WorldWideScience

Sample records for cantilever cross-arch fixed

  1. Anterior Cantilever Resin-Bonded Fixed Dental Prostheses: A Review of the Literature.

    Science.gov (United States)

    Mourshed, Bilal; Samran, Abdulaziz; Alfagih, Amal; Samran, Ahalm; Abdulrab, Saleem; Kern, Matthias

    2018-03-01

    This review evaluated the survival rate of single retainer anterior resin-bonded fixed dental prostheses (RBFDPs) to determine whether the choice of material affects their clinical outcome. An electronic search of the English peer-reviewed dental literature in PubMed was conducted to identify all publications reporting on cantilever RBFDPs until May 2016. Study information extraction and methodological quality assessments were accomplished by two reviewers independently. The searched keywords were as follows: "resin-bonded, single retainer, all-ceramic resin-bonded fixed dental prostheses (RBFDPs), all-ceramic RBFDPs, cantilever resin, RBFDPs, cantilever resin-bonded bridge, two units cantilevered, two-unit cantilevered, metal-ceramic cantilever, and metal-ceramic." Furthermore, the ''Related Articles'' feature of PubMed was used to identify further references of interest within the primary search. The bibliographies of the obtained references were used to identify pertinent secondary references. Review articles were also used to identify relevant articles. After the application of exclusion criteria, the definitive list of articles was screened to extract the qualitative data, and the results were analyzed. Overall 2588 articles were dedicated at the first review phase; however, only 311 studies were left after the elimination of duplicates and unrelated studies. Seventeen studies passed the second review phase. Five studies were excluded because they were follow-up studies of the same study cohort. Twelve studies were finally selected. The use of cantilever RBFDPs showed promising results and high survival rates. © 2016 by the American College of Prosthodontists.

  2. The application of data measurement before the pedicle vertebral arch fixed operation with spiral CT

    International Nuclear Information System (INIS)

    Yang Zenian; Luo Zhongyao; Chen Yong'an

    2003-01-01

    Objective: Authors carry out volume scans and 3D surface reconstruction. Then authors get the precise data of pedicle of vertebral arch, entering nail angle on horizontal direction, entering nail screw length, and the smallest horizontal diameter and entering nails' distance on pedicle of vertebral arch before the pedicle vertebral arch fixed operation. Method: Select the axial image of the widest pedicle of vertebral arch and it SSD image, measure the entering nail distance on the pedicle of vertebral arch, TSA, entering nail screw length, and the smallest horizontal diameter of the pedicle of vertebral arch. Result: The method helps to prepare the length, size and location of the nail and TSA for the pedicle of vertebral arch fixed operation, increase the operation success rate. Conclusion: This is a simple and reliable method to prepare the precise data of the nail length and size, TSA for the operation

  3. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    LENUS (Irish Health Repository)

    Wang, Yan

    2010-01-01

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment.

  4. Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances.

    Science.gov (United States)

    Jian, Fan; Lai, Wenli; Furness, Susan; McIntyre, Grant T; Millett, Declan T; Hickman, Joy; Wang, Yan

    2013-04-30

    Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4. To assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Nine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one

  5. Orthodontic Traction of Impacted Canine Using Cantilever

    Directory of Open Access Journals (Sweden)

    Cláudia Nakandakari

    2016-01-01

    Full Text Available The impaction of the maxillary canines causes relevant aesthetic and functional problems. The multidisciplinary approach to the proper planning and execution of orthodontic traction of the element in question is essential. Many strategies are cited in the literature; among them is the good biomechanical control in order to avoid possible side effects. The aim of this paper is to present a case report in which a superior canine impacted by palatine was pulled out with the aid of the cantilever on the Segmented Arch Technique (SAT concept. A 14.7-year-old female patient appeared at clinic complaining about the absence of the upper right permanent canine. The proposed treatment prioritized the traction of the upper right canine without changing the occlusion and aesthetics. For this, it only installed the upper fixed appliance (Roth with slot 0.018, opting for SAT in order to minimize unwanted side effects. The use of cantilever to the traction of the upper right canine has enabled an efficient and predictable outcome, because it is of statically determined mechanics.

  6. Survival of anterior cantilevered all-ceramic resin-bonded fixed dental prostheses made from zirconia ceramic.

    Science.gov (United States)

    Sasse, Martin; Kern, Matthias

    2014-06-01

    This study evaluated the clinical outcome of all-ceramic resin-bonded fixed dental prostheses (RBFDPs) with a cantilevered single-retainer design made from zirconia ceramic. Forty-two anterior RBFDPs with a cantilevered single-retainer design were made from yttrium oxide-stabilized zirconium oxide ceramic. RBFDPs were inserted using Panavia 21 TC as luting agent after air-abrasion of the ceramic bonding surface. During a mean observation time of 61.8 months two debondings occurred. Both RBFDPs were rebonded using Panavia 21 TC and are still in function. A caries lesion was detected at one abutment tooth during recall and was treated with a composite filling. Therefore, the overall six-year failure-free rate according to Kaplan-Meier was 91.1%. If only debonding was defined as failure the survival rate increased to 95.2%. Since all RBFDPs are still in function the overall survival rate was 100% after six years. Cantilevered zirconia ceramic RBFDPs showed promising results within the observation period. Single-retainer resin-bonded fixed dental prostheses made from zirconia ceramic show very good mid-term clinical survival rates. They should therefore be considered as a viable treatment alternative for the replacement of single missing anterior teeth especially as compared to an implant therapy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    Science.gov (United States)

    Wang, Yan; Jian, Fan; Lai, Wenli; Zhao, Zhihe; Yang, Zhi; Liao, Zhengyu; Shi, Zongdao; Wu, Taixiang; Millett, Declan T; McIntyre, Grant T; Hickman, Joy

    2010-04-14

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. To identify and assess the evidence for the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (30th November 2009), CENTRAL (The Cochrane Library 2009, Issue 4), MEDLINE (1950 to 30th November 2009) and EMBASE (1980 to 30th November 2009). Reference lists of articles were also searched. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. Randomised controlled trials (RCTs) of initial arch wires to align crooked teeth with fixed orthodontic braces were selected. Only studies involving patients with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Seven RCTs, with 517 participants, provided data for this review. Among them, five trials investigated the speed of initial tooth alignment comparing: 0.016 inch ion-implanted A-NiTi wire versus 0.016 inch A-NiTi versus 0.0175 multistrand stainless steel wire; 0.016x0.022 inch medium force active M-NiTi wire versus 0.016x0.022 inch graded force active M-NiTi wire versus 0.0155 inch multistrand

  8. Concrete-Filled Steel Tube Arch Bridges in China

    Directory of Open Access Journals (Sweden)

    Jielian Zheng

    2018-02-01

    Full Text Available In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has been increasing rapidly, which is rare in the history of bridge development. The large-scale construction of expressways and high-speed railways demands the development of long-span arch bridges, and advances in design and construction techniques have made it possible to construct such bridges. In the present study, the current status, development, and major innovative technologies of CFST arch bridges and concrete arch bridges with a CFST skeleton in China are elaborated. This paper covers the key construction technologies of CFST arch bridges, such as the design, manufacture, and installation of steel tube arch trusses, the preparation and pouring of in-tube concrete, and the construction of the world’s longest CFST arch bridge—the First Hejiang Yangtze River Bridge. The main construction technologies of reinforced concrete arch bridges are also presented, which include cable-stayed fastening-hanging cantilever assembly, adjusting the load by means of stay cables, surrounding the concrete for arch rib pouring, and so forth. In addition, the construction of two CFST skeleton concrete arch bridges—the Guangxi Yongning Yong River Bridge and the Yunnan–Guangxi Railway Nanpan River Bridge—is discussed. CFST arch bridges in China have already gained a world-leading position; with the continuous innovation of key technologies, China will become the new leader in promoting the development of arch bridges. Keywords: Concrete-filled steel tube (CFST arch bridge, Steel-reinforced concrete arch bridge, Cable-stayed fastening-hanging cantilever assembly, Vacuum-assisted pouring in-tube concrete, Adjusting load by stay cables

  9. Implant-retained dentures for full-arch rehabilitation: a case report comparing fixed and removable restorations.

    Science.gov (United States)

    Zafiropoulos, Gregory-George; Hoffman, Oliver

    2011-01-01

    Dental implants as abutments for full-arch restorations are a well-documented treatment modality. This report presents a case in which the patient was treated initially with fixed restorations supported by either implants or natural teeth and subsequently treated with a removable implant/telescopic crown-supported overdenture. Advantages and disadvantages of each approach are described and discussed. While the fixed restoration resulted in a functionally satisfactory treatment outcome, the patient was displeased with the esthetic appearance. The main concern was the unnaturally long tooth shape necessary to compensate for the insufficient alveolar ridge height. Replacement of the existing restoration with an implant-supported removable overdenture led to a functionally and esthetically acceptable result. When deciding whether to use a fixed or removable implant-supported full-arch restoration, a multitude of factors must be considered. Due to the possible need for additional surgical steps to enhance the esthetic appearance surrounding fixed restorations, removable implant-supported partial dentures often are the better choice.

  10. Effects of Cement, Abutment Surface Pretreatment, and Artificial Aging on the Force Required to Detach Cantilever Fixed Dental Prostheses from Dental Implants.

    Science.gov (United States)

    Kappel, Stefanie; Chepura, Taras; Schmitter, Marc; Rammelsberg, Peter; Rues, Stefan

    To examine the in vitro effects of different cements, abutment surface preconditioning, and artificial aging on the maximum tensile force needed to detach cantilever fixed dental prostheses (FDPs) from dental implants with titanium abutments. A total of 32 tissue-level implants were combined with standardized titanium abutments. For each test group, eight cantilever FDPs were fabricated using selective laser melting (cobalt-chromium [CoCr] alloy). The inner surfaces of the cantilever FDPs and half of the abutments were sandblasted and then joined by use of four different cements (two permanent and two semi-permanent) in two different amounts per cement. Subgroups were tested after either artificial aging (thermocycling and chewing simulation) or 3 days of water storage. Finally, axial pull off-tests were performed for each abutment separately. Cement type and surface pretreatment significantly affected decementation behavior. The highest retention forces (approximately 1,200 N) were associated with sandblasted abutments and permanent cements. With unconditioned abutments, temporary cements (Fu cement (Fu ≈ 100 N), resulted in rather low retention forces. Zinc phosphate cement guaranteed high retention forces. After aging, retention was sufficient only for cementation with zinc phosphate cement and for the combination of sandblasted abutments and glass-ionomer cement. When glass-ionomer cement is used to fix cantilever FDPs on implants, sandblasting of standard titanium abutments may help prevent loss of retention. Retention forces were still high for FDPs fixed with zinc phosphate cement, even when the abutments were not pretreated. Use of permanent cements only, however, is recommended to prevent unwanted loosening of cantilever FDPs.

  11. Fifteen-year survival of anterior all-ceramic cantilever resin-bonded fixed dental prostheses.

    Science.gov (United States)

    Kern, Matthias

    2017-01-01

    The aim of this follow-up study was to report the long-term outcome of all-ceramic cantilever resin-bonded fixed dental prostheses (RBFDPs). In 16 patients (mean age of 33.3±17.5years) 22 RBFDPs made from a glass-infiltrated alumina ceramic (In-Ceram) were inserted with a phosphate monomer containing luting agent after air-abrasion of the retainer wings. The abutment preparation included a shallow groove on the cingulum and a small proximal box. The restorations replacing 16 maxillary and 6 mandibular incisors were followed over a mean observation time of 188.7 months. No restoration debonded. Two RBFDPs fractured and were lost 48 and 214 months after insertion, respectively. The 10-year and 15-year survival rates were both 95.4% and dropped to 81.8% after 18 years. Anterior all-ceramic cantilever RBFDPs exhibited an excellent clinical longevity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    Science.gov (United States)

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. The Metal-Zirconia Implant Fixed Hybrid Full-Arch Prosthesis: An Alternative Technique for Fabrication.

    Science.gov (United States)

    Stumpel, Lambert J; Haechler, Walter

    2018-03-01

    The metal-resin hybrid full-arch prosthesis has been a traditionally used type of restoration for full-arch implant fixed dentures. A newer development has centered around the use of monolithic zirconia or zirconia veneered with porcelain. Being a ceramic, zirconia has the potential for fracture. This article describes a technique that utilizes a metal substructure to support a chemically and mechanically resinbonded shell of zirconia. The workflow is discussed, ranging from in-office master cast fabrication to the CAD/ CAM production of the provisional and the definitive metal-zirconia prosthesis. The article also highlights the advantages and disadvantages of various materials used for hybrid prostheses.

  14. Alignment Strategy for Constricted Maxillary Dental Arch in Patients With Unilateral Cleft Lip and Palate Using Fixed Orthodontic Appliance.

    Science.gov (United States)

    Park, Yoon-Hee; Park, Sumin; Baek, Seung-Hak

    2018-03-01

    The purpose of this study was to compare the alignment pattern of the constricted maxillary dental arch by fixed orthodontic treatment (FOT) in the well-aligned and constricted arches of unilateral cleft lip and palate (UCLP) patients. 19 UCLP patients were divided into Group 1 (well-aligned arch, n = 9) and Group 2 (constricted arch, n = 10). After the cephalometric and maxillary dental arch variables before (T1) and after FOT (T2) were measured, statistical analysis was performed. There were no significant differences in the surgical timing of cheiloplasty, palatoplasty, and secondary alveolar bone grafting and in the surgical method of cheiloplasty between the 2 groups. However, Group 2 had a higher percentage of palatoplasty method, which could leave the denuded bone for secondary healing than Group 1 (P dental arch compared to Group 1 at the T1 stage (inter-second premolar width, greater segment angle [GSA], and lesser segment angle [LSA], all P dental arch shape, different strategy is necessary to obtain proper alignment by FOT.

  15. Differences in the Microbial Colonization Among Arch Wire Types, Gauges and Cross Sections

    Directory of Open Access Journals (Sweden)

    Reem A. Rafeeq

    2018-02-01

    Full Text Available Background: The presence of orthodontic materials in the oral cavity represent a unique surface that can interact with bacteria, leading to pathogenic plaque formation and subsequent enamel demineralization, Streptococcus mutans play an important role in the initiation and progression of dental caries and they are considered the primary cause of bacteriological caries. The objective of this study was to investigate the effect of multiple factors including the type of arch wire, salivary coating, cross section, and wire thickness on the levels of mutans streptococci adherence. Materials and Methods: Two types of arch wire stainless steel and nickel titanium were selected using the following criteria: round and rectangular with gauges 0.014, 0.018, 0.016 × 0.022 and 0.019 × 0.0 25 inches which were subdivided into eight groups. Bacterial adhesion was quantified by a microbial culture technique and the number of adhesive bacteria were analyzed and counted after growth in culture for each group with and without saliva coating at 15 and 60 minutes. Detection of mutans streptococci by saliva-check Mutans test. Results: There was a significant difference between arch wire types in each time interval and the highest bacterial adhesion on the NiTi arch wires with rectangular cross section in the absence of saliva with extended incubation time. Conclusions: The adherence of mutans streptococci in saliva coated wires seems to be low. At increased incubation time, rectangular cross section arch wire showed an increased number of adhering bacteria with less effect on different gauges of the arch wire.

  16. Performance of zirconia ceramic cantilever fixed dental prostheses: 3-year results from a prospective, randomized, controlled pilot study.

    Science.gov (United States)

    Zenthöfer, Andreas; Ohlmann, Brigitte; Rammelsberg, Peter; Bömicke, Wolfgang

    2015-07-01

    Little is known about the clinical performance of ceramic cantilever fixed dental prostheses on natural teeth. The purpose of this randomized controlled pilot study was to evaluate the clinical performance of ceramic and metal ceramic cantilever fixed dental prostheses (CFDPs) after 3 years of service. Twenty-one participants were randomly allocated to 2 treatment groups. Participants in the ceramic (ZC) group (n=11) each received 1 CFDP made of yttria-stabilized, tetragonal zirconia polycrystal; the others (n=10) were fitted with a metal ceramic (MC) CFDP. All CFDPs were retained by 2 complete crown abutments and replaced 1 tooth. The clinical target variables were survival, incidence of complications, probing pocket depth (PPD), probing attachment level (PAL), plaque index (PI), gingival index (GI), and esthetic performance as rated by the participants. The United States Public Health Service (USPHS) criteria were used to evaluate chipping, retention, color, marginal integrity, and secondary caries. Descriptive statistics and nonparametric analyses were applied to the target variables in the 2 groups. The esthetic performance of the CFDPs was also visualized by using a pyramid comparison. The overall survival of the CFDPs was 100% in both groups. During the 3-year study, 6 clinically relevant complications requiring aftercare were observed among 5 participants (4 in the ZC group and 2 in the MC group). Changes in the PI, GI, PPD, and PAL of the abutment teeth were similar for both groups (P>.05). The participants regarded the esthetic performance of ZC-CFDPs and MC-CFDPs as satisfactory. Within the 3-year observation period, the clinical performance of MC-FDPs and ZC-FDPs was acceptable. More extensive research with larger sample sizes is encouraged, however, to confirm the evaluation of the survival of Y-TZP hand-veneered cantilever FPDs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. [Extension of (extremely) shortened dental arches by fixed or removable partial dentures

    NARCIS (Netherlands)

    Witter, D.J.; Hoefnagel, R.A.; Snoek, P.A.; Creugers, N.H.J.

    2009-01-01

    Whether a shortened dental arch needs to be extended depends on the degree of the shortening. Four categories of shortened dental arches can be distinguished: 1. slightly shortened dental arches; 2. moderately shortened dental arches; 3. extremely shortened dental arches; and 4. asymmetrical

  18. A modified, lingually supported cantilevered Herbst appliance.

    Science.gov (United States)

    Snodgrass, D

    1996-01-01

    This new, fixed-functional appliance/Herbst/Bioprogressive system is designed for patient comfort and mandatory compliance. It also combines the positive clinical effects of four fixed-functional systems. It allows rapid palatal expansion of the upper arch, alveolar uprighting of the lower arch, upper and lower incisor alignment, and sagittal correction of Class II malocclusions to occur simultaneously with one appliance fixed in both arches. It is indicated for use in growing patients with skeletal Class II malocclusions. The ideal timing for treatment is the late mixed dentition. Being able to remove the appliance after one year with the upper second bicuspids erupting slightly Class III so the clinician can immediately begin fixed finishing mechanics would be ideal. This new Herbst design will reduce the frequency of orthognathic surgery and upper bicuspid extraction to camouflage Class II malocclusions. At the same time, it gives total control to the clinician in treating some more difficult, non-compliant patients. Fixed-functional appliances, which improve treatment efficiency and treatment results and provide for patient comfort, while at the same time give the treating clinician almost total control of the three planes of facial growth will open new doors for orthodontic treatment and research in the next century.

  19. [Influence of retainer design on fixation strength of resin-bonded glass fiber reinforced composite fixed cantilever dentures].

    Science.gov (United States)

    Petrikas, O A; Voroshilin, Iu G; Petrikas, I V

    2013-01-01

    Fiber-reinforced composite (FRC) fixed partial dentures (FPD) have become an accepted part of the restorative dentist's armamentarium. The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass FRC-FPDs. Four retainer designs were tested: a dual wing, a dual wing + horizontal groove, a dual wing + occlusal rest and a step-box. Of each design on 7 human mandibular molars, FRC-FPDs of a premolar size were produced. The FRC framework was made of resin Revolution (Kerr) impregnated glass fibers (GlasSpan, GlasSpan) and veneered with hybrid resin composite (Charisma, Kulzer). Revolution (Kerr) was used as resin luting cement. FRC-FPDs were loaded to failure in a universal testing machine. T (Student's)-test was used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FPDs (step-box: 172±11 N) compared to wing-retained FPDs (poptimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FPDs.

  20. The effects of loading on the preload and dimensions of the abutment screw for a 3-unit cantilever-fixed prosthesis design.

    Science.gov (United States)

    Setia, Gaurav; Yousef, Hoda; Ehrenberg, David; Luke, Allyn; Weiner, Saul

    2013-08-01

    The purpose of this study was to use an in vitro model system to compare the effects on the screw torque and screw dimensions within 2 commercially available implant systems from occlusal loading on a cantilevered-fixed partial denture. Cantilevered implant-supported 3-unit prostheses with 2 premolar abutments and 1 premolar pontic (7.3 mm in length) were made on resin casts containing 2 implant analogs for 2 implant systems: BioLok Silhouette Tapered Implant System (Birmingham, AL) and Zimmer Tapered Screw-Vent Implant System (Carlsbad, CA) with 10 samples in each group. Each sample was loaded with either of 2 protocols: (1) a load of 50 N on the cantilevered pontic unit and (2) a loading of 150 N on all 3 units. The outcome measures were (1) changes in residual torque of the abutment screws and (2) changes in screw dimension. The BioLok Silhouette Tapered Implant group demonstrated slight but statistically significant torque loss 18.8% to 28.5% in both abutment screws for both protocols, P ≤ 0.05, without any changes in screw dimension. In the Zimmer Tapered Screw-Vent Implant group, there was a significant elongation of the abutment screws and a markedly significant 44.4%, (P ≤ 0.01) loss in torque in the mesial screw and a 28.5%, (P ≤ 0.05) loss in torque in the distal screw when the cantilever alone was loaded. Differences in screw design influence the maintenance of preload and distortion of the shank. The influence of the interface design, namely an internal hex of 1 mm versus an external hex did not influence the preload. Cantilevered prostheses can cause loss of torque and dimensional changes in abutment screws.

  1. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  2. Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study.

    Science.gov (United States)

    Gonçalves, Fernanda de Cássia Papaiz; Amaral, Marina; Borges, Alexandre Luiz Souto; Gonçalves, Luiz Fernando Martins; Paes-Junior, Tarcisio José de Arruda

    2018-04-01

    Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Double aortic arch

    Science.gov (United States)

    Surgery can be done to fix double aortic arch. The surgeon ties off the smaller branch and separates it from the larger branch. Then the surgeon closes the ends of the aorta with stitches. This relieves pressure on the esophagus and windpipe.

  4. Three-dimensional finite element analysis of zirconia all-ceramic cantilevered fixed partial dentures with different framework designs.

    Science.gov (United States)

    Miura, Shoko; Kasahara, Shin; Yamauchi, Shinobu; Egusa, Hiroshi

    2017-06-01

    The purpose of this study were: to perform stress analyses using three-dimensional finite element analysis methods; to analyze the mechanical stress of different framework designs; and to investigate framework designs that will provide for the long-term stability of both cantilevered fixed partial dentures (FPDs) and abutment teeth. An analysis model was prepared for three units of cantilevered FPDs that assume a missing mandibular first molar. Four types of framework design (Design 1, basic type; Design 2, framework width expanded buccolingually by 2 mm; Design 3, framework height expanded by 0.5 mm to the occlusal surface side from the end abutment to the connector area; and Design 4, a combination of Designs 2 and 3) were created. Two types of framework material (yttrium-oxide partially stabilized zirconia and a high precious noble metal gold alloy) and two types of abutment material (dentin and brass) were used. In the framework designs, Design 1 exhibited the highest maximum principal stress value for both zirconia and gold alloy. In the abutment tooth, Design 3 exhibited the highest maximum principal stress value for all abutment teeth. In the present study, Design 4 (the design with expanded framework height and framework width) could contribute to preventing the concentration of stress and protecting abutment teeth. © 2017 Eur J Oral Sci.

  5. A systematic review of prosthetic restoration in patients with shortened dental arches

    Directory of Open Access Journals (Sweden)

    Kenji Fueki

    2011-08-01

    Full Text Available The literature regarding the effect of prosthetic restoration in patients having distal extension edentulous space in posterior area (shortened dental arch: SDA is reviewed in the following article. Information retrieval followed a systematic approach using PubMed. Articles in English published between 1966 and March 2011 describing the outcome of treatment with various prostheses were evaluated. From the search results of 98 articles, 21 articles met the inclusion criteria. Treatment with removable partial dentures (RPDs improved masticatory function, patient satisfaction and oral health-related quality of life (OHRQoL. However, no significant difference was found in the outcomes between patients with RPDs and with cantilever fixed partial dentures (CFPDs. Caries developed more frequently after treatment with RPDs than CFPDs. The time to survival for CFPDs was not longer than that for RPDs, while more visits to maintain RPDs were required than for CFPDs. No significant difference was found in masticatory function, OHRQoL, and occlusal stability between patients with RPDs and those without restoration of missing molars. Consequently, treatment with RPDs for SDA seems to be less advantageous than CFPDs or no restoration for missing molars. Further research is required to validate treatment with implant-supported fixed partial dentures for SDA.

  6. The effect of rotatory inertia on the dynamic response of cantilever structures

    International Nuclear Information System (INIS)

    Lin, Y.J.; Hadjian, A.H.

    1977-01-01

    For the dynamic response of cantilever beams, the error introduced by the bending theory becomes significant as the ratio of the radius of gyration to the beam length (r/l), exceeds 0.1. In this case, the use of Timoshenko's beam equation becomes more appropriate. This equation includes, in addition to the bending effects, both shear deformation and rotatory inertia effects. In the discrete modeling of beam elements, both the shear deformation and rotatory inertia terms play roles in the mass matrix, while only the shear deformation terms appear in the stiffness matrix. The effect of rotatory inertia on the frequencies and dynamic response of cantilever structures subjected to lateral earthquake excitation is thoroughly studied. This is done by using both the consistent and lumped mass matrices and analytical solution. The beam support is treated either as fixed or elastically restrained to consider soil-structure interaction effects. Since containment structures can be treated as hollow beams, the cantilever beam of uniform cross-section is examined first. For those cases where the ratio of the radius of gyration to beam length lies within the range of interest, all the solutions show that rotatory inertia has an important impact on both the frequencies (other than that of the fundamental mode) and the vertical component of the response. However, as the soil-structure interaction effects become significant rotatory inertia effects become secondary. For shear wall structures used in nuclear power plants, the floors may be treated as rigid diaphragms and the shear walls between floors are usually considered to be beam elements of uniform cross-section

  7. Piezoelectric cantilever sensors

    Science.gov (United States)

    Shih, Wan Y. (Inventor); Shih, Wei-Heng (Inventor); Shen, Zuyan (Inventor)

    2008-01-01

    A piezoelectric cantilever with a non-piezoelectric, or piezoelectric tip useful as mass and viscosity sensors. The change in the cantilever mass can be accurately quantified by monitoring a resonance frequency shift of the cantilever. For bio-detection, antibodies or other specific receptors of target antigens may be immobilized on the cantilever surface, preferably on the non-piezoelectric tip. For chemical detection, high surface-area selective absorbent materials are coated on the cantilever tip. Binding of the target antigens or analytes to the cantilever surface increases the cantilever mass. Detection of target antigens or analytes is achieved by monitoring the cantilever's resonance frequency and determining the resonance frequency shift that is due to the mass of the adsorbed target antigens on the cantilever surface. The use of a piezoelectric unimorph cantilever allows both electrical actuation and electrical sensing. Incorporating a non-piezoelectric tip (14) enhances the sensitivity of the sensor. In addition, the piezoelectric cantilever can withstand damping in highly viscous liquids and can be used as a viscosity sensor in wide viscosity range.

  8. Fracture strength of fiber-reinforced surface-retained anterior cantilever restorations

    NARCIS (Netherlands)

    Oezcan, Mutlu; Kumbuloglu, Ovul; User, Atilla

    2008-01-01

    Purpose: This study compared the fracture strength of direct anterior cantilever fiber-reinforced composite (FRC) fixed partial dentures (FPD) reinforced with 3 types of E-glass fibers preimpregnated with either urethane tetramethacrylate, bisphenol glycidylmethacrylate/polymethyl methacrylate, or

  9. Multi-objective optimization of an arch dam shape under static loads using an evolutionary game method

    Science.gov (United States)

    Meng, Rui; Cheong, Kang Hao; Bao, Wei; Wong, Kelvin Kian Loong; Wang, Lu; Xie, Neng-gang

    2018-06-01

    This article attempts to evaluate the safety and economic performance of an arch dam under the action of static loads. The geometric description of a crown cantilever section and the horizontal arch ring is presented. A three-objective optimization model of arch dam shape is established based on the arch dam volume, maximum principal tensile stress and total strain energy. The evolutionary game method is then applied to obtain the optimal solution. In the evolutionary game technique, a novel and more efficient exploration method of the game players' strategy space, named the 'sorting partition method under the threshold limit', is presented, with the game profit functions constructed according to both competitive and cooperative behaviour. By way of example, three optimization goals have all shown improvements over the initial solutions. In particular, the evolutionary game method has potentially faster convergence. This demonstrates the preliminary proof of principle of the evolutionary game method.

  10. Is it possible to use cross-sectional and vertical facial measurements to establish the shape of the mandibular arch?

    Science.gov (United States)

    El Haje, Ossam Abu; Pompeo, Daniela Daufenback; Furtado, Gisela Crippa; Rivera, Luciana Monti Lima; Paranhos, Luiz Renato

    2014-11-01

    Given the benefits of radiographic cephalometric studies in determining patterns of dental-skeletal-facial normality in orthodontics, the aim of this study was to investigate the association between mandibular dental arch shape and cross-sectional and vertical facial measurements. It was analyzed plaster casts and teleradiographs in frontal and lateral norm belonging to 50 individuals, aged between 15 and 19 years, with no previous history of orthodontic treatment and falling into four of the six Andrews's occlusion keys. The plaster models were scanned (3D) and the images of the dental arches were classified subjectively as oval, triangular and quadrangular by three calibrated examiners, with moderate inter-examiner agreement (Kappa = 0.50). After evaluation of the method error by paired t test (p > 0.05), it was carried out the analysis of cross-sectional and vertical facial measurements to be compared to the shape of the dental arch. Data were subjected to one-way analysis of variance with a significance level of 5%. When the VERT index was compared with the three arch shapes, no measurement showed statistically significant differences (p > 0.05): triangular (0.54); oval (0.43); and quadrangular (0.73); as well as there were no differences (p > 0.05) in the widths of the face (141.20; 141.26; 143.27); maxilla (77.27; 77.57; 78.59) and mandible (105.13; 103.96; 104.28). It can be concluded that there was no correlation between different shapes of the mandibular dental arch and the cross-sectional and vertical facial measurements investigated.

  11. Two-unit cantilevered resin-bonded fixed partial denture as a substitute for a prosthodontic-orthodontic treatment plan: a 5-year case report.

    Science.gov (United States)

    Emami, Elham; St-Georges, Annie; de Grandmont, Pierre

    2012-01-01

    In this case report, we describe the successful long-term treatment of a patient with dental agenesis. The initial treatment plan included an orthodontic phase to provide adequate space for replacing missing lateral incisors with implants. However, because of some complications encountered after 2 years of orthodontic treatment, a revised treatment plan was considered to achieve functional and esthetic goals. The patient was completely satisfied 5 years after being treated with two 2-unit cantilevered resin-bonded fixed partial dentures supported by the cuspids. This conservative treatment plan was cost-effective without having any significant biological cost.

  12. The Correlated Dynamics of Micron-Scale Cantilevers in a Viscous Fluid

    Science.gov (United States)

    Robbins, Brian A.

    object yielded newly observed features and characteristics. It is shown that the curve shape of the cross-correlation of the displacement of the mass of the tethered object is similar to that of the auto-correlation of the displacement of the mass representing a step forced cantilever. The cross-correlation of the displacement of the mass of the tethered object, however, is found to be significantly more dependent on the stiffness ratio than the auto-correlation of the displacement of the mass representing a cantilever for t > 0. At t = 0, it is observed that the mass of the tethered object yields the same finite value for the cross-correlation for all studied values of the stiffness ratio. This characteristic is a result of the symmetry of the studied spring-mass system.

  13. Right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch

    International Nuclear Information System (INIS)

    Ahn, Kyung-Sik; Yong, Hwan Seok; Woo, Ok Hee; Kang, Eun-Young; Lee, Joo-Won

    2007-01-01

    We present a rare case of right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch. A 7-month-old boy presented with a cardiac murmur. Cardiac situs was normal and there was no evidence of an intracardiac shunt or patent ductus arteriosus. MR aortography revealed a right aortic arch that was high-positioned, tortuous and narrowed. This right aortic arch crossed the midline behind the oesophagus and continued as a left-sided descending aorta. The left common carotid and subclavian arteries arose from a large branching vascular structure that derived from the top of the left-sided descending aorta. The right common carotid artery arose from the ascending aorta. The proximal portion of the right common carotid artery showed very severe stenosis and poststenotic dilatation. The right subclavian artery originated distal to the narrowed and tortuous segment of the aortic arch. (orig.)

  14. Pembuatan Cantilever Bridge Anterior Rahang Atas sebagai Koreksi Estetik

    Directory of Open Access Journals (Sweden)

    Yusrina Sumartati

    2012-12-01

    Full Text Available Latar belakang. Kehilangan gigi anterior rahang atas mengakibatkan gangguan fungsi fonetik dan estetik. Gangguan fungsi estetik menyebabkan pasie menjadi rendah diri. Kondisi ini dapat diatasi oleh dokter gigi, salah satunya dengan pembuatan cantilever bridge. Tujuan. Penulisan ini yaitu untuk memberi informasi bahwa pada kasus kehilangan gigi-gigi anterior rahang atas dengan space yang telah menyempit dan malposisi gigi dapat dibuatkan protesa berupa gigi tiruan cekat dengan desain cantilever bridge. Kasus dan perawatan. Laporan kasus ini membahas tentang pasien perempuan umur 39 tahun yang datang ke Rumah Sakit Gigi dan Mulut Prof. Soedomo, dengan keluhan merasa kurang percaya diri karena gigi depan rahang atas hilang sejak 5 tahun yang lalu akibat kecelakaan. Gigi-gigi anterior rahang atas yang masih ada mengalami malposisi akibat pemakaian gigi tiruan sebagian lepasan yang tidak baik. Perawatan yang dilakukan adalah dengan pembuatan cantilever bridge pada gigi 11, 12, 13 dan 21, 22, 23. Kesimpulan. Gangguan fungsi estetik pada gigi anterior rahang atas dapat diatasi dengan pembuatan cantilever bridge.   Background. Maxillary anteriortooth loss resulting in impaired function of phonetic and aesthetic. Impaired function of aesthetic cause patients to become self conscious. This condition can be treated by a dentist, one with a cantilever bridge. Purpose. To inform that in case of missing anterior teeth of the upper jaw with a space that has been narrowed, and malposition of teeth can be made prosthesis denture fixed bridge with a cantilever design. Case and treatment. This case report discusses the 39 years old female patient who came to he Dental Hospital Prof. Soedomo, with complaints of feeling less confident due to the maxillary front teeth missing since 5 years ago due to an accident. Anterior teeth of the upper jaw are still experiencing malposition due to the use of removable partial dentures are not good. The treatment is done is by

  15. Energy harvesting from the interaction of a Lamb dipole with a flexible cantilever

    Science.gov (United States)

    Tang, Hui; Wang, Chenglei

    2017-11-01

    Energy harvesting from interactions of coherent flow structures with flexible solid structures can be used for powering miniature electronic devices. Although effective, the fundamental mechanism of such an energy extraction process has not been fully understood. Therefore, this study aims to provide more physical insights into this problem. The coherent flow structure is represented by a Lamb dipole, and the solid structure is assumed as a two-dimensional flexible cantilever. The cantilever is placed along the propagation direction of the dipole, with its fixed end initially towards or away from the dipole and its lateral distance from the dipole center varied. As the dipole passes through the cantilever, the latter can extract energy from the former through effective interactions. Such a two-dimensional fluid-structure interaction problem is numerically studied at a low Reynolds number of 200 using a lattice Boltzmann method (LBM) based numerical framework. The simulation results reveal that the flexible cantilever with a moderate stiffness is more beneficial to the energy harvesting, and it can scavenge more energy from the ambient vortices when its fixed end is initially away from the dipole with a relatively small lateral distance. The authors gratefully acknowledge the financial support for this study from the Research Grants Council of Hong Kong under General Research Fund (Project No. PolyU 152493/16E).

  16. Measurement of Mechanical Properties of Cantilever Shaped Materials

    Directory of Open Access Journals (Sweden)

    Thomas Thundat

    2008-05-01

    Full Text Available Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM due to their extremely high sensitivity in measuring surface forces. The versatility of these probes, however, allows the sensing and measurement of a host of mechanical properties of various materials. Sensor parameters such as resonance frequency, quality factor, amplitude of vibration and bending due to a differential stress can all be simultaneously determined for a cantilever. When measuring the mechanical properties of materials, identifying and discerning the most influential parameters responsible for the observed changes in the cantilever response are important. We will, therefore, discuss the effects of various force fields such as those induced by mass loading, residual stress, internal friction of the material, and other changes in the mechanical properties of the microcantilevers. Methods to measure variations in temperature, pressure, or molecular adsorption of water molecules are also discussed. Often these effects occur simultaneously, increasing the number of parameters that need to be concurrently measured to ensure the reliability of the sensors. We therefore systematically investigate the geometric and environmental effects on cantilever measurements including the chemical nature of the underlying interactions. To address the geometric effects we have considered cantilevers with a rectangular or circular cross section. The chemical nature is addressed by using cantilevers fabricated with metals and/or dielectrics. Selective chemical etching, swelling or changes in Young’s modulus of the surface were investigated by means of polymeric and inorganic coatings. Finally to address the effect of the environment in which the cantilever operates, the Knudsen number was determined to characterize the molecule-cantilever collisions. Also bimaterial cantilevers with high thermal sensitivity were used to discern the effect of temperature

  17. Chemical sensor with oscillating cantilevered probe

    Science.gov (United States)

    Adams, Jesse D

    2013-02-05

    The invention provides a method of detecting a chemical species with an oscillating cantilevered probe. A cantilevered beam is driven into oscillation with a drive mechanism coupled to the cantilevered beam. A free end of the oscillating cantilevered beam is tapped against a mechanical stop coupled to a base end of the cantilevered beam. An amplitude of the oscillating cantilevered beam is measured with a sense mechanism coupled to the cantilevered beam. A treated portion of the cantilevered beam is exposed to the chemical species, wherein the cantilevered beam bends when exposed to the chemical species. A second amplitude of the oscillating cantilevered beam is measured, and the chemical species is determined based on the measured amplitudes.

  18. Transition from failing dentition to full-arch fixed implant-supported prosthesis with a staged approach using removable partial dentures: a case series.

    Science.gov (United States)

    Cortes, Arthur Rodriguez Gonzalez; Cortes, Djalma Nogueira; No-Cortes, Juliana; Arita, Emiko Saito

    2014-06-01

    The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full-arch fixed implant-supported prosthesis may be inserted. Eight patients, who had undergone maxillary full-arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow-up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line. © 2013 by the American College of Prosthodontists.

  19. 〈c + a〉 Dislocations in deformed Ti–6Al–4V micro-cantilevers

    International Nuclear Information System (INIS)

    Ding, Rengen; Gong, Jicheng; Wilkinson, Angus J.; Jones, Ian P.

    2014-01-01

    Single α–β colony micro-cantilevers with an equilateral triangular cross-section and an apex at the bottom were machined from a polycrystalline commercial Ti–6Al–4V sample using a focused ion beam (FIB). Each cantilever contained several α lamellae separated by thin fillets of β. A nano-indenter was used to perform micro-bending tests (Ding et al., 2012) [1]. 〈c + a〉 Slip systems were selectively activated in the cantilevers by controlling the crystal direction along the micro-cantilever to be [0 0 0 1]. Specimens for transmission electron microscopy were prepared from the deformed micro-cantilevers using a dual-beam FIB. Bright field scanning transmission electron microscopy was used to investigate the processes of slip nucleation, propagation and transmission through the α/β interface. Dislocations initiate first near the bottom of the cantilever and subsequently from the top. Both sets of dislocations move inward toward the neutral axis. Planar pyramidal {101 ¯ 1} slip was observed at the top (tension) but cross-slip was observed at the bottom (compression). All the 〈c + a〉 slip systems are equally stressed, but only a limited number is activated. This is tentatively interpreted in terms of dislocation transmission through the β fillets

  20. Spring constant calibration of atomic force microscope cantilevers of arbitrary shape

    Energy Technology Data Exchange (ETDEWEB)

    Sader, John E. [Department of Mathematics and Statistics, University of Melbourne, Victoria 3010 (Australia); Kavli Nanoscience Institute and Department of Physics, California Institute of Technology, Pasadena, California 91125 (United States); Sanelli, Julian A.; Adamson, Brian D.; Bieske, Evan J. [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); Monty, Jason P.; Marusic, Ivan [Department of Mechanical Engineering, University of Melbourne, Victoria 3010 (Australia); Wei Xingzhan; Mulvaney, Paul [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); Bio21 Institute, University of Melbourne, Victoria 3010 (Australia); Crawford, Simon A. [School of Botany, University of Melbourne, Victoria 3010 (Australia); Friend, James R. [Melbourne Centre for Nanofabrication, Clayton, Victoria 3800 (Australia); MicroNanophysics Research Laboratory, RMIT University, Melbourne, Victoria 3001 (Australia)

    2012-10-15

    The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.

  1. Spring constant calibration of atomic force microscope cantilevers of arbitrary shape

    International Nuclear Information System (INIS)

    Sader, John E.; Sanelli, Julian A.; Adamson, Brian D.; Bieske, Evan J.; Monty, Jason P.; Marusic, Ivan; Wei Xingzhan; Mulvaney, Paul; Crawford, Simon A.; Friend, James R.

    2012-01-01

    The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.

  2. A capacitive power sensor based on the MEMS cantilever beam fabricated by GaAs MMIC technology

    Science.gov (United States)

    Yi, Zhenxiang; Liao, Xiaoping

    2013-03-01

    In this paper, a novel capacitive power sensor based on the microelectromechanical systems (MEMS) cantilever beam at 8-12 GHz is proposed, fabricated and tested. The presented design can not only realize a cantilever beam instead of the conventional fixed-fixed beam, but also provide fine compatibility with the GaAs monolithic microwave integrated circuit (MMIC) process. When the displacement of the cantilever beam is very small compared with the initial height of the air gap, the capacitance change between the measuring electrode and the cantilever beam has an approximately linear dependence on the incident radio frequency (RF) power. Impedance compensating technology, by modifying the slot width of the coplanar waveguide transmission line, is adopted to minimize the effect of the cantilever beam on the power sensor; its validity is verified by the simulation of high frequency structure simulator software. The power sensor has been fabricated successfully by Au surface micromachining using polyimide as the sacrificial layer on the GaAs substrate. Optimization of the design with impedance compensating technology has resulted in a measured return loss of less than -25 dB and an insertion loss of around 0.1 dB at 8-12 GHz, which shows the slight effect of the cantilever beam on the microwave performance of this power sensor. The measured capacitance change starts from 0.7 fF to 1.3 fF when the incident RF power increases from 100 to 200 mW and an approximate linear dependence has been obtained. The measured sensitivities of the sensor are about 6.16, 6.27 and 6.03 aF mW-1 at 8, 10 and 12 GHz, respectively.

  3. Neonatal aortic arch reconstruction avoiding circulatory arrest and direct arch vessel cannulation.

    Science.gov (United States)

    Tchervenkov, C I; Korkola, S J; Shum-Tim, D; Calaritis, C; Laliberté, E; Reyes, T U; Lavoie, J

    2001-11-01

    Aortic arch reconstruction in neonates routinely requires deep hypothermic circulatory arrest. We reviewed our experience with techniques of continuous low-flow cerebral perfusion (LFCP) avoiding direct arch vessel cannulation. Eighteen patients, with a median age of 11 days (range 1 to 85 days) and a mean weight of 3.2 +/- 0.8 kg, underwent aortic arch reconstruction with LFCP. Seven had biventricular repairs with arch reconstruction, 9 underwent the Norwood operation and 2 had isolated arch repairs. In 1 Norwood and 7 biventricular repair patients, LFCP was maintained by advancing the cannula from the distal ascending aorta into the innominate artery. In 8 of 9 Norwood patients, LFCP was maintained by directing the arterial cannula into the pulmonary artery confluence and perfusing the innominate artery through the right modified Blalock-Taussig shunt fully constructed before cannulation for cardiopulmonary bypass. In 2 patients requiring isolated arch reconstruction, the ascending aorta was cannulated and the cross-clamp was applied just distal to the innominate artery. LFCP was maintained at 0.6 +/- 0.2 L x min(-1) x m(-2) for 41.0 +/- 13.9 minutes at 18.5 degrees C +/- 1.1 degrees C. In 10 of the 18 patients, blood pressure during LFCP was 15 +/- 8 mm Hg remote from the innominate artery (left radial, umbilical or femoral arteries). In 8 of the 18 patients, right radial pressure during LFCP was 24 +/- 10 mm Hg. The mean mixed-venous saturation was 79.8% +/- 10% during LFCP. Two patients had preoperative seizures, whereas none had seizures postoperatively. One patient died. Neonatal aortic arch reconstruction is possible without circulatory arrest or direct arch vessel cannulation. These techniques maintained adequate mixed-venous oxygen saturations with no associated adverse neurologic outcomes.

  4. Dental arch changes associated with rapid maxillary expansion: A retrospective model analysis study

    Directory of Open Access Journals (Sweden)

    Ivor M D′Souza

    2015-01-01

    Full Text Available Introduction: Transverse deficiency of the maxilla is a common clinical problem in orthodontics and dentofacial orthopedics. Transverse maxillary deficiency, isolated or associated with other dentofacial deformities, results in esthetic and functional impairment giving rise to several clinical manifestations such as asymmetrical facial growth, positional and functional mandibular deviations, altered dentofacial esthetics, adverse periodontal responses, unstable dental tipping, and other functional problems. Orthopedic maxillary expansion is the preferred treatment approach to increase the maxillary transverse dimension in young patients by splitting of the mid palatal suture. This orthopedic procedure has lately been subject of renewed interest in orthodontic treatment mechanics because of its potential for increasing arch perimeter to alleviate crowding in the maxillary arch without adversely affecting facial profile. Hence, the present investigation was conducted to establish a correlation between transverse expansion and changes in the arch perimeter, arch width and arch length. Methods: For this purpose, 10 subjects (five males, five females were selected who had been treated by rapid maxillary expansion (RME using hyrax rapid palatal expander followed by fixed mechanotherapy (PEA. Pretreatment (T1, postexpansion (T2, and posttreatment (T3 dental models were compared for dental changes brought about by RME treatment and its stability at the end of fixed mechanotherapy. After model measurements were made, the changes between T1-T2, T2-T3 and T1-T3 were determined for each patient. The mean difference between T1-T2, T2-T3 and T1-T3 were compared to assess the effects of RME on dental arch measurements. Results are expressed as mean ± standard deviation and are compared by repeated measures analysis of variance followed by a post-hoc test. Arch perimeter changes are correlated with changes in arch widths at the canine, premolar and molar

  5. An Interactive Tool for Automatic Predimensioning and Numerical Modeling of Arch Dams

    Directory of Open Access Journals (Sweden)

    D. J. Vicente

    2017-01-01

    Full Text Available The construction of double-curvature arch dams is an attractive solution from an economic viewpoint due to the reduced volume of concrete necessary for their construction as compared to conventional gravity dams. Due to their complex geometry, many criteria have arisen for their design. However, the most widespread methods are based on recommendations of traditional technical documents without taking into account the possibilities of computer-aided design. In this paper, an innovative software tool to design FEM models of double-curvature arch dams is presented. Several capabilities are allowed: simplified geometry creation (interesting for academic purposes, preliminary geometrical design, high-detailed model construction, and stochastic calculation performance (introducing uncertainty associated with material properties and other parameters. This paper specially focuses on geometrical issues describing the functionalities of the tool and the fundamentals of the design procedure with regard to the following aspects: topography, reference cylinder, excavation depth, crown cantilever thickness and curvature, horizontal arch curvature, excavation and concrete mass volume, and additional elements such as joints or spillways. Examples of application on two Spanish dams are presented and the results obtained analyzed.

  6. ArchE - An Architecture Design Assistant

    Science.gov (United States)

    2007-08-02

    Architecture Design Assistant Len Bass August 2, 2007 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the...ArchE - An Architecture Design Assistant 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK...X, Module X 3 Author / Presenter, Date if Needed What is ArchE? ArchE is a software architecture design assistant, which: • Takes quality and

  7. Influence of retainer design on two-unit cantilever resin-bonded glass fiber reinforced composite fixed dental prostheses: an in vitro and finite element analysis study.

    Science.gov (United States)

    Keulemans, Filip; De Jager, Niek; Kleverlaan, Cornelis J; Feilzer, Albert J

    2008-10-01

    The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass fiber-reinforced composite (FRC) fixed dental prostheses (FDP). Four retainer designs were tested: a proximal box, a step-box, a dual wing, and a step-box-wing. Of each design on 8 human mandibular molars, FRC-FDPs of a premolar size were produced. The FRC framework was made of resin impregnated unidirectional glass fibers (Estenia C&B EG Fiber, Kuraray) and veneered with hybrid resin composite (Estenia C&B, Kuraray). Panavia F 2.0 (Kuraray) was used as resin luting cement. FRC-FDPs were loaded to failure in a universal testing machine. One-way ANOVA and Tukey's post-hoc test were used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FDPs (proximal box: 300 +/- 65 N; step-box: 309 +/- 37 N) compared to wing-retained FDPs (p optimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FDPs.

  8. Three-electrode self-actuating self-sensing quartz cantilever: design, analysis, and experimental verification.

    Science.gov (United States)

    Chen, C Julian; Schwarz, Alex; Wiesendanger, Roland; Horn, Oliver; Müller, Jörg

    2010-05-01

    We present a novel quartz cantilever for frequency-modulation atomic force microscopy (FM-AFM) which has three electrodes: an actuating electrode, a sensing electrode, and a ground electrode. By applying an ac signal on the actuating electrode, the cantilever is set to vibrate. If the frequency of actuation voltage closely matches one of the characteristic frequencies of the cantilever, a sharp resonance should be observed. The vibration of the cantilever in turn generates a current on the sensing electrode. The arrangement of the electrodes is such that the cross-talk capacitance between the actuating electrode and the sensing electrode is less than 10(-16) F, thus the direct coupling is negligible. To verify the principle, a number of samples were made. Direct measurements with a Nanosurf easyPPL controller and detector showed that for each cantilever, one or more vibrational modes can be excited and detected. Using classical theory of elasticity, it is shown that such novel cantilevers with proper dimensions can provide optimized performance and sensitivity in FM-AFM with very simple electronics.

  9. Cantilever sensors: Nanomechanical tools for diagnostics

    DEFF Research Database (Denmark)

    Datar, R.; Kim, S.; Jeon, S.

    2009-01-01

    Cantilever sensors have attracted considerable attention over the last decade because of their potential as a highly sensitive sensor platform for high throughput and multiplexed detection of proteins and nucleic acids. A micromachined cantilever platform integrates nanoscale science and microfab......Cantilever sensors have attracted considerable attention over the last decade because of their potential as a highly sensitive sensor platform for high throughput and multiplexed detection of proteins and nucleic acids. A micromachined cantilever platform integrates nanoscale science...... and microfabrication technology for the label-free detection of biological molecules, allowing miniaturization. Molecular adsorption, when restricted to a single side of a deformable cantilever beam, results in measurable bending of the cantilever. This nanoscale deflection is caused by a variation in the cantilever...... surface stress due to biomolecular interactions and can be measured by optical or electrical means, thereby reporting on the presence of biomolecules. Biological specificity in detection is typically achieved by immobilizing selective receptors or probe molecules on one side of the cantilever using...

  10. Avaliação da inclinação dentoalveolar e dimensões do arco superior em mordidas cruzadas posteriores tratadas com aparelho expansor removível e fixo Evaluation of the dentoalveolar inclination and upper arch dimensions in posterior cross bite treated with removable and fixed expander appliances

    Directory of Open Access Journals (Sweden)

    Ary dos Santos-Pinto

    2006-08-01

    Full Text Available OBJETIVO: avaliar as diferenças produzidas nas dimensões e forma de arco pelos tratamentos com aparelho expansor fixo tipo Hyrax e aparelho expansor removível tipo Placa de Hawley com parafuso expansor palatino centralizado. MATERIAL E MÉTODOS: foram selecionados modelos de estudo iniciais e finais de 31 crianças portadoras de mordida cruzada posterior, de ambos os gêneros, de origem étnica diversa e na fase da dentadura mista, tratadas nos cursos de Graduação e Pós-Graduação em Ortodontia do Departamento de Clínica Infantil da Faculdade de Odontologia de Araraquara - UNESP. Destas crianças, 15 foram tratadas com uso do aparelho expansor fixo tipo Hyrax e as demais 16 crianças foram tratados com expansão rápida da maxila efetuada com o aparelho expansor fixo. Foram realizadas medidas das distâncias intercaninos e intermolares, da inclinação do processo alveolar e inclinação dentária nas imagens escaneadas do arco superior e do contorno do palato, obtido com auxílio de um template ajustável e do programa de análises Radiocef Studio. RESULTADOS E CONCLUSÕES: os resultados indicam uma mudança significante nas distâncias intercaninos e intermolares em ambos os grupos e uma inclinação dentária e do processo alveolar para vestibular significante no grupo tratado com o aparelho expansor fixo. A expansão conseguida pelo aparelho expansor fixo foi aproximadamente o dobro da promovida pelo aparelho expansor removível.AIM: to evaluate the differences of arch dimension and arch form obtained by treating the posterior cross-bite with the fixed expander appliance Hyrax and with the removable expander type Hawley plate with centralized screw. METHODS: initial and final study models of thirty-one children in the mixed dentition phase, of both genders and same ethnic origin treated in the Araraquara School of Dentistry, UNESP, São Paulo, Brazil - undergraduate and graduation Orthodontic courses. Fifteen children were treated

  11. Polymeric Cantilever Arrays for Biosensing Applications

    DEFF Research Database (Denmark)

    Calleja, M.; Tamayo, J.; Johansson, Alicia

    2003-01-01

    We report the fabrication of arrays of polymeric cantilevers for biochemistry applications. The cantilevers are fabricated in the polymer SU-8. The use of a polymer as the component material for the cantilevers provides the sensors with very high sensitivity due to convenient mechanical material...... properties. The fabrication process is based on spin coating of the photosensitive polymer and near-ultraviolet exposure. The method allows obtaining well-controlled and uniform mechanical properties of the cantilevers. The elastic constant of the cantilevers was measured, and their dynamic response...

  12. Cantilevered probe detector with piezoelectric element

    Science.gov (United States)

    Adams, Jesse D; Sulchek, Todd A; Feigin, Stuart C

    2013-04-30

    A disclosed chemical detection system for detecting a target material, such as an explosive material, can include a cantilevered probe, a probe heater coupled to the cantilevered probe, and a piezoelectric element disposed on the cantilevered probe. The piezoelectric element can be configured as a detector and/or an actuator. Detection can include, for example, detecting a movement of the cantilevered probe or a property of the cantilevered probe. The movement or a change in the property of the cantilevered probe can occur, for example, by adsorption of the target material, desorption of the target material, reaction of the target material and/or phase change of the target material. Examples of detectable movements and properties include temperature shifts, impedance shifts, and resonant frequency shifts of the cantilevered probe. The overall chemical detection system can be incorporated, for example, into a handheld explosive material detection system.

  13. Comparative study on the mechanical mechanism of confined concrete supporting arches in underground engineering.

    Science.gov (United States)

    Lv, Zhijin; Qin, Qian; Jiang, Bei; Luan, Yingcheng; Yu, Hengchang

    2018-01-01

    In order to solve the supporting problem in underground engineering with high stress, square steel confined concrete (SQCC) supporting method is adopted to enhance the control on surrounding rocks, and the control effect is remarkable. The commonly used cross section shapes of confined concrete arch are square and circular. At present, designers have no consensus on which kind is more proper. To search for the answer, this paper makes an analysis on the mechanical properties of the two shapes of the cross-sections. A full-scale indoor comparative test was carried out on the commonly used straight-wall semi-circular SQCC arch and circular steel confined concrete arch (CCC arch). This test is based on self-developed full-scale test system for confined concrete arch. Our research, combining with the numerical analysis, shows: (1) SQCC arch is consistent with CCC arch in the deformation and failure mode. The largest damages parts are at the legs of both of them. (2) The SQCC arch's bearing capability is 1286.9 kN, and the CCC arch's ultimate bearing capability is 1072.4kN. Thus, the SQCC arch's bearing capability is 1.2 times that of the CCC arch. (3) The arches are subjected to combined compression and bending, bending moment is the main reason for the arch failure. The section moment of inertia of SQCC arch is 1.26 times of that of CCC arch, and the former is better than the latter in bending performance. The ultimate bearing capacity is positively correlated with the size of the moment of inertia. Based on the above research, the engineering suggestions are as follows: (1) To improve the bearing capacity of the arch, the cross-sectional shape of the chamber should be optimized and the arch bearing mode changed accordingly. (2) The key damaged positions, such as the arch leg, should be reinforced, optimizing the state of force on the arch. SQCC arches should be used for supporting in underground engineering, which is under stronger influence of the bending moment and

  14. A closed-loop system for frequency tracking of piezoresistive cantilever sensors

    Science.gov (United States)

    Wasisto, Hutomo Suryo; Zhang, Qing; Merzsch, Stephan; Waag, Andreas; Peiner, Erwin

    2013-05-01

    A closed loop circuit capable of tracking resonant frequencies for MEMS-based piezoresistive cantilever resonators is developed in this work. The proposed closed-loop system is mainly based on a phase locked loop (PLL) circuit. In order to lock onto the resonant frequency of the resonator, an actuation signal generated from a voltage-controlled oscillator (VCO) is locked to the phase of the input reference signal of the cantilever sensor. In addition to the PLL component, an instrumentation amplifier and an active low pass filter (LPF) are connected to the system for gaining the amplitude and reducing the noise of the cantilever output signals. The LPF can transform a rectangular signal into a sinusoidal signal with voltage amplitudes ranging from 5 to 10 V which are sufficient for a piezoactuator input (i.e., maintaining a large output signal of the cantilever sensor). To demonstrate the functionality of the system, a self-sensing silicon cantilever resonator with a built-in piezoresistive Wheatstone bridge is fabricated and integrated with the circuit. A piezoactuator is utilized for actuating the cantilever into resonance. Implementation of this closed loop system is used to track the resonant frequency of a silicon cantilever-based sensor resonating at 9.4 kHz under a cross-sensitivity test of ambient temperature. The changes of the resonant frequency are interpreted using a frequency counter connected to the system. From the experimental results, the temperature sensitivity and coefficient of the employed sensor are 0.3 Hz/°C and 32.8 ppm/°C, respectively. The frequency stability of the system can reach up to 0.08 Hz. The development of this system will enable real-time nanoparticle monitoring systems and provide a miniaturization of the instrumentation modules for cantilever-based nanoparticle detectors.

  15. Investigation of polymer derived ceramics cantilevers for application of high speed atomic force microscopy

    Science.gov (United States)

    Wu, Chia-Yun

    High speed Atomic Force Microscopy (AFM) has a wide variety of applications ranging from nanomanufacturing to biophysics. In order to have higher scanning speed of certain AFM modes, high resonant frequency cantilevers are needed; therefore, the goal of this research is to investigate using polymer derived ceramics for possible applications in making high resonant frequency AFM cantilevers using complex cross sections. The polymer derived ceramic that will be studied, is silicon carbide. Polymer derived ceramics offer a potentially more economic fabrication approach for MEMS due to their relatively low processing temperatures and ease of complex shape design. Photolithography was used to make the desired cantilever shapes with micron scale size followed by a wet etching process to release the cantilevers from the substrates. The whole manufacturing process we use borrow well-developed techniques from the semiconducting industry, and as such this project also could offer the opportunity to reduce the fabrication cost of AFM cantilevers and MEMS in general. The characteristics of silicon carbide made from the precursor polymer, SMP-10 (Starfire Systems), were studied. In order to produce high qualities of silicon carbide cantilevers, where the major concern is defects, proper process parameters needed to be determined. Films of polymer derived ceramics often have defects due to shrinkage during the conversion process. Thus control of defects was a central issue in this study. A second, related concern was preventing oxidation; the polymer derived ceramics we chose is easily oxidized during processing. Establishing an environment without oxygen in the whole process was a significant challenge in the project. The optimization of the parameters for using photolithography and wet etching process was the final and central goal of the project; well established techniques used in microfabrication were modified for use in making the cantilever in the project. The techniques

  16. Multifrequency Piezoelectric Energy Harvester Based on Polygon-Shaped Cantilever Array

    Directory of Open Access Journals (Sweden)

    Dalius Mažeika

    2018-01-01

    Full Text Available This paper focuses on numerical and experimental investigations of a novel design piezoelectric energy harvester. Investigated harvester is based on polygon-shaped cantilever array and employs multifrequency operating principle. It consists of eight cantilevers with irregular design of cross-sectional area. Cantilevers are connected to each other by specific angle to form polygon-shaped structure. Moreover, seven seismic masses with additional lever arms are added in order to create additional rotation moment. Numerical investigation showed that piezoelectric polygon-shaped energy harvester has five natural frequencies in the frequency range from 10 Hz to 240 Hz, where the first and the second bending modes of the cantilevers are dominating. Maximum output voltage density and energy density equal to 50.03 mV/mm3 and 604 μJ/mm3, respectively, were obtained during numerical simulation. Prototype of piezoelectric harvester was made and experimental investigation was performed. Experimental measurements of the electrical characteristics showed that maximum output voltage density, energy density, and output power are 37.5 mV/mm3, 815.16 μJ/mm3, and 65.24 μW, respectively.

  17. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    Science.gov (United States)

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  18. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses.

    Science.gov (United States)

    Yilmaz, Burak; Alp, Gülce; Seidt, Jeremy; Johnston, William M; Vitter, Roger; McGlumphy, Edwin A

    2018-01-06

    The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). Statistically significant differences were found among load-to-fracture values of different HDPs (PCAD-CAM polymer. GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers

  19. Fabrication of thin SU-8 cantilevers: initial bending, release and time stability

    International Nuclear Information System (INIS)

    Keller, Stephan; Boisen, Anja; Haefliger, Daniel

    2010-01-01

    SU-8 cantilevers with a thickness of 2 µm were fabricated using a dry release method and two steps of SU-8 photolithography. The processing of the thin SU-8 film defining the cantilevers was experimentally optimized to achieve low initial bending due to residual stress gradients. In parallel, the rotational deformation at the clamping point allowed a qualitative assessment of the device release from the fluorocarbon-coated substrate. The change of these parameters during several months of storage at ambient temperature was investigated in detail. The introduction of a long hard bake in an oven after development of the thin SU-8 film resulted in reduced cantilever bending due to removal of residual stress gradients. Further, improved time-stability of the devices was achieved due to the enhanced cross-linking of the polymer. A post-exposure bake at a temperature T PEB = 50 °C followed by a hard bake at T HB = 90 °C proved to be optimal to ensure low cantilever bending and low rotational deformation due to excellent device release and low change of these properties with time. With the optimized process, the reproducible fabrication of arrays with 2 µm thick cantilevers with a length of 500 µm and an initial bending of less than 20 µm was possible. The theoretical spring constant of these cantilevers is k = 4.8 ± 2.5 mN m −1 , which is comparable to the value for Si cantilevers with identical dimensions and a thickness of 500 nm.

  20. Characterizing Vibrating Cantilevers for Liquid Viscosity and Density Sensing

    Directory of Open Access Journals (Sweden)

    Bernhard Jakoby

    2008-10-01

    Full Text Available Miniaturized liquid sensors are essential devices in online process or condition monitoring. In case of viscosity and density sensing, microacoustic sensors such as quartz crystal resonators or SAW devices have proved particularly useful. However, these devices basically measure a thin-film viscosity, which is often not comparable to the macroscopic parameters probed by conventional viscometers. Miniaturized cantilever-based devices are interesting alternatives for such applications, but here the interaction between the liquid and the oscillating beam is more involved. In our contribution, we describe a measurement setup, which allows the investigation of this interaction for different beam cross-sections. We present an analytical model based on an approximation of the immersed cantilever as an oscillating sphere comprising the effective mass and the intrinsic damping of the cantilever and additional mass and damping due to the liquid loading. The model parameters are obtained from measurements with well-known sample liquids by a curve fitting procedure. Finally, we present the measurement of viscosity and density of an unknown sample liquid, demonstrating the feasibility of the model.

  1. Graphene cantilever under Casimir force

    Science.gov (United States)

    Derras-Chouk, Amel; Chudnovsky, Eugene M.; Garanin, Dmitry A.; Jaafar, Reem

    2018-05-01

    The stability of graphene cantilever under Casimir attraction to an underlying conductor is investigated. The dependence of the instability threshold on temperature and flexural rigidity is obtained. Analytical work is supplemented by numerical computation of the critical temperature above which the graphene cantilever irreversibly bends down and attaches to the conductor. The geometry of the attachment and exfoliation of the graphene sheet is discussed. It is argued that graphene cantilever can be an excellent tool for precision measurements of the Casimir force.

  2. Three-way flexible cantilever probes for static contact

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Jensen, Helle Vendelbo

    2011-01-01

    In micro four-point probe measurements, three-way flexible L-shaped cantilever probes show significant advantages over conventional straight cantilever probes. The L-shaped cantilever allows static contact to the sample surface which reduces the frictional wear of the cantilever tips. We analyze...

  3. Oscillations of end loaded cantilever beams

    International Nuclear Information System (INIS)

    Macho-Stadler, E; Elejalde-García, M J; Llanos-Vázquez, R

    2015-01-01

    This article presents several simple experiments based on changing transverse vibration frequencies in a cantilever beam, when acted on by an external attached mass load at the free end. By using a mechanical wave driver, available in introductory undergraduate laboratories, we provide various experimental results for end loaded cantilever beams that fit reasonably well into a linear equation. The behaviour of the cantilever beam’s weak-damping resonance response is studied for the case of metal resonance strips. As the mass load increases, a more pronounced decrease occurs in the fundamental frequency of beam vibration. It is important to note that cantilever construction is often used in architectural design and engineering construction projects but current analysis also predicts the influence of mass load on the sound generated by musical free reeds with boundary conditions similar to a cantilever beam. (paper)

  4. Oscillations of end loaded cantilever beams

    Science.gov (United States)

    Macho-Stadler, E.; Elejalde-García, M. J.; Llanos-Vázquez, R.

    2015-09-01

    This article presents several simple experiments based on changing transverse vibration frequencies in a cantilever beam, when acted on by an external attached mass load at the free end. By using a mechanical wave driver, available in introductory undergraduate laboratories, we provide various experimental results for end loaded cantilever beams that fit reasonably well into a linear equation. The behaviour of the cantilever beam’s weak-damping resonance response is studied for the case of metal resonance strips. As the mass load increases, a more pronounced decrease occurs in the fundamental frequency of beam vibration. It is important to note that cantilever construction is often used in architectural design and engineering construction projects but current analysis also predicts the influence of mass load on the sound generated by musical free reeds with boundary conditions similar to a cantilever beam.

  5. Cantilever-like micromechanical sensors

    DEFF Research Database (Denmark)

    Boisen, Anja; Dohn, Søren; Keller, Stephan Sylvest

    2011-01-01

    The field of cantilever-based sensing emerged in the mid-1990s and is today a well-known technology for label-free sensing which holds promise as a technique for cheap, portable, sensitive and highly parallel analysis systems. The research in sensor realization as well as sensor applications has...... increased significantly over the past 10 years. In this review we will present the basic modes of operation in cantilever-like micromechanical sensors and discuss optical and electrical means for signal transduction. The fundamental processes for realizing miniaturized cantilevers are described with focus...... on silicon-and polymer-based technologies. Examples of recent sensor applications are given covering such diverse fields as drug discovery, food diagnostics, material characterizations and explosives detection....

  6. Understanding interferometry for micro-cantilever displacement detection

    Directory of Open Access Journals (Sweden)

    Alexander von Schmidsfeld

    2016-06-01

    Full Text Available Interferometric displacement detection in a cantilever-based non-contact atomic force microscope (NC-AFM operated in ultra-high vacuum is demonstrated for the Michelson and Fabry–Pérot modes of operation. Each mode is addressed by appropriately adjusting the distance between the fiber end delivering and collecting light and a highly reflective micro-cantilever, both together forming the interferometric cavity. For a precise measurement of the cantilever displacement, the relative positioning of fiber and cantilever is of critical importance. We describe a systematic approach for accurate alignment as well as the implications of deficient fiber–cantilever configurations. In the Fabry–Pérot regime, the displacement noise spectral density strongly decreases with decreasing distance between the fiber-end and the cantilever, yielding a noise floor of 24 fm/Hz0.5 under optimum conditions.

  7. Three-way flexible cantilever probes for static contact

    International Nuclear Information System (INIS)

    Wang, Fei; Petersen, Dirch H; Hansen, Christian; Mortensen, Dennis; Friis, Lars; Hansen, Ole; Jensen, Helle V

    2011-01-01

    In micro four-point probe measurements, three-way flexible L-shaped cantilever probes show significant advantages over conventional straight cantilever probes. The L-shaped cantilever allows static contact to the sample surface which reduces the frictional wear of the cantilever tips. We analyze the geometrical design space that must be fulfilled for the cantilevers to obtain static contact with the test sample. The design space relates the spring constant tensor of the cantilevers to the minimal value of the static tip-to-sample friction coefficient. Using an approximate model, we provide the analytical calculation of the compliance matrix of the L-shaped cantilever. Compared to results derived from finite element model simulations, the theoretical model provides a good qualitative analysis while deviations for the absolute values are seen. From a statistical analysis, the deviation is small for cantilevers with low effective spring constants, while the deviation is significant for large spring constants where the quasi one-dimensional approximation is no longer valid

  8. Arch reconstruction with autologous pulmonary artery patch in interrupted aortic arch.

    Science.gov (United States)

    Lee, Won-Young; Park, Jeong-Jun

    2014-04-01

    Various surgical techniques have been developed for the repair of an interrupted aortic arch. However, tension and Gothic arch formation at the anastomotic site have remained major problems for these techniques: Excessive tension causes arch stenosis and left main bronchus compression, and Gothic arch configuration is related to cardiovascular complications. To resolve these problems, we adopted a modified surgical technique of distal aortic arch augmentation using an autologous main pulmonary artery patch. The descending aorta was then anastomosed to the augmented aortic arch in an end-to-side manner. Here, we report two cases of interrupted aortic arch that were repaired using this technique.

  9. Segmentation of a Vibro-Shock Cantilever-Type Piezoelectric Energy Harvester Operating in Higher Transverse Vibration Modes

    Directory of Open Access Journals (Sweden)

    Darius Zizys

    2015-12-01

    Full Text Available The piezoelectric transduction mechanism is a common vibration-to-electric energy harvesting approach. Piezoelectric energy harvesters are typically mounted on a vibrating host structure, whereby alternating voltage output is generated by a dynamic strain field. A design target in this case is to match the natural frequency of the harvester to the ambient excitation frequency for the device to operate in resonance mode, thus significantly increasing vibration amplitudes and, as a result, energy output. Other fundamental vibration modes have strain nodes, where the dynamic strain field changes sign in the direction of the cantilever length. The paper reports on a dimensionless numerical transient analysis of a cantilever of a constant cross-section and an optimally-shaped cantilever with the objective to accurately predict the position of a strain node. Total effective strain produced by both cantilevers segmented at the strain node is calculated via transient analysis and compared to the strain output produced by the cantilevers segmented at strain nodes obtained from modal analysis, demonstrating a 7% increase in energy output. Theoretical results were experimentally verified by using open-circuit voltage values measured for the cantilevers segmented at optimal and suboptimal segmentation lines.

  10. Fabrication of thin SU-8 cantilevers: initial bending, release and time stability

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Haefliger, D.; Boisen, Anja

    2010-01-01

    SU-8 cantilevers with a thickness of 2 mu m were fabricated using a dry release method and two steps of SU-8 photolithography. The processing of the thin SU-8 film defining the cantilevers was experimentally optimized to achieve low initial bending due to residual stress gradients. In parallel......, the rotational deformation at the clamping point allowed a qualitative assessment of the device release from the fluorocarbon-coated substrate. The change of these parameters during several months of storage at ambient temperature was investigated in detail. The introduction of a long hard bake in an oven after...... development of the thin SU-8 film resulted in reduced cantilever bending due to removal of residual stress gradients. Further, improved time-stability of the devices was achieved due to the enhanced cross-linking of the polymer. A post-exposure bake at a temperature T-PEB = 50 degrees C followed by a hard...

  11. Development of a microfabricated electrochemical-cantilever hybrid platform

    DEFF Research Database (Denmark)

    Fischer, Lee MacKenzie; Pedersen, Christoffer; Elkjær, Karl

    2011-01-01

    The design and fabrication of a combined electrochemical-cantilever microfluidic system is described. A chip integrating cantilevers with electrodes into a microchannel is presented with the accompanying polymer flow cell. Issues such as electrical and fluid connections are addressed......, electromechanical behavior in ionic solution is investigated, and two uses of the system are demonstrated. First, all cantilevers are functionalized with cysteine, to facilitate detection of Cu2+ ions, then one cantilever is electrochemically cleaned in situ to generate a reference cantilever for differential...

  12. Polymeric cantilever-based biosensors with integrated readout

    DEFF Research Database (Denmark)

    Johansson, Alicia; Blagoi, Gabriela; Boisen, Anja

    2006-01-01

    The authors present an SU-8 cantilever chip with integrated piezoresistors for detection of surface stress changes due to adsorption of biomolecules on the cantilever surface. Mercaptohexanol is used as a model biomolecule to study molecular interactions with Au-coated SU-8 cantilevers and surfac...

  13. Microstructuring of piezoresistive cantilevers for gas detection and analysis

    International Nuclear Information System (INIS)

    Sarov, Y.; Sarova, V.; Bitterlich, Ch.; Richter, O.; Guliyev, E.; Zoellner, J.-P.; Rangelow, I. W.; Andok, R.; Bencurova, A.

    2011-01-01

    In this work we report on a design and fabrication of cantilevers for gas detection and analysis. The cantilevers have expanded area of interaction with the gas, while the signal transduction is realized by an integrated piezoresistive deflection sensor, placed at the narrowed cantilever base with highest stress along the cantilever. Moreover, the cantilevers have integrated bimorph micro-actuator detection in a static and dynamic mode. The cantilevers are feasible as pressure, temperature and flow sensors and under chemical functionalization - for gas recognition, tracing and composition analysis. (authors)

  14. Scanning conductance microscopy investigations on fixed human chromosomes

    DEFF Research Database (Denmark)

    Clausen, Casper Hyttel; Lange, Jacob Moresco; Jensen, Linda Boye

    2008-01-01

    Scanning conductance microscopy investigations were carried out in air on human chromosomes fixed on pre-fabricated SiO2 surfaces with a backgate. The point of the investigation was to estimate the dielectric constant of fixed human chromosomes in order to use it for microfluidic device...... optimization. The phase shift caused by the electrostatic forces, together with geometrical measurements of the atomic force microscopy (AFM) cantilever and the chromosomes were used to estimate a value,for the dielectric constant of different human chromosomes....

  15. Association between breastfeeding duration, non-nutritive sucking habits and dental arch dimensions in deciduous dentition: a cross-sectional study

    OpenAIRE

    Agarwal, Shiv Shankar; Nehra, Karan; Sharma, Mohit; Jayan, Balakrishna; Poonia, Anish; Bhattal, Hiteshwar

    2014-01-01

    Background This cross-sectional retrospective study was conducted to determine association between breastfeeding duration, non-nutritive sucking habits, dental arch transverse diameters, posterior crossbite and anterior open bite in deciduous dentition. Methods 415 children (228 males and 187 females), 4 to 6 years old, from a mixed Indian population were clinically examined. Based on written questionnaire answered by parents, children were divided into two groups: group 1 (breastfed for

  16. Vibration energy harvesting using piezoelectric unimorph cantilevers with unequal piezoelectric and nonpiezoelectric lengths

    OpenAIRE

    Gao, Xiaotong; Shih, Wei-Heng; Shih, Wan Y.

    2010-01-01

    We have examined a piezoelectric unimorph cantilever (PUC) with unequal piezoelectric and nonpiezoelectric lengths for vibration energy harvesting theoretically by extending the analysis of a PUC with equal piezoelectric and nonpiezoelectric lengths. The theoretical approach was validated by experiments. A case study showed that for a fixed vibration frequency, the maximum open-circuit induced voltage which was important for charge storage for later use occurred with a PUC that had a nonpiezo...

  17. Cantilever-Based Microwave Biosensors: Analysis, Designs and Optimizations

    DEFF Research Database (Denmark)

    Jiang, Chenhui; Johansen, Tom Keinicke; Jónasson, Sævar Þór

    2011-01-01

    This paper presents a novel microwave readout scheme for measuring deflection of cantilevers in nanometer range. The cantilever deflection can be sensed by the variation of transmission levels or resonant frequencies of microwave signals. The sensitivity of the cantilever biosensor based on LC...

  18. Recurrent Pneumonia due to Double Aortic Arch

    Directory of Open Access Journals (Sweden)

    I. Sedighi

    2012-04-01

    Full Text Available Introduction: Pneumonia is one of the most common infections during childhood. In children with recurrent bacterial pneumonia complete evaluation for underlying factors is necessary. The most common underlying diseases include: antibody deficiencies , cystic fibrosis , tracheoesophageal fistula and increased pulmonary blood flow. Vascular ring and its pressure effect is a less common cause of stridor and recurrent pneumonia. Congenital abnormalities in aortic arch and main branches which form vascular ring around esophagus and trachea with variable pressure effect cause respiratory symptoms such as stridor , wheezing and recurrent pneumoniaCase Report: A 2 year old boy was admitted in our hospital with respiratory distress and cough . Chest x-Ray demonstrated right lobar pneumonia. He had history of stridor and wheezing from neonatal period and hospitalization due to pneumonia for four times. The patient received appropriate antibiotics. Despite fever and respiratory distress improvement, wheezing continued. Review of his medical documents showed fixed pressure effect on posterior aspect of esophagus in barium swallow. In CT angiography we confirmed double aortic arch.Conclusion: Double aortic arch is one of the causes of persistant respiratory symptom and recurrent pneumonia in children for which fluoroscopic barium swallow is the first non-invasive diagnostic method.(Sci J Hamadan Univ Med Sci 2012;19(1:70-74

  19. Lorentz force actuation of a heated atomic force microscope cantilever.

    Science.gov (United States)

    Lee, Byeonghee; Prater, Craig B; King, William P

    2012-02-10

    We report Lorentz force-induced actuation of a silicon microcantilever having an integrated resistive heater. Oscillating current through the cantilever interacts with the magnetic field around a NdFeB permanent magnet and induces a Lorentz force that deflects the cantilever. The same current induces cantilever heating. With AC currents as low as 0.2 mA, the cantilever can be oscillated as much as 80 nm at resonance with a DC temperature rise of less than 5 °C. By comparison, the AC temperature variation leads to a thermomechanical oscillation that is about 1000 times smaller than the Lorentz deflection at the cantilever resonance. The cantilever position in the nonuniform magnetic field affects the Lorentz force-induced deflection, with the magnetic field parallel to the cantilever having the largest effect on cantilever actuation. We demonstrate how the cantilever actuation can be used for imaging, and for measuring the local material softening temperature by sensing the contact resonance shift.

  20. An electrochemical-cantilever platform for hybrid sensing applications

    DEFF Research Database (Denmark)

    Fischer, Lee MacKenzie; Dohn, Søren; Boisen, Anja

    2011-01-01

    This work presents a fully-functional, microfabricated electrochemical-cantilever hybrid platform with flow control. A new cantilever chip format is designed, fabricated, and mounted in a custom polymer flow cell. Issues such as leakage and optical/electrical access are addressed, and combined...... mechanical and electrochemical performance is investigated. Lastly, a cantilever is “defunctionalized” in situ to create a reference cantilever for differential measurements in detection of Cu2+ ions at concentrations of 10 μM and 100 nM....

  1. A capacitive power sensor based on the MEMS cantilever beam fabricated by GaAs MMIC technology

    International Nuclear Information System (INIS)

    Yi, Zhenxiang; Liao, Xiaoping

    2013-01-01

    In this paper, a novel capacitive power sensor based on the microelectromechanical systems (MEMS) cantilever beam at 8–12 GHz is proposed, fabricated and tested. The presented design can not only realize a cantilever beam instead of the conventional fixed–fixed beam, but also provide fine compatibility with the GaAs monolithic microwave integrated circuit (MMIC) process. When the displacement of the cantilever beam is very small compared with the initial height of the air gap, the capacitance change between the measuring electrode and the cantilever beam has an approximately linear dependence on the incident radio frequency (RF) power. Impedance compensating technology, by modifying the slot width of the coplanar waveguide transmission line, is adopted to minimize the effect of the cantilever beam on the power sensor; its validity is verified by the simulation of high frequency structure simulator software. The power sensor has been fabricated successfully by Au surface micromachining using polyimide as the sacrificial layer on the GaAs substrate. Optimization of the design with impedance compensating technology has resulted in a measured return loss of less than −25 dB and an insertion loss of around 0.1 dB at 8–12 GHz, which shows the slight effect of the cantilever beam on the microwave performance of this power sensor. The measured capacitance change starts from 0.7 fF to 1.3 fF when the incident RF power increases from 100 to 200 mW and an approximate linear dependence has been obtained. The measured sensitivities of the sensor are about 6.16, 6.27 and 6.03 aF mW −1 at 8, 10 and 12 GHz, respectively. (paper)

  2. Cantilever arrays with self-aligned nanotips of uniform height

    International Nuclear Information System (INIS)

    Koelmans, W W; Peters, T; Berenschot, E; De Boer, M J; Siekman, M H; Abelmann, L

    2012-01-01

    Cantilever arrays are employed to increase the throughput of imaging and manipulation at the nanoscale. We present a fabrication process to construct cantilever arrays with nanotips that show a uniform tip–sample distance. Such uniformity is crucial, because in many applications the cantilevers do not feature individual tip–sample spacing control. Uniform cantilever arrays lead to very similar tip–sample interaction within an array, enable non-contact modes for arrays and give better control over the load force in contact modes. The developed process flow uses a single mask to define both tips and cantilevers. An additional mask is required for the back side etch. The tips are self-aligned in the convex corner at the free end of each cantilever. Although we use standard optical contact lithography, we show that the convex corner can be sharpened to a nanometre scale radius by an isotropic underetch step. The process is robust and wafer-scale. The resonance frequencies of the cantilevers within an array are shown to be highly uniform with a relative standard error of 0.26% or lower. The tip–sample distance within an array of up to ten cantilevers is measured to have a standard error around 10 nm. An imaging demonstration using the AFM shows that all cantilevers in the array have a sharp tip with a radius below 10 nm. The process flow for the cantilever arrays finds application in probe-based nanolithography, probe-based data storage, nanomanufacturing and parallel scanning probe microscopy. (paper)

  3. Calibration of higher eigenmodes of cantilevers

    International Nuclear Information System (INIS)

    Labuda, Aleksander; Kocun, Marta; Walsh, Tim; Meinhold, Jieh; Proksch, Tania; Meinhold, Waiman; Anderson, Caleb; Proksch, Roger; Lysy, Martin

    2016-01-01

    A method is presented for calibrating the higher eigenmodes (resonant modes) of atomic force microscopy cantilevers that can be performed prior to any tip-sample interaction. The method leverages recent efforts in accurately calibrating the first eigenmode by providing the higher-mode stiffness as a ratio to the first mode stiffness. A one-time calibration routine must be performed for every cantilever type to determine a power-law relationship between stiffness and frequency, which is then stored for future use on similar cantilevers. Then, future calibrations only require a measurement of the ratio of resonant frequencies and the stiffness of the first mode. This method is verified through stiffness measurements using three independent approaches: interferometric measurement, AC approach-curve calibration, and finite element analysis simulation. Power-law values for calibrating higher-mode stiffnesses are reported for several cantilever models. Once the higher-mode stiffnesses are known, the amplitude of each mode can also be calibrated from the thermal spectrum by application of the equipartition theorem.

  4. Calibration of higher eigenmodes of cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Labuda, Aleksander; Kocun, Marta; Walsh, Tim; Meinhold, Jieh; Proksch, Tania; Meinhold, Waiman; Anderson, Caleb; Proksch, Roger [Asylum Research, an Oxford Instruments Company, Santa Barbara, California 93117 (United States); Lysy, Martin [Department of Statistics and Actuarial Science, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada)

    2016-07-15

    A method is presented for calibrating the higher eigenmodes (resonant modes) of atomic force microscopy cantilevers that can be performed prior to any tip-sample interaction. The method leverages recent efforts in accurately calibrating the first eigenmode by providing the higher-mode stiffness as a ratio to the first mode stiffness. A one-time calibration routine must be performed for every cantilever type to determine a power-law relationship between stiffness and frequency, which is then stored for future use on similar cantilevers. Then, future calibrations only require a measurement of the ratio of resonant frequencies and the stiffness of the first mode. This method is verified through stiffness measurements using three independent approaches: interferometric measurement, AC approach-curve calibration, and finite element analysis simulation. Power-law values for calibrating higher-mode stiffnesses are reported for several cantilever models. Once the higher-mode stiffnesses are known, the amplitude of each mode can also be calibrated from the thermal spectrum by application of the equipartition theorem.

  5. A more comprehensive modeling of atomic force microscope cantilever

    International Nuclear Information System (INIS)

    Mahdavi, M.H.; Farshidianfar, A.; Tahani, M.; Mahdavi, S.; Dalir, H.

    2008-01-01

    This paper focuses on the development of a complete model of an atomic force microscope (AFM) micro-cantilever beam, based on considering the effects of four major factors in modeling the cantilever. They are: rotary inertia and shear deformation of the beam and mass and rotary inertia of the tip. A method based on distributed-parameter modeling approach is proposed to solve the governing equations. The comparisons generally show a very good agreement between the present results and the results of other investigators. As expected, rotary inertia and shear deformation of the beam decrease resonance frequency especially at high ratio of cantilever thickness to its length, and it is relatively more pronounced for higher-order frequencies, than lower ones. Mass and rotary inertia of the tip have similar effects when the mass-ratio of the tip to the cantilever is high. Moreover, the influence of each of these four factors, thickness of the cantilever, density of the tip and inclination of the cantilever on the resonance frequencies has been investigated, separately. It is felt that this work might help the engineers in reducing AFM micro-cantilever design time, by providing insight into the effects of various parameters with the micro-cantilever.

  6. Electronically droplet energy harvesting using piezoelectric cantilevers

    KAUST Repository

    Al Ahmad, Mahmoud Al; Jabbour, Ghassan E.

    2012-01-01

    A report is presented on free falling droplet energy harvesting using piezoelectric cantilevers. The harvester incorporates a multimorph clamped-free cantilever which is composed of five layers of lead zirconate titanate piezoelectric thick films

  7. Physics-based signal processing algorithms for micromachined cantilever arrays

    Science.gov (United States)

    Candy, James V; Clague, David S; Lee, Christopher L; Rudd, Robert E; Burnham, Alan K; Tringe, Joseph W

    2013-11-19

    A method of using physics-based signal processing algorithms for micromachined cantilever arrays. The methods utilize deflection of a micromachined cantilever that represents the chemical, biological, or physical element being detected. One embodiment of the method comprises the steps of modeling the deflection of the micromachined cantilever producing a deflection model, sensing the deflection of the micromachined cantilever and producing a signal representing the deflection, and comparing the signal representing the deflection with the deflection model.

  8. Establishing the maxillary occlusal plane as a requisite for placement of an immediate implant-supported fixed prosthesis in the mandible: a case report

    Directory of Open Access Journals (Sweden)

    Milton Edson Miranda

    Full Text Available INTRODUCTION: In patients with Bruxism, the attrition can result in excessive occlusal wear that exceeds the compensatory mechanism and loss of occlusion vertical dimension occurs. OBJECTIVE: The purpose of this article is to show the importance of re-establishing an adequate occlusal plane for the non treated arch by means of a fixed acrylic overlay, compatible with the prosthetic treatment of the arch to be rehabilitated. An upper maxillary fixed acrylic overlay restored the patient’s occlusal plane in an appropriate vertical dimension of occlusion together with a fixed prosthesis in the mandible, supported by five dental implants. CONCLUSION: When there is severe wear due to dental attrition in one of the arches, it is important to re-establish the occlusal plane and compensation curves in conjunction with the prosthetic treatment of the arch to be rehabilitated.

  9. Evolution Characteristic Analysis of Pressure-arch of a Double-arch Tunnel in Water-rich Strata

    Directory of Open Access Journals (Sweden)

    C. L. Li

    2016-03-01

    Full Text Available It is of importance to analyze the morphological characterization, the evolution process and the skewed effect of pressure-arch of a double-arch tunnel in the water-rich strata. Taking a buried depth 80 m double-arch tunnel as an example, a computational model of the double-arch tunnel was built by using FLAC3D technique. Then considering some aspects including groundwater conditions, tunnel depth, construction sequences and permeability coefficients, the coupling effect of stress field and seepage field in the pressure-arch of the double-arch tunnel was analyzed. The results show that the thickness of the pressure-arch induced by step-by-step excavation and display a step-descent skewed distribution from the left to the right of the double-arch tunnel. The permeability coefficient has a significant influence on the shape and the skewed effect of the pressure arch. The excavation of the bench method has a better arching condition than that of the expanding method. The abtained results provide a basic reference for the rock reinforcement design and safety construction of double-arch tunnels in the water-rich strata.

  10. Dental arch dimensions, form and tooth size ratio among a Saudi sample

    Directory of Open Access Journals (Sweden)

    Haidi Omar

    2018-01-01

    Full Text Available Objectives: To determine the dental arch dimensions and arch forms in a sample of Saudi orthodontic patients, to investigate the prevalence of Bolton anterior and overall tooth size discrepancies, and to compare the effect of gender on the measured parameters. Methods: This study is a biometric analysis of dental casts of 149 young adults recruited from different orthodontic centers in Jeddah, Saudi Arabia. The dental arch dimensions were measured. The measured parameters were arch length, arch width, Bolton’s ratio, and arch form. The data were analyzed using IBM SPSS software version 22.0 (IBM Corporation, New York, USA; this cross-sectional study was conducted between April 2015 and May 2016. Results: Dental arch measurements, including inter-canine and inter-molar distance, were found to be significantly greater in males than females (p less than 0.05. The most prevalent dental arch forms were narrow tapered (50.3% and narrow ovoid (34.2%, respectively. The prevalence of tooth size discrepancy in all cases was 43.6% for anterior ratio and 24.8% for overall ratio. The mean Bolton’s anterior ratio in all malocclusion classes was 79.81%, whereas the mean Bolton’s overall ratio was 92.21%. There was no significant difference between males and females regarding Bolton’s ratio. Conclusion: The most prevalent arch form was narrow tapered, followed by narrow ovoid. Males generally had larger dental arch measurements than females, and the prevalence of tooth size discrepancy was more in Bolton’s anterior teeth ratio than in overall ratio.

  11. Realization of cantilever arrays for parallel proximity imaging

    International Nuclear Information System (INIS)

    Sarov, Y; Ivanov, Tz; Frank, A; Zoellner, J-P; Nikolov, N; Rangelow, I W

    2010-01-01

    This paper reports on the fabrication and characterisation of self-actuating, and self-sensing cantilever arrays for large-scale parallel surface scanning. Each cantilever is integrated with a sharp silicon tip, a thermal-driven bimorph actuator, and a piezoresistive deflection sensor. Thus, the tip to the sample distance can be controlled individually for each cantilever. A radius of the tips below 10 nm is obtained, which enables nanometre in-plane surface imaging by Angstrom resolution in vertical direction. The fabricated cantilever probe arrays are also applicable for large-area manipulation, sub-10 nm metrology, bottom-up synthesis, high-speed gas analysis, for different bio-applications like recognition of DNA, RNA, or various biomarkers of a single disease, etc.

  12. Nonlinear Dynamics of Cantilever-Sample Interactions in Atomic Force Microscopy

    Science.gov (United States)

    Cantrell, John H.; Cantrell, Sean A.

    2010-01-01

    The interaction of the cantilever tip of an atomic force microscope (AFM) with the sample surface is obtained by treating the cantilever and sample as independent systems coupled by a nonlinear force acting between the cantilever tip and a volume element of the sample surface. The volume element is subjected to a restoring force from the remainder of the sample that provides dynamical equilibrium for the combined systems. The model accounts for the positions on the cantilever of the cantilever tip, laser probe, and excitation force (if any) via a basis set of set of orthogonal functions that may be generalized to account for arbitrary cantilever shapes. The basis set is extended to include nonlinear cantilever modes. The model leads to a pair of coupled nonlinear differential equations that are solved analytically using a matrix iteration procedure. The effects of oscillatory excitation forces applied either to the cantilever or to the sample surface (or to both) are obtained from the solution set and applied to the to the assessment of phase and amplitude signals generated by various acoustic-atomic force microscope (A-AFM) modalities. The influence of bistable cantilever modes of on AFM signal generation is discussed. The effects on the cantilever-sample surface dynamics of subsurface features embedded in the sample that are perturbed by surface-generated oscillatory excitation forces and carried to the cantilever via wave propagation are accounted by the Bolef-Miller propagating wave model. Expressions pertaining to signal generation and image contrast in A-AFM are obtained and applied to amplitude modulation (intermittent contact) atomic force microscopy and resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM). The influence of phase accumulation in A-AFM on image contrast is discussed, as is the effect of hard contact and maximum nonlinearity regimes of A-AFM operation.

  13. Impact of Isolation and Immobilization Layers on the Electro-Mechanical Response of Piezoresistive Nano Cantilever Sensors.

    Science.gov (United States)

    Mathew, Ribu; Sankar, A Ravi

    2018-03-01

    In the last decade, piezoresistive nano cantilever sensors have been extensively explored, especially for chemical and biological sensing applications. Piezoresistive cantilever sensors are multi-layer structures with different constituent materials. Performance of such sensors is a function of their geometry and constituent materials. For a fixed material set, the pre-requisite for optimizing the performance of a composite piezoresistive cantilever sensor is careful geometrical design of its constituent layers. Even though, treatise encompasses various designs of such sensors, typically for computational simplicity the functional layers i.e., the isolation and immobilization layers are neglected in the modeling stages. In this paper, we elucidate the impact of the functional layers on the electro-mechanical response of composite piezoresistive nano cantilever sensors. Systematic and detailed computations are performed using theoretical models and numerical simulations. Results show that both the isolation and immobilization layers play a critical role in governing the sensor performance. Simulation results depict that compared to a sensor with an isolation layer of thickness 100 nm, a sensor without isolation layer has 36.29% and 42.51% better deflection sensitivity and electrical sensitivity respectively. Furthermore, it is found that when an immobilization layer of thickness 40 nm is added atop the isolation layer, the deflection sensitivity and electrical sensitivity reduces by 12.98% and 15.83% respectively. Through our investigation it is shown that the isolation and immobilization layers not only play a vital role in determining the stability and electro-mechanical response of the sensor but their negligence in the design stages can be detrimental. Apart from investigating the impact of the immobilization layer thickness, to model the sensor closer to real time operational conditions, we have performed analysis to understand the impact of non-uniformity in

  14. In-situ piezoresponse force microscopy cantilever mode shape profiling

    International Nuclear Information System (INIS)

    Proksch, R.

    2015-01-01

    The frequency-dependent amplitude and phase in piezoresponse force microscopy (PFM) measurements are shown to be a consequence of the Euler-Bernoulli (EB) dynamics of atomic force microscope (AFM) cantilever beams used to make the measurements. Changes in the cantilever mode shape as a function of changes in the boundary conditions determine the sensitivity of cantilevers to forces between the tip and the sample. Conventional PFM and AFM measurements are made with the motion of the cantilever measured at one optical beam detector (OBD) spot location. A single OBD spot location provides a limited picture of the total cantilever motion, and in fact, experimentally observed cantilever amplitude and phase are shown to be strongly dependent on the OBD spot position for many measurements. In this work, the commonly observed frequency dependence of PFM response is explained through experimental measurements and analytic theoretical EB modeling of the PFM response as a function of both frequency and OBD spot location on a periodically poled lithium niobate sample. One notable conclusion is that a common choice of OBD spot location—at or near the tip of the cantilever—is particularly vulnerable to frequency dependent amplitude and phase variations stemming from dynamics of the cantilever sensor rather than from the piezoresponse of the sample

  15. Accurate spring constant calibration for very stiff atomic force microscopy cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Grutzik, Scott J.; Zehnder, Alan T. [Field of Theoretical and Applied Mechanics, Cornell University, Ithaca, New York 14853 (United States); Gates, Richard S.; Gerbig, Yvonne B.; Smith, Douglas T.; Cook, Robert F. [Nanomechanical Properties Group, Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    2013-11-15

    There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included.

  16. Accurate spring constant calibration for very stiff atomic force microscopy cantilevers

    International Nuclear Information System (INIS)

    Grutzik, Scott J.; Zehnder, Alan T.; Gates, Richard S.; Gerbig, Yvonne B.; Smith, Douglas T.; Cook, Robert F.

    2013-01-01

    There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included

  17. Magnetic force driven magnetoelectric effect in bi-cantilever composites

    Science.gov (United States)

    Zhang, Ru; Wu, Gaojian; Zhang, Ning

    2017-12-01

    The magnetic force driven magnetoelectric (ME) effect in bi-cantilever Mn-Zn-Ferrite /PZT composites is presented. Compared with single cantilever, the ME voltage coefficient in bi-cantilever composite is a little lower and the resonance frequency is higher, but the bi-cantilever structure is advantageous for integration. When the magnetic gap is 3 mm, the ME voltage coefficient can achieve 6.2 Vcm-1Oe-1 at resonance under optimum bias field Hm=1030 Oe; when the magnetic gap is 1.5 mm, the ME voltage coefficient can get the value as high as 4.4 Vcm-1Oe-1 under much lower bias field H=340 Oe. The stable ME effect in bi-cantilever composites has important potential application in the design of new type ME device.

  18. Comparison of Total Arch and Partial Arch Transposition During Hybrid Endovascular Repair for Aortic Arch Disease.

    Science.gov (United States)

    Kang, W C; Ko, Y-G; Oh, P C; Shin, E K; Park, C-H; Choi, D; Youn, Y N; Lee, D Y

    2016-08-01

    Total arch transposition (TAT) during hybrid endovascular repair for aortic arch disease is believed to allow a better landing zone, but also to be associated with higher peri-operative mortality than partial arch transposition (PAT). Information on this issue is limited. This study was a retrospective analysis. All 53 consecutive patients with aortic arch disease (41 males, mean age 65.0 years) who underwent hybrid endovascular repair with TAT (zone 0, n=20) or PAT (zone 1 or 2, n=33) from 2008 to 2014 were analyzed retrospectively. The peri-operative and late outcomes of these two groups were compared. Baseline characteristics, including EuroSCORE II results, were similar in the two groups. After procedures, peri-operative mortalities and stroke rates were similar in the two groups (5.0% vs. 9.1%, p=1.000, and 10.0% vs. 6.1%, p=.627). Interestingly, all four strokes occurred in patients with a type III aortic arch irrespective of transposition type. Primary success rates (80.0% vs. 69.7%, p=.527) and type I endoleak incidences (20.0% vs. 27.3%, p=.744) were not significantly different. During follow up (mean duration 36.9 months), overall survival (89.7% vs. 87.4% at 1 year and 89.7% vs. 79.3% at 3 years; p=.375) and re-intervention free survival rates (78.6% vs. 92.0% at 1 year; 72.0% vs. 62.2% at 3 years, p=.872) were similar in the two groups. Morbidity and mortality were high within the first year of hybrid endovascular therapy for aortic arch disease, implying that candidates for hybrid procedures need to be selected carefully. Hybrid endovascular repair with TAT was found to have peri-operative mortality, stroke, and long-term survival rates comparable with PAT, so hybrid endovascular repair may be considered, irrespective of type of arch reconstruction, when clinically indicated. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Drift study of SU8 cantilevers in liquid and gaseous environments.

    Science.gov (United States)

    Tenje, Maria; Keller, Stephan; Dohn, Søren; Davis, Zachary J; Boisen, Anja

    2010-05-01

    We present a study of the drift, in terms of cantilever deflections without probe/target interactions, of polymeric SU8 cantilevers. The drift is measured in PBS buffer (pH 7.4) and under vacuum (1mbar) conditions. We see that the cantilevers display a large drift in both environments. We believe this is because the polymer matrix absorbs liquid in one situation whereas it is being degassed in the other. An inhomogeneous expansion/contraction of the cantilever is seen because one surface of the cantilever may still have remains of the release layer from the fabrication. To further study the effect, we coat the cantilevers with a hydrophobic coating, perfluorodecyltrichlorosilane (FDTS). Fully encapsulating the SU8 cantilever greatly reduces the drift in liquid whereas a less significant change is seen in vacuum.

  20. Drift study of SU8 cantilevers in liquid and gaseous environments

    DEFF Research Database (Denmark)

    Tenje, Maria; Keller, Stephan Sylvest; Dohn, Søren

    2010-01-01

    We present a study of the drift, in terms of cantilever deflections without probe/target interactions, of polymeric SU8 cantilevers. The drift is measured in PBS buffer (pH 7.4) and under vacuum (1 mbar) conditions. We see that the cantilevers display a large drift in both environments. We believe...... coat the cantilevers with a hydrophobic coating, perfluorodecyltrichlorosilane (FDTS). Fully encapsulating the SU8 cantilever greatly reduces the drift in liquid whereas a less significant change is seen in vacuum....... this is because the polymer matrix absorbs liquid in one situation whereas it is being degassed in the other. An inhomogeneous expansion/contraction of the cantilever is seen because one surface of the cantilever may still have remains of the release layer from the fabrication. To further study the effect, we...

  1. A 2D panoramic surgical stent imaging: Complete arch mandibular implant fixed prosthesis along with bar supported maxillary over denture

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2017-01-01

    Full Text Available Successful rehabilitation of a patient should restore function, esthetic, and speech by prosthesis. Treatment modalities vary from patient to patient. Semi-precision attachments and implants offer several advantages over the traditional approach. The aim and objective of this report was to assess a case of a 55-year-old female patient who had lost all her teeth, except maxillary canines #13 and #23 and with severe bone loss in the mandible. Tooth-supported bar attachment was planned for maxilla, and a total of five dental implants were placed in the mandible using a flapless approach aided by radiographic gutta-percha surgical stents over panoramic two-dimensional imaging. Customized, radiographic stents help for the placement of implant in the view of paralleling and flapless surgery, completely. An immediate loading protocol is adopted as from day of the surgery to 6 weeks along with implant supported full arch fixed dentures after 4 months. The outcome of the treatment was impressive, and the patient gave a positive response with superb esthetics and functions.

  2. Persistent fifth arch anomalies - broadening the spectrum to include a variation of double aortic arch vascular ring

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Chan, Frandics [Stanford Children' s Hospital and Stanford University, Department of Radiology, Stanford, CA (United States); Hanneman, Kate [University of Toronto, Department of Medical Imaging, Toronto, ON (Canada)

    2016-12-15

    Fifth arch anomalies are rare and complex and frequently misdiagnosed or mistaken for other entities. We report a double arch vascular ring that is thought to consist of right fourth arch and left fifth arch components, a previously undescribed persistent fifth arch variant. The currently recognized spectrum and classification of fifth arch vascular anomalies are expanded along with illustrative images to justify the proposed changes. Reviewing and expanding the classification of fifth arch anomalies to include a double arch ring variant will promote recognition, correct diagnosis and appropriate management of these anomalies. (orig.)

  3. Micro‑cantilevers for optical sensing of biogenic amines

    DEFF Research Database (Denmark)

    Wang, Ying; Bravo Costa, Carlos André; Sobolewska, Elżbieta Karolina

    2017-01-01

    molecules in the gas phase. Different functionalization conditions were investigated by immersing gold coated AFM cantilevers in cyclam solutions at different concentrations, for different functionalization times, and for different post-annealing treatments. The optimum morphology for high capture...... micro-cantilever based mass detection. We demonstrate that besides conventional AFM systems a MEMS cantilever in combination with an optical read out is a powerful analytic system which is highly attractive for widespread use in diagnostic applications, with optimized functionalization conditions...

  4. Fabrication of resonant micro cantilevers with integrated transparent fluidic channel

    DEFF Research Database (Denmark)

    Khan, Faheem; Schmid, Silvan; Davis, Zachary James

    2011-01-01

    Microfabricated cantilevers are proving their potential as excellent tools for analysis applications. In this paper, we describe the design, fabrication and testing of resonant micro cantilevers with integrated transparent fluidic channels. The cantilevers have been devised to measure the density...

  5. Self-heating in piezoresistive cantilevers.

    Science.gov (United States)

    Doll, Joseph C; Corbin, Elise A; King, William P; Pruitt, Beth L

    2011-05-30

    We report experiments and models of self-heating in piezoresistive microcantilevers that show how cantilever measurement resolution depends on the thermal properties of the surrounding fluid. The predicted cantilever temperature rise from a finite difference model is compared with detailed temperature measurements on fabricated devices. Increasing the fluid thermal conductivity allows for lower temperature operation for a given power dissipation, leading to lower force and displacement noise. The force noise in air is 76% greater than in water for the same increase in piezoresistor temperature.

  6. Improving tapping mode atomic force microscopy with piezoelectric cantilevers

    International Nuclear Information System (INIS)

    Rogers, B.; Manning, L.; Sulchek, T.; Adams, J.D.

    2004-01-01

    This article summarizes improvements to the speed, simplicity and versatility of tapping mode atomic force microscopy (AFM). Improvements are enabled by a piezoelectric microcantilever with a sharp silicon tip and a thin, low-stress zinc oxide (ZnO) film to both actuate and sense deflection. First, we demonstrate self-sensing tapping mode without laser detection. Similar previous work has been limited by unoptimized probe tips, cantilever thicknesses, and stress in the piezoelectric films. Tests indicate self-sensing amplitude resolution is as good or better than optical detection, with double the sensitivity, using the same type of cantilever. Second, we demonstrate self-oscillating tapping mode AFM. The cantilever's integrated piezoelectric film serves as the frequency-determining component of an oscillator circuit. The circuit oscillates the cantilever near its resonant frequency by applying positive feedback to the film. We present images and force-distance curves using both self-sensing and self-oscillating techniques. Finally, high-speed tapping mode imaging in liquid, where electric components of the cantilever require insulation, is demonstrated. Three cantilever coating schemes are tested. The insulated microactuator is used to simultaneously vibrate and actuate the cantilever over topographical features. Preliminary images in water and saline are presented, including one taken at 75.5 μm/s - a threefold improvement in bandwidth versus conventional piezotube actuators

  7. Nonlinear mathematical modeling of vibrating motion of nanomechanical cantilever active probe

    Directory of Open Access Journals (Sweden)

    Reza Ghaderi

    Full Text Available Nonlinear vibration response of nanomechanical cantilever (NMC active probes in atomic force microscope (AFM application has been studied in the amplitude mode. Piezoelectric layer is placed piecewise and as an actuator on NMC. Continuous beam model has been chosen for analysis with regard to the geometric discontinuities of piezoelectric layer attachment and NMC's cross section. The force between the tip and the sample surface is modeled using Leonard-Jones potential. Assuming that cantilever is inclined to the sample surface, the effect of nonlinear force on NMC is considered as a shearing force and the concentrated bending moment is regarded at the end. Nonlinear frequency response of NMC is obtained close to the sample surface using the dynamic modeling. It is then become clear that the distance and angle of NMC, the probe length, and the geometric dimensions of piezoelectric layer can affect frequency response bending of the curve.

  8. Integrated optical readout for miniaturization of cantilever-based sensor system

    DEFF Research Database (Denmark)

    Nordström, Maria; Zauner, Dan; Calleja, Montserrat

    2007-01-01

    The authors present the fabrication and characterization of an integrated optical readout scheme based on single-mode waveguides for cantilever-based sensors. The cantilever bending is read out by monitoring changes in the optical intensity of light transmitted through the cantilever that also acts...

  9. Cantilevers orthodontics forces measured by fiber sensors

    Science.gov (United States)

    Schneider, Neblyssa; Milczewski, Maura S.; de Oliveira, Valmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-09-01

    Fibers Bragg Gratings were used to evaluate the transmission of the forces generates by orthodontic mechanic based one and two cantilevers used to move molars to the upright position. The results showed levels forces of approximately 0,14N near to the root of the molar with one and two cantilevers.

  10. Development of an Electrochemical-Cantilever Hybrid Platform

    DEFF Research Database (Denmark)

    Fischer, Lee MacKenzie

    . For at binde kobber (II) ioner blev rækker af cantilevere funktionaliseret med aminosyre L-cysteine(Cys) og tetrapeptid Cys-Gly-Gly-His (CGGH). Dette funktionelle lag blev fjernet fra en enkelt cantilever, ved selektivt at anvende et voltammetrisk signal til at generere en ren reference cantilever til brug...

  11. Electrostatic force microscopy with a self-sensing piezoresistive cantilever

    International Nuclear Information System (INIS)

    Pi, U. H.; Kye, J. I.; Shin, S.; Khim, Z. G.; Hong, J. W.; Yoon, S.

    2003-01-01

    We present a new method for electrostatic force microscopy (EFM) using a piezoresistive cantilever instead of the conventional cantilever with an optical detector. In EFM with a piezoresistive cantilever, the electrostatic force between the tip and the sample is monitored by sensing the change in the resistance of the piezoresistive cantilever at a frequency of several tens of kHz. A large stray capacitance effect can be rejected by using an appropriate phase tuning of the phase-sensitive detection. We observed the ferroelectric domain images of a triglycine sulfate single crystal. We could also write fine patterns on a lead-zirconate-titanate (PZT) thin film through domain reversal by applying various dc voltages between the tip and the sample. We suggest that the EFM technique using a self-sensing and self-actuating piezoresistive cantilever can be applied to a high-density data storage field

  12. Nanomechanics of layer-by-layer polyelectrolyte complexes: a manifestation of ionic cross-links and fixed charges.

    Science.gov (United States)

    Han, Biao; Chery, Daphney R; Yin, Jie; Lu, X Lucas; Lee, Daeyeon; Han, Lin

    2016-01-28

    This study investigates the roles of two distinct features of ionically cross-linked polyelectrolyte networks - ionic cross-links and fixed charges - in determining their nanomechanical properties. The layer-by-layer assembled poly(allylamine hydrochloride)/poly(acrylic acid) (PAH/PAA) network is used as the model material. The densities of ionic cross-links and fixed charges are modulated through solution pH and ionic strength (IS), and the swelling ratio, elastic and viscoelastic properties are quantified via an array of atomic force microscopy (AFM)-based nanomechanical tools. The roles of ionic cross-links are underscored by the distinctive elastic and viscoelastic nanomechanical characters observed here. First, as ionic cross-links are highly sensitive to solution conditions, the instantaneous modulus, E0, exhibits orders-of-magnitude changes upon pH- and IS-governed swelling, distinctive from the rubber elasticity prediction based on permanent covalent cross-links. Second, ionic cross-links can break and self-re-form, and this mechanism dominates force relaxation of PAH/PAA under a constant indentation depth. In most states, the degree of relaxation is >90%, independent of ionic cross-link density. The importance of fixed charges is highlighted by the unexpectedly more elastic nature of the network despite low ionic cross-link density at pH 2.0, IS 0.01 M. Here, the complex is a net charged, loosely cross-linked, where the degree of relaxation is attenuated to ≈50% due to increased elastic contribution arising from fixed charge-induced Donnan osmotic pressure. In addition, this study develops a new method for quantifying the thickness of highly swollen polymer hydrogel films. It also underscores important technical considerations when performing nanomechanical tests on highly rate-dependent polymer hydrogel networks. These results provide new insights into the nanomechanical characters of ionic polyelectrolyte complexes, and lay the ground for further

  13. Optimization of sensitivity and noise in piezoresistive cantilevers

    DEFF Research Database (Denmark)

    Yu, Xiaomei; Thaysen, Jacob; Hansen, Ole

    2002-01-01

    In this article, the sensitivity and the noise of piezoresistive cantilevers were systematically investigated with respect to the piezoresistor geometry, the piezoresistive materials, the doping dose, the annealing temperature, and the operating biased voltage. With the noise optimization results......(-6), the biggest gauge factors was 95, and the minimum detectable deflection (MDD) at 6 V and 200 Hz-measurement bandwidth was 0.3 nm for a single-crystal silicon cantilever. Of the two LPCVD silicon piezoresistive cantilevers, amorphous silicon piezoresistors had relatively lower 1/f noise. The MDD for a LPCVD...

  14. Surgical modification for preventing a gothic arch after aortic arch repair without the use of foreign material.

    Science.gov (United States)

    Seo, Dong-Man; Park, Jiyoung; Goo, Hyun Woo; Kim, Young Hwue; Ko, Jae-Kon; Jhang, Won Kyoung

    2015-04-01

    Systemic hypertension is the main late complication after arch reconstruction in patients with arch obstruction. Gothic arch geometry is suspected to be one of its possible causes. Accordingly, we evaluated here if a modified arch repair technique using an autologous pulmonary patch is effective in preventing gothic arch development. Fifty infants who underwent arch repair with either a modified (n = 17) or conventional (n = 33) technique between January 2006 and August 2012 by a single surgeon were retrospectively reviewed. Arch geometry was compared using three categories (gothic, crenel or roman), classified by the height/width (H/W) ratio and the arch angle measured in computed tomography. No gothic arch geometry was observed in the modified group, whereas it was observed in 9 cases in the conventional group (P = 0.005). Moreover, reintervention for arch restenosis was performed only in the conventional group (n = 4; P = 0.29). No associated complications were observed, although the selective cerebral perfusion time was longer in the modified group than in the conventional group (28.5 ± 6.2 vs 17.1 ± 9.9 min; P gothic arch geometry, but also as equally safe in terms of early clinical outcomes as conventional arch reconstruction techniques. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. RARE BRANCHIAL ARCH ANOMALIES

    Directory of Open Access Journals (Sweden)

    Jayanta Kumar

    2016-03-01

    Full Text Available AIM Amongst the branchial arch anomalies third arch anomaly occurs rarely and more so the fourth arch anomalies. We present our experience with cases of rare branchial arch anomalies. PATIENTS AND METHODS From June 2006 to January 2016, cases having their external opening in the lower third of sternocleidomastoid muscle with the tract going through thyroid gland and directing to pyriform sinus (PFS or cysts with internal opening in the PFS were studied. RESULTS No fourth arch anomaly was encountered. One cyst with internal opening which later on formed a fistula, three fistulae from beginning and two sinuses were encountered. The main stay of diagnosis was the fistula in the PFS and the tract lying posterior to the internal carotid artery. Simple excision technique with a small incision around the external opening was done. There was no recurrence. CONCLUSION Third arch fistula is not very rare as it was thought. Internal fistula is found in most of the cases. Though radiological investigations are helpful, fistulae can be diagnosed clinically and during operation. Extensive operation of the neck, mediastinum and pharynx is not required.

  16. Resonance frequencies of AFM cantilevers in contact with a surface

    Energy Technology Data Exchange (ETDEWEB)

    Verbiest, G.J., E-mail: Verbiest@physik.rwth-aachen.de [JARA-FIT and II. Institute of Physics, RWTH Aachen University, 52074 Aachen (Germany); Rost, M.J., E-mail: Rost@physics.leidenuniv.nl [Huygens-Kamerlingh Onnes Laboratory, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands)

    2016-12-15

    To make the forces in an Atomic Force Microscope that operates in a dynamic mode with one or multiple vibrations applied to the cantilever, quantitative, one needs to relate a change in resonance frequency of the cantilever to a specific tip–sample interaction. Due to the time dependence of the force between the tip and sample caused by the vibrations, this task is not only difficult, but in fact only possible to solve for certain limiting cases, if one follows common theoretical approaches with a Taylor expansion around the deflection point. Here, we present an analytical method for calculating the resonance frequencies of the cantilever that is valid for any tip–sample interaction. Instead of linearizing the tip–sample interaction locally, we calculate an averaged, weighted linearization taking into account all positions of the tip while vibrating. Our method bridges, therefore, the difficult gap between a free oscillating cantilever and a cantilever that is pushed infinitely hard into contact with a surface, which describes a clamped-pinned boundary condition. For a correct description of the cantilever dynamics, we take into account both the tip mass and the tip moment of inertia. Applying our model, we show that it is possible to calculate the modal response of a cantilever as a function of the tip–sample interaction strength. Based on these modal vibration characteristics, we show that the higher resonance frequencies of a cantilever are completely insensitive to the strength of the tip–sample interaction. - Highlights: • A method to calculate the resonances of AFM cantilevers under any force is proposed. • The analytical model is based on Euler-beam theory. • The shift in resonance frequency due to forces decrease with increasing mode number. • The proposed method enables quantitative ultrasound AFM experiments. • Our results explain also the applicability of the higher modes in SubSurface-AFM.

  17. Application of a Cantilevered SWCNT with Mass at the Tip as a Nanomechanical Sensor

    DEFF Research Database (Denmark)

    Mehdipour, I.; Barari, Amin; Domairry, G.

    2011-01-01

    In this paper, the continuum mechanics method and a bending model is applied to obtain the resonant frequency of the fixed-free SWCNT where the mass is rigidly attached to the tip. This method used the Euler–Bernoulli theory with cantilevered boundary conditions where the effect of attached mass ...... of resonant frequency are decreased. The validity and the accuracy of these formulas are examined with other sensor equations in the literatures. The results indicate that the new sensor equations can be used for CNT like CNT-based biosensors with reasonable accuracy....

  18. Micromechanical testing of SU-8 cantilevers

    OpenAIRE

    Hopcroft, M; Kramer, T; Kim, G; Takashima, K; Higo, Y; Moore, D; Brugger, J

    2005-01-01

    SU-8 is a photoplastic polymer with a wide range of possible applications in microtechnology. Cantilevers designed for atomic force microscopes were fabricated in SU-8. The mechanical properties of these cantilevers were investigated using two microscale testing techniques: contact surface profilometer beam deflection and static load deflection at a point on the beam using a specially designed test machine. The SU-8 Young's modulus value from the microscale test methods is approximately 2-3 GPa.

  19. Cantilever-based micro-particle filter with simultaneous single particle detection

    DEFF Research Database (Denmark)

    Noeth, Nadine-Nicole; Keller, Stephan Sylvest; Boisen, Anja

    2011-01-01

    Currently, separation of whole blood samples on lab-on-a-chip systems is achieved via filters followed by analysis of the filtered matter such as counting of blood cells. Here, a micro-chip based on cantilever technology is developed, which enables simultaneous filtration and counting of micro-particles...... from a liquid. A hole-array is integrated into a micro-cantilever, which is inserted into a microfluidic channel perpendicular to the flow. A metal pad at the apex of the cantilever enables an optical read-out of the deflection of the cantilever. When a micro-particle is too large to pass a hole...

  20. Design & fabrication of cantilever array biosensors

    DEFF Research Database (Denmark)

    Boisen, Anja; Thundat, T

    2009-01-01

    Surface immobilization of functional receptors on microfabricated cantilever arrays offers a new paradigm for the development of biosensors based on nanomechanics. Microcantilever-based systems are capable of real-time, multiplexed detection of unlabeled disease markers in extremely small volumes......, electronic processing, and even local telemetry on a single chip have the potential of satisfying the need for highly sensitive and selective multiple-target detection in very small samples. Here we will review the design and fabrication process of cantilever-based biosensors....

  1. Cable strengthened arches

    NARCIS (Netherlands)

    Kamerling, M.W.

    2013-01-01

    The structural efficiency of arches, subjected to several variable loads, can be increased by strengthening these arches with cables. For these structures it can be necessary, especially in case the permanent load is small, to post-tension the cables to avoid any compression acting on the cables. A

  2. Mandibular canine intrusion with the segmented arch technique: A finite element method study.

    Science.gov (United States)

    Caballero, Giselle Milagros; Carvalho Filho, Osvaldo Abadia de; Hargreaves, Bernardo Oliveira; Brito, Hélio Henrique de Araújo; Magalhães Júnior, Pedro Américo Almeida; Oliveira, Dauro Douglas

    2015-06-01

    Mandibular canines are anatomically extruded in approximately half of the patients with a deepbite. Although simultaneous orthodontic intrusion of the 6 mandibular anterior teeth is not recommended, a few studies have evaluated individual canine intrusion. Our objectives were to use the finite element method to simulate the segmented intrusion of mandibular canines with a cantilever and to evaluate the effects of different compensatory buccolingual activations. A finite element study of the right quadrant of the mandibular dental arch together with periodontal structures was modeled using SolidWorks software (Dassault Systèmes Americas, Waltham, Mass). After all bony, dental, and periodontal ligament structures from the second molar to the canine were graphically represented, brackets and molar tubes were modeled. Subsequently, a 0.021 × 0.025-in base wire was modeled with stainless steel properties and inserted into the brackets and tubes of the 4 posterior teeth to simulate an anchorage unit. Finally, a 0.017 × 0.025-in cantilever was modeled with titanium-molybdenum alloy properties and inserted into the first molar auxiliary tube. Discretization and boundary conditions of all anatomic structures tested were determined with HyperMesh software (Altair Engineering, Milwaukee, Wis), and compensatory toe-ins of 0°, 4°, 6°, and 8° were simulated with Abaqus software (Dassault Systèmes Americas). The 6° toe-in produced pure intrusion of the canine. The highest amounts of periodontal ligament stress in the anchor segment were observed around the first molar roots. This tooth showed a slight tendency for extrusion and distal crown tipping. Moreover, the different compensatory toe-ins tested did not significantly affect the other posterior teeth. The segmented mechanics simulated in this study may achieve pure mandibular canine intrusion when an adequate amount of compensatory toe-in (6°) is incorporated into the cantilever to prevent buccal and lingual crown

  3. A Review on Surface Stress-Based Miniaturized Piezoresistive SU-8 Polymeric Cantilever Sensors

    Science.gov (United States)

    Mathew, Ribu; Ravi Sankar, A.

    2018-06-01

    In the last decade, microelectromechanical systems (MEMS) SU-8 polymeric cantilevers with piezoresistive readout combined with the advances in molecular recognition techniques have found versatile applications, especially in the field of chemical and biological sensing. Compared to conventional solid-state semiconductor-based piezoresistive cantilever sensors, SU-8 polymeric cantilevers have advantages in terms of better sensitivity along with reduced material and fabrication cost. In recent times, numerous researchers have investigated their potential as a sensing platform due to high performance-to-cost ratio of SU-8 polymer-based cantilever sensors. In this article, we critically review the design, fabrication, and performance aspects of surface stress-based piezoresistive SU-8 polymeric cantilever sensors. The evolution of surface stress-based piezoresistive cantilever sensors from solid-state semiconductor materials to polymers, especially SU-8 polymer, is discussed in detail. Theoretical principles of surface stress generation and their application in cantilever sensing technology are also devised. Variants of SU-8 polymeric cantilevers with different composition of materials in cantilever stacks are explained. Furthermore, the interdependence of the material selection, geometrical design parameters, and fabrication process of piezoresistive SU-8 polymeric cantilever sensors and their cumulative impact on the sensor response are also explained in detail. In addition to the design-, fabrication-, and performance-related factors, this article also describes various challenges in engineering SU-8 polymeric cantilevers as a universal sensing platform such as temperature and moisture vulnerability. This review article would serve as a guideline for researchers to understand specifics and functionality of surface stress-based piezoresistive SU-8 cantilever sensors.[Figure not available: see fulltext.

  4. SU-8 Cantilever Sensor with Integrated Read-Out

    DEFF Research Database (Denmark)

    Johansson, Alicia Charlotte

    2007-01-01

    Cantilever baserede biosensorer kan bruges til så kaldet label-free detektion af små koncentrationer af molekyler i en opløsning. Når et specifikt molekyle binder til overfladen af en cantilever induceres et overfladestress som resulterer i en udbøjning af cantileveren. Cantileverens udbøjningen ...

  5. Simple kinetic theory model of reactive collisions. IV. Laboratory fixed orientational cross sections

    International Nuclear Information System (INIS)

    Evans, G.T.

    1987-01-01

    The differential orientational cross section, obtainable from molecular beam experiments on aligned molecules, is calculated using the line-of-normals model for reactive collisions involving hard convex bodies. By means of kinetic theory methods, the dependence of the cross section on the angle of attack γ 0 is expressed in a Legendre function expansion. Each of the Legendre expansion coefficients is given by an integral over the molecule-fixed cross section and functions of the orientation dependent threshold energy

  6. FEATURES OF DESIGN OF TIED-ARCH BRIDGES WITH FLEXIBLE INCLINED SUSPENSION HANGERS

    Directory of Open Access Journals (Sweden)

    V. O. Samosvat

    2017-10-01

    Full Text Available Purpose. Investigation and analysis of the hanger arrangement and the structural stability of a Network arch bridge – a tied-arch bridge with inclined hangers that cross each other at least twice. It is also necessary to make a comparative analysis with other types of hanger arrangements. Methodology. The authors in their research investigated a large number of parameters to determine their influence in the force distribution in the arch. Eventually they determined optimal values for all parameters. These optimal values allowed developing a design guide that leads to optimal arch design. When solving this problem, the authors used three-dimensional finite element models and the objective was to determine the most suitable solution for a road bridge, with a span of 100 meters, consisting of two inclined steel arches, located on a road with two traffic lanes, subjected to medium traffic. The virtual prototype of the model is performed by finite element simulator Midas Civil. Findings. In this study, for the bridge deck, a concrete tie appears to be the best solution considering the structural behavior of network arches, but economic advantages caused by easier erection may lead to steel or a composite bridge deck as better alternatives. Design requirements and local conditions of each particular bridge project will decide the most economic deck design.Originality. To ensure passenger comfort and the stability and continuity of the track, deformations of bridges are constricted. A network arch is a stiff structure with small deflections and therefore suitable to comply with such demands even for high speed railway traffic.
A network arch bridge with a concrete tie usually saves more than half the steel required for tied arches with vertical hangers and concrete ties. Practical value. Following the study design advice given in this article leads to savings of about 60 % of structural steel compared with conventional tied arch bridges with

  7. Microstructure cantilever beam for current measurement

    Directory of Open Access Journals (Sweden)

    M.T.E. Khan

    2010-01-01

    Full Text Available Most microelectromechanical systems (MEMS sensors are based on the microcantilever technology, which uses a broad range of design materials and structures. The benefit ofMEMStechnology is in developing devices with a lower cost, lower power consumption, higher performance and greater integration. A free-end cantilever beam with a magnetic material mass has been designed using MEMS software tools. The magnetic material was used to improve the sensitivity of the cantilever beam to an externally-applied magnetic field. The cantilever was designed to form a capacitance transducer, which consisted of variable capacitance where electrical and mechanical energies were exchanged. The aim of this paper was to analyse the system design of the microcantilever when subjected to a magnetic field produced by a current-carrying conductor. When the signal, a sinusoidal current with a constant frequency, was applied, the cantilever beam exhibited a vibration motion along the vertical axis when placed closer to the line current. This motion created corresponding capacitance changes and generated a voltage output proportional to the capacitive change in the signal-processing circuitry attached to the microcantilever. The equivalent massspring system theory was used to describe and analyse the effect of the natural frequency of the system vibrations and motion due to the applied magnetic field, in a single-degree of freedom. The main application of this microcantilever is in current measurements to develop a non-contact current sensor mote.

  8. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique.

    Science.gov (United States)

    Kairalla, Silvana Allegrini; Scuzzo, Giuseppe; Triviño, Tarcila; Velasco, Leandro; Lombardo, Luca; Paranhos, Luiz Renato

    2014-01-01

    This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D) and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25%)--an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%). T-test revealed differences between males and females in the size of 12 dental arches. The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  9. SU-8 hollow cantilevers for AFM cell adhesion studies

    Science.gov (United States)

    Martinez, Vincent; Behr, Pascal; Drechsler, Ute; Polesel-Maris, Jérôme; Potthoff, Eva; Vörös, Janos; Zambelli, Tomaso

    2016-05-01

    A novel fabrication method was established to produce flexible, transparent, and robust tipless hollow atomic force microscopy (AFM) cantilevers made entirely from SU-8. Channels of 3 μm thickness and several millimeters length were integrated into 12 μm thick and 40 μm wide cantilevers. Connected to a pressure controller, the devices showed high sealing performance with no leakage up to 6 bars. Changing the cantilever lengths from 100 μm to 500 μm among the same wafer allowed the targeting of various spring constants ranging from 0.5 to 80 N m-1 within a single fabrication run. These hollow polymeric AFM cantilevers were operated in the optical beam deflection configuration. To demonstrate the performance of the device, single-cell force spectroscopy experiments were performed with a single probe detaching in a serial protocol more than 100 Saccharomyces cerevisiae yeast cells from plain glass and glass coated with polydopamine while measuring adhesion forces in the sub-nanoNewton range. SU-8 now offers a new alternative to conventional silicon-based hollow cantilevers with more flexibility in terms of complex geometric design and surface chemistry modification.

  10. SU-8 hollow cantilevers for AFM cell adhesion studies

    International Nuclear Information System (INIS)

    Martinez, Vincent; Behr, Pascal; Vörös, Janos; Zambelli, Tomaso; Drechsler, Ute; Polesel-Maris, Jérôme; Potthoff, Eva

    2016-01-01

    A novel fabrication method was established to produce flexible, transparent, and robust tipless hollow atomic force microscopy (AFM) cantilevers made entirely from SU-8. Channels of 3 μm thickness and several millimeters length were integrated into 12 μm thick and 40 μm wide cantilevers. Connected to a pressure controller, the devices showed high sealing performance with no leakage up to 6 bars. Changing the cantilever lengths from 100 μm to 500 μm among the same wafer allowed the targeting of various spring constants ranging from 0.5 to 80 N m −1 within a single fabrication run. These hollow polymeric AFM cantilevers were operated in the optical beam deflection configuration. To demonstrate the performance of the device, single-cell force spectroscopy experiments were performed with a single probe detaching in a serial protocol more than 100 Saccharomyces cerevisiae yeast cells from plain glass and glass coated with polydopamine while measuring adhesion forces in the sub-nanoNewton range. SU-8 now offers a new alternative to conventional silicon-based hollow cantilevers with more flexibility in terms of complex geometric design and surface chemistry modification. (paper)

  11. Multi-directional energy harvesting by piezoelectric cantilever-pendulum with internal resonance

    Energy Technology Data Exchange (ETDEWEB)

    Xu, J.; Tang, J., E-mail: jtang@engr.uconn.edu [Department of Mechanical Engineering, The University of Connecticut, Storrs, Connecticut 06269 (United States)

    2015-11-23

    This letter reports a piezoelectric cantilever-pendulum design for multi-directional energy harvesting. A pendulum is attached to the tip of a piezoelectric cantilever-type energy harvester. This design aims at taking advantage of the nonlinear coupling between the pendulum motion in 3-dimensional space and the beam bending vibration at resonances. Experimental studies indicate that, under properly chosen parameters, 1:2 internal resonance can be induced, which enables the multi-directional energy harvesting with a single cantilever. The advantages of the design with respect to traditional piezoelectric cantilever are examined.

  12. Multi-directional energy harvesting by piezoelectric cantilever-pendulum with internal resonance

    International Nuclear Information System (INIS)

    Xu, J.; Tang, J.

    2015-01-01

    This letter reports a piezoelectric cantilever-pendulum design for multi-directional energy harvesting. A pendulum is attached to the tip of a piezoelectric cantilever-type energy harvester. This design aims at taking advantage of the nonlinear coupling between the pendulum motion in 3-dimensional space and the beam bending vibration at resonances. Experimental studies indicate that, under properly chosen parameters, 1:2 internal resonance can be induced, which enables the multi-directional energy harvesting with a single cantilever. The advantages of the design with respect to traditional piezoelectric cantilever are examined

  13. Fracture Characteristics Analysis of Double-layer Rock Plates with Both Ends Fixed Condition

    Directory of Open Access Journals (Sweden)

    S. R. Wang

    2014-07-01

    Full Text Available In order to research on the fracture and instability characteristics of double-layer rock plates with both ends fixed, the three-dimension computational model of double-layer rock plates under the concentrated load was built by using PFC3D technique (three-dimension particle flow code, and the mechanical parameters of the numerical model were determined based on the physical model tests. The results showed the instability process of the double-layer rock plates had four mechanical response phases: the elastic deformation stage, the brittle fracture of upper thick plate arching stage, two rock-arch bearing stage and two rock-arch failure stage; moreover, with the rock plate particle radius from small to large change, the maximum vertical force of double rock-arch appeared when the particle size was a certain value. The maximum vertical force showed an upward trend with the increase of the rock plate temperature, and in the case of the same thickness the maximum vertical force increased with the increase of the upper rock plate thickness. When the boundary conditions of double-layer rock plates changed from the hinged support to the fixed support, the maximum horizontal force observably decreased, and the maximum vertical force showed small fluctuations and then tended towards stability with the increase of cohesive strength of double-layer rock plates.

  14. Polymer cantilever platform for dielectrophoretic assembly of carbon nanotubes

    DEFF Research Database (Denmark)

    Johansson, Alicia; Calleja, M.; Dimaki, Maria

    2004-01-01

    A polymer cantilever platform for dielectrophoretic assembly of carbon nanotubes has been designed and realized. Multi-walled carbon nanotubes from aqueous solution have been assembled between two metal electrodes that are separated by 2 mu m and embedded in the polymer cantilever. The entire chip......, except for the metallic electrodes and wiring, was fabricated in the photoresist SU-8. SU-8 allows for an inexpensive, flexible and fast fabrication method, and the cantilever platform provides a hydrophobic surface that should be well suited for nanotube assembly. The device can be integrated in a micro...

  15. Aortic arch malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kellenberger, Christian J. [University Children' s Hospital, Department of Diagnostic Imaging, Zuerich (Switzerland)

    2010-06-15

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  16. Aortic arch malformations

    International Nuclear Information System (INIS)

    Kellenberger, Christian J.

    2010-01-01

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  17. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers

    International Nuclear Information System (INIS)

    Yeh, M.-K.; Tai, N.-Ha; Chen, B.-Y.

    2008-01-01

    Atomic force microscopy (AFM) can be used to measure the surface morphologies and the mechanical properties of nanostructures. The force acting on the AFM cantilever can be obtained by multiplying the spring constant of AFM cantilever and the corresponding deformation. To improve the accuracy of force experiments, the spring constant of AFM cantilever must be calibrated carefully. Many methods, such as theoretical equations, the finite element method, and the use of reference cantilever, were reported to obtain the spring constant of AFM cantilevers. For the cantilever made of single crystal, the Poisson's ratio varies with different cantilever-crystal angles. In this paper, the influences of Poisson's ratio variation on the lateral spring constant and axial spring constant of rectangular and V-shaped AFM cantilevers, with different tilt angles and normal forces, were investigated by the finite element analysis. When the cantilever's tilt angle is 20 deg. and the Poisson's ratio varies from 0.02 to 0.4, the finite element results show that the lateral spring constants decrease 11.75% for the rectangular cantilever with 1 μN landing force and decrease 18.60% for the V-shaped cantilever with 50 nN landing force, respectively. The influence of Poisson's ratio variation on axial spring constant is less than 3% for both rectangular and V-shaped cantilevers. As the tilt angle increases, the axial spring constants for rectangular and V-shaped cantilevers decrease substantially. The results obtained can be used to improve the accuracy of the lateral force measurement when using atomic force microscopy

  18. Evaluation of arch width variations among different skeletal patterns in South Indian population.

    Science.gov (United States)

    Prasad, Mandava; Kannampallil, Senny Thomas; Talapaneni, Ashok Kumar; George, Suja Ani; Shetty, Sharath Kumar

    2013-01-01

    Anterior cranial base can be taken as a reference line (SN) to determine the steepness of mandibular plane. Subjects with high mandibular plane angle tend to have a long face and one with low MP-SN angle has a shorter face. This study was done to investigate if dental arch widths correlated with vertical facial types and if there are any differences in arch widths between untreated male and female adults in South Indian population. Lateral cephalogram and dental casts were obtained from 180 untreated South Indian adults (90 males and 90 females) above 18 year old with no cross bite, minimal crowding and spacing. The angle between the anterior cranial base and the mandibular plane was measured on lateral cephalogram of each patient. Dental casts were used to obtain comprehensive dental measurements including maxillary and mandibular inter canine, inter premolar and inter molar widths, as well as amount of crowding or spacing. The results showed that male arch widths were significantly larger than those of females (P population. The results obtained in our study when compared with studies done in other population groups showed that there is difference in inter arch widths according to ethnicity and race. It was concluded that the dental arch width is associated with gender, race and vertical facial morphology. Thus using individualized arch wires according to each patient's pre treatment arch form and width is suggested during orthodontic treatment.

  19. Innovative multi-cantilever array sensor system with MOEMS read-out

    Science.gov (United States)

    Ivaldi, F.; Bieniek, T.; Janus, P.; Grabiec, P.; Majstrzyk, W.; Kopiec, D.; Gotszalk, T.

    2016-11-01

    Cantilever based sensor system are a well-established sensor family exploited in several every-day life applications as well as in high-end research areas. The very high sensitivity of such systems and the possibility to design and functionalize the cantilevers to create purpose built and highly selective sensors have increased the interest of the scientific community and the industry in further exploiting this promising sensors type. Optical deflection detection systems for cantilever sensors provide a reliable, flexible method for reading information from cantilevers with the highest sensitivity. However the need of using multi-cantilever arrays in several fields of application such as medicine, biology or safety related areas, make the optical method less suitable due to its structural complexity. Working in the frame of a the Joint Undertaking project Lab4MEMS II our group proposes a novel and innovative approach to solve this issue, by integrating a Micro-Opto-Electro-Mechanical-System (MOEMS) with dedicated optics, electronics and software with a MOEMS micro-mirror, ultimately developed in the frame of Lab4MEMSII. In this way we are able to present a closely packed, lightweight solution combining the advantages of standard optical read-out systems with the possibility of recording multiple read-outs from large cantilever arrays quasi simultaneously.

  20. Occlusal stability in shortened dental arches.

    Science.gov (United States)

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  1. Estimation of Fractionally Integrated Panels with Fixed Effects and Cross-Section Dependence

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre; Velasco, Carlos

    We consider large N, T panel data models with fixed effects, common factors allowing cross-section dependence, and persistent data and shocks, which are assumed fractionally integrated. In a basic setup, the main interest is on the fractional parameter of the idiosyncratic component, which...

  2. The role of superstructure material on the stress distribution in mandibular full-arch implant-supported fixed dentures. A CT-based 3D-FEA.

    Science.gov (United States)

    Ferreira, Mayara Barbosa; Barão, Valentim Adelino; Faverani, Leonardo Perez; Hipólito, Ana Carolina; Assunção, Wirley Gonçalves

    2014-02-01

    This study evaluated the stress distribution in mandibular full-arch implant-supported fixed dentures with different veneering and metallic infrastructure materials, using three-dimensional finite element analysis. Ten models were obtained from an edentulous human mandible with a complete denture fixed by four implants. Acrylic resin (RES) and porcelain (POR) teeth were associated with infrastructures of titanium (Ti), gold (Au), silver-palladium (AgPd), chrome-cobalt (CoCr) and nickel-chrome (NiCr). A 100-N oblique was applied. The von Mises (σvM) and maximum (σmax) and minimum (σmin) principal stresses were obtained. The RES-AgPd group showed the lowest σvM values, while the RES-Ni-Cr group showed the highest. In the bone tissue, the RES-Au group was the only one that showed different σmax values with a 12% increase in comparison to the other groups which had similar stress values. In the implants, the groups with Ti, Au and AgPd infrastructures, either with porcelain or resin teeth, showed σvM values similar and lower in comparison to the groups with CoCr and NiCr infrastructures. The tooth veneering material influenced the stress values in metallic infrastructures, in which the acrylic resin had the highest values. The veneering and infrastructure materials have influence on stress values of implant-supported dentures, except for the peri-implant bone tissue. © 2013.

  3. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique

    Directory of Open Access Journals (Sweden)

    Silvana Allegrini Kairalla

    2014-10-01

    Full Text Available INTRODUCTION: This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. METHODS: The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. RESULTS: Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25% - an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%. T-test revealed differences between males and females in the size of 12 dental arches. CONCLUSION: The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  4. Integrated MEMS/NEMS Resonant Cantilevers for Ultrasensitive Biological Detection

    Directory of Open Access Journals (Sweden)

    Xinxin Li

    2009-01-01

    Full Text Available The paper reviews the recent researches implemented in Chinese Academy of Sciences, with achievements on integrated resonant microcantilever sensors. In the resonant cantilevers, the self-sensing elements and resonance exciting elements are both top-down integrated with silicon micromachining techniques. Quite a lot of effort is focused on optimization of the resonance mode and sensing structure for improvement of sensitivity. On the other hand, to enable the micro-cantilevers specifically sensitive to bio/chemical molecules, sensing materials are developed and modified on the cantilever surface with a self-assembled monolayer (SAM based bottom-up construction and surface functionalization. To improve the selectivity of the sensors and depress environmental noise, multiple and localized surface modifications are developed. The achieved volume production capability and satisfactory detecting resolution to trace-level biological antigen of alpha-fetoprotein (AFP give the micro-cantilever sensors a great promise for rapid and high-resoluble detection.

  5. Regional cerebral perfusion for surgical correction of neonatal aortic arch obstruction.

    Science.gov (United States)

    Zhang, Hui; Cheng, Pei; Hou, Jia; Li, Lei; Liu, Hu; Liu, Ruifang; Ji, Bingyang; Luo, Yi

    2009-05-01

    One-stage repair of aortic arch obstruction and associated cardiac anomalies is a surgical challenge in infants.The purpose of the present study is to review the current outcome using regional cerebral perfusion (RCP) during a procedure correcting interrupted aortic arch (IAA) and also isolated aortic coarctation (CoA) and CoA combined with hypoplastic aortic arch (CoA-HyAA) in our center. Between January 2007 and July 2008, 24 infant patients with interrupted aortic arch (IAA) (n=3), isolated aortic coarctation (iCoA) (n=9) and aortic coarctation with hypoplastic aortic arch (CoA-HyAA) (n=12) underwent one-stage surgical correction in our hospital. End-to-end anastomosis was employed in 12 infants (IAA n=3 and iCoA n=9); for the other 12 patients with CoA-HyAA, an end-to-end extended anastomosis was used in 8 cases, end-to-side anastomosis in 2 cases, and composite heterologous pericardial patch in 2 cases. RCP with 40 mL/kg/min through the innominate artery during aortic arch reconstruction was employed for all pediatric patients. One single-dose histidine-ketoglutarate-tryptophan (HTK) solution was used for myocardial protection during CPB. Cardiopulmonary bypass time and aortic cross-clamp time were 165.6+/-32.4 min and 81.7+/-30.0 min, respectively. The mean regional cerebral perfusion time was 31.0+/-10.6 min; lowest nasopharyngeal temperature was 19.1+/-1.1 degrees C. Operative mortality rate in both groups was 8.3%. Mean follow-up was 10.5+/-4.8 months. There was no late mortality or postoperative neurologic, renal or hepatic complications. All patients are asymptomatic and are developing normally. One-stage total arch repair using the RCP technique is an excellent method that may minimize neurologic and renal complications. Our surgical strategy for arch anomaly has a low rate of residual and recurrent coarctation when performed in these infants.

  6. Bandwidth Widening of Piezoelectric Cantilever Beam Arrays by Mass-Tip Tuning for Low-Frequency Vibration Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Eduard Dechant

    2017-12-01

    Full Text Available Wireless sensor networks usually rely on internal permanent or rechargeable batteries as a power supply, causing high maintenance efforts. An alternative solution is to supply the entire system by harvesting the ambient energy, for example, by transducing ambient vibrations into electric energy by virtue of the piezoelectric effect. The purpose of this paper is to present a simple engineering approach for the bandwidth optimization of vibration energy harvesting systems comprising multiple piezoelectric cantilevers (PECs. The frequency tuning of a particular cantilever is achieved by changing the tip mass. It is shown that the bandwidth enhancement by mass tuning is limited and requires several PECs with close resonance frequencies. At a fixed frequency detuning between subsequent PECs, the achievable bandwidth shows a saturation behavior as a function of the number of cantilevers used. Since the resonance frequency of each PEC is different, the output voltages at a particular excitation frequency have different amplitudes and phases. A simple power-transfer circuit where several PECs with an individual full wave bridge rectifier are connected in parallel allows one to extract the electrical power close to the theoretical maximum excluding the diode losses. The experiments performed on two- and three-PEC arrays show reasonable agreement with simulations and demonstrate that this power-transfer circuit additionally influences the frequency dependence of the harvested electrical power.

  7. Efficiency Enhancement of a Cantilever-Based Vibration Energy Harvester

    Directory of Open Access Journals (Sweden)

    Ali E. Kubba

    2013-12-01

    Full Text Available Extracting energy from ambient vibration to power wireless sensor nodes has been an attractive area of research, particularly in the automotive monitoring field. This article reports the design, analysis and testing of a vibration energy harvesting device based on a miniature asymmetric air-spaced cantilever. The developed design offers high power density, and delivers electric power that is sufficient to support most wireless sensor nodes for structural health monitoring (SHM applications. The optimized design underwent three evolutionary steps, starting from a simple cantilever design, going through an air-spaced cantilever, and ending up with an optimized air-spaced geometry with boosted power density level. Finite Element Analysis (FEA was used as an initial tool to compare the three geometries’ stiffness (K, output open-circuit voltage (Vave, and average normal strain in the piezoelectric transducer (εave that directly affect its output voltage. Experimental tests were also carried out in order to examine the energy harvesting level in each of the three designs. The experimental results show how to boost the power output level in a thin air-spaced cantilever beam for energy within the same space envelope. The developed thin air-spaced cantilever (8.37 cm3, has a maximum power output of 2.05 mW (H = 29.29 μJ/cycle.

  8. Relevance of variations in the opposing dentition for the functionality of fixed and removable partial dentures: a systematic review.

    Science.gov (United States)

    Pommer, Bernhard; Krainhöfner, Martin; Watzek, Georg; Tepper, Gabor; Dintsios, Charalabos-Markos

    2012-01-01

    The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a "biometric quality" tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a) the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b) the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  9. Relevance of Variations in the Opposing Dentition for the Functionality of Fixed and Removable Partial Dentures: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Bernhard Pommer

    2012-01-01

    Full Text Available The aim of this systematic review was to evaluate the functionality of fixed and removable partial dentures as test interventions in relation to variations in the opposing dentition and their prosthetic restoration. The abstracts identified in the respective databases were screened independently by two investigators. RCTs and uncontrolled studies were considered, provided the patients were included consecutively and the confounding variables were adequately monitored. Seventeen papers were included. The study and publication quality was assessed using a “biometric quality” tool showing an overall poor quality. The reported outcomes, such as survival rates, were in each case obtained from a single study. Two possible trends could be deduced for the endpoint longevity: (a the first trend in favor of removable partial dentures, compared to fixed partial dentures, with a fully edentulous opposing arch fitted with a removable prosthesis; (b the second trend in favor of implant-supported partial dentures, compared to conventionally fixed partial dentures, with natural opposing dentition or with a removable partial denture in the opposing arch. No evidence could be generated as to whether, and if so how, variations in the opposing dentition have a bearing on the decision to fit a partially edentulous arch with a fixed or removable partial denture.

  10. Vibrations of beams with a variable cross-section fixed on rotational rigid disks

    Directory of Open Access Journals (Sweden)

    Slawomir Zolkiewski

    Full Text Available The work is focused on the problem of vibrating beams with a variable cross-section fixed on a rotational rigid disk. The beam is loaded by a transversal time varying force orthogonal to an axis of the beam and simultaneously parallel to the disk's plane. There are many ways of usage of the technical moveable systems composed of elements with the variable cross-sections. The main applications are used in numerous types of turbines and pumps. The paper is a kind of introduction to the dynamic analysis of above mentioned beam systems. The equations of motion of rotational beams fixed on the rigid disks were derived. After introducing the Coriolis forces and the centrifugal forces, the transportation effect in the mathematical model was considered. This particular project is the first stage research, where there were proposed certain solutions of problems connected with the linear variable cross-sections systems. The further investigation considering the nonlinear systems has been proceeding. The results, analysis and comparison will be presented in the future works.

  11. Cantilever surface stress sensors with single-crystalline silicon piezoresistors

    DEFF Research Database (Denmark)

    Rasmussen, Peter Andreas; Hansen, Ole; Boisen, Anja

    2005-01-01

    We present a cantilever with piezoresistive readout optimized for measuring the static deflection due to isotropic surface stress on the surface of the cantilever [Sens. Actuators B 79(2-3), 115 (2001)]. To our knowledge nobody has addressed the difference in physical regimes, and its influence o...

  12. Sobol method application in dimensional sensitivity analyses of different AFM cantilevers for biological particles

    Science.gov (United States)

    Korayem, M. H.; Taheri, M.; Ghahnaviyeh, S. D.

    2015-08-01

    Due to the more delicate nature of biological micro/nanoparticles, it is necessary to compute the critical force of manipulation. The modeling and simulation of reactions and nanomanipulator dynamics in a precise manipulation process require an exact modeling of cantilevers stiffness, especially the stiffness of dagger cantilevers because the previous model is not useful for this investigation. The stiffness values for V-shaped cantilevers can be obtained through several methods. One of them is the PBA method. In another approach, the cantilever is divided into two sections: a triangular head section and two slanted rectangular beams. Then, deformations along different directions are computed and used to obtain the stiffness values in different directions. The stiffness formulations of dagger cantilever are needed for this sensitivity analyses so the formulations have been driven first and then sensitivity analyses has been started. In examining the stiffness of the dagger-shaped cantilever, the micro-beam has been divided into two triangular and rectangular sections and by computing the displacements along different directions and using the existing relations, the stiffness values for dagger cantilever have been obtained. In this paper, after investigating the stiffness of common types of cantilevers, Sobol sensitivity analyses of the effects of various geometric parameters on the stiffness of these types of cantilevers have been carried out. Also, the effects of different cantilevers on the dynamic behavior of nanoparticles have been studied and the dagger-shaped cantilever has been deemed more suitable for the manipulation of biological particles.

  13. Islamic Architecture and Arch

    Directory of Open Access Journals (Sweden)

    Mohammed Mahbubur Rahman

    2015-01-01

    Full Text Available The arch, an essential architectural element since the early civilizations, permitted the construction of lighter walls and vaults, often covering a large span. Visually it was an important decorative feature that was trans-mitted from architectural decoration to other forms of art worldwide. In early Islamic period, Muslims were receiving from many civilizations, which they improved and re-introduced to bring about the Renaissance. Arches appeared in Mesopotamia, Indus, Egyptian, Babylonian, Greek and Assyrian civilizations; but the Romans applied the technique to a wide range of structures. The Muslims mastered the use and design of the arch, employed for structural and functional purposes, progressively meeting decorative and symbolic pur-poses. Islamic architecture is characterized by arches employed in all types of buildings; most common uses being in arcades. This paper discusses the process of assimilation and charts how they contributed to other civilizations.

  14. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Loganathan, Muthukumaran; Bristow, Douglas A., E-mail: dbristow@mst.edu [Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology, Rolla, Missouri 65401 (United States)

    2014-04-15

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  15. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy.

    Science.gov (United States)

    Loganathan, Muthukumaran; Bristow, Douglas A

    2014-04-01

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  16. On the calibration of rectangular atomic force microscope cantilevers modified by particle attachment and lamination

    International Nuclear Information System (INIS)

    Bowen, James; Zhang, Zhibing; Adams, Michael J; Cheneler, David; Ward, Michael C L; Walliman, Dominic; Arkless, Stuart G

    2010-01-01

    A simple but effective method for estimating the spring constant of commercially available atomic force microscope (AFM) cantilevers is presented, based on estimating the cantilever thickness from knowledge of its length, width, resonant frequency and the presence or absence of an added mass, such as a colloid probe at the cantilever apex, or a thin film of deposited material. The spring constant of the cantilever can then be estimated using standard equations for cantilever beams. The results are compared to spring constant calibration measurements performed using reference cantilevers. Additionally, the effect of the deposition of Cr and Ti thin films onto rectangular Si cantilevers is investigated

  17. Electrostatically Tunable Nanomechanical Shallow Arches

    KAUST Repository

    Kazmi, Syed N. R.

    2017-11-03

    We report an analytical and experimental study on the tunability of in-plane doubly-clamped nanomechanical arches under varied DC bias conditions at room temperature. For this purpose, silicon based shallow arches are fabricated using standard e-beam lithography and surface nanomachining of a highly conductive device layer on a silicon-on-insulator (SOI) wafer. The experimental results show good agreement with the analytical results with a maximum tunability of 108.14% for 180 nm thick arch with a transduction gap of 1 μm between the beam and the driving/sensing electrodes. The high tunability of shallow arches paves the ways for highly tunable band pass filtering applications in high frequency range.

  18. Energy harvesting from radio frequency propagation using piezoelectric cantilevers

    KAUST Repository

    Al Ahmad, Mahmoud

    2012-02-01

    This work reports an induced strain in a piezoelectric cantilever due to radio frequency signal propagation. The piezoelectric actuator is coupled to radio frequency (RF) line through a gap of 0.25 mm. When a voltage signal of 10 Vpp propagates in the line it sets an alternating current in the actuator electrodes. This flowing current drives the piezoelectric cantilever to mechanical movement, especially when the frequency of the RF signal matches the mechanical resonant frequency of the cantilever. Output voltage signals versus frequency for both mechanical vibrational and RF signal excitations have been measured using different loads.© 2011 Elsevier Ltd. All rights reserved.

  19. Conductive oxide cantilever for cryogenic nano-potentiometry

    International Nuclear Information System (INIS)

    Hiroya, Tsutomu; Inagaki, Katsuhiko; Tanda, Satoshi; Tsuneta, Taku; Yamaya, Kazuhiko

    2003-01-01

    Nanoscale electrical transport properties have attracted attentions because of new phenomena such as ballistic transport, quantized resistance, and Coulomb blockade. For measurement of nanoscale resistance, we have been developing a cryogenic atomic force microscope that can operate at 1.8 K. To use it as an electrode, we coated the cantilever with conductive oxides of TiO and indium tin oxide (ITO). We verified that TiO and ITO thin films remain conductive even at 4.2 K. Also we measured I-V characteristics of the tip-sample contact with a standard sample of NbSe 2 single crystal, and found that the conductive coats were not lost under large stresses due to the tip-sample contact. Moreover, we succeeded in obtaining a room temperature nano-potentiometry of a gold thin film with the ITO coated cantilever. In conclusion, the TiO and ITO coated cantilevers are applicable to cryogenic nano-potentiometry

  20. Cantilever piezoelectric energy harvester with multiple cavities

    International Nuclear Information System (INIS)

    S Srinivasulu Raju; M Umapathy; G Uma

    2015-01-01

    Energy harvesting employing piezoelectric materials in mechanical structures such as cantilever beams, plates, diaphragms, etc, has been an emerging area of research in recent years. The research in this area is also focused on structural tailoring to improve the harvested power from the energy harvesters. Towards this aim, this paper presents a method for improving the harvested power from a cantilever piezoelectric energy harvester by introducing multiple rectangular cavities. A generalized model for a piezoelectric energy harvester with multiple rectangular cavities at a single section and two sections is developed. A method is suggested to optimize the thickness of the cavities and the number of cavities required to generate a higher output voltage for a given cantilever beam structure. The performance of the optimized energy harvesters is evaluated analytically and through experimentation. The simulation and experimental results show that the performance of the energy harvester can be increased with multiple cavities compared to the harvester with a single cavity. (paper)

  1. Dynamic state switching in nonlinear multiferroic cantilevers

    Science.gov (United States)

    Wang, Yi; Onuta, Tiberiu-Dan; Long, Christian J.; Lofland, Samuel E.; Takeuchi, Ichiro

    2013-03-01

    We demonstrate read-write-read-erase cyclical mechanical-memory properties of all-thin-film multiferroic heterostructured Pb(Zr0.52Ti0.48) O3 / Fe0.7Ga0.3 cantilevers when a high enough voltage around the resonant frequency of the device is applied on the Pb(Zr0.52Ti0.48) O3 piezo-film. The device state switching process occurs due to the presence of a hysteresis loop in the piezo-film frequency response, which comes from the nonlinear behavior of the cantilever. The reference frequency at which the strain-mediated Fe0.7Ga0.3 based multiferroic device switches can also be tuned by applying a DC magnetic field bias that contributes to the increase of the cantilever effective stiffness. The switching dynamics is mapped in the phase space of the device measured transfer function characteristic for such high piezo-film voltage excitation, providing additional information on the dynamical stability of the devices.

  2. Transition from failing dentition to complete-arch implant rehabilitation with a staged approach: a 3-year clinical report.

    Science.gov (United States)

    Papaspyridakos, Panos; Chronopoulos, Vasilios

    2014-09-01

    The transition of patients from failing dentition to complete-arch implant rehabilitation often means that the patient is rendered edentulous and has to wear a removable complete denture for a time. Many patients find this objectionable. A staged treatment approach provides a fixed interim prosthesis for use throughout the rehabilitation process, allowing patient comfort and prosthodontic control. This clinical report describes a staged approach protocol with a new type of interim prosthesis. The prosthesis is supported by hopeless teeth and the soft tissues of the maxillary tuberosities and mandibular retromolar pads for the complete-arch implant rehabilitation of a patient with failing dentition. This protocol allows for a fixed interim prosthesis with combined tooth and mucosa or implant support during the entire rehabilitation process, thus avoiding the use of complete dentures. The implants and prostheses were functioning successfully after 3 years of clinical service. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Intraoral gothic arch tracing.

    Science.gov (United States)

    Rubel, Barry; Hill, Edward E

    2011-01-01

    In order to create optimum esthetics, function and phonetics in complete denture fabrication, it is necessary to record accurate maxillo-mandibular determinants of occlusion. This requires clinical skill to establish an accurate, verifiable and reproducible vertical dimension of occlusion (VDO) and centric relation (CR). Correct vertical relation depends upon a consideration of several factors, including muscle tone, inter-dental arch space and parallelism of the ridges. Any errors made while taking maxillo-mandibular jaw relation records will result in dentures that are uncomfortable and, possibly, unwearable. The application of a tracing mechanism such as the Gothic arch tracer (a central bearing device) is a demonstrable method of determining centric relation. Intraoral Gothic arch tracers provide the advantage of capturing VDO and CR in an easy-to-use technique for practitioners. Intraoral tracing (Gothic arch tracing) is a preferred method of obtaining consistent positions of the mandible in motion (retrusive, protrusive and lateral) at a comfortable VDO.

  4. Precast Pearl-Chain concrete arch bridges

    DEFF Research Database (Denmark)

    Halding, Philip Skov; Hertz, Kristian Dahl; Schmidt, Jacob Wittrup

    2015-01-01

    A Pearl-Chain Bridge is a closed-spandrel arch bridge consisting of a number of straight pre-fabricated so called Super-Light Deck elements put together in an arch shape by post-tensioning cables. Several Pearl-Chain arches can be positioned adjacent to each other by a crane to achieve a bridge...... of a desired width. On top of the arch is a filling material to level out the surface of the above road. The filling only transfers vertical loads to the arch. The geometry and material properties of Super-Light Decks are presented, and we refer to several fullscale tests of Pearl-Chain arches where...... the technology was used. We also study other important components and details in the Pearl-Chain Bridge concept and review the effects of different types of loads. A theoretical case study of a circular 30 m span Pearl-Chain Bridge is presented showing the influence of a number of parameters: The number of post...

  5. Combination of natural teeth and osseointegrated implants as prosthesis abutments in a posterior cantilever bridge

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2008-06-01

    Full Text Available Dental implants have been used for several decades. Patients of all ages have chosen dental implants to replace a single tooth or several teeth or to support partial or full dentures. This paper reports two cases of patients treated with dental implant as alternative to replace the missing teeth and connected with natural tooth as abutments in a fixed restoration with distal cantilever bridge. The underlining reasons that we decided to make such kind fixed prostheses are because of clinically imposible to put the implant on certain area and the patients asked for prostheses as optimum as possible, so the mastication function could return to the homeostasis condition. The benefit of these treatments are that prostheses could be made as optimum as possible with a more economic price, so the patients feel quite satisfied. The result shows that a few years after the treatments finished there is no any disadvantageous effect of connecting teeth to implants as abutments in fixed partial dentures and there is no sign of a harmful effect to the opposing teeth either.

  6. Fabrication Effects on Polysilicon-based Micro cantilever Piezo resistivity for Biological Sensing Application

    International Nuclear Information System (INIS)

    Nina Korlina Madzhi; Balkish Natra; Mastura Sidek; Khuan, L.Y.; Anuar Ahmad

    2011-01-01

    In principle, adsorption of biological molecules on a functionalized surface of a micro fabricated cantilever will cause a surface stress and consequently the cantilever bending. In this work, four different type of polysilicon-based piezo resistive micro cantilever sensors were designed to increase the sensitivity of the micro cantilevers sensor because the forces involved is very small. The design and optimization was performed by using finite element analysis to maximize the relative resistance changes of the piezo resistors as a function of the cantilever vertical displacements. The resistivity of the piezo resistivity micro cantilevers was analyzed before and after dicing process. The maximum resistance changes were systematically investigated by varying the piezo resistor length. The results show that although the thickness of piezo resistor was the same at 0.5 μm the resistance value was varied. (author)

  7. Imaging findings in the right aortic arch with mirror image branching of arch vessels: An unusual cause of dysphagia

    Directory of Open Access Journals (Sweden)

    Guneet Singh

    2015-01-01

    Full Text Available We report a case of a 72-year-old female with a right aortic arch with mirror-image branching of arch vessels presenting with dysphagia, and characteristic images on barium esophagogram, contrast-enhanced computed tomography scan, and magnetic resonance aortography. Right-sided thoracic aortic arch with mirror-image branching of the brachiocephalic vessels causing dysphagia without associated congenital cardiac anomalies is extremely uncommon. Right-sided aortic arch is a rare congenital abnormality with incidence of 0.05-0.1% in the normal population. Anomalies of great vessels are usually incidental findings, because they are asymptomatic. Right aortic arch infrequently presents with a vascular ring that can cause complete or partial obstruction of the trachea and/or esophagus. The understanding of this arch anomaly is based on Edward′s hypothesis about the double arch system during embryonic developmental.

  8. Electrothermal piezoresistive cantilever resonators for personal measurements of nanoparticles in workplace exposure

    Science.gov (United States)

    Wasisto, Hutomo Suryo; Wu, Wenze; Uhde, Erik; Waag, Andreas; Peiner, Erwin

    2015-05-01

    Low-cost and low-power piezoresistive cantilever resonators with integrated electrothermal heaters are developed to support the sensing module enhancement of the second generation of handheld cantilever-based airborne nanoparticle (NP) detector (CANTOR-2). These sensors are used for direct-reading of exposure to carbon engineered nanoparticles (ENPs) at indoor workplaces. The cantilever structures having various shapes of free ends are created using silicon bulk micromachining technologies (i.e, rectangular, hammer-head, triangular, and U-shaped cantilevers). For a complete wearable CANTOR-2, all components of the proposed detector can be grouped into two main units depending on their packaging placements (i.e., the NP sampler head and the electronics mounted in a handy-format housing). In the NP sampler head, a miniaturized electrophoretic aerosol sampler and a resonant silicon cantilever mass sensor are employed to collect the ENPs from the air stream to the cantilever surfaces and measuring their mass concentration, respectively. After calibration, the detected ENP mass concentrations of CANTOR-2 show a standard deviation from fast mobility particle sizer (FMPS, TSI 3091) of 8-14%.

  9. Footprint parameters as a measure of arch height.

    Science.gov (United States)

    Hawes, M R; Nachbauer, W; Sovak, D; Nigg, B M

    1992-01-01

    The human foot has frequently been categorized into arch height groups based upon analysis of footprint parameters. This study investigates the relationship between directly measured arch height and many of the footprint parameters that have been assumed to represent arch height. A total of 115 male subjects were measured and footprint parameters were calculated from digitized outlines. Correlation and regression analyses were used to determine the relationship between footprint measures and arch height. It may be concluded from the results that footprint parameters proposed in the literature (arch angle, footprint index, and arch index) and two further parameters suggested in this study (arch length index and truncated arch index) are invalid as a basis for prediction or categorization of arch height. The categorization of the human foot according to the footprint measures evaluated in this paper represent no more than indices and angles of the plantar surface of the foot itself.

  10. Association between breastfeeding duration, non-nutritive sucking habits and dental arch dimensions in deciduous dentition: a cross-sectional study.

    Science.gov (United States)

    Agarwal, Shiv Shankar; Nehra, Karan; Sharma, Mohit; Jayan, Balakrishna; Poonia, Anish; Bhattal, Hiteshwar

    2014-10-31

    This cross-sectional retrospective study was conducted to determine association between breastfeeding duration, non-nutritive sucking habits, dental arch transverse diameters, posterior crossbite and anterior open bite in deciduous dentition. 415 children (228 males and 187 females), 4 to 6 years old, from a mixed Indian population were clinically examined. Based on written questionnaire answered by parents, children were divided into two groups: group 1 (breastfed for anterior open bite did not differ significantly between the two groups (P = 0.865). The distribution of posterior crossbite was significantly different between the two groups (P = 0.001). OR assessment (OR = 1.852) revealed that group 1 had almost twofold higher prevalence of NNS habits than group 2. Multivariate logistic regression analysis revealed that the first group had independently fourfold increased risk of developing crossbite compared to the second group (OR = 4.3). Multivariate linear regression analysis also revealed that age and breastfeeding duration were the most significant determinants of ICD and IMD. An increased prevalence of NNS in the first group suggests that NNS is a dominant variable in the association between breastfeeding duration and reduced intra-arch transverse diameters which leads to increased prevalence of posterior crossbites as seen in our study. Mandibular inter-canine width is however unaffected due to a lowered tongue posture seen in these children.

  11. On the electromechanical modelling of a resonating nano-cantilever-based transducer

    DEFF Research Database (Denmark)

    Teva, J.; Abadal, G.; Davis, Zachary James

    2004-01-01

    deflection and the frequency response of the oscillation amplitude for different voltage polarization conditions. For the electrostatic force calculation the model takes into account the real deflection shape of the cantilever and the contribution to the cantilever-driver capacitance of the fringing field....... Both the static and dynamic predictions have been validated experimentally by measuring the deflection of the cantilever by means of an optical microscope. (C) 2004 Elsevier B.V. All rights reserved....

  12. Determination of young's modulus of PZT-influence of cantilever orientation

    NARCIS (Netherlands)

    Nazeer, H.; Woldering, L.A.; Abelmann, Leon; Elwenspoek, Michael Curt

    Calculation of the resonance frequency of cantilevers fabricated from an elastically anisotropic material requires the use of an effective Young’s modulus. In this paper a technique to determine the appropriate effective Young’s modulus for arbitrary cantilever geometries is introduced. This

  13. Electronically droplet energy harvesting using piezoelectric cantilevers

    KAUST Repository

    Al Ahmad, Mahmoud Al

    2012-01-01

    A report is presented on free falling droplet energy harvesting using piezoelectric cantilevers. The harvester incorporates a multimorph clamped-free cantilever which is composed of five layers of lead zirconate titanate piezoelectric thick films. During the impact, the droplet kinetic energy is transferred into the form of mechanical stress forcing the piezoelectric structure to vibrate. Experimental results show energy of 0.3 μJ per droplet. The scenario of moderate falling drop intensity, i.e. 230 drops per second, yields a total energy of 400 μJ. © 2012 The Institution of Engineering and Technology.

  14. New horizons in orthodontics & dentofacial orthopedics: fixed Twin Blocks & TransForce lingual appliances.

    Science.gov (United States)

    Clark, William John

    2011-01-01

    During the 20th century functional appliances evolved from night time wear to more flexible appliances for increased day time wear to full time wear with Twin Block appliances. The current trend is towards fixed functional appliances and this paper introduces the Fixed Twin Block, bonded to the teeth to eliminate problems of compliance in functional therapy. TransForce lingual appliances are pre-activated and may be used in first phase treatment for sagittal and transverse arch development. Alternatively they may be integrated with fixed appliances at any stage of treatment.

  15. A new approach for elasto-plastic finite strain analysis of cantilever ...

    Indian Academy of Sciences (India)

    A new approach for elasto-plastic finite strain analysis of cantilever beams subjected to uniform bending moment ... Curvature; deflection curve; cantilever beam; elasto-plastic analysis; tapered beam subjected to tipmoment; ... Sadhana | News.

  16. Note: A resonating reflector-based optical system for motion measurement in micro-cantilever arrays

    International Nuclear Information System (INIS)

    Sathishkumar, P.; Punyabrahma, P.; Sri Muthu Mrinalini, R.; Jayanth, G. R.

    2015-01-01

    A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array

  17. A new method for assessing the accuracy of full arch impressions in patients.

    Science.gov (United States)

    Kuhr, F; Schmidt, A; Rehmann, P; Wöstmann, B

    2016-12-01

    To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register). Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Methodical Design of Software Architecture Using an Architecture Design Assistant (ArchE)

    Science.gov (United States)

    2005-04-01

    PA 15213-3890 Methodical Design of Software Architecture Using an Architecture Design Assistant (ArchE) Felix Bachmann and Mark Klein Software...DATES COVERED 00-00-2005 to 00-00-2005 4. TITLE AND SUBTITLE Methodical Design of Software Architecture Using an Architecture Design Assistant...important for architecture design – quality requirements and constraints are most important Here’s some evidence: If the only concern is

  19. Controlling the opto-mechanics of a cantilever in an interferometer via cavity loss

    Energy Technology Data Exchange (ETDEWEB)

    Schmidsfeld, A. von, E-mail: avonschm@uos.de; Reichling, M., E-mail: reichling@uos.de [Fachbereich Physik, Universität Osnabrück, Barbarastraße 7, 49076 Osnabrück (Germany)

    2015-09-21

    In a non-contact atomic force microscope, based on interferometric cantilever displacement detection, the optical return loss of the system is tunable via the distance between the fiber end and the cantilever. We utilize this for tuning the interferometer from a predominant Michelson to a predominant Fabry-Pérot characteristics and introduce the Fabry-Pérot enhancement factor as a quantitative measure for multibeam interference in the cavity. This experimentally easily accessible and adjustable parameter provides a control of the opto-mechanical interaction between the cavity light field and the cantilever. The quantitative assessment of the light pressure acting on the cantilever oscillating in the cavity via the frequency shift allows an in-situ measurement of the cantilever stiffness with remarkable precision.

  20. Computer aided design of Langasite resonant cantilevers: analytical models and simulations

    Science.gov (United States)

    Tellier, C. R.; Leblois, T. G.; Durand, S.

    2010-05-01

    Analytical models for the piezoelectric excitation and for the wet micromachining of resonant cantilevers are proposed. Firstly, computations of metrological performances of micro-resonators allow us to select special cuts and special alignment of the cantilevers. Secondly the self-elaborated simulator TENSOSIM based on the kinematic and tensorial model furnishes etching shapes of cantilevers. As the result the number of selected cuts is reduced. Finally the simulator COMSOL® is used to evaluate the influence of final etching shape on metrological performances and especially on the resonance frequency. Changes in frequency are evaluated and deviating behaviours of structures with less favourable built-ins are tested showing that the X cut is the best cut for LGS resonant cantilevers vibrating in flexural modes (type 1 and type 2) or in torsion mode.

  1. Potential of interferometric cantilever detection and its application for SFM/AFM in liquids

    International Nuclear Information System (INIS)

    Hoogenboom, B W; Frederix, P L T M; Engel, A; Fotiadis, D; Hug, H J

    2008-01-01

    We have developed an optical cantilever deflection detector with a spot size -1/2 sensitivity over a>10 MHz bandwidth. In this work, we demonstrate its potential for detecting small-amplitude oscillations of various flexural and torsional oscillation modes of cantilevers. The high deflection sensitivity of the interferometer is particularly useful for detecting cantilever oscillations in aqueous solutions, enabling us to reach the thermal noise limit in scanning or atomic force microscopy experiments with stiff cantilevers. This has resulted in atomic-resolution images of solid-liquid interfaces and submolecular-resolution images of native membranes

  2. Highly Tunable Electrothermally Actuated Arch Resonator

    KAUST Repository

    Hajjaj, Amal Z.

    2016-12-05

    This paper demonstrates experimentally, theoretically, and numerically a wide-range tunability of electrothermally actuated MEMS arch beams. The beams are made of silicon and are intentionally fabricated with some curvature as in-plane shallow arches. Analytical results based on the Galerkin discretization of the Euler Bernoulli beam theory are generated and compared to the experimental data and results of a multi-physics finite-element model. A good agreement is found among all the results. The electrothermal voltage is applied between the anchors of the clamped-clamped MEMS arch beam, generating a current that passes through the MEMS arch beam and controls its axial stress caused by thermal expansion. When the electrothermal voltage increases, the compressive stress increases inside the arch beam. This leads to increase in its curvature, thereby increases the resonance frequencies of the structure. We show here that the first resonance frequency can increase up to twice its initial value. We show also that after some electro-thermal voltage load, the third resonance frequency starts to become more sensitive to the axial thermal stress, while the first resonance frequency becomes less sensitive. These results can be used as guidelines to utilize arches as wide-range tunable resonators.

  3. Size-dependent effective Young’s modulus of silicon nitride cantilevers

    NARCIS (Netherlands)

    Babaei Gavan, K.; Westra, H.J.R.; Van der Drift, E.W.J.M.; Venstra, W.J.; Van der Zant, H.S.J.

    2009-01-01

    The effective Young’s modulus of silicon nitride cantilevers is determined for thicknesses in the range of 20–684 nm by measuring resonance frequencies from thermal noise spectra. A significant deviation from the bulk value is observed for cantilevers thinner than 150 nm. To explain the observations

  4. Biosensors based on cantilevers.

    Science.gov (United States)

    Alvarez, Mar; Carrascosa, Laura G; Zinoviev, Kiril; Plaza, Jose A; Lechuga, Laura M

    2009-01-01

    Microcantilevers based-biosensors are a new label-free technique that allows the direct detection of biomolecular interactions in a label-less way and with great accuracy by translating the biointeraction into a nanomechanical motion. Low cost and reliable standard silicon technologies are widely used for the fabrication of cantilevers with well-controlled mechanical properties. Over the last years, the number of applications of these sensors has shown a fast growth in diverse fields, such as genomic or proteomic, because of the biosensor flexibility, the low sample consumption, and the non-pretreated samples required. In this chapter, we report a dedicated design and a fabrication process of highly sensitive microcantilever silicon sensors. We will describe as well an application of the device in the environmental field showing the immunodetection of an organic toxic pesticide as an example. The cantilever biofunctionalization process and the subsequent pesticide determination are detected in real time by monitoring the nanometer-scale bending of the microcantilever due to a differential surface stress generated between both surfaces of the device.

  5. The importance of cantilever dynamics in the interpretation of Kelvin probe force microscopy.

    Science.gov (United States)

    Satzinger, Kevin J; Brown, Keith A; Westervelt, Robert M

    2012-09-15

    A realistic interpretation of the measured contact potential difference (CPD) in Kelvin probe force microscopy (KPFM) is crucial in order to extract meaningful information about the sample. Central to this interpretation is a method to include contributions from the macroscopic cantilever arm, as well as the cone and sharp tip of a KPFM probe. Here, three models of the electrostatic interaction between a KPFM probe and a sample are tested through an electrostatic simulation and compared with experiment. In contrast with previous studies that treat the KPFM cantilever as a rigid object, we allow the cantilever to bend and rotate; accounting for cantilever bending provides the closest agreement between theory and experiment. We demonstrate that cantilever dynamics play a major role in CPD measurements and provide a simulation technique to explore this phenomenon.

  6. Evaluation of the fit of preformed nickel titanium arch wires on normal occlusion dental arches

    Directory of Open Access Journals (Sweden)

    Rakhn G. Al-Barakati

    2016-01-01

    Conclusions: Using an archwire form with the best fit to the dental arch should produce minimal changes in the dental arch form when NiTi wires are used and require less customization when stainless-steel wires are used.

  7. Cancelation of thermally induced frequency shifts in bimaterial cantilevers by nonlinear optomechanical interactions

    Energy Technology Data Exchange (ETDEWEB)

    Vy, Nguyen Duy, E-mail: nguyenduyvy@tdt.edu.vn [Theoretical Physics Research Group, Ton Duc Thang University, Ho Chi Minh City 756636 (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City 756636 (Viet Nam); Tri Dat, Le [Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh City 748355 (Viet Nam); Iida, Takuya [Department of Physical Science, Osaka Prefecture University, 1-1 Gakuen-cho, Nakaku, Sakai, Osaka 599-8531 (Japan)

    2016-08-01

    Bimaterial cantilevers have recently been used in, for example, the calorimetric analysis with picowatt resolution in microscopic space based on state-of-the-art atomic force microscopes. However, thermally induced effects usually change physical properties of the cantilevers, such as the resonance frequency, which reduce the accuracy of the measurements. Here, we propose an approach to circumvent this problem that uses an optical microcavity formed between a metallic layer coated on the back of the cantilever and one coated at the end of an optical fiber irradiating the cantilever. In addition to increasing the sensitivity, the optical rigidity of this system diminishes the thermally induced frequency shift. For a coating thickness of several tens of nanometers, the input power is 5–10 μW. These values can be evaluated from parameters derived by directly irradiating the cantilever in the absence of the microcavity. The system has the potential of using the cantilever both as a thermometer without frequency shifting and as a sensor with nanometer-controlled accuracy.

  8. MicroCantilever (MC) based nanomechanical sensor for detection of molecular interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyung [Iowa State Univ., Ames, IA (United States)

    2011-01-01

    Specific aims of this study are to investigate the mechanism governing surface stress generation associated with chemical or molecular binding on functionalized microcantilevers. Formation of affinity complexes on cantilever surfaces leads to charge redistribution, configurational change and steric hindrance between neighboring molecules resulting in surface stress change and measureable cantilever deformation. A novel interferometry technique employing two adjacent micromachined cantilevers (a sensing/reference pair) was utilized to measure the cantilever deformation. The sensing principle is that binding/reaction of specific chemical or biological species on the sensing cantilever transduces to mechanical deformation. The differential bending of the sensing cantilever respect to the reference cantilever ensures that measured response is insensitive to environmental disturbances. As a proof of principle for the measurement technique, surface stress changes associated with: self-assembly of alkanethiol, hybridization of ssDNA, and the formation of cocaine-aptamer complexes were measured. Dissociation constant (Kd) for each molecular reaction was utilized to estimate the surface coverage of affinity complexes. In the cases of DNA hybridization and cocaine-aptamer binding, measured surface stress was found to be dependent on the surface coverage of the affinity complexes. In order to achieve a better sensitivity for DNA hybridization, immobilization of receptor molecules was modified to enhance the deformation of underlying surface. Single-stranded DNA (ssDNA) strands with thiol-modification on both 3-foot and 5-foot ends were immobilized on the gold surface such that both ends are attached to the gold surface. Immobilization condition was controlled to obtain similar receptor density as single-thiolated DNA strands. Hybridization of double-thiolated DNA strands leads to an almost two orders of magnitude increase in cantilever deformation. In both DNA

  9. Electrothermally Tunable Arch Resonator

    KAUST Repository

    Hajjaj, Amal Z.

    2017-03-18

    This paper demonstrates experimentally, theoretically, and numerically a wide-range tunability of electrothermally actuated microelectromechanical arch beams. The beams are made of silicon and are intentionally fabricated with some curvature as in-plane shallow arches. An electrothermal voltage is applied between the anchors of the beam generating a current that controls the axial stress caused by thermal expansion. When the electrothermal voltage increases, the compressive stress increases inside the arch beam. This leads to an increase in its curvature, thereby increasing its resonance frequencies. We show here that the first resonance frequency can increase monotonically up to twice its initial value. We show also that after some electrothermal voltage load, the third resonance frequency starts to become more sensitive to the axial thermal stress, while the first resonance frequency becomes less sensitive. These results can be used as guidelines to utilize arches as wide-range tunable resonators. Analytical results based on the nonlinear Euler Bernoulli beam theory are generated and compared with the experimental data and the results of a multi-physics finite-element model. A good agreement is found among all the results. [2016-0291

  10. Investigations on antibody binding to a micro-cantilever coated with a BAM pesticide residue

    Directory of Open Access Journals (Sweden)

    Aamand Jens

    2011-01-01

    Full Text Available Abstract The attachment of an antibody to an antigen-coated cantilever has been investigated by repeated experiments, using a cantilever-based detection system by Cantion A/S. The stress induced by the binding of a pesticide residue BAM (2,6 dichlorobenzamide immobilized on a cantilever surface to anti-BAM antibody is measured using the CantiLab4© system from Cantion A/S with four gold-coated cantilevers and piezo resistive readout. The detection mechanism is in principle label-free, but fluorescent-marked antibodies have been used to subsequently verify the binding on the cantilever surface. The bending and increase in mass of each cantilever has also been investigated using a light interferometer and a Doppler Vibrometer. The system has been analyzed during repeated measurements to investigate whether the CantiLab4© system is a suited platform for a pesticide assay system.

  11. Standardizing foot-type classification using arch index values.

    Science.gov (United States)

    Wong, Christopher Kevin; Weil, Rich; de Boer, Emily

    2012-01-01

    The lack of a reliable classification standard for foot type makes drawing conclusions from existing research and clinical decisions difficult, since different foot types may move and respond to treatment differently. The purpose of this study was to determine interrater agreement for foot-type classification based on photo-box-derived arch index values. For this correlational study with two raters, a sample of 11 healthy volunteers with normal to obese body mass indices was recruited from both a community weight-loss programme and a programme in physical therapy. Arch index was calculated using AutoCAD software from footprint photographs obtained via mirrored photo-box. Classification as high-arched, normal, or low-arched foot type was based on arch index values. Reliability of the arch index was determined with intra-class correlations; agreement on foot-type classification was determined using quadratic weighted kappa (κw). Average arch index was 0.215 for one tester and 0.219 for the second tester, with an overall range of 0.017 to 0.370. Both testers classified 6 feet as low-arched, 9 feet as normal, and 7 feet as high-arched. Interrater reliability for the arch index was ICC=0.90; interrater agreement for foot-type classification was κw=0.923. Classification of foot type based on arch index values derived from plantar footprint photographs obtained via mirrored photo-box showed excellent reliability in people with varying BMI. Foot-type classification may help clinicians and researchers subdivide sample populations to better differentiate mobility, gait, or treatment effects among foot types.

  12. Standardizing Foot-Type Classification Using Arch Index Values

    Science.gov (United States)

    Weil, Rich; de Boer, Emily

    2012-01-01

    ABSTRACT Purpose: The lack of a reliable classification standard for foot type makes drawing conclusions from existing research and clinical decisions difficult, since different foot types may move and respond to treatment differently. The purpose of this study was to determine interrater agreement for foot-type classification based on photo-box-derived arch index values. Method: For this correlational study with two raters, a sample of 11 healthy volunteers with normal to obese body mass indices was recruited from both a community weight-loss programme and a programme in physical therapy. Arch index was calculated using AutoCAD software from footprint photographs obtained via mirrored photo-box. Classification as high-arched, normal, or low-arched foot type was based on arch index values. Reliability of the arch index was determined with intra-class correlations; agreement on foot-type classification was determined using quadratic weighted kappa (κw). Results: Average arch index was 0.215 for one tester and 0.219 for the second tester, with an overall range of 0.017 to 0.370. Both testers classified 6 feet as low-arched, 9 feet as normal, and 7 feet as high-arched. Interrater reliability for the arch index was ICC=0.90; interrater agreement for foot-type classification was κw=0.923. Conclusions: Classification of foot type based on arch index values derived from plantar footprint photographs obtained via mirrored photo-box showed excellent reliability in people with varying BMI. Foot-type classification may help clinicians and researchers subdivide sample populations to better differentiate mobility, gait, or treatment effects among foot types. PMID:23729964

  13. Feedback cooling of cantilever motion using a quantum point contact transducer

    International Nuclear Information System (INIS)

    Montinaro, M.; Mehlin, A.; Solanki, H. S.; Peddibhotla, P.; Poggio, M.; Mack, S.; Awschalom, D. D.

    2012-01-01

    We use a quantum point contact (QPC) as a displacement transducer to measure and control the low-temperature thermal motion of a nearby micromechanical cantilever. The QPC is included in an active feedback loop designed to cool the cantilever's fundamental mechanical mode, achieving a squashing of the QPC noise at high gain. The minimum achieved effective mode temperature of 0.2 K and the displacement resolution of 10 -11 m/√(Hz) are limited by the performance of the QPC as a one-dimensional conductor and by the cantilever-QPC capacitive coupling.

  14. Improved Noninterferometric Test of Collapse Models Using Ultracold Cantilevers

    Science.gov (United States)

    Vinante, A.; Mezzena, R.; Falferi, P.; Carlesso, M.; Bassi, A.

    2017-09-01

    Spontaneous collapse models predict that a weak force noise acts on any mechanical system, as a consequence of the collapse of the wave function. Significant upper limits on the collapse rate have been recently inferred from precision mechanical experiments, such as ultracold cantilevers and the space mission LISA Pathfinder. Here, we report new results from an experiment based on a high-Q cantilever cooled to millikelvin temperatures, which is potentially able to improve the current bounds on the continuous spontaneous localization (CSL) model by 1 order of magnitude. High accuracy measurements of the cantilever thermal fluctuations reveal a nonthermal force noise of unknown origin. This excess noise is compatible with the CSL heating predicted by Adler. Several physical mechanisms able to explain the observed noise have been ruled out.

  15. Potential of interferometric cantilever detection and its application for SFM/AFM in liquids

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, B W [London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, 17-19 Gordon Street, London WC1H 0AH (United Kingdom); Frederix, P L T M; Engel, A [M E Mueller Institute, Biozentrum, University of Basel, Klingelbergstrasse 70, 4056 Basel (Switzerland); Fotiadis, D [Institute of Biochemistry and Molecular Medicine, University of Berne, Buehlstrasse 28, 3012 Berne (Switzerland); Hug, H J [Swiss Federal Laboratories for Materials Testing and Research, EMPA, Ueberlandstrasse 129, 8600 Duebendorf (Switzerland)], E-mail: b.hoogenboom@ucl.ac.uk

    2008-09-24

    We have developed an optical cantilever deflection detector with a spot size <3 {mu}m and fm Hz{sup -1/2} sensitivity over a>10 MHz bandwidth. In this work, we demonstrate its potential for detecting small-amplitude oscillations of various flexural and torsional oscillation modes of cantilevers. The high deflection sensitivity of the interferometer is particularly useful for detecting cantilever oscillations in aqueous solutions, enabling us to reach the thermal noise limit in scanning or atomic force microscopy experiments with stiff cantilevers. This has resulted in atomic-resolution images of solid-liquid interfaces and submolecular-resolution images of native membranes.

  16. Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies

    Science.gov (United States)

    Kohli, Shivani; Kalsi, Rupali

    2016-01-01

    Introduction Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. Aim This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. Materials and Methods The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. Results The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. Conclusion The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials. PMID:27437342

  17. Assembly and lifting of Pearl-Chain arches

    DEFF Research Database (Denmark)

    Halding, Philip Skov; Hertz, Kristian Dahl; Viebæk, N.E.

    2015-01-01

    Pearl-Chain arches were invented at the Technical University of Denmark in cooporation with the company Abeo A/S. The system uses specially designed, pre-fabricated concrete elements that are post-tensioned together into an arch shape, which is then lifted into place. The arches can be used both ...

  18. Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markers

    International Nuclear Information System (INIS)

    Slattery, Ashley D; Blanch, Adam J; Quinton, Jamie S; Gibson, Christopher T

    2013-01-01

    Static methods to determine the spring constant of AFM cantilevers have been widely used in the scientific community since the importance of such calibration techniques was established nearly 20 years ago. The most commonly used static techniques involve loading a trial cantilever with a known force by pressing it against a pre-calibrated standard or reference cantilever. These reference cantilever methods have a number of sources of uncertainty, which include the uncertainty in the measured spring constant of the standard cantilever, the exact position of the loading point on the reference cantilever and how closely the spring constant of the trial and reference cantilever match. We present a technique that enables users to minimize these uncertainties by creating spatial markers on reference cantilevers using a focused ion beam (FIB). We demonstrate that by combining FIB spatial markers with an inverted reference cantilever method, AFM cantilevers can be accurately calibrated without the tip of the test cantilever contacting a surface. This work also demonstrates that for V-shaped cantilevers it is possible to determine the precise loading position by AFM imaging the section of the cantilever where the two arms join. Removing tip-to-surface contact in both the reference cantilever method and sensitivity calibration is a significant improvement, since this is an important consideration for AFM users that require the imaging tip to remain in pristine condition before commencing measurements. Uncertainties of between 5 and 10% are routinely achievable with these methods. (paper)

  19. Cross-pinning: the philosophy of retrievability applied practically to fixed, implant-supported prostheses.

    Science.gov (United States)

    Gervais, M J; Hatzipanagiotis, P; Wilson, P R

    2008-03-01

    Biologic and technical complications are widely reported in the dental literature and often compromise the functional and/or aesthetic features of fixed, implant-supported prostheses. Managing complications without damaging or destroying a restoration is an obvious advantage of implant-based dentistry where the option of prosthetic retrievability is almost always available. The technique of cross-pinning uses a transverse screw to secure a prosthesis to a milled implant abutment, allowing prosthetic retrievability irrespective of dental implant alignment. This study presents guidelines for cross-pinning implant-supported prostheses based on resistance form, screw mechanics and natural tooth contours. The technical aspects of cross-pinning are also discussed using examples from four implant systems.

  20. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Ashley D.; Blanch, Adam J.; Quinton, Jamie S.; Gibson, Christopher T., E-mail: christopher.gibson@flinders.edu.au

    2013-08-15

    Considerable attention has been given to the calibration of AFM cantilever spring constants in the last 20 years. Techniques that do not require tip-sample contact are considered advantageous since the imaging tip is not at risk of being damaged. Far less attention has been directed toward measuring the cantilever deflection or sensitivity, despite the fact that the primary means of determining this factor relies on the AFM tip being pressed against a hard surface, such as silicon or sapphire; which has the potential to significantly damage the tip. A recent method developed by Tourek et al. in 2010 involves deflecting the AFM cantilever a known distance from the imaging tip by pressing the cantilever against a sharpened tungsten wire. In this work a similar yet more precise method is described, whereby the deflection of the cantilever is achieved using an AFM probe with a spring constant much larger than the test cantilever, essentially a rigid cantilever. The exact position of loading on the test cantilever was determined by reverse AFM imaging small spatial markers that are milled into the test cantilever using a focussed ion beam. For V shaped cantilevers it is possible to reverse image the arm intersection in order to determine the exact loading point without necessarily requiring FIB milled spatial markers, albeit at the potential cost of additional uncertainty. The technique is applied to tip-less, beam shaped and V shaped cantilevers and compared to the hard surface contact technique with very good agreement (on average less than 5% difference). While the agreement with the hard surface contact technique was very good the error on the technique is dependent upon the assumptions inherent in the method, such as cantilever shape, loading point distance and ratio of test to rigid cantilever spring constants. The average error ranged between 2 to 5% for the majority of test cantilevers studied. The sensitivity derived with this technique can then be used to

  1. Research on fiber-optic cantilever-enhanced photoacoustic spectroscopy for trace gas detection

    Science.gov (United States)

    Chen, Ke; Zhou, Xinlei; Gong, Zhenfeng; Yu, Shaochen; Qu, Chao; Guo, Min; Yu, Qingxu

    2018-01-01

    We demonstrate a new scheme of cantilever-enhanced photoacoustic spectroscopy, combining a sensitivity-improved fiber-optic cantilever acoustic sensor with a tunable high-power fiber laser, for trace gas detection. The Fabry-Perot interferometer based cantilever acoustic sensor has advantages such as high sensitivity, small size, easy to install and immune to electromagnetic. Tunable erbium-doped fiber ring laser with an erbium-doped fiber amplifier is used as the light source for acoustic excitation. In order to improve the sensitivity for photoacoustic signal detection, a first-order longitudinal resonant photoacoustic cell with the resonant frequency of 1624 Hz and a large size cantilever with the first resonant frequency of 1687 Hz are designed. The size of the cantilever is 2.1 mm×1 mm, and the thickness is 10 μm. With the wavelength modulation spectrum and second-harmonic detection methods, trace ammonia (NH3) has been measured. The gas detection limits (signal-to-noise ratio = 1) near the wavelength of 1522.5 nm is achieved to be 3 ppb.

  2. MEMS-based silicon cantilevers with integrated electrothermal heaters for airborne ultrafine particle sensing

    Science.gov (United States)

    Wasisto, Hutomo Suryo; Merzsch, Stephan; Waag, Andreas; Peiner, Erwin

    2013-05-01

    The development of low-cost and low-power MEMS-based cantilever sensors for possible application in hand-held airborne ultrafine particle monitors is described in this work. The proposed resonant sensors are realized by silicon bulk micromachining technology with electrothermal excitation, piezoresistive frequency readout, and electrostatic particle collection elements integrated and constructed in the same sensor fabrication process step of boron diffusion. Built-in heating resistor and full Wheatstone bridge are set close to the cantilever clamp end for effective excitation and sensing, respectively, of beam deflection. Meanwhile, the particle collection electrode is located at the cantilever free end. A 300 μm-thick, phosphorus-doped silicon bulk wafer is used instead of silicon-on-insulator (SOI) as the starting material for the sensors to reduce the fabrication costs. To etch and release the cantilevers from the substrate, inductively coupled plasma (ICP) cryogenic dry etching is utilized. By controlling the etching parameters (e.g., temperature, oxygen content, and duration), cantilever structures with thicknesses down to 10 - 20 μm are yielded. In the sensor characterization, the heating resistor is heated and generating thermal waves which induce thermal expansion and further cause mechanical bending strain in the out-of-plane direction. A resonant frequency of 114.08 +/- 0.04 kHz and a quality factor of 1302 +/- 267 are measured in air for a fabricated rectangular cantilever (500x100x13.5 μm3). Owing to its low power consumption of a few milliwatts, this electrothermal cantilever is suitable for replacing the current external piezoelectric stack actuator in the next generation of the miniaturized cantilever-based nanoparticle detector (CANTOR).

  3. Use of self-sensing piezoresistive Si cantilever sensor for determining carbon nanoparticle mass

    Science.gov (United States)

    Wasisto, H. S.; Merzsch, S.; Stranz, A.; Waag, A.; Uhde, E.; Kirsch, I.; Salthammer, T.; Peiner, E.

    2011-06-01

    A silicon cantilever with slender geometry based Micro Electro Mechanical System (MEMS) for nanoparticles mass detection is presented in this work. The cantilever is actuated using a piezoactuator at the bottom end of the cantilever supporting frame. The oscillation of the microcantilever is detected by a self-sensing method utilizing an integrated full Wheatstone bridge as a piezoresistive strain gauge for signal read out. Fabricated piezoresistive cantilevers of 1.5 mm long, 30 μm wide and 25 μm thick have been employed. This self-sensing cantilever is used due to its simplicity, portability, high-sensitivity and low-cost batch microfabrication. In order to investigate air pollution sampling, a nanoparticles collection test of the piezoresistive cantilever sensor is performed in a sealed glass chamber with a stable carbon aerosol inside. The function principle of cantilever sensor is based on detecting the resonance frequency shift that is directly induced by an additional carbon nanoparticles mass deposited on it. The deposition of particles is enhanced by an electrostatic field. The frequency measurement is performed off-line under normal atmospheric conditions, before and after carbon nanoparticles sampling. The calculated equivalent mass-induced resonance frequency shift of the experiment is measured to be 11.78 +/- 0.01 ng and a mass sensitivity of 8.33 Hz/ng is obtained. The proposed sensor exhibits an effective mass of 2.63 μg, a resonance frequency of 43.92 kHz, and a quality factor of 1230.68 +/- 78.67. These results and analysis indicate that the proposed self-sensing piezoresistive silicon cantilever can offer the necessary potential for a mobile nanoparticles monitor.

  4. A piezoresistive cantilever for lateral force detection fabricated by a monolithic post-CMOS process

    International Nuclear Information System (INIS)

    Ji Xu; Li Zhihong; Li Juan; Wang Yangyuan; Xi Jianzhong

    2008-01-01

    This paper presents a post-CMOS process to monolithically integrate a piezoresistive cantilever for lateral force detection and signal processing circuitry. The fabrication process includes a standard CMOS process and one more lithography step to micromachine the cantilever structure in the post-CMOS process. The piezoresistors are doped in the CMOS process but defined in the post-CMOS micromachining process without any extra process required. A partially split cantilever configuration is developed for the lateral force detection. The piezoresistors are self-aligned to the split cantilever, and therefore the width of the beam is only limited by lithography. Consequently, this kind of cantilever potentially has a high resolution. The preliminary experimental results show expected performances of the fabricated piezoresistors and electronic circuits

  5. Modified cantilevers to probe unambiguously out-of-plane piezoresponse

    Science.gov (United States)

    Alyabyeva, Natalia; Ouvrard, Aimeric; Lindfors-Vrejoiu, Ionela; Kolomiytsev, Alexey; Solodovnik, Maxim; Ageev, Oleg; McGrouther, Damien

    2018-06-01

    We demonstrate and investigate the coupling of contributions from both in-plane (IP) polarization and out-of-plane (OP) components in BiFeO3 (BFO) thin-film polarization probed by piezoresponse force microscopy (PFM). Such coupling leads to image artifacts which prevent the correct determination of OP polarization vector directions and the corresponding piezoelectric coefficient d33. Using material strength theory with a one-dimensional modeling of the cantilever oscillation amplitude under electrostatic and elastic forces as a function of the tip length, we have evidenced the impact of IP piezoresponse to the OP signal for tip length longer than 4 μm. The IP polarization vector induces a significant longitudinal bending of the cantilever, due to the small spring constant of long tips, which provokes a normal deviation superimposed to the OP piezoresponse. These artifacts can be reduced by increasing the longitudinal spring constant of the cantilever by shortening the tip length. Standard cantilevers with 15-μm-long tips were modified to reach the desired tip length, using focused ion-beam techniques and tested using PFM on the same BFO thin film. Tip length shortening has strongly reduced IP artifacts as expected, while the impact of nonlocal electrostatic forces, becoming predominant for tips shorter than 1 μm, has led to a non-negligible deflection offset. For shorter tips, a strong electric field from a cantilever beam can induce polarization switching as observed for a 0.5-μm-long tip. Tip length ranging from 1 to 4 μm allowed minimizing both artifacts to probe unambiguously OP piezoresponse and quantify the d33 piezoelectric coefficient.

  6. Piezoresistive Cantilever Performance-Part I: Analytical Model for Sensitivity.

    Science.gov (United States)

    Park, Sung-Jin; Doll, Joseph C; Pruitt, Beth L

    2010-02-01

    An accurate analytical model for the change in resistance of a piezoresistor is necessary for the design of silicon piezoresistive transducers. Ion implantation requires a high-temperature oxidation or annealing process to activate the dopant atoms, and this treatment results in a distorted dopant profile due to diffusion. Existing analytical models do not account for the concentration dependence of piezoresistance and are not accurate for nonuniform dopant profiles. We extend previous analytical work by introducing two nondimensional factors, namely, the efficiency and geometry factors. A practical benefit of this efficiency factor is that it separates the process parameters from the design parameters; thus, designers may address requirements for cantilever geometry and fabrication process independently. To facilitate the design process, we provide a lookup table for the efficiency factor over an extensive range of process conditions. The model was validated by comparing simulation results with the experimentally determined sensitivities of piezoresistive cantilevers. We performed 9200 TSUPREM4 simulations and fabricated 50 devices from six unique process flows; we systematically explored the design space relating process parameters and cantilever sensitivity. Our treatment focuses on piezoresistive cantilevers, but the analytical sensitivity model is extensible to other piezoresistive transducers such as membrane pressure sensors.

  7. Piezoresistive Cantilever Performance—Part I: Analytical Model for Sensitivity

    Science.gov (United States)

    Park, Sung-Jin; Doll, Joseph C.; Pruitt, Beth L.

    2010-01-01

    An accurate analytical model for the change in resistance of a piezoresistor is necessary for the design of silicon piezoresistive transducers. Ion implantation requires a high-temperature oxidation or annealing process to activate the dopant atoms, and this treatment results in a distorted dopant profile due to diffusion. Existing analytical models do not account for the concentration dependence of piezoresistance and are not accurate for nonuniform dopant profiles. We extend previous analytical work by introducing two nondimensional factors, namely, the efficiency and geometry factors. A practical benefit of this efficiency factor is that it separates the process parameters from the design parameters; thus, designers may address requirements for cantilever geometry and fabrication process independently. To facilitate the design process, we provide a lookup table for the efficiency factor over an extensive range of process conditions. The model was validated by comparing simulation results with the experimentally determined sensitivities of piezoresistive cantilevers. We performed 9200 TSUPREM4 simulations and fabricated 50 devices from six unique process flows; we systematically explored the design space relating process parameters and cantilever sensitivity. Our treatment focuses on piezoresistive cantilevers, but the analytical sensitivity model is extensible to other piezoresistive transducers such as membrane pressure sensors. PMID:20336183

  8. Highly sensitive polymer-based cantilever-sensors for DNA detection

    International Nuclear Information System (INIS)

    Calleja, M.; Nordstroem, M.; Alvarez, M.; Tamayo, J.; Lechuga, L.M.; Boisen, A.

    2005-01-01

    We present a technology for the fabrication of cantilever arrays aimed to develop an integrated biosensor microsystem. The fabrication process is based on spin coating of the photosensitive polymer and near-ultraviolet exposure. Arrays of up to 33 microcantilevers are fabricated in the novel polymer material SU-8. The low Young's modulus of the polymer, 40 times lower than that of silicon, enables to improve the sensitivity of the sensor device for target detection. The mechanical properties of SU-8 cantilevers, such as spring constant, resonant frequency and quality factor are characterized as a function of the dimensions and the medium. The devices have been tested for measurement of the adsorption of single stranded DNA and subsequent interstitial adsorption of lateral spacer molecules. We demonstrate that sensitivity is enhanced by a factor of six compared to that of commercial silicon nitride cantilevers

  9. Accurate Calibration and Uncertainty Estimation of the Normal Spring Constant of Various AFM Cantilevers

    Directory of Open Access Journals (Sweden)

    Yunpeng Song

    2015-03-01

    Full Text Available Measurement of force on a micro- or nano-Newton scale is important when exploring the mechanical properties of materials in the biophysics and nanomechanical fields. The atomic force microscope (AFM is widely used in microforce measurement. The cantilever probe works as an AFM force sensor, and the spring constant of the cantilever is of great significance to the accuracy of the measurement results. This paper presents a normal spring constant calibration method with the combined use of an electromagnetic balance and a homemade AFM head. When the cantilever presses the balance, its deflection is detected through an optical lever integrated in the AFM head. Meanwhile, the corresponding bending force is recorded by the balance. Then the spring constant can be simply calculated using Hooke’s law. During the calibration, a feedback loop is applied to control the deflection of the cantilever. Errors that may affect the stability of the cantilever could be compensated rapidly. Five types of commercial cantilevers with different shapes, stiffness, and operating modes were chosen to evaluate the performance of our system. Based on the uncertainty analysis, the expanded relative standard uncertainties of the normal spring constant of most measured cantilevers are believed to be better than 2%.

  10. A new approach to integrate PLZT thin films with micro-cantilevers

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana; Volume 34; Issue 4. A new approach to integrate PLZT thin films with micro-cantilevers ... Different types of cantilever beams incorporating PLZT films have been successfully fabricated using 'lift-off' process and bulk micromachining technology. The proposed process can be advantageously ...

  11. A novel fabrication technique for free-hanging homogeneous polymeric cantilever waveguides

    DEFF Research Database (Denmark)

    Nordström, M.; Calleja, M.; Hübner, Jörg

    2008-01-01

    We present a novel bonding technique developed for the fabrication of a cantilever-based biosensing system with integrated optical read-out. The read-out mechanism is based on single-mode waveguides fabricated monolithically in SU-8. For optimal operation of the read-out mode, the cantilever...

  12. Semi-parametric estimation for ARCH models

    Directory of Open Access Journals (Sweden)

    Raed Alzghool

    2018-03-01

    Full Text Available In this paper, we conduct semi-parametric estimation for autoregressive conditional heteroscedasticity (ARCH model with Quasi likelihood (QL and Asymptotic Quasi-likelihood (AQL estimation methods. The QL approach relaxes the distributional assumptions of ARCH processes. The AQL technique is obtained from the QL method when the process conditional variance is unknown. We present an application of the methods to a daily exchange rate series. Keywords: ARCH model, Quasi likelihood (QL, Asymptotic Quasi-likelihood (AQL, Martingale difference, Kernel estimator

  13. Performance of Arch-Style Road Crossing Structures from Relative Movement Rates of Large Mammals

    Directory of Open Access Journals (Sweden)

    A. Z. Andis

    2017-10-01

    Full Text Available In recent decades, an increasing number of highway construction and reconstruction projects have included mitigation measures aimed at reducing wildlife-vehicle collisions and maintaining habitat connectivity for wildlife. The most effective and robust measures include wildlife fences combined with wildlife underpasses and overpasses. The 39 wildlife crossing structures included along a 90 km stretch of US Highway 93 on the Flathead Indian Reservation in western Montana represent one of the most extensive of such projects. We measured movements of large mammal species at 15 elliptical arch-style wildlife underpasses and adjacent habitat between April and November 2015. We investigated if the movements of large mammals through the underpasses were similar to large mammal movements in the adjacent habitat. Across all structures, large mammals (all species combined were more likely to move through the structures than pass at a random location in the surrounding habitat. At the species level, white-tailed deer (Odocoileus virginianus and mule deer (O. hemionus used the underpasses significantly more than could be expected based on their movement through the surrounding habitat. However, carnivorous species such as, black bear (Ursus americanus and coyote (Canis latrans moved through the underpasses in similar numbers compared to the surrounding habitat.

  14. Fiber-top cantilever: a new generation of micromachined sensors for multipurpose applications

    NARCIS (Netherlands)

    Iannuzzi, D.; Deladi, S.; Schreuders, H.; Slaman, M.; Rector, J.H.; Elwenspoek, Michael Curt

    2006-01-01

    Fiber-top cantilevers are new monolithic devices obtained by carving a cantilever out of the edge of a single-mode optical fiber. Here we report evidences of their potential impact as sensing devices for multipurpose applications.

  15. Design and Fabrication of Piezoresistive Based Encapsulated Poly-Si Cantilevers for Bio/chemical Sensing

    Science.gov (United States)

    Krishna, N. P. Vamsi; Murthy, T. R. Srinivasa; Reddy, K. Jayaprakash; Sangeeth, K.; Hegde, G. M.

    Cantilever-based sensing is a growing research field not only within micro regime but also in nano technology. The technology offers a method for rapid, on-line and in-situ monitoring of specific bio/chemical substances by detecting the nanomechanical responses of a cantilever sensor. Cantilever with piezoresistive based detection scheme is more attractive because of its electronics compatibility. Majority of commercially available micromachined piezoresistive sensors are bulk micromachined devices and are fabricated using single crystal silicon wafers. As substrate properties are not important in surface micromachining, the expensive silicon wafers can be replaced by cheaper substrates, such as poly-silicon, glass or plastic. Here we have designed SU-8 based bio/chemical compatible micro electro mechanical device that includes an encapsulated polysilicon piezoresistor for bio/chemical sensing. In this paper we report the design, fabrication and analysis of the encapsulated poly-Si cantilevers. Design and theoretical analysis are carried out using Finite Element Analysis software. For fabrication of poly-silicon piezoresistive cantilevers we followed the surface micromachining process steps. Preliminary characterization of the cantilevers is presented.

  16. Nonlinear Dynamics of Electrostatically Actuated MEMS Arches

    KAUST Repository

    Al Hennawi, Qais M.

    2015-05-01

    In this thesis, we present theoretical and experimental investigation into the nonlinear statics and dynamics of clamped-clamped in-plane MEMS arches when excited by an electrostatic force. Theoretically, we first solve the equation of motion using a multi- mode Galarkin Reduced Order Model (ROM). We investigate the static response of the arch experimentally where we show several jumps due to the snap-through instability. Experimentally, a case study of in-plane silicon micromachined arch is studied and its mechanical behavior is measured using optical techniques. We develop an algorithm to extract various parameters that are needed to model the arch, such as the induced axial force, the modulus of elasticity, and the initially induced initial rise. After that, we excite the arch by a DC electrostatic force superimposed to an AC harmonic load. A softening spring behavior is observed when the excitation is close to the first resonance frequency due to the quadratic nonlinearity coming from the arch geometry and the electrostatic force. Also, a hardening spring behavior is observed when the excitation is close to the third (second symmetric) resonance frequency due to the cubic nonlinearity coming from mid-plane stretching. Then, we excite the arch by an electric load of two AC frequency components, where we report a combination resonance of the summed type. Agreement is reported among the theoretical and experimental work.

  17. A study on occlusal stability in shortened dental arches.

    Science.gov (United States)

    Sarita, Paulo T N; Kreulen, Cees M; Witter, Dick J; van't Hof, Martin; Creugers, Nico H J

    2003-01-01

    The aim of this study was to verify the hypothesis that shortened dental arches constitute a risk to occlusal stability. Using cluster samples, 725 subjects with shortened dental arches comprising intact anterior regions and zero to eight occluding pairs of posterior teeth and 125 subjects with complete dental arches were selected. Subjects with shortened dental arches were classified into eight categories according to arch length and symmetry. Parameters for occlusal stability were interdental spacing, occlusal tooth wear, occlusal contact of incisors in intercuspal position, and vertical and horizontal overlap. Additionally, tooth mobility and overeruption of unopposed teeth were assessed. Influence of independent variables (dental arch category, age, gender, and residence) on the parameters for occlusal stability was assessed by one-way ANOVA and Tukey's multiple range tests. Extreme shortened dental arches (zero to two pairs of occluding premolars) had significantly more interdental spacing, occlusal contact of incisors, and vertical overlap compared to complete dental arches. Occlusal wear and prevalence of mobile teeth were highest in these categories. The category with three to four occluding premolars had significantly more interdental spacing and, for the older age group, more anterior teeth in occlusal contact compared to complete dental arches. Age was consistently associated with increased changes in occlusal integrity. Signs of increased risk to occlusal stability seemed to occur in extreme shortened dental arches, whereas no such evidence was found for intermediate categories of shortened dental arches.

  18. Finite-Element Simulation of Cantilever Vibrations in Atomic Force Acoustic Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, F J Espinoza [Centro de Investigacion y Estudios Avanzados del IPN. Unidad Queretaro, Apdo. Postal 1-798, 76001 Queretaro, Qro. (Mexico); Scholz, T [Hamburg University of Technology, Institute of Advanced Ceramics, Denickestrasse 15, D-21073 Hamburg (Germany); Schneider, G A [Hamburg University of Technology, Institute of Advanced Ceramics, Denickestrasse 15, D-21073 Hamburg (Germany); Munoz-Saldana, J [Centro de Investigacion y Estudios Avanzados del IPN. Unidad Queretaro, Apdo. Postal 1-798, 76001 Queretaro, Qro. (Mexico); Rabe, U [Fraunhofer Institute for Non-Destructive Testing (IZFP), Bldg. E3.1, University, D-66123 Saarbruecken (Germany); Arnold, W [Fraunhofer Institute for Non-Destructive Testing (IZFP), Bldg. E3.1, University, D-66123 Saarbruecken (Germany)

    2007-03-15

    Atomic Force Acoustic Microscopy has been proven to be a powerful technique for materials characterization with nanoscale lateral resolution. This technique allows one to obtain images of elastic properties of materials. By means of spectroscopic measurements of the tip-sample contact-resonance frequencies, it is possible to obtain quantitative values of the mechanical stiffness of the sample surface. For quantitative analysis a reliable relation between the spectroscopic data and the contact stiffness is required based on a correct geometrical model of the cantilever vibrations. This model must be precise enough for predicting the resonance frequencies of the tip-sample interaction when excited over a wide range of frequencies. Analytical models have served as a good reference for understanding the vibrational behavior of the AFM cantilever. They have certain limits, however, for reproducing the tip-sample contact-resonances due to the cantilever geometries used. For obtaining the local elastic modulus of samples, it is necessary to know the tip-sample contact area which is usually obtained by a calibration procedure with a reference sample. In this work we show that finiteelement modeling may be used to replace the analytical inversion procedure for AFAM data. First, the three first bending modes of cantilever resonances were used for finding the geometrical dimension of the cantilever employed. Then the normal and in-plane stiffness of the sample were obtained for each measurement on the surface to be measured. A calibration was needed to obtain the tip position of the cantilever by making measurements on a sample with known surface elasticity, here crystalline silicon. The method developed in this work was applied to AFAM measurements on silicon, zerodur, and strontium titanate.

  19. Analysis of the FELIX experiments with cantilevered beams and hollow cylinders

    International Nuclear Information System (INIS)

    Turner, L.R.; Hua, T.Q.; Lee, S.-Y.

    1986-01-01

    Experiments have been performed with the FELIX facility at Argonne National Laboratory to study the coupling between eddy currents and deflections and to provide data for validating eddy current computer programs. Experiments with cantilevered beams in crossed steady and decaying magnetic fields verify that coupling effects act to alleviate the large currents, deflections, and stresses predicted by uncoupled analyses. Measurements of magnetic fields induced in conducting hollow cylinders are analyzed by exponential fitting and by transfer functions. Spatial variation in the parameters of the exponential fit and in those of the one-and two-pole transfer functions suggests that several eddy current modes are acting in the cylinder test pieces. (author)

  20. Analysis of the FELIX experiments with cantilevered beams and hollow cylinders

    International Nuclear Information System (INIS)

    Turner, L.R.; Hua, T.Q.; Lee, S.Y.

    1986-01-01

    Experiments have been performed with the FELIX facility at Argonne National Laboratory to study the coupling between eddy currents and deflections and to provide data for validating eddy current computer programs. Experiments with cantilevered beams in crossed steady and decaying magnetic fields verify that coupling effects act to alleviate the large currents, deflections, and stresses predicted by uncoupled analyses. Measurements of magnetic fields induced in conducting hollow cylinders are analyzed by exponential fitting and by transfer functions. Spatial variation in the parameters of the exponential fit and in those of the one- and two-pole transfer functions suggests that several eddy current modes are acting in the cylinder test pieces

  1. Highly sensitive polymer-based cantilever-sensors for DNA detection

    Energy Technology Data Exchange (ETDEWEB)

    Calleja, M. [Biosensors Group, Nacional Center of Microelectronics (CNM-CSIC), Isaac Newton 8, Tres Cantos, E-28760 Madrid (Spain) and Mikroelektronics Centret, Technical University of Denmark, 345E, DK-2800, Lyngby (Denmark)]. E-mail: mcalleja@imm.cnm.csic.es; Nordstroem, M. [Mikroelektronics Centret, Technical University of Denmark, 345E, DK-2800, Lyngby (Denmark); Alvarez, M. [Biosensors Group, Nacional Center of Microelectronics (CNM-CSIC), Isaac Newton 8, Tres Cantos, E-28760 Madrid (Spain); Tamayo, J. [Biosensors Group, Nacional Center of Microelectronics (CNM-CSIC), Isaac Newton 8, Tres Cantos, E-28760 Madrid (Spain); Lechuga, L.M. [Biosensors Group, Nacional Center of Microelectronics (CNM-CSIC), Isaac Newton 8, Tres Cantos, E-28760 Madrid (Spain); Boisen, A. [Mikroelektronics Centret, Technical University of Denmark, 345E, DK-2800, Lyngby (Denmark)

    2005-11-15

    We present a technology for the fabrication of cantilever arrays aimed to develop an integrated biosensor microsystem. The fabrication process is based on spin coating of the photosensitive polymer and near-ultraviolet exposure. Arrays of up to 33 microcantilevers are fabricated in the novel polymer material SU-8. The low Young's modulus of the polymer, 40 times lower than that of silicon, enables to improve the sensitivity of the sensor device for target detection. The mechanical properties of SU-8 cantilevers, such as spring constant, resonant frequency and quality factor are characterized as a function of the dimensions and the medium. The devices have been tested for measurement of the adsorption of single stranded DNA and subsequent interstitial adsorption of lateral spacer molecules. We demonstrate that sensitivity is enhanced by a factor of six compared to that of commercial silicon nitride cantilevers.

  2. A DVD-ROM based high-throughput cantilever sensing platform

    DEFF Research Database (Denmark)

    Bosco, Filippo

    and October 2011. The project was part of the Xsense research network, funded by the Strategic Danish Research Council, and supervised by Prof. Anja Boisen. The goal of the Xsense project is to design and fabricate a compact and cheap device for explosive sensing in air and liquid. Four different technologies...... of a high-throughput label-free sensor platform utilizing cantilever based sensors. These sensors have often been acclaimed to facilitate highly parallelized operation. Unfortunately, so far no concept has been presented which offers large data sets as well as easy liquid sample handling. We use optics...... and mechanics from a DVD player to handle liquid samples and to read-out cantilever deflection and resonant frequency. In a few minutes, several liquid samples can be analyzed in parallel, measuring over several hundreds of individual cantilevers. Three generations of systems have been developed and tested...

  3. Highly tunable NEMS shallow arches

    KAUST Repository

    Kazmi, Syed N. R.

    2017-11-30

    We report highly tunable nanoelectromechanical systems NEMS shallow arches under dc excitation voltages. Silicon based in-plane doubly clamped bridges, slightly curved as shallow arches, are fabricated using standard electron beam lithography and surface nanomachining of a highly conductive device layer on a silicon-on-insulator wafer. By designing the structures to have gap to thickness ratio of more than four, the mid-plane stretching of the nano arches is maximized such that an increase in the dc bias voltage will result into continuous increase in the resonance frequency of the resonators to wide ranges. This is confirmed analytically based on a nonlinear beam model. The experimental results are found to be in good agreement with that of the results from developed analytical model. A maximum tunability of 108.14% for a 180 nm thick arch with an initially designed gap of 1 μm between the beam and the driving/sensing electrodes is achieved. Furthermore, a tunable narrow bandpass filter is demonstrated, which opens up opportunities for designing such structures as filtering elements in high frequency ranges.

  4. A novel fabrication technique for free-hanging homogeneous polymeric cantilever waveguides

    International Nuclear Information System (INIS)

    Nordström, Maria; Hübner, Jörg; Boisen, Anja; Calleja, Montserrat

    2008-01-01

    We present a novel bonding technique developed for the fabrication of a cantilever-based biosensing system with integrated optical read-out. The read-out mechanism is based on single-mode waveguides fabricated monolithically in SU-8. For optimal operation of the read-out mode, the cantilever waveguides should be homogenous and this bonding technique ensures free-hanging cantilevers that are surrounded by the same material for bottom and top claddings. The bonding step is necessary because SU-8 is a negative resist where free-hanging structures cannot be fabricated directly. This paper gives details on the processing aspects and the parameters of the fabrication steps

  5. Performance Analysis of Wind-Induced Piezoelectric Vibration Bimorph Cantilever for Rotating Machinery

    Directory of Open Access Journals (Sweden)

    Gongbo Zhou

    2015-01-01

    Full Text Available Harvesting the energy contained in the running environment of rotating machinery would be a good way to supplement energy to the wireless sensor. In this paper, we take piezoelectric bimorph cantilever beam with parallel connection mode as energy collector and analyze the factors which can influence the generation performance. First, a modal response theory model is built. Second, the static analysis, modal analysis, and piezoelectric harmonic response analysis of the wind-induced piezoelectric bimorph cantilever beam are given in detail. Finally, an experiment is also conducted. The results show that wind-induced piezoelectric bimorph cantilever beam has low resonant frequency and stable output under the first modal mode and can achieve the maximum output voltage under the resonant condition. The output voltage increases with the increase of the length and width of wind-induced piezoelectric bimorph cantilever beam, but the latter increasing amplitude is relatively smaller. In addition, the output voltage decreases with the increase of the thickness and the ratio of metal substrate to piezoelectric patches thickness. The experiment showed that the voltage amplitude generated by the piezoelectric bimorph cantilever beam can reach the value simulated in ANSYS, which is suitable for actual working conditions.

  6. Mycotic Aneurysm of the Aortic Arch

    Directory of Open Access Journals (Sweden)

    Ji Hye Seo

    2014-08-01

    Full Text Available A mycotic aneurysm of the thoracic aorta is rare. We report a case of mycotic aneurysm that developed in the aortic arch. An 86-year-old man was admitted with fever and general weakness. Blood culture yielded methicillin-resistant Staphylococcus aureus. Chest X-ray showed an enlarged aortic arch, and computed tomography scan revealed an aneurysm in the aortic arch. The patient was treated only with antibiotics and not surgically. The size of the aneurysm increased rapidly, resulting in bronchial obstruction and superimposed pneumonia. The patient died of respiratory failure.

  7. Force systems in the initial phase of orthodontic treatment -- a comparison of different leveling arch wires.

    Science.gov (United States)

    Fuck, Lars-Michael; Drescher, Dieter

    2006-01-01

    The determination of orthodontically-effective forces and moments places great demands on the technical equipment. Many patients report severe pain after fixed appliance insertion. Since it is assumed that pain from orthodontic appliances is associated with the force and moment levels applied to the teeth and since the occurrence of root resorption is a common therapeutic side effect, it would seem important to know the actual magnitudes of the components of the active orthodontic force systems. The aim of the present study was therefore to measure initial force systems produced by different leveling arch-wires in a complete multi-bracket appliance and to assess whether force and moment levels can be regarded as biologically acceptable or not. The actual bracket position in 42 patients was transferred onto a measurement model. Forces and moments produced by a super-elastic nickel-titanium (NiTi) archwire, a 6-strand stainless steel archwire, and a 7-strand super-elastic NiTi archwire were determined experimentally on different teeth. Average forces and moments produced by the super-elastic NiTi arch wires were found to be the highest. In spite if their larger diameter, the stranded arch wires' average force and moment levels were lower, especially that of the stranded super-elastic archwire. Nevertheless, maximum force levels sometimes exceeded recommended values in the literature and must be considered as too high. The measured arch wires' initial force systems differed significantly depending on the type of archwire and its material structure. Stranded arch wires produced lower force and moment levels, and we recommend their use in the initial phase of orthodontic treatment.

  8. Indium phosphide-based monolithically integrated PIN waveguide photodiode readout for resonant cantilever sensors

    Energy Technology Data Exchange (ETDEWEB)

    Siwak, N. P. [Department of Electrical and Computer Engineering, Institute for Systems Research, University of Maryland, College Park, Maryland 20742 (United States); Laboratory for the Physical Sciences, 8050 Greenmead Drive, College Park, Maryland 20740 (United States); Fan, X. Z.; Ghodssi, R. [Department of Electrical and Computer Engineering, Institute for Systems Research, University of Maryland, College Park, Maryland 20742 (United States); Kanakaraju, S.; Richardson, C. J. K. [Laboratory for the Physical Sciences, 8050 Greenmead Drive, College Park, Maryland 20740 (United States)

    2014-10-06

    An integrated photodiode displacement readout scheme for a microelectromechanical cantilever waveguide resonator sensing platform is presented. III-V semiconductors are used to enable the monolithic integration of passive waveguides with active optical components. This work builds upon previously demonstrated results by measuring the displacement of cantilever waveguide resonators with on-chip waveguide PIN photodiodes. The on-chip integration of the readout provides an additional 70% improvement in mass sensitivity compared to off-chip photodetector designs due to measurement stability and minimized coupling loss. In addition to increased measurement stability, reduced packaging complexity is achieved due to the simplicity of the readout design. We have fabricated cantilever waveguides with integrated photodetectors and experimentally characterized these cantilever sensors with monolithically integrated PIN photodiodes.

  9. Cantilever contribution to the total electrostatic force measured with the atomic force microscope

    International Nuclear Information System (INIS)

    Guriyanova, Svetlana; Golovko, Dmytro S; Bonaccurso, Elmar

    2010-01-01

    The atomic force microscope (AFM) is a powerful tool for surface imaging at the nanometer scale and surface force measurements in the piconewton range. Among long-range surface forces, the electrostatic forces play a predominant role. They originate if the electric potentials of the substrate and of the tip of the AFM cantilever are different. A quantitative interpretation of the AFM signal is often difficult because it depends in a complicated fashion on the cantilever–tip–surface geometry. Since the electrostatic interaction is a long-range interaction, the cantilever, which is many microns from the surface, contributes to the total electrostatic force along with the tip. Here we present results of the electrostatic interaction between a conducting flat surface and horizontal or tilted cantilevers, with and without tips, at various distances from the surface. As addressed in a previous work, we show that the contribution of the cantilever to the overall force cannot be neglected. Based on a predictive model and on 3D confocal measurements, we discuss the influence of the tilting angle of the cantilever

  10. Anchorage onto deciduous teeth: effectiveness of early rapid maxillary expansion in increasing dental arch dimension and improving anterior crowding.

    Science.gov (United States)

    Mutinelli, Sabrina; Manfredi, Mario; Guiducci, Antonio; Denotti, Gloria; Cozzani, Mauro

    2015-01-01

    Anchorage onto permanent dentition is a common procedure in rapid maxillary expansion. However, replacing first permanent molars with the second deciduous molars seems to be an option to reduce some negative side effects during orthodontic treatment. The purpose of this study was to evaluate the dental effect of rapid maxillary expansion with anchorage exclusively onto deciduous teeth performed in the first period of transition. Twenty patients with a lateral cross-bite treated exclusively by a Haas expander in early mixed dentition were retrospectively analyzed before treatment, at appliance removal, and at 21 months out of retention. The sagittal and transverse dimensions, together with the inter-canine arch and irregularity index, were digitally measured on scanned images of dental casts. The patients were compared with three balanced control groups (in total, 60 individuals) matched for gender. Two control groups had the same canine dental class as the treated group at T1, were in the inter-transitional period, and either had or lacked a lateral cross-bite. The last control group was comprised of adolescents in permanent dentition with a dental class I. The statistical analysis was performed by means of repeated-measures ANOVA for paired data and one-way ANOVA, the Kruskal-Wallis test, and the Mann-Whitney test for independent measures (α-level p dentition), the dental arch dimensions of treated patients were similar to those of adolescents with a dental class I and significantly wider than those of patients with a lateral cross-bite. Also, the anterior irregularity index was lower among patients who had undergone expansion treatments than in all untreated study participants. The Haas expander anchored to the deciduous teeth is effective in increasing the dental arch width in patients with a lateral cross-bite. The dimensions of the dental arch were modified earlier toward the values of the permanent dentition.

  11. Vibrational fatigue failures in short cantilevered piping with socket-welding fittings

    International Nuclear Information System (INIS)

    Smith, J.K.

    1996-01-01

    Approximately 80% of the vibrational fatigue failures in nuclear power plants have been caused by high cycle vibrational fatigue. Many of these failures have occurred in short, small bore (2 in. nominal diameter and smaller), unbraced, cantilevered piping with socket-welding fittings. The fatigue failures initiated in the socket welds. These failures have been unexpected, and have caused costly, unscheduled outages in some cases. In order to reduce the number of vibrational fatigue failures in these short cantilevered pipes, an acceleration based vibrational fatigue screening criteria was developed under Electric Power Research Institute (EPRI) sponsorship. In this paper, the acceleration based criteria will be compared to the results obtained from detailed dynamic modeling of a short, cantilevered pipe

  12. Posttreatment quantification of patient experiences with full-arch implant treatment using a modification of the OHIP-14 questionnaire.

    Science.gov (United States)

    Babbush, Charles A

    2012-06-01

    Patient well-being is always the goal of rehabilitation of edentulism; however, evaluations of treatment success often overlook the patient's subjective feelings about comfort, function, speech, social image, social inhibitions, psychological discomfort, and/or disabilities. The purpose of this study was to assess these patient responses using an oral health questionnaire. To assess such feelings, a self-administered 20-question multiple-choice patient-reported Edentulous Patient Impact Questionnaire was developed, based upon the previously validated Oral Health Impact Profile patient-assessment tool. Responses were solicited from randomly selected patients treated with an implant-supported, fixed, immediately loaded full arch prosthesis. The questionnaires were completed by 250 patients. Of the respondents, 95% described themselves as being either extremely satisfied (74%) or satisfied (21%) with their new teeth, and 98% said they would definitely recommend similar treatment (88%) or consider recommending it (10%) to a friend or colleague. Based upon an oral health impact survey completed by 250 patients treated with full-arch implant-supported, immediately loaded fixed dental prostheses, it appears that patient satisfaction is high and that treated patients would generally be willing to recommend this treatment to others.

  13. Study on load test of 100m cross-reinforced deck type concrete box arch bridge

    Science.gov (United States)

    Shi, Jing Xian; Cheng, Ying Jie

    2018-06-01

    Found in the routine quality inspection of highway bridge that many vertical fractures on the main beam (10mT beam) of the steel reinforced concrete arch bridge near the hydropower station. In order to grasp the bearing capacity of this bridge under working conditions with cracks, the static load and dynamic load test of box arch bridge are carried out. The Midas civil theory is calculated by using the special plate trailer - 300 as the calculation load, and the deflection and stress of the critical section are tested by the equivalent cloth load in the test vehicle. The pulsation test, obstacles and no obstacle driving test were carried out. Experimental results show that the bridge under the condition of the test loads is in safe condition, main bearing component of the strength and stiffness meet the design requirements, the crack width does not increase, in the process of loading bridge overall work performance is good.

  14. 2D MEMS electrostatic cantilever waveguide scanner for potential image display application

    Directory of Open Access Journals (Sweden)

    Gu Kebin

    2015-01-01

    Full Text Available This paper presents the current status of our micro-fabricated SU-8 2D electrostatic cantilever waveguide scanner. The current design utilizes a monolithically integrated electrostatic push-pull actuator. A 4.0 μm SU-8 rib waveguide design allows a relatively large core cross section (4μm in height and 20 μm in width to couple with existing optical fiber and a broad band single mode operation (λ= 0.7μm to 1.3μm with minimal transmission loss (85% to 87% output transmission efficiency with Gaussian beam profile input. A 2D scanning motion has been successfully demonstrated with two fundamental resonances found at 202 and 536 Hz in vertical and horizontal directions. A 130 μm and 19 μm, corresponding displacement and 0.062 and 0.009 rad field of view were observed at a +150V input. Beam divergence from the waveguide was corrected by a focusing GRIN lens and a 5μm beam diameter is observed at the focal plane. The transmission efficiency is low (~10% and cantilever is slightly under tensile residual stress due to inherent imperfection in the process and tooling in fabrication. However, 2D light scanning pattern was successfully demonstrated using 1-D push-pull actuation.

  15. A new detection system for extremely small vertically mounted cantilevers

    International Nuclear Information System (INIS)

    Antognozzi, M; Ulcinas, A; Picco, L; Simpson, S H; Miles, M J; Heard, P J; Szczelkun, M D; Brenner, B

    2008-01-01

    Detection techniques currently used in scanning force microscopy impose limitations on the geometrical dimensions of the probes and, as a consequence, on their force sensitivity and temporal response. A new technique, based on scattered evanescent electromagnetic waves (SEW), is presented here that can detect the displacement of the extreme end of a vertically mounted cantilever. The resolution of this method is tested using different cantilever sizes and a theoretical model is developed to maximize the detection sensitivity. The applications presented here clearly show that the SEW detection system enables the use of force sensors with sub-micron size, opening new possibilities in the investigation of biomolecular systems and high speed imaging. Two types of cantilevers were successfully tested: a high force sensitivity lever with a spring constant of 0.17 pN nm -1 and a resonant frequency of 32 kHz; and a high speed lever with a spring constant of 50 pN nm -1 and a resonant frequency of 1.8 MHz. Both these force sensors were fabricated by modifying commercial microcantilevers in a focused ion beam system. It is important to emphasize that these modified cantilevers could not be detected by the conventional optical detection system used in commercial atomic force microscopes

  16. Mechanism Research of Arch Dam Abutment Forces during Overload

    Directory of Open Access Journals (Sweden)

    Yu Xia

    2015-01-01

    Full Text Available This paper presents research on the abutment forces of a double-curvature arch dam during overload based on numerical calculation results obtained through finite element method by Ansys. Results show that, with an increase in elevation, the abutment forces and bending moment of the arch dam increase first and then decrease from the bottom to the top of the dam. Abutment forces and bending moment reach their maximum at the middle or middle-down portion of the dam. The distributions of abutment forces and moment do not change during overload. The magnitude of each arch layer’s forces and moment increases linearly during overload. This result indicates that each arch layer transmits bearing loads to the rocks of the left and right banks steadily. This research explains the operating mechanism of an arch dam under normal and overload conditions. It provides a simple method to calculate the distribution of forces Fx and Fy and a new method to calculate the overload factor of an arch dam through the estimation of arch layers based on the redistribution characteristic of arch abutment forces.

  17. [Outcomes of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures].

    Science.gov (United States)

    Wang, Mian; Chang, Guangqi; Yin, Henghui; Yao, Chen; Wang, Jinsong; Wang, Shenming

    2015-11-01

    To summarize the experience of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures. It was a retrospective study. From January 2002 to December 2014, 42 high risk patients with aortic arch disease were treated by supra-arch debranching hybrid with subsequent endovascular repair in the First Affiliated Hospital of Sun Yat-sen University. There were 39 male and 3 female patients with a mean age of (53±13) years (ranging from 34 to 80 years). Of the 42 patients, 7 were thoracic aortic aneurysm, 20 were Stanford type B aortic dissection and 15 were Stanford type A aortic dissection. After the supra-aortic debranching technique, simultaneous (n=16) or staged (n=26, mean interval (7±3) days) endovascular repair were performed. Fisher exact test was used to compare the in-hospital mortality of ascending aorta based debranching and non-ascending aorta based debranching. Technical success rate was 81.0% (34/42). The overall 30-day complication rate was 31.0% (13/42), including 3 cerebral stroke (7.1%), 8 endoleak (19.0%, including 6 type I endoleak and 2 type II endoleak), 1 circulatory failure, 1 aorto-tracheal fistula. The 30-day mortality was 9.5% (4/42), 2 died of cerebral stroke, 1 died of circulatory failure, 1 died of aorto-tracheal fistula. The in-hospital mortality of ascending aorta based debranching group was obviously higher than that of the non-ascending aorta based debranching group (4/16 vs. 0, P=0.02). The median time of follow-up was 64.8 (2 to 156.9) months. CT scanning was performed at 1, 3 months after surgery and annually thereafter. The overall survival rate was 76.6%. During the follow-up period, there was 4 deaths, and 2 of them were aortic artery related (5.3%). There were 4 de novo complications during the follow-up period, 1 stroke attributed to bypass occlusion was cured by medical treatment, 2 pseudoaneurysm was successfully treated with open surgery, 1 stent-graft induced new distal entry tear was

  18. Multi-frequency response from a designed array of micromechanical cantilevers fabricated using a focused ion beam

    International Nuclear Information System (INIS)

    Ghatnekar-Nilsson, S; Graham, J; Hull, R; Montelius, L

    2006-01-01

    We demonstrate arrays of cantilevers with different lengths, fabricated by focused ion beam milling. The arrays of oscillators generate a spectrum of different resonant frequencies, where each frequency correlates to the corresponding individual cantilever. The frequency response from all the cantilevers is collected from a single measurement under the same environment and conditions for the entire array. The mass response of the system generated the same Δf/f 0 for the cantilevers, within 0.1% accuracy. We denote the method MFSAC: multi-frequency signal analysis from an array of cantilevers. The simultaneous detection of several frequencies in one spectrum has great benefits in mass sensor applications, offering the possibility for true label-free detection

  19. Glossary to ARCH (GARCH)

    DEFF Research Database (Denmark)

    Bollerslev, Tim

    The literature on modeling and forecasting time-varying volatility is ripe with acronyms and abbreviations used to describe the many different parametric models that have been put forth since the original linear ARCH model introduced in the seminal Nobel Prize winning paper by Engle (1982......).  The present paper provides an easy-to-use encyclopedic reference guide to this long list of ARCH acronyms.  In addition to the acronyms associated with specific parametric models, I have also included descriptions of various abbreviations associated with more general statistical procedures and ideas...

  20. Highly Sensitive Polymer-based Cantilever-sensors for DNA Detection

    DEFF Research Database (Denmark)

    Gomez, Montserrat; Nordström, Maria; Alvarez, M.

    2005-01-01

    We present a technology for the fabrication of cantilever arrays aimed to develop an integrated biosensor microsystem. The fabrication process is based on spin coating of the photosensitive polymer and near-ultraviolet exposure. Arrays of up to 33 microcantilevers are fabricated in the novel...... polymer material SU-8. The low Young's modulus of the polymer, 40 times lower than that of silicon, enables to improve the sensitivity of the sensor device for target detection. The mechanical properties of SU-8 cantilevers, such as spring constant, resonant frequency and quality factor are characterized...

  1. Squeeze-film damping characteristics of cantilever microresonators ...

    African Journals Online (AJOL)

    user

    perturbation approach does not apply to cantilever plates because of ...... Direct coupling of electrostatic and structural domain has been achieved using ... forces are computed to obtain the modal squeeze stiffness and damping parameters.

  2. A segmented appliance for space closure followed by Invisalign and fixed appliances.

    Science.gov (United States)

    Uribe, Flavio; Cutrera, Alice; Nanda, Ravinda

    2011-01-01

    This case report describes the use of a segmented appliance for space closure prior to using Invisalign. The maxillary right canine was retracted into the extracted first premolar space with a sectional wire from the first molar to the canine with no visible brackets in the incisor region. The advantage of this technique is the ability to achieve better root and rotational control during space closure with a fixed appliance that also has limited visibility. A maxillary fixed appliance was used to refine the esthetics in the maxillary arch due to the limitations of the Invisalign appliance in achieving rotational and vertical movements.

  3. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    Science.gov (United States)

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  4. Occlusal stability in shortened dental arches.

    NARCIS (Netherlands)

    Witter, D.J.; Creugers, N.H.J.; Kreulen, C.M.; Haan, A. de

    2001-01-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a

  5. Integrated MOSFET-Embedded-Cantilever-Based Biosensor Characteristic for Detection of Anthrax Simulant

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, Salwa [University of Tennessee, Knoxville (UTK); Lee, Ida [ORNL; Islam, Syed K [University of Tennessee, Knoxville (UTK); Eliza, Sazia A. [University of Tennessee, Knoxville (UTK); Shekhawat, Gajendra [Northwestern University, Evanston; Dravid, Vinayak [Northwestern University, Evanston; Tulip, Fahmida S [ORNL

    2011-01-01

    In this work, MOSFET-embedded cantilevers are configured as microbial sensors for detection of anthrax simulants, Bacillus thuringiensis. Anthrax simulants attached to the chemically treated gold-coated cantilever cause changes in the MOSFET drain current due to the bending of the cantilever which indicates the detection of anthrax simulant. Electrical properties of the anthrax simulant are also responsible for the change in the drain current. The test results suggest a detection range of 10 L of stimulant test solution (a suspension population of 1.3 107 colony-forming units/mL diluted in 40% ethanol and 60% deionized water) with a linear response of 31 A/ L.

  6. Self-mixing interferometry in vertical-cavity surface-emitting lasers for nanomechanical cantilever sensing

    DEFF Research Database (Denmark)

    Larsson, David; Greve, Anders; Hvam, Jørn Märcher

    2009-01-01

    We have experimentally investigated self-mixing interference produced by the feedback of light from a polymer micrometer-sized cantilever into a vertical-cavity surface-emitting laser for sensing applications. In particular we have investigated how the visibility of the optical output power...... and the junction voltage depends on the laser injection current and the distance to the cantilever. The highest power visibility obtained from cantilevers without reflective coatings was 60%, resulting in a very high sensitivity of 45 mV/nm with a noise floor below 1.2 mV. Different detection schemes are discussed....

  7. Optical device comprising a cantilever and method of fabrication and use thereof

    NARCIS (Netherlands)

    Iannuzzi, Davide; Deladi, S.; Elwenspoek, Michael Curt

    2008-01-01

    The present invention provides an optical device, comprising an optical fiber and a cantilever that is arranged on an end of the optical fiber; The cantilever may be an integral part of the optical fiber, and may have a length that is substantially equal to a diameter of the optical fiber.

  8. Optical device comprising a cantilever and method of fabrication and use thereof

    NARCIS (Netherlands)

    Iannuzzi, Davide; Deladi, S.; Elwenspoek, Michael Curt

    2011-01-01

    The present invention provides an optical device, comprising an optical fiber and a cantilever that is arranged on an end of the optical fiber; The cantilever may be an integral part of the optical fiber, and may have a length that is substantially equal to a diameter of the optical fiber.

  9. [Rare earth magnets in conjunction with fixed orthodontics. An "attractive" solution for the positioning of impacted teeth].

    Science.gov (United States)

    Dereudre, B

    2001-11-01

    Two rare earth permanent magnets are used to align impacted teeth: one is bonded on the crown of the ectopic tooth, the other, intraoral, guides the impacted tooth to the desired place by its attractive power. The intraoral magnet is fixed to an edgewise arch. The adjustments allowed by fixed appliance create better final tooth position than with removable appliance. Our experience depicts an improvement of stability in results and a diminution of periodontal breakdown.

  10. Calibration of optical cantilever deflection readers

    International Nuclear Information System (INIS)

    Hu Zhiyu; Seeley, Tim; Kossek, Sebastian; Thundat, Thomas

    2004-01-01

    Because of its ultrahigh sensitivity, the optical lever detection method similar to that used in the atomic force microscope (AFM) has been widely employed as a standard technique for measuring microcantilever deflection. Along with the increasing interest in using the microcantilever as a sensing platform, there is also a requirement for a reliable calibration technique. Many researchers have used the concept of optical lever detection to construct microcantilever deflection readout instruments for chemical, physical, and biological detection. However, without an AFM piezo z scanner, it is very difficult to precisely calibrate these instruments. Here, we present a step-by-step method to conveniently calibrate an instrument using commercially available piezoresistive cantilevers. The experimental results closely match the theoretical calculation. Following this procedure, one can easily calibrate any optical cantilever deflection detection system with high reproducibility, precision, and reliability. A detailed discussion of the optical lever readout system design has been addressed in this article

  11. Optimization of Q-factor of AFM cantilevers using genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Cruz, Angel, E-mail: elapc27@gmail.com [Faculty of Engineering, Universidad Autonoma de Queretaro, Queretaro (Mexico); Dominguez-Gonzalez, Aurelio [Faculty of Engineering, Universidad Autonoma de Queretaro, Queretaro (Mexico); Stiharu, Ion [Department of Mechanical and Industrial Engineering, Concordia University, Montreal (Canada); Osornio-Rios, Roque A. [Faculty of Engineering, Universidad Autonoma de Queretaro, Queretaro (Mexico)

    2012-04-15

    Micro cantilever beams have been intensively used in sensing applications including to scanning profiles and surfaces where there resolution and imaging speed are critical. Force resolution is related to the Q-factor. When the micro-cantilever operates in air with small separation gaps, the Q-factor is even more reduced due to the squeeze-film damping effect. Thus, the optimization of the configuration of an AFM micro-cantilever is presented in this work with the objective of improving its Q-factor. To accomplish this task, we propose the inclusion of holes as breathing chimneys in the initial design to reduce the squeeze-film damping effect. The evaluation of the Q-factor was carried out using finite element model, which is implemented to work together with the squeeze-film damping model. The methodology applied in the optimization process was genetic algorithms, which considers as constraints the maximum allowable stress, fundamental frequency and spring constant with respect to the initial design. The results show that the optimum design, which includes holes with an optimal location, increases the Q-factor almost five times compared to the initial design. -- Highlights: Black-Right-Pointing-Pointer It was optimized the Q-factor of a cantilever, which operates near to the surface in air. Black-Right-Pointing-Pointer It was proposed the inclusion of holes as breathing chimneys in the cantilever's surface. Black-Right-Pointing-Pointer Genetic algorithms and finite element analysis were applied to find the optimum configuration for the Q-factor. Black-Right-Pointing-Pointer Optimum design keeps first frequency and the spring constant very close to the original and has a better force resolution. Black-Right-Pointing-Pointer Final design can be easily manufactured through a mask.

  12. Scanning probe microscopy with vertically oriented cantilevers made easy

    International Nuclear Information System (INIS)

    Valdrè, G; Moro, D; Ulian, G

    2012-01-01

    Non-contact imaging in scanning probe microscopy (SPM) is becoming of great importance in particular for imaging biological matter and in general soft materials. Transverse dynamic force microscopy (TDFM) is an SPM-based methodology that exploiting a cantilever oriented in a vertical configuration with respect to the sample surface may work with very low tip to sample interaction forces. The probe is oscillated parallel to the sample surface, usually by a piezoelectric element. However, this methodology often requires complex microscope setups and detection systems, so it is usually developed in specific laboratories as a prototype microscope. Here, we present a very simple device that easily enables a commercial SPM head to be oriented in such a way to have the cantilever long axis perpendicular to the sample surface. No modifications of the SPM hardware and software are required and commercial available cantilevers can be used as probes. Performance tests using polystyrene spheres, muscovite crystallographic steps and DNA single molecules were successful and all resulted in agreement with other TDFM and SPM observations demonstrating the reliability of the device. (paper)

  13. Comparison of Arch Width Changes Following Orthodontic ...

    African Journals Online (AJOL)

    2015-11-21

    Nov 21, 2015 ... Materials and Methods: The study was conducted with pre- and post-treatment digital models from ... or posterior arch width following orthodontic treatment ..... premolar extraction cases show significant arch width increases in ...

  14. GaAs/AlAs/InGaP heterostructure: a versatile material basis for cantilever designs

    International Nuclear Information System (INIS)

    Gregušová, Dagmar; Kúdela, Róbert; Eliáš, Peter; Šoltýs, Ján; Cambel, Vladimír; Kostič, Ivan

    2010-01-01

    We report on the design, fabrication and initial mechanical testing of cantilevers with tips based on a GaAs/In 0.485 Ga 0.515 P/AlAs heterostructure grown by metal organic chemical vapor deposition. They were produced using a dedicated technological process based on (1) the formation of integrated tips through an AlAs-assisted surface sacrificial wet-etching process and (2) the GaAs cantilever release fully protected between two InGaP etch-stop layers. 2 µm thick InGaP/GaAs/InGaP cantilevers had integrated pyramidal tips with the sides at ∼45° to (1 0 0). Metallic elements were processed close to the tip apexes using non-standard optical lithography. The cantilever release was accomplished using photolithography, Ar ion milling of InGaP and wet chemical etching of GaAs via resist layers deposited by a draping technique. A tip–cantilever prototype with length, width and thickness of 150, 35 and 2 µm, respectively, exhibited a resonance frequency of 66.2 kHz, which correlated well with a theoretical value of 57 kHz for a GaAs cantilever of identical dimensions. (technical note)

  15. Effect of aging on the configurational change of the aortic arch

    Directory of Open Access Journals (Sweden)

    Atsuhiro Kojima

    2016-04-01

    Full Text Available We explored the relationship between aging and the configuration of the aortic arch using computed tomography angiography (CTA. We retrospectively reviewed CTA obtained in 140 cases. The configuration of the aortic arch was categorized into three types based on the criteria mentioned by Madhwal et al., and the relationships between each configuration and patient characteristics were analyzed. Anomalies of the aortic arch were also explored. Twenty patients had a type-1 aortic arch (mean age, 56.1 years, 30 patients had a type-2 aortic arch (mean age, 66.3 years, and 89 patients had a type-3 aortic arch (mean age, 71.7 years. The mean age of patients with a type-3 aortic arch was significantly higher than that of patients with a type-1 aortic arch. No significant correlations between the type of aortic arch and other factors, such as smoking habit, were seen. The configuration of the aortic arch in our study appears to be significantly affected by the age of the patients.

  16. An AlN cantilever for a wake-up switch triggered by air pressure change

    International Nuclear Information System (INIS)

    Kaiho, Y; Itoh, T; Maeda, R; Takahashi, H; Matsumoto, K; Shimoyama, I; Tomimatsu, Y; Kobayashi, T

    2013-01-01

    This research reports an AlN cantilever with an air chamber for a wake-up switch triggered by air pressure change. The proposed sensor is designed to fulfil both high sensitivity and low power consumption. By combining an air chamber to the one side of the AlN cantilever surface, the barometric pressure change generates a piezoelectric voltage. Thus, a wake-up switch triggered by air pressure change can be achieved using an AlN cantilever. The size of the fabricated AlN cantilever was 2000 μm × 1000 μm × 2 μm. The sensitivity to static differential pressure was 11.5 mV/Pa at the range of −20 Pa to 20 Pa. We evaluated the response of the sensor, which was composed of the AlN cantilever and the chamber of 60 ml in volume, when air pressure change was applied. The output voltage increased with increasing the applied air pressure change. It was observed that the maximum output voltage of 50 mV was generated when the air pressure change was 13 Pa

  17. Clarifying the anatomy of the fifth arch artery

    Directory of Open Access Journals (Sweden)

    Saurabh Kumar Gupta

    2016-01-01

    Full Text Available The artery allegedly forming in the fifth pharyngeal arch has increasingly been implicated as responsible for various vascular malformations in patients with congenitally malformed hearts. Observations from studies on developing embryos, however, have failed to provide support to substantiate several of these inferences such that the very existence of the fifth arch artery remains debatable. To the best of our knowledge, in only a solitary human embryo has a vascular channel been found that truly resembled the artery of the fifth arch. Despite the meager evidence to support its existence, the fifth arch artery has been invoked to explain the morphogenesis of double-barreled aorta, some unusual forms of aortopulmonary communications, and abnormalities of the brachiocephalic arteries. In most of these instances, the interpretations have proved fallible when examined in the light of existing knowledge of cardiac development. In our opinion, there are more plausible alternative explanations for the majority of these descriptions. Double-barreled aorta is more likely to result from retention of the recently identified dorsal collateral channels while abnormalities of brachiocephalic arteries are better explained on the basis of extensive remodeling of aortic arches during fetal development. Some examples of aortopulmonary communications, nonetheless, may well represent persistence of the developing artery of the fifth pharyngeal arch. We here present one such case - a patient with tetralogy of Fallot and pulmonary atresia, in whom the fifth arch artery provided a necessary communication between the ascending aorta and the pulmonary arteries. In this light, we discuss the features we consider to be essential before attaching the tag of "fifth arch artery" to a candidate vascular channel.

  18. Cantilever-based bio-chemical sensor integrated in a microliquid handling system

    DEFF Research Database (Denmark)

    Thaysen, Jacob; Marie, Rodolphe; Boisen, Anja

    2001-01-01

    The cantilevers have integrated piezoresistive readout which, compared to optical readout, enables simple measurements on even non-transparent liquids, such as blood. First, we introduce a simple theory for using piezoresistive cantilevers as surface stress sensors. Then, the sensor fabrication...... based on conventional microfabrication is described and the sensor characterization is discussed. During the characterization we found a stress sensitivity of (ΔR/R)=4.6:10 -4 (N/m)-1 and a minimum detectable surface stress change of 2.6 mN/m. Aqua regia etch of gold on top of the cantilevers has been...... monitored, and immobilization of single-stranded thiol modified DNA-oligos has been detected by the sensor. Finally, it is demonstrated that it is possible to analyze two samples simultaneously by utilizing the laminar flow in the microliquid handling system....

  19. Nonstationary ARCH and GARCH with t-distributed Innovations

    DEFF Research Database (Denmark)

    Pedersen, Rasmus Søndergaard; Rahbek, Anders

    Consistency and asymptotic normality are established for the maximum likelihood estimators in the nonstationary ARCH and GARCH models with general t-distributed innovations. The results hold for joint estimation of (G)ARCH effects and the degrees of freedom parameter parametrizing the t-distribut......Consistency and asymptotic normality are established for the maximum likelihood estimators in the nonstationary ARCH and GARCH models with general t-distributed innovations. The results hold for joint estimation of (G)ARCH effects and the degrees of freedom parameter parametrizing the t......-distribution. With T denoting sample size, classic square-root T-convergence is shown to hold with closed form expressions for the multivariate covariances....

  20. Self-mixing interferometry in vertical-cavity surface-emitting lasers for nanomechanical cantilever sensing

    Science.gov (United States)

    Larsson, David; Greve, Anders; Hvam, Jørn M.; Boisen, Anja; Yvind, Kresten

    2009-03-01

    We have experimentally investigated self-mixing interference produced by the feedback of light from a polymer micrometer-sized cantilever into a vertical-cavity surface-emitting laser for sensing applications. In particular we have investigated how the visibility of the optical output power and the junction voltage depends on the laser injection current and the distance to the cantilever. The highest power visibility obtained from cantilevers without reflective coatings was ˜60%, resulting in a very high sensitivity of 45 mV/nm with a noise floor below 1.2 mV. Different detection schemes are discussed.

  1. Numerical investigation of band gaps in 3D printed cantilever-in-mass metamaterials

    Science.gov (United States)

    Qureshi, Awais; Li, Bing; Tan, K. T.

    2016-06-01

    In this research, the negative effective mass behavior of elastic/mechanical metamaterials is exhibited by a cantilever-in-mass structure as a proposed design for creating frequency stopping band gaps, based on local resonance of the internal structure. The mass-in-mass unit cell model is transformed into a cantilever-in-mass model using the Bernoulli-Euler beam theory. An analytical model of the cantilever-in-mass structure is derived and the effects of geometrical dimensions and material parameters to create frequency band gaps are examined. A two-dimensional finite element model is created to validate the analytical results, and excellent agreement is achieved. The analytical model establishes an easily tunable metamaterial design to realize wave attenuation based on locally resonant frequency. To demonstrate feasibility for 3D printing, the analytical model is employed to design and fabricate 3D printable mechanical metamaterial. A three-dimensional numerical experiment is performed using COMSOL Multiphysics to validate the wave attenuation performance. Results show that the cantilever-in-mass metamaterial is capable of mitigating stress waves at the desired resonance frequency. Our study successfully presents the use of one constituent material to create a 3D printed cantilever-in-mass metamaterial with negative effective mass density for stress wave mitigation purposes.

  2. Fixed Full Arches Supported by Tapered Implants with Knife-Edge Thread Design and Nanostructured, Calcium-Incorporated Surface: A Short-Term Prospective Clinical Study

    Directory of Open Access Journals (Sweden)

    Soheil Bechara

    2017-01-01

    Full Text Available Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea were restored with FFA restorations and enrolled in a recall program. The final outcomes were implant survival, peri-implant bone loss, biologic/prosthetic complications, and “complication-free” survival of restorations. Results. Twenty-four patients were selected. Overall, 215 implants were inserted (130 maxilla, 85 mandible, 144 in extraction sockets and 71 in healed ridges. Thirty-six FFAs were delivered (21 maxilla, 15 mandible: 27 were immediately loaded and 9 were conventionally loaded. The follow-up ranged from 1 to 3 years. Two fixtures failed, yielding an implant survival rate of 95.9% (patient-based. A few complications were registered, for a “complication-free” survival of restorations of 88.9%. Conclusions. FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface are successful in the short term, with high survival and low complication rates; long-term studies are needed to confirm these outcomes.

  3. Morphological and dimensional characteristics of dental arch in children with beta thalassemia major

    Directory of Open Access Journals (Sweden)

    Disha Kumar

    2018-01-01

    Full Text Available Background and Objectives: The aim of this study was to examine the arch dimensions of beta thalassemia major patients in comparison with normal individuals. Materials and Methods: Dental arch dimensions were compared between thalassemic patients and normal individuals in the age group of 12–16 years in the maxillary and mandibular arch corresponding to each other regarding age, sex and Angle's molar relationship. A total number of sixty cases in each group were taken. Maxillary and mandibular impressions were made with alginate for all the sixty participants in each group and poured with die stone. Measurement of inter incisor, inter canine, inter premolar and intermolar arch width, arch depth, right anterior, right posterior, left anterior, and left posterior arch length was carried out from each cast using digital Vernier caliper.Results: Unpaired t-test was used for comparison between the two groups. Statistically, a significant difference was found between the case and control groups in the maxillary arch in intercanine width, inter premolar width, intermolar width, right anterior arch length, right posterior arch length, and left anterior arch length. However, no statistically significant difference was found between the groups in inter incisor width, left posterior arch length, and arch depth in the maxillary arch. In the mandibular arch, statistically significant difference was found between the case and control groups in inter canine width, inter premolar width, inter molar width, and left anterior arch length. However, no statistically significant difference was found between the case and control groups in the mandibular arch in interincisor width, right anterior arch length, right posterior arch length, and left posterior arch length. Conclusion: Dental arch widths and arch lengths were significantly reduced in thalassemic patients as compared to normal individuals for the maxillary and mandibular arches.

  4. Experimental Determination of Bending Resonances of Millimeter Size PVF2 Cantilevers

    Directory of Open Access Journals (Sweden)

    David F. Thompson

    2003-07-01

    Full Text Available The polymer piezoelectric polvinylidene fluoride has found widespread use in sensors and actuators. The bending mode of piezoelectricity offers very high sensitivities and low mechanical input impedance, but has not been studied in as much detail for sensor applications. We report the dynamic electromechanical properties of millimeter size cantilevers made from electroded films of PVF2. All devices tested had a single polymer layer. Several resonances are found below 1 kHz and the experimentally observed resonance frequency dependence on cantilever thickness and length are seen to agree well with published models which take the properties of the electrodes into account. It is found that bending resonances are also modulated by the width of the cantilever. Therefore, though the length and thickness control the resonance frequency most strongly, the actual realized value can be fine-tuned by changing cantilever width and the electrode material and its thickness. Further, all resonances display high piezoelectric coupling coefficients (keff, ranging between 0.2 - 0.35. The data presented here will be extremely useful in the design of sensors and actuators for a number of applications, since the combination of millimeter size scales and high piezoelectric sensitivities in the low audio range can be realized with this marriage of polymeric materials and cantilever geometries. Such an array of sensors can be used in cochlear implant applications, and when integrated with a resonance interrogation circuit can be used for the detection of low frequency vibrations of large structures. If appropriate mass/elasticity sensitive layers are coated on the electrodes, such a sensor can be used for the detection of a wide range of chemicals and biochemicals.

  5. Arch index and running biomechanics in children aged 10-14 years.

    Science.gov (United States)

    Hollander, Karsten; Stebbins, Julie; Albertsen, Inke Marie; Hamacher, Daniel; Babin, Kornelia; Hacke, Claudia; Zech, Astrid

    2018-03-01

    While altered foot arch characteristics (high or low) are frequently assumed to influence lower limb biomechanics and are suspected to be a contributing factor for injuries, the association between arch characteristics and lower limb running biomechanics in children is unclear. Therefore, the aim of this study was to investigate the relationship between a dynamically measured arch index and running biomechanics in healthy children. One hundred and one children aged 10-14 years were included in this study and underwent a biomechanical investigation. Plantar distribution (Novel, Emed) was used to determine the dynamic arch index and 3D motion capture (Vicon) to measure running biomechanics. Linear mixed models were established to determine the association between dynamic arch index and foot strike patterns, running kinematics, kinetics and temporal-spatial outcomes. No association was found between dynamic arch index and rate of rearfoot strikes (p = 0.072). Of all secondary outcomes, only the foot progression angle was associated with the dynamic arch index (p = 0.032) with greater external rotation in lower arched children. Overall, we found only few associations between arch characteristics and running biomechanics in children. However, altered foot arch characteristics are of clinical interest. Future studies should focus on detailed foot biomechanics and include clinically diagnosed high and low arched children. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Analysis of dynamic cantilever behavior in tapping mode atomic force microscopy.

    Science.gov (United States)

    Deng, Wenqi; Zhang, Guang-Ming; Murphy, Mark F; Lilley, Francis; Harvey, David M; Burton, David R

    2015-10-01

    Tapping mode atomic force microscopy (AFM) provides phase images in addition to height and amplitude images. Although the behavior of tapping mode AFM has been investigated using mathematical modeling, comprehensive understanding of the behavior of tapping mode AFM still poses a significant challenge to the AFM community, involving issues such as the correct interpretation of the phase images. In this paper, the cantilever's dynamic behavior in tapping mode AFM is studied through a three dimensional finite element method. The cantilever's dynamic displacement responses are firstly obtained via simulation under different tip-sample separations, and for different tip-sample interaction forces, such as elastic force, adhesion force, viscosity force, and the van der Waals force, which correspond to the cantilever's action upon various different representative computer-generated test samples. Simulated results show that the dynamic cantilever displacement response can be divided into three zones: a free vibration zone, a transition zone, and a contact vibration zone. Phase trajectory, phase shift, transition time, pseudo stable amplitude, and frequency changes are then analyzed from the dynamic displacement responses that are obtained. Finally, experiments are carried out on a real AFM system to support the findings of the simulations. © 2015 Wiley Periodicals, Inc.

  7. Photoionization cross-section for atomic orbitals with random and fixed spatial orientation

    International Nuclear Information System (INIS)

    Goldberg, S.M.; Fadley, C.S.; Kono, S.

    1981-01-01

    Atomic photoionization subshell cross-sections and asymmetry parameters necessary for determining the differential cross-sections of randomly-oriented atoms have been calculated within the one-electron, central-potential model and the dipole approximation for all subshells of C, O, Al, Si, S, Ni, Cu, Ga, Ge, As, Se, In, Sb, Cs, Ba, Ce, Ta, W, Pt, Au, and Pb for a photon energy range from 20 to 1500 eV, and the relevant Cooper minima located to within 10 eV. These values are tabulated for general use, together with the associated radial matrix elements and phase shifts. Differential photoionization cross-sections for fixed-orientation s-, p- and d-orbitals have also been derived within the same model for a completely general experimental geometry, and closed-form expressions depending on radial matrix elements and phase shifts are given. For the special geometry of a polarized excitation source with polarization parallel to the electron emission direction, it is further shown that such oriented-atom cross-sections are exactly proportional to the probability distribution of the initial orbital, a result equivalent to that derived by using a plane-wave final-state approximation. However, detailed numerical calculations of cross-sections for oriented Cu 3d and O 2p orbitals in various general geometries and at various energies exhibit significant differences in comparison to plane-wave cross-sections. By contrast, certain prior angular-resolved X-ray photoemission studies of single-crystal valence bands are found to have been carried out in an experimental geometry that fortuitously gave cross-sections close to the plane-wave predictions. (orig.)

  8. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  9. Piezoresistor-equipped fluorescence-based cantilever probe for near-field scanning.

    Science.gov (United States)

    Kan, Tetsuo; Matsumoto, Kiyoshi; Shimoyama, Isao

    2007-08-01

    Scanning near-field optical microscopes (SNOMs) with fluorescence-based probes are promising tools for evaluating the optical characteristics of nanoaperture devices used for biological investigations, and this article reports on the development of a microfabricated fluorescence-based SNOM probe with a piezoresistor. The piezoresistor was built into a two-legged root of a 160-microm-long cantilever. To improve the displacement sensitivity of the cantilever, the piezoresistor's doped area was shallowly formed on the cantilever surface. A fluorescent bead, 500 nm in diameter, was attached to the bottom of the cantilever end as a light-intensity-sensitive material in the visible-light range. The surface of the scanned sample was simply detected by the probe's end being displaced by contact with the sample. Measuring displacements piezoresistively is advantageous because it eliminates the noise arising from the use of the optical-lever method and is free of any disturbance in the absorption or the emission spectrum of the fluorescent material at the probe tip. The displacement sensitivity was estimated to be 6.1 x 10(-6) nm(-1), and the minimum measurable displacement was small enough for near-field measurement. This probe enabled clear scanning images of the light field near a 300 x 300 nm(2) aperture to be obtained in the near-field region where the tip-sample distance is much shorter than the light wavelength. This scanning result indicates that the piezoresistive way of tip-sample distance regulation is effective for characterizing nanoaperture optical devices.

  10. Arch translocation and the intra-arch elephant-trunk technique with collared graft for extended chronic dissecting aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ikenaga Shigeru

    2013-01-01

    Full Text Available Abstract Management of extensive, chronic, dissecting aortic aneurysms after prior repair of the ascending aorta presents a technical challenge for surgeons. A symptomatic 64-year-old patient was admitted for elective surgical repair of an aortic annular dilatation, causing severe aortic regurgitation, and a Crawford type II extended thoracoabdominal aneurysm, 4 years after he underwent primary repair of an acute aortic dissection. The aorta was diffusely dilated, and there were no sites beyond the distal aortic arch where anastomosis could be performed. We successfully performed total aortic replacement with a 2-stage strategy, using an arch translocation technique and an intra-arch elephant-trunk technique.

  11. Design and Simulation of A Novel Piezoelectric AlN-Si Cantilever Gyroscope

    Directory of Open Access Journals (Sweden)

    Jian Yang

    2018-02-01

    Full Text Available A novel design of piezoelectric aluminum nitride (AlN-Si composite cantilever gyroscope is proposed in this paper. The cantilever is stimulated to oscillate in plane by two inverse voltages which are applied on the two paralleled drive electrodes, respectively. The whole working principles are deduced, which based on the piezoelectric equation and elastic vibration equation. In this work, a cantilever gyroscope has been simulated and optimized by COMSOL Multiphysics 5.2a. The drive mode frequency is 87.422 kHz, and the sense mode frequency is 87.414 kHz. The theoretical sensitivity of this gyroscope is 0.145 pm/◦/s. This gyroscope has a small size and simple structure. It will be a better choice for the consumer electronics.

  12. Is there a prospect for hybrid aortic arch surgery?

    Science.gov (United States)

    Bashir, Mohamad; Harky, Amer; Bilal, Haris

    2018-05-16

    The surge of endovascular repair of aortic aneurysm in current modern aortic surgery practice has been the key for surgical management of elective cases of thoracic aortic aneurysms. This has paved way for the combined hybrid approach to be amongst the armamentarium for the management of aortic arch disease. The pivotal understanding of the aortic arch natural history coupled with device technology advancement allowed surgeons insight into delivery of hybrid surgery with acceptable morbidity and mortality results. This review article provides current insights into hybrid technique of aortic arch aneurysm repair and the evidences behind its applicability to arch surgery. It is aimed to highlight the challenges encountered for this innovative approach and correlate its challenges to those that are met by the conventional open aortic arch repair.

  13. Effect of Obesity on Arch Index in Young Adults

    Directory of Open Access Journals (Sweden)

    Sneha Sameer Ganu

    2013-01-01

    Full Text Available Background: Excessive increases in weight bearing forces caused by obesity may negatively affect the lower limbs and feet but minimal research has examined the long-term loading effects of obesity on the musculoskeletal system, particularly in reference to the feet. Objectives: The purpose of the study was to investigate the effect of obesity on medial longitudinal arch of foot in young adults. Method: 60 subjects, 30 obese & 30 non obese were assessed for height & weight using standard technique. Radiographic images under static condition were used for calculating the arch index. Result: The arch index of obese subjects was significantly lower than the non obese subjects & there is a negative correlation between the BMI & the arch index. Conclusion: These results suggests that obesity lowers the medial longitudinal arch of foot.

  14. System identification and control parameter optimization for a stylus profiler with exchangeable cantilevers

    Directory of Open Access Journals (Sweden)

    Felix Ströer

    2018-02-01

    Full Text Available Stylus instruments are widely used in production metrology due to their robustness. Interchangeable cantilevers allow a wide range of measuring tasks to be covered with one measuring device. When approaching the sample, the positioning of the stylus instrument tip relative to the measurement object has to be accomplished in a controlled way in order to prevent damages to the specimen and the stylus cantilever. This is achieved by a closed-loop control. We present a method for the objective description of the stylus cantilever dynamics with system-theoretical techniques and show a simple iterative approach to optimize closed-loop control parameters with boundary conditions.

  15. Evaluation of Maxillary Interpremolar, Molar Width by DRNA Indices and Arch Dimension, Arch Form in Maratha Population

    Directory of Open Access Journals (Sweden)

    Nitin Dungarwal

    2013-01-01

    Conclusion: Significant correlation was found between the sum of maxillary incisors and interpremolar width but not with the intermolar width while sum of mandibular incisors showed significant correlation with the interpremolar and intermolar arch width. There is no single arch form unique to any of the ethnic groups. A new formula is proposed to determine the premolar and molar index.

  16. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.

    Science.gov (United States)

    Uysal, Hakan; Kurtoglu, Cem; Gurbuz, Riza; Tutuncu, Naki

    2005-03-01

    The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72

  17. Nonlinear dynamic response of cantilever beam tip during atomic force microscopy (AFM) nanolithography of copper surface

    International Nuclear Information System (INIS)

    Yeh, Y-L; Jang, M-J; Wang, C-C; Lin, Y-P; Chen, K-S

    2008-01-01

    This paper investigates the nonlinear dynamic response of an atomic force microscope (AFM) cantilever beam tip during the nanolithography of a copper (Cu) surface using a high-depth feed. The dynamic motion of the tip is modeled using a combined approach based on Newton's law and empirical observations. The cutting force is determined from experimental observations of the piling height on the Cu surface and the rotation angle of the cantilever beam tip. It is found that the piling height increases linearly with the cantilever beam carrier velocity. Furthermore, the cantilever beam tip is found to execute a saw tooth motion. Both this motion and the shear cutting force are nonlinear. The elastic modulus in the y direction is variable. Finally, the velocity of the cantilever beam tip as it traverses the specimen surface has a discrete characteristic rather than a smooth, continuous profile

  18. SU-8 Cantilevers for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods

    Directory of Open Access Journals (Sweden)

    Anja Boisen

    2008-03-01

    Full Text Available Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We show examples of different integrated read-out methodsand their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity tochanges in the environmental temperature and pH of the buffer solution. Moreover, weshow that the SU-8 cantilever surface can be functionalised directly with receptormolecules for analyte detection, thereby avoiding gold-thiol chemistry.

  19. Track-Bridge Longitudinal Interaction of Continuous Welded Rails on Arch Bridge

    Directory of Open Access Journals (Sweden)

    Rong Chen

    2013-01-01

    Full Text Available Taking arch bridges, including deck, half-through, and through arch bridges (short for DAB, HTAB, and TAB as examples, mechanics analysis models of longitudinal interaction between continuously welded rails (short for CWRs and arch bridges are established. Based on the finite element method (FEM, the longitudinal interaction calculation software of CWR on arch bridges has been developed. Focusing on an HTAB, the tension, compression, and deflection conditions are calculated and analyzed. The results show that the mechanics analysis models of three types of arch bridges can truly reflect the real state of the structure; the calculation software can be used for systematic research of the CWR on arch bridge; as for HTAB, temperature difference of arch rib has a small effect on rail tension/compression, and arch bridge can be simplified as a continuous beam for rail tension/compression additional force calculation; in calculation of deflection conditions of HTAB, it is suggested that train loads are arranged on half span and full span and take the direction of load entering bridge into account. Additionally, the deflection additional force variation of CFST basket handle arch bridge is different from that of ordinary bridge.

  20. Bovine aortic arch: A novel association with thoracic aortic dilation

    International Nuclear Information System (INIS)

    Malone, C.D.; Urbania, T.H.; Crook, S.E.S.; Hope, M.D.

    2012-01-01

    Aim: To investigate whether there is a link between bovine arch and thoracic aortic aneurysm. Materials and methods: Computed tomography (CT) and magnetic resonance imaging (MRI) images of the thorax of 191 patients with dilated thoracic aortas and 391 consecutive, unselected patients as controls were retrospectively reviewed. Bovine arch was considered present if either a shared origin of the left common carotid and innominate arteries or an origin of the left common carotid from the innominate artery was identified. A chi-square test was used to evaluate the significance of differences between subgroups. Results: A trend towards increased prevalence of bovine arch was seen in patients with dilated aortas (26.2%) compared to controls (20.5%, p = 0.12). The association was statistically significant in patients over 70 years old (31.9%, p = 0.019) and when dilation involved the aortic arch (47.6%, p = 0.003). Conclusions: An association between bovine arch and aortic dilation is seen in older patients, and when dilation involves the aortic arch. Bovine arch should be considered a potential risk factor for thoracic aortic aneurysm.

  1. Fabrication and characterization of large arrays of mesoscopic gold rings on large-aspect-ratio cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Ngo, D. Q.; Petković, I., E-mail: ivana.petkovic@yale.edu; Lollo, A. [Department of Physics, Yale University, New Haven, Connecticut 06520 (United States); Castellanos-Beltran, M. A. [National Institute for Standards and Technology, Boulder, Colorado 80305 (United States); Harris, J. G. E. [Department of Physics, Yale University, New Haven, Connecticut 06520 (United States); Department of Applied Physics, Yale University, New Haven, Connecticut 06520 (United States)

    2014-10-15

    We have fabricated large arrays of mesoscopic metal rings on ultrasensitive cantilevers. The arrays are defined by electron beam lithography and contain up to 10{sup 5} rings. The rings have a circumference of 1 μm, and are made of ultrapure (6N) Au that is deposited onto a silicon-on-insulator wafer without an adhesion layer. Subsequent processing of the SOI wafer results in each array being supported at the end of a free-standing cantilever. To accommodate the large arrays while maintaining a low spring constant, the cantilevers are nearly 1 mm in both lateral dimensions and 100 nm thick. The extreme aspect ratio of the cantilevers, the large array size, and the absence of a sticking layer are intended to enable measurements of the rings' average persistent current in the presence of relatively small magnetic fields. We describe the motivation for these measurements, the fabrication of the devices, and the characterization of the cantilevers' mechanical properties. We also discuss the devices' expected performance in measurements of .

  2. Search for the optimally suited cantilever type for high-frequency MFM

    International Nuclear Information System (INIS)

    Koblischka, M R; Wei, J D; Kirsch, M; Lessel, M; Pfeifer, R; Brust, M; Hartmann, U; Richter, C; Sulzbach, T

    2007-01-01

    To optimize the performance of the high-frequency MFM (HF-MFM) technique [1-4], we performed a search for the best suited cantilever type and magnetic material coating. Using a HF-MFM setup with hard disk writer poles as test samples, we carried out HF-MFM imaging at frequencies up to 2 GHz. For HF-MFM, it is an essential ingredient that the tip material can follow the fast switching of the high-frequency fields. In this contribution, we investigated 6 different types of cantilevers (i) the 'standard' MFM tip (Nanoworld Pointprobe) with 30 nm CoCr coating, (ii) a 'SSS' (Nanoworld SuperSharpSilicon TM ) cantilever with a 10 nm CoCr coating, (iii) a (Ni, Zn)-ferrite coated pointprobe tip (iv) a Ba 3 Co 2 Fe 23 O 41 (BCFO) coated pointprobe tip, (v) a low-coercivity NiCo alloy coated tip, and (vi) a permalloy-coated tip

  3. A wall shear stress sensor using a pair of sidewall doped cantilevers

    Science.gov (United States)

    Nguyen, Thanh-Vinh; Kazama, Ryohei; Takahashi, Hidetoshi; Takahata, Tomoyuki; Matsumoto, Kiyoshi; Shimoyama, Isao

    2017-07-01

    In this paper, we report on a micro-electro mechanical system (MEMS)-based piezoresistive sensor for measuring shear stress induced by an airflow. The advantages of the proposed sensor include a simple sensing method and a high resonance frequency due to the small size of the sensing elements. Our sensor consists of a pair of 3 µm thick cantilevers with piezoresistors formed on the sidewall of their hinges to detect lateral deformation in the cantilevers induced by an airflow. Each cantilever has a 200 µm  ×  400 µm plate supported by two 150 µm long, 4 µm wide beams. The piezoresistors on the two cantilevers are designed to deform in opposite manners when a shear stress is applied and in the same manner when a pressure is applied. Therefore, the applied shear stress can be detected from the difference in the responses of the two cantilevers without becoming conflated with pressure. In this paper, the design, fabrication and evaluation of the proposed sensor are reported and compared to numerical simulation results. From the experimental results, the resolution of the sensor and its first resonance frequency are 1.3 Pa and 3.9 kHz, respectively. Moreover, we show that the effect of temperature on the readout of the sensor can be eliminated using a temperature-compensating piezoresistor fabricated on the same sensor chip. Finally, using the fabricated sensor, the measurement of the shear stress induced by an airflow with velocity between  -10 and 10 m s-1 is demonstrated.

  4. A wall shear stress sensor using a pair of sidewall doped cantilevers

    International Nuclear Information System (INIS)

    Nguyen, Thanh-Vinh; Shimoyama, Isao; Kazama, Ryohei; Takahashi, Hidetoshi; Takahata, Tomoyuki; Matsumoto, Kiyoshi

    2017-01-01

    In this paper, we report on a micro-electro mechanical system (MEMS)-based piezoresistive sensor for measuring shear stress induced by an airflow. The advantages of the proposed sensor include a simple sensing method and a high resonance frequency due to the small size of the sensing elements. Our sensor consists of a pair of 3 µ m thick cantilevers with piezoresistors formed on the sidewall of their hinges to detect lateral deformation in the cantilevers induced by an airflow. Each cantilever has a 200 µ m  ×  400 µ m plate supported by two 150 µ m long, 4 µ m wide beams. The piezoresistors on the two cantilevers are designed to deform in opposite manners when a shear stress is applied and in the same manner when a pressure is applied. Therefore, the applied shear stress can be detected from the difference in the responses of the two cantilevers without becoming conflated with pressure. In this paper, the design, fabrication and evaluation of the proposed sensor are reported and compared to numerical simulation results. From the experimental results, the resolution of the sensor and its first resonance frequency are 1.3 Pa and 3.9 kHz, respectively. Moreover, we show that the effect of temperature on the readout of the sensor can be eliminated using a temperature-compensating piezoresistor fabricated on the same sensor chip. Finally, using the fabricated sensor, the measurement of the shear stress induced by an airflow with velocity between  −10 and 10 m s −1 is demonstrated. (paper)

  5. Coexistence of bilateral first and second branchial arch anomalies

    Science.gov (United States)

    Thakur, J S; Shekar, Vidya; Saluja, Manika; Mohindroo, N K

    2013-01-01

    Branchial arch anomalies are one of the most common congenital anomalies that are usually unilateral and bilateral presentation is rare. The simultaneous presence of bilateral second branchial arch anomalies along with bilateral first arch anomalies is extremely rare, with only three such cases reported in the literature. We present two non-syndromic cases of coexisting bilateral first and second arch anomalies. Developmental anomalies of the branchial apparatus account for 17% of all paediatric cervical masses and are the most common type of congenital cervical mass. They usually present in the paediatric age group. About 96–97% of these anomalies are unilateral. Bilateral presentation is seen in 2–3% having a strong familial association. Congenital syndromes also have been associated with first and second branchial arch anomalies. Thorough clinical examination and investigations should be done to rule out these syndromes. PMID:23580675

  6. Arch-Axis Coefficient Optimization of Long-Span Deck-Type Concrete-Filled Steel Tubular Arch Bridge

    Science.gov (United States)

    Liu, Q. J.; Wan, S.; Liu, H. C.

    2017-11-01

    This paper is based on Nanpuxi super major bridge which is under construction and starts from Wencheng Zhejiang province to Taishun highway. A finite element model of the whole bridge is constructed using Midas Civil finite element software. The most adverse load combination in the specification is taken into consideration to determine the method of calculating the arch-axis coefficient of long-span deck-type concrete-filled steel tubular arch bridge. By doing this, this paper aims at providing references for similar engineering projects.

  7. Shielded piezoresistive cantilever probes for nanoscale topography and electrical imaging

    International Nuclear Information System (INIS)

    Yang, Yongliang; Ma, Eric Yue; Cui, Yong-Tao; Lai, Keji; Kundhikanjana, Worasom; Kelly, Michael; Shen, Zhi-Xun; Haemmerli, Alexandre; Harjee, Nahid; Pruitt, Beth L

    2014-01-01

    This paper presents the design and fabrication of piezoresistive cantilever probes for microwave impedance microscopy (MIM) to enable simultaneous topographic and electrical imaging. Plasma enhanced chemical vapor deposited Si 3 N 4  cantilevers with a shielded center conductor line and nanoscale conductive tip apex are batch fabricated on silicon-on-insulator wafers. Doped silicon piezoresistors are integrated at the root of the cantilevers to sense their deformation. The piezoresistive sensitivity is 2 nm for a bandwidth of 10 kHz, enabling topographical imaging with reasonable speed. The aluminum center conductor has a low resistance (less than 5 Ω) and small capacitance (∼1.7 pF) to ground; these parameters are critical for high sensitivity MIM imaging. High quality piezoresistive topography and MIM images are simultaneously obtained with the fabricated probes at ambient and cryogenic temperatures. These new piezoresistive probes remarkably broaden the horizon of MIM for scientific applications by operating with an integrated feedback mechanism at low temperature and for photosensitive samples. (paper)

  8. [A new method to orthodontically correct dental occlusal plane canting: wave-shaped arch].

    Science.gov (United States)

    Zheng, X; Hu, X X; Ma, N; Chen, X H

    2017-02-18

    To introduce a technique of second order wave-shaped arch wire to orthodontically treat dental occlusal plane canting (DOPC) with left-right interactive anchorage, and to test its clinical efficacy. Among the permanent dentition malocclusion patients who showed no obvious facial asymmetry, we screened for patients who showed anterior occlusal plane canting (AOPC) after routine orthodontic examination, treatment planning, MBT fixed appliance installation and serial arch wires alignment. Each patient had been clinically appraised in frontal view by 2 orthodontists and the patient him/herself; if all 3 agreed that the AOPC was obvious, the patient was included. By this means, we included 37 patients, including 10 males and 27 females; the average age was (21.9±5.2) years. To correct AOPC, opposite direction equal curvature second order rocking-chair curve was bent on each side of 0.46 mm×0.56 mm stainless steel edgewise wire. With reference to normal occlusal plane, a curve toward the occlusal surface was made to extrude under-erupted teeth on one side while a curve toward the gingiva was made to intrude over-erupted teeth on the other side, so that the arch wire was made into a wave shape in vertical dimension. Before and after application of wave-shaped arch wire, frontal facial photographs were taken when the patient's mouth was open slightly with lips retracted to show anterior occlusal plane (AOP) clearly. An AOP was constructed by connecting the center of the slot in the medial edge of canine bracket on each side in the photograph. The angles between the bipupillary plane(BPP) and the constructed AOP were measured in ImageJ1-48v software and the angle differences before and after treatment were compared with paired Wilcoxon test in SPSS 10.0 software. The wave-shaped arch could correct AOPC effectively in 3 to 10 months time with an average of 5.5±1.7 months; the angles between AOP and BBP before treatment ranged from 2.90° to 6.12° with a median of 4.01

  9. Monolithic Concrete vs Precast Concrete for the Construction of Bridge by Th Cantilever Method

    Directory of Open Access Journals (Sweden)

    Morlova Dumitru Daniel

    2015-07-01

    Full Text Available In the article "Monolithic Concrete vs Precast Concrete for the Construction of Bridges by the Cantilever Method", there are approached a number of issues that come out in the design and execution of prestressed concrete bridge structures using the cantilever method.

  10. Optimised cantilever biosensor with piezoresistive read-out

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Thaysen, J.; Hansen, Ole

    2003-01-01

    We present a cantilever-based biochemical sensor with piezoresistive read-out which has been optimised for measuring surface stress. The resistors and the electrical wiring on the chip are encapsulated in low-pressure chemical vapor deposition (LPCVD) silicon nitride, so that the chip is well sui...

  11. Monitoring system of arch bridge for safety network management

    Science.gov (United States)

    Joo, Bong Chul; Yoo, Young Jun; Lee, Chin Hyung; Park, Ki Tae; Hwang, Yoon Koog

    2010-03-01

    Korea has constructed the safety management network monitoring test systems for the civil infrastructure since 2006 which includes airport structure, irrigation structure, railroad structure, road structure, and underground structure. Bridges among the road structure include the various superstructure types which are Steel box girder bridge, suspension bridge, PSC-box-girder bridge, and arch bridge. This paper shows the process of constructing the real-time monitoring system for the arch bridge and the measured result by the system. The arch type among various superstructure types has not only the structural efficiency but the visual beauty, because the arch type superstructure makes full use of the feature of curve. The main measuring points of arch bridges composited by curved members make a difference to compare with the system of girder bridges composited by straight members. This paper also shows the method to construct the monitoring system that considers the characteristic of the arch bridge. The system now includes strain gauges and thermometers, and it will include various sensor types such as CCTV, accelerometers and so on additionally. For the long term and accuracy monitoring, the latest optical sensors and equipments are applied to the system.

  12. Developmental feature of the lumbosacral vertebral arch in childhood

    International Nuclear Information System (INIS)

    Yoshifuji, Kazuhisa; Morota, Nobuhito; Ihara, Satoshi

    2007-01-01

    We investigated a developmental feature of the lumbosacral vertebral arch in childhood that has rarely been reported previously. Sixty-seven patients underwent functional posterior rhizotomy from September 2000 to June 2006 at National Center for Child Health and Development. Sixty of these patients, who had no deformity in their lumbosacral spine, were included in this study and their Computed Tomography (CT) images were analyzed retrospectively. There were 36 boys and 24 girls, aged from 2-12 years. The rate and mean number of non-union vertebral arches between L1 and S3 were 78.3% (95% CI, 65.8-87.9%) and 1.7 (standard deviation (SD), 1.3). The non-union arch was most frequently found at the S1 level, and was more significantly observed in the younger age group (2-5 years of age). The S4 and S5 arches, which often remained open as the sacral hiatus, were constantly open in childhood. This study demonstrates that the vertebral arches of the lumbosacral spine in normal development are often not fused during childhood. It is important to differentiate normal non-union arches from pathological spina bifida. (author)

  13. Three-axis magnetic field induction sensor realized on buckled cantilever plate

    KAUST Repository

    Alfadhel, Ahmed; Carreno, Armando Arpys Arevalo; Foulds, Ian G.; Kosel, Jü rgen

    2013-01-01

    This work presents the fabrication and characterization of a three-axis induction sensor consisting of one planar microcoil, fixed on the substrate, and two microcoils fabricated on Bbuckled cantilever plates (BCP) oriented perpendicularly to the substrate and each other. The BCP allows an out-of-plane translation while preserving a direct connection to the substrate, which aids the routing of electrical lines. The fabricated sensor is integrated on a single substrate, allowing interaction and integration with other systems. The devices are fabricated using a MEMS polymer fabrication process. Different microcoil configurations are realized with 17-30 turns, 5 μm track width, and 15-20 μm track pitch. The sensor showed up to 6.8 nT/√Hz resolution to magnetic fields within a frequency range of 40 Hz to 1 MHz. The BCP concept provides a strikingly simple method to fabricate a three-axis field sensor that can readily be integrated with electronic circuits, and the sensor's performance can easily be adjusted within a wide range by changing the dimensions of the coils. © 2013 IEEE.

  14. Three-axis magnetic field induction sensor realized on buckled cantilever plate

    KAUST Repository

    Alfadhel, Ahmed

    2013-07-01

    This work presents the fabrication and characterization of a three-axis induction sensor consisting of one planar microcoil, fixed on the substrate, and two microcoils fabricated on Bbuckled cantilever plates (BCP) oriented perpendicularly to the substrate and each other. The BCP allows an out-of-plane translation while preserving a direct connection to the substrate, which aids the routing of electrical lines. The fabricated sensor is integrated on a single substrate, allowing interaction and integration with other systems. The devices are fabricated using a MEMS polymer fabrication process. Different microcoil configurations are realized with 17-30 turns, 5 μm track width, and 15-20 μm track pitch. The sensor showed up to 6.8 nT/√Hz resolution to magnetic fields within a frequency range of 40 Hz to 1 MHz. The BCP concept provides a strikingly simple method to fabricate a three-axis field sensor that can readily be integrated with electronic circuits, and the sensor\\'s performance can easily be adjusted within a wide range by changing the dimensions of the coils. © 2013 IEEE.

  15. Maxillary arch rehabilitation using implant-supported computer-assisted design-computer-assisted manufacturing-milled titanium framework

    Directory of Open Access Journals (Sweden)

    Tulika S Khanna

    2017-01-01

    Full Text Available Esthetic and functional rehabilitation of completely edentulous maxillary arch with fixed implant supported prosthesis is a challenging task. Newer technologies such as computer assisted design computer assisted manufacturing (CAD CAM and cone beam conventional tomography play an important role in achieving predictable results. Full mouth porcelain fused to metal (PFM individual crowns on CAD CAM milled titanium framework provides positive esthetic and functional outcome. This is a case report of rehabilitation of partially edentulous maxillary arch patient. Staged rehabilitation of this patient was planned. In the first stage, root canal treatment of key abutment teeth was done, nonsalvageable teeth were removed, and immediate interim overdenture was provided. In the second stage, five Nobel Biocare dental implants were placed. After integration impressions were made, CAD CAM milled titanium bar was fabricated. Individual PFM crowns were made and cemented. This method gives better esthetic compared to acrylic fused to metal hybrid prosthesis with the advantage of retrievability just like screw retained prosthesis. Hence, this technique is good for rehabilitation of patients with high esthetic demands.

  16. Environmental sensors based on micromachined cantilevers with integrated read-out

    DEFF Research Database (Denmark)

    Boisen, Anja; Thaysen, Jacob; Jensenius, Henriette

    2000-01-01

    -out facilitates measurements in liquid. The probe has been successfully implemented in gaseous as well as in liquid experiments. For example, the probe has been used as an accurate and minute thermal sensor and as a humidity sensor. In liquid, the probe has been used to detect the presence of alcohol in water. (C......An AFM probe with integrated piezoresistive read-out has been developed and applied as a cantilever-based environmental sensor. The probe has a built-in reference cantilever, which makes it possible to subtract background drift directly in the measurement. Moreover, the integrated read...

  17. Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2015-01-01

    Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.

  18. Mechanics Evolution Characteristics Analysis of Pressure-arch in Fully-mechanized Mining Field

    Directory of Open Access Journals (Sweden)

    S.R. Wang

    2014-09-01

    Full Text Available Based on a practical engineering, the three-dimension computational model was built using FLAC3D under the fullymechanized mining condition. Considering four variation factors, such as the distance of mining advancing, the strength of the surrounding rock, the speed of mining advancing and the dip angle of the coal seam, the mechanics evolution characteristics of the pressure-arch were analyzed. The result showed that for the horizontal seam, the geometric shape of the pressure-arch varied from flat arch to round arch gradually and the height and thickness of the pressure-arch also increased; the maximum principal stress in the skewback also increased with the working face advancing. With the strength of the surrounding rock from soft to hard, the arch thickness reduced, and the arch loading decreased. To improve the mining speed can do some contributions to the stability of the pressure-arch in the mining field. With the increase of dip angle of the seam, the pressure-arch displayed an asymmetric shape, the vault was tilted and moved to the upward direction. At the same time, the thickness of the pressure-arch increased, and the stress concentration in the skewback tended to be further intensified.

  19. Analysis the effect of different geometries of AFM's cantilever on the dynamic behavior and the critical forces of three-dimensional manipulation

    International Nuclear Information System (INIS)

    Korayem, Moharam Habibnejad; Saraie, Maniya B.; Saraee, Mahdieh B.

    2017-01-01

    An important challenge when using an atomic force microscope (AFM) is to be able to control the force exerted by the AFM for performing various tasks. Nevertheless, the exerted force is proportional to the deflection of the AFM cantilever, which itself is affected by a cantilever's stiffness coefficient. Many papers have been published so far on the methods of obtaining the stiffness coefficients of AFM cantilevers in 2D; however, a comprehensive model is yet to be presented on 3D cantilever motion. The discrepancies between the equations of the 2D and 3D analysis are due to the number and direction of forces and moments that are applied to a cantilever. Moreover, in the 3D analysis, contrary to the 2D analysis, due to the interaction between the forces and moments applied on a cantilever, its stiffness values cannot be separately expressed for each direction; and instead, a stiffness matrix should be used to correctly derive the relevant equations. In this paper, 3D stiffness coefficient matrices have been obtained for three common cantilever geometries including the rectangular, V-shape and dagger-shape cantilevers. The obtained equations are validated by two methods. In the first approach, the Finite Element Method is combined with the cantilever deflection values computed by using the obtained stiffness matrices. In the second approach, by reducing the problem's parameters, the forces applied on a cantilever along different directions are compared with each other in 2D and 3D cases. Then the 3D manipulation of a stiff nanoparticle is modeled and simulated by using the stiffness matrices obtained for the three cantilever geometries. The obtained results indicate that during the manipulation process, the dagger-shaped and rectangular cantilevers exert the maximum and minimum amounts of forces on the stiff nanoparticle, respectively. Also, by examining the effects of different probe tip geometries, it is realized that a probe tip of cylindrical geometry exerts the

  20. An Experimental and Theoretical Investigation of Electrostatically Coupled Cantilever Microbeams

    KAUST Repository

    Ilyas, Saad

    2016-06-16

    We present an experimental and theoretical investigation of the static and dynamic behavior of electrostatically coupled laterally actuated silicon microbeams. The coupled beam resonators are composed of two almost identical flexible cantilever beams forming the two sides of a capacitor. The experimental and theoretical analysis of the coupled system is carried out and compared against the results of beams actuated with fixed electrodes individually. The pull-in characteristics of the electrostatically coupled beams are studied, including the pull-in time. The dynamics of the coupled dual beams are explored via frequency sweeps around the neighborhood of the natural frequencies of the system for different input voltages. Good agreement is reported among the simulation results and the experimental data. The results show considerable drop in the pull-in values as compared to single microbeam resonators. The dynamics of the coupled beam resonators are demonstrated as a way to increase the bandwidth of the resonator near primary resonance as well as a way to introduce increased frequency shift, which can be promising for resonant sensing applications. Moreover the dynamic pull-in characteristics are also studied and proposed as a way to sense the shift in resonance frequency.

  1. Investigations on antibody binding to a micro-cantilever coated with a BAM pesticide residue

    DEFF Research Database (Denmark)

    Bache, Michael; Taboryski, Rafael Jozef; Schmid, Silvan

    2011-01-01

    -BAM antibody is measured using the CantiLab4© system from Cantion A/S with four gold-coated cantilevers and piezo resistive readout. The detection mechanism is in principle label-free, but fluorescent-marked antibodies have been used to subsequently verify the binding on the cantilever surface. The bending...

  2. Digital models: How can dental arch form be verified chairside?

    Directory of Open Access Journals (Sweden)

    Alana Tavares

    Full Text Available ABSTRACT Introduction: Plaster dental casts are routinely used during clinical practice to access maxillary dental arch form and assist on fabrication of individualized orthodontic archwires. Recently introduced, digital model technology may offer a limitation for the obtainment of a dental physical record. In this context, a tool for dental arch form assessment for chairside use is necessary when employing digital models. In this regard, paper print of the dental arch seems thus to be useful. Methods: In the present study, 37 lower arch models were used. Intercanine and intermolar widths and dental arch length measurements were performed and compared using plaster dental casts, digital models and paper print image of the models. Ortho Insight 3D scanner was employed for model digitalization. Results: No statistically significant differences were noted regarding the measurements performed on the plaster or digital models (p> 0.05. Paper print images, however, showed subestimated values for intercanine and intermolar widths and overestimated values for dental arch length. Despite being statistically significant (p< 0.001, the differences were considered clinically negligible. Conclusion: The present study suggests that paper print images obtained from digital models are clinically accurate and can be used as a tool for dental arch form assessment for fabrication of individualized orthodontic archwires.

  3. Digital models: How can dental arch form be verified chairside?

    Science.gov (United States)

    Tavares, Alana; Braga, Emanuel; de Araújo, Telma Martins

    2017-01-01

    ABSTRACT Introduction: Plaster dental casts are routinely used during clinical practice to access maxillary dental arch form and assist on fabrication of individualized orthodontic archwires. Recently introduced, digital model technology may offer a limitation for the obtainment of a dental physical record. In this context, a tool for dental arch form assessment for chairside use is necessary when employing digital models. In this regard, paper print of the dental arch seems thus to be useful. Methods: In the present study, 37 lower arch models were used. Intercanine and intermolar widths and dental arch length measurements were performed and compared using plaster dental casts, digital models and paper print image of the models. Ortho Insight 3D scanner was employed for model digitalization. Results: No statistically significant differences were noted regarding the measurements performed on the plaster or digital models (p> 0.05). Paper print images, however, showed subestimated values for intercanine and intermolar widths and overestimated values for dental arch length. Despite being statistically significant (p< 0.001), the differences were considered clinically negligible. Conclusion: The present study suggests that paper print images obtained from digital models are clinically accurate and can be used as a tool for dental arch form assessment for fabrication of individualized orthodontic archwires. PMID:29364382

  4. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  5. Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.

    Science.gov (United States)

    Sader, John E; Lu, Jianing; Mulvaney, Paul

    2014-11-01

    Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, whose shapes vary considerably, and experimentally verify these results. The dynamic-to-static optical lever sensitivity ratio is found to range from 1.09 to 1.41 for the cantilevers studied - in stark contrast to the constant value of 1.09 used widely in current calibration studies. This analysis shows that accuracy of the thermal noise method for the static spring constant is strongly dependent on cantilever geometry - neglect of these dynamic-to-static factors can induce errors exceeding 100%. We also discuss a simple experimental approach to non-invasively and simultaneously determine the dynamic and static spring constants and optical lever sensitivities of cantilevers of arbitrary shape, which is applicable to all AFM platforms that have the thermal noise method for spring constant calibration.

  6. Super-light pearl-chain arch vaults

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Halding, Philip Skov

    2014-01-01

    Arch vaults are known as optimal and impressive structures, but due to their curved shapes they are extremely costly to produce in countries, where the cost of labor is high. By means of super-light pearl-chain technology arch vaults can be constructed from equal plane prefabricated elements, which...... that it is also applicable as basic elements for super-light pearl-chain vaults. Machines and software have been developed for automatic mass production of the elements, and the first factory has started production in Denmark in 2014 delivering SL-deck elements for a variety of building projects. This means...... is known from curved voluminous elements. The paper describes the first full-scale test of an arch vault made of SL-deck elements demonstrating the principle, documenting the load-bearing capacity, and solving a number of details needed in order to create vaults in practice. Considerations and plans...

  7. Plastic collapse load of crown-hinged steel circular arches : a theoretical method

    NARCIS (Netherlands)

    Spoorenberg, R.C.; Snijder, H.H.; Hoenderkamp, J.C.D.

    2013-01-01

    For construction purposes and to avoid detrimental influences of foundation settlements arches are not always made from a single arch-rib but are built by connecting two curvilinear elements at the crown with a hinge. These arches are also known as crown-hinged arches. This paper presents an

  8. A geometric parameter study of piezoelectric coverage on a rectangular cantilever energy harvester

    International Nuclear Information System (INIS)

    Patel, R; McWilliam, S; Popov, A A

    2011-01-01

    This paper proposes a versatile model for optimizing the performance of a rectangular cantilever beam piezoelectric energy harvester used to convert ambient vibrations into electrical energy. The developed model accounts for geometric changes to the natural frequencies, mode shapes and damping in the structure. This is achieved through the combination of finite element modelling and a distributed parameter electromechanical model, including load resistor and charging capacitor models. The model has the potential for use in investigating the influence of numerous geometric changes on harvester performance, and incorporates a model for accounting for changes in damping as the geometry changes. The model is used to investigate the effects of substrate and piezoelectric layer length, and piezoelectric layer thickness on the performance of a microscale device. Findings from a parameter study indicate the existence of an optimum sample length due to increased mechanical damping for longer beams and improved power output using thicker piezoelectric layers. In practice, harvester design is normally based around a fixed operating frequency for a particular application, and improved performance is often achieved by operating at or near resonance. To achieve unbiased comparisons between different harvester designs, parameter studies are performed by changing multiple parameters simultaneously with the natural frequency held fixed. Performance enhancements were observed using shorter piezoelectric layers as compared to the conventional design, in which the piezoelectric layer and substrate are of equal length

  9. Agenesis of the posterior arch of the atlas

    Directory of Open Access Journals (Sweden)

    Torriani Martin

    2002-01-01

    Full Text Available PURPOSE: To illustrate the radiological findings and review the current literature concerning a rare congenital abnormality of the posterior arch of the atlas. CASE REPORT: An adult female without neurological symptoms presented with an absent posterior arch of the atlas, examined with plain films and helical computerized tomography. Complete agenesis of the posterior arch of the atlas is a rare entity that can be easily identified by means of plain films. Although it is generally asymptomatic, atlantoaxial instability and neurological deficits may occur because of structural instability. Computerized tomography provides a means of assessing the extent of this abnormality and can help evaluate the integrity of neural structures. Although considered to be rare entities, defects of the posterior arch of the atlas may be discovered as incidental asymptomatic findings in routine cervical radiographs. Familiarity with this abnormality may aid medical professionals in the correct management of these cases.

  10. Asymmetric resonance frequency analysis of in-plane electrothermal silicon cantilevers for nanoparticle sensors

    Science.gov (United States)

    Bertke, Maik; Hamdana, Gerry; Wu, Wenze; Marks, Markus; Suryo Wasisto, Hutomo; Peiner, Erwin

    2016-10-01

    The asymmetric resonance frequency analysis of silicon cantilevers for a low-cost wearable airborne nanoparticle detector (Cantor) is described in this paper. The cantilevers, which are operated in the fundamental in-plane resonance mode, are used as a mass-sensitive microbalance. They are manufactured out of bulk silicon, containing a full piezoresistive Wheatstone bridge and an integrated thermal heater for reading the measurement output signal and stimulating the in-plane excitation, respectively. To optimize the sensor performance, cantilevers with different cantilever geometries are designed, fabricated and characterized. Besides the resonance frequency, the quality factor (Q) of the resonance curve has a high influence concerning the sensor sensitivity. Because of an asymmetric resonance behaviour, a novel fitting function and method to extract the Q is created, different from that of the simple harmonic oscillator (SHO). For testing the sensor in a long-term frequency analysis, a phase- locked loop (PLL) circuit is employed, yielding a frequency stability of up to 0.753 Hz at an Allan variance of 3.77 × 10-6. This proposed asymmetric resonance frequency analysis method is expected to be further used in the process development of the next-generation Cantor.

  11. Asymmetric resonance frequency analysis of in-plane electrothermal silicon cantilevers for nanoparticle sensors

    International Nuclear Information System (INIS)

    Bertke, Maik; Hamdana, Gerry; Wu, Wenze; Marks, Markus; Wasisto, Hutomo Suryo; Peiner, Erwin

    2016-01-01

    The asymmetric resonance frequency analysis of silicon cantilevers for a low-cost wearable airborne nanoparticle detector (Cantor) is described in this paper. The cantilevers, which are operated in the fundamental in-plane resonance mode, are used as a mass-sensitive microbalance. They are manufactured out of bulk silicon, containing a full piezoresistive Wheatstone bridge and an integrated thermal heater for reading the measurement output signal and stimulating the in-plane excitation, respectively. To optimize the sensor performance, cantilevers with different cantilever geometries are designed, fabricated and characterized. Besides the resonance frequency, the quality factor ( Q ) of the resonance curve has a high influence concerning the sensor sensitivity. Because of an asymmetric resonance behaviour, a novel fitting function and method to extract the Q is created, different from that of the simple harmonic oscillator (SHO). For testing the sensor in a long-term frequency analysis, a phase- locked loop (PLL) circuit is employed, yielding a frequency stability of up to 0.753 Hz at an Allan variance of 3.77 × 10 -6 . This proposed asymmetric resonance frequency analysis method is expected to be further used in the process development of the next-generation Cantor. (paper)

  12. Correction of complete maxillary crossbite with severe crowding using Hyrax expansion and fixed appliance.

    Science.gov (United States)

    Wangsrimongkol, Tasanee; Manosudprasit, Montian; Pisek, Poonsak; Leelasinjaroen, Pornnapha

    2013-09-01

    An 18-year-old Thai man who presented with a secondary cleft palate, maxillary hypoplasia and severe crowding was treated by rapid maxillary expansion and fixed orthodontic appliances. Initial assessment found skeletal Class III malrelationship and dental Class II malocclusion with anterior and bilateral posterior crossbites. Camouflage orthodontic treatment was planned using a rapid maxillary expansion appliance and correcting crowding with extraction all four premolar teeth. A Hyrax appliance and vertical loop arch wire were placed for maxillary arch expansion of 9.5 mms at first molars and canines, and 5.5 mms at the premolars and obtained positive overjet. Both acceptable skeletal and soft tissue relationships and satisfactory occlusion were produced. After 14 months of postoperative follow-up, the occlusal result was stable and no skeletal reversals could be detected.

  13. Modified protrusion arch for anterior crossbite correction - a case report.

    Science.gov (United States)

    Roy, Abhishek Singha; Singh, Gulshan Kr; Tandon, Pradeep; Chaudhary, Ramsukh

    2013-01-01

    Borderline and mild skeletal Class III relationships in adult patients are usually treated by orthodontic camouflage. Reasonably rood results have been achieved with nonsurgical teatment of anterior crossbite. Class III malocclusion may be associated with mandibular prognathism, maxillary retrognathism, or both. Class III maxillary retrognathism generally involves anterior crossbite, which must be opened if upper labial brackets are to be bonded. If multiple teeth are in crossbite, after opening the bite usual step is to ligate forward or advancement arch made of 0.018" or 0.020" stainless steel or NiTi wire main arch that must be kept separated 2 mm from the slot ofupper incisor braces. Two stops or omegas are made 1 mm mesial to the tubes of the molar bands that will impede main arch from slipping,and in this manner the arch will push the anterior teeth forward Here we have fabricated a modified multiple loop protrusion arch to correct an anterior crossbite with severe crowding that was not amenable to correct by advancement arches.

  14. Structure–performance relationships for cantilever-type piezoelectric energy harvesters

    International Nuclear Information System (INIS)

    Cho, Kyung-Hoon; Park, Hwi-Yeol; Heo, Jin S.; Priya, Shashank

    2014-01-01

    This study provides comprehensive analysis of the structure–performance relationships in cantilever-type piezoelectric energy harvesters. It provides full understanding of the effect of all the practical global control variables on the harvester performance. The control variables considered for the analysis were material parameters, areal and volumetric dimensions, and configuration of the inactive and active layers. Experimentally, the output power density of the harvester was maximum when the shape of the beam was close to a square for a constant bending stiffness and a fixed beam area. Through analytical modeling of the effective stiffness for the piezoelectric bimorph, the conditions for enhancing the bending stiffness within the same beam volume as that of a conventional bimorph were identified. The harvester configuration with beam aspect ratio of 0.86 utilizing distributed inactive layers exhibited an giant output power of 52.5 mW and power density of 28.5 mW cm −3 at 30 Hz under 6.9 m s −2 excitation. The analysis further indicates that the trend in the output power with varying damping ratio is dissimilar to that of the efficiency. In order to realize best performance, the harvester should be designed with respect to maximizing the magnitude of output power.

  15. SU-8 Cantilevers for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods

    OpenAIRE

    Anja Boisen; Mogens Havsteen-Jakobsen; Gabriela Blagoi; Daniel Haefliger; Søren Dohn; Alicia Johansson; Michael Lillemose; Stephan Keller; Maria Nordström

    2008-01-01

    Here, we present the activities within our research group over the last five years with cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interesting polymer for fabrication of cantilevers for bio/chemical sensing due to its simple processing and low Young's modulus. We show examples of different integrated read-out methods and their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity to changes in the environmental temperature and pH of the bu...

  16. A Meta-Analysis of Total Arch Replacement With Frozen Elephant Trunk in Acute Type A Aortic Dissection.

    Science.gov (United States)

    Takagi, Hisato; Umemoto, Takuya

    2016-01-01

    To assess the safety and efficacy, we performed a meta-analysis of total arch replacement with frozen elephant trunk in exclusive acute type A (neither chronic nor type B) aortic dissection. Databases including MEDLINE and EMBASE were searched through March 2015 using Web-based search engines (PubMed and OVID). Eligible studies were case series of frozen elephant trunk enrolling patients with acute type A (neither chronic nor type B) aortic dissection reporting at least early (in-hospital or 30-day) all-cause mortality. Study-specific estimates were combined in both fixed- and random-effect models. Fifteen studies enrolling 1279 patients were identified and included. Pooled analyses demonstrated the cardiopulmonary bypass time of 207.1 (95% confidence interval [CI], 186.1-228.1) minutes, aortic cross-clamp time of 123.3 (95% CI, 113.1-133.5) minutes, selective antegrade cerebral perfusion time of 49.3 (95% CI, 37.6-61.0) minutes, hypothermic circulatory arrest time of 39.0 (95% CI, 30.7-47.2) minutes, early mortality of 9.2% (95% CI, 7.7-11.0%), stroke of 4.8% (95% CI, 2.5-9.0%), spinal cord injury of 3.5% (95% CI, 1.9-6.6%), mid- to long-term (≥1-year) overall mortality of 13.0% (95% CI, 10.4-16.0%), reintervention of 9.6% (95% CI, 5.6-15.8%), and false lumen thrombosis of 96.8% (95% CI, 90.7-98.9%). Total arch replacement with frozen elephant trunk provides a safe alternative to that with conventional elephant trunk in patients with acute type A aortic dissection, with acceptable early mortality and morbidity. The rates of mid- to long-term reintervention and false lumen non-thrombosis may be lower in patients undergoing the frozen than conventional elephant trunk procedure. © The Author(s) 2016.

  17. Integrated cantilever-based flow sensors with tunable sensitivity for in-line monitoring of flow fluctuations in microfluidic systems

    DEFF Research Database (Denmark)

    Noeth, Nadine-Nicole; Keller, Stephan Sylvest; Boisen, Anja

    2014-01-01

    For devices such as bio-/chemical sensors in microfluidic systems, flow fluctuations result in noise in the sensor output. Here, we demonstrate in-line monitoring of flow fluctuations with a cantilever-like sensor integrated in a microfluidic channel. The cantilevers are fabricated in different...... is directly proportional to the flow rate fluctuations in the microfluidic channel. The SiN cantilevers show a detection limit below 1 nL/min and the thinnest SU-8 cantilevers a detection limit below 5 nL/min. Finally, the sensor is applied for in-line monitoring of flow fluctuations generated by external...

  18. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  19. Dynamic characterization of small fibers based on the flexural vibrations of a piezoelectric cantilever probe

    International Nuclear Information System (INIS)

    Zhang, Xiaofei; Ye, Xuan; Li, Xide

    2016-01-01

    In this paper, we present a cantilever-probe system excited by a piezoelectric actuator, and use it to measure the dynamic mechanical properties of a micro- and nanoscale fiber. Coupling the fiber to the free end of the cantilever probe, we found the dynamic stiffness and damping coefficient of the fiber from the resonance frequency and the quality factor of the fiber-cantilever-probe system. The properties of Bacillus subtilis fibers measured using our proposed system agreed with tensile measurements, validating our method. Our measurements show that the piezoelectric actuator coupled to cantilever probe can be made equivalent to a clamped cantilever with an effective length, and calculated results show that the errors of measured natural frequency of the system can be ignored if the coupled fiber has an inclination angle of alignment of less than 10°. A sensitivity analysis indicates that the first or second resonant mode is the sensitive mode to test the sample’s dynamic stiffness, while the damping property has different sensitivities for the first four modes. Our theoretical analysis demonstrates that the double-cantilever probe is also an effective sensitive structure that can be used to perform dynamic loading and characterize dynamic response. Our method has the advantage of using amplitude-frequency curves to obtain the dynamic mechanical properties without directly measuring displacements and forces as in tensile tests, and it also avoids the effects of the complex surface structure and deformation presenting in contact resonance method. Our method is effective for measuring the dynamic mechanical properties of fiber-like one-dimensional (1D) materials. (paper)

  20. Dynamic characterization of small fibers based on the flexural vibrations of a piezoelectric cantilever probe

    Science.gov (United States)

    Zhang, Xiaofei; Ye, Xuan; Li, Xide

    2016-08-01

    In this paper, we present a cantilever-probe system excited by a piezoelectric actuator, and use it to measure the dynamic mechanical properties of a micro- and nanoscale fiber. Coupling the fiber to the free end of the cantilever probe, we found the dynamic stiffness and damping coefficient of the fiber from the resonance frequency and the quality factor of the fiber-cantilever-probe system. The properties of Bacillus subtilis fibers measured using our proposed system agreed with tensile measurements, validating our method. Our measurements show that the piezoelectric actuator coupled to cantilever probe can be made equivalent to a clamped cantilever with an effective length, and calculated results show that the errors of measured natural frequency of the system can be ignored if the coupled fiber has an inclination angle of alignment of less than 10°. A sensitivity analysis indicates that the first or second resonant mode is the sensitive mode to test the sample’s dynamic stiffness, while the damping property has different sensitivities for the first four modes. Our theoretical analysis demonstrates that the double-cantilever probe is also an effective sensitive structure that can be used to perform dynamic loading and characterize dynamic response. Our method has the advantage of using amplitude-frequency curves to obtain the dynamic mechanical properties without directly measuring displacements and forces as in tensile tests, and it also avoids the effects of the complex surface structure and deformation presenting in contact resonance method. Our method is effective for measuring the dynamic mechanical properties of fiber-like one-dimensional (1D) materials.

  1. Investigation of static and dynamic behavior of functionally graded piezoelectric actuated Poly-Si micro cantilever probe

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Vibhuti Bhushan; Parashar, Sandeep Kumar, E-mail: skparashar@rtu.ac.in [Department of Mechanical Engineering, Rajasthan Technical University, Kota (India)

    2016-04-13

    In the present paper a novel functionally graded piezoelectric (FGP) actuated Poly-Si micro cantilever probe is proposed for atomic force microscope. The shear piezoelectric coefficient d{sub 15} has much higher value than coupling coefficients d{sub 31} and d{sub 33}, hence in the present work the micro cantilever beam actuated by d{sub 15} effect is utilized. The material properties are graded in the thickness direction of actuator by a simple power law. A three dimensional finite element analysis has been performed using COMSOL Multiphysics® (version 4.2) software. Tip deflection and free vibration analysis for the micro cantilever probe has been done. The results presented in the paper shall be useful in the design of micro cantilever probe and their subsequent utilization in atomic force microscopes.

  2. Discussion of the Improved Methods for Analyzing a Cantilever Beam Carrying a Tip-Mass under Base Excitation

    Directory of Open Access Journals (Sweden)

    Wang Hongjin

    2014-01-01

    Full Text Available Two improved analytical methods of calculations for natural frequencies and mode shapes of a uniform cantilever beam carrying a tip-mass under base excitation are presented based on forced vibration theory and the method of separation of variables, respectively. The cantilever model is simplified in detail by replacing the tip-mass with an equivalent inertial force and inertial moment acting at the free end of the cantilever based on D’Alembert’s principle. The concentrated equivalent inertial force and inertial moment are further represented as distributed loads using Dirac Delta Function. In this case, some typical natural frequencies and mode shapes of the cantilever model are calculated by the improved and unimproved analytical methods. The comparing results show that, after improvement, these two methods are in extremely good agreement with each other even the offset distance between the gravity center of the tip-mass and the attachment point is large. As further verification, the transient and steady displacement responses of the cantilever system under a sine base excitation are presented in which two improved methods are separately utilized. Finally, an experimental cantilever system is fabricated and the theoretical displacement responses are validated by the experimental measurements successfully.

  3. AFM cantilever with in situ renewable mercury microelectrode

    NARCIS (Netherlands)

    Schön, Peter Manfred; Geerlings, J.; Tas, Niels Roelof; Sarajlic, Edin

    2013-01-01

    We report here first results obtained on a novel, in situ renewable mercury microelectrode integrated into an atomic force microscopy (AFM) cantilever. Our approach is based on a fountain pen probe with appropriate dimensions enabling reversible filling with(nonwetting) mercury under changing the

  4. Variable RF capacitor based on a-Si:H (P-doped) multi-length cantilevers

    International Nuclear Information System (INIS)

    Fu, Y Q; Milne, S B; Luo, J K; Flewitt, A J; Wang, L; Miao, J M; Milne, W I

    2006-01-01

    A variable RF capacitor with a-Si:H (doped with phosphine) cantilevers as the top electrode were designed and fabricated. Because the top multi-cantilever electrodes have different lengths, increasing the applied voltage pulled down the cantilever beams sequentially, thus realizing a gradual increase of the capacitance with the applied voltage. A high-k material, H f O 2 , was used as an insulating layer to increase the tuning range of the capacitance. The measured capacitance from the fabricated capacitor was much lower and the pull-in voltage was much higher than those from theoretical analysis because of incomplete contact of the two electrodes, existence of film differential stresses and charge injection effect. Increase of sweeping voltage rate could significantly shift the pull-in voltage to higher values due to the charge injection mechanisms

  5. Tilted Implants for Full-Arch Rehabilitations in Completely Edentulous Maxilla: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Nicolò Cavalli

    2012-01-01

    Full Text Available Purpose. The aims of this study were to assess the treatment outcome of immediately loaded full-arch fixed bridges anchored to both tilted and axially placed implants in the edentulous maxilla and to evaluate the incidence of biological and prosthetic complications. Materials and Methods. Thirty-four patients (18 women and 16 men were included in the study. Each patient received a maxillary full-arch fixed bridge supported by two axial implants and two distal tilted implants. A total of 136 implants were inserted. Loading was applied within 48 hours of surgery and definitive restorations were placed 4 to 6 months later. Patients were scheduled for followup at 6, 12, 18, and 24 months and annually up to 5 years. At each followup plaque level and bleeding scores were assessed and every complication was recorded. Results. The overall follow-up range was 12 to 73 months (mean 38.8 months. No implant failures were recorded to date, leading to a cumulative implant survival rate of 100%. Biological complications were recorded such as alveolar mucositis (11.8% patients, peri-implantitis (5.9% patients, and temporomandibular joint pain (5.9% patients. The most common prosthetic complications were the fracture or detachment of one or multiple acrylic teeth in both the temporary (20.6% patients and definitive (17.7% patients prosthesis and the minor acrylic fractures in the temporary (14.7% patients and definitive (2.9% patients prosthesis. Hygienic complications occurred in 38.2% patients. No patients’ dissatisfactions were recorded. Conclusions. The high cumulative implant survival rate indicates that this technique could be considered a viable treatment option. An effective recall program is important to early intercept and correct prosthetic and biologic complications in order to avoid implant and prosthetic failures.

  6. Comparison of arch forms between Turkish and North American

    Directory of Open Access Journals (Sweden)

    Ahmet A. Celebi

    2016-04-01

    Full Text Available ABSTRACT Objective: The aim of this study was to clarify the morphological differences in the mandibular arches of Turkish and North American white subjects. Methods: The sample included 132 Turkish (34 Class I, 58 Class II, and 40 Class III and 160 North American (60 Class I, 50 Class II, and 50 Class III subjects. The most facial portion of 13 proximal contact areas was digitized from photocopied images of patients' mandibular dental arches. Clinical bracket points were calculated for each tooth based on mandibular tooth thickness data. Four linear and two proportional measurements were taken. The subjects were grouped according to arch form types (tapered, ovoid and square in order to have frequency distribution compared between ethnic groups in each Angle classification. Results: The Turkish group showed significantly lower molar depth and more significant molar width-depth (W/D ratio in all three Angle classifications. On the other hand, the Turkish group also showed a significantly larger intercanine width in Class III malocclusion and intermolar width in Class II malocclusion. The most frequent arch forms seen were the ovoid arch form in the Turkish group and the tapered form in the white group. Conclusions: Our results demonstrate that when treating Turkish patients, one should expect to use preformed ovoid arch form orthodontic wires in a significant percentage of patients.

  7. Method of mechanical holding of cantilever chip for tip-scan high-speed atomic force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Shingo [Department of Physics, College of Science and Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Uchihashi, Takayuki; Ando, Toshio [Department of Physics, College of Science and Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Bio-AFM Frontier Research Center, College of Science and Engineering, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Core Research for Evolutional Science and Technology of the Japan Science and Technology Agency, 7 Goban-cho, Chiyoda-ku, Tokyo 102-0076 (Japan)

    2015-06-15

    In tip-scan atomic force microscopy (AFM) that scans a cantilever chip in the three dimensions, the chip body is held on the Z-scanner with a holder. However, this holding is not easy for high-speed (HS) AFM because the holder that should have a small mass has to be able to clamp the cantilever chip firmly without deteriorating the Z-scanner’s fast performance, and because repeated exchange of cantilever chips should not damage the Z-scanner. This is one of the reasons that tip-scan HS-AFM has not been established, despite its advantages over sample stage-scan HS-AFM. Here, we present a novel method of cantilever chip holding which meets all conditions required for tip-scan HS-AFM. The superior performance of this novel chip holding mechanism is demonstrated by imaging of the α{sub 3}β{sub 3} subcomplex of F{sub 1}-ATPase in dynamic action at ∼7 frames/s.

  8. Level-ARCH Short Rate Models with Regime Switching

    DEFF Research Database (Denmark)

    Christiansen, Charlotte

    This paper introduces regime switching volatility into level- ARCH models for the short rates of the US, the UK, and Germany. Once regime switching and level effects are included there are no gains from including ARCH effects. It is of secondary importance exactly how the regime switching is spec...

  9. Determining the thermal expansion coefficient of thin films for a CMOS MEMS process using test cantilevers

    International Nuclear Information System (INIS)

    Cheng, Chao-Lin; Fang, Weileun; Tsai, Ming-Han

    2015-01-01

    Many standard CMOS processes, provided by existing foundries, are available. These standard CMOS processes, with stacking of various metal and dielectric layers, have been extensively applied in integrated circuits as well as micro-electromechanical systems (MEMS). It is of importance to determine the material properties of the metal and dielectric films to predict the performance and reliability of micro devices. This study employs an existing approach to determine the coefficients of thermal expansion (CTEs) of metal and dielectric films for standard CMOS processes. Test cantilevers with different stacking of metal and dielectric layers for standard CMOS processes have been designed and implemented. The CTEs of standard CMOS films can be determined from measurements of the out-of-plane thermal deformations of the test cantilevers. To demonstrate the feasibility of the present approach, thin films prepared by the Taiwan Semiconductor Manufacture Company 0.35 μm 2P4M CMOS process are characterized. Eight test cantilevers with different stacking of CMOS layers and an auxiliary Si cantilever on a SOI wafer are fabricated. The equivalent elastic moduli and CTEs of the CMOS thin films including the metal and dielectric layers are determined, respectively, from the resonant frequency and static thermal deformation of the test cantilevers. Moreover, thermal deformations of cantilevers with stacked layers different to those of the test beams have been employed to verify the measured CTEs and elastic moduli. (paper)

  10. In vivo Study of the Accuracy of Dual-arch Impressions.

    Science.gov (United States)

    de Lima, Luciana Martinelli Santayana; Borges, Gilberto Antonio; Junior, Luiz Henrique Burnett; Spohr, Ana Maria

    2014-06-01

    This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a pattern. Ten impressions were made with each tray and impression material. The impressions were poured with Type IV gypsum. The width and height of the pattern and casts were measured in a profile projector (Nikon). The results were submitted to Student's t-test for one sample (α = 0.05). For the width distance, the plastic dual-arch trays with vinyl polysiloxane (4.513 mm) and with polyether (4.531 mm) were statistically wider than the pattern (4.489 mm). The metal dual-arch tray with vinyl polysiloxane (4.504 mm) and with polyether (4.500 mm) did not differ statistically from the pattern. For the height distance, only the metal dual-arch tray with polyether (2.253 mm) differed statistically from the pattern (2.310 mm). The metal dual-arch tray with vinyl polysiloxane, in the putty/wash viscosities, reproduced casts with less distortion in comparison with the same technique with the plastic dual-arch tray. The plastic or metal dual-arch trays with polyether reproduced cast with greater distortion. How to cite the article: Santayana de Lima LM, Borges GA, Burnett LH Jr, Spohr AM. In vivo study of the accuracy of dual-arch impressions. J Int Oral Health 2014;6(3):50-5.

  11. Aluminum nano-cantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nano-cantilevers using a very simple one mask contact UV lithography technique with lateral dimensions under 500 nm and vertical dimensions of approximately 100 nm. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Further...

  12. The effects of substrate layer thickness on piezoelectric vibration energy harvesting with a bimorph type cantilever

    Science.gov (United States)

    Palosaari, Jaakko; Leinonen, Mikko; Juuti, Jari; Jantunen, Heli

    2018-06-01

    In this research four piezoelectric bimorph type cantilevers for energy harvesting were manufactured, measured and analyzed to study the effects of substrate layer thickness on energy harvesting efficiency and durability under different accelerations. The cantilevers had the same dimensions of the piezoelectric ceramic components, but had different thicknesses of the steel substrate (no steel, 30 μm, 50 μm and 75 μm). The cantilevers were tuned to the same resonance frequency with different sizes of tip mass (2.13 g, 3.84 g, 4.17 g and 5.08 g). The energy harvester voltage outputs were then measured across an electrical load near to the resonance frequency (∼40 Hz) with sinusoidal vibrations under different accelerations. The stress exhibited by the four cantilevers was compared and analyzed and their durability was tested with accelerations up to 2.5 g-forces.

  13. A fixed partial appliance approach towards treatment of anterior single tooth crossbite: Report of two cases

    Directory of Open Access Journals (Sweden)

    M Gawthaman

    2017-01-01

    Full Text Available Crossbite can be treated using both removable and fixed appliances. This paper describes the report of two cases by a method of treating anterior single tooth in crossbite which is locked out of arch form with a simple fixed partial appliance. Orthodontic treatment was initiated by creating space for the locked out incisor using open coil spring and further corrected using MBT brackets and nitinol archwire for alignment. Treatment goals were achieved, and esthetics and occlusion were maintained postoperatively. Treatment objectives were obtained within a short duration using this technique, and there was an improvement in patients' smile.

  14. Design optimization of piezoresistive cantilevers for force sensing in air and water

    Science.gov (United States)

    Doll, Joseph C.; Park, Sung-Jin; Pruitt, Beth L.

    2009-01-01

    Piezoresistive cantilevers fabricated from doped silicon or metal films are commonly used for force, topography, and chemical sensing at the micro- and macroscales. Proper design is required to optimize the achievable resolution by maximizing sensitivity while simultaneously minimizing the integrated noise over the bandwidth of interest. Existing analytical design methods are insufficient for modeling complex dopant profiles, design constraints, and nonlinear phenomena such as damping in fluid. Here we present an optimization method based on an analytical piezoresistive cantilever model. We use an existing iterative optimizer to minimimize a performance goal, such as minimum detectable force. The design tool is available as open source software. Optimal cantilever design and performance are found to strongly depend on the measurement bandwidth and the constraints applied. We discuss results for silicon piezoresistors fabricated by epitaxy and diffusion, but the method can be applied to any dopant profile or material which can be modeled in a similar fashion or extended to other microelectromechanical systems. PMID:19865512

  15. Development of Robust and Standardized Cantilever Sensors Based on Biotin/Neutravidin Coupling for Antibody Detection

    Directory of Open Access Journals (Sweden)

    Christoph Gerber

    2013-04-01

    Full Text Available A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA, forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG and sheep anti-BSA(s-IgG antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 ´ 10−3 N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 ´ 10−3 N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay.

  16. Influence of cantilevered sheet pile deflection on adjacent roadways.

    Science.gov (United States)

    2009-06-01

    Cantilevered sheet pile walls are often used adjacent roadways as temporary support during construction. Excess movement of these walls has led to excessive roadway distress causing additional repairs to be necessary. This study assessed the effects ...

  17. Dynamic modelling and experimental study of cantilever beam with clearance

    International Nuclear Information System (INIS)

    Li, B; Jin, W; Han, L; He, Z

    2012-01-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  18. Dynamic modelling and experimental study of cantilever beam with clearance

    Science.gov (United States)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  19. Integrated Cantilever-Based Flow Sensors with Tunable Sensitivity for In-Line Monitoring of Flow Fluctuations in Microfluidic Systems

    Directory of Open Access Journals (Sweden)

    Nadine Noeth

    2013-12-01

    Full Text Available For devices such as bio-/chemical sensors in microfluidic systems, flow fluctuations result in noise in the sensor output. Here, we demonstrate in-line monitoring of flow fluctuations with a cantilever-like sensor integrated in a microfluidic channel. The cantilevers are fabricated in different materials (SU-8 and SiN and with different thicknesses. The integration of arrays of holes with different hole size and number of holes allows the modification of device sensitivity, theoretical detection limit and measurement range. For an average flow in the microliter range, the cantilever deflection is directly proportional to the flow rate fluctuations in the microfluidic channel. The SiN cantilevers show a detection limit below 1 nL/min and the thinnest SU-8 cantilevers a detection limit below 5 nL/min. Finally, the sensor is applied for in-line monitoring of flow fluctuations generated by external pumps connected to the microfluidic system.

  20. First Branchial Arch Fistula: A Rarity and a Surgical Challenge.

    Science.gov (United States)

    Rajkumar, J S; Ganesh, Deepa; Anirudh, J R; Akbar, S; Joshi, Niraj

    2016-06-01

    Although 2(nd) Branchial arch fistulae (from incomplete closure of Cervical sinus of His) are well known, 1(st) arch fistulae are much rarer (branchial arch fistula of the type II Arnot classification, which presented with two external openings of more than 20 years duration. Patient had a successful resection of all the concerned fistulous tract. Review of literature and the surgical challenges of the procedure are presented herewith.

  1. Variations in tooth size and arch dimensions in Malay schoolchildren.

    Science.gov (United States)

    Hussein, Khalid W; Rajion, Zainul A; Hassan, Rozita; Noor, Siti Noor Fazliah Mohd

    2009-11-01

    To compare the mesio-distal tooth sizes and dental arch dimensions in Malay boys and girls with Class I, Class II and Class III malocclusions. The dental casts of 150 subjects (78 boys, 72 girls), between 12 and 16 years of age, with Class I, Class II and Class III malocclusions were used. Each group consisted of 50 subjects. An electronic digital caliper was used to measure the mesio-distal tooth sizes of the upper and lower permanent teeth (first molar to first molar), the intercanine and intermolar widths. The arch lengths and arch perimeters were measured with AutoCAD software (Autodesk Inc., San Rafael, CA, U.S.A.). The mesio-distal dimensions of the upper lateral incisors and canines in the Class I malocclusion group were significantly smaller than the corresponding teeth in the Class III and Class II groups, respectively. The lower canines and first molars were significantly smaller in the Class I group than the corresponding teeth in the Class II group. The lower intercanine width was significantly smaller in the Class II group as compared with the Class I group, and the upper intermolar width was significantly larger in Class III group as compared with the Class II group. There were no significant differences in the arch perimeters or arch lengths. The boys had significantly wider teeth than the girls, except for the left lower second premolar. The boys also had larger upper and lower intermolar widths and lower intercanine width than the girls. Small, but statistically significant, differences in tooth sizes are not necessarily accompanied by significant arch width, arch length or arch perimeter differences. Generally, boys have wider teeth, larger lower intercanine width and upper and lower intermolar widths than girls.

  2. Lucy's flat feet: the relationship between the ankle and rearfoot arching in early hominins.

    Directory of Open Access Journals (Sweden)

    Jeremy M DeSilva

    Full Text Available BACKGROUND: In the Plio-Pleistocene, the hominin foot evolved from a grasping appendage to a stiff, propulsive lever. Central to this transition was the development of the longitudinal arch, a structure that helps store elastic energy and stiffen the foot during bipedal locomotion. Direct evidence for arch evolution, however, has been somewhat elusive given the failure of soft-tissue to fossilize. Paleoanthropologists have relied on footprints and bony correlates of arch development, though little consensus has emerged as to when the arch evolved. METHODOLOGY/PRINCIPAL FINDINGS: Here, we present evidence from radiographs of modern humans (n = 261 that the set of the distal tibia in the sagittal plane, henceforth referred to as the tibial arch angle, is related to rearfoot arching. Non-human primates have a posteriorly directed tibial arch angle, while most humans have an anteriorly directed tibial arch angle. Those humans with a posteriorly directed tibial arch angle (8% have significantly lower talocalcaneal and talar declination angles, both measures of an asymptomatic flatfoot. Application of these results to the hominin fossil record reveals that a well developed rearfoot arch had evolved in Australopithecus afarensis. However, as in humans today, Australopithecus populations exhibited individual variation in foot morphology and arch development, and "Lucy" (A.L. 288-1, a 3.18 Myr-old female Australopithecus, likely possessed asymptomatic flat feet. Additional distal tibiae from the Plio-Pleistocene show variation in tibial arch angles, including two early Homo tibiae that also have slightly posteriorly directed tibial arch angles. CONCLUSIONS/SIGNIFICANCE: This study finds that the rearfoot arch was present in the genus Australopithecus. However, the female Australopithecus afarensis "Lucy" has an ankle morphology consistent with non-pathological flat-footedness. This study suggests that, as in humans today, there was variation in arch

  3. Crozat appliance therapy for an arch-length discrepancy problem.

    Science.gov (United States)

    Parker, M

    1991-01-01

    The case involved a white male subject, aged 10 years 6 months, with a Class I molar relationship complicated by a deep overbite and impaction of all four permanent canines, which were completely blocked out of the arches. The growth rate of the arches was found to be abnormal, and there was premature loss of the deciduous teeth. Over a period of approximately 5 years, with intermittent pauses to allow growth to catch up with treatment, the Crozat removable appliance was used to help establish the arch form and correct the plane of occlusion.

  4. Analysis the effect of different geometries of AFM's cantilever on the dynamic behavior and the critical forces of three-dimensional manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Korayem, Moharam Habibnejad, E-mail: hkorayem@iust.ac.ir; Saraie, Maniya B.; Saraee, Mahdieh B.

    2017-04-15

    An important challenge when using an atomic force microscope (AFM) is to be able to control the force exerted by the AFM for performing various tasks. Nevertheless, the exerted force is proportional to the deflection of the AFM cantilever, which itself is affected by a cantilever's stiffness coefficient. Many papers have been published so far on the methods of obtaining the stiffness coefficients of AFM cantilevers in 2D; however, a comprehensive model is yet to be presented on 3D cantilever motion. The discrepancies between the equations of the 2D and 3D analysis are due to the number and direction of forces and moments that are applied to a cantilever. Moreover, in the 3D analysis, contrary to the 2D analysis, due to the interaction between the forces and moments applied on a cantilever, its stiffness values cannot be separately expressed for each direction; and instead, a stiffness matrix should be used to correctly derive the relevant equations. In this paper, 3D stiffness coefficient matrices have been obtained for three common cantilever geometries including the rectangular, V-shape and dagger-shape cantilevers. The obtained equations are validated by two methods. In the first approach, the Finite Element Method is combined with the cantilever deflection values computed by using the obtained stiffness matrices. In the second approach, by reducing the problem's parameters, the forces applied on a cantilever along different directions are compared with each other in 2D and 3D cases. Then the 3D manipulation of a stiff nanoparticle is modeled and simulated by using the stiffness matrices obtained for the three cantilever geometries. The obtained results indicate that during the manipulation process, the dagger-shaped and rectangular cantilevers exert the maximum and minimum amounts of forces on the stiff nanoparticle, respectively. Also, by examining the effects of different probe tip geometries, it is realized that a probe tip of cylindrical geometry

  5. Comparison of dental arch dimensions in models of preschool children with cleft lip/palate repaired by means of surgery alone versus controls.

    Science.gov (United States)

    Burhan, Ahmad S; Nawaya, Fehmieh R

    2016-09-01

    Cleft lip and palate (CLP) anomaly is one of the most prevalent congenital defects causing disturbances of dental arch dimensions. This study aimed at investigating differences in these dimensions between preschool children with cleft lip/palate and a matched control group representing healthy individuals with normal occlusion (NO). The sample of this cross-sectional analytical study consisted of 108 plaster models of children aged from 4 to 5.5 years. They were divided into five groups: the cleft lip group, the cleft palate (CP) group, the unilateral cleft lip and palate group, the bilateral cleft lip and palate group, and the NO group. The NO group was used as a control group. All cleft-affected children were treated only with surgery. Dental arch length and widths were measured. The dental arch dimensions of the cleft lip group were nearly similar to those in the controls. Moreover, the mandibular transverse widths of the CP group were close to those in the controls. However, the mandibular arch length and all maxillary dimensions of the CP group were smaller than those in the controls. In the unilateral cleft lip and palate group, the arch lengths in both jaws and the maxillary transverse widths were smaller than those in the controls, whereas the mandibular transverse widths were similar to those in the controls. In the bilateral cleft lip and palate group, the arch lengths in both jaws were close to those in the controls, but both arches were narrower than those in the controls. The various types of CLP were found to be associated with differences in most maxillary and some mandibular arch dimensions. These data can be used for cleft patient counseling and treatment planning.

  6. Difficulties in fitting the thermal response of atomic force microscope cantilevers for stiffness calibration

    International Nuclear Information System (INIS)

    Cole, D G

    2008-01-01

    This paper discusses the difficulties of calibrating atomic force microscope (AFM) cantilevers, in particular the effect calibrating under light fluid-loading (in air) and under heavy fluid-loading (in water) has on the ability to use thermal motion response to fit model parameters that are used to determine cantilever stiffness. For the light fluid-loading case, the resonant frequency and quality factor can easily be used to determine stiffness. The extension of this approach to the heavy fluid-loading case is troublesome due to the low quality factor (high damping) caused by fluid-loading. Simple calibration formulae are difficult to realize, and the best approach is often to curve-fit the thermal response, using the parameters of natural frequency and mass ratio so that the curve-fit's response is within some acceptable tolerance of the actual thermal response. The parameters can then be used to calculate the cantilever stiffness. However, the process of curve-fitting can lead to erroneous results unless suitable care is taken. A feedback model of the fluid–structure interaction between the unloaded cantilever and the hydrodynamic drag provides a framework for fitting a modeled thermal response to a measured response and for evaluating the parametric uncertainty of the fit. The cases of uncertainty in the natural frequency, the mass ratio, and combined uncertainty are presented and the implications for system identification and stiffness calibration using curve-fitting techniques are discussed. Finally, considerations and recommendations for the calibration of AFM cantilevers are given in light of the results of this paper

  7. Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children

    International Nuclear Information System (INIS)

    Zhong, Yumin; Zhu, Ming; Sun, Aimin; Li, Yuhua; Jaffe, Richard B.; Gao, Wei

    2007-01-01

    Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information. (orig.)

  8. Cantilever-based sensor with integrated optical read-out using single mode waveguides

    DEFF Research Database (Denmark)

    Nordström, Maria; Zauner, Dan; Calleja, Montserrat

    2007-01-01

    This work presents the design, fabrication and mechanical characterisation of an integrated optical read-out scheme for cantilever-based biosensors. A cantilever can be used as a biosensor by monitoring its bending caused by the surface stress generated due to chemical reactions occurring on its...... surface. Here, we present a novel integrated optical read-out scheme based on single-mode waveguides that enables the fabrication of a compact system. The complete system is fabricated in the polymer SU-8. This manuscript shows the principle of operation and the design well as the fabrication...

  9. Is the South African exchange rate volatile? Application of the arch framework.

    Directory of Open Access Journals (Sweden)

    Thato Julius Mokoma

    2015-04-01

    Full Text Available This study applies the autoregressive conditional heteroscedasticity (ARCH model to forecast exchange rate volatility in South Africa for the period 1990Q1 to 2014Q2. The ARCH (1 and ARCH (2 models were constructed using four variables; namely, exchange rate, gross domestic product, inflation and interest rates. Upon addressing the issue of stationarity, the models were fitted and the ARCH (1 model was found to be fit. This model revealed a high volatility of exchange rate compared to the ARCH (2 model. Prior to forecasting, the selected model was subjected to a battery of diagnostics tests and was found to be stable and well specified. The forecasts from the ARCH (1 model proved that in the near future, exchange rate will not be highly volatile though SA will experience depreciation in its currency.

  10. Does work-to-family conflict really matter for health? Cross-sectional, prospective cohort and fixed-effects analyses.

    Science.gov (United States)

    Oshio, Takashi; Inoue, Akiomi; Tsutsumi, Akizumi

    2017-02-01

    It is well known that work-to-family conflict (WFC) is negatively associated with employees' health outcomes, including mental health and health behavior. However, the associations may be overstated because of insufficient control for unobserved individual attributes. To address this possibility, we compared the associations between WFC and health observed from a cross-sectional, prospective cohort and from fixed-effects regression models. We analyzed data from a Japanese occupational cohort survey of 15,102 observations from 7551 individuals (5947 men and 1604 women), which were collected in two waves with a one-year interval. We constructed a binary variable of high WFC and considered psychological distress measured using the Kessler 6 (K6) score, job and life dissatisfaction, and five types of health behavior (current smoking, problem drinking, leisure-time physical inactivity, sickness absence, and refraining from medical care). Results showed that for men, a high WFC increased the probability of reporting psychological distress (K6 score ≥ 5); this increased by 12.4% in a fixed-effects model. The association was substantially limited, as compared to the increase of 30.9% and 23.2% observed in cross-sectional and prospective cohort models, respectively; however, the association remained significant. Similar patterns were observed for job and life dissatisfaction. In contrast, the associations of WFC with all five types of health behavior were non-significant after controlling for fixed effects. We obtained generally similar results for women and found no substantial gender difference in the fixed-effects models. We concluded that the associations of WFC with employees' mental health and subjective well-being were robust, whereas the association between WFC and health behavior was generally limited. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. DESIGN of MICRO CANTILEVER BEAM for VAPOUR DETECTION USING COMSOL MULTI PHYSICS SOFTWARE

    OpenAIRE

    Sivacoumar R; Parvathy JM; Pratishtha Deep

    2015-01-01

    This paper gives an overview of micro cantilever beam of various shapes and materials for vapour detection. The design of micro cantilever beam, analysis and simulation is done for each shape. The simulation is done using COMSOL Multi physics software using structural mechanics and chemical module. The simulation results of applied force and resulting Eigen frequencies will be analyzed for different beam structures. The vapour analysis is done using flow cell that consists of chemical pill...

  12. Common fixed points in best approximation for Banach operator pairs with Ciric type I-contractions

    Science.gov (United States)

    Hussain, N.

    2008-02-01

    The common fixed point theorems, similar to those of Ciric [Lj.B. Ciric, On a common fixed point theorem of a Gregus type, Publ. Inst. Math. (Beograd) (N.S.) 49 (1991) 174-178; Lj.B. Ciric, On Diviccaro, Fisher and Sessa open questions, Arch. Math. (Brno) 29 (1993) 145-152; Lj.B. Ciric, On a generalization of Gregus fixed point theorem, Czechoslovak Math. J. 50 (2000) 449-458], Fisher and Sessa [B. Fisher, S. Sessa, On a fixed point theorem of Gregus, Internat. J. Math. Math. Sci. 9 (1986) 23-28], Jungck [G. Jungck, On a fixed point theorem of Fisher and Sessa, Internat. J. Math. Math. Sci. 13 (1990) 497-500] and Mukherjee and Verma [R.N. Mukherjee, V. Verma, A note on fixed point theorem of Gregus, Math. Japon. 33 (1988) 745-749], are proved for a Banach operator pair. As applications, common fixed point and approximation results for Banach operator pair satisfying Ciric type contractive conditions are obtained without the assumption of linearity or affinity of either T or I. Our results unify and generalize various known results to a more general class of noncommuting mappings.

  13. An experimentally validated bimorph cantilever model for piezoelectric energy harvesting from base excitations

    International Nuclear Information System (INIS)

    Erturk, A; Inman, D J

    2009-01-01

    Piezoelectric transduction has received great attention for vibration-to-electric energy conversion over the last five years. A typical piezoelectric energy harvester is a unimorph or a bimorph cantilever located on a vibrating host structure, to generate electrical energy from base excitations. Several authors have investigated modeling of cantilevered piezoelectric energy harvesters under base excitation. The existing mathematical modeling approaches range from elementary single-degree-of-freedom models to approximate distributed parameter solutions in the sense of Rayleigh–Ritz discretization as well as analytical solution attempts with certain simplifications. Recently, the authors have presented the closed-form analytical solution for a unimorph cantilever under base excitation based on the Euler–Bernoulli beam assumptions. In this paper, the analytical solution is applied to bimorph cantilever configurations with series and parallel connections of piezoceramic layers. The base excitation is assumed to be translation in the transverse direction with a superimposed small rotation. The closed-form steady state response expressions are obtained for harmonic excitations at arbitrary frequencies, which are then reduced to simple but accurate single-mode expressions for modal excitations. The electromechanical frequency response functions (FRFs) that relate the voltage output and vibration response to translational and rotational base accelerations are identified from the multi-mode and single-mode solutions. Experimental validation of the single-mode coupled voltage output and vibration response expressions is presented for a bimorph cantilever with a tip mass. It is observed that the closed-form single-mode FRFs obtained from the analytical solution can successfully predict the coupled system dynamics for a wide range of electrical load resistance. The performance of the bimorph device is analyzed extensively for the short circuit and open circuit resonance

  14. Spring constant measurement using a MEMS force and displacement sensor utilizing paralleled piezoresistive cantilevers

    Science.gov (United States)

    Kohyama, Sumihiro; Takahashi, Hidetoshi; Yoshida, Satoru; Onoe, Hiroaki; Hirayama-Shoji, Kayoko; Tsukagoshi, Takuya; Takahata, Tomoyuki; Shimoyama, Isao

    2018-04-01

    This paper reports on a method to measure a spring constant on site using a micro electro mechanical systems (MEMS) force and displacement sensor. The proposed sensor consists of a force-sensing cantilever and a displacement-sensing cantilever. Each cantilever is composed of two beams with a piezoresistor on the sidewall for measuring the in-plane lateral directional force and displacement. The force resolution and displacement resolution of the fabricated sensor were less than 0.8 µN and 0.1 µm, respectively. We measured the spring constants of two types of hydrogel microparticles to demonstrate the effectiveness of the proposed sensor, with values of approximately 4.3 N m-1 and 15.1 N m-1 obtained. The results indicated that the proposed sensor is effective for on-site spring constant measurement.

  15. Direct and quantitative broadband absorptance spectroscopy with multilayer cantilever probes

    Science.gov (United States)

    Hsu, Wei-Chun; Tong, Jonathan Kien-Kwok; Liao, Bolin; Chen, Gang

    2015-04-21

    A system for measuring the absorption spectrum of a sample is provided that includes a broadband light source that produces broadband light defined within a range of an absorptance spectrum. An interferometer modulates the intensity of the broadband light source for a range of modulation frequencies. A bi-layer cantilever probe arm is thermally connected to a sample arm having at most two layers of materials. The broadband light modulated by the interferometer is directed towards the sample and absorbed by the sample and converted into heat, which causes a temperature rise and bending of the bi-layer cantilever probe arm. A detector mechanism measures and records the deflection of the probe arm so as to obtain the absorptance spectrum of the sample.

  16. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review.

    Science.gov (United States)

    Ahlholm, Pekka; Sipilä, Kirsi; Vallittu, Pekka; Jakonen, Minna; Kotiranta, Ulla

    2018-01-01

    To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search. Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions. Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions. © 2016 by the American College of Prosthodontists.

  17. Study on Vibration of Heavy-Precision Robot Cantilever Based on Time-varying Glowworm Swarm Optimization Algorithm

    Science.gov (United States)

    Luo, T. H.; Liang, S.; Miao, C. B.

    2017-12-01

    A method of terminal vibration analysis based on Time-varying Glowworm Swarm Optimization algorithm is proposed in order to solve the problem that terminal vibration of the large flexible robot cantilever under heavy load precision.The robot cantilever of the ballastless track is used as the research target and the natural parameters of the flexible cantilever such as the natural frequency, the load impact and the axial deformation is considered. Taking into account the change of the minimum distance between the glowworm individuals, the terminal vibration response and adaptability could meet. According to the Boltzmann selection mechanism, the dynamic parameters in the motion simulation process are determined, while the influence of the natural frequency and the load impact as well as the axial deformation on the terminal vibration is studied. The method is effective and stable, which is of great theoretical basis for the study of vibration control of flexible cantilever terminal.

  18. Determination of Fluid Density and Viscosity by Analyzing Flexural Wave Propagations on the Vibrating Micro-Cantilever

    Directory of Open Access Journals (Sweden)

    Deokman Kim

    2017-10-01

    Full Text Available The determination of fluid density and viscosity using most cantilever-based sensors is based on changes in resonant frequency and peak width. Here, we present a wave propagation analysis using piezoelectrically excited micro-cantilevers under distributed fluid loading. The standing wave shapes of microscale-thickness cantilevers partially immersed in liquids (water, 25% glycerol, and acetone, and nanoscale-thickness microfabricated cantilevers fully immersed in gases (air at three different pressures, carbon dioxide, and nitrogen were investigated to identify the effects of fluid-structure interactions to thus determine the fluid properties. This measurement method was validated by comparing with the known fluid properties, which agreed well with the measurements. The relative differences for the liquids were less than 4.8% for the densities and 3.1% for the viscosities, and those for the gases were less than 6.7% for the densities and 7.3% for the viscosities, showing better agreements in liquids than in gases.

  19. A scanning probe microscope for magnetoresistive cantilevers utilizing a nested scanner design for large-area scans

    Directory of Open Access Journals (Sweden)

    Tobias Meier

    2015-02-01

    Full Text Available We describe an atomic force microscope (AFM for the characterization of self-sensing tunneling magnetoresistive (TMR cantilevers. Furthermore, we achieve a large scan-range with a nested scanner design of two independent piezo scanners: a small high resolution scanner with a scan range of 5 × 5 × 5 μm3 is mounted on a large-area scanner with a scan range of 800 × 800 × 35 μm3. In order to characterize TMR sensors on AFM cantilevers as deflection sensors, the AFM is equipped with a laser beam deflection setup to measure the deflection of the cantilevers independently. The instrument is based on a commercial AFM controller and capable to perform large-area scanning directly without stitching of images. Images obtained on different samples such as calibration standard, optical grating, EPROM chip, self-assembled monolayers and atomic step-edges of gold demonstrate the high stability of the nested scanner design and the performance of self-sensing TMR cantilevers.

  20. Cantilever steel post damaged by wind

    Directory of Open Access Journals (Sweden)

    Wei Sha

    2014-10-01

    Full Text Available An analysis for the cause of fracture failure of a cantilever steel sign post damaged by wind has been carried out. An unusual cause of failure has been identified, which is the subject of this paper. Microscopy and microanalysis of the fracture surface showed that the failure was due to pre-existing cracks, from the fabrication of the post. This conclusion was reached after detecting and analysing a galvanised layer on the fracture surfaces.

  1. Energy harvesting from radio frequency propagation using piezoelectric cantilevers

    KAUST Repository

    Al Ahmad, Mahmoud; Alshareef, Husam N.

    2012-01-01

    This work reports an induced strain in a piezoelectric cantilever due to radio frequency signal propagation. The piezoelectric actuator is coupled to radio frequency (RF) line through a gap of 0.25 mm. When a voltage signal of 10 Vpp propagates

  2. Structural properties and out-of-plane stability of roller bent steel arches

    NARCIS (Netherlands)

    Spoorenberg, R.C.

    2011-01-01

    In contemporary architecture the use of steel arches has seen a significant increase. They are applied in buildings and large span bridges, combining structural design with architectural merits. For arches lacking lateral support (or freestanding arches) the out-of-plane structural stability

  3. Asymptotics of the QMLE for General ARCH(q) Models

    DEFF Research Database (Denmark)

    Kristensen, Dennis; Rahbek, Anders Christian

    2009-01-01

    -ARCH -- are derived. Strong consistency is established under the assumptions that the ARCH process is geometrically ergodic, the conditional variance function has a finite log-moment, and finite second moment of the rescaled error. Asymptotic normality of the estimator is established under the additional assumption...

  4. Frequency Invariability of (Pb,La)(Zr,Ti)O₃ Antiferroelectric Thick-Film Micro-Cantilevers.

    Science.gov (United States)

    An, Kun; Jin, Xuechen; Meng, Jiang; Li, Xiao; Ren, Yifeng

    2018-05-13

    Micro-electromechanical systems comprising antiferroelectric layers can offer both actuation and transduction to integrated technologies. Micro-cantilevers based on the (Pb 0.97 La 0.02 )(Zr 0.95 Ti 0.05 )O₃ (PLZT) antiferroelectric thick film are fabricated by the micro-nano manufacturing process, to utilize the effect of phase transition induced strain and sharp phase switch of antiferroelectric materials. When micro-cantilevers made of antiferroelectric thick films were driven by sweep voltages, there were two resonant peaks corresponding to the natural frequency shift from 27.8 to 27.0 kHz, before and after phase transition. This is the compensation principle for the PLZT micro-cantilever to tune the natural frequency by the amplitude modulation of driving voltage, rather than of frequency modulation. Considering the natural frequency shift about 0.8 kHz and the frequency tuning ability about 156 Hz/V before the phase transition, this can compensate the frequency shift caused by increasing temperature by tuning only the amplitude of driving voltage, when the ultrasonic micro-transducer made of antiferroelectric thick films works for such a long period. Therefore, antiferroelectric thick films with hetero-structures incorporated into PLZT micro-cantilevers not only require a lower driving voltage (no more than 40 V) than rival bulk piezoelectric ceramics, but also exhibit better performance of frequency invariability, based on the amplitude modulation.

  5. Comparative analysis of the construction solution variants for flat arch coverings of buildings

    Directory of Open Access Journals (Sweden)

    Ibragimov Aleksandr Mayorovich

    2014-03-01

    Full Text Available Arch structures of long span buildings’ coverings are more beneficial in respect to material expenses, than beam and frame systems. Constructive schemes of roof frameworks of arch coverings are diverse, which means their operation under loading differs much. The authors offer a number of construction solutions for flat arch coverings of long span buildings. The comparative analysis of these construction solutions is presented. The operation of radial link arch is observed. The arch consists of discontinuous top chord and radial bowstring under the single load (uniformly distributed and concentrated in nods with different spans and rises. The problem of radial link arch optimization is solved in dependence with arising forces and rise. The optimal camber of arch was found. In further works the authors plan to analyze spans more than 36 meters and solve the problem in case of asymmetrical loadings.

  6. Lateral testing of glued laminated timber tudor arch

    Science.gov (United States)

    Douglas R. Rammer; Philip Line

    2016-01-01

    Glued laminated timber Tudor arches have been in wide use in the United States since the 1930s, but detailed knowledge related to seismic design in modern U.S. building codes is lacking. FEMA P-695 (P-695) is a methodology to determine seismic performance factors for a seismic force resisting system. A limited P-695 study for glued laminated timber arch structures...

  7. Twin - Arch technique. Revival of the "edgewise -Technique"?

    Directory of Open Access Journals (Sweden)

    Jacob Karp

    2012-01-01

    The SNB – Bracket brings a new dimension into the orthodontic world which is most apparent in extraction cases. Its Teflon – like material has a very low friction coefficient thus, reducing the treatment time considerably. Through the use of low dimensioned arch wires, the Twin – Arch Technique becomes a Light – wire system and simultaneously provides good anchorage and torque control.

  8. Micro-fabricated flexible PZT cantilever using d33 mode for energy harvesting

    Science.gov (United States)

    Cho, Hyunok; Park, Jongcheol; Park, Jae Yeong

    2017-12-01

    This paper presents a micro-fabricated flexible and curled PZT [Pb(Zr0.52Ti0.48)O3] cantilever using d33 piezoelectric mode for vibration based energy harvesting applications. The proposed cantilever based energy harvester consists of polyimide, PZT thin film, and inter-digitated IrOx electrodes. The flexible cantilever was formed using bulk-micromachining on a silicon wafer to integrate it with ICs. The d33 piezoelectric mode was applied to achieve a large output voltage by using inter-digitated electrodes, and the PZT thin film on polyimide layer has a remnant polarization and coercive filed of approximately 2 P r = 47.9 μC/cm2 and 2 E c = 78.8 kV/cm, respectively. The relative dielectric constant was 900. The fabricated micro-electromechanical systems energy harvester generated output voltages of 1.2 V and output power of 117 nW at its optimal resistive load of 6.6 MΩ from its resonant frequency of 97.8 Hz with an acceleration of 5 m/s2.

  9. Discussion on construction project of lining arch reinforcing stone arch bridge%内衬拱加固石拱桥施工方案探讨

    Institute of Scientific and Technical Information of China (English)

    乔钧

    2012-01-01

    分析了石拱桥的常见病害及其原因,总结了石拱桥的加固技术,结合一个工程实例,对内衬拱加固石拱桥的有效施工方案进行了详细阐述,并证明了该加固方案的有效性。%This paper analysed the common diseases and its reasons of stone arch bridge, summed up the reinforcement technology of stone arch bridge, combining with an engineering example, elaborated in detail the effective construction scheme of lining arch reinforcing stone arch bridge, and proved the effectiveness of this reinforcement scheme.

  10. An Experimental and Theoretical Investigation of Electrostatically Coupled Cantilever Microbeams

    KAUST Repository

    Ilyas, Saad; Chappanda, Karumbaiah N.; Hafiz, Md Abdullah Al; Ramini, Abdallah; Younis, Mohammad I.

    2016-01-01

    We present an experimental and theoretical investigation of the static and dynamic behavior of electrostatically coupled laterally actuated silicon microbeams. The coupled beam resonators are composed of two almost identical flexible cantilever

  11. System identification and control parameter optimization for a stylus profiler with exchangeable cantilevers

    OpenAIRE

    Felix Ströer; Katharina Trinkaus; Indek Raid; Jörg Seewig

    2018-01-01

    Stylus instruments are widely used in production metrology due to their robustness. Interchangeable cantilevers allow a wide range of measuring tasks to be covered with one measuring device. When approaching the sample, the positioning of the stylus instrument tip relative to the measurement object has to be accomplished in a controlled way in order to prevent damages to the specimen and the stylus cantilever. This is achieved by a closed-loop control. We present a method for the objective de...

  12. Optimal graft diameter and location reduce postoperative complications after total arch replacement with long elephant trunk for arch aneurysm.

    Science.gov (United States)

    Kondoh, Haruhiko; Funatsu, Toshihiro; Toda, Koich; Kainuma, Satoshi; Kuki, Satoru; Taniguchi, Kazuhiro

    2011-08-01

    Total arch replacement with an elephant trunk is a standard treatment for arch aneurysm, but serious complications, such as paraplegia and peripheral embolization caused by flapping of the elephant trunk, remain. Moreover, dilation of the descending aorta and retrograde flow into the peri-graft space at the distal elephant trunk are frequent problems. We hypothesized that optimal graft diameter and location would reduce complications after total arch replacement with a long elephant trunk by achieving complete thrombosis and minimal dilation of the descending aorta around the elephant trunk. We treated 65 patients with arch aneurysm by total arch replacement with a long elephant trunk anastomosed at the base of the innominate artery. The graft diameter was undersized (10%-20% of the distal aorta's diameter). Elephant trunk length was determined by preoperative computed tomography to locate the distal end at Th6 to Th8. Thrombosis around the elephant trunk, diameter of the descending aorta, and distance between the descending aorta and the graft near the distal end of the elephant trunk were evaluated using computed tomography. The distal end of the elephant trunk was located at Th 8 ± 1. There were no operative deaths, 3 patients (5%) died in the hospital, and 3 patients (5%) experienced spinal cord injury, including 1 in whom permanent paraplegia developed. Computed tomography revealed complete thrombosis around the elephant trunk in 58 patients (89%). The descending aorta did not dilate further, and distance between the descending aorta and the graft progressively decreased. Optimal graft diameter and location minimized postoperative complications, with complete thrombosis and no dilation of the descending aorta around the long elephant trunk in most patients. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. NASA ARCH- A FILE ARCHIVAL SYSTEM FOR THE DEC VAX

    Science.gov (United States)

    Scott, P. J.

    1994-01-01

    The function of the NASA ARCH system is to provide a permanent storage area for files that are infrequently accessed. The NASA ARCH routines were designed to provide a simple mechanism by which users can easily store and retrieve files. The user treats NASA ARCH as the interface to a black box where files are stored. There are only five NASA ARCH user commands, even though NASA ARCH employs standard VMS directives and the VAX BACKUP utility. Special care is taken to provide the security needed to insure file integrity over a period of years. The archived files may exist in any of three storage areas: a temporary buffer, the main buffer, and a magnetic tape library. When the main buffer fills up, it is transferred to permanent magnetic tape storage and deleted from disk. Files may be restored from any of the three storage areas. A single file, multiple files, or entire directories can be stored and retrieved. archived entities hold the same name, extension, version number, and VMS file protection scheme as they had in the user's account prior to archival. NASA ARCH is capable of handling up to 7 directory levels. Wildcards are supported. User commands include TEMPCOPY, DISKCOPY, DELETE, RESTORE, and DIRECTORY. The DIRECTORY command searches a directory of savesets covering all three archival areas, listing matches according to area, date, filename, or other criteria supplied by the user. The system manager commands include 1) ARCHIVE- to transfer the main buffer to duplicate magnetic tapes, 2) REPORTto determine when the main buffer is full enough to archive, 3) INCREMENT- to back up the partially filled main buffer, and 4) FULLBACKUP- to back up the entire main buffer. On-line help files are provided for all NASA ARCH commands. NASA ARCH is written in DEC VAX DCL for interactive execution and has been implemented on a DEC VAX computer operating under VMS 4.X. This program was developed in 1985.

  14. A theoretical method for calculating the collapse load of steel circular arches

    NARCIS (Netherlands)

    Spoorenberg, R.C.; Snijder, H.H.; Hoenderkamp, J.C.D.

    2012-01-01

    Arches are frequently used in large span structures like bridges and roofs. Although these structural elements may be prone to various instability phenomena, stocky arches or slender arches with sufficient lateral bracing fail due to plastic collapse instead of in-plane buckling or out-of-plane

  15. Resonant-cantilever bio/chemical sensors with an integrated heater for both resonance exciting optimization and sensing repeatability enhancement

    International Nuclear Information System (INIS)

    Yu Haitao; Li Xinxin; Gan Xiaohua; Liu Yongjing; Liu Xiang; Xu Pengcheng; Li Jungang; Liu Min

    2009-01-01

    With an integrated resonance exciting heater and a self-sensing piezoresistor, resonant micro-cantilever bio/chemical sensors are optimally designed and fabricated by micromachining techniques. This study is emphasized on the optimization of the integrated heating resistor. Previous research has put the heater at either the cantilever clamp end, the midpoint or the free end. Aiming at sufficiently high and stable resonant amplitude, our research indicates that the optimized location of the thermal-electric exciting resistor is the clamp end instead of other positions. By both theoretical analysis and resonance experiments where three heating resistors are placed at the three locations of the fabricated cantilever, it is clarified that the clamp end heating provides the most efficient resonance excitation in terms of resonant amplitude, Q-factor and resonance stability. Besides, the optimized combination of dc bias and ac voltage is determined by both analysis and experimental verification. With the optimized heating excitation, the resonant cantilever is used for biotin–avidin-specific detection, resulting in a ±0.1 Hz ultra-low noise floor of the frequency signal and a 130 fg mass resolution. In addition to resonance excitation, the heater is used to heat up the cantilever for speed-up desorption after detection that helps rapid and repeated sensing to chemical vapor. The clamp end is determined (by simulation) as the optimal heating location for uniform temperature distribution on the cantilever. Using the resonant cantilever, a rapid and repeated sensing experiment on dimethyl methylphosphonate (DMMP) vapor shows that a short-period heating at the detection interval significantly quickens the signal recovery and enhances the sensing repeatability

  16. Polymeric Flexible Immunosensor Based on Piezoresistive Micro-Cantilever with PEDOT/PSS Conductive Layer

    Directory of Open Access Journals (Sweden)

    Rui Zhao

    2018-02-01

    Full Text Available In this paper, a fully polymeric micro-cantilever with the surface passivation layer of parylene-C and the strain resistor of poly(3,4-ethylenedioxythiophene/poly (styrene sulfonate (PEDOT/PSS was proposed and demonstrated for immunoassays. By optimizing the design and fabrication of the polymeric micro-cantilever, a square resistance of 220 Ω/□ for PEDOT/PSS conductive layer have been obtained. The experimental spring constant and the deflection sensitivity were measured to be 0.017 N/m and 8.59 × 10−7 nm−1, respectively. The biological sensing performances of polymeric micro-cantilever were investigated by the immunoassay for human immunoglobulin G (IgG. The immunosensor was experimentally demonstrated to have a linear behavior for the detection of IgG within the concentrations of 10~100 ng/mL with a limit of detection (LOD of 10 ng/mL. The experimental results indicate that the proposed polymeric flexible conductive layer-based sensors are capable of detecting trace biological substances.

  17. Polymeric Flexible Immunosensor Based on Piezoresistive Micro-Cantilever with PEDOT/PSS Conductive Layer.

    Science.gov (United States)

    Zhao, Rui; Sun, Ying

    2018-02-03

    In this paper, a fully polymeric micro-cantilever with the surface passivation layer of parylene-C and the strain resistor of poly(3,4-ethylenedioxythiophene)/poly (styrene sulfonate) (PEDOT/PSS) was proposed and demonstrated for immunoassays. By optimizing the design and fabrication of the polymeric micro-cantilever, a square resistance of 220 Ω/□ for PEDOT/PSS conductive layer have been obtained. The experimental spring constant and the deflection sensitivity were measured to be 0.017 N/m and 8.59 × 10 -7 nm -1 , respectively. The biological sensing performances of polymeric micro-cantilever were investigated by the immunoassay for human immunoglobulin G (IgG). The immunosensor was experimentally demonstrated to have a linear behavior for the detection of IgG within the concentrations of 10~100 ng/mL with a limit of detection (LOD) of 10 ng/mL. The experimental results indicate that the proposed polymeric flexible conductive layer-based sensors are capable of detecting trace biological substances.

  18. SU-8 cantilevers for bio/chemical sensing; Fabrication, characterisation and development of novel read-out methods

    DEFF Research Database (Denmark)

    Nordström, M.; Keller, Stephan Urs; Lillemose, Michael

    2008-01-01

    Here, we present the activities within our research group over the last five years with cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interesting polymer for fabrication of cantilevers for bio/chemical sensing due to its simple processing and low Young's modulus. We show...

  19. Characterization of piesoelectric ZnO thin films and the fabrication of piezoelectric micro-cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Raegan Lynn [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    In Atomic Force Microscopy (AFM), a microcantilever is raster scanned across the surface of a sample in order to obtain a topographical image of the sample's surface. In a traditional, optical AFM, the sample rests on a bulk piezoelectric tube and a control loop is used to control the tip-sample separation by actuating the piezo-tube. This method has several disadvantages--the most noticeable one being that response time of the piezo-tube is rather long which leads to slow imaging speeds. One possible solution aimed at improving the speed of imaging is to incorporate a thin piezoelectric film on top of the cantilever beam. This design not only improves the speed of imaging because the piezoelectric film replaces the piezo-tube as an actuator, but the film can also act as a sensor. In addition, the piezoelectric film can excite the cantilever beam near its resonance frequency. This project aims to fabricate piezoelectric microcantilevers for use in the AFM. Prior to fabricating the cantilevers and also part of this project, a systematic study was performed to examine the effects of deposition conditions on the quality of piezoelectric ZnO thin films deposited by RF sputtering. These results will be presented. The deposition parameters that produced the highest quality ZnO film were used in the fabrication of the piezoelectric cantilevers. Unfortunately, the fabricated cantilevers warped due to the intrinsic stress of the ZnO film and were therefore not usable in the AFM. The complete fabrication process will be detailed, the results will be discussed and reasons for the warping will be examined.

  20. Intrinsically aligned chemo-mechanical functionalization of twin cantilever structures

    International Nuclear Information System (INIS)

    Toffoli, V; Esch, F; Melli, M; Pozzato, A; Tormen, M; Lazzarino, M; Cataruzza, F; Carrato, S; Scoles, G

    2008-01-01

    Mechanical oscillators became a main focus of research in recent years for potential applications in biomolecule detectors. We recently demonstrated the feasibility of a scheme based on twin cantilevers with a sensitivity down to the single molecule. This approach is extremely promising under the condition that the two terminals of the device can be functionalized with high selectivity and nanometric accuracy by linker molecules. Here we demonstrate a chemo-mechanical method to achieve the intrinsically aligned functionalization of two silicon surfaces, which can be separated by a gap controllable with nanometric precision. The chemical binding of the target molecules in the selected position is obtained through a cycloaddition reaction which exploits the reactivity of the freshly cleaved surfaces that form when the cantilever gap is created. The general validity of this approach is shown by the use in different chemical environments of two compounds with different reactive functional groups.

  1. Electromechanical model of a resonating nano-cantilever-based sensor for high-resolution and high-sensitivity mass detection

    DEFF Research Database (Denmark)

    Abadal, G.; Davis, Zachary James; Helbo, Bjarne

    2001-01-01

    A simple linear electromechanical model for an electrostatically driven resonating cantilever is derived. The model has been developed in order to determine dynamic quantities such as the capacitive current flowing through the cantilever-driver system at the resonance frequency, and it allows us ...

  2. CREATIVITY METHODS IN TEACHING THE ARCH-DESIGN STUDIO

    Directory of Open Access Journals (Sweden)

    EIGBEONAN Andrew B.

    2013-07-01

    Full Text Available The aim of this paper is to search and find methods of fostering creativity or ideas relating to creativity in teaching the arch-design studio. Teaching creativity through its methods will be making the students grounded in designing with creativity ideas and therefore we can have professionals that design and build with satisfaction, safety and complementary. It means we can have real buildings and places that satisfy our clients, the society and in harmony with the environment. Although there are similarities in the curricula of training architects all over the world, but educators go about it in their own convenient and suitable ways and styles. The ideas of creativity have been part of architecture from the onset, but are not deligently applied and also not formally incorporated in the curricula of training. The topic is also very relevant and timely as arch-educators and other stakeholders are of the opinion that something has to be done to improve the ways and methods of training architects, especially the teaching of the arch-design studio with regards to creativity. Through exploration of literature and interviews (physical and telephone call this paper finds methods of stimulating creativity ideas in the teaching of arch-design studio. Some of the methods of motivating creativity found in teaching the arch-design studio are: analogy, metaphors, biomimicry, brainstorming, attribute listing, mental map, TRIZ, restrictions, charrette, browsing, excursions, focus groups, other peoples viewpoints, using crazy ideas, using experts, visualizing a goal, working with dreams and images and giving students design tools such as drawings CAD and model making.

  3. Computer-Guided Implant Surgery in Fresh Extraction Sockets and Immediate Loading of a Full Arch Restoration: A 2-Year Follow-Up Study of 14 Consecutively Treated Patients

    Science.gov (United States)

    Daas, M.; Assaf, A.; Dada, K.; Makzoumé, J.

    2015-01-01

    Statement of Problem. Low scientific evidence is identified in the literature for combining implant placement in fresh extraction sockets with immediate function. Moreover, the few studies available on immediate implants in postextraction sites supporting immediate full-arch rehabilitation clearly lack comprehensive protocols. Purpose. The purpose of this study is to report outcomes of a comprehensive protocol using CAD-CAM technology for surgical planning and fabrication of a surgical template and to demonstrate that immediate function can be easily performed with immediate implants in postextraction sites supporting full-arch rehabilitation. Material and Methods. 14 subjects were consecutively rehabilitated (13 maxillae and 1 mandible) with 99 implants supporting full-arch fixed prostheses followed between 6 and 24 months (mean of 16 months). Outcome measures were prosthesis and implant success, biologic and prosthetic complications, pain, oedema evaluation, and radiographic marginal bone levels at surgery and then at 6, 12, 18, and 24 months. Data were analyzed with descriptive statistics. Results. The overall cumulative implant survival rate at mean follow-up time of 16 months was 97.97%. The average marginal bone loss was 0,9 mm. Conclusions. Within the limitations of this study, the results validate this treatment modality for full-arch rehabilitations with predictable outcomes and high survival rate after 2 years. PMID:26064119

  4. Motion planning and synchronized control of the dental arch generator of the tooth-arrangement robot.

    Science.gov (United States)

    Jiang, Jin-Gang; Zhang, Yong-De

    2013-03-01

    The traditional, manual method of reproducing the dental arch form is prone to numerous random errors caused by human factors. The purpose of this study was to investigate the automatic acquisition of the dental arch and implement the motion planning and synchronized control of the dental arch generator of the multi-manipulator tooth-arrangement robot for use in full denture manufacture. First, the mathematical model of the dental arch generator was derived. Then the kinematics and control point position of the dental arch generator of the tooth arrangement robot were calculated and motion planning of each control point was analysed. A hardware control scheme is presented, based on the industrial personal computer and control card PC6401. In order to gain single-axis, precise control of the dental arch generator, we studied the control pulse realization of high-resolution timing. Real-time, closed-loop, synchronous control was applied to the dental arch generator. Experimental control of the dental arch generator and preliminary tooth arrangement were gained by using the multi-manipulator tooth-arrangement robotic system. The dental arch generator can automatically generate a dental arch to fit a patient according to the patient's arch parameters. Repeated positioning accuracy is 0.12 mm for the slipways that drive the dental arch generator. The maximum value of single-point error is 1.83 mm, while the arc-width direction (x axis) is -33.29 mm. A novel system that generates the dental arch has been developed. The traditional method of manually determining the dental arch may soon be replaced by a robot to assist in generating a more individual dental arch. The system can be used to fabricate full dentures and bend orthodontic wires. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Dynamic stability analysis of circular arch subjected to follower forces with small disturbances; Judo kaju wo ukeru enkei arch no yuran ni yoru doteki kyodo to anteisei kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Fukuchi, N.; Okada, K. [Kyushu University, Fukuoka (Japan). Faculty of Engineering; Hirano, Y. [Sumitomo Heavy Industries, Ltd., Tokyo (Japan)

    1997-09-04

    This paper describes the deformation and dynamic stability of circular arch subjected to follower forces in a submerged membrane type marine structure reinforced by arch frames. Governing equations for finite deformations of the circular arch subjected to follower forces are introduced using an embedded curve coordinate, which are formulated by applying Galerkin method. In addition, equations of motion due to small disturbances under given condition of loading are introduced. Based on these equations, dynamic stability of the arch is analyzed by means of Runnge-Kutta-Gill method, to clarify the relationship between disturbances and instability regions and the resulting phenomena. Near the boundary regions of stability, both amplitude and cycle of deformation are greatly affected by the amplitude of disturbances. The dynamic instability is governed by the inverse symmetry primary mode with minimum characteristic frequency which is specific for the circular arch. The dynamic stability has high parameter dependency, and the instability regions have a complicated shapes. Although flattened arch has a smaller static critical load, it provides the dynamic stability against the disturbance. 5 refs., 10 figs.

  6. Strengthening Masonry Arches with Lime-Based Mortar Composite

    Directory of Open Access Journals (Sweden)

    Valerio Alecci

    2017-06-01

    Full Text Available In recent decades, many strengthening interventions on masonry elements were performed by using fiber reinforced polymers (FRPs. These advanced materials proved to be effective to increase the load-carrying capacity of masonry elements and to improve their structural behavior, avoiding the most critical failure modes. Despite the advantages of this technique compared to more traditional methods, FRP systems have disadvantages related to their low resistance to high temperatures, impossibility of application on wet surfaces, low permeability, and poor compatibility with masonry supports. Therefore, composite materials made of a fiber textile embedded in an inorganic matrix were recently proposed as alternatives to FRPs for strengthening historic masonry constructions. These composite materials are easier to install, have higher resistance to high temperatures, and permit higher vapor permeability than FRPs. The inorganic matrix is frequently a cement-based mortar, and the composite materials made of a fiber textile embedded in a cement-based mortar are usually identified as FRCM (fabric reinforced cementitious matrix composites. More recently, the use of natural lime mortar as an inorganic matrix has been proposed as an alternative to cement-based mortars when historic compatibility with the substrate is strictly required, as in case of restoration of historic buildings. In this paper, the effectiveness of a fabric made of basalt fibers embedded in lime mortar matrix (Basalt-FRLM for the strengthening of masonry arches is investigated. An experimental investigation was performed on 1:2 scaled brick masonry arches strengthened at the extrados with a layer of Basalt-FRLM and tested under vertical load. The results obtained are compared with previous results obtained by the authors by testing masonry arches strengthened at their extrados with FRCM and FRP composites. This investigation highlights the effectiveness of Basalt-FRLM in increasing load

  7. The static and dynamic behavior of MEMS arch resonators near veering and the impact of initial shapes

    KAUST Repository

    Hajjaj, Amal Z.

    2017-07-19

    We investigate experimentally and analytically the effect of initial shapes, arc and cosine wave, on the static and dynamic behavior of microelectromechanical systems (MEMS) arch resonators. We show that by carefully choosing the geometrical parameters and the initial shape of the arch, the veering phenomenon (avoided-crossing) among the first two symmetric modes can be strongly activated. To demonstrate this, we study electrothermally tuned and electrostatically driven initially curved MEMS resonators. Upon changing the electrothermal voltage, we demonstrate high frequency tunability of arc resonators compared to the cosine-configuration resonators for the first and third resonance frequencies. For arc beams, we show that the first resonance frequency increases up to twice its fundamental value and the third resonance frequency decreases until getting very close to the first resonance frequency triggering the veering phenomenon. Around the veering regime, we study experimentally and analytically the dynamic behavior of the arc beam for different electrostatic loads. The analytical study is based on a reduced order model of a nonlinear Euler–Bernoulli shallow arch beam model. The veering phenomenon is also confirmed through a finite-element multi-physics and nonlinear model.

  8. Fabrication of a cantilever-based microfluidic flow meter with nL min(-1) resolution

    DEFF Research Database (Denmark)

    Noeth, Nadine-Nicole; Keller, Stephan Sylvest; Boisen, Anja

    2011-01-01

    A microfluidic flow meter based on cantilever deflection is developed, showing a resolution down to 3 nL min(-1) for flows in the microliter range. The cantilevers are fabricated in SU-8 and have integrated holes with dimensions from 5 x 5 to20x 20 mu m(2). The holes make it possible to measure i......, hole-to-hole distance, amount of holes, etc) the sensitivity of the sensor can be changed....

  9. A mandibular implant-supported fixed complete dental prosthesis in a patient with Sjogren syndrome: case report.

    Science.gov (United States)

    Spinato, Sergio; Soardi, Carlo Maria; Zane, Anna Maria

    2010-06-01

    The article describes the treatment and 1 year follow-up of a patient with Sjogren syndrome, treated with 6 intraforaminal mandibular implants with delayed loading and an implant-retained fixed prosthesis. The maxillary arch has been treated with a complete denture. This made an enormous difference in comfort and function for the patient. Radiographic check-ups did not reveal any peri-implant bone loss after 1 year of loading.

  10. Higher Order Modes Excitation of Micro Cantilever Beams

    KAUST Repository

    Jaber, Nizar

    2014-05-01

    In this study, we present analytical and experimental investigation of electrically actuated micro cantilever based resonators. These devices are fabricated using polyimide and coated with chrome and gold layers from both sides. The cantilevers are highly curled up due to stress gradient, which is a common imperfection in surface micro machining. Using a laser Doppler vibrometer, we applied a noise signal to experimentally find the first four resonance frequencies. Then, using a data acquisition card, we swept the excitation frequency around the first four natural modes of vibrations. Theoretically, we derived a reduced order model using the Galerkin method to simulate the dynamics of the system. Extensive numerical analysis and computations were performed. The numerical analysis was able to provide good matching with experimental values of the resonance frequencies. Also, we proved the ability to excite higher order modes using partial electrodes with shapes that resemble the shape of the mode of interest. Such micro-resonators are shown to be promising for applications in mass and gas sensing.

  11. Maxillary Arch Dimension Changes of 3-5 Years Old Filipino Children

    Directory of Open Access Journals (Sweden)

    Abdol Hamid Zafarmand

    2014-11-01

    Full Text Available Background: The purpose of this study was to assess the dental arch dimensions in primary dentition of 3-5 years old Filipino children and determining the existence of sexual dimorphism.Materials and Methods: In this descriptive study, 60 Filipino preschool children aged 3-5 years old were selected from Manila city. Study casts were used for measurements of 3 arch dimensions: bicanine width, bimolar width, and arch length. The analyses were performed to compare values within age-groups and within gender-groups, besides reporting mean and standard deviations. The data were subjected to One-way ANOVA and Student t-test.Results: Significant differences were observed regarding dental arch dimensions among different ages and genders (p<0.05. Comparison between genders showed a statistically significant difference in bicanine width at the age of 4 (p=0.04, in bimolar width at age of 5 (p=0.006, and in arch length at age of 4 (p=0.03 and 5 (p=0.02. Differences within male group for different ages showed only arch length dimension was statistically significant (p=0.021. In females, however the comparison between age-groups also revealed a statistically significant difference in bicanine (p= 0.016 and bimolar widths (p=0.027 dimensions.Conclusion: The present study showed that dental arch dimensions, vary among different ages and genders of children. It also showed that a sexual dimorphism does exist between the gender groups.

  12. Reliability and Correlation of Static and Dynamic Foot Arch Measurement in a Healthy Pediatric Population.

    Science.gov (United States)

    Scholz, Timo; Zech, Astrid; Wegscheider, Karl; Lezius, Susanne; Braumann, Klaus-Michael; Sehner, Susanne; Hollander, Karsten

    2017-09-01

    Measurement of the medial longitudinal foot arch in children is a controversial topic, as there are many different methods without a definite standard procedure. The purpose of this study was to 1) investigate intraday and interrater reliability regarding dynamic arch index and static arch height, 2) explore the correlation between both arch indices, and 3) examine the variation of the medial longitudinal arch at two different times of the day. Eighty-six children (mean ± SD age, 8.9 ± 1.9 years) participated in the study. Dynamic footprint data were captured with a pedobarographic platform. For static arch measurements, a specially constructed caliper was used to assess heel-to-toe length and dorsum height. A mixed model was established to determine reliability and variation. Reliability was found to be excellent for the static arch height index in sitting (intraday, 0.90; interrater, 0.80) and standing positions (0.88 and 0.85) and for the dynamic arch index (both 1.00). There was poor correlation between static and dynamic assessment of the medial longitudinal arch (standing dynamic arch index, r = -0.138; sitting dynamic arch index, r = -0.070). Static measurements were found to be significantly influenced by the time of day (P body mass index (P mind. For clinical purposes, static and dynamic arch data should be interpreted separately.

  13. Precise mass determination of single cell with cantilever-based microbiosensor system.

    Directory of Open Access Journals (Sweden)

    Bogdan Łabędź

    Full Text Available Having determined the mass of a single cell of brewer yeast Saccharomyces cerevisiae by means of a microcantilever-based biosensor Cantisens CSR-801 (Concentris, Basel, Switzerland, it was found that its dry mass is 47,65 ± 1,05 pg. Found to be crucial in this mass determination was the cell position along the length of the cantilever. Moreover, calculations including cells positions on the cantilever provide a threefold better degree of accuracy than those which assume uniform mass distribution. We have also examined the influence of storage time on the single cell mass. Our results show that after 6 months there is an increase in the average mass of a single yeast cell.

  14. Precise mass determination of single cell with cantilever-based microbiosensor system.

    Science.gov (United States)

    Łabędź, Bogdan; Wańczyk, Aleksandra; Rajfur, Zenon

    2017-01-01

    Having determined the mass of a single cell of brewer yeast Saccharomyces cerevisiae by means of a microcantilever-based biosensor Cantisens CSR-801 (Concentris, Basel, Switzerland), it was found that its dry mass is 47,65 ± 1,05 pg. Found to be crucial in this mass determination was the cell position along the length of the cantilever. Moreover, calculations including cells positions on the cantilever provide a threefold better degree of accuracy than those which assume uniform mass distribution. We have also examined the influence of storage time on the single cell mass. Our results show that after 6 months there is an increase in the average mass of a single yeast cell.

  15. An Astigmatic Detection System for Polymeric Cantilever-based Sensors

    DEFF Research Database (Denmark)

    Hwu, En-Te; Liao, Hsien-Shun; Bosco, Filippo

    2012-01-01

    fluctuation measurements on cantilever beams with a subnanometer resolution. Furthermore, an external excitation can intensify the resonance amplitude, enhancing the signal- to-noise ratio. The full width at half maximum (FWHM) of the laser spot is 568 nm, which facilitates read-out on potentially...

  16. Automated measurement of uptake in cerebellum, liver, and aortic arch in full-body FDG PET/CT scans.

    Science.gov (United States)

    Bauer, Christian; Sun, Shanhui; Sun, Wenqing; Otis, Justin; Wallace, Audrey; Smith, Brian J; Sunderland, John J; Graham, Michael M; Sonka, Milan; Buatti, John M; Beichel, Reinhard R

    2012-06-01

    The purpose of this work was to develop and validate fully automated methods for uptake measurement of cerebellum, liver, and aortic arch in full-body PET/CT scans. Such measurements are of interest in the context of uptake normalization for quantitative assessment of metabolic activity and/or automated image quality control. Cerebellum, liver, and aortic arch regions were segmented with different automated approaches. Cerebella were segmented in PET volumes by means of a robust active shape model (ASM) based method. For liver segmentation, a largest possible hyperellipsoid was fitted to the liver in PET scans. The aortic arch was first segmented in CT images of a PET/CT scan by a tubular structure analysis approach, and the segmented result was then mapped to the corresponding PET scan. For each of the segmented structures, the average standardized uptake value (SUV) was calculated. To generate an independent reference standard for method validation, expert image analysts were asked to segment several cross sections of each of the three structures in 134 F-18 fluorodeoxyglucose (FDG) PET/CT scans. For each case, the true average SUV was estimated by utilizing statistical models and served as the independent reference standard. For automated aorta and liver SUV measurements, no statistically significant scale or shift differences were observed between automated results and the independent standard. In the case of the cerebellum, the scale and shift were not significantly different, if measured in the same cross sections that were utilized for generating the reference. In contrast, automated results were scaled 5% lower on average although not shifted, if FDG uptake was calculated from the whole segmented cerebellum volume. The estimated reduction in total SUV measurement error ranged between 54.7% and 99.2%, and the reduction was found to be statistically significant for cerebellum and aortic arch. With the proposed methods, the authors have demonstrated that

  17. Complex branchial fistula: a variant arch anomaly.

    Science.gov (United States)

    De Caluwé, D; Hayes, R; McDermott, M; Corbally, M T

    2001-07-01

    A 5-year-old boy presented with an infected left-sided branchial fistula. Despite antibiotic treatment and repeated excision of the fistula, purulent discharge from the wound persisted. Three-dimensional computed tomography (3D CT) reconstruction greatly facilitated the diagnosis and management of this case by showing the course of the fistulous tract. The complexity of the tract suggests that this represents a variant arch anomaly because it contains features of first, second, third, and fourth arch remnants. Copyright 2001 by W.B. Saunders Company.

  18. DNA damage in oral mucosa cells of patients with fixed orthodontic appliances.

    Directory of Open Access Journals (Sweden)

    Farzin Heravi

    2013-12-01

    Full Text Available The release of toxic metal ions from orthodontic alloys has induced concerns regarding the biocompatibility of fixed appliances. This study investigated the genotoxic effect of metal appliances in a sample of patients undergoing fixed orthodontic treatment.The study included twenty-five healthy individuals requiring orthodontic therapy in both jaws. The patients were treated by stainless steel orthodontic brackets and nickel-titanium or stainless steel arch wires. The oral mucosa cells were gathered just before the appliance placement and 9 months later. The cells were centrifuged, fixed and dropped onto slides. After staining, the micronucleus (MN assay was used to determine genome alteration. The data were analyzed by paired sample t-test.The mean micronuclei frequency in the buccal mucosa was 10.6 ± 5.7 per 1000 cells before the appliance placement and 9.2 ± 6.37 per 1000 cells 9 months later. No significant difference was found in the MN count before and 9 months after therapy (p=0.336.Under the conditions used in this study, application of fixed orthodontic appliances did not expose healthy individuals to increased risk of DNA damage in oral mucosa cells.

  19. Analysis of asymmetric resonance response of thermally excited silicon micro-cantilevers for mass-sensitive nanoparticle detection

    Science.gov (United States)

    Bertke, Maik; Hamdana, Gerry; Wu, Wenze; Suryo Wasisto, Hutomo; Uhde, Erik; Peiner, Erwin

    2017-06-01

    In this paper, the asymmetric resonance frequency (f 0) responses of thermally in-plane excited silicon cantilevers for a pocket-sized, cantilever-based airborne nanoparticle detector (Cantor) are analysed. By measuring the shift of f 0 caused by the deposition of nanoparticles (NPs), the cantilevers are used as a microbalance. The cantilever sensors are low cost manufactured from silicon by bulk-micromachining techniques and contain an integrated p-type heating actuator and a sensing piezoresistive Wheatstone bridge. f 0 is tracked by a homemade phase-locked loop (PPL) for real-time measurements. To optimize the sensor performance, a new cantilever geometry was designed, fabricated and characterized by its frequency responses. The most significant characterisation parameters of our application are f 0 and the quality factor (Q), which have high influences on sensitivity and efficiency of the NP detector. Regarding the asymmetric resonance signal, a novel fitting function based on the Fano resonance replacing the conventionally used function of the simple harmonic oscillator and a method to calculate Q by its fitting parameters were developed for a quantitative evaluation. To obtain a better understanding of the resonance behaviours, we analysed the origin of the asymmetric line shapes. Therefore, we compared the frequency response of the on-chip thermal excitation with an external excitation using an in-plane piezo actuator. In correspondence to the Fano effect, we could reconstruct the measured resonance curves by coupling two signals with constant amplitude and the expected signal of the cantilever, respectively. Moreover, the phase of the measurement signal can be analysed by this method, which is important to understand the locking process of the PLL circuit. Besides the frequency analysis, experimental results and calibration measurements with different particle types are presented. Using the described analysis method, decent results to optimize a next

  20. Tracheal Compression Caused by a Mediastinal Hematoma After Interrupted Aortic Arch Surgery.

    Science.gov (United States)

    Hua, Qingwang; Lin, Zhiyong; Hu, Xingti; Zhao, Qifeng

    2017-08-03

    Congenital abnormalities of the aortic arch include interrupted aortic arch (IAA), coarctation of the aorta (CoA), and double aortic arch (DAA). Aortic arch repair is difficult and postoperative complications are common. However, postoperative tracheobronchial stenosis with respiratory insufficiency is an uncommon complication and is usually caused by increased aortic anastomotic tension. We report here a case of tracheal compression by a mediastinal hematoma following IAA surgery. The patient underwent a repeat operation to remove the hematoma and was successfully weaned off the ventilator.In cases of tracheobronchial stenosis after aortic arch surgery, airway compression by increased aortic anastomotic tension is usually the first diagnosis considered by clinicians. Other causes, such as mediastinal hematomas, are often ignored. However, the severity of symptoms with mediastinal hematomas makes this an important entity.

  1. Influence of tip mass on dynamic behavior of cracked cantilever pipe conveying fluid with moving mass

    International Nuclear Information System (INIS)

    Yoon, Han Ik; Son, In Soo

    2005-01-01

    In this paper, we studied about the effect of the open crack and a tip mass on the dynamic behavior of a cantilever pipe conveying fluid with a moving mass. The equation of motion is derived by using Lagrange's equation and analyzed by numerical method. The cantilever pipe is modelled by the Euler-Bernoulli beam theory. The crack section is represented by a local flexibility matrix connecting two undamaged pipe segments. The influences of the crack, the moving mass, the tip mass and its moment of inertia, the velocity of fluid, and the coupling of these factors on the vibration mode, the frequency, and the tip-displacement of the cantilever pipe are analytically clarified

  2. Global consequences of a local Casimir force : Adhered cantilever

    NARCIS (Netherlands)

    Svetovoy, V. B.; Melenev, A. E.; Lokhanin, M. V.; Palasantzas, G.

    2017-01-01

    Although stiction is a cumbersome problem for microsystems, it stimulates investigations of surface adhesion. In fact, the shape of an adhered cantilever carries information of the adhesion energy that locks one end to the substrate. We demonstrate here that the system is also sensitive to the

  3. Recurrent neck infection with branchial arch fistula in children.

    Science.gov (United States)

    Madana, J; Yolmo, Deeke; Kalaiarasi, R; Gopalakrishnan, S; Saxena, S K; Krishnapriya, S

    2011-09-01

    Acute suppurative neck infections associated with third or fourth branchial arch fistulas are frequently recurrent. Third and fourth branchial arch anomalies are much less common than those of second arch and usually present with left thyroid lobe inflammation. The authors present their experience with 15 cases of pyriform sinus fistulae (PSF) of third branchial arch origin and 3 cases of fourth arch origin, all of which presented as recurrent neck infection mainly on the left side. A retrospective review of 18 cases of third and fourth arch fistulae treated at JIPMER from 2005 to 2010. This study includes 18 patients with PSF diagnosed by the existence of fistulous tract radiologically and intraoperatively with pathological correlation. Neck exploration with excision of tract and left hemithyroidectomy was performed in all cases. The patients consisted of 7 males and 11 females, and the ages ranged from 3 to 15 years. All of them presented with recurrent episodes of neck infection. Investigations performed include computed tomography (CT) fistulography, barium swallow and ultrasound which were useful in delineating pyriform sinus fistulous tract preoperatively. All cases were on the left side and the fistula was identified by barium swallow in 14 cases (80%), while intraoperative and pathologic confirmation of the tract was possible in all cases (100%). Neck exploration with an emphasis on complete exposure of the recurrent laryngeal nerve and exposure of the pyriform sinus opening to facilitate complete fistulous tract excision with left hemithyroidectomy was successful in all patients. A follow up period of 1-3 years showed no recurrence. Recurrent neck infection in a child should alert the physician to the possibility of an underlying pyriform sinus fistula of branchial origin and CT fistulography should be performed after the resolution of the neck infection to delineate the tract anatomically. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All

  4. Three-dimensional finite element analysis of different implant configurations for a mandibular fixed prosthesis.

    Science.gov (United States)

    Fazi, Giovanni; Tellini, Simone; Vangi, Dario; Branchi, Roberto

    2011-01-01

    The distribution of stresses in bone, implants, and prosthesis were analyzed via three-dimensional finite element modeling in different implant configurations for a fixed implant-supported prosthesis in an edentulous mandible. A finite element model was created with data obtained from computed tomographic scans of a human mandible. Anisotropic characteristics for cortical and cancellous bone were incorporated into the model. Six different configurations of intraforaminal implants were tested, with the number of implants varying from three to five and the distal implants inserted either parallel to the other implants or tilted distally by 17 or 34 degrees. A prosthetic structure connecting the implants was designed, with 20-mm posterior cantilevers for the parallel implant configurations, and a load of 200 N was applied to the distal portion of the cantilevers. Stresses were measured at the level of the implant, the prosthetic structure, and the bone. Bone-level stresses were analyzed at the implant-bone interface, at the external cortical bone surface, distal to the terminal implant, and in the cancellous bone along the implant body. A three-parallel-implant configuration resulted in higher stress in the implant and bone than configurations with four or five parallel implants. Configurations with the distal implants tilted resulted in a more favorable stress distribution at all levels. In parallel-implant configurations for fixed implant-supported mandibular prostheses, four and five implants resulted in similar stress distribution in the bone, framework, and implants. A distribution of four implants with the distal implants tilted 34 degrees (ie, the "All-on-Four" configuration) resulted in a favorable reduction of stresses in the bone, framework, and implants.

  5. Effects of Asthma and Inhalation corticosteroids on the dental arch morphology in children

    Directory of Open Access Journals (Sweden)

    S S Kumar

    2012-01-01

    Full Text Available Background: Hereditary, environmental and developmental factors play an important role in dentofacial development, as well as the initiation of malocclusion disorder. Allergic phenomenon such as asthma that induces an alternative mode of breathing in patients is a contributing factor in development of the dental arch. Aim: Our aim in this study was to evaluate the dentoalveolar morphology in asthmatic children and to analyze the effects of asthmatic medications on the dental arch. Setting and Design : This study is centered on 44 asthmatic children aged between 6-12 years from J.S.S Hospital, Mysore. Selected variables from model analysis of the casts of the asthmatic group were subjected to comparison with those of the non-asthmatic group, which comprised of 44 non-asthmatic children. Selected parameters were arch width, arch length and palatal depth. Materials and Methods : Impressions of upper and lower arches were made with rubber based impression material. A sliding digital caliper was used to measure the casts for arch width and arch length. A palatal depth gauge was used to measure the palatal depth. Statistical Analysis : Differences in arch widths, arch lengths and palatal depths between asthmatics and non-asthmatics groups were evaluated by independent sample t-tests. Chi-square test was applied to assess the frequency of occurrence of malocclusion in the asthmatic children. Result: The results obtained revealed that the arch length and palatal depth of asthmatic group had higher values compared to that of non-asthmatic groups for both age groups (6 to 8-year-old males and females, 10 to 12-year-old males and females. Inter molar width showed a significant lower value in asthmatics in the maxillary arches of 10 to 12-year-old females. Fifty percent of the asthmatic children aged 10 to 12-years had open-bite. Children under regular medication showed significant deviation in the dentoalveolar morphology as compared to those under

  6. Complete-arch accuracy of intraoral scanners.

    Science.gov (United States)

    Treesh, Joshua C; Liacouras, Peter C; Taft, Robert M; Brooks, Daniel I; Raiciulescu, Sorana; Ellert, Daniel O; Grant, Gerald T; Ye, Ling

    2018-04-30

    Intraoral scanners have shown varied results in complete-arch applications. The purpose of this in vitro study was to evaluate the complete-arch accuracy of 4 intraoral scanners based on trueness and precision measurements compared with a known reference (trueness) and with each other (precision). Four intraoral scanners were evaluated: CEREC Bluecam, CEREC Omnicam, TRIOS Color, and Carestream CS 3500. A complete-arch reference cast was created and printed using a 3-dimensional dental cast printer with photopolymer resin. The reference cast was digitized using a laboratory-based white light 3-dimensional scanner. The printed reference cast was scanned 10 times with each intraoral scanner. The digital standard tessellation language (STL) files from each scanner were then registered to the reference file and compared with differences in trueness and precision using a 3-dimensional modeling software. Additionally, scanning time was recorded for each scan performed. The Wilcoxon signed rank, Kruskal-Wallis, and Dunn tests were used to detect differences for trueness, precision, and scanning time (α=.05). Carestream CS 3500 had the lowest overall trueness and precision compared with Bluecam and TRIOS Color. The fourth scanner, Omnicam, had intermediate trueness and precision. All of the scanners tended to underestimate the size of the reference file, with exception of the Carestream CS 3500, which was more variable. Based on visual inspection of the color rendering of signed differences, the greatest amount of error tended to be in the posterior aspects of the arch, with local errors exceeding 100 μm for all scans. The single capture scanner Carestream CS 3500 had the overall longest scan times and was significantly slower than the continuous capture scanners TRIOS Color and Omnicam. Significant differences in both trueness and precision were found among the scanners. Scan times of the continuous capture scanners were faster than the single capture scanners

  7. Evaluation of arch form between Vietnamese and North American Caucasians using 3-dimensional virtual models.

    Science.gov (United States)

    Trang, Vu Thi Thu; Park, Jae Hyun; Bayome, Mohamed; Shastry, Shruti; Mellion, Alex; Kook, Yoon-Ah

    2015-01-01

    The purpose of this study was to investigate the three-dimensional (3D) morphologic differences in the mandibular arch of Vietnamese and North American White subjects. The sample included 113 Vietnamese subjects (41 Class I, 37 Class II and 35 Class III) and 96 White subjects (29 Class I, 30 Class II and 37 Class III). The samples were regrouped according to arch form types (tapered, ovoid, and square) to compare the frequency distribution of the three arch forms between ethnic groups in each angle classification. The facial axis point of each tooth was digitized on 3D virtual models. Four linear and two ratio variables were measured. In comparing arch dimensions, the intercanine and intermolar widths were wider in Vietnamese than in Whites (p Vietnamese group, the square arch form was the most frequent followed by tapered and ovoid arch forms. The arch forms of Whites were narrower than Vietnamese. In North American Whites, the distribution of the arch form types showed similar frequency. In Vietnamese, the square arch form was more frequent.

  8. Computational analysis of the effect of surface roughness on the deflection of gold coated silicon micro-cantilevers due to molecular adsorption

    Science.gov (United States)

    Hayden, Victor

    In this work numerical simulations were performed in order to study the effects of surface roughness on the deflection of gold coated silicon cantilevers due to molecular adsorption. The cantilever was modeled using a ball and spring system where the spring constants for the Si-Si, Si-Au, and Au-Au bonds were obtained from first principal calculations. The molecular adsorption process was simulated by elongating the natural bond length at available bonding sites chosen randomly on the cantilever. Increasing the bond length created a surface stress on the cantilever causing it to deflect. In all cases the structure refinement was performed by minimizing the energy of the system using a simulated annealing algorithm and a high quality random number generator called Mersenne Twister. The system studied consisted of a 1 micrometer by 1 micrometer portion of a cantilever of various surface roughnesses with variable boundary condition and was processed in parallel on the ACEnet (Atlantic Computational Excellence Network) cluster. The results have indicated that cantilevers with a rougher gold surface deflected more than those with a smoother surface. The increase in deflection is attributed to an increase in stress raisers in the gold film localized around the surface features. The onset of stress raisers increases the differential stress between the top and bottom surfaces and results in an increase in the deflection of the cantilever.

  9. A Quad-Cantilevered Plate micro-sensor for intracranial pressure measurement.

    Science.gov (United States)

    Lalkov, Vasko; Qasaimeh, Mohammad A

    2017-07-01

    This paper proposes a new design for pressure-sensing micro-plate platform to bring higher sensitivity to a pressure sensor based on piezoresistive MEMS sensing mechanism. The proposed design is composed of a suspended plate having four stepped cantilever beams connected to its corners, and thus defined as Quad-Cantilevered Plate (QCP). Finite element analysis was performed to determine the optimal design for sensitivity and structural stability under a range of applied forces. Furthermore, a piezoresistive analysis was performed to calculate sensor sensitivity. Both the maximum stress and the change in resistance of the piezoresistor associated with the QCP were found to be higher compared to previously published designs, and linearly related to the applied pressure as desired. Therefore, the QCP demonstrates greater sensitivity, and could be potentially used as an efficient pressure sensor for intracranial pressure measurement.

  10. Experimental investigation of snap-through motion of in-plane MEMS shallow arches under electrostatic excitation

    KAUST Repository

    Ramini, Abdallah

    2015-12-11

    We present an experimental investigation for the nonlinear dynamic behaviors of clamped–clamped in-plane MEMS shallow arches when excited by harmonic electrostatic forces. Frequency sweeps are conducted to study the dynamic behaviors in the neighborhoods of the first and third resonance frequencies as well as the super-harmonic resonances. Experimental results show local softening behavior of small oscillations around the first resonance frequency and hardening behavior at the third resonance frequency for small dc and ac loads. Interesting dynamic snap-through cross-well motions are observed experimentally at high voltages for the first time in the micro-scale world. In addition to the dynamic snap-through motion, the MEMS arch exhibits large oscillations of a continuous band of snap-through motion between the super-harmonic resonance regime and the first primary resonance regime. This continuous band is unprecedented experimentally in the micro/macro world, and is promising for a variety of sensing, actuation and communications applications.

  11. Experimental investigation of snap-through motion of in-plane MEMS shallow arches under electrostatic excitation

    KAUST Repository

    Ramini, Abdallah; Bellaredj, Mohammed L F; Al Hafiz, Md Abdullah; Younis, Mohammad I.

    2015-01-01

    We present an experimental investigation for the nonlinear dynamic behaviors of clamped–clamped in-plane MEMS shallow arches when excited by harmonic electrostatic forces. Frequency sweeps are conducted to study the dynamic behaviors in the neighborhoods of the first and third resonance frequencies as well as the super-harmonic resonances. Experimental results show local softening behavior of small oscillations around the first resonance frequency and hardening behavior at the third resonance frequency for small dc and ac loads. Interesting dynamic snap-through cross-well motions are observed experimentally at high voltages for the first time in the micro-scale world. In addition to the dynamic snap-through motion, the MEMS arch exhibits large oscillations of a continuous band of snap-through motion between the super-harmonic resonance regime and the first primary resonance regime. This continuous band is unprecedented experimentally in the micro/macro world, and is promising for a variety of sensing, actuation and communications applications.

  12. Optical silencing of C. elegans cells with arch proton pump.

    Directory of Open Access Journals (Sweden)

    Ayako Okazaki

    Full Text Available BACKGROUND: Optogenetic techniques using light-driven ion channels or ion pumps for controlling excitable cells have greatly facilitated the investigation of nervous systems in vivo. A model organism, C. elegans, with its small transparent body and well-characterized neural circuits, is especially suitable for optogenetic analyses. METHODOLOGY/PRINCIPAL FINDINGS: We describe the application of archaerhodopsin-3 (Arch, a recently reported optical neuronal silencer, to C. elegans. Arch::GFP expressed either in all neurons or body wall muscles of the entire body by means of transgenes were localized, at least partially, to the cell membrane without adverse effects, and caused locomotory paralysis of worms when illuminated by green light (550 nm. Pan-neuronal expression of Arch endowed worms with quick and sustained responsiveness to such light. Worms reliably responded to repeated periods of illumination and non-illumination, and remained paralyzed under continuous illumination for 30 seconds. Worms expressing Arch in different subsets of motor neurons exhibited distinct defects in the locomotory behavior under green light: selective silencing of A-type motor neurons affected backward movement while silencing of B-type motor neurons affected forward movement more severely. Our experiments using a heat-shock-mediated induction system also indicate that Arch becomes fully functional only 12 hours after induction and remains functional for more than 24 hour. CONCLUSIONS/SGNIFICANCE: Arch can be used for silencing neurons and muscles, and may be a useful alternative to currently widely used halorhodopsin (NpHR in optogenetic studies of C. elegans.

  13. Use of thermal cycling to reduce adhesion of OTS coated coated MEMS cantilevers

    Science.gov (United States)

    Ali, Shaikh M.; Phinney, Leslie M.

    2003-01-01

    °Microelectromechanical systems (MEMS) have enormous potential to contribute in diverse fields such as automotive, health care, aerospace, consumer products, and biotechnology, but successful commercial applications of MEMS are still small in number. Reliability of MEMS is a major impediment to the commercialization of laboratory prototypes. Due to the multitude of MEMS applications and the numerous processing and packaging steps, MEMS are exposed to a variety of environmental conditions, making the prediction of operational reliability difficult. In this paper, we investigate the effects of operating temperature on the in-use adhesive failure of electrostatically actuated MEMS microcantilevers coated with octadecyltrichlorosilane (OTS) films. The cantilevers are subjected to repeated temperature cycles and electrostatically actuated at temperatures between 25°C and 300°C in ambient air. The experimental results indicate that temperature cycling of the OTS coated cantilevers in air reduces the sticking probability of the microcantilevers. The sticking probability of OTS coated cantilevers was highest during heating, which decreased during cooling, and was lowest during reheating. Modifications to the OTS release method to increase its yield are also discussed.

  14. Hybrid treatment of aortic arch disease

    Science.gov (United States)

    Metzger, Patrick Bastos; Rossi, Fabio Henrique; Moreira, Samuel Martins; Issa, Mario; Izukawa, Nilo Mitsuru; Dinkhuysen, Jarbas J.; Spina Neto, Domingos; Kambara, Antônio Massamitsu

    2014-01-01

    Introduction The management of thoracic aortic disease involving the ascending aorta, aortic arch and descending thoracic aorta are technically challenging and is an area in constant development and innovation. Objective To analyze early and midterm results of hybrid treatment of arch aortic disease. Methods Retrospective study of procedures performed from January 2010 to December 2012. The end points were the technical success, therapeutic success, morbidity and mortality, neurologic outcomes, the rate of endoleaks and reinterventions. Results A total of 95 patients treated for thoracic aortic diseases in this period, 18 underwent hybrid treatment and entered in this study. The average ages were 62.3 years. The male was present in 66.7%. The technical and therapeutic success was 94.5% e 83.3%. The perioperative mortality rate of 11.1%. There is any death during one-year follow- up. The reoperation rates were 16.6% due 2 cases of endoleak Ia and one case of endoleak II. There is any occlusion of anatomic or extra anatomic bypass during follow up. Conclusion In our study, the hybrid treatment of aortic arch disease proved to be a feasible alternative of conventional surgery. The therapeutic success rates and re- interventions obtained demonstrate the necessity of thorough clinical follow-up of these patients in a long time. PMID:25714205

  15. Structural behaviour of masonry arch with no-horizontal springing settlement

    Directory of Open Access Journals (Sweden)

    P. Zampieri

    2018-01-01

    Full Text Available This paper presents a calculation procedure for assessing the structural integrity of a masonry arch with non-horizontal springing settlement. By applying the Principle of Virtual Work (PVW to the deformed arch system, the procedure proposed herein details the reaction forces and thrust lines for each step of imposed settlement of the support. The procedure can also be used estimate the final displacement that causes complete failure of arch structural capacity. The results of the analysis procedure were compared against those obtained by experimental testing so as to validate the proposed calculation method

  16. Technical improvement of arch setting machine for roadway drive. Kusshin kirihayo sewakuki no hensen

    Energy Technology Data Exchange (ETDEWEB)

    Fujino, T [Taiheiyo Coal Mining Co. Ltd., Tokyo (Japan)

    1991-09-25

    The following contents are described for a new type arch setting machine introduced to the Taiheiyo Coal Mining Co. (1) The excavation of drift in this coal mine is carried out by the excavating system combining the excavating machine (CM) and the transporter (SC) and the supporting method where arch type steel beams are used as the supporting material is used. (2) In order to automatize the arch setting work, this machine which combined the both functions of the arch lifter (developed in 1983) and the arch setting manipulator (ASM, developed in 1990). (3) This machine has the total weight of 1,500kg, is mounted on CM, and consists of the running part, the arm part, the boom part, and the end saucer part of steel arches. Further, simple fitting or removing can be made and the coal falling down is prevented by holding the coal wall during the arch setting work. (4) When this machine and the ASM were compared for the arch setting time in the working site, the former required about the half time period of the latter. 5 figs., 1 tab.

  17. Ductal Stent Implantation in Tetralogy of Fallot with Aortic Arch Abnormality

    Science.gov (United States)

    Ergul, Yakup; Saygi, Murat; Ozyilmaz, Isa; Guzeltas, Alper; Odemis, Ender

    2015-01-01

    Stenting of patent ductus arteriosus is an alternative to palliative cardiac surgery in newborns with duct-dependent or decreased pulmonary circulation; however, the use of this technique in patients with an aortic arch abnormality presents a challenge. Tetralogy of Fallot is a congenital heart defect that is frequently associated with anomalies of the aortic arch and its branches. The association is even more common in patients with chromosome 22q11 deletion. We present the case of an 18-day-old male infant who had cyanosis and a heart murmur. After an initial echocardiographic evaluation, the patient was diagnosed with tetralogy of Fallot and right-sided aortic arch. The pulmonary annulus and the main pulmonary artery and its branches were slightly hypoplastic; the ductus arteriosus was small. Conventional and computed tomographic angiograms revealed a double aortic arch and an aberrant left subclavian artery. The right aortic arch branched into the subclavian arteries and continued into the descending aorta, whereas the left aortic arch branched into the common carotid arteries and ended with the patent ductus arteriosus. After evaluation of the ductal anatomy, we implanted a 3.5 × 15-mm coronary stent in the duct. Follow-up injections showed augmented pulmonary flow and an increase in oxygen saturation from 65% to 94%. The patient was also found to have chromosome 22q11 deletion. PMID:26175649

  18. High-speed imaging upgrade for a standard sample scanning atomic force microscope using small cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Jonathan D.; Nievergelt, Adrian; Erickson, Blake W.; Yang, Chen; Dukic, Maja; Fantner, Georg E., E-mail: georg.fantner@epfl.ch [Ecole Polytechnique Fédérale de Lausanne, Lausanne (Switzerland)

    2014-09-15

    We present an atomic force microscope (AFM) head for optical beam deflection on small cantilevers. Our AFM head is designed to be small in size, easily integrated into a commercial AFM system, and has a modular architecture facilitating exchange of the optical and electronic assemblies. We present two different designs for both the optical beam deflection and the electronic readout systems, and evaluate their performance. Using small cantilevers with our AFM head on an otherwise unmodified commercial AFM system, we are able to take tapping mode images approximately 5–10 times faster compared to the same AFM system using large cantilevers. By using additional scanner turnaround resonance compensation and a controller designed for high-speed AFM imaging, we show tapping mode imaging of lipid bilayers at line scan rates of 100–500 Hz for scan areas of several micrometers in size.

  19. Full-scale load tests of Pearl-Chain arches

    DEFF Research Database (Denmark)

    Halding, Philip Skov; Hertz, Kristian Dahl; Schmidt, Jacob Wittrup

    2017-01-01

    -Decks: First an investigation of the system’s elastic response (maximum load of 648kN), and second a demonstration of its collapse mechanism and ultimate capacity (maximum load of 970kN). The full-scale test showed formation of plastic hinges and clear warning signs are observed at 84% of the failure load......A full-scale load test is made of two Pearl-Chain (PC) concrete arches in order to evaluate the structural response and assess the design safety. Pearl-Chain structures and Pearl-Chain arches are invented and patented at the Technical University of Denmark. PC-Arches consist of specially designed....... The ultimate, experimental load capacity is 14% higher than the calculated mainly due to the assumed static system used for the calculation. In addition to the full-scale test bridge the first ever permanent PC-Bridge is erected in Denmark in 2015....

  20. In-Plane MEMS Shallow Arch Beam for Mechanical Memory

    KAUST Repository

    Hafiz, Md Abdullah Al; Kosuru, Lakshmoji; Ramini, Abdallah; Chappanda, Karumbaiah N.; Younis, Mohammad I.

    2016-01-01

    We demonstrate a memory device based on the nonlinear dynamics of an in-plane microelectromechanical systems (MEMS) clamped–clamped beam resonator, which is deliberately fabricated as a shallow arch. The arch beam is made of silicon, and is electrostatically actuated. The concept relies on the inherent quadratic nonlinearity originating from the arch curvature, which results in a softening behavior that creates hysteresis and co-existing states of motion. Since it is independent of the electrostatic force, this nonlinearity gives more flexibility in the operating conditions and allows for lower actuation voltages. Experimental results are generated through electrical characterization setup. Results are shown demonstrating the switching between the two vibrational states with the change of the direct current (DC) bias voltage, thereby proving the memory concept.

  1. In-Plane MEMS Shallow Arch Beam for Mechanical Memory

    KAUST Repository

    Hafiz, Md Abdullah Al

    2016-10-18

    We demonstrate a memory device based on the nonlinear dynamics of an in-plane microelectromechanical systems (MEMS) clamped–clamped beam resonator, which is deliberately fabricated as a shallow arch. The arch beam is made of silicon, and is electrostatically actuated. The concept relies on the inherent quadratic nonlinearity originating from the arch curvature, which results in a softening behavior that creates hysteresis and co-existing states of motion. Since it is independent of the electrostatic force, this nonlinearity gives more flexibility in the operating conditions and allows for lower actuation voltages. Experimental results are generated through electrical characterization setup. Results are shown demonstrating the switching between the two vibrational states with the change of the direct current (DC) bias voltage, thereby proving the memory concept.

  2. Assessment of the influence of jogging on the shape of female foot arches.

    Science.gov (United States)

    Maslon, Agata; Golec, Joanna; Szczygiel, Elzbieta; Czechowska, Dorota; Golec, Boguslaw

    2017-12-23

    Both walking and its faster, running, consist of cyclical subsequent phases of swing and support; however, they differ in their time proportions as well as magnitude of acting forces. There is a lack of studies concerning the long-term consequences of repeated jogging cycles on the function of feet and, above all, on their permanent impact on the shape of foot arches. The objective of this study was to answer the question whether regular jogging changes the shape of the transverse and medial longitudinal arches of the feet. The research material consisted of 96 women with an average age of 26.57, and included 50 actively jogging women, and 46 of non-joggers. The study was performed with the use of EMED-SF force platform. The plantar surface of the foot was divided into 10 regions according to Cavanagh, for which peak pressure and contact time were established. Two indicators were defined: metatarsal bone pressure distribution pattern acc. to Kantali, and longitudinal arch index acc. to Cavanagh. The data obtained revealed more frequent occurrence of the greatest pressure under the centrally located metatarsal heads (lack of functional foot transverse arch) among the female joggers, compared with the non-joggers. Moreover, the findings indicate the higher frequency of medial longitudinal foot arch flattening among female runners, with a great deal of consistency between both feet, whereas results for the control group show asymmetrical medial arch shapes with right foot propensity to normal arch shape and left foot tendency for excessive arch. The observed differences in feet arch shapes between female joggers and non-joggers indicate the influence of jogging on feet functional adaptations.

  3. In silico modeling and investigation of self-heating effects in composite nano cantilever biosensors with integrated piezoresistors

    Directory of Open Access Journals (Sweden)

    Ribu Mathew

    2017-03-01

    Full Text Available Over the years, piezoresistive nano cantilever sensors have been extensively investigated for various biological sensing applications. Piezoresistive cantilever sensor is a composite structure with different materials constituting its various layers. Design and modeling of such sensors become challenging since their response is governed by the interplay between their geometrical and constituent material parameters. Even though, piezoresistive nano cantilever biosensors have several advantages, they suffer from a limitation in the form of self-heating induced inaccuracy which is seldom considered in design stages. Although, a few simplified mathematical models have been reported which incorporate the self-heating effect, several assumptions made in the modeling stages result in inaccuracy in predicting sensor terminal response. In this paper, we model and investigate the effect of self-heating on the thermo-electro-mechanical response of piezoresistive cantilever sensors as a function of the relative geometries of the piezoresistor and the cantilever platform. Finite element method (FEM based numerical computations are used to model the target-receptor interactions induced surface stress response in steady state and maximize the electrical sensitivity to thermal sensitivity ratio of the sensor. Simulation results show that the conduction mode of heat transfer is the dominant heat transfer mechanism. Furthermore, the isolation and immobilization layers play a critical role in determining the thermal sensitivity of the sensor. It is found that the shorter and wider cantilever platforms are more suitable to reduce self-heating induced inaccuracies. In addition, results depict that the piezoresistor width plays a more dominant role in determining the thermal drift induced inaccuracies compared to the piezoresistor length. It is found that for surface stress sensors at large piezoresistor width, the electrical sensitivity to thermal sensitivity ratio

  4. The effect of impression volume and double-arch trays on the registration of maximum intercuspation.

    Science.gov (United States)

    Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F

    2009-12-01

    The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (Precord making.

  5. Highly tunable NEMS shallow arches

    KAUST Repository

    Kazmi, Syed N. R.; Hajjaj, Amal Z.; Da Costa, Pedro M. F. J.; Younis, Mohammad I.

    2017-01-01

    and surface nanomachining of a highly conductive device layer on a silicon-on-insulator wafer. By designing the structures to have gap to thickness ratio of more than four, the mid-plane stretching of the nano arches is maximized such that an increase

  6. Electrostatically Tunable Nanomechanical Shallow Arches

    KAUST Repository

    Kazmi, Syed N. R.; Hajjaj, Amal Z.; Da Costa, Pedro M. F. J.; Younis, Mohammad I.

    2017-01-01

    -beam lithography and surface nanomachining of a highly conductive device layer on a silicon-on-insulator (SOI) wafer. The experimental results show good agreement with the analytical results with a maximum tunability of 108.14% for 180 nm thick arch with a

  7. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    Science.gov (United States)

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Microelectromechanical system device for calibration of atomic force microscope cantilever spring constants between 0.01 and 4 N/m

    International Nuclear Information System (INIS)

    Cumpson, Peter J.; Hedley, John; Clifford, Charles A.; Chen Xinyong; Allen, Stephanie

    2004-01-01

    Calibration of atomic force microscope (AFM) cantilevers is necessary for the measurement of nano-newton and pico-newton forces, which are critical to analytical application of AFM in the analysis of polymer surfaces, biological structures and organic molecules. Previously we have described microfabricated array of reference spring (MARS) devices for AFM cantilever spring-constant calibration. Hitherto, these have been limited to the calibration of AFM cantilevers above 0.03 N/m, although they can be used to calibrate cantilevers of lower stiffness with reduced accuracy. Below this limit MARS devices similar to the designs hitherto described would be fragile and difficult to manufacture with reasonable yield. In this work we describe a device we call torsional MARS. This is a large-area torsional mechanical resonator, manufactured by bulk micromachining of a 'silicon-on-insulator' wafer. By measuring its torsional oscillation accurately in vacuum we can deduce its torsional spring constant. The torsional reference spring spans the range of spring constant (from 4 down to 0.01 N/m) that is important in biological AFM, allowing even the most compliant AFM cantilever to be calibrated easily and rapidly

  9. Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking.

    Science.gov (United States)

    Kim, Jun Sik; Park, Young Ji; Lee, Yoon Jung; Kim, Nam Gyun; Lee, Kyung Suk

    2016-12-01

    Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

  10. Influence of silicon orientation and cantilever undercut on the determination of the Young’s modulus of thin films

    NARCIS (Netherlands)

    Nazeer, H.; Woldering, L.A.; Abelmann, Leon; Nguyen, Duc Minh; Rijnders, Augustinus J.H.M.; Elwenspoek, Michael Curt

    The Young’s modulus of thin films can be determined by deposition on a micronsized Si cantilever and measuring the resonance frequency before and after deposition. The accuracy of the method depends strongly on the initial determination of the mechanical properties and dimensions of the cantilever.

  11. A Novel Approach to the Sensing of Liquid Density Using a Plastic Optical Fibre Cantilever Beam

    Science.gov (United States)

    Kulkarni, Atul; Kim, Youngjin; Kim, Taesung

    2009-01-01

    This article reports for the first time the use of a plastic optical fibre (POF) cantilever beam to measure the density of a liquid. The sensor is based on the Archimedes buoyancy principle. The sensor consists of a POF bonded on the surface of a metal beam in the form of a cantilever configuration, and at the free end of the beam a displacer is…

  12. Hemiarch versus total aortic arch replacement in acute type A dissection: a systematic review and meta-analysis.

    Science.gov (United States)

    Poon, Shi Sum; Theologou, Thomas; Harrington, Deborah; Kuduvalli, Manoj; Oo, Aung; Field, Mark

    2016-05-01

    Despite recent advances in aortic surgery, acute type A aortic dissection remains a surgical emergency associated with high mortality and morbidity. Appropriate management is crucial to achieve satisfactory outcomes but the optimal surgical approach is controversial. The present systematic review and meta-analysis sought to access cumulative data from comparative studies between hemiarch and total aortic arch replacement in patients with acute type A aortic dissection. A systematic review of the literature using six databases. Eligible studies include comparative studies on hemiarch versus total arch replacement reporting short, medium and long term outcomes. A meta-analysis was performed on eligible studies reporting outcome of interest to quantify the effects of hemiarch replacement on mortality and morbidity risk compared to total arch replacement. Fourteen retrospective studies met the inclusion criteria and 2,221 patients were included in the final analysis. Pooled analysis showed that hemiarch replacement was associated with a lower risk of post-operative renal dialysis [risk ratio (RR) =0.72; 95% confidence interval (CI): 0.56-0.94; P=0.02; I(2)=0%]. There was no significant difference in terms of in-hospital mortality between the two groups (RR =0.84; 95% CI: 0.65-1.09; P=0.20; I(2)=0%). Cardiopulmonary bypass, aortic cross clamp and circulatory arrest times were significantly longer in total arch replacement. During follow up, no significant difference was reported from current studies between the two operative approaches in terms of aortic re-intervention and freedom from aortic reoperation. Within the context of publication bias by high volume aortic centres and non-randomized data sets, there was no difference in mortality outcomes between the two groups. This analysis serves to demonstrate that for those centers doing sufficient total aortic arch activity to allow for publication, excellent and equivalent outcomes are achievable. Conclusions on

  13. Enhanced quality factors and force sensitivity by attaching magnetic beads to cantilevers for atomic force microscopy in liquid

    Science.gov (United States)

    Hoof, Sebastian; Nand Gosvami, Nitya; Hoogenboom, Bart W.

    2012-12-01

    Dynamic-mode atomic force microscopy (AFM) in liquid remains complicated due to the strong viscous damping of the cantilever resonance. Here, we show that a high-quality resonance (Q >20) can be achieved in aqueous solution by attaching a microgram-bead at the end of the nanogram-cantilever. The resulting increase in cantilever mass causes the resonance frequency to drop significantly. However, the force sensitivity—as expressed via the minimum detectable force gradient—is hardly affected, because of the enhanced quality factor. Through the enhancement of the quality factor, the attached bead also reduces the relative importance of noise in the deflection detector. It can thus yield an improved signal-to-noise ratio when this detector noise is significant. We describe and analyze these effects for a set-up that includes magnetic actuation of the cantilevers and that can be easily implemented in any AFM system that is compatible with an inverted optical microscope.

  14. Readout of micromechanical cantilever sensor arrays by Fabry-Perot interferometry

    International Nuclear Information System (INIS)

    Wehrmeister, Jana; Fuss, Achim; Saurenbach, Frank; Berger, Ruediger; Helm, Mark

    2007-01-01

    The increasing use of micromechanical cantilevers in sensing applications causes a need for reliable readout techniques of micromechanical cantilever sensor (MCS) bending. Current optical beam deflection techniques suffer from drawbacks such as artifacts due to changes in the refraction index upon exchange of media. Here, an adaptation of the Fabry-Perot interferometer is presented that allows simultaneous determination of MCS bending and changes in the refraction index of media. Calibration of the instrument with liquids of known refraction index provides an avenue to direct measurement of bending with nanometer precision. Versatile construction of flow cells in combination with alignment features for substrate chips allows simultaneous measurement of two MCS situated either on the same, or on two different support chips. The performance of the instrument is demonstrate in several sensing applications, including adsorption experiments of alkanethioles on MCS gold surfaces, and measurement of humidity changes in air

  15. Note: Determination of torsional spring constant of atomic force microscopy cantilevers: Combining normal spring constant and classical beam theory

    DEFF Research Database (Denmark)

    Álvarez-Asencio, R.; Thormann, Esben; Rutland, M.W.

    2013-01-01

    A technique has been developed for the calculation of torsional spring constants for AFM cantilevers based on the combination of the normal spring constant and plate/beam theory. It is easy to apply and allow the determination of torsional constants for stiff cantilevers where the thermal power s...... spectrum is difficult to obtain due to the high resonance frequency and low signal/noise ratio. The applicability is shown to be general and this simple approach can thus be used to obtain torsional constants for any beam shaped cantilever. © 2013 AIP Publishing LLC....

  16. Human evaluation in association to the mathematical analysis of arch forms: Two-dimensional study.

    Science.gov (United States)

    Zabidin, Nurwahidah; Mohamed, Alizae Marny; Zaharim, Azami; Marizan Nor, Murshida; Rosli, Tanti Irawati

    2018-03-01

    To evaluate the relationship between human evaluation of the dental-arch form, to complete a mathematical analysis via two different methods in quantifying the arch form, and to establish agreement with the fourth-order polynomial equation. This study included 64 sets of digitised maxilla and mandible dental casts obtained from a sample of dental arch with normal occlusion. For human evaluation, a convenient sample of orthodontic practitioners ranked the photo images of dental cast from the most tapered to the less tapered (square). In the mathematical analysis, dental arches were interpolated using the fourth-order polynomial equation with millimetric acetate paper and AutoCAD software. Finally, the relations between human evaluation and mathematical objective analyses were evaluated. Human evaluations were found to be generally in agreement, but only at the extremes of tapered and square arch forms; this indicated general human error and observer bias. The two methods used to plot the arch form were comparable. The use of fourth-order polynomial equation may be facilitative in obtaining a smooth curve, which can produce a template for individual arch that represents all potential tooth positions for the dental arch. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  17. Influence of shovel-shaped incisors on the dental arch crowding in Mongolian females.

    Science.gov (United States)

    Hasegawa, Yuh; Terada, Kazuto; Kageyama, Ikuo; Tsukada, Shin-ichi; Uzuka, Satoshi; Nakahara, Rizako; Nakahara, Sen

    2009-08-01

    The aim of this study was to investigate the influences of shovel-shaped incisors on the dental arch crowding in the samples of modern young female adult Mongolians (belonging to the Khalkha-Mogol grouping) ranged between 18.5 and 25.0 years, with a mean age of 20.7 years. Materials in this study comprised of 33 dental casts. Plaster replicas of the A.S.U. system plaques were used to facilitate standardization in scoring and classify shoveling regarding both upper central and lateral incisors. Dimensions of the dental arch namely, overjet, overbite, arch depth, arch width and irregularity index were measured. The correlation between the shovel shape of the central incisor and the lateral incisor was highly significant. Significantly relations were found between the grades of shoveling and the mesiodistal diameters of upper first molars and lower incisors. Positive correlation was admitted between the shoveling and upper arch depth anterior, and upper arch depth. It may be considered that the grades of shoveling are indirectly related with upper and/or lower anterior crowding. Although crowding is looks like an expression of disharmony between teeth and alveolar arch, it may be caused by multiple etiologic factors interacted directly and/or indirectly.

  18. Cantilever-based sensing: the origin of surface stress and optimization strategies

    International Nuclear Information System (INIS)

    Godin, Michel; Tabard-Cossa, Vincent; Miyahara, Yoichi; Grutter, Peter; Monga, Tanya; Bruce Lennox, R; Williams, P J; Beaulieu, L Y

    2010-01-01

    Many interactions drive the adsorption of molecules on surfaces, all of which can result in a measurable change in surface stress. This article compares the contributions of various possible interactions to the overall induced surface stress for cantilever-based sensing applications. The surface stress resulting from adsorption-induced changes in the electronic density of the underlying surface is up to 2-4 orders of magnitude larger than that resulting from intermolecular electrostatic or Lennard-Jones interactions. We reveal that the surface stress associated with the formation of high quality alkanethiol self-assembled monolayers on gold surfaces is independent of the molecular chain length, supporting our theoretical findings. This provides a foundation for the development of new strategies for increasing the sensitivity of cantilever-based sensors for various applications.

  19. Effects of pelvic rotation and needle angle on pubic arch interference during transperineal prostate implants

    International Nuclear Information System (INIS)

    Tincher, Sandra A.; Kim, Robert Y.; Ezekiel, Mark P.; Zinsli, Tom; Fiveash, John B.; Raben, David A.; Bueschen, Anton J.; Urban, Donald A.

    2000-01-01

    Purpose: Pubic arch interference due to an enlarged prostate gland or a narrow pubic arch is often a limiting factor in adequate prostate coverage during transperineal brachytherapy. The purpose of this study was to evaluate the effects of both pelvic rotation and needle angles on pubic arch interference using CT-based 3-D information. Methods and Materials: Seven patients had CT imaging in both supine and lithotomy positions and 3-D treatment planning was performed with three needle angles (20 downward, 0, 20 upward). The pubic arch interference was then measured and comparisons were made for each needle trajectory and pelvic position. Results: Increasing pelvic rotation from supine to lithotomy position shows less pubic arch interference. Directing the needle tip upward shows less pubic arch interference in both supine and lithotomy positions when compared to needle tips directed downward. Conclusions: Both pelvic position and needle angles are important factors influencing pubic arch interference. Preplanning CT-based 3-D information may assist for individualized treatment planning in patients with a significant bony interference, thus avoiding pubic arch interference during implantation

  20. Enhancing output power of a piezoelectric cantilever energy harvester using an oscillator

    International Nuclear Information System (INIS)

    Liu, Haili; Huang, Zhenyu; Xu, Tianzhu; Chen, Dayue

    2012-01-01

    The piezoelectric cantilever with a tip mass (Mass-PC), as a conventional vibration energy harvester, usually works at its fundamental frequency matching ambient excitation. By attaching an oscillator to a piezoelectric cantilever (Osc-PC), a double-mode energy harvester is developed to harvest more power from two matched ambient driving frequencies. Meanwhile, it allows the first operating frequency of the Osc-PC to be adjusted to be very low with only a limited mass attached. A distributed-parameter model of this harvester and the explicit expressions of its operating frequencies are derived to analyze and design the Osc-PC. Numerical investigations reveal that a heaver oscillator placed near the clamped end of the piezoelectric cantilever has better performance at the given exciting frequencies. Following the specified design criteria, an Osc-PC whose operating frequencies match two given exciting frequencies was constructed for the purpose of experimental testing. The results show that, compared to that of a corresponding Mass-PC whose operating frequency matches the lower exciting frequency, the energy harvesting efficiency of the Osc-PC increases by almost four times at the first operating frequency, while the output power at the second operating frequency of the Osc-PC accounts for 68% of that of the Mass-PC. (paper)

  1. Arched abdominal aorta and altered course of right ovarian vessels in a female cadaver: Clinical significance and embryological explanation

    Directory of Open Access Journals (Sweden)

    Sneha Guruprasad Kalthur

    2013-01-01

    Full Text Available Variations in the vascular origin of ovarian artery have been reported in the past. However, the reports on altered course of ovarian artery are very few. In the present paper, we discuss about multiple variations observed in formalin fixed female cadaver. The right ovarian artery was 22 cm long and ran unusually behind the inferior vena cava (IVC. The right ovarian vein drained in to right renal vein at right angle instead of draining into IVC directly. In addition, to these variations, the cadaver had arched abdominal aorta and retro-aortic left renal vein.

  2. Strategy Guideline: Quality Management in Existing Homes - Cantilever Floor Example

    Energy Technology Data Exchange (ETDEWEB)

    Taggart, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Sikora, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Wiehagen, J. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Wood, A. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2011-12-01

    This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented.

  3. Design optimization and fatigue testing of an electronically-driven mechanically-resonant cantilever spring mechanism

    International Nuclear Information System (INIS)

    Kheng, Lim Boon; Kean, Koay Loke; Gitano-Briggs, Horizon

    2010-01-01

    A light scanning device consisting of an electronically-driven mechanically-resonant cantilever spring-mirror system has been developed for innovative lighting applications. The repeated flexing of the cantilever spring during operation can lead to premature fatigue failure. A model was created to optimize the spring design. The optimized spring design can reduce stress by approximately one-third from the initial design. Fatigue testing showed that the optimized spring design can operate continuously for over 1 month without failure. Analysis of failures indicates surface cracks near the root of the spring are responsible for the failures.

  4. Multi-detector row computed tomographic evaluation of a rare type of complete vascular ring: Double aortic arch with atretic left arch distal to the origin of left subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Ying Ying; Fu, Ching Yun; Wei, Hao Ji; Tsai, I Chen; Chen, Clayton Chi Chang [Taichung Veterans General Hospital, Taichung (China)

    2013-10-15

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  5. The surgical importance of an axillary arch in sentinel node biopsy.

    LENUS (Irish Health Repository)

    Ridgway, P F

    2011-03-01

    When Carl Langer described the aberrant axillary arch in 1846 its relevance in sentinel node biopsy (SNB) surgery could not have been contemplated. The authors define an incidence and elucidate relevance of the arch in SNB of the axilla.

  6. Influence of silicon orientation and cantilever undercut on the determination of Young's modulus of pulsed laser deposited PZT

    NARCIS (Netherlands)

    Nazeer, H.; Woldering, L.A.; Abelmann, Leon; Nguyen, Duc Minh; Rijnders, Augustinus J.H.M.; Elwenspoek, Michael Curt

    In this work we show for the first time that the effective in-plane Young’s modulus of PbZr0.52Ti0.48O3 (PZT) thin films, deposited by pulsed laser deposition (PLD) on dedicated single crystal silicon cantilevers, is independent of the in-plane orientation of cantilevers.

  7. Piezoelectric Bimorph Cantilever for Vibration-Producing-Hydrogen

    Directory of Open Access Journals (Sweden)

    Guangming Cheng

    2012-12-01

    Full Text Available A device composed of a piezoelectric bimorph cantilever and a water electrolysis device was fabricated to realize piezoelectrochemical hydrogen production. The obvious output of the hydrogen and oxygen through application of a mechanical vibration of ~0.07 N and ~46.2 Hz was observed. This method provides a cost-effective, recyclable, environment-friendly and simple way to directly split water for hydrogen fuels by scavenging mechanical waste energy forms such as noise or traffic vibration in the environment.

  8. Orthodontic Traction of Impacted Canine Using Cantilever

    OpenAIRE

    Nakandakari, Cláudia; Gonçalves, João Roberto; Cassano, Daniel Serra; Raveli, Taísa Boamorte; Bianchi, Jonas; Raveli, Dirceu Barnabé

    2016-01-01

    The impaction of the maxillary canines causes relevant aesthetic and functional problems. The multidisciplinary approach to the proper planning and execution of orthodontic traction of the element in question is essential. Many strategies are cited in the literature; among them is the good biomechanical control in order to avoid possible side effects. The aim of this paper is to present a case report in which a superior canine impacted by palatine was pulled out with the aid of the cantilever...

  9. Parascapular mass revealing primary tuberculosis of the posterior arch

    Science.gov (United States)

    Arbault, Anais; Ornetti, Paul; Chevallier, Olivier; Avril, Julien; Pottecher, Pierre

    2016-01-01

    We report the case of a parascapular abscess revealing primary tuberculosis of the posterior arch in a 31-year-old man. Sectional imaging is essential in order to detect the different lesions of this atypical spinal tuberculosis as osteolysis of the posterior arch extendible to vertebral body, osteocondensation, epidural extension which is common in this location, and high specificity of a zygapophysial, costo-vertebral or transverse arthritis. PMID:27709081

  10. Label-free glucose detection using cantilever sensor technology based on gravimetric detection principles.

    Science.gov (United States)

    Hsieh, Shuchen; Hsieh, Shu-Ling; Hsieh, Chiung-Wen; Lin, Po-Chiao; Wu, Chun-Hsin

    2013-01-01

    Efficient maintenance of glucose homeostasis is a major challenge in diabetes therapy, where accurate and reliable glucose level detection is required. Though several methods are currently used, these suffer from impaired response and often unpredictable drift, making them unsuitable for long-term therapeutic practice. In this study, we demonstrate a method that uses a functionalized atomic force microscope (AFM) cantilever as the sensor for reliable glucose detection with sufficient sensitivity and selectivity for clinical use. We first modified the AFM tip with aminopropylsilatrane (APS) and then adsorbed glucose-specific lectin concanavalin A (Con A) onto the surface. The Con A/APS-modified probes were then used to detect glucose by monitoring shifts in the cantilever resonance frequency. To confirm the molecule-specific interaction, AFM topographical images were acquired of identically treated silicon substrates which indicated a specific attachment for glucose-Con A and not for galactose-Con A. These results demonstrate that by monitoring the frequency shift of the AFM cantilever, this sensing system can detect the interaction between Con A and glucose, one of the biomolecule recognition processes, and may assist in the detection and mass quantification of glucose for clinical applications with very high sensitivity.

  11. Botulinum Toxin Type A as Preoperative Treatment for Immediately Loaded Dental Implants Placed in Fresh Extraction Sockets for Full-Arch Restoration of Patients With Bruxism.

    Science.gov (United States)

    Mijiritsky, Eitan; Mortellaro, Carmen; Rudberg, Omri; Fahn, Miri; Basegmez, Cansu; Levin, Liran

    2016-05-01

    The aim of the present report was to describe the use of Botulinum toxin type A as preoperative treatment for immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration of patients with bruxism. Patients with bruxism who were scheduled to receive immediately loaded full-arch implant supported fixed restorations were included in this retrospective clinical report. To reduce the occlusal forces applied in patients with bruxism, Botulinum toxin type A was introduced prior to the implant placement procedure. Patients were followed and implant survival as well as peri-implant bone level was assessed in each periodic follow-up visit. Adverse effects were also recorded. A control group with no use of Botulinum toxin was evaluated as well. A total of 26 patients (13 test and 13 control), with bruxism, aged 59.15 ± 11.43 years on average were included in this retrospective report and received immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration. The test group treatment preceded by Botulinum toxin type A injection. Maxillary arches were supported by 8 to 10 implants while the mandibular arch was supported by 6 implants. All surgeries went uneventfully and no adverse effects were observed. The average follow-up time was 32.5 ± 10.4 months (range, 18-51). In the test group, no implant failures were recorded. One patient presented with 1 to 2 mm bone loss around 4 of the implants; the other implants presented with stable bone level. In the control group 1 patient lost 2 implants and another demonstrated 2 mm bone loss around 3 of the implants. The preoperative use of Botulinum toxin in patients with bruxism undergoing full-arch rehabilitation using immediately loaded dental implants placed in fresh extraction sockets seems to be a technique that deserves attention. Further long-term, large-scale randomized clinical trials will help to determine the additional benefit of this suggested

  12. Contemporary results of surgical repair of recurrent aortic arch obstruction.

    Science.gov (United States)

    Mery, Carlos M; Khan, Muhammad S; Guzmán-Pruneda, Francisco A; Verm, Raymond; Umakanthan, Ramanan; Watrin, Carmen H; Adachi, Iki; Heinle, Jeffrey S; McKenzie, E Dean; Fraser, Charles D

    2014-07-01

    There is a paucity of data on the current outcomes of surgical intervention for recurrent aortic arch obstruction (RAAO) after initial aortic arch repair in children. The goal of this study is to report the long-term results in these patients. All patients undergoing surgical intervention for RAAO at Texas Children's Hospital from 1995 to 2012 were included. The cohort was divided into four groups based on initial procedure: (1) simple coarctation repair, (2) Norwood procedure, (3) complex congenital heart disease, and (4) interrupted aortic arch. A total of 48 patients age 9 months (range, 22 days to 36 years) underwent 49 procedures for RAAO. All patients had an anatomic repair consisting of either patch aortoplasty (n=27, 55%), aortic arch advancement (n=8, 16%), sliding arch aortoplasty (n=6, 12%), placement of an interposition graft (n=2, 17%), reconstruction with donor allograft (n=4, 8%), extended end-to-end anastomosis (n=1, 2%), or redo Norwood-type reconstruction (n=1, 2%). Most procedures (n=46, 94%) were performed through a median sternotomy using cardiopulmonary bypass. At a median follow-up of 6.1 years (range, 9 days to 17 years), only 2 patients required surgical or catheter-based intervention for RAAO. Hypertension was present in 10% of patients at last follow-up. There were no neurologic or renal complications. There was 1 perioperative death after an aortic arch advancement in group 1. Four other patients have died during follow-up, none of the deaths related to RAAO. Anatomic repair of RAAO is a safe procedure associated with low morbidity and mortality, and low long-term reintervention rates. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Modelling of Spring Constant and Pull-down Voltage of Non-uniform RF MEMS Cantilever Incorporating Stress Gradient

    Directory of Open Access Journals (Sweden)

    Shimul Chandra SAHA

    2008-11-01

    Full Text Available We have presented a model for spring constant and pull-down voltage of a non-uniform radio frequency microelectromechanical systems (RF MEMS cantilever that works on electrostatic actuation. The residual stress gradient in the beam material that may arise during the fabrication process is also considered in the model. Using basic force deflection calculation of the suspended beam, a stand-alone model for the spring constant and pull-down voltage of the non-uniform cantilever is developed. To compare the model, simulation is performed using standard Finite Element Method (FEM analysis tolls from CoventorWare. The model matches very well with the FEM simulation results. The model will offer an efficient means of design, analysis, and optimization of RF MEMS cantilever switches.

  15. Determination of Young's modulus of epoxy coated polyethylene micro-cantilever using phase-shift shadow moiré method

    Science.gov (United States)

    Lim, J. H.; Ratnam, M. M.; Azid, I. A.; Mutharasu, D.

    2011-11-01

    Young's moduli of various epoxy coated polyethylene terephthalate (PET) micro-cantilevers were determined from the deflection results obtained using the phase-shift shadow moiré (PSSM) method. The filler materials for epoxy coatings were aluminum and graphite powders that were mixed with epoxy at various percentages. Young's moduli were calculated from theory based on the deflection results. The PET micro-cantilever coated with aluminum-epoxy coating showed increasing value of Young's modulus when the ratios of the aluminum-epoxy were increased. The graphite-epoxy coating on the PET micro-cantilever also showed the same trend. The experimental results also show that Young's modulus of the graphite-epoxy coating is higher than aluminum-epoxy coating in comparison at the same mixing ratio.

  16. The Response of Clamped Shallow Sandwich Arches with Metallic Foam Cores to Projectile Impact Loading

    Directory of Open Access Journals (Sweden)

    Yanping Fan

    Full Text Available Abstract The dynamic response and energy absorption capabilities of clamped shallow sandwich arches with aluminum foam core were numerically investigated by impacting the arches at mid-span with metallic foam projectiles. The typical deformation modes, deflection response, and core compression of sandwich arches obtained from the tests were used to validate the computation model. The resistance to impact loading was quantified by the permanent transverse deflection at mid-span of the arches as a function of projectile momentum. The sandwich arches have a higher shock resistance than the monolithic arches of equal mass, and shock resistance could be significantly enhanced by optimizing geometrical configurations. Meanwhile, decreasing the face-sheet thickness and curvature radius could enhance the energy absorption capability of the sandwich arches. Finite element calculations indicated that the ratio of loading time to structural response time ranged from 0.1 to 0.4. The projectile momentum, which was solely used to quantify the structural response of sandwich arches, was insufficient. These findings could provide guidance in conducting further theoretical studies and producing the optimal design of metallic sandwich structures subjected to impact loading.

  17. Adhesives for fixed orthodontic bands.

    Science.gov (United States)

    Millett, Declan T; Glenny, Anne-Marie; Mattick, Rye Cr; Hickman, Joy; Mandall, Nicky A

    2016-10-25

    Orthodontic treatment involves using fixed or removable appliances (dental braces) to correct the positions of teeth. It has been shown that the quality of treatment result obtained with fixed appliances is much better than with removable appliances. Fixed appliances are, therefore, favoured by most orthodontists for treatment. The success of a fixed orthodontic appliance depends on the metal attachments (brackets and bands) being attached securely to the teeth so that they do not become loose during treatment. Brackets are usually attached to the front and side teeth, whereas bands (metal rings that go round the teeth) are more commonly used on the back teeth (molars). A number of adhesives are available to attach bands to teeth and it is important to understand which group of adhesives bond most reliably, as well as reducing or preventing dental decay during the treatment period. To evaluate the effectiveness of the adhesives used to attach bands to teeth during fixed appliance treatment, in terms of:(1) how often the bands come off during treatment; and(2) whether they protect the banded teeth against decay during fixed appliance treatment. The following electronic databases were searched: Cochrane Oral Health's Trials Register (searched 2 June 2016), Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 5) in the Cochrane Library (searched 2 June 2016), MEDLINE Ovid (1946 to 2 June 2016) and EMBASE Ovid (1980 to 2 June 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. Randomised and controlled clinical trials (RCTs and CCTs) (including split-mouth studies) of adhesives used to attach orthodontic bands to molar teeth were selected. Patients with full arch fixed orthodontic appliance(s) who had bands attached to molars were included. All review authors

  18. Heater-Integrated Cantilevers for Nano-Samples Thermogravimetric Analysis

    OpenAIRE

    Toffoli, Valeria; Carrato, Sergio; Lee, Dongkyu; Jeon, Sangmin; Lazzarino, Marco

    2013-01-01

    The design and characteristics of a micro-system for thermogravimetric analysis (TGA) in which heater, temperature sensor and mass sensor are integrated into a single device are presented. The system consists of a suspended cantilever that incorporates a microfabricated resistor, used as both heater and thermometer. A three-dimensional finite element analysis was used to define the structure parameters. TGA sensors were fabricated by standard microlithographic techniques and tested using mill...

  19. High-speed dynamic atomic force microscopy by using a Q-controlled cantilever eigenmode as an actuator

    Energy Technology Data Exchange (ETDEWEB)

    Balantekin, M., E-mail: mujdatbalantekin@iyte.edu.tr

    2015-02-15

    We present a high-speed operating method with feedback to be used in dynamic atomic force microscope (AFM) systems. In this method we do not use an actuator that has to be employed to move the tip or the sample as in conventional AFM setups. Instead, we utilize a Q-controlled eigenmode of an AFM cantilever to perform the function of the actuator. Simulations show that even with an ordinary tapping-mode cantilever, imaging speed can be increased by about 2 orders of magnitude compared to conventional dynamic AFM imaging. - Highlights: • A high-speed imaging method is developed for dynamic-AFM systems. • An eigenmode of an AFM cantilever is utilized to perform fast actuation. • Simulations show 2 orders of magnitude increase in scan speed. • The time spent for dynamic-AFM imaging experiments will be minimized.

  20. Relation of Gothic arch apex to dentist-assisted centric relation.

    Science.gov (United States)

    Myers, M; Dziejma, R; Goldberg, J; Ross, R; Sharry, J

    1980-07-01

    These data suggest that the widely held belief that thumb pressure can position the mandible consistently more posterior than the position indicated by the Gothic arch apex is unfounded. Furthermore, this study provides no evidence to support the contention that the dentist-assisted jaw relation is more reproducible than the relation indicated by the Gothic arch apex.

  1. SEM in situ MiniCantilever Beam Bending of U-10Mo/Zr/Al Fuel Elements

    Energy Technology Data Exchange (ETDEWEB)

    Mook, William [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Baldwin, Jon K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Ricardo M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mara, Nathan A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-06-16

    In this work, the fracture behavior of Al/Zr and Zr/dU-10Mo interfaces was measured via the minicantilever bend technique. The energy dissipation rates were found to be approximately 3.7-5 mj/mm2 and 5.9 mj/mm2 for each interface, respectively. It was found that in order to test the Zr/U-10Mo interface, location of the hinge of the cantilever was a key parameter. While this test could be adapted to hot cell use through careful alignment fixturing and measurement of crack lengths with an optical microscope (as opposed to SEM, which was used here out of convenience), machining of the cantilevers via MiniMill in such a way as to locate the interfaces at the cantilever hinge, as well as proper placement of a femtosecond laser notch will continue to be key challenges in a hot cell environment.

  2. Mode Coupling and Nonlinear Resonances of MEMS Arch Resonators for Bandpass Filters

    KAUST Repository

    Hajjaj, Amal Z.

    2017-01-30

    We experimentally demonstrate an exploitation of the nonlinear softening, hardening, and veering phenomena (near crossing), where the frequencies of two vibration modes get close to each other, to realize a bandpass filter of sharp roll off from the passband to the stopband. The concept is demonstrated based on an electrothermally tuned and electrostatically driven MEMS arch resonator operated in air. The in-plane resonator is fabricated from a silicon-on-insulator wafer with a deliberate curvature to form an arch shape. A DC current is applied through the resonator to induce heat and modulate its stiffness, and hence its resonance frequencies. We show that the first resonance frequency increases up to twice of the initial value while the third resonance frequency decreases until getting very close to the first resonance frequency. This leads to the phenomenon of veering, where both modes get coupled and exchange energy. We demonstrate that by driving both modes nonlinearly and electrostatically near the veering regime, such that the first and third modes exhibit softening and hardening behavior, respectively, sharp roll off from the passband to the stopband is achievable. We show a flat, wide, and tunable bandwidth and center frequency by controlling the electrothermal actuation voltage.

  3. MEMS Tunneling Micro Thermometer Based onTip Deflection of Bimetallic Cantilever Beam

    Directory of Open Access Journals (Sweden)

    Samrand K. Nezhadian

    2007-10-01

    Full Text Available Micro-electro-mechanical (MEM technology promises to significantly reduce the size, weight and cost of a variety of sensor systems. In this article has been described a highly sensitive novel type of thermometer based on deflection of a “bimetallic” microbeam. The proposed thermometer converts the thermal changes of a cantilevered bimetallic beam of submillimeter size into an electrical signal through tunneling-current modulation. The governing thermo-mechanical equation of a bimetallic cantilever beam has been derived and solved analytically. The obtained results show that the proposed tunneling micro thermometer is very sensitive to temperature changes due to exponential increasing of tunneling current but because of small gap between metallic electrodes, measurable range of temperature changes is small.

  4. The effects of initial rise and axial loads on MEMS arches

    KAUST Repository

    Tella, Sherif Adekunle

    2017-04-07

    Arch microbeams have been utilized and proposed for many uses over the past few years due to their large tunability and bistability. However, recent experimental data have shown different mechanical behavior of arches when subjected to axial loads. This paper aims to investigate in depth the influence of the competing effects of initial rise and axial loads on the mechanical behavior of micromachined arches; mainly their static deflection and resonant frequencies. Based on analytical solutions, the static response and eigenvalue problems are analyzed for various values of initial rises and axial loads. Universal curves showing the variation of the first three resonance frequencies of the arch are generated for various values of initial rise under both tensile and compressive axial loads. This study shows that increasing the tensile or compressive axial loads for different values of initial rise may lead to either increase in the stiffness of the beam or initial decrease in the stiffness, which later increases as the axial load is increased depending on the dominant effect of the initial rise of the arch and the axial load. The obtained universal curves represent useful design tools to predict the tunability of arches under axial loads for various values of initial rises. The use of the universal curves is demonstrated with an experimental case study. Analytical formulation is developed to predict the point of minimum where the trend of the resonance frequency versus axial loads changes qualitatively due to the competing effects of axial loads and initial curvature.

  5. Numerical analysis of dynamic force spectroscopy using the torsional harmonic cantilever

    International Nuclear Information System (INIS)

    Solares, Santiago D; Hoelscher, Hendrik

    2010-01-01

    A spectral analysis method has been recently introduced by Stark et al (2002 Proc. Natl Acad. Sci. USA 99 8473-8) and implemented by Sahin et al (2007 Nat. Nanotechnol. 2 507-14) using a T-shaped cantilever design, the torsional harmonic cantilever (THC), which is capable of performing simultaneous tapping-mode atomic force microscopy imaging and force spectroscopy. Here we report on numerical simulations of the THC system using a simple dual-mass flexural-torsional model, which is applied in combination with Fourier data processing software to illustrate the spectroscopy process for quality factors corresponding to liquid, air and vacuum environments. We also illustrate the acquisition of enhanced topographical images and deformed surface contours under the application of uniform forces, and compare the results to those obtained with a previously reported linear dual-spring-mass model.

  6. Study on real working performance and overload safety factor of high arch dam

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Considering the fact that high arch dams have problems such as complicated stress,high cost,and hazards after being damaged,this paper intends to study the effects of load,material strength,and safety analysis method on dam safety and working performance of arch dams.In this article,the effects of temperature,self weight exaction way and water loading on structure response are first discussed,and a more reasonable way of considering is then put forward.By taking into consideration the mechanical property of materials and comparing the effects of different yield criteria on overloading safety of high arch dams,this paper concludes that brittle characteristics of concrete should be fully considered when conducting safety assessment for high arch dams to avoid overestimating the bearing capacity of the dams.By comparing several typical projects,this paper works out a safety assessment system of multiple safety and relevant engineering analogical analysis methods,which is closer to the actual situation,and thus is able to assess the response of high arch dam structure in a more comprehensive way,elicit the safety coefficients in different situations,and provide a new way of considering the safety assessment of high arch dams.

  7. Effective way to reconstruct arch bridges using concrete walls and transverse strands

    Science.gov (United States)

    Klusáček, Ladislav; Pěkník, Robin; Nečas, Radim

    2017-09-01

    There are more than 500 masonry arch bridges in the Czech Road system and about 2500 in the Czech Railway system. Many of them are cracked in the longitudinal (span) direction. The barrel vaults are separated by the cracks into partial masonry arches without load bearing connection in transverse direction. These constructions are about 150 years old and they are also too narrow for the current road system. This paper presents a strengthening method for masonry arch bridges using transverse post-tensioning. This method is very useful not only for strengthening in the transverse direction, but widening of masonry arches can be taken as secondary effect especially in case of road bridges. Several bridges were successfully repaired with the use of this system which seems to be effective and reliable.

  8. Cost of skid roads for arch logging in West Virginia

    Science.gov (United States)

    George R., Jr. Trimble; Carl R. Barr

    1960-01-01

    In the mountain hardwood country of the northern Appalachians, tree-length skidding with tractor and arch has proved to be economical logging. One essential part of this type of logging is that tree-length logs are winched to the skid roads: tractor and arch do not run around through the woods. Winching distance is commonly 200 to 300 feet; and occasionally an extra...

  9. A surface-micromachining-based inertial micro-switch with compliant cantilever beam as movable electrode for enduring high shock and prolonging contact time

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Qiu [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Yang, Zhuoqing, E-mail: yzhuoqing@sjtu.edu.cn [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Fu, Bo; Li, Jianhua; Wu, Hao [Huaihai Industrial Group Co., Ltd., Changzhi, Shanxi Province, 046012 (China); Zhang, Qihuan; Sun, Yunna; Ding, Guifu; Zhao, Xiaolin [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China)

    2016-11-30

    Highlights: • The designed cantilever beam attached to the proof mass can endure a larger shock acceleration (∼1000 g order of magnitude) compared to those traditional designs (∼100 g order of magnitude). • Effect of the pulse width on the threshold acceleration, the response time and the contact time is investigated. • A constraint sleeve structure is introduced to lower the off-axis sensitivity. - Abstract: A novel laterally-driven inertial micro-switch with two L-shaped elastic cantilever beams as the movable electrode, which is attached to the proof mass, is proposed in this paper. The advantage of this design is that the contact time of the inertial micro-switch can be prolonged. Meanwhile, the micro-switch can withstand a higher shock than the traditional designs whose cantilever beams are attached to the fixed electrode. The designed inertial micro-switch was simulated and optimized with ANSYS software and fabricated on a quartz substrate by surface micromachining technology. The simulated result demonstrates that the threshold acceleration (a{sub ths}) under stable switch-on state is about 288 g and the contact time is about 198 μs when the pulse width of acceleration loads is 1 ms. At the same time, it indicates that the threshold acceleration, the response time and the contact time of designed micro-switch all increase with the pulse width of acceleration loads. The simulation of impact process in non-sensitive direction shows that the introduced constraint sleeve structure in the novel inertial micro-switch can lower the off-axis sensitivity. The fabricated micro-switch prototype has been tested by a standard dropping hammer system under shock accelerations with various amplitudes and pulse widths. The experimental measurements show that the contact time is about 150 μs when the threshold acceleration is about 288 g. It also indicates that the response time and the contact time both increase with the pulse width, which is consistent with the

  10. ŁPw Steel Arch Support – Designing and Test Results

    Directory of Open Access Journals (Sweden)

    Marek Rotkegel

    2013-01-01

    Full Text Available Increasingly difficult geological-mining conditions make it necessary to seek new and effective ways of securing roadways. The new types of support must meet very high strength requirements and must have very high load-bearing capacities. These two conditions were taken into consideration when an ŁPw type steel arch support was designed. High strength of the arches was obtained through using steel of improved mechanical parameters, while high load-bearing parameters were obtained through shaping elements of the support arches. The works were conducted within the framework of the targeted research project no. 6ZR8 2008 C/07012 undertaken by Huta Łabędy SA, Institute for Ferrous Metallurgy and Central Mining Institute between 2010 and 2012.

  11. Use of the bioactive resorbable plate system for zygoma and zygomatic arch replacement and fixation with modified Crockett's method for maxillectomy: A technical note.

    Science.gov (United States)

    Sukegawa, Shintaro; Kanno, Takahiro; Shibata, Akane; Matsumoto, Kenichi; Sukegawa-Takahashi, Yuka; Sakaida, Kyousuke; Furuki, Yoshihiko

    2017-07-01

    As a surgical approach targeting the pterygopalatine fossa following maxillary cancer due to tumor invasion, Crockett's method is conventional and useful. However, if the tumor is confined to the area between the maxilla and pterygopalatine fossa, it is not necessary to include the zygomatico-orbital in the access osteotomy, and the orbital floor may be preserved. Depending on the range of tumor invasion, the current study reports a more minimally invasive, modified Crockett's surgery that may be considered, which includes resection with modified osteotomy lines and repositioning with fixation of the zygoma and zygomatic arch following maxillary cancer ablation. In addition, the majority of patients with advanced maxillary cancer may require postoperative radiotherapy or chemoradiotherapy following maxillectomy according to several guidelines. Therefore, using a low-profile bioactive resorbable plate system as a method of repositioning and fixing the resected and preserved zygoma and zygomatic arch may be more effective in this modified Crockett's method for maxillectomy.

  12. Factors affecting dental biofilm in patients wearing fixed orthodontic appliances.

    Science.gov (United States)

    Mei, Li; Chieng, Joyce; Wong, Connie; Benic, Gareth; Farella, Mauro

    2017-12-01

    The aim of this study is to investigate the amount and the distribution of biofilm in patients wearing fixed appliances and its relation with age, gender, frequency of tooth brushing, and patient motivation. The sample comprised 52 patients (15.5 ± 3.6 years old, 30 females and 22 males) wearing fixed orthodontic appliances. Dental biofilm was assessed using a modified plaque index (PI). A questionnaire was used to collect patient's information, including gender, age, treatment motivation, and frequency of tooth brushing. Gingival (PI score = 0.9 ± 0.7), mesial (0.8 ± 0.6), and distal (0.8 ± 0.5) areas accumulated more biofilm than occlusal areas (0.3 ± 0.3) (P appliances have the highest biofilm accumulation on the maxillary lateral incisors and maxillary canines, particularly in the gingival area and areas behind arch wires. Less biofilm was observed in female and adult patients and in those who were self-motivated and brushed their teeth more often.

  13. Rearfoot eversion has indirect effects on plantar fascia tension by changing the amount of arch collapse.

    Science.gov (United States)

    Lee, Sae Yong; Hertel, Jay; Lee, Sung Cheol

    2010-01-01

    Rearfoot eversion motion and arch height are believed to contribute to increased tension on the plantar fascia and arch collapse during gait but the specifics of these relationships are not clear. To examine the relationships among static arch height, rearfoot eversion, dynamic arch height, and plantar fascia tension. 28 healthy males participated. After static arch height was measured, the subjects were asked to run at 4.5m/s while frontal plane rearfoot motion, dynamic arch height, and ground reaction forces were collected. The relationships among variables were examined with bivariate correlations and path analysis. The results indicated a high correlation between dynamic arch height and static arch height (r=0.642), plantar fascia tension (r=-0.797), and maximum rearfoot eversion motion during gait (r=-0.518). The path analysis model without the direct rearfoot eversion effect explained 81.2% of the variance in plantar fascia tension, while the model with the direct rearfoot eversion effect explained 82.1% of the variance in plantar fascia tension. Including the indirect effect of maximum rearfoot eversion motion on plantar fascia tension through control of dynamic arch height is the model that best explains the interrelationships of these foot characteristics. The amount of maximum rearfoot eversion motion itself is not a good predictor of plantar fascia tension, however, together with the arch height, maximum rearfoot eversion motion is a good predictor because it has a pronounced indirect effect on plantar fascia tension. Copyright 2010. Published by Elsevier Ltd.

  14. Highly Tunable Electrothermally Actuated Arch Resonator

    KAUST Repository

    Hajjaj, Amal Z.; Ramini, Abdallah; Alcheikh, Nouha; Younis, Mohammad I.

    2016-01-01

    that after some electro-thermal voltage load, the third resonance frequency starts to become more sensitive to the axial thermal stress, while the first resonance frequency becomes less sensitive. These results can be used as guidelines to utilize arches

  15. How to Perfuse: Concepts of Cerebral Protection during Arch Replacement

    Directory of Open Access Journals (Sweden)

    Andreas Habertheuer

    2015-01-01

    Full Text Available Arch surgery remains undoubtedly among the most technically and strategically challenging endeavors in cardiovascular surgery. Surgical interventions of thoracic aneurysms involving the aortic arch require complete circulatory arrest in deep hypothermia (DHCA or elaborate cerebral perfusion strategies with varying degrees of hypothermia to achieve satisfactory protection of the brain from ischemic insults, that is, unilateral/bilateral antegrade cerebral perfusion (ACP and retrograde cerebral perfusion (RCP. Despite sophisticated and increasingly individualized surgical approaches for complex aortic pathologies, there remains a lack of consensus regarding the optimal method of cerebral protection and circulatory management during the time of arch exclusion. Many recent studies argue in favor of ACP with various degrees of hypothermic arrest during arch reconstruction and its advantages have been widely demonstrated. In fact ACP with more moderate degrees of hypothermia represents a paradigm shift in the cardiac surgery community and is widely adopted as an emergent strategy; however, many centers continue to report good results using other perfusion strategies. Amidst this important discussion we review currently available surgical strategies of cerebral protection management and compare the results of recent European multicenter and single-center data.

  16. How to Perfuse: Concepts of Cerebral Protection during Arch Replacement

    Science.gov (United States)

    Habertheuer, Andreas; Wiedemann, Dominik; Kocher, Alfred; Laufer, Guenther; Vallabhajosyula, Prashanth

    2015-01-01

    Arch surgery remains undoubtedly among the most technically and strategically challenging endeavors in cardiovascular surgery. Surgical interventions of thoracic aneurysms involving the aortic arch require complete circulatory arrest in deep hypothermia (DHCA) or elaborate cerebral perfusion strategies with varying degrees of hypothermia to achieve satisfactory protection of the brain from ischemic insults, that is, unilateral/bilateral antegrade cerebral perfusion (ACP) and retrograde cerebral perfusion (RCP). Despite sophisticated and increasingly individualized surgical approaches for complex aortic pathologies, there remains a lack of consensus regarding the optimal method of cerebral protection and circulatory management during the time of arch exclusion. Many recent studies argue in favor of ACP with various degrees of hypothermic arrest during arch reconstruction and its advantages have been widely demonstrated. In fact ACP with more moderate degrees of hypothermia represents a paradigm shift in the cardiac surgery community and is widely adopted as an emergent strategy; however, many centers continue to report good results using other perfusion strategies. Amidst this important discussion we review currently available surgical strategies of cerebral protection management and compare the results of recent European multicenter and single-center data. PMID:26713319

  17. A Micro-Preconcentrator Combined Olfactory Sensing System with a Micromechanical Cantilever Sensor for Detecting 2,4-Dinitrotoluene Gas Vapor

    Directory of Open Access Journals (Sweden)

    Myung-Sic Chae

    2015-07-01

    Full Text Available Preventing unexpected explosive attacks and tracing explosion-related molecules require the development of highly sensitive gas-vapor detection systems. For that purpose, a micromechanical cantilever-based olfactory sensing system including a sample preconcentrator was developed to detect 2,4-dinitrotoluene (2,4-DNT, which is a well-known by-product of the explosive molecule trinitrotoluene (TNT and exists in concentrations on the order of parts per billion in the atmosphere at room temperature. A peptide receptor (His-Pro-Asn-Phe-Ser-Lys-Tyr-Ile-Leu-His-Gln-Arg that has high binding affinity for 2,4-DNT was immobilized on the surface of the cantilever sensors to detect 2,4-DNT vapor for highly selective detection. A micro-preconcentrator (µPC was developed using Tenax-TA adsorbent to produce higher concentrations of 2,4-DNT molecules. The preconcentration was achieved via adsorption and thermal desorption phenomena occurring between target molecules and the adsorbent. The µPC directly integrated with a cantilever sensor and enhanced the sensitivity of the cantilever sensor as a pretreatment tool for the target vapor. The response was rapidly saturated within 5 min and sustained for more than 10 min when the concentrated vapor was introduced. By calculating preconcentration factor values, we verified that the cantilever sensor provides up to an eightfold improvement in sensing performance.

  18. Anomalous Origin of the Left Vertebral Artery from the Aortic Arch.

    Science.gov (United States)

    Einstein, Evan H; Song, Linda H; Villela, Natalia L A; Fasani-Feldberg, Gregory B; Jacobs, Jonathan L; Kim, Dolly O; Nathawat, Akshay; Patel, Devika; Bender, Roger B; Peters, Daniel F

    2016-04-01

    Anatomic anomalies of the aortic arch have implications for clinical practice if their significance is understood. Our case study involves a cadaveric finding of the left vertebral artery originating directly from the aortic arch. Although this anatomical variation has been documented, the prevalence of this anomaly may be generally underestimated. After noting this anomaly, we analyzed 27 cases and found that four female cadavers had the left vertebral artery originating from the aortic arch rather than the left subclavian artery. With a prevalence rate of 14.8%, it would seem that this anomaly is more significant than previously thought, which could have implications for surgical practice.

  19. Fabrication of biopolymer cantilevers using nanoimprint lithography

    DEFF Research Database (Denmark)

    Keller, Stephan Sylvest; Feidenhans'l, Nikolaj Agentoft; Fisker-Bødker, Nis

    2011-01-01

    The biodegradable polymer poly(l-lactide) (PLLA) was introduced for the fabrication of micromechanical devices. For this purpose, thin biopolymer films with thickness around 10 μm were spin-coated on silicon substrates. Patterning of microcantilevers is achieved by nanoimprint lithography. A major...... challenge was the high adhesion between PLLA and silicon stamp. Optimized stamp fabrication and the deposition of a 125 nm thick fluorocarbon anti-stiction coating on the PLLA allowed the fabrication of biopolymer cantilevers. Resonance frequency measurements were used to estimate the Young’s modulus...

  20. A new method of stabilizing zygomatic complex and arch fractures. a ...

    African Journals Online (AJOL)

    Background: Antral packing cannot support fractures of the zygomatic arch properly because of the position, therefore the aim of this report was to document a new method by which both the zygomatic bone and arch can be stabilized. Method and Materials: Iodine soaked gauze was placed in the subzygomatic space ...

  1. Relationship between the mobility of medial longitudinal arch and postural control

    Directory of Open Access Journals (Sweden)

    Tansu Birinci

    2017-05-01

    Conclusion: Our results suggest that decrease of arch mobility on the dominant foot is associated with posterior sway by causing knee or hip strategy and preventing ankle strategy even in small perturbations. The rate of deviation from the equilibrium point and the degree of total swaying increase when arch mobility decreases.

  2. Variations of the aortic arch - a study on the most common branching patterns

    International Nuclear Information System (INIS)

    Muller, Marguerite; Schmitz, Bernd L; Schick, Melanie; Schloetzer, Wiebke; Pauls, Sandra; Roehrer, Stefan; Kapapa, Thomas

    2011-01-01

    Background: Anatomical variants of the aortic arch and its branching patterns often appear as an incidental finding during routine computed tomography (CT) scanning. These variations can be of relevance when performing angiography or endovascular interventions and may cause symptoms such as dysphagia. Purpose: To analyze common anatomical variations found within the arteries originating from the aortic arch in patients using contrast CT imaging techniques. Material and Methods: A total of 2033 contrast CT scans were analyzed. To obtain a truly representative sample, cases were chosen from different hospital departments without previous knowledge of the patient history. Results: The total percentage of variations within the analyzed patients was 13.3%. In 8.0% a truncus bicaroticus was found. 4.2% of the patients showed a left vertebral artery originating directly from the aortic arch, mostly proximal, and in 1 case distal to the left subclavian artery. In 1.0% we found an aberrant right subclavian artery. We also found a single case of a right descending aortic arch. Conclusion: Variations of the aortic arch and its branching are frequently found, mostly as an incidental finding during routine diagnostic scanning. A contrast-enhanced CT scan is a good method with which to study the aortic arch and its associated branching pattern

  3. Variations of the aortic arch - a study on the most common branching patterns

    Energy Technology Data Exchange (ETDEWEB)

    Muller, Marguerite; Schmitz, Bernd L; Schick, Melanie; Schloetzer, Wiebke (Dept. of Diagnostic and Interventional Radiology, Section Neuroradiology, Univ. Ulm (Germany)), email: marguerite.mueller@uni-ulm.de; Pauls, Sandra (Dept. of Diagnostic and Interventional Radiology, Univ. Ulm (Germany)); Roehrer, Stefan; Kapapa, Thomas (Dept. of Neurosurgery, Univ. Ulm (Germany))

    2011-09-15

    Background: Anatomical variants of the aortic arch and its branching patterns often appear as an incidental finding during routine computed tomography (CT) scanning. These variations can be of relevance when performing angiography or endovascular interventions and may cause symptoms such as dysphagia. Purpose: To analyze common anatomical variations found within the arteries originating from the aortic arch in patients using contrast CT imaging techniques. Material and Methods: A total of 2033 contrast CT scans were analyzed. To obtain a truly representative sample, cases were chosen from different hospital departments without previous knowledge of the patient history. Results: The total percentage of variations within the analyzed patients was 13.3%. In 8.0% a truncus bicaroticus was found. 4.2% of the patients showed a left vertebral artery originating directly from the aortic arch, mostly proximal, and in 1 case distal to the left subclavian artery. In 1.0% we found an aberrant right subclavian artery. We also found a single case of a right descending aortic arch. Conclusion: Variations of the aortic arch and its branching are frequently found, mostly as an incidental finding during routine diagnostic scanning. A contrast-enhanced CT scan is a good method with which to study the aortic arch and its associated branching pattern

  4. Out-of-plane buckling of roller bent wide flange arches - imperfections and finite element modeling

    NARCIS (Netherlands)

    Spoorenberg, R.C.; Snijder, H.H.; Hoenderkamp, J.C.D.; Beg, D.; Chan, S.L.; Shu, G.P.

    2012-01-01

    Steel arches are used more and more in contemporary architecture, combining structural efficiency with architectural merits. If lateral supports are absent, these arches are prone to out-of-plane buckling. Arches are often made by cold bending wide flange beams at ambient temperature. This

  5. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  6. Atomic force microscope cantilever as an encoding sensor for real-time displacement measurement

    International Nuclear Information System (INIS)

    Chen, Xiaomei; Koenders, Ludger; Wolff, Helmut; Haertig, Frank; Schilling, Meinhard

    2010-01-01

    A tuning fork-based atomic force microscope cantilever has been investigated for application as an encoding sensor for real-time displacement measurement. The algorithm used to encode the displacement is based on the direct count of the integer pitches of a known grating, and the calculation of the fractional parts of a pitch at the beginning and during displacement. A cross-correlation technique has been adopted and applied to the real-time signal filtering process for the determination of the pitch during scanning by using a half sinusoidal waveform template. For the first investigation, a 1D sinusoidal grating with the pitch of 300 nm is used. The repeatability of displacement measurements over a distance of 70 µm is better than 2.2 nm. As the first application, the real-time displacement of a scanning stage is measured by the new encoding principle as it is moved in an open-loop mode and closed-loop mode based on its built-in capacitance sensor

  7. All-thin-film PZT/FeGa Multiferroic Cantilevers and Their Applications in Switching Devices and Parametric Amplification

    Science.gov (United States)

    Wang, Yi; Onuta, Tiberiu-Dan; Long, Chris; Lofland, Samuel; Takeuchi, Ichiro

    2014-03-01

    We are investigating the characteristics of microfabricated PZT/FeGa multiferroic cantilevers. The cantilevers can be driven by AC or DC magnetic and electric field, and the device response can be read off as a piezo-induced voltage. We can use the multiple input parameters to operate the devices in a variety of manners for different applications. They include electromagnetic energy harvesting, pulse triggered nonlinear memory devices, and parametrically amplified ME sensors. Due to the competition of anisotropy and Zeeman energies, the mechanical resonant frequency of the cantilevers was found to follow a hysteresis behavior with DC bias magnetic field applied in the cantilever easy axis. We can also control and tune the occurrence of nonlinear bifurcation in the frequency spectrum. The resulting hysteresis in the frequency spectrum can be used to make switching devices, where the input can be DC electric and magnetic fields, as well as pulses of AC fields. We have also demonstrated parametric pumping of the response from an AC magnetic field using frequency-doubled AC electric field. The enhanced equivalent ME coefficient is as high as 10 million V/(cm*Oe), when the pumping voltage is very close to a threshold voltage. The quality factor also increases from 2000 to 80000 with pumping.

  8. Nonlinear vibration of rectangular atomic force microscope cantilevers by considering the Hertzian contact theory

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, A., E-mail: a_sadeghi@srbiau.ac.ir [Islamic Azad Univ., Dept. of Mechanical and Aerospace Engineering, Science and Research Branch, Tehran (Iran, Islamic Republic of); Zohoor, H. [Sharif Univ. of Technology, Center of Excellence in Design, Robotics and Automation, Tehran (Iran, Islamic Republic of); The Academy of Sciences if I.R. Iran (Iran, Islamic Republic of)

    2010-05-15

    The nonlinear flexural vibration for a rectangular atomic force microscope cantilever is investigated by using Timoshenko beam theory. In this paper, the normal and tangential tip-sample interaction forces are found from a Hertzian contact model and the effects of the contact position, normal and lateral contact stiffness, tip height, thickness of the beam, and the angle between the cantilever and the sample surface on the nonlinear frequency to linear frequency ratio are studied. The differential quadrature method is employed to solve the nonlinear differential equations of motion. The results show that softening behavior is seen for most cases and by increasing the normal contact stiffness, the frequency ratio increases for the first mode, but for the second mode, the situation is reversed. The nonlinear-frequency to linear-frequency ratio increases by increasing the Timoshenko beam parameter, but decreases by increasing the contact position for constant amplitude for the first and second modes. For the first mode, the frequency ratio decreases by increasing both of the lateral contact stiffness and the tip height, but increases by increasing the angle α between the cantilever and sample surface. (author)

  9. Microfabricated photoplastic cantilever with integrated photoplastic/carbon based piezoresistive strain sensor

    DEFF Research Database (Denmark)

    Gammelgaard, Lauge; Rasmussen, Peter Andreas; Calleja, M.

    2006-01-01

    We present an SU-8 micrometer sized cantilever strain sensor with an integrated piezoresistor made of a conductive composite of SU-8 polymer and carbon black particles. The composite has been developed using ultrasonic mixing. Cleanroom processing of the polymer composite has been investigated...

  10. Nonlinear Phenomena in the Single-Mode Dynamics in an AFM Cantilever Beam

    KAUST Repository

    Ruzziconi, Laura; Lenci, Stefano; Younis, Mohammad I.

    2016-01-01

    This study deals with the nonlinear dynamics arising in an atomic force microscope cantilever beam. After analyzing the static behavior, a single degree of freedom Galerkin reduced order model is introduced, which describes the overall scenario

  11. C-arm guided closed reduction of zygomatic arch fracture

    International Nuclear Information System (INIS)

    Eo, Yoon Ki; Lee, Dong Kun; Kim, Jeong Sam; Jang, Young Il

    1999-01-01

    The zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Alling and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients

  12. Correlation of atherosclerotic changes in peripheral arteries with pathological involvement of aortic arch in coronary bypass patients

    Directory of Open Access Journals (Sweden)

    Eshraghi N

    2010-10-01

    Full Text Available "nBackground: A correlation between coronary artery disease (CAD and atherosclerosis of peripheral arteries and the determination of noninvasive indexes for its existence and extent have been sought by many researchers. Some studies report that the intima-media thickness (IMT of peripheral arteries could play this role. This study evaluated the correlation between the IMTs of common carotid and common femoral arteries and the degree of atherosclerosis in aortic arch and to evaluate the severity of CAD in candidates of coronary artery bypass grafting (CABG."n "nMethods: In a cross-sectional analytic-descriptive study, The severity of CAD, the grade of atherosclerosis of the aortic arch, and the IMTs of the common carotid and common femoral arteries were determined."n "nResults: There was a significant weak positive correlation between the IMT of common carotid artery (ρ = 0.193, p = 0.039 and common femoral artery (ρ = 0.206, p = 0.028 with the number of involved carotid vessels; the mean of these two parameters was not significantly different between the three CAD groups. There was not any significant relation between the IMTs of common carotid and common femoral arteries with the severity of atherosclerosis in the aortic arch too. There was not any significant relation between the presences of atherosclerotic plaque in the common carotid or the common femoral arteries with the severity of CAD. The severe atherosclerosis of the aortic arch was significantly higher in patients with three vessel disease."n "nConclusion: According to our results, the IMTs of common carotid and/or common femoral arteries may increase with the severity of CAD; however, these parameters are not a surrogate for predicting the CAD severity.

  13. Instability of a cantilevered flexible plate in viscous channel flow

    Science.gov (United States)

    Balint, T. S.; Lucey, A. D.

    2005-10-01

    The stability of a flexible cantilevered plate in viscous channel flow is studied as a representation of the dynamics of the human upper airway. The focus is on instability mechanisms of the soft palate (flexible plate) that cause airway blockage during sleep. We solve the Navier Stokes equations for flow with Reynolds numbers up to 1500 fully coupled with the dynamics of the plate motion solved using finite-differences. The study is 2-D and based upon linearized plate mechanics. When both upper and lower airways are open, the plate is found to lose its stability through a flutter mechanism and a critical Reynolds number exists. When one airway is closed, the plate principally loses its stability through a divergence mechanism and a critical flow speed exists. However, below the divergence-onset flow speed, flutter can exist for low levels of structural damping in the flexible plate. Our results serve to extend understanding of flow-induced instability of cantilevered flexible plates and will ultimately improve the diagnosis and treatment of upper-airway disorders.

  14. Fluid-structure interactions of photo-responsive polymer cantilevers

    Science.gov (United States)

    Bin, Jonghoon; Oates, William S.; Yousuff Hussaini, M.

    2013-02-01

    A new class of photomechanical liquid crystal networks (LCNs) has emerged, which generate large bending deformation and fast response times that scale with the resonance of the polymer films. Here, a numerical study is presented that describes the photomechanical structural dynamic behavior of an LCN in a fluid medium; however, the methodology is also applicable to fluid-structure interactions of a broader range of adaptive structures. Here, we simulate the oscillation of photomechanical cantilevers excited by light while simultaneously modeling the effect of the surrounding fluid at different ambient pressures. The photoactuated LCN is modeled as an elastic thin cantilever plate, and gradients in photostrain from the external light are computed from the assumptions of light absorption and photoisomerization through the film thickness. Numerical approximations of the equations governing the plate are based on cubic B-spline shape functions and a second order implicit Newmark central scheme for time integration. For the fluid, three dimensional unsteady incompressible Navier-Stokes equations are solved using the arbitrary Lagrangian-Eulerian (ALE) method, which employs a structured body-fitted curvilinear coordinate system where the solid-fluid interface is a mesh line of the system, and the complicated interface boundary conditions are accommodated in a conventional finite-volume formulation. Numerical examples are given which provide new insight into material behavior in a fluid medium as a function of ambient pressure.

  15. Temperature effects in Au piezoresistors integrated in SU-8 cantilever chips

    DEFF Research Database (Denmark)

    Johansson, Alicia; Hansen, Ole; Hales, Jan Harry

    2006-01-01

    We present a cantilever-based biosensor chip made for the detection of biochemical molecules. The device is fabricated entirely in the photosensitive polymer SU-8 except for integrated piezoresistors made of Au. The integrated piezoresistors are used to monitor the surface stress changes due to b...

  16. Nonlinear behaviour of cantilevered carbon nanotube resonators based on a new nonlinear electrostatic load model

    Science.gov (United States)

    Farokhi, Hamed; Païdoussis, Michael P.; Misra, Arun K.

    2018-04-01

    The present study examines the nonlinear behaviour of a cantilevered carbon nanotube (CNT) resonator and its mass detection sensitivity, employing a new nonlinear electrostatic load model. More specifically, a 3D finite element model is developed in order to obtain the electrostatic load distribution on cantilevered CNT resonators. A new nonlinear electrostatic load model is then proposed accounting for the end effects due to finite length. Additionally, a new nonlinear size-dependent continuum model is developed for the cantilevered CNT resonator, employing the modified couple stress theory (to account for size-effects) together with the Kelvin-Voigt model (to account for nonlinear damping); the size-dependent model takes into account all sources of nonlinearity, i.e. geometrical and inertial nonlinearities as well as nonlinearities associated with damping, small-scale, and electrostatic load. The nonlinear equation of motion of the cantilevered CNT resonator is obtained based on the new models developed for the CNT resonator and the electrostatic load. The Galerkin method is then applied to the nonlinear equation of motion, resulting in a set of nonlinear ordinary differential equations, consisting of geometrical, inertial, electrical, damping, and size-dependent nonlinear terms. This high-dimensional nonlinear discretized model is solved numerically utilizing the pseudo-arclength continuation technique. The nonlinear static and dynamic responses of the system are examined for various cases, investigating the effect of DC and AC voltages, length-scale parameter, nonlinear damping, and electrostatic load. Moreover, the mass detection sensitivity of the system is examined for possible application of the CNT resonator as a nanosensor.

  17. First and second branchial arch syndromes: multimodality approach

    Energy Technology Data Exchange (ETDEWEB)

    Senggen, Elodie; Laswed, Tarek; Meuwly, Jean-Yves; Maestre, Leonor Alamo; Meuli, Reto; Gudinchet, Francois [University Hospital of Lausanne, Radiology Department, Lausanne (Switzerland); Jaques, Bertrand [University Hospital of Lausanne, Department of Otorhinolaryngology, Lausanne (Switzerland)

    2011-05-15

    First and second branchial arch syndromes (BAS) manifest as combined tissue deficiencies and hypoplasias of the face, external ear, middle ear and maxillary and mandibular arches. They represent the second most common craniofacial malformation after cleft lip and palate. Extended knowledge of the embryology and anatomy of each branchial arch derivative is mandatory for the diagnosis and grading of different BAS lesions and in the follow-up of postoperative patients. In recent years, many new complex surgical approaches and procedures have been designed by maxillofacial surgeons to treat extensive maxillary, mandibular and external and internal ear deformations. The purpose of this review is to evaluate the role of different imaging modalities (orthopantomogram (OPG), lateral and posteroanterior cephalometric radiographs, CT and MRI) in the diagnosis of a wide spectrum of first and second BAS, including hemifacial microsomia, mandibulofacial dysostosis, branchio-oto-renal syndrome, Pierre Robin sequence and Nager acrofacial dysostosis. Additionally, we aim to emphasize the importance of the systematic use of a multimodality imaging approach to facilitate the precise grading of these syndromes, as well as the preoperative planning of different reconstructive surgical procedures and their follow-up during treatment. (orig.)

  18. Modal parameters identification and monitoring of two arches

    Directory of Open Access Journals (Sweden)

    Belloli Marco

    2015-01-01

    Full Text Available The paper presents the results of the modal parameters identification and of the continuous monitoring of two arches built in the new area of Expo 2015 in Milan. The activities on the arches were performed during the erection stage and they were planned as a consequence of preliminary studies performed at Politecnico di Milano wind tunnel, that highlighted dynamic instability due to the wind. In particular, the first two bending modes of the structures showed a critical behaviour and for this reason a TMD (Tuned Mass Damping system was designed in order to control these modes. At first, frequencies, damping and modal deflected shapes were evaluated in order to check the numerical FEM model, to tune the TMD system and to check its correct functioning. The two arches were then monitored for several months to observe their dynamic behaviour under different wind conditions. A good database about the strongest and the most frequent winds in the site was obtained. The accelerations registered under strong wind conditions did not reach dangerous levels for the structures, moreover these results showed a good agreement with the wind tunnel ones.

  19. First and second branchial arch syndromes: multimodality approach

    International Nuclear Information System (INIS)

    Senggen, Elodie; Laswed, Tarek; Meuwly, Jean-Yves; Maestre, Leonor Alamo; Meuli, Reto; Gudinchet, Francois; Jaques, Bertrand

    2011-01-01

    First and second branchial arch syndromes (BAS) manifest as combined tissue deficiencies and hypoplasias of the face, external ear, middle ear and maxillary and mandibular arches. They represent the second most common craniofacial malformation after cleft lip and palate. Extended knowledge of the embryology and anatomy of each branchial arch derivative is mandatory for the diagnosis and grading of different BAS lesions and in the follow-up of postoperative patients. In recent years, many new complex surgical approaches and procedures have been designed by maxillofacial surgeons to treat extensive maxillary, mandibular and external and internal ear deformations. The purpose of this review is to evaluate the role of different imaging modalities (orthopantomogram (OPG), lateral and posteroanterior cephalometric radiographs, CT and MRI) in the diagnosis of a wide spectrum of first and second BAS, including hemifacial microsomia, mandibulofacial dysostosis, branchio-oto-renal syndrome, Pierre Robin sequence and Nager acrofacial dysostosis. Additionally, we aim to emphasize the importance of the systematic use of a multimodality imaging approach to facilitate the precise grading of these syndromes, as well as the preoperative planning of different reconstructive surgical procedures and their follow-up during treatment. (orig.)

  20. A Modified Transpalatal Arch with Sleeve

    Directory of Open Access Journals (Sweden)

    Ashish Gupta

    2013-01-01

    Full Text Available Conventionally fabricated transpalatal arches often create deep grooves on the tongue causing discomfort to the patients. To ovecome this situation a modification has been devised which requires only a few minutes of lab time, thus enhancing patient′s compliance toward treatment.