  1. Alpha particle emitters in medicine

    International Nuclear Information System (INIS)

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 (211At) and natural bismuth-212 (212Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 (223Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs

  2. Alpha particle emitters in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, D.R.

    1989-09-01

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 ({sup 211}At) and natural bismuth-212 ({sup 212}Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 ({sup 223}Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs.

  3. Alpha-emitters for medical therapy workshop

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E.; McClure, J.J.

    1996-12-31

    A workshop on ``Alpha-Emitters for Medical Therapy`` was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference.

  4. Therapeutic use of alpha-emitters

    Energy Technology Data Exchange (ETDEWEB)

    Lassmann, M. [Klinik und Poliklinik fuer Nuklearmedizin der Univ. Wuerzburg (Germany)

    2005-07-01

    In recent years there is a growing interest in the therapeutic use of {alpha}-emitters for patient treatment, {alpha}-particles have much higher energy and their range is only a few cell diameters. Their high LET and the limited ability of cells to repair DNA damage from {alpha}-radiation explain their high relative biological effectiveness and cytotoxicity. Potential {alpha}-emitting isotopes for therapeutic applications are {sup 224}Ra, {sup 223}Ra, {sup 213}Bi and {sup 211}At. The treatment with {alpha}-particles is focused upon targeted cancer therapy using radiolabeled monoclonal antibodies, on palliation of bone metastases or upon pain relief in patients with ankylosing spondylitis (AS). Examples for targeted cancer therapy are the treatment of melanoma with {sup 213}Bi and non-Hodgkin lymphoma with {sup 211}At. For metastatic bone pain palliation {sup 223}Ra was applied in a phase I clinical trial. For amelioration of pain in AS-patients {sup 224}Ra-chloride is used. This radiopharmaceutical is licensed for this particular application in Germany. Today there are some potential clinical applications for {alpha}-emitters although most of them are in the state of scientific, non-routine investigations. In-vivo dosimetry for risk assessment associated with this treatment is even more difficult to perform than for therapies using beta-emitting radiopharmaceuticals. (orig.)

  5. Lyman Alpha Emitter Evolution Through Reionization

    CERN Document Server

    Dayal, P; Saro, A; Salvaterra, R; Borgani, S; Tornatore, L

    2009-01-01

    Combining cosmological SPH simulations with a previously developed Lyman Alpha production/transmission model and the Early Reionization Model (ERM, reionization ends at redshift z~7), we obtain Lyman Alpha and UV Luminosity Functions (LFs) for Lyman Alpha Emitters (LAEs) for redshifts between 5.7 and 7.6. Matching model results to observations at z~5.7 requires escape fractions of Lyman Alpha, f_alpha=0.3, and UV (non-ionizing) continuum photons, f_c=0.22, corresponding to a color excess, E(B-V)=0.15. We find that (i) f_c increases towards higher redshifts, due the decreasing mean dust content of galaxies, (ii) the evolution of f_alpha/f_c hints at the dust content of the ISM becoming progressively inhomogeneous/clumped with decreasing redshift. The clustering photoionization boost is important during the initial reionization phases but has little effect on the Lyman Alpha LF for a highly ionized IGM. With no more free parameters, the Spectral Energy Distributions of three LAE at z~5.7 observed by Lai et al. ...

  6. Signatures of reionization on Lyman alpha emitters

    CERN Document Server

    Dayal, Pratika; Gallerani, Simona

    2008-01-01

    We use a semi-analytic model of Lyman alpha emitters (LAEs) to constrain the reionization history. By considering two physically motivated scenarios in which reionization ends either early (ERM, z_i ~ 7) or late (LRM, z_i ~ 6), we fix the global value of the IGM neutral fraction (e.g. chi_{HI}=3 times 10^{-4}, 0.15 at z=6.56 for the ERM and LRM, respectively) leaving only the star formation efficiency and the effective escape fraction of Lya photons as free parameters. The ERM fits the observed LAE luminosity function (LF) at z=5.7 and 6.56 requiring no redshift evolution or mass dependence of the star formation efficiency, and LAE star formation rates (SFR) of 3-103 solar masses/year, contributing approximately 8% of the cosmic SFR density at z=5.7. The LRM requires a physically uncomfortable drop of approximately 4.5 times in the SFR of the emitters from z=6.5 to 5.7. Thus, the data seem to imply that the Universe was already highly ionized at z=6.56. The mass-dependent Lya transmissivity is between 0.36-0....

  7. Modelling high redshift Lyman-alpha Emitters

    CERN Document Server

    Garel, Thibault; Guiderdoni, Bruno; Schaerer, Daniel; Verhamme, Anne; Hayes, Matthew

    2012-01-01

    We present a new model for high redshift Lyman-Alpha Emitters (LAEs) in the cosmological context which takes into account the resonant scattering of Ly-a photons through expanding gas. The GALICS semi-analytic model provides us with the physical properties of a large sample of high redshift galaxies. We implement a gas outflow model for each galaxy based on simple scaling arguments. The coupling with a library of numerical experiments of Ly-a transfer through expanding or static dusty shells of gas allows us to derive the Ly-a escape fractions and profiles. The predicted distribution of Ly-a photons escape fraction shows that galaxies with a low star formation rate have a f_esc of the order of unity, suggesting that, for those objects, Ly-a may be used to trace the star formation rate assuming a given conversion law. In galaxies forming stars intensely, the escape fraction spans the whole range from 0 to 1. The model is able to get a good match to the UV and Ly-a luminosity function (LF) data at 3 < z <...

  8. Molecular hydrogen in Lyman Alpha Emitters

    CERN Document Server

    Vallini, Livia; Ferrara, Andrea

    2012-01-01

    We present a physically motivated model to estimate the molecular hydrogen (H2) content of high-redshift (z~5.7,6.6) Lyman Alpha Emitters (LAEs) extracted from a suite of cosmological simulations. We find that the H2 mass fraction, (f_H2), depends on three main LAE physical properties: (a) star formation rate, (b) dust mass, and (c) cold neutral gas mass. At z~5.7, the value of f_H2 peaks and ranges between 0.5-0.9 for intermediate mass LAEs with stellar mass M_* ~ 10^{9-10} solar mass, decreasing for both smaller and larger galaxies. However, the largest value of the H2 mass is found in the most luminous LAEs. These trends also hold at z\\sim6.6, although, due to a lower dust content, f_H2(z=6.6)\\sim0.5 f_H2(z=5.7) when averaged over all LAEs; they arise due to the interplay between the H2 formation/shielding controlled by dust and the intensity of the ultraviolet (UV) Lyman-Werner photo-dissociating radiation produced by stars. We then predict the carbon monoxide (CO) luminosities for such LAEs and check tha...

  9. Quantum Estimates of Alpha Emitter Life Time

    Directory of Open Access Journals (Sweden)

    B. Santoso

    2006-01-01

    Full Text Available Quantum estimates of several alpha radioactive life time have been made using the probability of quantum tunneling through the nuclear potential barrier. It is assumed that for a given nucleus with mass number A and isotopic number Z, there exists an alpha particle moving freely back and forth in the nucleus with mass and isotopic numbers A -4 and Z-2. If the probability of penetrating the nuclear potential barrier is Τ, then after N times (N=1/Τ hitting the barrier an alpha particle is emitted. To obtain the elapsed time for emitting an alpha particle requires N times τ0, where τ0 is the time travel for alpha across the nuclear diameter, which is dependent on alpha energy. It is assumed here that this kinetic energy is the same as the emitted energy. The emitting alpha kinetic energies here are calculated by the difference of the masses of the parent and daughter nuclei and the alpha particles. They are in closed agreement with the experimental observations. While the alpha radioactive life time are not the same order of magnitudes but give the same linearity on the logarithmic scale as function of the inverse square root of energy.

  10. MFTF-. cap alpha. + T progress report

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, W.D. (ed.)

    1985-04-01

    Early in FY 1983, several upgrades of the Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory (LLNL) were proposed to the fusion community. The one most favorably received was designated MFTF-..cap alpha..+T. The engineering design of this device, guided by LLNL, has been a principal activity of the Fusion Engineering Design Center during FY 1983. This interim progress report represents a snapshot of the device design, which was begun in FY 1983 and will continue for several years. The report is organized as a complete design description. Because it is an interim report, some parts are incomplete; they will be supplied as the design study proceeds. As described in this report, MFTF-..cap alpha..+T uses existing facilities, many MFTF-B components, and a number of innovations to improve on the physics parameters of MFTF-B. It burns deuterium-tritium and has a central-cell Q of 2, a wall loading GAMMA/sub n/ of 2 MW/m/sup 2/ (with a central-cell insert module), and an availability of 10%. The machine is fully shielded, allows hands-on maintenance of components outside the vacuum vessel 24 h after shutdown, and has provisions for repair of all operating components.

  11. Effects of internally deposited alpha emitters

    International Nuclear Information System (INIS)

    This study seeks to identify and quantify the human health effects of occupational exposures to radium, use the health effects data from the radium study to predict responses to other alpha-emitting and/or bone-seeking radionuclides at occupational exposure levels and above, and predict the effects of these radionuclides, specifically environmental radium and its daughters, at nonoccupational exposure levels. 14 refs

  12. Risk estimates for exposure to alpha emitters

    International Nuclear Information System (INIS)

    The primary scope of this report is to evaluate the risk of lung cancer from occupational exposure to short-lived daughters of radon and thoron. The Subcommittee on Risk Estimates considers that inhalation of radon and thoron daughters is the major radiation hazard from alpha radiation in uranium mining. The secondary scope of this report is the consideration of the applicability of the risk estimates derived from miners to the general public. The risk to members of the public from radium-226 in drinking water is also considered. Some research requirments are suggested

  13. Trafficking of. cap alpha. -L-fucosidase in lymphoid cells

    Energy Technology Data Exchange (ETDEWEB)

    DiCioccio, R.A.; Brown, K.S.

    1987-05-01

    The quantity of ..cap alpha..-L-fucosidase in human serum is determined by heredity. The mechanism controlling levels of the enzyme in serum is unknown. To investigate this, lymphoid cell lines derived from individuals with either low, intermediate or high ..cap alpha..-L-fucosidase in serum were established. Steady state levels of extracellular ..cap alpha..-L-fucosidase protein and activity overlapped among the cell lines. Thus, in vivo serum phenotypes of ..cap alpha..-L-fucosidase are not adequately expressed in this system. ..cap alpha..-L-Fucosidase was also metabolically labelled with /sup 35/S-methionine, immunoprecipitated, and examined by SDS-PAGE. Cells pulse-labelled from 0.25-2 h had a major intracellular form of enzyme (Mr = 58,000). Cells pulsed for 1.5 h and chased for 21 h with unlabeled methionine had an intracellular form of Mr = 60,000 and an extracellular form of Mr = 62,000. Cells treated with chloroquine had only the 58,000-form both intra- and extra-cellularly. Moreover, chloroquine did not effect the quantitative distribution of ..cap alpha..-L-fucosidase between cells and medium. In fibroblasts, chloroquine enhanced the secretion of newly made lysosomal enzymes and blocked the processing of intercellular enzyme forms from a higher to a lower molecular mass. Thus, there are trafficking differences between ..cap alpha..-L-fucosidase in lymphoid cells and lysosomal enzymes in fibroblasts. This suggests that alternative targeting mechanisms for lysosomal enzymes exist in these cells.

  14. Gaseous alpha emitter diffusion studies using alpha track method

    International Nuclear Information System (INIS)

    Using a very accurate and sensitive analysis method such as alpha track method, the SSNTD group was able to undertake studies on the atomic and molecular processes taking place at low speed and/or very low concentrations, such as diffusion of gaseous alpha radionuclides in gaseous media. For practical application reasons, we began to study the diffusion in air for gaseous alpha radionuclides and aerosols carrying solid alpha radionuclides. The used alpha radionuclides were: Rn-222, as gaseous radionuclide and its solid descendants genetically related, attached to different particles from air, as radioactive aerosols. The source was included into an air tight device with a very well known volume. After 40 days, the radioactive equilibrium was established for all descendants, so that in the device there were the Rn-222 and its descendants, each of them having the same activity. The relative amount/activity ratio of each decay product, at any duration, for any initial mass of Ra-226 parent radionuclide, were calculated using the code UURASE, based on the Bateman general equations, for computing the U-238 radioactive series gamma accumulation. This was adapted for alpha accumulation as ALFAURASE programme. The device which contains the Ra-226 source can be coupled to the calibration system or to the diffusion system, without destroying the radioactive equilibrium. At this coupling, only the radioactive concentration is changed due to the variation of the volume. First of all the device was used for calibrating the CR-39 track detectors for both Rn-222 gaseous radionuclide and aerosol concentration measurements using, in the coupled calibration system, a special 'detector-container' equipped/or not with a filter used for radioactive aerosol stopping. The track detectors CR-39 were etched in NaOH 30%, for 7 hours at 70 deg. C and their studies were performed by optical microscopy using a stereo-microscope Wild M7S and a binocular Zeiss Jena microscope. (authors)

  15. Joint Ly{\\alpha} emitters - quasars reionization constraints

    CERN Document Server

    Baek, S; Semelin, B

    2012-01-01

    We present a novel method to investigate cosmic reionization, using joint spectral information on high redshift Lyman Alpha Emitters (LAE) and quasars (QSOs). Although LAEs have been proposed as reionization probes, their use is hampered by the fact their Ly{\\alpha} line is damped not only by intergalactic HI but also internally by dust. Our method allows to overcome such degeneracy. First, we carefully calibrate a reionization simulation with QSO absorption line experiments. Then we identify LAEs in two simulation boxes at z=5.7 and z=6.6 and we build synthetic images/spectra of a prototypical LAE. At redshift 5.7, we find that the Ly{\\alpha} transmissivity (T_LAE) ~ 0.25, almost independent of the halo mass. This constancy arises from the conspiracy of two effects: (i) the intrinsic Ly{\\alpha} line width and (ii) the infall peculiar velocity. At higher redshift, z=6.6, where the transmissivity is instead largely set by the local HI abundance and LAE transmissivity consequently increases with halo mass from ...

  16. MIRD Pamphlet No. 22 (Unabridged): Radiobiology and Dosimetry of alpha-Particle Emitters for Targeted Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sgouros, George; Roeske, John C.; McDevitt, Michael S.; Palm, Stig; Allen, Barry J.; Fisher, Darrell R.; Brill, Bertrand A.; Song, Hong; Howell, R. W.; Akabani, Gamal

    2010-02-28

    The potential of alpha-particle emitters to treat cancer has been recognized since the early 1900s. Advances in the targeted delivery of radionuclides, in radionuclide conjugation chemistry, and in the increased availability of alpha-emitters appropriate for clinical use have recently led to patient trials of alpha-particle-emitter labeled radiopharmaceuticals. Although alpha-emitters have been studied for many decades, their current use in humans for targeted therapy is an important milestone. The objective of this work is to review those aspects of the field that are pertinent to targeted alpha-particle-emitter therapy and to provide guidance and recommendations for human alpha-particle-emitter dosimetry.

  17. Mechanism of radiation graft of methyl-. cap alpha. -fluoroacrylate and. cap alpha. ,. beta. ,. beta. -trifluorostyrene on perfluorinated copolymer. [Cobalt 60

    Energy Technology Data Exchange (ETDEWEB)

    Ivankin, A.N.; Tevlina, A.S.; Zagorets, P.A. (Moskovskij Khimiko-Tekhnologicheskij Inst. (USSR))

    1983-04-01

    The kinetics of radiation-induced graft copolymerization of methyl-..cap alpha..-fluoroacrylate and ..cap alpha.., ..beta.., ..beta..-trifluorostyrene to perfluorinated copolymer of hexafluoropropylene with tetrafluoroethylene has been studied. The orders of the grafting reaction towards the monomer and dose rate as well as the values of rate constants of radiation-induced grafting at various temperatures were determined, the effective activation energy of grafting (20.6 kJ/mol) was calculated. The kinetic scheme of elementary acts of radiation-induced graft copolymerization is discussed.

  18. Determination of substraces of alpha emitter elements in water

    International Nuclear Information System (INIS)

    To determine alpha emitter elements in water by alpha spectrometry, it is necessary to use large volumes of samples, concentration techniq-ues and to separate the elements of interest. In this report a study is presented about two concentration techniques and the process of analysis. Firstly, the stages of concentration method by iron hydroxide coprecipitation were studied in order to improve the results. The combination of liquid-liquid extraction and ion exchange techniques was the best way. Secondly, the technique by adsorption on manganese dioxide was studied. To apply this technique it was necessary to develop analysis methods to separate uranium, thorium, plutonium, americium and radium. These methods were designed combining several techniques of separation: liquid-liquid extraction, liquid-solid extraction, ionic exchange and coprecipitation. After the analysis methods were developped the adsorption on manganese dioxide with artificial samples was studied in the laboratory. Finally, the method of adsorption on manganese dioxide was studied to determine uranium, thorium and radium in the drinking water of Madrid. (Author)

  19. The HETDEX Pilot Survey & 3DHST: What Makes a Lyman-alpha Emitter?

    Science.gov (United States)

    Hagen, Alex; Zeimann, Gregory; Gronwall, Caryl; Ciardullo, Robin; Bridge, Joanna; Hetdex

    2015-01-01

    We compare the 3D-HST H-beta emitters at z~2 to Lyman-alpha emitters found in the same redshift range by the HETDEX Pilot Survey to investigate any differences in the physical and morphological parameters that could elucidate how or why Lyman-alpha is escaping. We use one-dimensional and multi-dimensional statistics, as well as machine learning techniques to try to find differences between these datasets. However, we are unable to find statistically significant differences between these populations. This demonstrates that Lyman-alpha emitters are pulled randomly from the distribution of star-forming galaxies, and there are seemly no strong physical or morphological requirements to be a Lyman-alpha emitter. We also use this information to inform a toy model of Lyman-alpha emission that poses all star-forming galaxies are LAEs if view along certain lines of sight.

  20. Lyman alpha emitter evolution in the reionization epoch

    Science.gov (United States)

    Dayal, P.; Ferrara, A.; Saro, A.; Salvaterra, R.; Borgani, S.; Tornatore, L.

    2009-12-01

    Combining cosmological smoothed particle hydrodynamics (SPH) simulations with a previously developed Lyα production/transmission model and the Early Reionization Model (ERM; reionization ends at redshift z ~ 7), we obtain Lyα and UV luminosity functions (LFs) for lyman alpha emitters (LAEs) at 5.7 ERM. However, during the initial reionization phases (z >~ 7), the clustering photoionization boost becomes important. We quantify the physical properties of observed LAEs and their redshift evolution, for which we give handy analytical fitting functions. Halo (stellar) masses are in the range 10.0 20 Myr at all redshifts, while the mean stellar metallicity increases from Z = 0.12Zsolar at z ~ 7.6 to Z = 0.22Zsolar at z ~ 5.7; both t* and Z positively correlate with stellar mass. The brightest LAEs are all characterized by large and intermediate ages (~200Myr), while objects in the faint end of the Lyα LF show large age and star formation rate spreads. With no more free parameters, the spectral energy distributions of three LAE at z ~ 5.7 observed by Lai et al. (2007) are well reproduced by an intermediate age (182-220 Myr) stellar population and the above E(B - V) value. The model uncertainties, mostly related to the simplified treatment of dust and to the possible effects related to gas outflow/infall, are discussed along with their impact on the results.

  1. Ly-alpha Radiative Transfer in Cosmological Simulations and Application to a z~8 Emitter

    CERN Document Server

    Tasitsiomi, A

    2005-01-01

    We develop a Ly-alpha radiative transfer (RT) Monte Carlo code for cosmological simulations.High resolution,along with appropriately treated cooling can result in simulated environments with very high optical depths.Thus,solving the Ly-alpha RT problem in cosmological simulations can take an unrealistically long time.For this reason,we develop methods to speed up the Ly-alpha RT.With these accelerating methods,along with the parallelization of the code,we make the problem of Ly-alpha RT in the complex environments of cosmological simulations tractable.We test the RT code against simple Ly-alpha emitter models,and then we apply it to the brightest Ly-alpha emitter of a gasdynamics+N-body Adaptive Refinement Tree (ART) simulation at z~8.We find that recombination rather than cooling radiation Ly-alpha photons is the dominant contribution to the intrinsic Ly-alpha luminosity of the emitter,which is ~2.3x10e44 ergs/s.The size of the emitter is pretty small,making it unresolved for currently available instruments....

  2. A device for the remote detection of alpha emitters under field conditions

    NARCIS (Netherlands)

    Simakov, AB

    2005-01-01

    The portable DOP device was designed for the ecological monitoring of the radiation of alpha radioactive nuclides, such as plutonium, uranium, radium, etc. Under field conditions, it can detect alpha emitters at distances of up to 0.5 m. The device's performance data are as follows: the lower thresh

  3. Radioimmunoassay determination of decreased amounts of. cap alpha. -L-fucosidase protein in fucosidosis

    Energy Technology Data Exchange (ETDEWEB)

    Andrews-Smith, G.L.; Alhadeff, J.A. (California Univ., San Diego, La Jolla (USA). Dept. of Neurosciences)

    1982-03-15

    Purified human liver ..cap alpha..-L-fucosidase (EC 3.2.1.51) has been radioiodinated by a chloramine-T procedure to a specific activity of 3.7 x 10/sup 6/ dpm/..mu..g protein without altering its apparent Michaelis constant for the 4-methylumbelliferyl substrate. This /sup 125/I-labeled ..cap alpha..-L-fucosidase has been used in development of a competitive binding radioimmunoassay for ..cap alpha..-L-fucosidase which can detect 1-2 ng of enzyme protein and has been employed to quantify the amount of ..cap alpha..-L-fucosidase protein in the liver and spleen from a patient with fucosidosis. Less than 1% of the normal amount of ..cap alpha..-L-fucosidase protein is present suggesting that normal amounts of catalytically inactive ..cap alpha..-L-fucosidase are not found in this disease.

  4. Concept of a (1-. cap alpha. ) performance confidence interval

    Energy Technology Data Exchange (ETDEWEB)

    Leong, H.H.; Johnson, G.R.; Bechtel, T.N.

    1980-01-01

    A multi-input, single-output system is assumed to be represented by some model. The distribution functions of the input and the output variables are considered to be at least obtainable through experimental data. Associated with the computer response of the model corresponding to given inputs, a conditional pseudoresponse set is generated. This response can be constructed by means of the model by using the simulated pseudorandom input variates from a neighborhood defined by a preassigned probability allowance. A pair of such pseudoresponse values can then be computed by a procedure corresponding to a (1-..cap alpha..) probability for the conditional pseudoresponse set. The range defined by such a pair is called a (1-..cap alpha..) performance confidence interval with respect to the model. The application of this concept can allow comparison of the merit of two models describing the same system, or it can detect a system change when the current response is out of the performance interval with respect to the previously identified model. 6 figures.

  5. ACTH and. cap alpha. -melanotropin in central temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Lipton, J.M.; Glyn, J.R.; Zimmer, J.A.

    1981-11-01

    Adrenocorticotropin (ACTH) and ..cap alpha..-melanotropin (..cap alpha..-MSH) occur in brain tissue known to be important to temperature control. These peptides cause hypothermia if they are injected centrally in sufficient doses, but they do not act on the central set point of temperature control. Instead they appear to inhibit central pathways for heat conservation and production. In addition to their hypothermic capability, these peptides are antipyretic when given centrally in doses that have no effect on normal body temperature. ACTH has previously been associated with fever reduction in both clinical and experimental studies, and it may be that endogenous central ACTH is important for limitation of maximal fever. The hypothermic and antipyretic effects of ACTH do not depend on stimulation of the adrenal cortex because they are also observed in adrenalectomized rabbits. Nor is the antipyretic effect limited to the rabbit inasmuch as a comparable effect has been demonstrated in the squirrel monkey. The two peptides may be involved in central mediation of normal thermoregulation and fever, perhaps limiting the febrile response and other rises in body temperature by acting as neurotransmitters or neuromodulators in central thermoregulatory pathways.

  6. Constraining the Lyman Alpha Escape Fraction with Far-Infrared Observations of Lyman Alpha Emitters

    CERN Document Server

    Wardlow, Julie L; Zheng, Z; Finkelstein, S; Bock, J; Bridge, C; Calanog, J; Ciardullo, R; Conley, A; Cooray, A; Farrah, D; Gawiser, E; Gronwall, C; Heinis, S; Ibar, E; Ivison, R J; Marsden, G; Oliver, S J; Rhoads, J; Riechers, D; Schulz, B; Smith, A J; Viero, M; Wang, L; Zemcov, M

    2013-01-01

    We study the far-infrared properties of 498 Lyman Alpha Emitters (LAEs) at z=2.8, 3.1 and 4.5 in the Extended Chandra Deep Field-South, using 250, 350 and 500 micron data from the Herschel Multi-tiered Extragalactic Survey (HerMES) and 870 micron data from the LABOCA ECDFS Submillimeter Survey (LESS). None of the 126, 280 or 92 LAEs at z=2.8, 3.1 and 4.5, respectively, are individually detected in the far-infrared data. We use stacking to probe the average emission to deeper flux limits, reaching $1\\sigma$ depths of ~0.1 to 0.4 mJy. The LAEs are also undetected at $\\ge3\\sigma$ in the stacks, although a $2.5\\sigma$ signal is observed at 870 micron for the z=2.8 sources. We consider a wide range of far-infrared spectral energy distributions (SEDs), including a M82 and an Sd galaxy template, to determine upper limits on the far-infrared luminosities and far-infrared-derived star-formation rates of the LAEs. These star-formation rates are then combined with those inferred from the Ly$\\alpha$ and UV emission to de...

  7. Optical imaging of alpha emitters: simulations, phantom, and in vivo results

    Science.gov (United States)

    Boschi, Federico; Meo, Sergio Lo; Rossi, Pier Luca; Calandrino, Riccardo; Sbarbati, Andrea; Spinelli, Antonello E.

    2011-12-01

    There has been growing interest in investigating both the in vitro and in vivo detection of optical photons from a plethora of beta emitters using optical techniques. In this paper we have investigated an alpha particle induced fluorescence signal by using a commercial CCD-based small animal optical imaging system. The light emission of a 241Am source was simulated using GEANT4 and tested in different experimental conditions including the imaging of in vivo tissue. We believe that the results presented in this work can be useful to describe a possible mechanism for the in vivo detection of alpha emitters used for therapeutic purposes.

  8. Study of /sup 3/H+. cap alpha. and /sup 3/He+. cap alpha. elastic scattering in a state with zero orbital angular momentum

    Energy Technology Data Exchange (ETDEWEB)

    Chopovskii, L. L.

    1988-12-01

    An asymptotic wave function of the relative motion of clusters at zero interaction energy is derived in the oscillator representation. The set of equations of the algebraic version of the resonating-group method (RGM) is transformed to the zero-energy limit of the relative cluster motion. The /sup 3/H+..cap alpha.. and /sup 3/He+..cap alpha.. scattering lengths are calculated in the single-channel RGM variant on the basis of the derived equations. The possibility of experimentally observing large scattering lengths for light charged clusters is predicted, viz., /similar to/10--23 F in the /sup 3/H+..cap alpha.. channel and /similar to/30--82 F in the /sup 3/He+..cap alpha.. channel.

  9. Localization of alpha emitters by damage production in a thin film. Application to the study of alpha emitter diffusion in irradiated samples

    International Nuclear Information System (INIS)

    The process of recording α particles on cellulose nitrate films, called alpha-graphy, is applied to the study of the diffusion of α-emitting elements in irradiated alloys. The existence of diffusion is shown by attacking the film with concentrated caustic soda after exposition. The insensitivity of the recorder to β γ radiation emitted by the sample after passing in the reactor makes it possible to operate with long exposure times and to detect small diffusions. The concentration-penetration curves are drawn up after carrying out a densitometric analysis of the alpha-graphies. - As the cellulose nitrate is affected only by α particles of energies of between 0.5 and 4 MeV, it was first necessary to determine the yield of the recorder for α particles emitted by a thick source, i.e. whose energy varies between 0 and E0, E0 being the energy of the alpha emitter. - The concentration C of the α-emitter, as a function of the optical density D of the alpha-graphy, and of the exposure time t is given by a simple relationship: C = D/at where a is an experimental constant determined by calibration. It depends on the nature of the cellulose nitrate, of the α-emitting element and of the alloy studied. (authors)

  10. Can galactic outflows explain the properties of Ly-alpha emitters?

    CERN Document Server

    Orsi, Alvaro; Baugh, Carlton M

    2011-01-01

    We study the properties of Ly-alpha emitters in a cosmological framework by computing the escape of Ly-alpha photons through galactic outflows. We combine the GALFORM semi-analytical model of galaxy formation with a Monte Carlo Ly-alpha radiative transfer code. The properties of Ly-alpha emitters at 0alpha line profiles predicted by the two outflow geometries in terms of their width, asymmetry and shift from the line centre for a set of outflows with different hydrogen column densities, expansion velocities and metallicities. In general, the Ly-alpha line profile of the Shell geometry is broader and more asymmetric, and the Ly-alpha escape fraction is lower than with the Wind geometry for the same set of parameters. In order to implement the outflow geometries in the semi-analytical model GALFORM, a number of free parameters ...

  11. Alpha emitters in nuclear waste. Extension of the procedure for low and medium level activity waste

    International Nuclear Information System (INIS)

    The present paper describes a separative method for the determination of U, Pu, Am, Np, Th and Cm as alpha emitters and 3H, Sr, and Ni as beta emitters, when present in aqueous samples of nuclear waste, by using chromatographic separations, liquid scintillation counting and alpha spectrometry. The main separation is performed in one step by coprecipitation of the alpha emitters with yttrium hydroxide at pH = 9-10 after distillation of tritium until dryness and dissolution of the residue in 2M HCI. Actinides are precipitated while strontium and nickel remain in supernatant. Nickel is separated by precipitation with dimetyglioxime in the supernatant and measured by LSC. Strontium is separated by chromatography after conditioning the supernatant (which also contained nickel) and measured by LSC. The actinides fraction is re dissolved in nitric acid and percolated through three chromatographic columns (TEVA, U-TEVA and TRU-SPEC) conditioning the different fractions for measuring by alpha spectrometry. The spectra of the different fractions are presented together with the detection limits and the recoveries obtained on spiked samples. (author)

  12. Deletional rearrangement in the human T-cell receptor. cap alpha. -chain locus

    Energy Technology Data Exchange (ETDEWEB)

    de Villartay, J.P.; Lewis, D.; Hockett, R.; Waldmann, T.A.; Korsmeyer, S.J.; Cohen, D.I.

    1987-12-01

    The antigen-specific receptor on the surface of mature T lymphocytes is a heterodimer consisting of polypeptides termed ..cap alpha.. and ..beta... In the course of characterizing human T-cell tumors with an immature (CD4/sup -/, CD8/sup -/) surface phenotype, the authors detected a 2-kilobase ..cap alpha..-related transcript. Analysis of cDNA clones corresponding to this transcript established that a genetic element (which they call TEA, for T early ..cap alpha..) located between the ..cap alpha..-chain variable- and joining-region genes had been spliced to the ..cap alpha.. constant region. The TEA transcript is present early in thymocyte ontogeny, and its expression declines during T-cell maturation. More important, the TEA area functions as an active site for rearrangement within the ..cap alpha.. gene locus. Blot hybridization of restriction enzyme-digested DNA with a TEA probe revealed a narrowly limited pattern of rearrangement in polyclonal thymic DNA, surprisingly different from the pattern expected for the mature ..cap alpha.. gene with its complex diversity. These DNA blots also showed that TEA is generally present in the germ-line configuration in cells expressing the ..gamma..delta heterodimeric receptor and is deleted from mature (..cap alpha beta..-expressing) T-lymphocyte tumors and lines. Moreover, the TEA transcript lacked a long open reading frame for protein but instead possessed multiple copies of a repetitive element resembling those utilized in the heavy-chain class switch of the immunoglobulin genes. The temporal nature of the rearrangements and expression detected by TEA suggests that this recombination could mediate a transition between immature (..gamma..delta-expressing) T cells and mature (..cap alpha beta..-expressing) T cells.

  13. Microscopic dose to lung from inhaled alpha emitters in humans

    International Nuclear Information System (INIS)

    Because of the short range of alpha particles in tissue, the degree of uniformity of irradiation of the lung varies greatly depending on the form of the inhaled material. Animal studies have shown that the degree of dose uniformity influences the risk of lung cancer. This study investigates the radiation dose distribution of plutonium in human lung. Numerical maps of tissue configuration and target cell locations are obtained from histological sections of human lung tissue stained to enhance the identification of putative cell types for parenchymal lung cancers, i.e. alveolar type II cells and Clara cells. Monte Carlo simulations are used to obtain dose distribution around individual particles, and these distributions are used to compute dose distribution in volumes of lung tissue. Lung dose is characterised both by the degree of non-uniformity of irradiation and the relative degree of irradiation of all tissue versus the special cells of interest. (authors)

  14. Structure of. cap alpha. -phase in two-phase titanium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Gridnev, V.N.; Ivasishin, O.M.; Svechnikov, V.L. (AN Ukrainskoj SSR, Kiev. Inst. Metallofiziki)

    1982-08-01

    The structure of ..cap alpha..-phase in ..beta..-annealed titanium alloys VT 6 and VT 23 and its changes on heating up to ..cap alpha..+..beta.. ..-->.. ..beta.. transformation temperatures with accelerated cooling is studied. An assumption is made that the observed peculiarities of the residual ..cap alpha..-phase structure in alloys after such treatment are the consequence of the relaxation of interphase stresses resulting from a partial polymorphic transformation while the relaxation mechanism is determined by the alloying degree and initial alloy morphology.

  15. Rapid determination of alpha emitters using Actinide resin.

    Science.gov (United States)

    Navarro, N; Rodriguez, L; Alvarez, A; Sancho, C

    2004-01-01

    The European Commission has recently published the recommended radiological protection criteria for the clearance of building and building rubble from the dismantling of nuclear installations. Radionuclide specific clearance levels for actinides are very low (between 0.1 and 1 Bq g(-1)). The prevalence of natural radionuclides in rubble materials makes the verification of these levels by direct alpha counting impossible. The capability of Actinide resin (Eichrom Industries, Inc.) for extracting plutonium and americium from rubble samples has been tested in this work. Besides a strong affinity for actinides in the tri, tetra and hexavalent oxidation states, this extraction chromatographic resin presents an easy recovery of absorbed radionuclides. The retention capability was evaluated on rubble samples spiked with certified radionuclide standards (239Pu and 241Am). Samples were leached with nitric acid, passed through a chromatographic column containing the resin and the elution fraction was measured by LSC. Actinide retention varies from 60% to 80%. Based on these results, a rapid method for the verification of clearance levels for actinides in rubble samples is proposed. PMID:15177360

  16. Prolixe-prototype reprocessing unit for irradiating wastes contamined with alpha emitters

    International Nuclear Information System (INIS)

    A large number of hot cells are employed for research on nuclear fuel reprocessing and the production of isotope of transuranium elements. These activities generate solid wastes highly contaminated with alpha, beta, gamma emitters. The Prolixe hot cell was built in order to: 1/ reprocess the solid wastes contaminated with alpha, beta, gamma emitters produced in the Radiochemistry building: 2/ produce package wastes storable in shallow-ground disposal sites: 3/ develop a process sufficiently flexible to make it applicable to waste produced in other installations. The process is based on waste leaching after grinding. Depending on the type of wastes the leaching reactant will have a different composition 1/ nitric acid solution for cellulose waste: 2/ nitric solutions containing Ag(II) for other material. The complete process should achieve: 1/ a high waste volume reduction factor: 2/ the production of immobilized waste packages storage in shallow-ground disposal sites: 3/ the recycling of transuranium elements: 4/ the generation of a minimal volume of effluents. This process can be considered as an alternative process to incineration for the reprocessing of solid wastes highly contaminated with alpha, beta, gamma emitters

  17. Radiative Transfer Modeling of Lyman Alpha Emitters. I. Statistics of Spectra and Luminosity

    OpenAIRE

    Zheng, Zheng; Cen, Renyue; Trac, Hy; Miralda-Escude, Jordi

    2009-01-01

    We combine a cosmological reionization simulation with box size of 100Mpc/h on a side and a Monte Carlo Lyman-alpha (Lya) radiative transfer code to model Lyman Alpha Emitters (LAEs) at z~5.7. The model introduces Lya radiative transfer as the single factor for transforming the intrinsic Lya emission properties into the observed ones. Spatial diffusion of Lya photons from radiative transfer results in extended Lya emission and only the central part with high surface brightness can be observed...

  18. The preformation probability inside Alpha-emitters having different ground state spin-parity than daughters

    CERN Document Server

    Seif, W M; Refaie, A I

    2015-01-01

    The ground-state spin and parity of a formed daughter in the radioactive Alpha-emitter is expected to influence the preformation probability of the Alpha and daughter clusters inside it. We investigate the Alpha and daughter preformation probability inside odd-A and doubly-odd radioactive nuclei when the daughter and parent are of different spin and/or parity. We consider only the ground-state to ground-state unfavored decays. This is to extract precise information about the effect of the difference in the ground states spin-parity of the involved nuclei far away any influences from the excitation energy if the decays are coming from isomeric states. The calculations are done for 161 Alpha-emitters, with Z=65-112 and N=84-173, in the framework of the extended cluster model, with WKB penetrability and assault frequency. We used a Hamiltonian energy density scheme based on Skyrme-SLy4 interaction to compute the interaction potential. The Alpha plus cluster preformation probability is extracted from the calculat...

  19. Studying reionization with the next generation of Ly-alpha emitter surveys

    CERN Document Server

    Jensen, Hannes; Iliev, Ilian; Laursen, Peter; Mellema, Garrelt; Zackrisson, Erik

    2014-01-01

    We study the prospects for constraining the ionized fraction of the intergalactic medium (IGM) at $z>6$ with the next generation of large Ly$\\alpha$ emitter surveys. We make predictions for the upcoming Subaru Hyper Suprime-Cam (HSC) Ly$\\alpha$ survey and a hypothetical spectroscopic survey performed with the James Webb Space Telescope (JWST). Considering various scenarios where the observed evolution of the Ly$\\alpha$ luminosity function of Ly$\\alpha$ emitters at $z>6$ is explained partly by an increasingly neutral IGM and partly by intrinsic galaxy evolution, we show how clustering measurements will be able to distinguish between these scenarios. We find that the HSC survey should be able to detect the additional clustering induced by a neutral IGM if the global IGM neutral fraction is greater than $\\sim$20 per cent at $z=6.5$. If measurements of the Ly$\\alpha$ equivalent widths (EWs) are also available, neutral fractions as small as 10 per cent may be detectable by looking for correlation between the EW an...

  20. The nature of z ~ 2.3 Lyman-alpha emitters

    CERN Document Server

    Nilsson, Kim K; Møller, Palle; Möller-Nilsson, Ole; Tapken, Christian; Freudling, Wolfram; Fynbo, Johan P U

    2010-01-01

    We study the multi-wavelength properties of a set of 171 Ly-alpha emitting candidates at redshift z = 2.25 found in the COSMOS field. The candidates are shown to have different properties from those of Ly-alpha emitters found at higher redshift, by fitting the spectral energy distributions (SEDs) using a Monte-Carlo Markov-Chain technique and including nebular emission in the spectra. The dust contents and stellar masses are both higher, with A_V = 0.0 - 2.0 mag and stellar masses in the range log M_* = 9.0 - 11.0 M_sun. Young population ages are well constrained, but older population ages are typically unconstrained. In 40 % of the galaxies only a single, young population of stars is observed. We show that the ages and Ly-alpha fluxes of the best fit galaxies are correlated with their dust properties, with higher dust extinction in younger galaxies. We conclude that the stellar properties of Ly-alpha emitters at z = 2.25 are different from those at higher redshift and that they are very diverse. Ly-alpha sel...

  1. Clustering and lifetime of Lyman Alpha Emitters in the Epoch of Reionization

    CERN Document Server

    Hutter, Anne; Müller, Volker

    2015-01-01

    We calculate Lyman Alpha Emitter (LAE) angular correlation functions (ACFs) at $z\\simeq6.6$ and the fraction of lifetime (for the 100 Myrs preceding $z\\simeq6.6$) galaxies spend as Lyman Break Galaxies (LBGs) with/without Lyman Alpha (Ly\\alpha) emission using a model that combines SPH cosmological simulations (GADGET-2), dust attenuation and a radiative transfer code (pCRASH). The ACFs are a powerful tool that significantly narrows the 3D parameter space allowed by LAE Ly$\\alpha$ and UV luminosity functions (LFs) alone. With this work, we simultaneously constrain the escape fraction of ionizing photons $f_{esc}=0.05-0.5$, the mean fraction of neutral hydrogen in the intergalactic medium (IGM) $\\leq 0.01$ and the dust-dependent ratio of the escape fractions of Ly$\\alpha$ and UV continuum photons $f_\\alpha/f_c=0.6-1.2$. Our results show that reionization has the largest impact on the amplitude of the ACFs, and its imprints are clearly distinguishable from those of $f_{esc}$ and $f_\\alpha/f_c$. We also show that...

  2. Regulation of the synthesis of barley aleurone. cap alpha. -amylase by gibberellic acid and calcium ions

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R.L.; Carbonell, J.

    1984-09-01

    The effects of gibberellic acid (GA/sub 3/) and calcium ions on the production of ..cap alpha..-amylase and acid phosphatase by isolated aleurone layers of barley (Hordeum vulgare L. cv Himalaya) were studied. Aleurone layers not previously exposed to GA/sub 3/ or CA/sup 2 +/ show qualitative and quantitative changes in hydrolase production following incubation in either GA/sub 3/ or CA/sup 2 +/ or both. In cubation in H/sub 2/O or CA/sup 2 +/ results in the production of low levels of ..cap alpha..-amylase or acid phosphatase. The addition of GA/sub 3/ to the incubation medium causes 10- to 20-fold increase in the amounts of these enzymes released from the tissue, and addition of CA/sup 2 +/ at 10 millimolar causes a further 8- to 9-fold increase in ..cap alpha..-amylase release and a 75% increase in phosphatase release. Production of ..cap alpha..-amylase isoenzymes is also modified by the levels of GA/sub 3/ and CA/sup 2 +/ in the incubation medium. ..cap alpha..-amylase 2 is produced under all conditions of incubation, while ..cap alpha..-amylase 1 appears only when layers are incubated in GA/sub 3/ or GA/sub 3/ plus CA/sup 2 +/. The synthesis of ..cap alpha..-amylases 3 and 4 requires the presence of both GA/sub 3/ and CA/sup 2 +/ in the incubation medium. Laurell rocket immunoelectrophoresis shows that two distinct groups of ..cap alpha..-amylase antigens are present in incubation media of aleurone layers incubated with both GA/sub 3/ and CA/sup 2 +/, while only one group of antigens is found in media of layers incubated in GA/sub 3/ alone. Strontium ions can be substituted for CA/sup 2 +/ in increasing hydrolase production, although higher concentrations of Sr/sup 2 +/ are requried for maximal response. We conclude that GA/sub 3/ is required for the production of ..cap alpha..-amylase 1 and that both GA/sub 3/ and either CA/sup 2 +/ or Sr/sup 2 +/ are required for the production of isoenzymes 3 and 4 of barley aleurone ..cap alpha..-amylase. 22 references, 8

  3. A Multiply-Imaged z $\\sim$ 6.3 Lyman Alpha Emitter candidate behind Abell 2261

    CERN Document Server

    Rydberg, Claes-Erik; Zackrisson, Erik; Melinder, Jens; Whalen, Daniel J; Klessen, Ralf S; Gonzalez, Juan; Östlin, Göran; Carollo, Daniela

    2016-01-01

    While the Lyman-$\\alpha$ ($\\mathrm{Ly}\\alpha$) emission line serves as an important tool in the study of galaxies at $z\\lesssim 6$, finding Ly$\\alpha$ emitters (LAE) at significantly higher redshifts has been more challenging, probably because of the increasing neutrality of the intergalactic medium above $z\\sim6$. Galaxies with extremely high rest-frame Ly$\\alpha$ equivalent widths, EW(Ly$\\alpha$) $\\gtrsim 150$ \\AA{}, at $z>6$ are good candidates for Ly$\\alpha$ follow-up observations, and can stand out in multiband imaging surveys because of their unusual colors. We have conducted a photometric search for such objects in the Cluster Lensing And Supernova survey with Hubble (CLASH), and report here the identification of three likely gravitationally-lensed images of a single LAE candidate at $z\\sim6.3$, behind the galaxy cluster Abell 2261($z = 0.225$). In the process, we also measured with Keck/MOSFIRE the first spectroscopic redshift of a multiply-imaged galaxy behind Abell 2261, at $z = 3.337$. This allows ...

  4. Non-linearity between dose and cancer risk for internally deposited alpha emitters in animals

    International Nuclear Information System (INIS)

    The risk of cancer in experimental animals exposed to low doses and dose rates of internally deposited alpha emitting radionuclides was analyzed in 27 animal experiments comprising 78 groups exposed to specific dose levels (dose groups). In these experiments, 3041 animals were exposed to eight different alpha emitters, by injection or by inhalation. Radiation doses ranged from about 60 mGy to more than 7 Gy. There were 1655 control animals. The target organs were the lung and the skeleton. The cancer incidence in exposed groups was compared to that predicted by the Linear No-Threshold Hypothesis (LNTH). In the 3041 exposed animals, 49 cancers were observed, against 83 predicted by the LNTHT. The LNTH appears to be a reliable risk predictor in 11 of the 78 dose groups, but it overestimates the risk in the 67 other dose groups (71 predicted cases, 8 cases observed). No cancer was observed in 53 dose groups, when 23 were predicted by the LNTH. In these 53 dose groups, the probability of not observing a single case of cancer was extremely small. These observations led to the conclusion that, at least in the case of alpha emitters with long physical and biological half-lives, the LNTH is not a good predictor of the risk of cancer. (author)

  5. Limits on the luminosity function of Ly-alpha emitters at z = 7.7

    CERN Document Server

    Hibon, P; Willis, J; Clément, B; Lidman, C; Arnouts, S; Kneib, J -P; Willott, C J; Marmo, C; McCracken, H

    2009-01-01

    The Ly-alpha luminosity function (LF) of high-redshift Ly-alpha emitters (LAEs) is one of the few observables of the re-ionization epoch accessible to date with 8-10 m class telescopes. The evolution with redshift allows one to constrain the evolution of LAEs and their role in re-ionizing the Universe at the end of the Dark Ages. We have performed a narrow-band imaging program at 1.06 microns at the CFHT, targeting Ly-alpha emitters at redshift z ~ 7.7 in the CFHT-LS D1 field. From these observations we have derived a photometric sample of 7 LAE candidates at z ~ 7.7. We derive luminosity functions for the full sample of seven objects and for sub-samples of four objects. If the brightest objects in our sample are real, we infer a luminosity function which would be difficult to reconcile with previous work at lower redshift. More definitive conclusions will require spectroscopic confirmation.

  6. Immuno-vectorization of radioelements emitters of alpha particles: a new therapy in cancerology

    International Nuclear Information System (INIS)

    The radio-immunotherapy is an anti cancerous therapy which consists in vectorising with immuno-specific agents very radio toxic radioelements on tumors or in their environment to destroy them. The first part of this report presents the different characteristics of antibodies as well as their means of production under monoclonal shapes specifically steered against a tumoral antigen of interest. The second part of this report replaces the importance of the immunological vectors in the context of the nuclear medicine. It is notably described that the different methods which allow to radio-label the vector, as well as the different ways of optimization which were envisaged to improve the targeting of radioelements on a tumor. These different developments allow to define the potential place of the alpha radio-immunotherapy in treatments and so re-place the interest of the experimental part. If the radio-immunotherapy, using beta emitters isotopes as the 131iodine or the90yttrium, is today current in anti cancerous therapy, it finds limits because of the disintegration characteristics of the isotopes it uses. Indeed, compared with alpha particles, the beta particles deposit less energy by unit of length in the crossed material.The experimental part of this report aims at studying the feasibility of the coupling between an immunological vector and an alpha emitter isotope.The different tests led on the bismuth 213, the bismuth 212, the lead 212 and the astatine 211 demonstrated that the fixation of these radionuclides was possible. This research theme is strengthened by the construction in Nantes of a cyclotron with high energy ( A.R.R.O.N.A.X.) and the optimization of the obtained promising results should allow a therapeutic use in oncology of the alpha radio-immunotherapy. (N.C.)

  7. Interaction of radiation damage with strain field around. cap alpha. -precipitates in electron-irradiated. beta. -Nb-Zr alloys

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, K.; Kinoshita, C.; Kitajima, S.; Muroo, Y. (Kyushu Univ., Fukuoka (Japan). Dept. of Nuclear Engineering)

    1985-05-01

    The strain field around ..cap alpha..-precipitates (hcp) in the ..beta..-Nb-Zr phase has been evaluated to study its relaxation mechanism during electron irradiation in a high voltage electron microscope. The crystallography of the ..cap alpha..-precipitates is determined to be of Burgers' orientation relationship with the ..beta..-phase. The compressive strain field around the ..cap alpha..-precipitates is detected and determined by use of the strain contrast of electron microscopy and the elastic continuum theory. The relaxation process of the strain field around the ..cap alpha..-precipitates is observed during electron irradiation, and is analyzed in terms of accumulation of vacancies.

  8. Lyman-alpha spectral properties of five newly discovered Lyman continuum emitters

    CERN Document Server

    Verhamme, A; Schaerer, D; Izotov, Y; Worseck, G; Thuan, T X; Guseva, N

    2016-01-01

    We have recently reported the discovery of five low redshift Lyman continuum (LyC) emitters (LCEs, hereafter) with absolute escape fractions fesc(LyC) ranging from 6 to 13%, higher than previously found, and which more than doubles the number of low redshift LCEs.We use these observations to test theoretical predictions about a link between the characteristics of the Lyman-alpha (Lya) line from galaxies and the escape of ionising photons. We analyse the Lya spectra of eight LCEs of the local Universe observed with the Cosmic Origins Spectrograph onboard the Hubble Space Telescope (our five leakers and three galaxies from the litterature), and compare their strengths and shapes to the theoretical criteria and comparison samples of local galaxies: the Lyman Alpha Reference Survey, Lyman Break Analogs, Green Peas, and the high-redshift strong LyC leaker Ion2. Our LCEs are found to be strong Lya emitters, with high equivalent widths, EW(Lya)> 70 {\\AA}, and large Lya escape fractions, fesc(Lya) > 20%. The Lya prof...

  9. Estimates of dose to intraperitoneal micrometastases from alpha and beta emitters in radioimmunotherapy

    International Nuclear Information System (INIS)

    Intraperitoneal metastases from ovarian and other gynecologic tumors are a significant source of treatment failure. In recent years, investigators have used radiolabeled monoclonal antibodies to treat this disease with encouraging results. We have developed a dose calculational technique which generates isodose distributions from intraperitoneally administered alpha and beta particle emitters. In this study we apply the calculations to tissue biopsy samples to determine the adequacy of dose to ovarian micrometastases. Tissue samples from staging biopsies at the time of surgical debulking are scanned to identify small metastases. The patient population studied comprised those with ovarian disease who based on clinical criteria would be considered good candidates for intraperitoneal radioimmunotherapy. The regions of interest (which include the tumor and surface of the peritoneum) are digitized and tumor volumes are contoured. Dose calculations based on the modeling of intraperitoneally administered antibodies radiolabeled with various isotopes is performed and the minimum dose to tumor and normal tissue is assessed. For example, with tumor uptake of 0.1% injected dose per gram of tissue, the surface tumor dose from alpha emitters is up to 45,000 rads. The dose falls to 6000 rads at approximately 40 microns from the peritoneal surface. The surface dose from 20 mCi 90Y administered in 1500 ml saline is up to 10,000 rads, and at a 2-mm depth, approximately 2000 rads. From our calculation dose distribution from radioimmunotherapy varies as a function of physical characteristics of the isotope, absorption of activity, and amount of disease being treated

  10. Pressure phase lines and enthalpies for the. cap alpha. -. beta. and. beta. -liquid transitions in beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Abey, A.

    1984-10-31

    The effect of hydrostatic pressure on the ..cap alpha..-..beta.. and ..beta..-liquid transition temperatures in Be was measured in a gas pressure system. Differential thermal analysis was used in the pressure range from 0.1 MPa to 0.7 GPa. For the ..cap alpha..-..beta.. transition, dT/dP = 43 +- 7 K/GPa; for the ..beta..-liquid transition, dT/dP = 35 +- 7 K/GPa. Although it is possible that large systematic errors may arise from experimental procedures, our results are seriously at odds with those of other investigators. Transition enthalpies for the ..cap alpha..-..beta.. and ..beta..-liquid transitions were 1.9 +- 0.2 and 2.2 +- 0.2 kcal/g.m., respectively, at a pressure of 0.1 MPa.

  11. Biological activity of 1. cap alpha. -hydroxyvitamin D/sub 2/ in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Reeve, L.E.; Schnoes, H.K.; DeLuca, H.F.

    1978-01-01

    The biological activity of 1..cap alpha..-hydroxyvitamin D/sub 2/ has been determined in vitamin D-deficient rats. In the calcification of the rachitic epiphyseal plate, 1..cap alpha..-hydroxyvitamin D/sub 2/ is more active than 25-hydroxyvitamin D/sub 3/, while it is equally active in stimulating intestinal calcium absorption. On the other hand, it is much less active (one-third to one-fifth) than 25-hydroxyvitamin D/sub 3/ in the mobilization of calcium from bone. In both the intestinal and bone responses, 1..cap alpha..-hydroxyvitamin D/sub 2/ (312 pmol) is active in nephrectomized rats while 15-hydroxyvitamin D/sub 3/ is not.

  12. Studies on the atomic and molecular processes produced by alpha emitters in gaseous media using track detection

    International Nuclear Information System (INIS)

    The main purpose of the studies consists in obtaining new and reliable experimental data on certain atomic and molecular physical processes which take place at low speed or/and very low amounts, such as: diffusion, adherence, fallout, etc. of the alpha emitters in gaseous media. By using the track analysis method, most experimental data can be visualized by optical microscopy, so that reliable qualitative and quantitative investigations can be performed. In the first stage, the alpha track method was used. Two plastic detectors were used: CR - 39 (Page, England) and RL - 115 types 1 and 2 (Kodak, France). For these detectors new etching conditions were developed. In the present stage, a calibration of CR - 39 and RL - 115 track detectors for the alpha particles emitted from gaseous radionuclides, particularly for 222 Rn and its alpha descendants, is performed. For this purpose the track detectors were suspended in tight vessels and the following alpha emitter sources were used: - a diuranate source calibrated in uranium prepared in our laboratory; - a calibrated 226 Ra solution; - sources calibrated in 222 Rn and 226 Ra. The amounts and activities of each alpha decay product of these sources are calculated using a radioactive accumulation computation programme UURASE based on the Bateman general equation. The alpha particle ranges were calculated using the TRIM computation programme. In the future stages of this investigation the following studies will be performed: - the diffusion of gaseous alpha emitters; - the sorption of alpha emitter gases and aerosols on different materials; - 222 Rn monitoring in dwelling houses and working places and the implementation of the alpha track method in the National Networks for surveillance of the environmental alpha radioactivity. (authors)

  13. The Brightest Ly$\\alpha$ Emitter: Pop III or Black Hole?

    CERN Document Server

    Pallottini, A; Pacucci, F; Gallerani, S; Salvadori, S; Schneider, R; Schaerer, D; Sobral, D; Matthee, J

    2015-01-01

    CR7 is the brightest $z=6.6 \\, {\\rm Ly}\\alpha$ emitter (LAE) known to date, and spectroscopic follow-up by Sobral et al. (2015) suggests that CR7 might host Population (Pop) III stars. We examine this interpretation using cosmological hydrodynamical simulations. Several simulated galaxies show the same "Pop III wave" pattern observed in CR7. However, to reproduce the extreme CR7 ${\\rm Ly}\\alpha$/HeII1640 line luminosities ($L_{\\rm \\alpha/He II}$) a top-heavy IMF and a massive ($>10^{7}{\\rm M}_{\\odot}$) PopIII burst with age $10^{43.3}{\\rm erg}\\,{\\rm s}^{-1}$ should also host Pop III stars producing an observable $L_{\\rm He II}>10^{42.7}{\\rm erg}\\,{\\rm s}^{-1}$. As an alternate explanation, we explore the possibility that CR7 is instead powered by accretion onto a Direct Collapse Black Hole (DCBH). Our model predicts $L_{\\alpha}$, $L_{\\rm He II}$, and X-ray luminosities that are in agreement with the observations. In any case, the observed properties of CR7 indicate that this galaxy is most likely powered by s...

  14. Transport of. cap alpha. -aminoisobutyric acid into rat parotid after X-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bodner, Lipa

    1989-04-01

    Rat parotid gland exposed to 20 Gy X-irradiation exhibits functional alteration 3 days after exposure. The flow rate of saliva and the uptake of ..cap alpha..-aminoisobutyric acid by the gland was reduced to 50% of values for the control non-irradiated glands. When the same gland was studied in an in vitro system it functioned normally. K/sup +/ release and ..cap alpha..-aminoisobutyric acid uptake by the irradiated dispersed acinar cells was comparable to the control. Transport alteration from the circulatory system into the parotid gland may cause the initial radiation-induced damage.

  15. Determination the total neutron yields of several semiconductor compounds using various alpha emitters

    Science.gov (United States)

    Abdullah, Ramadhan Hayder; Sabr, Barzan Nehmat

    2016-03-01

    In the present work, the cross-sections of (α,n) reactions available in the literature as a function of α-particle energies for light and medium elements have been rearranged for α-particle energies from near threshold up to 10 MeV in steps of (0.050MeV) using the (Excel and Matlab) computer programs. The obtained data were used to calculate the neutron yields (n/106α) using the quick basic-computer program (Simpson Rules). The stopping powers of alpha particle energies from near threshold to 10 MeV for light and medium elements such as (nat.Be,10B,11B,13C,14N,nat.O,nat.F,nat.Mg,nat.Al,29Si,30Si, nat.P and 46.48Ti) have been calculated using the Zeigler formula. The kinetic energies (Tα) and the branching ratios of each α-emitters such as (211Bi, 210Po, 211Po, 215Po, 217At, 218Rn, 219Rn, 222Rn, 224Ra, 226Ra, 215Th, 228Th, 232U, 234U, 236U, 238U, 238Pu, 239Pu, 241Am, 245Es, 252Fm, 254Fm, 256Fm, 257Fm and 257Md) are taken into consideration to calculate the mean kinetic energy . The polynomial expressions were used to fitting the calculated weighted average of neutron yields (n/106α) for natural light and medium elements such as (Be, B, C, N, O, F, Mg, Al, Si, P and Ti) to determine the adopted neutron yields from the best fitting equation with minimum (CHISQ) at mean kinetic energies of various α-emitters. The total neutron yields (n/s/gx/ppmi) of the mentioned natural light and medium elements have been calculated using the adopted neutron yields (n/106α) from the fitting equations at mean kinetic energies of various α-emitters. The total neutron yields (n/s/gα-emitters/gcompounds) of semiconductor compounds such as (AlN, AlP, BN, BP, SiC, TiO2, BeSiN2, MgCN2, MgSiN2 and MgSiP2) have been calculated by mixing (1gram) of compounds with (1gram) of pure α-emitters using the quick basic computer program. The aim of the present work is to constructed and fabricate the neutron sources theoretically

  16. Alpha Particle Emitter Radiolabeled Antibody for Metastatic Cancer: What Can We Learn from Heavy Ion Beam Radiobiology?

    Directory of Open Access Journals (Sweden)

    Hong Song

    2012-06-01

    Full Text Available Alpha-particle emitter labeled monoclonal antibodies are being actively developed for treatment of metastatic cancer due to the high linear energy transfer (LET and the resulting greater biological efficacy of alpha-emitters. Our knowledge of high LET particle radiobiology derives primarily from accelerated heavy ion beam studies. In heavy ion beam therapy of loco-regional tumors, the modulation of steep transition to very high LET peak as the particle approaches the end of its track (known as the Bragg peak enables greater delivery of biologically potent radiation to the deep seated tumors while sparing normal tissues surrounding the tumor with the relatively low LET track segment part of the heavy ion beam. Moreover, fractionation of the heavy ion beam can further enhance the peak-to-plateau relative biological effectiveness (RBE ratio. In contrast, internally delivered alpha particle radiopharmaceutical therapy lack the control of Bragg peak energy deposition and the dose rate is determined by the administered activity, alpha-emitter half-life and biological kinetics of the radiopharmaceutical. The therapeutic ratio of tumor to normal tissue is mainly achieved by tumor specific targeting of the carrier antibody. In this brief overview, we review the radiobiology of high LET radiations learned from ion beam studies and identify the features that are also applicable for the development of alpha-emitter labeled antibodies. The molecular mechanisms underlying DNA double strand break repair response to high LET radiation are also discussed.

  17. Modelling the Evolution of Ly$\\alpha$ Blobs and Ly$\\alpha$ Emitters

    CERN Document Server

    Smailagić, Marijana; Martinovic, Nemanja

    2016-01-01

    In this work we model the observed evolution in comoving number density of Lyman-alpha blobs (LABs) as a function of redshift, and try to find which mechanism of emission is dominant in LAB. Our model calculates LAB emission both from cooling radiation from the intergalactic gas accreting onto galaxies and from star formation (SF). We have used dark matter (DM) cosmological simulation to which we applied empirical recipes for Ly$\\alpha$ emission produced by cooling radiation and SF in every halo. In difference to the previous work, the simulated volume in the DM simulation is large enough to produce an average LABs number density. At a range of redshifts $z\\sim 1-7$ we compare our results with the observed luminosity functions of LABs and LAEs. Our cooling radiation luminosities appeared to be too small to explain LAB luminosities at all redshifts. In contrast, for SF we obtained a good agreement with observed LFs at all redshifts studied. We also discuss uncertainties which could influence the obtained resul...

  18. The VLT LBG Redshift Survey - V. Characterising the z = 3.1 Lyman Alpha Emitter Population

    CERN Document Server

    Bielby, R M; Shanks, T; Francke, H; Crighton, N H M; Bañados, E; González-López, Jorge; Infante, L; Orsi, A

    2016-01-01

    We present a survey of Ly$\\alpha$ emitting galaxies in the fields of the VLT LBG Redshift Survey, incorporating the analysis of narrow band number counts, the rest frame UV luminosity function and the two-point correlation function of Ly$\\alpha$ emitters at $z\\approx3.1$. Our photometric sample consists of 750 LAE candidates, over an area of 1.07 deg$^2$, with estimated equivalent widths of $\\gtrsim65$ \\AA, from 5 fields based on deep Subaru Suprime-Cam imaging data. Added to this we have obtained spectroscopic follow-up observations, which successfully detected Ly$\\alpha$ emission in 35 galaxies. Based on the spectroscopic results, we refined our photometric selection constraints, with the resulting sample having a success rate of $78\\pm18\\%$. We calculate the narrow band number counts for our photometric sample and find these to be consistent with previous studies of LAEs at this redshift. We find the $R$-band continuum luminosity function to be $\\sim10\\times$ lower than the equivalent luminosity function o...

  19. On the Use of Ly-alpha Emitters as Probes of Reionization

    CERN Document Server

    Jensen, Hannes; Mellema, Garrelt; Iliev, Ilian T; Sommer-Larsen, Jesper; Shapiro, Paul R

    2012-01-01

    We use numerical simulations to study the effects of the patchiness of a partly reionized intergalactic medium (IGM) on the observability of Ly-alpha emitters (LAEs) at high redshifts (z ~ 6). We present a new model that divides the Ly-alpha radiative transfer into a (circum-)galactic and an extragalactic (IGM) part, and investigate how the choice of intrinsic line model affects the IGM transmission results. We use our model to study the impact of neutral hydrogen on statistical observables such as the Ly-alpha restframe equivalent width (REW) distribution, the LAE luminosity function and the two-point correlation function. We find that if the observed changes in LAE luminosity functions and equivalent width distributions between z ~ 6 and z ~ 7 are to be explained by an increased IGM neutral fraction alone, we require an extremely late and rapid reionization scenario, where the Universe was ~ 40 % ionized at z = 7, ~ 50 % ionized at z = 6.5 and ~ 100 % ionized at z = 6. This is in conflict with other observa...

  20. Effect of heating rate on temperature of titanium alloy (. cap alpha. +. beta. ). -->. beta. transformaton

    Energy Technology Data Exchange (ETDEWEB)

    Gridnev, V.N.; Ivasishin, O.M.; Markovskij, P.E. (AN Ukrainskoj SSR, Kiev. Inst. Metallofiziki)

    1985-01-01

    The effect of doping of two-phase titaniums alloys and morphology of initial structure on the Tsub(t) temperature shift value of (..cap alpha..+..beta..)..--> beta.. transformation depending on heating rate is investigated. It has been found that the Tsub(t) shift occurs in the strictly determined temperature range depending on chemical alloy composition. The Tsub(t) shift is directly proportional to the Ksub(..beta..) coefficient applied as a quantitative alloying characteristic as well as a dimensional factor equal either to the plate thickness or the ..cap alpha..-phase globule diameter depending on the type of initial structure. In the limits of this temperature range the (..cap alpha..+..beta..)..--> beta..-transformation occurs completely according to the diffusion mechanism. The critical heating rate at which maximum permissible Tsub(t) value is attained and above which its stabilization is observed is determined by the same parameters - the alloy doping degree characterized by the Ksub(..beta..) coefficient and the ..cap alpha..-phase crystal dimensions in the initial structure.

  1. Purification of scintillation cocktails containing the alpha emitters americium and plutonium

    International Nuclear Information System (INIS)

    One efficient way of measuring alpha emitters is by the usage of liquid scintillation counting (LSC). A liquid sample is placed in a vial containing a scintillation cocktail. The alpha particles excite electrons in the surrounding liquid, and when they are de-excited photons are emitted. The photons are detected and the activity can be quantified. LSC has a high efficiency for alpha radiation and is therefore a fast and easy way for measuring alpha emitting samples. One drawback is that it does not differentiate very well between alpha energies; measurements of for example curium and plutonium simultaneously are impossible and demand other techniques. Another drawback is the production of a liquid alpha active waste. In Sweden alpha radioactive waste liquids with an activity over some kBq per waste container cannot be sent for final storage. If, however, the activity of the liquids could be reduced by precipitation of the actinides, it would be possible to send away the liquid samples to municipal incineration. In this work a method for a purification of alpha active scintillation cocktails was developed. The method was first tried on a lab scale, and then scaled up. Until today (March, 2013) more than 20 liters of scintillation liquids have successfully been purified from americium and plutonium at Chalmers University of Technology in Sweden. The four scintillation cocktails used were Emulsifier Safe®, Hionic-Fluor®, Ultima Gold AB® and Ultima Gold XR®. The scintillation cocktails could all be purified from americium with higher yield than 95%. The yield was kept when the liquids were mixed. Also plutonium could be precipitated with a yield over 95% in all cocktails except in Hionic-Fluor® (>55%). However, that liquid in particular could be purified (>95%) by mixing it with the three other cocktails. Up-scaling was performed to a batch size of 6-8 L of scintillation cocktail. In neither the americium nor the plutonium system, adverse effects of increasing the

  2. Early bone changes after incorporation of low quantities of alpha emitters in male rats

    International Nuclear Information System (INIS)

    This work shows the early effects of cancergenic doses of alpha emitters in long bones of rats. The investigations were based on radiographic, morphologic, angiographic, histologic and electronmicroscopic methods. A special method for bone angiography in the rat was elaborated and a new method was developed for measurement of the femur neck-head angle. Numerous disturbances in bone growth and bone structure, in the blood supply of bone and also of the bone building cells were observed. There was a correlation between the severity of the damage and the radiation dose, the spacial distribution of the nuclide and partially the age of the rats. The bone injury due to plutonium was markedly reduced by administration of the chelating agent Zn-DTPA. (orig.)

  3. Radiative Transfer Modeling of Lyman Alpha Emitters: I. Statistics of Spectra and Luminosity

    CERN Document Server

    Zheng, Zheng; Trac, Hy; Miralda-Escude, Jordi

    2009-01-01

    We combine a cosmological reionization simulation with box size of 100Mpc/h on a side and a Monte Carlo Lyman-alpha (Lya) radiative transfer code to model Lyman Alpha Emitters (LAEs) at z~5.7. The model introduces Lya radiative transfer as the single factor for transforming the intrinsic Lya emission properties into the observed ones. Spatial diffusion of Lya photons from radiative transfer results in extended Lya emission and only the central part with high surface brightness can be observed. Because of radiative transfer, the appearance of LAEs depends on density and velocity structures in circumgalactic and intergalactic media as well as the viewing angle, which leads to a broad distribution of apparent (observed) Lya luminosity for a given intrinsic Lya luminosity. Radiative transfer also causes frequency diffusion of Lya photons. The resultant Lya line is asymmetric with a red tail. The peak of the Lya line shifts towards longer wavelength and the shift is anti-correlated with the apparent to intrinsic L...

  4. Exploring the nature of the Lyman-$\\alpha$ emitter CR7

    CERN Document Server

    Hartwig, Tilman; Magg, Mattis; Bromm, Volker; Klessen, Ralf S; Glover, Simon C O; Whalen, Daniel J; Pellegrini, Eric W; Volonteri, Marta

    2015-01-01

    CR7 is the brightest Lyman-$\\alpha$ emitter observed at $z>6$, which shows very strong Lyman-$\\alpha$ and HeII 1640 \\AA\\ line luminosities, but no metal line emission. Previous studies suggest that CR7 hosts either young primordial stars with a total stellar mass of $\\sim 10^7\\,\\mathrm{M}_\\odot$ or a black hole of $\\sim 10^6\\,\\mathrm{M}_\\odot$. Here, we explore different formation scenarios for CR7 with a semianalytical model, based on the random sampling of dark matter merger trees. We find that primordial stars cannot account for the observed line luminosities because of their short lifetimes and because of early metal enrichment. Black holes that are the remnants of the first stars are either not massive enough, or reside in metal-polluted haloes, ruling out this possible explanation of CR7. Our models instead suggest that direct collapse black holes, which form in metal-free haloes exposed to large Lyman-Werner fluxes, are more likely the origin of CR7. However, this result is derived under optimistic ass...

  5. Agonist-promoted desensitization and phosphorylation of. cap alpha. /sub 1/-adrenergic receptors coupled to stimulation of phosphatidylinositol metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Leeb-Lundberg, L.M.F.; Cotecchia, S.; Caron, M.G.; Lefkowitz, R.J.

    1986-03-05

    In the DDT/sub 1/ MF-2 hamster vas deferens smooth muscle cell line the ..cap alpha../sub 1/-adrenergic receptor (..cap alpha../sub 1/-AR) agonist norepinephrine (NE) promotes rapid attenuation of ..cap alpha../sub 1/-AR-mediated phosphatidylinositol (PI) metabolism which is paralleled by rapid phosphorylation of the ..cap alpha../sub 1/-AR. Cells were labeled by incubation with /sup 32/P/sub i/. Coincubation with NE (100 ..mu..M) significantly increases the rate of /sup 32/P-labeling of both PI and phosphatidic acid. Pretreatment of cells with 100 ..mu..M NE (in the presence of 1 ..mu..M propranolol to prevent ..beta..-AR interactions) results in a drastic attenuation of the NE response on PI metabolism. ..cap alpha../sub 1/-AR from labeled cells can be solubilized and purified by affinity chromatography on Affigel-A55414 and wheat germ agglutinin agarose chromatography. SDS-PAGE of purified ..cap alpha../sub 1/-AR shows a NE-promoted increase in phosphorylation of the M/sub r/ 80K ligand binding peptide. Stoichiometry of phosphorylation increases from approx. 1 mol phosphate/mol ..cap alpha../sub 1/-AR in the basal condition to approx. 2.5 after NE treatment. Both desensitization and phosphorylation are rapid being maximal within 10-20 min of agonist exposure. These results together with previous findings that phorbol esters promote rapid ..cap alpha../sub 1/-AR uncoupling and phosphorylation suggest that receptor phosphorylation is an important mechanism of regulation of ..cap alpha../sub 1/-AR receptor responsiveness.

  6. Radiation electromagnetic effect in germanium crystals under high-energy. cap alpha. -particle irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kikoin, I.K.; Babichenko, V.S.; Kikoin, L.I.; Lazarev, S.D.; Rzhanov, A.E.; Filippov, V.I.

    1984-05-01

    Results of experimental investigation into radiation electromagnetic effect (REM) in samples of germanium crystals under approximately 40 MeV ..cap alpha..-particle irradiation in a cyclotron are presented. A high level of excitation, volumetric character of generation of non-equilibrium carriers and formation of defects as well as the form of their spatial distribution are shown to result in some peculiarities of the EMF of the REM effect on the particle flux, fluence and sample parameters. Agreement of theoretical calculations, conducted with account of specificity of ..cap alpha..-particle interaction with a crystal, and experimental data is obtained. It is revealed that the REM effect can be applied in obtaining data on spatial distribution of non-equilibrium carrier concentrations along the particle trajectory in the crystal.

  7. Radiation-electromagnetic effect in germanium crystals irradiated with high-energy. cap alpha. particles

    Energy Technology Data Exchange (ETDEWEB)

    Kikoin, I.K.; Babichenko, V.S.; Kikoin, L.I.; Lazarev, S.D.; Rzhanov, A.E.; Filippov, V.I.

    1984-05-01

    An experimental investigation was made of the radiation-electromagnetic effect in germanium crystals irradiated in a cyclotron with ..cap alpha.. particles of energies up to 40 MeV. The high excitation rate, the bulk nature of generation of nonequilibrium carriers and defects, and their spatial distributions gave rise to several special features in the dependence of the emf due to the radiation-electromagnetic effect on the particle flux, fluence, and parameters of samples. Theoretical calculations carried out allowing for the specific nature of the interaction of ..cap alpha.. particles with crystals agreed well with the experimental results. The radiation-electromagnetic effect could be used to obtain information on the nature of the spatial distribution of the density of nonequilibrium carriers along the trajectory of a particle in a crystal.

  8. Effect of temperature on interatomic distances in pyroelectric. cap alpha. -LiIO/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Coquet, E.; Crettez, J.M. (Laboratoire d' Optique du Reseau Cristallin, Faculte des Sciences, Dijon, France); Pannetier, J.; Bouillot, J. (Institut Max von Laue - Paul Langevin, 38 - Grenoble (France)); Damien, J.C. (Lille-1 Univ., 59 - Villeneuve-d' Ascq (France))

    1983-08-01

    The crystal structure of ..cap alpha..-LiIO/sub 3/ (space group P6/sub 3/) has been refined from neutron and X-ray diffraction data at different temperatures between room temperature and 525 K. The Li atom is well located even at temperatures close to the ..cap alpha.. ..-->.. ..gamma.. phase transition and its thermal parameters do not exhibit any anomalous behaviour. The thermal expansion is analysed in terms of IO/sub 3/-group rotations and expansion of LiO/sub 6/ octahedra; the role of the iodine lone pair in the packing of iodate structures is discussed. The spontaneous polarization is calculated on the basis of a simple point-charge model and the calculated pyroelectric coefficient P/sub 3/ is found to be in fair agreement with the experimental value.

  9. Factorization of the fragmentation cross sections in relativistic pA and. cap alpha. A interactions

    Energy Technology Data Exchange (ETDEWEB)

    Abashidze, L.I.; Avdeichikov, V.V.; Beznogikh, G.G.; Bogatin, V.I.; Budilov, V.A.; Gorshkov, N.L.; Zlomanchuk, Y.; Zhidkov, N.K.; Lozhkin, O.V.; Mruvchinski, S.

    1985-08-01

    We have experimentally demonstrated the factorization of the cross sections for production of the isotopes /sup 3//sup ,//sup 4/He with kinetic energy T> or approx. =100 MeV emitted at an angle 90/sup 0/ in the lab from the nuclei C, Cu, and Au in bombardment by ..cap alpha.. particles with energy 3.33 GeV/nucleon and by protons with energy 6.6 GeV.

  10. Exploiting 21cm - Ly$\\alpha$ emitter synergies: constraints on reionization

    CERN Document Server

    Hutter, Anne; Müller, Volker; Trott, Cathryn

    2016-01-01

    We couple a $z \\simeq 6.6$ hydrodynamical simulation (GADGET-2) with a radiative transfer code (pCRASH) and a dust model to simultaneously obtain the 21cm emission from the spin-flip transition of neutral hydrogen (HI) as well as the sub-population of galaxies visible as Lyman Alpha Emitters (LAEs). Cross-correlating 21cm data with the underlying galaxy population, and especially the subset visible as LAEs, our aim is to constrain both the average intergalactic medium (IGM) ionization state ($\\langle \\chi_{HI} \\rangle$) and the reionization topology (outside-in versus inside-out). We find that LAEs occupy the densest and most-ionized regions resulting in a very strong anti-correlation between the LAEs and the 21cm emission. Within errors, a 1000h SKA-LOW1 - Subaru Hyper Suprime Cam experiment can provide exquisite constraints on $\\langle \\chi_{HI} \\rangle$, allowing us to distinguish between IGM ionization levels of 50%, 25%, 10% and fully ionized at scales $\\leq 10$ comoving Mpc. Our results support the insi...

  11. Evolution in the properties of Lyman-alpha emitters from redshifts z ~ 3 to z ~ 2

    CERN Document Server

    Nilsson, Kim K; Moeller, Palle; Freudling, Wolfram; Fynbo, Johan P U; Meisenheimer, Klaus; Laursen, Peter; Oestlin, Goeran

    2008-01-01

    Context: Narrow-band surveys for Ly-alpha emitters (LAEs) is a powerful tool in detecting high, and very high, redshift galaxies. Even though samples are growing at redshifts z = 3 - 6, the nature of these galaxies is still poorly known. Aims: To study the properties of z = 2.25 LAEs and compare those with the properties of z > 3 LAEs. Methods: We present narrow-band imaging made with the MPG/ESO 2.2m telescope with the WFI detector. We have made a selection for emission-line objects and find 170 candidate typical LAEs and 17 candidates which we regard as high UV-transmission LAEs. We have derived the magnitudes of these objects in 8 bands from u* to Ks, and studied if they have X-ray and/or radio counterparts. Results: We show that there has been significant evolution in the properties of LAEs between redshift z ~ 3 and z = 2.25. The spread in spectral energy distributions (SEDs) at the lower redshift is larger and we detect a significant AGN contribution in the sample. The distribution of the equivalent wid...

  12. Accumulation of glycation products in. cap alpha. -H pig lens crystallin and its bearing to diabetic cataract genesis

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, P.; Cabezas-Cerrato, J.

    1988-01-01

    The incorporation of /sup 11/C-glucose in native pig crystalline by in vitro incubation was found, after subsequent dialysis, to affect all 5 classes of crystallin separated by Sepharose CL-6B column chromatography. Though the radioactivity of the ..cap alpha..-H fraction was three times greater than that of any of the others, autoradiographs of SDS-PAGE gels showed /sup 11/C-glucose adducts to be present in all soluble protein subunits, without there being any evidence of preferential glycation of the ..cap alpha..-H subunits. The concentration of stable glycation products in the ..cap alpha..-H chromatographic fraction of soluble crystallins is suggested to be due the addition of glycated material to this fraction as result of glycation-induced hyperaggregation, and not because the ..cap alpha..-H subunits were especially susceptible to glycation.

  13. Critical review for the determination of the minimum detectable activity (MDA) of alpha-emitter radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Different criteria for the calculation of the Minimum Detectable Activity (MDA) of an alpha emitter in environmental levels are reviewed in this report. Practical examples of its application to previously analyzed samples are shown. The authors propose a criteria based on prior calculations that applies to the radiochemical activities performed in the laboratory. The calculation procedure has been discussed with scientist from other laboratories in order to establish a general criteria to calculate the MDA

  14. Determination of the M-matrix in d-. cap alpha. elastic scattering from a complete set of experiments

    Energy Technology Data Exchange (ETDEWEB)

    Elsener, K.; Grueebler, W.; Sperisen, F.; Ghazi-Wakili, K.; Koenig, V.; Schmelzbach, P.A.; Vuaridel, B.; Bittcher, M.; Singy, D.; Ulbricht, J.

    1988-05-02

    Six polarization transfer coefficients of the d-..cap alpha.. elastic scattering have been measured at an incident deuteron energy of 11.9 MeV and a scattering angle theta/sub lab/ = 37.3/sup 0/. Together with earlier data on cross section and analyzing powers, a complete set of measurements allows to deduce the d-..cap alpha.. M-matrix directly from experiment.

  15. FIRST SPECTROSCOPIC EVIDENCE FOR HIGH IONIZATION STATE AND LOW OXYGEN ABUNDANCE IN Ly{alpha} EMITTERS ,

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kimihiko; Shimasaku, Kazuhiro; Hashimoto, Takuya; Ono, Yoshiaki [Department of Astronomy, Graduate School of Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ouchi, Masami [Kavli Institute for the Physics and Mathematics of the Universe (WPI), University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8583 (Japan); Lee, Janice C., E-mail: nakajima@astron.s.u-tokyo.ac.jp [Space Telescope Science Institute, Baltimore, MD 21218 (United States)

    2013-05-20

    We present results from Keck/NIRSPEC and Magellan/MMIRS follow-up spectroscopy of Ly{alpha} emitters (LAEs) at z = 2.2 identified in our Subaru narrowband survey. We successfully detect H{alpha} emission from seven LAEs, and perform a detailed analysis of six LAEs free from active galactic nucleus activity, two out of which, CDFS-3865 and COSMOS-30679, have [O II] and [O III] line detections. They are the first [O II]-detected LAEs at high-z, and their [O III]/[O II] ratios and R23-indices provide the first simultaneous determinations of ionization parameter and oxygen abundance for LAEs. CDFS-3865 has a very high ionization parameter (q{sub ion}=2.5{sup +1.7}{sub -0.8} Multiplication-Sign 10{sup 8} cm s{sup -1}) and a low oxygen abundance (12+ log (O/H)=7.84{sup +0.24}{sub -0.25}) in contrast with moderate values of other high-z galaxies such as Lyman break galaxies (LBGs). COSMOS-30679 also possesses a relatively high ionization parameter (q{sub ion}=8{sup +10}{sub -4} Multiplication-Sign 10{sup 7} cm s{sup -1}) and a low oxygen abundance (12+ log (O/H)=8.18{sup +0.28}{sub -0.28}). Both LAEs appear to fall below the mass-metallicity relation of z {approx} 2 LBGs. Similarly, a low metallicity of 12 + log (O/H) < 8.4 is independently indicated for typical LAEs from a composite spectrum and the [N II]/H{alpha} index. Such high ionization parameters and low oxygen abundances can be found in local star-forming galaxies, but this extreme local population occupies only {approx}0.06% of the Sloan Digital Sky Survey spectroscopic galaxy sample with a number density {approx}100 times smaller than that of LAEs. With their high ionization parameters and low oxygen abundances, LAEs would represent an early stage of galaxy formation dominated by massive stars in compact star-forming regions. High-q{sub ion} galaxies like LAEs would produce ionizing photons efficiently with a high escape fraction achieved by density-bounded H II regions, which would significantly contribute to

  16. Control of. cap alpha. -amylase mRNA accumulation by gibberellic acid and calcium in barley aleurone layers

    Energy Technology Data Exchange (ETDEWEB)

    Deikman, J.; Jones, R.L.

    1985-01-01

    Pulse-labeling of barley (Hordeum vulgare L. cv Himalaya) aleurone layers incubated for 13 hours in 2.5 micromolar gibberellic acid (GA/sub 3/) with or without 5 millimolar CaCl/sub 2/ shows that ..cap alpha..-amylase isozymes 3 and 4 are not synthesized in vivo in the absence of Ca/sup 2 +/. No difference was observed in ..cap alpha..-amylase mRNA levels between layers incubated for 12 hours in 2.5 micromolar GA/sub 3/ with 5 millimolar CaCl/sub 2/ and layers incubated in GA/sub 3/ alone. RNA isolated from layers incubated for 12 hours in GA/sub 3/ with and without CA/sup 2 +/. A cDNA clone for ..cap alpha..-amylase was isolated and used to measure ..cap alpha..-amylase mRNA levels in aleurone layers incubated in the presence and absence of Ca/sup 2 +/ was translated in vitro and was found to produce the same complement of translation products regardless of the presence of Ca/sup 2 +/ in the incubation medium. Immunoprecipitation of translation products showed that the RNA for ..cap alpha..-amylase synthesized in Ca/sup 2 +/-deprived aleurone layers was translatable. Ca/sup 2 +/ is required for the synthesis of ..cap alpha..-amylase isozymes 3 and 4 at a step after mRNA accumulation and processing.

  17. Alpha-risk or quantification of risks associated with chronic exposure to Alpha emitters; Alpha-risk ou la quantification du risque associe a une exposition chronique aux emeteurs ALPHA

    Energy Technology Data Exchange (ETDEWEB)

    Timarche, M. [Institut de Radioprotection et de Surete Nucleaire, DS, 92 - Fontenay-aux-Roses (France)

    2010-07-15

    This article discusses the results obtained by a European research program on long term health risks associated with a chronic internal contamination by alpha radiation emitters. The researchers outlined that, in the case of an exposure to radon, the lung cancer risk, with respect to the cumulative dose, progressively reduces once the exposure has stopped. They also notice that this risk is present for smokers as well as for not smokers

  18. Capillary electrophoretic study of thiolated alpha-cyclodextrin-capped gold nanoparticles with tetraalkylammonium ions.

    Science.gov (United States)

    Paau, Man Chin; Lo, Chung Keung; Yang, Xiupei; Choi, Martin M F

    2009-11-27

    Capillary zone electrophoresis (CZE) has been employed to characterize nanometer-sized thiolated alpha-cyclodextrin-capped gold nanoparticles (alpha-CD-S-AuNPs). The addition of tetrabutylammonium (Bu(4)N(+)) ions to the run buffer greatly narrows the migration peak of alpha-CD-S-AuNP. The optimal run buffer was determined to be 10mM Bu(4)N(+) in 30 mM phosphate buffer at pH 12 and an applied voltage of 15 kV. The effect of various tetraalkylammonium ions on the peak width and electrophoretic mobility (mu(e)) of alpha-CD-S-AuNP was studied in detail. Bu(4)N(+) ions assist in inter-linking the alpha-CD-S-AuNPs and narrowing the migration peak in CZE. This observation can be explained by the fact that each Bu(4)N(+) ion can simultaneously interact with several hydrophobic cavities of the surface-attached alpha-CDs on AuNPs. The TEM images show that alpha-CD-S-AuNPs with Bu(4)N(+) are linked together but in the absence of Bu(4)N(+), they are more dispersed. The migration mechanism in CZE is based on the formation of inclusion complexes between Bu(4)N(+) and alpha-CD-S-AuNPs which induces changes in the charge-to-size ratio of alpha-CD-S-AuNPs and mu(e). An inverse linear relationship (r(2)>0.998) exists between the mu(e) and size of alpha-CD-S-AuNPs in the core range 1.4-4.1 nm. The CZE analyses are rapid with migration time less than 4 min. A few nanoliters of each of the alpha-CD-S-AuNP samples were injected hydrodynamically at 0.5 psi for 5s. Our work confirms that CZE is an efficient tool for characterizing the sizes of alpha-CD-S-AuNPs using Bu(4)N(+) ions. PMID:19853853

  19. Herschel reveals the obscured star formation in HiZELS H\\alpha\\ emitters at z=1.47

    CERN Document Server

    Ibar, E; Best, P N; Ivison, R J; Smail, I; Arumugam, V; Berta, S; Béthermin, M; Bock, J; Cava, A; Conley, A; Farrah, D; Floc'h, E Le; Lutz, D; Magdis, G; Magnelli, B; Ikarashi, S; Kohno, K; Marsden, G; Oliver, S J; Page, M J; Pozzi, F; Riguccini, L; Schulz, B; Seymour, N; Smith, A J; Symeonidis, M; Wang, L; Wardlow, J; Zemcov, M

    2013-01-01

    We describe the far-infrared (FIR; rest-frame 8--1000\\mu m) properties of a sample of 443 H\\alpha-selected star-forming galaxies in the COSMOS and UDS fields detected by the HiZELS imaging survey. Sources are identified using narrow-band filters in combination with broad-band photometry to uniformly select H\\alpha\\ (and [OII] if available) emitters in a narrow redshift slice at z = 1.47+/-0.02. We use a stacking approach in Spitzer, Herschel (from PEP and HerMES surveys) and AzTEC images to describe their typical FIR properties. We find that HiZELS galaxies with observed H\\alpha\\ luminosities of ~ 10^{8.1-9.1} Lo have bolometric FIR luminosities of typical LIRGs, L_FIR ~ 10^{11.48+/-0.05} Lo. Combining the H\\alpha\\ and FIR luminosities, we derive median SFR = 32+/-5 Mo/yr and H\\alpha\\ extinctions of A(H\\alpha) = 1.0+/-0.2 mag. Perhaps surprisingly, little difference is seen in typical HiZELS extinction levels compared to local star-forming galaxies. We confirm previous empirical stellar mass (M*) to A(H\\alpha...

  20. The BOSS Emission-Line Lens Survey. III. : Strong Lensing of Ly$\\alpha$ Emitters by Individual Galaxies

    CERN Document Server

    Shu, Yiping; Kochanek, Christopher S; Oguri, Masamune; Perez-Fournon, Ismael; Zheng, Zheng; Mao, Shude; Montero-Dorta, Antonio D; Brownstein, Joel R; Marques-Chaves, Rui; Menard, Brice

    2016-01-01

    We introduce the BOSS Emission-Line Lens Survey (BELLS) GALaxy-Ly$\\alpha$ EmitteR sYstems (BELLS GALLERY) Survey, which is a Hubble Space Telescope program to image a sample of galaxy-scale strong gravitational lens candidate systems with high-redshift Ly$\\alpha$ emitters (LAEs) as the background sources. The goal of the BELLS GALLERY Survey is to illuminate dark substructures in galaxy-scale halos by exploiting the small-scale clumpiness of rest-frame far-UV emission in lensed LAEs, and to thereby constrain the slope and normalization of the substructure mass function. In this paper, we describe in detail the spectroscopic strong-lens selection technique, which is based on methods adopted in the previous Sloan Lens ACS (SLACS) Survey, BOSS Emission-Line Lens Survey, and SLACS for the Masses Survey. We present the BELLS GALLERY sample of the 21 highest-quality galaxy-LAE candidates selected from $\\approx 1.4 \\times 10^6$ galaxy spectra in the Baryon Oscillation Spectroscopic Survey (BOSS) of the Sloan Digital...

  1. Involvement of prostaglandins F/sub 2. cap alpha. / and E/sub 1/ with rabbit endometrium

    Energy Technology Data Exchange (ETDEWEB)

    Orlicky, D.J.

    1985-01-01

    Several growth factors and hormones are thought to play a role in the growth control of endometrial cells. The authors have shown that prostaglandin F/sub 2..-->../ (PGF/sub 2..cap alpha../) is a growth factor for primary cultures of rabbit endometrium cultured in chemically-defined serum-free medium and that prostaglandin E/sub 1/ (PGE/sub 1/) antagonizes the PGF/sub 2..-->../ induction of growth. Both (/sup 3/H)PGF/sub 2..cap alpha../ and (/sup 3/H)PGE/sub 1/ bind in a time and temperature dependent, dissociable, saturable and specific manner. The binding of (/sup 3/H)PGF/sub 2..cap alpha../ and (/sup 3/H)PGE/sub 1/ can be both down and up regulated and is enzyme sensitive. PGE /sub 1/ stimulates intracellular cAMP synthesis and accumulation in a time and concentration dependent manner. PGF/sub 2..cap alpha../ probably exerts its effects through an amiloride-sensitive intermediate. Both PGF/sub 2..cap alpha../ and PGE/sub 1/ are constitutively synthesized by these primary cultures, and they have shown this synthesis to be both drug and hormone sensitive. They hypothesize that it is the ratio, rather than the absolute quantities, of PGF/sub 2..cap alpha../ and PGE/sub 1/ which is of more importance in the regulation of endometrial cell growth. Furthermore, they believe this regulation of endometrial growth plays a role in control of proliferation during the decidual response and that a derangement in the ratio of these prostaglandins may lead to either infertility or hyperplasia. The ability of these cultures to synthesize prostaglandins in a hormonally regulatable manner may be of importance in the study of dysmenorrhea and uterine cramping as caused by the myometrial contracting prostaglandin, PGF/sub 2..cap alpha../.

  2. Secondary. cap alpha. -deuterium kinetic isotope effects in solvolyses of ferrocenylmethyl acetate and benzoate in ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Sutic, D. (Univ. of Zagreb, Yugoslavia); Asperger, S.; Borcic, S.

    1982-12-17

    Secondary ..cap alpha..-deuterium kinetic isotope effects (KIE) in solvolyses of ferrocenyldideuteriomethyl acetate and benzoate were determined in 96% (v/v) ethanol, at 25/sup 0/C, as k/sub H//k/sub D/ = 1.24 and 1.26, respectively. The KIEs were also determined in the presence of 0.1 mol dm/sup -3/ lithium perchlorate: the k/sub H//k/ sub D/ values were 1.23 and 1.22 for acetate and benzoate complexes, respectively. The maximum KIE for the C-O bond cleavage of a primary substrate is as large as, or larger than, that of secondary derivatives, which is estimated to be 1.23 per deuterium. The measured KIE of about 12% per D therefore represents a strongly reduced effect relative to its maximum. The solvolyses exhibit ''a special salt effect''. This effect indicates the presence of solvent-separated ion pairs and the return to tight pairs. As the maximum KIE is expected in solvolyses involving transformation of one type of ion pair into another, the strongly reduced ..cap alpha..-D KIE supports the structure involving direct participation of electrons that in the ground state are localized at the iron atom. The alkyl-oxygen cleavage is accompanied by 10-15% acyl-oxygen cleavage.

  3. DNA double strand breaks as predictor of efficacy of the alpha-particle emitter Ac-225 and the electron emitter Lu-177 for somatostatin receptor targeted radiotherapy.

    Directory of Open Access Journals (Sweden)

    Franziska Graf

    Full Text Available RATIONALE: Key biologic effects of the alpha-particle emitter Actinium-225 in comparison to the beta-particle emitter Lutetium-177 labeled somatostatin-analogue DOTATOC in vitro and in vivo were studied to evaluate the significance of γH2AX-foci formation. METHODS: To determine the relative biological effectiveness (RBE between the two isotopes (as - biological consequence of different ionisation-densities along a particle-track, somatostatin expressing AR42J cells were incubated with Ac-225-DOTATOC and Lu-177-DOTATOC up to 48 h and viability was analyzed using the MTT assay. DNA double strand breaks (DSB were quantified by immunofluorescence staining of γH2AX-foci. Cell cycle was analyzed by flow cytometry. In vivo uptake of both radiolabeled somatostatin-analogues into subcutaneously growing AR42J tumors and the number of cells displaying γH2AX-foci were measured. Therapeutic efficacy was assayed by monitoring tumor growth after treatment with activities estimated from in vitro cytotoxicity. RESULTS: Ac-225-DOTATOC resulted in ED50 values of 14 kBq/ml after 48 h, whereas Lu-177-DOTATOC displayed ED50 values of 10 MBq/ml. The number of DSB grew with increasing concentration of Ac-225-DOTATOC and similarly with Lu-177-DOTATOC when applying a factor of 700-fold higher activity compared to Ac-225. Already 24 h after incubation with 2.5-10 kBq/ml, Ac-225-DOTATOC cell-cycle studies showed up to a 60% increase in the percentage of tumor cells in G2/M phase. After 72 h an apoptotic subG1 peak was also detectable. Tumor uptake for both radio peptides at 48 h was identical (7.5%ID/g, though the overall number of cells with γH2AX-foci was higher in tumors treated with 48 kBq Ac-225-DOTATOC compared to tumors treated with 30 MBq Lu-177-DOTATOC (35% vs. 21%. Tumors with a volume of 0.34 ml reached delayed exponential tumor growth after 25 days (44 kBq Ac-225-DOTATOC and after 21 days (34 MBq Lu-177-DOTATOC. CONCLUSION: γH2AX-foci formation, triggered

  4. Lyman-\\alpha{} Emitters in the context of hierarchical galaxy formation: predictions for VLT/MUSE surveys

    CERN Document Server

    Garel, Thibault; Blaizot, Jérémy

    2015-01-01

    The VLT Multi Unit Spectroscopic Explorer (MUSE) integral-field spectrograph can detect Ly\\alpha{} emitters (LAE) in the redshift range $2.8 \\lesssim z \\lesssim 6.7$ in a homogeneous way. Ongoing MUSE surveys will notably probe faint Ly\\alpha{} sources that are usually missed by current narrow-band surveys. We provide quantitative predictions for a typical wedding-cake observing strategy with MUSE based on mock catalogs generated with a semi-analytic model of galaxy formation coupled to numerical Ly\\alpha{} radiation transfer models in gas outflows. We expect $\\approx$ 1500 bright LAEs ($F_{Ly\\alpha}$ $\\gtrsim$ $10^{-17}$ erg s$^{-1}$ cm$^{-2}$) in a typical Shallow Field (SF) survey carried over $\\approx$ 100 arcmin$^2$, and $\\approx$ 2,000 sources as faint as $10^{-18}$ erg s$^{-1}$ cm$^{-2}$ in a Medium-Deep Field (MDF) survey over 10 arcmin$^2$. In a typical Deep Field (DF) survey of 1 arcmin$^2$, we predict that $\\approx$ 500 extremely faint LAEs ($F_{Ly\\alpha}$ $\\gtrsim$ $4 \\times 10^{-19}$ erg s$^{-1}$...

  5. The HETDEX Pilot Survey V: The Physical Origin of Lyman-alpha Emitters Probed by Near-infrared Spectroscopy

    CERN Document Server

    Song, Mimi; Gebhardt, Karl; Hill, Gary J; Drory, Niv; Ashby, Matthew L N; Blanc, Guillermo A; Bridge, Joanna; Chonis, Taylor; Ciardullo, Robin; Fabricius, Maximilian; Fazio, Giovanni G; Gawiser, Eric; Gronwall, Caryl; Hagen, Alex; Huang, Jia-Sheng; Jogee, Shardha; Livermore, Rachael; Salmon, Brett; Schneider, Donald P; Willner, S P; Zeimann, Gregory R

    2014-01-01

    We present the results from a VLT/SINFONI and Keck/NIRSPEC near-infrared spectroscopic survey of 16 Lyman-alpha emitters (LAEs) at $z$ = 2.1 - 2.5 in the COSMOS and GOODS-N fields discovered from the HETDEX Pilot Survey. We detect rest-frame optical nebular lines (H$\\alpha$ and/or [OIII]$\\lambda$5007) for 10 of the LAEs and measure physical properties, including the star formation rate (SFR), gas-phase metallicity, gas-mass fraction, and Ly$\\alpha$ velocity offset. We find that LAEs may lie below the mass-metallicity relation for continuum-selected star-forming galaxies at the same redshift. The LAEs all show velocity shifts of Ly$\\alpha$ relative to the systemic redshift ranging between +85 and +296 km s$^{-1}$ with a mean of +180 km s$^{-1}$. This value is smaller than measured for continuum-selected star-forming galaxies at similar redshifts. The Ly$\\alpha$ velocity offsets show a moderate correlation with the measured star formation rate (2.5$\\sigma$), but no significant correlations are seen with the SFR...

  6. No effect of 5-fluorouracil on the properties of purified. cap alpha. -amylase from barley half-seeds

    Energy Technology Data Exchange (ETDEWEB)

    Rodaway, S.J.; Kende, H.

    1978-01-01

    Amylase has been purified from de-embryonated seeds of barley (Horedeum vulgare L. cv. Betzes) which have been incubated on 10/sup 6/M gibberellic acid (GA/sub 3/) following 3 days of imbibition in buffer. Incubation of the half-seeds in up to 10/sup -2/ M 5-fluorouracil (5-FU) during the entire incubation period, including imbibition, had no effect on any of the following characteristics of purified ..cap alpha..-amylase: thermal stability in the absence of calcium, molecular weight of the enzyme, isozyme composition, specific activity, or the amount of ..cap alpha..-amylase synthesized by the aleurone tissue. The synthesis of rRNA and tRNA was strongly inhibited by 5-FU, indicating that the analog had entered the aleurone cells. These results are not in agreement with those of Carlson (Nature New Biology 237: 39-41 (1972)) who found that treatment of barley aleurone with 10/sup -4/ M 5-FU to the addition of GA/sub 3/ resulted in decreased thermal stability of GA/sub 3/-induced ..cap alpha..-amylase and who interpreted this as evidence that the mRNA for ..cap alpha..-amylase was synthesized during the imbibition of the aleurone tissue and independently of gibberellin action. Results of the present experiments indicate that the thermal stability of highly purified ..cap alpha..-amylase is not altered by treatment of barley half-seeds with 5-FU, and that 5-FU cannot be used as a probe to examine the timing of ..cap alpha..-amylase mRNA synthesis.

  7. Theory of the induction of bone sarcoma by bone-seeking alpha emitters and its application to risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Petojan, I.M.

    1992-06-01

    This work discusses the theory of bone sarcoma induction by bone seeking alpha emitters, which is based strictly on biological considerations relative to the mechanism of radiation-induced carcinogenesis, identification of cells at risk and their location in bone, bone tissue renewal processes and bone cell kinetics with or without radiation exposure. The model is consistent with the data on bone sarcoma incidence human with incorporated long-lived isotopes Ra-226 + Ra-228. Extrapolation of these data to a low intake region of the basis of the developed theoretical approach suggests that the linear ICRP-UNSCEAR model overestimates carciogenic risk at low doses, possibly by a factor of 2-4. The model suggests a linear response of target cells to the initiation effects of alpha irradiation. The non-linear (linear-quadratic) initial part of dose-response curve for osteosarcoma induction is explained quantitatively by a model based on a promoter effect of regenerative hyperplasia resulting from invitation effects of alpha radiation. The maximum overestimation inherent to the model of the low-level risk due to the the dose-dependent promotion factor is estimated using bo{sup +1}/bo, where bo is a model parameter which is proportional to the normal division rate of osteogenic cells in vivo and which can be estimated within the framework of the model. The model provides confirming evidence that, for radiation protection purposes, endosteal cells may be considered the only group of cells at risk of sarcoma induction by low doses of bone-seeking alpha emitters, whereas the role of marrow stromal (osteogenic) cells as target cells is much more significant with increasing intakes, and can become dominating if intake is high enough.

  8. Theory of the induction of bone sarcoma by bone-seeking alpha emitters and its application to risk assessment

    International Nuclear Information System (INIS)

    This work discusses the theory of bone sarcoma induction by bone seeking alpha emitters, which is based strictly on biological considerations relative to the mechanism of radiation-induced carcinogenesis, identification of cells at risk and their location in bone, bone tissue renewal processes and bone cell kinetics with or without radiation exposure. The model is consistent with the data on bone sarcoma incidence human with incorporated long-lived isotopes Ra-226 + Ra-228. Extrapolation of these data to a low intake region of the basis of the developed theoretical approach suggests that the linear ICRP-UNSCEAR model overestimates carciogenic risk at low doses, possibly by a factor of 2-4. The model suggests a linear response of target cells to the initiation effects of alpha irradiation. The non-linear (linear-quadratic) initial part of dose-response curve for osteosarcoma induction is explained quantitatively by a model based on a promoter effect of regenerative hyperplasia resulting from invitation effects of alpha radiation. The maximum overestimation inherent to the model of the low-level risk due to the the dose-dependent promotion factor is estimated using bo+1/bo, where bo is a model parameter which is proportional to the normal division rate of osteogenic cells in vivo and which can be estimated within the framework of the model. The model provides confirming evidence that, for radiation protection purposes, endosteal cells may be considered the only group of cells at risk of sarcoma induction by low doses of bone-seeking alpha emitters, whereas the role of marrow stromal (osteogenic) cells as target cells is much more significant with increasing intakes, and can become dominating if intake is high enough

  9. Similarities and uniqueness of Ly$\\alpha$ emitters among star-forming galaxies at z=2.5

    CERN Document Server

    Shimakawa, Rhythm; Shibuya, Takatoshi; Kashikawa, Nobunari; Tanaka, Ichi; Matsuda, Yuichi; Tadaki, Ken-ichi; Koyama, Yusei; Hayashi, Masao; Suzuki, Tomoko L; Yamamoto, Moegi

    2016-01-01

    We conducted a deep narrow-band imaging survey with the Subaru Prime Focus Camera on the Subaru Telescope and constructed a sample of Ly$\\alpha$ emitters (LAEs) at z=2.53 in the UDS-CANDELS field where a sample of H$\\alpha$ emitters (HAEs) at the same redshift is already obtained from our previous narrow-band observation at NIR. The deep narrow-band and multi broadband data allow us to find LAEs of stellar masses and star-formation rates (SFRs) down to $\\gtrsim$$10^8$ M$_\\odot$ and $\\gtrsim$0.2 M$_\\odot$/yr, respectively. We show that the LAEs are located along the same mass-SFR sequence traced by normal star-forming galaxies such as HAEs, but towards a significantly lower mass regime. Likewise, LAEs seem to share the same mass--size relation with typical star-forming galaxies, except for the massive LAEs, which tend to show significantly compact sizes. We identify a vigorous mass growth in the central part of LAEs: the stellar mass density in the central region of LAEs increases as their total galaxy mass gr...

  10. Conception and optimisation of a new apparatus for the radioactive aerosols alpha emitters measurement in real time

    International Nuclear Information System (INIS)

    The measurement of the atmospheric contaminations due to artificial radioelements alpha emitters (239 Pu, 241 Am, 244 Cm,...) is a very difficult problem to resolve because of the three following reasons: the nature of the radiation to detect; very small activities, which correspond to LDCA; existence in the atmosphere of descendants radon and thoron, which are alpha emitters too. To avoid the drawbacks that the present apparatus present, we have conceived, realised and focused a new apparatus based on the following principals: aerosols collection by gas jet technic on solid state support and measurement in real time under a few millibar pression using a solid detector. First of all, we have tried to make the aerosol collection rate better studying the collector nature and dimension influence, the distance between the collector and the gas jet exit and the air flow. Using different supports, we have shown that the energy resolution is not depending on the support nature, but it depends very much on atmospheric conditions. Direct measurements of the radioactive samples are made by the annular detector insered between the nozzle and the collector. The good resolution, the efficacity and the discrimination of natural and artificial contaminations show off the feasibility of this apparatus

  11. Immuno-vectorization of radioelements emitters of alpha particles: a new therapy in cancerology; Immunovectorisation de radioelements emetteurs de particules alpha: une nouvelle voie therapeutique en cancerologie

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, M

    2007-05-15

    The radio-immunotherapy is an anti cancerous therapy which consists in vectorising with immuno-specific agents very radio toxic radioelements on tumors or in their environment to destroy them. The first part of this report presents the different characteristics of antibodies as well as their means of production under monoclonal shapes specifically steered against a tumoral antigen of interest. The second part of this report replaces the importance of the immunological vectors in the context of the nuclear medicine. It is notably described that the different methods which allow to radio-label the vector, as well as the different ways of optimization which were envisaged to improve the targeting of radioelements on a tumor. These different developments allow to define the potential place of the alpha radio-immunotherapy in treatments and so re-place the interest of the experimental part. If the radio-immunotherapy, using beta emitters isotopes as the {sup 131}iodine or the{sup 90}yttrium, is today current in anti cancerous therapy, it finds limits because of the disintegration characteristics of the isotopes it uses. Indeed, compared with alpha particles, the beta particles deposit less energy by unit of length in the crossed material.The experimental part of this report aims at studying the feasibility of the coupling between an immunological vector and an alpha emitter isotope.The different tests led on the bismuth 213, the bismuth 212, the lead 212 and the astatine 211 demonstrated that the fixation of these radionuclides was possible. This research theme is strengthened by the construction in Nantes of a cyclotron with high energy ( A.R.R.O.N.A.X.) and the optimization of the obtained promising results should allow a therapeutic use in oncology of the alpha radio-immunotherapy. (N.C.)

  12. The luminosity function of Ly-alpha emitters at 2.3 < z < 4.6 from integral-field spectroscopy

    CERN Document Server

    Van Breukelen, C; Venemans, B P; Breukelen, Caroline van; Jarvis, Matt J.; Venemans, Bram P.

    2005-01-01

    We have used VIsible MultiObject Spectrograph Integral-Field Unit (VIMOS-IFU) observations centred on a radio galaxy at z=2.9 to search for Ly-alpha emitters within a comoving volume of ~ 10^4 Mpc^3. We find 14 Ly-alpha emitters with flux > 1.4 x 10^-20 Wm^-2, yielding a comoving space density of 0.0018 +/- 0.0006 Mpc^-3. We fit a Schechter luminosity function which agrees well with previous studies both at similar redshift (z ~ 3.4) and higher redshift (z ~ 5.7). We therefore find no evidence for evolution in the properties of Ly-alpha emitters between 3 < z < 6, although our sample is small. By summing the star-formation rates of the individual Ly-alpha emitters we find a total cosmic star-formation rate density of rho_SFR = 6.7 +/- 0.5 x 10^-3 M_solar yr^-1 Mpc^-3. Integrating over the luminosity function for the combined Ly-alpha surveys at z ~ 3.4 and accounting for the difference in obscuration between the Ly-alpha line and the UV-continuum yields an estimate of rho_SFR ~ 2.2 x 10^-2 M_solar yr^-1...

  13. Clinical use of bone-targeting radiopharmaceuticals with focus on alpha-emitters

    Institute of Scientific and Technical Information of China (English)

    Hinrich; A; Wieder; Michael; Lassmann; Martin; S; Allen-Auerbach; Johannes; Czernin; Ken; Herrmann

    2014-01-01

    Various single or multi-modality therapeutic options are available to treat pain of bone metastasis in patients with prostate cancer.Different radionuclides that emitβ-rays such as 153Samarium and 89Strontium and achieve palliation are commercially available.In contrast toβ-emitters,223Radium as a a-emitter has a short path-length.The advantage of the a-emitter is thus a highly localized biological effect that is caused by radiation induced DNA double-strand breaks and subsequent cell killing and/or limited effectiveness of cellular repair mechanisms.Due to the limited range of the a-particles the bone surface to red bone marrow dose ratio is also lower for 223Radium which is expressed in a lower myelotoxicity.The a emitter 223Radium dichloride is the first radiopharmaceutical that significantly prolongslife in castrate resistant prostate cancer patients with wide-spread bone metastatic disease.In a phaseⅢ,randomized,double-blind,placebo-controlled study 921patients with castration-resistant prostate cancer and bone metastases were randomly assigned.The analysis confirmed the 223Radium survival benefit compared to the placebo(median,14.9 mo vs 11.3 mo;P<0.001).In addition,the treatment results in pain palliation and thus,improved quality of life and a delay of skeletal related events.At the same time the toxicity profile of223Radium was favourable.Since May 2013,223Radium dichloride(Xofigo?)is approved by the US Food and Drug Administration.

  14. Clustering of Ly alpha emitters at z approximate to 4.5

    NARCIS (Netherlands)

    Kovac, Katarina; Somerville, Rachel S.; Rhoads, James E.; Malhotra, Sangeeta; Wang, JunXian

    2007-01-01

    We present the clustering properties of 151 Ly alpha-emitting galaxies at z approximate to 4.5 selected from the Large Area Lyman Alpha (LALA) survey. Our catalog covers an area of 36'; 36' observed with five narrowband filters. We assume that the angular correlation function w(theta) is well repres

  15. Absolute measurements of the alpha-gamma emitters activities by a sum-coincidence method

    International Nuclear Information System (INIS)

    The absolute activity of U-235 contained in a UO2 sample, using a sum-coincidence circuit which selected only the alpha particles which were simultaneous with the well known 184 Kev gamma radiation from Th-231. The alpha particles were detected by ZnS(Ag) scintillator specially designed to show its maximun efficiency for U-235 alpha particles, whereas the gamma radiation was detected by NaI(Tl) scintillation detector. The values obtained for the half-life of U-235 was compared with data from various observers using different experimental techniques. (Author)

  16. A Dual Narrowband Survey for H\\alpha\\ Emitters at z=2.2: Demonstration of the Technique and Constraints on the H\\alpha\\ Luminosity Function

    CERN Document Server

    Lee, Janice C; Spitler, L; Labbe, I; Salim, S; Persson, S E; Ouchi, M; Dale, D; Monson, A; Murphy, D

    2012-01-01

    We present first results from a narrowband imaging program for intermediate redshift emission-line galaxies using the newly commissioned FourStar infrared camera at the 6.5m Magellan telescope. To enable prompt identification of H\\alpha\\ emitters, a pair of custom 1% filters, which sample low-airglow atmospheric windows at 1.19 \\mu m and 2.10 \\mu m, is used to detect both H\\alpha\\ and [OII]\\lambda 3727 emission from the same redshift volume at z=2.2. Initial observations are taken over a 130 arcmin^2 area in the CANDELS-COSMOS field. The exquisite image quality resulting from the combination of the instrument, telescope, and standard site conditions (~0.55" FWHM) allows the 1.19 \\mu m and 2.10 \\mu m data to probe 3\\sigma\\ emission-line depths down to 1.0e-17 erg/s/cm^2 and 1.2e-17 erg/s/cm^2 respectively, in less than 10 hours of integration time in each narrowband. For H\\alpha\\ at z=0.8 and z=2.2, these fluxes correspond to observed star formation rates of ~0.3 and ~4 Msun/yr respectively. We find 122 source...

  17. On the decreasing fraction of Strong Ly$\\alpha$ Emitters around $z$ $\\sim$ $6$-$7$

    CERN Document Server

    Sadoun, Raphael; Miralda-Escudé, Jordi

    2016-01-01

    The fraction of galaxies with strong Ly$\\alpha$ emission has been observed to decrease rapidly with redshift at $z \\ge 6$, after a gradual increase at $z6$. We study this effect by modeling the ionization and Ly$\\alpha$ radiative transfer in the infall region and the IGM around a Ly$\\alpha$ emitting galaxy (LAE), for a spherical halo model with the mean density and radial velocity profiles in the standard $\\Lambda$CDM cosmological scenario. We find that the expected fast increase of the ionizing background intensity toward the end of the reionization epoch implies a rapid evolution of halo infall regions from being self-shielded against the external ionizing background to being mostly ionized. Whereas self-shielded infall regions can scatter the Ly$\\alpha$ photons over a much larger area than the commonly used apertures for observing LAEs, the same infalling gas is no longer optically thick to the Ly$\\alpha$ emission line after it is ionized by the external background, making the Ly$\\alpha$ emission more comp...

  18. An Ultraluminous Lyman Alpha Emitter with a Blue Wing at z=6.6

    CERN Document Server

    Hu, E M; Songaila, A; Barger, A J; Rosenwasser, B; Wold, I

    2016-01-01

    We report the detection of the most luminous high-redshift Lyman Alpha Emitting galaxy (LAE) yet seen, with log L(Ly alpha) = 43.9 ergs/s. The galaxy -- COSMOS Lyman alpha 1, or COLA1 -- was detected in a search for ultra-luminous LAEs with Hyper Suprime-Cam on the Subaru telescope. It was confirmed to lie at z = 6.593 based on a Lyman alpha line detection obtained from followup spectroscopy with the DEIMOS spectrograph on Keck2. COLA1 is the first very high-redshift LAE to show a multi-component Lyman alpha line profile with a blue wing, which suggests that it could lie in a highly ionized region of the intergalactic medium and could have significant infall. If this interpretation is correct, then ultra-luminous LAEs like COLA1 offer a unique opportunity to determine the properties of the HII regions around these galaxies which will help in understanding the ionization of the z ~ 7 intergalactic medium.

  19. Effect of alpha-radiolysis on the dissolution of UO2 doped with alpha emitters under anoxic conditions

    International Nuclear Information System (INIS)

    The α emissions constitute almost entirely the radiation field of spent nuclear fuel after 500 years in a geological repository. In this work the effect of α-radiolysis on the fuel dissolution in the near field was studied. Pellets of UO2 doped with 10% wt. and 0.1% wt. of ''238 Pu (α-emitter) were prepared using a solgel method which provides homogenous distribution of the dopant in the UO2 matrix. The sintered materials were extensively characterized. Static leaching tests on these materials were carried out under anoxic conditions in deaerated water at room temperature. The results show that the uranium release from the matrix increase for the higher dopant concentration. Under the experimental conditions used it was difficult to observe a clear radiolysis effect on dissolution of the material containing 0.1% wt. of ''238 Pu. In order to study the radiation damage due to α decay in the fluorite type lattice of the UO2, the variation of the lattice parameter as a function of time was measured. An increase of the lattice parameter of approx 0,2% was observed after 1,5 months of storage in the UO2 doped with 10% wt. of plutonium. In the case of the UO2 doped with 0,1% wt. ''238 Pu, the lattice parameter did not vary significantly during the same time interval. The possible effects of damage accumulation on UO2 dissolution are discussed. (Author) 7 refs

  20. A Cose Comparison between Observed and modeled Ly{\\alpha} Lines for z ~ 2.2 Lyman Alpha Emitters

    CERN Document Server

    Hashimoto, Takuya; Ouchi, Masami; Shimasaku, Kazuhiro; Schaerer, Daniel; Nakajima, Kimihiko; Shibuya, Takatoshi; Rauch, Michael; Ono, Yoshiaki; Goto, Ryosuke

    2015-01-01

    We present the results of a Lya profile analysis of 12 Lya emitters (LAEs) at z = 2.2 with high-resolution Lya spectra. We find that all 12 objects have a Lya profile with the main peak redward of the systemic redshift defined by nebular lines, and five have a weak, secondary peak blueward of the systemic redshift (blue bump). The average velocity offset of the red main peak (the blue bump, if any) with respect to the systemic redshift is Delta_v_Lya,r = 174+/- 19 km s-1 (Delta_v_Lya,b = -316+/-45 km s-1), which is smaller than (comparable to) that of Lyman-break galaxies (LBGs). The outflow velocities inferred from metal absorption lines in three individual and one stacked spectra are comparable to those of LBGs. The expanding shell model constructed by Verhamme et al. (2006) reproduces not only the Lya profiles but also other observed quantities including the outflow velocity and the FWHM of nebular lines for the non-blue bump objects. On the other hand, the model predicts too high FWHMs of nebular lines fo...

  1. The WUW ML bundle detector A flow through detector for alpha-emitters

    CERN Document Server

    Wenzel, U; Lochny, M

    1999-01-01

    Using conventional laboratory ware, we designed and manufactured a flow through cell for monitoring alpha-bearing solutions. The cell consists of a bundle of thermoplastic, transparent tubes coated with a thin layer of the meltable scintillator MELTILEX sup T sup M at the inner surface. With appropriate energy windows set, the detector can suppress beta-particles to a great extent due to its geometrical dimensions. For pure alpha-solutions, the detection limits are 5 Bq/ml, for composite nuclide mixtures, the detector is capable to monitor the decontamination of medium active waste (<=10 sup 7 Bq/ml) down to 100 Bq alpha/g solution. At a throughput of 1 ml/s, the pressure build-up amounts to approx 2 bar. We have developed a quality control program to ensure the regularity of the individual bundle loops.

  2. Purification of used scintillation liquids containing the alpha emitters americium and plutonium

    International Nuclear Information System (INIS)

    In Sweden, alpha radioactive waste liquids with an activity over some kBq per waste container cannot be sent for final storage. Therefore, in this work, a method for a purification of alpha active scintillation cocktails was developed. Until today (March, 2013) more than 20 L of scintillation liquids have successfully been purified from americium and plutonium. The products of the process are a solid fraction that can be sent to final storage and a practically non-radioactive liquid fraction that can be sent to municipal incineration. (author)

  3. Toxin a from Clostridium difficile binds to rabbit erythrocyte glycolipids with therminal Gal. cap alpha. 1-3Gal. beta. 1-4GlcNaC sequences

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G.F.; Krivan, H.; Wilkins, T.; Smith, D.F.

    1987-05-01

    Toxin A is one of two clostridial toxins implicated as the causative agent of pseudomembranous colitis in patients undergoing postoperative antibiotic therapy. Evidence that the carbohydrate binding determinant for this toxin is a glycoconjugate(s) with non-reducing Gal..cap alpha..1-3Gal..beta..1-4GlcNAc has recently been reported. Specific agglutination of rabbit erythrocytes by Toxin A is inhibited by bovine thyroglobulin and prevented by pretreatment of cells with ..cap alpha..-galactosidase. Total lipid extracts from rabbit erythrocytes were subjected to thin layer chromatography and the chromatogram overlaid with purified /sup 125/I-labeled Toxin A. Two major and several minor toxin-binding glycolipids were detected following autoradiography. The major toxin-binding glycolipids were identified as pentasaccharide- and decasaccharide-ceramides expressing terminal Gal..cap alpha..1-3Gal..beta..1-4GlcNAc sequences. Treatment of the toxin-binding glycolipids with ..cap alpha..-galactosidase abolished binding. Forsmann glycolipid, globoside, Gal..cap alpha..1-4 Gal..beta..1-4Glc-cer, and Gal..cap alpha..1-3Gal..beta..1-4Glc-cer did not bind the toxin. These observations are consistent with the proposed carbohydrate specificity of the toxin for the non-reducing terminal sequence, Gal..cap alpha..1-3Gal..beta..1-4GlcNAc.

  4. RADIOACTIVE POSITRON EMITTER PRODUCTION BY ENERGETIC ALPHA PARTICLES IN SOLAR FLARES

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R. J. [Code 7650, Naval Research Laboratory, Washington, DC 20375 (United States); Kozlovsky, B. [Tel Aviv University, Tel Aviv (Israel); Share, G. H., E-mail: murphy@ssd5.nrl.navy.mil, E-mail: benz@wise.tau.ac.il, E-mail: share@astro.umd.edu [University of Maryland, College Park, MD 20742 (United States)

    2015-01-01

    Measurements of the 0.511 MeV positron-annihilation line from solar flares are used to explore the flare process in general and ion acceleration in particular. In flares, positrons are produced primarily by the decay of radioactive positron-emitting isotopes resulting from nuclear interactions of flare-accelerated ions with ambient solar material. Kozlovsky et al. provided ion-energy-dependent production cross sections for 67 positron emitters evaluated from their threshold energies (some <1 MeV nucleon{sup –1}) to a GeV nucleon{sup –1}, incorporating them into a computer code for calculating positron-emitter production. Adequate cross-section measurements were available for proton reactions, but not for α-particle reactions where only crude estimates were possible. Here we re-evaluate the α-particle cross sections using new measurements and nuclear reaction codes. In typical large gamma-ray line flares, proton reactions dominate positron production, but α-particle reactions will dominate for steeper accelerated-ion spectra because of their relatively low threshold energies. With the accelerated-{sup 3}He reactions added previously, the code is now reliable for calculating positron production from any distribution of accelerated-ion energies, not just those of typical flares. We have made the code available in the online version of the Journal. We investigate which reactions, projectiles, and ion energies contribute to positron production. We calculate ratios of the annihilation-line fluence to fluences of other gamma-ray lines. Such ratios can be used in interpreting flare data and in determining which nuclear radiation is most sensitive for revealing acceleration of low-energy ions at the Sun.

  5. Ly$\\alpha$ Emitters with Very Large Ly$\\alpha$ Equivalent Widths, EW$_{\\rm 0}$(Ly$\\alpha$) $\\simeq 200-400$ \\AA, at $z\\sim 2$

    CERN Document Server

    Hashimoto, Takuya; Shimasaku, Kazuhiro; Schaerer, Daniel; Nakajima, Kimihiko; Shibuya, Takatoshi; Ono, Yoshiaki; Rauch, Michael; Goto, Ryosuke

    2016-01-01

    We present physical properties of spectroscopically confirmed Ly$\\alpha$ emitters (LAEs) with very large rest-frame Ly$\\alpha$ equivalent widths EW$_{\\rm 0}$(Ly$\\alpha$). Although the definition of large EW$_{\\rm 0}$(Ly$\\alpha$) LAEs is usually difficult due to limited statistical and systematic uncertainties, we identify six LAEs selected from $\\sim 3000$ LAEs at $z\\sim 2$ with reliable measurements of EW$_{\\rm 0}$ (Ly$\\alpha$) $\\simeq 200-400$ \\AA\\ given by careful continuum determinations with our deep photometric and spectroscopic data. These large EW$_{\\rm 0}$(Ly$\\alpha$) LAEs do not have signatures of AGN, but notably small stellar masses of $M_{\\rm *} = 10^{7-8}$ $M_{\\rm \\odot}$ and high specific star-formation rates (star formation rate per unit galaxy stellar mass) of $\\sim 100$ Gyr$^{-1}$. These LAEs are characterized by the median values of $L({\\rm Ly\\alpha})=3.7\\times 10^{42}$ erg s$^{-1}$ and $M_{\\rm UV}=-18.0$ as well as the blue UV continuum slope of $\\beta = -2.5\\pm0.2$ and the low dust extinc...

  6. H/sub. cap alpha. / monitors for the Advanced Limiter Test-II (ALT-II) on TEXTOR

    Energy Technology Data Exchange (ETDEWEB)

    Uckan, T.

    1988-05-01

    The H/sub ..cap alpha../ monitor system installed on TEXTOR in conjunction with the Advanced Limiter Test-II (ALT-II) toroidal belt pump limiter is introduced. The monitors are used to study edge particle fluxes and recycling, correlations to confinement properties of core and edge plasma with ALT-II, and also high-power auxiliary heating (/approximately/5 MW) during long-pulse (/approximately/4-s) operation of TEXTOR. A model of the edge particle flux based on the H/sub ..cap alpha../ measurements is presented. The ALT-II experiments are to be carried out in various phases. Here we discuss the results obtained from the monitor system during the initial phase of operations following the installation of the ALT-II limiter, with ohmic heating only. 15 refs., 21 figs.

  7. Determination of arsenic, antimony, and bismuth in silicon using 200 keV. cap alpha. -particle backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Hnatowicz, V.; Kvitek, J. (Ceskoslovenska Akademie Ved, Rez. Ustav Jaderne Fyziky); Krejci, P.; Rybka, V. (Tesla, Prague (Czechoslovakia)); Pelikan, L. (Technical University of Prague (Czechoslovakia). Dept. of Microelectronics)

    1982-11-16

    Concentration profiles of As, Sb, and Bi implanted into Si are studied using backscattering of the 200 keV ..cap alpha..-particles. A conventional ion implanter serves as a source of analyzing beam and the scattered particles are detected using a silicon surface barrier detector. Measured projected ranges R/sub P/ of implanted atoms are found to be in satisfactory agreement with theoretical predictions.

  8. Were progenitors of local L* galaxies Lyman-alpha emitters at high redshift?

    CERN Document Server

    Yajima, Hidenobu; Zhu, Qirong; Abel, Tom; Gronwall, Caryl; Ciardullo, Robin

    2011-01-01

    The Lya emission has been observed from galaxies over a redshift span z ~ 0 - 8.6. However, the link between high-redshift Lya emitters (LAEs) and local galaxies is largely unknown. Here, we investigate the Lya properties of progenitors of a local L^{*} galaxy by combining cosmological hydrodynamic simulations with three-dimensional radiative transfer calculations using the new ART^2 code. We find that the modeled galaxies are Lya bright in redshift z= 0 - 10. In particular, the Lya luminosities of some massive progenitors at z ~ 2 - 6 are close to the observed characteristic L_{Lya}^{*} of LAEs in that redshift range. Both Lya photon escape fraction and line equivalent width increase with redshift. The Lya escape fraction correlates with a number of physical properties of the galaxy, such as mass, SFR and metallicity. We find a "viewing-angle scatter" in which the photon escape depends strongly on the galaxy morphology and orientation. Moreover, we find that high-redshift LAEs show blue-shifted Lya line prof...

  9. Nuclide identification of alpha-emitters by autoradiography in specimen of atomic victims at Nagasaki

    OpenAIRE

    Shichijo, Kazuko; Takatsuji, Toshihiro; Yamamoto, Masayoshi; Nakashima, Masahiro

    2012-01-01

    The explosion of a plutonium Atomic bomb over Nagasaki city in Japan took place at 1102h on August 9, 1945. Radiation dose of A-bomb survivor is practically estimated from external radiation. The alpha particles can be disregarded science they travel only a short distance through air. Plutonium remaining in the soil at Nagasaki after 24yr has been determined in 1971. In the patients subjected to the Atomic bomb there was no evidence of the introduction of radioactive material. We have already...

  10. Effect of the intergalactic environment on the observability of Ly-alpha emitters during reionization

    CERN Document Server

    Iliev, Ilian T; McDonald, Patrick; Mellema, Garrelt; Pen, Ue-Li

    2007-01-01

    Observations of high-redshift Ly-alpha sources are a major tool for studying the high-redshift Universe. We discuss the effect of the reionizing intergalactic medium on the observability of Ly-alpha sources based on large simulations of early structure formation with radiative transfer. This takes into account self-consistently the reionization history, density, velocity and ionization structures and nonlinear source clustering. We find that all fields are highly anisotropic and as a consequence there are very large variations in opacity among the different lines-of-sight. The velocity effects, from both infall and source peculiar velocity are most important for the luminous sources, affecting the line profile and depressing the bright end of the luminosity function. The line profiles are generally asymmetric and the line centers of the luminous sources are always absorbed due to the high density of the local IGM. For both luminous and average sources the damping wing effects are of similar magnitude and rema...

  11. Use of proportional gas scintillator in absolute measurements of alpha-gamma emitter activities

    International Nuclear Information System (INIS)

    The absolute activity of U-235 contained in a U3 O8 sample was measured utilizing a sum-coincidence circuit which selects only the alpha particles which are simultaneous with the 143 KeV and 186 KeV gamma radiations from the Th-231 (product nucleus). The alpha particles were detected by means of a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas atoms, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. The gamma radiations were detected by means of a NaI(Tl) 1'' x 11/2'' scintillation detector. The value obtained for the half-life of U-235 was compared with the data available from various observers which used different experimental techniques. It is shown tht the results, are in excellent agreement with the best international data available on the subject and that, therefore, the sum-coincidence technique constitutes an important method for such measurements. (Author)

  12. Probing the Physical Properties of z=4.5 Lyman Alpha Emitters with Spitzer

    CERN Document Server

    Finkelstein, Keely D; Tilvi, Vithal; Malhotra, Sangeeta; Rhoads, James E; Grogin, Norman A; Pirzkal, Norbert; Dey, Arjun; Jannuzi, Buell T; Mobasher, Bahram; Pakzad, Sabrina; Salmon, Brett; Wang, Junzian

    2015-01-01

    We present the results from a stellar population modeling analysis of a sample of 162 z=4.5, and 14 z=5.7 Lyman alpha emitting galaxies (LAEs) in the Bootes field, using deep Spitzer/IRAC data at 3.6 and 4.5 um from the Spitzer Lyman Alpha Survey, along with Hubble Space Telescope NICMOS and WFC3 imaging at 1.1 and 1.6 um for a subset of the LAEs. This represents one of the largest samples of high-redshift LAEs imaged with Spitzer IRAC. We find that 30/162 (19%) of the z=4.5 LAEs and 9/14 (64%) of the z=5.7 LAEs are detected at >3-sigma in at least one IRAC band. Individual z=4.5 IRAC-detected LAEs have a large range of stellar mass, from 5x10^8 to 10^11 Msol. One-third of the IRAC-detected LAEs have older stellar population ages of 100 Myr - 1 Gyr, while the remainder have ages < 100 Myr. A stacking analysis of IRAC-undetected LAEs shows this population to be primarily low mass (8 -- 20 x 10^8 Msol) and young (64 - 570 Myr). We find a correlation between stellar mass and the dust-corrected ultraviolet-bas...

  13. Alpha-emitter radium-223 in the management of solid tumors: current status and future directions.

    Science.gov (United States)

    Nilsson, Sten

    2014-01-01

    Bone metastases, which are commonly seen in patients with advanced cancers, are a major cause of skeletal events, disability, and death. Radium-223 dichloride (radium-223; Xofigo, formerly Alpharadin), a first-in-class, alpha-emitting radiopharmaceutical that selectively targets bone metastases with high-energy short-range alpha-particles, has been approved for the treatment of patients with castration-resistant prostate cancer (CRPC) with symptomatic bone metastases and no known visceral metastases. Approval is based on results of the randomized phase III trial Alpharadin in Symptomatic Prostate Cancer (ALSYMPCA), in which radium-223 prolonged overall survival and time to first symptomatic skeletal event versus placebo among patients with CRPC with symptomatic bone metastases and was generally well tolerated, with low myelosuppression rates and manageable gastrointestinal adverse events. Long-term follow-up of the ALSYMPCA safety population showed that the incidence of myelosuppression remained low among patients treated with radium-223, with no additional safety issues of acute myelogenous leukemia, myelodysplastic syndrome, aplastic anemia, or primary bone cancer within approximately 1.5 years after treatment. The radium-223 overall survival benefit and low toxicity make it an effective, well-tolerated, and novel treatment option for CRPC and symptomatic bone metastases and opens the possibility of exploring radium-223 in the treatment of bone metastases from other cancers. A phase I clinical trial of patients with breast and prostate cancer with skeletal metastases demonstrated that radium-223 was safe and well tolerated at all therapeutically relevant dosages. Moreover, a phase IIa trial of patients with advanced breast cancer and progressive bone-dominant disease demonstrated that radium-223 targeted areas of increased bone metabolism and showed biologic activity. PMID:24857093

  14. Morphological Properties of Lyman Alpha Emitters at Redshift 4.86 in the COSMOS Field: Clumpy Star Formation or Merger?

    CERN Document Server

    Kobayashi, Masakazu A R; Koekemoer, Anton M; Murayama, Takashi; Taniguchi, Yoshiaki; Kajisawa, Masaru; Shioya, Yasuhiro; Scoville, Nick Z; Nagao, Tohru; Capak, Peter L

    2016-01-01

    We investigate morphological properties of 61 Lyman-alpha emitters (LAEs) at z = 4.86 identified in the COSMOS field, based on Hubble Space Telescope Advanced Camera for Surveys (ACS) imaging data in the F814W-band. Out of the 61 LAEs, we find the ACS counterparts for the 54 LAEs. Eight LAEs show double-component structures with a mean projected separation of 0."63 (~ 4.0 kpc at z = 4.86). Considering the faintness of these ACS sources, we carefully evaluate their morphological properties, that is, size and ellipticity. While some of them are compact and indistinguishable from the PSF half-light radius of 0."07 (~ 0.45 kpc), the others are clearly larger than the PSF size and spatially extended up to 0."3 (~ 1.9 kpc). We find that the ACS sources show a positive correlation between ellipticity and size and that the ACS sources with large size and round shape are absent. Our Monte Carlo simulation suggests that the correlation can be explained by (1) the deformation effects via PSF broadening and shot noise or...

  15. Cross-correlation of the cosmic 21-cm signal and Lyman Alpha Emitters during reionization

    CERN Document Server

    Sobacchi, Emanuele; Greig, Bradley

    2016-01-01

    Interferometry of the cosmic 21-cm signal is set to revolutionize our understanding of the Epoch of Reionization (EoR), eventually providing 3D maps of the early Universe. Initial detections however will be low signal-to-noise, limited by systematics. To confirm a putative 21-cm detection, and check the accuracy of 21-cm data analysis pipelines, it would be very useful to cross-correlate against a genuine cosmological signal. The most promising cosmological signals are wide-field maps of Lyman alpha emitting galaxies (LAEs), expected from the Subaru Hyper-Suprime Cam (HSC) Ultra-Deep field. Here we present estimates of the correlation between LAE maps at z~7 and the 21-cm signal observed by both the Low Frequency Array (LOFAR) and the planned Square Kilometer Array Phase 1 (SKA1). We adopt a systematic approach, varying both: (i) the prescription of assigning LAEs to host halos; and (ii) the large-scale structure of neutral and ionized regions (i.e. EoR morphology). We find that the LAE-21cm cross-correlation...

  16. Impact of Cosmic Variance on the Galaxy-Halo Connection for Lyman-$\\alpha$ Emitters

    CERN Document Server

    Mejia-Restrepo, Julian E

    2016-01-01

    In this paper we study the impact of cosmic variance and observational uncertainties in constraining the mass and occupation fraction, $f_{\\rm occ}$, of dark matter halos hosting Ly-$\\alpha$ Emitting Galaxies (LAEs) at high redshift. To this end, we construct mock catalogs from an N-body simulation to match the typical size of observed fields at $z=3.1$ ($\\sim 1 {\\rm deg^2}$). In our model a dark matter halo with mass in the range $M_{\\rm min}

  17. High-LET alpha-emitters: Radon, lung cancer and smoking

    International Nuclear Information System (INIS)

    The National Academy of Sciences BEIR IV Report deals with the health effects in human populations exposed to internally-deposited alpha-emitting radionuclides and their decay products. Quantitative risk estimates for cancer induction are derived, mainly from analyses of epidemiological data. The Report addresses the health outcomes of exposure to radon and its daughters, primarily lung cancer risks of worker exposure to radon progeny in underground mines and in the general public in indoor domestic environments. An excess relative risk model of lung cancer mortality and exposure to radon progeny is developed; this models the excess risk per Working Level Month in terms of time intervals prior to an attained age, and is dependent on time-since-exposure and age at risk. Risk projections are presented and cover exposure situations of current public health concern. For example, lifetime exposure to 1 WLM y/sup /minus/1/ is estimated to increase the number of deaths due to lung cancer by a factor of about 1.5 over the current rate for both males and females in a population having the current prevalence of cigarette-smoking. Occupational exposure to 4 WLM y/sup /minus/1/ from ages 20 y to 40 y is projected to increase lung cancer deaths by a factor of 1.6 over the current rate of this age cohort in the general population. In all of these cases, most of the increased risk occurs to smokers for whom the risk is up to ten times greater than for non-smokers. 8 refs., 1 tab

  18. Continuous three-dimensional radiation dosimetry in tissue-equivalent phantoms using electron paramagnetic resonance in L-. cap alpha. -alanine

    Energy Technology Data Exchange (ETDEWEB)

    Wielopolski, L.; Maryanski, M.; Ciesielski, B.; Forman, A.; Reinstein, L.E.; Meek, A.G.

    1987-07-01

    A new tissue-equivalent phantom material has been developed which also acts as a dosimeter. The new phantom material has a similar elemental composition to that of soft tissue and has a density 1.1 g/cm/sup 3/. The phantom has an agar-gel base, and contains crystallized L-..cap alpha..-alanine which traps radiation-induced free radicals. Samples from the phantom were analyzed by an electron paramagnetic resonance (EPR) spectrometer and the intensity of the EPR signal was related to the absorbed dose. When calibrated, the phantom material acts as a dosimeter, with applications in radiation therapy.

  19. Diffuse Lyman Alpha Haloes around Lyman Alpha Emitters at z=3: Do Dark Matter Distributions Determine the Lyman Alpha Spatial Extents?

    CERN Document Server

    Matsuda, Y; Hayashino, T; Yamauchi, R; Nakamura, Y; Morimoto, N; Ouchi, M; Ono, Y; Umemura, M; Mori, M

    2012-01-01

    Using stacks of Ly-a images of 2128 Ly-a emitters (LAEs) and 24 protocluster UV-selected galaxies (LBGs) at z=3.1, we examine the surface brightness profiles of Ly-a haloes around high-z galaxies as a function of environment and UV luminosity. We find that the slopes of the Ly-a radial profiles become flatter as the Mpc-scale LAE surface densities increase, but they are almost independent of the central UV luminosities. The characteristic exponential scale lengths of the Ly-a haloes appear to be proportional to the square of the LAE surface densities (r(Lya) \\propto Sigma(LAE)^2). Including the diffuse, extended Ly-a haloes, the rest-frame Ly-a equivalent width of the LAEs in the densest regions approaches EW_0(Lya) ~ 200 A, the maximum value expected for young (< 10^7 yr) galaxies. This suggests that Ly-a photons formed via shock compression by gas outflows or cooling radiation by gravitational gas inflows may partly contribute to illuminate the Ly-a haloes; however, most of their Ly-a luminosity can be e...

  20. Amino acid sequence of phospholipase A/sub 2/-. cap alpha. from the venom of Crotalus adamanteus

    Energy Technology Data Exchange (ETDEWEB)

    Heinrikson, R.L.; Krueger, E.T.; Keim, P.S.

    1977-07-25

    The complete amino acid sequence of Crotalus adamanteus venom phospholipase A/sub 2/-..cap alpha.. has been determined by analysis of the five tryptic peptides from the citraconylated, reduced, and S-(/sup 14/C)carboxamidomethylated enzyme. Earlier studies provided the information necessary to align the tryptic fragments so that secondary cleavage procedures to establish overlaps were unnecessary. The subunit in the phospholipase A/sub 2/-..cap alpha.. dimer is a single polypeptide chain containing 122 amino acids and seven disulfide bonds. The histidine residue implicated in the active site of mammalian phospholipases is at position 47 in the C. adamanteus enzyme and is located in a domain of the molecule which is highly homologous in sequence with corresponding regions of phospholipases from a variety of venom and pancreatic sources. Comparative sequence analysis has revealed insights with regard to the function and evolution of phospholipases A/sub 2/. Primary structural relationships observed among the snake venom enzymes parallel the phylogenetic classification of the venomous reptiles from which they were derived. It is proposed that phospholipases A/sub 2/ of this general type be divided into two groups depending upon the presence or absence of distinctive structural features elucidated in this study.

  1. Electron double ionization cross section in sodium obtained from K. cap alpha. sup(h) hypersatellite spectra

    Energy Technology Data Exchange (ETDEWEB)

    Lahtinen, J.; Keski-Rahkonen, O. (Laboratory of Physics, Helsinki University of Technology, Espoo, Finland)

    1983-05-01

    The K..cap alpha..sup(h) hypersatellite spectrum of Na metal has been measured in electron excitation with voltages from 4 to 25 kV. The spectrum shows lines with initial K/sup -2/ (K..cap alpha../sub 2/sup(h)) and K/sup -2/L/sup -1/ holes. The energies of these lines as well as the K/sup 2/ binding energy have been determined and compared with theoretical calculations. The intensity of the line group with K/sup -2/L/sup -1/ initial configuration relative to the K/sup -2/ group has been measured and found to be in agreement with simple shake-off calculation. The electron double ionization cross section (EDC) of the K-shell has been determined from both thick and thin target measurements using the method developed by Saijonmaa and Keski-Rahkonen, and found to yield equivalent results. The EDC has also been calculated theoretically using classical and quantum mechanical binary encounter approximations as devised by Saijonmaa. Theory reproduces fairly well the magnitude and the atomic number dependence of the EDC whereas the shape of the EDC-curve as function of energy deviates clearly from observed values.

  2. Identification of the brightest Ly\\alpha\\ emitters at z=6.6: implications for the evolution of the luminosity function in the re-ionisation era

    CERN Document Server

    Matthee, Jorryt; Santos, Sérgio; Röttgering, Huub; Darvish, Behnam; Mobasher, Bahram

    2015-01-01

    Using wide field narrow-band surveys, we provide a new measurement of the $z=6.6$ Lyman-$\\alpha$ Emitter (LAE) luminosity function (LF), which constraints the bright end for the first time. We use a combination of archival narrow-band NB921 data in UDS and new NB921 measurements in SA22 and COSMOS/UltraVISTA, all observed with the Subaru telescope, with a total area of $\\sim 5$ deg$^2$. We exclude lower redshift interlopers by using broad-band optical and near-infrared photometry and also exclude three supernovae with data split over multiple epochs. We spectroscopically confirm the two most luminous Ly$\\alpha$ emitters ever found at $z=6.604$ and $6.541$ in the COSMOS field using Keck/DEIMOS and VLT/FORS2. Combining the UDS and COSMOS samples we find no evolution of the bright end of the Ly$\\alpha$ LF between $z=5.7$ and $6.6$, which is supported by spectroscopic follow-up, and conclude that \\emph{Himiko}-like sources are not as rare as previously thought, with number densities of $\\sim 1.5\\times10^{-5}$ Mpc...

  3. Special features of photoelectromagnetic effect and properties of recombination centers in germanium single crystals irradiated by. cap alpha. particles

    Energy Technology Data Exchange (ETDEWEB)

    Babichenko, V.S.; Kikoin, L.I.; Lazarev, S.D.; Rzhanov, A.E.; Filippov, V.I.

    1984-01-01

    Results of studies on a spatial distribution of defects arising in Ge crystals following ..cap alpha..-particle (40 MeV) irradiation are given. The distribution of defects playing the role of recombination centres is shown to produce the definite effect on diffusion-recombination processes in semiconductors. The carrier capture cross section on recombination centres is determined to be sigma approximately 10/sup -15/ cm/sup -2/. A representation of recombination wall appearing in the vicinity of radiation defect concentration peak is introduced. The experimental data are compared with the developed theoretical representations. It is shown that studies on the photoelectromagnetic effect can give information both on the pattern of radiation defect spatial distribution and recombination parameters of irradiated semiconductors.

  4. Characteristics of the photelectromagnetic effect and properties of recombination centers in germanium single crystals irradiated with. cap alpha. particles

    Energy Technology Data Exchange (ETDEWEB)

    Babichenko, V.S.; Kikoin, L.I.; Lazarev, S.D.; Rzhanov, A.E.; Filippov, V.I.

    1984-01-01

    The spatial distribution of defects created in Ge crystals by irradiation with 40-MeV ..cap alpha.. particles was investigated. The distribution of the defects acting as recombination centers had a decisive influence on the diffusion-recombination processes in this semiconductor. The carrier-capture cross section of the recombination centers (sigmaapprox.10/sup -15/ cm/sup 2/) was determined. A concept of a recombination wall, which appeared in the region of a maximum of the radiation defect concentration, was introduced. The experimental data were compared with theoretical representations. This comparison demonstrated that an investigation of the photoelectromagnetic effect could give information both on the nature of the spatial distribution of radiation defects and on the recombination parameters of an irradiated semiconductor.

  5. Angular and velocity distributions of secondary particles emitted in interaction of 3. 6-GeV/nucleon. cap alpha. particles and lead nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Antonenko, V.G.; Vinogradov, A.A.; Galitskii, V.M.; Grigor' yan, Y.I.; Ippolitov, M.S.; Karadzhev, K.V.; Kuz' min, E.A.; Man' ko, V.I.; Ogloblin, A.A.; Paramonov, V.V.; Tsvetkov, A.A.

    1980-04-01

    The technique is described and results presented of measurements of the velocity and angular distributions of pions, protons, and deuterons, and tritons emitted in bombardment of lead nuclei by ..cap alpha.. particles with energy 3.6 GeV/nucleon.

  6. Preliminary studies for the determination of alpha emitters using the gross alpha coprecipitation methods; Estudios preliminara para la determinacion de emisores alfa mediante el metodo de coprecipitationd e alfa total

    Energy Technology Data Exchange (ETDEWEB)

    Suarez-Navarro, J. A.; Pujol, L.; Suarez, J. A.; Pablo, M. A. de

    2003-07-01

    The radiological quality of drinking water in Spain is regulated by Nuclear Security Guideline No, 7.7 (Rev.1) of the Nuclear Security Council (NSC). this guideline establishes the protocol to follow when the radiological level exceeds 0,1 Bq.l''1. When this level is passed, the responsible alpha emitter must be identified; ''210 Po, ''226Ra, ''230Th, ''239Pu, ''224Ra, ''234 U and ''138 U. Activity due to these isotopes is usually determined using alpha spectrometry with semiconductor detectors. This method allows the activity of the alpha emitters to be determined with a good sensitivity. however, it requires long radiochemical isolations and long counting times, so the method is not suitable for rough estimate radiological analysis. In this preliminary work, we present the conditioning of the sample-precipitate that is essential for further radiochemical isolations. (Author) 9 refs.

  7. Effect of trihydroxyoctadecadienoic acids on blood levels of prostaglandins E/sub 2/ and F/sub 2. cap alpha. / and of 5-hydroxyeicosatetraenoic acid in rats with alloxan diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Vartanyan, G.S.; Panosyan, A.G.; Karagezyan, K.G.; Gevorkyan, G.A.

    1986-09-01

    The effect of the trihydroxyoctadecadienoic acids (THODA) fraction on blood levels of some eicosanoids and, in particular, of prostaglandins E/sub 2/ and F/sub 2..cap alpha../(PGE/sub 2/ and PGF/sub 2..cap alpha../), and 5-hydroxyeicosatetraenoic acid (5-HETE) in rats with alloxan diabetes was studied. Concentrations of PGE/sub 2/, PGF/sub 2..cap alpha../, and 5-HETE in peripheral blood plasma were determined by radioimmunoassay. To assess the loss of substances during extraction and chromatography, /sup 3/H/sub 8/-PGE/sub 2/, /sup 3/H/sub 8/-PGF/sub 2..cap alpha.., and /sup 3/H/sub 8/-5-HETE were used. Plasma PGE/sub 2/, PGF/sub 2..cap alpha../, and 5-HETE levels in albino rats with alloxan diabetes and after injection of THODA are shown.

  8. Radioimmunological determination of 5. cap alpha. -pregnane-3,20-dione in the peripheral venous blood of pregnant women showing pathological estriol values and/or HPL values or gestosis, on the basis of the gestational age. Radioimmunologische Bestimmung des 5. cap alpha. -Pregnan-3,20-dion im peripheren Venenblut schwangerer Frauen einer Gruppe mit pathologischen Oestriol- bzw. HPL-Werten und einer Gestosegruppe in Abhaengigkeit vom Gestationsalter

    Energy Technology Data Exchange (ETDEWEB)

    Klemm-Wolfgramm, E.

    1984-01-01

    A modified method of extraction and radioimmunological determination (iodine-125) is described, designed to monitor the concentrations of 5..cap alpha..-pregnandione (5..cap alpha..-DHP) in patients showing a pathological course of pregnancy and to examine the role of 5..cap alpha..-DHP blood levels in the development of gestosis. In this study, a control group was compared with two patient groups showing either (a) gestosis or (b) reduced levels of estriol and/or HPL. (1) In gestosis, the levels of 5..cap alpha..-DHP showed significant reductions that were proportionate to the degree of the disease, whereas decreases in these hormone levels were only observed to a minor extent in connection with pathological values of estriol and/or HPL. (2) The age of the patient had no influence on the hormone concentrations. (3) The increases in 5..cap alpha..-DHP seen in multiparae were only slight and did not attain any statistical significance. (4) No links were established between the concentrations of HPL and 5..cap alpha..-DHP in the maternal plasma and the development of the fetus. (5) Significantly reduced values of 5..cap alpha..-DHP were determined in mothers showing disorders of fetoplacental function (birth weights between 2500 and 3500 g) or gestosis (birth weights above 3500 g). (6) There were no relationships between the maternal serum levels of estriol, HPL and 5..cap alpha..-DHP and the sex of the fetus. (TRV).

  9. Lyman-Alpha Emitter Galaxies at z ~ 2.8 in the Extended Chandra Deep Field-South: I. Tracing the Large-Scale Structure via Lyman-Alpha Imaging

    CERN Document Server

    Zheng, Zhen-Ya; Rhoads, James E; Finkelstein, Steven L; Wang, Jun-Xian; Jiang, Chun-Yan; Cai, Zheng

    2016-01-01

    We present a narrowband survey with three adjacent filters for z=2.8--2.9 Lyman Alpha Emitter (LAE) galaxies in the Extended Chandra Deep Field South (ECDFS), along with spectroscopic followup. With a complete sample of 96 LAEs in the narrowband NB466, we confirm a large-scale structure at z~ 2.8. Compared to the blank field in NB470 and NB475, the LAE density excess in the NB466 field is ~6.0+/-0.8 times the standard deviation expected at z~2.8, assuming a linear bias of 2. The overdense large scale structure in NB466 can be decomposed into 4 protoclusters, whose overdensities are 4.6 - 6.6. These 4 protoclusters are expected to evolve into a Coma-like cluster at z~ 0. In the meanwhile, we investigate the average star-formation rates derived from Ly{\\alpha}, rest-frame UV and X-ray, the Ly{\\alpha} luminosity functions, the Ly{\\alpha} photon densities and their dependence on the environment. We find that the Ly{\\alpha} photon density in the overdense field (NB466) is ~50\\% higher than that in the blank field ...

  10. A High Fraction of Ly-alpha-Emitters Among Galaxies with Extreme Emission Line Ratios at z ~ 2

    CERN Document Server

    Erb, Dawn K; Steidel, Charles C; Strom, Allison L; Rudie, Gwen C; Trainor, Ryan F; Shapley, Alice E; Reddy, Naveen A

    2016-01-01

    Star-forming galaxies form a sequence in the [OIII]/H-beta vs. [NII]/H-alpha diagnostic diagram, with low metallicity, highly ionized galaxies falling in the upper left corner. Drawing from a large sample of UV-selected star-forming galaxies at z~2 with rest-frame optical nebular emission line measurements from Keck-MOSFIRE, we select the extreme ~5% of the galaxies lying in this upper left corner, requiring log([NII]/H-alpha) = 0.75. These cuts identify galaxies with 12 + log(O/H) 20 A. We compare the equivalent width distribution of a sample of 522 UV-selected galaxies at 2.0alpha equivalent width -1 (-4) A, and only 9% of these galaxies qualify as LAEs. The extreme galaxies typically have lower attenuation at Ly-alpha than those in the comparison sample, and have ~50% lower median oxygen abundances. Both factors are likely to facilitate the escape of Ly-alpha: in less dusty galaxies Ly-alpha photons are l...

  11. Drosophila casein kinase I alpha regulates homolog pairing and genome organization by modulating condensin II subunit Cap-H2 levels.

    Directory of Open Access Journals (Sweden)

    Huy Q Nguyen

    Full Text Available The spatial organization of chromosomes within interphase nuclei is important for gene expression and epigenetic inheritance. Although the extent of physical interaction between chromosomes and their degree of compaction varies during development and between different cell-types, it is unclear how regulation of chromosome interactions and compaction relate to spatial organization of genomes. Drosophila is an excellent model system for studying chromosomal interactions including homolog pairing. Recent work has shown that condensin II governs both interphase chromosome compaction and homolog pairing and condensin II activity is controlled by the turnover of its regulatory subunit Cap-H2. Specifically, Cap-H2 is a target of the SCFSlimb E3 ubiquitin-ligase which down-regulates Cap-H2 in order to maintain homologous chromosome pairing, chromosome length and proper nuclear organization. Here, we identify Casein Kinase I alpha (CK1α as an additional negative-regulator of Cap-H2. CK1α-depletion stabilizes Cap-H2 protein and results in an accumulation of Cap-H2 on chromosomes. Similar to Slimb mutation, CK1α depletion in cultured cells, larval salivary gland, and nurse cells results in several condensin II-dependent phenotypes including dispersal of centromeres, interphase chromosome compaction, and chromosome unpairing. Moreover, CK1α loss-of-function mutations dominantly suppress condensin II mutant phenotypes in vivo. Thus, CK1α facilitates Cap-H2 destruction and modulates nuclear organization by attenuating chromatin localized Cap-H2 protein.

  12. CHARACTERIZATION OF THE DISTRIBUTION OF THE Ly{alpha} EMITTERS IN THE 53W002 FIELD AT z = 2.4

    Energy Technology Data Exchange (ETDEWEB)

    Mawatari, K.; Yamada, T.; Nakamura, Y. [Astronomical Institute, Tohoku University, Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8578 (Japan); Hayashino, T. [Research Center for Neutrino Science, Graduate School of Science, Tohoku University, Sendai 980-8578 (Japan); Matsuda, Y., E-mail: mawatari@astr.tohoku.ac.jp [National Astronomical Observatory of Japan, Mitaka, Tokyo 181-8588 (Japan)

    2012-11-10

    We present the results of our wide-field narrowband imaging of the field around the radio galaxy 53W002 at z = 2.390 with Subaru/Suprime-Cam. A custom-made filter, NB413, centered at 4140 A with a width of 83 A is used to observe the 31' Multiplication-Sign 24' area around the radio galaxy. We detected 204 Ly{alpha} emitters (LAEs) at z = 2.4 with a rest-frame equivalent width larger than 25 A to the depth of 26 AB mag (in NB413). The entire LAE population in the 53W002 field has an average number density and distributions of equivalent width and size that are similar to those of other fields at z {approx} 2. We identify a significant high-density region (53W002F-HDR) that spreads over Almost-Equal-To 5' Multiplication-Sign 4' near 53W002, where the LAE number density is nearly four times as large as the average of the entire field. Using the probability distribution function of density fluctuation, we evaluate the rareness probability of 53W002F-HDR to be 0.9{sup +2.4} {sub -0.62}%, which corresponds to a moderately rich structure. No notable environmental dependency at the comoving scale of 10 Mpc is found for the distributions of the Ly{alpha} equivalent width and luminosity in the field. We also detected four Ly{alpha} blobs, one of which is newly discovered. They are all located in the rims of high-density regions. The biased location and unique morphologies in Ly{alpha} suggest that galaxy interaction plays a key role in their formation.

  13. On the absence of appreciable half-life changes in alpha emitters cooled in metals to 1 Kelvin and below

    CERN Document Server

    Stone, N J; Richards, P; Stone, J R; Veskovic, M; Williams, D A

    2006-01-01

    The recent suggestion that dramatic changes may occur in the lifetime of alpha and beta decay when the activity, in a pure metal host, is cooled to a few Kelvin, is examined in the light of published low temperature nuclear orientation (LTNO) experiments, with emphasis here on alpha decay. In LTNO observations are made of the anisotropy of radioactive emissions with respect to an axis of orientation. Correction of data for decay of metallic samples held at temperatures at and below 1 Kelvin for periods of days and longer has been a routine element of LTNO experiments for many years. No evidence for any change of half life on cooling, with an upper level of less than 1%, has been found, in striking contrast to the predicted changes, for alpha decay, of several orders of magnitude. The proposal that such dramatic changes might alleviate problems of disposal of long-lived radioactive waste is shown to be unrealistic.

  14. Radiolytic oxidation of UO{sub 2} pellets doped with alpha-emitters ({sup 238/239}Pu)

    Energy Technology Data Exchange (ETDEWEB)

    Muzeau, B. [Commissariat a l' Energie Atomique, Rhone Valley Research Center DTCD/SECM/LMPA, BP 17 171, 30207 Bagnols-sur-Ceze Cedex (France); Jegou, C. [Commissariat a l' Energie Atomique, Rhone Valley Research Center DTCD/SECM/LMPA, BP 17 171, 30207 Bagnols-sur-Ceze Cedex (France)], E-mail: christophe.jegou@cea.fr; Delaunay, F. [Commissariat a l' Energie Atomique, Valduc Research Center, 21120 Is-sur-Tille (France); Broudic, V. [Commissariat a l' Energie Atomique, Rhone Valley Research Center DTCD/SECM/LMPA, BP 17 171, 30207 Bagnols-sur-Ceze Cedex (France); Brevet, A. [Commissariat a l' Energie Atomique, Valduc Research Center, 21120 Is-sur-Tille (France); Catalette, H. [Electricite de France, Les Renardieres Research Center, Route de Sens Ecuelles, 77250 Moret-sur-Loing (France); Simoni, E. [Institut de Physique Nucleaire, Bat. 100, 91406 Orsay Cedex (France); Corbel, C. [Laboratoire des Solides Irradies, UMR 7642-CNRS-CEA-Ecole Polytechnique, Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2009-01-07

    To assess the impact of alpha radiolysis of water on the oxidative dissolution of UO{sub 2} under anoxic conditions, two series of plutonium-doped samples (specific alpha activity 385 and 18 MBqg{sub UO{sub 2}}{sup -1}) were fabricated, characterized and leached in water of varying complexity (pure water, carbonated water, dissolved hydrogen). Given the very high reactivity of these samples in the presence of air and in order to minimize any prior surface oxidation, a strict experimental protocol was developed based on high-temperature annealing in Ar + 4% H{sub 2} with preleaching cycles. Failure to follow this protocol prevents absolute quantification of oxidation of the UO{sub 2} surface by water radiolysis in solutions. Preoxidation of the pellet surface can lead to uranium release in solution that is dependent on the alpha particle flux, revealing initial oxidation by radiolysis in air including potential traces of water. This makes difficult the accurate quantification of the radiolytic oxidation in water solutions. Controlling the initial surface condition of the samples finally allowed us to demonstrate that radiolytic oxidation in water-saturated media is governed by several threshold effects for which the main parameters are the sample alpha activity and the hydrogen concentration.

  15. cap alpha. -L-iduronidase deficiency in mucopolysaccharidosis type I against a radio-labelled sulfated disaccharide substrate derived from dermatan sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Muller, V.J.; Hopwood, J.J. (Department of Chemical Pathology, The Adelaide Children' s Hospital Inc., North Adelaide, South Australia)

    1984-01-01

    ..cap alpha..-L-Iduronidase activity was assayed by incubation of a radiolabelled disaccharide, O-(..cap alpha..-L-idopyranosyluronic acid)-(1 arrow 3)-2,5 anhydro-D-(1, /sup 3/H)-talitol 4-sulfate (IdoA-anT4S) derived from dermatan sulfate, with homogenates of leucocytes, cultured amniotic cells and skin fibroblasts from normal individuals and patients affected with an ..cap alpha..-L-iduronidase-deficiency disorder (mucopolysaccharidosis type I, MPS I), parents of such patients and patients affected with other mucopolysaccharidoses. The assay clearly distinguished affected homozygotes from normal controls, heterozygotes and other mucopolysaccharidosis types. Preliminary results show that fibroblast homogenates from patients with the MPS I Hurler phenotype were virtually unable to hydrolyse IdoA-anT4S, whereas fibroblast homogenates from a patient with a relatively mild (Scheie) phenotype exhibited a residual activity with Vsub(max) value of 2.5 pmol/min/mg protein and an apparent Ksub(m) of 21 ..mu..mol/l compared to a range of 1020-2105 pmol/min/mg for Vsub(max) and 12-35 ..mu..mol/l for Ksub(m) for fibroblasts from normal controls.

  16. Influence of prostaglandins E/sub 2/ and F/sub 2. cap alpha. / on the zinc transport across rat mid-intestine in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Song, M.K.; Adham, N.F.; Lee, D.B.N.; Carmack, C.R.

    1986-03-05

    Effects of physiological (5.0 ..mu..M) and pharmacological (50 ..mu..M) doses of prostaglandins (PG) E/sub 2/ and F/sub 2..cap alpha../ on the zinc transport rate across rat jejunum mounted on a Ussing Chamber were determined. Zinc transport rate from mucosal to serosal direction was 4.82 +/- 0.81 n moles/hr/cm/sup 2/ whereas the opposite direction was 18.71 +/- 0.96 n moles/hr/cm/sup 2/. When 5.0 ..mu..M or 50 ..mu..M PGE/sub 2/ or PGF/sub 2..cap alpha../ were added into Ringers-Krebs bicarbonate solution containing 3 mM L-histidine and 0.5 mM /sup 65/Zn Cl/sub 2/ to the mucosal side of mucosa, no significant difference in /sup 65/Zn transport rate was observed compared to controls. However, 5.0 ..mu..M PGF/sub 2..cap alpha../ and 50 ..mu..M PGE/sub 2/ significantly inhibited zinc transport from mucosal to serosal direction. When PGs were added to the opposite side of mucosa, only 5.0 ..mu..M PGs significantly inhibited zinc transport from serosal to mucosal direction. Results suggest that PGs act on the inhibition of zinc transport across the basolateral membrane of columnar absorbing cells and that 50 ..mu..M PGE/sub 2/ was the most powerful inhibitor.

  17. An ion guide for the production of a low energy ion beam of daughter products of {alpha}-emitters

    Energy Technology Data Exchange (ETDEWEB)

    Tordoff, B. [Nuclear Physics Group, Schuster Laboratory, Brunswick Street, University of Manchester, Manchester M13 9PL (United Kingdom)]. E-mail: bwt@phys.jyu.fi; Eronen, T. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Elomaa, V.V. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Gulick, S. [Ernest Rutherford Physics Building, McGill University, 3600 rue University, Montreal, QC, H3A 2T8 (Canada); Hager, U. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Karvonen, P. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Kessler, T. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Lee, J. [Ernest Rutherford Physics Building, McGill University, 3600 rue University, Montreal, QC, Canada H3A 2T8 (Canada); Moore, I. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Popov, A. [Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg 188350 (Russian Federation); Rahaman, S. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Rinta-Antila, S. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Sonoda, T. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland); Aystoe, J. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, 40014 Jyvaeskylae (Finland)

    2006-11-15

    A new ion guide has been modeled and tested for the production of a low energy ({approx}40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the {alpha}-decay of a {sup 233}U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electric fields and helium gas flow transport the ions through an exit hole for injection into a mass separator. Ion guide efficiencies for the extraction of {sup 229}Th{sup +} (0.06%), {sup 221}Fr{sup +} (6%) and {sup 217}At{sup +} (6%) beams have been measured. A detailed study of the electric field and gas flow influence on the ion guide efficiency is described for two differing electric field configurations.

  18. An Ion Guide for the Production of a Low Energy Ion Beam of Daughter Products of $\\alpha$-Emitters

    CERN Document Server

    Tordoff, B; Elomaa, V V; Gulick, S; Hager, U; Karvonen, P; Kessler, T; Lee, J; Moore, I; Popov, A; Rahaman, S; Rinta-Antila, S; Sonoda, T; Äystö, J

    2006-01-01

    A new ion guide has been modeled and tested for the production of a low energy ($\\approx$ 40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the $\\alpha$-decay of a $^{233}$U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electric fields and helium gas flow transport the ions through an exit hole for injection into a mass separator. Ion guide efficiencies for the extraction of $^{229}$Th$^{+}$ (0.06%), $^{221}$Fr$^{+}$ (6%), and $^{217}$At$^{+}$ (6%) beams have been measured. A detailed study of the electric field and gas flow influence on the ion guide efficiency is described for two differing electric field configurations.

  19. The Rest-Frame Optical Spectroscopic Properties of Ly$\\alpha$-Emitters at $z\\sim2.5$: The Physical Origins of Strong Ly$\\alpha$ Emission

    CERN Document Server

    Trainor, Ryan F; Steidel, Charles C; Rudie, Gwen C

    2016-01-01

    We present rest-frame optical spectra of 60 faint ($R_{AB}\\sim 27$; $L\\sim0.1 L_*$) Ly$\\alpha$-selected galaxies (LAEs) at $z\\approx2.56$. The average LAE is consistent with the extreme low-metallicity end of the continuum-selected galaxy distribution at $z\\approx2-3$. In particular, the LAEs have extremely high [OIII] $\\lambda$5008/H$\\beta$ ratios (log([OIII]/H$\\beta$) $\\sim$ 0.8) and low [NII] $\\lambda$6585/H$\\alpha$ ratios (log([NII]/H$\\alpha$) $<-1.15$). Using the [OIII] $\\lambda$4364 auroral line, we find that the star-forming regions in faint LAEs are characterized by high electron temperatures ($T_e\\approx1.8\\times10^4$K), low oxygen abundances (12 + log(O/H) $\\approx$ 8.04, $Z_{neb}\\approx0.22Z_\\odot$), and high excitations with respect to more luminous galaxies. Our faintest LAEs have line ratios consistent with even lower metallicities, including six with 12 + log(O/H) $\\approx$ 6.9$-$7.4 ($Z_{neb}\\approx0.02-0.05Z_\\odot$). We interpret these observations in light of new models of stellar evoluti...

  20. 1. cap alpha. ,25-Dihydroxyvitamin D/sub 3/ inhibits. gamma. -interferon synthesis by normal human peripheral blood lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Reichel, H.; Koeffler, H.P.; Tobler, A.; Norman, A.W.

    1987-05-01

    1..cap alpha..,25-Dihydroxyvitamin D/sub 3/ (1,25-(OH)/sub 2/D/sub 3/), the biologically active metabolite of vitamin D/sub 3/, inhibited synthesis of ..gamma..-interferon (IFN-..gamma..) by phytohemagglutinin-activated peripheral blood lymphocytes (PBLs). A significant reduction of IFN-..gamma.. protein levels in PBL culture medium was achieved with a physiologic 1,25-(OH)/sub 2/D/sub 3/ concentration, 1,25-(OH)/sub 2/D/sub 3/ also inhibited accumulation of IFN-..gamma.. mRNA in activated PBLs in a dose-dependent fashion. The ability of 1,25-(OH)/sub 2/D/sub 3/ to modulate IFN-..gamma.. protein synthesis was unaltered in the presence of high concentrations of recombinant human interleukin 2. The suppression of IFN-..gamma.. synthesis by PBLs was specific for 1,25-(OH)/sub 2/D/sub 3/; the potencies of other vitamin D/sub 3/ metabolites were correlated with their affinities for the cellular 1,25-(OH)/sub 2/D/sub 3/ receptor. The time course of 1,25-(OH)/sub 2/D/sub 3/ receptor expression in phytohemagglutinin-activated PBLs was correlated with the time course of 1,25-(OH)/sub 2/D/sub 3/-mediated inhibition of IFN-..gamma.. synthesis. Finally, the authors examined the effects of 1,25-(OH)/sub 2/D/sub 3/ on the constitutive IFN-..gamma.. production by two human T-lymphocyte lines transformed by human T-lymphotropic virus type I. The cell lines were established from a normal donor (cell line S-LB1) and from a patient with vitamin D-dependent rickets type 2 (cell line Ab-VDR). IFN-..gamma.. synthesis by S-LB1 cells was inhibited in a dose-dependent fashion by 1,25-(OH)/sub 2/D/sub 3/, whereas IFN-..gamma.. synthesis by Ab-VDR cells was not altered by 1,25-(OH)/sub 2/D/sub 3/. The data presented in this study provide evidence for a role of 1,25-(OH)/sub 2/D/sub 3/ in immunoregulation.

  1. Large-scale environment of $z\\sim 5.7$ CIV absorption systems -II. Spectroscopy of Lyman-$\\alpha$ emitters

    CERN Document Server

    Díaz, C Gonzalo; Cooke, Jeff; Koyama, Yusei; Ouchi, Masami

    2014-01-01

    The flow of baryons to and from a galaxy, which is fundamental for galaxy formation and evolution, can be studied with galaxy-metal absorption system pairs. Our search for galaxies around CIV absorption systems at $z\\sim5.7$ showed an excess of photometric Lyman-$\\alpha$ emitter (LAE) candidates in the fields J1030+0524 and J1137+3549. Here we present spectroscopic follow-up of 33 LAEs in both fields. In the first field, three out of the five LAEs within 10$h^{{-}1}$ projected comoving Mpc from the CIV system are within $\\pm500$ km s$^{{-}1}$ from the absorption at $z_{\\text{CIV}}=5.7242\\pm0.0001$. The closest candidate (LAE 103027+052419) is robustly confirmed at $212.8^{+14}_{-0.4}h^{-1}$ physical kpc from the CIV system. In the second field, the LAE sample is selected at a lower redshift ($\\Delta z\\sim0.04$) than the CIV absorption system as a result of the filter transmission and, thus, do not trace its environment. The observed properties of LAE 103027+052419 indicate that it is near the high-mass end of...

  2. First direct implications for the dust extinction and star formation of typical Ly{\\alpha} emitters from their faint infrared luminosities

    CERN Document Server

    Kusakabe, Haruka; Nakajima, Kimihiko; Ouchi, Masami

    2014-01-01

    Measuring the IR luminosity of galaxies is crucial for reliably deriving their dust extinction and stellar population. By stacking publicly available deep Spitzer/MIPS 24um and Herschel PACS images for 213 z~2.18 Ly alpha Emitters (LAEs) in the GOODS-South, we obtain a strong upper limit to the IR luminosity of typical high-redshift LAEs and constrain the extinction law for the first time. Our 3sigma upper limit L_{TIR} = 1.1 * 10^{10} L_{sun} gives IRX = L_{TIR}/L_{UV} 44%, are both significantly higher than the cosmic averages at the same epoch. We find that the SMC extinction law is consistent with the IRX and the UV slope beta = -1.4^{+0.2}_{-0.2} of our stacked LAE, while the Calzetti law predicts a 3.8 times higher IRX at this beta. SED fitting using the Calzetti law also gives a ~10 times higher SFR than that calculated from the IR and UV luminosities, SFR_{tot}=1.5-3.3 M_{sun}/yr. With the stellar mass 6.3^{+0.8}_{-2.0} *10^8 M_{sun}, our LAEs lie on a lower-mass extrapolation of the star formation ma...

  3. A hard ionizing spectrum in z=3-4 Ly-alpha emitters with intense [OIII] emission: Analogs of galaxies in the reionization era?

    CERN Document Server

    Nakajima, Kimihiko; Iwata, Ikuru; Inoue, Akio; Kusakabe, Haruka; Ouchi, Masami; Robertson, Brant

    2016-01-01

    We present Keck/MOSFIRE spectra of the diagnostic nebular emission lines [OIII]5007,4959, [OII]3727, and H-beta for a sample of 15 redshift z=3.1-3.7 Ly-alpha emitters (LAEs) and Lyman break galaxies (LBGs). In conjunction with spectra from other surveys, we confirm earlier indications that LAEs have a much higher [OIII]/[OII] line ratio than is seen in similar redshift LBGs. By comparing their distributions on a [OIII]/[OII] versus R23 diagram, we demonstrate that this difference cannot arise solely because of their lower metallicities but most likely is due to a harder ionizing spectrum. Using measures of H-beta and recombination theory, we demonstrate, for a subset of our LAEs, that xi_ion - the number of Lyman continuum photons per UV luminosity - is indeed 0.2-0.5 dex larger than for typical LBGs at similar redshifts. Using photoionization models we estimate the effect this would have on both [OIII]/[OII] and R23 and conclude such a hard spectrum can only partially explain such intense line emission. The...

  4. Kiloparsec Mass/Light Offsets in the Galaxy Pair-Lyman-alpha Emitter Lens System SDSS\\,J1011$+$0143

    CERN Document Server

    Shu, Yiping; Moustakas, Leonidas A; Stern, Daniel; Dey, Arjun; Brownstein, Joel R; Burles, Scott; Spinrad, Hyron

    2016-01-01

    We report the discovery of significant mass/light offsets in the strong gravitational lensing system SDSS\\,J1011$+$0143. We use the high-resolution \\textsl{Hubble Space Telescope} (\\textsl{HST}) F555W- and F814W-band imaging and SDSS spectroscopy of this system, which consists of a close galaxy pair with a projected separation of $\\approx 4.2$ kpc at $z_{\\rm lens} \\sim 0.331$ lensing a Lyman-alpha emitter (LAE) at $z_{\\rm source} = 2.701$. Comparisons between the mass peaks inferred from lens models and light peaks from \\textsl{HST} imaging data reveal significant spatial mass/light offsets as large as $(1.72 \\pm 0.24 \\pm 0.34)$ kpc in both filter bands. Such large mass/light offsets, not seen in isolated field lens galaxies and relaxed galaxy groups, may be related to the interactions between the two lens galaxies. The detected mass/light offsets can potentially serve as an important test for the self-interacting dark matter model. However, other mechanisms such as dynamical friction on spatially differently...

  5. No evidence for Population III stars or a Direct Collapse Black Hole in the z = 6.6 Lyman-$\\alpha$ emitter 'CR7'

    CERN Document Server

    Bowler, R A A; Dunlop, J S; McLeod, D J; Stanway, E R; Eldridge, J J; Jarvis, M J

    2016-01-01

    The z = 6.6 Lyman-$\\alpha$ emitter 'CR7' has been claimed to have a Population III-like stellar population, or alternatively, be a candidate Direct Collapse Black Hole (DCBH). In this paper we investigate the evidence for these exotic scenarios using recently available, deeper, optical, near-infrared and mid-infrared imaging. We find strong Spitzer/IRAC detections for the main component of CR7 at 3.6 and 4.5 microns, and show that it has a blue colour ([3.6] - [4.5] $= -1.2\\pm 0.3$). This colour cannot be reproduced by current Pop. III or pristine DCBH models. Instead, the results suggest that the [3.6] band is contaminated by the [OIII]4959,5007 emission line with an implied rest-frame equivalent width of EW_0 (H$\\beta$ + [OIII]) $\\gtrsim 2000$\\AA. Furthermore, we find that new near-infrared data from the UltraVISTA survey supports a weaker He II 1640 emission line than previously measured, with EW_0 $= 40 \\pm 30$\\AA. For the fainter components of CR7 visible in Hubble Space Telescope imaging, we find no evi...

  6. Biochemical studies of mouse brain tubulin: colchicine binding (DEAE-cellulose filter) assay and subunits (. cap alpha. and. beta. ) biosynthesis and degradation (in newborn brain)

    Energy Technology Data Exchange (ETDEWEB)

    Tse, Cek-Fyne

    1978-01-01

    A DEAE-cellulose filter assay, measuring (/sup 3/H)colchicine bound to colchicine binding protein (CBP) absorbed on filter discs, has been modified to include lM sucrose in the incubation medium for complexing colchicine to CBP in samples before applying the samples to filter discs (single point assay). Due to the much greater stability of colchicine binding capacity in the presence of lM sucrose, multiple time-point assays and least squares linear regression analysis were not necessary for accurate determination of CBP in hybrid mouse brain at different stages of development. The highest concentrations of CBP were observed in the 160,000g supernatant and pellet of newborn brain homogenate. Further studies of the modified filter assay documented that the assay has an overall counting efficiency of 27.3%, that DEAE-cellulose filters bind and retain all tubulin in the assay samples, and that one molecule of colchicine binds approximately one molecule of tubulin dimer. Therefore, millimoles of colchicine bound per milligram total protein can be used to calculate tubulin content. With this technique tubulin content of brain supernatant was found to be 11.9% for newborn, and 7.15% for 11 month old mice. Quantitative densitometry was also used to measure mouse brain supernatant actin content for these two stages. In vivo synthesis and degradation rates of tubulin ..cap alpha.. and ..beta.. subunits of two day mouse brain 100,000g supernatant were studied after intracerebral injection of (/sup 3/H)leucine. Quantitative changes of the ratio of tritium specific activities of tubulin ..cap alpha.. and ..beta.. subunits with time were determined. The pattern of change was biphasic. During the first phase the ratio decreased; during the second phase the ratio increased continuously. An interpretation consistent with all the data in this study is that the ..cap alpha.. subunit is synthesized at a more rapid rate than the ..beta.. subunit. (ERB)

  7. /sup 45/Ca efflux for myometrial cells: comparison of the effects of prostaglandin F/sub 2/. cap alpha. (PGF/sub 2/), oxytocin (OT) and arachidonate (A)

    Energy Technology Data Exchange (ETDEWEB)

    Katona, G.; Molnar, M.; Toth, M.; Hertelendy, F.

    1986-03-01

    The aim of this study was to measure PGF/sub 2..cap alpha../-induced Ca/sup 2 +/ release from uterine cells and to compare this to the actions of OT and A. Smooth muscle cells isolated from the uterus (shell gland) of laying hens were cultured for 7 days in M199 plus 10% fetal calf serum. The cells were treated with digitonin (20..mu..M) and preloaded with /sup 45/Ca for 40 min. Addition of PGF/sub 2..cap alpha../ caused a biphasic /sup 45/Ca-efflux. There was a small but significant /sup 45/Ca-release within 30 sec (rapid phase) followed by a larger one within 7 min (slow phase). In comparison, both OT and A stimulated /sup 45/Ca efflux during a single, slow phase. The maximal effect of A was observed at < 7 min, whereas that of OT was slower, peaking after 7 min. Mepacrin, an inhibitor of A release, attenuated the action of OT without having any effect on A promoted /sup 45/Ca-efflux. Indomethacin, an inhibitor of PG synthase, failed to suppress the Ca-releasing effect of A suggesting the A itself or a lipoxygenase product may have been responsible for the observed effects. Moreover, these results provide suggestive evidence that A release is an important step in the action of various uterotonic agents converging on the mobilization of intracellular Ca.

  8. [OIII] emission line as a tracer of star-forming galaxies at high redshifts: Comparison between H$\\alpha$ and [OIII] emitters at $z$=2.23 in HiZELS

    CERN Document Server

    Suzuki, T L; Sobral, D; Khostovan, A A; Hayashi, M; Shimakawa, R; Koyama, Y; Tadaki, K -i; Tanaka, I; Minowa, Y; Yamamoto, M; Smail, I; Best, P N

    2016-01-01

    We investigate the properties of $z$=2.23 H$\\alpha$ and [OIII]$\\lambda$5007 emitters using the narrow-band-selected samples obtained from the High-$z$ Emission Line Survey (HiZELS: Sobral et al. 2013). We construct two samples of the H$\\alpha$ and [OIII] emitters and compare their integrated physical properties. We find that the distribution of stellar masses, dust extinction, star formation rates (SFRs), and specific SFRs, is not statistically different between the two samples. When we separate the full galaxy sample into three subsamples according to the detections of the H$\\alpha$ and/or [OIII] emission lines, most of the sources detected with both H$\\alpha$ and [OIII] show ${\\rm log(sSFR_{UV})}$$\\gtrsim$-9.5. The comparison of the three subsamples suggests that sources with strong [OIII] line emission tend to have the highest star-forming activity out all galaxies that we study. We argue that the [OIII] emission line can be used as a tracer of star-forming galaxies at high redshift, and that it is especia...

  9. Study on the risk of late damage in humans after incorporation of the short-lived alpha emitter Ra-224; Studie zum Risiko von Spaetschaeden beim Menschen nach Inkorporation des kurzlebigen {alpha}-Strahlers Radium-224

    Energy Technology Data Exchange (ETDEWEB)

    Wick, R.R.; Nekolla, E.A.; Kellerer, A.M. [Muenchen Univ. (Germany). Strahlenbiologisches Inst.; Goessner, W. [Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany). Inst. fuer Pathologie

    2003-07-01

    An epidemiological study has been carried out at the GSF - National Research Center for Environment and Health - between 1948 and 1975, on 1460 ankylosing spondylitis (AS) patients. The aim of the study was to ascertain the late health effects suffered by these patients who had received repeated intravenous injections of the short lived {alpha}-emitter {sup 224}Ra. These patients have been followed together with a control group of 1323 ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Causes of death have been ascertained for 842 exposed patients and 861 controls by the end of 2002. In the exposed group there has been a total of 219 malignant diseases and 206 cases among the controls. In particular, we observed 15 cases of leukaemia in the exposure group and 8 cases of leukaemia in the control group. Further subclassification of the leukaemias demonstrated a high increase of myeloid leukaemia in the exposure group (9 cases obs. vs. 2.5 cases exp.), and out of these especially the acute myeloid leukaemias (6 cases observed vs. 1.6 expected), whereas in the control group the observed cases are within the expected range (3 myeloid leukaemias vs. 2.6 cases). Out of these 6 cases of myeloid leukaemia, 3 cases have been observed at doses comparable to those of the currently applied {sup 224}Ra treatment with the preparation SpondylAT {sup registered}, in one case the {sup 224}Ra-dose was the 0.6fold, in another case 1.6fold, whereas in one case the total dose could not be verified exactly. The enhanced leukaemia incidence in our exposed group is in line with results from animal experiments in mice having been injected with bone seeking {alpha}-emitters given at low dose rates. (orig.) [German] Im Rahmen einer epidemiologischen Studie werden im GSF-Forschungszentrum 1460 Bechterew-Patienten beobachtet, die in den Jahren 1948 bis 1975 zur Behandlung ihrer Krankheit wiederholte intravenoese Injektionen von {sup 224}Ra erhalten haben. Daneben

  10. Targeted therapy using alpha emitters

    Science.gov (United States)

    Vaidyanathan, Ganesan; Zalutsky, Michael R.

    1996-10-01

    Radionuclides such as and which decay by the emission of -particles are attractive for certain applications of targeted radiotherapy. The tissue penetration of and -particles is equivalent to only a few cell diameters, offering the possibility of combining cell-specific targeting with radiation of similar range. Unlike the -particles emitted by radionuclides such as and , -particles are radiation of high linear energy transfer and thus greater biological effectiveness. Several approaches have been explored for targeted radiotherapy with - and -labelled substances including colloids, monoclonal antibodies, metabolic precursors, receptor-avid ligands and other lower molecular weight molecules. An additional agent which exemplifies the promise of -emitting radiopharmaceuticals is meta-[]astatobenzylguanidine. The toxicity of this compound under single-cell conditions, determined both by []thymidine incorporation and by limiting dilution clonogenic assays, for human neuroblastoma cells is of the order of 1000 times higher than that of meta-[]iodobenzylguanidine. For meta-[]astatobenzylguanidine, the value was equivalent to only atoms bound per cell. These results suggest that meta-[]astatobenzylguanidine might be valuable for the targeted radiotherapy of micrometastatic neuroblastomas.

  11. Extractive separation of micro amounts of rhenium from molybdenite by quinoline and a modified method of rhenium determination by. cap alpha. -furyl-dioxime

    Energy Technology Data Exchange (ETDEWEB)

    Dorz, D.; Dobrowolski, J. (Politechnika Gdanska (Poland))

    1979-01-01

    The extractive separation of rhenium(7) by quinoline in alkaline solution as well as a modification of the spectrophotometric method for the determination of micro amounts of rhenium in a molybdenite from copper-molybdenum ores from Mongolia, using ..cap alpha..-furyldioxime has been developed. On the basis of the extractive separation method of perrhenate ion by quinoline from alkaline solution, rhenium has been determined in molybdenite. The molybdenite was decomposed by four different methods. Two of these decomposition methods, the fusion of Na/sub 2/O/sub 2/ with NaOH and the sintering of CaO with KMnO/sub 4/ were found as the best ones.

  12. A remarkably high fraction of strong Ly_alpha emitters amongst luminous redshift 6.0

    CERN Document Server

    Curtis-Lake, E; Pearce, H J; Dunlop, J S; Cirasuolo, M; Stark, D P; Almaini, O; Bradshaw, E J; Chuter, R; Foucaud, S; Hartley, W G

    2011-01-01

    We present spectroscopic confirmation of ten highly luminous (L >= 2L*) Lyman alpha emitters in the redshift range 6.01= 6 Lyman break galaxies (LBGs) selected from an area of 0.25 square degrees within the UKIDSS Ultra-deep Survey (UDS). Overall, our high rate of spectroscopic confirmation (>= 71%) and low rate of contamination provides a strong vindication of the photometric redshift analysis used to define the original sample. By considering star-formation rate estimates based on the Ly_alpha and UV continuum luminosity we conclude that our sample is consistent with a Ly_alpha escape fraction of ~25%. Moreover, after careful consideration of the potential uncertainties and biases, we find that 40%-50% of our sample of L >= 2L* galaxies at 6.0= 25 Angs), a fraction which is a factor of ~2 higher than previously reported for L =2 L*) LBGs shows a similarly sharp increase to that observed in their lower-luminosity (L <= L*) counterparts.

  13. Synthesis of biological markers in fossil fuels. 4. C/sub 27/, C/sub 28/, and C/sub 29/ 13. beta. ,17. cap alpha. (H)-diasteranes

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, P.E.; Nelson, D.A.; Watt, D.S.; Reibenspies, J.H.; Anderson, O.P.; Seifert, W.K.; Moldowan, J.M.

    1985-12-27

    The rearrangement of 5-cholestene to (20epsilon)-13(17)-diacholestenes, separation of C-20 epimers, and further reduction provided an unambiguous synthesis of the biomarkers (20R)- and (20S)-13..beta..,17..cap alpha..(H)-diacholestanes. Repetition of this sequence using (24R)-5-campestene or (24R)-5-stigmastene provided the analogous C/sub 28/ and C/sub 29/ diasteranes. 15 references, 1 figure.

  14. Effect of. cap alpha. -tocopherol, butylated-hydroxytoluene and hydroxy-anisole on the activation and binding of aflatoxin B/sub 1/ to macromolecules

    Energy Technology Data Exchange (ETDEWEB)

    Ch' ih, J.J.; Biedrzycka, D.; Devlin, T.M.

    1987-05-01

    The anti-oxidants, ..cap alpha..-tocopherol(TPA), butylated-hydroxy-toluene(BHT) and hydroxyanisole(BHA) inhibit the carcinogenic and toxic effects of a variety of chemical compounds, their effect on aflatoxin B/sub 1/ (AFB/sub 1/) activation and binding was examined utilizing rat liver microsomes and cells. With a NADPH generating system, oxygen, microsomes, (/sup 3/H)-AFB/sub 1/, 2.2 pmoles/h/mg protein was activated and bound to macromolecules. In hepatocytes, 3.4 and 1.4 pmoles of AFB/sub 1/ per 10/sup 6/ cells were taken up and bound to macromolecules, whereas the nucleic acid fraction contained 0.19 pmoles of bound AFB/sub 1/. Moderate decreases of AFB/sub 1/ activation and binding were observed when TPA was present in both cell-free and hepatocytes systems. Only in hepatocytes, BHT inhibited the AFB/sub 1/ uptake and binding to nucleic acids. BHA, however, inhibited microsomal activation of AFB/sub 1/ by 73%; maximum inhibition was reached at 1 mM. AFB/sub 1/ uptake, and binding to nucleic acids were inhibited by 65% and 79% by BHA. GSH-transferase activity of cells treated with these agents was not altered. The effect of BHA at various concentrations on AFB activation was compared with cytochrome P-450 inhibitors; the ED/sub 50/ of SKF 525A, BHA and metyrapone was 9 uM, 80 uM and 380 uM respectively. The data suggest that TPA, BHA and BHT exert their effect by different mechanisms.

  15. Leaching of UO2 pellets doped with alpha-emitters (238/239Pu) in synthetic deep Callovian-Oxfordian groundwater

    Science.gov (United States)

    Tribet, M.; Jégou, C.; Broudic, V.; Marques, C.; Rigaux, P.; Gavazzi, A.

    2010-03-01

    The reactivity of a polycrystalline UO2 surface under alpha irradiation in contact with groundwater is investigated, in the hypothesis of direct disposal of spent fuel in a deep geological repository. Two series of plutonium-doped UO2 samples (specific alpha activity of 18 and 385 MBq·g-1UO2) were leached in a synthetic Callovian-Oxfordian deep groundwater under anoxic conditions (Ar/CO2 3000 ppm, 3.5 bar relative pressure) to assess both the impact of alpha radiolysis of water and the complexing capacity of the groundwater ions on the dissolution of UO2. This study follows a prior one performed in pure and carbonated waters. Firstly, technical developments were necessary for the analyses in the groundwater solution because of its high salt concentrations: quantification limits were determined for the measurement of uranium and radiolytic H2O2 traces in this medium. Secondly, given the very high reactivity of these samples in the presence of air and in order to minimize any prior surface oxidation, a strict experimental protocol was followed, based on high-temperature annealing in Ar + 4% H2 with preleaching cycles. Each type of UO2 pellet was then leached under static conditions for 30 days (anoxic conditions, deep groundwater solutions). Results on the evolution of uranium releases are presented. For the lowest alpha activity (18 MBq·g-1UO2), uranium releases in groundwater were below the quantification limit of 2 × 10-8 mol·L-1 with a kinetic phosphorescence analyzer, even after 30 days. However, for higher alpha activity (385 MBq·g-1UO2) the uranium releases begin to exceed the quantification limit after 14 days of leaching and then increase exponentially. This increase is comparable to results previously obtained in carbonated solutions.

  16. Novel method to assessing and the impact of alpha emitter's concentration of the uterus on women fertility in Iraqi Kurdistan region

    International Nuclear Information System (INIS)

    In the present work, 30 uterine tissue samples were collected from women with uterine problems from Iraqi Kurdistan. Tissue samples were analyzed and examined to measure levels of concentrated α-particle emitters and their short-lived decay products using a plastic track detector (CR-39) and the PVC long-tube technique with standard source radium (226Ra). A new method and apparatus for the passive sampling of α-particles were also introduced. The maximum 0.0691 ppm and minimum 0.0180 ppm concentrations of particles were found in Sedakan and in Dukan, respectively; the average value was 0.0330 ppm, when compared the result with the result (0.12 ppm) in Asumadu-Sakyi et al. (Res J Environ Earth Sci 3(1):24-31, 2011) is lower than it and is agree with the result in Rubyie (Radioactive detection on the blood samples of cancer patients diseases by using CR-39 detector and its effect on cytogenetic. MSc. thesis, Al-Nahrain University, 2007). Also the results of fresh uterus are Significant (p 222Rn gas varied from one woman to another depending on her age, the allergic reaction of her uterus to the radiation, and the geological formation of the area under study. The hazardous effects of α-particles are caused by increasing levels of ionizing radiation in the environment. (author)

  17. MUSE integral-field spectroscopy towards the Frontier Fields cluster Abell S1063: II. Properties of low luminosity Lyman alpha emitters at z>3

    CERN Document Server

    Karman, W; Caminha, G B; Gronke, M; Grillo, C; Balestra, I; Rosati, P; Vanzella, E; Coe, D; Dijkstra, M; Koekemoer, A M; Mercurio, A; Nonino, M

    2016-01-01

    In spite of their conjectured importance for the Epoch of Reionization, the properties of low-mass galaxies are currently still under large debate. In this article, we study the stellar and gaseous properties of faint, low-mass galaxies at z>3. We observed the Frontier Fields cluster Abell S1063 with MUSE over a 2 arcmin^2 field, and combined integral-field spectroscopy with gravitational lensing to perform a blind search for intrinsically faint Lya emitters (LAEs). We found in total 14 lensed LAEs and increased the number of spectroscopically-confirmed multiple-image families from 6 to 17, and updated our gravitational-lensing model accordingly. The lensing-corrected Lya luminosities are with L(Lya) =3 are reported. We performed SED modelling to broadband photometry from the {\\em U}-band through the infrared to determine the stellar properties of these LAEs. The stellar masses are very low (10^{6-8} Msun), and are accompanied by very young ages of 1-100 Myr. The very high specific star formation rates (~100/...

  18. Aberration Corrected Emittance Exchange

    CERN Document Server

    Nanni, Emilio A

    2015-01-01

    Full exploitation of emittance exchange (EEX) requires aberration-free performance of a complex imaging system including active radio-frequency (RF) elements which can add temporal distortions. We investigate the performance of an EEX line where the exchange occurs between two dimensions with normalized emittances which differ by orders of magnitude. The transverse emittance is exchanged into the longitudinal dimension using a double dog-leg emittance exchange setup with a 5 cell RF deflector cavity. Aberration correction is performed on the four most dominant aberrations. These include temporal aberrations that are corrected with higher order magnetic optical elements located where longitudinal and transverse emittance are coupled. We demonstrate aberration-free performance of emittances differing by 4 orders of magnitude, i.e. an initial transverse emittance of $\\epsilon_x=1$ pm-rad is exchanged with a longitudinal emittance of $\\epsilon_z=10$ nm-rad.

  19. A New Population of High-z, Dusty Lyman-alpha Emitters and Blobs Discovered by WISE: Feedback Caught in the Act?

    Science.gov (United States)

    Bridge, Carrie R.; Blain, Andrew; Borys, Colin J. K.; Petty, Sara; Benford, Dominic; Eisenhardt, Peter; Farrah, Duncan; Griffith, Roger, L.; Jarrett, Tom; Lonsdale, Carol; Stanford. Spencer A.; Stern, Daniel; Tsai, Chao-Wei; Wright, Edward L.; Wu, Jingwen

    2013-01-01

    By combining data from the NASA Wide-field Infrared Survey Explorer (WISE) mission with optical spectroscopy from the W. M. Keck telescope, we discover a mid-IR color criterion that yields a 78% success rate in identifying rare, typically radio-quiet, 1.6 approx. 10(exp 13)-10(exp 14) Solar L) and have warm colors. They are typically more luminous and warmer than other dusty, z approx.. 2 populations such as submillimeter-selected galaxies and dust-obscured galaxies. These traits are commonly associated with the dust being illuminated by intense active galactic nucleus activity. We hypothesize that the combination of spatially extended Ly-alpha, large amounts of warm IR-luminous dust, and rarity (implying a short-lived phase) can be explained if the galaxies are undergoing brief, intense "feedback" transforming them from an extreme dusty starburst/QSO into a mature galaxy.

  20. Lung cancer risk of low-level exposures to alpha emitters: critical reappraisal and experiments based on a new cytodynamic model

    Energy Technology Data Exchange (ETDEWEB)

    Bogen, Kenneth T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    1999-02-20

    Ecologic U.S. county data suggest negative associations between residential radon exposure and lung cancer mortality (LCM)-inconsistent with clearly positive associations revealed by occupational data on individual miners, but perhaps explained by competing effects of cell killing vs. mutations in alpha-exposed bronchial epithelium. To assess the latter possibility, a biologically based "cytodynamic 2-stage" (CD2) cancer-risk model was fit to combined 1950-54 age- specific person-year data on lung cancer mortality (LCM) in white females of age 40+ y in 2,821 U.S. counties (-90% never-smokers), and in 5 cohorts of underground miners who never smoked. New estimates of household annual average radon exposure in U.S. counties were used, which were found to have a significant negative ecologic association with 1950-54 LCM in U.S. white females, adjusted for age and all subsets of two among 21 socioeconomic, climatic and other factors considered. A good CD2 fit was obtained to the combined residential/miner data, using biologically plausible parameter values. Without further optimization, the fit also predicted independent inverse dose-rate effects shown (for the first time) to occur in nonsmoking miners. Using the same U.S. county-level LCM data, a separate study revealed a positive ecologic association between LCM and bituminous coal use in the U.S., in agreement with epidemiological data on LCM in women in China. The modeling results obtained are consistent with the CD2-based hypothesis that residential radon exposure has a nonlinear U-shaped relation to LCM risk, and that current linear no-threshold extrapolation models substantially overestimate such risk. A U-shaped dose-response corresponds to a CD2-model prediction that alpha radiation kills more premalignant cells than it generates at low exposure levels, but not at higher levels. To test this hypothesis, groups of Japanese medaka (ricefish minnows) were exposed for 10 to 14 weeks to different concentrations of

  1. Concurrent Supermassive Black Hole and Galazy Growth: Linking Environment and Nuclear Activity in Zeta Equals 2.23 H Alpha Emitters

    Science.gov (United States)

    Lehmer, B. D.; Lucy, A. B.; Alexander, D. M.; Best, P. N.; Geach, J. E.; Harrison, C. M.; Hornschemeier, A. E.; Matsuda, Y.; Mullaney, J. R.; Smail, Ian; Sobral, D.; Swinbank, A. M.

    2013-01-01

    We present results from an approximately equal 100 ks Chandra observation of the 2QZ Cluster 1004+00 structure at z = 2.23 (hereafter 2QZ Clus). 2QZ Clus was originally identified as an overdensity of four optically-selected QSOs at z = 2.23 within a 15 × 15 arcmin square region. Narrow-band imaging in the near-IR (within the K band) revealed that the structure contains an additional overdensity of 22 z = 2.23 H alpha-emitting galaxies (HAEs), resulting in 23 unique z = 2.23 HAEs/QSOs (22 within the Chandra field of view). Our Chandra observations reveal that three HAEs in addition to the four QSOs harbor powerfully accreting supermassive black holes (SMBHs), with 2-10 keV luminosities of approximately equal (8-60) × 10(exp 43) erg s(exp-1) and X-ray spectral slopes consistent with unobscured active galactic nucleus (AGN). Using a large comparison sample of 210 z = 2.23 HAEs in the Chandra-COSMOS field (C-COSMOS), we find suggestive evidence that the AGN fraction increases with local HAE galaxy density. The 2QZ Clus HAEs reside in a moderately overdense environment (a factor of approximately equal 2 times over the field), and after excluding optically-selected QSOs, we find that the AGN fraction is a factor of approximately equal 3.5(+3.8/ -2.2) times higher than C-COSMOS HAEs in similar environments. Using stacking analyses of the Chandra data and Herschel SPIRE observations at 250micrometers, we respectively estimate mean SMBH accretion rates ( M(BH)) and star formation rates (SFRs) for the 2QZ Clus and C-COSMOS samples. We find that the mean 2QZ Clus HAE stacked X-ray luminosity is QSO-like (L(2-10 keV) approximately equal [6-10] × 10(exp 43) erg s(exp -1)), and the implied M(BH)/SFR approximately equal (1.6-3.2) × 10(exp -3) is broadly consistent with the local M(BH)/Stellar Mass relation and z approximately equal 2 X-ray selected AGN. In contrast, the C-COSMOS HAEs are on average an order of magnitude less X-ray luminous and have M(BH)/SFR approximately

  2. A Randomized Multicentre Phase II Trial Comparing Adjuvant Therapy in Patients with Interferon Alpha-2b and 5-FU Alone or in Combination with Either External Radiation Treatment and Cisplatin (CapRI) or Radiation alone regarding Event-Free Survival – CapRI-2

    International Nuclear Information System (INIS)

    The 5-year survival of patients with resected pancreatic adenocarcinoma is still unsatisfying. The ESPAC-1 and the CONKO 001 trial proofed that adjuvant chemotherapy improves 5-year survival significantly from approximately 14% to 21%. In parallel, investigators from the Virginia Mason Clinic reported a 5-year survival rate of 55% in a phase II trial evaluating a combination of adjuvant chemotherapy, immunotherapy and external beam radiation (CapRI-scheme). Two other groups confirmed in phase II trials these results to a certain extent. However, these groups reported severe gastrointestinal toxicity (up to 93% grade 3 or 4 toxicity). In a randomized controlled phase III trial, called CapRI, 110 patients were enrolled from 2004 to 2007 in Germany and Italy to check for reproducibility. Interestingly, much less gastrointestinal toxicity was observed. However, dose-reduction due to haematological side effects had to be performed in nearly all patients. First clinical results are expected for the end of 2009. CapRI-2 is an open, controlled, prospective, randomized, multicentre phase II trial with three parallel arms. A de-escalation of the CapRI-scheme will be tested in two different modifications. Patients in study arm A will be treated as outpatients with the complete CapRI-scheme consisting of cisplatin, Interferon alpha-2b and external beam radiation and three cycles of 5-fluorouracil continuous infusion. In study arm B the first de-escalation will be realised by omitting cisplatin. Next, patients in study arm C will additionally not receive external beam radiation. A total of 135 patients with pathologically confirmed R0 or R1 resected pancreatic adenocarcinoma are planned to be enrolled. Primary endpoint is the comparison of the treatment groups with respect to six-month event-free-survival. An event is defined as grade 3 or grade 4 toxicity, objective tumour recurrence, or death. The aim of this clinical trial is to evaluate de-escalation of the CapRI-scheme. It

  3. Measurements of {beta} or {alpha} emitter long lived radionuclides using inductively coupled plasma mass spectrometry; Dosage a tres bas niveau de radionucleides a longue periode emetteurs {beta} ou {alpha} par spectrometrie de masse a couplage plasma inductif

    Energy Technology Data Exchange (ETDEWEB)

    Provitina, O.

    1993-10-18

    The measurement of long-lived radionuclides is highly important for characterizing nuclear wastes for their later storage. The main techniques are {alpha} spectrometry, {beta} counting and {gamma} spectrometry. The large period of these isotopes leads to low specific activity needing time consuming measurements. Moreover, the radiometric techniques are often limited by problems of interferences involving several steps of pretreatments. Among these steps, the specific extraction with crown ethers is highly selective for the separation of {sup 99}Tc, {sup 129}I and {sup 135}Cs. The radiometric techniques are here replaced by inductively coupled plasma mass spectroscopy (ICP-MS) the advantages of which are: few interferences, sensitivity which does not depend on the radiologic period as compared to radiochemistry. ICP-MS can then measure {sup 237}Np in enriched uranium matrix and reduce by a factor of 4 the sample pretreatment and the duration of the analysis usually performed by {alpha} spectrometry. Another technique, electrothermal vaporization (ETV), is consequently used. Crown ether extraction-ETV-ICP-MS is employed for measuring the long lived radionuclides {sup 99}Tc and {sup 129}I. The conditions of the extraction and the parameters of the ETV and the ICP-MS are studied and optimized. The methods optimized (extraction, electrothermal vaporization) are validated in the case of {sup 99}Tc, in real samples. The spike method is required to quantify technetium, the quantification with calibration leading to bad results. The results obtained are in good agreement with the expected values. Extraction of technetium on anionic resin and its measurement by the spike method with pneumatic nebulization-ICP-MS is also performed on other samples. Measured values are also in agreement with expected values, but the method of extraction is more time consuming (half a day) than the extraction with crown ether (one hour). (author). 54 figs., 38 tabs.

  4. Evaluations of carbon nanotube field emitters for electron microscopy

    International Nuclear Information System (INIS)

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I-V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6x109 A/m2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  5. Cytochrome P450c17 (steroid 17. cap alpha. -hydroxylase/17,20 lyase): cloning of human adrenal and testis cDNAs indicates the same gene is expressed in both tissues

    Energy Technology Data Exchange (ETDEWEB)

    Chung, B.; Picado-Leonard, J.; Haniu, M.; Bienkowski, M.; Hall, P.F.; Shively, J.E.; Miller, W.L.

    1987-01-01

    P450c17 is the single enzyme mediating both 17..cap alpha..-hydroxylase (steroid 17..cap alpha..-monooxygenase, EC 1.14.99.9) and 17,20 lyase activities in the synthesis of steroid hormones. It has been suggested that different P450c17 isozymes mediate these activities in the adrenal gland and testis. The authors sequenced 423 of the 509 amino acids (83%) of the porcine adrenal enzyme; based on this partial sequence, a 128-fold degenerate 17-mer was synthesized and used to screen a porcine adrenal cDNA library. This yielded a 380-base cloned cDNA, which in turn was used to isolate several human adrenal cDNAs. The longest of these, lambda hac 17-2, is 1754 base pairs long and includes the full-length coding region, the complete 3'-untranslated region, and 41 bases of the 5'-untranslated region. This cDNA encodes a protein of 508 amino acids having a predicted molecular weight of 57,379.82. High-stringency screening of a human testicular cDNA library yielded a partial clone containing 1303 identical bases. RNA gel blots and nuclease S1-protection experiments confirm that the adrenal and testicular P450c17 mRNAs are indistinguishable. These data indicate that the testis possesses a P450c17 identical to that in the adrenal. The human amino acid sequence is 66.7% homologous to the corresponding regions of the porcine sequence, and the human cDNA and amino acid sequences are 80.1 and 70.3% homologous, respectively, to bovine adrenal P450c17 cDNA. Both comparisons indicate that a central region comprising amino acid residues 160-268 is hypervariable among these species of P450c17.

  6. Comparison of U.S. Environmental Protection Agency's CAP88 PC Versions 3.0 and 4.0.

    Science.gov (United States)

    Jannik, Tim; Farfan, Eduardo B; Dixon, Ken; Newton, Joseph; Sailors, Christopher; Johnson, Levi; Moore, Kelsey; Stahman, Richard

    2015-08-01

    The Savannah River National Laboratory (SRNL) with the assistance of Georgia Regents University, completed a comparison of the U.S. Environmental Protection Agency's (U.S. EPA) environmental dosimetry code CAP88 PC V3.0 with the recently developed V4.0. CAP88 is a set of computer programs and databases used for estimation of dose and risk from radionuclide emissions to air. At the U.S. Department of Energy's Savannah River Site, CAP88 is used by SRNL for determining compliance with U.S. EPA's National Emission Standards for Hazardous Air Pollutants (40 CFR 61, Subpart H) regulations. Using standardized input parameters, individual runs were conducted for each radionuclide within its corresponding database. Some radioactive decay constants, human usage parameters, and dose coefficients changed between the two versions, directly causing a proportional change in the total effective dose. A detailed summary for select radionuclides of concern at the Savannah River Site (60Co, 137Cs, 3H, 129I, 239Pu, and 90Sr) is provided. In general, the total effective doses will decrease for alpha/beta emitters because of reduced inhalation and ingestion rates in V4.0. However, for gamma emitters, such as 60Co and 137Cs, the total effective doses will increase because of changes U.S. EPA made in the external ground shine calculations.

  7. Phase III trial of postoperative cisplatin, interferon alpha-2b, and 5-FU combined with external radiation treatment versus 5-FU alone for patients with resected pancreatic adenocarcinoma – CapRI: study protocol [ISRCTN62866759

    Directory of Open Access Journals (Sweden)

    Schmitz-Winnenthal H

    2005-04-01

    Full Text Available Abstract After surgical intervention with curative intention in specialised centres the five-year survival of patients with carcinoma of the exocrine pancreas is only 15%. The ESPAC-1 trial showed an increased five-year survival of 21% achieved with adjuvant chemotherapy. Investigators from the Virginia Mason Clinic have reported a 5-year survival rate of 55% in a phase II trial evaluating adjuvant chemotherapy, immunotherapy and external-beam radiation. Design The CapRI study is an open, controlled, prospective, randomised multi-centre phase III trial. Patients in study arm A will be treated as outpatients with 5-Fluorouracil; Cisplatin and 3 million units Interferon alpha-2b for 5 1/2 weeks combined with external beam radiation. After chemo-radiation the patients receive continuous 5-FU infusions for two more cycles. Patients in study arm B will be treated as outpatients with intravenous bolus injections of folinic acid, followed by intravenous bolus injections of 5-FU given on 5 consecutive days every 28 days for 6 cycles. A total of 110 patients with specimen-proven R0 or R1 resected pancreatic adenocarcinoma will be enrolled. An interim analysis for patient safety reasons will be done one year after start of recruitment. Evaluation of the primary endpoint will be performed two years after the last patients' enrolment. Discussion The aim of this study is to evaluate the overall survival period attained by chemo-radiotherapy including interferon alpha 2b administration with adjuvant chemotherapy. The influence of interferon alpha on the effectiveness of the patients' chemoradiation regimen, the toxicity, the disease-free interval and the quality of life are analysed. Different factors are tested in terms of their potential role as predictive markers.

  8. The DIORAMA Neutron Emitter

    Energy Technology Data Exchange (ETDEWEB)

    Terry, James Russell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-05

    Emission of neutrons in a given event is modeled by the DioramaEmitterNeutron object, a subclass of the abstract DioramaEmitterModule object. The GenerateEmission method of this object is the entry point for generation of a neutron population for a given event. Shown in table 1, this method requires a number of parameters to be defined in the event definition.

  9. Beta emitters and radiation protection

    DEFF Research Database (Denmark)

    Jødal, Lars

    2009-01-01

    BACKGROUND. Beta emitters, such as 90Y, are increasingly being used for cancer treatment. However, beta emitters demand other precautions than gamma emitters during preparation and administration, especially concerning shielding. AIM. To discuss practical precautions for handling beta emitters...... on the outside of the primary shielding material. If suitable shielding is used and larger numbers of handlings are divided among several persons, then handling of beta emitters can be a safe procedure....

  10. Death cap

    DEFF Research Database (Denmark)

    Rudbæk, Torsten R; Kofoed, Pernille Bouteloup; Bove, Jeppe;

    2014-01-01

    Death cap (Amanita phalloides) is commonly found and is one of the five most toxic fungi in Denmark. Toxicity is due to amatoxin, and poisoning is a serious medical condition, causing organ failure with potential fatal outcome. Acknowledgement and clarification of exposure, symptomatic and focused...... treatment is of primary importance. No data from randomised, controlled trials on management exists, and there is not international consensus on treatment regime. We present amatoxin-case contacts to the Danish Poison Centre from 2006-2012 and summarize current knowledge and Danish recommendations...

  11. Cancer from internal emitters

    International Nuclear Information System (INIS)

    Irradiation from internal emitters, or internally deposited radionuclides, is an important component of radiation exposures encountered in the workplace, home, or general environment. Long-term studies of human populations exposed to various internal emitters by different routes of exposure are producing critical information for the protection of workers and members of the general public. The purpose of this report is to examine recent developments and discuss their potential importance for understanding lifetime cancer risks from internal emitters. The major populations of persons being studied for lifetime health effects from internally deposited radionuclides are well known: Lung cancer in underground miners who inhaled Rn progeny, liver cancer from persons injected with the Th-containing radiographic contrast medium Thorotrast, bone cancer from occupational or medical intakes of 226Ra or medical injections of 224Ra, and thyroid cancer from exposures to iodine radionuclides in the environment or for medical purposes

  12. PENCIL LEAD FIELD EMITTER

    OpenAIRE

    Khairnar, R.; Joag, D.

    1989-01-01

    Field electron emission from 2H and HB grades of pencil lead has been studied. The pencil lead field emitter is found to obey the Fowler-Nordheim characteristics. The emission current fluctuations are found to increase with the residual gas pressure and the emission current. The current density of the order of 106 amp/cm2 could be drawn from these emitters. The emission stability over the operation of six hours has been found to be reasonably good. The field ion microscopy of the 2H and HB gr...

  13. RFI emitter location techniques

    Science.gov (United States)

    Rao, B. L. J.

    1973-01-01

    The possibility is discussed of using Doppler techniques for determining the location of ground based emitters causing radio frequency interference with low orbiting satellites. An error analysis indicates that it is possible to find the emitter location within an error range of 2 n.mi. The parameters which determine the required satellite receiver characteristic are discussed briefly along with the non-real time signal processing which may by used in obtaining the Doppler curve. Finally, the required characteristics of the satellite antenna are analyzed.

  14. Reactor neutron activation analysis for aluminium in the presence of phosphorus and silicon. Contributions of /sup 28/Al activities from /sup 31/P (n,. cap alpha. ) /sup 28/Al and /sup 28/Si (n,p) /sup 28/Al reactions

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, Yoshihiko (Kinki Univ., Higashi-Osaka, Osaka (Japan). Faculty of Science and Technology); Iwata, Shiro; Sasajima, Kazuhisa; Yoshimasu, Fumio; Yase, Yoshiro

    1984-01-01

    Reactor neutron activation analysis for aluminium in samples containing phosphorus and silicon was studied. The experiments were performed by using pneumatic tube of the Kyoto University Reactor (KUR). At first, the ratios of the /sup 28/Al activity produced from /sup 27/Al(n, ..gamma..) /sup 28/Al reaction by thermal neutrons to that from /sup 31/P(n, ..cap alpha..)/sup 28/Al reaction by fast neutrons, and to that from /sup 28/Si(n, p)/sup 28/Al reaction were measured by ..gamma..-ray spectrometry. With a ratio of about 5 for the thermal to fast neutron flux of KUR, the ratio of the /sup 28/Al activity from aluminium to that from phosphorus was to be 812 +- 7, and to that from silicon 282 +- 3. Secondly, the contributions of /sup 28/Al activities from phosphorus and silicon and the determination limit of aluminium were calculated for various parameters, such as fast neutron flux, thermal to fast neutron flux ratio, amounts of phosphorus and silicon, etc. Thirdly, on the basis of these results, aluminium contents in spinal cords and brains of amyotrophic lateral sclerosis, Parkinsonism-dementia complex and control cases were determined.

  15. Synthesis and Photoelectrical Properties of Two Potential Solution-Processed Blue Fluorescent Emitters Based on Fluorene-Arylamine Derivatives End-Capped with Anthracene/Pyrene Molecules%基于蒽/芘分子封端的芴-芳胺衍生物的可溶液加工的蓝光材料的合成与光电性质

    Institute of Scientific and Technical Information of China (English)

    欧阳密; 吴启超; 余振伟; 李洪飞; 张诚

    2014-01-01

    Two novel potential solution-processed blue fluorescent emitters composed of a core fluorene-diphenylamine unit capped with either anthracene (FAn) or pyrene (FPy) were synthesized and characterized. They were both soluble in common organic solvents and solutions gave smooth films after spin coating. Their optical properties in solution and in the film were investigated by UV-visible and photoluminescence (PL) spectroscopy. The PL emission maximum of FAn and FPy in the film state were found to be 449 and 465 nm, respectively. The electrochemical properties of the as-prepared samples were studied by cyclic voltammetry. The estimated highest occupied molecular orbital (HOMO) energy levels were-5.37 and-5.36 eV for FAn and FPy, respectively. These results indicate that the introduction of diphenylamine effectively prevents plane stacking of the molecules in the solid state, which suppresses the formation of long-wavelength aggregates, and the high HOMO levels enhance the hole-injection ability of the compounds. The results of differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) indicate that the two materials have excellent thermal stability with the glass transition temperature of FAn reaching 207 °C and the thermal decomposition temperature as high as 439 ° C. The good performance of the fluorescent emitters makes them promising candidates as solution-processed blue organic light-emitting diodes.%合成了两类分别基于芘和蒽封端的芴-芳胺衍生物(FAn, FPy)的新型可溶液加工蓝色发光分子,两种材料均溶于常规的有机溶剂,并且可以旋涂成膜.通过紫外-可见光谱和荧光光谱对其在溶液中和固态薄膜下的光学性能进行了表征,发现这两类分子在固态下发射峰分别位于449和465 nm,属于蓝色发光材料.并通过循环伏安法表征了其电化学性能,计算得出FAn和FPy的最高占据分子轨道(HOMO)能级分别为-5.37和-5.36 eV.结果表明N-己基二苯胺

  16. Alpha voltaic batteries and methods thereof

    Science.gov (United States)

    Raffaelle, Ryne P. (Inventor); Jenkins, Phillip (Inventor); Wilt, David (Inventor); Scheiman, David (Inventor); Chubb, Donald (Inventor); Castro, Stephanie (Inventor)

    2011-01-01

    An alpha voltaic battery includes at least one layer of a semiconductor material comprising at least one p/n junction, at least one absorption and conversion layer on the at least one layer of semiconductor layer, and at least one alpha particle emitter. The absorption and conversion layer prevents at least a portion of alpha particles from the alpha particle emitter from damaging the p/n junction in the layer of semiconductor material. The absorption and conversion layer also converts at least a portion of energy from the alpha particles into electron-hole pairs for collection by the one p/n junction in the layer of semiconductor material.

  17. Low-emittance Storage Rings

    CERN Document Server

    Wolski, A

    2014-01-01

    The effects of synchrotron radiation on particle motion in storage rings are discussed. In the absence of radiation, particle motion is symplectic, and the beam emittances are conserved. The inclusion of radiation effects in a classical approximation leads to emittance damping: expressions for the damping times are derived. Then, it is shown that quantum radiation effects lead to excitation of the beam emittances. General expressions for the equilibrium longitudinal and horizontal (natural) emittances are derived. The impact of lattice design on the natural emittance is discussed, with particular attention to the special cases of FODO-, achromat- and theoretical-minimum-emittance-style lattices. Finally, the effects of betatron coupling and vertical dispersion (generated by magnet alignment and lattice tuning errors) on the vertical emittance are considered.

  18. Directional Thermal Emitter Simulation

    OpenAIRE

    Dhaka, Shailja; Sakr, Enas Said; Bermel, Peter

    2015-01-01

    The development of renewable energy sources has attracted increasing interest because of negative externalities associated with fossil fuel use. Thermophotovoltaics is a promising technology, in which a thermal emitter radiates photons which are directly converted into electricity using a photovoltaic diode. However, blackbody emission includes a broad range of wavelengths, but only higher energy photons can be converted into electricity. Thus, tailoring the selectivity of thermal emission is...

  19. Synthesis of tritiated 1-alpha-methadol and 1-alpha-acetylmethadol

    Energy Technology Data Exchange (ETDEWEB)

    Thang, D.C.; Nam, N.H.; Pontikis, R. (Institut National de la Sante et de la Recherche Medicale (INSERM), Hopital Fernand Widal, 75 - Paris (France)); Pichat, L. (CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service des Molecules Marquees)

    1982-04-01

    dl-Methadone was resolved by crystallization of its ammonium d- ..cap alpha.. -bromocamphor-..pi..-sulfonate salt to give d-methadone. The latter in ethyl acetate solution was reduced with tritium gas to 1-..cap alpha..-methadol /sup 3/H in presence of Adams platinum oxide at normal temperature and pressure. Acetylation of 1-..cap alpha..-carbinol hydrochloride by means of acetyl chloride afforded 1-..cap alpha..-acetylmethadol /sup 3/H, specific activity: 20 Ci/mMole. The positions and extent of tritium labelling were determined by /sup 3/H NMR spectroscopy.

  20. Measurement of emittance and emittance reduction in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Palladino, Vittorio [Univ. and Istituto Nazionale di Fisica Nucleare - INFN, Sezione di Napoli, Complesso Universitario di Monte Sant' Angelo, via Cintia, I-80126, Napoli (Italy); Verguilov, Vassil [Departement de physique nucleaire et corpusculaire - DPNC, Geneva University, 24, Quai Ernest Ansermet, 1211 Geneve 4 (Switzerland)

    2010-07-01

    MICE is building at RAL a muon beam with tunable emittance and an array of detectors capable to measure the emittance of the beam before and after any ionization cooling device that will be designed in the future. This talk will present the details of the measurements of beam emittance and of emittance reduction, the tracking and particle identification instrumentation used for this purpose, the physical observables and the techniques being prepared to provide convincing evidence of effective ionisation cooling. After the measurement of the transverse cooling performances of the cooling cell designed in early feasibility studies of a neutrino factory, the MICE beam and emittance measurement devices will remain as a facility for the study of new candidate cooling cell prototypes, including exchange between transverse and longitudinal emittance cooling. Some of those emerging options will also be briefly mentioned. (author)

  1. Helium precipitation in. cap alpha. -Fe

    Energy Technology Data Exchange (ETDEWEB)

    Caspers, L.M.; van Veen, A.; Ypma, M.R.; van der Kolk, G.J. (Interuniversitair Reactor Inst., Delft (Netherlands))

    1982-03-16

    The filling of a vacancy with helium atoms is studied with a programme simulating the relaxation of lattice atoms around the complex. Three filling modes are described. Helium filled V/sub 2/, V/sub 3/, and V/sub 4/ complexes are also considered and the energetics of the mutation reactions of He/sub n/V ..-->.. He/sub m>n/V/sub 2/ ..-->.. He/sub p>m/V/sub 3/ ..-->.. He/sub q>p/V/sub 4/ is studied. It is shown that these mutation reactions are more probable when the emitted interstitials remain bound to the mutation products. The He/sub n/V/sub m/I/sub p/ complexes thus formed are stable against reduction, in agreement with experiments. Also the formation of these complexes could explain why helium precipitation proceeds in a two-dimensional way as observed by TEM. The general trend found in helium desorption measurements viz. a decrease in helium binding energy until some 6 to 10 He atoms are trapped and thereafter an increase in binding energy is also found in this computer simulation study.

  2. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing; Yang, Peidong; Kim, Woong; Fan, Rong

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  3. Emittance growth in rf linacs

    International Nuclear Information System (INIS)

    As the space-charge limit is approached, the current that can be accelerated in an rf linac and the output emittance that can be expected are discussed. The role of the envelope equations to estimate limits is outlined. The results of numerical experiments to explore general properties of emittance growth are given

  4. Beam emittance measurements in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Zelenski,A.; Bazilevsky, A.; Bunce, G.; Gill, R.; Huang, H.; Makdisi, Y.; Morozov, B.; Nemesure, S.; Russo, t.; Steski, D.; Sivertz, M.

    2009-05-04

    The RHIC proton polarimeters can operate in scanning mode, giving polarization profiles and transverse beam intensity profile (beam emittance) measurements. The polarimeters function as wire scanners, providing a very good signal/noise ratio and high counting rate. This allows accurate bunch-by-bunch emittance measurements during fast target sweeps (<1 s) through the beam. Very thin carbon strip targets make these measurements practically non-destructive. Bunch by bunch emittance measurements are a powerful tool for machine set-up; in RHIC, individual proton beam transverse emittances can only be measured by CNI polarimeter scans. We discuss the consistency of these measurements with Ionization Profile Monitors (IPMs) and vernier scan luminosity measurements. Absolute accuracy limitations and cross-calibration of different techniques are also discussed.

  5. Diamondoid monolayers as electron emitters

    Science.gov (United States)

    Yang, Wanli; Fabbri, Jason D.; Melosh, Nicholas A.; Hussain, Zahid; Shen, Zhi-Xun

    2012-04-10

    Provided are electron emitters based upon diamondoid monolayers, preferably self-assembled higher diamondoid monolayers. High intensity electron emission has been demonstrated employing such diamondoid monolayers, particularly when the monolayers are comprised of higher diamondoids. The application of such diamondoid monolayers can alter the band structure of substrates, as well as emit monochromatic electrons, and the high intensity electron emissions can also greatly improve the efficiency of field-effect electron emitters as applied to industrial and commercial applications.

  6. Visible Spectrum Incandescent Selective Emitter

    Energy Technology Data Exchange (ETDEWEB)

    Sonsight Inc.

    2004-04-30

    The purpose of the work performed was to demonstrate the feasibility of a novel bi-layer selective emitter. Selective emitters are incandescent radiant bodies with emissivities that are substantially larger in a selected part of the radiation spectrum, thereby significantly shifting their radiated spectral distribution from that of a blackbody radiating at the same temperature. The major research objectives involved answering the following questions: (1) What maximum VIS/NIR radiant power and emissivity ratios can be attained at 2650 K? (2) What is the observed emitter body life and how does its performance vary with time? (3) What are the design tradeoffs for a dual heating approach in which both an internally mounted heating coil and electrical resistance self-heating are used? (4) What are the quantitative improvements to be had from utilizing a bi-layer emitter body with a low emissivity inner layer and a partially transmissive outer layer? Two approaches to obtaining selective emissivity were investigated. The first was to utilize large optical scattering within an emitter material with a spectral optical absorption that is much greater within the visible spectrum than that within the NIR. With this approach, an optically thick emitter can radiate almost as if optically thin because essentially, scattering limits the distance below the surface from which significant amounts of internally generated radiation can emerge. The performance of thin emitters was also investigated (for optically thin emitters, spectral emissivity is proportional to spectral absorptivity). These emitters were fabricated from thin mono-layer emitter rods as well as from bi-layer rods with a thin emitter layer mounted on a substrate core. With an initially estimated energy efficiency of almost three times that of standard incandescent bulbs, a number of energy, economic and environmental benefits such as less energy use and cost, reduced CO{sub 2} emissions, and no mercury contamination

  7. Sets of Reports and Articles Regarding Cement Wastes Forms Containing Alpha Emitters that are Potentially Useful for Development of Russian Federation Waste Treatment Processes for Solidification of Weapons Plutonium MOX Fuel Fabrication Wastes for

    Energy Technology Data Exchange (ETDEWEB)

    Jardine, L J

    2003-06-12

    This is a set of nine reports and articles that were kindly provided by Dr. Christine A. Langton from the Savannah River Site (SRS) to L. J. Jardine LLNL in June 2003. The reports discuss cement waste forms and primarily focus on gas generation in cement waste forms from alpha particle decays. However other items such as various cement compositions, cement product performance test results and some cement process parameters are also included. This set of documents was put into this Lawrence Livermore National Laboratory (LLNL) releasable report for the sole purpose to provide a set of documents to Russian technical experts now beginning to study cement waste treatment processes for wastes from an excess weapons plutonium MOX fuel fabrication facility. The intent is to provide these reports for use at a US RF Experts Technical Meeting on: the Management of Wastes from MOX Fuel Fabrication Facilities, in Moscow July 9-11, 2003. The Russian experts should find these reports to be very useful for their technical and economic feasibility studies and the supporting R&D activities required to develop acceptable waste treatment processes for use in Russia as part of the ongoing Joint US RF Plutonium Disposition Activities.

  8. Emittance measurements on ETA and ATA

    International Nuclear Information System (INIS)

    Emittance measurements on beams produced by the ETA and ATA accelerators are discussed. Emittance and brightness are defined. The significance of emittance for a beam in an accelerator and in gas is discussed. Various measurement techniques and results are presented and contrasted. Implicit calculations of emittance are also reported. Finally, the measurement of the time variation of emittance is discussed and the techniques to be used on the upcoming ATA experiments are outlined

  9. Microtubule's conformational cap

    DEFF Research Database (Denmark)

    Chretien, D.; Janosi, I.; Taveau, J.C.;

    1999-01-01

    The molecular mechanisms that allow elongation of the unstable microtubule lattice remain unclear. It is usually thought that the GDP-liganded tubulin lattice is capped by a small layer of GTP- or GDP-P(i)-liganded molecules, the so called "GTP-cap". Here, we point-out that the elastic properties...

  10. Qualitative and quantitative analysis of beta emitters in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, Zaini bin

    1983-01-01

    A beta spectrometer, consisting of a liquid scintillation counter, coupled to a programmable multichannel analyser was used to achieve the objective of detecting and measuring beta activity in low level aqueous environmental solution as well as identifying the radioisotopes present. Aqueous solutions of standard beta emitters, covering a range of energies between 18.6 KeV and 3550 KeV, were used to develop computer methods for analysis. The effects of pH, acids, bases, buffers, and salts on the stability of the mixture and on the detection efficiency of the radioisotopes, were investigated. It was found that temperature changes, beyond the operating temperature range, could result in severe errors. Application of the Cherenkov counting technique for beta emitters, gives extra data to support the main results. For the analysis of environmental solutions, which may contain a variety of radioisotopes, the system was used to obtain spectra of alpha emitters, beta emitters with internal conversion and Cherenkov radiation. Synthetic mixtures of tritium and carbon-14 of activity ratios between 8:1 and 1:8 were used to investigate the problems of multielement spectral analysis.

  11. Combustion powered thermophotovoltaic emitter system

    Energy Technology Data Exchange (ETDEWEB)

    McHenry, R.S. [Naval Academy, Annapolis, MD (United States). Naval Architecture, Ocean and Marine Engineering

    1995-07-01

    The US Naval Academy (USNA) has recently completed an engineering design project for a high temperature thermophotovoltaic (TPV) photon emitter. The final apparatus was to be portable, completely self contained, and was to incorporate cycle efficiency optimization such as exhaust stream recuperation. Through computer modeling and prototype experimentation, a methane fueled emitter system was designed from structural ceramic materials to fulfill the high temperature requirements necessary for high system efficiency. This paper outlines the engineering design process, discusses obstacles and solutions encountered, and presents the final design.

  12. Green Pea Galaxies Reveal Secrets of Ly$\\alpha$ Escape

    CERN Document Server

    Yang, Huan; Gronke, Max; Rhoads, James E; Jaskot, Anne; Zheng, Zhenya; Dijkstra, Mark

    2015-01-01

    Star-formation in galaxies generates a lot of Ly$\\alpha$ photons. Understanding the escape of Ly$\\alpha$ photons from galaxies is a key issue in studying high redshift galaxies and probing cosmic reionization with Ly$\\alpha$. To understand Ly$\\alpha$ escape, it is valuable to study analogs of high redshift Ly$\\alpha$ emitters in nearby universe. However, most nearby analogs have too small a Ly$\\alpha$ equivalent width and escape fraction compared to high redshift Ly$\\alpha$ emitters. One different group of nearby analogs are "Green Pea" galaxies, selected by their high equivalent width optical emission lines. Here we show that Green Pea galaxies have strong Ly$\\alpha$ emission lines and high Ly$\\alpha$ escape fraction (see also Henry et al. 2015), providing an opportunity to solve Ly$\\alpha$ escape problem. Green Peas have a Ly$\\alpha$ equivalent width distribution similar to high redshift Ly$\\alpha$ emitters. The Ly$\\alpha$ escape fraction correlates with many quantities of Ly$\\alpha$ profile, especially the...

  13. Direct correlation between a negative autoregulatory response element at the cap site of the herpes simplex virus type 1 IE175 (alpha 4) promoter and a specific binding site for the IE175 (ICP4) protein.

    OpenAIRE

    Roberts, M S; Boundy, A; O'Hare, P; Pizzorno, M C; Ciufo, D M; Hayward, G S

    1988-01-01

    In transient-expression assays, the IE175 (alpha 4) promoter region of herpes simple virus is down-regulated after cotransfection with DNA encoding its own protein product (IE175 or ICP4). The inhibition by IE175 proved to be highly specific for its own promoter region and did not act on either the herpes simplex virus type 1 IE110 (alpha 0) or human cytomegalovirus major immediate-early promoters. Furthermore, the inhibition was still exhibited by IE175 effector plasmids driven by strong het...

  14. Intraperitoneal alpha-radioimmunotherapy in mice using different specific activities

    DEFF Research Database (Denmark)

    Elgqvist, Jörgen; Andersson, Håkan; Haglund, Elin;

    2009-01-01

    The aim of this study was to investigate the therapeutic efficacy of the alpha-radioimmunotherapy of ovarian cancer in mice, using different specific activities. This study was performed by using the monoclonal antibody, MX35 F(ab')(2), labeled with the alpha-particle-emitter, 211At.......The aim of this study was to investigate the therapeutic efficacy of the alpha-radioimmunotherapy of ovarian cancer in mice, using different specific activities. This study was performed by using the monoclonal antibody, MX35 F(ab')(2), labeled with the alpha-particle-emitter, 211At....

  15. Ultra Low Emittance Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Bengtsson,J.

    2008-06-23

    This paper outlines the special issues for reaching sub-nm emittance in a storage ring. Effects of damping wigglers, intra-beam scattering and lifetime issues, dynamic aperture optimization, control of optics, and their interrelations are covered in some detail. The unique choices for the NSLS-II are given as one example.

  16. Radiation dosimetry in radiotherapy with internal emitters

    Energy Technology Data Exchange (ETDEWEB)

    Stabin, Michael G. [Oak Ridge Inst. for Science and Education, TN (United States)

    1997-12-31

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  17. Oxidation and emittance of superalloys in heat shield applications

    Science.gov (United States)

    Wiedemann, K. E.; Clark, R. K.; Unnam, J.

    1986-01-01

    Recently developed superalloys that form alumina coatings have a high potential for heat shield applications for advanced aerospace vehicles at temperatures above 1095C. Both INCOLOY alloy MA 956 (of the Inco Alloys International, Inc.), an iron-base oxide-dispersion-strengthened alloy, and CABOT alloy No. 214 (of the Cabot Corporation), an alumina-forming nickel-chromium alloy, have good oxidation resistance and good elevated temperature strength. The oxidation resistance of both alloys has been attributed to the formation of a thin alumina layer (alpha-Al2O3) at the surface. Emittance and oxidation data were obtained for simulated Space Shuttle reentry conditions using a hypersonic arc-heated wind tunnel. The surface oxides and substrate alloys were characterized using X-ray diffraction and scanning and transmission electron microscopy with an energy-dispersive X-ray analysis unit. The mass loss and emittance characteristics of the two alloys are discussed.

  18. Alpha Schottky junction energy source

    Science.gov (United States)

    Litz, Marc S.; Fan, Zhaoyang; Carroll, James J.; Bayne, Stephen

    2012-06-01

    Isotope batteries offer solutions for long-lived low-power sensor requirements. Alpha emitting isotopes have energy per decay 103 times that of beta emitters. Alpha particles are absorbed within 20 μm of most materials reducing shielding mitigation. However, damage to materials from the alphas limits their practical use. A Schottky Barrier Diode (SBD) geometry is considered with an alpha emitting contact-layer on a diamond-like crystal semiconductor region. The radiation tolerance of diamond, the safety of alpha particles, combined with the internal field of the SBD is expected to generate current useful for low-power electronic devices over decades. Device design parameters and calculations of the expected current are described.

  19. Properties of Lya Emitters Around the Radio Galaxy MRC 0316-257

    Energy Technology Data Exchange (ETDEWEB)

    Venemans, B; Rottgering, H; Miley, G; Kurk, J; De Breuck, C; van Breugel, W; Carilli, C; Ford, H; Heckman, T; Pentericci, L; McCarthy, P

    2004-08-12

    Observations of the radio galaxy MRC 0316-257 at z = 3.13 and the surrounding field are presented. Using narrow- and broad-band imaging obtained with the VLT*, 92 candidate Ly{alpha} emitters with a rest-frame equivalent width of > 15 AngstromS were selected in a {approx} 7{prime} x 7{prime} field around the radio galaxy. Spectroscopy of 40 candidate emitters resulted in the discovery of 33 emission line galaxies of which 31 are Ly{alpha} emitters with redshifts similar to that of the radio galaxy, while the remaining two galaxies turned out to be [{omicron} II] emitters. The Ly{alpha} profiles had widths (FWHM) corresponding to 120-800 kms{sup -1},with a median of 260 kms{sup -1}. Where the signal-to-noise spectra was large enough, the Ly{alpha} profiles are found to be asymmetric, with apparent absorption troughs blueward of the profile peaks, indicative of absorption along the line of sight of an {Eta}{Iota} mass of 1-5000 {mu}{circle_dot}. Besides that of the radio galaxy and one of the emitters that is an QSO, the continuum of the emitters is faint, with luminosities ranging from 1.3 L{sub *} to < 0.03 L{sub *}.The colors of the confirmed emitters are, on average, very blue. The median UV continuum slope is {beta}=-1.65, bluer than the average slope of LBGs with Ly{alpha} emitters is 2.6 {Mu}{circle_dot}{sup -1} as measured by the Ly{alpha} emission line or < 3.9 {Mu}{circle_dot}{sup -1} as measured by the UV continuum. The properties of the Ly{alpha} galaxies (faint, blue and small) are consistent with young star forming galaxies which are nearly dust free. The density of Ly{alpha} emitting galaxies in the field around MRC 0316-257 is a factor of 3.3{sup +0.5}{sub -0.4} larger compared with the density of Ly{alpha} emitters at that redshift. The velocity distribution of the spectroscopically confirmed emitters has a dispersion of 640 km s{sup -1}, corresponding to a FWHM of 1510 km s{sup -1}, which is substantially smaller than the width of the narrow

  20. Electric field distribution of electron emitter surfaces

    Science.gov (United States)

    Tagawa, M.; Takenobu, S.; Ohmae, N.; Umeno, M.

    1987-03-01

    The electric field distribution of a tungsten field emitter surface and a LaB6 thermionic emitter surface has been studied. The computer simulation of electric field distribution on the emitter surface was carried out with a charge simulation method. The electric field distribution of the LaB6 thermionic emitter was experimentally evaluated by the Schottky plot. Two independent equations are necessary for obtaining local electric field and work function; the Fowler-Nordheim equation and the equation of total energy distribution of emitted electron being used to evaluate the electric field distribution of the tungsten field emitter. The experimental results agreed with the computer simulation.

  1. Deep rest-frame far-UV spectroscopy of the giant Lyman α emitter 'Himiko'

    DEFF Research Database (Denmark)

    Zabl, J.; Nørgaard-Nielsen, Hans Ulrik; Fynbo, J. P. U.;

    2015-01-01

    We present deep 10 h VLT/XSHOOTER spectroscopy for an extraordinarily luminous and extended Ly alpha emitter at z = 6.595 referred to asHimiko and first discussed by Ouchi et al., with the purpose of constraining the mechanisms powering its strong emission. Complementary to the spectrum, we discuss...

  2. Multibunch Emittance Preservation in CLIC

    CERN Document Server

    Guignard, Gilbert

    1996-01-01

    In high-frequency linacs, where the wakefields are strong, the stability of a train of bunches is critical. The beam break-up due to long range wakefields induces a decoherence of the bunch oscillations and a consequent blow-up of the effective betatron emittances of the whole train. Since the Compact Linear Collider (CLIC) study now includes several bunches per pulse, it is important to analyse numerically and theoretically this emittance blow-up. possibilities of controlling the beam break-up without upsetting the single bunch stability have been considered: first a multibunch generalization of the BNS damping principle, secondly an attenuation of the long-range fields, and thirdly an increase of the focusing in order to overconstrain the beam. Simulation codes have been written for both checking the theoretical predictions and investigating the requirements associated with a possible application to the main linac. Animated graphics make it possible to get a didactic display of the multibunch instability.

  3. A Phrygian Cap

    Directory of Open Access Journals (Sweden)

    Marie-Janne S. van Kamp

    2013-08-01

    Full Text Available A Phrygian cap is a congenital anomaly of the gallbladder with an incidence of 4%. It can simulate a mass in the liver during hepatobiliary imaging and is sometimes mistaken for pathology. A Phrygian cap, however, has no pathological significance and normally causes no symptoms. A case will be presented where a Phrygian cap was found by coincidence during surgery. The patient was operated for colon cancer with liver metastasis in segment V. He underwent a simultaneous right hemicolectomy and wedge resection of the liver lesion. During perioperative inspection, a gallbladder with a folded fundus was seen. This deformity was, in retrospective, detected on the preoperative MRI scan. The patient underwent cholecystectomy to make the wedge resection easier to perform. Otherwise, cholecystectomy for a Phrygian cap is only indicated in case of symptoms. Radiographic imaging can be helpful in narrowing the differential diagnosis. To our knowledge, there is no recent literature about the Phrygian cap and its imaging aspects. Nowadays, multiphase MRI, or multiphase CT in case of MRI contraindication, are the first choices of hepatobiliary imaging.

  4. Beam emittance measurements at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Manfred; Eddy, Nathan; Hu, Martin; Scarpine, Victor; Syphers, Mike; Tassotto, Gianni; Thurman-Keup, Randy; Yang, Ming-Jen; Zagel, James; /Fermilab

    2008-01-01

    We give short overview of various beam emittance measurement methods, currently applied at different machine locations for the Run II collider physics program at Fermilab. All these methods are based on beam profile measurements, and we give some examples of the related instrumentation techniques. At the end we introduce a multi-megawatt proton source project, currently under investigation at Fermilab, with respect to the beam instrumentation challenges.

  5. Successful treatment of cap polyposis with infliximab.

    Science.gov (United States)

    Bookman, Ian D; Redston, Mark S; Greenberg, Gordon R

    2004-06-01

    Cap polyposis is a disorder characterized by bloody diarrhea with rectosigmoid polyps covered by a cap of fibropurulent exudate. The pathogenesis is unknown, but histological features suggest that mucosal prolapse may play a role. Drug therapies are usually unsuccessful, and treatment requires sigmoid resection or, if the disease recurs after initial surgical resection, panproctocolectomy. We report the case of a 36-year-old woman with characteristic clinical, endoscopic, and histological features of cap polyposis. Investigations included normal anorectal manometry and defecography, without evidence of prolapse. The patient's disease was unresponsive to treatment with mesalamine, antibiotics, lidocaine enemas, and corticosteroids. One infusion of infliximab 5 mg/kg provided dramatic symptomatic improvement but minimal endoscopic or histological change. After 4 infliximab infusions at 8-week intervals, endoscopy of the rectum and sigmoid colon was normal, and biopsies showed complete histological resolution of the inflammatory process. Well-being with normal endoscopy and histology has been maintained at 38 months, without further treatment. It was concluded that infliximab is effective therapy for cap polyposis and avoids the requirement for surgery. No clinical evidence was obtained to support mucosal prolapse as a causative factor, but the response to infliximab suggests a role for tumor necrosis factor-alpha in the pathogenesis of this disorder. PMID:15188181

  6. Test chamber for alpha spectrometry

    Science.gov (United States)

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  7. High redshift Lya emitters: clues on the Milky Way infancy

    CERN Document Server

    Salvadori, S; Ferrara, A

    2010-01-01

    With the aim of determining if Milky Way (MW) progenitors could be identified as high redshift Lyman Alpha Emitters (LAEs) we have derived the intrinsic properties of z ~ 5.7 MW progenitors, which are then used to compute their observed Lyman-alpha luminosity, L_alpha, and equivalent width, EW. MW progenitors visible as LAEs are selected according to the canonical observational criterion, L_alpha > 10^42 erg/s and EW > 20 A. Progenitors of MW-like galaxies have L_alpha = 10^(39-43.25) erg/s, making some of them visible as LAEs. In any single MW merger tree realization, typically only 1 (out of ~ 50) progenitor meets the LAE selection criterion, but the probability to have at least one LAE is very high, P = 68%. The identified LAE stars have ages, t_* ~ 150-400 Myr at z ~ 5.7 with the exception of five small progenitors with t_* 10% of the halo very metal-poor stars [Fe/H] < -2, thus establishing a potentially fruitful link between high-z galaxies and the Local Universe.

  8. Source preparations for alpha and beta measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  9. A systematization of the half-lives for proton emitter nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Martha M.N.; Duarte, Sergio B.; Medeiros, Emil de L.; Tavares, Odilon A.P. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)]. E-mails: nicke@cbpf.br; sbd@cbpf.br; emil@cbpf.br; oaptavares@cbpf.br

    2007-07-01

    A semiempirical model based on the quantum mechanical tunnelling mechanism of alpha emission from nuclei has been extended to systematize the proton decay half-lives of all existing proton emitter nuclides. These nuclei are far from the beta stability line, near the proton drip line, and only a few experimental data are available. This semiempirical model has been well succeeded for the systematization of alpha decay half-lives, and has predicted for new candidates to alpha emission not yet detected. The purpose of the present extended systematization is to offer a useful tool capable to predict new proton emitter nuclides as well as determine their partial proton emission half-lives with good accuracy. (author)

  10. Hybrid emitter all back contact solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  11. Emittance investigation of RF photo-injector

    CERN Document Server

    Yang Mao Rong; Li Zheng; Li Ming; Xu Zhou

    2002-01-01

    A high-power laser beam illuminates a photocathode surface placed on an end wall of an RF cavity. The emitted electrons are accelerated immediately to a relativistic energy by the strong RF find in the cavity. But space charge effect induces beam emittance growth especially near the cathode where the electrons are still nonrelativistic. The author analyzes the factors which lead the transverse emittance growth and method how to resolve this problem. After introducing solenoidal focusing near the photocathode, the beam emittance growth is suppressed dramatically. The beam emittance is given also after compensation and simulation results. The measurements show these results are coincident

  12. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  13. Faint Lyα Emitters, Star-forming Galaxies, and Damped Lyα Systems

    Science.gov (United States)

    Rauch, M.; Haehnelt, M.; Bunker, A.; Becker, G.; Marleau, F.; Graham, J.; Cristiani, S.; Jarvis, M.; Lacey, C.; Morris, S.; Peroux, C.; Roettgering, H.; Theuns, T.

    2008-10-01

    We have discovered a population of faint single line emitters, likely to be identified with faint z˜ 3 Lyα emitters and with the host galaxies of damped Lyman alpha systems. The objects appear to constitute the bulk of the star-forming galaxies detected so far from the ground, and are likely to provide the gaseous reservoir from which present-day Milky way type galaxies have formed. Unlike color-selected (yman break galaxies, these objects appear to have low star-formation rates, relatively strong Lyalpha emission, and low masses, metallicities, and dust content (s.a. arXiv:0711.1354).

  14. Coefficient Alpha

    OpenAIRE

    Panayiotis Panayides

    2013-01-01

    Heavy reliance on Cronbach’s alpha has been standard practice in many validation studies. However, there seem to be two misconceptions about the interpretation of alpha. First, alpha is mistakenly considered as an indication of unidimensionality and second, that the higher the value of alpha the better. The aim of this study is to clarify these misconceptions with the use of real data from the educational setting. Results showed that high alpha values can be obtained in multidimensional scale...

  15. Performance of blasting caps

    Science.gov (United States)

    Bement, Laurence J. (Inventor); Schimmel, Morry L. (Inventor); Perry, Ronnie B. (Inventor)

    1993-01-01

    Common blasting caps are made from an aluminum shell in the form of a tube which is closed at both ends. One end, which is called the output end, terminates in a principal side or face, and contains a detonating agent which communicates with a means for igniting the detonating agent. The improvement of the present invention is a flat, steel foil bonded to the face in a position which is aligned perpendicularly to the longitudinal axis of the tube.

  16. Capping the Mortgage Interest Deduction

    OpenAIRE

    Anderson, John E.; Clemens, Jeffrey; Hanson, Andrew

    2007-01-01

    In this paper we examine the economic implications of several policy options for capping the mortgage interest deduction (MID). We extend the standard user–cost model of owner–occupied housing to include a cap on the mortgage size receiving tax–favored status. Our user–cost estimates for taxpayers with mortgages above the current–law cap are 4.41 percent higher than estimates from a model without the cap. We simulate the share of mortgage dollars that would be subject to three alternative cap...

  17. Bright Single Photon Emitter in Silicon Carbide

    Science.gov (United States)

    Lienhard, Benjamin; Schroeder, Tim; Mouradian, Sara; Dolde, Florian; Trong Tran, Toan; Aharonovich, Igor; Englund, Dirk

    Efficient, on-demand, and robust single photon emitters are of central importance to many areas of quantum information processing. Over the past 10 years, color centers in solids have emerged as excellent single photon emitters. Color centers in diamond are among the most intensively studied single photon emitters, but recently silicon carbide (SiC) has also been demonstrated to be an excellent host material. In contrast to diamond, SiC is a technologically important material that is widely used in optoelectronics, high power electronics, and microelectromechanical systems. It is commercially available in sizes up to 6 inches and processes for device engineering are well developed. We report on a visible-spectrum single photon emitter in 4H-SiC. The emitter is photostable at both room and low temperatures, and it enables 2 million photons/second from unpatterned bulk SiC. We observe two classes of orthogonally polarized emitters, each of which has parallel absorption and emission dipole orientations. Low temperature measurements reveal a narrow zero phonon line with linewidth < 0.1 nm that accounts for more than 30% of the total photoluminescence spectrum. To our knowledge, this SiC color emitter is the brightest stable room-temperature single photon emitter ever observed.

  18. Saltstone Clean Cap Formulation

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C

    2005-04-22

    The current operation strategy for using Saltstone Vault 4 to receive 0.2 Ci/gallon salt solution waste involves pouring a clean grout layer over the radioactive grout prior to initiating pour into another cell. This will minimize the radiating surface area and reduce the dose rate at the vault and surrounding area. The Clean Cap will be used to shield about four feet of Saltstone poured into a Z-Area vault cell prior to moving to another cell. The minimum thickness of the Clean Cap layer will be determined by the cesium concentration and resulting dose levels and it is expected to be about one foot thick based on current calculations for 0.1 Ci Saltstone that is produced in the Saltstone process by stabilization of 0.2 Ci salt solution. This report documents experiments performed to identify a formulation for the Clean Cap. Thermal transient calculations, adiabatic temperature rise measurements, pour height, time between pour calculations and shielding calculations were beyond the scope and time limitations of this study. However, data required for shielding calculations (composition and specific gravity) are provided for shielding calculations. The approach used to design a Clean Cap formulation was to produce a slurry from the reference premix (10/45/45 weight percent cement/slag/fly ash) and domestic water that resembled as closely as possible the properties of the Saltstone slurry. In addition, options were investigated that may offer advantages such as less bleed water and less heat generation. The options with less bleed water required addition of dispersants. The options with lower heat contained more fly ash and less slag. A mix containing 10/45/45 weight percent cement/slag/fly ash with a water to premix ratio of 0.60 is recommended for the Clean Cap. Although this mix may generate more than 3 volume percent standing water (bleed water), it has rheological, mixing and flow properties that are similar to previously processed Saltstone. The recommended

  19. Alpha indirect conversion radioisotope power source

    Energy Technology Data Exchange (ETDEWEB)

    Sychov, Maxim [TRACE Photonics Inc., 1680 West Polk, Charleston, IL 61920 (United States)], E-mail: msychov@yahoo.com; Kavetsky, Alexandr; Yakubova, Galina; Walter, Gabriel; Yousaf, Shahid; Lin, Qian; Chan, Doris; Socarras, Heather; Bower, Kenneth [TRACE Photonics Inc., 1680 West Polk, Charleston, IL 61920 (United States)

    2008-02-15

    Advantages of radioisotope-powered electric generators include long service life, wide temperature range operation and high-energy density. We report development of a long-life generator based on indirect conversion of alpha decay energy. Prototyping used 300 mCi Pu-238 alpha emitter and AlGaAs photovoltaic cells designed for low light intensity conditions. The alpha emitter, phosphor screens, and voltaic arrays were assembled into a power source with the following characteristics: I{sub sc}=14 {mu}A; U{sub oc}=2.3 V; power output -21 {mu}W. Using this prototype we have powered an eight-digit electronic calculator and wrist watch.

  20. Low Emittance X-FEL Development

    CERN Document Server

    Li, K S B; Anghel, A; Bakker, R J; Böge, M; Candel, A E; Dehler, M; Ganter, R; Gough, C; Ingold, G; Leemann, S C; Pedrozzi, M; Raguin, J Y; Rivkin, L; Schlott, V; Streun, A; Wrulich, A F

    2005-01-01

    The Paul Scherrer Institute (PSI) in Switzerland currently develops a Low-Emittance electron-Gun (LEG) based on field-emitter technology [1]. The target is a normalized transverse emittance of 5 10(-8) m rad or less. Such a source is particularly interesting for FELs that target wavelengths below 0.3 nm since it permits a reduction of the required beam-energy and hence, a reduction of the construction- and operational costs of X-ray FELs. That is, for the case that this initial low emittance can be maintained throughout the accelerator. Here we present a concept for a 0.1 nm X-FEL based on LEG, which can be located close to the Swiss Light Source (SLS). Special attention goes to the maintenance of the emittance during the process of acceleration and bunch-compression, in particular in the regimes where either space-charge forces or coherent-synchrotron radiation are of importance.

  1. TPV Systems with Solar Powered Tungsten Emitters

    International Nuclear Information System (INIS)

    A solar TPV generator development and characterization are presented. A double stage sunlight concentrator ensures 4600x concentration ratio. TPV modules based on tungsten emitters and GaSb cells were designed, fabricated and tested at indoor and outdoor conditions. The performance of tungsten emitter under concentrated solar radiation was analyzed. Emitter temperatures in the range of 1400-2000 K were measured, depending on the emitter size. The light distribution in the module has been characterized, 1x1 cm GaSb TPV cells were fabricated with the use of the Zn-diffusion and LPE technologies. The cell efficiency of 19% under illumination by a tungsten emitter (27% under spectra cut-off at λ > 1820 nm) heated up to 1900-2000 K had been derived from experimentally measured PV parameters. The series connection of PV cells was ensured by the use of BeO ceramics. The possibilities of system performance improvement are discussed

  2. Multinozzle Emitter Arrays for Nanoelectrospray Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Pan; Wang, Hung-Ta; Yang, Peidong; Wang, Daojing

    2011-06-16

    Mass spectrometry (MS) is the enabling technology for proteomics and metabolomics. However, dramatic improvements in both sensitivity and throughput are still required to achieve routine MS-based single cell proteomics and metabolomics. Here, we report the silicon-based monolithic multinozzle emitter array (MEA), and demonstrate its proof-of-principle applications in high-sensitivity and high-throughput nanoelectrospray mass spectrometry. Our MEA consists of 96 identical 10-nozzle emitters in a circular array on a 3-inch silicon chip. The geometry and configuration of the emitters, the dimension and number of the nozzles, and the micropillar arrays embedded in the main channel, can be systematically and precisely controlled during the microfabrication process. Combining electrostatic simulation and experimental testing, we demonstrated that sharpened-end geometry at the stem of the individual multinozzle emitter significantly enhanced the electric fields at its protruding nozzle tips, enabling sequential nanoelectrospray for the high-density emitter array. We showed that electrospray current of the multinozzle emitter at a given total flow rate was approximately proportional to the square root of the number of its spraying-nozzles, suggesting the capability of high MS sensitivity for multinozzle emitters. Using a conventional Z-spray mass spectrometer, we demonstrated reproducible MS detection of peptides and proteins for serial MEA emitters, achieving sensitivity and stability comparable to the commercial capillary emitters. Our robust silicon-based MEA chip opens up the possibility of a fully-integrated microfluidic system for ultrahigh-sensitivity and ultrahigh-throughput proteomics and metabolomics.

  3. Performance comparisons of low emittance lattices

    International Nuclear Information System (INIS)

    In this paper, the results of a performance analysis of several low emittance electron storage ring lattices provided by various members of the Lattice Working Group are presented. Altogether, four lattices were investigated. There are two different functions being considered for the low beam emittance rings discussed here. The first is to serve as a Damping Ring (DR), i.e., to provide the emittance damping required for a high energy linear collider. The second is to provide beams for a short wavelength Free Electron Laser (FEL), which is envisioned to operate in the wavelength region near 40 A

  4. Novel Multipin Electrode Cap System for Dry Electroencephalography.

    Science.gov (United States)

    Fiedler, P; Pedrosa, P; Griebel, S; Fonseca, C; Vaz, F; Supriyanto, E; Zanow, F; Haueisen, J

    2015-09-01

    Current usage of electroencephalography (EEG) is limited to laboratory environments. Self-application of a multichannel wet EEG caps is practically impossible, since the application of state-of-the-art wet EEG sensors requires trained laboratory staff. We propose a novel EEG cap system with multipin dry electrodes overcoming this problem. We describe the design of a novel 24-pin dry electrode made from polyurethane and coated with Ag/AgCl. A textile cap system holds 97 of these dry electrodes. An EEG study with 20 volunteers compares the 97-channel dry EEG cap with a conventional 128-channel wet EEG cap for resting state EEG, alpha activity, eye blink artifacts and checkerboard pattern reversal visual evoked potentials. All volunteers report a good cap fit and good wearing comfort. Average impedances are below 150 kΩ for 92 out of 97 dry electrodes, enabling recording with standard EEG amplifiers. No significant differences are observed between wet and dry power spectral densities for all EEG bands. No significant differences are observed between the wet and dry global field power time courses of visual evoked potentials. The 2D interpolated topographic maps show significant differences of 3.52 and 0.44% of the map areas for the N75 and N145 VEP components, respectively. For the P100 component, no significant differences are observed. Dry multipin electrodes integrated in a textile EEG cap overcome the principle limitations of wet electrodes, allow rapid application of EEG multichannel caps by non-trained persons, and thus enable new fields of application for multichannel EEG acquisition.

  5. 3rd Low Emittance Ring Workshop

    CERN Document Server

    2013-01-01

    The workshop brings together different accelerator communities working on the design of ultra low emittance lattices such as synchrotron light sources, damping rings and test facilities for linear colliders and HEP circular colliders. The aim of the workshop is to review the present development s in design of ultra low emittance lattices, the experience and the challenges with the operation of low emittance synchrotrons and the main technological problems. The merging of different accelerator communities is expected to foster ideas exchange and the collaboration both on theoretical, experimental and design issues. Areas for common R programmes will be explored. The workshop will profit from the experience of colleagues who have designed, commissioned and operated lepton ring colliders and synchrotron light sources as well as from the ones involved in future low emittance upgrade programmes of existing rings.

  6. Emittance growth in linear induction accelerators

    CERN Document Server

    Ekdahl, C A; Schulze, M E; Carlson, C A; Frayer, D K; Mostrum, C; Thoma, C H

    2014-01-01

    The Dual-Axis Radiographic Hydrotest (DARHT) facility uses bremsstrahlung radiation source spots produced by the focused electron beams from two linear induction accelerators (LIAs) to radiograph large hydrodynamic experiments driven by high explosives. Radiographic resolution is determined by the size of the source spot, and beam emittance is the ultimate limitation to spot size. On the DARHT Axis-II LIA we measure an emittance higher than predicted by theoretical simulations, and even though this axis produces sub-millimeter source spots, we are exploring ways to improve the emittance. Some of the possible causes for the discrepancy have been investigated using particle-in-cell (PIC) codes, although most of these are discounted based on beam measurements. The most likely source of emittance growth is a mismatch of the beam to the magnetic transport, which can cause beam halo.

  7. Monochromatic gamma emitter for low energy quanta

    CERN Document Server

    Tomova, Z R; Mironova, S A

    2004-01-01

    The possibility of creating of a monochromatic gamma emitter of low energy quanta is analyzed. The idea is based on Daning's scheme. Except for purely scientific problems the monochromator is actual for therapy of wide range of diseases.

  8. Low emittance upgrade for CANDLE project

    CERN Document Server

    Zanyan, G S

    2015-01-01

    To improve the performance of CANDLE synchrotron light source and stay competitive with recently proposed low emittance upgrade programs in the world we have developed new low emittance lattices for CANDLE booster and storage ring. These lattices have been designed taking into account the new developments in magnet fabrication technology and the multi-bend achromat concept. The main design considerations, the linear and non-linear beam dynamics aspects of the modified lattices are presented.

  9. ATLAS end-cap detector

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Three scientists from the Institute of Nuclear Phyiscs at Novossibirsk with one of the end-caps of the ATLAS detector. The end-caps will be used to detect particles produced in the proton-proton collisions at the heart of the ATLAS experiment that are travelling close to the axis of the two beams.

  10. A low-emittance lattice for SPEAR

    Science.gov (United States)

    Safranek, J.; Wiedemann, H.

    1992-08-01

    The design and implementation of a low emittance lattice for the SPEAR storage ring including measurements of the performance of the lattice are presented [J. Safranek, Ph.D. thesis, Stanford University, 1991]. The low emittance lattice is designed to optimize the performance of SPEAR as a synchrotron radiation source while keeping SPEAR hardware changes at a minimum. The horizontal emittance of the electron beam in the low emittance lattice is reduced by a factor of 4 from the previous lattice. This reduces the typical horizontal source size and divergence of the photon beams by a factor of 2 each and increases the photon beam brightness. At 3 GeV the horizontal emittance is 129π nm rad, which makes the low emittance lattice the lowest emittance, running synchrotron radiation source in the world in the 1.5 to 4.0 GeV energy range for the emittance scaled to 3 GeV. The measured vertical emittance was reduced to half that typically seen at SPEAR in the past. The brightness of the photon beams was further increased by reducing βy at the insertion devices to 1.1 m and reducing the energy dispersion at the insertion devices by more than a factor of 2 on average. The horizontal dispersion at the rf cavities was reduced by a factor of nearly 4 which gives much less problems with synchrobetatron resonances. The dynamic and physical apertures of the lattice are large, giving long beam lifetimes and easy injection of electrons. The measurements of the linear optics and intensity dependent phenomena gave reasonable agreement with the design. The overall performance of the machine was very good. Injection rates of 10 to 20 mA/min and larger were achieved routinely, and 100 mA total current was stored. Repeated ramping of stored beam from the injection energy of 2.3 GeV to the running energy of 3.0 GeV was achieved with very little beam loss. This low emittance configuration is expected to be the operating configuration for SPEAR starting in January 1992.

  11. Remote Optical Detection of Alpha Radiation

    International Nuclear Information System (INIS)

    Alpha emitting radiation sources are typically hard to detect with conventional detectors due to the short range of alpha particles in the air. However, previous studies have shown that remote detection of alpha radiation is possible by measuring the ionization-induced fluorescence of air molecules. The alpha-induced ultraviolet (UV) light is mainly emitted by molecular nitrogen and its fluorescence properties are well known. The benefit of this method is the long range of UV photons in the air. Secondly, the detection is possible also under a strong beta and gamma radiation backgrounds as they do not cause localized molecular excitation. In this work, the optical detection was studied using two different detection schemes; spectral separation of fluorescence from the background lighting and coincidence detection of UV photons originating from a single radiative decay event. Our spectrally integrated measurements have shown that one alpha decay event yields up to 400 fluorescence photons in the air and all these UV photons are induced in a 5 ns time-window. On the other hand, the probability of a background coincidence event in 5 ns scale is very rare compared to the number of background photons. This information can be applied in fluorescence coincidence filtering to discriminate the alpha radiation initiated fluorescence signal from much more intense background lighting. A device called HAUVA (Handheld Alpha UV Application) was built during this work for demonstration purposes. HAUVA utilizes spectral filtering and it is designed to detect alpha emitters from a distance of about 40 cm. Using specially selected room lighting, the device is able to separate 1 kBq alpha emitter from the background lighting with 1 second integration time. (author)

  12. Polar caps in the presence of an induction field

    CERN Document Server

    Jones, P B

    2015-01-01

    Following the early paper of Goldreich & Julian (1969), polar-cap models have usually assumed that the closed sector of a pulsar magnetosphere corotates with the neutron star. Recent work by Melrose & Yuen has been a reminder that in an oblique rotator, the induction field arising from the time-varying magnetic flux density cannot be completely screened. The principal consequence is that the plasma does not corotate with the star. Here it is shown that the physics of the polar cap is not changed at the altitudes of the radio emission source. But the presence of a plasma drift velocity in the corotating frame of reference does provide a mechanism whereby the net charge of the star can be maintained within a stable band of values. It also shows directly how electron injection and acceleration occur in the outer gap of the magnetosphere. It is consistent with radio-loud pulsars in the Fermi LAT catalogue of gamma-emitters all having positive polar-cap charge density.

  13. Buffett's Alpha

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Kabiller, David; Heje Pedersen, Lasse

    Berkshire Hathaway has realized a Sharpe ratio of 0.76, higher than any other stock or mutual fund with a history of more than 30 years, and Berkshire has a significant alpha to traditional risk factors. However, we find that the alpha becomes insignificant when controlling for exposures to Betting...

  14. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  15. Variable emittance behavior of smart radiative coating

    Science.gov (United States)

    Guo, Li; Fan, Desong; Li, Qiang

    2016-02-01

    Smart radiative coating on yttria stabilized zirconia (YSZ) substrate was prepared by the sol-gel La{}1-xSr x MnO3 (x = 0.125, 0.175 and 0.2) nanoparticles and the binder composed of terpineol and ethyl cellulose. The crystallized structure, grain size, chemical compositions, magnetization and the surface morphology were characterized. The thermal radiative properties of coating in the infrared range was evaluated from infrared reflectance spectra at various temperatures. A single perovskite structure is detected in sol-gel nanoparticles with size 200 nm. Magnetization measurement reveals that room temperature phase transition samples can be obtained by appropriate Sr substitution. The influence of surface conditions and sintering temperature on the emittance of coating was observed. For rough coatings with root-mean-square roughness 640 nm (x = 0.125) and 800 nm (x = 0.175) , its emittance increment is 0.24 and 0.26 in in the temperature range of 173-373 K. Increasing sintering temperature to 1673 K, coating emittance variation improves to 0.3 and 0.302 respectively. After mechanical polishing treatment, the emittance increment of coatings are enhanced to 0.31 and 0.3, respectively. The results suggested that the emittance variation can be enhanced by reducing surface roughness and increasing sintering temperature of coating.

  16. ETAII 6 MEV PEPPERPOT EMITTANCE MEASUREMENT

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A C; Richardson, R; Weir, J

    2004-10-18

    We measured the beam emittance at the ETAII accelerator using a pepper-pot diagnostic at nominal parameters of 6 MeV and 2000 Amperes. During the coarse of these experiments, a ''new tune'' was introduced which significantly improved the beam quality. The source of a background pedestal was investigated and eliminated. The measured ''new tune'' emittance is {var_epsilon}= 8.05 {plus_minus} 0. 53 cm - mr or a normalized emittance of {var_epsilon}{sub n} = 943 {plus_minus} 63 mm - mr In 1990 the ETAII programmatic emphasis was on free electron lasers and the paramount parameter was whole beam brightness. The published brightness for ETAII after its first major rebuild was J = 1 - 3 x 10{sup 8} A/(m - rad){sup 2} at a current and energy of 1000-1400 Amperes and 2.5 MeV. The average normalized emittance derived from table 2 of that report is 864 mm-mr corresponding to a real emittance of 14.8 cm-mr.

  17. ATLAS - End-Cap calorimeter

    CERN Multimedia

    2006-01-01

    The End-cap calorimeter was moved with the help of the rails and this calorimeter will measure the energy of particles close to the beam axis when protons collide. Cooling is important for maximum detector efficiency.

  18. Researchers dodge UK migration cap

    Science.gov (United States)

    Dacey, James

    2011-03-01

    Research scientists are among those to be prioritized under the UK government's new immigration rules that will impose an annual cap on the number of work visas issued to those from outside the European Union (EU).

  19. Genetics Home Reference: cap myopathy

    Science.gov (United States)

    ... or a spine that curves to the side ( scoliosis ). The name cap myopathy comes from characteristic abnormal ... health conditions: Diagnostic Tests Drug Therapy Surgery and Rehabilitation Genetic Counseling Palliative Care Related Information How are ...

  20. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  1. Performance comparisons of low emittance lattices

    International Nuclear Information System (INIS)

    The results of a performance analysis of four low emittance electron storage ring lattices provided to the authors by various members of the Lattice Working Group is presented. Altogether, four lattices were investigated. The beam energies of the four lattices are, respectively, 1.1, 2, 3, 4 GeV). A brief summary of the lattice parameters relevant to this study is given. The performance issues studied include an estimation of the longitudinal emittance expected for each lattice based on the effects of the longitudinal microwave instability, an estimation of the transverse emittance growth of the (required) dense bunches under the influence of intrabeam scattering (IBS), and an estimate of the Touschek lifetime. The analysis described here has been carried out with the LBL accelerator physics code ZAP

  2. Research on Radar Emitter Attribute Recognition Method

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In order to solve emitter recognition problems in a practical reconnaissance environment, attribute mathematics is introduced. The basic concepts and theory of attribute set and attribute measure are described in detail. A new attribute recognition method based on attribute measure is presented in this paper. Application example is given, which demonstrates this new method is accurate and effective. Moreover, computer simulation for recognizing the emitter purpose is selected, and compared with classical statistical pattern recognition through simulation. The excellent experimental results demonstrate that this is a brand-new attribute recognition method as compared to existing statistical pattern recognition techniques.

  3. Coupling single emitters to quantum plasmonic circuits

    CERN Document Server

    Huck, Alexander

    2016-01-01

    In recent years the controlled coupling of single photon emitters to propagating surface plasmons has been intensely studied, which is fueled by the prospect of a giant photonic non-linearity on a nano-scaled platform. In this article we will review the recent progress on coupling single emitters to nano-wires towards the construction of a new platform for strong light-matter interaction. The control over such a platform might open new doors for quantum information processing and quantum sensing at the nanoscale, and for the study of fundamental physics in the ultra-strong coupling regime.

  4. Quadrupole Transfer Function for Emittance Measurement

    CERN Document Server

    Cameron, Peter; Jansson, Andreas; Tan, Cheng-Yang

    2008-01-01

    Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.

  5. Alpha fetoprotein

    Science.gov (United States)

    Fetal alpha globulin; AFP ... Greater than normal levels of AFP may be due to: Cancer in testes , ovaries, biliary (liver secretion) tract, stomach, or pancreas Cirrhosis of the liver Liver cancer ...

  6. The island of alpha activity close to the double magic nucleus 100Sn

    International Nuclear Information System (INIS)

    Up to now, 14 alpha emitters have been identified among the neutrondeficient isotopes of Te, I, Xe and Cs. None of the nine formulae of 1975 mass predictions can reproduce the Q-values of all these alpha emitters. Nevertheless, one can say that some good estimates are obtained by using the masses given by: Myers; Groote-Hilf-Takahashi, Liran Zeldes; Jaenecke-Eynon and Jaenecke. If the Q-value is known, our semiempirical formula, based on the fission theory of alpha decay, allow to obtain the best estimates of the partial life-times. This relationship is used to predict new alpha emitters with atomic numbers Z = 52-61. (authors)

  7. Human skeletal uptake of natural alpha radioactivity from {sup 210}Pb-supported {sup 210}Po

    Energy Technology Data Exchange (ETDEWEB)

    Oyedepo, A.C

    1998-06-01

    This thesis contributes to increasing knowledge on the dosimetry of natural alpha-particle radiation in skeletal tissues, particularly in utero, and associated risks of malignancy. Alpha-particle radiation is an established aetiological factor of cancer. In the human body, polonium-210 decayed from skeletal lead-210 ({sup 210}Pb/{sup 210}Po) is the predominant natural alpha-emitter. {sup 210}Pb displaces calcium (Ca) in mineral hydroxyapatite, especially during periods of rapid bone growth and remodelling when Ca is laid down. It was therefore necessary to study alpha activity uptake and calcification concurrently within bone. Human studies were undertaken on: fetal vertebrae, 17 - 42 weeks of gestation, 74 samples; adult vertebrae, 40 - 95 years, 40 samples; and adult ribs, 20 - 95 years, 51 samples. Specimens were unconcentrated and weighed <5 g each. TASTRAK alpha-particle autoradiography was used to assess the bone activity concentration and spatial microdistribution of {sup 210}Pb/{sup 210}Po. Alpha track data were resolved by specially written software named SPATS (Selection Program for Analysing Track Structures). Ca and phosphorus (P) were biochemically determined. Results were examined for trends in bone type, gender and chronological ageing in humans. The main research findings were: 1) The Ca content of fetal vertebrae increased linearly at a weekly rate of 0.2g Ca 100 g{sup -1} wet bone (typical values of 2, 4, 6 g 100 g{sup -1} at 16, 26 and 36 weeks). 2) The P concentration also increased with advancing fetal age. 3) The Ca:P bone weight ratio rose from 1.7 to 2.2 by 32 gestational weeks. 4) The overall range in bone {sup 210}Pb/{sup 210}Po alpha activity was 0.25 - 1.1 Bq kg{sup -1} with correlation between activity concentration and fetal age (0.47 {+-} 0.05 Bq kg{sup -1} for 17 - 26 weeks, 0.67 {+-} 0.04 Bq kg{sup -1} for 32 - 42 weeks). 5) The correlation between increased alpha radioactivity and increased Ca concentration approximating to 0

  8. Emittance growth from electron beam modulation

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M.

    2009-12-01

    In linac ring colliders like MeRHIC and eRHIC a modulation of the electron bunch can lead to a modulation of the beam beam tune shift and steering errors. These modulations can lead to emittance growth. This note presents simple formulas to estimate these effects which generalize some previous results.

  9. Longitudinal emittance measurements at REX-ISOLDE

    CERN Document Server

    Fraser, M A; Jones, R.M.; Jones, R M; Pasini, M; Posocco, P A; Voulot, D; Wenander, F

    2012-01-01

    We report on measurements of the longitudinal emittance at the Radioactive ion beam EXperiment (REX) at ISOLDE, CERN. The rms longitudinal emittance was measured as 0.34 ± 0.08 π ns keV/u at the output of the RFQ and as 0.36 ± 0.04π ns keV/u in front of the third 7-gap split-ring resonator (7G3) using the three-gradient technique; systematic errors are not included but are estimated at approximately 10%. The 86% emittance was measured a factor of approximately 4.4 times larger than the rms emittance at 1.48 ± 0.2 and 1.55 ± 0.12π ns keV/u at the RFQ and 7G3, respectively. The REX switchyard magnet was used as a spectrometer to analyse the energy spread of the beam as it was manipulated by varying the voltage of the rebuncher (ReB) and 7G3 cavities operating at non-accelerating phases. The transfer matrix for a multi-gap bunching cavity is derived and suitably truncated to allow for the accurate reconstruction of the beam parameters from measurement. The technique for measuring the energy spread was rig...

  10. THz imaging system with the IJJ emitter

    Science.gov (United States)

    Tsujimoto, Manabu; Minami, Hidetoshi; Sawamura, Masashi; Delfanazari, Kaveh; Yamamoto, Takashi; Kashiwagi, Takanari; Kadowaki, Kazuo

    2011-03-01

    The intrinsic Josephson junction (IJJ) emitter consisted of thousands of IJJs uniformly stacked in single crystalline high-Tc superconductor Bi 2 Sr 2 CaCu 2 O8 + δ (Bi-2212) [L. Ozyuzer et al., Science 318, (2007) 1291.] is expected to be a novel source of the continuous terahertz electromagnetic waves (THz-waves). The maximum emission power of tens of microwatts recently obtained with the mesa structure of IJJs seems to be sufficient to make use of the IJJ emitter for some practical applications such as THz imaging. According to the cavity resonance condition, we can control the radiation frequency by changing the geometrical size of the mesa. In this study, we develop the THz imaging system with IJJ emitter. In the presentation, we will show some transparent images of standard specimens obtained by the raster scanning method. Also, we will mention some problems to be solved for the future applications of the IJJ emitter. CREST-JST, WPI-MANA, Strategic Initiative A (University of Tsukuba).

  11. Innovative Field Emitters for High-Voltage Electronic Devices

    Science.gov (United States)

    Sominski, G. G.; Sezonov, V. E.; Taradaev, E. P.; Tumareva, T. A.; Zadiranov, Yu. M.; Kornishin, S. Yu.; Stepanova, A. N.

    2015-12-01

    We describe multitip field emitters with protective coatings, which were developed in Peter the Great St. Petersburg Polytechnic University. The coatings ensure long-term operation of the emitters under high currents and technical vacuum. Innovative multi-layer emitters composed of contacting nanolayers of materials with different work functions are presented as well. The possibility by using the developed emitters in high-voltage electronic devices is demonstrated.

  12. Creation of polar cap patches

    Science.gov (United States)

    Hosokawa, K.; Taguchi, S.; Ogawa, Y.

    2014-12-01

    Polar cap patches, which are islands of enhanced plasma density drifting anti-sunward, are one of the outstanding phenomena in the polar cap F region ionosphere. In the last decade, data from all-sky airglow imagers have been extensively used for better understanding the propagation of patches in the central polar cap region. But still, it has been rather difficult to capture the birth of patches in their generation region near the dayside cusp, because, in most places, the dayside part of the polar cap ionosphere is sunlit even in winter. In Longyearbyen (78.1N, 15.5E), Norway, however, optical observations are possible near the dayside cusp region in a limited period around the winter solstice. This enables us to directly image how polar cap patches are born in the cusp. In this paper, we present a few intervals of daytime optical observations, during which polar cap patches were generated within the field-of-view of an all-sky imager in Longyearbyen. During all the intervals studied here, we identified several signatures of poleward moving auroral forms (PMAF) in the equatorward half of the field-of-view, which are known as ionospheric manifestations of dayside reconnection. Interestingly, patches were directly produced from such poleward moving auroral signatures and propagated poleward along the anti-sunward convection near the cusp. In the literature, Lorentzen et al. (2012) first reported such a direct production of patches from PMAFs. During the current observations, however, we succeeded in tracking the propagation of patches until they reached the poleward edge of the field-of-view of the imager. This confirms that the faint airglow structures produced from PMAFs were actually transported for a long distance towards the central polar cap area; thus, polar cap patches were produced. From this set of observations, we suggest that polar cap patches during moderately disturbed conditions (i.e, non-storm time conditions) can be directly produced by the

  13. RF Emitter geolocation using PDOA algorithms and UAVs - A strategy from emitter detection to location prediction

    OpenAIRE

    Engebråten, Sondre Andreas

    2015-01-01

    In this thesis, I explored strategies for locating an RF emitter. Expanding on an idea conceived at Norwegian Defence Research Establishment (FFI), of using small, cheap RSS sensors and Unmanned Aerial Vehicles (UAVs) to search for unknown RF emitters. Cheap and simple, will in most cases, mean that some property of the system suffers, compared to more complicated and expensive systems. This thesis attempts to circumvent these issues by using multiple sensors instead of one ...

  14. What is so super about super-emitters? Characterizing methane high emitters from natural gas infrastructure

    Science.gov (United States)

    Zavala Araiza, D.; Lyon, D. R.; Alvarez, R.; Harriss, R. C.; Palacios, V.; Hamburg, S.

    2015-12-01

    Methane emissions across the natural gas supply chain are dominated at any one time by a few high-emitters (super-emitters or fat-tail of the distribution), often underrepresented in published datasets used to construct emission inventories. Characterization of high-emitters is essential for improving emission estimates based on atmospheric data (top-down) and emission inventories (bottom-up). The population of high-emitters (e.g. 10-20% of sites that account for 80-90% of the emissions) is temporally and spatially dynamic. As a consequence, it is challenging to design sampling methods and construct estimates that accurately represent their frequency and magnitude of emissions. We present new methods to derive facility-specific emission distribution functions that explicitly integrate the influence of the relatively rare super-emitters. These methods were applied in the Barnett Shale region to construct a custom emission inventory that is then compared to top-down emission estimates for the region. We offer a methodological framework relevant to the design of future sampling campaigns, in which these high-emitters are seamlessly incorporated to representative emissions distributions. This framework can be applied to heterogeneous oil and gas production regions across geographies to obtain accurate regional emission estimates. Additionally, we characterize emissions relative to the fraction of a facility's total methane throughput; an effective metric to identify sites with excess emissions resulting from avoidable operating conditions, such as malfunctioning equipment (defined here as functional super-emitters). This work suggests that identifying functional super-emitters and correcting their avoidable operating conditions would result in significant emission reductions. However, due to their spatiotemporal dynamic behavior, achieving and maintaining uniformly low emissions across the entire population of sites will require mitigation steps (e.g. leak detection

  15. Crystal structure of Bacillus anthracis transpeptidase enzyme CapD.

    Energy Technology Data Exchange (ETDEWEB)

    Wu, R.; Richter, S.; Zhang, R.; Anderson, V. J.; Missiakas, D.; Joachimiak, A.; Biosciences Division; Univ. of Chicago

    2009-09-04

    Bacillus anthracis elaborates a poly-{gamma}-d-glutamic acid capsule that protects bacilli from phagocytic killing during infection. The enzyme CapD generates amide bonds with peptidoglycan cross-bridges to anchor capsular material within the cell wall envelope of B. anthracis. The capsular biosynthetic pathway is essential for virulence during anthrax infections and can be targeted for anti-infective inhibition with small molecules. Here, we present the crystal structures of the {gamma}-glutamyltranspeptidase CapD with and without {alpha}-l-Glu-l-Glu dipeptide, a non-hydrolyzable analog of poly-{gamma}-d-glutamic acid, in the active site. Purified CapD displays transpeptidation activity in vitro, and its structure reveals an active site broadly accessible for poly-{gamma}-glutamate binding and processing. Using structural and biochemical information, we derive a mechanistic model for CapD catalysis whereby Pro{sup 427}, Gly{sup 428}, and Gly{sup 429} activate the catalytic residue of the enzyme, Thr{sup 352}, and stabilize an oxyanion hole via main chain amide hydrogen bonds.

  16. The alpha immunotherapy - A successful solution in cancer treatment

    International Nuclear Information System (INIS)

    Full text: Radiation has been used in cancer therapy for many years. While, in the past the treatment involved mainly use of relatively low energy beta-emitters, more recently it was shown that isotopes emitting alpha particles have been more effective and selective against blood-borne cancers, widespread tumors and residual cells remaining after surgical intervention. This study shows that radioimmunotherapy (RIT) with α emitters may be therapeutically more effective than RIT with conventional β emitters. In the process of designing and developing the radioimmunotherapy procedures, the selection of the isotope is a major factor. This selection depends on a number of criteria and parameters, affecting usefulness and feasibility. Usefulness is directly related to the radiological performance of the ionising radiation in relation to tissue and its morphology, with a major distinction between the effects of alpha and beta-particles. Usefulness is also related to the pharmacodynamic performance of the isotope-carrier (e.g. antibody) complex, where the proper choice of isotope radiodecay half-life is essential. Feasibility depends on availability of the components in the isotope-ligand-carrier complex, and also on convenience and safety aspects in the preparation and the handling of the materials as well as in their application in patients. Alpha immunotherapy is based on emission of alpha particles by radionuclides. Due to its short physical t1/2, 213Bi appears to be especially suitable for use in conjunction with fast-clearing fragments; its 440-keV α emission also can be used for quantitation by external scintigraphy. Bismuth-213, a short-lived alpha particle emitting radionuclide, is generated from the decay of 225Ac, which has a half-life of 10 days. The development of a clinical 225Ac/213Bi generator and the preparation of a 213Bi radiolabeled antibody for radioimmunotherapy of leukemia is reported. Alpha emitting radionuclides are amongst the most promising

  17. The North Zealand CAP Monitor

    DEFF Research Database (Denmark)

    Nielsen, Minna; Ravn, Pernille; Notander Clausen, Lise;

    2016-01-01

    nurses and two senior doctors. Direct observations of the clinical processes revealed problems of coordination, complex disease trajectories that did not fit with the pneumonia pathway, unclear guidelines and variation in their interpretation. Intervention We designed a measurement system to monitor...... patients with CAP and effects of interventions to improve the quality of their care. Based on current literature we defined and tested a set of indicators and designed an audit form, a database and a dashboard for presenting the results. Two nurses monthly audited randomly selected files of patients...... steps of the pneumonia pathway. Lessons learnt Quality of care for CAP was worse than expected. Defining and agreeing upon a set of indicators was difficult and time consuming but useful to improve our understanding of how care for CAP was in routine clinical practice. Several indicators we initially...

  18. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10-6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  19. Studying fringe field effect of a field emitter array

    International Nuclear Information System (INIS)

    Field emitter arrays on heavy As-doped Si wafer are studied in vacuum nanoelectronics diode configuration. Different shapes of emitters are considered: cone-shaped point-emitters and cylinder-shaped sharp-edge-emitters are compared. Micro scale field enhancement factor on the edge of cylindrical emitter was calculated via home-developed Matlab application and the results are presented. Two types of anode geometry are proposed: plane anode and spherical anode. Experimental and modelling results of surface electric field distribution are presented. The spherical shape of anode allows higher voltage (and higher field emission current) without destructive arcs risk

  20. $\\alpha_s$ review (2016)

    CERN Document Server

    d'Enterria, David

    2016-01-01

    The current world-average of the strong coupling at the Z pole mass, $\\alpha_s(m^2_{Z}) = 0.1181 \\pm 0.0013$, is obtained from a comparison of perturbative QCD calculations computed, at least, at next-to-next-to-leading-order accuracy, to a set of 6 groups of experimental observables: (i) lattice QCD "data", (ii) $\\tau$ hadronic decays, (iii) proton structure functions, (iv) event shapes and jet rates in $e^+e^-$ collisions, (v) Z boson hadronic decays, and (vi) top-quark cross sections in p-p collisions. In addition, at least 8 other $\\alpha_s$ extractions, usually with a lower level of theoretical and/or experimental precision today, have been proposed: pion, $\\Upsilon$, W hadronic decays; soft and hard fragmentation functions; jets cross sections in pp, e-p and $\\gamma$-p collisions; and photon F$_2$ structure function in $\\gamma\\,\\gamma$ collisions. These 14 $\\alpha_s$ determinations are reviewed, and the perspectives of reduction of their present uncertainties are discussed.

  1. An ultracold low emittance electron source

    CERN Document Server

    Xia, G; Murray, A J; Bellan, L; Bertsche, W; Appleby, R B; Mete, O; Chattopadhyay, S

    2014-01-01

    Ultracold atom-based electron sources have recently been proposed as an alternative to the conventional photo-injectors or thermionic electron guns widely used in modern particle accelerators. The advantages of ultracold atom-based electron sources lie in the fact that the electrons extracted from the plasma (created from near threshold photo-ionization of ultracold atoms) have a very low temperature, i.e. down to tens of Kelvin. Extraction of these electrons has the potential for producing very low emittance electron bunches. These features are crucial for the next generation of particle accelerators, including free electron lasers, plasma-based accelerators and future linear colliders. The source also has many potential direct applications, including ultrafast electron diffraction (UED) and electron microscopy, due to its intrinsically high coherence. In this paper, the basic mechanism of ultracold electron beam production is discussed and our new research facility for an ultracold, low emittance electron s...

  2. From Blogs to Bottle Caps

    Science.gov (United States)

    Edinger, Ted

    2012-01-01

    There is a wonderful community of art educators connecting a once-isolated profession through blogging. Art educators around the world are sharing ideas and communicating with their peers through this amazing resource. In this article, the author describes the bottle cap mural at Tulip Grove Elementary School which was inspired by this exchange of…

  3. Discovery of a Giant Lya Emitter Near the Reionization Epoch

    Energy Technology Data Exchange (ETDEWEB)

    Ouchi, Masami; Ono, Yoshiaki; Egami, Eiichi; Saito, Tomoki; Oguri, Masamune; McCarthy, Patrick J.; Farrah, Duncan; Kashikawa, Nobunari; Momcheva, Ivelina; Shimasaku, Kazuhiro; Nakanishi, Kouichiro; Furusawa, Hisanori; Akiyama, Masayuki; Dunlop, James S.; Mortier, Angela M.J.; Okamura, Sadanori; Hayashi, Masao; Cirasuolo, Michele; Dressler, Alan; Iye, Masanori; Jarvis, Matt.J.

    2008-08-01

    We report the discovery of a giant Ly{alpha} emitter (LAE) with a Spitzer/IRAC counterpart near the reionization epoch at z = 6.595. The giant LAE is found from the extensive 1 deg{sup 2} Subaru narrow-band survey for z = 6.6 LAEs in the Subaru/XMM-Newton Deep Survey (SXDS) field, and subsequently identified by deep spectroscopy of Keck/DEIMOS and Magellan/IMACS. Among our 207 LAE candidates, this LAE is not only the brightest narrow-band object with L(Ly{alpha}) = 3.9 {+-} 0.2 x 10{sup 43} erg s{sup -1} in our survey volume of 10{sup 6} Mpc{sup 3}, but also a spatially extended Ly{alpha} nebula with the largest isophotal area whose major axis is at least {approx_equal} 3-inches. This object is more likely to be a large Ly{alpha} nebula with a size of {approx}> 17-kpc than to be a strongly-lensed galaxy by a foreground object. Our Keck spectrum with medium-high spectral and spatial resolutions suggests that the velocity width is v{sub FWHM} = 251 {+-} 21 km s{sup -1}, and that the line-center velocity changes by {approx_equal} 60 km s{sup -1} in a 10-kpc range. The stellar mass and star-formation rate are estimated to be 0.9-5.0 x 10{sup 10}M{sub {circle_dot}} and > 34 M{sub {circle_dot}}yr{sup -1}, respectively, from the combination of deep optical to infrared images of Subaru, UKIDSS-Ultra Deep Survey, and Spitzer/IRAC. Although the nature of this object is not yet clearly understood, this could be an important object for studying cooling clouds accreting onto a massive halo, or forming-massive galaxies with significant outflows contributing to cosmic reionization and metal enrichment of inter-galactic medium.

  4. Large-area lanthanum hexaboride electron emitter

    Science.gov (United States)

    Goebel, D. M.; Hirooka, Y.; Sketchley, T. A.

    1985-09-01

    The characteristics of lanthanum-boron thermionic electron emitters are discussed, and a large-area, continuously operating cathode assembly and heater are described. Impurity production and structural problems involving the support of the LaB6 have been eliminated in the presented configuration. The performance of the cathode in a plasma discharge, where surface modification occurs by ion sputtering, is presented. Problem areas which affect lifetime and emission current capability are discussed.

  5. Emittance growths in resonance crossing at FFAGs

    Energy Technology Data Exchange (ETDEWEB)

    Ng, K.Y.; /Fermilab; Pang, X.; Wang, F.; Wang, X.; Lee, S.Y.; /Indiana U.

    2007-10-01

    Scaling laws of the emittance growth for a beam crossing the 6th-order systematic space-charge resonances and the random-octupole driven 4th-order resonance are obtained by numerical multi-particle simulations. These laws can be important in setting the minimum acceleration rate and maximum tolerable resonance strength for the design of non-scaling fixed-field alternating gradient accelerators.

  6. Studies on anodic oxide coating with low absorptance and high emittance on aluminum alloy 2024

    Energy Technology Data Exchange (ETDEWEB)

    Siva Kumar, C. [Department of Post-graduate studies in Chemistry, Central College, Bangalore (India); Sharma, A.K. [Thermal Process Section, ISRO Satellite Centre, Vimanapura Post, Bangalore (India); Mahendra, K.N.; Mayanna, S.M. [Department of Post-graduate studies in Chemistry, Central College, Bangalore (India)

    2000-01-01

    Anodization of AA 2024 in sulfuric acid bath containing glycerol, lactic acid and ammonium metavenadate has been studied to develop white anodic oxide coating. Investigation on the influence of various operating parameters - coating thickness, current density and ammonium metavenadate concentration on the optical properties was carried out to optimize the process. Infrared, atomic absorption spectroscopic techniques and scanning electron micrograph were used to characterize the coating. The obtained oxide coating provides a ratio of solar absorptance ({alpha}) to infrared emittance ({epsilon}), as low as 0.2. The optical properties and hardness values measured under optimum experimental conditions support its use as a thermal control coating.

  7. Direct Alpha Analysis for Forensic Samples (DAAFS)

    International Nuclear Information System (INIS)

    The goal of the DAAFS project is to deliver a field deployable direct alpha sample spectrometry system. This system is designed to rectify current gaps in pure alpha emitting material detection. The system comprises, firstly, an evaluation of multiple innovative methods for rapid on-site sample collection of difficult to detect alpha RN contamination. Secondly, the incorporation of an experimental alpha spectrometry analysis software suite, 'ADAM', is provided for performing the required on-site deconvolution of the complex alpha spectra arising from the direct sample measurement. Software simulation of collected alpha spectra will be handled by 'AASI', which will simulate alpha spectra as a training and analysis verification tool. Thirdly, a Concept of Operations (ConOps) for the system implementation in RN field teams is included. This combination of the swipe methodology, advanced swipe treatment equipment, mobile field laboratories, and the state of the art analysis software suite will provide RN response teams with the capability to identify and rapidly (i.e., hours as opposed to days) quantify low activity and difficult to detect alpha emitters. Further expert analysis support is available to field teams by sharing of raw spectral data via email with off-site laboratories. The proposed system provides the solution to this identified capability gap, specifically, a field-deployable real-time alpha detection system. The system comprises: a non-destructive particle sampler, standardized swipe sampling methods, a self-contained field alpha spectrometry system and an integrated data management/communications tool allowing for real-time raw-data tracking and data sharing. This system also provides responders with the type/quantity of RN material for improved safeguards, forensics, and contamination mitigation applications. (author)

  8. On the Diffuse Lyman-alpha Halo Around Lyman-alpha Emitting Galaxies

    CERN Document Server

    Lake, Ethan; Cen, Renyue; Sadoun, Raphael; Momose, Rieko; Ouchi, Masami

    2015-01-01

    Ly$\\alpha$ photons scattered by neutral hydrogen atoms in the circumgalactic media or produced in the halos of star-forming galaxies are expected to lead to extended Ly$\\alpha$ emission around galaxies. Such low surface brightness Ly$\\alpha$ halos (LAHs) have been detected by stacking Ly$\\alpha$ images of high-redshift star-forming galaxies. We study the origin of LAHs by performing radiative transfer modeling of nine $z=3.1$ Lyman-Alpha Emitters (LAEs) in a high resolution hydrodynamic galaxy formation simulation. We develop a method of computing the mean Ly$\\alpha$ surface brightness profile of each LAE by effectively integrating over many different observing directions. Without adjusting any parameters, our model yields an average Ly$\\alpha$ surface brightness profile in remarkable agreement with observations. We find that observed LAHs can not be accounted for solely by photons originating from the central LAE and scattered to large radii by hydrogen atoms in the circumgalactic gas. Instead, Ly$\\alpha$ em...

  9. Afterglow-reabsorbed H/sub alpha/ line delay effect in an expanding laser plasma

    Energy Technology Data Exchange (ETDEWEB)

    Derzhiev, V.I.; Zhidkov, A.G.; Maiorov, S.A.; Yakovlenko, S.I.

    1987-11-28

    The absorption of H/sub ..cap alpha../ line radiation is shown to lead to delay and even to non-monotonic afterglowing if observed along the 'line' of the expanding laser plasma. This makes it possible to explain the emission character of the H/sub ..cap alpha../ line of the O VIII ion (lambda = 10.2 nm) in experiments with 'Novette' set-ups.

  10. Emissivity Tuned Emitter for RTPV Power Sources

    Energy Technology Data Exchange (ETDEWEB)

    Carl M. Stoots; Robert C. O' Brien; Troy M. Howe

    2012-03-01

    Every mission launched by NASA to the outer planets has produced unexpected results. The Voyager I and II, Galileo, and Cassini missions produced images and collected scientific data that totally revolutionized our understanding of the solar system and the formation of the planetary systems. These missions were enabled by the use of nuclear power. Because of the distances from the Sun, electrical power was produced using the radioactive decay of a plutonium isotope. Radioisotopic Thermoelectric Generators (RTGs) used in the past and currently used Multi-Mission RTGs (MMRTGs) provide power for space missions. Unfortunately, RTGs rely on thermocouples to convert heat to electricity and are inherently inefficient ({approx} 3-7% thermal to electric efficiency). A Radioisotope Thermal Photovoltaic (RTPV) power source has the potential to reduce the specific mass of the onboard power supply by increasing the efficiency of thermal to electric conversion. In an RTPV, a radioisotope heats an emitter, which emits light to a photovoltaic (PV) cell, which converts the light into electricity. Developing an emitter tuned to the desired wavelength of the photovoltaic is a key part in increasing overall performance. Researchers at the NASA Glenn Research Center (GRC) have built a Thermal Photovoltaic (TPV) system, that utilizes a simulated General Purpose Heat Source (GPHS) from a MMRTG to heat a tantalum emitter. The GPHS is a block of graphite roughly 10 cm by 10 cm by 5 cm. A fully loaded GPHS produces 250 w of thermal power and weighs 1.6 kgs. The GRC system relies on the GPHS unit radiating at 1200 K to a tantalum emitter that, in turn, radiates light to a GaInAs photo-voltaic cell. The GRC claims system efficiency of conversion of 15%. The specific mass is around 167 kg/kWe. A RTPV power source that utilized a ceramic or ceramic-metal (cermet) matrix would allow for the combination of the heat source, canister, and emitter into one compact unit, and allow variation in size

  11. The $\\alpha-\\alpha$ fishbone potential revisited

    CERN Document Server

    Day, J P; Elhanafy, M; Smith, E; Woodhouse, R; Papp, Z

    2011-01-01

    The fishbone potential of composite particles simulates the Pauli effect by nonlocal terms. We determine the $\\alpha-\\alpha$ fishbone potential by simultaneously fitting to two-$\\alpha$ resonance energies, experimental phase shifts and three-$\\alpha$ binding energies. We found that essentially a simple gaussian can provide a good description of two-$\\alpha$ and three-$\\alpha$ experimental data without invoking three-body potentials.

  12. Wavelength locking of single emitters and multi-emitter modules: simulation and experiments

    Science.gov (United States)

    Yanson, Dan; Rappaport, Noam; Peleg, Ophir; Berk, Yuri; Dahan, Nir; Klumel, Genady; Baskin, Ilya; Levy, Moshe

    2016-03-01

    Wavelength-stabilized high-brightness single emitters are commonly used in fiber-coupled laser diode modules for pumping Yb-doped lasers at 976 nm, and Nd-doped ones at 808 nm. We investigate the spectral behavior of single emitters under wavelength-selective feedback from a volume Bragg (or hologram) grating (VBG) in a multi-emitter module. By integrating a full VBG model as a multi-layer thin film structure with commercial raytracing software, we simulated wavelength locking conditions as a function of beam divergence and angular alignment tolerances. Good correlation between the simulated VBG feedback strength and experimentally measured locking ranges, in both VBG misalignment angle and laser temperature, is demonstrated. The challenges of assembling multi-emitter modules based on beam-stacked optical architectures are specifically addressed, where the wavelength locking conditions must be achieved simultaneously with high fiber coupling efficiency for each emitter in the module. It is shown that angular misorientation between fast and slow-axis collimating optics can have a dramatic effect on the spectral and power performance of the module. We report the development of our NEON-S wavelength-stabilized fiber laser pump module, which uses a VBG to provide wavelength-selective optical feedback in the collimated portion of the beam. Powered by our purpose-developed high-brightness single emitters, the module delivers 47 W output at 11 A from an 0.15 NA fiber and a 0.3 nm linewidth at 976 nm. Preliminary wavelength-locking results at 808 nm are also presented.

  13. ATLAS End Cap toroid in upstanding position

    CERN Multimedia

    2005-01-01

    End Cap toroid The ATLAS End Cap toroid weights 240-ton and is 12-m diameter high. The parts of this vacuum vessel had to be integrated and tested so that End Cap Toroid has no leaks. After that it could be cooled down to 80 K.

  14. Analyses of hydraulic performance of velocity caps

    DEFF Research Database (Denmark)

    Christensen, Erik Damgaard; Degn Eskesen, Mark Chr.; Buhrkall, Jeppe;

    2014-01-01

    The hydraulic performance of a velocity cap has been investigated. Velocity caps are often used in connection with offshore intakes. CFD (computational fluid dynamics) examined the flow through the cap openings and further down into the intake pipes. This was combined with dimension analyses...

  15. 21 CFR 888.3000 - Bone cap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cap. 888.3000 Section 888.3000 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3000 Bone cap. (a) Identification. A bone cap is a...

  16. Dynamic Modeling of an Evapotranspiration Cap

    Energy Technology Data Exchange (ETDEWEB)

    Jacob J. Jacobson; Steven Piet; Rafael Soto; Gerald Sehlke; Harold Heydt; John Visser

    2005-10-01

    The U.S. Department of Energy is scheduled to design and install hundreds of landfill caps/barriers over the next several decades and these caps will have a design life expectancy of up to 1,000 years. Other landfill caps with 30 year design lifetimes are reaching the end of their original design life; the changes to these caps need to be understood to provide a basis for lifetime extension. Defining the attributes that make a successful cap (one that isolates the waste from the environment) is crucial to these efforts. Because cap systems such as landfill caps are dynamic in nature, it is impossible to understand, monitor, and update lifetime predictions without understanding the dynamics of cap degradation, which is most often due to multiple interdependent factors rather than isolated independent events. In an attempt to understand the dynamics of cap degradation, a computer model using system dynamics is being developed to capture the complex behavior of an evapotranspiration cap. The specific objectives of this project are to capture the dynamic, nonlinear feedback loop structures underlying an evapotranspiration cap and, through computer simulation, gain a better understanding of long-term behavior, influencing factors, and, ultimately, long-term cap performance.

  17. Alpha One Foundation

    Science.gov (United States)

    ... Tested Find Support Find Doctor What Is Alpha-1? Alpha-1 Antitrypsin Deficiency (Alpha-1) is a ... results for inhaled augmentation More News Our Number One Goal: Find a cure for Alpha-1. Website ...

  18. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    Science.gov (United States)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  19. Delay modeling of bipolar ECL/EFL (Emitter-Coupled Logic/Emitter-Follower-Logic) circuits

    Science.gov (United States)

    Yang, Andrew T.

    1986-08-01

    This report deals with the development of a delay-time model for timing simulation of large circuits consisting of Bipolar ECL(Emitter-Coupled Logic) and EFL (Emitter-Follower-Logic) networks. This model can provide adequate information on the performance of the circuits with a minimum expenditure of computation time. This goal is achieved by the use of proper circuit transient models on which analytical delay expressions can be derived with accurate results. The delay-model developed in this report is general enough to handle complex digital circuits with multiple inputs or/and multiple levels. The important effects of input slew rate are also included in the model.

  20. Field emission properties of capped carbon nanotubes doped by alkali metals:a theoretical investigation

    Institute of Scientific and Technical Information of China (English)

    Jin Lei; Fu Hong-Gang; Xie Ying; Yu Hai-Tao

    2012-01-01

    The electronic structures and field emission properties of capped CNT55 systems with or without alkali metal atom adsorption were systematically investigated by density functional theory calculation.The results indicate that the adsorption of alkali metal on the center site of a CNT tip is energetically favorable.In addition,the adsorption energies increase with the introduction of the electric field.The excessive negative charges on CNT tips make electron emittance much easier and result in a decrease in work function.Furthermore,the inducing effect by positively charged alkali metal atoms can be reasonably considered as the dominant reason for the improvement in field emission properties.

  1. Traceability and the new CAP

    OpenAIRE

    Maraveyas, Napoleon N.; Doukas, Yannis El.

    2009-01-01

    The Common Agricultural Policy (CAP) was strongly criticized for the food safety crises of the 1990s which included Bovine Spongiform Encephalopathy (BSE), dioxin, foot and mouth disease and swine fever to name a few. Even though the first rules on food safety date from the very early days of the EU, a need was recognized to replace a number of these rules accumulated through the years, whose implementation was difficult to monitor, with a simpler and more comprehensive approach. The result w...

  2. Ballasted and electrically steerable carbon nanotube field emitters

    Science.gov (United States)

    Cole, M. T.; Li, C.; Qu, K.; Zhang, Y.; Wang, B.; Pribat, D.; Milne, W. I.

    2012-09-01

    Here we present our on-going efforts toward the development of stable ballasted carbon nanotube-based field emitters employing hydrothermally synthesized zinc oxide nanowires and thin film silicon-on-insulator substrates. The semiconducting channel in each controllably limits the emission current thereby preventing detrimental burn-out of individual emitters that occurs due to unavoidable statistical variability in emitter characteristics, particularly in their length. Fabrication details and emitter characterization are discussed in addition to their field emission performance. The development of a beam steerable triode electron emitter formed from hexagonal carbon nanotube arrays with central focusing nanotube electrodes, is also described. Numerical ab-initio simulations are presented to account for the empirical emission characteristics. Our engineered ballasted emitters have shown some of the lowest reported lifetime variations (sources.

  3. Correlated spontaneous emission of fluorescent emitters mediated by single plasmons

    CERN Document Server

    Bouchet, Dorian; Ithurria, Sandrine; Gulinatti, Angelo; Rech, Ivan; Carminati, Rémi; De Wilde, Yannick; Krachmalnicoff, Valentina

    2016-01-01

    Manipulating the spontaneous emission of a fluorescent emitter can be achieved by placing the emitter in a nanostructured environment. A privileged spot is occupied by plasmonic structures that provide a strong confinement of the electromagnetic field, which results in an enhancement of the emitter-environment interaction. While plasmonic nanostructures have been widely exploited to control the emission properties of single photon emitters, performing the coupling between quantum emitters with plasmons poses a huge challenge. In this Letter we report on a first crucial step towards this goal by the observation of correlated emission between a single CdSe/CdS/ZnS quantum dot exhibiting single photon statistics and a fluorescent nanobead located micrometers apart. This is accomplished by coupling both emitters to a silver nanowire. Single-plasmons are created on the latter from the quantum dot, and transfer energy to excite in turn the fluorescent nanobead.

  4. Infrared spectral normal emittance/emissivity comparison

    Science.gov (United States)

    Hanssen, L.; Wilthan, B.; Filtz, J.-R.; Hameury, J.; Girard, F.; Battuello, M.; Ishii, J.; Hollandt, J.; Monte, C.

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. Thermal emittance measurements of a cesium potassium antimonide photocathode

    OpenAIRE

    Bazarov, Ivan; Cultrera, Luca; Bartnik, Adam; Dunham, Bruce; Karkare, Siddharth; Li, Yulin; Liu, Xianghong; Maxson, Jared; Roussel, William

    2011-01-01

    Thermal emittance measurements of a CsK2Sb photocathode at several laser wavelengths are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. The thermal emittance is 0.56+/-0.03 mm-mrad/mm(rms) at 532 nm wavelength. The results are compared with a simple photoemission model and found to be in a good agreement.

  6. Thermal emittance measurements of a cesium potassium antimonide photocathode

    Science.gov (United States)

    Bazarov, Ivan; Cultrera, Luca; Bartnik, Adam; Dunham, Bruce; Karkare, Siddharth; Li, Yulin; Liu, Xianghong; Maxson, Jared; Roussel, William

    2011-05-01

    Thermal emittance measurements of a CsK2Sb photocathode at several laser wavelengths are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. The thermal emittance is 0.56±0.03 mm mrad/mm(rms) at 532 nm wavelength. The results are compared with a simple photoemission model and found to be in a good agreement.

  7. Multiple emitter location and signal parameter estimation

    Science.gov (United States)

    Schmidt, R. O.

    1986-03-01

    Multiple signal classification (MUSIC) techniques involved in determining the parameters of multiple wavefronts arriving at an antenna array are discussed. A MUSIC algorithm is described, which provides asymptotically unbiased estimates of (1) the number of signals, (2) directions of arrival (or emitter locations), (3) strengths and cross correlations among the incident waveforms, and (4) the strength of noise/interference. The example of the use of the algorithm as a multiple frequency estimator operating on time series is examined. Comparisons of this method with methods based on maximum likelihood and maximum entropy, as well as conventional beamforming, are presented.

  8. Low emittance electron beam optics commissioning in Indus-2

    International Nuclear Information System (INIS)

    Currently Indus-2 is normally operated with beam emittance of 85 nmrad at 2.0 GeV. In order to reduce the beam emittance to half of this value its dispersion function has been modified by properly choosing the quadrupoles strengths of the lattice. At this low beam emittance optics dynamic aperture reduces and may not be sufficient for beam injection thus a procedure has been evolved and implemented to shift the beam emittance of stored beam at 2.0 GeV. (author)

  9. Intelligent Variable Emittance Panels Using New, ""True"" Solid Electrolyte Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This work further developed a highly promising Variable Emittance technology for spacecraft thermal control based on Conducting Polymer (CP) electrochromics...

  10. Barium depletion in hollow cathode emitters

    Energy Technology Data Exchange (ETDEWEB)

    Polk, James E., E-mail: james.e.polk@jpl.nasa.gov; Mikellides, Ioannis G.; Katz, Ira [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109 (United States); Capece, Angela M. [Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, California 91125 (United States)

    2016-01-14

    Dispenser hollow cathodes rely on a consumable supply of Ba released by BaO-CaO-Al{sub 2}O{sub 3} source material in the pores of a tungsten matrix to maintain a low work function surface. The examination of cathode emitters from long duration tests shows deposits of tungsten at the downstream end that appear to block the flow of Ba from the interior. In addition, a numerical model of Ba transport in the cathode plasma indicates that the Ba partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant Ba-producing reaction, and it was postulated previously that this would suppress Ba loss in the upstream part of the emitter. New measurements of the Ba depletion depth from a cathode insert operated for 8200 h reveal that Ba loss is confined to a narrow region near the downstream end, confirming this hypothesis. The Ba transport model was modified to predict the depletion depth with time. A comparison of the calculated and measured depletion depths gives excellent qualitative agreement, and quantitative agreement was obtained assuming an insert temperature 70 °C lower than measured beginning-of-life values.

  11. Muon Emittance Exchange with a Potato Slicer

    Energy Technology Data Exchange (ETDEWEB)

    Summers, D. J. [Univ. of Mississippi, Oxford, MS (United States); Hart, T. L. [Univ. of Mississippi, Oxford, MS (United States); Acosta, J. G. [Univ. of Mississippi, Oxford, MS (United States); Cremaldi, L. M. [Univ. of Mississippi, Oxford, MS (United States); Oliveros, S. J. [Univ. of Mississippi, Oxford, MS (United States); Perera, L. P. [Univ. of Mississippi, Oxford, MS (United States); Neuffer, D. V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-04-15

    We propose a novel scheme for final muon ionization cooling with quadrupole doublets followed by emittance exchange in vacuum to achieve the small beam sizes needed by a muon collider. A flat muon beam with a series of quadrupole doublet half cells appears to provide the strong focusing required for final cooling. Each quadrupole doublet has a low beta region occupied by a dense, low Z absorber. After final cooling, normalized transverse, longitudinal, and angular momentum emittances of 0.100, 2.5, and 0.200 mm-rad are exchanged into 0.025, 70, and 0.0 mm-rad. A skew quadrupole triplet transforms a round muon bunch with modest angular momentum into a flat bunch with no angular momentum. Thin electrostatic septa efficiently slice the flat bunch into 17 parts. The 17 bunches are interleaved into a 3.7 meter long train with RF deflector cavities. Snap bunch coalescence combines the muon bunch train longitudinally in a 21 GeV ring in 55 µs, one quarter of a synchrotron oscillation period. A linear long wavelength RF bucket gives each bunch a different energy causing the bunches to drift in the ring until they merge into one bunch and can be captured in a short wavelength RF bucket with a 13% muon decay loss and a packing fraction as high as 87 %.

  12. Narrowband infrared emitters for combat ID

    Science.gov (United States)

    Pralle, Martin U.; Puscasu, Irina; Daly, James; Fallon, Keith; Loges, Peter; Greenwald, Anton; Johnson, Edward

    2007-04-01

    There is a strong desire to create narrowband infrared light sources as personnel beacons for application in infrared Identify Friend or Foe (IFF) systems. This demand has augmented dramatically in recent years with the reports of friendly fire casualties in Afghanistan and Iraq. ICx Photonics' photonic crystal enhanced TM (PCE TM) infrared emitter technology affords the possibility of creating narrowband IR light sources tuned to specific IR wavebands (near 1-2 microns, mid 3-5 microns, and long 8-12 microns) making it the ideal solution for infrared IFF. This technology is based on a metal coated 2D photonic crystal of air holes in a silicon substrate. Upon thermal excitation the photonic crystal modifies the emitted yielding narrowband IR light with center wavelength commensurate with the periodicity of the lattice. We have integrated this technology with microhotplate MEMS devices to yield 15mW IR light sources in the 3-5 micron waveband with wall plug efficiencies in excess of 10%, 2 orders of magnitude more efficient that conventional IR LEDs. We have further extended this technology into the LWIR with a light source that produces 9 mW of 8-12 micron light at an efficiency of 8%. Viewing distances >500 meters were observed with fielded camera technologies, ideal for ground to ground troop identification. When grouped into an emitter panel, the viewing distances were extended to 5 miles, ideal for ground to air identification.

  13. Muon Emittance Exchange with a Potato Slicer

    CERN Document Server

    Summers, D J; Acosta, J G; Cremaldi, L M; Oliveros, S J; Perera, L P; Neuffer, D V

    2015-01-01

    We propose a novel scheme for final muon ionization cooling with quadrupole doublets followed by emittance exchange in vacuum to achieve the small beam sizes needed by a muon collider. A flat muon beam with a series of quadrupole doublet half cells appears to provide the strong focusing required for final cooling. Each quadrupole doublet has a low beta region occupied by a dense, low Z absorber. After final cooling, normalized transverse, longitudinal, and angular momentum emittances of 0.100, 2.5, and 0.200 mm-rad are exchanged into 0.025, 70, and 0.0 mm-rad. A skew quadrupole triplet transforms a round muon bunch with modest angular momentum into a flat bunch with no angular momentum. Thin electrostatic septa efficiently slice the flat bunch into 17 parts. The 17 bunches are interleaved into a 3.7 meter long train with RF deflector cavities. Snap bunch coalescence combines the muon bunch train longitudinally in a 21 GeV ring in 55 microseconds, one quarter of a synchrotron oscillation period. A linear long ...

  14. Minimizing Emittance for the CLIC Damping Ring

    CERN Document Server

    Braun, H; Levitchev, E; Piminov, P; Schulte, Daniel; Siniatkin, S; Vobly, P P; Zimmermann, Frank; Zolotarev, Konstantin V; CERN. Geneva

    2006-01-01

    The CLIC damping rings aim at unprecedented small normalized equilibrium emittances of 3.3 nm vertical and 550 nm horizontal, for a bunch charge of 2.6·109 particles and an energy of 2.4 GeV. In this parameter regime the dominant emittance growth mechanism is intra-beam scattering. Intense synchrotron radiation damping from wigglers is required to counteract its effect. Here the overall optimization of the wiggler parameters is described, taking into account state-of-the-art wiggler technologies, wiggler effects on dynamic aperture, and problems of wiggler radiation absorption. Two technical solutions, one based on superconducting magnet technology the other on permanent magnets are presented. Although dynamic aperture and tolerances of this ring design remain challenging, benefits are obtained from the strong damping. For optimized wigglers, only bunches for a single machine pulse may need to be stored, making injection/extraction particularly simple and limiting the synchrotron-radiation power. With a 36...

  15. Barium depletion in hollow cathode emitters

    International Nuclear Information System (INIS)

    Dispenser hollow cathodes rely on a consumable supply of Ba released by BaO-CaO-Al2O3 source material in the pores of a tungsten matrix to maintain a low work function surface. The examination of cathode emitters from long duration tests shows deposits of tungsten at the downstream end that appear to block the flow of Ba from the interior. In addition, a numerical model of Ba transport in the cathode plasma indicates that the Ba partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant Ba-producing reaction, and it was postulated previously that this would suppress Ba loss in the upstream part of the emitter. New measurements of the Ba depletion depth from a cathode insert operated for 8200 h reveal that Ba loss is confined to a narrow region near the downstream end, confirming this hypothesis. The Ba transport model was modified to predict the depletion depth with time. A comparison of the calculated and measured depletion depths gives excellent qualitative agreement, and quantitative agreement was obtained assuming an insert temperature 70 °C lower than measured beginning-of-life values

  16. Compact Rare Earth Emitter Hollow Cathode

    Science.gov (United States)

    Watkins, Ronald; Goebel, Dan; Hofer, Richard

    2010-01-01

    A compact, high-current, hollow cathode utilizing a lanthanum hexaboride (LaB6) thermionic electron emitter has been developed for use with high-power Hall thrusters and ion thrusters. LaB6 cathodes are being investigated due to their long life, high current capabilities, and less stringent xenon purity and handling requirements compared to conventional barium oxide (BaO) dispenser cathodes. The new cathode features a much smaller diameter than previously developed versions that permit it to be mounted on axis of a Hall thruster ( internally mounted ), as opposed to the conventional side-mount position external to the outer magnetic circuit ("externally mounted"). The cathode has also been reconfigured to be capable of surviving vibrational loads during launch and is designed to solve the significant heater and materials compatibility problems associated with the use of this emitter material. This has been accomplished in a compact design with the capability of high-emission current (10 to 60 A). The compact, high-current design has a keeper diameter that allows the cathode to be mounted on the centerline of a 6- kW Hall thruster, inside the iron core of the inner electromagnetic coil. Although designed for electric propulsion thrusters in spacecraft station- keeping, orbit transfer, and interplanetary applications, the LaB6 cathodes are applicable to the plasma processing industry in applications such as optical coatings and semiconductor processing where reactive gases are used. Where current electrical propulsion thrusters with BaO emitters have limited life and need extremely clean propellant feed systems at a significant cost, these LaB6 cathodes can run on the crudest-grade xenon propellant available without impact. Moreover, in a laboratory environment, LaB6 cathodes reduce testing costs because they do not require extended conditioning periods under hard vacuum. Alternative rare earth emitters, such as cerium hexaboride (CeB6) can be used in this

  17. An H-alpha search for over-dense regions at z=2.23

    CERN Document Server

    Matsuda, Y; Geach, J E; Best, P N; Sobral, D; Tanaka, I; Ohta, K; Kurk, J; Iwata, I; Bielby, Rich; Wardlow, J L; Bower, R G; Fanidakis, N; Ivison, R J; Kodama, T; Yamada, T; Mawatari, K; Casali, M

    2011-01-01

    We present the results of a narrow-band (H2S1, 2.121/0.021um) imaging search with WFCAM/UKIRT for H-alpha emitters around several potential signposts of rare (10^-7-10^-8 Mpc^-3) over-dense regions at z=2.23: an over-density of QSOs (2QZ cluster), a powerful, high-redshift radio galaxy (HzRG), and a concentration of submillimetre galaxies (SMGs) and optically faint radio galaxies (OFRGs). In total, we detect 137 narrow-band emitter candidates down to emission-line fluxes of 0.5-1 x 10^-16 erg s^-1 cm^-2, across a total area of 0.56 sq. degrees (2.1 x 10^5 comoving Mpc at z=2.23) in these fields. The BzK colours of the emitters suggest that at least 80% of our sample are likely to be H-alpha emitters (HAEs) at z=2.23. This is one of the largest HAE samples known at z>2. We find modest (~3-sigma) local over-densities of emitters associated with all the three targets. In the 2QZ cluster field, the emitters show a striking filamentary structure connecting four of the z=2.23 QSOs extending over 30Mpc (comoving). I...

  18. Jamming of Quantum Emitters by Active Coated Nanoparticles

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Ziolkowski, Richard W.

    2013-01-01

    effectively cloak the emitters to a far-field observer is reported and explained through thorough near- and far-field investigations. This property offers an interesting route toward the jamming of quantum emitters/nanoantennas that might be of potential use, for instance, in biological fluorescence assays...

  19. Emitter space charge layer transit time in bipolar junction transistors

    Science.gov (United States)

    Rustagi, S. C.; Chattopadhyaya, S. K.

    1981-04-01

    The charge defined emitter space charge layer transit times of double diffused transistors have been calculated using a regional approach, and compared with the corresponding base transit times. The results obtained for emitter space-charge layer transit times have been discussed with reference to the capacitance analysis of Morgan and Smit (1960) for graded p-n junctions.

  20. Spectral beam combining of multi-single emitters

    Science.gov (United States)

    Wang, Baohua; Guo, Weirong; Guo, Zhijie; Xu, Dan; Zhu, Jing; Zhang, Qiang; Yang, Thomas; Chen, Xiaohua

    2016-03-01

    Spectral beam combination expands the output power while keeps the beam quality of the combined beam almost the same as that of a single emitter. Spectral beam combination has been successfully achieved for high power fiber lasers, diode laser arrays and diode laser stacks. We have recently achieved the spectral beam combination of multiple single emitter diode lasers. Spatial beam combination and beam transformation are employed before beams from 25 single emitter diode lasers can be spectrally combined. An average output power about 220W, a spectral bandwidth less than 9 nm (95% energy), a beam quality similar to that of a single emitter and electro-optical conversion efficiency over 46% are achieved. In this paper, Rigorous Coupled Wave analysis is used to numerically evaluate the influence of emitter width, emitter pitch and focal length of transform lens on diffraction efficiency of the grating and spectral bandwidth. To assess the chance of catastrophic optical mirror damage (COMD), the optical power in the internal cavity of a free running emitter and the optical power in the grating external cavity of a wavelength locked emitter are theoretically analyzed. Advantages and disadvantages of spectral beam combination are concluded.

  1. Emittance measurements of low-energy beam line at KVI

    NARCIS (Netherlands)

    Toprek, D; Formanoy, [No Value

    2006-01-01

    In this paper is represented the results of beam profile measurements of He-3(+) beam delivered from ECR ion source at KVI. The beam emittance is estimated by varying quadrupole method. The estimated values for the beam emittance at the different profile grid locations along the transport beam line

  2. Coated nano-particle jamming of quantum emitters

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Ziolkowski, Richard W.

    2012-01-01

    Spherical active coated nano-particles are examined analytically and numerically in the presence of one, two or four quantum emitters (electric Hertzian dipoles). The ability of the coated nano-particle to effectively cloak the emitters to a far-field observer is reported. This offers an...

  3. Properties of nanolasers based on few discrete emitters

    DEFF Research Database (Denmark)

    Lund, Anders Mølbjerg; Nielsen, Per Kær; Lorke, Michael;

    2012-01-01

    emitters and 100 photon states the density matrix has more than 2.5 × 106 elements. We have been able to simplify the problem significantly by adiabatically eliminating the photon-assisted polarizations and the correlations between emitters and cavity [3]. This results in a set of rate equations...

  4. Bunch transverse emittance increase in electron storage rings

    Institute of Scientific and Technical Information of China (English)

    GAO Jie

    2009-01-01

    In this paper a theoretical framework to estimate the bunch transverse emittance growing in electron storage rings due to short range transverse wakefield of the machine is established. New equilibrium emittance equations are derived and applied to explain the experimentally obtained results in ATF damping ring. This equation will be useful for linear collider damping ring design.

  5. Vertically integrated (Ga, In)N nanostructures for future single photon emitters operating in the telecommunication wavelength range.

    Science.gov (United States)

    Winden, A; Mikulics, M; Grützmacher, D; Hardtdegen, H

    2013-10-11

    Important technological steps are discussed and realized for future room-temperature operation of III-nitride single photon emitters. First, the growth technology of positioned single pyramidal InN nanostructures capped by Mg-doped GaN is presented. The optimization of their optical characteristics towards narrowband emission in the telecommunication wavelength range is demonstrated. In addition, a device concept and technology was developed so that the nanostructures became singularly addressable. It was found that the nanopyramids emit in the telecommunication wavelength range if their size is chosen appropriately. A p-GaN contacting layer was successfully produced as a cap to the InN pyramids and the top p-contact was achievable using an intrinsically conductive polymer PEDOT:PSS, allowing a 25% increase in light transmittance compared to standard Ni/Au contact technology. Single nanopyramids were successfully integrated into a high-frequency device layout. These decisive technology steps provide a promising route to electrically driven and room-temperature operating InN based single photon emitters in the telecommunication wavelength range.

  6. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  7. Emittance Measurements for Beams Extracted from LECR3 Ion Source

    Institute of Scientific and Technical Information of China (English)

    CaoYun; ZhaoHongwei; MaLei; ZhangZimin

    2003-01-01

    High quality ion beams are required by IMP cyclotron and atomic physics research, so it is important to research and measure beam emitt ance of ECR ion source. Intense beams extracted from ECR ion source usually have low energy, so it is suitable to use Electric-Sweep Scanner to measure the emittance. This kind of measurement is popularly used at ECR ion source, and it has some prominent merits such as high accuracy, very short time of data processing and easy expressing of the emittance pattern. So we designed and built this emittance scanner to measure emittance of the ion beams produced by LECR3 ion source. The structure of the ESS is shown in Fig.l, and the photo of the ESS is shown in Fig.2.

  8. Superradiance of a subwavelength array of independent classical nonlinear emitters

    CERN Document Server

    Nefedkin, N E; Zyablovsky, A A; Pukhov, A A; Vinogradov, A P; Lisyansky, A A

    2015-01-01

    We suggest a mechanism for the emergence of a superradiance burst in a subwavelength array of nonlinear classical emitters. We assume that the emitters interact via their common field of radiative response and that they may have an arbitrary distribution of initially phases. We show that only if this distribution is not uniform, a non-zero field of radiative response arises leading to a superradiance burst. Although this field cannot synchronize the emitters, it forces fast oscillations of a classical nonlinear emitter to have long-period envelopes. Constructive interference in the envelopes creates a large dipole moment of the array which results in a superradiance pulse. The intensity of the superradiance is proportional to the squared number of the emitters, which envelopes participate in the fluctuation.

  9. Self-consistent, unbiased root-mean-square emittance analysis

    Science.gov (United States)

    Stockli, Martin P.; Welton, R. F.; Keller, R.

    2004-05-01

    We present a self-consistent method for analyzing measured emittance data that yields unbiased estimates for the root-mean-square (rms) emittance. The self-consistent, unbiased elliptical exclusion analysis uses an ellipse to determine the bias from the data outside the ellipse, before calculating the rms emittance from the bias-subtracted data within the ellipse. Increasing the ellipse size until the rms emittance estimate saturates allows for determining the minimum elliptical area that includes all real signals, even those buried in the noise. Variations of the ellipse shape and orientations are used to test the robustness of the results. Background fluctuations cause fluctuations in the rms emittance estimate, which are an estimate of the uncertainty incurred through the analysis.

  10. Satellite altimeter remote sensing of ice caps

    OpenAIRE

    Rinne, Eero Juhani

    2011-01-01

    This thesis investigates the use of satellite altimetry techniques for measuring surface elevation changes of ice caps. Two satellite altimeters, Radar Altimeter 2 (RA-2) and Geoscience Laser Altimeter System (GLAS) are used to assess the surface elevation changes of three Arctic ice caps. This is the first time the RA-2 has been used to assess the elevation changes of ice caps - targets much smaller than the ice sheets which are the instrument’s primary land ice targets. Algor...

  11. Emittance compensation for an SRF photo injector

    Energy Technology Data Exchange (ETDEWEB)

    Vennekate, H.; Lu, P. [HZDR (Germany); TU Dresden (Germany); Arnold, A.; Mucek, P.; Teichert, J.; Xiang, R. [HZDR (Germany); Kamps, T. [HZB (Germany); Kneisel, P. [JLab (Germany); Voelker, J. [HZB (Germany); Humboldt Universitaet Berlin (Germany); Volkov, V. [BINP (Germany); Will, I. [MBI (Germany)

    2013-07-01

    The development of a superconducting photo injector is an ongoing challenge at the HZDR in Dresden. Several milestones like the first operation of a half cell niobium cavity in 2002 and the worldwide first beam transfer from a 3 1/2-cell SRF gun into an actual accelerator structure have already been accomplished. Nevertheless, as superconducting electron sources are of great interest for future ERL or cw operated FEL projects, studies to improve their output parameters and stability continue to get them on the same level as their normal conducting counterparts. The talk discusses several of the current approaches to reduce the transversal emittance of the next 3 1/2-cell cavity at the HZDR including the installation of a superconducting solenoid within the gun's cryostat.

  12. Gamma emitters in Hong Kong water

    International Nuclear Information System (INIS)

    Radioactivity in water originates from natural and artificial sources. The development of a nuclear powerplant near Hong Kong necessitates that attention be given to formulating techniques to assess the possible resultant environmental radioactive contamination. Water samples collected from various sites in Hong Kong in the spring and summer of 1987, representing seawater, river water, reservoir water, drinking water, and underground water were studied through gamma-ray spectral analysis. Only gamma emitters in the U238 and Th232 series and K40 were detected. No fission product was detected with specific activity above 0.1 Bq/kg. The data could be the baseline for future monitoring of the radioactivity released from a nuclear plant being built at a 50-km distance from Hong Kong. The variation of detected specific activities may be due to geological differences and the effect of plants. 1 ref., 3 tabs

  13. Space Charge Effects in Rectilinear Motion Emittance

    CERN Document Server

    Chen, C

    2000-01-01

    This report summarizes the presentations and discussions over a wide range of topics in Working Group I at the Second ICFA Advanced Accelerator Workshop on Physics of High-Brightness Beams held at University of California at Los $9 Angeles (UCLA), November 9-12, 1999. Latest developments towards to a better understanding of high-brightness photoinjectors were reported. The design and commissioning of the Los Alamos National Laboratory (LANL) Low-Energy $9 Demonstration Accelerator (LEDA) Radio-Frequency Quadrupole (RFQ) were reported. The problem of beam halo formation was discussed in both beam transport systems and the SLAC 50 MW 11.4 GHz periodic permanent magnet (PPM) focusing $9 klystron amplifier. A new class of corkscrewing elliptic beam equilibria was reported, and applications of such novel beam equilibria in controlling of charge-density and velocity fluctuations, beam halo formation and emittance $9 growth were discussed. Pattern formation in proton rings was also discussed.

  14. Gross alpha radioactivity of drinking water in Venezuela

    International Nuclear Information System (INIS)

    Bottled mineral water is consumed by a large population in Venezuela. The alpha emitters concentration was measured in samples of bottled water and water springs collected near the surface. Approximately 30% of the total mineral water suppliers was monitored. a database on natural and artificial radioactivity in drinking water was produced. Results indicate that 54% of the waters sampled contain a total alpha radioactivity of less than 0.185 Bql-1 and only 12% above 0.37 Bql-1. Our results revealed a total annual dose of 2.3 mSv year-1. (author)

  15. The Ly$\\alpha$ emission from high-$z$ galaxies hosting strong Damped Ly$\\alpha$ systems

    CERN Document Server

    Joshi, Ravi; Noterdaeme, Pasquier; Petitjean, Patrick

    2016-01-01

    We study the average Ly$\\alpha$ emission associated with high-$z$ strong (log $N$(H I) $\\ge$ 21) damped Ly$\\alpha$ systems (DLAs). We report Ly$\\alpha$ luminosities ($L_{\\rm Ly\\alpha}$) for the full as well as various sub-samples based on $N$(H I), $z$, $(r-i)$ colours of QSOs and rest equivalent width of Si II$\\lambda$1526 line (i.e., $W_{1526}$). For the full sample, we find $L_{\\rm Ly\\alpha}$$< 10^{41} (3\\sigma)\\ \\rm erg\\ s^{-1}$ with a $2.8\\sigma$ level detection of Ly$\\alpha$ emission in the red part of the DLA trough. The $L_{\\rm Ly\\alpha}$ is found to be higher for systems with higher $W_{1526}$ with its peak, detected at $\\geq 3\\sigma$, redshifted by about 300-400 $\\rm km\\ s^{-1}$ with respect to the systemic absorption redshift, as seen in Lyman Break Galaxies (LBGs) and Ly$\\alpha$ emitters. A clear signature of a double-hump Ly$\\alpha$ profile is seen when we consider $W_{1526} \\ge 0.4$ \\AA\\ and $(r-i) < 0.05$. Based on the known correlation between metallicity and $W_{1526}$, we interpret our...

  16. Physical electrostatics of small field emitter arrays/clusters

    Science.gov (United States)

    Forbes, Richard G.

    2016-08-01

    This paper aims to improve qualitative understanding of electrostatic influences on apex field enhancement factors (AFEFs) for small field emitter arrays/clusters. Using the "floating sphere at emitter-plate potential" (FSEPP) model, it re-examines the electrostatics and mathematics of three simple systems of identical post-like emitters. For the isolated emitter, various approaches are noted. An adequate approximation is to consider only the effects of sphere charges and (for significantly separated emitters) image charges. For the 2-emitter system, formulas are found for charge-transfer ("charge-blunting") effects and neighbor-field effects, for widely spaced and for "sufficiently closely spaced" emitters. Mutual charge-blunting is always the dominant effect, with a related (negative) fractional AFEF-change δtwo. For sufficiently small emitter spacing c, |δtwo| varies approximately as 1/c; for large spacing, |δtwo| decreases as 1/c3. In a 3-emitter equispaced linear array, differential charge-blunting and differential neighbor-field effects occur, but differential charge-blunting effects are dominant, and cause the "exposed" outer emitters to have higher AFEF (γ0) than the central emitter (γ1). Formulas are found for the exposure ratio Ξ = γ0/γ1, for large and for sufficiently small separations. The FSEPP model for an isolated emitter has accuracy around 30%. Line-charge models (LCMs) are an alternative, but an apparent difficulty with recent LCM implementations is identified. Better descriptions of array electrostatics may involve developing good fitting equations for AFEFs derived from accurate numerical solution of Laplace's equation, perhaps with equation form(s) guided qualitatively by FSEPP-model results. In existing fitting formulas, the AFEF-reduction decreases exponentially as c increases, which is different from the FSEPP-model formulas. This discrepancy needs to be investigated, using systematic Laplace-based simulations and appropriate results

  17. Effect of thin emitter set-back layer on GaAs delta-doped emitter bipolar junction transistor

    Science.gov (United States)

    Lew, K. L.; Yoon, S. F.

    2005-05-01

    GaAs delta-doped emitter bipolar junction transistors (δ-BJT) with different emitter set-back layer thicknesses of 10to50nm were fabricated to study the emitter set-back layer thickness effect on device dc performance. We found that the current gain decreases following decrease in the emitter set-back layer thickness. A detailed analysis was performed to explain this phenomenon, which is believed to be caused by reduction of the effective barrier height in the δ-BJT. This is due to change in the electric-field distribution in the delta-doped structure caused by the built-in potential of the base-emitter (B-E ) junction. Considering the recombination and barrier height reduction effects, the thickness of the emitter set-back layer should be designed according to the B-E junction depletion width with a tolerance of ±5nm. The dc performance of a δ-BJT designed based on this criteria is compared to that of a Al0.25Ga0.75As /GaAs heterojunction bipolar transistor (HBT). Both devices employed base doping of 2×1019cm-3 and base-to-emitter doping ratio of 40. Large emitter area (AE≈1.6×10-5cm-2) and small emitter area (AE≈1.35×10-6cm-2) device current gains of 40 and 20, respectively, were obtained in both types of transistors passivated by (NH4)2S treatment. The measured current gain of the GaAs δ-BJT is the highest reported for a homojunction device with such high base-to-emitter doping ratio normally used in HBT devices.

  18. Synthesis, Characterization, and Tribological Behavior of Oleic Acid Capped Graphene Oxide

    Directory of Open Access Journals (Sweden)

    Tiedan Chen

    2014-01-01

    Full Text Available Graphene oxide (GO nanosheets were prepared by modified Hummers and Offeman methods. Furthermore, oleic acid (OA capped graphene oxide (OACGO nanosheets were prepared and characterized by means of Fourier transform-infrared spectroscopy (FT-IR, transmission electron microscopy (TEM, and X-ray diffraction (XRD. At the same time, the friction and wear properties of OA capped graphite powder (OACG, OACGO, and oleic acid capped precipitate of graphite (OACPG as additives in poly-alpha-olefin (PAO were compared using four-ball tester and SRV-1 reciprocating ball-on-disc friction and wear tester. By the addition of OACGO to PAO, the antiwear ability was improved and the friction coefficient was decreased. Also, the tribological mechanism of the GO was investigated.

  19. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  20. Gross alpha determination in radioactive wastes from nuclear power plants using the track registration technique

    Energy Technology Data Exchange (ETDEWEB)

    Suarez-Navarro, M.J. [Universidad Politecnica de Madrid (UPM) E.T.S.I de Caminos, Canales y Puertos, Profesor Aranguren, s/n, 28040 Madrid (Spain)]. E-mail: he04@caminos.upm.es; Pujol, Ll. [Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), Alfonso XII, 3, 28014 Madrid (Spain); Gonzalez-Gonzalez, J.A. [Universidad Politecnica de Madrid (UPM) E.T.S.I de Caminos, Canales y Puertos, Profesor Aranguren, s/n, 28040 Madrid (Spain)

    2007-03-15

    Low and intermediate level nuclear wastes (ion-exchange resins and evaporator concentrates) essentially contain beta and gamma emitters, with very few alpha emitters. Several techniques may be used to determine gross alpha activity but, in this case, solid-state nuclear track detectors (SSNTDs) are a suitable technique for gross alpha determination because track detectors are not sensitive to beta and gamma emitters. Also, this technique is simple and inexpensive. In this paper, we studied the parameters (background, efficiency and self-absorption) that could affect the gross alpha determination using SSNTDs for both sample preparation methods, the 'dry method' with tensioactives and the 'wet method'. For the 'dry method', a self-absorption curve for {sup 241}Am standard was prepared using a set of varying thickness of sodium salt and for two different tensioactives: Tween{sup (R)}20 and Teg. The results showed that, below 1mg/cm{sup 2}, the self-absorption factor can be considered similar for both tensioactives and equal to unity. Several detectors for gross alpha determination were compared and we found that the most suitable techniques were ZnS(Ag) solid scintillator and track detectors. Both detectors were used to compare radioactive waste samples. Finally, the proposed methods ('dry method' with Teg tensioactive and 'wet method') using track detectors were tested by analysing the gross alpha activity of several radioactive wastes.

  1. Courant-Snyder invariant density screening method for emittance analysis

    Institute of Scientific and Technical Information of China (English)

    SUN Ji-Lei; TANG Jing-Yu; JING Han-Tao

    2011-01-01

    Emittance is an important characteristic of describing charged particle beams.In hadron accelerators,we often meet irregular beam distributions that are not appropriately described by a single rms emittance or 95% emittance or total emittance.In this paper,it is pointed out that in many cases a beam halo should be described with very different Courant-Snyder parameters from the ones used for the beam core.A new method - the Courant-Snyder invariant density screening method - is introduced for analyzing emittance data clearly and accurately.The method treats the emittance data from both measurements and numerical simulations.The method uses the statistical distribution of the beam around each particle in phase space to mark its local density parameter,and then uses the density distribution to calculate the beam parameters such as the Courant-Snyder parameters and emittance for different beam boundary definitions.The method has been used in the calculations for.beams from different sources,and shows its advantages over other methods.An application code based on the method including the graphic interface has also been designed.

  2. Low-emittance tuning at the Cornell Electron Storage Ring

    CERN Document Server

    Shanks, James; Sagan, David

    2013-01-01

    In 2008 the Cornell Electron/Positron Storage Ring (CESR) was reconfigured from an electron/positron collider to serve as a testbed for the International Linear Collider (ILC) damping rings. One of the primary goals of the CESR Test Accelerator (CesrTA) project is to develop low emittance tuning techniques to achieve sub-10pm geometric vertical emittance at 2.085 GeV. This paper discusses the tuning methods used at CesrTA to achieve low-emittance conditions. A minimum vertical emittance of 8.7 +2.9/-3.4(sys) +/-0.2(stat) pm has been achieved at 2.085 GeV. In various configurations and beam energies the correction technique routinely achieves vertical emittance <15 pm after correction. Beam-based measurement and correction requires about 15 minutes. Simulations modeling the effects of magnet misalignments, BPM errors, and emittance correction algorithm suggest the residual vertical emittance measured at the conclusion of the tuning procedure is dominated by sources other than optics errors and misalignments...

  3. Nature mangement, landscape and the CAP

    NARCIS (Netherlands)

    Brouwer, F.M.; Godeschalk, F.E.

    2004-01-01

    The integration of nature management, landscape and environmental concerns into the Common Agricultural Policy (CAP) has gained momentum with the CAP reforms adopted in June 2003. The report explores instruments and approaches that contribute to the inte-gration of nature conservation and landscape

  4. Microtubule dynamics: Caps, catastrophes, and coupled hydrolysis

    DEFF Research Database (Denmark)

    Flyvbjerg, H.; Holy, T.E.; Leibler, S.

    1996-01-01

    An effective theory is formulated for the dynamics of the guanosine triphosphate (GTP) cap believed to stabilize growing microtubules. The theory provides a ''coarse-grained'' description of the cap's dynamics. ''Microscopic'' details, such as the microtubule lattice structure and the fate of its...... data. A constant nonzero catastrophe rare, identical for both microtubule ends, is predicted at large growth rates. The delay time for dilution-induced catastrophes is stochastic with a simple distribution that fits the experimental one and, like the experimental one, does not depend on the rate of....... A recent experimental result for the size of the minimal cap that can stabilize a microtubule is shown to agree with the result predicted by the cap model, after its parameters have been extracted from previous experimental results. Thus the effective theory and cap model presented here provide a...

  5. Direct Observation of Ultralow Vertical Emittance using a Vertical Undulator

    Energy Technology Data Exchange (ETDEWEB)

    Wootton, Kent

    2015-09-17

    In recent work, the first quantitative measurements of electron beam vertical emittance using a vertical undulator were presented, with particular emphasis given to ultralow vertical emittances [K. P. Wootton, et al., Phys. Rev. ST Accel. Beams, 17, 112802 (2014)]. Using this apparatus, a geometric vertical emittance of 0.9 ± 0.3 pm rad has been observed. A critical analysis is given of measurement approaches that were attempted, with particular emphasis on systematic and statistical uncertainties. The method used is explained, compared to other techniques and the applicability of these results to other scenarios discussed.

  6. Scaled, circular-emitter Penning SPS for intense H- beams

    International Nuclear Information System (INIS)

    The Los Alamos versions of the Penning Surface-Plasma Source (SPS) routinely generate H- ion beams with pulsed currents over 100 mA. However, these sources employ geometries that result in the extraction of slit beams (0.5 x 10 mm2). Our modeling with the SNOW code indicates that the beam from a 5.4-mm-diam circular emitter will have lower emittance and divergence for transport to and injection into our radio-frequency quadrupole (RFQ) accelerator. This paper describes a newly constructed Penning SPS that has most of its discharge chamber dimensions scaled up by a factor of 4 to accommodate this circular emitter

  7. Method and apparatus for multispray emitter for mass spectrometry

    Science.gov (United States)

    Smith, Richard D.; Tang, Keqi; Lin, Yuehe

    2004-12-14

    A method and apparatus that utilizes two or more emitters simultaneously to form an electrospray of a sample that is then directed into a mass spectrometer, thereby increasing the total ion current introduced into an electrospray ionization mass spectrometer, given a liquid flow rate of a sample. The method and apparatus are most conveniently constructed as an array of spray emitters fabricated on a single chip, however, the present invention encompasses any apparatus wherein two or more emitters are simultaneously utilized to form an electrospray of a sample that is then directed into a mass spectrometer.

  8. Improved Rare-Earth Emitter Hollow Cathode

    Science.gov (United States)

    Goebel, Dan M.

    2011-01-01

    An improvement has been made to the design of the hollow cathode geometry that was created for the rare-earth electron emitter described in Compact Rare Earth Emitter Hollow Cathode (NPO-44923), NASA Tech Briefs, Vol. 34, No. 3 (March 2010), p. 52. The original interior assembly was made entirely of graphite in order to be compatible with the LaB6 material, which cannot be touched by metals during operation due to boron diffusion causing embrittlement issues in high-temperature refractory materials. Also, the graphite tube was difficult to machine and was subject to vibration-induced fracturing. This innovation replaces the graphite tube with one made out of refractory metal that is relatively easy to manufacture. The cathode support tube is made of molybdenum or molybdenum-rhenium. This material is easily gun-bored to near the tolerances required, and finish machined with steps at each end that capture the orifice plate and the mounting flange. This provides the manufacturability and robustness needed for flight applications, and eliminates the need for expensive e-beam welding used in prior cathodes. The LaB6 insert is protected from direct contact with the refractory metal tube by thin, graphite sleeves in a cup-arrangement around the ends of the insert. The sleeves, insert, and orifice plate are held in place by a ceramic spacer and tungsten spring inserted inside the tube. To heat the cathode, an insulating tube is slipped around the refractory metal hollow tube, which can be made of high-temperature materials like boron nitride or aluminum nitride. A screw-shaped slot, or series of slots, is machined in the outside of the ceramic tube to constrain a refractory metal wire wound inside the slot that is used as the heater. The screw slot can hold a single heater wire that is then connected to the front of the cathode tube by tack-welding to complete the electrical circuit, or it can be a double slot that takes a bifilar wound heater with both leads coming out

  9. Molecular breast imaging with gamma emitters.

    Science.gov (United States)

    Schillaci, O; Spanu, A; Danieli, R; Madeddu, G

    2013-12-01

    Following a diagnosis of breast cancer (BC), the early detection of local recurrence is important to define appropriate therapeutic strategies and increase the chances of a cure. In fact, despite major progress in surgical treatment, radiotherapy, and chemotherapy protocols, tumor recurrence is still a major problem. Moreover, the diagnosis of recurrence with conventional imaging methods can be difficult as a result of the presence of scar tissue. Molecular breast imaging (MBI) with gamma-ray emitting radiotracers may be very useful in this clinical setting, because it is not affected by the post-therapy morphologic changes. This review summarises the applications of 99mTc-sestamibi and 99mTc-tetrofosmin, the two most employed gamma emitter radiopharmaceuticals for MBI, in the diagnosis of local disease recurrence in patients with BC. The main limitation of MBI using conventional gamma-cameras is the low sensitivity for small BCs. The recent development of hybrid single photon emission computed tomography/computed tomography devices and especially of high-resolution specific breast cameras can improve the detection rate of sub-centimetric malignant lesions. Nevertheless, probably only the large availability of dedicated cameras will allow the clinical acceptance of MBI as useful complementary diagnostic technique in BC recurrence. The possible role of MBI with specific cameras in monitoring the local response of BC to neoadjuvant chemotherapy is also briefly discussed. PMID:24322791

  10. Novalike Cataclysmic Variables are Significant Radio Emitters

    CERN Document Server

    Coppejans, Deanne L; Miller-Jones, James C A; Rupen, Michael P; Knigge, Christian; Sivakoff, Gregory R; Groot, Paul J

    2015-01-01

    Radio emission from non-magnetic cataclysmic variables (CVs, accreting white dwarfs) could allow detailed studies of outflows and possibly accretion flows in these nearby, numerous and non-relativistic compact accretors. Up to now, however, very few CVs have been detected in the radio. We have conducted a VLA pilot survey of four close and optically-bright novalike CVs at 6 GHz, detecting three, and thereby doubling the number of radio detections of these systems. RW Sex, V603 Aql and the old nova TT Ari were detected in both of the epochs, while V1084 Her was not detected (to a $3\\sigma$ upper-limit of 7.8 $\\mu\\rm{Jy}\\,\\rm{beam}^{-1}$). These observations clearly show that the sensitivity of previous surveys was typically too low to detect these objects and that non-magnetic CVs can indeed be significant radio emitters. The three detected sources show a range of properties, including flaring and variability on both short ($\\sim$200 s) and longer-term (days) time-scales, as well as circular polarization level...

  11. Fabrication of arrayed glassy carbon field emitters

    Energy Technology Data Exchange (ETDEWEB)

    Sohda, Y.; Tanenbaum, D.M.; Turner, S.W.; Craighead, H.G. [School of Engineering and Applied Physics, Cornell University, Ithaca, New York 14853 (United States)

    1997-03-01

    Glassy carbon has desirable properties for electron field emission such as surface inertness, electrical conductivity, and thermal stability. In addition, a uniform thick substrate with a polished surface is easily obtainable. This enables one to apply large scale integrated circuit processing for fabricating arrayed tips. By using oxygen reactive ion etching, cusps over 3.5 {mu}m in height and 2.5 {mu}m in base diameter are fabricated with a tip radius of under 10 nm. The process is assisted by the formation of a layer of etch products which protects the newly forming tip from bending and over etching. The field emission current up to 50 {mu}A from the glassy carbon tips is obtained by applying high voltage to a mesh anode. The current which passed through the mesh anode is collected at another electrode and measured. The Fowler{endash}Nordheim plot suggests the existence of nm scale structure on the tip. This favorable result indicates glassy carbon substrate is a good substrate for field emitter arrays. {copyright} {ital 1997 American Vacuum Society.}

  12. Emitter Design and Numerical Simulation Based on the Extenics Theory

    Directory of Open Access Journals (Sweden)

    Jiang Fan

    2014-05-01

    Full Text Available In order to improve the performance of emitter, the extenics theory is introduced, whose divergent thinking is used to resolve the conflict of anti-clogging and energy dissipation and a new structure is proposed. The wide triangular areas are designed to reduce the flow rate behind of the each orifice and be easy to precipitation of impurities. The orifices are set to gradually decrease water kinetic energy and the flow channel is designed to be dismantle. The numerical simulation technology is used to analyze the internal flow field of emitter, the flow field results show that the improved emitter has great effect of energy dissipation and anti-clogging. As the same time, the structure of emitter is optimized and L1 = 31 mm, L2 = 21 mm, L3 = 8 mm and L4 = 5 mm are the optimization size values.

  13. FXR LIA Optimization - Time-resolved OTR Emittance Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, J; Ong, M; Wargo, P; LeSage, G

    2005-07-21

    The Flash X-Ray Radiography (FXR) facility at Lawrence Livermore National Laboratory utilizes a high current, long pulse linear induction accelerator to produce high doses of x-ray radiation. Accurate characterization of the transverse beam emittance is required in order to facilitate accelerator modeling and tuning efforts and, ultimately, to optimize the final focus spot size, yielding higher resolution radiographs. In addition to conventional magnet scan, pepper-pot, and multiple screen techniques, optical transition radiation (OTR) has been proven as a useful emittance measurement diagnostic and is particularly well suited to the FXR accelerator. We shall discuss the time-resolved emittance characterization of an induction linac electron beam using OTR, and we will present our experimental apparatus and analysis software. We shall also develop the theoretical background of beam emittance and transition radiation.

  14. Nanostructure-induced distortion in single-emitter microscopy

    CERN Document Server

    Lim, Kangmook; Fourkas, John; Shapiro, Benjamin; Waks, Edo

    2016-01-01

    Single-emitter microscopy has emerged as a promising method of imaging nanostructures with nanoscale resolution. This technique uses the centroid position of an emitters far-field radiation pattern to infer its position to a precision that is far below the diffraction limit. However, nanostructures composed of high-dielectric materials such as noble metals can distort the far-field radiation pattern. Nanoparticles also exhibit a more complex range of distortions, because in addition to introducing a high dielectric surface, they also act as efficient scatterers. Thus, the distortion effects of nanoparticles in single-emitter microscopy remains poorly understood. Here we demonstrate that metallic nanoparticles can significantly distort the accuracy of single-emitter imaging at distances exceeding 300 nm. We use a single quantum dot to probe both the magnitude and the direction of the metallic nanoparticle-induced imaging distortion and show that the diffraction spot of the quantum dot can shift by more than 35...

  15. Optimization of Metamaterial Selective Emitters for Use in Thermophotovoltaic Applications

    Science.gov (United States)

    Pfiester, Nicole A.

    The increasing costs of fossil fuels, both financial and environmental, has motivated many to look into sustainable energy sources. Thermophotovoltaics (TPVs), specialized photovoltaic cells focused on the infrared range, offer an opportunity to achieve both primary energy capture, similar to traditional photovoltaics, as well as secondary energy capture in the form of waste heat. However, to become a feasible energy source, TPV systems must become more efficient. One way to do this is through the development of selective emitters tailored to the bandgap of the TPV diode in question. This thesis proposes the use of metamaterial emitters as an engineerable, highly selective emitter that can withstand the temperatures required to collect waste heat. Metamaterial devices made of platinum and a dielectric such as alumina or silicon nitride were initially designed and tested as perfect absorbers. High temperature robustness testing demonstrates the device's ability to withstand the rigors of operating as a selective emitter.

  16. Absolute beam emittance measurements at RHIC using ionization profile monitors

    Energy Technology Data Exchange (ETDEWEB)

    Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Connolly, R [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Summers, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Tepikian, S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-08-15

    In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

  17. Transverse emittance measurement at REGAE via a solenoid scan

    Energy Technology Data Exchange (ETDEWEB)

    Hachmann, Max

    2012-12-15

    The linear accelerator REGAE at DESY produces short and low charged electron bunches, on the one hand to resolve the excitation transitions of atoms temporally by pump probe electron diffraction experiments and on the other hand to investigate principal mechanisms of laser plasma acceleration. For both cases a high quality electron beam is required. A quantity to rate the beam quality is the beam emittance. In the course of this thesis transverse emittance measurements by a solenoid scan could be realized and beyond that an improved theoretical description of a solenoid was successful. The foundation of emittance measurements are constituted by theoretical models which describe the envelope of a beam. Two different models were derived. The first is an often used model to determine the transverse beam emittance without considering space charge effects. More interesting and challenging was the development of an envelope model taking space charge effects into account. It is introduced and cross checked with measurements and simulations.

  18. CSR-induced emittance growth in achromats: Linear formalism revisited

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, M.

    2015-09-11

    We review the R-matrix formalism used to describe Coherent Synchrotron Radiation (CSR)-induced projected emittance growth in electron beam transport lines and establish the connection with a description in terms of the dispersion-invariant function.

  19. Emission Characteristics of Ion-Implanted Silicon Emitter Tips

    Science.gov (United States)

    Hirano, Takayuki; Kanemaru, Seigo; Tanoue, Hisao; Itoh, Junji

    1995-12-01

    An ion implantation technique has been applied to control the energy band structure of Si field-emitter tip surface. B+ or P+ ions were implanted after fabrication of a gated emitter structure. No changes in emitter structure were observed after ion implantation and successive annealing at 800° C. Current-voltage ( I-V ) characteristics of n, p, p/n and n/p emitter tips were measured: p/n indicates an n-type tip with B+ ions implanted into the tip surface. It was found from the experimental results that n and p/n tips had I-V characteristics in agreement with the Fowler-Nordheim theory. The p and n/p tips, on the other hand, exhibited a current saturation property in high electric field. The present saturation mechanism is explained by considering the energy band structure of the tip surface.

  20. Attribute measure recognition approach and its applications to emitter recognition

    Institute of Scientific and Technical Information of China (English)

    GUAN Xin; HE You; YI Xiao

    2005-01-01

    This paper studies the emitter recognition problem. A new recognition method based on attribute measure for emitter recognition is put forward. The steps of the method are presented. The approach to determining the weight coefficient is also discussed. Moreover, considering the temporal redundancy of emitter information detected by multi-sensor system, this new recognition method is generalized to multi-sensor system. A method based on the combination of attribute measure and D-S evidence theory is proposed. The implementation of D-S reasoning is always restricted by basic probability assignment function. Constructing basic probability assignment function based on attribute measure is presented in multi-sensor recognition system. Examples of recognizing the emitter purpose and system are selected to demonstrate the method proposed. Experimental results show that the performance of this new method is accurate and effective.

  1. Transverse Emittance Measurement and Preservation at the LHC

    CERN Document Server

    AUTHOR|(CDS)2082907

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation will be discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constra...

  2. Recent developments of low-emittance electron gun for accelerator

    International Nuclear Information System (INIS)

    Recent developments of low-emittance electron guns for accelerator are reviewed. In the accelerator field, DC biased triode thermionic gun (Pierce type gun) has been widely used and is still conventional. On the other hand, because of strong demands on the high brightness electron beam by FEL and other advanced accelerator concepts based on linear accelerator, the low emittance beam generation becomes one of the most important issue in the accelerator science. The R and D effort is 'accelerated' by two technological innovations, photo-cathode and RF gun. They made a large improvement on the beam emittance. After the explanations on the technical and physical aspects of the low emittance electron beam generation, advanced electron sources for accelerators are reviewed. (author)

  3. Localization of narrowband single photon emitters in nanodiamonds

    CERN Document Server

    Bray, Kerem; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-01-01

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bio-imaging. However, current understanding of the origin of these emitters is extremely limited. In this work we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond, and are directly relevant to fabrication of novel quantum optics devices and sensors.

  4. Beam Emittance Measurement for PLS-II Linac

    CERN Document Server

    Lee, Byung-Joon; Park, Chong do; Chunjarean, SomJai; Kim, Changbum

    2016-01-01

    The PLS-II has a 100 MeV pre-injector for the 3 GeV Linac. A thermionic gun produces electron charge of 200 pC with a bunch duration of 500 ps by a 250 ps triggering pulser. At the pre-injector, one of the most important beam parameters to identify the beam quality is a transverse emittance of electron bunches. Therefore we measure the beam emittance and twiss functions at 100 MeV in order to match the beam optics to beam transport line and go through it to the storage ring. To get the transverse emittance measurement, well-known technique, quadrupole scan, is used at the pre-injector. The emittance were 0.591 mm-mrad in horizontal and 0.774 mm-mrad in vertical direction.

  5. Innovative energy efficient low-voltage electron beam emitters

    International Nuclear Information System (INIS)

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates

  6. Intelligent Variable Emittance Panels Using New, ?True? Solid Electrolyte Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This firm has, in ongoing work in collaboration with the Air Force, NASA and JPL, developed a unique Variable Emittance technology based on the electrochromism of...

  7. Beam dynamics in rf guns and emittance correction techniques

    Science.gov (United States)

    Serafini, Luca

    1994-02-01

    In this paper we present a general review of beam dynamics in a laser-driven rf gun. The peculiarity of such an accelerating structure versus other conventional multi-cell linac structures is underlined on the basis of the Panofsky-Wenzel theorem, which is found to give a theoretical background for the well known Kim's model. A basic explanation for some proposed methods to correct rf induced emittance growth is also derived from the theorem. We also present three emittance correction techniques for the recovery of space-charge induced emittance growth, namely the optimum distributed disk-like bunch technique, the use of rf spatial harmonics to correct spherical aberration induced by space charge forces and the technique of emittance filtering by clipping the electron beam. The expected performances regarding the beam quality achievable with different techniques, as predicted by scaling laws and simulations, are analyzed, and, where available, compared to experimental results.

  8. Emittance of TD-NiCr after simulated reentry

    Science.gov (United States)

    Clark, R. K.; Dicus, D. L.; Lisagor, W. B.

    1978-01-01

    The effects of simulated reentry heating on the emittance of TD-NiCr were investigated. Groups of specimens with three different preconditioning treatments were exposed to 6, 24, and 30 half-hour simulated reentry exposure cycles in a supersonic arc tunnel at each of three conditions intended to produce surface temperatures of 1255, 1365, and 1475 K. Emittance was determined at 1300 K on specimens which were preconditioned only and specimens after completion of reentry simulation exposure. Oxide morphology and chemistry were studied by scanning electron microscopy and X-ray diffraction analysis. A consistent relationship was established between oxide morphology and total normal emittance. Specimens with coarser textured oxides tended to have lower emittances than specimens with finer textured oxides.

  9. CSR-induced emittance growth in achromats: Linear formalism revisited

    Science.gov (United States)

    Venturini, M.

    2015-09-01

    We review the R-matrix formalism used to describe Coherent Synchrotron Radiation (CSR)-induced projected emittance growth in electron beam transport lines and establish the connection with a description in terms of the dispersion-invariant function.

  10. Genetic ablation of root cap cells in Arabidopsis

    OpenAIRE

    Tsugeki, Ryuji; Fedoroff, Nina V.

    1999-01-01

    The root cap is increasingly appreciated as a complex and dynamic plant organ. Root caps sense and transmit environmental signals, synthesize and secrete small molecules and macromolecules, and in some species shed metabolically active cells. However, it is not known whether root caps are essential for normal shoot and root development. We report the identification of a root cap-specific promoter and describe its use to genetically ablate root caps by directing root cap-specific expression of...

  11. CAPS and INMS Major Accomplishments

    Science.gov (United States)

    Waite, J. Hunter

    2014-05-01

    The Cassini-Huygens Ion Neutral Mass Spectrometer (Cassini INMS) and the Cassini Plasma Spectrometer (CAPS) have provided "discovery" science at Titan, Enceladus, Rhea/Dione, and throughout the magnetosphere of Saturn during the course of the mission. In this talk we will review some of the major scientific achievements: 1) the discovery of an extremely complex ion neutral organic chemistry in Titan's upper atmosphere that forms the building blocks for aerosol processes below, 2) the discovery of gases and grains emanating from Enceladus' cryo-geysers that tell us about chemical processes in an interior sea, 3) the first direct compositional measurements of sputtered icy moon surfaces, 4) the clearest example to date of the complex plasma interchange processes that occur in rapidly rotating magnetospheres of gas giants, initiating global dynamic processes that enable Saturn to shed the plasma from Enceladus' plume, and complete with a myriad of longitudinal and solar local-time variations, and 5) the dominance of Enceladus water outgassing as a source of magnetospheric plasma that stretches out to Titan and provides oxygen that can convert Titan's rich nitrile populations into amino acids.

  12. A Program to Generate a Particle Distribution from Emittance Measurements

    CERN Document Server

    Bouma, DS; Lallement, JB

    2010-01-01

    We have written a program to generate a particle distribution based on emittance measurements in x-x’ and y-y’. The accuracy of this program has been tested using real and constructed emittance measurements. Based on these tests, the distribution generated by the program can be used to accurately simulate the beam in multi-particle tracking codes, as an alternative to a Gaussian or uniform distribution.

  13. Internal emitter limits for iodine, radium and radon daughters

    Energy Technology Data Exchange (ETDEWEB)

    Schlenker, R.A.

    1984-08-15

    This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

  14. Study of ultra-low emittance design for SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Wang, M. -H.; Huang, X.; Safranek, J.; /SLAC

    2015-09-17

    Since its 2003 construction, the SPEAR3 synchrotron light source at SLAC has continuously improved its performance by raising beam current, top-off injection, and smaller emittance. This makes SPEAR3 one of the most productive light sources in the world. Now, to further enhance the performance of SPEAR3, we are looking into the possibility of converting SPEAR3 to an ultra-low emittance storage ring within its site constraint.

  15. Internal emitter limits for iodine, radium and radon daughters

    International Nuclear Information System (INIS)

    This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (131I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables

  16. A Novel Depletion-Mode MOS Gated Emitter Shorted Thyristor

    Institute of Scientific and Technical Information of China (English)

    张鹤鸣; 戴显英; 张义门; 马晓华; 林大松

    2000-01-01

    A Novel MOS-gated thyristor, depletion-mode MOS gated emitter shorted thyristor (DMST),and its two structures are proposed. In DMST,the channel of depletion-mode MOS makes the thyristor emitter-based junction inherently short. The operation of the device is controlled by the interruption and recovery of the depletion-mode MOS P channel. The perfect properties have been demonstrated by 2-D numerical simulations and the tests on the fabricated chips.

  17. Lambertian thermal emitter based on plasmonic enhanced absorption.

    Science.gov (United States)

    Wang, Chih-Ming; Tsai, Din Ping

    2016-08-01

    In this paper, a narrow band thermal emission at 10 μm is demonstrated using a one dimensional metasurface. The proposed metasurface structure provides magnetic resonance mode that enhances the phonon absorption of SiO2. The proposed metasurface thermal emitter shows a Lambertian distribution. Additionally, 5.8-folds enhancement of emissivity is achieved by optimizing the cavity thickness of the metasurfaces. This type of thermal emitter will be useful for IR sensing applications. PMID:27505801

  18. Optimization of the emittance of electrons (positrons) storage rings

    International Nuclear Information System (INIS)

    An important parameter of the source characteristics of a synchrotron radiation facility, is the beam emittance. The general structure presently adopted, is of the achromatic arc, or adapted dispersion type. This structure allows analytical treatment of dispersion and β function in the arcs, and then, the minimization of the dimension invariant. Practical formulae are given, allowing scaling of momentum compaction factor, minimum emittance limit and β value in the magnets. Limitations in chromaticity correction possibilities are also discussed

  19. Ab initio alpha-alpha scattering

    CERN Document Server

    Elhatisari, Serdar; Rupak, Gautam; Epelbaum, Evgeny; Krebs, Hermann; Lähde, Timo A; Luu, Thomas; Meißner, Ulf-G

    2015-01-01

    Processes involving alpha particles and alpha-like nuclei comprise a major part of stellar nucleosynthesis and hypothesized mechanisms for thermonuclear supernovae. In an effort towards understanding alpha processes from first principles, we describe in this letter the first ab initio calculation of alpha-alpha scattering. We use lattice effective field theory to describe the low-energy interactions of nucleons and apply a technique called the adiabatic projection method to reduce the eight-body system to an effective two-cluster system. We find good agreement between lattice results and experimental phase shifts for S-wave and D-wave scattering. The computational scaling with particle number suggests that alpha processes involving heavier nuclei are also within reach in the near future.

  20. Thin Emitter Structure Improved Turn-on Characteristics in RSD

    Institute of Scientific and Technical Information of China (English)

    LIANG Lin; YU Yuehui; ZHOU Yuming; WANG Lu

    2008-01-01

    The thin emitter structure was introduced into reversely switched dynistor (RSD) to improve its turn-on characteristics. According to the analysis of turn-on condition, thin emitter structure is capable of reducing the extraction action for the triggering plasma layer P1 during turn-on process, and satisfying the requirement that triggering electric charge cannot be exhausted and therefore enables RSD to turn on uniformly. The on-state thin emitter RSD was equivalent to an asymmetric pin diode model. The simulation result shows that the forward voltage drop of RSD falls with the decrease of doping dose in p+-emitter in a certain range, and when the doping concentration is extremely low, the decrease of the width of p+-emitter can obtain a low forward voltage drop. Thin emitter RSD chips were made by sintering Al on n-Si. The test result shows that their turn-on process is uniform and the voltage drop is 7.5V when the peak conversion current is 5500A.

  1. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    Directory of Open Access Journals (Sweden)

    Guag Joshua W

    2011-06-01

    Full Text Available Abstract Background The objective of this study is to investigate electromagnetic compatibility (EMC of implantable neurostimulators with the emissions from radio frequency identification (RFID emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  2. Validated Analytical Model of a Pressure Compensation Drip Irrigation Emitter

    Science.gov (United States)

    Shamshery, Pulkit; Wang, Ruo-Qian; Taylor, Katherine; Tran, Davis; Winter, Amos

    2015-11-01

    This work is focused on analytically characterizing the behavior of pressure-compensating drip emitters in order to design low-cost, low-power irrigation solutions appropriate for off-grid communities in developing countries. There are 2.5 billion small acreage farmers worldwide who rely solely on their land for sustenance. Drip, compared to flood, irrigation leads to up to 70% reduction in water consumption while increasing yields by 90% - important in countries like India which are quickly running out of water. To design a low-power drip system, there is a need to decrease the pumping pressure requirement at the emitters, as pumping power is the product of pressure and flow rate. To efficiently design such an emitter, the relationship between the fluid-structure interactions that occur in an emitter need to be understood. In this study, a 2D analytical model that captures the behavior of a common drip emitter was developed and validated through experiments. The effects of independently changing the channel depth, channel width, channel length and land height on the performance were studied. The model and the key parametric insights presented have the potential to be optimized in order to guide the design of low-pressure, clog-resistant, pressure-compensating emitters.

  3. The pharmaceutical vial capping process: Container closure systems, capping equipment, regulatory framework, and seal quality tests.

    Science.gov (United States)

    Mathaes, Roman; Mahler, Hanns-Christian; Buettiker, Jean-Pierre; Roehl, Holger; Lam, Philippe; Brown, Helen; Luemkemann, Joerg; Adler, Michael; Huwyler, Joerg; Streubel, Alexander; Mohl, Silke

    2016-02-01

    Parenteral drug products are protected by appropriate primary packaging to protect against environmental factors, including potential microbial contamination during shelf life duration. The most commonly used CCS configuration for parenteral drug products is the glass vial, sealed with a rubber stopper and an aluminum crimp cap. In combination with an adequately designed and controlled aseptic fill/finish processes, a well-designed and characterized capping process is indispensable to ensure product quality and integrity and to minimize rejections during the manufacturing process. In this review, the health authority requirements and expectations related to container closure system quality and container closure integrity are summarized. The pharmaceutical vial, the rubber stopper, and the crimp cap are described. Different capping techniques are critically compared: The most common capping equipment with a rotating capping plate produces the lowest amount of particle. The strength and challenges of methods to control the capping process are discussed. The residual seal force method can characterize the capping process independent of the used capping equipment or CCS. We analyze the root causes of several cosmetic defects associated with the vial capping process.

  4. Capping stack: An industry in the making

    Institute of Scientific and Technical Information of China (English)

    Jack Chen; Li Xunke; Xie Wenhui; Kang Yongtian

    2013-01-01

    This paper gives an overview of recent development of the marine well containment system (MWCS)after BP Macondo subsea well blowout occurred on April 20,2010 in the Gulf of Mexico.Capping stack,a hardware utilized to contain blowout well at or near the wellhead is the center piece of MWCS.Accessibility to the dedicated capping stacks is gradually becoming a pre-requirement to obtain the permit for offshore drilling/workover,and the industry for manufacturing,maintenance,transportation and operation of the capping stack is in the making.

  5. Silicon Carbide Emitter Turn-Off Thyristor

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2008-01-01

    Full Text Available A novel MOS-controlled SiC thyristor device, the SiC emitter turn-off thyristor (ETO is a promising technology for future high-voltage switching applications because it integrates the excellent current conduction capability of a SiC thyristor with a simple MOS-control interface. Through unity-gain turn-off, the SiC ETO also achieves excellent Safe Operation Area (SOA and faster switching speeds than silicon ETOs. The world's first 4.5-kV SiC ETO prototype shows a forward voltage drop of 4.26 V at 26.5 A/cm2 current density at room and elevated temperatures. Tested in an inductive circuit with a 2.5 kV DC link voltage and a 9.56-A load current, the SiC ETO shows a fast turn-off time of 1.63 microseconds and a low 9.88 mJ turn-off energy. The low switching loss indicates that the SiC ETO could operate at about 4 kHz if 100 W/cm2 conduction and the 100 W/cm2 turn-off losses can be removed by the thermal management system. This frequency capability is about 4 times higher than 4.5-kV-class silicon power devices. The preliminary demonstration shows that the SiC ETO is a promising candidate for high-frequency, high-voltage power conversion applications, and additional developments to optimize the device for higher voltage (>5 kV and higher frequency (10 kHz are needed.

  6. Remote system for measurement of radon alpha emitter for population safety guards

    International Nuclear Information System (INIS)

    The objective of this research project is to study the OSL properties for high doses of dosemeters traditionally applied in thermoluminescent dosimetry (TL), as CaF2: Dy (TLD 200) and CaF2: Mn (TLD 400), and thus verify the applicability of OSL technique in high-dose dosimetry

  7. Circumpolar Active-Layer Permafrost System (CAPS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Circumpolar Active-Layer Permafrost System (CAPS) contains over 100 data sets pertaining to permafrost and frozen ground topics. It also contains detailed...

  8. C-CAP Land Cover, Niihau, Hawaii

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change Analysis Program (C-CAP) protocol to determine...

  9. C-CAP Land Cover, Molokai, Hawaii

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change Analysis Program (C-CAP) protocol to determine...

  10. C-CAP Land Cover, Lanai, Hawaii

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change Analysis Program (C-CAP) protocol to determine...

  11. Mapping of p140Cap phosphorylation sites

    DEFF Research Database (Denmark)

    Repetto, Daniele; Aramu, Simona; Boeri Erba, Elisabetta;

    2013-01-01

    protein, in which both EPLYA/EGLYA tyrosines were converted to phenylalanine, was no longer tyrosine phosphorylated, despite the presence of other tyrosine residues in p140Cap sequence. Moreover, this mutant lost its ability to bind the C-terminal Src kinase (Csk), previously shown to interact with p140...... phosphorylation and tunes its interactions with other regulatory molecules via post-translation modification. In this work, using mass spectrometry, we found that p140Cap is in vivo phosphorylated on tyrosine (Y) within the peptide GEGLpYADPYGLLHEGR (from now on referred to as EGLYA) as well as on three serine...... residues. Consistently, EGLYA has the highest score of in silico prediction of p140Cap phosphorylation. To further investigate the p140Cap function, we performed site specific mutagenesis on tyrosines inserted in EGLYA and EPLYA, a second sequence with the same highest score of phosphorylation. The mutant...

  12. C-CAP Hawaii 2005 Land Cover

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change Analysis Program (C-CAP) protocol to determine...

  13. C-CAP Land Cover, Maui, Hawaii

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of land derived from high resolution imagery and was analyzed according to the Coastal Change Analysis Program (C-CAP) protocol to determine...

  14. Ab initio alpha-alpha scattering

    Science.gov (United States)

    Elhatisari, Serdar; Lee, Dean; Rupak, Gautam; Epelbaum, Evgeny; Krebs, Hermann; Lähde, Timo A.; Luu, Thomas; Meißner, Ulf-G.

    2015-12-01

    Processes such as the scattering of alpha particles (4He), the triple-alpha reaction, and alpha capture play a major role in stellar nucleosynthesis. In particular, alpha capture on carbon determines the ratio of carbon to oxygen during helium burning, and affects subsequent carbon, neon, oxygen, and silicon burning stages. It also substantially affects models of thermonuclear type Ia supernovae, owing to carbon detonation in accreting carbon-oxygen white-dwarf stars. In these reactions, the accurate calculation of the elastic scattering of alpha particles and alpha-like nuclei—nuclei with even and equal numbers of protons and neutrons—is important for understanding background and resonant scattering contributions. First-principles calculations of processes involving alpha particles and alpha-like nuclei have so far been impractical, owing to the exponential growth of the number of computational operations with the number of particles. Here we describe an ab initio calculation of alpha-alpha scattering that uses lattice Monte Carlo simulations. We use lattice effective field theory to describe the low-energy interactions of protons and neutrons, and apply a technique called the ‘adiabatic projection method’ to reduce the eight-body system to a two-cluster system. We take advantage of the computational efficiency and the more favourable scaling with system size of auxiliary-field Monte Carlo simulations to compute an ab initio effective Hamiltonian for the two clusters. We find promising agreement between lattice results and experimental phase shifts for s-wave and d-wave scattering. The approximately quadratic scaling of computational operations with particle number suggests that it should be possible to compute alpha scattering and capture on carbon and oxygen in the near future. The methods described here can be applied to ultracold atomic few-body systems as well as to hadronic systems using lattice quantum chromodynamics to describe the interactions of

  15. Ab initio alpha-alpha scattering.

    Science.gov (United States)

    Elhatisari, Serdar; Lee, Dean; Rupak, Gautam; Epelbaum, Evgeny; Krebs, Hermann; Lähde, Timo A; Luu, Thomas; Meißner, Ulf-G

    2015-12-01

    Processes such as the scattering of alpha particles ((4)He), the triple-alpha reaction, and alpha capture play a major role in stellar nucleosynthesis. In particular, alpha capture on carbon determines the ratio of carbon to oxygen during helium burning, and affects subsequent carbon, neon, oxygen, and silicon burning stages. It also substantially affects models of thermonuclear type Ia supernovae, owing to carbon detonation in accreting carbon-oxygen white-dwarf stars. In these reactions, the accurate calculation of the elastic scattering of alpha particles and alpha-like nuclei--nuclei with even and equal numbers of protons and neutrons--is important for understanding background and resonant scattering contributions. First-principles calculations of processes involving alpha particles and alpha-like nuclei have so far been impractical, owing to the exponential growth of the number of computational operations with the number of particles. Here we describe an ab initio calculation of alpha-alpha scattering that uses lattice Monte Carlo simulations. We use lattice effective field theory to describe the low-energy interactions of protons and neutrons, and apply a technique called the 'adiabatic projection method' to reduce the eight-body system to a two-cluster system. We take advantage of the computational efficiency and the more favourable scaling with system size of auxiliary-field Monte Carlo simulations to compute an ab initio effective Hamiltonian for the two clusters. We find promising agreement between lattice results and experimental phase shifts for s-wave and d-wave scattering. The approximately quadratic scaling of computational operations with particle number suggests that it should be possible to compute alpha scattering and capture on carbon and oxygen in the near future. The methods described here can be applied to ultracold atomic few-body systems as well as to hadronic systems using lattice quantum chromodynamics to describe the interactions of

  16. Design and implementation of the CAPS receiver

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    In this paper, based on analyses of the Chinese Area Positioning System (CAPS) satellite (GEO satellite) resources and signal properties, the signal power at the port of the receiver antenna is estimated, and the implementation projects are presented for a switching band C to band L CAPS C/A code receiver integrated with GPS receiver suite and for a CAPS dual frequency P code receiver. A microstrip receiving antenna is designed with high sensitivity and wide beam orientation, the RF front end of the C/A code and P code receivers, and a processor is designed for the navigation baseband. A single frequency CAPS C/A code receiver and a CAPS dual frequency P code receiver are built at the same time. A software process flow is provided, and research on relatively key techniques is also conducted, such as signal searching, code loop and carrier loop algorithms, a height assistant algorithm, a dual frequency difference speed measurement technique, a speed measurement technique using a single frequency source with frequency assistance, and a CAPS time correcting algorithm, according to the design frame of the receiver hardware. Research results show that the static plane positioning accuracy of the CAPS C/A code receiver is 20.5-24.6 m, height accuracy is 1.2-12.8 m, speed measurement accuracy is 0.13-0.3 m/s, dynamic plane positioning accuracy is 24.4 m, height accuracy is 3.0 m, and speed measurement accuracy is 0.24 m/s. In the case of C/A code, the timing accuracy is 200 ns, and it is also shown that the positioning accuracy of the CAPS precise code receiver (1σ ) is 5 m from south to north, and 0.8 m from east to west. Finally, research on positioning accuracy is also conducted.

  17. UNDERSTANDING FARMERS’ RESPONSES TO CAP REFORM

    OpenAIRE

    Menozzi, Davide; Fioravanzi, Martina; Donati, Michele

    2014-01-01

    The 2014-2020 Common Agricultural Policy (CAP) reform defines new rules for farmers including regionalization, crop diversification and ecological focus area (EFA). This paper aims to evaluate farmers’ intention to modify their behaviour because of the CAP reform, using the Theory of Planned Behaviour (TPB). A questionnaire was submitted to 71 Italian durum wheat producers assessing their intention to change durum wheat surface and to maintain as EFA part of the arable land. Subjective norms ...

  18. Emittance and Phase Space Tomography for the Fermilab Linac

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, F.G.G.; Johnstone, C.; Kobilarcik, T.; Koizumi, G.M.; Moore, C.D.; /Fermilab; Newhart, D.L.; /Fermilab

    2012-05-01

    The Fermilab Linac delivers a variable intensity, 400-MeV beam to the MuCool Test Area experimental hall via a beam line specifically designed to facilitate measurements of the Linac beam emittance and properties. A 10 m, dispersion-free and magnet-free straight utilizes an upstream quadrupole focusing triplet in combination with the necessary in-straight beam diagnostics to fully characterize the transverse beam properties. Since the Linac does not produce a strictly elliptical phase space, tomography must be performed on the profile data to retrieve the actual particle distribution in phase space. This is achieved by rotating the phase space distribution using different waist focusing conditions of the upstream triplet and performing a deconvolution of the profile data. Preliminary measurements using this diagnostic section are reported here. These data represent a first-pass measurement of the Linac emittance based on various techniques. It is clear that the most accurate representation of the emittance is given by the 3-profile approach. Future work will entail minimizing the beam spot size on MW5 to test and possibly improve the accuracy of the 2-profile approach. The 95% emittance is {approx} 18{pi} in the vertical and {approx} 13{pi} in the horizontal, which is especially larger than anticipated - 8-10{pi} was expected. One possible explanation is that the entire Linac pulse is extracted into the MTA beamline and during the first few microseconds, the feed forward and RF regulation are not stable. This may result in a larger net emittance observed versus beam injected into Booster, where the leading part of the Linac beam pulse is chopped. Future studies will clearly entail a measurement of the emittance vs. pulse length. One additional concern is that the Linac phase space is most likely aperture-defined and non-elliptical in nature. A non-elliptical phase-space determination would require a more elaborate analysis and provide another explanation of the

  19. Faddeev calculation of 3 alpha and alpha alpha Lambda systems using alpha alpha resonating-group method kernel

    CERN Document Server

    Fujiwara, Y; Kohno, M; Suzuki, Y; Baye, D; Sparenberg, J M

    2004-01-01

    We carry out Faddeev calculations of three-alpha (3 alpha) and two-alpha plus Lambda (alpha alpha Lambda) systems, using two-cluster resonating-group method kernels. The input includes an effective two-nucleon force for the alpha alpha resonating-group method and a new effective Lambda N force for the Lambda alpha interaction. The latter force is a simple two-range Gaussian potential for each spin-singlet and triplet state, generated from the phase-shift behavior of the quark-model hyperon-nucleon interaction, fss2, by using an inversion method based on supersymmetric quantum mechanics. Owing to the exact treatment of the Pauli-forbidden states between the clusters, the present three-cluster Faddeev formalism can describe the mutually related, alpha alpha, 3 alpha and alpha alpha Lambda systems, in terms of a unique set of the baryon-baryon interactions. For the three-range Minnesota force which describes the alpha alpha phase shifts quite accurately, the ground-state and excitation energies of 9Be Lambda are...

  20. Optimisation study of {alpha}-cyclotron production of At-211/Po-211g for high-LET metabolic radiotherapy purposes

    Energy Technology Data Exchange (ETDEWEB)

    Groppi, F. [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, I-20090 Segrate, Milan (Italy)]. E-mail: flavia.groppi@mi.infn.it; Bonardi, M.L. [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, I-20090 Segrate, Milan (Italy); Birattari, C. [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, I-20090 Segrate, Milan (Italy); Menapace, E. [ENEA, Division for Advanced Physics Technologies, via Don Fiammelli 2, I-40128 Bologna (Italy); Abbas, K. [Institute for Health and Consumer Protection, IHCP, JRC-Ispra, via E. Fermi, I-21020 Varese (Italy); Holzwarth, U. [Institute for Health and Consumer Protection, IHCP, JRC-Ispra, via E. Fermi, I-21020 Varese (Italy); Alfarano, A. [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, I-20090 Segrate, Milan (Italy); Institute for Health and Consumer Protection, IHCP, JRC-Ispra, via E. Fermi, I-21020 Varese (Italy); Morzenti, S. [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, I-20090 Segrate, Milan (Italy); Zona, C. [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, I-20090 Segrate, Milan (Italy); Alfassi, Z.B. [Department of Nuclear Engineering, Ben Gurion University of Negev, Beer-Sheva, Il-84105 (Israel)

    2005-12-01

    The production of no-carrier-added (NCA) {alpha}-emitter {sup 211}At/{sup 211g}Po radionuclides for high-LET targeted radiotherapy and immunoradiotherapy, through the {sup 209}Bi({alpha},2n) reaction, together with the required wet radiochemistry and radioanalytical quality controls carried out at LASA is described, through dedicated irradiation experiments at the MC-40 cyclotron of JRC-Ispra. The amount of both the {gamma}-emitter {sup 210}At and its long half-lived {alpha}-emitting daughter {sup 210}Po is optimised and minimised by appropriate choice of energy and energy loss of {alpha} particle beam. The measured excitation functions for production of the main radioisotopic impurity {sup 210}At{yields}{sup 210}Po are compared with theoretical predictions from model calculations performed at ENEA.

  1. Effect of water alpha radiolysis on the spent nuclear fuel UO2 matrix alteration

    International Nuclear Information System (INIS)

    Leaching experiments with solution renewal were carried out on UO2 pellets doped with alpha emitters (238/239Pu) to quantify the impact of alpha irradiation on UO2 matrix alteration. Three batches of doped UO2 pellets with different alpha flux levels were studied as well as spent fuel fragments. Interim storage in air of UO2 pellets doped with alpha emitters results in variations of the UO2 surface reactivity, which depends on the alpha particle flux at the interface and on the interim storage duration. The variation in the surface reactivity and the greater uranium release following interim storage cannot be attributed to the effect of alpha radiolysis in aerated media since the uranium release tends toward the same value after several leaching cycles for the doped UO2 pellet batches and spent fuel. However, leaching experiments performed in deaerated media after annealing the samples and pre-leaching the surface suggest that alpha radiolysis does indeed affect the dissolution, which varies with the flux at the UO2/water interface. (authors)

  2. Tuning the Magnetic Transport of an Induction LINAC using Emittance

    Energy Technology Data Exchange (ETDEWEB)

    Houck, T L; Brown, C G; Ong, M M; Paul, A C; Wargo, P E; Zentler, J M

    2006-08-11

    The Lawrence Livermore National Laboratory Flash X-Ray (FXR) machine is a linear induction accelerator used to produce a nominal 18 MeV, 3 kA, 65 ns pulse width electron beam for hydrodynamic radiographs. A common figure of merit for this type of radiographic machine is the x-ray dose divided by the spot area on the bremsstrahlung converter where a higher FOM is desired. Several characteristics of the beam affect the minimum attainable x-ray spot size. The most significant are emittance (chaotic transverse energy), chromatic aberration (energy variation), and beam motion (transverse instabilities and corkscrew motion). FXR is in the midst of a multi-year optimization project to reduce the spot size. This paper describes the effort to reduce beam emittance by adjusting the fields of the transport solenoids and position of the cathode. If the magnetic transport is not correct, the beam will be mismatched and undergo envelope oscillations increasing the emittance. We measure the divergence and radius of the beam in a drift section after the accelerator by imaging the optical transition radiation (OTR) and beam envelope on a foil. These measurements are used to determine an emittance. Relative changes in the emittance can be quickly estimated from the foil measurements allowing for an efficient, real-time study. Once an optimized transport field is determined, the final focus can be adjusted and the new x-ray spot measured. A description of the diagnostics and analysis is presented.

  3. Field emitter arrays for plasma and microwave source applications

    Science.gov (United States)

    Jensen, K. L.

    1999-05-01

    Field emitter arrays (FEAs) stand to strongly impact device performance when physical size, weight, power consumption, beam current, and/or high pulse repetition frequencies are an issue. FEAs are capable of instant ON/OFF performance, high brightness, high current density, large transconductance to capacitance ratio, and low voltage operation characteristics. Advanced microwave power tubes, and in particular, inductive output amplifiers, are by far the most technically challenging use to date. Other important uses include, e.g., electron sources for micropropulsion systems-Hall thrusters-and tethers for satellites, and (the most widely pursued application) field emission displays. The characteristics of field emitters that make them attractive to such applications shall be surveyed. A thorough analytical model of a field emitter array, beginning with a review of the nature of field emission and continuing with an analytical model of a single emitter and the operation of an array of emitters, shall be presented. In particular, attention shall be directed towards those features of FEAs that render them attractive as cold cathode candidates for electron beam generation. Tip characteristics, such as emission distribution, and array operation, such as space charge effects, will be analyzed in the context of the model. Finally, restricting attention to microwave applications, the performance of a tapered-helix inductive output amplifier to highlight the advantages of high frequency emission gating of the electron beam in a power tube shall be investigated.

  4. Quantitative Single-Particle Digital Autoradiography with α-Particle Emitters for Targeted Radionuclide Therapy using the iQID Camera

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Brian W.; Frost, Sophia; Frayo, Shani; Kenoyer, Aimee L.; Santos, E. B.; Jones, Jon C.; Green, Damian J.; Hamlin, Donald K.; Wilbur, D. Scott; Fisher, Darrell R.; Orozco, Johnnie J.; Press, Oliver W.; Pagel, John M.; Sandmaier, B. M.

    2015-07-01

    Abstract Alpha emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm) causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with alpha emitters may inactivate targeted cells with minimal radiation damage to surrounding tissues. For accurate dosimetry in alpha-RIT, tools are needed to visualize and quantify the radioactivity distribution and absorbed dose to targeted and non-targeted cells, especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, iQID (ionizing-radiation Quantum Imaging Detector), for use in alpha-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection technology that images and identifies charged-particle and gamma-ray/X-ray emissions spatially and temporally on an event-by-event basis. It employs recent advances in CCD/CMOS cameras and computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, we evaluated this system’s characteristics for alpha particle imaging including measurements of spatial resolution and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 (211At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ~20 μm full width at half maximum (FWHM) and the alpha particle background was measured at a rate of (2.6 ± 0.5) × 10–4 cpm/cm2 (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm

  5. 75 FR 49527 - Caps Visual Communications, LLC; Black Dot Group; Formerly Known as Caps Group Acquisition, LLC...

    Science.gov (United States)

    2010-08-13

    ... Employment and Training Administration Caps Visual Communications, LLC; Black Dot Group; Formerly Known as... Adjustment Assistance on June 24, 2010, applicable to workers of Caps Visual Communications, LLC, Black Dot..., Caps Visual Communications, LLC, Black Dot Group, formerly known as Caps Group Acquisition,...

  6. Review of alpha_s determinations

    CERN Document Server

    Pich, Antonio

    2013-01-01

    The present knowledge on the strong coupling is briefly summarized. The most precise determinations of alpha_s, at different energies, are reviewed and compared at the Z mass scale, using the predicted QCD running. The impressive agreement achieved between experimental measurements and theoretical predictions constitutes a beautiful and very significant test of Asymptotic Freedom, establishing QCD as the fundamental theory of the strong interaction. The world average value of the strong coupling is found to be alpha_s(M_Z^2)= 0.1186 \\pm 0.0007.

  7. Scenarios for a cap beyond 2013; Implications for EU27 agriculture and the cap budget

    NARCIS (Netherlands)

    Helming, J.F.M.; Terluin, I.J.

    2011-01-01

    An ex ante analysis of a set of five policy components (proposed post 2013 CAP measures) has been carried out for the 2014-2020 period, based on the EC Communication The CAP towards 2020 of 18 November 2010. The policy components are defined in such a way that they focus on the contribution of farme

  8. Emittance measurements results with upgraded setup at PITZ

    Energy Technology Data Exchange (ETDEWEB)

    Vashchenko, Grygorii; Asova, Galina; Gross, Matthias; Hakobyan, Levon; Isaev, Igor; Ivanisenko, Yevgeniy; Khojoyan, Martin; Klemz, Guido; Krasilnikov, Mikhail; Mahgoub, Mahmoud; Malyutin, Dmitriy; Otevrel, Marek; Petrosyan, Bagrat; Riechter, Dieter; Rimjaem, Sakhorn; Shapovalov, Andrey; Stephan, Frank [DESY, Zeuthen (Germany); Nozdrin, Mikhail [JINR, Dubna (Russian Federation); Templin, Horst-Ingo; Will, Ingo [MBI, Berlin (Germany)

    2012-07-01

    The photo injector test facility at DESY, Zeuthen site, PITZ develops and characterizes photoelectron sources for linac driven free electron lasers (FELs) such as FLASH and the European XFEL. The main goal of the PITZ is to obtain electron beams with low transverse normalize emittance which is necessary for the successful operation of SASE FEL. Major parts of the facility - gun and booster cavities, photocathode laser system were upgraded in 2010 in order to improve the photo injector performance. A slit technique is used at PITZ to reconstruct the transverse phase space of the electron beam. Many machine parameters were tuned to optimize the beam emittance for a wide range of the bunch charge - from 20 pC to 2 nC. Measured emittance depending on various machine parameters like a gun launching phase, booster gradient, laser spot size on the cathode and main solenoid current is presented.

  9. A Review on Multiple Emitter Location and Signal Parameter Estimation

    Directory of Open Access Journals (Sweden)

    Sandeep Santosh, Karan Sharma

    2013-07-01

    Full Text Available Processing the signals received on an array of sensors for the location of the emitter is of great enough interest to have been treated under many special case assumptions. The general problem considers sensors with arbitrary locations and arbitrary directional characteristics (gain phase polarization in a noise/interference environment of arbitrary covariance matrix. This report is concerned first with the multiple emitter aspect of this problem and second with the generality of solution. A description is given of the multiple signal classification (MUSIC algorithm, which provides asymptotically unbiased estimates of 1 number of incident wavefronts present; 2 directions of arrival (DOA (or emitter locations; 3 strengths and cross correlations among the incident waveforms; 4 noise/interference strength. Examples and comparisons with methods based on maximum likelihood (ML and maximum entropy (ME, as well as conventional beamforming are. included. An example of its use as a multiple frequency estimator operating on time series is included.

  10. Hybrid genetic optimization for design of photonic crystal emitters

    Science.gov (United States)

    Rammohan, R. R.; Farfan, B. G.; Su, M. F.; El-Kady, I.; Reda Taha, M. M.

    2010-09-01

    A unique hybrid-optimization technique is proposed, based on genetic algorithms (GA) and gradient descent (GD) methods, for the smart design of photonic crystal (PhC) emitters. The photonic simulation is described and the granularity of photonic crystal dimensions is considered. An innovative sliding-window method for performing local heuristic search is demonstrated. Finally, the application of the proposed method on two case studies for the design of a multi-pixel photonic crystal emitter and the design of thermal emitter in thermal photovoltaic is demonstrated. Discussion in the report includes the ability of the optimal PhC structures designed using the proposed method, to produce unprecedented high emission efficiencies of 54.5% in a significantly long wavelength region and 84.9% at significantly short wavelength region.

  11. Hole emitter whispering galleries of photonic quantum ring

    CERN Document Server

    Kwon, O; an, S J; Kim, D K; Lee, S E; Bae, J; Yoon, J H; Park, B H; Kim, J; Ahn, J; Park, S; Kwon, Odae

    2005-01-01

    We report on the first observation of hole whispering gallery lasers from semiconductor microcavities with three dimensional optical confinement, with thresholds potentially reducible to micro-to-nano ampere regimes according to a quadratic size-dependent reduction, due to ideal quantum wire properties of the naturally formed photonic quantum rings before imminent recombination in a dynamic steady state fashion. If the device size grows over a critical diameter, the quantum ring whispering gallery then begins to disappear. However, cooperative small hole arrays like 256x256 quantum ring emitters avoid the criticality and open a possibility of constructing practical dense electro-pumped micro-to-nano watt emitter arrays, amenable to mega-to-giga ring emitter chip development via present fabrication techniques.

  12. On the measurement of positron emitters with Ge detectors

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, Virginia, E-mail: virginia.peyres@ciemat.e [Ciemat, Laboratorio de Metrologia de Radiaciones Ionizantes, Avda. Complutense 22, Madrid 28040 (Spain); Garcia-Torano, Eduardo [Ciemat, Laboratorio de Metrologia de Radiaciones Ionizantes, Avda. Complutense 22, Madrid 28040 (Spain)

    2011-05-01

    This paper discusses the problems related to the measurement of positron emitters with germanium detectors. Five positron emitters with important applications in nuclear medicine ({sup 22}Na, {sup 18}F, {sup 11}C, {sup 13}N and {sup 68}Ga) have been studied. Measurements and Monte Carlo simulations have been used to determine the optimal conditions of measurement in gamma-ray spectrometry systems. The results obtained indicate that adding adequate absorbers, detection efficiencies are close to those of gamma emitters of similar energy measured in the same conditions, which allows a rapid calibration of a Ge-based spectrometry system. More accurate results are also presented using a detailed Monte Carlo simulation. Comparison to experimental data shows a good agreement.

  13. DC-SC Photoinjector with Low Emittance at Peking University

    CERN Document Server

    Xiang Rong; Hao, J; Huang, Senlin; Lu Xiang Yang; Quan, Shengwen; Zhang, Baocheng; Zhao, Kui

    2005-01-01

    High average power Free Electron Lasers require the high quality electron beams with the low emittance and the sub-picosecond bunches. The design of DC-SC photoinjector, directly combining a DC photoinjector with an SRF cavity, can produce high average current beam with moderate bunch charge and high duty factor. Because of the DC gun, the emittance increases quickly at the beginning, so a carefully design is needed to control that. In this paper, the simulation of an upgraded design has been done to lower the normalized emittance below 1.5mm·mrad. The photoinjector consists of a DC gap and a 2+1/2-cell SRF cavity, and it is designed to produce 4.2 MeV electron beams at 100pC bunch charge and 81.25MHz repetition rate (8 mA average current).

  14. Emittance growth in the DARHT Axis-II Downstream Transport

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Jr., Carl August [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schulze, Martin E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-14

    Using a particle-in-cell (PIC) code, we investigated the possibilities for emittance growth through the quadrupole magnets of the system used to transport the high-current electron beam from an induction accelerator to the bremsstrahlung converter target used for flash radiography. We found that even highly mismatched beams exhibited little emittance growth (< 6%), which we attribute to softening of their initial hard edge current distributions. We also used this PIC code to evaluate the accuracy of emittance measurements using a solenoid focal scan following the quadrupole magnets. If the beam is round after the solenoids, the simulations indicate that the measurement is highly accurate, but it is substantially inaccurate for elliptical beams

  15. Fully tuneable, Purcell-enhanced solid-state quantum emitters

    Energy Technology Data Exchange (ETDEWEB)

    Petruzzella, M., E-mail: m.petruzzella@tue.nl; Xia, T.; Pagliano, F.; Birindelli, S.; Zobenica, Z.; Fiore, A. [COBRA Research Institute, Eindhoven University of Technology, P.O. Box 513, NL-5600MB Eindhoven (Netherlands); Midolo, L. [Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, DK-2100 Copenhagen (Denmark); Li, L. H.; Linfield, E. H. [School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom)

    2015-10-05

    We report the full energy control over a semiconductor cavity-emitter system, consisting of single Stark-tunable quantum dots embedded in mechanically reconfigurable photonic crystal membranes. A reversible wavelength tuning of the emitter over 7.5 nm as well as an 8.5 nm mode shift are realized on the same device. Harnessing these two electrical tuning mechanisms, a single exciton transition is brought on resonance with the cavity mode at several wavelengths, demonstrating a ten-fold enhancement of its spontaneous emission. These results open the way to bring several cavity-enhanced emitters mutually into resonance and therefore represent a key step towards scalable quantum photonic circuits featuring multiple sources of indistinguishable single photons.

  16. Emittance measurements for the Illinois/CEBAF polarized electron source

    Energy Technology Data Exchange (ETDEWEB)

    Dunham, B.M.; Cardman, L.S. [Illinois Univ., Urbana, IL (United States); Sinclair, C.K. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States)

    1995-01-01

    The transverse thermal properties of the electrons photoemitted from GaAs determine the intrinsic beam emittance, an important quantity in applications such as polarized electron sources and high-brightness sources. In this paper, emittance measurements using the Illinois/CEBAF polarized electron source are described. The emittance was measured as a function of both the laser beam spot size and laser wavelength at low currents. The data was used to infer the transverse thermal energy of the electrons photoemitted from GaAs for wavelengths between 514 and 840 nm. Near the bandgap the transverse energy is {approximately}34 meV, a factor of 3 lower than that of the beam from a typical thermionic electron gun. 8 refs., 2 figs.

  17. Decay properties of /sup 186/Pb and the lead alpha-decay rate anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Toth, K.S.; Ellis-Akovali, Y.A.; Bingham, C.R.; Moltz, D.M.; Carter, H.K.; Mlekodaj, R.L.; Spejewski, E.H.; Sousa, D.C.

    1984-01-01

    Alpha-decay transitions between ground states of doubly-even nuclei are taken to represent unhindered decays. Reduced widths for these s-wave transitions behave in a regular fashion as a function of both neutron and atomic number. They are largest for nuclei two or four particles beyond a closed shell (with sharp minima at the shell) and they then decrease as the next closure is approached. The s-wave widths for /sup 186/ /sup 188/ /sup 190/ /sup 192/Pb, however, have been reported to behave anomalously, i.e., they purportedly increase by a factor of 30 between /sup 186/Pb (N = 104) and /sup 192/Ob (N = 110) instead of decreasing as one nears N = 126. Theoretical calculations have not reproduced this unusual behavior. The (electron-capture (EC) + ..beta../sup +/) strengths were deduced from K x-ray intensities. A number of corrections are involved in such determinations. We undertook the investigation of the (EC + ..beta../sup +/) decay schemes of these neutron-deficient lead isotopes, in conjunction with studies of their ..cap alpha..-decay properties, to obtain more reliable ..cap alpha..-branching ratios. Herein we present new information on /sup 186/Pb and discuss the partial ..cap alpha.. half-lives for /sup 192/Pb, /sup 190/Pb, /sup 188/Pb, and /sup 186/Pb together with ..cap alpha..-decay rates for even-even nuclei with Z greater than or equal to 78.

  18. An extreme [OIII] emitter at $z=3.2$: a low metallicity Lyman continuum source

    CERN Document Server

    de Barros, S; Amorín, R; Castellano, M; Siana, B; Grazian, A; Suh, H; Balestra, I; Vignali, C; Verhamme, A; Zamorani, G; Mignoli, M; Hasinger, G; Comastri, A; Pentericci, L; Pérez-Montero, E; Fontana, A; Giavalisco, M; Gilli, R

    2016-01-01

    [Abridged] We investigate the physical properties of a Lyman continuum emitter candidate at $z=3.212$ with photometric coverage from $U$ to MIPS 24$\\mu$m band and VIMOS/VLT and MOSFIRE/Keck spectroscopy. Investigation of the UV spectrum confirms a direct spectroscopic detection of the Lyman continuum emission with $S/N>5$. Non-zero Ly$\\alpha$ flux at the systemic redshift and high Lyman-$\\alpha$ escape fraction suggest a low HI column density. The weak C and Si low-ionization absorption lines are also consistent with a low covering fraction along the line of sight. The [OIII]$\\lambda\\lambda4959,5007+\\mathrm{H}\\beta$ equivalent width is one of the largest reported for a galaxy at $z>3$ ($\\mathrm{EW}([\\mathrm{OIII}]\\lambda\\lambda4959,5007+\\mathrm{H}\\beta) \\simeq 1600\\AA$, rest-frame) and the NIR spectrum shows that this is mainly due to an extremely strong [OIII] emission. The large observed [OIII]/[OII] ratio ($>10$) and high ionization parameter are consistent with prediction from photoionization models in ca...

  19. Cooperative behavior of quantum dipole emitters coupled to a zero-index nanoscale waveguide

    CERN Document Server

    Sokhoyan, Ruzan

    2015-01-01

    We study cooperative behavior of quantum dipole emitters coupled to a rectangular waveguide with dielectric core and silver cladding. We investigate cooperative emission and inter-emitter entanglement generation phenomena for emitters whose resonant frequencies are near the frequency cutoff of the waveguide, where the waveguide effectively behaves as zero-index metamaterial. We show that coupling emitters to a zero-index waveguide allows one to relax the constraint on precision positioning of emitters for observing inter-emitter entanglement generation and extend the spatial scale at which the superradiance can be observed.

  20. Analysis on the positioning precision of CAPS

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    As a newly developed satellite positioning system, the Chinese Area Positioning System (CAPS) is a typical direct sequence spread spectrum ranging system like GPS. The positioning precision of such navigation signals depends on many factors, including the pseudo-code rate, the signal to noise ratio, the processing methods for tracking loops and so on. This paper describes the CAPS link budget, the solution approach for CAPS positioning, focusing on the autocorrelation function feature of C/A code signals. The CAPS signal measurement precision is studied by the software approach together with theoretical analysis of the range resolution. Because the conventional Delay Lock Loop (DLL) is vul- nerable to the impact of noise, a narrow correlator and multiple correlators as well as the corresponding discrimination methods of phases are proposed, which improves the robustness of DLL and the code-phase resolution of the measurement. The results show that the improvement of the DLL structure and the discrimination method are the most important way to improve the ranging resolution. Theoretical analysis and experimental results show that a CAPS receiver could reach a 20-m positioning precision by using three satellites with a supported height from an altimeter.

  1. Martian north polar cap summer water cycle

    CERN Document Server

    Brown, Adrian J; Becerra, Patricio; Byrne, Shane

    2016-01-01

    A key outstanding question in Martian science is 'are the polar caps gaining or losing mass and what are the implications for past, current and future climate?' To address this question, we use observations from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) of the north polar cap during late summer for multiple Martian years, to monitor the summertime water cycle in order to place quantitative limits on the amount of water ice deposited and sublimed in late summer. We establish here for the first time the summer cycle of water ice absorption band signatures on the north polar cap. We show that in a key region in the interior of the north polar cap, the absorption band depths grow until Ls=120, when they begin to shrink, until they are obscured at the end of summer by the north polar hood. This behavior is transferable over the entire north polar cap, where in late summer regions 'flip' from being net sublimating into net condensation mode. This transition or 'mode flip' happens earlier for ...

  2. Analysis on the positioning precision of CAPS

    Institute of Scientific and Technical Information of China (English)

    JI YuanFa; SUN XiYan

    2009-01-01

    As a newly developed satellite positioning system,the Chinese Area Positioning System (CAPS) Is a typical direct sequence spread spectrum ranging system like GPS.The positioning precision of such navigation signals depends on many factors,including the pseudo-code rate,the signal to noise ratio,the processing methods for tracking loops and so on.This paper describes the CAPS link budget,the solution approach for CAPS positioning,focusing on the autocorrelation function feature of C/A code signals.The CAPS signal measurement precision is studied by the software approach together with theoretical analysis of the range resolution.Because the conventional Delay Lock Loop (DLL) is vulnerable to the impact of noise,a narrow correlator and multiple correlatore as well as the corresponding discrimination methods of phases are proposed,which improves the robustness of DLL and the code-phase resolution of the measurement.The results show that the Improvement of the DLL structure and the discrimination method are the most important way to improve the ranging resolution.Theoretical analysis and experimental results show that a CAPS receiver could reach a 20-m positioning precision by using three satellites with a supported height from an altimeter.

  3. Radiation doses and risks from internal emitters

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, John [Health Protection Agency, Radiation Protection Division, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Day, Philip [School of Chemistry, University of Manchester, Manchester M13 9PL (United Kingdom)], E-mail: john.harrison@hpa.org.uk, E-mail: philip.day@manchester.ac.uk

    2008-06-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  4. Optical characterization of OLED emitter properties by radiation pattern analyses

    Energy Technology Data Exchange (ETDEWEB)

    Flaemmich, Michael

    2011-09-08

    Researches in both, academia and industry are investigating optical loss channels in OLED layered systems by means of optical simulation tools in order to derive promising concepts for a further enhancement of the overall device performance. Besides other factors, the prospects of success of such optimization strategies rely severely on the credibility of the optical input data. The present thesis provides a guideline to measure the active optical properties of OLED emitter materials in situ by radiation pattern analyses. Reliable and widely applicable methods are introduced to determine the internal electroluminescence spectrum, the profile of the emission zone, the dipole emitter orientation, and the internal luminescence quantum efficiency of emissive materials from the optical far field emission of OLEDs in electrical operation. The proposed characterization procedures are applied to sets of OLEDs containing both, fluorescent polymeric materials as well as phosphorescent small-molecular emitters, respectively. On the one hand, quite expected results are obtained. On the other hand, several novel and truly surprising results are found. Most importantly, this thesis contains the first report of a non-isotropic, mainly parallel emitter orientation in a phosphorescent small-molecular guest-host system (Ir(MDQ)2(acac) in a-NPD). Due to the latter result, emitter orientation based optimization of phosphorescent OLEDs seems to be within reach. Since parallel dipoles emit preferably into air, the utilization of smart emissive materials with advantageous molecular orientation is capable to boost the efficiency of phosphorescent OLEDs by 50%. Materials design, the influence of the matrix material and the substrate, as well as film deposition conditions are just a few parameters that need to be studied further in order to exploit the huge potential of the dipole emitter orientation in phosphorescent OLEDs.

  5. High-efficiency photonic crystal narrowband thermal emitters

    Science.gov (United States)

    Farfan, G. B.; Su, M. F.; Reda Taha, M. M.; El-Kady, I.

    2010-02-01

    Photonic crystals (PhC) are artificial structures fabricated with a periodicity in the dielectric function. This periodic electromagnetic potential results in creation of energy bandgaps where photon propagation is prohibited. PhC structures have promising use in thermal applications if optimized to operate at specific thermal emission spectrum. Here, novel utilization of optimized PhC's in thermal applications is presented. We demonstrate through numerical simulation the modification of the thermal emission spectrum by a metallic photonic crystal (PhC) to create high-efficiency multispectral thermal emitters. These emitters funnel radiation from a broad emission spectrum associated with a Plancklike distribution into a prescribed narrow emission band. A detailed quantitative evaluation of the spectral and power efficiencies of a PhC thermal emitter and its portability across infrared (IR) spectral bands are provided. We show an optimized tungsten PhC with a predominant narrow-band emission profile with an emitter efficiency that is more than double that of an ideal blackbody and ~65-75% more power-efficiency across the IR spectrum. We also report on using optimal three-dimensional Lincoln log photonic crystal (LL-PhC) emitters for thermophotovoltaic (TPV) generation as opposed to using a passive filtering approach to truncate the broadband thermal source emission to match the bandgap of a photovoltaic (PV) cell. The emitter performance is optimized for the 1-2μm PV band using different PhC materials, specifically copper, silver and gold. The use of the proposed PhC in TPV devices can produce significant energy savings not reported before. The optimal design of the PhC geometry is obtained by implementing a variety of optimization methods integrated with artificial intelligence (AI) algorithms.

  6. Nasute termite soldier frontal gland secretions. 1. Structure of Trinervi-2. beta. ,3. cap alpha. ,9. cap alpha. -triol 9-O acetate, a novel diterpene from Trinervitermes soldiers

    Energy Technology Data Exchange (ETDEWEB)

    Prestwich, G.D. (International Center of Insect Physiology and Ecology, Nairobi, Kenya); Tanis, S.P.; Springer, J.P.; Clardy, J.

    1976-09-15

    One of the major constituents, ''TG-2,'' of the soldier secretions of Trinervitermes gratiosus Sjostedt were studied by x-ray diffraction. The structure was determined to be a novel diterpene skeleton with a bridgehead double bond in an 11-membered ring. Bond angles and lengths were discussed, and a computer generated perspective drawing of the compound was presented. (DDA)

  7. Beam emittance reduction during operation of Indus-2

    Science.gov (United States)

    Fakhri, Ali Akbar; Kant, Pradeep; Ghodke, A. D.; Singh, Gurnam

    2015-11-01

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

  8. Beam emittance reduction during operation of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Fakhri, Ali Akbar, E-mail: fakhri@rrcat.gov.in; Kant, Pradeep; Ghodke, A. D.; Singh, Gurnam [Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India)

    2015-11-15

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

  9. Beam emittance reduction during operation of Indus-2

    International Nuclear Information System (INIS)

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed

  10. Beam emittance reduction during operation of Indus-2.

    Science.gov (United States)

    Fakhri, Ali Akbar; Kant, Pradeep; Ghodke, A D; Singh, Gurnam

    2015-11-01

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed. PMID:26628127

  11. Emittances Studies at the Fermilab/NICADD Photoinjector Laboratory

    CERN Document Server

    Tikhoplav, Rodion; Melissinos, A C; Regis-Guy Piot, Philippe

    2005-01-01

    The Fermilab/NICADD photoinjector incorporates an L-band rf-gun capable of generating 1-10 nC bunches. The bunches are then accelerated to 16 MeV with a TESLA superconducting cavity. In the present paper we present parametric studies of transverse emittances and energy spread for a various operating points of the electron source (RF-gun E-field, laser length and spot size, and solenoid settings). We especially study the impact, on transverse emittance, of Gaussian and Plateau temporal distribution of the photocathode drive-laser.

  12. Thermal emittance and response time of a cesium antimonide photocathode

    Science.gov (United States)

    Cultrera, Luca; Bazarov, Ivan; Bartnik, Adam; Dunham, Bruce; Karkare, Siddharth; Merluzzi, Richard; Nichols, Matthew

    2011-10-01

    Measurements of the intrinsic emittance and response time of a Cs3Sb photocathode are presented. The emittance is obtained with a solenoid scan technique using a high voltage dc photoemission gun. Photoemission response time is evaluated using a RF deflecting cavity synchronized to a picosecond laser pulse train. We find that Cs3Sb has both small mean transverse energy, 160 ± 10 meV at 532 nm laser wavelength, and a prompt response time (below the resolution of our measurement) making it a suitable material for high brightness electron photoinjectors.

  13. Efficient Terahertz Photoconductive Emitters with Improved Electrode Structures

    Institute of Scientific and Technical Information of China (English)

    Ying-Xin Wang; Yi-Jie Niu; Wei Cheng; Zhi-Qiang Li; Zi-Ran Zhao

    2014-01-01

    We present the design, fabrication, and characterization of two new types of terahertz photoconductive emitters. One has an asymmetric four-contact electrode structure and the other has an arc-shaped electrode structure, which are all modified from a traditional strip line antenna. Numerical simulations and real experiments confirm the good performance of the proposed antennas. An amplitude increase of about 40% is experimentally observed for the terahertz signals generated from the new structures. The special electrode structure and its induced local bias field enhancement are responsible for this radiation efficiency improvement. Our work demonstrates the feasibility of developing highly efficient terahertz photoconductive emitters by optimizing the electrode structure.

  14. Ultra-Sensitivity Glucose Sensor Based on Field Emitters

    Directory of Open Access Journals (Sweden)

    Song Yinglin

    2009-01-01

    Full Text Available Abstract A new glucose sensor based on field emitter of ZnO nanorod arrays (ZNA was fabricated. This new type of ZNA field emitter-based sensor shows high sensitivity with experimental limit of detection of 1 nM glucose solution and a detection range from 1 nM to 50 μM in air at room temperature, which is lower than that of glucose sensors based on surface plasmon resonance spectroscopy, fluorescence signal transmission, and electrochemical signal transduction. The new glucose sensor provides a key technique for promising consuming application in biological system for detecting low levels of glucose on single cells or bacterial cultures.

  15. Emittance Measurements at the Langley Chemical Physics Laboratory

    Science.gov (United States)

    Lewis, B. W.

    1960-01-01

    Total hemispherical emittance measurements are made routinely for materials which may be heated by electrical resistance methods over the temperature range of 600 degrees to 2,000 F by using a black-body reference method. This employs a conical black body and a thermopile detector with a calcium fluoride lens. Emittance is obtained by measuring the radiant flux from the specimen strip and comparing it with the flux from an equal area of the black-body cone at the same temperature. The temperature measurements are made by use of thermocouples. It is planned to extend the temperature range of this type of measurement to temperatures above 2,000 F. Another technique has been investigated for measuring emittance of materials not amenable to electrical heating or thermocouple attachment. This method uses a black-body-cavity furnace similar to that used in reference 5 to measure emittance of transparent materials such as glass. The method employs a heated black-body cavity in which the semicircular specimen is allowed to come to the equilibrium temperature of the cavity and then is rotated in front of a water-cooled viewing port where a sensitive thermistor detector alternately views the specimen surface and the black-body cavity. The ratio of the two readings gives the specimen emittance directly, for the temperature of the black body. The detector output is recorded on a fast Brown self-balancing potentiometer. The furnace is provided with a water-cooled blackened shutter which may be inserted behind the specimen to eliminate any transmitted black-body radiation if the specimen is transparent. This apparatus is capable of measuring total normal emittance over the temperature range of 1,000 degrees to 2,000 F. Preliminary data for boron nitride specimens of two thicknesses are shown where total normal emittance is plotted against temperature for two experimental conditions: (1) black-body radiation incident on the back of the specimen and (2) no black-body radiation

  16. Observation of negative differential transconductance in tunneling emitter bipolar transistors

    Science.gov (United States)

    van Veenhuizen, Marc J.; Locatelli, Nicolas; Moodera, Jagadeesh; Chang, Joonyeon

    2009-08-01

    We report on measurement of negative differential transconductance (NDTC) of iron (Fe)/magnesium-oxide (MgO)/silicon tunneling emitter NPN bipolar transistors. Device simulations reveal that the NDTC is a consequence of an inversion layer at the tunneling-oxide/P-silicon interface for low base voltages. Electrons travel laterally through the inversion layer into the base and give rise to an increase in collector current. The NDTC results from the recombination of those electrons at the interface between emitter and base contact which is dependent on the base voltage. For larger base voltages, the inversion layer disappears marking the onset of normal bipolar transistor behavior.

  17. Ultra-low emittance X-band photocathode RF gun

    Institute of Scientific and Technical Information of China (English)

    TANG Chuan-Xiang; LIU Xiao-Han

    2009-01-01

    In this paper,we present the simulation results of a 1.6 cell X-band photocathode RF gun for ultra-low emittance electron beams.It will work at 9.3 GHz.The emittance,bunch length,electron energy and energy spread at the gun exit are optimized at bunch charge of 1pC using PARMELA.Electron bunches type coupler is adopted in this gun and an initial simulation by MAFIA is also given in this paper.

  18. Carbon Nanotube Electron Emitter for X-ray Imaging

    Directory of Open Access Journals (Sweden)

    Jung Su Kang

    2012-11-01

    Full Text Available The carbon nanotube field emitter array was grown on silicon substrate through a resist-assisted patterning (RAP process. The shape of the carbon nanotube array is elliptical with 2.0 × 0.5 mm2 for an isotropic focal spot size at anode target. The field emission properties with triode electrodes show a gate turn-on field of 3 V/µm at an anode emission current of 0.1 mA. The author demonstrated the X-ray source with triode electrode structure utilizing the carbon nanotube emitter, and the transmitted X-ray image was of high resolution.

  19. The Deepest Spectrum in the Universe? Line Emission from Lyman-alpha Clouds at z 3

    Science.gov (United States)

    Bunker, Andrew J.; Rauch, M.; Haehnelt, M.; Becker, G.; Marleau, F.; Graham, J.; Research, European; Inter-Galactic Medium, Training Network on the

    2007-12-01

    We present the results of an extremely deep long-slit optical spectroscopic search for low-luminosity Lyman-alpha emitters. Over several years we have accumulated 150-hours integration on a single field with 8-10m telescopes (VLT/FORS2, Gemini/GMOS and Keck/LRIS) at a spectral resolution of 300km/s. This is the deepest spectrum ever obtained - our 1 sigma sensitivity to line emission in a 1 arcsec2 aperture is 1019erg/cm2/s. We have significant detections of 30 emission line objects, which are most likely Lyman-alpha emitters at 2.7emitters are significantly spatially extended (with median size 4arcsec, 30kpc) and could plausibly be the host population of the high column density Lyman-alpha absorption clouds seen in QSO spectra (the Damped Lyman-alpha Systems and the Lyman-Limit Systems).

  20. Capping complex formation at the slow-growing end of the actin filament.

    Science.gov (United States)

    Kostyukova, A S

    2008-12-01

    Actin filaments are polar; their barbed (fast-growing) and pointed (slow-growing) ends differ in structure and dynamic properties. The slow-growing end is regulated by tropomodulins, a family of capping proteins that require tropomyosins for optimal function. There are four tropomodulin isoforms; their distributions vary depending on tissue type and change during development. The C-terminal half of tropomodulin contains one compact domain represented by alternating alpha-helices and beta-structures. The tropomyosin-independent actin-capping site is located at the C-terminus. The N-terminal half has no regular structure; however, it contains a tropomyosin-dependent actin-capping site and two tropomyosin-binding sites. One tropomodulin molecule can bind two tropomyosin molecules. Effectiveness of tropomodulin binding to tropomyosin depends on the tropomyosin isoform. Regulation of tropomodulin binding at the pointed end as well as capping effectiveness in the presence of specific tropomyosins may affect formation of local cytoskeleton and dynamics of actin filaments in cells. PMID:19216712

  1. Review of alpha_s determinations

    OpenAIRE

    Pich, Antonio

    2013-01-01

    The present knowledge on the strong coupling is briefly summarized. The most precise determinations of alpha_s, at different energies, are reviewed and compared at the Z mass scale, using the predicted QCD running. The impressive agreement achieved between experimental measurements and theoretical predictions constitutes a beautiful and very significant test of Asymptotic Freedom, establishing QCD as the fundamental theory of the strong interaction. The world average value of the strong coupl...

  2. Recent $\\alpha$ decay half-lives and analytic expression predictions including superheavy nuclei

    CERN Document Server

    Royer, G

    2008-01-01

    New recent experimental $\\alpha$ decay half-lives have been compared with the results obtained from previously proposed formulas depending only on the mass and charge numbers of the $\\alpha$ emitter and the Q$\\alpha$ value. For the heaviest nuclei they are also compared with calculations using the Density-Dependent M3Y (DDM3Y) effective interaction and the Viola-Seaborg-Sobiczewski (VSS) formulas. The correct agreement allows us to make predictions for the $\\alpha$ decay half-lives of other still unknown superheavy nuclei from these analytic formulas using the extrapolated Q$\\alpha$ of G. Audi, A. H. Wapstra, and C. Thibault [Nucl. Phys. A729, 337 (2003)].

  3. Can we trust corporates GHG inventories? An investigation among Canada's large final emitters

    International Nuclear Information System (INIS)

    In the public sphere and the literature on climate strategies, the measurability of corporate GHG emissions tends to be taken for granted, and few empirical studies have examined the reliability of such data. The present case study, which was conducted among 10 Canadian companies considered as large final emitters and three auditing firms, focuses on the factors which could affect the perceived credibility of GHG inventories and the strategic implications of these. The qualitative, inductive study allows identifying three main factors which affect trust in business inventories: technical issues and complexity of GHG measurements, lack of transparency on the part of the companies and unreliability of verification mechanisms. The study also makes it possible to evaluate the implications of uncertainties concerning GHG inventories which are of strategic importance for companies and policy makers. While the reliability of GHG measurement is taken for granted at the political level, uncertainties in this area can in fact have a huge impact on the establishment of the cap and trade system. The study also contributes to the literature on carbon accounting by shedding light on underexplored ethical issues, including the lack of independence of auditors and its implications. - Highlights: • The complexity of GHG emission measurement is underestimated in the public sphère. • The data disclosed by companies to the different stakeholders lack transparency. • The auditors' lack of competence and independence undermine the credibility of audit reports

  4. Seismic explosion sources on an ice cap

    DEFF Research Database (Denmark)

    Shulgin, Alexey; Thybo, Hans

    2015-01-01

    Controlled source seismic investigation of crustal structure below ice covers is an emerging technique. We have recently conducted an explosive refraction/wide-angle reflection seismic experiment on the ice cap in east-central Greenland. The data-quality is high for all shot points and a full...... crustal model can be modelled. A crucial challenge for applying the technique is to control the sources. Here, we present data that describe the efficiency of explosive sources in the ice cover. Analysis of the data shows, that the ice cap traps a significant amount of energy, which is observed...... as a strong ice wave. The ice cap leads to low transmission of energy into the crust such that charges need be larger than in conventional onshore experiments to obtain reliable seismic signals. The strong reflection coefficient at the base of the ice generates strong multiples which may mask for secondary...

  5. Martian north polar cap summer water cycle

    Science.gov (United States)

    Brown, Adrian J.; Calvin, Wendy M.; Becerra, Patricio; Byrne, Shane

    2016-10-01

    A key outstanding question in Martian science is "are the polar caps gaining or losing mass and what are the implications for past, current and future climate?" To address this question, we use observations from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) of the north polar cap during late summer for multiple Martian years, to monitor the summertime water cycle in order to place quantitative limits on the amount of water ice deposited and sublimed in late summer. We establish here for the first time the summer cycle of water ice absorption band signatures on the north polar cap. We show that in a key region in the interior of the north polar cap, the absorption band depths grow until Ls = 120, when they begin to shrink, until they are obscured at the end of summer by the north polar hood. This behavior is transferable over the entire north polar cap, where in late summer regions 'flip' from being net sublimating into net condensation mode. This transition or 'mode flip' happens earlier for regions closer to the pole, and later for regions close to the periphery of the cap. The observations and calculations presented herein estimate that on average a water ice layer ∼70 microns thick is deposited during the Ls = 135-164 period. This is far larger than the results of deposition on the south pole during summer, where an average layer 0.6-6 microns deep has been estimated by Brown et al. (2014) Earth Planet. Sci. Lett., 406, 102-109.

  6. Pharmacy benefit caps and the chronically ill.

    Science.gov (United States)

    Joyce, Geoffrey F; Goldman, Dana P; Karaca-Mandic, Pinar; Zheng, Yuhui

    2007-01-01

    In this paper we examine medication use among retirees with employer-sponsored drug coverage both with and without annual benefit limits. We find that pharmacy benefit caps are associated with higher rates of medication discontinuation across the most common therapeutic classes and that only a minority of those who discontinue use reinitiate therapy once coverage resumes. Plan members who reach their cap are more likely than others to switch plans and increase their rate of generic use; however, in most cases, the shift is temporary. Given the similarities between these plans and Part D, we make some inferences about reforms for Medicare.

  7. Assembling the CMS yoke end-caps

    CERN Multimedia

    Laurent Guiraud

    2001-01-01

    A crane is used to piece together one of the end-caps that will provide the path for magnetic flux return on the CMS experiment. A total of six end-cap discs will be assembled before being positioned on the barrel yoke to complete the huge 12 500 tonne cylinder yoke. The magnetic field produced will be greater than any other solenoid created to date at 4 T, 100 000 times greater than the Earth's natural magnetic field, and will store enough energy to melt 18 tonnes of gold.

  8. Design and implementation of the CAPS receiver

    Institute of Scientific and Technical Information of China (English)

    HU YongHui; HUA Yu; HOU Lei; WEI JingFa; WU JianFeng

    2009-01-01

    In this paper,baaed on analyses of the Chinese Area Positioning System (CAPS) satellite (GEO satellite) resources and signal properties,the signal power at the port of the receiver antenna is estimated,and the implementation projects are presented for a switching band C to band L CAPS C/A code receiver integrated with GPS receiver suite and for a CAPS dual frequency P code receiver.A microstrip receiving antenna is designed with high sensitivity and wide beam orientation,the RF front end of the C/A code and P code receivers,and a processor is designed for the navigation baseband.A single frequency CAPS C/A code receiver and a CAPS dual frequency P code receiver are built at the same time.A software process flow is provided,and research on relatively key techniques is also conducted,such as signal searching,code loop and carrier loop algorithms,a height assistant algorithm,a dual frequency difference speed measurement technique,a speed measurement technique using a single frequency source with frequency assistance,and a CAPS time correcting algorithm,according to the design frame of the receiver hardware.Research results show that the static plane positioning accuracy of the CAPS C/A code receiver is 20.5-24.6 m,height accuracy is 1.2-12.8 m,speed measurement accuracy is 0.13-0.3 m/s,dynamic plane positioning accuracy is 24.4 m,height accuracy is 3.0 m,and speed measurement accuracy is 0.24 m/s.In the case of C/A code,the timing accuracy is 200 ha,and it is also shown that the positioning accuracy of the CAPS precise code receiver (1σ) is 5 m from south to north,and 0.8 m from east to west.Finally,research on positioning accuracy is also conducted.

  9. Report of a Technical Meeting on ''Alpha emitting radionuclides and radiopharmaceuticals for therapy''

    International Nuclear Information System (INIS)

    Considering the high potential of α-emitters for future development of radionuclide therapy, the International Atomic Energy Agency (IAEA) organized a Technical Meeting on ‘Alpha Emitting Radionuclides and Radiopharmaceuticals for Therapy’, from June 24 to 28, 2013, at IAEA Headquarters in Vienna with the purpose of gathering eminent Experts in the field and discuss with them the status and future perspectives of the field. Sixteen Experts and two External Observers from ten different countries, and four IAEA Technical Officers attended this meeting. Outstanding lectures have been presented covering all relevant aspects of α-therapy, which were followed by extensive discussions and analysis. Selected arguments encompassed production methods and availability of alpha-emitting radionuclides, labelling chemistry of alpha-emittting radioelements, design and development of target-specific radiopharmaceuticals, physical principles of alpha-particle dosimetry and advanced dosimetric models, biological effects of alpha radiation at the cellular level, on-going preclinical and clinical studies with new radiopharmaceuticals, results of clinical trials on the use of radium-223 chloride solutions for the treatment of metastatic bone cancer. The broad scientific background of invited components of the Experts’ panel conferred a strong interdisciplinary trait to the overall discussion and stimulated a critical analysis of this emerging unexplored field. Results of this comprehensive overview on alpha therapy, including recommendations to the Agency on suitable initiatives that may help to promote and spread the knowledge to Members States on this emerging therapeutic modality, are summarized in the present Report

  10. The effects of emitter-tied field plates on lateral PNP ionizing radiation response

    Energy Technology Data Exchange (ETDEWEB)

    Barnaby, H.J.; Schrimpf, R.D.; Cirba, C.R. [Vanderbilt Univ., Nashville, TN (United States); Pease, R.L. [RLP Research, Inc., Albuquerque, NM (United States); Fleetwood, D.M. [Sandia National Labs., Albuquerque, NM (United States); Kosier, S.L. [VTC Inc., Bloomington, MN (United States)

    1998-03-01

    Radiation response comparisons of lateral PNP bipolar technologies reveal that device hardening may be achieved by extending the emitter contact over the active base. The emitter-tied field plate suppresses recombination of carriers with interface traps.

  11. Analysis of Urine for Pure Beta Emitters: Methods and Application

    DEFF Research Database (Denmark)

    Hou, Xiaolin

    2011-01-01

    by combustion to separate tritiated water from organically-bound tritium. Inorganic C-14 from organically-bound C-14, the separated tritium and C-14 were measured using liquid scintillation counting. Iodine-129, a long-lived beta emitter, is normally released to the atmosphere during the operation of nuclear...

  12. Calculation Of Extraction Optics For Ion System With Plazma Emitter

    CERN Document Server

    Frolov, B A

    2004-01-01

    The 2-D code for simulating of ion optics system of positive ion extraction from a plasma source is described. Example calculation of 100 kV optics for the extraction ion IHEP gun is presented. The trajectories of particles and emittance plots are resulted. The aberrations influ-ence strongly on ion optics for considered geometry.

  13. Magnetized Plasma Experiments Using Thermionic- Thermoelectronic Plasma Emitter

    Science.gov (United States)

    Kawamori, Eiichirou; Cheng, C. Z.; Fujikawa, Nobuko; Lee, Jyun-Yi; Peng, Albert

    2008-11-01

    We are developing a magnetic mirror device, which is the first magnetized plasma device in Taiwan, to explore basic plasma sciences relevant to fusion, space and astrophysical plasmas. Our research subjects include electromagnetically induced transparency (EIT), Alfven wave physics, and plasma turbulence. A large diameter (> 200 mm) plasma emitter1, which utilizes thermionic- thermoelectronic emission from a mixture of LaB6 (Lanthanum-hexaboride) and beta-eucryptite (lithium type aluminosylicate) powders, is employed as a plasma source because of its production ability of fully ionized plasma and controllability of plasma emission rate. The plasma emitter has been installed recently and investigation of its characteristics will be started. The employment of beta-eucryptite in plasma emitter is the first experimental test because such investigation of beta-eucryptite has previously been used only for Li+-ion source2. Our plan for magnetized plasma experiments and results of the plasma emitter investigation will be presented. 1. K. Saeki, S. Iizuka, N. Sato, and Y. Hatta, Appl. Phys. Lett., 37, 1980, pp. 37-38. 2. M. Ueda, R. R. Silva, R. M. Oliveira, H. Iguchi, J. Fujita and K. Kadota, J. Phys. D: Appl. Phys. 30 1997, pp. 2711--2716.

  14. Application of positron emitters to studies on plants

    Energy Technology Data Exchange (ETDEWEB)

    Ishioka, N.S.; Matsuoka, H. [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Sekine, T. [and others

    1998-10-01

    A newly developed positron emitting tracer imaging system enables us to study dynamically the physiological function of plants, although this system covers, at present, a limited area in a plant. Production of the positron emitters {sup 11}C, {sup 13}N, {sup 18}F and {sup 48}V for this application, using an AVF cyclotron, is described. (author)

  15. Auger Emitter Based Radiotherapy- A Possible New Treatment for Cancer

    DEFF Research Database (Denmark)

    Fredericia, Pil; Groesser, Torsten; Severin, Gregory;

    2014-01-01

    damage produced by Low-LET radiation used in current radiotherapy (2-3) Considerable efforts have been made in the past twenty years to develop Auger emitter-based radiotherapy However, previous studies lack precise measurement of RBE, which is the fundamental factor defining the relationship between...

  16. Achieving ultra-high temperatures with a resistive emitter array

    Science.gov (United States)

    Danielson, Tom; Franks, Greg; Holmes, Nicholas; LaVeigne, Joe; Matis, Greg; McHugh, Steve; Norton, Dennis; Vengel, Tony; Lannon, John; Goodwin, Scott

    2016-05-01

    The rapid development of very-large format infrared detector arrays has challenged the IR scene projector community to also develop larger-format infrared emitter arrays to support the testing of systems incorporating these detectors. In addition to larger formats, many scene projector users require much higher simulated temperatures than can be generated with current technology in order to fully evaluate the performance of their systems and associated processing algorithms. Under the Ultra High Temperature (UHT) development program, Santa Barbara Infrared Inc. (SBIR) is developing a new infrared scene projector architecture capable of producing both very large format (>1024 x 1024) resistive emitter arrays and improved emitter pixel technology capable of simulating very high apparent temperatures. During earlier phases of the program, SBIR demonstrated materials with MWIR apparent temperatures in excess of 1400 K. New emitter materials have subsequently been selected to produce pixels that achieve even higher apparent temperatures. Test results from pixels fabricated using the new material set will be presented and discussed. A 'scalable' Read In Integrated Circuit (RIIC) is also being developed under the same UHT program to drive the high temperature pixels. This RIIC will utilize through-silicon via (TSV) and Quilt Packaging (QP) technologies to allow seamless tiling of multiple chips to fabricate very large arrays, and thus overcome the yield limitations inherent in large-scale integrated circuits. Results of design verification testing of the completed RIIC will be presented and discussed.

  17. Emittance control and RF bunch compression in the NSRRC photoinjector

    Science.gov (United States)

    Lau, W. K.; Hung, S. B.; Lee, A. P.; Chou, C. S.; Huang, N. Y.

    2011-05-01

    The high-brightness photoinjector being constructed at the National Synchrotron Radiation Research Center is for testing new accelerator and light-source concepts. It is the so-called split photoinjector configuration in which a short solenoid magnet is used for emittance compensation. The UV-drive laser pulses are also shaped to produce uniform cylindrical bunches for further reduction of beam emittance. However, limited by the available power from our microwave power system, the nominal accelerating gradient in the S-band booster linac is set at 18 MV/m. A simulation study with PARMELA shows that the linac operating at this gradient fails to freeze the electron beam emittance at low value. A background solenoid magnetic field is applied for beam emittance control in the linac during acceleration. A satisfactory result that meets our preliminary goal has been achieved with the solenoid magnetic field strength at 0.1 T. RF bunch compression as a means to achieve the required beam brightness for high-gain free-electron laser experiments is also examined. The reduction of bunch length to a few hundred femtoseconds can be obtained.

  18. Emittance control and RF bunch compression in the NSRRC photoinjector

    International Nuclear Information System (INIS)

    The high-brightness photoinjector being constructed at the National Synchrotron Radiation Research Center is for testing new accelerator and light-source concepts. It is the so-called split photoinjector configuration in which a short solenoid magnet is used for emittance compensation. The UV-drive laser pulses are also shaped to produce uniform cylindrical bunches for further reduction of beam emittance. However, limited by the available power from our microwave power system, the nominal accelerating gradient in the S-band booster linac is set at 18 MV/m. A simulation study with PARMELA shows that the linac operating at this gradient fails to freeze the electron beam emittance at low value. A background solenoid magnetic field is applied for beam emittance control in the linac during acceleration. A satisfactory result that meets our preliminary goal has been achieved with the solenoid magnetic field strength at 0.1 T. RF bunch compression as a means to achieve the required beam brightness for high-gain free-electron laser experiments is also examined. The reduction of bunch length to a few hundred femtoseconds can be obtained.

  19. Scanning Emitter Lifetime Imaging Microscopy for Spontaneous Emission Control

    DEFF Research Database (Denmark)

    Frimmer, Martin; Chen, Yuntian; Koenderink, A. Femius

    2011-01-01

    We report an experimental technique to map and exploit the local density of optical states of arbitrary planar nanophotonic structures. The method relies on positioning a spontaneous emitter attached to a scanning probe deterministically and reversibly with respect to its photonic environment whi...

  20. Measurement of Transverse Emittance in the Fermilab Booster.

    Science.gov (United States)

    Graves, William Sproull

    A new beam profile monitor has been built and installed in the Fermilab Booster synchrotron. It nondestructively measures the beam's vertical density distribution on a fast turn-by-turn basis. This enables one to measure the beam's transverse emittance and to observe emittance growth as it occurs. For high intensities (>2 times 10^{12 } protons), the normalized 95% emittance was observed to grow from 6pi mm-mrad at injection to 16pi mm-mrad at extraction. The initial (beam losses are shown to be caused by the space charge tune shift onto integer and 1/2 integer resonance lines. The growth near injection accounts for approximately 40% of the observed emittance increase throughout the acceleration cycle. The remaining 60% is due to two factors: slow linear growth due to betatron-motion driven by noise in the rf system; and faster growth after the transition energy that is caused by coupling of the longitudinal beam motion into the transverse planes.

  1. Transverse beam emittance measurement using quadrupole variation at KIRAMS-430

    Science.gov (United States)

    An, Dong Hyun; Hahn, Garam; Park, Chawon

    2015-02-01

    In order to produce a 430 MeV/u carbon ion (12 C 6+) beam for medical therapy, the Korea Institute of Radiological & Medical Sciences (KIRAMS) has carried out the development of a superconducting isochronous cyclotron, the KIRAMS-430. At the extraction of the cyclotron, an Energy Selection System (ESS) is located to modulate the fixed beam energy and to drive the ion beam through High Energy Beam Transport (HEBT) into the treatment room. The beam emittance at the ion beamline is to be measured to provide information on designing a beam with high quality. The well-known quadrupole variation method was used to determine the feasibility of measuring the transverse beam emittance. The beam size measured at the beam profile monitor (BPM) is to be utilized and the transformation of beam by transfer matrix is to be applied being taken under various transport condition of varying quadrupole magnetic strength. Two different methods where beam optics are based on the linear matrix formalism and particle tracking with a 3-D magnetic field distribution obtained by using OPERA3D TOSCA, are applied to transport the beam. The fittings for the transformation parameters are used to estimate the transverse emittance and the twiss parameters at the entrance of the quadrupole in the ESS. Including several systematic studies, we conclude that within the uncertainty the estimated emittances are consistent with the ones calculated by using Monte Carlo simulations.

  2. Selective-emitter crystalline silicon solar cells using phosphorus paste

    International Nuclear Information System (INIS)

    Selective-emitter structures have been studied to improve the conversion efficiency of crystalline silicon solar cells. However, such structures require additional complicated processes and incur extra cost. In this work, we used phosphorus paste (P-paste) to form a heavily-doped region beneath the grid and POCl3 to create a shallow emitter area. This method should be convenient to use in the solar-cell industry because it requires only additional P paste printing, compared to the case of homogeneous solar cells. Diffusion parameters including the temperature, diffusion time, and ambient gases were optimized. We observed that the spreading of the P paste was affected by the pyramidal size of the textured wafer due to the low viscosity of the P paste. The pyramidal height of the textured silicon surface was optimized at 3 μm to counterbalance the surface reflectance and the spreading of the P paste. The short-circuit current density of the completed selective emitter solar cell was increased, and an improvement of blue response in the internal quantum efficiency was seen while contact properties such as the fill factor deteriorated due to the spreading of the P paste and the thin emitter on top of the pyramid of the textured silicon surface. Double printing of the P paste was applied to solve this contact problem; a fill factor improvement of 2.4% was obtained.

  3. Selective-emitter crystalline silicon solar cells using phosphorus paste

    Science.gov (United States)

    Jeong, Kyung Taek; Kang, Min Gu; Song, Hee-eun

    2014-11-01

    Selective-emitter structures have been studied to improve the conversion efficiency of crystalline silicon solar cells. However, such structures require additional complicated processes and incur extra cost. In this work, we used phosphorus paste (P-paste) to form a heavily-doped region beneath the grid and POCl3 to create a shallow emitter area. This method should be convenient to use in the solar-cell industry because it requires only additional P paste printing, compared to the case of homogeneous solar cells. Diffusion parameters including the temperature, diffusion time, and ambient gases were optimized. We observed that the spreading of the P paste was affected by the pyramidal size of the textured wafer due to the low viscosity of the P paste. The pyramidal height of the textured silicon surface was optimized at 3 μm to counterbalance the surface reflectance and the spreading of the P paste. The short-circuit current density of the completed selective emitter solar cell was increased, and an improvement of blue response in the internal quantum efficiency was seen while contact properties such as the fill factor deteriorated due to the spreading of the P paste and the thin emitter on top of the pyramid of the textured silicon surface. Double printing of the P paste was applied to solve this contact problem; a fill factor improvement of 2.4% was obtained.

  4. Development of High Intensity Beam Emittance Measurement Unit

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Three sets of High Intensity Beam Emittance Measurement Units (HIBEMUs) are being developed at Peking University. They are HIBEMU-2 (slit-wire type, one direction), HIBEMU-3 (Allison scanner type, one direction) and HIBEMU-4 (slit-wire type, two directions). For HIBEMU-2 and HIBEMU-3, more recent work has been done on software redesign in order to measure beam emittance and to draw phase diagram more efficiently and precisely. Software for control and data processing of them were developed in Labveiw environment, trying to improve calculation rationality and to offer user-friendly interface. Mechanical modification was also done for HIBEMU-3, mainly concentrating on the protection of Faraday cups from being overheated by the high intensity beam and also from interference of secondary electrons. This paper will also cover the mechanical structure as well as the software development of HIBEMU-4, which is a two-direction emittance scanner newly designed and manufactured for the high energy beam transport (HEBT) of Peking University Neutron Imaging FaciliTY (PKUNIFTY). At the end of this paper, comparison and analysis of the three HIBEMUs are given to draw forth better design of the future emittance measurement facility.

  5. Limits to Electron Beam Emittance from Stochastic Coulomb Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Coleman-Smith, Christopher; Padmore, Howard A.; Wan, Weishi

    2008-08-22

    Dense electron beams can now be generated on an ultrafast timescale using laser driven photo-cathodes and these are used for a range of applications from ultrafast electron defraction to free electron lasers. Here we determine a lower bound to the emittance of an electron beam limited by fundamental stochastic Coulomb interactions.

  6. Emitter/absorber interface of CdTe solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tao [Physics Department, Colorado State University, Fort Collins, Colorado 80523, USA; Kanevce, Ana [National Renewable Energy Laboratory, Golden, Colorado 80401, USA; Sites, James R. [Physics Department, Colorado State University, Fort Collins, Colorado 80523, USA

    2016-06-17

    The performance of CdTe solar cells can be very sensitive to their emitter/absorber interfaces, especially for high-efficiency cells with improved bulk properties. When interface defect states are located at efficient recombination energies, performance losses from acceptor-type interface defects can be significant. Numerical simulations show that the emitter/absorber band alignment, the emitter doping and thickness, and the defect properties of the interface (i.e. defect density, defect type, and defect energy) can all play significant roles in the interface recombination. In particular, a type I heterojunction with small conduction-band offset (0.1 eV /= 0.4 eV), however, can impede electron transport and lead to a reduction of photocurrent and fill-factor. In contrast to the spike, a 'cliff' (.delta..EC < 0 eV) is likely to allow many holes in the vicinity of the interface, which will assist interface recombination and result in a reduced open-circuit voltage. In addition, a thin and highly-doped emitter can invert the absorber, form a large hole barrier, and decrease device performance losses due to high interface defect density. CdS is the most common emitter material used in CdTe solar cells, but the CdS/CdTe interface is in the cliff category and is not favorable from the band-offset perspective. Other n-type emitter choices, such as (Mg,Zn)O, Cd(S,O), or (Cd,Mg)Te, can be tuned by varying the elemental ratio for an optimal positive value of ..delta..EC. These materials are predicted

  7. HYDRAULIC CHARACTERIZATIONS OF TORTUOUS FLOW IN PATH DRIP IRRIGATION EMITTER

    Institute of Scientific and Technical Information of China (English)

    LI Yun-kai; YANG Pei-ling; REN Shu-mei; XU Ting-wu

    2006-01-01

    At present, the tortuous emitter has the most advanced performances in drip irrigation. But the theories and methods for designing its flow path have been strictly confidential and the researches on the function of practical guidance have seldom been published. Seven types of most representative tortuous emitting-pipes currently used in agricultural irrigation regions of China were chosen for investigating the geometric parameters of the flow path by means of combining high-precision microscope and AutoCAD technology. By the measurement platform developed by the authors for hydraulic performances of emitters, the free discharge rates from the 7 types of emitters were measured at 9 pressure levels of 1.5 m, 3.0 m, 5.0 m, 7.0 m, 9.0 m, 10.0 m, 11.0 m, 13.0 m and 15.0 m. Then the discharge-pressure relationship, manufacturing variation coefficient, average velocity on the cross-section of flow path and the critical Reynolds number for the flow regime transformation within the paths were analyzed in detail. The results show that both pressure-ascending work pattern and pressure-descending work pattern have some impacts on the discharge rates of tortuous emitters, but the impact level is not significant. The target pressure could be approached by repetitive applications of the two work patterns during pressure regulation. The operation under low pressures has some impacts on the hydraulic performances of emitters, but the impact level is also not significant. The classical model of the discharge-pressure relationship is suitable for the pressure range of 1.5 m -15.0 m. The Reynolds number for fluids within the 7 types of tortuous emitters ranges from =105 to =930. The critical Reynolds number for the flow regime transformation is smaller than that for the routine dimension flow path. The variation coefficient of emitter discharge rates is slightly fluctuating around a certain value within the whole pressure range.

  8. New ALPHA-2 magnet

    CERN Multimedia

    Anaïs Schaeffer

    2012-01-01

    On 21 June, members of the ALPHA collaboration celebrated the handover of the first solenoid designed for the ALPHA-2 experiment. The magnet has since been successfully installed and is working well.   Khalid Mansoor, Sumera Yamin and Jeffrey Hangst in front of the new ALPHA-2 solenoid. “This was the first of three identical solenoids that will be installed between now and September, as the rest of the ALPHA-2 device is installed and commissioned,” explains ALPHA spokesperson Jeffrey Hangst. “These magnets are designed to allow us to transfer particles - antiprotons, electrons and positrons - between various parts of the new ALPHA-2 device by controlling the transverse size of the particle bunch that is being transferred.” Sumera Yamin and Khalid Mansoor, two Pakistani scientists from the National Centre for Physics in Islamabad, came to CERN in February specifically to design and manufacture these magnets. “We had the chance to work on act...

  9. Nonlocal effects: relevance for the spontaneous emission rates of quantum emitters coupled to plasmonic structures

    CERN Document Server

    Filter, Robert; Toscano, Giuseppe; Lederer, Falk; Rockstuhl, Carsten

    2014-01-01

    The spontaneous emission rate of dipole emitters close to plasmonic dimers are theoretically studied within a nonlocal hydrodynamic model. A nonlocal model has to be used since quantum emitters in the immediate environment of a metallic nanoparticle probe its electronic structure. Compared to local calculations, the emission rate is significantly reduced. The influence is mostly pronounced if the emitter is located close to sharp edges. We suggest to use quantum emitters to test nonlocal effects in experimentally feasible configurations.

  10. Effect of plasmonic near field on the emittance of plasmon-enhanced photocathode

    CERN Document Server

    Jiang, Zeng-gong; Li, Xu-dong; Zhang, Meng; Gu, Duan

    2016-01-01

    The introduction of the surface plasmon polarizations makes the emittance of the photocathode complicated. In this paper, the emittance of plasmon-enhanced photocathode is analyzed. It is first demonstrated that the plasmonic near field can increase the emittance of the plasmon-enhanced photocathode. A simulation method has been used to estimate the emittance caused by plasmonic near field, and the suppression method also has been discussed, both of which are significant for the design of high performance plasmon-enhanced photocathode.

  11. Cooperative behavior of quantum dipole emitters coupled to a zero-index nanoscale waveguide

    OpenAIRE

    Sokhoyan, Ruzan; Harry A. Atwater

    2015-01-01

    We study cooperative behavior of quantum dipole emitters coupled to a rectangular waveguide with dielectric core and silver cladding. We investigate cooperative emission and inter-emitter entanglement generation phenomena for emitters whose resonant frequencies are near the frequency cutoff of the waveguide, where the waveguide effectively behaves as zero-index metamaterial. We show that coupling emitters to a zero-index waveguide allows one to relax the constraint on precision positioning of...

  12. Fission- and alpha-track study of biogeochemistry of plutonium and uranium in carbonates of Bikini and Enewetak atolls. Summary report, 1 July 1974--31 August 1977

    International Nuclear Information System (INIS)

    Alpha emitters of pCi/g amounts have been detected with a resolution of a few micrometers using a solid state track detector (cellulose nitrate) to map the activity in a coral sample from Bikini. Calibration methods used include: a Pu source of 0.15 μCi in conjunction with polycarbonate and CaCO3 absorbers of different thicknesses (2 to 30 micrometers), and a powdered coral sample which had been analyzed previously for alpha emitters by chemical methods in conjunction with an alpha spectrometer. 0.04 mm3 can be measured routinely; lower concentrations can be determined but with less resolution. The alpha emitter concentration in CaCO3 of the coral Favites virens from Bikini lagoon was analyzed by placing the detector directly on the slab sample for thirty days. Analyses of sections and thin sections of this coral slab cut perpendicular to one another, but parallel to the direction of coral growth, give very different concentrations and distributions of alpha emitters

  13. CAP Reform and the Doha Development Agenda

    NARCIS (Netherlands)

    van Dijck, P.; Faber, G.

    2004-01-01

    The CAP reforms that the EU accepted in June 2003 will partially decouple direct income payments to farmers from production and make these payments conditional on cross-compliance. The reforms are driven by enlargement of EU membership, budgetary constraints, mounting pressures from diverse animal w

  14. The Effectiveness of Caps on Political Lobbying

    NARCIS (Netherlands)

    Matejka, M.; Onderstal, A.M.; De Waegenaere, A.M.B.

    2002-01-01

    In this paper, we analyze a lobby game, modelled as an all-pay auction in which interest groups submit bids in order to obtain a political prize.The bids are restricted to be below a cap imposed by the government.For both an incomplete and a complete information setting we show the following results

  15. INTERNATIONAL WHEAT PRICE TRANSMISSION AND CAP REFORM

    OpenAIRE

    Thompson, Stanley R.; Bohl, Martin T.

    1999-01-01

    We illustrate how CAP policy reforms influence the transmission of world prices to domestic markets. Monthly wheat price data in Germany are used to obtain price transmission elasticities. Correctly accounting for structural breaks and the time series properties of the data yield transmission elasticities that differ dramatically among policy regimes.

  16. Knowledge Management at Cap Gemini Nederland

    NARCIS (Netherlands)

    M.J. Vlaanderen (Marie Jose)

    1998-01-01

    textabstractThe theme of this paper is knowledge management (KM) at an organization that provides information technology (IT) services. It is based on the results of a KM-survey of the Finance Division of Cap Gemini (CG) conducted during the spring of 1997.

  17. ATLAS: End-cap Toroid assembly

    CERN Multimedia

    2006-01-01

    In building 191 and building 180- assembly of this massive piece.To reach the top of the end-cap the cranes has to be used and during the assembly you can see welding and hear many tools running background.

  18. Emitter/absorber interface of CdTe solar cells

    Science.gov (United States)

    Song, Tao; Kanevce, Ana; Sites, James R.

    2016-06-01

    The performance of CdTe solar cells can be very sensitive to the emitter/absorber interface, especially for high-efficiency cells with high bulk lifetime. Performance losses from acceptor-type interface defects can be significant when interface defect states are located near mid-gap energies. Numerical simulations show that the emitter/absorber band alignment, the emitter doping and thickness, and the defect properties of the interface (i.e., defect density, defect type, and defect energy) can all play significant roles in the interface recombination. In particular, a type I heterojunction with small conduction-band offset (0.1 eV ≤ ΔEC ≤ 0.3 eV) can help maintain good cell efficiency in spite of high interface defect density, much like with Cu(In,Ga)Se2 (CIGS) cells. The basic principle is that positive ΔEC, often referred to as a "spike," creates an absorber inversion and hence a large hole barrier adjacent to the interface. As a result, the electron-hole recombination is suppressed due to an insufficient hole supply at the interface. A large spike (ΔEC ≥ 0.4 eV), however, can impede electron transport and lead to a reduction of photocurrent and fill-factor. In contrast to the spike, a "cliff" (ΔEC CdTe solar cells, but the CdS/CdTe interface is in the cliff category and is not favorable from the band-offset perspective. The ΔEC of other n-type emitter choices, such as (Mg,Zn)O, Cd(S,O), or (Cd,Mg)Te, can be tuned by varying the elemental ratio for an optimal positive value of ΔEC. These materials are predicted to yield higher voltages and would therefore be better candidates for the CdTe-cell emitter.

  19. Alpha Shapes and Proteins

    DEFF Research Database (Denmark)

    Winter, Pawel; Sterner, Henrik; Sterner, Peter

    2009-01-01

    We provide a unified description of (weighted) alpha shapes, beta shapes and the corresponding simplicialcomplexes. We discuss their applicability to various protein-related problems. We also discuss filtrations of alpha shapes and touch upon related persistence issues.We claim that the full...... potential of alpha-shapes and related geometrical constructs in protein-related problems yet remains to be realized and verified. We suggest parallel algorithms for (weighted) alpha shapes, and we argue that future use of filtrations and kinetic variants for larger proteins will need such implementation....

  20. Using antennas separated in flight direction to avoid effect of emitter clock drift in geolocation

    Science.gov (United States)

    Ormesher, Richard C.; Bickel, Douglas L

    2012-10-23

    The location of a land-based radio frequency (RF) emitter is determined from an airborne platform. RF signaling is received from the RF emitter via first and second antennas. In response to the received RF signaling, signal samples for both antennas are produced and processed to determine the location of the RF emitter.

  1. Spacecraft charging control by thermal, field emission with lanthanum-hexaboride emitters

    Science.gov (United States)

    Morris, J. F.

    1978-01-01

    Thermal, field emitters of lanthanum (or perhaps cerium) hexaboride (LaB6) with temperature variability up to about 1500K are suggested for spacecraft charging control. Such emitters operate at much lower voltages with considerably more control and add plasma-diagnostic versatility. These gains should outweigh the additional complexity of providing heat for the LaB6 thermal, field emitter.

  2. Calculated and measured emittance of sputter-type negative-ion source

    International Nuclear Information System (INIS)

    A method for calculating the beam current and emittance of a negative ion beam from a sputter-type source is described. Calculations are compared to measured emittance. The dependence of the emittance on ion source parameters such as cathode shape, exit aperture diameter, and cathode voltage is discussed

  3. Thick target yield measurement of {sup 211}At through the nuclear reaction {sup 209}Bi({alpha}, 2n)

    Energy Technology Data Exchange (ETDEWEB)

    Alfarano, A [Institute for Health and Consumer Protection, IHCP, Joint Research Centre, via E. Fermi 1, 21020 Ispra, Varese (Italy); Abbas, K [Institute for Health and Consumer Protection, IHCP, Joint Research Centre, via E. Fermi 1, 21020 Ispra, Varese (Italy); Holzwarth, U [Institute for Health and Consumer Protection, IHCP, Joint Research Centre, via E. Fermi 1, 21020 Ispra, Varese (Italy); Bonardi, M [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, 20090 Segrate, Milan (Italy); Groppi, F [Universita degli Studi di Milano and INFN-Milano, LASA, Radiochemistry Laboratory, via F.lli Cervi 201, 20090 Segrate, Milan (Italy); Alfassi, Z [Department of Nuclear Engineering, Ben Gurion University, 84105 Beer Sheva (Israel); Menapace, E [ENEA, Applied Physics Division, Bologna (Italy); Gibson, P N [Institute for Health and Consumer Protection, IHCP, Joint Research Centre, via E. Fermi 1, 21020 Ispra, Varese (Italy)

    2006-05-15

    Radionuclide Therapy (RNT) and Radioimmunotherapy (RIT) are potentially of great interest for cancer therapy. In many therapeutic applications alpha emitters should be much more effective than already-approved beta emitters due to the short range and high linear energy transfer of alpha particles. {sup 213}Bi is an important alpha emitter already used in clinical trials but the half-life of this radioisotope is short (46 minutes) and so its use is limited for certain therapies. {sup 211}At is potentially very interesting for medical purposes because of its longer half-life of 7.2 hours, and suitable decay scheme. We have studied the cyclotron-based production of {sup 211}At via the reaction {sup 209}Bi({alpha}, 2n), this production route probably being the most promising in the long term. The energy dependence of thick target yields and the reaction cross sections for the production of {sup 211}At and {sup 210}At were determined and found to be in good agreement with literature. The best energy to produce {sup 211}At is 28-29 MeV. The possible production of the undesired, highly radiotoxic, and long-lived alpha-emitting {sup 210}Po (138.38 days), which is produced from decay of {sup 210}At, is also discussed.

  4. Performance comparison of scintillators for alpha particle detectors

    Science.gov (United States)

    Morishita, Yuki; Yamamoto, Seiichi; Izaki, Kenji; Kaneko, Junichi H.; Toui, Kohei; Tsubota, Youichi; Higuchi, Mikio

    2014-11-01

    Scintillation detectors for alpha particles are often used in nuclear fuel facilities. Alpha particle detectors have also become important in the research field of radionuclide therapy using alpha emitters. ZnS(Ag) is the most often used scintillator for alpha particle detectors because its light output is high. However, the energy resolution of ZnS(Ag)-based scintillation detectors is poor because they are not transparent. A new ceramic sample, namely the cerium doped Gd2Si2O7 (GPS) scintillator, has been tested as alpha particle detector and its performances have been compared to that one of three different scintillating materials: ZnS(Ag), GAGG and a standard plastic scintillator. The different scintillating materials have been coupled to two different photodetectors, namely a photomultiplier tube (PMT) and a Silicon Photo-multiplier (Si-PM): the performances of each detection system have been compared. Promising results as far as the energy resolution performances (10% with PMT and 14% with Si-PM) have been obtained in the case of GPS and GAGG samples. Considering the quantum efficiencies of the photodetectors under test and their relation to the emission wavelength of the different scintillators, the best results were achieved coupling the GPS with the PMT and the GAGG with the Si-PM

  5. Targeted Alpha Therapy: From Alpha to Omega

    International Nuclear Information System (INIS)

    This review covers the broad spectrum of Targeted Alpha Therapy (TAT) research in Australia; from in vitro and in vivo studies to clinical trials. The principle of tumour anti-vascular alpha therapy (TAVAT) is discussed in terms of its validation by Monte Carlo calculations of vascular models and the potential role of biological dosimetry is examined. Summmary of this review is as follows: 1. The essence of TAT 2. Therapeutic objectives 3. TAVAT and Monte Carlo microdosimetry 4. Biological dosimetry 5. Preclinical studies 6. Clinical trials 7. What next? 8. Obstacles. (author)

  6. Structure, stability and folding of the alpha-helix.

    Science.gov (United States)

    Doig, A J; Andrew, C D; Cochran, D A; Hughes, E; Penel, S; Sun, J K; Stapley, B J; Clarke, D T; Jones, G R

    2001-01-01

    Pauling first described the alpha-helix nearly 50 years ago, yet new features of its structure continue to be discovered, using peptide model systems, site-directed mutagenesis, advances in theory, the expansion of the Protein Data Bank and new experimental techniques. Helical peptides in solution form a vast number of structures, including fully helical, fully coiled and partly helical. To interpret peptide results quantitatively it is essential to use a helix/coil model that includes the stabilities of all these conformations. Our models now include terms for helix interiors, capping, side-chain interactions, N-termini and 3(10)-helices. The first three amino acids in a helix (N1, N2 and N3) and the preceding N-cap are unique, as their amide NH groups do not participate in backbone hydrogen bonding. We surveyed their structures in proteins and measured their amino acid preferences. The results are predominantly rationalized by hydrogen bonding to the free NH groups. Stabilizing side-chain-side-chain energies, including hydrophobic interactions, hydrogen bonding and polar/non-polar interactions, were measured accurately in helical peptides. Helices in proteins show a preference for having approximately an integral number of turns so that their N- and C-caps lie on the same side. There are also strong periodic trends in the likelihood of terminating a helix with a Schellman or alpha L C-cap motif. The kinetics of alpha-helix folding have been studied with stopped-flow deep ultraviolet circular dichroism using synchrotron radiation as the light source; this gives a far superior signal-to-noise ratio than a conventional instrument. We find that poly(Glu), poly(Lys) and alanine-based peptides fold in milliseconds, with longer peptides showing a transient overshoot in helix content.

  7. Facially amphiphilic thiol capped gold and silver nanoparticles

    OpenAIRE

    Bhat, Shreedhar; Maitra, Uday

    2008-01-01

    A series of bile acid-derived facially amphiphilic thiols have been used to cap sliver and gold nanoparticles. The self-assembling properties of these steroid-capped nanoparticles have been investigated and reported in this article.

  8. Facially amphiphilic thiol capped gold and silver nanoparticles

    Indian Academy of Sciences (India)

    Shreedhar Bhata; Uday Maitra

    2008-11-01

    A series of bile acid-derived facially amphiphilic thiols have been used to cap sliver and gold nanoparticles. The self-assembling properties of these steroid-capped nanoparticles have been investigated and reported in this article.

  9. Predicting the Redshift 2 H-Alpha Luminosity Function Using [OIII] Emission Line Galaxies

    Science.gov (United States)

    Mehta, Vihang; Scarlata, Claudia; Colbert, James W.; Dai, Y. S.; Dressler, Alan; Henry, Alaina; Malkan, Matt; Rafelski, Marc; Siana, Brian; Teplitz, Harry I.; Bagley, Micaela; Beck, Melanie; Ross, Nathaniel R.; Rutkowski, Michael; Wang, Yun

    2015-01-01

    Upcoming space-based surveys such as Euclid and WFIRST-AFTA plan to measure Baryonic Acoustic Oscillations (BAOs) in order to study dark energy. These surveys will use IR slitless grism spectroscopy to measure redshifts of a large number of galaxies over a significant redshift range. In this paper, we use the WFC3 Infrared Spectroscopic Parallel Survey (WISP) to estimate the expected number of H-alpha emitters observable by these future surveys. WISP is an ongoing Hubble Space Telescope slitless spectroscopic survey, covering the 0.8 - 1.65 micrometers wavelength range and allowing the detection of H-alpha emitters up to z approximately equal to 1.5 and [OIII] emitters to z approximately equal to 2.3. We derive the H-alpha-[OIII] bivariate line luminosity function for WISP galaxies at z approximately equal to 1 using a maximum likelihood estimator that properly accounts for uncertainties in line luminosity measurement, and demonstrate how it can be used to derive the H-alpha luminosity function from exclusively fitting [OIII] data. Using the z approximately equal to 2 [OIII] line luminosity function, and assuming that the relation between H-alpha and [OIII] luminosity does not change significantly over the redshift range, we predict the H-alpha number counts at z approximately equal to 2 - the upper end of the redshift range of interest for the future surveys. For the redshift range 0.7 less than z less than 2, we expect approximately 3000 galaxies per sq deg for a flux limit of 3 x 10(exp -16) ergs per sec per sq cm (the proposed depth of Euclid galaxy redshift survey) and approximately 20,000 galaxies per sq deg for a flux limit of approximately 10(exp -16) ergs per sec per sq cm (the baseline depth of WFIRST galaxy redshift survey).

  10. A improved method for the analysis of alpha spectra

    International Nuclear Information System (INIS)

    In this work we describe a methodology, developed in the last years, for the analysis of alpha emitters spectra, obtained with implanted ion detectors, that tend to solve some of the problems that shows this type of spectra. This is an improved methodology respect to that described in a previous publication. The method is based on the application of a mathematical function that allows to model the tail of an alpha peak, to evaluate the part of the peak that is not seen in the cases of partial superposition with another peak. Also, a calculation program that works in a semiautomatic way, with the possibility of interactive intervention of the analyst, has been developed simultaneously and is described in detail. (author)

  11. Alpha radioactivity for proton-rich even Pb isotopes

    Indian Academy of Sciences (India)

    Arati Devi; S Prakash; I Mehrotra

    2009-04-01

    Half-lives for alpha radioactivity from proton-rich even Pb isotopes in the range = 182–202 have been calculated using the unified fission-like approach. The geometrical shape of the potential barrier is parametrized in terms of a highly versatile, asymmetric and analytically solvable form of potential based on Ginnochio’s potential. Good agreement with the experimental data has been obtained with the variation of just one parameter. Half-lives of three unknown alpha emitters in the neutron-deficient Pb chain (198Pb, 200Pb and 204Pb) have been predicted. The exact expression for the transmission coefficient has been compared with those obtained from WKB approximation method for symmetric Eckart potential.

  12. Buffett’s Alpha

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Kabiller, David; Heje Pedersen, Lasse

    Berkshire Hathaway has realized a Sharpe ratio of 0.76, higher than any other stock or mutual fund with a history of more than 30 years, and Berkshire has a significant alpha to traditional risk factors. However, we find that the alpha becomes insignificant when controlling for exposures to Betting...

  13. Exploring plasmonic coupling in hole-cap arrays

    OpenAIRE

    Schmidt, Thomas M.; Maj Frederiksen; Vladimir Bochenkov; Sutherland, Duncan S

    2015-01-01

    The plasmonic coupling between gold caps and holes in thin films was investigated experimentally and through finite-difference time-domain (FDTD) calculations. Sparse colloidal lithography combined with a novel thermal treatment was used to control the vertical spacing between caps and hole arrays and compared to separated arrays of holes or caps. Optical spectroscopy and FDTD simulations reveal strong coupling between the gold caps and both Bloch Wave-surface plasmon polariton (BW-SPP) modes...

  14. Linking Ly-alpha and Low-Ionization Transitions at Low Optical Depth

    CERN Document Server

    Jaskot, A E

    2014-01-01

    We suggest that low optical depth in the Lyman continuum (LyC) may relate the Ly-alpha emission, C II and Si II absorption, and C II* and Si II* emission seen in high-redshift galaxies. We base this analysis on Hubble Space Telescope COS spectra of four Green Pea (GP) galaxies, which may be analogs of z>2 Ly-alpha emitters (LAEs). In the two GPs with the strongest Ly-alpha emission, the Ly-alpha line profiles do not show the typical effects of resonant scattering. Instead, the Ly-alpha profiles resemble the H-alpha line profiles of evolved star ejecta, suggesting that the Ly-alpha emission originates from a low column density and similar outflow geometry. The weak C II absorption and presence of non-resonant C II* emission in these GPs support this interpretation and imply a low LyC optical depth along the line of sight. In two additional GPs, weak Ly-alpha emission and strong C II absorption suggest a higher optical depth. These two GPs differ in their Ly-alpha profile shapes and C II* emission strengths, ho...

  15. Emittance Measurements from a Laser Driven Electron Injector

    International Nuclear Information System (INIS)

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 (angstrom), the LCLS requires an electron injector that can produce an electron beam with approximately 1 π mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the laser and electron beam at the GTF. A convolved measurement of the relative timing between the laser and the rf phase in the gun shows that the jitter is less than 2.5 ps rms. Emittance measurements of the electron beam at 35 MeV are reported as a function of the (Gaussian) pulse length and transverse profile of the laser as well as the charge of the electron beam at constant phase and gradient in both the gun and linac. At 1 nC the emittance was found to be ∼ 13 π mm-mrad for 5 ps and 8 ps long laser pulses. At 0.5 nC the measured emittance decreased approximately 20% in the 5 ps case and 40% in the 8 ps case. These measurements are between 40-80% higher than simulations for similar experimental conditions. In addition, the thermal emittance of the electron beam was measured to be 0.5 π mm-mrad

  16. High-current lanthanum-hexaboride electron emitter for a quasi-stationary arc plasma generator

    Energy Technology Data Exchange (ETDEWEB)

    Davydenko, V. I., E-mail: V.I.Davydenko@inp.nsk.su; Ivanov, A. A., E-mail: A.A.Ivanov@inp.nsk.su; Shul’zhenko, G. I. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2015-11-15

    A high-current electron emitter on the basis of lanthanum hexaboride is developed for quasi-stationary arc plasma generators of ion sources. The emitter consists of a set of LaB{sub 6} washers interleaved with washers made of thermally extended graphite. The emitter is heated by the current flowing through the graphite washers. The thermal regime of emitter operation during plasma generation is considered. The emitter has been successfully used in the ion sources of the diagnostic injectors of fast hydrogen atomic beams.

  17. Experimental study of coherent synchrotron radiation in the emittance exchange line at the A0-photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Thangaraj, Jayakar C.T.; Thurman-Keup, R.; Johnson, A.; Lumpkin, A.H.; Edwards, H.; Ruan, J.; Santucci, J.; Sun, Y.E.-; Church, M.; /Fermilab; Piot, P.; /Fermilab /Northern Illinois U.

    2010-08-01

    Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchanger to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at A0 photoinjector.

  18. Experimental study of coherent synchrotron radiation in the emittance exchange line at the A0-photoinjector

    CERN Document Server

    Thangaraj, Jayakar C T; Johnson, A; Lumpkin, A H; Edwards, H; Ruan, J; Santucci, J; Sun, Y E -; Church, M; Piot, P

    2012-01-01

    Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.

  19. Alpha-particle diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Young, K.M.

    1991-01-01

    This paper will focus on the state of development of diagnostics which are expected to provide the information needed for {alpha}- physics studies in the future. Conventional measurement of detailed temporal and spatial profiles of background plasma properties in DT will be essential for such aspects as determining heating effectiveness, shaping of the plasma profiles and effects of MHD, but will not be addressed here. This paper will address (1) the measurement of the neutron source, and hence {alpha}-particle birth profile, (2) measurement of the escaping {alpha}-particles and (3) measurement of the confined {alpha}-particles over their full energy range. There will also be a brief discussion of (4) the concerns about instabilities being generated by {alpha}-particles and the methods necessary for measuring these effects. 51 refs., 10 figs.

  20. Imaging alpha particle detector

    Science.gov (United States)

    Anderson, D.F.

    1980-10-29

    A method and apparatus for detecting and imaging alpha particles sources is described. A dielectric coated high voltage electrode and a tungsten wire grid constitute a diode configuration discharge generator for electrons dislodged from atoms or molecules located in between these electrodes when struck by alpha particles from a source to be quantitatively or qualitatively analyzed. A thin polyester film window allows the alpha particles to pass into the gas enclosure and the combination of the glass electrode, grid and window is light transparent such that the details of the source which is imaged with high resolution and sensitivity by the sparks produced can be observed visually as well. The source can be viewed directly, electronically counted or integrated over time using photographic methods. A significant increase in sensitivity over other alpha particle detectors is observed, and the device has very low sensitivity to gamma or beta emissions which might otherwise appear as noise on the alpha particle signal.

  1. CMS end-cap yoke at the detector's assembly site.

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    The magnetic flux generated by the superconducting coil in the CMS detector is returned via an iron yoke comprising three end-cap discs at each end (end-cap yoke) and five concentric cylinders (barrel yoke). This picture shows the first of three end-cap discs (red) seen through the outer cylinder of the vacuum tank which will house the superconducting coil.

  2. Preparation and preclinical evaluation of {sup 211}At-labelled compounds for {alpha}-particle radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R.H.

    1994-12-31

    The interest for {alpha}-particle emitters in internal radiotherapy is increasing due to improved conjugation chemistry. Experimental work has concentrated on {sup 211}At and {sup 212}Bi since these to nuclides have radiochemical and physical properties suitable for medical application. In this report it is demonstrated that biologically active {sup 211}At-labelled compounds can be prepared within a relatively short time allowing utilization of this 7.2 h {alpha}-particle. It is further shown that {sup 211}At-TP-3 treatment of human osteosarcoma in vitro gives promising therapeutic ratios. 76 refs., 5 figs., 3 tabs.

  3. Long-term aqueous alteration kinetics of an alpha-doped SON68 borosilicate glass

    OpenAIRE

    TRIBET M.; ROLLAND Séverine; S. Peuget; Magnin, Magali; BROUDIC Véronique; JANSSEN ARNE; Wiss, Thierry; JEGOU C.; Toulhoat, Pierre

    2013-01-01

    The long-term behavior of nuclear glass subjected to alpha radiation by minor actinides must be investigated with a view to geological disposal. This study focuses on the effect of alpha radiation on the chemical reactivity of R7T7 glass with pure water, mainly on the residual alteration rate regime. A glass specimen doped with 0.85 wt% 239PuO2 (α emitter) is leached under static conditions in argon atmosphere at 90°C and at a high surface-area-to-volume ratio (S/V = 20 cm-1). The alteration ...

  4. Evolution of the spherical cavity radius generated around a subsurface drip emitter

    Directory of Open Access Journals (Sweden)

    M. Gil

    2010-06-01

    Full Text Available The emitter discharge in subsurface drip irrigation can be affected by soil properties. A positive pressure develops at the emitter outlet where a spherical cavity is assumed to form. In steady-state conditions, the pressure in the soil relates to soil hydraulic properties, the emitter discharge, and the cavity radius. This pressure in the soil is very sensitive to the cavity radius. In this paper, the development of the cavity around the emitter outlet was measured for various emitter discharges in laboratory tests carried out in containers with uniform loamy soils. A trend between soil pressure and emitter discharge was established that illustrates the performance of buried emitters in the field. Its application to the prediction of water distribution in subsurface drip irrigation units and its effect on the estimation of irrigation performance are also shown.

  5. Greening CAP payments: a missed opportunity?

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, Alan

    2013-01-15

    At an important point in the current reform of the Common Agricultural Policy (CAP), a new IIEA policy brief by Professor Alan Matthews, one of the EU’s foremost experts on the topic, considers proposals to green direct farm payments. Professor Matthews argues that proposed greening of direct payments – the key innovation in the current round of CAP Reform – look likely to fail. While greening may survive as a concept, the likely outcome of the negotiations between Agriculture Ministers and the European Parliament will deliver little practical environmental benefit. The paper examines the rationale underpinning greening, arguing that it exists to justify the continuation of a large agricultural budget, explores reasons for the apparent failure of the proposals, and reflects on the implications for future efforts to better integrate environmental objectives into EU agriculture policy. This is the first in a series of Environment Nexus policy briefs by leading experts in the fields of agriculture, energy, climate change and water.

  6. Should we geoengineer larger ice caps?

    CERN Document Server

    Haqq-Misra, Jacob

    2015-01-01

    The climate of Earth is susceptible to catastrophes that could threaten the longevity of human civilization. Geoengineering to reduce incoming solar radiation has been suggested as a way to mediate the warming effects of contemporary climate change, but a geoengineering program for thousands of years could also be used to enlarge the size of the polar ice caps and create a permanently cooler climate. Such a large ice cap state would make Earth less susceptible to climate threats and could allow human civilization to survive further into the future than otherwise possible. Intentionally extending Earth's glacial coverage will require uninterrupted commitment to this program for millenia but would ultimately reach a cooler equilibrium state where geoengineering is no longer needed. Whether or not this program is ever attempted, this concept illustrates the need to identify preference among potential climate states to ensure the long-term success of civilization.

  7. Status of the AlCap experiment

    CERN Document Server

    Litchfield, R Phillip

    2015-01-01

    The AlCap experiment is a joint project between the COMET and Mu2e collaborations. Both experiments intend to look for the lepton-flavour violating conversion $\\mu + A \\rightarrow e + A$, using tertiary muons from high-power pulsed proton beams. In these experiments the products of ordinary muon capture in the muon stopping target are an important concern, both in terms of hit rates in tracking detectors and radiation damage to equipment. The goal of the AlCap experiment is to provide precision measurements of the products of nuclear capture on Aluminium, which is the favoured target material for both COMET and Mu2e. The results will be used for optimising the design of both conversion experiments, and as input to their simulations. Data was taken in December 2013 and is currently being analysed.

  8. Electrically pumped single-defect light emitters in WSe$_2$

    CERN Document Server

    Schwarz, S; Withers, F; Maguire, J K; Foster, A P; Dufferwiel, S; Hague, L; Makhonin, M N; Wilson, L R; Geim, A K; Novoselov, K S; Tartakovskii, A I

    2016-01-01

    Recent developments in fabrication of van der Waals heterostructures enable new type of devices assembled by stacking atomically thin layers of two-dimensional materials. Using this approach, we fabricate light-emitting devices based on a monolayer WSe$_2$, and also comprising boron nitride tunnelling barriers and graphene electrodes, and observe sharp luminescence spectra from individual defects in WSe$_2$ under both optical and electrical excitation. This paves the way towards the realization of electrically-pumped quantum emitters in atomically thin semiconductors. In addition we demonstrate tuning by more than 1 meV of the emission energy of the defect luminescence by applying a vertical electric field. This provides an estimate of the permanent electric dipole created by the corresponding electron-hole pair. The light-emitting devices investigated in our work can be assembled on a variety of substrates enabling a route to integration of electrically pumped single quantum emitters with existing technologi...

  9. Electron Cloud at Low Emittance in CesrTA

    International Nuclear Information System (INIS)

    The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud's effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results.

  10. Quantum Emitters near Layered Plasmonic Nanostructures: Decay Rate Contributions

    CERN Document Server

    Pors, Anders

    2016-01-01

    We introduce a numerical framework for calculating decay rate contributions when excited two-level quantum emitters are located near layered plasmonic nanostructures, particularly emphasizing the case of plasmonic nanostructures atop metal substrates where three decay channels exist: free space radiation, Ohmic losses, and excitation of surface plasmon polaritons (SPPs). The calculation of decay rate contributions is based on Huygen's equivalence principle together with a near-field to far-field transformation of the local electric field, thereby allowing us to discern the part of the electromagnetic field associated with free propagating waves rather than SPPs. The methodology is applied to the case of an emitter inside and near a gap-plasmon resonator, emphasizing strong position and orientation dependencies of the total decay rate, contributions of different decay channels, radiation patterns, and directivity of SPP excitation.

  11. Emittance preservation during bunch compression with a magnetized beam

    Energy Technology Data Exchange (ETDEWEB)

    Stratakis, Diktys [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-02

    The deleterious effects of coherent synchrotron radiation (CSR) on the phase-space and energy spread of high-energy beams in accelerator light sources can significantly constrain the machine design and performance. In this paper, we present a simple method to preserve the beam emittance by means of using magnetized beams that exhibit a large aspect ratio on their transverse dimensions. The concept is based on combining a finite solenoid field where the beam is generated together with a special optics adapter. Numerical simulations of this new type of beam source show that the induced phase-space density growth can be notably suppressed to less than 1% for any bunch charge. This work elucidates the key parameters that are needed for emittance preservation, such as the required field and aspect ratio for a given bunch charge.

  12. Crystalline silicon solar cells with high resistivity emitter

    Science.gov (United States)

    Panek, P.; Drabczyk, K.; Zięba, P.

    2009-06-01

    The paper presents a part of research targeted at the modification of crystalline silicon solar cell production using screen-printing technology. The proposed process is based on diffusion from POCl3 resulting in emitter with a sheet resistance on the level of 70 Ω/□ and then, shaped by high temperature passivation treatment. The study was focused on a shallow emitter of high resistivity and on its influence on output electrical parameters of a solar cell. Secondary ion mass spectrometry (SIMS) has been employed for appropriate distinguishing the total donor doped profile. The solar cell parameters were characterized by current-voltage characteristics and spectral response (SR) methods. Some aspects playing a role in suitable manufacturing process were discussed. The situation in a photovoltaic industry with emphasis on silicon supply and current prices of solar cells, modules and photovoltaic (PV) systems are described. The economic and quantitative estimation of the PV world market is shortly discussed.

  13. Coupling of individual quantum emitters to channel plasmons

    CERN Document Server

    Bermúdez-Ureña, Esteban; Geiselmann, Michael; Marty, Renaud; Radko, Ilya P; Holmgaard, Tobias; Alaverdyan, Yury; Moreno, Esteban; García-Vidal, Francisco J; Bozhevolnyi, Sergey I; Quidant, Romain

    2015-01-01

    Efficient light-matter interaction lies at the heart of many emerging technologies that seek on-chip integration of solid-state photonic systems. Plasmonic waveguides, which guide the radiation in the form of strongly confined surface plasmon-polariton modes, represent a promising solution to manipulate single photons in coplanar architectures with unprecedented small footprints. Here we demonstrate coupling of the emission from a single quantum emitter to the channel plasmon polaritons supported by a V-groove plasmonic waveguide. Extensive theoretical simulations enable us to determine the position and orientation of the quantum emitter for optimum coupling. Concomitantly with these predictions, we demonstrate experimentally that 42% of a single nitrogen vacancy centre emission efficiently couples into the supported modes of the V-groove. This work paves the way towards practical realization of efficient and long distance transfer of energy for integrated solid-state quantum systems.

  14. A New SIMOX Emitter Switching Thyristor--BO-ECT

    Institute of Scientific and Technical Information of China (English)

    ZHANG Bo; Alex Q.Huang

    2001-01-01

    SIMOX Emitter switching thyristor(SIMEST) is a new MOS-gated thyristor with highvoltage current saturation capability. In this paper,an improved SIMEST, the Buried-Oxide Emitter Controlled Thyristor (BO-ECT) is proposed. Comparing with the SIMEST, the BO-ECT not only has a simple gate and source metalization structure and is therefore easy for layout design, but it also has an improved high-voltage current saturation capability. The operational mechanism and the forward biased safe operating area (FBSOA) are analyzed. Two-dimensional simulation results indicate that the BO-ECT has a much lower forward voltage drop than that of the IGBT while at the same time has a wider or similar FBSOA as the IGBT.

  15. Extended emitter target tracking using GM-PHD filter.

    Directory of Open Access Journals (Sweden)

    Youqing Zhu

    Full Text Available If equipped with several radar emitters, a target will produce more than one measurement per time step and is denoted as an extended target. However, due to the requirement of all possible measurement set partitions, the exact probability hypothesis density filter for extended target tracking is computationally intractable. To reduce the computational burden, a fast partitioning algorithm based on hierarchy clustering is proposed in this paper. It combines the two most similar cells to obtain new partitions step by step. The pseudo-likelihoods in the Gaussian-mixture probability hypothesis density filter can then be computed iteratively. Furthermore, considering the additional measurement information from the emitter target, the signal feature is also used in partitioning the measurement set to improve the tracking performance. The simulation results show that the proposed method can perform better with lower computational complexity in scenarios with different clutter densities.

  16. Field emission from nanotube bundle emitters at low fields

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Q.H.; Corrigan, T.D.; Dai, J.Y.; Chang, R.P. [Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Krauss, A.R. [Materials Science and Chemistry Divisions, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    1997-06-01

    The fabrication of nanotube field emitters with an onset field as low as 0.8 V/{mu}m is described and the low-field electron emission mechanism is discussed. These emitters are made using nanotube cathode deposit with the addition of epoxy resin. The preferred orientation of nanotubes in nanotube bundles of the deposit is preserved. The nanotube tips are sharpened by exposing the nanotube bundle surface to a microwave oxygen plasma. The local-field enhancement factor is estimated to be 8000 by using the Fowler{endash}Nordheim equation. The low onset field is attributed to the well-distributed, highly orientated sharp tips at the sample surface. {copyright} {ital 1997 American Institute of Physics.}

  17. Electron Cloud at Low Emittance in CesrTA

    CERN Document Server

    Palmer, Mark; Billing, Michael; Calvey, Joseph; Conolly, Christopher; Crittenden, James; Dobbins, John; Dugan, Gerald; Eggert, Nicholas; Fontes, Ernest; Forster, Michael; Gallagher, Richard; Gray, Steven; Greenwald, Shlomo; Hartill, Donald; Hopkins, Walter; Kreinick, David; Kreis, Benjamin; Leong, Zhidong; Li, Yulin; Liu, Xianghong; Livezey, Jesse; Lyndaker, Aaron; Makita, Junki; McDonald, Michael; Medjidzade, Valeri; Meller, Robert; O'Connell, Tim; Peck, Stuart; Peterson, Daniel; Ramirez, Gabriel; Rendina, Matthew; Revesz, Peter; Rider, Nate; Rice, David; Rubin, David; Sagan, David; Savino, James; Schwartz, Robert; Seeley, Robert; Sexton, James; Shanks, James; Sikora, John; Smith, Eric; Strohman, Charles; Williams, Heather; Antoniou, Fanouria; Calatroni, Sergio; Gasior, Marek; Jones, Owain Rhodri; Papaphilippou, Yannis; Pfingstner, Juergen; Rumolo, Giovanni; Schmickler, Hermann; Taborelli, Mauro; Asner, David; Boon, Laura; Garfinkel, Arthur; Byrd, John; Celata, Christine; Corlett, John; De Santis, Stefano; Furman, Miguel; Jackson, Alan; Kraft, Rick; Munson, Dawn; Penn, Gregory; Plate, David; Venturini, Marco; Carlson, Benjamin; Demma, Theo; Dowd, Rohan; Flanagan, John; Jain, Puneet; Kanazawa, Ken-ichi; Kubo, Kiyoshi; Ohmi, Kazuhito; Sakai, Hiroshi; Shibata, Kyo; Suetsugu, Yusuke; Tobiyama, Makoto; Gonnella, Daniel; Guo, Weiming; Harkay, Katherine; Holtzapple, Robert; Jones, James; Wolski, Andrzej; Kharakh, David; Ng, Johnny; Pivi, Mauro; Wang, Lanfa; Ross, Marc; Tan, Cheng-Yang; Zwaska, Robert; Schachter, Levi; Wilkinson, Eric

    2010-01-01

    The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud’s effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results

  18. First observation of the exchange of transverse and longitudinal emittances

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, J.; Johnson, A.S.; Lumpkin, A.H.; Thurman-Keup, R.; Edwards, H.; Fliller, R.P.; Koeth, T.; Sun, Y.-E; /Fermilab

    2011-02-01

    An experimental program to demonstrate a novel phase space manipulation in which the horizontal and longitudinal emittances of a particle beam are exchanged has been completed at the Fermilab A0 Photoinjector. A new beamline, consisting of a TM{sub 110} deflecting mode cavity flanked by two horizontally dispersive doglegs has been installed. We report on the first direct observation of transverse and longitudinal emittance exchange: {l_brace}{var_epsilon}{sub x}{sup n}, {var_epsilon}{sub y}{sup n}, {var_epsilon}{sub z}{sup n}{r_brace} = {l_brace} 2.9 {+-} 0.1, 2.4 {+-} 0.1, 13.1 {+-} 1.3{r_brace} {yields} {l_brace}11.3 {+-} 1.1, 2.9 {+-} 0.5, 3.1 {+-} 0.3{r_brace} mm-mrad.

  19. Matching of horizontal and vertical emittances using a thin scatterer

    International Nuclear Information System (INIS)

    An isocentric superconducting rotating-gantry for heavy-ion therapy is being developed at NIRS. This rotating gantry can transport heavy ions having 430 MeV/u to an isocenter with irradiation angles of over ±180 degrees, and is further capable of performing fast raster-scanning irradiation. In the treatment using the rotating gantry, it is important to obtain a circular beam spot at the isocenter independent of the gantry angle. To accomplish this, we initially determined phase-space distributions of extracted beams from the HIMAC synchrotron ring, and further, matching of horizontal and vertical emittances using a thin scatterer was performed. We report results of the phase-space measurements as well as the emittance matching. (author)

  20. Electron Cloud at Low Emittance in CesrTA

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, Mark; /Cornell U., CLASSE; Alexander, James; /Cornell U., CLASSE; Billing, Michael; /Cornell U., CLASSE; Calvey, Joseph; /Cornell U., CLASSE; Conolly, Christopher; /Cornell U., CLASSE; Crittenden, James; /Cornell U., CLASSE; Dobbins, John; /Cornell U., CLASSE; Dugan, Gerald; /Cornell U., CLASSE; Eggert, Nicholas; /Cornell U., CLASSE; Fontes, Ernest; /Cornell U., CLASSE; Forster, Michael; /Cornell U., CLASSE; Gallagher, Richard; /Cornell U., CLASSE; Gray, Steven; /Cornell U., CLASSE; Greenwald, Shlomo; /Cornell U., CLASSE; Hartill, Donald; /Cornell U., CLASSE; Hopkins, Walter; /Cornell U., CLASSE; Kreinick, David; /Cornell U., CLASSE; Kreis, Benjamin; /Cornell U., CLASSE; Leong, Zhidong; /Cornell U., CLASSE; Li, Yulin; /Cornell U., CLASSE; Liu, Xianghong; /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /Cornell U., CLASSE /CERN /CERN /CERN /CERN /CERN /CERN; /more authors..

    2012-07-06

    The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud's effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results.