspirates obtained by surgeons, 29.5% were unsatisfactory, compared to 4.6% of those obtained by pathologists (P<0.001). Pathologists had significantly lower proportions of unsatisfactory aspirates in all sites. A 33% reduction in the number of lymph node excisional biopsies has been reported subsequent to establishment of the FNAC clinic. The advantages of a pathologist performing FNAB are that a rapid evaluation can be rendered regarding specimen adequacy and the need for repeating the procedure. In addition, pathologists can direct the distribution of aspirated material for other tests such as culture study, flow cytometry and electron microscopy, as indicated by preliminary evaluation of the smears. These factors significantly lower the proportions of unsatisfactory specimens and improve the diagnstic accuracy of FNAB technique. (author)

  11. Diagnosis of Follicular Lesions of Undetermined Significance in Fine-Needle Aspirations of Thyroid Nodules

    Directory of Open Access Journals (Sweden)

    J. Ratour

    2013-01-01

    Full Text Available Aim. We aimed to analyze the diagnostic criteria proposed by the Bethesda System for Reporting Thyroid Cytopathology for follicular lesions of undetermined significance (FLUS, the risk of cancer and diagnostic improvement with use of immunocytochemistry. Methods. For each FLUS diagnosis, we analyzed the cytological criteria (9 Bethesda criteria, secondary fine-needle aspiration (FNA results, surgical procedures, contribution of immunocytochemistry with the antibodies cytokeratin 19 (CK19 and monoclonal anti-human mesothelial cell (HBME1. Results. Among patients with 2,210 thyroid FNAs, 244 lesions (337 nodules were classified as FLUS (11% of all thyroid FNAs. The 3 criteria most often applied were cytological atypia suggesting papillary carcinoma (36%, microfollicular architecture but sparse cellularity (23.1%, cytological atypia (21.5%. With secondary FNA, 48.8% of nodules were reclassified as benign. For about half of all cases (41.4% for the first FNA, 57.6% for the second FNA, immunocytochemistry helped establishing a diagnosis favoring malignant or benign. No benign immunocytochemistry results were associated with a malignant lesion. In all, 22.5% of the 39 removed nodules were malignant. Conclusion. The FLUS category is supported by well-described criteria. The risk of malignancy in our series was 22.5%. Because we had no false-negative immunocytochemistry results, immunocytochemistry could be helpful in FLUS management.

  12. Correlation of fine needle aspiration cytology with histopathology findings in cases of thyroid lesions in Bir Hospital

    Directory of Open Access Journals (Sweden)

    PB Thapa

    2014-01-01

    Full Text Available Aims: To correlate the findings of fine needle aspiration cytology (FNAC with the histopathology( HPE of the excised nodule or specimen and to assess the accuracy and efficacy of FNAC in the diagnosis of the thyroid nodules. Materials and methods: This is a prospective study conducted at the Department of Ear Nose Throat (ENT & Head & NecK Surgery( HNS, National Academy of Medical Sciences, Bir Hospital, Kathmandu from 2nd January 2009 to 29th December 2011. One hundred patients with thyroid nodule were included in the study. Results: Out of 100 patients 77 were females and 23 males. The age ranged from 11-60 years. Statistical analysis of results for Benign Thyroid lesion showed 98.6% sensitivity, 75 % specificity. Likewise, results for Malignant thyroid lesions showed 75 % sensitivity, 98.6 % specificity . Conclusion: FNAC has high accuracy in the diagnostic evaluation of thyroid lesions. Journal of College of Medical Sciences-Nepal, 2013, Vol-9, No-1, 23-29 DOI: http://dx.doi.org/10.3126/jcmsn.v9i1.9670

  13. Are needle-free injections a useful alternative for growth hormone therapy in children? Safety and pharmacokinetics of growth hormone delivered by a new needle-free injection device compared to a fine gauge needle.

    NARCIS (Netherlands)

    Dorr, H.G.; Zabransky, S.; Keller, E.; Otten, B.J.; Partsch, C.J.; Nyman, L.; Gillespie, B.K.; Lester, N.R.; Wilson, A.M.; Hyren, C.; Kuijck, M.A. van; Schuld, P.; Schoenfeld, S.L.

    2003-01-01

    The clinical safety, use and pharmacokinetics of a new needle-free device for delivery of growth hormone (GH) were compared with those of conventional needle injection devices. In an open-label, randomized, 4-period crossover study, 18 healthy adults received single subcutaneous injections of

  14. Fine needle aspiration biopsy diagnosis of dedifferentiated liposarcoma: Cytomorphology and MDM2 amplification by FISH

    Directory of Open Access Journals (Sweden)

    Al-Maghraby Hatem

    2010-01-01

    Full Text Available Lipomatous mesenchymal tumors constitute the most common type of soft tissue tumors. Well-differentiated liposarcoma (WDLS can undergo dedifferentiation to a nonlipogenic sarcoma of variable histologic grade. In the recent literature, amplification of the murine double minute 2 (MDM2 oncogene, which has a role in cell cycle control, has been successful in distinguishing WDLS from benign lesions. We present a case of dedifferentiated liposarcoma diagnosed by fine-needle aspiration (FNA, using cytomorphology and ancillary studies (immunocytochemistry and fluorescent in-situ hybridization. An 85-year old female presented to our institution with a firm soft tissue mass of the right buttock. The FNA showed atypical spindle cells, osteoclast-like giant cells and extracellular dense matrix material. The cell block showed cellular groups of highly atypical spindle cells with osteoid and adipose tissue. Fluorescence in situ hybridization (FISH studies performed on the cell block demonstrated amplification of the MDM2 gene. In addition, the findings were morphologically compatible with the previously resected retroperitoneal dedifferentiated liposarcoma with areas of osteosarcoma. This rare case illustrates the usefulness of FNA and ancillary studies in the diagnosis and subclassification of soft tissue tumors. To the best of our knowledge, this is the first report of MDM2 FISH positivity in a liposarcoma diagnosed by FNA.

  15. Solitary metastatic cancer to the thyroid: a report of five cases with fine-needle aspiration cytology

    Directory of Open Access Journals (Sweden)

    Batoroev Yuri

    2007-01-01

    Full Text Available Abstract Three men and 2 women with ages ranging from 37 to 70 years, clinically and histologically confirmed solitary, palpable metastatic cancers to the thyroid (SMCT and preoperative cytologic investigation of their thyroid lesions by fine-needle aspiration (FNA, were reviewed. Four patients were known to have a solid cancer treated by radical surgery 1 to 4 years prior [1 bronchogenic squamous cell carcinoma, 1 parotid adenoid cystic carcinoma, 1 renal cell carcinoma (RCC and 1 cutaneous melanoma], and 1 patient had no past history of cancer. Direct smears prepared from the patients' thyroid FNAs were fixed in 95% ethanol and stained with the Papanicolaou method. In 3 cases, immunostaining of the aspirated tumor cells with thyroglobulin antibody was performed, and in 1 case an aspiration smear was stained with commercial HMB-45 antibody. A correct cytodiagnosis of metastatic cancer to the thyroid was made in all 5 cases. In 1 patient the thyroid FNA revealed a metastatic RCC that led to the discovery of a clinically occult RCC. All 5 patients died of metastatic disease 27 to 40 months after surgical resection of their SMCTs.

  16. The reliability of fine-needle aspiration biopsy in terms of malignancy in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Kapan, Murat; Onder, Akin; Girgin, Sadullah; Ulger, Burak Veli; Firat, Ugur; Uslukaya, Omer; Oguz, Abdullah

    2015-02-01

    The aim of this study was to analyze the presence of malignancy in patients with Hashimoto's thyroiditis and to investigate the reliability of preoperative fine-needle aspiration biopsy (FNAB). The retrospective study included 44 patients who were operated on for nodular goiter between December 2010 and October 2011. The patients underwent thyroidectomy following a cytologic analysis plus FNAB. Hashimoto's thyroiditis was confirmed on histopathology in all patients. FNAB results were defined as benign in 14 (31.8%), suspicion for malignancy in 17 (38.6%), malignant in 9 (20.5%), and inadequate in 4 (9.1%). Following the thyroidectomy, presence of papillary thyroid carcinoma and follicular variant of papillary thyroid carcinoma were detected in 10 patients (22.7%) and 1 (2.3%) patient, respectively. The FNAB results were interpreted in terms of malignancy, which revealed the sensitivity as 80%; specificity, 40%; false positives, 69.2%; false negatives, 14.3%; positive predictive value, 31.8%; negative predictive value, 85.7%; and diagnostic accuracy, 50%. The coexistence of Hashimoto's thyroiditis with papillary thyroid carcinoma is quite common. The FNAB results for such cases are hard to evaluate, and they are likely to increase the number of false positives.

  17. Ultrasonography-guided core needle biopsy for the thyroid nodule: does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results?

    Science.gov (United States)

    Hahn, S Y; Han, B-K; Ko, E Y; Ko, E S

    2013-01-01

    Objective: We evaluated the diagnostic role of ultrasonography-guided core needle biopsy (CNB) according to ultrasonography features of thyroid nodules that had inconclusive ultrasonography-guided fine-needle aspiration (FNA) results. Methods: A total of 88 thyroid nodules in 88 patients who underwent ultrasonography-guided CNB because of previous inconclusive FNA results were evaluated. The patients were classified into three groups based on ultrasonography findings: Group A, which was suspicious for papillary thyroid carcinoma (PTC); Group B, which was suspicious for follicular (Hurthle cell) neoplasm; and Group C, which was suspicious for lymphoma. The final diagnoses of the thyroid nodules were determined by surgical confirmation or follow-up after ultrasonography-guided CNB. Results: Of the 88 nodules, the malignant rate was 49.1% in Group A, 12.0% in Group B and 90.0% in Group C. The rates of conclusive ultrasonography-guided CNB results after previous incomplete ultrasonography-guided FNA results were 96.2% in Group A, 64.0% in Group B and 90.0% in Group C (p=0.001). 12 cases with inconclusive ultrasonography-guided CNB results were finally diagnosed as 8 benign lesions, 3 PTCs and 1 lymphoma. The number of previous ultrasonography-guided FNA biopsies was not significantly different between the conclusive and the inconclusive result groups of ultrasonography-guided CNB (p=0.205). Conclusion: Ultrasonography-guided CNB has benefit for the diagnosis of thyroid nodules with inconclusive ultrasonography-guided FNA results. However, it is still not helpful for the differential diagnosis in 36% of nodules that are suspicious for follicular neoplasm seen on ultrasonography. Advances in knowledge: This study shows the diagnostic contribution of ultrasonography-guided CNB as an alternative to repeat ultrasonography-guided FNA or surgery. PMID:23564885

  18. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study

    DEFF Research Database (Denmark)

    Mortensen, M B; Pless, T; Durup, J

    2001-01-01

    BACKGROUND AND STUDY AIMS: Several studies have evaluated the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) in the upper gastrointestinal tract, but so far no studies have specifically evaluated the clinical impact of EUS-FNAB in upper gastrointestinal tract......% in esophageal, gastric, and pancreatic cancer, respectively. The staging-related clinical impact was similar for all three types of cancer (11-12.5%), whereas the diagnosis-related impact was highest in pancreatic cancer patients (86%). EUS-FNAB was inadequate in 13% and gave false-negative results in 5......%. The overall sensitivity, specificity and accuracy for EUS-FNAB were 80%, 78% and 80%, respectively. No complications related to the biopsy procedure were seen. CONCLUSIONS: If EUS-FNAB was performed only in cases where a positive malignant result would change patient management, then approximately one out...

  19. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.

    Science.gov (United States)

    Siddiqui, Ali A; Brown, Lauren J; Hong, Shih-Kuang S; Draganova-Tacheva, Rossitza A; Korenblit, Jason; Loren, David E; Kowalski, Thomas E; Solomides, Charalambos

    2011-11-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size 4 cm was 40, 75.9, 86.9, 93

  20. A microfluidic needle for sampling and delivery of chemical signals by segmented flows

    Science.gov (United States)

    Feng, Shilun; Liu, Guozhen; Jiang, Lianmei; Zhu, Yonggang; Goldys, Ewa M.; Inglis, David W.

    2017-10-01

    We have developed a microfluidic needle-like device that can extract and deliver nanoliter samples. The device consists of a T-junction to form segmented flows, parallel channels to and from the needle tip, and seven hydrophilic capillaries at the tip that form a phase-extraction region. The main microchannel is hydrophobic and carries segmented flows of water-in-oil. The hydrophilic capillaries transport the aqueous phase with a nearly zero pressure gradient but require a pressure gradient of 19 kPa for mineral oil to invade and flow through. Using this device, we demonstrate the delivery of nanoliter droplets and demonstrate sampling through the formation of droplets at the tip of our device. During sampling, we recorded the fluorescence intensities of the droplets formed at the tip while varying the concentration of dye outside the tip. We measured a chemical signal response time of approximately 3 s. The linear relationship between the recorded fluorescence intensity of samples and the external dye concentration (10-40 μg/ml) indicates that this device is capable of performing quantitative, real-time measurements of rapidly varying chemical signals.

  1. The value of thyroglobulin in washout of fine needle aspirate from 16 cervical lesions in patients with thyroid cancer.

    Science.gov (United States)

    Familiar Casado, Cristina; Antón Bravo, Teresa; Moraga Guerrero, Inmaculada; Ramos Carrasco, Araceli; García García, Carmen; Villanueva Curto, Santiago

    2013-11-01

    Thyroglobulin in the needle washout (Tg-FNA) and cytology of fine needle aspiration (cyto-FNA) are recommended for diagnosis of metastatic lymphadenopathies and recurrence of differentiated thyroid cancer. The objective of this study was to assess the value of these procedures in 16 cervical masses from patients with thyroid cancer of the follicular epithelium (TC). The study included six patients with TC and cervical lymphadenopathies evaluated before initial thyroid surgery and 10 patients followed up after TC surgery with cervical lumps discovered. FNA was performed in all 16 masses. Results of cyto-FNA, Tg-FNA and of the combined tests were compared to the final diagnosis of each lesion. Among 10 lesions proven to be malignant at surgery, cyto-FNA, Tg-FNA and the combination of both allowed for adequate diagnosis in 7, 9, and 10 cases respectively. Among 6 lesions considered to be benign, cyto-FNA was able to confirm diagnosis in 4, was non-diagnostic in one, and was falsely negative in the remaining case, while Tg-FNA was below the established cut-off value (to consider malignancy) in all cases. In patients with TC and suspect cervical masses, Tg-FNA improved the diagnostic yield of cyto-FNA alone, thus warranting its routine recommendation when FNA is performed. However, universal standardization of the technique and definition of valid cut-off thyroglobulin values (depending on the immunoassay used) above which the lesion should be considered to be malignant are still pending. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  2. Assessment of pain score and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy of thyroid nodules

    Directory of Open Access Journals (Sweden)

    Liao LJ

    2017-12-01

    Full Text Available Li-Jen Liao,1 Wu-Chia Lo,1 Wan-Lun Hsu,2 Po-Wen Cheng,1 Cheng-Ping Wang3 1Department of Otolaryngology, Far Eastern Memorial Hospital, 2Genomics Research Center, Academia Sinica, 3Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan, Republic of China Objective: The aim of this study was to evaluate pain scores and specimen adequacy for ultrasound-guided fine-needle aspiration biopsy (US-FNAB of thyroid nodules without and with local anesthesia (LA. Materials and methods: The US-FNAB procedure was performed on 183 patients with and without LA. One puncture was made for solid nodules, and if patients could tolerate it, a two-puncture technique was used for nodules with a cystic change. Four-point verbal rating scores were assessed by a nursing assistant after completion of US-FNAB. To be an adequate specimen, at least six groups of follicular cells are required, and each group should contain at least 10 cells.Results: Immediately after US-FNAB, 92% of patients with LA and 80% without LA reported no or mild pain (p=0.01. Most patients tolerated the procedure well, with no pain (82.5% reported 5 minutes after the procedure. In univariate logistic regression, irregular boundary (odds ratio [OR]: 2.52, 95% confidence interval [CI]: 1.04–6.06, p=0.04, calcification (OR: 2.86, 95% CI: 1.06–7.76, p=0.04, and LA (OR: 0.35, 95% CI: 0.15–0.86, p=0.02 were significantly associated with immediate moderate or severe pain. Specimen adequacy was significantly associated with age (OR: 0.95, 95% CI: 0.92–0.97, p<0.01, heterogeneous echo-texture (OR: 1.76, 95% CI: 1.23–5.17, p=0.01, predominate solid architecture (OR: 2.78, 95% CI: 1.42–5.41, p<0.01, and the use of LA (OR: 3.34, 95% CI: 1.70–6.56, p<0.01. In multivariate logistic regression, patients receiving LA had lower risk of moderate or severe pain (OR: 0.25, 95% CI: 0.09–0.67, p=0.01 and higher chances of specimen adequacy (OR: 4.84, 95% CI: 2.17–10.7, p<0

  3. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  4. Primary splenic angiosarcoma with liver metastasis: A rare neoplasm diagnosed on fine-needle aspiration cytology and cell block immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Saniya Sharma

    2018-01-01

    Full Text Available Primary splenic angiosarcoma is a rare malignant vascular neoplasm of mesenchymal origin. The tumor is highly aggressive and has a high metastatic potential. It is usually diagnosed on histopathological examination of splenectomy specimen. Only few cases of angiosarcoma diagnosed by fine-needle aspiration (FNA cytology alone have been reported in the literature. The cytologic features of angiosarcoma are heterogeneous, however, diagnosis can be suggested by FNA when vasoformative features are present. A 55-year-old female presented with abdominal pain and hepatosplenomegaly. Computed tomography scan revealed a heterogeneous splenic lesion with liver metastases. FNA from the splenic and liver lesions showed moderately pleomorphic tumor cells closely associated with anastomosing vascular channels. Cell block immunocytochemistry (ICC showed tumor cells positive for CD31, CD34, CD68 as well as for CD99. FNA supplemented by cell block ICC can render a definite diagnosis of primary splenic angiosarcoma with liver metastasis.

  5. Effect of a Biopsy Center on Adequacy Rates of Thyroid Nodule Fine-Needle Aspiration.

    Science.gov (United States)

    Leung, Vincent A; Kirpalani, Anish; Mnatzakanian, Gevork; Colak, Errol; Vlachou, Paraskevi A

    2017-08-01

    The purpose of this study was to investigate the effect of a biopsy center-a dedicated space with a dedicated ultrasound machine and technologist, staffed daily by a radiologist responsible for performing ultrasound-guided procedures only-on the rate of non-diagnostic or unsatisfactory thyroid fine-needle aspiration (FNA). Three radiologists performed FNA on 1200 nodules in 998 patients between September 2010 and November 2015. We compared rates of nondiagnostic or unsatisfactory FNA before and after implementation of a biopsy center in September 2014 as part of a quality improvement initiative. Before the establishment of our biopsy center, ultrasound-guided procedures were scheduled between diagnostic studies in the main ultrasound department and were performed by a radiologist responsible for both. Multivariate logistic regression analysis was performed to assess the effect of the biopsy center on the odds of obtaining an adequate sample. Rates of nondiagnostic or unsatisfactory FNA decreased significantly from 15.1% to 8.5% (p < 0.001) after implementation of the biopsy center. The odds of obtaining an adequate sample were higher in the biopsy center (odds ratio, 2.07; 95% CI, 1.43-3.01), even after adjusting for patient age, nodule size, the radiologist performing the procedure, and time over the study period. The implementation of a biopsy center was associated with significantly lower rates of nondiagnostic or unsatisfactory thyroid FNA, suggesting target rates of 10% or lower are achievable with quality improvement measures.

  6. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    Science.gov (United States)

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  7. Accuracy of frozen-section combined with imprint and fine needle aspiration biopsy in thyroid nodules

    Directory of Open Access Journals (Sweden)

    Benyamin Makes

    2007-06-01

    Full Text Available Thyroid malignancy can be found on 5% of thyroid nodules. In order to better managed of thyroid nodules, skills to differentiate benign from malignant cases were needed. Fine needle aspiration biopsy (FNAB was done preoperatively while frozen section (FS and imprint cytology (IC should be done intra-operatively. The objective of this research paper is to evaluate the diagnostic accuracy of FNAB versus frozen section combined with imprint cytology (FS+IC in thyroid nodules at the Anatomic-Pathology Department FMUI-CM Hospital, Jakarta. This diagnostic test, used data from clinico-pathological records in Anatomic Pathology Department, Faculty of Medicine University of Indonesia / Dr.Cipto Mangunkusumo General Hospital, Jakarta, Indonesia during 1999-2003. Specimens with complete data of FNAB results, data of FS and slides of IC. All formalin fixed`specimens were reevaluated and used as the golden standard. Sensitivity, spesificity and accuracy of FS+IC were higher than FNAB (86.8% vs 73.7% ; 99.0% vs 83.9% ; 94.8% vs 80.5% respectively. If the results of FNAB were concordant with the result of FS+IC, the combined examination yields accuracy of 95.1%. The evaluation of frozen section combined with imprint cytology is very useful, because this examination significantly showed high accuracy in diagnosing thyroid malignancy. (Med J Indones 2007; 16:89-93Keywords: thyroid nodules, FNAB, frozen section, imprint cytology, accuracy

  8. ADM3, TFF3 and LGALS3 are discriminative molecular markers in fine-needle aspiration biopsies of benign and malignant thyroid tumours

    Science.gov (United States)

    Karger, S; Krause, K; Gutknecht, M; Schierle, K; Graf, D; Steinert, F; Dralle, H; Führer, D

    2012-01-01

    Background: Previously, we reported a six-marker gene set, which allowed a molecular discrimination of benign and malignant thyroid tumours. Now, we evaluated these markers in fine-needle aspiration biopsies (FNAB) in a prospective, independent series of thyroid tumours with proven histological outcome. Methods: Quantitative RT–PCR was performed (ADM3, HGD1, LGALS3, PLAB, TFF3, TG) in the needle wash-out of 156 FNAB of follicular adenoma (FA), adenomatous nodules, follicular and papillary thyroid cancers (TC) and normal thyroid tissues (NT). Results: Significant expression differences were found for TFF3, HGD1, ADM3 and LGALS3 in FNAB of TC compared with benign thyroid nodules and NT. Using two-marker gene sets, a specific FNAB distinction of benign and malignant tumours was achieved with negative predictive values (NPV) up to 0.78 and positive predictive values (PPV) up to 0.84. Two FNAB marker gene combinations (ADM3/TFF3; ADM3/ACTB) allowed the distinction of FA and malignant follicular neoplasia with NPV up to 0.94 and PPV up to 0.86. Conclusion: We demonstrate that molecular FNAB diagnosis of benign and malignant thyroid tumours including follicular neoplasia is possible with recently identified marker gene combinations. We propose multi-centre FNAB studies on these markers to bring this promising diagnostic tool closer to clinical practice. PMID:22223087

  9. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    Science.gov (United States)

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  10. Next-generation sequencing for molecular diagnosis of lung adenocarcinoma specimens obtained by fine needle aspiration cytology

    Science.gov (United States)

    Qiu, Tian; Guo, Huiqin; Zhao, Huan; Wang, Luhua; Zhang, Zhihui

    2015-06-01

    Identification of multi-gene variations has led to the development of new targeted therapies in lung adenocarcinoma patients, and identification of an appropriate patient population with a reliable screening method is the key to the overall success of tumor targeted therapies. In this study, we used the Ion Torrent next-generation sequencing (NGS) technique to screen for mutations in 89 cases of lung adenocarcinoma metastatic lymph node specimens obtained by fine-needle aspiration cytology (FNAC). Of the 89 specimens, 30 (34%) were found to harbor epidermal growth factor receptor (EGFR) kinase domain mutations. Seven (8%) samples harbored KRAS mutations, and three (3%) samples had BRAF mutations involving exon 11 (G469A) and exon 15 (V600E). Eight (9%) samples harbored PIK3CA mutations. One (1%) sample had a HRAS G12C mutation. Thirty-two (36%) samples (36%) harbored TP53 mutations. Other genes including APC, ATM, MET, PTPN11, GNAS, HRAS, RB1, SMAD4 and STK11 were found each in one case. Our study has demonstrated that NGS using the Ion Torrent technology is a useful tool for gene mutation screening in lung adenocarcinoma metastatic lymph node specimens obtained by FNAC, and may promote the development of new targeted therapies in lung adenocarcinoma patients.

  11. Image-guided fine needle cytology with aspiration versus non-aspiration in retroperitoneal masses: is aspiration necessary?

    Science.gov (United States)

    Misra, Rajiv Kumar; Mitra, Shaila; Jain, Rishav Kumar; Vahikar, Shilpa; Bundela, Archana; Misra, Purak

    2015-03-01

    Although using fine needle cytology with aspiration (FNC-A) for establishing diagnoses in the retroperitoneal region has shown promise, there is scant literature supporting a role of non-aspiration cytology (FNC-NA) for this region. We assessed the accuracy and reliability of FNC-A and FNC-NA as tools for preoperative diagnosis of retroperitoneal masses and compared the results of both techniques with each other and with histopathology. Fifty-seven patients with retroperitoneal masses were subjected to FNC-A and FNC-NA. Smears were stained with May-Grunwald Giemsa and hematoxylin and eosin stain. An individual slide was objectively analysed using a point scoring system to enable comparison between FNC-A and FNC-NA. By FNC-A, 91.7% accuracy was obtained in cases of retroperitoneal lymph node lesions followed by renal masses (83.3%). The diagnostic accuracy of other sites by FNC-A varied from 75.0%-81.9%. By FNC-NA, 93.4% diagnostically accurate results were obtained in the kidney, followed by 75.0% in adrenal masses. The diagnostic accuracy of other sites by FNC-NA varied from 66.7%-72.8%. Although both techniques have their own advantages and disadvantages, FNC-NA may be a more efficient adjuvant method of sampling in retroperitoneal lesions.

  12. Fine needle aspiration cytology in symptomatic breast lesions: still an important diagnostic modality?

    LENUS (Irish Health Repository)

    Smith, Myles J

    2012-01-01

    The objective of this study was to make an assessment of the utility of fine needle aspiration cytology (FNAC), in a "one-stop" symptomatic breast triple assessment clinic. Controversy surrounds the optimal tissue biopsy methodology in the diagnosis of symptomatic breast cancer and the identification of benign disease. FNAC in the context of a Rapid Assessment Breast Clinic (RABC) allows the same day diagnosis and early treatment of breast cancer, with the immediate reassurance and discharge of those with benign disease. We analyzed prospective data accrued at a RABC, over a 4-year period from 2004 to 2007. All patients were triple assessed, with FNACs performed on site by two consultant cytopathologists. Investigations were reported immediately, and clinical data were captured via a database using compulsory data field entry. There were 4487 attendances at our RABC, with 1572 FNACs were performed. The positive predictive value of FNAC with a C5 cancer diagnosis was 100%, 95.6% for a C4 report, with a complete sensitivity of 94%. The full specificity of correctly identified benign lesions was 77.4%, with a false negative rate of 3.85%. This enabled 66% of patients attending the RABC to receive a same day diagnosis of benign disease and discharge. FNAC is highly accurate in the diagnosis of symptomatic breast cancer in an RABC. FNAC allows accurate diagnosis of benign disease and immediate discharge of the majority of patients. In this era, when a large majority of patients have benign disease, we believe that FNAC provides an equivalent, if not better, method of evaluation of patients in a triple assessment RABC.

  13. Can a virtual reality assessment of fine motor skill predict successful central line insertion?

    Science.gov (United States)

    Mohamadipanah, Hossein; Parthiban, Chembian; Nathwani, Jay; Rutherford, Drew; DiMarco, Shannon; Pugh, Carla

    2016-10-01

    Due to the increased use of peripherally inserted central catheter lines, central lines are not performed as frequently. The aim of this study is to evaluate whether a virtual reality (VR)-based assessment of fine motor skills can be used as a valid and objective assessment of central line skills. Surgical residents (N = 43) from 7 general surgery programs performed a subclavian central line in a simulated setting. Then, they participated in a force discrimination task in a VR environment. Hand movements from the subclavian central line simulation were tracked by electromagnetic sensors. Gross movements as monitored by the electromagnetic sensors were compared with the fine motor metrics calculated from the force discrimination tasks in the VR environment. Long periods of inactivity (idle time) during needle insertion and lack of smooth movements, as detected by the electromagnetic sensors, showed a significant correlation with poor force discrimination in the VR environment. Also, long periods of needle insertion time correlated to the poor performance in force discrimination in the VR environment. This study shows that force discrimination in a defined VR environment correlates to needle insertion time, idle time, and hand smoothness when performing subclavian central line placement. Fine motor force discrimination may serve as a valid and objective assessment of the skills required for successful needle insertion when placing central lines. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Diagnostic pitfalls associated with fine-needle aspiration biopsy in a patient with the myxoid variant of monophasic fibrous synovial sarcoma.

    Science.gov (United States)

    Bergman, Simon; Brownlee, Noel A; Geisinger, Kim R; Ward, William G; Pettenati, Mark J; Koty, Patrick; Ellis, Ezra; Beaty, Michael W; Kilpatrick, Scott E

    2006-11-01

    Synovial sarcoma (SS) is one of the most common soft tissue tumors that typically presents in the extremities of young adults, but may occur at any site and affect children during the first decade. Herein we discuss a 12-yr-old male who complained of left foot pain and plantar mass. A fine-needle aspiration biopsy of an 8 cm subcutaneous mass was performed revealing a myxoid spindle cell neoplasm. The cytologic differential diagnosis included a myxoid neurofibroma, neurothekeoma, and a myxoid sarcoma. Subsequent excision of the mass revealed a monophasic fibrous SS with myxoid features. Examination of the tissue by fluorescence in situ hybridization confirmed the presence of characteristic SS SYT gene rearrangement at chromosome 18q11.2. This case underscores that the cytologic distinction of mxyoid spindle cell tumors may be challenging. We report the cytologic features of a myxoid monophasic fibrous SS, and discuss its distinction from other benign and malignant myxoid soft tissue neoplasms. (C) 2006 Wiley-Liss, Inc.

  15. On the performance of capillary barriers as landfill cover

    Science.gov (United States)

    Kämpf, M.; Montenegro, H.

    Landfills and waste heaps require an engineered surface cover upon closure. The capping system can vary from a simple soil cover to multiple layers of earth and geosynthetic materials. Conventional design features a compacted soil layer, which suffers from drying out and cracking, as well as root and animal intrusion. Capillary barriers consisting of inclined fine-over-coarse soil layers are investigated as an alternative cover system. Under unsaturated conditions, the textural contrast delays vertical drainage by capillary forces. The moisture that builds up above the contact will flow downdip along the interface of the layers. Theoretical studies of capillary barriers have identified the hydraulic properties of the layers, the inclination angle, the length of the field and the infiltration rate as the fundamental characteristics of the system. However, it is unclear how these findings can lead to design criteria for capillary barriers. To assess the uncertainty involved in such approaches, experiments have been carried out in a 8 m long flume and on large scale test sites (40 m x 15 m). In addition, the ability of a numerical model to represent the relevant flow processes in capillary barriers has been examined.

  16. On the performance of capillary barriers as landfill cover

    Directory of Open Access Journals (Sweden)

    M. Kämpf

    1997-01-01

    Full Text Available Landfills and waste heaps require an engineered surface cover upon closure. The capping system can vary from a simple soil cover to multiple layers of earth and geosynthetic materials. Conventional design features a compacted soil layer, which suffers from drying out and cracking, as well as root and animal intrusion. Capillary barriers consisting of inclined fine-over-coarse soil layers are investigated as an alternative cover system. Under unsaturated conditions, the textural contrast delays vertical drainage by capillary forces. The moisture that builds up above the contact will flow downdip along the interface of the layers. Theoretical studies of capillary barriers have identified the hydraulic properties of the layers, the inclination angle, the length of the field and the infiltration rate as the fundamental characteristics of the system. However, it is unclear how these findings can lead to design criteria for capillary barriers. To assess the uncertainty involved in such approaches, experiments have been carried out in a 8 m long flume and on large scale test sites (40 m x 15 m. In addition, the ability of a numerical model to represent the relevant flow processes in capillary barriers has been examined.

  17. Malignant nodular hidradenoma on the scalp: report of a case with fine needle aspiration cytology features and histologic correlation.

    Science.gov (United States)

    Garcia-Bonafe, María Magdalena; Campins, Maria M Company; Redecilla, Pere Huguet

    2009-01-01

    Malignant nodular hidradenoma (MNH) is a malignant adnexal tumor of the eccrine sweat glands. The histology is similar to that of benign nodular hidradenoma, but MNH shows an infiltrative and invasive pattern, necrosis and angiolymphatic invasion. A 60-year-old woman, diagnosed with rectal adenocarcinoma 6 months before, underwent fine needle aspiration (FNA) of a nodule on the scalp. The aspirate smears showed (1) necrotic debris; (2) cohesive cell clusters and tissue fragments; (3) tubular formations; (4) globoid or cylindrical clear cells; (5) cells showing dense cytoplasm and a basaloid appearance; (6) cell sheets with anaplasia and squamous differentiation; and (7) multinucleated giant cells. The histology showed a lobulated pattern with necrosis and cyst formation. The clear cells that were seen on cytology occupied the periphery of the lobules, whereas the anaplastic cells were located in the central portion. Squamous differentiation and tubular formations were observed. Rapid, accurate diagnosis of these tumors is important, particularly when they develop at sites where a metastatic process must be ruled out. Cytology of FNA material provides this capability.

  18. Thyroid Fine Needle Aspiration Biopsies in Children: Study of Cytological-Histological Correlation and Immunostaining with Thyroid Peroxidase Monoclonal Antibodies

    Directory of Open Access Journals (Sweden)

    Bauer Andrew

    2010-05-01

    Full Text Available Context. There is limited data comparing results of fine needle aspiration biopsies (FNABs to histological diagnosis in children. Design. FNABs were performed in 707 children and cytological results were compared to histology in 165 cases. The usefulness of immunostaining with anti-TPO monoclonal antibodies (MoAb47 on FNAB samples was examined in 54 operated patients. Results. Among unsatisfactory, benign, suspicious, and malignant FNAB, the histological diagnoses were benign in 12/12 (100%, 69/70 (98.5%, 40/50 (80.0%, and 0/33 (0%, respectively. After surgery, malignancy was established in 44/165 (26.6% cases. The sensitivity, specificity, and positive and negative predictive values were 95.4%, 55.8%, 61.7%, and 95% with standard FNAB; and 100%, 75%, 73.3, and 100% with MoAb47. Among suspicious FNAB, positive MoAb47 staining was a reliable marker for exclusion of malignancy. Conclusion. Benign and malignant FNAB accurately predict histological diagnosis. In suspicious FNAB, MoAb47 immunostaining may be a useful adjunct to standard cytology.

  19. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  20. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  1. Catering to millennial learners: assessing and improving fine-needle aspiration performance.

    Science.gov (United States)

    Rowse, Phillip G; Ruparel, Raaj K; AlJamal, Yazan N; Abdelsattar, Jad M; Heller, Stephanie F; Farley, David R

    2014-01-01

    Fine-needle aspiration (FNA) of a palpable cervical lymph node is a straightforward procedure that should be safely performed by educated general surgery (GS) trainees. Retention of technical skill is suspect, unless sequential learning experiences are provided. However, voluntary learning experiences are no guarantee that trainees will actually use the resource. A 3-minute objective structured assessment of technical skill-type station was created to assess GS trainee performance using FNA. Objective criteria were developed and a checklist was generated (perfect score = 24). Following abysmal performance of 11 postgraduate year (PGY)-4 trainees on the FNA station of our semiannual surgical skills assessment ("X-Games"), we provided all GS residents with electronic access to a 90-second YouTube video clip demonstrating proper FNA technique. PGY-2 (n = 11) and PGY-3 (n = 10) residents subsequently were tested on FNA technique 5 and 12 days later, respectively. All 32 trainees completed the station in less than 3 minutes. Overall scores ranged from 4 to 24 (mean = 14.9). PGY-4 residents assessed before the creation of the video clip scored lowest (range: 4-18, mean = 11.4). PGY-3 residents (range: 10-22, mean = 17.8) and PGY-2 residents (range: 10-24, mean = 15.8) subsequently scored higher (p < 0.05). Ten residents admitted watching the 90-second FNA video clip and scored higher (mean = 21.7) than the 11 residents that admitted they did not watch the clip (mean = 13.1, p < 0.001). Of the 11 trainees who did not watch the video, 6 claimed they did not have time, and 5 felt it would not be useful to them. Overall performance of FNA was poor in 32 midlevel GS residents. However, a 90-second video clip demonstrating proper FNA technique viewed less than 2 weeks before the examination significantly elevated scores. Half of trainees given the chance to learn online did not take the opportunity to view the video clip. Although preemptive learning is effective, future

  2. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  3. CD 99 immunocytochemistry in solid pseudopapillary tumor of pancreas: A study on fine-needle aspiration cytology smears.

    Science.gov (United States)

    Ghosh, Ranajoy; Mallik, Saumya R; Mathur, Sandeep R; Iyer, Venkateswaran K

    2013-07-01

    Solid pseudopapillary tumor of pancreas (SPTP) is a rare pancreatic tumor of uncertain histogenesis usually affecting young women. Though these tumors have characteristic cytomorphology, it is sometimes difficult to differentiate them from neuroendocrine tumors of the pancreas. We reviewed cases of SPTP to delineate the diagnostic cytological features and also observed utility of CD 99 (MIC 2) immunostaining to aid in the diagnosis of this tumor. This study was designed to demonstrate the utility of CD 99 immunostaining along with cytological features for making a pre-operative diagnosis and delineating it from the neuroendocrine tumor of pancreas which is a close mimic. Cytomorphological features of 11 cases of solid pseudopapillary neoplasm diagnosed by pre-operative fine-needle aspiration cytology (FNAC) at our institute were reviewed. Immunocytochemistry for CD 99 was also performed on the smears. All the cases had cellular smears with monomorphic cells lying singly, as loosely cohesive clusters as well as forming delicate pseudopapillae. Presence of intra and extra-cellular basement membrane material, background foamy macrophages and nuclear grooves were the other salient features. Immunocytochemistry for CD 99 could be performed on eight cases and demonstrated typical paranuclear dot-like positivity. Pre-operative early diagnosis of SPTP can be made by FNAC which can further be aided by CD 99 immunocytochemistry.

  4. The value of ultrasound with ultrasound-guided fine-needle aspiration biopsy compared to computed tomography in the detection of regional metastases in the clinically negative neck

    International Nuclear Information System (INIS)

    Takes, Robert P.; Righi, Paul; Meeuwis, Cees A.; Manni, Johannes J.; Knegt, Paul; Marres, Henri A.M.; Spoelstra, Hubert A.A.; Boer, Maarten F. de; Mey, Andel G.L. van der; Bruaset, I.; Ball, Valerie; Weisberger, Edward; Radpour, Shokri; Kruyt, Rene H.; Joosten, Frank B.M.; Lameris, Johan S.; Oostayen, Jacques A. van; Kopecky, Kenyon; Caldemeyer, Karen; Henzen-Logmans, Sonja C.; Wiersma-van Tilburg, J.M.; Bosman, Fred T.; Krieken, J. Han J.M. van; Hermans, Jo; Baatenburg de Jong, Robert J.

    1998-01-01

    Purpose: Head and neck oncologists have not reached consensus regarding the role of contemporary imaging techniques in the evaluation of the clinically negative neck in patients with head and neck squamous cell carcinoma (HNSCC). The purpose of the present study was to compare the accuracy of ultrasound with guided fine-needle aspiration biopsy (UGFNAB) and computed tomography (CT) in detecting lymph node metastasis in the clinically negative neck. Methods and Materials: Sixty-four neck sides of patients with HNSCC were examined preoperatively by ultrasound/UGFNAB and CT at one of five participating tertiary care medical centers. The findings were correlated with the results of histopathologic examination of the neck specimen. Results: Ultrasound with guided fine-needle aspiration biopsy was characterized by a sensitivity of 48%, specificity of 100%, and overall accuracy of 79%. Three cases had nondiagnostic aspirations using UGFNAB and were excluded. CT demonstrated a sensitivity of 54%, specificity of 92%, and overall accuracy of 77%. UGFNAB detected two additional metastases not visualized on CT, whereas CT detected no metastases not seen on UGFNAB. The results of UGFNAB were similar between the participating centers. Conclusions: Approximately one half of the clinically occult nodal metastases in our patient group were identified by both CT and UGFNAB. Overall, UGFNAB and CT demonstrated comparable accuracy. The sensitivity of CT was slightly better than UGFNAB, but the latter remained characterized by a superior specificity. The results of CT and UGFNAB did not appear to be supplementary. The choice of imaging modality for staging of the clinically negative neck depends on tumor site, T-stage, and experience and preference of the head and neck oncologist. If CT is required for staging of the primary tumor, additional staging of the neck by UGFNAB does not provide significant additional value

  5. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  6. Sonographic features and ultrasonography-guided fine-needle aspiration of metastases to the thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun; Kim, Eun Kyung; Kwak, Jin Young; Moon, Hee Jung; Kim, Ga Ram [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    To evaluate the characteristic ultrasonographic (US) features of metastatic carcinoma to the thyroid, and how accurate US features and ultrasonography-guided fine-needle aspiration (US-FNA) are for the diagnosis of thyroid metastases. Twenty-three thyroid lesions in 23 patients (mean age, 66.7 years; range, 46 to 85 years) that had been diagnosed as thyroid metastases were included. The composition, echogenicity, margin, shape, presence of calcifications, underlying parenchymal echotexture, and vascularity were analyzed in US images of the thyroid metastases. Final US assessments were categorized into probably benign and suspicious malignancy. The presence of suspicious metastatic cervical lymph nodes was noted. The medical records, US-FNA cytology, and pathology reports of these patients were retrospectively reviewed. Of the 23 thyroid lesions, the general US appearance was mass-forming in 21 (91.3%) and non-mass-forming in 2 (8.7%). All 23 lesions showed a solid tumor composition. Common US features among the 21 mass-forming thyroid metastases were hypoechogenicity (81.0%), non-circumscribed margins (90.5%), no calcifications (76.2%), and parallel shape (81.0%). Suspicious cervical lymph nodes were present in 18 patients (78.3%). Of the 23 lesions, 21 (91.3%) were classified as suspicious malignancy, and 2 (8.7%) as probably benign. US-FNA showed diagnostic results specific for metastases in 21 of the 22 patients (95.5%) who had undergone US-FNA. Common US features in thyroid metastasis were hypoechogenicity, non-circumscribed margins, no calcifications, parallel shape, and the presence of suspicious cervical lymph nodes. US-FNA can be effectively used in the diagnosis of thyroid metastasis, preventing unnecessary surgery.

  7. Diagnostic accuracy of fine needle aspiration cytology of thyroid and evaluation of discordant cases

    International Nuclear Information System (INIS)

    Sharma, Ch.

    2015-01-01

    The main role of fine needle aspiration cytology (FNAC) lies in differentiating between a malignant and benign thyroid nodule. It greatly influences the treatment decision. The current study was undertaken to evaluate the cytology–histopathology correlation and to analyze the cause of diagnostic errors with an eventual aim to improve diagnostic accuracy. Materials and Methods This is a retrospective study comparing cytology and corresponding histopathology report in 724 thyroid cases. The statistical analysis included false positive rate, false negative rate, sensitivity, specificity, positive predictive value, negative predictive value and accuracy. Results On cytological examination, 635/724 were reported as benign, 68 malignant and 21 suspicious. On histopathological examination, 626/635 cases were confirmed as benign but there were 9 discordant cases. Among the other cases histopathology diagnosis of malignancy matched in 66/68 and 11/21 cases. Diagnosis correlated in 703/724 cases (97%) [p < 0.001]. False positive and false negative rates were 1.9% and 10.5%, respectively. The sensitivity and specificity were 89.5% and 98%, respectively. The positive predictive value was 84.6% and negative predictive value was 98.6%. Accuracy of FNA was 97%. Conclusion In spite of high accuracy of FNAC in differentiating between a benign and malignant lesion, certain pitfalls should be kept in mind. The common false negative diagnoses were follicular pattern cases which constitute a ‘gray zone’, cystic papillary thyroid carcinoma (PTC) and papillary micro carcinoma. The reason for false positive diagnoses was the occurrence of nuclear features characteristic of PTC in other thyroid lesions. Awareness of pathologist regarding these pitfalls can minimize false negative/positive diagnoses

  8. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  9. Prognostic utility of chromosomal instability detected by fluorescence in situ hybridization in fine-needle aspirates from oral squamous cell carcinomas

    International Nuclear Information System (INIS)

    Sato, Hiroaki; Uzawa, Narikazu; Takahashi, Ken-Ichiro; Myo, Kunihiro; Ohyama, Yoshio; Amagasa, Teruo

    2010-01-01

    Although chromosomal instability (CIN) has been detected in many kinds of human malignancies by means of various methods, there is no practical assessment for small clinical specimens. In this study, we evaluated CIN in fine-needle aspiration (FNA) biopsied oral squamous cell carcinomas (SCCs) using fluorescence in situ hybridization (FISH) analysis, and investigated its prognostic significance. To evaluate CIN status of tumors, FISH with genomic probes for the centromeres of chromosomes 7, 9, and 11 was performed on specimens obtained by FNA from 77 patients with primary oral SCCs. High-grade CIN (CIN3) was observed in 11.7% (9/77) of patients with oral SCCs and was associated significantly with reduced disease-free survival (p = .008) and overall survival (p = .003). Multivariate Cox proportional hazards analysis showed that CIN status was significantly correlated with disease-free survival (p = .035) and overall survival (p = .041). Analysis of CIN status using FISH on FNA biopsy specimens may be useful in predicting of recurrence and poor prognosis in patients with oral SCCs

  10. Fine needle aspiration cytology of bone tumours- the experience from the National Orthopaedic and Lagos University Teaching Hospitals, Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Nnodu Obiageli E

    2006-06-01

    Full Text Available Abstract Background Due to difficulty in confirming clinical suspicions of malignancy in patients presenting with bone tumours, the cost of surgical biopsies where hospital charges are borne almost entirely by patients, competition with bone setters and healing homes with high rate of loss to follow up; we set out to find if sufficient material could be obtained to arrive at reliable tissue diagnosis in patients with clinical and radiological evidence of bone tumours in our hospitals. Methods After initial clinical and plain radiographic examinations, patients were sent for fine needle aspirations. Aspirations were carried out with size 23G needles of varying lengths with 10 ml syringes in a syringe holder (CAMECO, Sebre Medical, Vellinge, Sweden. The aspirates were air dried, stained by the MGG method and examined microscopically. Histology was performed on patients who had subsequent surgical biopsy. These were then correlated with the cytology reports. Results Out of 96 patients evaluated, [57 males, 39 females, Mean age 31.52 years, Age Range 4–76 years,] material sufficient for diagnosis was obtained in 90 patients. Cytological diagnosis of benign lesions was made in 40 patients and malignant in 47. Of these, 27 were metastases, osteogenic sarcoma 16, giant cell tumour 19, infection 11. Histology was obtained in 41 patients. Correct diagnosis of benignity was made in 17 out of 18 cases, malignancy in 21 out of 22 cases. One non-diagnostic case was malignant. The accuracy of specific cytological diagnosis was 36/41 (87.8% and incorrect in 5/41 (12.2%. Conclusion We conclude that FNAC can be useful in the pre-operative assessment of bone tumours especially where other diagnostic modalities are unavailable.

  11. Capillary density and capillary-to-fibre ratio in vastus lateralis muscle of untrained and trained men

    Directory of Open Access Journals (Sweden)

    W. M. Kilarski

    2011-08-01

    Full Text Available Muscle fibre profile area (Af, volume density (Vv, capillary-to-fibre ratio (CF and number of capillaries per fibre square millimetre (CD were determined from needle biopsies of vastus lateralis of twenty-four male volunteers (mean ± SD: age 25.4±5.8 years, height 178.6±5.5 cm, body mass 72.1±7.7 kg of different training background. Seven subjects were untrained students (group A, nine were national and sub-national level endurance athletes (group B with the background of 7.8±2.9 years of specialised training, and eight subjects were sprint-power athletes (group C with 12.8±8.7 years of specialised training. Muscle biopsies of vastus lateralis were analysed histochemically for mATPase. Capillaries were visualized and counted using CD31 antibodies against endothelial cells. There were significant differences in the Vv of type I and type II muscle fibres in both trained groups, B (51.8%; 25.6% and C (50.5%; 26.4%. However, in untrained group A that was treated as a reference group, the difference between Vv of type I and type II fibres was less prominent, nevertheless statistically significant (42.1%; 35.1%. There was also a significant difference in CF: 1.9 in group A and 2.1 in groups B and C. The number of capillaries per mm2 (CD was 245 (group A, 308 (group B and 325 (group C. Significant differences (P<0.05 in CF and CD, were found only between group A (1.9; 245 and both groups of trained men, B and C (2.1; 308 and 325. However, endurance athletes (group B, such as long-distance runners, cyclists and cross country skiers, did not differ from the athletes representing short term, high power output sports (group C such as ice hockey, karate, ski-jumping, volleyball, soccer and modern dance.

  12. CT guided transthoracic fine needle aspiration biopsy (TFNAB) of the chest tumours; Transtorakalna biopsja aspiracyjna cienkoiglowa (TBAC) guzow umiejscowionych w klatce piersiowej pod kontrola obrazu tomografii komputerowej

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, J; Legaszewski, T; Skrzelewski, S; Sraga, W [Katedra i Zaklad Radiologii Lekarskiej i Radiodiagnostyki, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Zajecki, W [Katedra i Klinika Chirurgii Klatki Piersiowej, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Harasim, J [Katedra i Zaklad Patomorfologii, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland; Polonska, A [Katedra i Klinika Fizjopneumonologii, Zabrze (Poland); Slaska Akademia Medyczna, Katowice [Poland

    2003-07-01

    Tumours spreading within the chest are nowadays diagnosed based on computed tomography (CT). The aim of this paper is to present a few years experience in transthoracic fine needle aspiration biopsy of lung tumours and tumour-like lesions in adjacent tissues and organs during CT examination. To make an accurate diagnosis, the authors performed 124 TFNAB in 116 patients. About 2/3 of the biopsies were performed in patients with a tumour size from 1 to 5 cm in diameter, adjacent or located peripherally to the chest wall. The valuable cellular material, which enabled us to define a type of a disease and to make a final clinical diagnosis, was obtained in nearly 80% of cases. The complications were found in 10 patients (8.6% of all patients). Pneumothorax was found in eight cases and pulmonary bleeding (bleeding into pulmonary parenchyma and bleeding from respiratory duct) in two cases. The authors emphasized the significance of TFNAB in obtaining valuable material for fine spectrum study and discussed the problem of safety related to this procedure. (author)

  13. Influence of Adsorption of Foreign Gases on Mass Transfer in Fine (Nanoscale) Capillaries.

    Czech Academy of Sciences Publication Activity Database

    Levdansky, Valerij Vladimirovič; Pavlyukevich, N.V.; Izák, Pavel; Ždímal, Vladimír

    2016-01-01

    Roč. 47, č. 7 (2016), s. 691-699 ISSN 1064-2285 R&D Projects: GA ČR GA14-12695S Institutional support: RVO:67985858 Keywords : capillary * meniscus * evaporation Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.868, year: 2016

  14. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    Directory of Open Access Journals (Sweden)

    Agata Stanek-Widera

    2016-05-01

    Full Text Available Fine needle aspiration biopsy (FNA is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE. We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100% cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100% provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100% specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment indicates that repeat FNA in order to confirm the diagnosis is unnecessary.

  15. Thyroglobulin assay in fluids from lymph node fine needle-aspiration washout: influence of pre-analytical conditions.

    Science.gov (United States)

    Casson, Florence Boux de; Moal, Valérie; Gauchez, Anne-Sophie; Moineau, Marie-Pierre; Sault, Corinne; Schlageter, Marie-Hélène; Massart, Catherine

    2017-04-01

    The aim of this study was to evaluate the pre-analytical factors contributing to uncertainty in thyroglobulin measurement in fluids from fine-needle aspiration (FNA) washout of cervical lymph nodes. We studied pre-analytical stability, in different conditions, of 41 samples prepared with concentrated solutions of thyroglobulin (FNA washout or certified standard) diluted in physiological saline solution or buffer containing 6% albumin. In this buffer, over time, no changes in thyroglobulin concentrations were observed in all storage conditions tested. In albumin free saline solution, thyroglobulin recovery rates depended on initial sample concentrations and on modalities of their conservation (in conventional storage tubes, recovery mean was 56% after 3 hours-storage at room temperature and 19% after 24 hours-storage for concentrations ranged from 2 to 183 μg/L; recovery was 95%, after 3 hours or 24 hours-storage at room temperature, for a concentration of 5,656 μg/L). We show here that these results are due to non-specific adsorption of thyroglobulin in storage tubes, which depends on sample protein concentrations. We also show that possible contamination of fluids from FNA washout by plasma proteins do not always adequately prevent this adsorption. In conclusion, non-specific adsorption in storage tubes strongly contributes to uncertainty in thyroglobulin measurement in physiological saline solution. It is therefore recommended, for FNA washout, to use a buffer containing proteins provided by the laboratory.

  16. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  17. Improvement of the Mair scoring system using structural equations modeling for classifying the diagnostic adequacy of cytology material from thyroid lesions.

    Science.gov (United States)

    Kulkarni, H R; Kamal, M M; Arjune, D G

    1999-12-01

    The scoring system developed by Mair et al. (Acta Cytol 1989;33:809-813) is frequently used to grade the quality of cytology smears. Using a one-factor analytic structural equations model, we demonstrate that the errors in measurement of the parameters used in the Mair scoring system are highly and significantly correlated. We recommend the use of either a multiplicative scoring system, using linear scores, or an additive scoring system, using exponential scores, to correct for the correlated errors. We suggest that the 0, 1, and 2 points used in the Mair scoring system be replaced by 1, 2, and 4, respectively. Using data on fine-needle biopsies of 200 thyroid lesions by both fine-needle aspiration (FNA) and fine-needle capillary sampling (FNC), we demonstrate that our modification of the Mair scoring system is more sensitive and more consistent with the structural equations model. Therefore, we recommend that the modified Mair scoring system be used for classifying the diagnostic adequacy of cytology smears. Diagn. Cytopathol. 1999;21:387-393. Copyright 1999 Wiley-Liss, Inc.

  18. Artificial neural network model to distinguish follicular adenoma from follicular carcinoma on fine needle aspiration of thyroid.

    Science.gov (United States)

    Savala, Rajiv; Dey, Pranab; Gupta, Nalini

    2018-03-01

    To distinguish follicular adenoma (FA) and follicular carcinoma (FC) of thyroid in fine needle aspiration cytology (FNAC) is a challenging problem. In this article, we attempted to build an artificial neural network (ANN) model from the cytological and morphometric features of the FNAC smears of thyroid to distinguish FA from FC. The cytological features and morphometric analysis were done on the FNAC smears of histology proven cases of FA (26) and FC (31). The cytological features were analysed semi-quantitatively by two independent observers (RS and PD). These data were used to make an ANN model to differentiate FA versus FC on FNAC material. The performance of this ANN model was assessed by analysing the confusion matrix and receiving operator curve. There were 39 cases in training set, 9 cases each in validation and test sets. In the test group, ANN model successfully distinguished all cases (9/9) of FA and FC. The area under receiver operating curve was 1. The present ANN model is efficient to diagnose follicular adenoma and carcinoma cases on cytology smears without any error. In future, this ANN model will be able to diagnose follicular adenoma and carcinoma cases on thyroid aspirate. This study has immense potential in future. This is an open ended ANN model and more parameters and more cases can be included to make the model much stronger. © 2017 Wiley Periodicals, Inc.

  19. Percutaneous fine needle aspiration biopsy for the intrathoracic lesions: What is the meaning of non-diagnostic results?

    International Nuclear Information System (INIS)

    Kim, Min Ju; Lee, Jin Seong; Do, Kyung Hyun; Seo, Joon Beom; Song, Koun Sik; Lim, Tae Hwan

    2003-01-01

    To know what is the meaning of non-diagnostic results of fine needle aspiration biopsy (FNAB) and whether repeated aspiration is needed or not in those situations. We reviewed 1845 patients who underwent FNAB from 1997 to 2001. Non-diagnostic results of the first FNAB were divided into four groups: insufficient number of cells, inflammatory cells, necrotic debris and atypical cells. We analyzed final diagnosis of 531 patients who had non-diagnostic results from the first FNAB. Among them, 207 lesions were re-biopsied because of clinical and radiologic suspicion of malignancy. The diagnostic yield of repeated FNAB was analyzed and compared with the results of the first FNAB. Among 255 cases with 'inflammatory cells only' results, 120 cases were confirmed benignancy on follow-up. Twenty nine of 50 stypical cells (58%) were malignant of follow-up. One hundred one of 207 repeated FNAB resulted in the non-diagnostic reports, and 106 of 207 repeated FNAB were diagnosed as specific diagnosis. Among thirty lesions showing atypical cells on the repeated FNAB, 22 (73%) were identified as malignant neoplasms. When the specimen of FNAB shows atypical cells, the possibility of malignancy is very high. When the results of FNAB is non-diagnostic in the cases with clinical and radiological suspicion of malignancy, repeated FNAB procedures should be seriously considered and will be helpful for accurate specific diagnosis

  20. Lung malignancy: Diagnostic accuracies of bronchoalveolar lavage, bronchial brushing, and fine needle aspiration cytology

    Science.gov (United States)

    Sareen, Rateesh; Pandey, C L

    2016-01-01

    Background: Early diagnosis of lung cancer plays a pivotal role in reducing lung cancer death rate. Cytological techniques are safer, economical and provide quick results. Bronchoscopic washing, brushing and fine needle aspirations not only complement tissue biopsies in the diagnosis of lung cancer but also comparable. Objectives: (1) To find out diagnostic yields of bronchioalveolar lavage, bronchial brushings, FNAC in diagnosis of lung malignancy. (2) To compare relative accuracy of these three cytological techniques. (3) To correlate the cytologic diagnosis with clinical, bronchoscopic and CT findings. (4) Cytological and histopathological correlation of lung lesions. Methods: All the patients who came with clinical or radiological suspicion of lung malignancy in two and a half year period were included in study. Bronchoalveolar lavage was the most common type of cytological specimen (82.36%), followed by CT guided FNAC (9.45%) and bronchial brushings (8.19%). Sensitivity, specificity, positive and negative predictive value for all techniques and correlation with histopathology was done using standard formulas. Results: The most sensitive technique was CT FNAC – (87.25%) followed by brushings (77.78%) and BAL (72.69%). CT FNAC had highest diagnostic yield (90.38%), followed by brushings (86.67%) and BAL (83.67%). Specificity and positive predictive value were 100 % each of all techniques. Lowest false negatives were obtained in CT FNAC (12.5%) and highest in BAL (27.3%). Highest negative predictive value was of BAL 76.95 % followed by BB 75.59% and CT FNAC 70.59%. Conclusion: Before administering antitubercular treatment every effort should be made to rule out malignancy. CT FNAC had highest diagnostic yield among three cytological techniques. BAL is an important tool in screening central as well as in accessible lesions. It can be used at places where CT guided FNAC is not available or could not be done due to technical or financial limitations PMID:27890992

  1. Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?

    Science.gov (United States)

    Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M

    2009-01-01

    Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.

  2. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  3. Is there still a role for thyroid scintigraphy in the workup of a thyroid nodule in the era of fine needle aspiration cytology and molecular testing? [version 1; referees: 3 approved

    Directory of Open Access Journals (Sweden)

    Rodrigo Moreno-Reyes

    2016-04-01

    Full Text Available Thyroid scintigraphy is now rarely used in the work-up of a thyroid nodule except in the presence of a low TSH value. Therefore, autonomously functioning thyroid nodules (AFTNs with a normal TSH value are diagnosed only in the rare medical centers that continue to use thyroid scan systematically in the presence of a thyroid nodule. In this review, we discuss the prevalence of AFTN with a normal TSH level and the possible consequences of performing fine needle aspiration cytology (FNAC in an undiagnosed AFTN. We also discuss the risk of malignant AFTN which may be higher than previously stated.

  4. ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSING INTRA-ABDOMINAL LESIONS- A 6-YEAR RETROSPECTIVE STUDY IN A TERTIARY CARE HOSPITAL IN MANIPUR

    Directory of Open Access Journals (Sweden)

    Ratan Konjengbam

    2017-07-01

    Full Text Available BACKGROUND Fine-Needle Aspiration Cytology (FNAC is a widely used method, which is accurate and safe in a readily palpable masses. But, in those inaccessible lesions and deeper organs are safely aspirated using fine needle radiological procedure like ultrasound or computed tomography guided. The aim of the study is to assess the utility of FNAC in the diagnosis of intra-abdominal lesions and different pattern of lesions in particular to the sites. MATERIALS AND METHODS This retrospective study was done in the Department of Pathology, Regional Institute of Medical Sciences (RIMS, Imphal, between June 2010 and June 2016. The study included 128 intra-abdominal masses. Giemsa and Papanicolaou’s stains were used. The cytological diagnosis was correlated with clinical and radiological data to arrive at a final diagnosis. RESULTS Reports on FNAC smears were retrospectively analysed, which had been done in various anatomic sites- liver (70 cases, colon (19 cases, gallbladder (17 cases, mesenteric lymph nodes (12 cases, ovary (3 cases, adrenals (2 cases and 1 case each of pancreas, peritoneal wall, pelvic, suprapubic and flank masses. The mean age was 42.16 years with M:F of 1.3:1. The diagnostic yield was 85.2% in combination for Ultrasound Guided (USG and Computed Tomography (CT guided aspiration. The smears were classified as benign neoplastic, malignant neoplastic, non-neoplastic, inconclusive and unsatisfactory for interpretation. There were 79 (61.7% malignant neoplastic lesion, 5 (3.9% benign neoplastic lesion, 25 (19.5% non-neoplastic lesion, one (0.7% inconclusive lesions and 18 (14.1% unsatisfactory smears. The liver and the colon were the most common sites. Adenocarcinomas and Hepatocellular Carcinoma (HCC were the most common malignant lesions comprising of 35 (44.3% and 25 (31.6% of the total malignant lesions diagnosed. CONCLUSION Intra-abdominal FNA is a simple, economical and a safe procedure with high sensitivity, specificity and

  5. Noninvasive carcinoma ex pleomorphic adenoma of the parotid gland: A difficult diagnosis on fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Theresa Scognamiglio

    2015-01-01

    Full Text Available Carcinoma ex pleomorphic adenoma (CXPA is a rare epithelial malignancy that arises from a primary or recurrent pleomorphic adenoma (PA. It may be noninvasive (NI or invasive. NI CXPA is extremely rare. Preoperative diagnosis on fine needle aspiration (FNA of CXPA may be difficult and poses a diagnostic challenge to clinicians and pathologists. Herein, we describe the FNA findings of a case of NI-CXPA. A 69-year-old woman presented with rapid enlargement of a stable parotid mass of 25 years. Cytologically, malignant cells were focally associated with metachromatic fibromyxoid matrix that was homogeneous and dense with a vague fibrillary quality. There were cell groups, papillary-like clusters and single malignant cells. The nuclei were pleomorphic with irregularly dispersed chromatin, and the cytoplasm was ill-defined and granular. Nucleoli were small to inconspicuous. Mitoses and necrosis were not seen. Cytological features were not specific for any type of salivary gland carcinoma. The FNA diagnosis was primary high-grade adenocarcinoma of the parotid gland, not otherwise specified. Facial nerve-sparing total parotidectomy was performed, which histologically showed PA interspersed with ducts and nests composed of pleomorphic atypical nuclei surrounded by extensive hyalinization. Single cells were also noted. No capsular infiltration was seen in the entirely sampled tumor. Immunohistochemistry for Ki-67 showed a higher proliferation rate in the malignant ducts and p63 positive cells focally surrounded some of the malignant ducts. Histological diagnosis was NI-CXPA. Accurate diagnosis is important for proper surgical management; however, the preoperative diagnosis of NI-CXPA is difficult to make on FNA.

  6. Noninvasive carcinoma ex pleomorphic adenoma of the parotid gland: A difficult diagnosis on fine needle aspiration

    Science.gov (United States)

    Scognamiglio, Theresa; Joshi, Rohan; Kuhel, William I.; Tabbara, Sana O.; Rezaei, M. Katayoon; Hoda, Rana S.

    2015-01-01

    Carcinoma ex pleomorphic adenoma (CXPA) is a rare epithelial malignancy that arises from a primary or recurrent pleomorphic adenoma (PA). It may be noninvasive (NI) or invasive. NI CXPA is extremely rare. Preoperative diagnosis on fine needle aspiration (FNA) of CXPA may be difficult and poses a diagnostic challenge to clinicians and pathologists. Herein, we describe the FNA findings of a case of NI-CXPA. A 69-year-old woman presented with rapid enlargement of a stable parotid mass of 25 years. Cytologically, malignant cells were focally associated with metachromatic fibromyxoid matrix that was homogeneous and dense with a vague fibrillary quality. There were cell groups, papillary-like clusters and single malignant cells. The nuclei were pleomorphic with irregularly dispersed chromatin, and the cytoplasm was ill-defined and granular. Nucleoli were small to inconspicuous. Mitoses and necrosis were not seen. Cytological features were not specific for any type of salivary gland carcinoma. The FNA diagnosis was primary high-grade adenocarcinoma of the parotid gland, not otherwise specified. Facial nerve-sparing total parotidectomy was performed, which histologically showed PA interspersed with ducts and nests composed of pleomorphic atypical nuclei surrounded by extensive hyalinization. Single cells were also noted. No capsular infiltration was seen in the entirely sampled tumor. Immunohistochemistry for Ki-67 showed a higher proliferation rate in the malignant ducts and p63 positive cells focally surrounded some of the malignant ducts. Histological diagnosis was NI-CXPA. Accurate diagnosis is important for proper surgical management; however, the preoperative diagnosis of NI-CXPA is difficult to make on FNA. PMID:25972908

  7. Subacute granulomatous (De Quervain′s thyroiditis: Fine-needle aspiration cytology and ultrasonographic characteristics of 21 cases

    Directory of Open Access Journals (Sweden)

    Çigdem Vural

    2015-01-01

    Full Text Available Background: Subacute granulomatous thyroiditis (SGT is an inflammatory disease that presents with different clinical and cytological characteristics. Although the diagnosis is generally made clinically, imaging methods and fine-needle aspiration (FNA may provide assistance, particularly in atypical cases. The objective of this study is to reveal the ultrasonographic (USG and cytological characteristics of SGT. Materials and Methods: The clinical, USG and cytological findings of 21 cases diagnosed with SGT were reviewed. Results: Ultrasonographic data was available in 20 cases. A hypoechoic thyroid nodule with irregular margins was detected in 12 of the 20 total cases. Of these, 9 cases complained about pain in the thyroid lodge and generally had unilateral lesions, heterogeneous and hypoechoic areas with indistinct margins, rather than nodular lesions, which were seen in 7 cases. Cytologically, the multinuclear giant cells (MNGCs found in all cases were accompanied by a dirty background containing varying numbers of granulomatous structures, including isolated epithelioid histiocytes, proliferated/regenerated follicle epithelium cells and inflammatory cells and colloid. Conclusion: Though hypoechoic and heterogeneous areas with irregular margins are strongly associated with thyroiditis, SGT may also appear as painful or painless hypoechoic, solid nodules and generate challenges in differential diagnosis. Although the most remarkable characteristic observed in FNA cytology was the presence of multiple MNGCs with cytoplasm, a dirty background accompanied by mild-moderate cellularity, degenerated-proliferated follicular epithelium cells, rare epithelioid granulomas and mixed type inflammatory cells are characteristic for SGT. The assessment of these radiological and cytological findings in conjunction with clinical findings will assist in the achievement of an accurate diagnosis.

  8. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    Science.gov (United States)

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  9. Ultrasonographic criteria for fine needle aspiration of nonpalpable thyroid nodules 1–2 cm in diameter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang, E-mail: j0kim040@louisville.edu [Department of Radiology, University of Louisville, 530 South Jackson Street, Louisville, KY 40242 (United States); Department of Healthcare System Gangnam Center, Department of Radiology, Seoul National University Hospital, 737 Star tower, 40 floor, Yeoksam-dong, Gangnam-gu, Seoul 135-080 (Korea, Republic of); Kim, Soo Young; Yang, Ki Ra [Department of Healthcare System Gangnam Center, Department of Radiology, Seoul National University Hospital, 737 Star tower, 40 floor, Yeoksam-dong, Gangnam-gu, Seoul 135-080 (Korea, Republic of)

    2013-02-15

    Purpose: To investigate the ultrasonographic (US) characteristics for nonpalpable thyroid nodules 1–2 cm in diameter and to evaluate the guideline for fine needle aspiration (FNA) in terms of US findings. Materials and methods: Between June 2005 and November 2006, FNA was performed in 919 thyroid nodules by radiologists. Of these nodules, 51 malignant nodules and 72 benign nodules were finally included. All 123 nodules were analyzed by 3 radiologists if there were the following US characteristics: marked hypoechogenecity, hypoechogenecity, isoechogenecity, hyperechogenecity, microcalcification, coarse calcification, rim calcification, spiculated margin, taller-than-wide shape, irregular shape, hypoechoic rim and honeycomb appearance. The maximum diameters of nodules and thickness of hypoechoic rim were measured. US characteristics relevant as predictors were identified using a Chi-square or Fisher's exact test and odds ratio. We compared the diagnostic efficacy of 3 US criteria for FNA indication. Results: Microcalcification, taller-than-wide shape, marked hypoechogenecity, hypoechogenecity, coarse calcification, irregular shape and spiculated margin were significant characteristics of malignant nodules. Isoechogenecity, hypoechoic rim and honeycomb appearance was significant characteristics of benign nodules. Rim or arc calcification, hyperechogenecity and thickness of hypoechoic rim were insignificant. Among 3 US criteria for FNA indication, NFI showed the highest diagnostic efficacy, 98.0% in sensitivity, 75.0% in specificity and 150.0 in odds ratio. Conclusion: As for nonpalpable thyroid nodules 1–2 cm in diameter, US characteristics are useful for differentiating between malignant and benign nodules. Malignant US characteristics and honeycombing appearance have significant value in selecting nodules for biopsy and reducing the frequency of the FNA procedure.

  10. Diagnosis and typing of systemic amyloidosis: The role of abdominal fat pad fine needle aspiration biopsy.

    Science.gov (United States)

    Halloush, Ruba A; Lavrovskaya, Elena; Mody, Dina R; Lager, Donna; Truong, Luan

    2010-01-15

    Systemic amyloidosis (SA) has a broad nonspecific clinical presentation. Its diagnosis depends on identifying amyloid in tissues. Abdominal fat pad fine needle aspiration (FPFNA) has been suggested as a sensitive and specific test for diagnosing SA. Thirty-nine FPFNA from 38 patients (16 women and 20 men, age range 40-88 years) during a 15-year period were reviewed. Smears and cell blocks were stained with Congo red (CR). A panel of antibodies (serum amyloid protein, serum amyloid A, albumin, transthyretin, kappa light chain and lambda light chain) was used on six cell blocks from five patients. The FNA findings were correlated with clinical and histological follow-up. FPFNAs were positive, confirmed by CR in 5/39 (13%), suspicious in 1/39 (3%), negative in 28/39 (72%), and insufficient for diagnosis in 5/39 (13%) of cases. In all the positive cases, SA was confirmed within 2-16 weeks. Among the 28 negative cases, SA was diagnosed in 21, the rest were lost to follow-up. Among the insufficient cases, SA was diagnosed in four and one was lost to follow-up. Specificity was 100%, whereas sensitivity was 19%. SA typing using cell block sections was successful in three, un-interpretable in one, and negative in two cases. FPFNA for SA is not as good as previously reported. This may be due to different practice setting, level of experience, diagnostic technique, or absence of abdominal soft tissue involvement. A negative result of FPFNA does not exclude SA. Immune phenotyping of amyloid is possible on cell block.

  11. Cost-effectiveness analysis of repeat fine-needle aspiration for thyroid biopsies read as atypia of undetermined significance.

    Science.gov (United States)

    Heller, Michael; Zanocco, Kyle; Zydowicz, Sara; Elaraj, Dina; Nayar, Ritu; Sturgeon, Cord

    2012-09-01

    The 2007 National Cancer Institute (NCI) conference on Thyroid Fine-Needle Aspiration (FNA) introduced the category atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS). Repeat FNA in 3 to 6 months was recommended for low-risk patients. Compliance with these recommendations has been suboptimal. We hypothesized that repeat FNA would be more effective than diagnostic lobectomy, with decreased costs and improved rates of cancer detection. Cost-effectiveness analysis was performed in which we compared diagnostic lobectomy with repeat FNA. A Markov model was developed. Outcomes and probabilities were identified from literature review. Third-party payer costs were estimated in 2010 US dollars. Outcomes were weighted by use of the quality-of-life utility factors, yielding quality-adjusted life years (QALYs). Monte Carlo simulation and sensitivity analysis were used to examine the uncertainty of probability, cost, and utility estimates. The diagnostic lobectomy strategy cost $8,057 and produced 23.99 QALYs. Repeat FNA cost $2,462 and produced 24.05 QALYs. Repeat FNA was dominant until the cost of FNA increased to $6,091. Dominance of the repeat FNA strategy was not sensitive to the cost of operation or the complication rate. The NCI recommendations for repeat FNA regarding follow-up of AUS/FLUS results are cost-effective. Improving compliance with these guidelines should lead to less overall costs, greater quality of life, and fewer unnecessary operations. Copyright © 2012 Mosby, Inc. All rights reserved.

  12. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  13. Core needle biopsy of the thyroid: 2016 consensus statement and recommendations from Korea society of thyroid radiology

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu [Dept. of Radiology, Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of); Baek, Jung Hwan; Lee, Jeong Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); and others

    2017-01-15

    Core needle biopsy (CNB) has been suggested as a complementary diagnostic method to fine-needle aspiration in patients with thyroid nodules. Many recent CNB studies have suggested a more advanced role for CNB, but there are still no guidelines on its use. Therefore, the Task Force Committee of the Korean Society of Thyroid Radiology has developed the present consensus statement and recommendations for the role of CNB in the diagnosis of thyroid nodules. These recommendations are based on evidence from the current literature and expert consensus.

  14. [Discussion on needling sensation, arrival of qi and needling response (Deqi)].

    Science.gov (United States)

    Zhang, Fang; Wang, Hong-Du

    2012-12-01

    The current appointed teaching material of Science of Acupuncture and Moxibustion holds that there is no difference among the needling sensation, arrival of qi and needling response. However, the author has a different understanding. Therefore, Neijing (Internal Classic), its annotation, exposition and understandings of ancient and modern famous experts are cited to analyze their meanings. And the result indicates that the needling sensation is subjective feelings and perceived responses of doctors and patients. Arrival of qi is the healing process of the organ through activating the anti-pathogenic qi to expel the pathogens. The needling response is the final aim of acupuncture therapy. Thus, the meaning of needling sensation, arrival of qi, and needling response are different. And an accurate understanding can better guide acupuncture treatment.

  15. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  16. Role of endoscopic ultrasound-guided fine-needle aspiration in adrenal lesions: analysis of 32 patients

    Directory of Open Access Journals (Sweden)

    Rakesh K Gupta

    2018-01-01

    Full Text Available Objective: Endoscopic ultrasound-guided fine-needle aspiration cytology (EUS-FNAC is a precise and safe technique that provides both radiological and pathological diagnosis with a better diagnostic yield and minimal adverse events. EUS-FNAC led to the remarkable increase in the detection rate of incidentaloma found during radiologic staging or follow-up in various malignancy or unrelated conditions. Aims: We did this preliminary study with an aim to evaluate the role of EUS-FNA in diagnosing and classifying adrenal lesions, clinical impact, and compare the outcome with the previously published literature. Materials and Methods: We included 32 consecutive cases (both retrospective and prospective of EUS-guided adrenal aspirate performed over a period of 3.3 years. The indications for the aspirate in decreasing order were metastasis (most common carcinoma gall bladder > primary adrenal mass > disseminated tuberculosis > pyrexia of unknown origin. On EUS, 28 cases revealed space occupying lesion or mass (two cases bilateral and four cases revealed diffuse enlargement (two cases bilateral with a mean size of 21 mm. Results: The cytology reports were benign adrenal aspirate (43.8%, metastatic adenocarcinoma (15.6%, histoplasmosis (9.4%, tuberculosis (9.4%, round cell tumor (6.2%, adrenocortical carcinoma (3.1%, and descriptive (3.1%. Three cases (9.4% yielded inadequate sample. The TNM staging was altered in 22.23% of the cases by result of adrenal aspirate. Conclusions: EUS-FNA of the adrenal gland is a safe, quick, and sensitive and real-time diagnostic technique, which requires an integrated approach of clinician, endoscopist, and cytopathologist for high precision in diagnosis. Although the role of EUS-FNA for right adrenal is not much described, we found adequate sample yield in all the four patients that underwent the procedure.

  17. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    Science.gov (United States)

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  18. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  19. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  20. Relations between Scots pine needle element concentrations and decreased needle longevity along pollution gradients

    International Nuclear Information System (INIS)

    Lamppu, Jukka; Huttunen, Satu

    2003-01-01

    Deceased needle longevity was related to increased heavy metal concentrations. - Scots pine (Pinus sylvestris L.) shoots were sampled along transects near one urban pollution source and two smelters. Needle Mg, P and K concentrations decreased from the second to the fourth age class linearly with needle survival along the urban pollution gradient. Still, over 80% of the average concentration of these nutrients remained in the fourth needle age class. Decreased needle longevity was closely related to the increased heavy metal concentrations near the smelters. Near the urban pollution source, it was related to the increased annual needle mass and the increased needle nutrient concentrations. Decreased Mn accumulation along with needle age was detected near all pollution sources. Leaching of Mn from needles and especially from soil as a cause of decreased needle concentrations is discussed

  1. Diagnostic Accuracy and Pitfalls of Preoperative Fine Needle Aspiration Cytology in Salivary Gland Lesions

    International Nuclear Information System (INIS)

    TAHOUN, N.; EZZAT, N.

    2008-01-01

    Purpose: Evaluation of diagnostic accuracy of preoperative fine needle aspiration cytology (FNAC) in salivary gland lesions. Patients and Methods: This is a retrospective study of 82 patients presented at NCI, Cairo University with salivary gland lesion who underwent preoperative FNAC diagnosis with subsequent excision and histopathologic assessment. Cytology results were classified as negative, positive, suspicious for cancer and inadequate. The definitive histopathologic report according to WHO Histological typing was the gold standard diagnosis against which FNAC was compared. Results: Our study included 82 patients who underwent preoperative FNAC of major salivary glands with subsequent surgical excision. Male to female ratio was 1.4: 1. The median age was 42 years. Parotid gland was involved in (68.3%), submandibular in (28%) and sub mental gland in (3.7%). Forty cases (48.8%) were cytologically diagnosed as benign lesions, 26 (31.7%) were malignant and 10 (12.2%) were suspicious. Cytological findings were non diagnostic in 6 (7.3%). The most common benign cytologic diagnosis was pleomorphic adenoma; 16 out of 40 cases (40%), while the most common malignant tumor was carcinoma; 22 out of 26 cases (84.6%). Cytologic diagnoses were compared with histopathologic ones and were true-negative in 37 (92.5%), true-positive in 33 (91.6%), false-negative in 3 (8.3%) and false-positive in 3 (7.5%) cases regarding detection of malignant tumors. The cytologic diagnosis achieved a sensitivity of 91.7%; a specificity of 92.5%, PPV 91.6%, NPV 92.5% and diagnostic accuracy 92%. The rates of agreement of histopathologic type for benign and malignant tumors were 89.2% and 91%, respectively. Conclusion: The sensitivity, specificity and diagnostic accuracy of FNAC were 91.7%, 92.5% and 92%, respectively. Attention to subtle morphologic changes, pitfalls and limitations are important to increase diagnostic accuracy. Multidirectional aspiration is preferred to avoid selective

  2. Diagnosis and typing of systemic amyloidosis: The role of abdominal fat pad fine needle aspiration biopsy

    Directory of Open Access Journals (Sweden)

    Halloush Ruba

    2009-01-01

    Full Text Available Introduction: Systemic amyloidosis (SA has a broad nonspecific clinical presentation. Its diagnosis depends on identifying amyloid in tissues. Abdominal fat pad fine needle aspiration (FPFNA has been suggested as a sensitive and specific test for diagnosing SA. Materials and Methods: Thirty-nine FPFNA from 38 patients (16 women and 20 men, age range 40-88 years during a 15-year period were reviewed. Smears and cell blocks were stained with Congo red (CR. A panel of antibodies (serum amyloid protein, serum amyloid A, albumin, transthyretin, kappa light chain and lambda light chain was used on six cell blocks from five patients. The FNA findings were correlated with clinical and histological follow-up. Results: FPFNAs were positive, confirmed by CR in 5/39 (13%, suspicious in 1/39 (3%, negative in 28/39 (72%, and insufficient for diagnosis in 5/39 (13% of cases. In all the positive cases, SA was confirmed within 2-16 weeks. Among the 28 negative cases, SA was diagnosed in 21, the rest were lost to follow-up. Among the insufficient cases, SA was diagnosed in four and one was lost to follow-up. Specificity was 100%, whereas sensitivity was 19%. SA typing using cell block sections was successful in three, un-interpretable in one, and negative in two cases. Conclusion: FPFNA for SA is not as good as previously reported. This may be due to different practice setting, level of experience, diagnostic technique, or absence of abdominal soft tissue involvement. A negative result of FPFNA does not exclude SA. Immune phenotyping of amyloid is possible on cell block.

  3. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  4. Fine Needle Aspiration of Thyroid Nodules Using the Bethesda System for Reporting Thyroid Cytopathology: An Institutional Experience in a Rural Setting

    Directory of Open Access Journals (Sweden)

    Aili Guo

    2017-01-01

    Full Text Available Background. Fine needle aspiration (FNA remains the first-line diagnostic in management of thyroid nodules and reduces unnecessary surgeries. However, it is still challenging since cytological results are not always straightforward. This study aimed to examine the results of thyroid FNA using the Bethesda system for reporting thyroid cytopathology (TBSRTC to establish the level of accuracy of FNA procedures in a rural practice setting. Method. A retrospective chart review was conducted on existing thyroid FNA performed in a referral endocrine center between December 2011 and November 2015. Results. A total of 159 patients (18–88 years old and 236 nodule aspirations were performed and submitted for evaluation. 79% were benign, 3% atypia/follicular lesion of unknown significance (AUS/FLUS, 5% follicular neoplasm/suspicious for follicular neoplasm (FN/SFN, 4% suspicious for malignancy (one case was indeed an atypical parathyroid neoplasm by surgical pathology, 2% malignant, and 7% nondiagnostic. Two cases also had advanced molecular analysis on FNA specimens before thyroidectomy. Conclusion. The diagnostic yield of FNA cytology from our practice in a rural setting suggests that accuracy and specificity are comparable to results from larger centers.

  5. Transcription through the eye of a needle: daily and annual cyclic gene expression variation in Douglas-fir needles.

    Science.gov (United States)

    Cronn, Richard; Dolan, Peter C; Jogdeo, Sanjuro; Wegrzyn, Jill L; Neale, David B; St Clair, J Bradley; Denver, Dee R

    2017-07-24

    , thousands of genes reach their annual peak activity during winter dormancy. Our study establishes the fine-scale timing of daily and annual maximum gene expression for diverse needle genes in Douglas-fir, and it highlights the potential for using this information for evaluating hypotheses concerning the daily or seasonal timing of gene activity in temperate-zone conifers, and for identifying cyclic transcriptome components in other conifer species.

  6. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  7. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  8. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  9. The validity of immunocytochemical expression of cyclin D1 in fine needle aspiration cytology of breast carcinoma

    International Nuclear Information System (INIS)

    Ezzat, N.; Hafez, N.

    2012-01-01

    Purpose: The aim of this work is to study the validity of cyclin D1 expression, a cell Fenac; cycle regulatory protein, on (fine needle aspiration cytology) FNAC samples in patients with breast Breast carcinoma; carcinoma using immunostaining technique. Cyclin D1 Patient and methods: This is a study done on 70 patients with primary breast carcinoma, presented to Cytology Unit, Pathology Department, National Cancer Institute, Cairo University. They underwent preoperative FNAC and diagnosed as breast carcinoma. The cytologic and tissue section slides were subjected to cyclin D1 immunocytochemical staining. Only the nuclear immunoreactivity for cyclin D1 was considered specific. The rate of concordance, and discordance, and kappa value were calculated. Relation between cytologic expression of cyclin D1 and different clinico pathologic parameters was evaluated. Results: Cyclin D1 immunocytochemical expression was observed in 53/70 cases (75.7%) in cytologic smears. In histologic sections of the corresponding cases, cyclin D1 was detected in 48/70 cases (68.6%). The concordance rate of cyclin D1 expression in the FNA and histologic sections was 87.1% while the discordance rate was 12.9%. Kappa showed a value of 0.65. A statistically significant relation was found between cyclin D1 immunocytochemical expression and hormonal status as well as nuclear grade. Conclusion: Cyclin D1 immunocytochemical expression can be performed successfully on cytologic samples with a high concordance rate and agreement with histologic results. This can help in determining tumor biology, and plan for patients treatment. The marker showed a significant relation with hormone receptor status and nuclear grade

  10. Endoscopic ultrasound-guided fine-needle aspiration diagnosis of secondary tumors involving the pancreas: An institution′s experience

    Directory of Open Access Journals (Sweden)

    Ahmed K Alomari

    2016-01-01

    Full Text Available Background: Pancreatic masses may seldom represent a metastasis or secondary involvement by lymphoproliferative disorders. Recognition of this uncommon occurrence may help render an accurate diagnosis and avoid diagnostic pitfalls during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA. In this study, we review our experience in diagnosing secondary tumors involving the pancreas. Materials and Methods: The electronic database of cytopathology archives was searched for cases of secondary tumors involving the pancreas at our institution and a total of 31 cases were identified. The corresponding clinical presentations, imaging study findings, cytological diagnoses, the results of ancillary studies, and surgical follow-up, if available, were reviewed. Results: Nineteen of the patients were male and 12 female, with a mean age of 66 years. Twenty-three patients (74% had a prior history of malignancy, with the latency ranging from 6 months to 19 years. The secondary tumors involving the pancreas included metastatic carcinoma (24 cases, metastatic sarcoma (3 cases, diffuse large B-cell lymphoma (2 cases, and plasma cell neoplasm (2 cases. The most common metastatic tumors were renal cell carcinoma (8 cases and lung carcinoma (7 cases. Correct diagnoses were rendered in 29 cases (94%. The remaining two cases were misclassified as primary pancreatic carcinoma. In both cases, the patients had no known history of malignancy, and no ancillary studies were performed. Conclusions: Secondary tumors involving the pancreas can be accurately diagnosed by EUS-FNA. Recognizing uncommon cytomorphologic features, knowing prior history of malignancy, and performing ancillary studies are the keys to improve diagnostic performance and avoid diagnostic pitfalls.

  11. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  12. Ultrasound-Guided Fine Needle Aspiration Cytology in the Assessment of Cervical Metastasis in Patients Undergoing Elective Neck Dissection

    International Nuclear Information System (INIS)

    Dabirmoghaddam, Payman; Sharifkashany, Shervin; Mashali, Leila

    2014-01-01

    In head and neck cancer patients, diagnosis of metastatic cervical adenopathy is essential for treatment planning and prognosis assessment. Treatment of patients with head and neck cancer with clinically negative cervical lymph node (N0) remains controversial. While routine neck treatment would result in overtreatment in many patients, observation may delay the diagnosis and decrease the patients’ survival. To gain insights into the unclear questions regarding the value of diagnostic modalities in patients with N0 neck, this study was designed to compare the diagnostic efficacy of palpation, ultrasonography (US) and ultrasound-guided fine needle aspiration (USGFNA) in detecting cervical lymph node metastasis. Forty-two patients with head and neck cancer who underwent US and USGFNA prior to elective neck dissection were studied. Histopathologic findings of the neck specimens were compared with each diagnostic technique. Of the 53 neck dissection specimens, histopathology showed metastases in 16 cases. The overall accuracy of USGFNA, US and palpation was 96%, 68% and 70%, respectively. The specificity of USGFNA was superior to palpation and US alone. USGFNA had the highest sensitivity, predictive value and accuracy in detecting cervical metastases compared with other performed tests. In our study, USGFNA was superior to palpation and US in detecting metastasis in clinically negative necks. This method can be recommended as a diagnostic tool in preoperative assessment of patients without palpable metastasis, but further investigations are needed before this modality could be considered as an alternative to elective neck dissection

  13. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  14. The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer

    Directory of Open Access Journals (Sweden)

    Torill Sauer

    2014-01-01

    Full Text Available Background: Preoperative ultrasound (US and eventually US-guided fine-needle aspiration cytology (FNAC of suspicious axillary lymph nodes (ALN is a standard procedure in the work-up of suspicious breast lesions. Preoperative US FNAC may prevent sentinel node biopsy (SNB procedure in 24-30% of patients with early stage breast carcinoma. The aim of this study was to evaluate the institutional results of this preoperative diagnostic procedure. Materials and Methods: A total of 182 cases of preoperative FNAC of suspicious ALN where retrieved from the pathology files. The results were compared with the final histology and staging. False negative (FN FNAC cases were reviewed and possibly missed metastatic cases (2 were immunostained with the epithelial marker AE1/AE3. Results: There were no false positives, whereas 16 cases were FN. In all but one case the FN′s represented sampling error. Half of the 16 FN cases in this series were macrometastases. Discussion: About 83% of the preoperatively aspirated cases were N+, indicating that a radiologically suspicious ALN has a very high risk of being metastatic. Preoperative US guided FNAC from radiologically suspicious ALN is highly efficient in detecting metastases. Depending on national guidelines, a preoperative, positive ALN FNAC might help to stratify the patients as to SNB and/or ALN dissection.

  15. Discrepancy of target sites between clinician and cytopathological reports in head neck fine needle aspiration: Did I miss the target or did the clinician mistake the organ site?

    International Nuclear Information System (INIS)

    Khanlari, Mahsa; Daneshbod, Yahya; Shaterzadeh Yazdi, Hanieh; Shirian, Sadegh; Negahban, Shahrzad; Aledavood, Azita; Oryan, Ahmad; Khademi, Bijan; Daneshbod, Khosrow; Field, Andrew

    2015-01-01

    The diagnostic accuracy of fine needle aspiration cytology (FNAC) of head and neck lesions is relatively high, but cytologic interpretation might be confusing if the sample is lacking typical cytologic features according to labeled site by physician. These errors may have an impact on pathology search engines, healthcare costs or even adverse outcomes. The cytology archive database of multiple institutions in southern Iran and Australia covering the period 2001–2011, were searched using keywords: salivary gland, head, neck, FNAC, and cytology. All the extracted reports were reviewed. The reports which showed discordance between the clinician's impression of the organ involved and subsequent fine needle biopsy request, and the eventual cytological diagnosis were selected. The cytological diagnosis was confirmed by histology or cell block, with assistance from imaging, clinical outcome, physical examination, molecular studies, or microbiological culture. The total number of 10,200 head and neck superficial FNAC were included in the study, from which 48 cases showed discordance between the clinicians request and the actual site of pathology. Apart from the histopathology, the imaging, clinical history, physical examination, immunohistochemical study, microbiologic culture and molecular testing helped to finalize the target organ of pathology in 23, 6, 7, 8, 2, and 1 cases respectively. The commonest discrepancies were for FNAC of “salivary gland” [total: 20 with actual final pathology in: bone (7), soft tissue (5), lymph node (3), odontogenic (3) and skin (2)], “lymph node” [total: 12 with final pathology in: soft tissue (3), skin (3), bone (1) and brain (1)], “soft tissue” [total: 11 with final pathology in: bone (5), skin (2), salivary gland (1), and ocular region (1)] and “skin” [total: 5 with final pathology in: lymph node (2), bone (1), soft tissue (1) and salivary gland (1)]. The primary physician requesting FNAC of head and neck lesions

  16. O diagnóstico do carcinoma metastático de coróide pela biópsia aspirativa com agulha fina (BAAF: relato de caso The diagnosis of metastatic carcinoma of the choroid using fine-needle aspiration biopsy (FNAB: case report

    Directory of Open Access Journals (Sweden)

    Zélia Maria da Silva Corrêa

    2003-01-01

    male, while being treated for a solitary pulmonary condensation, reported sudden loss of vision, pain, discharge and red eye (right eye for 10 days. During the ophthalmic examination a nonregmatogenous retinal detachment as well as multiple choroidal tumors were confirmed by diagnostic ocular ultrasound. Fine-needle aspiration biopsy (FNAB was suggested to diagnose a possible metastatic disease. Fine-needle aspiration biopsy was performed under peribulbar anesthesia with sedation. A transvitreous route was chosen through a sclerotomy 4 mm from the limbus. The procedure was monitored via binocular indirect ophthalmoscopy. Two sample aspirates were obtained from different tumour foci. After fine-needle aspiration biopsy, the aspirates were sent for processing, fixation and stained with Papanicolaou and HE. RESULTS: Cytology confirmed the diagnosis of multiple metastatic tumors. Immunocytochemistry of ocular and lung aspirates revealed a common cell origin by a pankeratin (AE1/AE3 positive test. Regardless of systemic treatment with chemotherapy and improvement of the ocular status, the patient died 4 months after cytological diagnosis of metastatic carcinoma of the choroid. CONCLUSIONS: Fine-needle aspiration biopsy was efficient to diagnose and correlate ocular cytology with the primary tumor by imunohistochemical methods in this case. Fine-needle aspiration biopsy should still be used only in selected cases and further research will be necessary for it to become a standard diagnostic procedure in ophthalmology.

  17. Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection

    Science.gov (United States)

    Dickerson, Jane A.; Ramsay, Lauren M.; Dada, Oluwatosin O.; Cermak, Nathan

    2011-01-01

    Capillary isoelectric focusing and capillary zone electrophoresis are coupled with laser-induced fluorescence detection to create an ultrasensitive two-dimensional separation method for proteins. In this method, two capillaries are joined through a buffer filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second dimension separation. A fraction was transferred to the second dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125. PMID:20603830

  18. Brooke-Spiegler syndrome presenting multiple concurrent cutaneous and parotid gland neoplasms: cytologic findings on fine-needle sample and description of a novel mutation of the CYLD gene.

    Science.gov (United States)

    Malzone, Maria Gabriella; Campanile, Anna Cipolletta; Losito, Nunzia Simona; Longo, Francesco; Perri, Francesco; Caponigro, Francesco; Schiavone, Concetta; Ionna, Franco; Maiello, Francesco; Martinuzzi, Claudia; Nasti, Sabina; Botti, Gerardo; Fulciniti, Franco

    2015-08-01

    Multiple dermal cylindromas and membranous basal cell adenoma of parotid gland in a 67-year-old woman with Brooke-Spiegler syndrome (BSS) were examined by fine-needle cytology. Histology, immunochemistry, and CYLD germline mutation testing were also performed. Cytomorphology and immunochemistry of the two lesions showed basaloid neoplasms, remarkably similar, composed by proliferating epithelial cells of basal type accompanied by a smaller proportion of myoepithelial cells. CYLD gene showed a novel germline splice acceptor site mutation (c.2042-1G>C) with skipping of the entire exon 15. The occurrence of analogous tumors, dermal cylindromas, and membranous basal cell adenoma of the parotid gland, in the same patient may result from the action of a single gene on ontogenetically similar stem cells. Therefore, patients with BSS should be offered a genetic counselling for an early and correct diagnosis. © 2015 Wiley Periodicals, Inc.

  19. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site) on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Science.gov (United States)

    Loyeung, Bertrand Y. K.; Cobbin, Deirdre M.

    2013-01-01

    Introduction. In traditional Chinese acupuncture, needle sensation (deqi) is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP) on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP) maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site. PMID:24159337

  20. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Topal, U.; Berkman, Yahya M.

    2005-01-01

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ 2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  1. Incidental primary mediastinal choriocarcinoma diagnosed by endobronchial ultrasound-guided fine needle aspiration in a patient presenting with transient ischemic attack and stroke.

    Science.gov (United States)

    Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer

    2017-08-01

    We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. 3D capillary valves for versatile capillary patterning of channel walls

    NARCIS (Netherlands)

    Papadimitriou, Vasileios; van den Berg, Albert; Eijkel, Jan C.T.

    2016-01-01

    We demonstrate passive capillary patterning of channel walls with a liquid in situ. Patterning is performed using a novel 3D capillary valve system combining three standard capillary stop valves. A range of different patterns is demonstrated in three channel walls. Capillary patterning was designed

  3. Evolution of a rapid onsite evaluation (ROSE) service for endobronchial ultrasound guided (EBUS) fine needle aspiration (FNA) cytology in a UK Hospital: A 7 year audit.

    Science.gov (United States)

    Stevenson, Tracey; Powari, Manish; Bowles, Christopher

    2018-05-13

    Endobronchial ultrasound fine needle aspiration (EBUS FNA) is a well-established procedure for the diagnosis and staging of lung cancer. We review our provision of this service at the Royal Devon and Exeter NHS Foundation Trust and the role of rapid onsite evaluation (ROSE) with the increasing demand for molecular markers in this era of personalized medicine. A review of the changes in the Endoscopy clinic over the 7 years from the introduction of EBUS at the end of 2010 until 2017 was carried out. This included the availability of material obtained for diagnosis, accurate subtyping, and molecular testing. We also assessed the success of molecular genetics DNA techniques from EBUS material versus formalin fixed paraffin embedded tissue (FFPE). A total of 1218 EBUS cases with ROSE were reported between 2011 and 2017 Percentage diagnostic rates were calculated as 83, 82, 84, 92, 93, 94, and 92 for 2011, 2012, 2013, 2014, 2015, 2016, and 2017, respectively. Availability of material for immunocytochemistry ranged from 86 to 100% over the 7 years. Molecular testing was successfully performed for EGFR in 89-100% of requested cases and ALK testing in 87-100% of requested cases. EBUS sourced material gave on average twice the amount of DNA and fewer amplicon repeats per patient compared to FFPE material. ROSE at EBUS FNA provides access to suitable material for molecular testing with increased yields in the form of needle washings for EGFR with FFPE materials for ALK and PDL1 testing. © 2018 Wiley Periodicals, Inc.

  4. Validation of American Thyroid Association Ultrasound Risk Assessment of Thyroid Nodules Selected for Ultrasound Fine-Needle Aspiration.

    Science.gov (United States)

    Tang, Alice L; Falciglia, Mercedes; Yang, Huaitao; Mark, Jonathan R; Steward, David L

    2017-08-01

    The aim of this study was to validate the American Thyroid Association (ATA) sonographic risk assessment of thyroid nodules. The ATA sonographic risk assessment was prospectively applied to 206 thyroid nodules selected for ultrasound-guided fine-needle aspiration (US-FNA), and analyzed with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC), as well as surgical pathology for the subset undergoing surgical excision. The analysis included 206 thyroid nodules averaging 2.4 cm (range 1-7 cm; standard error of the mean 0.07). Using the ATA US pattern risk assessment, nodules were classified as high (4%), intermediate (31%), low (38%), and very low (26%) risk of malignancy. Nodule size was inversely correlated with sonographic risk assessment, as lower risk nodules were larger on average (p risk estimates (high 70-90%, intermediate 10-20%, low 5-10%, and very low 3%). ATA US pattern risk assessment also appropriately predicted the proportion of nodules classified as malignant or suspicious for malignancy through TBSRTC classification-high (77%), intermediate (6%), low (1%), and very low 0%-as well as benign TBSRTC classification-high (0%), intermediate (47%), low (61%), and very low (70%) (p risk stratification (high 100%, intermediate 21%, low 17%, and very low 12%; p = 0.003). This prospective study supports the new ATA sonographic pattern risk assessment for selection of thyroid nodules for US-FNA based upon TBSRTC and surgical pathology results. In the setting of indeterminate cytopathology, nodules categorized as atypia of undetermined significance/follicular lesion of undetermined significance with ATA high-risk sonographic patterns have a high likelihood of being malignant.

  5. Use of FTA cards for the storage of breast carcinoma nucleic acid on fine-needle aspiration samples.

    Science.gov (United States)

    Peluso, Anna Lucia; Cascone, Anna Maria; Lucchese, Lucrezia; Cozzolino, Immacolata; Ieni, Antonio; Mignogna, Chiara; Pepe, Stefano; Zeppa, Pio

    2015-10-01

    The preservation and storage of nucleic acids is important for DNA molecular techniques. The material obtained by fine-needle aspiration (FNA) is often scanty and can not be wasted. FTA cards are filter papers that immobilize and stabilize nucleic acids and can be stored at room temperature. The current study evaluated whether nucleic acids of breast carcinoma cells, obtained by FNA in a clinical setting, may be collected, stored, and preserved on FTA cards. Thirty breast carcinoma, 5 non-Hodgkin lymphoma (NHL), and 5 benign reactive lymph node (RLN) cell samples obtained by FNA were stored at -80 °C and on FTA cards. DNA extraction and polymerase chain reaction were performed on cells at -80 °C and on 2 punched disks of FTA cards. Fifty nanograms of extracted DNA from both sample types were used to amplify the Janus Kinase 2 (JAK2) gene. The mean value of DNA extracted from breast carcinoma cells was 28.19 ng/µL for that stored at -80 °C and 3.28 ng/µL for that stored on FTA cards. Agarose gel analysis demonstrated expected bands of DNA in 29 cases (97%) with both methods. The mean value of DNA extracted from NHL and RLN samples was 37.54 ng/µL and 4.28 ng/µL, respectively, and agarose gel analysis demonstrated bands of high molecular weight DNA in both methods. Significant differences in DNA yield were found between storage at -80 °C and FTA cards (PFTA cards can be conveniently used for the storage of breast carcinoma cells obtained by FNA, thus providing a reliable alternative to traditional methods. © 2015 American Cancer Society.

  6. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  7. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  8. Fine needle aspiration biopsy of three cases of squamous cell carcinoma presenting as a thyroid mass: cytological findings and differential diagnosis.

    Science.gov (United States)

    Rosa, M; Toronczyk, K

    2012-02-01

    Primary squamous cell carcinomas of the thyroid gland are extremely rare, comprising about 1% of thyroid malignancies. Although squamous cell carcinomas are readily identified as such on aspiration cytology in the majority of cases, the differentiation of primary versus metastatic tumour might not always be easy. Herein, we report three cases of squamous cell carcinomas involving the thyroid gland. Fine needle aspiration cytology (FNAC) was performed in three patients with a thyroid mass using standard guidelines. Smears were stained with Diff-Quik and Papanicolaou stains. Two patients were male and one was female, aged 59, 45 and 35 years, respectively. In all three patients a thyroid mass was present. FNAC smears in all cases showed cytological features of squamous cell carcinoma including keratinization and necrosis. After clinical and cytological correlation, one case appeared to be primary, one case metastatic, and in the third case no additional clinical information or biopsy follow-up was available for further characterization. Because primary squamous cell carcinoma of the thyroid is a rare finding, metastatic squamous cell carcinoma should always be excluded first. Metastatic disease usually presents in the setting of widespread malignancy, therefore a dedicated clinical and radiological investigation is necessary in these cases. In both clinical scenarios the patient's prognosis is poor. © 2010 Blackwell Publishing Ltd.

  9. Diagnose of the prostate cancer: Utility of the antigen specifies of prostate, transrectal echography and aspired by fine needle; Diagnostico del cancer de prostata: utilidad del antigeno especifico de prostata, ecografia transrectal y aspirado por aguja fina

    Energy Technology Data Exchange (ETDEWEB)

    De Nubbila, Eduardo; Rosillo, Marco; Fals, Orlando

    1993-04-01

    We describe three improved methods of detecting prostate cancer while it is still confined to the gland: Prostrate specific antigen (PSA), trans-rectal ultrasound (TRUS) and trans-rectal ultrasound-directed prostatic fine needle aspirate (TRFNA). Of a total of 60 studied cases, 23 cytological procedures were done, and half of these were found to have prostate cancer. We compare traditional methods like digital rectal examination and prostatic phosphatase acid with PSA and TRFNA. We conclude that these methods increase the sensibility and specificity of early prostate cancer detection.

  10. Comparative study on the usefulness of 99Tcm-MIBI scintigraphy, mammography, and fine-needle aspiration cytology in diagnosis of benign and malignant breast lesions

    International Nuclear Information System (INIS)

    Bai Yuekui; Cao Wenlan; Zhang Baoning; Liu Lin; Chen Shengzu; Tang Jin

    2001-01-01

    Objective: To evaluate the potential role of scintimammography (SMM) in conjunction with mammography (MG) and fine-needle aspiration cytology (FNAC) in detecting breast cancer. Methods: A total of 57 women with breast mass underwent SMM, 54 of them had MG and FNA cytology in addition to SMM. The result diagnoses were verified with histological examination. Results: Of the 3 patients who had lumpectomy, SMM showed normal. Of the 54 patients who had SMM, MG and FNAC, the number of suspected cancer in SMM, MG and FNAC was 31, 28 and 37, respectively. The sensitivity of SMM, MG and FNA cytology was 79.5%, 71.8% and 94.9%, respectively, and the accuracy was 78.9%, 72.2% and 96.3% respectively. In 57 patients, positive result was set at least by one of these techniques. Conclusions: SMM in conjunction with MG and FNA cytology is the best combination for the early detection and diagnosis of breast cancer. In women with suspected MG or abnormal FNA cytology and further investigations were required, SMM may be helpful as an additional noninvasive procedure

  11. [Hepatic fine needle aspiration biopsy. Experience in the study of hepatic masses at the Salvador Zubiran National Institute of Nutrition].

    Science.gov (United States)

    Angeles-Angeles, A; Gamboa-Domínguez, A; Velázquez Fernández, D; Muñoz-Fernández, L

    1994-01-01

    The results of 114 fine-needle aspiration biopsies (FNAB) of the liver performed during six years (1987-1992) at the Departament of Pathology of the Instituto Nacional de la Nutrición Salvador Zubirán are presented. All were done by radiologists under ultrasonographic (three cases) or computerized tomographic guidance (111 cases). In order to determine the diagnostic accuracy, diagnoses made by FNAB were compared with those made by histological examination (coarse biopsies or surgical specimens) and/or by other diagnostic procedures including the clinical follow-up. Six cases were excluded because clinical information was not available. In 92 cases (85.2%) a correct diagnosis was made, in six (5.5%) the sample was inadequate and in 10 (9.3%) the diagnosis made by FNAB was incorrect. The diagnoses made were as follows: hepatocarcinoma 44, metastatic carcinoma 27, inflammatory lesions 12, regeneration 10, normal eight, unclassified carcinoma five, and lymphoma two. The sensitivity was 96.2, specificity 93.1, positive predictive value 97.4, negative predictive value 90.0, accuracy 95.3 and prevalence 73.1. There were three false negative and two false positive for carcinoma. These figures are similar to those found by other authors. No relevant complications were observed. It is concluded that FNAB of the liver is a safe, inexpensive and reliable method in the diagnoses of liver masses.

  12. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Slope wavenumber spectrum models of capillary and capillary-gravity waves

    Institute of Scientific and Technical Information of China (English)

    贾永君; 张杰; 王岩峰

    2010-01-01

    Capillary and capillary-gravity waves possess a random character, and the slope wavenumber spectra of them can be used to represent mean distributions of wave energy with respect to spatial scale of variability. But simple and practical models of the slope wavenumber spectra have not been put forward so far. In this article, we address the accurate definition of the slope wavenumber spectra of water surface capillary and capillary-gravity waves. By combining the existing slope wavenumber models and using th...

  14. Effect of Co60 irradiation on capillary changes in the rat periosteum

    International Nuclear Information System (INIS)

    Hachiya, Hiroshi

    1992-01-01

    There exist considerable literatures on the vascular changes by tolerance dose or over tolerance dose irradiation, but little work has been done to study the effect of under tolerance dose irradiation on capillary changes. The purpose of this study was to observe capillary changes in the periosteum of rats after Co 60 irradiation. The vascularity of the periosteum was observed with vascular resin casts and scanning electron microscope at 3 days to 30 weeks after the heads were exposed to 10 Gy or 20 Gy of Co 60 γ ray. The results were as follows: In rats irradiated with 10 Gy, leakage of resin from the fine blood vessels was observed at 3 weeks. Decrease in the diameter of small blood vessels and decrease of capillary networks were observed at 5 weeks. These changes improved at 7 weeks. In rats irradiated with 20 Gy, leakage of resin and decrease in the diameter of the small blood vessels were observed at 2 weeks. The number of small blood vessels was decreased at 4 weeks. These changes improved at 7 weeks. (author) 60 refs

  15. Diagnostic Benefit of Thyroglobulin Measurement in Fine-Needle Aspiration for Diagnosing Metastatic Cervical Lymph Nodes from Papillary Thyroid Cancer: Correlations with US Features

    International Nuclear Information System (INIS)

    Jeon, Se Jeong; Kim, Eun Hee; Son, Kyu Ri; Park, Do Joon; Cho, Bo Youn; Na, Dong Gyu; Park, Jeong Seon; Baek, Jung Hwan; Kim, Yoon Suk

    2009-01-01

    Our goals were to determine the added value of fine-needle aspiration biopsy (FNAB)-thyroglobulin (Tg) measurements over FNAB-cytology alone for diagnosing metastatic nodes, and to determine whether the ultrasound features of lymph nodes can be used to identify lymph nodes that may benefit from FNAB-Tg measurement in patients with papillary thyroid cancer. We retrospectively evaluated 76 surgically proven cervical lymph nodes. Twenty-nine patients were awaiting surgery and 18 patients had undergone thyroid surgery for papillary thyroid cancer. Ultrasound-guided FNAB and Tg measurements were performed and the ultrasound features were evaluated. The accuracies, sensitivities, and specificities of FNAB-cytology, FNAB-Tg, and combined FNAB-Tg/cytology were 90%, 80%, and 100%; 92%, 95%, and 90%; and 93%, 96%, and 90%, respectively. The diagnostic sensitivity of FNAB-Tg for metastatic nodes was significantly higher than that of FNAB-cytology (p = 0.011). Furthermore, combined FNAB-Tg/cytology significantly increased sensitivity (p = 0.002) and accuracy (p = 0.03) as compared with FNAB-cytology. Combined FNAB-Tg/cytology is significantly more sensitive and accurate at detecting metastatic nodes than FNAB-cytology alone. FNAB-Tg was better at diagnosing metastases in small lymph nodes

  16. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  17. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  18. Axillary fine needle aspiration cytology for pre-operative staging of patients with screen-detected invasive breast carcinoma.

    LENUS (Irish Health Repository)

    Hayes, Brian D

    2012-02-01

    INTRODUCTION: Fine needle aspiration cytology (FNAC) of radiologically abnormal axillary lymph nodes in patients with breast cancer can identify patients suitable for primary axillary clearance (AC) rather than sentinel node biopsy, enabling surgical axillary staging by a single operation. This study assessed the accuracy of FNAC in predicting positive axillary lymph nodes. METHODS: 161 patients with screen-detected invasive carcinoma and who had pre-operative FNAC of a radiologically abnormal axillary lymph node were identified from two screening units, The axillary FNAC reports were correlated with sentinel node biopsy and AC reports, and sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated. RESULTS: FNAC had a moderate sensitivity (66.3%) and NPV (71.8%), and a high specificity (98.7%) and PPV (98.3%). Most patients (86%) had a single axillary operation. The sensitivity was highest in grade 3 (81.8%) and ductal type (77.8%) tumours. The sensitivity was lower in tumours of special type (34.8%), grade 1 tumours (50%) and those without lymphovascular invasion (LVI) (55.9%). The NPV was highest in pT1 (86.7%) and in grade 1 (84.5%) tumours, and lowest (44%) in tumours with LVI. The PPV was 100% in grade 1 and 3 tumours, stage pT2 and pT3 tumours and those without LVI, and was high (>96%) in all other groups. In lymph-node-positive patients, the mean number of lymph nodes involved was higher in the case of a positive (6.4) than negative FNAC (4.4). CONCLUSIONS: FNAC of ultrasonically abnormal axillary lymph nodes achieved surgical staging by a single operation in most patients with screen-detected invasive breast carcinoma, with moderate sensitivity and high specificity.

  19. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  20. Punção aspirativa por agulha fina para diagnóstico de mastocitoma em cães Fine needle aspiration for diagnosis of mast cell tumors in dogs

    Directory of Open Access Journals (Sweden)

    G.E. Lavalle

    2003-08-01

    Full Text Available Fine needle aspiration (FNA associated with the cytological diagnosis mast cell tumor is a widely employed technique in human medicine, but it is still underused in veterinary medicine. The aim of this study was to demonstrate the efficacy of FNA technique for the diagnosis of mast cell tumors in dogs. Over one year period all dogs referred to the Veterinary Hospital of the Universidade Federal de Minas Gerais with tumor-like formations of the skin were submitted to FNA. In order to detect metastasis, both skin lesions and the regional lymph nodes were subjected to FNA. After surgical removal of the lesions, histological examination indicated a complete agreement with the cytological diagnosis. In conclusion, FNA technique is a good choice for diagnosis of mast cell tumors in dogs. In addition, FNA allows an adequate and early therapeutic planning.

  1. [Deep needling and shallow needling at three acupoints around ear for subjective tinnitus: a randomized controlled trial].

    Science.gov (United States)

    Yin, Tao; Ni, Jinxia; Zhu, Wenzeng

    2015-10-01

    To compare the effective differences between deep needling and shallow needling at three acupoints around ear for subjective tinnitus. Fifty patients with subjective tinnitus were randomized divided into a deep needling group and a shallow needling group, 25 cases in each group. Twenty-two patients in the deep needling group and 20 patients in the shallow needling group were brought into statistic in the end. In the two groups, the three acupoints around ear and distal acupoints were both selected. The acupoints of the affected side such as Yifeng (TE 17), Tinghui (GB 2), Ermen (TE 21), Zhigou (TE 6), Zhongzhu (TE 3) and Hegu (LI 4) were adopted. Yifeng (TE 17), Tinghui (GB 2) and Ermen (TE 21) were acupunctured 30-38 mm in the deep needling group and 15-20 mm in the shallow needling group. The other acupoints were conventionally acupunctured in the two groups. The needles were retained for 30 min,once a day and five times a week for all patients. The treatment was continuously for 4 weeks in the two groups. Tinnitus handicap inventory (THI) scores, tinnitus grades and visual analogue scale (VAS) for tinnitus sound levels were observed before and after treatment, and the effects of the two groups were compared. The total effective rate in the deep needling group was 59.1% (13/22), and it was better than 20.0% (4/20) in the shallow needling group (P deep needling, group, the THI score, tinnitus grade and the VAS score were improved than those before treatment (all P shallow needling group, the three above indices before and after treatment were not different in statistical significance (all P > 0.05). After treatment, all the three indices in the deep needling group were superior to those in the shallow needling group (all P shallow needling at the three acupoints.

  2. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  3. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  4. Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings

    Science.gov (United States)

    Lee, Mi-Jung; Hong, Soon Won; Chung, Woung Youn; Kwak, Jin Young; Kim, Min Jung

    2011-01-01

    Purpose To compare the cytological results of ultrasound-guided fine-needle aspiration (US-FNA) cytology of thyroid nodules to sonographic findings and determine whether US findings are helpful in the interpretation of cytological results. Materials and Methods Among the thyroid nodules that underwent US-FNA cytology, we included the 819 nodules which had a conclusive diagnosis. Final diagnosis was based on pathology from surgery, repeated FNA cytology or follow-up of more than one year. Cytological results were divided into five groups: benign, indeterminate (follicular or Hurthle cell neoplasm), suspicious for malignancy, malignant, and inadequate. US findings were categorized as benign or suspicious. Cytological results and US categories were analyzed. Results Final diagnosis was concluded upon in 819 nodules based on pathology (n=311), repeated FNA cytology (n=204) and follow-up (n=304), of which 634 were benign and 185 were malignant. There were 560 benign nodules, 141 malignant nodules, 49 nodules with inadequate results, 21 with indeterminate results, and 48 that were suspicious for malignancy. The positive and negative predictive values of the US categories were 59.1% and 97.0%, and those of the cytological results were 93.7% and 98.9%. The US categories were significantly correlated with final diagnosis in the benign (p=0.014) and suspicious for malignancy (pcytological result groups, but not in the inadequate and indeterminate cytological results groups. The false positive and negative rates of cytological results were 1.9% and 3.2%. Conclusion Sonographic findings can be useful when used alongside cytological results, especially in nodules with cytological results that are benign or suspicious for malignancy. PMID:21786450

  5. Topical topic: value of fine needle aspiration biopsy in childhood rhabdomyosarcoma: twenty-six years of experience in Slovenia.

    Science.gov (United States)

    Pohar-Marinsek, Ziva; Anzic, Jozica; Jereb, Berta

    2002-06-01

    Chemotherapy (Cht) for rhabdomyosarcoma (RMS) given before local treatment can prevent mutilating surgery and high-dose irradiation (RT). Fine needle aspiration biopsy (FNAB) can confirm the diagnosis and neoadjuvant treatment can start without delay. The purpose of our study was to assess the role of FNAB in the management of childhood RMS in Slovenia. A total of 78 children and young adults were included. FNAB provided the pre-treatment diagnosis in 37 and surgical biopsy in 41 patients. In 61 cases recurrent/metastatic disease was aspirated. Cytological diagnoses were compared to the original histological diagnoses. All case histories, cytological and histological material were reviewed and immunocytochemical staining performed when necessary. FNAB provided a correct diagnosis of malignancy in all 37 primary tumours, a specific diagnosis of RMS was given in 29 (78%). With the use of immunocytochemistry during the last 15 years, the accuracy has risen to 87%. FNAB provided the diagnosis of recurrence/metastasis in 57/61 cases. No complications of FNAB were noted. Review of histology reclassified five original diagnoses of RMS into one malignant rhabdoid tumour and four sarcomas NOS. In review of cytology we were able to sub classify 80% of RMS. FNAB is a safe method, which enables us to establish the pre-treatment diagnosis of RMS, and to some extent even its type, without delay. In our study, FNAB successfully replaced surgical biopsy in 87% of RMS patients during the last 15 years. Neoadjuvant Cht was started immediately, surgery was delayed and more conservative. Consequently, the risk for treatment sequelae was considerably reduced. Copyright 2002 Wiley-Liss, Inc.

  6. Needle-like Co3O4 anchored on the graphene with enhanced electrochemical performance for aqueous supercapacitors.

    Science.gov (United States)

    Guan, Qun; Cheng, Jianli; Wang, Bin; Ni, Wei; Gu, Guifang; Li, Xiaodong; Huang, Ling; Yang, Guangcheng; Nie, Fude

    2014-05-28

    We synthesized the needle-like cobalt oxide/graphene composites with different mass ratios, which are composed of cobalt oxide (Co3O4 or CoO) needle homogeneously anchored on graphene nanosheets as the template, by a facile hydrothermal method. Without the graphene as the template, the cobalt precursor tends to group into urchin-like spheres formed by many fine needles. When used as electrode materials of aqueous supercapacitor, the composites of the needle-like Co3O4/graphene (the mass ratio of graphene oxide(GO) and Co(NO3)2·6H2O is 1:5) exhibit a high specific capacitance of 157.7 F g(-1) at a current density of 0.1 A g(-1) in 2 mol L(-1) KOH aqueous solution as well as good rate capability. Meanwhile, the capacitance retention keeps about 70% of the initial value after 4000 cycles at a current density of 0.2 A g(-1). The enhancement of excellent electrochemical performances may be attributed to the synergistic effect of graphene and cobalt oxide components in the unique multiscale structure of the composites.

  7. Presence in the pre-surgical fine-needle aspiration of potential thyroid biomarkers previously identified in the post-surgical one.

    Directory of Open Access Journals (Sweden)

    Federica Ciregia

    Full Text Available Fine-needle aspiration biopsy (FNA is usually applied to distinguish benign from malignant thyroid nodules. However, cytological analysis cannot always allow a proper diagnosis. We believe that the improvement of the diagnostic capability of pre-surgical FNA could avoid unnecessary thyroidectomy. In a previous study, we performed a proteome analysis to examine FNA collected after thyroidectomy. With the present study, we examined the applicability of these results on pre-surgical FNA. We collected pre-surgical FNA from 411 consecutive patients, and to obtain a correct comparison with our previous results, we processed only benign (n=114, papillary classical variant (cPTC (n=34 and papillary tall cell variant (TcPTC (n=14 FNA. We evaluated levels of five proteins previously found up-regulated in thyroid cancer with respect to benign nodules. ELISA and western blot (WB analysis were used to assay levels of L-lactate dehydrogenase B chain (LDHB, Ferritin heavy chain, Ferritin light chain, Annexin A1 (ANXA1, and Moesin in FNA. ELISA assays and WB analysis confirmed the increase of LDHB, Moesin, and ANXA1 in pre-surgical FNA of thyroid papillary cancer. Sensitivity and specificity of ANXA1 were respectively 87 and 94% for cPTC, 85 and 100% for TcPTC. In conclusion, a proteomic analysis of FNA from patients with thyroid nodules may help to distinguish benign versus malignant thyroid nodules. Moreover, ANXA1 appears to be an ideal candidate given the high sensitivity and specificity obtained from ROC curve analysis.

  8. The yield of adequate and conclusive fine-needle aspiration results in thyroid nodules is uniform across functional and goiter types.

    Science.gov (United States)

    Liel, Y

    1999-01-01

    Relatively little is known about the cytological characteristics of hyperfunctioning (hot) thyroid nodules. Concern has been expressed that fine-needle aspiration (FNA) identifies hot nodules as follicular tumors or indeterminate, and as a consequence patients could be unnecessarily referred for surgery. Between 1979 and 1996, thyroid FNA was performed on 829 patients. Result of thyroid scan was available in 326; 69 (21%) patients had hot, and 257 (79%) had warm or cold thyroid nodules. Nodules in each of these major groups were divided into 2 subgroups: clinically solitary nodules and dominant nodules in multinodular goiters (MNG). The frequencies of adequate versus inadequate FNA samples, and of conclusive versus indeterminate FNA results were determined separately for each of the groups and subgroups. In addition, patients with hot nodules and overt hyperthyroidism were identified and evaluated separately. Bivariate analyses were performed for the frequency of adequate versus inadequate smears and conclusive versus indeterminate results between hot, toxic, and cold-warm nodules, and between solitary nodules and MNG. The frequency of adequate aspirations and conclusive results in the various groups and subgroups was found to be statistically indistinguishable. In conclusion, the yield of adequate samples and the rate of conclusive results of FNA in thyroid nodules is similar, irrespective of the functional state or of goiter presentation. Hot thyroid nodules do not seem to produce an increase in the rate of inadequate or indeterminate FNA results, and therefore, do not affect the overall performance of thyroid FNA.

  9. Gas-Filled Capillary Model

    International Nuclear Information System (INIS)

    Steinhauer, L. C.; Kimura, W. D.

    2006-01-01

    We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration -- Laser Wakefield (STELLA-LW) experiment

  10. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    Science.gov (United States)

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  11. Multiple capillary biochemical analyzer

    Science.gov (United States)

    Dovichi, N.J.; Zhang, J.Z.

    1995-08-08

    A multiple capillary analyzer allows detection of light from multiple capillaries with a reduced number of interfaces through which light must pass in detecting light emitted from a sample being analyzed, using a modified sheath flow cuvette. A linear or rectangular array of capillaries is introduced into a rectangular flow chamber. Sheath fluid draws individual sample streams through the cuvette. The capillaries are closely and evenly spaced and held by a transparent retainer in a fixed position in relation to an optical detection system. Collimated sample excitation radiation is applied simultaneously across the ends of the capillaries in the retainer. Light emitted from the excited sample is detected by the optical detection system. The retainer is provided by a transparent chamber having inward slanting end walls. The capillaries are wedged into the chamber. One sideways dimension of the chamber is equal to the diameter of the capillaries and one end to end dimension varies from, at the top of the chamber, slightly greater than the sum of the diameters of the capillaries to, at the bottom of the chamber, slightly smaller than the sum of the diameters of the capillaries. The optical system utilizes optic fibers to deliver light to individual photodetectors, one for each capillary tube. A filter or wavelength division demultiplexer may be used for isolating fluorescence at particular bands. 21 figs.

  12. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  13. Capillaries for use in a multiplexed capillary electrophoresis system

    Science.gov (United States)

    Yeung, E.S.; Chang, H.T.; Fung, E.N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  14. Agglomeration of coal fines for premium fuel application

    International Nuclear Information System (INIS)

    Atalay, A.; Zaman, M.D.

    1992-01-01

    This paper reports on fine coal in liquid suspension, which can be agglomerated in a number of ways. One of the oldest procedures involves the addition of electrolyte to the suspension to cause a reduction in the zeta potential and allow colliding particles to agglomerate. A second method involves the use of polymeric flocculants to bridge between particles. Both of these technologies are being used in the wastewater treatment plants for removal of fine waste particles from contaminated water. A third method involves the addition of a second immiscible liquid preferentially to wet the particles and cause adhesion by capillary interfacial forces. While the bonding forces in the first two methods are small and result in rather weak and voluminous agglomerates, the third method is postulated to produce more dense and much stronger agglomerates. In the case of fine coals, the carbonaceous constituents can be agglomerated and recovered from the aqueous suspension with many different coagulants. Inorganic or ash-forming constituents are also agglomerated along with the fine coal particles. As the froth floatation, agglomeration using coal and colloidal dust to effect a separation. Froth floatation, however, becomes less effective where extremely fine particles of cal must be treated or if there is considerable clay-size particle present. In contrast, there appears to be virtually no lower limit on the particle size suitable for agglomeration uses

  15. Ultrasound screening of thyroid nodules in adults with no previous exposed to irradiation comparison between scanning, palpation and fine needle aspiration cytology. A study in Ghaem Hospital, Mashhad, North East of Iran

    International Nuclear Information System (INIS)

    Rahrouh, M.; Namadanian, G.R.; Zakavi, S.R.; Rezaei, H.

    2003-01-01

    There are a great number of studies on the association between childhood radiation exposure and thyroid nodules and cancer. Ultrasound imaging of thyroid nodules is valuable part of diagnostics and identifies abnormalities, because ultrasound can detect nodules as small as 2-3 mm and no radiation is involved , it has gained wide acceptance for the screening of nodular thyroid disease. 500 subjects were selected randomly from medical students in university of medical sciences in Mashhad North East of Iran. Individuals were screened by a health survey , thyroid ultrasounds, 99mTc-pertechnetate scans, palpation and fine needle aspiration obtained as necessary. The ultrasound was performed with a 7.5-MHz transducer in direct contact with the lubricated skin of the extended neck. Each ultrasound exam was read independently by two radiologists and one endocrinologist. Each nodule was characterized as follows: 1) presence; 2) size ; 3) location; ant or post; 4) location; upper pole, midportion of lobe, lower pole, or isthmus; and 5) type; solid, cystic, or mixed. In 500 cases (312 men, 188 women; age range, 18 - 30 years) underwent neck sonography. Normal findings were verified by clinical follow-up and thyroid disease was found in (5%) of subjectes. A total of 25 certain thyroid nodules were detected by the ultrasound examinations. Eighty eight percent nodules were less than 1.0 cm dimension.Among the subjects who had them thyroid nodules,(48%) were cystic , (44%) were hypoechoic lesions and (8 %) were hyperechoic .The abnormality of thyroid echo was solitary in (1,8%) ,multiple in (1,4%) and diffuse in (0,6%) of subjectes. All abnormal findings were verified by fine needle aspiration biopsy and correlated with thyroid scan, and surgery. The results reported here can be compared to several reports on the prevalence of ultrasound detected thyroid nodules in adult populations not exposed to radiation .The major advantage is that ultrasound can find clinically important

  16. Metastasis of colon cancer to the thyroid gland: a case diagnosed on fine-needle aspirate by a combined cytological, immunocytochemical, and molecular approach.

    Science.gov (United States)

    Cozzolino, Immacolata; Malapelle, Umberto; Carlomagno, Chiara; Palombini, Lucio; Troncone, Giancarlo

    2010-12-01

    Fine-needle aspiration (FNA) with cytological evaluation reliably diagnoses primary and secondary thyroid neoplasms. However, identifying the primary origin of a metastatic process involving the thyroid gland is challenging. In particular, metastasis of colon cancer to the thyroid gland is very rare. In this case report, a right lobe solid thyroid nodule in a 66-year-old male was aspirated. FNA cytology showed necrosis and atypical tall columnar cells; since, the patient at age 60 had undergone surgery for a sigmoid-rectal cancer metastasizing to the liver and subsequently to the lung, a suspicion of metastasis from colon cancer was raised. This was corroborated by cell-block immunocytochemistry showing a cytokeratin (CK) 7 negative/CK20-positive staining pattern; thyreoglobulin and TTF-1 were both negative. Since KRAS codon 12/13 mutations frequently occur in colon cancer, whereas they are extremely uncommon in primary thyroid tumors, DNA was extracted from the aspirated cells, and KRAS mutational analysis was carried out. The codon 12 G12D mutation was found; the same mutation was evident in the primary cancer of the colon and in its liver and lung metastasis. Thus, a combined cytological, immunocytochemical and molecular approach unquestionably correlated metastatic adenocarcinoma cells aspirated from the thyroid to a colo-rectal origin. © 2010 Wiley-Liss, Inc.

  17. Imaging alveolar-capillary permeability in experimental respiratory distress syndrome

    International Nuclear Information System (INIS)

    Suzuki, T.; Watanabe, S.; Wagner, H.N.; Swift, D.L.; Proctor, D.F.

    1982-01-01

    Pulmonary edema can be induced in dogs by low doses of oleic acid (20 μl/kg) given intravenously, simulating the adult respiratory distress syndrome (ARDS). Alveolar-capillary permeability was measured in dogs, using sup(99m)Tc-DTPA and sup(99m)Tc-albumin fine aerosols produced by a newly designed separator. This separator eliminates the effect of mucociliary movement on aerosol clearance. The small molecular-laden aerosol particles were cleared in the order: sup(99m)-TcO 4 - , sup(99m)Tc-DTPA, and sup(99m)Tc-disofenin; the Tsub(1/2) of lung clearance correlated with molecular sizes. Experimental ARDS increased the lung clearance of sup(99m)Tc-DTPA. Lung clearance of large molecule (sup(99m)Tc-albumin) laden aerosol particles was not accelerated in the ARDS model. Inhalation with fine aerosols revealed increased alveolar permeability in the ARDS model without any change of cardiac output

  18. Capillary detectors

    International Nuclear Information System (INIS)

    Konijn, J.; Winter, K.; Vilain, P.; Wilquet, G.; Fabre, J.P.; Kozarenko, E.; Kreslo, I.; Goldberg, J.; Hoepfner, K.; Bay, A.; Currat, C.; Koppenburg, P.; Frekers, D.; Wolff, T.; Buontempo, S.; Ereditato, A.; Frenkel, A.; Liberti, B.; Martellotti, G.; Penso, G.; Ekimov, A.; Golovkin, S.; Govorun, V.; Medvedkov, A.; Vasil'chenko, V.

    1998-01-01

    The option for a microvertex detector using glass capillary arrays filled with liquid scintillator is presented. The status of capillary layers development and possible read-out techniques for high rate environment are reported. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  19. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  20. Comparison of diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration cytology and cell block in solid lesions

    Directory of Open Access Journals (Sweden)

    Avinash Bhat Balekuduru

    2017-01-01

    Full Text Available Background and Aim: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA is a procedure of choice for the diagnostic evaluation of submucosal and periluminal lesions. Tissue sample can be obtained by EUS-FNA cytology (FNAC or cell block (CB. The aim of the present study is to compare diagnostic yield of EUS-FNA CB and cytology in the absence of onsite pathologist following a protocol-based EUS-FNA approach in solid lesions. Patients and Methods: Participants who underwent EUS-FNA at our center for solid submucosal or periluminal lesions (pancreas, lymph node, and liver between 2014 and 2016 were included, retrospectively. The indication for the procedure along with the clinical and other investigation details and the final etiological diagnosis were recorded on uniform structured data forms. The diagnostic yield of cytology and CB were compared using McNemar's test. The P < 0.05 was considered statistically significant. Results: EUS-FNA for solid lesion was performed in 130 lesions in 101 patients during the study period. Their mean age was 52.5 ± 12 years and 42.5% were female. Pancreatic masses were the most common lesions (37.7% followed by lymph nodes (36.9%. Submucosal lesions (17.7% and liver lesions (7.7% accounted for rest of the cases. The overall diagnostic yield for EUS-FNAC (70% and CB (74.6% was not significantly different (P = 0.3 and their combined yield was 85.3%. For the 23 patients with submucosal lesion, diagnostic yield of CB (82.6% was significantly better than cytology (47.8%, P = 0.04. Conclusions: EUS-guided CB has better yield compared to cytology in gastrointestinal submucosal lesions. The combination of CB with cytology improves the overall yield of the procedure; and hence, they should be considered complimentary rather than alternatives.

  1. Effect and safety of deep needling and shallow needling for functional constipation: a multicenter, randomized controlled trial.

    Science.gov (United States)

    Wu, Jiani; Liu, Baoyan; Li, Ning; Sun, Jianhua; Wang, Lingling; Wang, Liping; Cai, Yuying; Ye, Yongming; Liu, Jun; Wang, Yang; Liu, Zhishun

    2014-12-01

    Aupuncture is widely used for functional constipation. Effect of acupuncture might be related to the depth of needling; however, the evidence is limited. This trial aimed to evaluate the effect and safety of deep needling and shallow needling for functional constipation, and to assess if the deep needling and shallow needling are superior to lactulose. We conducted a prospective, superiority-design, 5-center, 3-arm randomized controlled trial. A total of 475 patients with functional constipation were randomized to the deep needling group (237), shallow needling group (119), and lactulose-controlled group (119) in a ratio of 2:1:1. Sessions lasted 30 minutes each time and took place 5 times a week for 4 weeks in 2 acupuncture groups. Participants in the lactulose group took lactulose orally for 16 continuous weeks. The primary outcome was the change from baseline of mean weekly spontaneous bowel movements (SBMs) during week 1 to 4 (changes from the baselines of the weekly SBMs at week 8 and week 16 in follow-up period were also assessed simultaneously). Secondary outcomes were the weekly SBMs of each assessing week, the mean score change from the baseline of constipation-related symptoms over week 1 to 4, and the time to the first SBM. Emergency drug usage and adverse effects were monitored throughout the study.SBMs and constipation-related symptoms were all improved in the 3 groups compared with baseline at each time frame (Pdeep needling group, 2 (1.75) in the shallow needling group, and 2 (2) in the lactulose group (P>0.05, both compared with the lactulose group). The changes of mean weekly SBMs at week 8 and week 16 in the follow-up period were 2 (2), 2 (2.5) in the deep needling group, 2 (3), 1.5 (2.5) in the shallow needling group, and 1 (2), 1 (2) in the lactulose group (Pdeep or shallow needling group. Deep and shallow needling at Tianshu (ST25) can improve intestinal function remarkably and safely. Therapeutic effects of deep and shallow needling are not

  2. [Stiletto needle and needle-knife for influence of gravity index in treating knee osteoarthritis].

    Science.gov (United States)

    Gu, Li-Jun; Zhang, Bin; Li, Wen-Hua; Tang, Yan; Dong, Fu-Hui

    2017-12-25

    To explore stiletto needle and needle-knife for influence of double sufficient weight in treating knee osteoarthritis patients. One hundred and thirteen early and medium term knee osteoarthritis patients were randomly divided into three groups, including stiletto needle group(38 cases), needle-knife group (38 cases) and voltaren group (37 cases). In stiletto needle group, there were 13 males and 25 females with an average of(55.87±7.72) years old, treated by stiletto needle once a week, and 2 weeks were a course; there were 11 males and 27 females in needle-knife group with an average of(57.11±7.07) years old, treated by acupotome once a week, and 2 weeks were a course; there were 12 males and 25 females in voltaren group with an average age of(57.62±8.08) years old, treated by votalin emulsion smearing 3 to 5 cm on painful area of knee joint, three times a day for 2 weeks; 36 patients in normal group, including 11 males and 25 females with a mean age of (55.28±7.55) years old, treated with nothing. Gravitational four lattice used to measure bipedal back and forth load before and after treatment in further observe weight-bearing situation among three groups, d value, which was the distance from center of gravity to original point, was measured as a obvervational index, JOA score was used to evaluate clinical effect. Five patients were fall out, including 2 patients in stiletto needle group, 2 patients in needle-knife group and 1 patient in voltaren group. Other 108 patients were followed-up from 28 to 35 d with an average of 30 d, and without untoward effect. There was significant difference in d value between treatment group and control group at 1 month after treatment( P 0.05), and d value was decreased before treatment than that of after treatment. There was no significant difference in JOA score among treatment group after treatment at 1 month( P 0.05) after treatment at 1 month. Stiletto needle, needle-knife and voltaren for the treatment of knee

  3. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  4. [Design and application of silver needle-knife].

    Science.gov (United States)

    Sun, Guodong; Shi, Bin; Zhang, Benwu; Xu, Haidong

    2015-04-01

    A silver needle-knife which has the dual function of silver needle and needle-knife is designed. The main components of this silver needle-knife are approximately 50% silver and approximately 50% nichrome. The silver needle-knife is composed of five parts, including needle-knife tail, spiral handle; steering handle, needle-knife body and needle-knife edge. It converges the advantages of needle-knife and silver needle, which can cut loose of diseased tissue and peel adhesion of lesions, but also be heated with moxa cone and thermal therapeutic instrument, and connect with electroacupuncture apparatus. It has the function of warming channel and removing coldness, dispelling wind and eliminating dampness, resolving spasm and relieving pain, dredging the channel and so on. Due to the spiral handle and the steering handle, the operation is easier, which reduces the blindness of cutting and increase the safety. It is mainly used for soft tissue injury, rheumatism and rheumatoid arthritis, as well as degenerative diseases of spine and joint, and it has obvious efficacy on some internal medical diseases.

  5. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  6. Molecular testing guidelines for lung adenocarcinoma: Utility of cell blocks and concordance between fine-needle aspiration cytology and histology samples

    Science.gov (United States)

    Heymann, Jonas J.; Bulman, William A.; Maxfield, Roger A.; Powell, Charles A.; Halmos, Balazs; Sonett, Joshua; Beaubier, Nike T.; Crapanzano, John P.; Mansukhani, Mahesh M.; Saqi, Anjali

    2014-01-01

    Background: Lung cancer is a leading cause of mortality, and patients often present at a late stage. More recently, advances in screening, diagnosing, and treating lung cancer have been made. For instance, greater numbers of minimally invasive procedures are being performed, and identification of lung adenocarcinoma driver mutations has led to the implementation of targeted therapies. Advances in molecular techniques enable use of scant tissue, including cytology specimens. In addition, per recently published consensus guidelines, cytology-derived cell blocks (CBs) are preferred over direct smears. Yet, limited comparison of molecular testing of fine-needle aspiration (FNA) CBs and corresponding histology specimens has been performed. This study aimed to establish concordance of epidermal growth factor receptor (EGFR) and Kirsten rat sarcoma (KRAS) virus homolog testing between FNA CBs and histology samples from the same patients. Materials and Methods: Patients for whom molecular testing for EGFR or KRAS was performed on both FNA CBs and histology samples containing lung adenocarcinoma were identified retrospectively. Following microdissection, when necessary, concordance of EGFR and KRAS molecular testing results between FNA CBs and histology samples was evaluated. Results: EGFR and/or KRAS testing was performed on samples obtained from 26 patients. Concordant results were obtained for all EGFR (22/22) and KRAS (17/17) mutation analyses performed. Conclusions: Identification of mutations in lung adenocarcinomas affects clinical decision-making, and it is important that results from small samples be accurate. This study demonstrates that molecular testing on cytology CBs is as sensitive and specific as that on histology. PMID:24987443

  7. The Role of Fine Needle Aspiration in the Diagnosis of Parotid Gland Tumors: Correlation With Preoperative Computerized Tomography Tumor Size.

    Science.gov (United States)

    Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad

    2016-03-01

    The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).

  8. Molecular testing guidelines for lung adenocarcinoma: Utility of cell blocks and concordance between fine-needle aspiration cytology and histology samples

    Directory of Open Access Journals (Sweden)

    Jonas J. Heymann

    2014-01-01

    Full Text Available Background: Lung cancer is a leading cause of mortality, and patients often present at a late stage. More recently, advances in screening, diagnosing, and treating lung cancer have been made. For instance, greater numbers of minimally invasive procedures are being performed, and identification of lung adenocarcinoma driver mutations has led to the implementation of targeted therapies. Advances in molecular techniques enable use of scant tissue, including cytology specimens. In addition, per recently published consensus guidelines, cytology-derived cell blocks (CBs are preferred over direct smears. Yet, limited comparison of molecular testing of fine-needle aspiration (FNA CBs and corresponding histology specimens has been performed. This study aimed to establish concordance of epidermal growth factor receptor (EGFR and Kirsten rat sarcoma (KRAS virus homolog testing between FNA CBs and histology samples from the same patients. Materials and Methods: Patients for whom molecular testing for EGFR or KRAS was performed on both FNA CBs and histology samples containing lung adenocarcinoma were identified retrospectively. Following microdissection, when necessary, concordance of EGFR and KRAS molecular testing results between FNA CBs and histology samples was evaluated. Results: EGFR and/or KRAS testing was performed on samples obtained from 26 patients. Concordant results were obtained for all EGFR (22/22 and KRAS (17/17 mutation analyses performed. Conclusions: Identification of mutations in lung adenocarcinomas affects clinical decision-making, and it is important that results from small samples be accurate. This study demonstrates that molecular testing on cytology CBs is as sensitive and specific as that on histology.

  9. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  10. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [Institute of Ecology, South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-01-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd) and Al concentrations as well as values of Ca/Al in the tip, middle, base sections and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  11. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    Energy Technology Data Exchange (ETDEWEB)

    Kuang Yuanwen [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: kuangyw@scbg.ac.cn; Wen Dazhi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: dzwen@scbg.ac.cn; Zhou Guoyi [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: gyzhou@scbg.ac.cn; Liu Shizhong [South China Botanical Garden, Chinese Academy of Sciences, 510650 Guangzhou (China)]. E-mail: lsz@scbg.ac.cn

    2007-02-15

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants.

  12. Distribution of elements in needles of Pinus massoniana (Lamb.) was uneven and affected by needle age

    International Nuclear Information System (INIS)

    Kuang Yuanwen; Wen Dazhi; Zhou Guoyi; Liu Shizhong

    2007-01-01

    Macronutrients (P, S, K, Na, Mg, Ca), heavy metals (Fe, Zn, Mn, Cu, Pb, Cr, Ni, Cd,) and Al concentrations as well as values of Ca/Al in the tip, middle and base sections, and sheaths of current year and previous year needles of Pinus massoniana from Xiqiao Mountain were analyzed and the distribution patterns of those elements were compared. The results indicated that many elements were unevenly distributed among the different components of needles. Possible deficiency of P, K, Ca, Mn and Al toxicity occurred in needles under air pollution. Heavy metals may threaten the health of Masson pine. Needle sheaths were good places to look for particulate pollutants, in this case including Fe, Cu, Zn, Pb, Cr, Cd and Al. - Pine needle sections as bioindicator for heavy metals and nutrient deficiency particularly needle sheath for particle pollutants

  13. Automated Parallel Capillary Electrophoretic System

    Science.gov (United States)

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2000-02-22

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  14. Preoperative US-guided hook-needle insertion in recurrent lymph nodes of papillary thyroid cancer: A help for the surgeon

    International Nuclear Information System (INIS)

    Duprez, Raphaelle; Lebas, Patrick; Marc, Olivier Saint; Mongeois, Elise; Emy, Philippe; Michenet, Patrick

    2010-01-01

    Objective: The objective of this study is to investigate whether preoperative ultrasound guided insertion of a hook-needle is useful in reoperations for cervical recurrent lymph node metastases of papillary thyroid cancer. Patients and methods: 8 patients with operated papillary thyroid cancer were included in this study. They all had suspicious nonpalpable cervical lymph nodes discovered during follow-up. These lymph nodes were identified by ultrasound imaging and their metastatic nature was confirmed by fine needle aspiration cytology and measurement of in situ thyroglobulin. In all cases, surgical excision of these lymph nodes was decided. All 8 patients had a hook-needle inserted in the suspicious lymph node(s) preoperatively and under ultrasound guidance. Results and conclusion: In all 8 patients, the suspicious lymph nodes were removed and their metastatic nature was confirmed by the final pathological examination. This localization technique is very helpful for the surgeon during the excision of small and nonpalpable lymph nodes, especially in previously operated area.

  15. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  16. Fuzzy method for pre-diagnosis of breast cancer from the Fine Needle Aspirate analysis

    Directory of Open Access Journals (Sweden)

    Sizilio Gláucia RMA

    2012-11-01

    Full Text Available Abstract Background Across the globe, breast cancer is one of the leading causes of death among women and, currently, Fine Needle Aspirate (FNA with visual interpretation is the easiest and fastest biopsy technique for the diagnosis of this deadly disease. Unfortunately, the ability of this method to diagnose cancer correctly when the disease is present varies greatly, from 65% to 98%. This article introduces a method to assist in the diagnosis and second opinion of breast cancer from the analysis of descriptors extracted from smears of breast mass obtained by FNA, with the use of computational intelligence resources - in this case, fuzzy logic. Methods For data acquisition of FNA, the Wisconsin Diagnostic Breast Cancer Data (WDBC, from the University of California at Irvine (UCI Machine Learning Repository, available on the internet through the UCI domain was used. The knowledge acquisition process was carried out by the extraction and analysis of numerical data of the WDBC and by interviews and discussions with medical experts. The PDM-FNA-Fuzzy was developed in four steps: 1 Fuzzification Stage; 2 Rules Base; 3 Inference Stage; and 4 Defuzzification Stage. Performance cross-validation was used in the tests, with three databases with gold pattern clinical cases randomly extracted from the WDBC. The final validation was held by medical specialists in pathology, mastology and general practice, and with gold pattern clinical cases, i.e. with known and clinically confirmed diagnosis. Results The Fuzzy Method developed provides breast cancer pre-diagnosis with 98.59% sensitivity (correct pre-diagnosis of malignancies; and 85.43% specificity (correct pre-diagnosis of benign cases. Due to the high sensitivity presented, these results are considered satisfactory, both by the opinion of medical specialists in the aforementioned areas and by comparison with other studies involving breast cancer diagnosis using FNA. Conclusions This paper presents an

  17. EUS – Fine- Needle Aspiration Biopsy (FNAB in the Diagnosis of Pancreatic Adenocarcinoma: A Review

    Directory of Open Access Journals (Sweden)

    Kalogeraki Alexandra

    2016-03-01

    Full Text Available Solid masses of the pancreas represent a variety of benign and malignant neoplasms of the exocrine and endocrine tissues of the pancreas. A tissue diagnosis is often required to direct therapy in the face of uncertain diagnosis or if the patient is not a surgical candidate either due to advanced disease or comorbidities. Endoscopic ultrasound (EUS is a relatively new technology that employs endoscopy and high-frequency ultrasound (US. EUS involves imaging of the pancreatic head and the uncinate from the duodenum and imaging of the body and tail from the stomach. It has been shown to be a highly sensitive method for the detection of pancreatic masses. It is superior to extracorporeal US and computed tomographic (CT scans, especially when the pancreatic tumor is smaller than 2-3 cm. Although EUS is highly sensitive in detecting pancreatic solid masses, its ability to differentiate between inflammatory masses and malignant disease is limited. Endoscopic retrograde cholangiopancreatography (ERCP brushing, CT-guided biopsies, and transabdominal ultrasound (US have been the standard nonsurgical methods for obtaining a tissue diagnosis of pancreatic lesions, but a substantial false-negative rate has been reported. Transabdominal US-guided fine-needle aspiration biopsy (US-FNAB has been used for tissue diagnosis in patients with suspected pancreatic carcinoma. It has been shown to be highly specific, with no false-positive diagnoses. With the advent of curvilinear echoendoscopes, transgastric and transduodenal EUS-FNAB of the pancreas have become a reality EUS with FNAB has revolutionized the ability to diagnose and stage cancers of the gastrointestinal tract and assess the pancreas. Gastrointestinal cancers can be looked at with EUS and their depth of penetration into the intestinal wall can be determined. Any suspicious appearing lymph nodes can be biopsied using EUS/FNAB. The pancreas is another organ that is well visualized with EUS. Abnormalities

  18. Image-guided automated needle biopsy of 106 thoracic lesions: a retrospective review of diagnostic accuracy and complication rates

    International Nuclear Information System (INIS)

    Connor, S.; Dyer, J.; Guest, P.

    2000-01-01

    We reviewed the diagnostic accuracy and complication rates of transthoracic needle biopsy (TNB) with an automated 18-gauge core biopsy needle and gun, using either fluoroscopic or CT guidance. One hundred six lesions were biopsied in 103 patients between 1992 and 1998. Hard-copy images, imaging reports, pathology reports and clinical notes were reviewed. In 3 patients it was not possible to establish the lesion as either malignant or benign from the available follow-up, so these were removed from the analysis of diagnostic accuracy. Adequate samples for histological diagnosis were obtained in 104 of 106 (98 %) biopsies. There were 75 of 85 (88 %) true-positive core biopsies for malignant lesions and a specific cell type was identified in 70 of 85 (82 %) cases. A specific histological diagnosis was obtained in 12 of 18 (66 %) biopsies. There was a 19 % rate of pneumothorax with only 2.4 % requiring drainage. Minor haemoptysis occurred in 3.8 % of procedures. The TNB technique with an automated core biopsy needle provides a high level of diagnostic accuracy, effectively distinguishes cell type in malignancy and provides a definite diagnosis in benign disease more frequently than fine needle aspiration (FNA). There is no increased complication rate compared with FNA. (orig.)

  19. Impacts on oil recovery from capillary pressure and capillary heterogeneities

    Energy Technology Data Exchange (ETDEWEB)

    Bognoe, Thomas

    2008-07-01

    The main conclusions drawn from this thesis are; 7 scientific papers are published on a broad variety of subjects, and describes in detail the experiments and research treated in this thesis. Scientific research has been performed, investigating the subjects of capillary pressure and capillary heterogeneities from different angles. This thesis discusses the findings in this study and aims to illustrate the benefits of the results obtained for further development of other experiments, and/or even the industrial benefits in field development. The methods for wettability alteration have developed throughout the work. From producing heterogeneous wettability alterations, the methods have improved to giving both radial and lateral uniform wettability alterations, which also remains unaltered throughout the duration of the experimental work. The alteration of wettability is dependent on initial water saturation, flow rate, aging time and crude oil composition. Capillary pressure and relative permeability curves have been measured for core plugs at different wettabilities using conventional centrifuge methods. The trends observed are mostly consistent with theory. The production mechanisms of strongly and moderately water wet chalk has been investigated. At strongly water wet conditions in fractured chalk; the flow is governed by capillary forces, showing strong impact from the fractures. At moderately water wet conditions, the impact of the fractures are absent, and a dispersed water front is observed during the displacement. The oil recovery is about the same, at the two wettabilities. Fracture crossing mechanisms at the same wettability conditions have been mapped. And the observations are consistent with those of the water floods. During strongly water wet displacement, the fracture crossing is occurring once the inlet core has reached endpoint of spontaneous imbibition. At moderately water wet conditions the fracture crossing is less abrupt, and creation of wetting

  20. [Needling technique of Professor Li Yan-Fang].

    Science.gov (United States)

    Li, Li-Jun

    2014-01-01

    Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the

  1. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography

    International Nuclear Information System (INIS)

    Kazarian, Artaches A.; Sanz Rodriguez, Estrella; Deverell, Jeremy A.; McCord, James; Muddiman, David C.; Paull, Brett

    2016-01-01

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L"−"1 levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min"−"1, and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L"−"1 for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%. - Highlights: • Novel PS-DVB modified photonic crystal fibres for in-capillary micro-extraction. • New method for micro-extraction of PAHs and HPLC-FL detection at sub-ppb levels. • Demonstration of PS-DVB modified photonic crystal fibres for capillary bioseparations.

  2. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian, Artaches A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Sanz Rodriguez, Estrella; Deverell, Jeremy A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); McCord, James; Muddiman, David C. [W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Paull, Brett, E-mail: Brett.Paull@utas.edu.au [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); ARC Centre of Excellence for Electromaterials Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia)

    2016-01-28

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L{sup −1} levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min{sup −1}, and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L{sup −1} for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%. - Highlights: • Novel PS-DVB modified photonic crystal fibres for in-capillary micro-extraction. • New method for micro-extraction of PAHs and HPLC-FL detection at sub-ppb levels. • Demonstration of PS-DVB modified photonic crystal fibres for capillary bioseparations.

  3. A novel prototype 3/5 laparoscopic needle driver: A validation study with conventional laparoscopic needle driver.

    Science.gov (United States)

    Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay

    2018-01-01

    The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.

  4. Comparative cyto-histological study of needle tip aspirates and entry sites after intravitreal injection using different needle types.

    Directory of Open Access Journals (Sweden)

    Lyubomyr Lytvynchuk

    Full Text Available A comparison of the cellular content of needle tip aspirates and entry sites after transconjunctival intravitreal injection (IVI using different needle types was performed. White outbred rats and human cadaver eyes were used for IVI by hypodermic 27 gauge (G and 30G needles, and spinal anesthesia Pencan 27G needles. Aspiration of vitreous for quantitative morphological and cell cultivation analysis, as well as cyto-histological analysis of aspirates and entry sites were carried out. The most common cells in the aspirates from all needle types were conjunctival epithelial-, ciliary body non-pigmented epithelial- and sclerocyte-like cells and granular proteins. Crystallized vitreous specimens were present in each aspirate. The entry sites of hypodermic needles showed marked trauma in all wall layers of rat and human eyes accompanied by cellular destruction and hemorrhages. Pencan 27G needle caused less tissue trauma with partial reposition of sclerocytes. Transconjunctival IVIs with hypodermic 27G and 30G, and Pencan 27G needles result in trauma of all layers of the eyeball. The possible consequences of cellular content being cut and injected into the eye, as well as the entry site wound shape deserve future consideration and improvements.

  5. Physical Properties Of Acupuncture Needles: Do Disposable Acupuncture Needles Break With Normal Use

    Science.gov (United States)

    2016-06-01

    Orofacial Pain Graduate...JOURNAL PHYSICAL PROPERTIES OF ACUPUNCTURE NEEDLES: DO DISPOSABLE ACUPUNCTURE NEEDLES BREAK WITH NORMAL USE? James Kyle Vick DDS, Orofacial Pain ...MS CAPT, DC, USN Orofacial Pain Department Head Naval Postgraduate Dental School vi    TABLE OF CONTENTS GUIDELINE I. TITLE

  6. Is fine needle aspiration cytology a useful diagnostic tool for granular cell tumors? A cytohistological review with emphasis on pitfalls

    Directory of Open Access Journals (Sweden)

    Jason Koshy

    2014-01-01

    Full Text Available Background: Granular cell tumors (GCT formerly known as Abrikossoff tumor or granular cell myoblastoma, are rare neoplasms encountered in the fine needle aspiration (FNA service. Named because of their highly granular cytoplasm which is invariably positive for the S-100 antibody, the classic GCT is thought to be of neural origin. The cytomorphological features range from highly cellular to scanty cellular smears with dispersed polygonal tumor cells. The cells have abundant eosinophilic granular cytoplasm, eccentric round to oval vesicular nuclei with small inconspicuous nucleoli. The fragility of the cells can result in many stripped nuclei in a granular background. The differential diagnosis occasionally can range from a benign or reactive process to features that are suspicious for malignancy. Some of the concerning cytologic features include necrosis, mitoses and nuclear pleomorphism. Methods: We identified 6 cases of suspected GCT on cytology within the last 10 years and compared them to their final histologic diagnoses. Results: Four had histologic correlation of GCT including one case that was suspicious for GCT on cytology and called atypical with features concerning for a malignant neoplasm. Of the other two cases where GCT was suspected, one showed breast tissue with fibrocystic changes, and the other was a Hurthle cell adenoma of the thyroid. Conclusions: These results imply that FNA has utility in the diagnosis of GCT, and should be included in the differential diagnoses when cells with abundant granular cytoplasm are seen on cytology. Careful attention to cytologic atypia, signs of reactive changes, use of immunohistochemistry, and clinical correlation are helpful in arriving at a definite diagnosis on FNA cytology.

  7. From Mount Sinai to Mount Scopus: differences in the role and value of fine needle aspiration for evaluating thyroid nodules.

    Science.gov (United States)

    Mazeh, Haggi; Greenstein, Alexander; Swedish, Kristin; Arora, Shalini; Hermon, Hila; Ariel, Ilana; Divino, Celia; Freund, Herbert R; Weber, Kaare

    2009-05-01

    Fine needle aspiration is the main diagnostic tool used to assess thyroid nodules. To correlate FNA cytology results with surgical pathological findings in two teaching medical centers across the Atlantic. We retrospectively identified 484 patients at Hadassah Hebrew University Medical Center, Jerusalem and Mount Sinai Hospital, New York, by means of both preoperative FNA cytology and a final histopathological report. Results compared FNA diagnosis, histological findings and frozen section results (Mt. Sinai only). The sensitivity value of FNA at Hadassah was 83.0% compared with 79.1% at Mt. Sinai (NS). Specificity values were 86.6 vs. 98.5% (P < 0.05), negative predictive value 78.7 vs. 77.6% (NS) and positive predictive value 89.7 vs. 98.6% (P < 0.05), respectively. "Follicular lesion" was diagnosed on FNA in 33.1% of the patients at Hadassah and in 21.5% at Mt Sinai (P < 0.005) with a malignancy rate of 42.5 vs. 23.1% (P < 0.05), respectively. Frozen section was used in 190 patients at Mt. Sinai (78.5%) with sensitivity and specificity values of 72.3% and 100%. Frozen section results altered the planned operative course in only 6 patients (2.5%). Follicular carcinoma was diagnosed in 12 patients at Hadassah vs. 2 patients at Mt. Sinai (P < 0.05). The sensitivity of FNA at the two institutions was comparable. While malignancy on frozen section is highly specific, it should be used selectively for suspicious FNA results. Follicular lesions and the rate of malignancy in such lesions were more common at Hadassah, favoring a more aggressive surgical approach.

  8. Benefits and limitations of fine needle aspiration cytology in the diagnosis and classification of leprosy in primary and secondary healthcare settings.

    Science.gov (United States)

    Ray, R; Mondal, R K; Pathak, S

    2015-08-01

    The goal of the World Health Organization (WHO) is to eliminate leprosy as a public health problem. This will only be possible when all patients are detected and cured using multidrug therapy, which requires accurate diagnosis prior to treatment. The objective of this study was to evaluate the possibility of the diagnosis of leprosy lesions by fine needle aspiration cytology according to a modification of the Ridley-Jopling scale, as it can be used in primary and secondary healthcare centres, especially in low-resource settings in which leprosy is prevalent. A prospective study comprising 54 cases with cardinal features of leprosy was performed. Among the 54 cases, 27 patients consented to a histopathological biopsy procedure. The slides were stained with Giemsa, modified Ziehl-Neelsen, Papanicolaou and haematoxylin and eosin methods. Among the 54 cases, 34 were reported as tuberculoid leprosy, five as mid-borderline (BB), three as borderline lepromatous (BL) and eight as lepromatous leprosy (LL); four were unsatisfactory. Histopathological study was performed in 27 cases, which showed cyto-histological correlation in 21 cases (78%). Agreement between histological and cytological diagnosis was achieved in 12 of the 15 tuberculoid cases, one of the three BB cases, one of the two BL cases and all seven LL cases. With the implementation of the WHO classification based on patch counting, there is the possibility of the over-treatment of paucibacillary cases and under-treatment of multibacillary cases. Cytology in terms of cellular type morphology and bacteriological study can complement the WHO classification. © 2014 John Wiley & Sons Ltd.

  9. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  10. Capillaries modified by noncovalent anionic polymer adsorption for capillary zone electrophoresis, micellar electrokinetic capillary chromatography and capillary electrophoresis mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L; Hansen, S H; Gammelgaard, Bente

    2001-01-01

    A simple coating procedure for generation of a high and pH-independent electroosmotic flow in capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) is described. The bilayer coating was formed by noncovalent adsorption of the ionic polymers Polybrene...... capillaries was (4.9+/-0.1) x 10(-4) cm2V(-1)s(-1) in a pH-range of 2-10 (ionic strength = 30 mM). When alkaline compounds were used as test substances intracapillary and intercapillary migration time variations (n = 6) were less than 1% relative standard deviation (RSD) and 2% RSD, respectively in the entire...... pH range. The coating was fairly stable in the presence of sodium dodecyl sulfate, and this made it possible to perform fast MEKC separations at low pH. When neutral compounds were used as test substances, the intracapillary migration time variations (n = 6) were less than 2% RSD in a pH range of 2...

  11. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  12. Physiological factors influencing capillary growth.

    Science.gov (United States)

    Egginton, S

    2011-07-01

    (1) Angiogenesis (growth of new capillaries from an existing capillary bed) may result from a mismatch in microvascular supply and metabolic demand (metabolic error signal). Krogh examined the distribution and number of capillaries to explore the correlation between O(2) delivery and O(2) consumption. Subsequently, the heterogeneity in angiogenic response within a muscle has been shown to reflect either differences in fibre type composition or mechanical load. However, local control leads to targetted angiogenesis in the vicinity of glycolytic fibre types following muscle stimulation, or oxidative fibres following endurance training, while heterogeneity of capillary spacing is maintained during ontogenetic growth. (2) Despite limited microscopy resolution and lack of specific markers, Krogh's interest in the structure of the capillary wall paved the way for understanding the mechanisms of capillary growth. Angiogenesis may be influenced by the response of perivascular or stromal cells (fibroblasts, macrophages and pericytes) to altered activity, likely acting as a source for chemical signals modulating capillary growth such as vascular endothelial growth factor. In addition, haemodynamic factors such as shear stress and muscle stretch play a significant role in adaptive remodelling of the microcirculation. (3) Most indices of capillarity are highly dependent on fibre size, resulting in possible bias because of scaling. To examine the consequences of capillary distribution, it is therefore helpful to quantify the area of tissue supplied by individual capillaries. This allows the spatial limitations inherent in most models of tissue oxygenation to be overcome generating an alternative approach to Krogh's tissue cylinder, the capillary domain, to improve descriptions of intracellular oxygen diffusion. © 2010 The Author. Acta Physiologica © 2010 Scandinavian Physiological Society.

  13. Effect of anti-vertigo granule on the opening number and blood flow of mouse ear capillary network

    Science.gov (United States)

    Li, Chongxian; Liu, Xiaobin; Li, Jun; Hao, Shaojun; Wang, Xidong; Li, Wenjun; Zhang, Zhengchen

    2018-04-01

    To observe the effects of anti-glare particles on the open number and blood flow in the auricle of mice with microcirculation disturbance model. Sixty mice, half male and half female, were randomly divided into 6 groups. The mice were given Kangxuan granule suspension, serum brain granule suspension and normal saline of the same volume, respectively, once a day. The mice were anesthetized by intraperitoneal injection of chloral hydrate at 1 hour after the last administration. The mouse was fixed on the observation platform and the auricle was placed on the transmission stage. BZ-2000 microcirculation microscope and microcirculation analysis system were used to observe the changes of blood velocity and capillary opening volume in auricle of mice before administration. The changes of blood velocity and capillaries opening volume of mouse auricle were observed 2 min after epinephrine injection into tail vein of mice. Bear fruit: Compared with those before epinephrine, the opening number of capillary reticulum of auricle in large dose Kangxuan granule group was significantly decreased (Pgroup and middle group. In the small dose Kangxuan granule group, the opening number of capillary network of auricle decreased significantly (Pgroup, the large dose Kangxuan granule group could significantly increase the opening number of the auricle capillary network in mice (Pgroup could significantly increase the opening number of auricle capillary reticulum in mice (Pgroup by Ridit test. Both Kangxuan granule group and Yangxuannao granule group could significantly improve the auricle hair of mice with microcirculation disorder. The blood flow in fine blood vessels (Pblood flow in mice with microcirculation disorder.

  14. Analysis of the NovoTwist pen needle in comparison with conventional screw-thread needles.

    Science.gov (United States)

    Aye, Tandy

    2011-11-01

    Administration of insulin via a pen device may be advantageous over a vial and syringe system. Hofman and colleagues introduce a new insulin pen needle, the NovoTwist, to simplify injections to a small group of children and adolescents. Their overall preferences and evaluation of the handling of the needle are reported in the study. This new needle has the potential to ease administration of insulin via a pen device that may increase both the use of a pen device and adherence to insulin therapy. © 2011 Diabetes Technology Society.

  15. Nanoparticle-based capillary electroseparation of proteins in polymer capillaries under physiological conditions

    DEFF Research Database (Denmark)

    Nilsson, C.; Harwigsson, I.; Becker, K.

    2010-01-01

    Totally porous lipid-based liquid crystalline nanoparticles were used as pseudostationary phase for capillary electroseparation with LIF detection of proteins at physiological conditions using unmodified cyclic olefin copolymer capillaries (Topas (R), 6.7 cm effective length). In the absence of n...... at protein friendly conditions. The developed capillary-based method facilitates future electrochromatography of proteins on polymer-based microchips under physiological conditions and enables the initial optimization of separation conditions in parallel to the chip development....

  16. Intra-operative navigation of a 3-dimensional needle localization system for precision of irreversible electroporation needles in locally advanced pancreatic cancer.

    Science.gov (United States)

    Bond, L; Schulz, B; VanMeter, T; Martin, R C G

    2017-02-01

    Irreversible electroporation (IRE) uses multiple needles and a series of electrical pulses to create pores in cell membranes and cause cell apoptosis. One of the demands of IRE is the precise needle spacing required. Two-dimensional intraoperative ultrasound (2-D iUS) is currently used to measure inter-needle distances but requires significant expertise. This study evaluates the potential of three-dimensional (3-D) image guidance for placing IRE needles and calculating needle spacing. A prospective clinical evaluation of a 3-D needle localization system (Explorer™) was evaluated in consecutive patients from April 2012 through June 2013 for unresectable pancreatic adenocarcinoma. 3-D reconstructions of patients' anatomy were generated from preoperative CT images, which were aligned to the intraoperative space. Thirty consecutive patients with locally advanced pancreatic cancer were treated with IRE. The needle localization system setup added an average of 6.5 min to each procedure. The 3-D needle localization system increased surgeon confidence and ultimately reduced needle placement time. IRE treatment efficacy is highly dependent on accurate needle spacing. The needle localization system evaluated in this study aims to mitigate these issues by providing the surgeon with additional visualization and data in 3-D. The Explorer™ system provides valuable guidance information and inter-needle distance calculations. Copyright © 2016 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  17. Western Blotting using Capillary Electrophoresis

    OpenAIRE

    Anderson, Gwendolyn J.; Cipolla, Cynthia; Kennedy, Robert T.

    2011-01-01

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein a...

  18. Effect of Blinding With a New Pragmatic Placebo Needle

    Science.gov (United States)

    Liu, Baoyan; Xu, Huanfang; Ma, Rui; Mo, Qian; Yan, Shiyan; Liu, Zhishun

    2014-01-01

    Abstract Placebo control is a useful method for determining the efficacy of a therapy. In acupuncture researches, the preferred method for placebo control is acupuncture using a placebo needle that has a blunt tip and achieves no skin penetration. We performed a crossover study to validate the blinding effect of a new type of placebo needle. Sixty volunteers were randomized to receive acupuncture using 2 types of needles with different sequences: sequence AB, involving first the pragmatic placebo needle and then the real needle, and sequence BA, in a reverse order. Placebo acupuncture was performed by administering the placebo needle through an adhesive pad without skin penetration on the acupoints LI4, RN12, BL25, and BL36. Real acupuncture was performed by needling through the pad and penetrating the skin to 15 mm using a real needle on the same acupoints. The acupuncture was administered every other day with 3 sessions for 1 type of needle. The primary outcome was the perception of needle penetration. Besides degree of acupuncture pain, type, and degree of needle sensation, needle acceptability and factors influencing the subject blinding effect were assessed. Needle penetration was felt by 100%, 90% (54/60), 88.3% (53/60), and 95% (57/60) of volunteers receiving placebo acupuncture and 98.3% (59/60), 96.7% (58/60), 95% (57/60), and 95% (57/60) of volunteers receiving real acupuncture on LI4, RN12, BL25, and BL36, respectively. Differences of the volunteers’ perception of needle penetration between the placebo needle and real needle were not significant for the 4 acupoints (all P > 0.05). Volunteers experienced fewer distension sensations (P = 0.01), a lower degree of needle sensation (P = 0.007), and less pain (P = 0.006) during placebo acupuncture than during real acupuncture. The placebo needle was more easily accepted than the real needle (OR = 1.63, 95% CI, 1.01–2.64). The influences of age, sex, educational level, acupuncture

  19. Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration Cytology (SP-US-FNAC) Shortens Time for Diagnosis of Thyroid Nodules.

    Science.gov (United States)

    Gu, Wei Xiang; Tan, Chuen Seng; Ho, Thomas W T

    2014-06-01

    Ultrasound-guided fine-needle aspiration cytology (US-FNAC) of thyroid nodules is an important diagnostic procedure. In most hospitals, patients are referred to radiologists for US-FNAC, but this often results in a long waiting time before results are available. Surgeon-performed US-FNAC (SP-US-FNAC) during the initial patient consultation attempts to reduce the waiting time but it is not known whether this is as accurate as radiologist-performed US-FNAC (RP-US-FNAC). The aim of this study is to compare the clinical efficiency between SP-US-FNAC and RP-US-FNAC. A retrospective study was performed on patients from the Department of General Surgery, Tan Tock Seng Hospital (TTSH) who underwent an US-FNAC from August 2011 to May 2012. All cases of SP-US-FNAC were performed by a single surgeon. This study compared the rates of positive diagnoses achieved by SP-US-FNAC and RPUS- FNAC as well as the time interval to reach a cytological diagnosis by each group. A total of 40 cases of SP-US-FNAC and 72 cases of RP-US-FNAC were included in the study. SP-US-FNAC resulted in 28 (70%) positive diagnoses and 12 (30%) nondiagnoses while RP-US-FNAC resulted in 47 (65.3%) positive diagnoses and 25 (34.7%) non-diagnoses. These results were comparable (P=0.678). The median time taken to reach a cytological diagnosis was 1 working day for SP-US-FNAC and 29.5 working days for RP-US-FNAC resulting in a shorter interval to reaching a cytological diagnosis for SP-US-FNAC (P<0.001). In the workup of thyroid nodules, SP-US-FNAC is as accurate as RP-US-FNAC but significantly reduces the time taken to reach a cytological diagnosis. This leads to greater clinical efficiency in the management of patients with thyroid nodules, which in turn leads to other benefits such as decreased patient anxiety and increased patient satisfaction.

  20. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  1. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  2. Radiological and cytological correlation of neoplastic lesions of the breast diagnosed by fine needle aspiration biopsy guided with ultrasound at the Hospital San Juan de Dios in the year 2009

    International Nuclear Information System (INIS)

    Madriz Meza, Wendy P.

    2011-01-01

    Mortality from breast cancer has been increased, going on to occupy the first place of the malignant neoplasms in women with a percentage increase of over 45% in 10 years. A bibliographic search demonstrates that have not been performed works that allow to establish the clinical and radiological characteristics of the lesions who have been diagnosed as mammary neoplasms by fine needle aspiration biopsy at the Hospital San Juan de Dios. A observational job, descriptive, longitudinal, retrospective is pretended to perform, to provide an instrument of guidance to the radiologist about the characteristics of alarm on a breast lesion. Female patients ascribed to the Hospital San Juan de Dios, with breast cancer diagnosed by guided fine needle puncture with echography during the year 2009 are included in the study. Data from 39 patients that fulfilled with all the inclusion criteria were presented. The data obtained were collected by reviewing of clinical records; which were found only women, who in their majority were from the province of San Jose, the most affected age group by the five-year periods has been of 45-49 years, followed by the groups between 40-44 years and 50-54 years. The greater part of cases has treated of unique injuries, almost all have been unilateral and measure the size of all the lesions was 21 mm. The injuries have been primarily in the right breast and the upper outer quadrant. The level of radiological success has been good in cases where was used the BIRADS, because it was classified with 4c or 5 to 52,4% of cases, however, it should be noted that in 17 of 39 cases were not properly categorized BIRADS. The main conclusions of this study are: women whose ages are between 45 and 55 years have been especially prone to mammary neoplasms, these lesions are found primarily in upper outer quadrants and measured more than 2 cm. The health problems generated in the patients with these diagnoses have made important to prioritize your attention once

  3. Numerical Modelling of Mutual Effect among Nearby Needles in a Multi-Needle Configuration of an Atmospheric Air Dielectric Barrier Discharge

    Directory of Open Access Journals (Sweden)

    Xiaoxing Zhang

    2012-05-01

    Full Text Available A numerical study has been conducted to understand the mutual effect among nearby needles in a multi-needle electrode dielectric barrier discharge. In the present paper, a fluid-hydrodynamic model is adopted. In this model, the mutual effect among nearby needles in a multi-needle configuration of an atmospheric air dielectric barrier discharge are investigated using a fluid-hydrodynamic model including the continuity equations for electrons and positive and negative ions coupled with Poisson’s equation. The electric fields at the streamer head of the middle needle (MN and the side needles (SNs in a three-needle model decreased under the influence of the mutual effects of nearby needles compared with that in the single-needle model. In addition, from the same comparison, the average propagation velocities of the streamers from MN and SNs, the electron average energy profile of MN and SNs (including those in the streamer channel, at the streamer head, and in the unbridged gap, and the electron densities at the streamer head of the MN and SNs also decreased. The results obtained in the current paper agreed well with the experimental and simulation results in the literature.

  4. The effects of needle deformation during lumbar puncture

    Directory of Open Access Journals (Sweden)

    Hasan Hüseyin Özdemir

    2015-01-01

    Full Text Available Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP. Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1% of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3% of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%. Forty-seven (41.5% patients experienced post lumbar puncture headache (PLPH and 13 (11.5% patients experienced intracranial hypotension (IH. No statistically significant correlation between the degree of deflection and headache was found (P > 0.05. Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  5. The effects of needle deformation during lumbar puncture

    Science.gov (United States)

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  6. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  7. Control of evaporation by geometry in capillary structures. From confined pillar arrays in a gap radial gradient to phyllotaxy-inspired geometry.

    Science.gov (United States)

    Chen, Chen; Duru, Paul; Joseph, Pierre; Geoffroy, Sandrine; Prat, Marc

    2017-11-08

    Evaporation is a key phenomenon in the natural environment and in many technological systems involving capillary structures. Understanding the evaporation front dynamics enables the evaporation rate from microfluidic devices and porous media to be finely controlled. Of particular interest is the ability to control the position of the front through suitable design of the capillary structure. Here, we show how to design model capillary structures in microfluidic devices so as to control the drying kinetics. This is achieved by acting on the spatial organization of the constrictions that influence the invasion of the structure by the gas phase. Two types of control are demonstrated. The first is intended to control the sequence of primary invasions through the pore space, while the second aims to control the secondary liquid structures: films, bridges, etc., that can form in the region of pore space invaded by the gas phase. It is shown how the latter can be obtained from phyllotaxy-inspired geometry. Our study thus opens up a route toward the control of the evaporation kinetics by means of tailored capillary structures.

  8. Flow cytometry of fine-needle-aspiration biopsies: a new method to monitor the intrahepatic immunological environment in chronic viral hepatitis

    NARCIS (Netherlands)

    Sprengers, D.; van der Molen, R. G.; Kusters, J. G.; Kwekkeboom, J.; van der Laan, L. J. W.; Niesters, H. G. M.; Kuipers, E. J.; de Man, R. A.; Schalm, S. W.; Janssen, H. L. A.

    2005-01-01

    SUMMARY: Information about the character and grade of the intrahepatic immune response in viral hepatitis is important for the evaluation of disease stage and effect of therapy. Complications like haemorrhage limit the frequent performance of tissue-needle biopsies (TB), and the cells of peripheral

  9. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  10. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    needle is used to insert high strength yarns (i.e., threads) through the dry fabric or prepreg laminate , leaving a loose thread loop underneath [9-11...capability which uses commercially-available felting needles to insert z-fibers into composite laminates at different angles (±45/90°) relative to the... laminate plane. Previous work with needled glass/epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  11. Capillary gas-solid chromatography

    International Nuclear Information System (INIS)

    Berezkin, V.G.

    1996-01-01

    Modern state of gas adsorption chromatography in open capillary columns has been analyzed. The history of the method development and its role in gas chromatography, ways to construct open adsorptional capillary columns, foundations of the theory of retention and washing of chromatographic regions in gas adsorption capillary columns have been considered. The fields is extensively and for analyzing volatile compounds of different isotopic composition, inorganic and organic gases, volatile organic polar compounds, aqueous solutions of organic compounds. Separation of nuclear-spin isomers and isotopes of hydrogen is the first illustrative example of practical application of the adsorption capillary chromatography. It is shown that duration of protium and deuterium nuclear isomers may be reduced if the column temperature is brought to 47 K

  12. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  13. Ultrasonography-guided fine-needle aspiration biopsy for thyroid nodules: effective technique and a peculiar smear method

    International Nuclear Information System (INIS)

    Park, Kyeong Rok; Rho, Myung Ho; Kim, Dong Wook; Koo, Yong Woon; Lee, Kyeong Hee; Kang, Tae Woo

    2006-01-01

    We wanted to evaluate the effective methods that are appropriate for an endemic area of thyroid disease and to compare the differences of cytologic diagnostic rates with and without using a peculiar smear technique. We analyzed the incidence rate of insufficient results, complications and the total procedure times of 1,126 thyroid nodules in 776 patients who underwent US-FNAB (ultrasonography-guided fine-needle aspiration biopsy) from January to December 2005. We compared the diagnostic rate between the two groups; the groups' tests were performed with a peculiar smear technique (Group A, n 313) or with a ventional smear technique (Group B, n = 250). According to the size of the thyroid nodule, the incidence rate of an insufficient result on US-FNAB and the mean total procedure time for 1126 thyroid nodules in 776 patients were measured as 16.9% (52/308) and 208 seconds for nodules under 0.5 cm, 9.8% (30/306) and 160 seconds for nodules between 0.5 cm-10 cm, and 6.0% (30/504) and 134 seconds for nodules over 1.0 cm. These 776 patients showed no significant complication, except for mild pain. In Group A, the incidence rate of an insufficient result was calculated as 15.1% (14/93) for the group with nodules under 0.5 cm, 5.3% (5/95) for the group with nodules between 0.5 cm-1.0 cm, 4.8% (6/125) for the group with nodules over 1.0 cm, and 8.0% (25/313) for the total A Group. In Group B, the incidence rate of an insufficient result was measured as 33.3% (15/45) for the group with nodules under 0.5 cm, 28.1% (25/89) for the group with nodules between 0.5 cm-1.0 cm, 21.4% (24/112) for the group with nodules over 1.0 cm, and 25.7% (63/245) for the total B group. There was a statistically significant correlation between the rate of an insufficient result and the peculiar smear technique or the size of the thyroid nodule. We consider that US-FNAB is very simple, safe and accurate diagnostic method for thyroid nodules, and US-FNAB with a peculiar smear technique is able to

  14. Growth of metal-organic framework HKUST-1 in capillary using liquid-phase epitaxy for open-tubular capillary electrochromatography and capillary liquid chromatography.

    Science.gov (United States)

    Bao, Tao; Zhang, Juan; Zhang, Wenpeng; Chen, Zilin

    2015-02-13

    Much attention is being paid to applying metal-organic frameworks (MOFs) as stationary phases in chromatography because of their fascinating properties, such as large surface-to-volume ratios, high levels of porosity, and selective adsorption. HKUST-1 is one of the best-studied face-centered-cubic MOF containing nano-sized channels and side pockets for film growth. However, growth of HKUST-1 framework inside capillary column as stationary phase for capillary electrochromatography is a challenge work. In this work, we carry out the growth of HKUST-1 on the inner wall of capillary by using liquid-phase epitaxy process at room temperature. The fabricated HKUST-1@capillary can be successfully used for the separation of substituted benzene including methylbenzene, ethylbenzene, styrene, chlorobenzene, bromobenzene, o-dichlorobenzene, benzene series, phenolic acids, and benzoic acids derivates. High column efficiency of 1.5×10(5) N/m for methylbenzene was achieved. The formation of HKUST-1 grown in the capillary was confirmed and characterized by scanning electron microscopy images, Fourier transform infrared spectra and X-ray diffraction. The column showed long lifetime and excellent stability. The relative standard deviations for intra-day and inter-day repeatability of the HKUST-1@capillary were lower than 7%. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Needle thoracostomy in the treatment of a tension pneumothorax in trauma patients: what size needle?

    Science.gov (United States)

    Zengerink, Imme; Brink, Peter R; Laupland, Kevin B; Raber, Earl L; Zygun, Dave; Kortbeek, John B

    2008-01-01

    A tension pneumothorax requires immediate decompression using a needle thoracostomy. According to advanced trauma life support guidelines this procedure is performed in the second intercostal space (ICS) in the midclavicular line (MCL), using a 4.5-cm (2-inch) catheter (5-cm needle). Previous studies have shown a failure rate of up to 40% using this technique. Case reports have suggested that this high failure rate could be because of insufficient length of the needle. To analyze the average chest wall thickness (CWT) at the second ICS in the MCL in a trauma population and to evaluate the length of the needle used in needle thoracostomy for emergency decompression of tension pneumothoraces. Retrospective review of major trauma admissions (Injury Severity Score >12) at the Foothills Medical Centre in Calgary, Canada, who underwent a computed tomography chest scan admitted in the period from October 2001 until March 2004. Subgroup analysis on men and women, /=40 years of age was defined a priori. CWT was measured to the nearest 0.01 cm at the second ICS in the MCL. The mean CWT in the 604 male patients and 170 female patients studied averaged 3.50 cm at the left second ICS MCL and 3.51 cm on the right. The mean CWT was significantly higher for women than men (p 4.5 cm and 24.1% to 35.4% of the women studied. A catheter length of 4.5 cm may not penetrate the chest wall of a substantial amount (9.9%-35.4%) of the population, depending on age and gender. This study demonstrates the need for a variable needle length for relief of a tension pneumothorax in certain population groups to improve effectiveness of needle thoracostomy.

  16. Comparison of Thin-Prep and cell block preparation for the evaluation of Thyroid epithelial lesions on fine needle aspiration biopsy

    Directory of Open Access Journals (Sweden)

    Hammoud Jamal

    2008-01-01

    Full Text Available Abstract Background The objective of this study was to compare the utility of Thin-Prep (TP cytologic preparation with that of Cell Block (CB preparation in the diagnosis of thyroid lesions, mainly follicular epithelial lesions, by fine needle aspiration biopsy (FNAB. Feasibility of using the TP slides for immunocytochemical stains is also discussed. Methods A total of 126 consecutive cases of thyroid FNAB with TP slides and 128 consecutive cases of thyroid FNAB with CB slides were reviewed blindly by two cytopathologists. The presence of colloid, follicular cells, macrophages and lymphocytes/plasma cells were recorded and scored 0–4 on each case based on TP or CB slide review. The cytologic diagnoses were grouped as follows: cyst, colloid nodule, colloid nodule with cystic change, chronic thyroiditis, atypical/neoplastic and non-diagnostic. Results The TP slides had higher diagnostic rate than CB slides. The diagnostic yield was 68% of the TP slides whereas only 24% of the CB slides were diagnostic. Also, only 4 atypical/neoplastic lesions were diagnosed on the TP slides and the corresponding direct smears, while 5 cases of atypical/neoplastic lesions were diagnosed on the smears but could not be diagnosed on the corresponding CB slides. Additionally, the TP slides revealed cytologic features that were not observed on the direct traditional smears of the same case. Conclusion In thyroid FNAB cases, TP slide preparation is superior to CB slide preparation and is more likely to have greater cellularity for diagnosis and detect atypical/neoplastic thyroid lesions, particularly those of follicular cell origin. Furthermore, TP slides appear to detect helpful diagnostic cytologic features and should be considered complementary to, rather than replacing, direct smears.

  17. The rational use of fine needle aspiration biopsy (FNAB) in diagnosing thyroid nodules.

    Science.gov (United States)

    Sidoti, M; Marino, G; Resmini, E; Augeri, C; Cappi, C; Cavallero, D; Lagasio, C; Ceppa, P; Minuto, F; Giusti, M

    2006-06-01

    Fine needle aspiration biopsy (FNAB) plays a crucial role in the diagnosis of thyroid nodules and enables the number of surgical operations to be reduced. Theoretically, FNAB should be carried out on all nodules, though currently only those displaying certain characteristics are biopsied. Indeed, to perform FNAB on all nodules may be regarded as an excess of zeal. Therefore, it seems advisable that the endocrinologist should be able to confirm on the spot the necessity and utility of FNAB. We evaluated on a sample of 263 consecutive requests (209 female, 57 male; age 56.7+/-13.7 years) for FNAB in 2004: 1) the appropriateness of the investigation, 2) expected efficacy, 3) practical efficacy, 4) efficiency. FNAB was performed under echo-guidance in accordance with the standard technique. In 50%, 36%, 6%, 3%, 2% and 1% of cases, the echographic diagnosis was of MNG, UNG, pseudo-nodular lesion in ATD, lymph-node, neck cyst, suspected parathyroid lesion and tumefaction of the salivary glands, respectively. A pre-FNAB clinical risk score was assigned to each case on the basis of clinical and echographic data, with a maximum possible score of 11. The results of FNAB were subdivided into 5 categories according to the criteria of the BTA (Thy1-Thy5). After FNAB, a decisional category was assigned, ranging from ''observation'' to ''surgery''; this was subsequently (7-18 months) compared with the management strategy adopted by the attending physician. Information was gathered by means of telephone enquiry. 1) Appropriateness: on the basis of clinical and echographic findings, FNAB was not judged appropriate in 24% of cases because of either the lack of confirmation of a significant target (34%) or a low pre-FNAB risk score (range 0-2) (66%). The decisional category was ''observation'' in 87% of cases and ''further investigation'' in 13%. 2) Expected efficacy: FNAB was performed in 76% of cases. The biopsies (3%) performed on swollen lymph-nodes and extra-thyroid neck

  18. Improved laboratory resource utilization and patient care with the use of rapid on-site evaluation for endobronchial ultrasound fine-needle aspiration biopsy.

    Science.gov (United States)

    Collins, Brian T; Chen, Alexander C; Wang, Jeff F; Bernadt, Cory T; Sanati, Souzan

    2013-10-01

    Endobronchial ultrasound guided (EBUS) fine-needle aspiration (FNA) biopsy has become widely used to evaluate patients with thoracic abnormalities. Rapid on-site evaluation (ROSE) can provide the bronchoscopist with immediate evaluation findings during the procedure. This study examines EBUS FNA biopsy procedures with and without ROSE, and investigates the impact of ROSE service on the EBUS procedure and laboratory resource utilization. The cytopathology database at Washington University Medical Center, St. Louis, Missouri, was searched for EBUS FNA biopsy cases before and after introduction of ROSE service, and a matched cohort was collected. Reports were reviewed and pertinent data was collected, such as sites biopsied, ROSE performance, slide smears, cell blocks, and diagnostic categories. Statistical analysis of the results was performed. A matched case-controlled EBUS FNA cohort of 340 patients (680 total) for each category of non-ROSE and ROSE service were identified. There was a 33% reduction in the number of sites biopsied with ROSE. A total of 68% of patients with ROSE had just one biopsy site compared to only 36% of non-ROSE patients. There was a 30% decrease in total slides (mean, 5.27 slides) after the introduction of ROSE. All of these improvements were statistically significant. EBUS FNA biopsy ROSE service benefits patients by contributing to significantly fewer biopsies and improved utilization of health care resources. ROSE service results in substantially fewer total slides, which has a significant impact on the cytopathology laboratory work effort. The use of ROSE for EBUS FNA biopsy provides significant improvements in patient care and laboratory resource utilization. © 2013 American Cancer Society.

  19. High-resolution respirometry of fine-needle muscle biopsies in pre-manifest Huntington's disease expansion mutation carriers shows normal mitochondrial respiratory function.

    Directory of Open Access Journals (Sweden)

    Eva Buck

    Full Text Available Alterations in mitochondrial respiration are an important hallmark of Huntington's disease (HD, one of the most common monogenetic causes of neurodegeneration. The ubiquitous expression of the disease causing mutant huntingtin gene raises the prospect that mitochondrial respiratory deficits can be detected in skeletal muscle. While this tissue is readily accessible in humans, transgenic animal models offer the opportunity to cross-validate findings and allow for comparisons across organs, including the brain. The integrated respiratory chain function of the human vastus lateralis muscle was measured by high-resolution respirometry (HRR in freshly taken fine-needle biopsies from seven pre-manifest HD expansion mutation carriers and nine controls. The respiratory parameters were unaffected. For comparison skeletal muscle isolated from HD knock-in mice (HdhQ111 as well as a broader spectrum of tissues including cortex, liver and heart muscle were examined by HRR. Significant changes of mitochondrial respiration in the HdhQ knock-in mouse model were restricted to the liver and the cortex. Mitochondrial mass as quantified by mitochondrial DNA copy number and citrate synthase activity was stable in murine HD-model tissue compared to control. mRNA levels of key enzymes were determined to characterize mitochondrial metabolic pathways in HdhQ mice. We demonstrated the feasibility to perform high-resolution respirometry measurements from small human HD muscle biopsies. Furthermore, we conclude that alterations in respiratory parameters of pre-manifest human muscle biopsies are rather limited and mirrored by a similar absence of marked alterations in HdhQ skeletal muscle. In contrast, the HdhQ111 murine cortex and liver did show respiratory alterations highlighting the tissue specific nature of mutant huntingtin effects on respiration.

  20. Biomedical applications of capillary electrophoresis

    International Nuclear Information System (INIS)

    Kartsova, L A; Bessonova, E A

    2015-01-01

    The review deals with modern analytical approaches used in capillary electrophoresis for solving medical and biological problems: search for biomarkers of various diseases and rapid diagnosis based on characteristic profiles of biologically active compounds by capillary electrophoresis with mass spectrometric detection; monitoring of the residual drugs in biological fluids for evaluating the efficiency of drug therapy; testing of the enantiomeric purity of pharmaceutical products; the use of novel materials as components of stationary and pseudo-stationary phases in capillary electrophoresis and capillary electrochromatography to increase the selectivity of separation of components of complex matrices; and identification of various on-line preconcentration techniques to reduce the detection limits of biologically active analytes. A topical trend in capillary electrophoresis required in clinical practice, viz., the design of microfluidic systems, is discussed. The bibliography includes 173 references

  1. Scaling laws in centrifuge modelling for capillary rise in soils; Lois de similitude de l'ascension capillaire dans les sols en centrifugeuse

    Energy Technology Data Exchange (ETDEWEB)

    Rezzoug, A.; Konig, D.; Triantafyllidis, Th. [Ruhr Bochum Univ. (Germany)

    2000-07-01

    It appears to be possible to extend the application of geotechnical centrifuge modelling to environmental problems. In this paper, one aspect of similitude laws concerning the flow of water through soils is investigated. Within the Network of European Centrifuges of Environmental Geotechnic Research (NECER), several tests have been carried out to study similitude laws describing the capillary ascension in porous media under different levels of acceleration. The aim of this paper is to present the results obtained at Ruhr-Universitaet Bochum. A fine sand is used in the experiment. For the visualisation of capillary height in the soil sample, image processing is used. Different boundary conditions (constant water level or variable) have been investigated and discussed. A simple similitude law for capillary rise has been investigated and the kinetic phenomena has been measured at different g-levels. These experiments confirm, that capillary rise appears to be scaled by the factor N and time seems to be scaled by N{sup 2}. These results validate thus the possibility of using accelerated small-scale models of capillary phenomena in a centrifuge, and open the way to more complex investigations on flow and pollutant transports in unsaturated centrifuged soils. (authors)

  2. Experiences with a new breast localisation needle

    International Nuclear Information System (INIS)

    Hergan, K.; Amann, T.; Doringer, W.; Hollenstein, P.

    1990-01-01

    In view of the increasing number of biopsies of non-palpable lesions of the female breast we found an ideal localisation system in the Hawkins breast localisation needle. Localisation was successful without technical problems in 31 out of 34 patients. The special advantages of the needle are its stability in position and excellent manoeverability due to the construction of the needle. The very simple handling of the needle is an advantage not only for the radiologist but also for the surgeon. (orig.) [de

  3. Influence of local capillary trapping on containment system effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Steven [University Of Texas At Austin, Austin, TX (United States). Center for Petroleum and Geosystems Engineering

    2014-03-31

    implications for GCS. The first is that LCT can retain a significant fraction of the CO2 stored in a reservoir – above and beyond the residual saturation -- if the overlying seal were to fail. Thus frameworks for risk assessment should be extended to account for LCT. The second implication is that compared to pressure driven flow in reservoirs, CO2 migration and trapping behave in a qualitatively different manner in heterogeneous reservoirs when buoyancy is the dominant driving force for flow. Thus simulations of GCS that neglect capillary heterogeneity will fail to capture important features of the CO2 plume. While commercial reservoir simulation software can account for fine scale capillary heterogeneity, it has not been designed to work efficiently with such domains, and no simulators can handle fine-scale resolution throughout the reservoir. A possible way to upscale the migration and trapping is to apply an “effective residual saturation” to coarse-scale grids. While the extent of overall immobilization can be correlated in this way, all coarser grids failed to capture the distance traveled by the migrating CO2 for large gravity number. Thus it remains unclear how best to account for LCT in the routine simulation work-flow that will be needed for large-scale GCS. Alternatives meriting investigation include streamline methods, reduced-physics proxies (e.g. particle tracking), and biased invasion percolation algorithms, which are based on precisely the capillary heterogeneity essential for LCT.

  4. Capillary concentrators for synchrotron radiation beamlines

    International Nuclear Information System (INIS)

    Heald, S.M.; Brewe, D.L.; Kim, K.H.; Brown, F.C.; Barg, B.; Stern, E.A.

    1996-01-01

    Capillary concentrators condense x-rays by multiple reflections down a gradually tapering capillary. They can provide sub-micron beam spots, and are promising candidates for use in the next generation x-ray microprobe beamlines. The weak energy dependence of their properties make them especially useful for energy scanning applications such as micro-XAFS. This paper examines the potential performance of capillary optics for an x-ray microprobe, as well as some practical issues such as fabrication and alignment. Best performance at third generation sources requires long capillaries, and the authors have been using fiber optics techniques to fabricate capillaries up to one meter in length. The performance of shorter (less than about 0.5 m) capillaries has often been found to agree well with theoretical calculations, indicating the inner surface is a high quality x-ray reflector. These capillaries have been tested at the NSLS for imaging and micro-XAFS down to 2.6 microm resolution with excellent results. On an unfocused bend magnet line flux density approaching 10 6 ph/sec/microm 2 has been achieved. While nearly optimum profiles have been achieved for longer capillaries, the results have been disappointing, and alignment problems are suspected. The dramatic improvement in performance possible at third generation synchrotrons such as the APS is discussed along with improvements possible by using the capillaries in conjunction with coupling optics

  5. 21 CFR 868.5150 - Anesthesia conduction needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction needle. 868.5150 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5150 Anesthesia conduction needle. (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to...

  6. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  7. [Professor WU Zhongchao's experience of penetration needling].

    Science.gov (United States)

    Zhang, Ning; Wang, Bing; Zhou, Yu

    2016-08-12

    Professor WU Zhongchao has unique application of penetration needling in clinical treatment. Professor WU applies penetration needling along meridians, and the methods of penetration needling include self-meridian penetration, exterior-interior meridian penetration, identical-name meridian penetration, different meridian penetration. The meridian differentiation is performed according to different TCM syndromes, locations and natures of diseases and acupoint nature, so as to make a comprehensive assessment. The qi movement during acupuncture is focused. In addition, attention is paid on anatomy and long-needle penetration; the sequence and direction of acupuncture is essential, and the reinforcing and reducing methods have great originality, presented with holding, waiting, pressing and vibrating. Based on classical acupoint, the acupoint of penetration needling is flexible, forming unique combination of acupoints.

  8. Fine pitch thermosonic wire bonding: analysis of state-of-the-art manufacturing capability

    Science.gov (United States)

    Cavasin, Daniel

    1995-09-01

    A comprehensive process characterization was performed at the Motorola plastic package assembly site in Selangor, Malaysia, to document the current fine pitch wire bond process capability, using state-of-the-art equipment, in an actual manufacturing environment. Two machines, representing the latest technology from two separate manufacturers, were operated one shift per day for five days, bonding a 132 lead Plastic Quad Flat Pack. Using a test device specifically designed for fine pitch wire bonding, the bonding programs were alternated between 107 micrometers and 92 micrometers pad pitch, running each pitch for a total of 1600 units per machine. Wire, capillary type, and related materials were standardized and commercially available. A video metrology measurement system, with a demonstrated six sigma repeatability band width of 0.51 micrometers , was utilized to measure the bonded units for bond dimensions and placement. Standard Quality Assurance (QA) metrics were also performed. Results indicate that state-of-the-art thermosonic wire bonding can achieve acceptable assembly yields at these fine pad pitches.

  9. Capillary pumped loop body heat exchanger

    Science.gov (United States)

    Swanson, Theodore D. (Inventor); Wren, deceased, Paul (Inventor)

    1998-01-01

    A capillary pumped loop for transferring heat from one body part to another body part, the capillary pumped loop comprising a capillary evaporator for vaporizing a liquid refrigerant by absorbing heat from a warm body part, a condenser for turning a vaporized refrigerant into a liquid by transferring heat from the vaporized liquid to a cool body part, a first tube section connecting an output port of the capillary evaporator to an input of the condenser, and a second tube section connecting an output of the condenser to an input port of the capillary evaporator. A wick may be provided within the condenser. A pump may be provided between the second tube section and the input port of the capillary evaporator. Additionally, an esternal heat source or heat sink may be utilized.

  10. Management implications from routine needle biopsy of hyperfunctioning thyroid nodules.

    Science.gov (United States)

    Walfish, P G; Strawbridge, H T; Rosen, I B

    1985-12-01

    To evaluate the diagnostic and treatment consequences of using a routine needle biopsy procedure on all thyroid nodules without a radioisotopic scintigraphic study, 12 patients with documented hyperfunctioning thyroid nodules were retrospectively evaluated regarding the physical and cytologic observations obtained after a fine-needle (22 to 27-gauge) aspiration biopsy (FNB) procedure. Among the seven solid lesions, features of marked cellularity and nuclear pleomorphism were present in three and moderate sheets of epithelium in four raising the suspicion of underlying malignancy, while five mixed (cystic and solid) lesions were larger than 3 cm, hemorrhagic, and recurrent, with two having detectable sheets of epithelium. Evidence for concomitant lymphocytic thyroiditis was seen in five of 12 (42%) patients, and nine had positive serum antithyroid antibody titers as well. In conclusion, total reliance on FNB without scintigraphy could lead to operations on hyperfunctioning thyroid adenomas for suspected malignancy, of whom the vast majority would be benign, and could expose some unprepared patients with thyrotoxicosis to surgical morbidity. Routine thyroid hormone suppression therapy for apparently benign inflammatory or cystic degenerative lesions could also induce hyperthyroidism in patients with hyperfunctional or autonomous (nonsuppressible) nodules. When using an initial FNB approach, the need for thyroid function studies and scintigraphy before undertaking surgery or thyroid hormone feeding, as well as the consequences of omitting such studies, should be considered.

  11. Effect of bidirectional rotation of an acupuncture needle at LI10 on acupuncture needle sensation and experimentally-induced contact heat pain in healthy human volunteers.

    Science.gov (United States)

    Benham, Alex; Johnson, Mark I

    2014-06-01

    There is insufficient evidence of a relationship between acupuncture needle sensations (de qi) and hypoalgesia. The aim of this study was to investigate the effects of bidirectional needle rotation at LI10 on acupuncture needle sensations and heat pain thresholds. Twenty-two healthy participants received one acupuncture needle at LI10 with bidirectional rotation of the needle in one experimental session and one acupuncture needle at LI10 with mock rotation in a separate session, in a randomised order. Measurements of heat pain thresholds were taken before needle insertion, during needle retention and 15 min after needle removal. At each measurement time point, participants rated needle sensations using the Massachusetts Acupuncture Sensation Scale (MASS) and a visual analogue scale (VAS) of overall intensity of needle sensation. Bidirectional needle rotation produced significantly higher scores for VAS, MASStotal, MASSpain and MASSsensation compared with mock rotation (all psensation and change in pain threshold after needling was only found when data from mock and rotation interventions were combined. Needle rotation increases the magnitude of hypoalgesia. There is tentative evidence that needle sensation may be associated with the amount of change in pain threshold. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  13. Pulsed high energy synthesis of fine metal powders

    Science.gov (United States)

    Witherspoon, F. Douglas (Inventor); Massey, Dennis W. (Inventor)

    1999-01-01

    Repetitively pulsed plasma jets generated by a capillary arc discharge at high stagnation pressure (>15,000 psi) and high temperature (>10,000 K) are utilized to produce 0.1-10 .mu.m sized metal powders and decrease cost of production. The plasma jets impact and atomize melt materials to form the fine powders. The melt can originate from a conventional melt stream or from a pulsed arc between two electrodes. Gas streams used in conventional gas atomization are replaced with much higher momentum flux plasma jets. Delivering strong incident shocks aids in primary disintegration of the molten material. A series of short duration, high pressure plasma pulses fragment the molten material. The pulses introduce sharp velocity gradients in the molten material which disintegrates into fine particles. The plasma pulses have peak pressures of approximately one kilobar. The high pressures improve the efficiency of disintegration. High gas flow velocities and pressures are achieved without reduction in gas density. Repetitively pulsed plasma jets will produce powders with lower mean size and narrower size distribution than conventional atomization techniques.

  14. Capillary optics for radiation focusing

    International Nuclear Information System (INIS)

    Peurrung, A.J.; Reeder, P.L.; Bliss, M.; Craig, R.A.; Lepel, E.A.; Stromswold, D.C.; Stoffels, J.; Sunberg, D.S.; Tenny, H.

    1996-11-01

    Capillary lens technology may ultimately bring benefits to neutron and x-ray-based science like conventional lenses with visible light. Although the technology is not yet 10 years old, these lenses have already had a significant impact in engineering, science, and medicine. Capillary lenses are advantageous when it is desirable to increase the radiation flux at a location without regard to its angular divergence. PNNL has worked to improve the technology in several ways. A single, optimally tapered capillary was manufactured, which allows intensity gains of a factor of 270 for an initially parallel, incident x-ray beam. Feasibility of constructing neutron lenses using 58 Ni (particularly effective at reflecting neutrons) has been explored. Three applications for capillary optics have been identified and studied: neutron telescope, Gandolphi x-ray diffractometry, and neutron radiotherapy. A brief guide is given for determining which potential applications are likely to be helped by capillary optics

  15. Capillary waves of compressible fluids

    International Nuclear Information System (INIS)

    Falk, Kerstin; Mecke, Klaus

    2011-01-01

    The interplay of thermal noise and molecular forces is responsible for surprising features of liquids on sub-micrometer lengths-in particular at interfaces. Not only does the surface tension depend on the size of an applied distortion and nanoscopic thin liquid films dewet faster than would be expected from hydrodynamics, but also the dispersion relation of capillary waves differ at the nanoscale from the familiar macroscopic behavior. Starting with the stochastic Navier-Stokes equation we study the coupling of capillary waves to acoustic surface waves which is possible in compressible fluids. We find propagating 'acoustic-capillary waves' at nanometer wavelengths where in incompressible fluids capillary waves are overdamped.

  16. Observations of needle-tissue interactions

    NARCIS (Netherlands)

    Misra, Sarthak; Reed, Kyle B.; Ramesh, K.T.; Okamura, Allison M.

    2009-01-01

    Needles with asymmetric bevel tips naturally bend when they are inserted into soft tissue. In this study, we present an analytical model for the loads developed at the bevel tip during needle-tissue interaction. The model calculates the loads based on the geometry of the bevel edge and gel material

  17. Radio-frequency ablation in patients with malignant hepatic tumor and experimental model: comparison of expandable needle and water-cooled needle

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Yong Ju; Jeong, Yong Yeon; Kim, Jeong; Yim, Nam yeol; Kang, Heoung Keun [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of); Kim, Eun Ha; Yoon, Kwon Ha [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of); Ko, Seog Wan [School of Medicine, Chonbuk National Univ., Jeonju (Korea, Republic of)

    2004-12-01

    The purpose of this study was to compare the shape and volume of the radio-frequency induced lesions produced by two commercially available radio-frequency ablation (RFA) systems, the expandable and cooled-tip needles, in clinical patients and an experimental model. A twelve-array anchor expandable needle electrode and a single cooled-tip needle electrode were used to treat hepatic tumors with a single session in 23 patients (20 hepatocellular carcinomas and 3 hepatic metastases) and fourteen patients (10 hepatocellular carcinomas and 4 hepatic metastases), respectively. Twenty RFA induced lesions were created with each system in 10 explanted bovine livers. The shape of the RFA induced lesions were divided into oval lesions along or perpendicular to the axis of the electrode and spherical lesions, and we then calculated the volumes of the RFA induced lesions. Fourteen (61%) lesions of the 23 patients treated with the expandable system were oval perpendicular to the axis of the electrode and nine (39%) of the lesions were spherical. All the lesions (100%) of the 14 patients treated with the cooled-tip needle were ovaI along the axis of the electrode. In the ex vivo bovine livers, the shape of the all RFA induced lesions was oval perpendicular to the axis of the electrode for the expandable needle, and oval along the axis of the electrode for the cooled-tip needle. The mean diameter and volume of the RFA induced lesions in the patients were 3.35{+-}0.56 cm and 19.9{+-}6.53 cm{sup 3}, respectively, for the expandable needle and 3.58{+-}0.78 cm and 23.19{+-}5.27 cm{sup 3}, respectively, for the cooled-tip needle. In the ex vivo model, the mean diameter and volume of RFA induced lesions were 3.41{+-}0.59 cm and 26.59{+-}8.02 cm{sup 3}, respectively, for the expandable needle, and 4.04{+-}0.65 cm and 33.82{+-}6.16 cm{sup 3}, respectively, for the cooled-tip needle (p <0.05). These results indicate that the shape of RFA induced lesions with the expandable needle were oval

  18. Percutaneous Ethanol Injection of Unresectable Medium-to-Large-Sized Hepatomas Using a Multipronged Needle: Efficacy and Safety

    International Nuclear Information System (INIS)

    Ho, C.S.; Kachura, J.R.; Gallinger, S.; Grant, D.; Greig, P.; McGilvray, I.; Knox, J.; Sherman, M.; Wong, F.; Wong, D.

    2007-01-01

    Fine needles with an end hole or multiple side holes have traditionally been used for percutaneous ethanol injection (PEI) of hepatomas. This study retrospectively evaluates the safety and efficacy of PEI of unresectable medium-to-large (3.5-9 cm) hepatomas using a multipronged needle and with conscious sedation. Twelve patients, eight men and four women (age 51-77 years; mean: 69) received PEI for hepatomas, mostly subcapsular or exophytic in location with average tumor size of 5.6 cm (range: 3.5-9.0 cm). Patients were consciously sedated and an 18G retractable multipronged needle (Quadrafuse needle; Rex Medical, Philadelphia, PA) was used for injection under real-time ultrasound guidance. By varying the length of the prongs and rotating the needle, the alcohol was widely distributed within the tumor. The progress of ablation was monitored by contrast-enhanced ultrasound, computed tomography (CT) or magnetic resonance imaging (MRI) after each weekly injection and within a month after the final (third) injection and 3 months thereafter. An average total of 63 mL (range: 20-154 ml) of alcohol was injected per patient in an average of 2.3 sessions. Contrast-enhanced CT, ultrasound, or MRI was used to determine the degree of necrosis. Complete necrosis was noted in eight patients (67%), near-complete necrosis (90-99%) in two (16.7%), and partial success (50-89%) in two (16.7%). Follow-up in the first 9 months showed local recurrence in two patients and new lesions in another. There was no mortality. One patient developed renal failure, liver failure, and localized perforation of the stomach. He responded to medical treatment and surgery was not required for the perforation. One patient had severe postprocedural abdominal pain and fever, and another had transient hyperbilirubinemia; both recovered with conservative treatment. PEI with a multipronged needle is a new, safe, and efficacious method in treating medium-to-large-sized hepatocellular carcinoma under conscious

  19. Fluid Delivery System For Capillary Electrophoretic Applications.

    Science.gov (United States)

    Li, Qingbo; Liu, Changsheng; Kane, Thomas E.; Kernan, John R.; Sonnenschein, Bernard; Sharer, Michael V.

    2002-04-23

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  20. Monoliths in capillary electrochromatography and capillary liquid chromatography in conjunction with mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Rantamäki, A. H.; Duša, Filip; Wiedmer, S. K.

    2016-01-01

    Roč. 37, 7-8 (2016), s. 880-912 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : capillary electrochromatography * capillary liquid chromatography * mass spec- trometry * monolithic columns Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.744, year: 2016

  1. A Chip-Capillary Hybrid Device for Automated Transfer of Sample Pre-Separated by Capillary Isoelectric Focusing to Parallel Capillary Gel Electrophoresis for Two-Dimensional Protein Separation

    Science.gov (United States)

    Lu, Joann J.; Wang, Shili; Li, Guanbin; Wang, Wei; Pu, Qiaosheng; Liu, Shaorong

    2012-01-01

    In this report, we introduce a chip-capillary hybrid device to integrate capillary isoelectric focusing (CIEF) with parallel capillary sodium dodecyl sulfate – polyacrylamide gel electrophoresis (SDS-PAGE) or capillary gel electrophoresis (CGE) toward automating two-dimensional (2D) protein separations. The hybrid device consists of three chips that are butted together. The middle chip can be moved between two positions to re-route the fluidic paths, which enables the performance of CIEF and injection of proteins partially resolved by CIEF to CGE capillaries for parallel CGE separations in a continuous and automated fashion. Capillaries are attached to the other two chips to facilitate CIEF and CGE separations and to extend the effective lengths of CGE columns. Specifically, we illustrate the working principle of the hybrid device, develop protocols for producing and preparing the hybrid device, and demonstrate the feasibility of using this hybrid device for automated injection of CIEF-separated sample to parallel CGE for 2D protein separations. Potentials and problems associated with the hybrid device are also discussed. PMID:22830584

  2. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  3. Western blotting using capillary electrophoresis.

    Science.gov (United States)

    Anderson, Gwendolyn J; M Cipolla, Cynthia; Kennedy, Robert T

    2011-02-15

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein adsorption. Although discrete protein zones could be detected, bands were broadened by ∼1.7-fold by transfer to membrane. A complete Western blot for lysozyme was completed in about one hour with 50 pg mass detection limit from low microgram per milliliter samples. These results demonstrate substantial reduction in time requirements and improvement in mass sensitivity compared to conventional Western blots. Western blotting using capillary electrophoresis shows promise to analyze low volume samples with reduced reagents and time, while retaining the information content of a typical Western blot.

  4. Nasal Lobular Capillary Hemangioma

    Directory of Open Access Journals (Sweden)

    Prashant Patil

    2013-01-01

    Full Text Available Nasal lobular capillary hemangioma is a rare benign tumor of the paranasal sinuses. This lesion is believed to grow rapidly in size over time. The exact etiopathogenesis is still a dilemma. We discuss a case of nasal lobular capillary hemangioma presenting with a history of epistaxis. Contrast enhanced computed tomography of paranasal sinuses revealed an intensely enhancing soft-tissue mass in the left nasal cavity and left middle and inferior meati with no obvious bony remodeling or destruction. We present imaging and pathologic features of nasal lobular capillary hemangioma and differentiate it from other entities like nasal angiofibroma.

  5. Pine needle abortion biomarker detected in bovine fetal fluids

    Science.gov (United States)

    Pine needle abortion is a naturally occurring condition in free-range cattle caused by the consumption of pine needles from select species of cypress, juniper, pine, and spruce trees. Confirmatory diagnosis of pine needle abortion has previously relied on a combined case history of pine needle cons...

  6. Use of tapered Pyrex capillary tubes to increase the mechanical stability of multiwall carbon nanotubes field emitters

    Science.gov (United States)

    Mousa, M. S.; Bani Ali, E. S.; Hagmann, M. J.

    2018-02-01

    In this study, NanocylTM NC 7000 Thin Multiwall Carbon Nanotubes (MWCNTs) were used with a high aspect ratio (>150) made by the process of catalytic chemical vapor deposition (CCVD). The field emitter tips were prepared by inserting these MWCT into fine glass capillary tubes that were pulled at high temperatures and then cut. Measurements were carried out under ultra-high vacuum (UHV) conditions with a base pressure of 10-9 mbar. The data show the effects of initial conditioning of MWCNT and hysteresis. Compression of the MWCNT by the capillary tubes appears to provide adequate mechanical support without requiring the use of a low-melting point electrically-conductive binder as has been used previously. Emission currents in excess of 1 μA were obtained so this technique shows promise as a reliable, stable, powerful electron source.

  7. Her-2 neu (Cerb-B2) expression in fine needle aspiration samples of breast carcinoma: A pilot study comparing FISH, CISH and immunocytochemistry.

    Science.gov (United States)

    Kapila, Kusum; Al-Awadhi, S; Francis, Im

    2011-04-01

    Breast cancers with Her-2 neu gene amplification are recognized as important markers for aggressive disease and targets which respond to therapy with trastuzumab. Her-2 neu testing on histological sections is routinely performed to select patients who may benefit from anti- Her-2 neu therapy. Few reports are available which document Her-2 neu status on fine needle aspirates (FNA). This pilot study is to document expression of Her-2 neu (Cerb-B2) on cytospin smears from FNA of patients with breast carcinoma. Twenty samples of FNA already collected for diagnostic purposes from patients with primary breast carcinoma were studied for demonstration of Her-2 neu expression by immunohistochemistry (IHC), Fluorescent in-situ hybridization (FISH) and chromogenic in-situ hybridization (CISH) on cytospin smears from FNA. Their expression was compared with tissue sections where possible. Good correlation was observed between Her-2 neu protein expression and gene amplification in cytospin smears. Three of five (60%) breast carcinomas cases with 2+ and 3+ staining on IHC showed gene amplification by FISH and CISH. Three of 7 (43%) and 5 of 7 (71%) cases negative/1+ staining on IHC did not show gene amplification by FISH and CISH respectively. Tissue sections from 10 cases with 2+ and 3+ staining for Her2neu by IHC showed gene amplification in 8 cases. Demonstration of Her-2 neu by IHC, FISH or CISH in FNA is possible and may play a role in the management of patients with advanced breast cancer or those cases where surgical resection is not advisable.

  8. Histopathologic Findings Related to the Indeterminate or Inadequate Results of Fine-Needle Aspiration Biopsy and Correlation with Ultrasonographic Findings in Papillary Thyroid Carcinomas

    International Nuclear Information System (INIS)

    Jung, So Lyung; Jung, Chan Kwon; Kim, Sung Hun; Kang, Bong Joo; Ahn, Kook Jin; Kim, Bum Soo; Ahn, Myeong Im; Im, Dong Jun; Bae, Ja Sung; Chung, Soo Kyo

    2010-01-01

    To determine histopathologic findings related to the indeterminate or inadequate result of fine-needle aspiration biopsy (FNAB) in papillary thyroid carcinomas (PTCs) and to correlate histopathological findings with ultrasonographic features of tumors. We retrospectively reviewed the medical records of FNAB, histopathologic characteristics, and sonographic findings of the solid portion of 95 PTCs in 95 patients. All cases were pathologically confirmed by surgery. Histopathologic characteristics were analyzed for tumor distribution, microcystic changes, fibrosis, and tumor component. We assumed several histopathologic conditions to be the cause of indeterminate or inadequate results of FNAB, including: 1) an uneven tumor distribution, 2) > 30% microcystic changes, 3) > 30% fibrosis, and 4) < 30% tumor component. Ultrasonographic findings of each PTC were evaluated for echotexture (homogeneous or heterogeneous), echogenicity (markedly hypoechoic, hypoechoic, isoechoic, or hyperechoic), and volume of the nodule. We correlated histopathologic characteristics of the PTC with results of the FNAB and ultrasonographic findings. From 95 FNABs, 71 cases (74%) were confirmed with malignancy or suspicious malignancy (PTCs), 21 (22%) had indeterminate results (atypical cells), and three (4%) were negative for malignancy. None of the assumed variables influenced the diagnostic accuracy of FNAB. Tumor distribution and fibrosis were statistically correlated with ultrasonographic findings of the PTCs (p < 0.05). Uneven tumor distribution was related with small tumor volume, and fibrosis over 30% was correlated with homogeneous echotexture, markedly hypoechoic and hypoechoic echogenicity, and small tumor volume (p < 0.05). No histopathologic component was found to correlate with improper results of FNAB in PTCs. In contrast, two histopathologic characteristics, uneven distribution and fibrosis, were correlated with ultrasonographic findings

  9. New helium sniffing device for locating very fine leaks

    International Nuclear Information System (INIS)

    Murakami, Y.; Shimomura, Y.; Abe, T.; Obara, K.

    1984-01-01

    A new helium sniffing method for leak checking large vacuum vessels is described. The low sensitivity problem of the conventional helium sniffing method has been overcome by increasing the gas draw rate from around leaks into the detector up to about 0.1 Pa m 3 /s. The devised system consists of a flexible stainless steel capillary tube 0.6 mm i.d. and 10 m long, a sorption pump using molecular sieve, and a helium leak detector in series. This method is particularly useful for locating very fine leaks down to 10 -11 Pa m 3 /s. Relevant theoretical considerations and experimental results are presented

  10. Fine-needle aspirates CYFRA 21-1 is a useful tumor marker for detecting axillary lymph node metastasis in breast cancer patients.

    Directory of Open Access Journals (Sweden)

    Jung Hyun Yoon

    Full Text Available INTRODUCTION: To assess whether the value of CYFRA21-1 in the aspirates of ultrasonography-guided fine-needle aspiration biopsy (US-FNAB can contribute to improving the performances of US-FNAB in the diagnosis of axillary lymph node (LN metastasis in breast cancer patients. METHODS: US-FNAB was performed in 156 axillary LNs in 152 breast cancer patients (mean age: 51.4 years, range: 17-92 years. Concentrations of CYFRA21-1 were measured from washouts of the syringe used during US-FNAB. Tumor marker concentrations, US-FNAB, intraoperative sentinel node biopsy (SNB, and surgical pathology results were reviewed and analyzed. For comparison, the values of CEA and CA15-3 were also measured from washouts. RESULTS: Among the 156 LNs, 75 (48.1% were benign, and 81 (51.9% were metastases. Mean concentrations of CYFRA21-1 were significantly higher in metastasis compared to benign LNs (P<0.001. US-FNAB combined to CYFRA21-1 showed significantly higher sensitivity, NPV, and accuracy compared to US-FNAB alone (all values P<0.05. All diagnostic indices of US-FNAB combined to CYFRA21-1 were significantly higher compared to US-FNAB combined with CEA or CA15-3 (all P<0.001. Of the 28 metastatic LNs which showed metastasis on SNB, CYFRA21-1 showed higher positive rate of 75.0% (CEA or CA15-3∶60.7%, P = 0.076. CONCLUSION: Measuring CYFRA 21-1 concentrations from US-FNAB aspirates improves sensitivity, NPV, and accuracy of US-FNAB alone, and may contribute to reducing up to 75.0% of unnecessary intraoperative SNB. Compared to CEA or CA15-3, CYFRA21-1 shows significantly higher performances when combined to US-FNAB in the preoperative diagnosis of LN metastasis in breast cancer patients.

  11. Fine-Needle Aspiration Biopsy of the Lymph Node: A Novel Tool for the Monitoring of Immune Responses after Skin Antigen Delivery.

    Science.gov (United States)

    Tatovic, Danijela; Young, Philippa; Kochba, Efrat; Levin, Yotam; Wong, F Susan; Dayan, Colin M

    2015-07-01

    Assessment of immune responses in lymph nodes (LNs) is routine in animals, but rarely done in humans. We have applied minimally invasive ultrasound-guided fine-needle aspiration of the LN to a before-and-after study of the immune response to intradermally delivered Ag in healthy volunteers (n = 25). By comparison with PBMCs from the same individual, LN cells (LNCs) were characterized by reduced numbers of effector memory cells, especially CD8(+) TEMRA cells (3.37 ± 1.93 in LNCs versus 22.53 ± 7.65 in PBMCs; p = 0.01) and a marked increased in CD69 expression (27.67 ± 7.49 versus 3.49 ± 2.62%, LNCs and PBMCs, respectively; p < 0.0001). At baseline, there was a striking absence of IFN-γ ELISPOT responses to recall Ags (purified protein derivative, Tetanus toxoid, or flu/EBV/CMV viral mix) in LN, despite strong responses in the peripheral blood. However, 48 h after tuberculin purified protein derivative administration in the ipsilateral forearm resulting in a positive skin reaction, a clear increase in IFN-γ ELISPOT counts was seen in the draining LN but not in PBMCs. This response was lost by 5 d. These data suggest that the low levels of effector memory cells in the LN may explain the low background of baseline ELISPOT responses in LNs as compared with PBMCs, and the appearance of a response after 48 h is likely to represent migration of effector memory cells from the skin to the LN. Hence, it appears that the combination of intradermal Ag administration and draining LN sampling can be used as a sensitive method to probe the effector memory T cell repertoire in the skin. Copyright © 2015 by The American Association of Immunologists, Inc.

  12. Clinical utility of routine pre-operative axillary ultrasound and fine needle aspiration cytology in patient selection for sentinel lymph node biopsy.

    Science.gov (United States)

    Rattay, T; Muttalib, M; Khalifa, E; Duncan, A; Parker, S J

    2012-04-01

    In patients with operable breast cancer, pre-operative evaluation of the axilla may be of use in the selection of appropriate axillary surgery. Pre-operative axillary ultrasound (US) and fine needle aspiration cytology (FNAC) assessments have become routine practice in many breast units, although the evidence base is still gathering. This study assessed the clinical utility of US+/-FNAC in patient selection for either axillary node clearance (ANC) or sentinel lymph node biopsy (SLNB) in patients undergoing surgery for operable breast cancer. Over a two-year period, 348 patients with a clinically negative axilla underwent axillary US. 67 patients with suspicious nodes on US also underwent FNAC. The sensitivity and specificity of axillary investigations to determine nodal involvement were 56% (confidence interval: 47-64%) and 90% (84-93%) for US alone, and 76% (61-87%) and 100% (65-100%) for FNAC combined with US, respectively. With a positive US, the post-test probability was 78%. A negative US carried a post-test probability of 25%. When FNAC was positive, the post-test probability was greater than unity. A negative FNAC yielded a post-test probability of 52%. All patients with positive FNAC and most patients with suspicious US were listed for axillary node clearance (ANC) after consideration at the multi-disciplinary team (MDT) meeting. With pre-operative axillary US+/-FNAC, 20% of patients were saved a potential second axillary procedure, facilitating a reduction in the overall re-operation rate to 12%. In this study, a positive pre-operative US+/-FNAC directs patients towards ANC. When the result is negative, other clinico-pathological factors need to be taken into account in the selection of the appropriate axillary procedure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Diagnostic value of sonography, ultrasound-guided fine-needle aspiration cytology, and diffusion-weighted MRI in the characterization of cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)], E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kaserer, Klaus [Department of Pathology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Scheuba, Christian [Department of Surgery, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Ringl, Helmut; Weber, Michael; Czerny, Christian; Herneth, Andreas M. [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-03-15

    Introduction: The purpose of this prospective study was to assess the diagnostic value of different modalities for the characterization of cold thyroid nodules. Methods: In 35 patients with cold nodules, thyroid carcinoma was suspected on scintigraphy. These patients were prospectively investigated with sonography, ultrasound-guided fine-needle aspiration (USgFNA), and quantitative diffusion-weighted imaging magnetic resonance imaging (DWI) (navigated echo-planar imaging; maximum b-value 800 s/mm{sup 2}) prior to surgery. The sonographic findings, USgFNA cytology, and the apparent diffusion coefficient (ADC) values of DWI were correlated with the postoperative histology of benign and malignant lesions. Statistical analysis was performed with the Kruskal-Wallis test and the Fisher's exact test. P < .05 denoted statistical significance. Results: The accuracy of sonography and USgFNA was 64% and 68.8%, respectively. The sensitivity was 86.7% and 80%, respectively. Specificity was only 57.2% and 50%, respectively. The median ADC values for carcinoma and adenoma were 2.73 x 10{sup -3} mm{sup 2}/s and 1.93 x 10{sup -3} mm{sup 2}/s, respectively (P < .001). There was no significant difference between the median ADC value for Hashimoto thyroiditis (3.46 x 10{sup -3} mm{sup 2}/s) and carcinoma. An ADC value of 2.25 x 10{sup -3} mm{sup 2}/s or higher was proven to be the cut-off value for differentiating between benign and malignant cold thyroid nodules, with an accuracy of 88%, a sensitivity of 85%, and a specificity of 100%. Conclusions: These results show that quantitative DWI is a more reliable diagnostic method for differentiation between benign and malignant thyroid lesions than sonography or USgFNA. However, further studies including a larger study population are necessary to confirm our study results.

  14. Progression of Diabetic Capillary Occlusion: A Model.

    Directory of Open Access Journals (Sweden)

    Xiao Fu

    2016-06-01

    Full Text Available An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions.

  15. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  16. Reliable and valid assessment of competence in endoscopic ultrasonography and fine-needle aspiration for mediastinal staging of non-small cell lung cancer.

    Science.gov (United States)

    Konge, L; Vilmann, P; Clementsen, P; Annema, J T; Ringsted, C

    2012-10-01

    Fine-needle aspiration (FNA) guided by endoscopic ultrasonography (EUS) is important in mediastinal staging of non-small cell lung cancer (NSCLC). Training standards and implementation strategies of this technique are currently under discussion. The aim of this study was to explore the reliability and validity of a newly developed EUS Assessment Tool (EUSAT) designed to measure competence in EUS - FNA for mediastinal staging of NSCLC. A total of 30 patients with proven or suspected NSCLC underwent EUS - FNA for mediastinal staging by three trainees and three experienced physicians. Their performances were assessed prospectively by three experts in EUS under direct observation and again 2 months later in a blinded fashion using digital video-recordings. Based on the assessments, intra-rater reliability, inter-rater reliability, and construct validity were explored. The intra-rater reliability was good (Cronbach's α = 0.80), but comparison of results based on direct observations and blinded video-recordings indicated a significant bias favoring consultants (P = 0.022). Inter-rater reliability was very good (Cronbach's α = 0.93). However, one rater assessing five procedures or two raters each assessing four procedures were necessary to secure a generalizability coefficient of 0.80. The assessment tool demonstrated construct validity by discriminating between trainees and experienced physicians (P = 0.034). Competency in mediastinal staging of NSCLC using EUS and EUS - FNA can be assessed in a reliable and valid way using the EUSAT assessment tool. Measuring and defining competency and training requirements could improve EUS quality and benefit patient care. © Georg Thieme Verlag KG Stuttgart · New York.

  17. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  18. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtürk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean

    2012-01-01

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, δ. The candidate needle set consisted of 5000 needles, and a range of δ values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of δ values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer

  19. Capillary waves in slow motion

    International Nuclear Information System (INIS)

    Seydel, Tilo; Tolan, Metin; Press, Werner; Madsen, Anders; Gruebel, Gerhard

    2001-01-01

    Capillary wave dynamics on glycerol surfaces has been investigated by means of x-ray photon correlation spectroscopy performed at grazing angles. The measurements show that thermally activated capillary wave motion is slowed down exponentially when the sample is cooled below 273 K. This finding directly reflects the freezing of the surface waves. The wave-number dependence of the measured time constants is in quantitative agreement with theoretical predictions for overdamped capillary waves

  20. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  1. Migration of innumerable chronically retained acupuncture needles

    Directory of Open Access Journals (Sweden)

    Frances Lazarow, MD

    2017-09-01

    Full Text Available We present a case of a 50-year-old female with a 2-day history of back and abdominal pain who was discovered to have innumerable chronically retained acupuncture needles, which had migrated throughout her abdomen and pelvis. Although many of these needles were in precarious positions, including the epidural space, renal parenchyma, small bowel, and vasculature, there was no evidence for acute injury. We also briefly discuss evidence for the magnetic resonance imaging compatibility of acupuncture needles. Although a rare complication, given the high frequency of acupuncture therapy in the United States, physicians must be aware of the potential for retained and migrated needles.

  2. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  3. Comprehensive protein profiling by multiplexed capillary zone electrophoresis using cross-linked polyacrylamide coated capillaries.

    Science.gov (United States)

    Liu, Shaorong; Gao, Lin; Pu, Qiaosheng; Lu, Joann J; Wang, Xingjia

    2006-02-01

    We have recently developed a new process to create cross-linked polyacrylamide (CPA) coatings on capillary walls to suppress protein-wall interactions. Here, we demonstrate CPA-coated capillaries for high-efficiency (>2 x 10(6) plates per meter) protein separations by capillary zone electrophoresis (CZE). Because CPA virtually eliminates electroosmotic flow, positive and negative proteins cannot be analyzed in a single run. A "one-sample-two-separation" approach is developed to achieve a comprehensive protein analysis. High throughput is achieved through a multiplexed CZE system.

  4. Ion guiding and losses in insulator capillaries

    International Nuclear Information System (INIS)

    Juhasz, Z.; Sulik, B.; Vikor, Gy.; Biri, S.; Fekete, E.; Ivan, I.; Gall, F.; Toekesi, K.; Matefi-Tempfli, S.; Matefi-Tempfli, M.

    2007-01-01

    Complete text of publication follows. Not long ago it was discovered that insulating capillaries can guide slow ions, so that the ions avoid close contact with the capillary walls and preserve their initial charge state. This phenomenon did not only give a new puzzle for theoreticians but opened the way for new possible applications where ions are manipulated (deflected, focused and directed to different patterns on the irradiated media) with small capillary devices. The most important question for such applications is how large fraction of the ions can be guided to the desired direction. It is already known that the ion guiding is due to the charging up of the inner capillary walls by earlier ion impact events. In tilted capillaries one side of the capillary walls charges up. This deflects the later arriving ions, so that some of them pass through the capillaries nearly parallel with respect to their axes. The angle where the transmission drops to 1/e of the direct transmission at 0 deg is the guiding angle, which characterize the guiding ability. At 0 deg the ideal 100 percent transmission for the ions, which enter the capillaries, is reduced due to the mirror charge attraction and geometrical imperfections. These losses appear in the transmission for tilted capillaries with similar magnitude, since after the deflection region, which usually restricted to the close surroundings of the capillary openings, the guided ions pass through the rest of the capillaries as in non-tilted samples. In our experimental studies with Al 2 O 3 capillaries we found that around 90 percent of the incoming ions are lost. To understand these significant losses, the effects of the mirror charge attraction and geometrical imperfections have been calculated classically. The mirror charge potential was taken from.The model of the capillaries used in the calculations can be seen in Figure 1. The calculations have shown that the effects of mirror charge attraction and the angular

  5. DNA typing by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, N.

    1997-10-08

    Capillary electrophoresis is becoming more and more important in nucleic acid analysis including DNA sequencing, typing and disease gene measurements. This work summarized the background of DNA typing. The recent development of capillary electrophoresis was also discussed. The second part of the thesis showed the principle of DNA typing based on using the allelic ladder as the absolute standard ladder in capillary electrophoresis system. Future work will be focused on demonstrating DNA typing on multiplex loci and examples of disease diagnosis in the on-line format of PCR-CE. Also capillary array electrophoresis system should allow high throughput, fast speed DNA typing. Only the introduction and conclusions for this report are available here. A reprint was removed for separate processing.

  6. Bacterial surface layer proteins as a novel capillary coating material for capillary electrophoretic separations

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Gordaliza, Estefanía, E-mail: emorenog@ucm.es [Division of Analytical Biosciences, Leiden Academic Centre for Drug Research, Universiteit Leiden, Einsteinweg 55, 2300, RA, Leiden (Netherlands); Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Avda. Complutense s/n, 28040, Madrid (Spain); Stigter, Edwin C.A. [Division of Analytical Biosciences, Leiden Academic Centre for Drug Research, Universiteit Leiden, Einsteinweg 55, 2300, RA, Leiden (Netherlands); Department of Molecular Cancer Research, Universitair Medisch Centrum Utrecht, Wilhelmina Kinder Ziekenhuis, Lundlaan 6, 3584, EA Utrecht (Netherlands); Lindenburg, Petrus W.; Hankemeier, Thomas [Division of Analytical Biosciences, Leiden Academic Centre for Drug Research, Universiteit Leiden, Einsteinweg 55, 2300, RA, Leiden (Netherlands)

    2016-06-07

    A novel concept for stable coating in capillary electrophoresis, based on recrystallization of surface layer proteins on hydrophobized fused silica capillaries, was demonstrated. Surface layer protein A (SlpA) from Lactobacillus acidophilus bacteria was extracted, purified and used for coating pre-silanized glass substrates presenting different surface wettabilities (either hydrophobic or hydrophilic). Contact angle determination on SlpA-coated hydrophobic silica slides showed that the surfaces turned to hydrophilic after coating (53 ± 5°), due to a protein monolayer formation by protein-surface hydrophobic interactions. Visualization by atomic force microscopy demonstrated the presence of a SlpA layer on methylated silica slides displaying a surface roughness of 0.44 ± 0.02 nm. Additionally, a protein layer was visualized by fluorescence microscopy in methylated silica capillaries coated with SlpA and fluorescein isothiocyanate-labeled. The SlpA-coating showed an outstanding stability, even after treatment with 20 mM NaOH (pH 12.3). The electroosmotic flow in coated capillaries showed a partial suppression at pH 7.50 (3.8 ± 0.5 10{sup −9} m{sup 2} V{sup −1} s{sup −1}) when compared with unmodified fused silica (5.9 ± 0.1 10{sup −8} m{sup 2} V{sup −1} s{sup −1}). To demonstrate the potential of this novel coating, the SlpA-coated capillaries were applied for the first time for electrophoretic separation, and proved to be very suitable for the isotachophoretic separation of lipoproteins in human serum. The separations showed a high degree of repeatability (absolute migration times with 1.1–1.8% coefficient-of-variation (CV) within a day) and 2–3% CV inter-capillary reproducibility. The capillaries were stable for more than 100 runs at pH 9.40, and showed to be an exceptional alternative for challenging electrophoretic separations at long-term use. - Highlights: • New coating using recrystallized surface-layer proteins on

  7. Capillary Condensation in Confined Media

    OpenAIRE

    Charlaix, Elisabeth; Ciccotti, Matteo

    2009-01-01

    28 pages - To appear in 2010 in the Handbook of Nanophysics - Vol 1 - Edited by Klaus Sattler - CRC Press; We review here the physics of capillary condensation of liquids in confined media, with a special regard to the application in nanotechnologies. The thermodynamics of capillary condensation and thin film adsorption are first exposed along with all the relevant notions. The focus is then shifted to the modelling of capillary forces, to their measurements techniques (including SFA, AFM and...

  8. Capillary-Condenser-Pumped Heat-Transfer Loop

    Science.gov (United States)

    Silverstein, Calvin C.

    1989-01-01

    Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

  9. Investigation of environmental pollution with pine needles by NAA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Yong; Yoon, Yoon Yeol; Yang, Myung Kwon; Shim, Sang Kwon; Seo, Bum Kyoung [Korea Inst. of Geosience and Mineral Resources, Environmental Geology Division, Daejeon (Korea); Chung, Yong Sam [Korea Atomic Energy Research Inst., HANARO Center, Daejeon (Japan)

    2002-04-01

    NAA was studied to precision analysis of metallic elements in pine needle. The pine needle was investigated whether it can be feasible or not as a bio-monitor. Only one year old needle was taken from three different regions of urban, suburban and rural area in four seasons. The needle sample was divided with two aliquots, and then one was cleaned and the other was not. Loss and contamination of analytes were cautiously minimized when the needle was sample and transferred from mountain to laboratory and prepared for NAA. Some elements such as As, Br, Ce, W, Zn have shown different characteristics with regions and seasons as well as surface cleaning. It is found that about twenty elements in pine needle could be simply analyzed by NAA and the pine needle could be suitable as a bio-monitor for the monitoring of environmental pollution in Korea. (author)

  10. Malignant-looking thyroid nodules with size reduction: Core needle biopsy results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ha Young; Baek, Jung Hwan; Ha, Eun Jun; Park, Jee Won; Lee, Jeong Hyun; Song, Dong Eun; Shong, Young Kee [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-08-15

    The aim of this study was to evaluate whether malignant-looking thyroid nodules with size reduction were malignant or not. From November 2010 to July 2011, we retrospectively enrolled 16 patients with 16 nodules (11 females and five males; mean age, 55 years) who underwent core needle biopsy (CNB), and whose thyroid nodules had malignant ultrasonographic (US) features, although they showed size reduction (>20% decrease in maximum diameter) during the follow-up period (mean, 37±27 months). The histologic findings of the CNB specimen were reviewed and correlated with the US findings. US studies were analyzed for their internal content, shape, margin, echogenicity, the presence of microcalcification and macrocalcification, inner isoechoic rim, and low-echoic halo. All nodules were confirmed as benign by CNB. Pathologic analysis was available for 12 CNB specimens. US imaging showed central hypoechogenicity or marked hypoechogenicity in all cases and a peripheral isoechoic rim in 15 nodules. US-pathologic correlation showed that the central hypoechoic area was primarily composed of fibrosis (12/12) and hemorrhage (8/12) and that the isoechoic rim was composed of follicular cells. In our study, the CNB results of all of the malignant-looking thyroid nodules with size reduction were benign and were primarily composed of internal fibrosis and hemorrhage. Understanding these US and pathologic features could prevent repeated fine-needle aspiration or unnecessary diagnostic surgery.

  11. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Capillary leak syndrome: etiologies, pathophysiology, and management.

    Science.gov (United States)

    Siddall, Eric; Khatri, Minesh; Radhakrishnan, Jai

    2017-07-01

    In various human diseases, an increase in capillary permeability to proteins leads to the loss of protein-rich fluid from the intravascular to the interstitial space. Although sepsis is the disease most commonly associated with this phenomenon, many other diseases can lead to a "sepsis-like" syndrome with manifestations of diffuse pitting edema, exudative serous cavity effusions, noncardiogenic pulmonary edema, hypotension, and, in some cases, hypovolemic shock with multiple-organ failure. The term capillary leak syndrome has been used to describe this constellation of disease manifestations associated with an increased capillary permeability to proteins. Diseases other than sepsis that can result in capillary leak syndrome include the idiopathic systemic capillary leak syndrome or Clarkson's disease, engraftment syndrome, differentiation syndrome, the ovarian hyperstimulation syndrome, hemophagocytic lymphohistiocytosis, viral hemorrhagic fevers, autoimmune diseases, snakebite envenomation, and ricin poisoning. Drugs including some interleukins, some monoclonal antibodies, and gemcitabine can also cause capillary leak syndrome. Acute kidney injury is commonly seen in all of these diseases. In addition to hypotension, cytokines are likely to be important in the pathophysiology of acute kidney injury in capillary leak syndrome. Fluid management is a critical part of the treatment of capillary leak syndrome; hypovolemia and hypotension can cause organ injury, whereas capillary leakage of administered fluid can worsen organ edema leading to progressive organ injury. The purpose of this article is to discuss the diseases other than sepsis that produce capillary leak and review their collective pathophysiology and treatment. Copyright © 2017 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  13. Electro-capillary effects in capillary filling dynamics of electrorheological fluids.

    Science.gov (United States)

    Dhar, Jayabrata; Ghosh, Uddipta; Chakraborty, Suman

    2015-09-21

    The flow of electrorheological fluids is characterized by an apparent increase in viscosity manifested by the yield stress property of the fluid, which is a function of the applied electric field and the concentration of the suspended solute phase within the dielectric medium. This property of electrorheological fluids generally hinders flow through a capillary if the imposed shear stress is lower than the induced yield stress. This results in a plug-like zone in the flow profile, thus giving the fluid Bingham plastic properties. In the present work, we study such influences of the yield stress on the capillary filling dynamics of an electrorheological fluid by employing a rheologically consistent reduced order formalism. One important feature of the theoretical formalism is its ability to address the intricate interplay between the surface tension and viscous forces, both of which depend sensitively on the electric field. Our analysis reveals that the progress of the capillary front is hindered at an intermediate temporal regime, which is attributable to the increase of the span of the plug-zone across the channel width with time. With a preliminary understanding on the cessation of the capillary front advancement due to the yield stress property of the electrorheological fluids, we further strive to achieve a basic comparison with an experimental study made earlier. Reasonable agreements with the reported data support our theoretical framework. Comprehensive scaling analysis brings further insight to our reported observations over various temporal regimes.

  14. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  15. Exploring needle anxiety among students attending a Nigerian ...

    African Journals Online (AJOL)

    Needle anxiety, a form of specific phobia refers to an intense fear of needles used for various medical procedures. It may result in the avoidance of such needle-involving procedures like intramuscular injections or vaccinations. About 4-8% of children and adolescents are said to generally suffer some form of anxiety.

  16. Microfluidic PMMA interfaces for rectangular glass capillaries

    International Nuclear Information System (INIS)

    Evander, Mikael; Tenje, Maria

    2014-01-01

    We present the design and fabrication of a polymeric capillary fluidic interface fabricated by micro-milling. The design enables the use of glass capillaries with any kind of cross-section in complex microfluidic setups. We demonstrate two different designs of the interface; a double-inlet interface for hydrodynamic focusing and a capillary interface with integrated pneumatic valves. Both capillary interfaces are presented together with examples of practical applications. This communication shows the design optimization and presents details of the fabrication process. The capillary interface opens up for the use of complex microfluidic systems in single-use glass capillaries. They also enable simple fabrication of glass/polymer hybrid devices that can be beneficial in many research fields where a pure polymer chip negatively affects the device's performance, e.g. acoustofluidics. (technical note)

  17. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  18. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  19. A complete soil hydraulic model accounting for capillary and adsorptive water retention, capillary and film conductivity, and hysteresis

    NARCIS (Netherlands)

    Sakai, Masaru; Van Genuchten, Martinus Th|info:eu-repo/dai/nl/31481518X; Alazba, A. A.; Setiawan, Budi Indra; Minasny, Budiman

    2015-01-01

    A soil hydraulic model that considers capillary hysteretic and adsorptive water retention as well as capillary and film conductivity covering the complete soil moisture range is presented. The model was obtained by incorporating the capillary hysteresis model of Parker and Lenhard into the hydraulic

  20. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  1. Immunoglobulin heavy and light chains and T-cell receptor beta and gamma chains PCR assessment on cytological samples. A study comparing FTA cards and cryopreserved lymph node fine-needle cytology.

    Science.gov (United States)

    Peluso, A L; Cozzolino, I; Bottiglieri, A; Lucchese, L; Di Crescenzo, R M; Langella, M; Selleri, C; Zeppa, P

    2017-06-01

    To evaluate and compare the DNA yield and quality extracted from lymph node fine needle cytology (FNC) samples stored on FTA cards to those cryopreserved, and to assess the immunoglobulin heavy and light chains (IGHK) and T-Cell receptor beta and gamma chains (TCRBG) PCR tests. DNA extractions were performed on FNC of 80 non-Hodgkin lymphomas (NHL), four myelomas and 56 benign reactive hyperplasias (BRH) cryopreserved and stored on FTA cards. The JAK2 gene was amplified to assess the DNA integrity and the IGHK/TCRBG clonality status was tested. IGHK monoclonality was found in 99% of B-cell NHL and 100% of myeloma. TCRBG monoclonality was found in 100% of T-cell NHL. TCRBG polyclonality was detected in 97% of B-cell NHL, 100% of myeloma and 96% of BRH. IGHK/TCRBG PCR data were confirmed by histological and/or follow-up controls. No differences were found in the DNA quality between cryopreservation and FTA cards storage methods. IGHK/TCRBG PCR of the lymphoproliferative process on FTA cards is comparable to those cryopreserved. FTA cards can be used to store lymph node FNC for further molecular investigations. © 2016 John Wiley & Sons Ltd.

  2. Quantification of nucleotides by ICPMS: coupling of ICPMS with capillary electrophoresis or capillary HPLC

    International Nuclear Information System (INIS)

    Inagaki, K.; Fujii, S.; Takatsu, A.; Yarita, T.; Zhu, Y.; Chiba, K.

    2009-01-01

    Full text: Quantification of nucleotides in small volumes of biological samples has eagerly been demanded. A method using ICPMS coupled with capillary electrophoresis or capillary liquid chromatography is reported. A new interface system, which consists of a double tube nebulizer inserted with a fused silica capillary tube and a cylinder mini-chamber with a sheath gas inlet, was designed. Moreover, the surface conditions of the sampling and skimmer cones, and the introduction of H 2 gas into the plasma were found to significantly improve the signal/background ratio for phosphorus determination at m/z 31. (author)

  3. Biopsia por punción con aguja fina sin aspiración en el diagnóstico prequirúrgico del nódulo del tiroides Fine needle biopsy without aspiration in the presurgical diagnosis of thyroid nodule

    Directory of Open Access Journals (Sweden)

    Francisco Ochoa Torres

    2001-12-01

    Full Text Available Se estudió un grupo de 100 pacientes operados de nódulo único del tiroides en el Servicio de Cirugía General del Hospital “Cmdte. Manuel Fajardo”, para validar el método de la biopsia por punción con aguja fina sin aspiración (citopunción en el diagnóstico prequirúrgico de esa afección. A cada paciente se le realizó una citopunción con aguja No. 25 antes de la intervención quirúrgica; los resultados se clasificaron en negativos (benignos y positivos (malignos y sospechosos y la histología posoperatoria, en benigna y maligna, según los intereses de nuestro trabajo y de criterios preestablecidos en el Departamento de Anatomía Patológica del hospital. El 100 % de las muestras fue útil para diagnóstico con una correspondencia entre citopunción e histología del 83 %. Los valores de los indicadores de validación fueron: sensibilidad: 76 %, especificidad: 85 %, valor predictivo positivo: 57 %, valor predictivo negativo: 93 % y eficacia general del método: 85 %. Concluimos que la citopunción es un método diagnóstico útil en el nódulo único del tiroides y que logra iguales resultados que la BAF, pero la primera es más recomendable por ser de más fácil aplicación, menos traumático y más económico.A group of 100 patients operated on of thyroid nodule at the Service of General Surgery of “Comandante Manuel Fajardo” Hospital was studied aimed at validating the method of biopsy by fine needle puncture without aspiration (cytopuncture in the presurgical diagnosis of this disease. Every patient underwent cytopuncture with needle No. 25 before the operation. The results were classified into negative (benign and positive (malignant and suspected, and postoperative histology into benign and malignant, according to the interests of our investigation and to the criteria preestablished at the Department of Pathological Anatomy of the hospital. 100 % of the samples were useful for the diagnosis with a correspondence

  4. Extranodal Non-Hodgkin's Lymphoma of Base of Tongue – Diagnosis by Fine Needle Aspiration Cytology

    Directory of Open Access Journals (Sweden)

    Jaya Manchanda

    2016-01-01

    Full Text Available Waldeyer's ring is the primary site of Non-Hodgkin's Lymphoma (NHL involvement in approximately 5 to 10% of all lymphoma patients. Of all Waldeyer's ring NHLs, the tonsil is the most frequent site,followed by the nasopharynx. Lymphomas arising from base of the tongue are less frequent, accounting for 7% of all primary Waldeyer's ring NHLs. The possible differential diagnosisincludes Squamous Cell Carcinoma (SCC, which is the most common malignancy of the tongue base, salivary gland malignancy, (adenoid cystic carcinoma or mucoepidermoidcarcinoma and infection processes, such as tuberculosis. Here we present a case of 43 year old male presenting with mass lesion of the base of tongue and odynophagia. The diagnosis was initially made by ne needle aspiration of this lesion. Subsequent imaging investigations revealed a lobulated mass inltrating bowel loop in the right iliac fossa. Histopathological and immunohistochemistry tests for both lesions conrmed extra-nodal, primary NHL Bcell diffuse, large cell type.

  5. High-pressure needle interface for thermoplastic microfluidics.

    Science.gov (United States)

    Chen, C F; Liu, J; Hromada, L P; Tsao, C W; Chang, C C; DeVoe, D L

    2009-01-07

    A robust and low dead volume world-to-chip interface for thermoplastic microfluidics has been developed. The high pressure fluidic port employs a stainless steel needle inserted into a mating hole aligned to an embedded microchannel, with an interference fit used to increase pressure resistance. Alternately, a self-tapping threaded needle screwed into a mating hole is also demonstrated. In both cases, the flat bottom needle ports seat directly against the microchannel substrate, ensuring low interfacial dead volumes. Low dispersion is observed for dye bands passing the interfaces. The needle ports offer sufficient pull-out forces for applications such as liquid chromatography that require high internal fluid pressures, with the epoxy-free interfaces compatible with internal microchannel pressures above 40 MPa.

  6. X-ray focusing using capillary arrays

    International Nuclear Information System (INIS)

    Nugent, K.A.; Chapman, H.N.

    1990-01-01

    A new form of X-ray focusing device based on glass capillary arrays is presented. Theoretical and experimental results for array of circular capillaries and theoretical and computational results for square hole capillaries are given. It is envisaged that devices such as these will find wide applications in X-ray optics as achromatic condensers and collimators. 3 refs., 4 figs

  7. Capillary condenser/evaporator

    Science.gov (United States)

    Valenzuela, Javier A. (Inventor)

    2010-01-01

    A heat transfer device is disclosed for transferring heat to or from a fluid that is undergoing a phase change. The heat transfer device includes a liquid-vapor manifold in fluid communication with a capillary structure thermally connected to a heat transfer interface, all of which are disposed in a housing to contain the vapor. The liquid-vapor manifold transports liquid in a first direction and conducts vapor in a second, opposite direction. The manifold provides a distributed supply of fluid (vapor or liquid) over the surface of the capillary structure. In one embodiment, the manifold has a fractal structure including one or more layers, each layer having one or more conduits for transporting liquid and one or more openings for conducting vapor. Adjacent layers have an increasing number of openings with decreasing area, and an increasing number of conduits with decreasing cross-sectional area, moving in a direction toward the capillary structure.

  8. Micro-injector for capillary electrophoresis.

    Science.gov (United States)

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C

    2015-08-01

    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Calcitonin assay in wash-out fluid after fine-needle aspiration biopsy in patients with a thyroid nodule and border-line value of the hormone.

    Science.gov (United States)

    Massaro, F; Dolcino, M; Degrandi, R; Ferone, D; Mussap, M; Minuto, F; Giusti, M

    2009-04-01

    Assaying calcitonin (CT) in the wash-out fluid from fine-needle aspiration biopsies (CT-FNAB) could be useful in the diagnosis of medullary thyroid carcinoma (MTC). The aim of this study was to correlate serum CT with cytology and CT-FNAB. Twenty-seven subjects (age range 27-75 yr) were studied. FNAB was performed in a thyroid nodule (no.=16) or lymph-node (no.=1 previously operated on for MTC) or in the prevalent nodule of multinodular goiters (no.=10). CT-FNAB values obtained in 37 subjects with normal serum CT (thyroid nodules served as a negative control. In these subjects, CTFNAB values were 8.2+/-6.4 ng/l (range 2-30 ng/l). In patients with a thyroid nodule under evaluation for MTC, serum CT and CT-FNAB values were 14.5+/-3.9 ng/l (range 10-24 ng/l) and 16.4+/-29.8 ng/l (range 2-144 ng/l), respectively. In 4 patients, CT-FNAB values were higher than the highest values found in our negative controls (30 ng/l), but cytology results were compatible with a benign thyroid lesion and pentagastrin testing was negative. In 3 cases with CT-FNAB 100 ng/l. Our data do not show any correlation between CT-FNAB and serum CT. In conclusion, borderline CT values in patients with thyroid nodules are not rare. Our experience suggests that CT-FNAB does not have the same importance as that reported in the literature for thyroglobulin and PTH assay in wash-out fluid after FNAB in malignant thyroid and hyperfunctioning parathyroid lesions.

  10. The Problem of Metal Needles in Acupuncture-fMRI Studies

    Directory of Open Access Journals (Sweden)

    Florian Beissner

    2011-01-01

    Full Text Available Acupuncture is a therapy based on sensory stimulation of the human body by means of metal needles. The exact underlying mechanisms of acupuncture have not been clarified so far. Functional magnetic resonance imaging (fMRI has become an important tool in acupuncture research. Standard acupuncture needles, which are made of ferromagnetic steel, however, are problematic in acupuncture-fMRI studies for several reasons, such as attraction by the scanner's magnetic field, significant image distortions and signal-dropouts, when positioned close to the head or even heating due to absorption of radio frequency (RF. The aim of this study was to compare two novel types of acupuncture needles with a standard needle for their effect on MRI image quality. The standard needle severely reduced image quality, when located inside the RF coil. The nonferromagnetic metal needle may pose a risk due to RF heating, while the plastic needle has a significantly larger diameter. In conclusion, our recommendations are: (1 standard needles should not be used in MRI; (2 Nonferromagnetic metal needles seem to be the best choice for acupoints outside of the transmitter coil; and (3 only plastic needles are suited for points inside the coil. Laser acupuncture may be a safe alternative, too.

  11. Design of Capillary Flows with Spatially Graded Porous Films

    Science.gov (United States)

    Joung, Young Soo; Figliuzzi, Bruno Michel; Buie, Cullen

    2013-11-01

    We have developed a new capillary tube model, consisting of multi-layered capillary tubes oriented in the direction of flow, to predict capillary speeds on spatially graded porous films. Capillary flows through thin porous media have been widely utilized for small size liquid transport systems. However, for most media it is challenging to realize arbitrary shapes and spatially functionalized micro-structures with variable flow properties. Therefore, conventional media can only be used for capillary flows obeying Washburn's equation and the modifications thereof. Given this background, we recently developed a method called breakdown anodization (BDA) to produce highly wetting porous films. The resulting surfaces show nearly zero contact angles and fast water spreading speed. Furthermore, capillary pressure and spreading diffusivity can be expressed as functions of capillary height when customized electric fields are used in BDA. From the capillary tube model, we derived a general capillary flow equation of motion in terms of capillary pressure and spreading diffusivity. The theoretical model shows good agreement with experimental capillary flows. The study will provide novel design methodologies for paper-based microfluidic devices.

  12. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  13. Visualization and quantification of capillary drainage in the pore space of laminated sandstone by a porous plate method using differential imaging X-ray microtomography

    Science.gov (United States)

    Lin, Qingyang; Bijeljic, Branko; Rieke, Holger; Blunt, Martin J.

    2017-08-01

    The experimental determination of capillary pressure drainage curves at the pore scale is of vital importance for the mapping of reservoir fluid distribution. To fully characterize capillary drainage in a complex pore space, we design a differential imaging-based porous plate (DIPP) method using X-ray microtomography. For an exemplar mm-scale laminated sandstone microcore with a porous plate, we quantify the displacement from resolvable macropores and subresolution micropores. Nitrogen (N2) was injected as the nonwetting phase at a constant pressure while the porous plate prevented its escape. The measured porosity and capillary pressure at the imaged saturations agree well with helium measurements and experiments on larger core samples, while providing a pore-scale explanation of the fluid distribution. We observed that the majority of the brine was displaced by N2 in macropores at low capillary pressures, followed by a further brine displacement in micropores when capillary pressure increases. Furthermore, we were able to discern that brine predominantly remained within the subresolution micropores, such as regions of fine lamination. The capillary pressure curve for pressures ranging from 0 to 1151 kPa is provided from the image analysis compares well with the conventional porous plate method for a cm-scale core but was conducted over a period of 10 days rather than up to few months with the conventional porous plate method. Overall, we demonstrate the capability of our method to provide quantitative information on two-phase saturation in heterogeneous core samples for a wide range of capillary pressures even at scales smaller than the micro-CT resolution.

  14. Her-2 neu (Cerb-B2 expression in fine needle aspiration samples of breast carcinoma: A pilot study comparing FISH, CISH and immunocytochemistry

    Directory of Open Access Journals (Sweden)

    Kusum Kapila

    2011-01-01

    Full Text Available Background: Breast cancers with Her-2 neu gene amplification are recognized as important markers for aggressive disease and targets which respond to therapy with trastuzumab. Her-2 neu testing on histological sections is routinely performed to select patients who may benefit from anti- Her-2 neu therapy. Few reports are available which document Her-2 neu status on fine needle aspirates (FNA. Aim: This pilot study is to document expression of Her-2 neu (Cerb-B2 on cytospin smears from FNA of patients with breast carcinoma. Materials and Methods: Twenty samples of FNA already collected for diagnostic purposes from patients with primary breast carcinoma were studied for demonstration of Her-2 neu expression by immunohistochemistry (IHC, Fluorescent in-situ hybridization (FISH and chromogenic in-situ hybridization (CISH on cytospin smears from FNA. Their expression was compared with tissue sections where possible. Results: Good correlation was observed between Her-2 neu protein expression and gene amplification in cytospin smears. Three of five (60% breast carcinomas cases with 2+ and 3+ staining on IHC showed gene amplification by FISH and CISH. Three of 7 (43% and 5 of 7 (71% cases negative/1+ staining on IHC did not show gene amplification by FISH and CISH respectively. Tissue sections from 10 cases with 2+ and 3+ staining for Her2neu by IHC showed gene amplification in 8 cases. Conclusion: Demonstration of Her-2 neu by IHC, FISH or CISH in FNA is possible and may play a role in the management of patients with advanced breast cancer or those cases where surgical resection is not advisable.

  15. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  16. Laser-Controlled Growth of Needle-Shaped Organic Nanoaggregates

    DEFF Research Database (Denmark)

    Balzer, Frank; Rubahn, Horst-Günter

    2002-01-01

    Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometer....... While the orientation of the individual molecules in the needles is defined by the direction of surface dipoles, the localization on the surface, the length distribution as well as mutual distances can be adjusted via size and position of the laser focus spot.......Arrays of mutually parallel oriented, single-crystalline, needle-like structures of light-emitting p-hexaphenyl molecules are generated in the focus of an argon ion laser. The cross sectional dimensions of the needles are of the order of 100 to 200 nm with lengths up to several hundred micrometers...

  17. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  18. Proper Use of Capillary Number in Chemical Flooding

    Directory of Open Access Journals (Sweden)

    Hu Guo

    2017-01-01

    Full Text Available Capillary number theory is very important for chemical flooding enhanced oil recovery. The difference between microscopic capillary number and the microscopic one is easy to confuse. After decades of development, great progress has been made in capillary number theory and it has important but sometimes incorrect application in EOR. The capillary number theory was based on capillary tube bundles and Darcy’s law hypothesis, and this should always be kept in mind when used in chemical flooding EOR. The flow in low permeability porous media often shows obvious non-Darcy effects, which is beyond Darcy’s law. Experiments data from ASP flooding and SP flooding showed that remaining oil saturation was not always decreasing as capillary number kept on increasing. Relative permeability was proved function of capillary number; its rate dependence was affected by capillary end effects. The mobility control should be given priority rather than lowering IFT. The displacement efficiency was not increased as displacement velocity increased as expected in heavy oil chemical flooding. Largest capillary number does not always make highest recovery in chemical flooding in heterogeneous reservoir. Misuse of CDC in EOR included the ignorance of mobility ratio, Darcy linear flow hypothesis, difference between microscopic capillary number and the microscopic one, and heterogeneity caused flow regime alteration. Displacement of continuous oil or remobilization of discontinuous oil was quite different.

  19. Primary pulmonary non-small cell carcinomas: the College of American Pathologists Interlaboratory Comparison Program confirms a significant trend toward subcategorization based upon fine-needle aspiration cytomorphology alone.

    Science.gov (United States)

    Yildiz-Aktas, Isil Z; Sturgis, Charles D; Barkan, Guliz A; Souers, Rhona J; Fraig, Mostafa M; Laucirica, Rodolfo; Khalbuss, Walid E; Moriarty, Ann T

    2014-01-01

    Context.-Subtyping of non-small cell lung carcinomas (NSCLCs) is necessary for optimal patient management with specific diagnoses triggering specific molecular tests and affecting therapy. Objective.-To assess the accuracy of the participants of the College of American Pathologists Interlaboratory Comparison Program in diagnosing and subtyping NSCLC fine-needle aspiration (FNA) slides, based on morphology alone, considering preparation and participant type and trends over time. Design.-The performance of program participants was reviewed for the 5-year period spanning 2007-2011. Lung FNA challenges with reference diagnoses of adenocarcinoma and squamous cell carcinoma (SCC) were evaluated for diagnostic concordance by using a nonlinear mixed model analysis. Results.-There were 10 493 pathologist and 6378 cytotechnologist responses with concordance rates of 97.4% and 97.9% for malignancy, respectively. Overall concordance rates for subcategorization were 54.6% for adenocarcinoma and 74.9% for SCC. For the exact reference diagnoses, pathologists performed better for adenocarcinoma and cytotechnologists performed better for SCC. Accurate subcategorization of adenocarcinomas significantly increased over time with 31.5% of adenocarcinomas classified as NSCLC in 2007 and 25.5% of adenocarcinomas classified as NSCLC in 2011 (P alone. During the study period, a statistically significant trend was confirmed toward greater accuracy of subcategorization of adenocarcinomas, suggesting that participants are cognizant of the impact that more specific cytomorphologic interpretations have in directing molecular triage and therapy.

  20. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    Science.gov (United States)

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.

    2014-06-17

    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.