WorldWideScience

Sample records for cancer single-photon computed

  1. Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.

    Science.gov (United States)

    Schillaci, Orazio

    2006-10-01

    In nuclear oncology, despite the fast-growing diffusion of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET), single-photon emission computed tomography (SPECT) studies can still play an useful clinical role in several applications. The main limitation of SPECT imaging with tumor-seeking agents is the lack of the structural delineation of the pathologic processes they detect; this drawback sometimes renders SPECT interpretation difficult and can diminish its diagnostic accuracy. Fusion with morphological studies can overcome this limitation by giving an anatomical map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT images proved to be time-consuming and impractical for routine use. The recent development of dual-modality integrated imaging systems that provide functional (SPECT) and anatomical (CT) images in the same scanning session, with the acquired images coregistered by means of the hardware, has opened a new era in this field. The first reports indicate that SPECT/CT is very useful in cancer imaging because it is able to provide further information of clinical value in several cases. In SPECT, studies of lung cancer and malignant lymphomas using different radiopharmaceutical, hybrid images are of value in providing the correct localization of tumor sites, with a precise detection of the involved organs, and the definition of their functional status, and in allowing the exclusion of disease in sites of physiologic tracer uptake. Therefore, in lung cancer and lymphomas, hybrid SPECT/CT can play a role in the diagnosis of the primary tumor, in the staging of the disease, in the follow-up, in the monitoring of therapy, in the detection of recurrence, and in dosimetric estimations for target radionuclide therapy.

  2. Comparison of single photon emission computed tomography-computed tomography, computed tomography, single photon emission computed tomography and planar scintigraphy for characterization of isolated skull lesions seen on bone scintigraphy in cancer patients

    International Nuclear Information System (INIS)

    Sharma, Punit; Jain, Tarun Kumar; Reddy, Rama Mohan; Faizi, Nauroze Ashgar; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh

    2014-01-01

    The purpose of this study is to evaluate the added value of single photon emission computed tomography-computed tomography (SPECT-CT) over planar scintigraphy, SPECT and CT alone for characterization of isolated skull lesions in bone scintigraphy (BS) in cancer patients. A total of 32 cancer patients (age: 39.5 ± 21.9; male: female - 1:1) with 36 isolated skull lesions on planar BS, underwent SPECT-CT of skull. Planar BS, SPECT, CT and SPECT-CT images were evaluated in separate sessions to minimize recall bias. A scoring scale of 1-5 was used, where 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. With receiver operating characteristic analysis area under the curves (AUC) was calculated for each modality. For calculation of sensitivity, specificity and predictive values a Score ≤3 was taken as metastatic. Clinical/imaging follow-up and/or histopathology were taken as reference standard. Of 36 skull lesions 11 lesions each were on frontal, parietal and occipital bone while three lesions were in the temporal bone. Of these 36 lesions, 16 were indeterminate (Score-3) on planar and SPECT, five on CT and none on SPECT-CT. The AUC was largest for SPECT-CT followed by CT, SPECT and planar scintigraphy, respectively. Planar scintigraphy was inferior to SPECT-CT (P = 0.006) and CT (P = 0.012) but not SPECT (P = 0.975). SPECT was also inferior to SPECT-CT (P = 0.007) and CT (P = 0.015). Although no significant difference was found between SPECT-CT and CT (P = 0.469), the former was more specific (100% vs. 94%). SPECT-CT is better than planar scintigraphy and SPECT alone for correctly characterizing isolated skull lesions on BS in cancer patients. It is more specific than CT, but provides no significant advantage over CT alone for this purpose

  3. Evaluation of pancreatic cancers using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kume, Norihiko; Suga, Kazuyoshi; Nishigauchi, Kazuya; Uchisako, Hiromichi; Sugano, Ayame; Fujita, Takeshi; Nakanishi, Takashi; Hamasaki, Tatsunori; Suzuki, Takashi

    1995-01-01

    Radionuclide study has not been frequently applied to pancreatic cancers because of the absence of suitable radiopharmaceuticals for their positive depiction. We evaluated thallium-201 chloride ( 201 T1) SPECT for the investigation of pancreatic cancers. The subjects included 24 patients with pancreatic cancer, seven with benign disorders and 10 controls. Each patient fasted prior to the examination for more than 12 hr, and 201 T1 SPECT was obtained 10 min after the injection of 148-222 MBq of 201 T1. When the boundary of tumor uptake of 201 T1 was unclear because of the adjacent physiological liver activity, subtracted SPECT using 99m Tc-phytate was performed to clarify it. 201 T1 did not accumulate in the pancreas of the controls. In contrast, of the 24 pancreatic cancers, 21 demonstrated positive uptake, for a sensitivity rate of 87.5%, and the mean tumor/liver ratio was 0.76±0.16 (range, 0.58-1.28). Abnormal uptake was also noted in three of the seven benign disorders, but with a comparatively lower lesion/liver ratio (range, 0.35-0.51). 201 T1 activity per mg tissue in the resected specimens of two patients with pancreatic cancer revealed higher activity in the tumor than in normal parenchyma. 201 T1 uptake in the five conservatively treated pancreatic cancers showed alteration similar to the serum level of tumor markers. These results suggest that 201 T1 SPECT may have clinical potential for investigating pancreatic cancers as well as for the monitoring of treatment effect. (author)

  4. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  5. Distributed quantum computing with single photon sources

    International Nuclear Information System (INIS)

    Beige, A.; Kwek, L.C.

    2005-01-01

    Full text: Distributed quantum computing requires the ability to perform nonlocal gate operations between the distant nodes (stationary qubits) of a large network. To achieve this, it has been proposed to interconvert stationary qubits with flying qubits. In contrast to this, we show that distributed quantum computing only requires the ability to encode stationary qubits into flying qubits but not the conversion of flying qubits into stationary qubits. We describe a scheme for the realization of an eventually deterministic controlled phase gate by performing measurements on pairs of flying qubits. Our scheme could be implemented with a linear optics quantum computing setup including sources for the generation of single photons on demand, linear optics elements and photon detectors. In the presence of photon loss and finite detector efficiencies, the scheme could be used to build large cluster states for one way quantum computing with a high fidelity. (author)

  6. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  7. The Added Value of a Single-photon Emission Computed Tomography-Computed Tomography in Sentinel Lymph Node Mapping in Patients with Breast Cancer and Malignant Melanoma.

    Science.gov (United States)

    Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike

    2015-01-01

    Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation.

  8. The Added Value of a Single-photon Emission Computed Tomography-Computed Tomography in Sentinel Lymph Node Mapping in Patients with Breast Cancer and Malignant Melanoma

    International Nuclear Information System (INIS)

    Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike

    2015-01-01

    Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation

  9. Single photon emission computed tomography/spiral computed tomography fusion imaging for the diagnosis of bone metastasis in patients with known cancer

    International Nuclear Information System (INIS)

    Zhao, Zhen; Li, Lin; Li, Fanglan; Zhao, Lixia

    2010-01-01

    To evaluate single photon emission computed tomography (SPECT)/spiral computed tomography (CT) fusion imaging for the diagnosis of bone metastasis in patients with known cancer and to compare the diagnostic efficacy of SPECT/CT fusion imaging with that of SPECT alone and with SPECT + CT. One hundred forty-one bone lesions of 125 cancer patients (with nonspecific bone findings on bone scintigraphy) were investigated in the study. SPECT, CT, and SPECT/CT fusion images were acquired simultaneously. All images were interpreted independently by two experienced nuclear medicine physicians. In cases of discrepancy, consensus was obtained by a joint reading. The final diagnosis was based on biopsy proof and radiologic follow-up over at least 1 year. The final diagnosis revealed 63 malignant bone lesions and 78 benign lesions. The diagnostic sensitivity of SPECT, SPECT + CT, and SPECT/CT fusion imaging for malignant lesions was 82.5%, 93.7%, and 98.4%, respectively. Specificity was 66.7%, 80.8%, and 93.6%, respectively. Accuracy was 73.8%, 86.5%, and 95.7%, respectively. The specificity and accuracy of SPECT/CT fusion imaging for the diagnosis malignant bone lesions were significantly higher than those of SPECT alone and of SPECT + CT (P 2 = 9.855, P = 0.002). The numbers of equivocal lesions were 37, 18, and 5 for SPECT, SPECT + CT, and SPECT/CT fusion imaging, respectively, and 29.7% (11/37), 27.8% (5/18), and 20.0% (1/5) of lesions were confirmed to be malignant by radiologic follow-up over at least 1 year. SPECT/spiral CT is particularly valuable for the diagnosis of bone metastasis in patients with known cancer by providing precise anatomic localization and detailed morphologic characteristics. (orig.)

  10. Single photon emission computed tomography imaging using 99Tcm-methoxyisobutylisonitrile predict the multi-drug resistance and chemotherapy efficacy of lung cancer

    International Nuclear Information System (INIS)

    Zhang Yiqiu; Shi Hongcheng

    2008-01-01

    Chemotherapy is one of the main comprehensive treatments for lung cancer, especially for non-small cell lung cancer (NSCIC) Multi-drug resistance of lung cancer plays an important role in the failure of chemotherapy. Early detection of multi-drug resistance (MDR) is essential for choosing a suitable chemotherapy regimen for the patients of lung cancer. In recent years lots of literature reports that MDR of lung cancer is related to many kinds of multi-drug resistance protein (MRP) expression in lung cancer. Some lipophilic chemotherapy drugs and 99 Tc m -methoxyisobutylisonitrile( 99 Tc m -MIBI)may be the same substrate for some MRP. These MRP can transport them out of the tumor cells, then the chemotherapy is invalid or non-radioactive concentration. The retention of 99 Tc m -MIBI in tumor cells is correlated with the expression of MRP, thus the prediction of the MRP expression before chemotherapy or monitoring MRP expression changes in the process of chemotherapy by using the noninvasive 99 Tc m -MIBI single photon emission computed tomography imaging is helpful to predict the MDR and chemotherapy efficacy of lung cancer. (authors)

  11. Prediction of sentinel lymph node status using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of breast cancer.

    Science.gov (United States)

    Tomiguchi, Mai; Yamamoto-Ibusuki, Mutsuko; Yamamoto, Yutaka; Fujisue, Mamiko; Shiraishi, Shinya; Inao, Touko; Murakami, Kei-ichi; Honda, Yumi; Yamashita, Yasuyuki; Iyama, Ken-ichi; Iwase, Hirotaka

    2016-02-01

    Single-photon emission computed tomography (SPECT)/computed tomography (CT) improves the anatomical identification of sentinel lymph nodes (SNs). We aimed to evaluate the possibility of predicting the SN status using SPECT/CT. SN mapping using a SPECT/CT system was performed in 381 cases of clinically node-negative, operable invasive breast cancer. We evaluated and compared the values of SN mapping on SPECT/CT, the findings of other modalities and clinicopathological factors in predicting the SN status. Patients with SNs located in the Level I area were evaluated. Of the 355 lesions (94.8 %) assessed, six cases (1.6 %) were not detected using any imaging method. According to the final histological diagnosis, 298 lesions (78.2 %) were node negative and 83 lesions (21.7 %) were node positive. The univariate analysis showed that SN status was significantly correlated with the number of SNs detected on SPECT/CT in the Level I area (P = 0.0048), total number of SNs detected on SPECT/CT (P = 0.011), findings of planar lymphoscintigraphy (P = 0.011) and findings of a handheld gamma probe during surgery (P = 0.012). According to the multivariate analysis, the detection of multiple SNs on SPECT/CT imaging helped to predict SN metastasis. The number of SNs located in the Level I area detected using the SPECT/CT system may be a predictive factor for SN metastasis.

  12. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  13. Technetium-99m methylene diphosphonate uptake in the brachialis muscle hematoma in a patient with prostate cancer and coagulation disorder mimicking bone metastasis evaluated by single-photon emission tomography-computed tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshakh; Shinto, Ajit Sugunan, E-mail: dr.kamaleshwar@gmail.com [Department of Nuclear Medicine and PET/CT, Kovai Medical Centre and Hospital Limited, Coimbatore (India); Madhavan, Devdas [Department of Urology, Comprehensive Cancer Care Centre, Kovai Medical Centre and Hospital Limited, Coimbatore (India)

    2013-10-15

    We report a case of 79-year-old male with prostate cancer and coagulation disorder presented with left shoulder pain. He underwent bone scintigraphy to rule out metastasis, which showed intense foci of tracer activity in the left axilla. Hybrid single-photon emission tomography-computed tomography (SPECT/CT) of the shoulder region localized tracer uptake to the left brachialis muscle hematoma. (author)

  14. Technetium-99m methylene diphosphonate uptake in the brachialis muscle hematoma in a patient with prostate cancer and coagulation disorder mimicking bone metastasis evaluated by single-photon emission tomography-computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshakh; Shinto, Ajit Sugunan; Madhavan, Devdas

    2013-01-01

    We report a case of 79-year-old male with prostate cancer and coagulation disorder presented with left shoulder pain. He underwent bone scintigraphy to rule out metastasis, which showed intense foci of tracer activity in the left axilla. Hybrid single-photon emission tomography-computed tomography (SPECT/CT) of the shoulder region localized tracer uptake to the left brachialis muscle hematoma. (author)

  15. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... examined for the location of the tracer. Computer graphics can be used to create a 3-dimensional ... a Second Heart Attack | Spanish Cardiac Rehab Referral Card | Spanish Heart Attack Warning Signs: Patient sheet | Infographic | ...

  16. Single photon emission computed tomography in children with idiopathic seizures

    International Nuclear Information System (INIS)

    Hara, Masafumi; Takahashi, Mutsumasa; Kojima, Akihiro; Shimomura, Osamu; Kinoshita, Rumi; Tomiguchi, Seiji; Taku, Keiichi; Miike, Teruhisa

    1991-01-01

    Single photon emission computed tomography (SPECT) with N-isoprophyl-p [ 123 I]-iodoamphetamine (IMP), X-ray computed tomography (X-CT), and magnetic resonance imaging (MRI) were performed in 20 children with idiopathic seizures. In children with idiopathic seizures, SPECT could detect the abnormal sites at the highest rate (45%) compared with CT (10%) and MRI (12%), but the abnormal sites on SPECT correlated poorly with the foci on electroencephalograph (EEG). Idiopathic epilepsy with hypoperfusion on SPECT was refractory to treatment and was frequently associated with mental and/or developmental retardation. Perfusion defects on SPECT scans probably affect the development and maturation of the brain in children. (author)

  17. Quantification in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2005-01-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena; 2 - quantification in SPECT, problems and correction methods: Attenuation, scattering, un-stationary spatial resolution, partial volume effect, movement, tomographic reconstruction, calibration; 3 - Synthesis: actual quantification accuracy; 4 - Beyond the activity concentration measurement

  18. Computational Modeling of Photonic Crystal Microcavity Single-Photon Emitters

    Science.gov (United States)

    Saulnier, Nicole A.

    Conventional cryptography is based on algorithms that are mathematically complex and difficult to solve, such as factoring large numbers. The advent of a quantum computer would render these schemes useless. As scientists work to develop a quantum computer, cryptographers are developing new schemes for unconditionally secure cryptography. Quantum key distribution has emerged as one of the potential replacements of classical cryptography. It relics on the fact that measurement of a quantum bit changes the state of the bit and undetected eavesdropping is impossible. Single polarized photons can be used as the quantum bits, such that a quantum system would in some ways mirror the classical communication scheme. The quantum key distribution system would include components that create, transmit and detect single polarized photons. The focus of this work is on the development of an efficient single-photon source. This source is comprised of a single quantum dot inside of a photonic crystal microcavity. To better understand the physics behind the device, a computational model is developed. The model uses Finite-Difference Time-Domain methods to analyze the electromagnetic field distribution in photonic crystal microcavities. It uses an 8-band k · p perturbation theory to compute the energy band structure of the epitaxially grown quantum dots. We discuss a method that combines the results of these two calculations for determining the spontaneous emission lifetime of a quantum dot in bulk material or in a microcavity. The computational models developed in this thesis are used to identify and characterize microcavities for potential use in a single-photon source. The computational tools developed are also used to investigate novel photonic crystal microcavities that incorporate 1D distributed Bragg reflectors for vertical confinement. It is found that the spontaneous emission enhancement in the quasi-3D cavities can be significantly greater than in traditional suspended slab

  19. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  20. Single photon emission computed tomography of the liver

    International Nuclear Information System (INIS)

    Makler, P.T. Jr.

    1988-01-01

    Single photon emission computed tomography (SPECT) of the liver has been introduced in order to improve sensitivity and localization of space-occupying lesions. There have been numerous reports on the usefulness of the technique, as well as extensive analyses of its technical drawbacks. In general, SPECT provides a more accurate estimation of defect size than does conventional planar scintigraphy for cases in which one wishes to evaluate changes in lesion size due to therapy. The presence of a superimposed parenchymal disease, however, remains a major problem, which will only be resolved by a scanning technique that specifically detects the disease process of concern (hot spot imaging) rather than displacement of normal tissue (cold spot imaging)

  1. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  2. Single photon emission computed tomography and oth selected computer topics

    International Nuclear Information System (INIS)

    Frey, G.D.

    1981-01-01

    This book, the proceedings of a meeting in January 1980, contains 21 papers. Thirteen are devoted to aspects of emission tomography, four to nuclear cardiology, and five to other topics. The initial set of papers consists of reviews of the single photon emission tomography process. These include transverse axial tomography using scintillation cameras and other devices, longitudinal section tomography, and pin-hole and slant-hole systems. These reviews are generally well done, but as might be expected, lack any coherence from paper to paper. The papers on nuclear cardiology include several of Fourier analysis in nuclear cardiology and one on shunt quantification. Other clinical papers are on quantifying Tc-99m glucoheptonate uptake in the brain and on iron-59 retention studies. A general criticism of the book is the poor quality of photographic reproductions

  3. Diagnostic performance of combined single photon emission computed tomographic scintimammography and ultrasonography based on computer-aided diagnosis for breast cancer

    International Nuclear Information System (INIS)

    Hwang, Kyung Hoon; Choi, Duck Joo; Choe, Won Sick; Lee, Jun Gu; Kim, Jong Hyo; Lee, Hyung Ji; Om, Kyong Sik; Lee, Byeong Il

    2007-01-01

    We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors.) The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve=0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve=0.860), but there was no statistical difference in sensitivity, specificity and accuracy between the combined method and a single modality. It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer

  4. Single photon emission computed tomography in lumbar degenerative spondylolisthesis

    International Nuclear Information System (INIS)

    Ito, S.; Muro, T.; Eisenstein, S.

    1998-01-01

    Analysis of single photon emission computed tomographic images and plain X-ray films of the lumbar vertebrae was performed in 15 patients with lumbar spondylosis and 15 patients with lumbar degenerative spondylolisthesis. The facet joint and osteophyte images were observed in particular, and the slipping ratio of spondylolisthetic vertebrae was determined. The slipping ratio of degenerative spondylolisthesis ranged from 11.8 % to 22.3 %. Hot uptake of 99mTc-HMDP by both L4-5 facet joints was significantly greater in the patients with degenerative spondylolisthesis than in those with lumbar spondylosis. The hot uptake by the osteophytes in lumbar spondylosis was nearly uniform among the three inferior segments, L3-4, L4-5 and L5-S, but was localized to the spondylolisthetic vertebrae, L4-5, or L5-S, in the patients with spondylolisthesis. Half of the osteophytes with hot uptake were assigned to the 3rd degree of Nathan's grading. It was suggested that stress was localized to the slipping vertebrae and their facet joints in patients with lumbar degenerative spondylolisthesis. (author)

  5. Brain single photon emission computed tomography in neonates

    International Nuclear Information System (INIS)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.

    1989-01-01

    This study was designed to rate the clinical value of [ 123 I]iodoamphetamine (IMP) or [ 99m Tc] hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that [ 123 I]IMP or [ 99m Tc]HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit

  6. Proceedings of clinical SPECT [single photon emission computed tomography] symposium

    International Nuclear Information System (INIS)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base

  7. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    Gulati, Sheffali; Kalra, Veena; Bal, C.S.

    2000-01-01

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  8. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  9. Orthopedic applications of single photon emission computed Tomographic bone scanning

    International Nuclear Information System (INIS)

    Collier, B.D.

    1987-01-01

    When compared with planar bone scanning, single photon emission computed tomography (SPECT) has technical advantages of potential diagnostic significance. Planar imaging often superimposes substantial underlying or overlying activity on the bony structure of medical interest. SPECT, however, can be used to remove such unwanted activity. For example, in the hip the acetabulum extends downwards behind the femoral head. Therefore when using planar bone scanning techniques, the photon-deficient defect typical of avascular necrosis (AVN) of the femoral had may be obscured by activity originating in the underlying acetabulum. By using SPECT, underlying and overlying distributions of activity can be separated into sequential tomographic planes. For this reason SPECT facilitates the detection of AVN of the femoral head. When referring a patient without a history of malignancy for bone scanning, the orthopaedic surgeon usually has a specific clinical question involving a limited portion of the skeleton. Orthopaedic surgeons at their institution commonly use bone scanning to clarify the cause of back, hip or knee pain; to determine with a physiological test the significance of radiographic findings; and to establish the extent of disease at symptomatic skeletal sites such as the three compartments of the knee. In instances such as these, when clinical concern is limited to a specific anatomical region, a bone scan procedure that includes SPECT imaging of only a portion of the skeleton is appropriate. To date, SPECT of the skeletal system has most frequently been used to evaluate patients with pain the larger joints and bony structures such as the lumbar spine, hips, knees, or temporomandibular joints (TMJ)

  10. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: A retrospective study.

    Science.gov (United States)

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Kozuki, Akihito; Hata, Yasuhiro; Noda, Yoshihiro; Kouno, Michihiko; Miyagawa, Kazuyuki; Tokorodani, Ryotaro; Saisaka, Yuichi; Tokumaru, Teppei; Nakamura, Toshio; Morita, Sojiro

    2016-07-01

    The objective of this study was to determine the utility of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging for posthepatectomy remnant liver function assessment in hilar bile duct cancer patients. Thirty hilar bile duct cancer patients who underwent major hepatectomy with extrahepatic bile duct resection were retrospectively analyzed. Indocyanine green plasma clearance rate (KICG) value and estimated KICG by (99m)Tc-GSA scintigraphy (KGSA) and volumetric and functional rates of future remnant liver by (99m)Tc-GSA SPECT/CT fusion imaging were used to evaluate preoperative whole liver function and posthepatectomy remnant liver function, respectively. Remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) were used to predict future remnant liver function; major hepatectomy was considered unsafe for values liver were significantly higher than volumetric rates (median: 0.54 vs 0.46; P liver failure and mortality did not occur in the patients for whom hepatectomy was considered unsafe based on remKICG. remKGSA showed a stronger correlation with postoperative prothrombin time activity than remKICG. (99m)Tc-GSA SPECT/CT fusion imaging enables accurate assessment of future remnant liver function and suitability for hepatectomy in hilar bile duct cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  12. Single photon emission computed tomography study of human pulmonary perfusion: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Carratu, L; Sofia, M [Naples Univ. (Italy). Facolta di Medicina e Chirurgia; Salvatore, M; Muto, P; Ariemma, G [Istituto Nazionale per la Prevenzione, Lo Studio e La Cura dei Tumori Fondazione Pascale, Naples (Italy); Lopez-Majano, V [Cook County Hospital, Chicago, IL (USA). Nuclear Medicine Div.

    1984-02-01

    Single photon emission computed tomography (SPECT) was performed with /sup 99/Tcsup(m)-albumin macroaggregates to study human pulmonary perfusion in healthy subjects and patients with respiratory diseases such as chronic obstructive pulmonary disease (COPD) and lung neoplasms. The reconstructed SPECT data was displayed in coronal, transverse, sagittal plane sections and compared to conventional perfusion scans. The SPECT data gave more complicated anatomical information about the extent of damage and morphology of the pulmonary vascular bed. In healthy subjects and COPD patients, qualitative and quantitative assessment of pulmonary perfusion could be obtained from serial SPECT scans with respect to distribution and relative concentration of the injected radiopharmaceutical. Furthermore, SPECT of pulmonary perfusion has been useful in detecting the extent of damage to the pulmonary circulation. This is useful for the preoperative evaluation and staging of lung cancer.

  13. Reconfigurable Computing As an Enabling Technology for Single-Photon-Counting Laser Altimetry

    Science.gov (United States)

    Powell, Wesley; Hicks, Edward; Pinchinat, Maxime; Dabney, Philip; McGarry, Jan; Murray, Paul

    2003-01-01

    Single-photon-counting laser altimetry is a new measurement technique offering significant advantages in vertical resolution, reducing instrument size, mass, and power, and reducing laser complexity as compared to analog or threshold detection laser altimetry techniques. However, these improvements come at the cost of a dramatically increased requirement for onboard real-time data processing. Reconfigurable computing has been shown to offer considerable performance advantages in performing this processing. These advantages have been demonstrated on the Multi-KiloHertz Micro-Laser Altimeter (MMLA), an aircraft based single-photon-counting laser altimeter developed by NASA Goddard Space Flight Center with several potential spaceflight applications. This paper describes how reconfigurable computing technology was employed to perform MMLA data processing in real-time under realistic operating constraints, along with the results observed. This paper also expands on these prior results to identify concepts for using reconfigurable computing to enable spaceflight single-photon-counting laser altimeter instruments.

  14. Single photon emission computed tomography by using fan beam collimator

    International Nuclear Information System (INIS)

    Akiyama, Yoshihisa

    1992-01-01

    A multislice fan beam collimator which has parallel collimation along the cephalic-caudul axis of a patient and converging collimation within planes that are perpendicular to that axis was designed for a SPECT system with a rotating scintillation camera, and it was constructed by the lead casting method which was developed in recent years. A reconstruction algorithm for fan beam SPECT was formed originally by combining the reconstruction algorithm of the parallel beam SPECT with that of the fan beam X-ray CT. The algorithm for fan beam SPECT was confirmed by means of computer simulation and a head phantom filled with diluted radionuclide. Not only 99m Tc but also 123 I was used as a radionuclide. A SPECT image with the fan beam collimator was compared with that of a parallel hole, low energy, high resolution collimator which was routinely used for clinical and research SPECT studies. Both system resolution and sensitivity of the fan beam collimator were ∼20% better than those of the parallel hole collimator. Comparing SPECT images obtained from fan beam collimator with those of parallel hole collimator, the SPECT images using fan beam collimator had far better resolution. A fan beam collimator is a useful implement for the SPECT study. (author)

  15. PET and Single-Photon Emission Computed Tomography in Brain Concussion.

    Science.gov (United States)

    Raji, Cyrus A; Henderson, Theodore A

    2018-02-01

    This article offers an overview of the application of PET and single photon emission computed tomography brain imaging to concussion, a type of mild traumatic brain injury and traumatic brain injury, in general. The article reviews the application of these neuronuclear imaging modalities in cross-sectional and longitudinal studies. Additionally, this article frames the current literature with an overview of the basic physics and radiation exposure risks of each modality. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Degenerative dementia: nosological aspects and results of single photon emission computed tomography

    International Nuclear Information System (INIS)

    Dubois, B.; Habert, M.O.

    1999-01-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  17. Imaging by single photon emission computed tomography: interest in the pre surgical check up of epilepsy

    International Nuclear Information System (INIS)

    Biraben, A.; Bernard, A.M.

    1999-01-01

    With the single photon emission computed tomography, it is a more reliable technique that is at someone's disposal, especially to limit spatially the evolution of epilepsy crisis before any surgery act. The determination of the precise area is necessary to make sure that the crisis come really from this area and the determination of the functionality of this area is checked to be sure that the ablation of the zone will not lead to an unacceptable functional deficit. (N.C.)

  18. Universal quantum computation with the orbital angular momentum of a single photon

    International Nuclear Information System (INIS)

    García-Escartín, Juan Carlos; Chamorro-Posada, Pedro

    2011-01-01

    We prove that a single photon with quantum data encoded in its orbital angular momentum can be manipulated with simple optical elements to provide any desired quantum computation. We will show how to build any quantum unitary operator using beamsplitters, phase shifters, holograms and an extraction gate based on quantum interrogation. The advantages and challenges of these approach are then discussed, in particular the problem of the readout of the results

  19. Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas.

    Science.gov (United States)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Bhadada, Sanjay

    2011-01-01

    Primary hyperparathyroidism results from excessive parathyroid hormone secretion. Approximately 85% of all cases of primary hyperparathyroidism are caused by a single parathyroid adenoma; 10-15% of the cases are caused by parathyroid hyperplasia. Parathyroid carcinoma accounts for approximately 3-4% of cases of primary disease. Technetium-99m-sestamibi (MIBI), the current scintigraphic procedure of choice for preoperative parathyroid localization, can be performed in various ways. The "single-isotope, double-phase technique" is based on the fact that MIBI washes out more rapidly from the thyroid than from abnormal parathyroid tissue. However, not all parathyroid lesions retain MIBI and not all thyroid tissue washes out quickly, and subtraction imaging is helpful. Single photon emission computed tomography (SPECT) provides information for localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, and detecting and localizing ectopic parathyroid lesions. Addition of CT with SPECT improves the sensitivity. This pictorial assay demonstrates various SPECT/CT patterns observed in parathyroid scintigraphy.

  20. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  1. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  2. Left ventricular volume determination from single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-01-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting

  3. Left ventricular volume determination from single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-02-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.

  4. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT

  5. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  6. Bronchobiliary Fistula Localized by Cholescintigraphy with Single-Photon Emission Computed Tomography

    International Nuclear Information System (INIS)

    Artunduaga, Maddy; Patel, Niraj R.; Wendt, Julie A.; Guy, Elizabeth S.; Nachiappan, Arun C.

    2015-01-01

    Biliptysis is an important clinical feature to recognize as it is associated with bronchobiliary fistula, a rare entity. Bronchobiliary fistulas have been diagnosed with planar cholescintigraphy. However, cholescintigraphy with single-photon emission computed tomography (SPECT) can better spatially localize a bronchobiliary fistula as compared to planar cholescintigraphy alone, and is useful for preoperative planning if surgical treatment is required. Here, we present the case of a 23-year-old male who developed a bronchobiliary fistula in the setting of posttraumatic and postsurgical infection, which was diagnosed and localized by cholescintigraphy with SPECT

  7. An analysis of regional cerebral blood flow in impulsive murderers using single photon emission computed tomography.

    Science.gov (United States)

    Amen, Daniel G; Hanks, Chris; Prunella, Jill R; Green, Aisa

    2007-01-01

    The authors explored differences in regional cerebral blood flow in 11 impulsive murderers and 11 healthy comparison subjects using single photon emission computed tomography. The authors assessed subjects at rest and during a computerized go/no-go concentration task. Using statistical parametric mapping software, the authors performed voxel-by-voxel t tests to assess significant differences, making family-wide error corrections for multiple comparisons. Murderers were found to have significantly lower relative rCBF during concentration, particularly in areas associated with concentration and impulse control. These results indicate that nonemotionally laden stimuli may result in frontotemporal dysregulation in people predisposed to impulsive violence.

  8. Brain receptor single-photon emission computer tomography with 123I Datscan in Parkinson's disease

    International Nuclear Information System (INIS)

    Minchev, D.; Peshev, N.; Kostadinova, I.; Grigorova, O.; Trindev, P.; Shotekov, P.

    2005-01-01

    Clinical aspects of Parkinson's disease are not enough for the early diagnosis of the disease. Positron emission tomography and the receptor single - photon emission tomography can be used for imaging functional integrity of nigrostriatal dopaminergic structures. 24 patient (17 men and 7 women) were investigated. 20 of them are with Parkinson's disease and 4 are with essential tremor. The radiopharmaceutical - 123I-Datscan (ioflupane, bind with 123I) represent a cocaine analogue with selective affinity to dopamine transporters, located in the dopaminergic nigrostriatal terminals in the striatum. Single - photon emission computer tomography was performed with SPECT gamma camera (ADAC, SH Epic detector). The scintigraphic study was made 3 to 6 hours after intravenous injection of the radiopharmaceutical - 123I- Datscan in dose 185 MBq. 120 frames are registered with duration of each one 22 seconds and gamma camera rotation 360. After generation of transversal slices we generated two composites pictures. The first composite picture image the striatum, the second - the occipital region. Two ratios were calculated representing the uptake of the radiopharmaceutical in the left and right striatum. Qualitative and quantitative criteria were elaborated for evaluating the scintigraphic patterns. Decreased, nonhomogeneous and asymmetric uptake of the radiopharmaceutical coupled with low quantitative parameters in range from 1.44 to 2.87 represents the characteristic scintigraphic pattern for Parkinson's disease with clear clinical picture. Homogenous with high intensity and symmetric uptake of the radiopharmaceutical in the striatum coupled with his clear frontier and with quantitative parameters up to 4.40 represent the scintigraphic pattern in two patients with essential tremor. Receptor single - photon emission computer tomography with 123I - Datscan represents an accurate nuclear-medicine method for precise diagnosis of Parkinson's disease and for its differentiation from

  9. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  10. DE-BLURRING SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGES USING WAVELET DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    Neethu M. Sasi

    2016-02-01

    Full Text Available Single photon emission computed tomography imaging is a popular nuclear medicine imaging technique which generates images by detecting radiations emitted by radioactive isotopes injected in the human body. Scattering of these emitted radiations introduces blur in this type of images. This paper proposes an image processing technique to enhance cardiac single photon emission computed tomography images by reducing the blur in the image. The algorithm works in two main stages. In the first stage a maximum likelihood estimate of the point spread function and the true image is obtained. In the second stage Lucy Richardson algorithm is applied on the selected wavelet coefficients of the true image estimate. The significant contribution of this paper is that processing of images is done in the wavelet domain. Pre-filtering is also done as a sub stage to avoid unwanted ringing effects. Real cardiac images are used for the quantitative and qualitative evaluations of the algorithm. Blur metric, peak signal to noise ratio and Tenengrad criterion are used as quantitative measures. Comparison against other existing de-blurring algorithms is also done. The simulation results indicate that the proposed method effectively reduces blur present in the image.

  11. A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Murase, Kenya; Itoh, Hisao; Mogami, Hiroshi; Ishine, Masashiro; Kawamura, Masashi; Iio, Atsushi; Hamamoto, Ken

    1987-01-01

    A computer based simulation method was developed to assess the relative effectiveness and availability of various attenuation compensation algorithms in single photon emission computed tomography (SPECT). The effect of the nonuniformity of attenuation coefficient distribution in the body, the errors in determining a body contour and the statistical noise on reconstruction accuracy and the computation time in using the algorithms were studied. The algorithms were classified into three groups: precorrection, post correction and iterative correction methods. Furthermore, a hybrid method was devised by combining several methods. This study will be useful for understanding the characteristics limitations and strengths of the algorithms and searching for a practical correction method for photon attenuation in SPECT. (orig.)

  12. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  13. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia

    International Nuclear Information System (INIS)

    Boudousq, V.; Collombier, L.; Kotzki, P.O.

    1999-01-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  14. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  15. Single-photon emission computed tomography in human immunodeficiency virus encephalopathy: A preliminary report

    International Nuclear Information System (INIS)

    Masdeu, J.C.; Yudd, A.; Van Heertum, R.L.; Grundman, M.; Hriso, E.; O'Connell, R.A.; Luck, D.; Camli, U.; King, L.N.

    1991-01-01

    Depression or psychosis in a previously asymptomatic individual infected with the human immunodeficiency virus (HIV) may be psychogenic, related to brain involvement by the HIV or both. Although prognosis and treatment differ depending on etiology, computed tomography (CT) and magnetic resonance imaging (MRI) are usually unrevealing in early HIV encephalopathy and therefore cannot differentiate it from psychogenic conditions. Thirty of 32 patients (94%) with HIV encephalopathy had single-photon emission computed tomography (SPECT) findings that differed from the findings in 15 patients with non-HIV psychoses and 6 controls. SPECT showed multifocal cortical and subcortical areas of hypoperfusion. In 4 cases, cognitive improvement after 6-8 weeks of zidovudine (AZT) therapy was reflected in amelioration of SPECT findings. CT remained unchanged. SPECT may be a useful technique for the evaluation of HIV encephalopathy

  16. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  17. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...... patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent...... of the (decay corrected) brain counts were lost during 24 hours....

  18. Differentiation of malignant glioma and metastatic brain tumor by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Yasuhiro; Kuwana, Nobumasa; Noji, Masato; Tosa, Junichi [Yokohama Minami Kyosai Hospital (Japan)

    1994-09-01

    The use of superdelayed thallium-201 single photon emission computed tomography ([sup 201]Tl SPECT) for differentiating malignant gliomas from cerebral metastases was investigated in 23 patients (7 with meningioma, 6 with glioma, 7 with cerebral metastasis, 1 with each of neurinoma, abscess, and necrosis). 4 mCi of [sup 201]Tl was injected intravenously, and gamma camera scans were performed after 10 minutes and 4, 24, 72, and 96 hours (superdelayed scan). The mean thallium index of meningiomas was significantly higher than those of gliomas and cerebral metastases after 10 minutes, while the mean thallium indices of meningiomas and gliomas were significantly higher than those of cerebral metastases after 96 hours. The combination of early and superdelayed [sup 201]Tl SPECT may be useful in differentiating malignant gliomas from cerebral metastases. (author).

  19. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2014-01-01

    Full Text Available We studied the anatomical correlates of reflex hot water epilepsy (HWE using multimodality investigations viz. magnetic resonance imaging (MRI, electroencephalography (EEG, and single photon emission computed tomography (SPECT. Five men (mean age: 27.0 ΁ 5.8 years with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  20. Single-photon emission computed tomography in the clinical evaluation of dementia

    International Nuclear Information System (INIS)

    Jagust, W.J.; Reed, B.R.; Budinger, T.F.; Colina, M.

    1987-01-01

    Physiological imaging using positron emission tomography (PET) has been a useful tool in the investigation of dementia. In particular, patterns of cerebral glucose utilization appear to differentiate various types of dementia, with Alzheimer's disease (AD) demonstrating a propensity for hypometabolism to involve the temporoparietal cortex. Single-photon emission computed tomography (SPECT) using new tracers for the measurement of regional cerebral blood flow is a technique with potentially broader clinical availability than PET and thus may provide a practical method of routinely evaluating patients. The authors studied eight patients with AD, four healthy elderly controls, and one patient with multi-infarct dementia (MID) using the tracer 123 I-N-isopropyl-p-iodoamphetamine with SPECT

  1. Brain perfusion single photon emission computed tomography in major psychiatric disorders: From basics to clinical practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Kumar, Rakesh

    2014-01-01

    Brain single photon emission computed tomography (SPECT) is a well-established and reliable method to assess brain function through measurement of regional cerebral blood flow (rCBF). It can be used to define a patient's pathophysiological status when neurological or psychiatric symptoms cannot be explained by anatomical neuroimaging findings. Though there is ample evidence validating brain SPECT as a technique to track human behavior and correlating psychiatric disorders with dysfunction of specific brain regions, only few psychiatrists have adopted brain SPECT in routine clinical practice. It can be utilized to evaluate the involvement of brain regions in a particular patient, to individualize treatment on basis of SPECT findings, to monitor the treatment response and modify treatment, if necessary. In this article, we have reviewed the available studies in this regard from existing literature and tried to present the evidence for establishing the clinical role of brain SPECT in major psychiatric illnesses

  2. Simulation Study of Single Photon Emission Computed Tomography for Industrial Applications

    International Nuclear Information System (INIS)

    Roy, Tushar; Sarkar, P. S.; Sinha, Amar

    2008-01-01

    SPECT (Single Photon Emission Computed Tomography) provides for an invaluable non-invasive technique for the characterization and activity distribution of the gamma-emitting source. For many applications of radioisotopes for medical and industrial application, not only the positional information of the distribution of radioisotopes is needed but also its strength. The well-established X-ray radiography or transmission tomography techniques do not yield sufficient quantitative information about these objects. Emission tomography is one of the important methods for such characterization. Application of parallel beam, fan beam and 3D cone beam emission tomography methods have been discussed in this paper. Simulation studies to test these algorithms have been carried out to validate the technique.

  3. Studies of left ventricular volume estimation from single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Joja, Ikuo; Aono, Kaname; Yanagi, Hidekiyo; Indo, Haruaki; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao.

    1988-01-01

    We studied the comparative accuracy of 99m Tc cardiac blood pool Single Photon Emission Computed Tomography (SPECT) for the measurement of left ventricular volume in 20 patients undergoing SPECT and single plane contrast left ventriculography (LVG). Left ventricular volume was calculated based on the total number of voxels in left ventricle. End-diastolic left ventricular volume (EDV) and end-systolic left ventricular volume (ESV) calculated from SPECT were compared with those from LVG. SPECT volume values showed a high degree of correlation with those by LVG (r = 0.923 for EDV, r = 0.903 for ESV). We appreciated the usefulness and accuracy of SPECT in measuring left ventricular volume because of its three-dimensional information. (author)

  4. Brain perfusion single photon emission computed tomography in children after acute encephalopathy

    International Nuclear Information System (INIS)

    Kurihara, Mana; Nakae, Yoichiro; Kohagizawa, Toshitaka; Eto, Yoshikatsu

    2005-01-01

    We studied single photon emission computed tomography (SPECT) of 15 children with acute encephalopathy after more than 1 year from the onset, using technetium-99 m-L, L-ethyl cystinate dimer ( 99m Tc-ECD) and a three-dementional stereotaxic region of interest template. Regional cerebral blood flow was evaluated and divided in three groups according to the severity of disability: absent or mild, moderate, and severe. There was no abnormality on SPECT in the patients without disability or with mild disability. Diffuse hypoperfusion was shown in the groups with moderate and severe disability. The patients with severe disability showed hypoperfusion in the pericallosal, frontal and central areas which was more pronounced than in the patients with moderate disability. (author)

  5. Detection of avascular necrosis in adults by single photon emission computed tomography

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnston, R.P.; Carrera, G.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.

    1984-01-01

    Twenty-one adult patients with the clinical diagnosis of avascular necrosis (AVN) of the femoral head were examined with planar bone scintigraphy (high resolution collimator) and single photon emission computed tomography (SPECT). The duration of hip pain ranged from 1 day to 18 months. Risk factors (including steroids, renal transplantation, alcoholism, and trauma) were present in 17 cases. A final diagnosis of AVN (20 hips), osteochondral facture, or stress fracture, was established for 17 patients. The 4 remaining patients, who were radiographically normal and did not complain of pain 3 months later, were thought to have no significant bone pathology. SPECT and planar bone scintigraphy were reported as positive for AVN only if a photopenic bony defect could be identified. In particular, uniformly increased activity throughout the femoral head was not considered to be diagnostic of AVN. The authors conclude that by identifying a photopenic defect which is not evident on planar bone scintigraphy, SPECT can contribute to accurate diagnosis of AVN

  6. Scintigraphic appearance of focal fatty infiltration of the liver using single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kudo, M.; Hirasa, M.; Ibuki, Y.

    1984-01-01

    Fatty infiltration of the liver had been considered to assume a uniform distribution until quite recently. However, the development of X-ray computed tomography (XCT) and the ultrasound (US) has proven that fatty infiltration of the liver may sometimes assume a nonuniform distribution (focal fatty infiltration (FFI)). This investigation was undertaken to evaluate the scintigraphic appearance of FFI using single-photon emission computed tomography (SPECT) with a GE Maxicamera 400T. Radionuclide images including SPECT were evaluated in 12 cases with FFI which were diagnosed by XCT and US. Most of them were histrogically confirmed to be positive fatty infiltration in the liver. The results were as follows. The fatty infiltrated area was visualized as a hot spot in one case, a defect in 2 cases, a low uptake in one case and a normal uptake in 8 cases. Radionuclide imaging of FFI shows a large variety of findings and it suggests that Kupffer cell function varies with the causes or stage of fatty infiltration. And one can understand the pathological state of FFI from a viewpoint of Kupffer cell function only by radionuclide imaging including SPECT, which is very useful to compare the images with XCT images

  7. The identification of spinal pathology in chronic low back pain using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Ryan, R.J.; Gibson, T.; Fogelman, I.

    1992-01-01

    Single photon emission computed tomography (SPECT) findings were investigated in 80 consecutive patients (aged 18-70 years, median 44) referred to a rheumatology outpatient clinic with low back pain persisting for more than 3 months. Lesions of the lumbar spine were demonstrated in 60% of patients using SPECT but in only 35% with planar imaging. Fifty-one per cent of all lesions were only detected by SPECT, and lesions visualized on SPECT could be precisely localized to the vertebral body, or different parts of the posterior elements. Fifty per cent of lesions involved the facetal joints of which almost 60% were identified on SPECT alone. X-rays of the lumbar spine, with posterior oblique views, failed to demonstrate abnormalities corresponding to almost all SPECT posterior element lesions although it identified abnormalities corresponding to over 60% of anterior SPECT lesions. Computed tomography (CT) was performed in 30 patients with a SPECT lesion and sites of facetal joint activity corresponded to facetal osteoarthritis in 82%. (author)

  8. Statistical noise with the weighted backprojection method for single photon emission computed tomography

    International Nuclear Information System (INIS)

    Murayama, Hideo; Tanaka, Eiichi; Toyama, Hinako.

    1985-01-01

    The weighted backprojection (WBP) method and the radial post-correction (RPC) method were compared with other several attenuation correction methods for single photon emission computed tomography by computer simulation. These methods are the pre-correction method with arithmetic means of opposing projections, the post-correction method with a correction matrix, and the inverse attenuated Randon transform method. Statistical mean square noise in a reconstructed image was formulated, and was displayed two-dimensionally for typical simulated phantoms. The noise image for the WBP method was dependent on several parameters, namely, size of an attenuating object, distribution of activity, the attenuation coefficient, and choise of the reconstruction index, k and position of the reconstruction origin. The noise image for the WBP method with k=0 was almost the same for the RPC method. It has been shown that position of the reconstruction origin has to be chosen appropriately in order to improve the noise properties of the reconstructed image for the WBP method as well as the RPC method. Comparision of the different attenuation correction methods accomplished by using both the reconstructed images and the statistical noise images with the same mathematical phantom and convolving function concluded that the WBP method and the RPC method were more amenable to any radioisotope distributions than the other methods, and had the advantage of flexibility to improve image noise of any local positions. (author)

  9. Single photon emission computed tomography using a regularizing iterative method for attenuation correction

    International Nuclear Information System (INIS)

    Soussaline, Francoise; Cao, A.; Lecoq, G.

    1981-06-01

    An analytically exact solution to the attenuated tomographic operator is proposed. Such a technique called Regularizing Iterative Method (RIM) belongs to the iterative class of procedures where a priori knowledge can be introduced on the evaluation of the size and shape of the activity domain to be reconstructed, and on the exact attenuation distribution. The relaxation factor used is so named because it leads to fast convergence and provides noise filtering for a small number of iteractions. The effectiveness of such a method was tested in the Single Photon Emission Computed Tomography (SPECT) reconstruction problem, with the goal of precise correction for attenuation before quantitative study. Its implementation involves the use of a rotating scintillation camera based SPECT detector connected to a mini computer system. Mathematical simulations of cylindical uniformly attenuated phantoms indicate that in the range of a priori calculated relaxation factor a fast converging solution can always be found with a (contrast) accuracy of the order of 0.2 to 4% given that numerical errors and noise are or not, taken into account. The sensitivity of the (RIM) algorithm to errors in the size of the reconstructed object and in the value of the attenuation coefficient μ was studied, using the same simulation data. Extreme variations of +- 15% in these parameters will lead to errors of the order of +- 20% in the quantitative results. Physical phantoms representing a variety of geometrical situations were also studied

  10. Gated single photon emission computer tomography for the detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Pena Q, Yamile; Coca P, Marco Antonio; Batista C, Juan Felipe; Fernandez-Britto, Jose; Quesada P, Rodobaldo; Pena C; Andria

    2009-01-01

    Background: Asymptomatic patients with severe coronary atherosclerosis may have a normal resting electrocardiogram and stress test. Aim: To assess the yield of Gated Single Photon Emission Computer Tomography (SPECT) for the screening of silent myocardial ischemia in type 2 diabetic patients. Material and methods: Electrocardiogram, stress test and gated-SPECT were performed on 102 type 2 diabetic patients aged 60 ± 8 years without cardiovascular symptoms. All subjects were also subjected to a coronary angiography, whose results were used as gold standard. Results: Gated-SPECT showed myocardial ischemia on 26.5% of studied patients. The sensibility, specificity, accuracy, positive predictive value and negative predictive value were 92.3%, 96%, 95%, 88.8%, 97.3%, respectively. In four and six patients ischemia was detected on resting electrocardiogram and stress test, respectively. Eighty percent of patients with doubtful resting electrocardiogram results and 70% with a doubtful stress test had a silent myocardial ischemia detected by gated-SPECT. There was a good agreement between the results of gated-SPECT and coronary angiography (k =0.873). Conclusions: Gated-SPECT was an useful tool for the screening of silent myocardial ischemia

  11. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  12. Evaluation of auto region of interest settings for single photon emission computed tomography findings

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki; Yoshioka, Katsunori

    2008-01-01

    It has been noted that the manual settings of region of interest (ROI) to the single-photon-emission-computed-tomography (SPECT) slice lacked objectivity when the fixed quantity value of regional cerebral blood flow (rCBF) was measured previously. Therefore, we jointly developed software Brain ROI' with Daiichi Radioisotope Laboratories, Ltd. (Present name: FUJIFILM RI Pharma Co., Ltd.) The software normalized an individual brain to a standard brain template by using Statistical Parametric Mapping 2 (SPM 2) of the easy Z-score Imaging System ver. 3.0 (eZIS Ver. 3.0), and the ROI template was set to a specific slice. In this study, we evaluated the accuracy of this software with an ROI template that we made of useful size and shape, in some clinical samples. The method of automatic setting of ROI was the objective. However, we felt that we should use the shape of the ROI template without the influence of brain atrophy. Moreover, we should see normalization of the individual brain and confirm the accuracy of normalization. When normalization failed, we should partially correct the ROI or set everything by manual operation for the operator. However, it was thought that this software was useful if the tendency was understood because examples of failure were few. (author)

  13. Astigmatic single photon emission computed tomography imaging with a displaced center of rotation

    International Nuclear Information System (INIS)

    Wang, H.; Smith, M.F.; Stone, C.D.; Jaszczak, R.J.

    1998-01-01

    A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that is perpendicular to this axis. Using SPECT simulations of projection data from a hot rod phantom and point source arrays, it is found that a lack of incorporation of the mechanical shift in the reconstruction algorithm causes errors and artifacts in reconstructed SPECT images. The collimator and acquisition parameters in the astigmatic reconstruction formula, which include focal lengths, radius of rotation, and mechanical shifts, are often partly unknown and can be determined using the projections of a point source at various projection angles. The accurate determination of these parameters by a least squares fitting technique using projection data from numerically simulated SPECT acquisitions is studied. These studies show that the accuracy of parameter determination is improved as the distance between the point source and the axis of rotation of the gamma camera is increased. The focal length to the focal line perpendicular to the axis of rotation is determined more accurately than the focal length to the focal line parallel to this axis. copyright 1998 American Association of Physicists in Medicine

  14. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  15. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  16. Verification of a hybrid adjoint methodology in Titan for single photon emission computed tomography - 316

    International Nuclear Information System (INIS)

    Royston, K.; Haghighat, A.; Yi, C.

    2010-01-01

    The hybrid deterministic transport code TITAN is being applied to a Single Photon Emission Computed Tomography (SPECT) simulation of a myocardial perfusion study. The TITAN code's hybrid methodology allows the use of a discrete ordinates solver in the phantom region and a characteristics method solver in the collimator region. Currently we seek to validate the adjoint methodology in TITAN for this application using a SPECT model that has been created in the MCNP5 Monte Carlo code. The TITAN methodology was examined based on the response of a single voxel detector placed in front of the heart with and without collimation. For the case without collimation, the TITAN response for single voxel-sized detector had a -9.96% difference relative to the MCNP5 response. To simulate collimation, the adjoint source was specified in directions located within the collimator acceptance angle. For a single collimator hole with a diameter matching the voxel dimension, a difference of -0.22% was observed. Comparisons to groupings of smaller collimator holes of two different sizes resulted in relative differences of 0.60% and 0.12%. The number of adjoint source directions within an acceptance angle was increased and showed no significant change in accuracy. Our results indicate that the hybrid adjoint methodology of TITAN yields accurate solutions greater than a factor of two faster than MCNP5. (authors)

  17. Brain blood flow studies with single photon emission computed tomography in patients with plateau waves

    International Nuclear Information System (INIS)

    Hayashi, Minoru; Kobayashi, Hidenori; Kawano, Hirokazu; Handa, Yuji; Noguchi, Yoshiyuki; Shirasaki, Naoki; Hirose, Satoshi

    1986-01-01

    The authors studied brain blood flow with single photon emission computed tomography (SPECT) in two patients with plateau waves. The intracranial pressure and blood pressure were also monitored continuously in these patients. They included one patient with brain-tumor (rt. sphenoid ridge meningioma) and another with hydrocephalus after subarachnoid hemorrhage due to rupture of lt. internal carotid aneurysm. The intracranial pressure was monitored through an indwelling ventricular catheter attached to a pressure transducer. The blood pressure was recorded through an intraarterial catheter placed in the dorsalis pedis artery. Brain blood flow was studied with Headtome SET-011 (manufactured by Shimazu Co., Ltd.). For this flow measurement study, an intravenous injection of Xenon-133 of about 30 mCi was given via an antecubital vein. The position of the slice for the SPECT was selected so as to obtain information not only from the cerebral hemisphere but also from the brain stem : a cross section 25 deg over the orbito-meatal line, passing through the inferior aspect of the frontal horn, the basal ganglia, the lower recessus of the third ventricle and the brain stem. The results indicated that, in the cerebral hemisphere, plateau waves were accompanied by a decrease in blood flow, whereas, in the brain stem, the blood flow showed little change during plateau waves as compared with the interval phase between two plateau waves. These observations may explain why there is no rise in the blood pressure and why patients are often alert during plateau waves. (author)

  18. Hemodynamic evaluation of vascular reconstructive surgery for childhood moyamoya disease using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Takikawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi [Hokkaido Univ., Sapporo (Japan). School of Medicine; Mitsumori, Kenji; Tsuru, Mitsuo

    1990-06-01

    To evaluate the efficacy of vascular reconstructive surgery for childhood moyamoya disease, the cerebral blood flow (CBF) in 31 hemispheres of 16 patients was examined by single photon emission computed tomography (SPECT) using the {sup 133}Xe inhalation method. Results were divided into two groups; 17 hemispheres with superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis (A(+) group) and 14 hemispheres without anastomosis (A(-) group). The mean hemispheric CBF (mCBF) and regional CBF (rCBF) in the frontal, temporal, occipital, and basal ganglia regions were calculated. Pre- and postoperative SPECT on the 10 hemispheres of the A(+) group showed an increase in mCBF in 6 hemispheres, the disappearance of the low perfusion area (LPA) in all 5 hemispheres where LPA was present before surgery, and an improvement in rCBF distribution (an increase in rCBF in the frontal and temporal lobes and a decrease in the basal ganglia). This suggests that vascular reconstruction is greatly effective in treating this disease. A comparison between the A(+) group and the A(-) group by postoperative SPECT, as well as the clinical outcomes and the postoperative findings of electroencephalography and angiography, revealed that the A(+) group was superior to the A(-) group in the frequency of LPA (12% and 43%, respectively) and rCBF in the frontal region where STA-MCA anastomosis was usually performed. These results indicate that STA-MCA anastomosis with indirect synangiosis is the most effective treatment of childhood moyamoya disease. (author).

  19. Design of a serotonin 4 receptor radiotracer with decreased lipophilicity for single photon emission computed tomography.

    Science.gov (United States)

    Fresneau, Nathalie; Dumas, Noé; Tournier, Benjamin B; Fossey, Christine; Ballandonne, Céline; Lesnard, Aurélien; Millet, Philippe; Charnay, Yves; Cailly, Thomas; Bouillon, Jean-Philippe; Fabis, Frédéric

    2015-04-13

    With the aim to develop a suitable radiotracer for the brain imaging of the serotonin 4 receptor subtype (5-HT4R) using single photon emission computed tomography (SPECT), we synthesized and evaluated a library of di- and triazaphenanthridines with lipophilicity values which were in the range expected to favour brain penetration, and which demonstrated specific binding to the target of interest. Adding additional nitrogen atoms to previously described phenanthridine ligands exhibiting a high unspecific binding, we were able to design a radioiodinated compound [(125)I]14. This compound exhibited a binding affinity value of 0.094 nM toward human 5-HT4R and a high selectivity over other serotonin receptor subtypes (5-HTR). In vivo SPECT imaging studies and competition experiments demonstrated that the decreased lipophilicity (in comparison with our previously reported compounds 4 and 5) allowed a more specific labelling of the 5-HT4R brain-containing regions. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Single photon emission computed tomography (SPECT) in seizure disorders in childhood

    International Nuclear Information System (INIS)

    Vles, J.S.H.; Demandt, E.; Ceulemans, B.; de Roo, M.; Casaer, P.J.M.

    1990-01-01

    In 38 children with partial seizures, the EEG, CT and NMR findings were compared to the results obtained with Tc99m HMPAO single photon emission computed tomography (SPECT) in order to determine whether SPECT is a useful adjunct to EEG, CT and NMR in this age group. In 3 out of 7 patients with a normal EEG, SPECT showed focal abnormalities. Nine patients whose EEGs did not show adequate lateralization had an abnormal SPECT which revealed a focus. In 14 out of 21 patients with a normal CT, SPECT showed focal changes in 13 patients and diffuse changes in the other one. In 7 out of 12 patients with a normal NMR, SPECT showed focal abnormalities. Although clinical history and a careful description of the seizures are the most valuable information in partial seizure disorders, SPECT imaging gives valuable additional information, which might target treatment. SPECT was superior to CT and NMR with respect to the depiction of some kind of abnormality. (author)

  1. Regional cerebral blood flow analysis of vascular dementia by the single photon emission computed tomography

    International Nuclear Information System (INIS)

    Miyakawa, Kouichi; Watanabe, Sho; Suzuki, Michiyo; Kamijima, Gonbei

    1989-01-01

    In order to evaluate the relationship between the regional cerebral blood flow (CBF) and cerebrovascular dementia, eleven patients with vascular dementia and eight patients with non-demented infarction were studied and regional CBF were measured quantitatively with single photon emission computed tomography (SPECT) by using N-isopropyl-p-(I-123) iodoamphetamine. All cases were basal infarction and vascular dementia were diagnosed by less than 21.5 of the Hasegawa's dementia score and more than 7 of Hachinsk's ischemic score. The results of the present study were as follows: (1) Cerebrovascular dementia showed lower mean CBF value compared with non-demented group. (2) Regional CBF of bilateral frontal areas and affected basal ganglia were significantly reduced than occipital area in the dementia group. (3) A comparison of regional CBF and the Hasegawa's dementia score revealed a statistically significant correlation at the bilateral frontal areas in the dementia group. It is possible that measuring the regional CBF quantitatively by IMP-SPECT is useful for clinical analysis of vascular dementia. (author)

  2. [Restoration filtering based on projection power spectrum for single-photon emission computed tomography].

    Science.gov (United States)

    Kubo, N

    1995-04-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.

  3. Two-dimensional restoration of single photon emission computed tomography images using the Kalman filter

    International Nuclear Information System (INIS)

    Boulfelfel, D.; Rangayyan, R.M.; Kuduvalli, G.R.; Hahn, L.J.; Kloiber, R.

    1994-01-01

    The discrete filtered backprojection (DFBP) algorithm used for the reconstruction of single photon emission computed tomography (SPECT) images affects image quality because of the operations of filtering and discretization. The discretization of the filtered backprojection process can cause the modulation transfer function (MTF) of the SPECT imaging system to be anisotropic and nonstationary, especially near the edges of the camera's field of view. The use of shift-invariant restoration techniques fails to restore large images because these techniques do not account for such variations in the MTF. This study presents the application of a two-dimensional (2-D) shift-variant Kalman filter for post-reconstruction restoration of SPECT slices. This filter was applied to SPECT images of a hollow cylinder phantom; a resolution phantom; and a large, truncated cone phantom containing two types of cold spots, a sphere, and a triangular prism. The images were acquired on an ADAC GENESYS camera. A comparison was performed between results obtained by the Kalman filter and those obtained by shift-invariant filters. Quantitative analysis of the restored images performed through measurement of root mean squared errors shows a considerable reduction in error of Kalman-filtered images over images restored using shift-invariant methods

  4. Single photon emission computed tomography in the diagnosis of Alzheimer's disease

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin'e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko

    1997-01-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer's disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with 123 I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject's clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson's disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  5. Forensic applications of cerebral single photon emission computed tomography in mild traumatic brain injury.

    Science.gov (United States)

    Wortzel, Hal S; Filley, Christopher M; Anderson, C Alan; Oster, Timothy; Arciniegas, David B

    2008-01-01

    Traumatic brain injury (TBI) is a substantial source of mortality and morbidity world wide. Although most such injuries are relatively mild, accurate diagnosis and prognostication after mild TBI are challenging. These problems are complicated further when considered in medicolegal contexts, particularly civil litigation. Cerebral single photon emission computed tomography (SPECT) may contribute to the evaluation and treatment of persons with mild TBI. Cerebral SPECT is relatively sensitive to the metabolic changes produced by TBI. However, such changes are not specific to this condition, and their presence on cerebral SPECT imaging does not confirm a diagnosis of mild TBI. Conversely, the absence of abnormalities on cerebral SPECT imaging does not exclude a diagnosis of mild TBI, although such findings may be of prognostic value. The literature does not demonstrate consistent relationships between SPECT images and neuropsychological testing or neuropsychiatric symptoms. Using the rules of evidence shaped by Daubert v. Merrell Dow Pharmaceuticals, Inc., and its progeny to analyze the suitability of SPECT for forensic purposes, we suggest that expert testimony regarding SPECT findings should be admissible only as evidence to support clinical history, neuropsychological test results, and structural brain imaging findings and not as stand-alone diagnostic data.

  6. Single-photon emission computed tomographic findings and motor neuron signs in amyotrophic lateral sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Terao, Shin-ichi; Sobue, Gen; Higashi, Naoki; Takahashi, Masahiko; Suga, Hidemichi; Mitsuma, Terunori [Aichi Medical Univ., Nagakute (Japan)

    1995-03-01

    {sup 123}I-amphetamine-single photon emission computed tomography (SPECT) was performed on 16 patients with amyotrophic lateral sclerosis (ALS) to investigate the correlation between regional cerebral blood flow (rCBF) and upper motor neuron signs. Significant decreased blood flow less than 2 SDs below the mean of controls was observed in the frontal lobe in 4 patients (25%) and in the frontoparietal lobe including the cortical motor area in 4 patients, respectively. The severity of extermity muscular weakness was significantly correlate with decrease in blood flow through the frontal lobe (p<0.05) and through the frontoparietal lobe (p<0.001). A significant correlation was also noted to exist between the severity of bulbar paralysis and decrease in blood flow through the frontoparietal lobe. No correlation, however, was observed between rCBF and severity of spasticity, presence or absence of Babinski`s sign and the duration of illness. Although muscular weakness in the limbs and bulbar paralysis are not pure upper motor neuron signs, the observed reduction in blood flow through the frontal or frontoparietal lobes appears to reflect extensive progression of functional or organic lesions of cortical neurons including the motor area. (author).

  7. Single-photon emission computed tomographic findings and motor neuron signs in amyotrophic lateral sclerosis

    International Nuclear Information System (INIS)

    Terao, Shin-ichi; Sobue, Gen; Higashi, Naoki; Takahashi, Masahiko; Suga, Hidemichi; Mitsuma, Terunori

    1995-01-01

    123 I-amphetamine-single photon emission computed tomography (SPECT) was performed on 16 patients with amyotrophic lateral sclerosis (ALS) to investigate the correlation between regional cerebral blood flow (rCBF) and upper motor neuron signs. Significant decreased blood flow less than 2 SDs below the mean of controls was observed in the frontal lobe in 4 patients (25%) and in the frontoparietal lobe including the cortical motor area in 4 patients, respectively. The severity of extermity muscular weakness was significantly correlate with decrease in blood flow through the frontal lobe (p<0.05) and through the frontoparietal lobe (p<0.001). A significant correlation was also noted to exist between the severity of bulbar paralysis and decrease in blood flow through the frontoparietal lobe. No correlation, however, was observed between rCBF and severity of spasticity, presence or absence of Babinski's sign and the duration of illness. Although muscular weakness in the limbs and bulbar paralysis are not pure upper motor neuron signs, the observed reduction in blood flow through the frontal or frontoparietal lobes appears to reflect extensive progression of functional or organic lesions of cortical neurons including the motor area. (author)

  8. Quantitation of postexercise lung thallium-201 uptake during single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kahn, J.K.; Carry, M.M.; McGhie, I.; Pippin, J.J.; Akers, M.S.; Corbett, J.R.

    1989-01-01

    To test the hypothesis that analysis of lung thallium uptake measured during single photon emission computed tomography (SPECT) yields supplementary clinical information as reported for planar imaging, quantitative analysis of lung thallium uptake following maximal exercise was performed in 40 clinically normal subjects (Group 1) and 15 angiographically normal subjects (Group 2). Lung thallium uptake was measured from anterior projection images using a ratio of heart-to-lung activities. Seventy subjects with coronary artery disease (CAD) (Group 3) determined by angiography (greater than or equal to 70% luminal stenosis) underwent thallium perfusion SPECT. Thirty-nine percent of these subjects had multivessel and 61% had single vessel CAD. Lung thallium uptake was elevated in 47 of 70 (67%) Group 3 subjects. Group 3 subjects with elevated lung thallium uptake did not differ from Group 3 subjects with normal lung thallium uptake with respect to extent or distribution of coronary artery disease, left ventricular function, or severity of myocardial ischemia as determined by exercise and redistribution thallium SPECT. Thus, the measurement of thallium lung uptake from anterior projection images obtained during SPECT frequently identifies patients with CAD, but it may not provide supplementary information regarding the extent of myocardial ischemia or ventricular dysfunction

  9. Time sequential single photon emission computed tomography studies in brain tumour using thallium-201

    International Nuclear Information System (INIS)

    Ueda, Takashi; Kaji, Yasuhiro; Wakisaka, Shinichiro; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi; Futami, Shigemi

    1993-01-01

    Time sequential single photon emission computed tomography (SPECT) studies using thallium-201 were performed in 25 patients with brain tumours to evaluate the kinetics of thallium in the tumour and the biological malignancy grade preoperatively. After acquisition and reconstruction of SPECT data from 1 min post injection to 48 h (1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 15-20 min, followed by 4-6, 24 and 48 h), the thallium uptake ratio in the tumour versus the homologous contralateral area of the brain was calculated and compared with findings of X-ray CT, magnetic resonance imaging, cerebral angiography and histological investigations. Early uptake of thallium in tumours was related to tumour vascularity and the disruption of the blood-brain barrier. High and rapid uptake and slow reduction of thallium indicated a hypervascular malignant tumour; however, high and rapid uptake but rapid reduction of thallium indicated a hypervascular benign tumour, such as meningioma. Hypovascular and benign tumours tended to show low uptake and slow reduction of thallium. Long-lasting retention or uptake of thallium indicates tumour malignancy. (orig.)

  10. Imaging of lesions in the posterior cranial fossa using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kawakami, Michiro; Uesugi, Yasuo; Higashikawa, Masahiko; Ochi, Mari; Makimoto, Kazuo; Takahashi, Hiroaki; Shin, Akinori; Utsunomiya, Keita; Akagi, Hiroaki

    1988-01-01

    Lesions in the posterior cranial fossa were visualized by single photon emission computed tomography (SPECT) with 123 I-IMP (N-isopropyl-p- 123 I-iodoamphetamine) and 99m Tc-HM-PAO ( 99m Tc-hexametylpropyleneamine oxime). It is generally held that these radiopharmaceuticals penetrate the walls of cerebral blood vessels and that their accumulations in the brain tissue may reflect the cerebral blood flow. Six patients with lesions in the central nervous system all showed wider areas of abnormality in SPECT than in X-ray CT, indicating a larger lesion of blood flow disturbance. In the next series of 11 patients with vertigo or dizziness of unknown etiology, eight had abnormal findings in the scan with 123 I-IMP as did four of the nine in the scan with 99m Tc-HM-PAO. Thus, most patients with dizziness of unknown etiology may have some vertebral blood flow disorder, which in some cases is not clearly diagnosed by conventional vestibular examinations or even by X-ray CT scan. The accuracy of the diagnostic measures for otoneurological problems awaits further studies of their sensitivity and specificity. (author)

  11. Cardiac single-photon emission-computed tomography using combined cone-beam/fan-beam collimation

    International Nuclear Information System (INIS)

    Gullberg, Grant T.; Zeng, Gengsheng L.

    2004-01-01

    The objective of this work is to increase system sensitivity in cardiac single-photon emission-computed tomography (SPECT) studies without increasing patient imaging time. For imaging the heart, convergent collimation offers the potential of increased sensitivity over that of parallel-hole collimation. However, if a cone-beam collimated gamma camera is rotated in a planar orbit, the projection data obtained are not complete. Two cone-beam collimators and one fan-beam collimator are used with a three-detector SPECT system. The combined cone-beam/fan-beam collimation provides a complete set of data for image reconstruction. The imaging geometry is evaluated using data acquired from phantom and patient studies. For the Jaszazck cardiac torso phantom experiment, the combined cone-beam/fan-beam collimation provided 1.7 times greater sensitivity than standard parallel-hole collimation (low-energy high-resolution collimators). Also, phantom and patient comparison studies showed improved image quality. The combined cone-beam/fan-beam imaging geometry with appropriate weighting of the two data sets provides improved system sensitivity while measuring sufficient data for artifact free cardiac images

  12. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  13. Single photon emission computed tomography and albumin colloid imaging of the liver

    International Nuclear Information System (INIS)

    Croft, B.Y.; Teates, C.D.; Honeyman, J.C.

    1984-01-01

    A single photon emission computed tomography (ECT) system using the GE 400T Anger camera with 37 PM tubes and the SPETS software has been installed in our clinical laboratory. It has been used in the study of liver imaging with Tc-99m albumin colloid and other agents. The object of the study is to define what improvement in liver diagnosis might be made using ECT. Patients were injected with 3-4 mCi (ca 120 MBq) of colloid; five standard liver-spleen views and a 64-image ECT study were acquired. The ECT images were acquired either in a circle of the radius of the longer transverse axis of the patient or in an ellipse to match the patient contour. Studies were corrected for the attenuation of the Tc-99m gamma rays by tissue. A series of normal and abnormal patients have been studied and the data analyzed. The significant change in the technique of ECT imaging is the elliptical motion of the camera head which allows a better approximation of the patient contour and improves the spatial resolution of the images. (orig.)

  14. Quantification of leg muscle perfusion using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Oshima, M.; Akanabe, H.; Sakuma, S.; Yano, T.; Nishikimi, N.; Shionoya, S.

    1989-01-01

    The purpose of this study is to quantify leg muscle perfusion with 201 Tl single photon emission computed tomography (SPECT). Six normal controls and 21 patients with peripheral arterial disease underwent this examination. Thallium-201 leg SPECT of both stress and redistribution was performed using a dual-headed digital gamma camera. Each slice of transverse images was normalized with pixels and whole-body counts. In normal controls, the activity of posterior tibial muscle components was significantly higher than that of anterior tibial muscle components (p less than 0.001). In 14 components, where patients had insignificant lesions, profile curves were normal in 10 (71%). In 62 components, where patients had arteriographically significant lesions, stress profile curves were abnormal in 57 (92%) compared with normal controls. Approximately, in half (28/62) components which had significant lesions, profile curves showed redistribution after 3 hr compared with normal redistribution curves. In three patients who underwent successful bypass graftings, the activity of each muscle component returned to a normal range

  15. Brain Single Photon Emission Computed Tomography in Anosmic Subjects Ater Closed Head Trauma

    Directory of Open Access Journals (Sweden)

    Roozbeh Banan

    2011-01-01

    Full Text Available Anosmia following head trauma is relatively common and in many cases is persistent and irreversible. The ability to objectively measure such a decline in smelling, for both clinical and medicolegal goals, is very important. The aim of this study was to find results of brain Single Photon Emission Computed Tomography (SPECT in anosmic subjects after closed head trauma. This case-control cross sectional study was conducted in a tertiary referral University Hospital. The brain perfusion state of nineteen anosmic patients and thirteen normal controls was evaluated by means of the SPECT with 99mtc- ECD infusion- before and after olfactory stimulation. The orbitofrontal lobe of the brain was assumed as the region of interest and changes in perfusion of this area before and after the stimulations were compared in two groups. The mean of brain perfusion in controls before and after the stimulation was 8.26% ± 0.19% and 9.89% ± 0.54%, respectively (P < 0.0001. Among patients group, these quantities were 7.97% ± 1.05% and 8.49% ± 1.5%, respectively (P < 0.004. The difference between all the measures in cases and controls were statistically significant (P < 0.0001. There were no differences in age and sex between two groups. The brain SPECT is an objective technique suitable for evaluating anosmia following the head trauma and it may be used with other diagnostic modalities

  16. Musicogenic epilepsy: review of the literature and case report with ictal single photon emission computed tomography.

    Science.gov (United States)

    Wieser, H G; Hungerbühler, H; Siegel, A M; Buck, A

    1997-02-01

    We report a case of musicogenic epilepsy with ictal single photon emission computed tomography (SPECT) study and discuss the findings of this patient in the context of 76 cases with musicogenic epilepsy described in the literature and seven other cases followed in Zurich. We analyzed the 83 patients according to the precipitating musical factors, type of epilepsy, presumed localization of seizure onset, and demographic data. Fourteen of 83 patients (17%) had seizures triggered exclusively by music. At time of examination, music was the only known precipitating stimulus in 65 of 83 patients (78%). Various characteristics of the musical stimulus were significant, e.g., musical category, familiarity, and instruments. Musicogenic epilepsy is a particular form of epilepsy with a strong correlation to the temporal lobe and a right-sided preponderance. A high musial standard might predispose for musicogenic epilepsy. Moreover, the majority of cases do not fall into the category of a strictly defined "reflex epilepsy," but appear to depend on the indermediary of a certain emotional reaction mediated through limbic mesial temporal lobe structures.

  17. Restoration filtering based on projection power spectrum for single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kubo, Naoki

    1995-01-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical 'least squares filter' theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the 'Butterworth' filtering method (cut-off frequency of 0.15 cycles/pixel), and 'Wiener' filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99m Tc filled cylinder, were used. NMSE of the 'Butterworth' filter, 'Wiener' filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images. (author)

  18. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  19. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    International Nuclear Information System (INIS)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves; Delluc, Aurelien; Couturaud, Francis; Le Gal, Gregoire

    2014-01-01

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  20. An x-ray-based capsule for colorectal cancer screening incorporating single photon counting technology

    Science.gov (United States)

    Lifshitz, Ronen; Kimchy, Yoav; Gelbard, Nir; Leibushor, Avi; Golan, Oleg; Elgali, Avner; Hassoon, Salah; Kaplan, Max; Smirnov, Michael; Shpigelman, Boaz; Bar-Ilan, Omer; Rubin, Daniel; Ovadia, Alex

    2017-03-01

    An ingestible capsule for colorectal cancer screening, based on ionizing-radiation imaging, has been developed and is in advanced stages of system stabilization and clinical evaluation. The imaging principle allows future patients using this technology to avoid bowel cleansing, and to continue the normal life routine during procedure. The Check-Cap capsule, or C-Scan ® Cap, imaging principle is essentially based on reconstructing scattered radiation, while both radiation source and radiation detectors reside within the capsule. The radiation source is a custom-made radioisotope encased in a small canister, collimated into rotating beams. While traveling along the human colon, irradiation occurs from within the capsule towards the colon wall. Scattering of radiation occurs both inside and outside the colon segment; some of this radiation is scattered back and detected by sensors onboard the capsule. During procedure, the patient receives small amounts of contrast agent as an addition to his/her normal diet. The presence of contrast agent inside the colon dictates the dominant physical processes to become Compton Scattering and X-Ray Fluorescence (XRF), which differ mainly by the energy of scattered photons. The detector readout electronics incorporates low-noise Single Photon Counting channels, allowing separation between the products of these different physical processes. Separating between radiation energies essentially allows estimation of the distance from the capsule to the colon wall, hence structural imaging of the intraluminal surface. This allows imaging of structural protrusions into the colon volume, especially focusing on adenomas that may develop into colorectal cancer.

  1. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almquist, H

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correctionwere artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 {+-} 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer {sup 133}Xe. Because of the low energy of {sup 133}Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study.

  2. Dynamic single photon emission computed tomography-basic principles and cardiac applications

    International Nuclear Information System (INIS)

    Gullberg, Grant T; Reutter, Bryan W; Maltz, Jonathan S; Budinger, Thomas F; Sitek, Arkadiusz

    2010-01-01

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging

  3. Effectiveness of revascularization surgery evaluated by proton magnetic resonance spectroscopy and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Masaaki; Ueda, Shin; Hondo, Hideki; Matsumoto, Keizo; Harada, Masafumi [Tokushima Univ. (Japan). School of Medicine

    1996-08-01

    Proton magnetic resonance spectroscopy (MRS) and single photon emission computed tomography (SPECT) were used to evaluate chronic ischemic regions in 26 stroke patients before and 1, 3, and 6 months after revascularization surgery. The volume of interest for proton MRS was placed in an area including part of the frontal and temporal opercula, insular cortex, and basal ganglia. Twenty healthy volunteers served as controls for proton MRS. Patients were divided into three groups according to the preoperative proton MRS. Group A (n=12) had significantly lower N-acetylaspartate/choline (NAA/Cho) and N-acetylaspartate/creatine (NAA/Cr) ratios on the operative side compared to those on the contralateral side, and also lower than those in normal subjects. In seven patients in Group A, postoperative serial proton MRS demonstrated no recovery of these ratios on the operative side. However, proton MRS of the other five patients indicated gradual improvement in these ratios on the operative side at 3 to 6 months after surgery, and SPECT indicated an increase in cerebral blood flow on the operative side in four of these five patients. In Group B (n=9), proton MRS and SPECT showed no laterality before revascularization and no remarkable change during the postoperative course. In Group C (n=5), NAA/Cho or NAA/Cr decreased on the contralateral side preoperatively. Two patients showed fluctuating values of NAA/Cho or NAA/Cr during the postoperative period. Serial proton MRS and SPECT Studies may be useful for the evaluation of revascularization surgery on ischemic regions. The efficacy of revascularization surgery on the metabolism may appear gradually within 3-6 months. (author)

  4. Single-photon emission computed tomography for the assessment of ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gonzalez, Patricio; Dussaillant, Gaston; Gutierrez, Daniela; Berrocal, Isabel; Alay, Rita; Otarola, Sonia

    2013-01-01

    Background: Single-photon emission computed tomography (SPECT) can be used as a non-invasive tool for the assessment of coronary perfusion. Aim: To assess ventricular perfusion and function by SPECT in patients with single vessel coronary artery disease. Material and Methods: Among patients with indications for a coronary artery angiography, those with significant lesions in one vessel, were selected for the study. Within 24 hours, cardiac SPECT examinations on basal conditions and after high doses of dipyridamole, were performed. SPECT data from 38 patients with a low probability of coronary artery disease was used for comparisons. Results:Ten patients aged 61 ± 8 years (seven men) were studied. Visual analysis of SPECT revealed signs suggestive of ischemia in eight patients. The remaining two patients did not have perfusion disturbances. SPECT detected eight of ten abnormal vessels reported in the coronary artery angiography. There were two false negative results Summed stress, summed rest and summed difference scores were 9.78 ± 6.51, 3.22 ± 5.07 and 6.33 ± 4.97, respectively. The ejection fractions under stress and at rest were 53 ± 11.7% and 61 ± 15.7% respectively (p ≤ 0.01). The figures for the control group were 69.1 ± 13.5% and 75.2 ± 12.04% respectively (significantly different from patients). Two patients had a summed motion score above 14.9. Likewise, two patients had a summed thickening score above 10.9. Conclusions: SPECT detected 80% of coronary lesions found during coronary artery angiography. Visual analysis of perfusion is highly reliable for diagnosis. Quantitative parameters must be considered only as reference parameters

  5. Reverse redistribution in dipyridamole-loading thallium-201 images using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Mori, Kiyoo; Masuda, Masanosuke; Bunko, Hisashi.

    1986-01-01

    Dipyridamole was infused intravenously at a rate of 0.142 mg/kg per min for four min, and a stress image was obtained 10 min after the injection of two mCi 201 Tl. The myocardial image of Tl was analyzed by single photon emission computed tomography and its washout rate was calculated by the segmental ROI method. Myocardial function and the motion of the left ventricular wall were analyzed by 99m Tc-RBC-gated cardiac pool imaging. Reverse redistribution was noted in 27 (21.6 %) of 125 consecutive Tl dipyridamole and redistribution myocardial imaging studies. The stress image demonstrated normal perfusion (group 1) and reduced perfusion (group 2) of Tl. Group 1 consisted of 17 patients with diabetes mellitus, supraventricular arrhythmias, hypertension, and others. Group 2 consisted of 10 patients with subendocardial infarction, diabetes mellitus, and hypertension, and others. The percentage prevalence of reverse redistribution among patients with supraventricular arrhythmia was 62.5 % (five of eight patients), with subendocardial infarction 60.0 % (three of five), with hypertension 42.8 % (six of 14), and with diabetes mellitus 40.0 % (eight of 20), while in those with transmyocardial infarction and angina pectoris no reverse redistribution percentage was found. The washout rate of Tl in normal perfusion areas was 44.0 ± 12.8 %, the reverse redistribution of group 1 was 47.4 ± 12.8 %, and of group 2 was 51.2 ± 8.2 %. The washout rate of the reverse redistribution of group 2 was significantly greater than that of the normal areas. In gated cardiac pool imaging, patients in group 2 had significantly larger areas showing abnormal contraction of the left ventricular wall and significantly lower ejection fraction than did group 1. In the electrocardiogram ST segment depression was noted more frequently in group 2 than group 1. No Q wave was present in the corresponding reverse redistribution area. (J.P.N.)

  6. Dynamic single photon emission computed tomography-basic principles and cardiac applications

    Energy Technology Data Exchange (ETDEWEB)

    Gullberg, Grant T; Reutter, Bryan W; Maltz, Jonathan S; Budinger, Thomas F [E O Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Sitek, Arkadiusz, E-mail: gtgullberg@lbl.go [Brigham and Women' s Hospital and Harvard Medical School, Boston, MA (United States)

    2010-10-21

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging

  7. TOPICAL REVIEW: Dynamic single photon emission computed tomography—basic principles and cardiac applications

    Science.gov (United States)

    Gullberg, Grant T.; Reutter, Bryan W.; Sitek, Arkadiusz; Maltz, Jonathan S.; Budinger, Thomas F.

    2010-10-01

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging

  8. Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography.

    Science.gov (United States)

    Abidov, Aiden; Hachamovitch, Rory; Rozanski, Alan; Hayes, Sean W; Santos, Marcia M; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Friedman, John D; Germano, Guido; Berman, Daniel S

    2004-09-01

    The aim of this research was to determine whether presence of atrial fibrillation (AF) provides incremental prognostic information relative to myocardial perfusion single-photon emission computed tomography (MPS) with respect to risk of cardiac death (CD). The prognostic significance of AF in patients undergoing MPS is not known. A total of 16,048 consecutive patients undergoing MPS were followed-up for a mean of 2.21 +/- 1.15 years for the development of CD. Of those, 384 patients (2.4%) had AF. Cox proportional hazards method was used to compare clinical and perfusion data for the prediction of CD in patients with and without AF. Atrial fibrillation was a significant predictor of CD in patients with normal (1.6% per year vs. 0.4% per year in non-AF patients), mildly abnormal (6.3% per year vs. 1.2% per year), and severely abnormal MPS (6.4% per year vs. 3.7% per year) (p < 0.001 for all). By multivariable analysis, AF patients had worse survival (p = 0.001) even after adjustment for the variables most predictive of CD: age, diabetes, shortness of breath, use of vasodilator stress, rest heart rate, and the nuclear variables. In the 4,239 patients with left ventricular ejection fraction evaluated by gated MPS, AF demonstrated incremental prognostic value not only over clinical and nuclear variables, but also over left ventricular ejection in predicting CD (p = 0.014). The presence of AF independently increases the risk of cardiac events over perfusion and function variables in patients undergoing MPS. Patients with AF have a high risk of CD, even when MPS is only mildly abnormal. Whether patients with AF and mildly abnormal MPS constitute a group more deserving of early referral to cardiac catheterization is a question warranting further study.

  9. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Almquist, H.

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correction were artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 ± 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer 133 Xe. Because of the low energy of 133 Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study

  10. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Ichiseki, Hajime; Terashi, Akiro; Hamamoto, Makoto; Miyazaki, Tokuzo.

    1995-01-01

    We have performed single photon emission computed tomography (SPECT) with 99m Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author)

  11. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ichiseki, Hajime; Terashi, Akiro [Nippon Medical School, Tokyo (Japan); Hamamoto, Makoto; Miyazaki, Tokuzo

    1995-12-01

    We have performed single photon emission computed tomography (SPECT) with {sup 99m}Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author).

  12. Usefulness of isoproterenol stress thallium-201 myocardial single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi

    1990-01-01

    Twenty patients complaining of chest pain were referred for isoproterenol stress thallium-201 myocardial single photon emission computed tomography (ISO-SPECT). The findings were compared with those obtained from isoproterenol stress ECG testing (ISO-ECG) and exercise SPECT (EX-SPECT). Isoproterenol was iv injected in a dose of 0.02 μg/kg/min. The amount was continuously increased until limited by chest pain, ST depression, and/or determined heart rate criteria. The patients were scanned immediately and three hours after giving isoproterenol. Transient hypoperfusion was regarded as myocardial ischemia. Washout rate, obtained from circumferential profile analysis on the short axis SPECT images, was expressed by Bull's eye display. Fifteen patients with angiographically significant stenosis of 75% or greater were diagnosed as having coronary artery disease (CAD). The other five patients had normal coronary artery (NC). In diagnosing CAD, ISO-ECG and ISO-SPECT had a sensitivity of 80% and 92%, respectively. Because the NC group had negative findings for redistribution on ISO-SPECT, the specificy of ISO-SPECT seemed to be high. For multi-vessel disease, redistribution on ISO-SPECT tended to underestimate coronary lesions. The underestimation was, however, corrected by calculating washout rate. For evaluable 11 patients undergoing concurrent EX-SPECT, ISP-SPECT was equivalent or superior to EX-SPECT in diagnostic sensitivity. None of the patients had severe side effects of isoproterenol, except for some having arrhythmia. The results indicated that ISO-SPECT is a safe, high sensitive diagnostic approach that is comparable to Ex-SPECT. (N.K.)

  13. I-123 iomazenil single photon emission computed tomography for detecting loss of neuronal integrity in patients with traumatic brain injury

    OpenAIRE

    Abiko, Kagari; Ikoma, Katsunori; Shiga, Tohru; Katoh, Chietsugu; Hirata, Kenji; Kuge, Yuji; Kobayashi, Kentaro; Tamaki, Nagara

    2017-01-01

    Background Traumatic brain injury (TBI) causes brain dysfunction in many patients. Using C-11 flumazenil (FMZ) positron emission tomography (PET), we have detected and reported the loss of neuronal integrity, leading to brain dysfunction in TBI patients. Similarly to FMZ PET, I-123 iomazenil (IMZ) single photon emission computed tomography (SPECT) is widely used to determine the distribution of the benzodiazepine receptor (BZR) in the brain cortex. The purpose of this study is to examine whet...

  14. Brain hypoperfusion on Tc-99m-ethylene dicysteine diethyl ester single-photon emission computed tomography in Hashimoto's encephalopathy

    OpenAIRE

    Grande, Mar?a Luz Dom?nguez; Constantino, Ana; Rayo, Juan Ignacio; Serrano, Justo; Infante, Jose Rafael; Garcia, Lucia; Duran, Carmen

    2013-01-01

    We present a 17-year-old female, previously diagnosed of autoimmune hyperthyroidism who had an acute neurological episode and presented high antithyroid antibodies titers, cerebral spinal fluid and electroencephalogram changes. Tc-99m ethylene dicysteine diethyl ester brain single-photon emission computed tomography (SPECT) showed global and patchy hypoperfusion. With glucocorticoid therapy, clinical symptoms disappeared; there was a decrease in antithyroid antibody levels and repeat brain SP...

  15. Brain hypoperfusion on Tc-99m-ethylene dicysteine diethyl ester single-photon emission computed tomography in Hashimoto's encephalopathy

    International Nuclear Information System (INIS)

    Grande, María Luz Domínguez; Rayo, Juan Ignacio; Serrano, Justo; Infante, Jose Rafael; Garcia, Lucia; Duran, Carmen; Constantino, Ana

    2013-01-01

    We present a 17-year-old female, previously diagnosed of autoimmune hyperthyroidism who had an acute neurological episode and presented high antithyroid antibodies titers, cerebral spinal fluid and electroencephalogram changes. 99m Tc ethylene dicysteine diethyl ester brain single-photon emission computed tomography (SPECT) showed global and patchy hypoperfusion. With glucocorticoid therapy, clinical symptoms disappeared; there was a decrease in antithyroid antibody levels and repeat brain SPECT revealed improvement of perfusion. (author)

  16. Physical factors affecting single photon emission computed tomography (SPECT) applied in nuclear medicine

    International Nuclear Information System (INIS)

    Farag, H.I.; Khalil, W.A.; Hassan, R.A.

    2003-01-01

    many physical factors degrade single photon emission computed tomography (SPECT) images both qualitatively and quantitatively. Physical properties important for the assessment of the potential of emission computed tomography implemented by collimated detector systems include sensitivity, statistical and angular sampling requirements, attenuation compensation, resolution, uniformity, and multisection design constraints. SPECT has highlighted the used to improve gamma camera performance. Flood field nonuniformity is translated into tomographic the need to improve gamma camera performance. Flood field nonuniformity is translated into tomographic images as major artifacts because it distorts the data obtained at each projection. Also, poor energy resolution translates directly into degraded spatial resolution through reduced ability to reject scattered photons on the basic of pluses height analysis. The aim of this work is study the different and most important acquisition and processing parameters, which affect the quality of the SPECT images. The present study investigates the various parameters effecting SPECT images and experimental results demonstrate that: daily uniformity checks and evaluation are essential to ensure that the SPECT system is working properly. The Core used in the reconstruction process could be correct to avoid data misalignment. 60 mumblers of views gave the best image quality, rather than 20 or 30 views. Time per view (TPV) 30 or 20 sec gave a good image quality, rather than high-resolution collimator, is recommended in order to provide good spatial resolution. On the other hand patient motion could cause serious reconstruction artifacts. A cine display is recommended to identify movement artifacts. In the case of matrix size, matrix 128x128 give the best resolution than matrix 64x64. Energy window width, 15% compared with the standard 20% improved the resolution. Butter worth filter (cut off 0.57 cyc/cm with order 6 ) give the best resolution

  17. Single photon emission computed tomography (SPECT of anxiety disorders before and after treatment with citalopram

    Directory of Open Access Journals (Sweden)

    Seedat Soraya

    2004-10-01

    Full Text Available Abstract Background Several studies have now examined the effects of selective serotonin reuptake inhibitor (SSRI treatment on brain function in a variety of anxiety disorders including obsessive-compulsive disorder (OCD, posttraumatic stress disorder (PTSD, and social anxiety disorder (social phobia (SAD. Regional changes in cerebral perfusion following SSRI treatment have been shown for all three disorders. The orbitofrontal cortex (OFC (OCD, caudate (OCD, medial pre-frontal/cingulate (OCD, SAD, PTSD, temporal (OCD, SAD, PTSD and, thalamic regions (OCD, SAD are some of those implicated. Some data also suggests that higher perfusion pre-treatment in the anterior cingulate (PTSD, OFC, caudate (OCD and antero-lateral temporal region (SAD predicts subsequent treatment response. This paper further examines the notion of overlap in the neurocircuitry of treatment and indeed treatment response across anxiety disorders with SSRI treatment. Methods Single photon emission computed tomography (SPECT using Tc-99 m HMPAO to assess brain perfusion was performed on subjects with OCD, PTSD, and SAD before and after 8 weeks (SAD and 12 weeks (OCD and PTSD treatment with the SSRI citalopram. Statistical parametric mapping (SPM was used to compare scans (pre- vs post-medication, and responders vs non-responders in the combined group of subjects. Results Citalopram treatment resulted in significant deactivation (p = 0.001 for the entire group in the superior (t = 4.78 and anterior (t = 4.04 cingulate, right thalamus (t = 4.66 and left hippocampus (t = 3.96. Deactivation (p = 0.001 within the left precentral (t = 4.26, right mid-frontal (t = 4.03, right inferior frontal (t = 3.99, left prefrontal (3.81 and right precuneus (t= 3.85 was more marked in treatment responders. No pattern of baseline activation distinguished responders from non-responders to subsequent pharmacotherapy. Conclusions Although each of the anxiety disorders may be mediated by different

  18. Single-photon sources

    International Nuclear Information System (INIS)

    Lounis, Brahim; Orrit, Michel

    2005-01-01

    The concept of the photon, central to Einstein's explanation of the photoelectric effect, is exactly 100 years old. Yet, while photons have been detected individually for more than 50 years, devices producing individual photons on demand have only appeared in the last few years. New concepts for single-photon sources, or 'photon guns', have originated from recent progress in the optical detection, characterization and manipulation of single quantum objects. Single emitters usually deliver photons one at a time. This so-called antibunching of emitted photons can arise from various mechanisms, but ensures that the probability of obtaining two or more photons at the same time remains negligible. We briefly recall basic concepts in quantum optics and discuss potential applications of single-photon states to optical processing of quantum information: cryptography, computing and communication. A photon gun's properties are significantly improved by coupling it to a resonant cavity mode, either in the Purcell or strong-coupling regimes. We briefly recall early production of single photons with atomic beams, and the operation principles of macroscopic parametric sources, which are used in an overwhelming majority of quantum-optical experiments. We then review the photophysical and spectroscopic properties and compare the advantages and weaknesses of various single nanometre-scale objects used as single-photon sources: atoms or ions in the gas phase and, in condensed matter, organic molecules, defect centres, semiconductor nanocrystals and heterostructures. As new generations of sources are developed, coupling to cavities and nano-fabrication techniques lead to improved characteristics, delivery rates and spectral ranges. Judging from the brisk pace of recent progress, we expect single photons to soon proceed from demonstrations to applications and to bring with them the first practical uses of quantum information

  19. The baboon model under anaesthesia for in vivo cerebral blood flow studies using single photon emission computed tomographic (SPECT) techniques

    International Nuclear Information System (INIS)

    Dormehl, I.; Redelinghuys, F.; Hugo, N.; Oliver, D.; Pilloy, W.

    1992-01-01

    Single photon computed tomography of the brain can be useful in animal experimentation directed towards cerebral conditions. A well established and understood baboon model, necessarily under anaesthesia, could especially be valuable in such investigations. Six normal baboons were studied under various anesthetic agents and their combinations: ketamine, thiopentone, pentobarbitone and halothane. Cerebral blood flow (CBF) studies were performed with 99m Tc-HMPAO. CBF effects from various anaesthesia were detected, requiring careful choice of the anaesthesia for cerebral investigations. (author). 13 refs, 4 figs, 3 tabs

  20. The baboon model under anaesthesia for in vivo cerebral blood flow studies using single photon emission computed tomographic (SPECT) techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dormehl, I.; Redelinghuys, F.; Hugo, N. [Pretoria Univ. (South Africa); Oliver, D.; Pilloy, W. [Medical Univ. of Southern Africa (MEDUNSA), Pretoria (South Africa)

    1992-12-31

    Single photon computed tomography of the brain can be useful in animal experimentation directed towards cerebral conditions. A well established and understood baboon model, necessarily under anaesthesia, could especially be valuable in such investigations. Six normal baboons were studied under various anesthetic agents and their combinations: ketamine, thiopentone, pentobarbitone and halothane. Cerebral blood flow (CBF) studies were performed with {sup 99m}Tc-HMPAO. CBF effects from various anaesthesia were detected, requiring careful choice of the anaesthesia for cerebral investigations. (author). 13 refs, 4 figs, 3 tabs.

  1. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  2. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    Science.gov (United States)

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was dysfunction as well as a useful technique for predicting the prognosis of this condition.

  3. The use of filtering methods to compensate for constant attenuation in single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Budinger, T.F.

    1981-01-01

    A back projection of filtered projection (BKFIL) reconstruction algorithm is presented that is applicable to single-photon emission computed tomography (ECT) in the presence of a constant attenuating medium such as the brain. The filters used in transmission computed tomography (TCT)-comprised of a ramp multiplied by window functions-are modified so that the single-photon ECT filter is a function of the constant attenuation coefficient. The filters give good reconstruction results with sufficient angular and lateral sampling. With continuous samples the BKFIL algorithm has a point spread function that is the Hankel transform of the window function. The resolution and statistical properties of the filters are demonstrated by various simulations which assume an ideal detector response. Statistical formulas for the reconstructed image show that the square of the percent-root-mean-square (percent-rms) uncertainty of the reconstruction is inversely proportional to the total measured counts. The results indicate that constant attenuation can be compensated for by using an attenuation-dependent filter that reconstructs the transverse section reliably. Computer time requirements are two times that of conventional TCT or positron ECT and there is no increase in memory requirements

  4. Utility of Quantitative Parameters from Single-Photon Emission Computed Tomography/Computed Tomography in Patients with Destructive Thyroiditis

    Science.gov (United States)

    Kim, Ji-Young; Kim, Ji Hyun; Moon, Jae Hoon; Kim, Kyoung Min; Oh, Tae Jung; Lee, Dong-Hwa; So, Young

    2018-01-01

    Objective Quantitative parameters from Tc-99m pertechnetate single-photon emission computed tomography/computed tomography (SPECT/CT) are emerging as novel diagnostic markers for functional thyroid diseases. We intended to assess the utility of SPECT/CT parameters in patients with destructive thyroiditis. Materials and Methods Thirty-five destructive thyroiditis patients (7 males and 28 females; mean age, 47.3 ± 13.0 years) and 20 euthyroid patients (6 males and 14 females; mean age, 45.0 ± 14.8 years) who underwent Tc-99m pertechnetate quantitative SPECT/CT were retrospectively enrolled. Quantitative parameters from the SPECT/CT (%uptake, standardized uptake value [SUV], thyroid volume, and functional thyroid mass [SUVmean × thyroid volume]) and thyroid hormone levels were investigated to assess correlations and predict the prognosis for destructive thyroiditis. The occurrence of hypothyroidism was the outcome for prognosis. Results All the SPECT/CT quantitative parameters were significantly lower in the 35 destructive thyroiditis patients compared to the 20 euthyroid patients using the same SPECT/CT scanner and protocol (p thyroid-stimulating hormone (TSH) significantly correlated with %uptake (p = 0.004), SUVmean (p thyroid mass (p thyroiditis patients, 16 progressed to hypothyroidism. On univariate and multivariate analyses, only T3 levels were associated with the later occurrence of hypothyroidism (p = 0.002, exp(β) = 1.022, 95% confidence interval: 1.008 – 1.035). Conclusion Novel quantitative SPECT/CT parameters could discriminate patients with destructive thyroiditis from euthyroid patients, suggesting the robustness of the quantitative SPECT/CT approach. However, disease progression of destructive thyroiditis could not be predicted using the parameters, as these only correlated with TSH, but not with T3, the sole predictor of the later occurrence of hypothyroidism. PMID:29713225

  5. Sacrococcygeal chordoma: increased 99mTc methylene diphosphonate uptake on single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppuswamy; Bhattacharya, Anish; Harisankar, Chidambaram Natarajan Balasubramaniam; Mittal, Bhagwant Rai; Goni, Vijay

    2012-01-01

    Chordoma is a malignant tumor arising from the remnants of the notochord, and is the most frequent primitive tumor of the sacrum. While most sacral tumors show increased concentration of bone-seeking radiopharmaceuticals, chordomas usually exhibit decreased uptake. The authors present an image of a sacrococcygeal chordoma with osteolysis and increased uptake of 99m Tc methylene diphosphonate on planar and single photon emission computed tomography/computed tomography bone scintigraphy. (author)

  6. Cerebral perfusion inhomogeneities in schizophrenia demonstrated with single photon emission computed tomography and Tc99m-hexamethylpropyleneamineoxim

    International Nuclear Information System (INIS)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, C.; Medved, V.

    1989-01-01

    Cerebral blood flow was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim (HMPAO) and single photon emission computed tomography (SPECT) in 28 female schizophrenic patients (20 acute and 8 chronic) classified according to DSM-III. Eleven normals served as controls. The acute patients were classified according to positive and negative symptoms. Patients with predominantly positive symptoms showed by and large normal and homogeneous cerebral isotope uptake. Those with negative symptoms, and the chronic patients, showed inhomogeneous tracer uptake with multiple regions of hypoperfusion in slices 4-6 cm above the orbitomeatal line. The findings support in principle the notion that schizophrenia with negative or chronic symptoms does not affect the whole brain homogeneously. Brain imaging with Tc99m-HMPAO and SPECT might be used to distinguish various types of schizophrenia. (author)

  7. Three-dimensional SPECT [single photon emission computed tomography] reconstruction of combined cone beam and parallel beam data

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Jianying Li; Huili Wang; Coleman, R.E.

    1992-01-01

    Single photon emission computed tomography (SPECT) using cone beam (CB) collimation exhibits increased sensitivity compared with acquisition geometries using parallel (P) hole collimation. However, CB collimation has a smaller field-of-view which may result in truncated projections and image artifacts. A primary objective of this work is to investigate maximum likelihood-expectation maximization (ML-EM) methods to reconstruct simultaneously acquired parallel and cone beam (P and CB) SPECT data. Simultaneous P and CB acquisition can be performed with commercially available triple camera systems by using two cone-beam collimators and a single parallel-hole collimator. The loss in overall sensitivity (relative to the use of three CB collimators) is about 15 to 20%. The authors have developed three methods to combine P and CB data using modified ML-EM algorithms. (author)

  8. Utility of single photon emission computed tomography/computed tomography imaging in evaluation of chronic low back pain

    International Nuclear Information System (INIS)

    Harisankar, Chidambaram Natrajan Balasubramanian; Mittal, Bhagwant Rai; Bhattacharya, Anish; Singh, Paramjeet; Sen, Ramesh

    2012-01-01

    Abnormal morphologic findings in imaging were thought to explain the etiology of low back pain (LBP). However, it is now known that variety of morphologic abnormalities is noted even in asymptomatic individuals. Single photon emission computed tomography/computed tomography (SPECT/CT) could be used to differentiate incidental findings from clinically significant findings. This study was performed to define the SPECT/CT patterns in patients with LBP and to correlate these with clinical and magnetic resonance imaging (MRI) findings. Thirty adult patients with LBP of duration 3 months or more were prospectively evaluated in this study. Patients with known or suspected malignancy, trauma or infectious processes were excluded. A detailed history of sensory and motor symptoms and neurologic examination was performed. All the patients were subjected to MRI and bone scintigraphy with hybrid SPECT/CT of the lumbo-sacral spine within 1 month of each other. The patients were classified into those with and without neurologic symptoms, activity limitation. The findings of clinical examination and imaging were compared. MRI and SPECT/CT findings were also compared. Thirty patients (18 men and 12 women; mean age 38 years; range 17-64 years) were eligible for the study. Clinically, 14 of 30 (46%) had neurologic signs and or symptoms. Six of the 30 patients (20%) had positive straight leg raising test (SLRT). Twenty-two of the 30 patients (73%) had SPECT abnormality. Most frequent SPECT/CT abnormality was tracer uptake in the anterior part of vertebral body with osteophytes/sclerotic changes. Significant positive agreement was noted between this finding and MRI evidence of degenerative disc disease. Only 13% of patients had more than one abnormality in SPECT. All 30 patients had MRI abnormalities. The most frequent abnormality was degenerative disc disease and facet joint arthropathy. MRI showed single intervertebral disc abnormality in 36% of the patients and more than one

  9. [Treatment choice in dacryostenosis based on single-photon emission computed tomography and X-ray computed tomography findings].

    Science.gov (United States)

    At'kova, E L; Yartsev, V D; Tomashevskiy, I O; Krakhovetskiy, N N

    2016-01-01

    To develop surgical indications in dacryostenosis within the vertical portion of lacrimal pathways that would consider findings of single-photon emission computed tomography (SPECT) combined with X-ray computed tomography (CT). A total of 96 patients with isolated vertical-portion dacryostenosis (127 cases) were enrolled. The examination included collecting Munk's scores for epiphora, optical coherence tomography of the lower tear meniscus, lacrimal scintigraphy, and SPECT/CT. Group 1 (40 cases) was composed of patients with lacrimal obstruction on CT, group 2 (87 cases) - of those whose lacrimal pathways proved passable. There were also 3 patients (4 cases) from group 1, whose lacrimal pathways, despite being blocked on CT, were still passable on SPECT. Surgeries performed in group 1 were endoscopic endonasal dacryocystorhinostomy (DCR) (36 cases) and pathways recanalization with bicanalicular intubation and balloon dacryoplasty (DCP) (4 cases). In group 2, all patients (87 cases) underwent recanalization with bicanalicular intubation (supplemented with balloon DCP in 32 cases). Surgical results were evaluated 8-12 months after the treatment. In group 2, particular attention was paid to the concordance in locations of dacryostenosis provided by CT and SPECT scans. Favorable outcomes of endoscopic endonasal DCR were obtained in as many as 32 cases from group 1 (88.9%), while in 4 cases (12.1%) the condition relapsed. Of those patients whose stenosis was not complete on SPECT, 3 cases (75.0%) improved, 1 (25.0%) - relapsed. In group 2, favorable outcomes were obtained in 65 cases (74.7%), relapses were 22 (25.3%). A high concordance in stenosis locations by CT and SPECT was noted in 60 cases of those who improved (92.3%) and 3 cases of those who relapsed (13.6%). The value of information provided by SPECT/CT has proved high in patients with nasolacrimal duct stenosis or obstruction. A combined scan allows to establish causal relationships between anatomical changes

  10. Detection of hepatic tumor by means of single photon emission computed tomography, gray scale ultrasonography, and x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, Yasuhiro; Jinno, Kenji; Tokuyama, Katsuyuki [Shikoku National Cancer Center Hospital, Matsuyama (Japan)

    1984-07-01

    We have studied the detection of hepatic tumor by single photon emmision computed tomography (SPECT) using rotatory chair and gamma camera. SPECT were taken by multiple section slice not in transaxial but also in frontal and sagital view. The detectability of SPECT turned out to be superior to the conventional liver scintiphoto. By SPECT, minute hepatocellular carcinoma (HCC) of 1.9 cm in diameter was detectable. Simultaneous interpretation of SPECT, US and XCT was more helpful than each independent interpertation. Subject comprised 108 patients with focal hepatic lesions including 48 cases of HCC and 44 cases of metastatic liver tumor. SPECT and celiac angiography on a 63-year-old female with liver cirrhosis revealed hepatic mass lesion in subphrenic region in right hepatic lobe, but XCT or US could not detect any lesion of hepatic tumor. Operated specimen showed confluent-massive type of HCC according to Nakashima's classification with 7 x 7 x 6.5 cm in size, representing replacing proliferation by histological examination. Both sensitivity and false positive rate of detectability of HCC were superior in decreasing order as combined three modalities, US XCT and SPECT. The diagnosis by combined three modalities shows 99% of sensitivity rate with 1% of false negative rate and 0% of false positive rate and 99.5% of accuracy. Differenciation of HCC from metastatic liver cancer or another benign tumor was possible with sensitivity rate of 94.8% and specificity rate of 90.0% by three combined modalities.

  11. The peculiarities of regional volume cerebral blood flow in patients with hypertensive encephalopathy by the findings of single photon emission computed tomography

    International Nuclear Information System (INIS)

    Makejev, S.S.; Novyikova, T.G.; Kustkova, A.S.

    2012-01-01

    The investigation of the state of the brain perfusion in patients with stage II hypertensive encephalopathy (HE) at development of hypertension crisis vs. crisis-free course of HE showed that in 79,5% of the patients with stage II HE, single photon emission computed tomography demonstrated local changes of the blood flow

  12. Benzodiazepine receptor equilibrium constants for flumazenil and midazolam determined in humans with the single photon emission computer tomography tracer [123I]iomazenil

    DEFF Research Database (Denmark)

    Videbaek, C; Friberg, L; Holm, S

    1993-01-01

    twice, once without receptor blockade and once with a constant degree of partial blockade of the benzodiazepine receptors by infusion of nonradioactive flumazenil (Lanexat) or midazolam (Dormicum). Single photon emission computer tomography and blood sampling were performed intermittently for 6 h after...

  13. Assessment of left ventricular function using 201Tl electrocardiogram-gated myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Nishikubo, Naotsugu; Tamai, Hiroyuki

    2013-01-01

    Advances in computed tomography (CT) technology make it possible to obtain left ventricular wall motion using 3D reconstruction. In this study, we compared the images obtained from CT and 201 Tl electrocardiogram (ECG) gated single photon emission computed tomography (SPECT). In 20 patients with ischemic heart disease, we performed 201 Tl ECG gated SPECT (GE Healthcare Millennium VG) and ECG gated CT (Philips Medical Systems Brilliance iCT) to evaluate of left ventricular wall motion during the resting phase. In SPECT, left ventricular images were reconstructed using quantitative gated SPECT (QGS) software. In CT, the images were reconstructed using Virtual Place (AZE Software). The left ventricle was classified into five regions (anterior, lateral, inferior, septal, and apical). The amplitude of the wall motion was classified into five grades according to AHA classification. The values of the wall motion were separately checked by two radiographers. Assessment of left ventricular function myocardial wall movement using the three-dimensional movie display with ECG gated myocardial SPECT data was in agreement with the evaluation by cardiac CT inspection, and corresponded with wall motion in 88 of all 100 segments. SPECT analysis has the same quantity as that of obtained from CT for evaluation of left ventricular wall motion. (author)

  14. Optimization of pinhole single photon emission computed tomography (pinhole SPECT) reconstruction

    International Nuclear Information System (INIS)

    Israel-Jost, V.

    2006-11-01

    In SPECT small animal imaging, it is highly recommended to accurately model the response of the detector in order to improve the low spatial resolution. The volume to reconstruct is thus obtained both by back-projecting and de-convolving the projections. We chose iterative methods, which permit one to solve the inverse problem independently from the model's complexity. We describe in this work a Gaussian model of point spread function (PSF) whose position, width and maximum are computed according to physical and geometrical parameters. Then we use the rotation symmetry to replace the computation of P projection operators, each one corresponding to one position of the detector around the object, by the computation of only one of them. This is achieved by choosing an appropriate polar discretization, for which we control the angular density of voxels to avoid over-sampling the center of the field of view. Finally, we propose a new family of algorithms, the so-called frequency adapted algorithms, which enable to optimize the reconstruction of a given band in the frequency domain on both the speed of convergence and the quality of the image. (author)

  15. Breast cancer staqging using technitium-99m sestamibi and indium-111 pentetreotide single-photon emission tomography

    International Nuclear Information System (INIS)

    Chiti, A.; Agresti, R.; Maffioli, L.S.; Tomasic, G.; Savelli, G.; Crippa, F.; Pilotti, S.; Greco, M.; Bombardieri, E.

    1997-01-01

    We evaluated the clinical usefulness of single-photon emission tomography (SPET) with technetium-99m sestamibi and indium-111 pentetrotide in breast cancer staging. Fifteen patients with clinical and/or mammographic findings suggesting Tl-2N0-l breast cancer were studied. SPET images were acquired 20 min after 99m Tc-sestamibi injection and 4 and 24 h after 111 In-pentetreotide injection. Patients underwent surgery the day after the later 111 In-pentetrotide acquisition. Pathological examination showed 16 tumours in the 15 patients, with one bilateral carcinoma. The mean tumour diamter was 18.7 mm. Metastatic axillary involment was found in 6/16 tumours, with a mean of five metastatic nodes per axillary node involment. Both tracers correctly identified 15/16 primary tumours and five of the six cases of metastatic axillary node involvement. No difference between the tracers was observed in breast cancer staging. 99m Tc-sestamibi seems to the better tracer in terms of physical characteristics, execution time and cost-effectivness. Our data suggest the future possibility of using nuclear medicine imaging to avoid axillary dissection in patiens with Tl breast cancer

  16. Evaluation of suspected malignant pulmonary lesions with 201Tl single photon emission computed tomography

    International Nuclear Information System (INIS)

    Tonami, N.; Yokoyama, K.; Shuke, N.

    1993-01-01

    201 Tl single photo emission computed tomography (SPECT) was evaluated in 170 patients suspected of having a malignant pulmonary lesion greater than 20 mm in diameter on the surgical specimen. Delayed SPECT visualized all of the 147 malignant pulmonary lesions and 16 of the 23 benign pulmonary lesions, and generally exhibited the lesion more clearly than the early SPECT images. There was no significant difference in delayed ratio (uptake ratio of the lesion to the normal lung on delayed scan) among the various histological groups except between the adenocarcinoma and large cell carcinoma groups, and no difference was noted between the malignant and benign lesions. However, in retention index (degree of retention in the lesion) a significant difference was noted between the malignant and benign lesions, although there was no significant difference in this index among malignant different histology groups. These results indicate that this method is useful for visualizing malignant pulmonary lesions greater than 20 mm in diameter to exclude the possibility of malignancy in the lesions when no abnormal 201 Tl accumulation is observed. When the lesion shows abnormal 201 Tl accumulation, the retention index seems to help differentiate malignant from benign lesions. (author)

  17. Stress scintigraphy using single-photon emission computed tomography in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Nohara, R.; Kambara, H.; Suzuki, Y.; Tamaki, S.; Kadota, K.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Twenty-seven patients with angina pectoris, 24 with postmyocardial infarction angina and 7 with normal coronary arteries were examined by exercise thallium-201 emission computed tomography (SPECT) and planar scintigraphy. Exercise SPECT was compared with the reperfusion imaging obtained approximately 2 to 3 hours after exercise. The sensitivity and specificity of demonstrating involved coronary arteries by identifying the locations of myocardial perfusion defects were 96 and 87% for right coronary artery, 88 and 89% for left anterior descending artery (LAD) and 78 and 100% for left circumflex artery (LC). These figures are higher than those for planar scintigraphy (85 and 87% for right coronary artery, 73 and 89% for LAD and 39 and 100% for LC arteries). In patients with 3-vessel disease, sensitivity of SPECT (100, 88 and 75% for right coronary artery, LAD and LC, respectively) was higher than planar imaging (88, 63 and 31%, respectively), with a significant difference for LC (p less than 0.05). In 1, 2 and 0-vessel disease the sensitivity and specificity of the 2 techniques were comparable. Multivessel disease was more easily identified as multiple coronary involvement than planar imaging with a significant difference in 3-vessel disease (p less than 0.05). In conclusion, stress SPECT provides useful information for the identification of LC lesions in coronary heart disease, including 3-vessel involvement

  18. Diagnostic accuracy of exercise thallium-201 single-photon emission computed tomography in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Larcos, G.; Gibbons, R.J.; Brown, M.L.

    1991-01-01

    Recent reports have proposed that abnormal apical or anterior wall perfusion with exercise thallium-201 imaging may increase diagnostic accuracy for disease of the left anterior descending artery in patients with left bundle branch block (LBBB). To evaluate these suggestions, 83 patients with LBBB who underwent thallium-201 single-photon emission computed tomography and coronary angiography within an interval of 3 months were retrospectively reviewed. There were 59 men and 24 women aged 33 to 84 years (mean 65). Myocardial perfusion to the apex, anterior wall and anterior septum were scored qualitatively by consensus of 2 experienced observers and by quantitative analysis in comparison with a normal data base. The sensitivity, specificity and accuracy of perfusion defects in these segments were then expressed according to angiographic findings. Significant stenosis of vessels within the left anterior descending artery territory was present in 38 patients. By receiver-operator characteristic analysis, a fixed or reversible defect within the apex by the qualitative method was the best criterion for coronary artery disease. However, although highly sensitive (79 and 85% by the qualitative and quantitative methods, respectively), an apical defect was neither specific (38 and 16%, respectively), nor accurate (57 and 46%, respectively). Perfusion abnormalities in the anterior wall and septum were also of limited diagnostic accuracy. Thus, modified interpretative criteria in patients with LBBB are not clinically useful in the assessment of left anterior descending artery disease

  19. Quantitative myocardial thallium single-photon emission computed tomography in normal women: demonstration of age-related differences

    International Nuclear Information System (INIS)

    Cohen, M.; Touzery, C.; Cottin, Y.; Benoit, T.; Athis, P. d'; Roy, S.; Louis, P.; Wolf, J.E.; Rigo, P.; Brunotte, F.

    1996-01-01

    The aim of this study is the development of a database of normal women for quantitative analysis of exercise and reinjection myocardial single-photon emission computed tomography (SPET). We studied 101 subjects (40 males and 61 females) with less than 5% likelihood of coronary artery disease. All patients underwent stress and rest thallium-201 myocardial SPET. Myocardial stress was induced by bicycle exercise test (n=51), dipyridamole infusion (n=27) or a combined test (n=23). Multivariate ANOVA showed that the type of stress did not influence the percentage of thallium uptake for each region. Significant differences between men and women were found for the percentage of uptake in the inferior and the anterior wall. The most original finding of this study is the correlation between age and thallium uptake in the three regions of the anterior wall, showing an increase in measured thallium uptake with age for women. Consequently, two groups of women, those under and those over 55 years old, were separated, with a significantly lower tracer uptake in the anterior wall in the younger age group. (orig./MG)

  20. A single photon emission computed tomograph based on a limited dumber of detectors for fluid flow visualization

    International Nuclear Information System (INIS)

    Legoupil, S.

    1999-01-01

    We present in this work a method for fluid flow visualization in a system using radioactive tracers. The method is based on single photon emission computed tomography techniques, applied to a limited number of discrete detectors. We propose in this work a method for the estimation of the transport matrix of photons, associated to the acquisition system. This method is based on the modelization of profiles acquired for a set of point sources located in the imaged volume. Monte Carlo simulations allow to separate scattered photons from those directly collected by the system. The influence of the energy tracer is exposed. The reconstruction method is based on the maximum likelihood - expectation maximization algorithm. An experimental device, based on 36 detectors was realised for the visualization of water circulation in a vessel. A video monitoring allows to visualize the dye water tracer. Dye and radioactive tracers are injected simultaneously in a water flow circulating in the vessel. Reconstructed and video images are compared. Quantitative and qualitative analysis show that fluid flow visualization is feasible with a limited number of detectors. This method can be applied for system involving circulations of fluids. (author)

  1. Real-time axial motion detection and correction for single photon emission computed tomography using a linear prediction filter

    International Nuclear Information System (INIS)

    Saba, V.; Setayeshi, S.; Ghannadi-Maragheh, M.

    2011-01-01

    We have developed an algorithm for real-time detection and complete correction of the patient motion effects during single photon emission computed tomography. The algorithm is based on a linear prediction filter (LPC). The new prediction of projection data algorithm (PPDA) detects most motions-such as those of the head, legs, and hands-using comparison of the predicted and measured frame data. When the data acquisition for a specific frame is completed, the accuracy of the acquired data is evaluated by the PPDA. If patient motion is detected, the scanning procedure is stopped. After the patient rests in his or her true position, data acquisition is repeated only for the corrupted frame and the scanning procedure is continued. Various experimental data were used to validate the motion detection algorithm; on the whole, the proposed method was tested with approximately 100 test cases. The PPDA shows promising results. Using the PPDA enables us to prevent the scanner from collecting disturbed data during the scan and replaces them with motion-free data by real-time rescanning for the corrupted frames. As a result, the effects of patient motion is corrected in real time. (author)

  2. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    International Nuclear Information System (INIS)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo; Sakata, Hitomi; Ishihara, Tadayuki

    2001-01-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ( 201 Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting 201 Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by 201 Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting 201 Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  3. Abnormal response to mental stress in patients with Takotsubo cardiomyopathy detected by gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Sciagra, Roberto; Genovese, Sabrina; Pupi, Alberto; Parodi, Guido; Bellandi, Benedetta; Antoniucci, David; Del Pace, Stefano; Zampini, Linda; Gensini, Gian Franco

    2010-01-01

    Persistent abnormalities are usually not detected in patients with Takotsubo cardiomyopathy (TTC). Since sympathetically mediated myocardial damage has been proposed as a causative mechanism of TTC, we explored whether mental stress could evoke abnormalities in these patients. One month after an acute event, 22 patients fulfilling all TTC diagnostic criteria and 11 controls underwent resting and mental stress gated single photon emission computed tomography (SPECT). Perfusion, wall motion, transient ischaemic dilation (TID) and left ventricular (LV) ejection fraction (EF) were evaluated. None of the controls showed stress-induced abnormalities. Mental stress evoked regional changes (perfusion defects and/or wall motion abnormality) in 16 TTC subjects and global abnormalities (LVEF fall >5% and/or TID >1.10) in 13; 3 had a completely negative response. TID, delta LVEF and delta wall motion score were significantly different in TTC vs control patients: 1.08 ± 0.20 vs 0.95 ± 0.11 (p < 0.05), -1.7 ± 6% vs 4 ± 5% (p < 0.02) and 2.5 (0, 4.25) vs 0 (0, 0) (p < 0.002), respectively. Mental stress may evoke regional and/or global abnormalities in most TTC patients. The abnormal response to mental stress supports the role of sympathetic stimulation in TTC. Mental stress could thus be helpful for TTC evaluation. (orig.)

  4. The clinical meaning of gastric-wall hyperactivity observed on sestamibi cardiac single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cote, C.; Dumont, M. [Centre Hospitalier Universitaire de Quebec, Dept. of Nuclear Medicine, Quebec, Quebec (Canada)]. E-mail: christian.cote@chuq.qc.ca

    2004-06-01

    To evaluate prospectively the incidence and clinical meaning, if any, of gastric-wall hyperactivity observed on sestamibi cardiac single-photon emission computed tomography (SPECT). This phenomenon is completely different from the well-known intraluminal gastric reflux of sestamibi. A group of 819 patients who underwent sestamibi cardiac SPECT was studied from January 2000 to October 2000. Gastric-wall activity was graded qualitatively. Only patients with gastric-wall activity near or equivalent to their heart activity were considered for subsequent analysis. The medical records of patient candidates were reviewed, and their family physicians were asked to respond to a questionnaire by telephone when further information was needed. We identified 13 patients with significant gastric-wall hyperactivity, which was more intense on rest images. Our review of the clinical data shows that all these patients were suffering from dyspepsia and were taking gastric medication. These 13 cases were assigned to 3 groups: gastroesophageal reflux, chronic functional dyspepsia and nonspecific gastritis. Significant gastric-wall hyperactivity is an infrequent observation on sestamibi cardiac SPECT. Our results indicate that the presence of significant gastric-wall hyperactivity is associated with dyspepsia. It is important to realize that this gastric-wall hyperactivity by its proximity to the inferior myocardial wall could in some circumstances lead to either false-negative or false-positive findings, representing a diagnostic problem. Although infrequent, this situation could be avoided by proper quality control, including a systematic review of the raw cine data before reading the images. (author)

  5. Clinical characteristics in patients showing ischemic electrocardiographic changes during adenosine triphosphate loading single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Ohtaki, Yuka; Chikamori, Taishiro; Hida, Satoshi; Tanaka, Hirokazu; Igarashi, Yuko; Hatano, Tsuguhisa; Usui, Yasuhiro; Miyagi, Manabu; Yamashina, Akira

    2010-01-01

    Although ischemic electrocardiographic (ECG) changes during dipyridamole or adenosine infusion have been reported as a marker for severe coronary artery disease (CAD), few studies have focused on ST-segment changes with adenosine triphosphate (ATP)-loading myocardial single-photon emission computed tomography (SPECT). Between January 2003 and August 2008, 4650 consecutive patients underwent ATP-loading SPECT. After 1412 patients with left bundle branch block, pacemaker rhythm, or previous coronary revascularization were excluded, 16 out of 3238 patients (0.5%) showed ischemic ST-segment depression during ATP-loading myocardial SPECT. They were aged 67±11 years; 10 were men and 6 women. Of these patients, 8 demonstrated perfusion abnormalities, whereas the remaining 8 showed normal myocardial perfusion imaging. In 6 of the 8 patients with abnormal SPECT, coronary angiography was performed, revealing left main trunk disease in 1 patient, 3-vessel disease in 4, 1-vessel disease with proximal left ascending artery occlusion in 1, and an insignificant lesion in 1. By contrast, no major cardiac event was observed in the 8 patients with normal SPECT during follow-up for an average of 2 years. The prevalence of ischemic ST-segment changes during ATP loading is very rare. However, this finding should be taken into account since almost half of the patients, particularly those with perfusion abnormalities, may have severe CAD which requires coronary revascularization. (author)

  6. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  7. Single photon emission computed tomography with N-isopropyl-p-[123I] iodoamphetamine in dementia of the Alzheimer type

    International Nuclear Information System (INIS)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki; Yasui, Shinichi; Yuasa, Satoru; Shimizu, Akinori; Kurachi, Masayoshi; Seki, Hiroyasu; Fukuta, Tsutomu.

    1989-01-01

    Correlation between brain uptake of N-isopropyl-p-[I-123]iodoamphetamine (I-123 IMP), as shown on single photon emission computed tomography (SPECT) scans, and clinical stages was examined in 8 patients with Alzheimer type dementia. The patients were clinically staged as Stage I (3), Stage II (3), or Stage III (2). The count ratio of each cerebral lobe to the cerebellum was calculated on horizontal SPECT scans. Stage I patients had a decreased I-123 IMP uptake in the temporal and parietal lobes. The decreased uptake in these areas became marked in Stage II patients, with diffusely slight uptake of I-123 IMP in the brain. In Stage III patients, the uptake of I-123 IMP was markedly decreased in the whole brain, including temporal, parietal, and frontal lobes. For five patients of Stage II and III, bilateral differences in the cerebral hemispheres were observed, corresponding to neurologic symptoms. Iodine-123 IMP SPECT was thus considered useful in clinically evaluating Alzheimer type dementia and in determining degenerative process of this disease. (Namekawa, K)

  8. Single photon emission computed tomography before and after treatment of anxiety using a selective serotonin reuptake inhibitor

    International Nuclear Information System (INIS)

    Warwick, J.M.; Heerden, B.B. van; Stein, D.J.; Niehaus, D.J.H.; Seedat, S.; Linden, G. van der; Harvey, B.A.

    2002-01-01

    Background: The selective serotonin reuptake inhibitors (SSRIs) are currently recommended as first line medications for a number of different anxiety disorders, including obsessive-compulsive disorder (OCD), posttraumatic stress disorder (PTSD), and social anxiety disorder (social phobia) (SAD). This raises the question of what effects these agents have on the functional neuroanatomy of anxiety disorders. Methods: Single photon emission computed tomography (SPECT) brain scanning was undertaken in patients with OCD, PTSD, and SAD before and after treatment with citalopram, the most selective of the SSRIs. Statistical parametric mapping (SPM) was used to compare scans (pre- vs post-medication, and responders vs nonresponders) in the combined group of subjects. Results: Citalopram pharmacotherapy resulted in significant deactivation within anterior and superior cingulate and left hippocampus. Deactivation within the anterior cingulate, left paracingular cortex, and right inferior frontal cortex was more marked in treatment responders. Baseline activation did not, however, predict response to pharmacotherapy. Conclusion: Although each of the anxiety disorders may be mediated by different neurocircuits, there are some overlaps in the functional neuroanatomy of their response to SSRI treatment. The current data is consistent with previous work demonstrating the importance of limbic circuits in this spectrum of disorders. These play a crucial role in cognitive-affective processing, and are innervated by serotonergic neurons

  9. Intellectual function and radiological images in patients with amyotrophic lateral sclerosis. Special reference to single photon emission computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Hiroo; Kanda, Mikio; Fukui, Toshiya; Sugita, Koujiro [Showa Univ., Tokyo (Japan). School of Medicine

    1994-10-01

    To clarify cognitive decline in amyotrophic lateral sclerosis (ALS), we compared cognitive and motor signs with neuroradiological features, with special reference to single photon emission computed tomography (SPECT), in 23 patients with ALS. Of these 23 patients, five demented patients (ALS-D) showed a decrease in voluntary speech output, abnormal behavior or character change. SPECT images in these patients were specifically characterized by marked uptake reduction in the frontal lobes. ALS patients with normal mentality (ALS-N) showed either a normal pattern or non-specific patchy uptake reduction on SPECT, but never showed the diffuse frontal uptake reduction that was observed in ALS-D patients. None of the ALS-N patients showed cognitive decline or frontal uptake reduction during the follow-up period of up to 29 months. There was no relation in either ALS-D or ALS-N patients between the degree of tracer uptake reduction and clinical features of ALS including severity and duration of illness. Clinical and neuroradiological features in ALS-D patients were compatible with those of `frontal lobe dementia`. ALS-D patients may compose a distinct group because cognitive decline is unlikely to occur in ALS-N patients with a long clinical course. ALS-D patients may be differentiated from other non-demented ALS patients in the early clinical course by the characteristic diffuse frontal uptake reduction on SPECT. (author).

  10. Intellectual function and radiological images in patients with amyotrophic lateral sclerosis. Special reference to single photon emission computed tomography images

    International Nuclear Information System (INIS)

    Ichikawa, Hiroo; Kanda, Mikio; Fukui, Toshiya; Sugita, Koujiro

    1994-01-01

    To clarify cognitive decline in amyotrophic lateral sclerosis (ALS), we compared cognitive and motor signs with neuroradiological features, with special reference to single photon emission computed tomography (SPECT), in 23 patients with ALS. Of these 23 patients, five demented patients (ALS-D) showed a decrease in voluntary speech output, abnormal behavior or character change. SPECT images in these patients were specifically characterized by marked uptake reduction in the frontal lobes. ALS patients with normal mentality (ALS-N) showed either a normal pattern or non-specific patchy uptake reduction on SPECT, but never showed the diffuse frontal uptake reduction that was observed in ALS-D patients. None of the ALS-N patients showed cognitive decline or frontal uptake reduction during the follow-up period of up to 29 months. There was no relation in either ALS-D or ALS-N patients between the degree of tracer uptake reduction and clinical features of ALS including severity and duration of illness. Clinical and neuroradiological features in ALS-D patients were compatible with those of 'frontal lobe dementia'. ALS-D patients may compose a distinct group because cognitive decline is unlikely to occur in ALS-N patients with a long clinical course. ALS-D patients may be differentiated from other non-demented ALS patients in the early clinical course by the characteristic diffuse frontal uptake reduction on SPECT. (author)

  11. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  12. Single photon emission computed tomography and statistical parametric mapping analysis in cirrhotic patients with and without minimal hepatic encephalopathy

    International Nuclear Information System (INIS)

    Nakagawa, Yuri; Matsumura, Kaname; Iwasa, Motoh; Kaito, Masahiko; Adachi, Yukihiko; Takeda, Kan

    2004-01-01

    The early diagnosis and treatment of cognitive impairment in cirrhotic patients is needed to improve the patients' daily living. In this study, alterations of regional cerebral blood flow (rCBF) were evaluated in cirrhotic patients using statistical parametric mapping (SPM). The relationships between rCBF and neuropsychological test, severity of disease and biochemical data were also assessed. 99m Tc-ethyl cysteinate dimer single photon emission computed tomography was performed in 20 patients with non-alcoholic liver cirrhosis without overt hepatic encephalopathy (HE) and in 20 age-matched healthy subjects. Neuropsychological tests were performed in 16 patients; of these 7 had minimal HE. Regional CBF images were also analyzed in these groups using SPM. On SPM analysis, cirrhotic patients showed regions of significant hypoperfusion in the superior and middle frontal gyri, and inferior parietal lobules compared with the control group. These areas included parts of the premotor and parietal associated areas of the cortex. Among the cirrhotic patients, those with minimal HE had regions of significant hypoperfusion in the cingulate gyri bilaterally as compared with those without minimal HE. Abnormal function in the above regions may account for the relatively selective neuropsychological deficits in the cognitive status of patients with cirrhosis. These findings may be important in the identification and management of cirrhotic patients with minimal HE. (author)

  13. Dual-isotope single-photon emission computed tomography for dopamine and serotonin transporters in normal and parkinsonian monkey brains

    International Nuclear Information System (INIS)

    Li, I-H.; Huang, W.-S.; Yeh, C.-B.; Liao, M.-H.; Chen, C.-C.; Shen, L.-H.; Liu, J.-C.; Ma, K.-H.

    2009-01-01

    Introduction: Parkinson's disease (PD) affects both dopaminergic and serotonergic systems. In this study, we simultaneously evaluated dopamine and serotonin transporters in primates using dual-isotope single-photon emission computed tomography (SPECT) imaging and compared the results with traditional single-isotope imaging. Methods: Four healthy and one 6-OHDA-induced PD monkeys were used for this study. SPECT was performed over 4 h after individual or simultaneous injection of [ 99m Tc]TRODAT-1 (a dopamine transporter imaging agent) and [ 123 I]ADAM (a serotonin transporter imaging agent). Results: The results showed that the image quality and uptake ratios in different brain regions were comparable between single- and dual-isotope studies. The striatal [ 99m Tc]TRODAT-1 uptake in the PD monkey was markedly lower than that in normal monkeys. The uptake of [ 123 I]ADAM in the midbrain of the PD monkey was comparable to that in the normal monkeys, but there were decreased uptakes in the thalamus and striatum of the PD monkey. Conclusions: Our results suggest that dual-isotope SPECT using [ 99m Tc]TRODAT-1 and [ 123 I]ADAM can simultaneously evaluate changes in dopaminergic and serotonergic systems in a PD model.

  14. Dual-isotope single-photon emission computed tomography for dopamine and serotonin transporters in normal and parkinsonian monkey brains

    Energy Technology Data Exchange (ETDEWEB)

    Li, I-H. [Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei 114, Taiwan (China); Huang, W.-S. [Department of Nuclear Medicine, Tri-Service General Hospital, Taipei, 114, Taiwan (China); Yeh, C.-B. [Department of Psychiatry, Tri-Service General Hospital, Taipei, 114, Taiwan (China); Liao, M.-H.; Chen, C.-C.; Shen, L.-H. [Division of Isotope Application, Institute of Nuclear Energy Research, Taoyaun, 325 Taiwan (China); Liu, J.-C. [Department of Biology and Anatomy, National Defense Medical Center, Taipei 114, Taiwan (China); Ma, K.-H. [Department of Biology and Anatomy, National Defense Medical Center, Taipei 114, Taiwan (China)], E-mail: kuohsing91@yahoo.com.tw

    2009-08-15

    Introduction: Parkinson's disease (PD) affects both dopaminergic and serotonergic systems. In this study, we simultaneously evaluated dopamine and serotonin transporters in primates using dual-isotope single-photon emission computed tomography (SPECT) imaging and compared the results with traditional single-isotope imaging. Methods: Four healthy and one 6-OHDA-induced PD monkeys were used for this study. SPECT was performed over 4 h after individual or simultaneous injection of [{sup 99m}Tc]TRODAT-1 (a dopamine transporter imaging agent) and [{sup 123}I]ADAM (a serotonin transporter imaging agent). Results: The results showed that the image quality and uptake ratios in different brain regions were comparable between single- and dual-isotope studies. The striatal [{sup 99m}Tc]TRODAT-1 uptake in the PD monkey was markedly lower than that in normal monkeys. The uptake of [{sup 123}I]ADAM in the midbrain of the PD monkey was comparable to that in the normal monkeys, but there were decreased uptakes in the thalamus and striatum of the PD monkey. Conclusions: Our results suggest that dual-isotope SPECT using [{sup 99m}Tc]TRODAT-1 and [{sup 123}I]ADAM can simultaneously evaluate changes in dopaminergic and serotonergic systems in a PD model.

  15. Dementia due to normal-pressure hydrocephalus by single photon emission computer tomography

    International Nuclear Information System (INIS)

    Borbely, K.; Kordas, M.; Kadar, K.; Nyary, I.

    2002-01-01

    Aims: Once a diagnosis of dementia is established, the irreversible and degenerative types of dementia should be differentiated from those with potentially treatable causes. Normal-pressure hydrocephalus (NPH) is a reversible and poorly understood cause of mental impairment. Ventricular enlargement as registered by Computer Tomography (CT) or Magnetic Resonance Imaging (MRI) might be neurologically stable or progressive in nature. CT/MRI can display the exact size and shape of the ventricles. However, either CT or MRI cerebrospinal fluid (CSF) flow studies are unable to predict the response to shunt operation. The purpose of this study was to determine the role of 99m Tc-HMPAO regional cerebral blood flow (rCBF) SPECT combined with 99m Tc-DTPA CSF-SPECT in the preoperative evaluation of patients with chronic hydrocephalus. Methods: 103 consecutive studies were carried out where patient management was of concern with a standard technique for each patient (555 MBq 99mTc-HMPAO/ECD; 250 MBq 99mTc-DTPA, 1/3/6/24 h planar, 6/24h SPECT; double head ADAC SPECT camera). RCBF SPECT studies were analysed visually and by a special region of interests (ROIs) program. Circular ROIs were placed over the striatum, thalamus, white matter, frontal, temporal, parietal, occipital cortex, and cerebellum. ROIs were normalized to the whole brain average. The statistical analysis was considered significant at P≤0.05. The results of combined SPECT studies were correlated with CT/MRI, and clinical findings. Results: In 75 cases the hydrocephalus appeared to be communicating. In 19 cases there was a contradiction between the results of CT/MRI and CSF SPECT. 67 ventriculoperitoneal shunt implantations were carried out on the basis of combined SPECT studies. In 67 patients the rCBF SPECT except for hydrocephalus, demonstrated decreased rCBF in the periventricular white matter, thalamus and basal ganglia. There were additional bilateral rCBF abnormalities in the frontal or fronto

  16. Superconducting Single Photon Detectors

    NARCIS (Netherlands)

    Dorenbos, S.N.

    2011-01-01

    This thesis is about the development of a detector for single photons, particles of light. New techniques are being developed that require high performance single photon detection, such as quantum cryptography, single molecule detection, optical radar, ballistic imaging, circuit testing and

  17. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  18. Regional cerebral blood flow in patients with sickle cell disease: study with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Al-Kandari, F.A.; Owunwanne, A.; Syed, G.M.; Elgazzar, A.H.; Rizui, A.M.; Al-Ajmi, J.A.; Mohammed, A.M.; Ar Marouf, R.; Shiekh, M.

    2007-01-01

    Neurological complications have been reported in patients with sickle-cell disease (SCD) using positron emission tomography (PET), magnetic resonance imaging (MRI), and computed tomography (CT), but not with single photon emission computed tomography (SPECT). The objective of this study was to investigate brain perfusion in the patients with SCD using SPECT after technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO), was administered and compare the findings with those of demography, physical examination, MRI and hematological profile. The study involved 21 patients (12 males, 9 females, age at study 8-45 years) who were known to be having SCD for a duration of at least 5 years. The patients were not in acute crisis and had normal neurological assessments with no known history of stroke or transient ischemic episode or previous abnormal CT or MRI brain scan, and were right-handed. The brain SPECT was performed after intravenous injection of 740 MBq (20 mCi) 99m Tc-HMPAO in adults or an appropriate dose in pediatric patients. The scans were visually interpreted by two nuclear medicine physicians and a decision was reached by consensus. An MRI done 3 months later was interpreted by a radiologist. The demographic data and hematological profile were obtained from the medical records of the patients. Of the 21 patients, 7 (age 11-22 years) had brain perfusion deficit mostly in the frontal lobe either alone or in combination with temporal and/or parietal lobe. The MRI was abnormal in 2 patients. The brain perfusion deficit was not associated with the demographic data of the patients or hematological profiles. The findings show that SPECT was useful in detecting brain perfusion deficit in SCD patients, and such an early detection may be clinically useful in the subsequent follow-up of such patients, since it is known that cerebral perfusion deficit can lead to silent infarct and/or overt stroke, and affect cognitive skills. (author)

  19. Correlative single photon emission computed tomography imaging of [123I]altropane binding in the rat model of Parkinson's

    International Nuclear Information System (INIS)

    Gleave, Jacqueline A.; Farncombe, Troy H.; Saab, Chantal; Doering, Laurie C.

    2011-01-01

    Introduction: This study used the dopamine transporter (DAT) probe, [ 123 I]-2β-carbomethoxy-3β-(4-fluorophenyl)-N-(3-iodo-E-allyl)nortropane ([ 123 I]altropane), to assess the DAT levels in the 6-hydroxydopamine rat model of Parkinson's disease. We sought to assess if the right to left [ 123 I]altropane striatal ratios correlated with dopamine content in the striatum and substantia nigra and with behavioural outcomes. Methods: [ 123 I]altropane images taken pre- and postlesion were acquired before and after the transplantation of neural stem/progenitor cells. The images obtained using [ 123 I]altropane and single photon emission computed tomography (SPECT) were compared with specific behavioural tests and the dopamine content assessed by high-performance liquid chromatography. Results: [ 123 I]altropane binding correlated with the content of dopamine in the striatum; however, [ 123 I]altropane binding did not correlate with the dopamine content in the substantia nigra. There was a significant correlation of altropane ratios with the cylinder test and the postural instability test, but not with amphetamine rotations. The low coefficient of determination (r 2 ) for these correlations indicated that [ 123 I]altropane SPECT was not a good predictor of behavioural outcomes. Conclusion: Our data reveal that [ 123 I]altropane predicts the integrity of the striatal dopamine nerve terminals, but does not predict the integrity of the nigrostriatal system. [ 123 I]altropane could be a useful marker to measure dopamine content in cell replacement therapies; however, it would not be able to evaluate outcomes for neuroprotective strategies.

  20. Measurement of cerebral blood flow by single photon emission computed tomography in cases of internal carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Sunada, Ichiro [Osaka City Univ. (Japan). Faculty of Medicine

    1989-06-01

    Cerebral blood flow (CBF) was measured with {sup 133}xenon inhalation and single photon emission computed tomography in 33 cases of internal carotid artery occlusion, in the resting state and 25 minutes after acetazolamide administration. The patient population consisted of 24 males and nine females with a mean age of 57 years, who presented with transient ischemic attacks or stroke. Acetazolamide inhibits carbonic anhydrase, and CBF increases as a result of dilatation of cerebral arteries due to CO{sub 2} accumulation. The mean CBF was 46 ml/100 g/min on the affected hemisphere and 56 ml/100 g/min on the unaffected hemisphere. The mean CBF value obtained by the same method in 10 normal volunteers was 55 ml/100 g/min. The average increase in CBF after acetazolamide administration was 9% on the affected side and 17% on the unaffected side. The average increase in 10 normal volunteers was 32%. The reduced cerebral arterial reactivity to acetazolamide administration was bilateral in the patient group, suggesting that the cerebral arteries were dilated so as to maintain normal CBF. Extra-intracranial (EC-IC) bypass surgery was performed in nine patients. Preoperatively, the mean CBF was 48 ml/100 g/min on the affected side and 57 ml/100 g/min on the unaffected side. With postoperative acetazolamide administration, the percent increase in CBF rose from 13% to 22% on the affected side and from 17% to 23% on the unaffected side. The bilateral change toward normal in cerebral arterial reactivity to acetazolamide indicates that the dilated cerebral arteries returned to normal after EC-IC bypass surgery. This suggests that bypass surgery is effective in patients with internal carotid artery occlusion in whom ischemia is caused only by hemodynamic factors, and that measurement of CBF via acetazolamide loading is useful in identifying appropriate candidates for bypass surgery.

  1. I-123 iomazenil single photon emission computed tomography for detecting loss of neuronal integrity in patients with traumatic brain injury.

    Science.gov (United States)

    Abiko, Kagari; Ikoma, Katsunori; Shiga, Tohru; Katoh, Chietsugu; Hirata, Kenji; Kuge, Yuji; Kobayashi, Kentaro; Tamaki, Nagara

    2017-12-01

    Traumatic brain injury (TBI) causes brain dysfunction in many patients. Using C-11 flumazenil (FMZ) positron emission tomography (PET), we have detected and reported the loss of neuronal integrity, leading to brain dysfunction in TBI patients. Similarly to FMZ PET, I-123 iomazenil (IMZ) single photon emission computed tomography (SPECT) is widely used to determine the distribution of the benzodiazepine receptor (BZR) in the brain cortex. The purpose of this study is to examine whether IMZ SPECT is as useful as FMZ PET for evaluating the loss of neuronal integrity in TBI patients. The subjects of this study were seven patients who suffered from neurobehavioral disability. They underwent IMZ SPECT and FMZ PET. Nondisplaceable binding potential (BP ND ) was calculated from FMZ PET images. The uptake of IMZ was evaluated on the basis of lesion-to-pons ratio (LPR). The locations of low uptake levels were visually evaluated both in IMZ SPECT and FMZ PET images. We compared FMZ BP ND and (LPR-1) of IMZ SPECT. In the visual assessment, FMZ BP ND decreased in 11 regions. In IMZ SPECT, low uptake levels were observed in eight of the 11 regions. The rate of concordance between FMZ PET and IMZ SPECT was 72.7%. The mean values IMZ (LPR-1) (1.95 ± 1.01) was significantly lower than that of FMZ BP ND (2.95 ± 0.80 mL/mL). There was good correlation between FMZ BP ND and IMZ (LPR-1) (r = 0.80). IMZ SPECT findings were almost the same as FMZ PET findings in TBI patients. The results indicated that IMZ SPECT is useful for evaluating the loss of neuronal integrity. Because IMZ SPECT can be performed in various facilities, IMZ SPECT may become widely adopted for evaluating the loss of neuronal integrity.

  2. Differences in cerebral perfusion deficits in mild traumatic brain injury and depression using single-photon emission computed tomography.

    Science.gov (United States)

    Romero, Kristoffer; Black, Sandra E; Feinstein, Anthony

    2014-01-01

    Numerous studies have shown decreased perfusion in the prefrontal cortex following mild traumatic brain injury (mTBI). However, similar hypoperfusion can also be observed in depression. Given the high prevalence of depressive symptoms following mTBI, it is unclear to what extent depression influences hypoperfusion in TBI. Mild TBI patients without depressive symptoms (mTBI-noD, n = 39), TBI patients with depressive symptoms (mTBI-D, n = 13), and 15 patients with major depressive disorder (MDD), but no TBI were given 99m T-ECD single-photon emission computed tomography (SPECT) scans within 2 weeks of injury. All subjects completed tests of information processing speed, complex attention, and executive functioning, and a self-report questionnaire measuring symptoms of psychological distress. Between-group comparisons of quantified SPECT perfusion were undertaken using univariate and multivariate (partial least squares) analyses. mTBI-D and mTBI-noD groups did not differ in terms of cerebral perfusion. However, patients with MDD showed hypoperfusion compared to both TBI groups in several frontal (orbitofrontal, middle frontal, and superior frontal cortex), superior temporal, and posterior cingulate regions. The mTBI-D group showed poorer performance on a measure of complex attention and working memory compared to both the mTBI-noD and MDD groups. These results suggest that depressive symptoms do not affect SPECT perfusion in the sub-acute phase following a mild TBI. Conversely, MDD is associated with hypoperfusion primarily in frontal regions.

  3. Measurement of acute Q-wave myocardial infarct size with single photon emission computed tomography imaging of indium-111 antimyosin.

    Science.gov (United States)

    Antunes, M L; Seldin, D W; Wall, R M; Johnson, L L

    1989-04-01

    Myocardial infarct size was measured by single photon emission computed tomography (SPECT) following injection of indium-111 antimyosin in 27 patients (18 male and 9 female; mean age 57.4 +/- 10.5 years, range 37 to 75) who had acute transmural myocardial infarction (MI). These 27 patients represent 27 of 35 (77%) consecutive patients with acute Q-wave infarctions who were injected with indium-111 antimyosin. In the remaining 8 patients either tracer uptake was too faint or the scans were technically inadequate to permit infarct sizing from SPECT reconstructions. In the 27 patients studied, infarct location by electrocardiogram was anterior in 15 and inferoposterior in 12. Nine patients had a history of prior infarction. Each patient received 2 mCi of indium-111 antimyosin followed by SPECT imaging 48 hours later. Infarct mass was determined from coronal slices using a threshold value obtained from a human torso/cardiac phantom. Infarct size ranged from 11 to 87 g mean 48.5 +/- 24). Anterior infarcts were significantly (p less than 0.01) larger (60 +/- 20 g) than inferoposterior infarcts (34 +/- 21 g). For patients without prior MI, there were significant inverse correlations between infarct size and ejection fraction (r = 0.71, p less than 0.01) and wall motion score (r = 0.58, p less than 0.01) obtained from predischarge gated blood pool scans. Peak creatine kinase-MB correlated significantly with infarct size for patients without either reperfusion or right ventricular infarction (r = 0.66). Seven patients without prior infarcts had additional simultaneous indium-111/thallium-201 SPECT studies using dual energy windows.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Performance of Thallium-201 Electrocardiography-gated Myocardial Perfusion Single Photon Emission Computed Tomography to Assess Left Ventricular Function

    Directory of Open Access Journals (Sweden)

    Guang-Uei Hung

    2005-05-01

    Full Text Available This study evaluated the performance of gated single photon emission computed tomography (SPECT with thallium-201 (201Tl in assessing left ventricular ejection fraction (LVEF, end-diastolic volume (EDV, and end-systolic volume (ESV in Taiwanese by determining repeatability and correlation with two-dimensional (2D echocardiography. A total of 18 patients underwent two sequential gated SPECT acquisitions within 30 minutes in the resting state to assess repeatability. Another 28 patients who underwent gated SPECT and 2D echocardiography within 7 days were included for comparison. The two sequential measurements were well correlated with respect to LVEF, EDV, and ESV (r = 0.97, 0.95, and 0.97, respectively, all p < 0.0001. Bland-Altman analysis revealed that two standard deviations of the absolute difference between the two sequential measurements for LVEF, EDV, and ESV were 6.4%, 16.8 mL, and 8.6 mL, respectively. For LVEF, EDV, and ESV, correlations between redistribution 201Tl-gated SPECT and echocardiography were also excellent (all r = 0.83, p < 0.0001. LVEF was similar with 201Tl-gated SPECT and echocardiography, but EDV and ESV were significantly higher with echocardiography (p < 0.05. Our study revealed that 201Tl-gated SPECT has high repeatability and excellent correlation with echocardiography for the assessment of LVEF and volumes in Taiwanese. These results support the clinical application of gated SPECT in routine 201Tl myocardial perfusion imaging in Taiwanese.

  5. The Prognostic Role of Magnetic Resonance Imaging and Single-Photon Emission Computed Tomography in Viral Encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Misra, U.K.; Kalita, J.; Srivastav, A.; Pradhan, P.K. (Depts. of Neurology and Nuclear Medicine, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India))

    2008-09-15

    Background: There is a paucity of studies evaluating the prognostic role of magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) changes in viral encephalitis. Purpose: To study MRI and SPECT changes in patients with viral encephalitis, and to correlate these changes with clinical findings and outcome. Material and Methods: During 1997-2006, 31 encephalitis patients (aged 2-60 years; nine females, 22 males) underwent both MRI and SPECT studies. Their demographic and clinical data and 6-month outcome were recorded. For the diagnosis of encephalitis, polymerase chain reaction (PCR) and IgM enzyme-linked immunosorbent assay (ELISA) were carried out. Cranial MRI was done on a 1.5 T scanner, and 99mTc ethylene cysteine dimer (ECD) SPECT using a gamma camera. Outcome was defined at 6 months as complete, partial, or poor recovery. Results: 19 patients had Japanese encephalitis (JE), one had herpes simplex encephalitis (HSE), and 11 had nonspecific encephalitis. Movement disorders were present in 21, parkinsonian features in 19, and dystonia in 16 patients. MRI was abnormal in 20 patients, and revealed thalamic involvement in 17, basal ganglia in eight, brainstem in 11, and cortical in two. SPECT revealed hypoperfusion in 22 patients, which was cortical in 11, thalamic in 10, basal ganglia in six, and midbrain in one. Cortical involvement was more frequently found by SPECT and brainstem involvement by MRI. Outcome of encephalitis did not differ in the different groups of encephalitis and MRI changes. Conclusion: MRI and SPECT show a spectrum of findings in encephalitis, but these do not correlate with 6-month outcome

  6. Brain areas involved in acupuncture needling sensation of de qi: a single-photon emission computed tomography (SPECT) study.

    Science.gov (United States)

    Chen, Jia-Rong; Li, Gan-Long; Zhang, Gui-Feng; Huang, Yong; Wang, Shu-Xia; Lu, Na

    2012-12-01

    De qi is a sensory response elicited by acupuncture stimulation. According to traditional Chinese medicine (TCM), de qi is essential for clinical efficacy. However, the understanding of the neurobiological basis of de qi is still limited. To investigate the relationship between brain activation and de qi by taking a single-photon emission computed tomography (SPECT) scan while applying acupuncture at TE5. A total of 24 volunteers were randomly divided into 4 groups, and received verum or sham acupuncture at true acupuncture point TE5 or a nearby sham point according to grouping. All subjects then received a (99m)Tc-ethylcysteinate dimer (ECD) SPECT scan. All six subjects in the verum acupuncture at true acupuncture point group experienced de qi sensation; in contrast, all six subjects in the sham acupuncture at the sham point group responded with nothing other than non-sensation. Compared to the scan results from subjects who experienced non-sensation, SPECT scans from subjects with de qi sensation demonstrated significant activated points mainly located in brodmann areas 6, 8, 19, 21, 28, 33, 35, 37, 47, the parahippocampal gyrus, lentiform nucleus, claustrum and red nucleus; deactivated points were seen in brodmann areas 9 and 25. Verum acupuncture at true acupuncture points is more likely to elicit de qi sensation. De qi sensations mainly resulted in brain area activations, but not deactivations. These brain areas are related to the curative effect of Te5. The acupuncture needle sensations of de qi and sharp pain are associated with different patterns of activations and deactivations in the brain.

  7. Evaluation of acute myocardial infarction by 201Tl single-photon emission computed tomography using scoring system

    International Nuclear Information System (INIS)

    Setsuta, Koichi

    1991-01-01

    In 36 patients with acute myocardial infarction (AMI) 201 Tl single photon emission computed tomography (SPECT) examinations were performed in a relatively early phase of AMI. The short and long axis views of the left ventricle (LV) were divided into 6 segments. Images of each segment were assigned scores (segmental scores) based on a visual evaluation of the extent of 201 Tl accumulations. SPECT scores were compared with max GOT, max LDT, max CPK and max CK-MB, Killip classification and Forrester hemodynamic subset on admission, and LV ejection fraction (LVEF). Segmental scores were compared with LV wall motion evaluated by left ventriculography. The results are as follows: There were significant correlations between SPECT scores and max GOT, max LDH, max CPK and max CK-MB. SPECT scores in patients with Killip group III were significantly higher than in patients with Killip group I+II. However, no significant differences in max GOT, max LDH, max CPK and max CK-MB were observed between patients with Killip group III and those with Killip group I+II. SPECT scores were significantly higher in patients with Forrester group III+IV than in patients with Forrester group I+II. Segmental scores in segments evaluated as akinesis, dyskinesis and aneurysm by left ventriculography were significantly higher than those evaluated as hypokinesis or normal. Segmental scores in segments evaluated as hypokinesis were significantly high in comparison with normal segments. Significant correlations were observed between LVEF and SPECT scores. However, LVEF correlated poorly with max GOT, max LDH and max CPK, and no significant correlation was observed between LVEF and max CK-MB. SPECT examinations were performed in 11 patients in both the acute and chronic phase of AMI. SPECT scores in the chronic phase did not change in 4 patients, decreased in 5, increased in 2. These results suggest that SPECT scores and segmental scores can be useful indices in the evaluation of AMI. (J.P.N.)

  8. Single photon ECT

    International Nuclear Information System (INIS)

    Maeda, Toshio; Matsuda, Hiroshi; Tada, Akira; Bunko, Hisashi; Koizumi, Kiyoshi

    1982-01-01

    The detectability of lesions located deep in a body or overlapped with a physiologically increased activity improve with the help of single photon ECT. In some cases, the ECT is superior to the conventional gamma camera images and X-ray CT scans in the evaluation of the location and size of lesion. The single photon ECT of the brain compares favorably with the contrast enhansed X-ray CT scans. The most important adaptation of the single photon ECT are the detection of recurrent brain tumors after craniotomy and the evaluation of ischemic heart diseases. (author)

  9. Post meningitis subdural hygroma: Anatomical and functional evaluation with 99mTc-ehylene cysteine dimer single photon emission tomography/computed tomography

    OpenAIRE

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. 99mTc-ehylene cysteine dimer (99mTc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cereb...

  10. The distribution of cerebral muscarinic acetylcholine receptors in vivo in patients with dementia. A controlled study with 123IQNB and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Weinberger, D.R.; Gibson, R.; Coppola, R.; Jones, D.W.; Molchan, S.; Sunderland, T.; Berman, K.F.; Reba, R.C.

    1991-01-01

    A high-affinity muscarinic receptor antagonist, 123IQNB (3-quinuclidinyl-4-iodobenzilate labeled with iodine 123), was used with single photon emission computed tomography to image muscarinic acetylcholine receptors in 14 patients with dementia and in 11 healthy controls. High-resolution single photon emission computed tomographic scanning was performed 21 hours after the intravenous administration of approximately 5 mCi of IQNB. In normal subjects, the images of retained ligand showed a consistent regional pattern that correlated with postmortem studies of the relative distribution of muscarinic receptors in the normal human brain, having high radioactivity counts in the basal ganglia, occipital cortex, and insular cortex, low counts in the thalamus, and virtually no counts in the cerebellum. Eight of 12 patients with a clinical diagnosis of Alzheimer's disease had obvious focal cortical defects in either frontal or posterior temporal cortex. Both patients with a clinical diagnosis of Pick's disease had obvious frontal and anterior temporal defects. A region of interest statistical analysis of relative regional activity revealed a significant reduction bilaterally in the posterior temporal cortex of the patients with Alzheimer's disease compared with controls. This study demonstrates the practicability of acetylcholine receptor imaging with 123IQNB and single photon emission computed tomography. The data suggest that focal abnormalities in muscarinic binding in vivo may characterize some patients with Alzheimer's disease and Pick's disease, but further studies are needed to address questions about partial volume artifacts and receptor quantification

  11. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis

    International Nuclear Information System (INIS)

    Fintel, D.J.; Links, J.M.; Brinker, J.A.; Frank, T.L.; Parker, M.; Becker, L.C.

    1989-01-01

    Qualitative interpretation of tomographic and planar scintigrams, a five point rating scale and receiver operating characteristic analysis were utilized to compare single photon emission computed tomography and conventional planar imaging of myocardial thallium-201 uptake in the accuracy of the diagnosis of coronary artery disease and individual vessel involvement. One hundred twelve patients undergoing cardiac catheterization and 23 normal volunteers performed symptom-limited treadmill exercise, followed by stress and redistribution imaging by both tomographic and planar techniques, with the order determined randomly. Paired receiver operating characteristic curves revealed that single photon emission computed tomography was more accurate than planar imaging over the entire range of decision thresholds for the overall detection and exclusion of coronary artery disease and involvement of the left anterior descending and left circumflex coronary arteries. Tomography offered relatively greater advantages in male patients and in patients with milder forms of coronary artery disease, who had no prior myocardial infarction, only single vessel involvement or no lesion greater than or equal to 50 to 69%. Tomography did not appear to provide improved diagnosis in women or in detection of disease in the right coronary artery. Although overall detection of coronary artery disease was not improved in patients with prior myocardial infarction, tomography provided improved identification of normal and abnormal vascular regions. These results indicate that single photon emission computed tomography provides improved diagnostic performance compared with planar imaging in many clinical subgroups

  12. Multimodal imaging analysis of single-photon emission computed tomography and magnetic resonance tomography for improving diagnosis of Parkinson's disease

    International Nuclear Information System (INIS)

    Barthel, H.; Georgi, P.; Slomka, P.; Dannenberg, C.; Kahn, T.

    2000-01-01

    Parkinson's disease (PD) is characterized by a degeneration of nigrostriated dopaminergic neurons, which can be imaged with 123 I-labeled 2β-carbomethoxy-3β-(4-iodophenyl) tropane ([ 123 I]β-CIT) and single-photon emission computed tomography (SPECT). However, the quality of the region of interest (ROI) technique used for quantitative analysis of SPECT data is compromised by limited anatomical information in the images. We investigated whether the diagnosis of PD can be improved by combining the use of SPECT images with morphological image data from magnetic resonance imaging (MRI)/computed tomography (CT). We examined 27 patients (8 men, 19 women; aged 55±13 years) with PD (Hoehn and Yahr stage 2.1±0.8) by high-resolution [ 123 I]β-CIT SPECT (185-200 MBq, Ceraspect camera). SPECT images were analyzed both by a unimodal technique (ROIs defined directly within the SPECT studies) and a multimodal technique (ROIs defined within individual MRI/CT studies and transferred to the corresponding interactively coregistered SPECT studies). [ 123 I]β-CIT binding ratios (cerebellum as reference), which were obtained for heads of caudate nuclei (CA), putamina (PU), and global striatal structures were compared with clinical parameters. Differences between contra- and ipsilateral (related to symptom dominance) striatal [ 123 I]β-CIT binding ratios proved to be larger in the multimodal ROI technique than in the unimodal approach (e.g., for PU: 1.2*** vs. 0.7**). Binding ratios obtained by the unimodal ROI technique were significantly correlated with those of the multimodal technique (e.g., for CA: y=0.97x+2.8; r=0.70; P com subscore (r=-0.49* vs. -0.32). These results show that the impact of [ 123 I]β-CIT SPECT for diagnosing PD is affected by the method used to analyze the SPECT images. The described multimodal approach, which is based on coregistration of SPECT and morphological imaging data, leads to improved determination of the degree of this dopaminergic disorder

  13. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  14. A case of dual ectopy thyroid along the thyroglossal tract demonstrated on 99mTc-Pertechnatate hybrid single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Karunanithi, Sellam; Jain, Sachin; Tripathi, Madhavi

    2014-01-01

    Ectopic thyroid tissue (ETT) refers to the presence of thyroid tissue in locations other than the normal anterior neck region between the second and fourth tracheal cartilages. Multiple ectopia of the thyroid is extremely rare. Here we report a case of 10-year-old girl with anterior midline neck swelling and hypothyroidism with dual ectopia of thyroid gland without orthotopic thyroid gland. Planar 99 m-technetium pertechnatate scan identified ETT corresponding to the palpable neck swelling. Single photon emission computed tomography/computed tomography (SPECT/CT) demonstrated ETT in two locations, one corresponding to the palpable mass and another in the in the sublingual location. This case thus demonstrates the important role of hybrid SPECT/CT in the identification of dual ectopia along the thyroglossal tract

  15. Improving appropriate use of echocardiography and single-photon emission computed tomographic myocardial perfusion imaging: a continuous quality improvement initiative.

    Science.gov (United States)

    Johnson, Thomas V; Rose, Geoffrey A; Fenner, Deborah J; Rozario, Nigel L

    2014-07-01

    Appropriate use criteria for cardiovascular imaging have been published, but compliance in practice has been incomplete, with persistent high rates of inappropriate use. The aim of this study was to show the efficacy of a continuous quality improvement (CQI) initiative to favorably influence the appropriate use of outpatient transthoracic echocardiography and single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (MPI) in a large cardiovascular practice. In this prospective study, a multiphase CQI initiative was implemented, and its impact on ordering patterns for outpatient transthoracic echocardiography and SPECT MPI was assessed. Between November and December 2010, a baseline analysis of the application of appropriate use criteria to indications for outpatient transthoracic echocardiographic studies (n = 203) and SPECT MPI studies (n = 205) was performed, with studies categorized as "appropriate," "inappropriate," "uncertain," or "unclassified." The CQI initiative was then begun, with (1) clinician education, including didactic lectures and case-based presentations with audience participation; (2) system changes in ordering processes, with redesigned image ordering forms; and (3) peer review and feedback. A follow-up analysis was then performed between June and August 2012, with categorization of indications for transthoracic echocardiographic studies (n = 206) and SPECT MPI studies (n = 206). At baseline, 73.9% of echocardiographic studies were categorized as appropriate, 16.7% as inappropriate, 5.9% as uncertain, and 3.4% as unclassified. Similarly, for SPECT MPI studies 71.7% were categorized as appropriate, 18.5% as inappropriate, 7.8% as uncertain, and 1.9% as unclassified. Separate analysis of the two most important categories, appropriate and inappropriate, demonstrated a significant improvement after the CQI initiative, with a 63% reduction in inappropriate echocardiographic studies (18.5% vs 6.9%, P = .0010) and a 46% reduction

  16. Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software.

    Science.gov (United States)

    Aldridge, Matthew D; Waddington, Wendy W; Dickson, John C; Prakash, Vineet; Ell, Peter J; Bomanji, Jamshed B

    2013-11-01

    A three-dimensional model-based resolution recovery (RR) reconstruction algorithm that compensates for collimator-detector response, resulting in an improvement in reconstructed spatial resolution and signal-to-noise ratio of single-photon emission computed tomography (SPECT) images, was tested. The software is said to retain image quality even with reduced acquisition time. Clinically, any improvement in patient throughput without loss of quality is to be welcomed. Furthermore, future restrictions in radiotracer supplies may add value to this type of data analysis. The aims of this study were to assess improvement in image quality using the software and to evaluate the potential of performing reduced time acquisitions for bone and parathyroid SPECT applications. Data acquisition was performed using the local standard SPECT/CT protocols for 99mTc-hydroxymethylene diphosphonate bone and 99mTc-methoxyisobutylisonitrile parathyroid SPECT imaging. The principal modification applied was the acquisition of an eight-frame gated data set acquired using an ECG simulator with a fixed signal as the trigger. This had the effect of partitioning the data such that the effect of reduced time acquisitions could be assessed without conferring additional scanning time on the patient. The set of summed data sets was then independently reconstructed using the RR software to permit a blinded assessment of the effect of acquired counts upon reconstructed image quality as adjudged by three experienced observers. Data sets reconstructed with the RR software were compared with the local standard processing protocols; filtered back-projection and ordered-subset expectation-maximization. Thirty SPECT studies were assessed (20 bone and 10 parathyroid). The images reconstructed with the RR algorithm showed improved image quality for both full-time and half-time acquisitions over local current processing protocols (Pimproved image quality compared with local processing protocols and has been

  17. Single-photon imaging

    International Nuclear Information System (INIS)

    Seitz, Peter; Theuwissen, Albert J.P.

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist's view from different domains to the forthcoming ''single-photon imaging'' revolution. The various aspects of single-photon imaging are treated by internationally renowned, leading scientists and technologists who have all pioneered their respective fields. (orig.)

  18. Development of (99m)Tc-labeled asymmetric urea derivatives that target prostate-specific membrane antigen for single-photon emission computed tomography imaging.

    Science.gov (United States)

    Kimura, Hiroyuki; Sampei, Sotaro; Matsuoka, Daiko; Harada, Naoya; Watanabe, Hiroyuki; Arimitsu, Kenji; Ono, Masahiro; Saji, Hideo

    2016-05-15

    Prostate-specific membrane antigen (PSMA) is expressed strongly in prostate cancers and is, therefore, an attractive diagnostic and radioimmunotherapeutic target. In contrast to previous reports of PMSA-targeting (99m)Tc-tricarbonyl complexes that are cationic or lack a charge, no anionic (99m)Tc-tricarbonyl complexes have been reported. Notably, the hydrophilicity conferred by both cationic and anionic charges leads to rapid hepatobiliary clearance, whereas an anionic charge might better enhance renal clearance relative to a cationic charge. Therefore, an improvement in rapid clearance would be expected with either cationic or anionic charges, particularly anionic charges. In this study, we designed and synthesized a novel anionic (99m)Tc-tricarbonyl complex ([(99m)Tc]TMCE) and evaluated its use as a single-photon emission computed tomography (SPECT) imaging probe for PSMA detection. Direct synthesis of [(99m)Tc]TMCE from dimethyl iminodiacetate, which contains both the asymmetric urea and succinimidyl moiety important for PSMA binding, was performed using our microwave-assisted one-pot procedure. The chelate formation was successfully achieved even though the precursor included a complicated bioactive moiety. The radiochemical yield of [(99m)Tc]TMCE was 12-17%, with a radiochemical purity greater than 98% after HPLC purification. [(99m)Tc]TMCE showed high affinity in vitro, with high accumulation in LNCaP tumors and low hepatic retention in biodistribution and SPECT/CT studies. These findings warrant further evaluation of [(99m)Tc]TMCE as an imaging agent and support the benefit of this strategy for the design of other PSMA imaging probes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Post meningitis subdural hygroma: Anatomical and functional evaluation with (99m)Tc-ehylene cysteine dimer single photon emission tomography/computed tomography.

    Science.gov (United States)

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. (99m)Tc-ehylene cysteine dimer ((99m)Tc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cerebral hypoperfusion. If (99m)Tc-ECD SPECT/CT is integrated into management of these patients, it can help in decision making with respect to conservative versus surgical management.

  20. Association of Novelty Seeking Scores and Striatal Dopamine D2/D3 Receptor Availability of Healthy Volunteers: Single Photon Emission Computed Tomography With 123I-iodobenzamide

    Directory of Open Access Journals (Sweden)

    Hsiang Yu Huang

    2010-10-01

    Full Text Available It has been speculated that novelty seeking (NS behavior is related to the dopaminergic system. Fifty-two subjects completed the Tridimensional Personality Questionnaire and underwent single photon emission computed tomography with 123I-iodobenzamide. A marginally positive correlation was noted between NS and striatal dopamine D2/D3 receptor availability (r = 0.25, p =0.07. A positive association was noted between the NS scores and left striatal D2/D3 receptor availability (r= 0.29, p =0.04. The results suggest that a relationship might exist between NS score and dopaminergic activity.

  1. Degenerative dementia: nosological aspects and results of single photon emission computed tomography; Les demences degeneratives: aspects nosologiques et resultats de la tomographie d'emission monophotonique

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, B.; Habert, M.O. [Hopital Pitie-Salpetriere, 75 - Paris (France)

    1999-12-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  2. Hemimegalencephaly: a rare cause of hemihypoperfusion on 99m technetium-ethyl cysteinate dimer brain perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Damle, Nishikant A.; Singhal, Abhinav; Mukherjee, Anirban; Sahoo, Manas Kumar; Tripathi, Madhavi; Bal, Chandrasekhar

    2013-01-01

    Hemimegalencephaly is a rare congenital neuronal migration disorder that can presents with the equally rare finding of hemihypoperfusion on brain perfusion single-photon emission computed tomography (SPECT). It is an extremely rare cause of intractable epilepsy. Technetium-99m ethyl cysteinate dimer (ECD) brain perfusion SPECT is useful in excluding other foci of hypoperfusion in the contralateral since hemispherectomy has been suggested to be the treatment of choice. Furthermore, hemimegalencephaly may present with hyper as well as hypoperfusion on ECD SPECT. We present the case of an 11-year-old male child with intractable seizures who showed hemihypoperfusion in the hemimegalecephalic hemisphere. (author)

  3. The use of combined single photon emission computed tomography and X-ray computed tomography to assess the fate of inhaled aerosol.

    Science.gov (United States)

    Fleming, John; Conway, Joy; Majoral, Caroline; Tossici-Bolt, Livia; Katz, Ira; Caillibotte, Georges; Perchet, Diane; Pichelin, Marine; Muellinger, Bernhard; Martonen, Ted; Kroneberg, Philipp; Apiou-Sbirlea, Gabriela

    2011-02-01

    Gamma camera imaging is widely used to assess pulmonary aerosol deposition. Conventional planar imaging provides limited information on its regional distribution. In this study, single photon emission computed tomography (SPECT) was used to describe deposition in three dimensions (3D) and combined with X-ray computed tomography (CT) to relate this to lung anatomy. Its performance was compared to planar imaging. Ten SPECT/CT studies were performed on five healthy subjects following carefully controlled inhalation of radioaerosol from a nebulizer, using a variety of inhalation regimes. The 3D spatial distribution was assessed using a central-to-peripheral ratio (C/P) normalized to lung volume and for the right lung was compared to planar C/P analysis. The deposition by airway generation was calculated for each lung and the conducting airways deposition fraction compared to 24-h clearance. The 3D normalized C/P ratio correlated more closely with 24-h clearance than the 2D ratio for the right lung [coefficient of variation (COV), 9% compared to 15% p computer analysis is a useful approach for applications requiring regional information on deposition.

  4. Comparison of planar scanning and single photon emission computed tomography in the diagnosis of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Feiglin, D.H.I.; Levine, M.; Stulberg, B.; Pflanze, W.; O'Donnell, J.K.; Belhobek, G.H.; Go, R.T.; MacIntyre, W.J.

    1986-01-01

    Thirty-nine patients were investigated for avascular necrosis of the femoral head. All hips were studied by plain x-ray and MR imaging, 70 hips studied by radionuclide bone scanning, and 38 were studied by single photon emission CT (SPECT). Core biopsies of the femoral heads from 32 hips were examined. No one reference standard for noninvasive diagnosis of this disease is available. The sensitivity and specificity of the radionuclide studies with respect to SPECT were 77% and 100%; of SPECT with respect to pathologic confirmation, 100% and 57%; of MR imaging with respect to pathologic studies, 100% and 66%. Pathologic sampling is subject to error and may give false negative results with spuriously low specificities for imaging modalities. SPECT is recommended as the radionuclide imaging procedure of choice for detecting avascular necrosis of the femoral head

  5. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Amthauer, H.; Denecke, T.; Ruf, J.; Gutberlet, M.; Felix, R.; Lemke, A.J.; Rohlfing, T.; Boehmig, M.; Ploeckinger, U.

    2005-01-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations. (orig.)

  6. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  7. Influence of the Pixel Sizes of Reference Computed Tomography on Single-photon Emission Computed Tomography Image Reconstruction Using Conjugate-gradient Algorithm.

    Science.gov (United States)

    Okuda, Kyohei; Sakimoto, Shota; Fujii, Susumu; Ida, Tomonobu; Moriyama, Shigeru

    The frame-of-reference using computed-tomography (CT) coordinate system on single-photon emission computed tomography (SPECT) reconstruction is one of the advanced characteristics of the xSPECT reconstruction system. The aim of this study was to reveal the influence of the high-resolution frame-of-reference on the xSPECT reconstruction. 99m Tc line-source phantom and National Electrical Manufacturers Association (NEMA) image quality phantom were scanned using the SPECT/CT system. xSPECT reconstructions were performed with the reference CT images in different sizes of the display field-of-view (DFOV) and pixel. The pixel sizes of the reconstructed xSPECT images were close to 2.4 mm, which is acquired as originally projection data, even if the reference CT resolution was varied. The full width at half maximum (FWHM) of the line-source, absolute recovery coefficient, and background variability of image quality phantom were independent on the sizes of DFOV in the reference CT images. The results of this study revealed that the image quality of the reconstructed xSPECT images is not influenced by the resolution of frame-of-reference on SPECT reconstruction.

  8. Quantification of myocardial area at risk in the absence of collateral flow: the validation of angiographic scores by myocardial perfusion single-photon emission computed tomography.

    Science.gov (United States)

    Rodríguez-Palomares, José F; Alonso, Albert; Martí, Gerard; Aguadé-Bruix, Santiago; González-Alujas, M T; Romero-Farina, Guillermo; Candell-Riera, Jaume; García del Blanco, Bruno; Evangelista, Artur; García-Dorado, David

    2013-02-01

    Our study aimed to compare the area at risk (AAR) determined by single-photon emission computed tomography (SPECT) with the Bypass Angioplasty Revascularization Investigation (BARI) and modified Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) angiographic scores in the setting of patients undergoing coronary angioplasty for either unstable angina or an STEMI. Radionuclide myocardial perfusion imaging prior to reperfusion has classically been the most widely practised technique for assessing the AAR and has been successfully used to compare the efficacy of various reperfusion strategies in patients with an ST-segment elevation myocardial infarction (STEMI). The BARI and modified APPROACH scores are angiographic methods widely used to provide a rapid estimation of the AAR; however, they have not been directly validated with myocardial perfusion single-photon emission computed tomography (SPECT). Fifty-five patients with no previous myocardial infarction who underwent coronary angioplasty for single-vessel disease (unstable angina: n = 25 or an STEMI: n = 30) with no evidence of collaterals (Rentrop Collateral Score collateral flow, BARI and APPROACH scores constitute valid methods for AAR estimation in current clinical practice, with more accurate results when used for the LAD territory; both are useful not only in STEMI patients but also in patients with unstable angina.

  9. Regional cerebral blood flow single photon emission computed tomography for detection of Frontotemporal dementia in people with suspected dementia.

    Science.gov (United States)

    Archer, Hilary A; Smailagic, Nadja; John, Christeena; Holmes, Robin B; Takwoingi, Yemisi; Coulthard, Elizabeth J; Cullum, Sarah

    2015-06-23

    In the UK, dementia affects 5% of the population aged over 65 years and 25% of those over 85 years. Frontotemporal dementia (FTD) represents one subtype and is thought to account for up to 16% of all degenerative dementias. Although the core of the diagnostic process in dementia rests firmly on clinical and cognitive assessments, a wide range of investigations are available to aid diagnosis.Regional cerebral blood flow (rCBF) single-photon emission computed tomography (SPECT) is an established clinical tool that uses an intravenously injected radiolabelled tracer to map blood flow in the brain. In FTD the characteristic pattern seen is hypoperfusion of the frontal and anterior temporal lobes. This pattern of blood flow is different to patterns seen in other subtypes of dementia and so can be used to differentiate FTD.It has been proposed that a diagnosis of FTD, (particularly early stage), should be made not only on the basis of clinical criteria but using a combination of other diagnostic findings, including rCBF SPECT. However, more extensive testing comes at a financial cost, and with a potential risk to patient safety and comfort. To determine the diagnostic accuracy of rCBF SPECT for diagnosing FTD in populations with suspected dementia in secondary/tertiary healthcare settings and in the differential diagnosis of FTD from other dementia subtypes. Our search strategy used two concepts: (a) the index test and (b) the condition of interest. We searched citation databases, including MEDLINE (Ovid SP), EMBASE (Ovid SP), BIOSIS (Ovid SP), Web of Science Core Collection (ISI Web of Science), PsycINFO (Ovid SP), CINAHL (EBSCOhost) and LILACS (Bireme), using structured search strategies appropriate for each database. In addition we searched specialised sources of diagnostic test accuracy studies and reviews including: MEDION (Universities of Maastricht and Leuven), DARE (Database of Abstracts of Reviews of Effects) and HTA (Health Technology Assessment) database

  10. Skull base osteomyelitis in otitis externa: The utility of triphasic and single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Gupta, Ashok Kumar; Panda, Naresh Kumar; Das, Ashim; Mittal, Bhagwant Rai

    2013-01-01

    Skull base osteomyelitis (SBO) refers to infection that has spread beyond the external auditory canal to the base of the skull in advanced stages of otitis externa. Clinically, it may be difficult to differentiate SBO from severe otitis externa without bony involvement. This study was performed to determine the role of three phase bone scintigraphy (TPBS) and single photon emission tomography/computed tomography (SPECT/CT) in detecting SBO. We retrospectively analyzed records of 20 patients (14 M, 6 F) with otitis externa and suspected SBO. TPBS and SPECT/CT of the skull were performed. Findings were correlated with clinical, laboratory and diagnostic CT scan findings. All patients were diabetic with elevated erythrocyte sedimentation rate. A total of 18 patients had bilateral and two unilateral symptoms. Cranial nerves were involved in eight patients and microbiological culture of ear discharge fluid positive in seven. Early images showed increased temporal vascularity in nine patients and increased soft-tissue uptake in 10, while delayed images showed increased bone uptake in 19/20 patients. Localized abnormal tracer uptake was shown by SPECT/CT in the mastoid temporal (15), petrous (11), sphenoid (3) and zygomatic (1) and showed destructive changes in five. Thus, TPBS was found positive for SBO in 10/20 patients and changed the management in four. Our study suggests that TPBS with SPECT/CT is a useful non-invasive investigation for detection of SBO in otitis externa

  11. Single photon emission computed tomography procedure improves accuracy of somatostatin receptor scintigraphy in endocrine gastro-entero-pancreatic tumours

    International Nuclear Information System (INIS)

    Lebtahi, R.; Genin, R.; Rouzet, F.; Bleicner-Perez, S.; Lievre, A.; Scigliano, S.; Vialle, C.; Le Guludec, D.; Cadiot, G.; Sobhani, I.; Mignon, M.

    2005-01-01

    Somatostatin receptors scintigraphy (SRS) is a sensitive method for the detection of endocrine gastro-entero-pancreatic tumors. The aim of this study was to evaluate the sensitivity of anterior and posterior planar associated to single photon emission computerized tomography (SPECT) compared to anterior and posterior planar associated to additional lateral and oblique views in the detection of abdominal endocrine tumors. One hundred and sixty four patients with endocrine gastro-entero-pancreatic tumors were included in this study. Scintigraphic images were performed after injection of 189 ± 23 MBq of 111 In-Pentetreotide. Abdominal planar images were performed 4 h and 24 hours after injection. Abdominal SPECT was performed at 24 hours. The combination of anterior and posterior abdominal planar images with SPECT using iterative reconstruction detected significantly more tumoral sites compared to multiple planar images (298 versus 280 for the liver, p = 0.01 and 90 versus 88 for coeliac area). In particular liver lesions were better delineated on tomographic slices. The combination of 111 In-Pentetreotide SPECT with anterior and posterior planar images is more sensitive than multiple planar images to detect abdominal endocrine tumors. (author)

  12. Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions

    International Nuclear Information System (INIS)

    Das, S.K.; Miften, M.M.; Zhou, S.; Bell, M.; Munley, M.T.; Whiddon, C.S.; Craciunescu, O.; Baydush, A.H.; Wong, T.; Rosenman, J.G.; Dewhirst, M.W.; Marks, L.B.

    2004-01-01

    The information provided by functional images may be used to guide radiotherapy planning by identifying regions that require higher radiation dose. In this work we investigate the dosimetric feasibility of delivering dose to lung tumors in proportion to the fluorine-18-fluorodeoxyglucose activity distribution from positron emission tomography (FDG-PET). The rationale for delivering dose in proportion to the tumor FDG-PET activity distribution is based on studies showing that FDG uptake is correlated to tumor cell proliferation rate, which is shown to imply that this dose delivery strategy is theoretically capable of providing the same duration of local control at all voxels in tumor. Target dose delivery was constrained by single photon emission computed tomography (SPECT) maps of normal lung perfusion, which restricted irradiation of highly perfused lung and imposed dose-function constraints. Dose-volume constraints were imposed on all other critical structures. All dose-volume/function constraints were considered to be soft, i.e., critical structure doses corresponding to volume/function constraint levels were minimized while satisfying the target prescription, thus permitting critical structure doses to minimally exceed dose constraint levels. An intensity modulation optimization methodology was developed to deliver this radiation, and applied to two lung cancer patients. Dosimetric feasibility was assessed by comparing spatially normalized dose-volume histograms from the nonuniform dose prescription (FDG-PET proportional) to those from a uniform dose prescription with equivalent tumor integral dose. In both patients, the optimization was capable of delivering the nonuniform target prescription with the same ease as the uniform target prescription, despite SPECT restrictions that effectively diverted dose from high to low perfused normal lung. In one patient, both prescriptions incurred similar critical structure dosages, below dose-volume/function limits

  13. Studies on the hepatosplenic volume and the accumulation rate of 99mTc Sn colloid in patients with liver cirrhosis by using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Sato, Shizou; Mimura, Hisashi; Noda, Takuo; Hamazaki, Keisuke; Takakura, Norio; Tsuge, Hiroshi; Awai, Sachio; Hiraki, Yoshio; Orita, Kunzo

    1988-01-01

    The method using single photon emission computed tomography (SPECT) for measurement of the hepatosplenic volume and the accumulation rate of 99m Tc Sn colloid was studied, and applied to patients with liver cirrhosis. The hepatosplenic volume calculated by this method was well correlated with that by computed tomography (r = 0.938). The accumulation rate obtained by this method was almost equal to that by whole body scintigraphy. In liver cirrhosis (Child B and C group) the liver volume was atrophic and the splenic volume hypertrophic. The liver accumulation rate was decreased corresponding with the degree of liver cirrhosis, but the accumulation rate per volume was decreased in Child B and C. The splenic accumulation rate was increased in Child B and C, but the accumulation rate per volume was not significant between control group and liver cirrhosis. The measurement of the hepatosplenic volume and accumulation rate by SPECT is useful to evaluate the hepatosplenic function. (author)

  14. An incidentally found inflamed uterine myoma Causing low abdominal pain, using TC-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zandieh, Shahin; Schuetz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg [Hanusch-Hospital, Teaching Hospital of Medical University of Vienna, Vienna (Australia)

    2013-10-15

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  15. Novel application of quantitative single-photon emission computed-tomography/computed tomography to predict early response to methimazole in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Bang, Ji In; Kim, Ji Young; Moon, Jae Hoon [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University Medical Center, Seoul (Korea, Republic of); Lee, Won Woo [Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul (Korea, Republic of)

    2017-06-15

    Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of {sup 99m}Tc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). A novel parameter of thyroid uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients.

  16. Possibilities of the new hybrid technology single photon emission computer technology/computer tomography (SPECT/CT) and the first impressions of its application

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2010-01-01

    With the help of the new hybrid technique SPECT/ CT it is possible, using the only investigation, to acquire a combine image of the investigated organ, visualizing its function and structure. Combining the possibilities of the new multimodality method, which combines the possibilities of the Single Photon Emission Computer Tomography - SPECT and Computer Tomography - CT, it is possible to precisely localize the pathologically changed organs function. With the further combination of the tomographic gamma camera with diagnostic CT, a detailed morphological evaluation of the finding was possible. The main clinical application of the new hybrid diagnostic is in the fields of cardiology, oncology, orthopedics with more and more extension of those, not connected with oncology, such as - thyroid, parathyroid, brain (especially localization of the epileptic foci), visualization of local infection and recently for the purposes of the radiotherapy planning. According to the literature data, around 35% of SPECT-investigations have to be combined with CT in order to increase the specificity of the diagnosis, which changes the interpretation of the result in 56% of the cases. After installation of the SPECT/CT camera in the University hospital 'Alexandrovska' in January 2009, the following changes have been done: the number of the investigated patients have increased, including number of heart, thyroid (especially scintigraphy with 131I), bones and parathyroid glands. As a result of the application of the hybrid technique, a shortage of the investigated time was realized and a decrease prize in comparison with the individual application of the investigations. Summarizing the literature data and the preliminary impression of the first multimodality scanner in our country in the University hospital 'Alexandrovska' it could be said, that there is continuously increasing information for the new clinical applications of SPECT/CT. It is now accepted, that its usage will increase in

  17. Comparison of Single-Photon Emission Computed Tomography-Computed Tomography (SPECT/CT) and Conventional Planar Lymphoscintigraphy for Sentinel Node Localization in Patients with Cutaneous Malignancies.

    Science.gov (United States)

    Doepker, Matthew P; Yamamoto, Maki; Applebaum, Matthew A; Patel, Nupur U; Jaime Montilla-Soler, M; Sarnaik, Amod A; Wayne Cruse, C; Sondak, Vernon K; Zager, Jonathan S

    2017-02-01

    Accurate preoperative lymphoscintigraphy is vital to performing sentinel lymph node biopsy (SLNB) for cutaneous malignancies. Potential advantages of single-photon emission computed tomography with integrated computed tomography (SPECT/CT) include the ability to readily identify aberrant drainage patterns as well as provide the surgeon with three-dimensional anatomic landmarks not seen on conventional planar lymphoscintigraphy (PLS). Patients with cutaneous malignancies who underwent SLNB with preoperative imaging using both SPECT/CT and PLS from 2011 to 2014 were identified. Both SPECT/CT and PLS were obtained in 351 patients (median age, 69 years; range, 5-94 years) with cutaneous malignancies (melanoma = 300, Merkel cell carcinoma = 33, squamous cell carcinoma = 8, other = 10) after intradermal injection of 99m technetium sulfur colloid (median dose 300 µCi). A mean of 4.3 hot spots were identified on SPECT/CT compared to 3.0 on PLS (p CT and PLS, while 172 (49 %) had additional hot spots identified on SPECT/CT compared to only 24 (6.8 %) additional on PLS. SPECT/CT demonstrated additional nodal basins in 103 patients (29.4 %), compared to only 11 patients (3.1 %) with additional basins on PLS. SPECT/CT is a useful adjunct that can help with sentinel node localization in challenging cases. It identified additional hot spots not seen on PLS in almost 50 % of patients. Because PLS identified hot spots not seen on SPECT/CT in 6.8 % of patients, we recommend using both modalities jointly. Long-term follow-up will be required to validate the clinical significance of the additional hot spots identified by SPECT/CT.

  18. Applying standardized uptake values in gallium-67-citrate single-photon emission computed tomography/computed tomography studies and their correlation with blood test results in representative organs.

    Science.gov (United States)

    Toriihara, Akira; Daisaki, Hiromitsu; Yamaguchi, Akihiro; Yoshida, Katsuya; Isogai, Jun; Tateishi, Ukihide

    2018-05-21

    Recently, semiquantitative analysis using standardized uptake value (SUV) has been introduced in bone single-photon emission computed tomography/computed tomography (SPECT/CT). Our purposes were to apply SUV-based semiquantitative analytic method for gallium-67 (Ga)-citrate SPECT/CT and to evaluate correlation between SUV of physiological uptake and blood test results in representative organs. The accuracy of semiquantitative method was validated using an National Electrical Manufacturers Association body phantom study (radioactivity ratio of sphere : background=4 : 1). Thereafter, 59 patients (34 male and 25 female; mean age, 66.9 years) who had undergone Ga-citrate SPECT/CT were retrospectively enrolled in the study. A mean SUV of physiological uptake was calculated for the following organs: the lungs, right atrium, liver, kidneys, spleen, gluteal muscles, and bone marrow. The correlation between physiological uptakes and blood test results was evaluated using Pearson's correlation coefficient. The phantom study revealed only 1% error between theoretical and actual SUVs in the background, suggesting the sufficient accuracy of scatter and attenuation corrections. However, a partial volume effect could not be overlooked, particularly in small spheres with a diameter of less than 28 mm. The highest mean SUV was observed in the liver (range: 0.44-4.64), followed by bone marrow (range: 0.33-3.60), spleen (range: 0.52-2.12), and kidneys (range: 0.42-1.45). There was no significant correlation between hepatic uptake and liver function, renal uptake and renal function, or bone marrow uptake and blood cell count (P>0.05). The physiological uptake in Ga-citrate SPECT/CT can be represented as SUVs, which are not significantly correlated with corresponding blood test results.

  19. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    International Nuclear Information System (INIS)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo

    2016-01-01

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment

  20. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2016-06-15

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment.

  1. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Uetani, Teruyoshi; Kono, Tamami; Ogimoto, Akiyoshi [Ehime University Graduate School of Medicine, Department of Cardiology, Pulmonology, Hypertension and Nephrology, Toon, Ehime (Japan); Soma, Tsutomu [FUJIFILM RI Pharma Co., Ltd., QMS Group, Quality Assurance Department, Tokyo (Japan); Graduate School of Medicine, University of Tokyo, Department of Radiology, Tokyo (Japan); Murase, Kenya [Osaka University Graduate School of Medicine, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Osaka (Japan); Iwaki, Hirotaka [Ehime University Graduate School of Medicine, Center for Clinical Research Data and Biostatistics, Toon, Ehime (Japan)

    2016-11-15

    To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) or single-photon emission computed tomography (SPECT). Fifty-three patients who underwent stress dynamic CTP and either SPECT (n = 25) or CMR (n = 28) were retrospectively selected. Normal and abnormal perfused myocardium (ischemia/infarction) were assessed by SPECT/CMR using 16-segment model. Sensitivity and specificity of CT-MBF (mL/g/min) for detecting the ischemic/infarction and severe infarction were assessed. The abnormal perfused myocardium and severe infarction were seen in SPECT (n = 90 and n = 19 of 400 segments) and CMR (n = 223 and n = 36 of 448 segments). For detecting the abnormal perfused myocardium, sensitivity and specificity were 80 % (95 %CI, 71-90) and 86 % (95 %CI, 76-91) in SPECT (cut-off MBF, 1.23), and 82 % (95 %CI, 76-88) and 87 % (95 %CI, 80-92) in CMR (cut-off MBF, 1.25). For detecting severe infarction, sensitivity and specificity were 95 % (95 %CI, 52-100) and 72 % (95 %CI, 53-91) in SPECT (cut-off MBF, 0.92), and 78 % (95 %CI, 67-97) and 80 % (95 %CI, 58-86) in CMR (cut-off MBF, 0.98), respectively. Dynamic CTP has a potential to detect abnormal perfused myocardium and severe infarction assessed by SPECT/CMR using comparable cut-off MBF. (orig.)

  3. Single photons on demand

    International Nuclear Information System (INIS)

    Grangier, P.; Abram, I.

    2004-01-01

    Quantum cryptography and information processing are set to benefit from developments in novel light sources that can emit photons one by one. Quantum mechanics has gained a reputation for making counter-intuitive predictions. But we rarely get the chance to witness these effects directly because, being humans, we are simply too big. Take light, for example. The light sources that are familiar to us, such as those used in lighting and imaging or in CD and DVD players, are so huge that they emit billions and billions of photons. But what if there was a light source that emitted just one photon at a time? Over the past few years, new types of light source that are able to emit photons one by one have been emerging from laboratories around the world. Pulses of light composed of a single photon correspond to power flows in the femtowatt range - a million billion times less than that of a table lamp. The driving force behind the development of these single-photon sources is a range of novel applications that take advantage of the quantum nature of light. Quantum states of superposed and entangled photons could lead the way to guaranteed-secure communication, to information processing with unprecedented speed and efficiency, and to new schemes for quantum teleportation. (U.K.)

  4. Assessment of skull base involvement in nasopharyngeal carcinoma: comparisons of single-photon emission tomography with planar bone scintigraphy and X-ray computed tomography

    International Nuclear Information System (INIS)

    Lee Chianghsuan; Wang Peiwen; Chen Hueyong; Lui Chunchung; Su Chihying

    1995-01-01

    The diagnostic contribution of single-photon emission tomography (SPET) to the detection of bone lesions of the skull base was explored in 200 patients with nasopharyngeal carcinoma (NPC). Comparison of SPET with planar bone scintigraphy showed that SPET improved the contrast and better defined the lesions in 107 out of the 200 patients. Comparison of SPET with X-ray computed tomography (CT) showed that SPET did not miss the lesions detected by CT while CT missed 49% of the lesions detected by SPET. The only false-positive lesion with SPET was detected in the mastoid bone. SPET detected skull base lesions in all of the 35 patients with cranial nerve involvement, while CT missed eight and planar bone scintigraphy missed four. The findings suggest that SPET should be included in the routine check-up examinations of patients with NPC. (orig.)

  5. Delayed decrease in hemispheric cerebral blood flow during Wada test demonstrated by 99mTc-HMPAO single photon emission computer tomography

    International Nuclear Information System (INIS)

    Ryding, E.; Sjoeholm, H.; Skeidsvoll, H.; Elmqvist, D.

    1989-01-01

    We describe how brain regions with a flow (and metabolism) decrease can be visualized after an injection of short-acting barbiturate in one of the internal carotid arteries during a Wada test. An intravenous administration of 99mTc-HMPAO was used to mark the relative flow distribution. The 99mTc-HMPAO distribution in the brain was recorded three-dimensionally about 1 h later, by means of a single photon emission computer tomograph. We show that the timing of the intravenous 99mTc-HMPAO administration during the Wada test is important for the visualization of the low-flow regions. The administration of the tracer substance should be delayed at least 30 s after the first signs of the barbiturate effect. The rCBF decrease in the barbiturate-injected cerebral hemisphere was associated with a simultaneous decrease in the contralateral, pharmacologically not directly affected, cerebellar hemisphere (crossed cerebellar diaschisis). (author)

  6. A case of temporal lobe epilepsy with improvement of clinical symptoms and single photon emission computed tomography findings after treatment with clonazepam.

    Science.gov (United States)

    Ide, M; Mizukami, K; Suzuki, T; Shiraishi, H

    2000-10-01

    A 26-year-old female presented psychomotor seizures, deja vu and amnestic syndrome after meningitis at the age of 14 years. Repeated electroencephalograms (EEG) demonstrated occasional spikes localized in the right temporal region in addition to a considerable amount of theta waves mainly in the right fronto-temporal region. Single photon emission computed tomography (SPECT) showed a marked hypoperfusion corresponding to the region in which the EEG showed abnormal findings, although magnetic resonance imaging (MRI) demonstrated no abnormal findings associated with the clinical features. Treatment with clonazepam in addition to sodium valproate resulted in a remarkable improvement of clinical symptoms (i.e. psychomotor seizures and deja vu), as well as of the EEG and SPECT findings. The present study suggests that SPECT is a useful method not only to determine the localization of regions associated with temporal lobe epilepsy but also to evaluate the effect of treatment in temporal lobe epilepsy.

  7. Regional cerebral blood flow assessed by single photon emission computed tomography (SPECT) in dogs with congenital portosystemic shunt and hepatic encephalopathy.

    Science.gov (United States)

    Or, Matan; Peremans, Kathelijne; Martlé, Valentine; Vandermeulen, Eva; Bosmans, Tim; Devriendt, Nausikaa; de Rooster, Hilde

    2017-02-01

    Regional cerebral blood flow (rCBF) in eight dogs with congenital portosystemic shunt (PSS) and hepatic encephalopathy (HE) was compared with rCBF in eight healthy control dogs using single photon emission computed tomography (SPECT) with a 99m technetium-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) tracer. SPECT scans were abnormal in all PSS dogs. Compared to the control group, rCBF in PSS dogs was significantly decreased in the temporal lobes and increased in the subcortical (thalamic and striatal) area. Brain perfusion imaging alterations observed in the dogs with PSS and HE are similar to those in human patients with HE. These findings suggest that dogs with HE and PSS have altered perfusion of mainly the subcortical and the temporal regions of the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Evaluation of the system performance and clinical images of the single photon emission computed tomography for head using ring arranged detector

    International Nuclear Information System (INIS)

    Ejiri, Kazutaka; Toyama, Hiroshi; Kato, Yukihiko; Narita, Takae; Takeshita, Gen; Takeuchi, Akira; Koga, Sukehiko

    1988-01-01

    To evaluate the system performance, several preoperational fundamental tests of single photon emission computed tomography (SPECT) were carried out. Spatial resolutions (FWHM) measured with the point-spread functions of a 99m Tc line source were 12.5 mm with a high resolution (HR) collimator and 17.2 mm with a high sensitivity (HS) collimator respectively. Slice thicknesses (FWHM) obtained from the profile curves of slice images were 17.5 mm (HR) and 29.0 mm (HS) at the center of rotation. System sensitivities were 5.4 kcps/slice (HR) and 27.8 kcps/slice (HS). Uniformities calculated from the SPECT images of a pool phantom were 4.7 % (HR) and 2.7 % (HS) at the condition of 3000 kcounts to be acquired. SPECT images of the HEADTOME SET-031 were considered very useful to diagnose the cerebrovascular disease. (author)

  9. Usefulness of technetium-99m tetrofosmin single-photon emission computed tomography for short-term risk stratification in patients with acute chest pain in the emergency room

    International Nuclear Information System (INIS)

    Kawahito, Michitomo; Kondo, Makoto; Abe, Yoshiteru

    2003-01-01

    High-risk patients with acute coronary syndrome are difficult to distinguish from low-risk patients with chest pain in the emergency room. Technetium-99 m ( 99m Tc) tetrofosmin single-photon emission computed tomography (SPECT) was investigated to exclude high-risk patients with chest pain in the emergency room. 99m Tc-tetrofosmin SPECT was evaluated using a four-point scoring system in 228 patients (144 men, 84 women, mean age 68±12 years) with chest pain. Negative was defined as the myocardial segments with a defect score (DS) of 99m Tc-tetrofosmin; no significance (NS)), 84.9% (NS) and 60.4% (p 99m Tc-tetrofosmin SPECT is a useful method to exclude high-risk patients among patients with chest pain in the emergency room. (author)

  10. In vivo measurement of haloperidol affinity to dopamine D2/D3 receptors by [123I]IBZM and single photon emission computed tomography

    DEFF Research Database (Denmark)

    Videbaek, C; Toska, K; Friberg, L

    2001-01-01

    This study examines the feasibility of a steady-state bolus-integration method with the dopamine D2/D3 receptor single photon emission computer tomography (SPECT) tracer, [123I]IBZM, for determination of in vivo affinity of haloperidol. The nonspecific binding of [123I]IBZM was examined in the rat...... brain by infusion of haloperidol to plasma levels approximately 100 times the Kd level in man. In humans, Kd for haloperidol binding was measured in four healthy volunteers that were examined twice: once with partial dopamine D2/D3 receptor blockade obtained by a scheduled infusion of unlabeled...... haloperidol (0.7 mg total dosage), and once in an unblocked state. Blood sampling and SPECT were performed intermittently during 6 hours after intravenous [123I]IBZM bolus injection. Plasma [123I]IBZM was determined by octane extraction. Plasma haloperidol was determined by a radioimmunoassay, and plasma...

  11. Post meningitis subdural hygroma: anatomical and functional evaluation with 99mTc-ethylene cysteine dimer single photon emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. 99m Tc-ethylene cysteine dimer ( 99m Tc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cerebral hypoperfusion. If 99m Tc-ECD SPECT/CT is integrated into management of these patients, it can help in decision making with respect to conservative versus surgical management. (author)

  12. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) in schizophrenia and atypical psychosis

    International Nuclear Information System (INIS)

    Suga, Hidemichi; Hayashi, Takuji; Mitsugi, Ohara

    1994-01-01

    As a basis for possible classification of schinzophrenic psychoses into schizophrenia and atypical psychosis, we studied the brain functional differences among 16 schizophrenic patients, 16 atypical psychosis patients and 16 healthy volunteers by single photon emission computed tomography (SPECT) using N-isopropyl-p-[ 123 I] iodoamphetamine. As a result, schizophrenics showed hypofrontality. On the other hand, atypical psychotics had no such hypofrontality but showed a reduced uptake rate in the right thalamic region. No influence of sex, duration of illness and medication was confirmed by the findings. The results suggest that schizophrenics might have some lesions in the frontal regions, whereas atypical psychotics might have no such lesions, but dysfunction in the right thalamic region. Consequently, the SPECT findings as least indicate possibly different etiologies for schizophrenia and atypical psychosis. (author)

  13. Dipyridamole thallium-201 single-photon emission computed tomography for prediction of perioperative cardiac events in patients with arteriosclerosis obliterans undergoing vascular surgery

    International Nuclear Information System (INIS)

    Ziyang, Huang; Komori, Sadayoshi; Sawanobori, Takao

    1998-01-01

    The aim of the study was to determine whether or not dipyridamole thallium-201 single-photon emission computed tomography ( 201 Tl-SPECT) has significant additive value for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) undergoing vascular surgery. Routine preoperative 201 Tl-SPECT was performed in 106 consecutive patients with ASO (age 68±8.9 years; 91 men and 15 women). The frequency of reversible defects in a clinical high-risk group (n=44) was significantly higher than in a low-risk group (n=62; 55% vs 24%, p 201 Tl-SPECT data to clinical risk-stratified patients with ASO allows better prediction of perioperative cardiac events. (author)

  14. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  15. Perirolandic hypoperfusion on single-photon emission computed tomography in term infants with perinatal asphyxia: comparison with MRI and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, C.S.; Kim, D.I.; Lee, S.; Yoon, P.H.; Jeon, T.J.; Lee, J.D. [Department of Diagnostic Radiology, Yonsei University College of Medicine, Seoul (Korea); Ryu, Y.H. [Department of Diagnostic Radiology, Yonsei University College of Medicine, Seoul (Korea); Department of Nuclear Medicine, Ghil Medical Center, Gachon Medical School, Inchon (Korea); Park, C.I. [Department of Rehabilitation Medicine, Yonsei University College of Medicine, Seoul (Korea)

    2000-12-01

    We describe the findings on single-photon emission computed tomography (SPECT) in patients with perinatal asphyxia at term, with perirolandic cortico-subcortical changes on MRI, and to correlate them with clinical features. SPECT of 7 patients was obtained after injection of 185-370 MBq of Tc-99m-ECD (ethyl cysteinate dimer). The patients had spastic quadriplegia (7/7) with perinatal asphyxia (6/7) at term (7/7). The results were correlated with the MRI findings. Hypoperfusion of the perirolandic cortex was clearly seen on SPECT in all patients, even in two with subtle changes on MRI. SPECT demonstrated a more extensive area of involvement than MRI, notably in the cerebellum (in 4), the thalamus (in 7) and basal ganglia (in 5), where MRI failed to show any abnormalities. (orig.)

  16. Perirolandic hypoperfusion on single-photon emission computed tomography in term infants with perinatal asphyxia: comparison with MRI and clinical findings

    International Nuclear Information System (INIS)

    Yoon, C.S.; Kim, D.I.; Lee, S.; Yoon, P.H.; Jeon, T.J.; Lee, J.D.; Ryu, Y.H.; Park, C.I.

    2000-01-01

    We describe the findings on single-photon emission computed tomography (SPECT) in patients with perinatal asphyxia at term, with perirolandic cortico-subcortical changes on MRI, and to correlate them with clinical features. SPECT of 7 patients was obtained after injection of 185-370 MBq of Tc-99m-ECD (ethyl cysteinate dimer). The patients had spastic quadriplegia (7/7) with perinatal asphyxia (6/7) at term (7/7). The results were correlated with the MRI findings. Hypoperfusion of the perirolandic cortex was clearly seen on SPECT in all patients, even in two with subtle changes on MRI. SPECT demonstrated a more extensive area of involvement than MRI, notably in the cerebellum (in 4), the thalamus (in 7) and basal ganglia (in 5), where MRI failed to show any abnormalities. (orig.)

  17. Acute effect of electroconvulsive therapy on brain perfusion assessed by Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, D.; Ivancevic, D. (Department of Nuclear Medicine, University Hospital Rebro, Zagreb (Yugoslavia)); Medved, V. (Psychiatric Clinic, University Hospital Rebro, Zagreb (Yugoslavia))

    1989-01-01

    Regional cerebral blood flow (rCBF) was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography in 11 patients undergoing electroconvulsive therapy (ECT). The patients suffered from major depressive disorder (n=8) or schizoaffective disorders (n=3). rCBF was measured under general anesthesia 3 days prior to the ECT treatment and coinciding with the ECT stimualtion. ECT caused a redistribution of the tracers uptake. The uptake became more pronounced in frontal parts of the brain and in the basal ganglia than in posterior parts of the cortex, and the thalamus. This selective effect of ECT on rCBF may be related to catecholaminergic projections to anterior parts of the brain. (author).

  18. Acute effect of electroconvulsive therapy on brain perfusion assessed by Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, D.; Ivancevic, D.; Medved, V.

    1989-01-01

    Regional cerebral blood flow (rCBF) was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography in 11 patients undergoing electroconvulsive therapy (ECT). The patients suffered from major depressive disorder (n=8) or schizoaffective disorders (n=3). rCBF was measured under general anesthesia 3 days prior to the ECT treatment and coinciding with the ECT stimualtion. ECT caused a redistribution of the tracers uptake. The uptake became more pronounced in frontal parts of the brain and in the basal ganglia than in posterior parts of the cortex, and the thalamus. This selective effect of ECT on rCBF may be related to catecholaminergic projections to anterior parts of the brain. (author)

  19. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi; Hayashi, Takuji; Mitsugi, Ohara [Aichi Medical Univ., Nagakute (Japan)

    1994-12-01

    As a basis for possible classification of schinzophrenic psychoses into schizophrenia and atypical psychosis, we studied the brain functional differences among 16 schizophrenic patients, 16 atypical psychosis patients and 16 healthy volunteers by single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I] iodoamphetamine. As a result, schizophrenics showed hypofrontality. On the other hand, atypical psychotics had no such hypofrontality but showed a reduced uptake rate in the right thalamic region. No influence of sex, duration of illness and medication was confirmed by the findings. The results suggest that schizophrenics might have some lesions in the frontal regions, whereas atypical psychotics might have no such lesions, but dysfunction in the right thalamic region. Consequently, the SPECT findings as least indicate possibly different etiologies for schizophrenia and atypical psychosis. (author).

  20. Variable uptake feature of focal nodular hyperplasia in Tc-99m phytate hepatic scintigraphy/single-photon emission computed tomography-A parametric analysis.

    Science.gov (United States)

    Hsu, Yu-Ling; Chen, Yu-Wen; Lin, Chia-Yang; Lai, Yun-Chang; Chen, Shinn-Cherng; Lin, Zu-Yau

    2015-12-01

    Tc-99m phytate hepatic scintigraphy remains the standard method for evaluating the functional features of Kupffer cells. In this study, we demonstrate the variable uptake feature of focal nodular hyperplasia (FNH) in Tc-99m phytate scintigraphy. We reviewed all patients who underwent Tc-99m phytate hepatic scintigraphy between 2008 and 2012 in Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. Cases with FNH were diagnosed on the basis of pathology or at least one or more prior imaging with a periodic clinical follow-up. All patients received a standard protocol of dynamic flow study and planar and Tc-99m phytate single-photon emission computed tomography (E. CAM; Siemens). The correlation of variable nodular radioactivity with parameters such as tumor size and localization was analyzed. In total, 15 lesions of 14 patients in the clinic were diagnosed as FNH. The tumor size was approximately 2.9-7.4 cm (mean size 4.6 cm). Four lesions were larger than 5 cm. The major anatomic distribution was in the right hepatic lobe (10 lesions), particularly in the superior segments (7 lesions). Tc-99m phytate single-photon emission computed tomography imaging for determining the functional features of Kupffer cells included cool/cold (8 lesions), isoradioactive/warm (6 lesions), and hot (1 lesion) patterns of uptake. We did not observe any statistically significant correlation between variable nodular radioactivity and tumor size (p=0.68) or localization (p=0.04). Herein, we demonstrate the variable uptake feature of FNH in Tc-99m phytate scintigraphy. In small FNH tumors (< 5 cm), increased or equal uptake still provided specificity for the differential diagnosis of hepatic solid tumors. Copyright © 2015. Published by Elsevier Taiwan.

  1. Comparison of Tc-99m-sestamibi-F-18-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress Tc-99m-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    De Boer, J; Slart, RHJA; Blanksma, Paulus; Willemsen, ATM; Jager, PL; Paans, AMJ; Vaalburg, W; Piers, DA

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-99m-sestamibi (Tc-99m-MIBI) and metabolism using F-18-fluorodeoxyglucose (F-18-FDG) in a single study. The prerequisite is that

  2. Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    den Boer, Johan; Slart, R H J A; Blanksma, P K; Willemsen, Antonius; Jager, P L; Paans, A M J; Vaalburg, W; Piers, D A

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-sestamibi ( Tc-MIBI) and metabolism using F-fluorodeoxyglucose ( F-FDG) in a single study. The prerequisite is that the Tc-MIBI

  3. 99mTc-Hexamethyl Propyleneamine Oxime Brain Perfusion Single Photon Emission Computed Tomography in Characterization of Dementia: An Initial Experience in Indian Clinical Practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Sinha, Gaurav Kumar; Neogi, Rajarshi; Thukral, Ramesh Kumar

    2014-01-01

    There is a growing health burden in developing countries due to recent trends of increasing incidence of neurodegenerative diseases. To reduce the healthcare cost and effective management of dementia illness, early diagnosis, accurate differentiation and their progression assessment is becoming crucially important. We are utilizing 99m Tc-d, l-hexamethyl propyleneamine oxime (HMPAO) brain perfusion single photon emission computed tomography (SPECT) to characterize dementia on the basis of perfusion patterns and observed significant improvement in their management. Eleven patients (median age of 60 years range of 53-83 years) with clinical suspicion of dementia underwent 99m Tc-HMPAO brain perfusion SPECT. SPECT-computed tomography acquisition done, data are reconstructed, reviewed in three view and further processed in “neurogam” to get voxel based analysis and the comparison with age based normal database and surface mapping. Final diagnosis was done with clinical correlation. Four patients are diagnosed as Alzheimer's disease, two as frontotemporal dementia, one as dementia of Lewy bodies, two as vascular dementia and two as pseudodementia. All imaging findings are well-correlated with clinical background. Brain perfusion SPECT with HMPAO was very helpful to us in characterizing the patients of dementia by its perfusion pattern

  4. Quantitative thallium-201 single-photon emission computed tomography during maximal pharmacologic coronary vasodilation with adenosine for assessing coronary artery disease

    International Nuclear Information System (INIS)

    Nishimura, S.; Mahmarian, J.J.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    The diagnostic value of maximal pharmacologic coronary vasodilation with intravenously administered adenosine in conjunction with thallium-201 single-photon emission computed tomography (SPECT) for detection of coronary artery disease was investigated in 101 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps of the thallium-201 distribution. Significant coronary artery disease, defined as greater than 50% luminal diameter stenosis, was present in 70 patients. The sensitivity for detecting patients with coronary artery disease using quantitative analysis was 87% in the total group, 82% in patients without myocardial infarction and 96% in those with prior myocardial infarction; the specificity was 90%. The sensitivity for diagnosing coronary artery disease in patients without infarction with single-, double-and triple-vessel disease was 76%, 86% and 90%, respectively. All individual stenoses were identified in 68% of patients with double-vessel disease and in 65% of those with triple-vessel disease. The extent of the perfusion defects, as quantified by polar maps, was directly related to the extent of coronary artery disease. In conclusion, quantitative thallium-201 SPECT during adenosine infusion has high sensitivity and specificity for diagnosing the presence of coronary artery disease, localizing the anatomic site of coronary stenosis and identifying the majority of affected vascular regions in patients with multivessel involvement

  5. Usefulness of acute myocardial infarct size and localization using Tc-99m-pyrophosphate and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujisue, Ryu; Ohyanagi, Mitsumasa; Todo, Yasuhiro

    1985-01-01

    Tc-99m-Pyrophosphate(PYP)myocardial emission computed tomography(ECT) was performed following standard planar imaging in 45 patients(pts) with acute myocardial infarction(AMI). All of them had clinical, electrocardiographic and enzymatic evidence of AMI. The planar imaging and ECT imaging were interpreted independently by two observers who had no knowledge of the clinical findings. 10 pts(22.2 %), who showed diffuse uptake on planar imaging, revealed focal uptake on ECT imaging without cardiac blood pool imaging. And there is no disagreement as to interpretation of the infarct location by two observers on ECT imaging. We conclude that ECT imaging with Tc-99m-PYP increases interobserver agreement in the diagnosis and localization of AMI and may lead to more accurate localization and sizing of AMI, espesically in cases of diffuse cardiac activity on planar imaging. (author)

  6. Use of fuzzy edge single-photon emission computed tomography analysis in definite Alzheimer's disease - a retrospective study

    International Nuclear Information System (INIS)

    Rusina, Robert; Kukal, Jaromír; Bělíček, Tomáš; Buncová, Marie; Matěj, Radoslav

    2010-01-01

    Definite Alzheimer's disease (AD) requires neuropathological confirmation. Single-photon emission computed tomography (SPECT) may enhance diagnostic accuracy, but due to restricted sensitivity and specificity, the role of SPECT is largely limited with regard to this purpose. We propose a new method of SPECT data analysis. The method is based on a combination of parietal lobe selection (as regions-of-interest (ROI)), 3D fuzzy edge detection, and 3D watershed transformation. We applied the algorithm to three-dimensional SPECT images of human brains and compared the number of watershed regions inside the ROI between AD patients and controls. The Student's two-sample t-test was used for testing domain number equity in both groups. AD patients had a significantly reduced number of watershed regions compared to controls (p < 0.01). A sensitivity of 94.1% and specificity of 80% was obtained with a threshold value of 57.11 for the watershed domain number. The narrowing of the SPECT analysis to parietal regions leads to a substantial increase in both sensitivity and specificity. Our non-invasive, relatively low-cost, and easy method can contribute to a more precise diagnosis of AD

  7. 99mTc-DMSA renal uptake in urological diseases measured from renal tomographic images using single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Oishi, Yukihiko; Tashiro, Kazuya; Kishimoto, Koichi; Wada, Tetsuro; Torii, Shinichiro; Yoshigoe, Fukuo; Machida, Toyohei; Yamada, Hideo; Toyama, Hinako.

    1987-01-01

    To determine renal function, 99m Tc-DMSA renal uptake was measured from renal tomographic images obtained by single photon emission computed tomography (SPECT). A total of 77 tests was conducted on 73 patients with various diseases in the kidneys and urinary tract to determine renal uptake. The correlation coefficient(r) between total renal volume and total renal uptake was 0.3509 and that between renal volume and uptake of 143 kidneys was 0.5433. In 62 patients whose creatinine clearance could be measured, the correlation coefficient between creatinine clearance and total renal volume was 0.2352, and that between creatinine clearance and total renal uptake was 0.8854, that is, creatinine clearance correlated well with renal uptake. Renal volume and uptake determined in 10 normal male and 10 normal female adults were 220 ml and 26.8 % for the right kidney and 239 ml and 27.6 % for the left kidney for the males and 206 ml and 26.4 % (right) and 237 ml and 27.9 % (left) for the females. This method, which requires no blood or urine collection, is very useful as an individual kidney function test to evaluate individual kidney function and to understand kidney function before and after operation in patients with renal and urinary diseases. (author)

  8. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  9. Can Dynamic Susceptibility Contrast Magnetic Resonance Imaging Replace Single-Photon Emission Computed Tomography in the Diagnosis of Patients with Alzheimer's Disease? A Pilot Study

    International Nuclear Information System (INIS)

    Cavallin, L.; Danielsson, R.; Oeksengard, A.R.; Wahlund, L.O.; Julin, P.; Frank, A.; Engman, E.L.; Svensson, L.; Kristoffersen Wiberg, M.

    2006-01-01

    Purpose: To compare single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer's disease (AD). Material and Methods: Twenty-four patients, eight with AD, 10 with MCI, and six controls were investigated with SPECT using 99m Tc-hexamethylpropyleneamine oxime (HMPAO) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with gadobutrol. Three observers performed a visual interpretation of the SPECT and MR images using a four-point visual scale. Results: SPECT was superior to DSC-MRI in differentiating normal from pathological. All three observers showed statistically significant results in discriminating between the control group, AD, and MCI by SPECT, with a P value of 0.0006, 0.04, and 0.01 for each observer. The statistical results were not significant for MR (P values 0.8, 0.1, and 0.2, respectively). Conclusion: DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer's disease. Several patient- and method-related improvements should be made before this method can be recommended for clinical practice

  10. Can Dynamic Susceptibility Contrast Magnetic Resonance Imaging Replace Single-Photon Emission Computed Tomography in the Diagnosis of Patients with Alzheimer's Disease? A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Cavallin, L.; Danielsson, R.; Oeksengard, A.R.; Wahlund, L.O.; Julin, P.; Frank, A.; Engman, E.L.; Svensson, L.; Kristoffersen Wiberg, M. [Karolinska Univ. Hospital, Stockholm (Sweden). Div. of Radiology

    2006-11-15

    Purpose: To compare single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer's disease (AD). Material and Methods: Twenty-four patients, eight with AD, 10 with MCI, and six controls were investigated with SPECT using {sup 99m}Tc-hexamethylpropyleneamine oxime (HMPAO) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with gadobutrol. Three observers performed a visual interpretation of the SPECT and MR images using a four-point visual scale. Results: SPECT was superior to DSC-MRI in differentiating normal from pathological. All three observers showed statistically significant results in discriminating between the control group, AD, and MCI by SPECT, with a P value of 0.0006, 0.04, and 0.01 for each observer. The statistical results were not significant for MR (P values 0.8, 0.1, and 0.2, respectively). Conclusion: DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer's disease. Several patient- and method-related improvements should be made before this method can be recommended for clinical practice.

  11. Correlation between angiogenesis and reduction ratio measured using 201Tl chloride single photon emission computed tomography in patients with oral cavity squamous cell carcinoma

    International Nuclear Information System (INIS)

    Suzuki, Aya; Togawa, Takashi; Omura, Ken

    2004-01-01

    The aim of this study is to examine the correlation between tumor angiogenesis and response to preoperative radiotherapy evaluated using 201 Tl single photon emission computed tomography (Tl SPECT) in oral cavity squamous cell carcinoma (SCC). Tl SPECTs before and after preoperative radiotherapy were obtained from 11 patients diagnosed with SCC in oral cavity. Regions of interest were set around the tumor and scalp respectively, and the ratio of mean counts in the tumor to those in the scalp was calculated (T/N). Immunohistochemical staining for investigating microvessel density of pre-treatment biopsy specimen was performed using CD31 monoclonal antibody. We compared microvessel density with semi-quantitative parameters obtained using Tl SPECT (T/N at pre- an post-treatment, reduction ratio) and prognosis. The subgroup with higher microvessel density showed a significantly higher reduction ratio than the one with lower microvessel density. Regarding prognosis, the subgroup with locoregional recurrent disease exhibited a significantly higher microvessel density than the one without recurrence. In SCC of the oral cavity, there was a significant correlation between microvessel density and response to preoperative radiotherapy. Namely, it was revealed that change of 201 Tl uptake after preoperative radiotherapy correlated with tumor angiogenesis of oral cavity SCC. (author)

  12. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    International Nuclear Information System (INIS)

    Yamada, Kazutaka; Tsuzura, Shigenobu; Matsuda, Hiroshi.

    1995-01-01

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[ 123 I]-iodoamphetamine ( 123 I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author)

  13. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Kazutaka; Tsuzura, Shigenobu [Metropolitan Medical Center of the Severely Handicapped, Fuchu, Tokyo (Japan); Matsuda, Hiroshi

    1995-07-01

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I]-iodoamphetamine ({sup 123}I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author).

  14. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-β-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Shimoyama, Katsuya

    1999-01-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using 123 I-β-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and 201 thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  15. Assessment of the brain areas perfused by superselective intra-arterial chemotherapy using single photon emission computed tomography with technetium-99m-hexamethyl-propyleneamine oxime. Technical note

    Energy Technology Data Exchange (ETDEWEB)

    Namba, Hiroki; Iwadate, Yasuo; Saegusa, Takashi; Sueyoshi, Kanji [Chiba Cancer Center Hospital (Japan); Kobayashi, Shigeki; Sato, Akira; Watanabe, Yoshiro

    1994-12-01

    The brain areas perfused by superselective intra-arterial (i.a.) chemotherapy were assessed using single photon emission computed tomography (SPECT) with technetium-99m-hexamethyl-propyleneamine oxime ({sup 99m}Tc-HMPAO). A superselective catheter was introduced into the anterior, middle, or posterior cerebral artery of patients with malignant glioma for i.a. chemotherapy. {sup 99m}Tc-HMPAO was subsequently injected via the same catheter used for chemotherapy, and a higher dose of {sup 99m}Tc-HMPAO was injected intravenously to obtain adequate background brain images. Comparison of the SPECT images with magnetic resonance images could confirm complete perfusion of the tumor tissue. In two patients with malignant glioma, regions of interest were selected in the peritumoral brain area and a reference brain area, and the radioactivity was measured. The concentration of {sup 99m}Tc-HMPAO was about 50 times higher in tissue perfused by superselective injection into anterior or middle cerebral artery compared to intravenous injection. {sup 99m}Tc-HMPAO SPECT is readily available in many institutions and the information provided is useful for planning more effective and safe i.a. chemotherapy. (author).

  16. Comparative study of thallium-201 single-photon emission computed tomography and electrocardiography in Duchenne and other types of muscular dystrophy

    International Nuclear Information System (INIS)

    Yamamoto, S.; Matsushima, H.; Suzuki, A.; Sotobata, I.; Indo, T.; Matsuoka, Y.

    1988-01-01

    Single-photon emission computed tomography (SPECT) using thallium-201 was compared with 12-lead electrocardiography (ECG) in patients with Duchenne (29), facioscapulohumeral (7), limb-girdle (6) and myotonic (5) dystrophies, by dividing the left ventricular (LV) wall into 5 segments. SPECT showed thallium defects (37 patients, mostly in the posteroapical wall), malrotation (23), apical aneurysm (5) and dilatation (7). ECG showed abnormal QRS (36 patients), particularly as a posterolateral pattern (13). Both methods of assessment were normal in only 7 patients. The Duchenne type frequently showed both a thallium defect (particularly in the posteroapical wall) and an abnormal QRS (predominantly in the posterolateral wall); the 3 other types showed abnormalities over the 5 LV wall segments in both tests. The percent of agreement between the 2 tests was 64, 66, 70, 72 and 72 for the lateral, apical, anteroseptal, posterior and inferior walls, respectively. The 2 tests were discordant in 31% of the LV wall, with SPECT (+) but ECG (-) in 21% (mostly in the apicoinferior wall) and SPECT (-) but ECG (+) in 10% (mostly in the lateral wall). Some patients showed large SPECT hypoperfusion despite minimal electrocardiographic changes. ECG thus appeared to underestimate LV fibrosis and to reflect posteroapical rather than posterolateral dystrophy in its posterolateral QRS pattern. In this disease, extensive SPECT hypoperfusion was also shown, irrespective of clinical subtype and skeletal involvement

  17. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  18. Detection of hemodynamic impairment using magnetic resonance angiography in patients with internal carotid artery stenoocclusive disease. Comparison with quantitative brain perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Hirooka, Ryonoshin; Ogasawara, Kuniaki

    2008-01-01

    Cerebrovascular reactivity (CVR) to acetazolamideis a key parameter in determining the severity of hemodynamic impairment in patients with major cerebral artery occlusive disease. The aim of the present study is to validate the accuracy of magnetic resonance angiography (MRA) for detecting hemodynamic impairment by correlating detectability of the middle cerebral artery obtained by MRA with CVR measured by single-photon emission computed tomography (SPECT) in patients with internal carotid artery (ICA) occlusive disease. Ninety-four patients with chronic ICA occlusion underwent single slab three-dimensional time-of-flight MRA and SPECT. SPECT-CVR was calculated by measured cerebral blood flow before and after acetazolamide challenge. CVR was significantly lower in patients without detection of any portion (M1, M2 or M3) of the MCA than in those with detection of all portions. When SPECT-CVR lower than the mean- 2 standard deviation (SD) obtained in normal subjects was defined as reduced and the SPECT-CVR was assumed as the true determinant of hemodynamic impairment, MRA provided 92% sensitivity and 73% specificity, with 96% negative predictive value for detecting patients with reduced CVR. The present MRA method is effective for the identification of patients with hemodynamic impairment. (author)

  19. Change in size, shape and radiocolloid uptake of the alcoholic liver during alcohol withdrawal, as demonstrated by single photon emission computed tomography

    International Nuclear Information System (INIS)

    Blomquist, L.; Yansen Wang; Jacobsson, H.; Kimiaei, S.

    1994-01-01

    The volume of the total liver and separate right and left lobes was studied before and after 1 week of alcohol withdrawal in 16 consecutive alcoholics by means of single photon emission computed tomography after intravenous injection of 99 Tc m -human albumin colloid; the relative tissue distribution of radioactivity was also followed. The left liver lobe increased in volume more than the right lobe during drinking and decreased more rapidly after alcohol withdrawal. Median volume reductions during 1 week of alcohol withdrawal were: total liver 12%, left lob 26%, and right lobe 8%, indicating that half of the reduction to values of a control group was achieved during this first week. The volume of the right but not of the left lobe was significantly correlated to body size in alcoholics and in controls. The left lobe had a lower capacity to concentrate the radiocolloid than the right lobe in alcoholics and in controls. The liver/spleen, liver/bone marrow and liver/background radioactivity concentration ratios in the alcoholics increased during alcohol withdrawal We conclude that heavy drinking causes both an increased total liver volume and a change in liver shape, with a relatively more enlarged left right lobe, as well as a decreased capacity to concentrate radiocolloid. These changes are rapidly reversible during abstinence from alcohol. (au) (26 refs.)

  20. Initial clinical experiences with dopamine D2 receptor imaging by means of 2'-iodospiperone and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Saji, Hideo; Iwasaki, Yasushi

    1995-01-01

    Dopamine D 2 receptor imaging was performed with 123 I labeled 2'-iodospiperone (2'-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson's disease, 2 with parkinsonism, 1 with Wilson's disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of 123 I-2'-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson's disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson's disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2'-ISP can be used for SPECT imaging of D 2 dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author)

  1. Assessment of right ventricular function using gated blood pool single photon emission computed tomography in inferior myocardial infarction with or without hemodynamically significant right ventricular infarction

    International Nuclear Information System (INIS)

    Takahashi, Masaharu

    1992-01-01

    Right ventricular function was assessed using gated blood pool single photon emission computed tomography (GSPECT) in 10 normal subjects and 14 patients with inferior myocardial infarction. Three-dimensional backbround subtraction was achieved by applying an optimal cut off level. The patient group consisted of 6 patients with definite hemodynamic abnormalities indicative of right ventricular infarction (RVI) and 8 other patients with significant obstructive lesion at the proximal portion of right coronary artery without obvious hemodynamic signs of RVI. Right ventricular regional wall motion abnormalities were demonstrated on GSPECT functional images and the indices of right ventricular function (i.e the right ventricular ejection fraction (RVEF), the right ventricular peak ejection rate (RVPER) and the right ventricular peak filling rate (RVPFR)) were significantly reduced in the patient group, not only in the patients with definite RVI but also in those without hemodynamic signs of RVI, even in the absence of definite hemodynamic signs, when the proximal portion of right coronary artery is obstructed. It is concluded that GSPECT is reliable for the assessment of right ventricular function and regional wall motion, and is also useful for the diagnosis of RVI. (author)

  2. Rapid and efficient radiosynthesis of [{sup 123}I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Pimlott, Sally L. [Department of Clinical Physics, West of Scotland Radionuclide Dispensary, Western Infirmary, G11 6NT Glasgow (United Kingdom)], E-mail: s.pimlott@clinmed.gla.ac.uk; Stevenson, Louise [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom); Wyper, David J. [Institute of Neurological Sciences, Southern General Hospital, G51 4TF Glasgow (United Kingdom); Sutherland, Andrew [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom)

    2008-07-15

    Introduction: [{sup 123}I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [{sup 123}I]I-PK11195 in order to develop a rapid and efficient method that obtains [{sup 123}I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. Methods: The synthesis of [{sup 123}I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Results: Electrophilic iododestannylation produced [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [{sup 123}I]I-PK11195. Conclusions: [{sup 123}I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved.

  3. Rapid and efficient radiosynthesis of [123I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors

    International Nuclear Information System (INIS)

    Pimlott, Sally L.; Stevenson, Louise; Wyper, David J.; Sutherland, Andrew

    2008-01-01

    Introduction: [ 123 I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [ 123 I]I-PK11195 in order to develop a rapid and efficient method that obtains [ 123 I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. Methods: The synthesis of [ 123 I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Results: Electrophilic iododestannylation produced [ 123 I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [ 123 I]I-PK11195. Conclusions: [ 123 I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [ 123 I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved

  4. Comparative study of dobutamine stress echocardiography and dual single-photon emission computed tomography (Thallium-201 and I-123 BMIPP) for assessing myocardial viability after acute myocardial infarction

    International Nuclear Information System (INIS)

    Yasugi, Naoko; Hiroki, Tadayuki

    2002-01-01

    Discordance between the 123 I-labelled 15-iodophenyl-3-R, S-methyl pentadecanoic acid (BMIPP) and 201 Tl findings may indicate myocardial viability (MV). This study compared dobutamine stress echocardiography (DSE) and single-photon emission computed tomography (SPECT) using the dual tracers for assessment of MV and prediction of functional recovery after acute myocardial infarction (AMI). DSE and dual SPECT were studied in 35 patients after AMI, of whom 28 underwent percutaneous coronary intervention in the acute stage. Dual SPECT was performed to compare the defect score of BMIPP and 201 Tl. The left ventricular wall motion score (WMS) was estimated during DSE and 6 months later to assess functional recovery of the infarct area. The rate of agreement of MV between dual SPECT and DSE was 89% (p 201 Tl were significantly smaller in patients with functional recovery than in those without. Assessment of MV using DSE concords with the results of dual SPECT in the early stage of AMI. DSE may have a higher predictive value for long-term functional recovery at the infarct area. However, a finding of positive MV by dual SPECT, without functional recovery, may indicate residual stenosis of the infarct-related artery, although the number of cases was small. Combined assessment by dual SPECT and DSE may be useful for detecting MV and jeopardized myocardium. Furthermore, the results suggest that functional recovery of dysfunctional myocardium may depend on the size of the infarct and risk area. (author)

  5. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    Science.gov (United States)

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, Parea (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.

  6. Unmasking the mechanism of diffuse left ventricular wall motion abnormality in ischemic cardiomyopathy by resting-redistribution thallium-201 single photon computed tomography

    International Nuclear Information System (INIS)

    Namura, Hiroyuki; Yamabe, Hiroshi; Kakimoto, Tetsuya; Hashimoto, Yasunori; Yasaka, Yoshinori; Yoshida, Hiroaki; Itoh, Kazushi; Yokoyama, Mitsuhiro; Maeda, Kazumi.

    1992-01-01

    The study population comprised patients with ischemic cardiomyopathy (ICM) who had left ventricular wall motion (LVWM) abnormality in 5 or more segments (n=9), those with extensive myocardial infarction (EMI) having LVWM abnormality in 4 or less segments (n=12), and those with dilated left ventricle (DLV) having LVWM abnormality in all 7 segments (n=9). Defect scores (DS), obtained by initial and delayed Tl-201 myocardial single photon emission computed tomography at rest, were visually assessed to compare perfusion patterns in the three patient groups. The group of ICM patients had greater defect segments (DSeg) and % redistribution (Rd) index than the other two groups, although there was no difference in the number of angiographically proven infarct-related coronary vessels between EMI and ICM. In the group of ICM patients, there was inverse correlation not only between left ventricular ejection fraction and the sum of DS but also between left ventricular enddiastolic volume index and both the sum of DSeg and % Rd index. The group of DLV patients had small sum of DSeg and redistribution, compared with the other two groups. Although diffuse LVWM abnormality, as observed in the group of ICM patients, was considered attributable to potential decrease of coronary perfusion shown as defect on SPECT images, it did not always coincide with findings of coronary angiography. Both DSeg and redistribution phenomenon on SPECT images seemed to have the ability to evaluate the severity of ICM, as well as to differentiate ICM, EMI, and DLV. (N.K.)

  7. Electrocardiograph-gated single photon emission computed tomography radionuclide angiography presents good interstudy reproducibility for the quantification of global systolic right ventricular function.

    Science.gov (United States)

    Daou, Doumit; Coaguila, Carlos; Vilain, Didier

    2007-05-01

    Electrocardiograph-gated single photon emission computed tomography (SPECT) radionuclide angiography provides accurate measurement of right ventricular ejection fraction and end-diastolic and end-systolic volumes. In this study, we report the interstudy precision and reliability of SPECT radionuclide angiography for the measurement of global systolic right ventricular function using two, three-dimensional volume processing methods (SPECT-QBS, SPECT-35%). These were compared with equilibrium planar radionuclide angiography. Ten patients with chronic coronary artery disease having two SPECT and planar radionuclide angiography acquisitions were included. For the right ventricular ejection fraction, end-diastolic volume and end-systolic volume, the interstudy precision and reliability were better with SPECT-35% than with SPECT-QBS. The sample sizes needed to objectify a change in right ventricular volumes or ejection fraction were lower with SPECT-35% than with SPECT-QBS. The interstudy precision and reliability of SPECT-35% and SPECT-QBS for the right ventricle were better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography on the same population. SPECT-35% and SPECT-QBS present good interstudy precision and reliability for right ventricular function, with the results favouring the use of SPECT-35%. The results are better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography. They need to be confirmed in a larger population.

  8. The effect of the superficial temporal to middle cerebral artery bypass based on the data of motor activation single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Morimoto, Tetsuya; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    We evaluated and analyzed the effect of the superficial temporal to middle cerebral artery (STA-MCA) bypass for the pure motor function in the ischemic cerebrovascular diseases (CVDs) using the motor activation single photon emission computed tomography (SPECT). Motor activation SPECT was performed on the 25 cases with ischemic CVD treated with STA-MCA bypass. Motor activation SPECT studies using the finger opposition task on the affected side were performed before surgery, at 1 month, and at 3 months after the bypass. The result of the motor activation SPECT was expressed as negative and positive by the visual inspection. During the follow-up period (mean; 2.2 years), there has been no recurrent or worsening clinical symptom. Before bypass, 10 cases were positive in the motor activation SPECT. The other 15 cases were negative. At one month after bypass, 14 cases were positive in the motor activation SPECT. At three months after bypass, 23 cases were positive in the motor activation SPECT. Twenty-two cases showed the improvement of the resting CBF. STA-MCA bypass is useful for pure motor function in the ischemic CVDs based on the motor activation SPECT coupling with their clinical symptoms. (author)

  9. The effect of the superficial temporal to middle cerebral artery bypass based on the data of motor activation single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Morimoto, Tetsuya; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    We evaluated and analyzed the effect of the superficial temporal to middle cerebral artery (STA-MCA) bypass for the pure motor function in the ischemic cerebrovascular diseases (CVDs) using the motor activation single photon emission computed tomography (SPECT). Motor activation SPECT was performed on the 25 cases with ischemic CVD treated with STA-MCA bypass. Motor activation SPECT studies using the finger opposition task on the affected side were performed before surgery, at 1 month, and at 3 months after the bypass. The result of the motor activation SPECT was expressed as negative and positive by the visual inspection. During the follow-up period (mean; 2.2 years), there has been no recurrent or worsening clinical symptom. Before bypass, 10 cases were positive in the motor activation SPECT. The other 15 cases were negative. At one month after bypass, 14 cases were positive in the motor activation SPECT. At three months after bypass, 23 cases were positive in the motor activation SPECT. Twenty-two cases showed the improvement of the resting CBF. STA-MCA bypass is useful for pure motor function in the ischemic CVDs based on the motor activation SPECT coupling with their clinical symptoms. (author)

  10. Monte Carlo Study of the Effect of Collimator Thickness on T-99m Source Response in Single Photon Emission Computed Tomography

    International Nuclear Information System (INIS)

    Islamian, Jalil Pirayesh; Toossi, Mohammad Taghi Bahreyni; Momennezhad, Mahdi; Zakavi, Seyyed Rasoul; Sadeghi, Ramin; Ljungberg, Michael

    2012-01-01

    In single photon emission computed tomography (SPECT), the collimator is a crucial element of the imaging chain and controls the noise resolution tradeoff of the collected data. The current study is an evaluation of the effects of different thicknesses of a low-energy high-resolution (LEHR) collimator on tomographic spatial resolution in SPECT. In the present study, the SIMIND Monte Carlo program was used to simulate a SPECT equipped with an LEHR collimator. A point source of 99m Tc and an acrylic cylindrical Jaszczak phantom, with cold spheres and rods, and a human anthropomorphic torso phantom (4D-NCAT phantom) were used. Simulated planar images and reconstructed tomographic images were evaluated both qualitatively and quantitatively. According to the tabulated calculated detector parameters, contribution of Compton scattering, photoelectric reactions, and also peak to Compton (P/C) area in the obtained energy spectrums (from scanning of the sources with 11 collimator thicknesses, ranging from 2.400 to 2.410 cm), we concluded the thickness of 2.405 cm as the proper LEHR parallel hole collimator thickness. The image quality analyses by structural similarity index (SSIM) algorithm and also by visual inspection showed suitable quality images obtained with a collimator thickness of 2.405 cm. There was a suitable quality and also performance parameters’ analysis results for the projections and reconstructed images prepared with a 2.405 cm LEHR collimator thickness compared with the other collimator thicknesses

  11. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera.

    Science.gov (United States)

    Shiraishi, Shinya; Sakamoto, Fumi; Tsuda, Noriko; Yoshida, Morikatsu; Tomiguchi, Seiji; Utsunomiya, Daisuke; Ogawa, Hisao; Yamashita, Yasuyuki

    2015-01-01

    Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.

  12. Initial clinical experiences with dopamine D{sub 2} receptor imaging by means of 2`-iodospiperone and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Yoshiharu [Fukui Medical Schoool, Matsuoka (Japan). Biomedical Imaging Research Center; Saji, Hideo; Iwasaki, Yasushi [and others

    1995-08-01

    Dopamine D{sub 2} receptor imaging was performed with {sup 123}I labeled 2`-iodospiperone (2`-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson`s disease, 2 with parkinsonism, 1 with Wilson`s disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of {sup 123}I-2`-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson`s disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson`s disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2`-ISP can be used for SPECT imaging of D{sub 2} dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author).

  13. Effect of diltiazem on myocardial infarct size estimated by enzyme release, serial thallium-201 single-photon emission computed tomography and radionuclide angiography

    International Nuclear Information System (INIS)

    Zannad, F.; Amor, M.; Karcher, G.; Maurin, P.; Ethevenot, G.; Sebag, C.; Bertrand, A.; Pernot, C.; Gilgenkrantz, J.M.

    1988-01-01

    Diltiazem is a calcium antagonist with demonstrated experimental cardioprotective effects. Its effects on myocardial infarct size were studied in 34 patients admitted within 6 hours after the first symptoms of acute myocardial infarction. These patients were randomized, double-blind to placebo or diltiazem (10-mg intravenous bolus followed by 15 mg/hr intravenous infusion during 72 hours, followed by 4 X 60 mg during 21 days). Myocardial infarct size was assessed by plasma creatine kinase and creatine kinase-MB indexes, perfusion defect scores using single-photon emission computed tomography with thallium-201 and left ventricular ejection fraction measured by radionuclide angiography. Tomographic and angiographic scanning was performed serially before randomization, after 48 hours and 21 days later. Groups were comparable in terms of age, sex, inclusion time and baseline infarct location and size. Results showed no difference in creatine kinase and creatine kinase-MB data between controls and treated patients, a significant decrease in the perfusion defect scores in the diltiazem group (+0.1 +/- 3.0 placebo vs -2.2 +/- 1.9 diltiazem, p less than 0.02) and a better ejection fraction recovery in the diltiazem group (-4.2 +/- 7.4 placebo vs +7.7 +/- 11.2 diltiazem, p less than 0.05). Myocardial infarct size estimates from perfusion defect scores and enzyme data were closely correlated. These preliminary results suggest that diltiazem may reduce ischemic injury in acute myocardial infarction

  14. Clinical results with beta-methyl-p-(123I)iodophenylpentadecanoic acid, single-photon emission computed tomography in cardiac disease.

    Science.gov (United States)

    Nishimura, T; Uehara, T; Shimonagata, T; Nagata, S; Haze, K

    1994-01-01

    This study was undertaken to evaluate the relationships, between myocardial perfusion and metabolism. Simultaneous beta-methyl-p(123I)iodophenylpentadecanoic acid (123I-BMIPP) and thallium 201 myocardial single-photon emission computed tomography (SPECT) were performed in 25 patients with myocardial infarction (group A) and 16 patients with hypertrophic cardiomyopathy (group B). The severity scores of 123I-BMIPP and 201Tl myocardial SPECT images were evaluated semiquantitatively by segmental analysis. In Group A, dissociations between thallium- and 123I-BMIPP-imaged defects were frequently observed in patients with successful reperfusion compared with those with no reperfusion and those with reinfarction. In four patients with successful reperfusion, repeated 123I-BMIPP and 201Tl myocardial SPECT showed gradual improvement of the 123I-BMIPP severity score compared with the thallium severity score. In group B, dissociations between thallium- and 123I-BMIPP-imaged defects were also demonstrated in hypertrophic myocardium. In addition, nonhypertrophic myocardium also had decreased 123I-BMIPP uptake. In groups A and B, 123I-BMIPP severity scores correlated well with left ventricular function compared with thallium severity scores. These findings indicate that 123I-BMIPP is a suitable agent for the assessment of functional integrity, because left ventricular wall motion is energy dependent and 123I-BMIPP may reflect an aspect of myocardial energy production. This agent may be useful for the early detection and patient management of various heart diseases as an alternative to positron emission tomographic study.

  15. Dynamic 123I-BMIPP single-photon emission computed tomography in patients with congestive heart failure: effect of angiotensin II type-1 receptor blockade.

    Science.gov (United States)

    Takeishi, Yasuchika; Minamihaba, Osamu; Yamauchi, Sou; Arimoto, Takanori; Hirono, Osamu; Takahashi, Hiroki; Akiyama, Hideyuki; Miyamoto, Takuya; Nitobe, Joji; Nozaki, Naoki; Tachibana, Hidetada; Okuyama, Masaki; Fukui, Akio; Kubota, Isao; Okada, Akio; Takahashi, Kazuei

    2004-04-01

    Heart failure is a major and growing public health problem with a high mortality rate. Although recent studies have demonstrated that a variety of metabolic and/or neurohumoral factors are involved in the progression of this syndrome, the precise mechanisms responsible for this complex condition are poorly understood. To examine 123I-beta-methyl-iodophenylpentadecanoic acid (BMIPP) kinetics in the early phase soon after tracer injection in patients with congestive heart failure (CHF), we performed dynamic single-photon emission computed tomography (SPECT). Twenty-six patients with CHF and eight control subjects were examined. The consecutive 15 images of 2-min dynamic SPECT were acquired for 30 min after injection. In the early phase after injection (0-4 min), a significant amount of radioactivity existed in the blood pool. After 6 min, the myocardial 123I-BMIPP image was clear and thus the washout rate of 123I-BMIPP from 6 to 30 min was calculated. The washout rate of 123I-BMIPP from the myocardium was faster in patients with CHF than in the controls (8 +/- 4 vs. -5 +/- 3%, p acid metabolism may represent a new mechanism for beneficial effects of angiotensin II receptor blockade on cardiac function and survival in patients with heart failure. 123I-BMIPP washout in the early phase obtained from dynamic SPECT may be a new marker for evaluating the severity of heart failure and the effects of medical treatment.

  16. Usefulness of dual energy single photon emission computed tomography with 99mTc-pyrophosphate and 201TlCl in diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Shohgase, Takashi; Okita, Kohichi; Sakai, Hiroto; Fukuda, Hiroyuki; Anzai, Teisuke; Yamaguchi, Masashi; Koseki, Yukio; Tsujita, Naoyuki; Itoh, Hideki

    1990-01-01

    The dual energy single photon emission computed tomography (D-SPECT) with 99m Tc-Pyrophosphate and 201 TlCl was evaluated, using Bull's Eye Map representation in 30 patients with acute myocardial infarction. D-SPECT imaging for infarct detection was 100% sensitive. The patients were divided into two groups. One group had an overlap of accumulation of 99m Tc and 201 TlCl in the infarct zone and the other had no overlap. Fifteen of 19 patients (78.9%) in whom reperfusion was successful showed an overlap. Ten of 11 patients in whom reperfusion was unsuccessful showed no overlap. In the patients with successful reperfusion, the group that showed an overlap had a shorter interval between the onset of acute myocardial infarction and the reperfusion of coronary artery than the group that showed no overlap. But one case showed that collateral circulation had an influence on the overlap. In conclusion, using Bull's Eye Map representation, D-SPECT was useful to detect infarct and the overlap of accumulation of 99m Tc and 201 TlCl might be used as an index of early recanalization. (author)

  17. Normal stress-only myocardial single photon emission computed tomography predicts good outcome in patients with coronary artery stenoses between 40 and 70.

    Science.gov (United States)

    Jiang, Zhixin; Liu, Yangqing; Xin, Chaofan; Zhou, Yanli; Wang, Cheng; Zhao, Zhongqiang; Li, Chunxiang; Li, Dianfu

    2016-09-01

    Normal stress myocardial single photon emission computed tomography (SPECT) usually indicates good physiologic function of all coronary lesions, and also indicates a good outcome. We hypothesize that it can still predict good outcome in patients with coronary stenoses between 40 and 70%. A group of patients who underwent stress myocardial SPECT after coronary angiography were consecutively recruited in our center. Patients were eligible if they had one or more coronary stenoses between 40 and 70%. Patients with coronary stenoses greater than 50% diameter of left main or greater than 70% diameter of nonleft main epicardial vessels, and left ventricular ejection fraction less than 50% were excluded. The outcome was defined as major adverse events, including cardiac death, nonfatal myocardial infarction, and revascularization. Patients' survival curves were constructed accorded to the method of Kaplan and Meier and compared using the log-rank test. A study cohort of 77 patients was enrolled. According to the summed stress score, 43 patients were assigned to the perfusion defect group and 34 patients were assigned to the perfusion normal group. The follow-up duration was 6.4±0.3 years. In the perfusion normal group, only one of 34 (2.9%) patients developed major adverse events. In the perfusion defect group, six of 43 (14%) developed major adverse events, P-value of 0.041. It is safe to defer a percutaneous coronary intervention in patients with coronary stenoses between 40 and 70% and normal stress myocardial SPECT.

  18. Clinical value of iodine-123 beta-methyliodophenyl pentadecanoic acid (BMIPP) myocardial single photon emission computed tomography for predicting cardiac death among patients with chronic heart failure

    International Nuclear Information System (INIS)

    Sasaki, Ryu; Usui, Takashi; Mitani, Isao

    2003-01-01

    In the present study, the effectiveness of 123 I-β-methyliodophenyl pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) for predicting cardiac death of patients with chronic heart failure was evaluated. Abnormalities of fatty acid metabolism are found in patients with chronic heart failure and BMIPP was developed as a tracer for scintigraphic assessment of myocardial fatty acid utilization. The study group comprised 74 patients with chronic heart failure with a left ventricular ejection fraction (LVEF) 201 Tl SPECT and BMIPP SPECT. The uptake of tracer was scored semiquantitatively from 0 (normal) to 4 (defect) in 20 segments and a total defect score (TDS) for all 20 segments was calculated. On planar images the mediastinum to heart count ratio (H/M) was calculated for the BMIPP and Tl studies, and the H/M BMIPP :H/M Tl (H/M BMIPP divided by H/M Tl ) was also calculated. The mean follow-up period was 660 days and there were 17 cases of cardiac death. Multivariate analysis identified H/M BMIPP :H/M Tl (p BMIPP :H/M Tl was situated to the left relative to LVEF. Analysis of the myocardial metabolism by BMIPP SPECT can predict the high-risk patients with chronic heart failure. (author)

  19. Diagnostic Performance of a Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography System With Low-Dose Technetium-99m as Assessed by Fractional Flow Reserve.

    Science.gov (United States)

    Chikamori, Taishiro; Hida, Satoshi; Tanaka, Nobuhiro; Igarashi, Yuko; Yamashita, Jun; Shiba, Chie; Murata, Naotaka; Hoshino, Kou; Hokama, Yohei; Yamashina, Akira

    2016-04-25

    Although stress single-photon emission computed tomography (SPECT) using a cadmium-zinc-telluride (CZT) camera facilitates radiation dose reduction, only a few studies have evaluated its diagnostic accuracy in Japanese patients by applying fractional flow reserve (FFR) measurements. We prospectively evaluated 102 consecutive patients with suspected or known coronary artery disease with a low-dose stress/rest protocol ((99m)Tc radiotracer 185/370 MBq) using CZT SPECT. Within 3 months, coronary angiography was performed and a significant stenosis was defined as ≥90% diameter narrowing on visual estimation, or as a lesion of <90% and ≥ 50% stenosis with FFR ≤0.80. To detect individual coronary stenosis, the respective sensitivity, specificity, and accuracy were 86%, 75%, and 82% for left anterior descending artery stenosis, 76%, 81%, and 79% for left circumflex artery stenosis, and 87%, 92%, and 90% for right coronary artery stenosis. When limited to 92 intermediate stenotic lesions in which FFR was measured, stress SPECT showed 77% sensitivity, 91% specificity, and 84% accuracy, whereas the diagnostic value decreased to 52% sensitivity, 68% specificity, and 58% accuracy based only on visual estimation of ≥75% diameter narrowing. CZT SPECT demonstrated a good diagnostic yield in detecting hemodynamically significant coronary stenoses as assessed by FFR, even when using a low-dose (99m)Tc protocol with an effective dose ≤5 mSv. (Circ J 2016; 80: 1217-1224).

  20. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[123I]iodoamphetamine (123I-IMP) in schizophrenia and atypical psychosis

    International Nuclear Information System (INIS)

    Suga, Hidemichi

    1993-01-01

    Sixteen schizophrenic patients, 16 atypical psychosis patients, and 16 healthy volunteers were subjected to single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP). The basal ganglia region was in particular examined not only in transverse sections, but in coronal sections. Schizophrenics showed significantly decreased uptake rates in the bilateral frontal regions and increased uptakes in the bilateral basal ganglia. On the other hand, atypical psychotics had a reduced uptake rate only in the right thalamic region, compared to the controls. The increased uptake rates in the basal ganglia were associated with auditory hallucination, but gender difference, duration of illness and dose of neuroleptics had no influence on these SPECT findings. The results suggest that schizophrenics might have some lesions in the frontal area of the brain, whereas atypical psychotics might have no lesion in the frontal region but dysfunction in the right thalamic region. Subsequently, using only SPECT findings, all the cases were divided by cluster analysis into 4 groups and a residue group. Schizophrenics distributed mainly in the 2 groups that have lesion in the frontal regions. Atypical psychotics distributed principally in the other 2 groups that have alterations in the bilateral thalamic region. The present study suggests that schizophrenia and atypical psychosis might have different etiologies. (author)

  1. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi (Aichi Medical Univ., Nagakute (Japan))

    1993-05-01

    Sixteen schizophrenic patients, 16 atypical psychosis patients, and 16 healthy volunteers were subjected to single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP). The basal ganglia region was in particular examined not only in transverse sections, but in coronal sections. Schizophrenics showed significantly decreased uptake rates in the bilateral frontal regions and increased uptakes in the bilateral basal ganglia. On the other hand, atypical psychotics had a reduced uptake rate only in the right thalamic region, compared to the controls. The increased uptake rates in the basal ganglia were associated with auditory hallucination, but gender difference, duration of illness and dose of neuroleptics had no influence on these SPECT findings. The results suggest that schizophrenics might have some lesions in the frontal area of the brain, whereas atypical psychotics might have no lesion in the frontal region but dysfunction in the right thalamic region. Subsequently, using only SPECT findings, all the cases were divided by cluster analysis into 4 groups and a residue group. Schizophrenics distributed mainly in the 2 groups that have lesion in the frontal regions. Atypical psychotics distributed principally in the other 2 groups that have alterations in the bilateral thalamic region. The present study suggests that schizophrenia and atypical psychosis might have different etiologies. (author).

  2. A study of cerebral hemodynamics in various cerebrovascular disorders by means of rCBF measurement with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Harano, Hideyuki

    1987-01-01

    Using single photon emission computed tomography (SPECT) with Xe-133 inhalation method, regional cerebral blood flow (rCBF) was measured for the purpose of analyzing the pathophysiology of various cerebrovascular disorders. Included in this series were 38 normal volunteers (N), 72 patients with ischemic cerebrovascular disease (ICD), 16 with subarachnoid hemorrhage (SAH), 9 with arteriovenous malformation (AVM), 6 with Moyamoya disease (MD), and 4 with hypertensive intracerebral hematoma (HIH). In the N group, rCBF was independent of sex and laterality. Increased rCBF was observed in the frontal region, as compared with other regions. A significantly increased rCBF was observed in the thirties decade of life; the difference in rCBF was, however, not statistically significant above the age of 30 years. In the ICD group, rCBF decreased in association with severer disorder. In cases of severe disorder, a significantly decreased rCBF was observed in the whole area, as compared with the control group. SPECT allowed early detection of decreased rCBF due to vaso-spasm in the SAH group. The groups of AVM, MD, and HIH showed decreased rCBF in the surrounding areas of the lesions. (Namekawa, K.)

  3. Iodine-123 metaiodobenzylguanidine scintigraphy and iodine-123 ioflupane single photon emission computed tomography in Lewy body diseases: complementary or alternative techniques?

    Science.gov (United States)

    Treglia, Giorgio; Cason, Ernesto; Cortelli, Pietro; Gabellini, Anna; Liguori, Rocco; Bagnato, Antonio; Giordano, Alessandro; Fagioli, Giorgio

    2014-01-01

    To compare myocardial sympathetic imaging using (123)I-Metaiodobenzylguanidine (MIBG) scintigraphy and striatal dopaminergic imaging using (123)I-Ioflupane (FP-CIT) single photon emission computed tomography (SPECT) in patients with suspected Lewy body diseases (LBD). Ninety-nine patients who performed both methods within 2 months for differential diagnosis between Parkinson's disease (PD) and other parkinsonism (n = 68) or between dementia with Lewy bodies (DLB) and other dementia (n = 31) were enrolled. Sensitivity, specificity, accuracy, positive and negative predictive values of both methods were calculated. For (123) I-MIBG scintigraphy, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 83%, 79%, 82%, 86%, and 76%, respectively. For (123)I-FP-CIT SPECT, the overall sensitivity, specificity, accuracy, positive and negative predictive values in LBD were 93%, 41%, 73%, 71%, and 80%, respectively. There was a statistically significant difference between these two methods in patients without LBD, but not in patients with LBD. LBD usually present both myocardial sympathetic and striatal dopaminergic impairments. (123)I-FP-CIT SPECT presents high sensitivity in the diagnosis of LBD; (123)I-MIBG scintigraphy may have a complementary role in differential diagnosis between PD and other parkinsonism. These scintigraphic methods showed similar diagnostic accuracy in differential diagnosis between DLB and other dementia. Copyright © 2012 by the American Society of Neuroimaging.

  4. Reproducibility and quantitativity of oblique-angle reconstruction in single photon emission computed tomography using Tl-201 myocardial phantom

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Nanbu, Ichiro; Seki, Hiroyasu

    1984-01-01

    This study was carried out in order to evaluate reproducibility and quantitativity of oblique-angle reconstruction of myocardial phantom SPECT. Myocardial phantom with transmural and subendcardial defects, and off-axis phantom with wall thickness changing continuously from 0 to 23 mm were used. Sixty projection data in every 6 0 were aquired using dual-camera (ZLC) with high resolution collimators connected to Scintipac-2400 computer system. Oblique-angle reconstructed images were obtained by indicating the long axis of the phantom manually in the transaxial and vertical long axial tomograms. Reproducibility and quantitativity were evaluated by creating circumferential profile (CFP) of the finally reconstructed short axial images. Inter- and intra-operater reproducibility of relative counting ratio were less than 6.7% (C.V.) and 3.3% (C.V.), respectively. Both inter- and intraoperater reproducibility of absolute counts were better than that of counting ratio (less than 5.1% (C.V.) and 2.9% (C.V.), respectively). Variation of defect location in the reconstructed image and between the slices were less than 1 sampling interval of CFP (6 0 ) and 0.6 slice, respectively. Quantitativity of counts in the reconstructed images was poor in the transmulal defect, but was fair in the subendocardial defect. Counting ratio was greatly affected by wall thickness. Temporal quantitatibity or linearity of the counts in sequential SPECTs was good in non-defect area, especially when wall thickness was greater than 70% (16 mm) of maximum. In conclusion, three-dimensional oblique-angle reconstruction in Tl-201 myocardial SPECT could be applicable to relative and temporal quantitation of local myocardial activity other than defect area for the quantitative evaluation of Tl-201 myocardial wash-out. (J.P.N.)

  5. Sestamibi technetium-99m brain single-photon emission computed tomography to identify recurrent glioma in adults: 201 studies.

    Science.gov (United States)

    Le Jeune, Florence Prigent; Dubois, François; Blond, Serge; Steinling, Marc

    2006-04-01

    In the follow-up of treated gliomas, CT and MRI can often not differentiate radionecrosis from recurrent tumor. The aim of this study was to assess the interest of functional imaging with (99m)Tc-MIBI SPECT in a large series of 201 examinations. MIBI SPECT were performed in 81 patients treated for brain gliomas. A MIBI uptake index was computed as the ratio of counts in the lesion to counts in the controlateral region. SPECT was compared to stereotactic biopsy in 14 cases, or in the others cases to imaging evolution or clinical course at 6 months after the last tomoscintigraphy Two hundred and one tomoscintigraphies were performed. One hundred and two scans were true positive, 82 scans were true negative. Six scans were false positive (corresponding to 3 patients): 2 patients with an inflammatory reaction after radiosurgery, 1 with no explanation up to now. Eleven scans were false negative (5 patients): 1 patient with a deep peri-ventricular lesion, 2 patients with no contrast enhancement on MRI, 2 patients with a temporal tumor. The sensitivity for tumor recurrence was 90%, specificity 91.5% and accuracy 90.5%. We studied separately low and high grade glioma: sensitivity for tumor recurrence was respectively 91% and 89%, specificity 100% and 83% and accuracy 95% and 87%. MIBI SPECT allowed the diagnose of anaplasic degenerence of low grade sometimes earlier than clinical (5 cases) or MRI signs (7 cases). Our results confirm the usefullness of MIBI SPECT in the follow-up of treated gliomas for the differential diagnosis between radiation necrosis and tumor recurrence.

  6. Computed tomography in dementia of Alzheimer type; Comparative study in each stage and comparison to single photon emission computed tomography with N-isopropyl-p-( sup 123 I) iodoamphetamine

    Energy Technology Data Exchange (ETDEWEB)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki [Toyama Medical and Pharmaceutical Univ., Toyama (Japan); and others

    1990-05-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.).

  7. Dystrophic calcification in muscles of legs in calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly, and telangiectasia syndrome: Accurate evaluation of the extent with 99mTc-methylene diphosphonate single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Chakraborty, Partha Sarathi; Karunanithi, Sellam; Dhull, Varun Singh; Kumar, Kunal; Tripathi, Madhavi

    2015-01-01

    We present the case of a 35-year-old man with calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly and telangiectasia variant scleroderma who presented with dysphagia, Raynaud's phenomenon and calf pain. 99m Tc-methylene diphosphonate bone scintigraphy was performed to identify the extent of the calcification. It revealed extensive dystrophic calcification in the left thigh and bilateral legs which was involving the muscles and was well-delineated on single photon emission computed tomography/computed tomography. Calcinosis in scleroderma usually involves the skin but can be found in deeper periarticular tissues. Myopathy is associated with a poor prognosis

  8. Approaches to single photon detection

    International Nuclear Information System (INIS)

    Thew, R.T.; Curtz, N.; Eraerds, P.; Walenta, N.; Gautier, J.-D.; Koller, E.; Zhang, J.; Gisin, N.; Zbinden, H.

    2009-01-01

    We present recent results on our development of single photon detectors, including: gated and free-running InGaAs/InP avalanche photodiodes (APDs); hybrid detection systems based on sum-frequency generation (SFG) and Si APDs-SFG-Si APDs; and SSPDs (superconducting single photon detectors), for telecom wavelengths; as well as SiPM (Silicon photomultiplier) detectors operating in the visible regime.

  9. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  10. Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction. Comparison with three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Lipiec, P.; Wejner-Mik, P.; Krzeminska-Pakula, M.; Kapusta, A.; Kasprzak, J.D.; Kusmierek, J.; Plachcinska, A.; Szuminski, R.

    2008-01-01

    Parameters of left ventricular systolic function directly influence the management of patients with suspected coronary artery disease (CAD). Quantitative gated single-photon emission computed tomography (QGS; Cedars-Sinai Medical Center, Los Angeles, CA, USA) allows the computation of left ventricular ejection fraction (LVEF) from myocardial perfusion imaging studies which are frequently performed on patients with suspected CAD. Three-dimensional (3D) echocardiography is considered to be the echocardiographic ''gold standard'' for the quantification of LVEF. We sought to compare QGS with 3D echocardiography in the evaluation of EF in patients with suspected CAD. Ninety-one consecutive patients with suspected CAD, scheduled for coronary angiography, underwent rest electrocardiographic-gated technetium-99m methoxyisobutylisonitrile SPECT (G-SPECT) with measurement of LVEF by QGS and transthoracic 3D echocardiography with off-line measurement of LVEF (Tomtec 4D LV Analysis 1.1). The diagnosis of CAD was based on coronary angiography, performed on every patient. Nine patients were excluded from the analysis owing to unsuitability for 3D echocardiography (8 patients) or G-SPECT (1 patient). In the remaining group of 82 patients, 71 (87%) had significant CAD, 34 (42%) had a history of myocardial infarction, and 50 (61%) had perfusion defects at rest G-SPECT images. The mean LVEF measured by QGS and 3D echocardiography was 53±13% and 53±10%, respectively. The mean difference in LVEF between 3D echocardiography and QGS was 0.1±6.0% (P=0.87), and the correlation between the values obtained by both methods was high (r=0.88, P< 0.001). The largest discrepancies were observed in patients with small ventricular volumes. In patients undergoing diagnostic work-up for CAD, the measurement of LVEF by QGS algorithm provides high correlation and satisfactory agreement with the results of reference ultrasound method- 3D echocardiography. (author)

  11. Optimization of helical acquisition parameters to preserve uniformity of mouse whole body using multipinhole collimator in single-photon emission computed tomography

    Directory of Open Access Journals (Sweden)

    Naoyuki Ukon

    Full Text Available Focusing on whole-body uniformity in small-animal single-photon emission computed tomography (SPECT, we examined the optimal helical acquisition parameters using five-pinhole collimators for mouse imaging. SPECT images of an 80-mm-long cylindrical phantom with 99mTc solution were acquired using an Inveon multimodality imaging platform. The bed travels used in this study were 0, 30, 60, 90 and 120 mm, and the numbers of revolutions traversed during the SPECT scan were 1.0, 2.0, 3.0, 4.0, 5.0 and 7.0, respectively. Artifacts that degrade uniformity in reconstructed images were conspicuous when the bed travel was smaller than the object length. Regarding the distal-to-center ratio (DCR of SPECT values in the object’s axial direction, the DCR nearest to the ideal ratio of 1.00 was 1.02 in the optimal uniformity with 4.0 revolutions and a bed travel of 120 mm. Moreover, the helical acquisition using these parameters suppressed the formation of artifacts. We proposed the optimal parameters in whole-body helical SPECT; the bed travel was sufficiently larger than the object length; the 4.0 or more revolutions were required for a pitch of approximately 30 mm/revolution. The optimal acquisition parameters in SPECT to preserve uniformity would contribute to the accurate quantification of whole-body biodistribution. Keywords: Helical acquisition, Multipinhole collimator, Computed tomography, SPECT

  12. Generation of Fourier-transform-limited heralded single photons

    International Nuclear Information System (INIS)

    U'Ren, Alfred B.; Jeronimo-Moreno, Yasser; Garcia-Gracia, Hipolito

    2007-01-01

    In this paper we study the spectral (temporal) properties of heralded single photon wave packets, triggered by the detection of an idler photon in the process of parametric down conversion. The generated single photons are studied within the framework of the chronocyclic Wigner function, from which the single photon spectral width and temporal duration can be computed. We derive specific conditions on the two-photon joint spectral amplitude which result in both pure and Fourier-transform-limited heralded single photons. Likewise, we present specific source geometries which lead to the fulfillment of these conditions and show that one of these geometries leads, for a given pump bandwidth, to the temporally shortest possible heralded single photon wave packets

  13. Assessment of ischemic heart disease by dipyridamole stress electrocardiographic gated myocardial single photon emission computed tomography with technetium-99m tetrofosmin

    International Nuclear Information System (INIS)

    Kanna, Masahiko; Mitani, Isao; Nakamaru, Masashi; Shibuya, Ken; Takeda, Kazuyoshi; Asahina, Shigeru; Kitamura, Yutaka; Higuma, Kikuhiko; Ishii, Masao

    1998-01-01

    Simultaneous assessment of stress perfusion and rest function is possible with gated single photon emission computed tomography (SPECT) using stress injected technetium-99m ( 99m Tc) tetrofosmin (TF). The feasibility of dipyridamole stress electrocardiographic gated myocardial SPECT (GSPECT) with TF was examined as an alternative to conventional stress/rest imaging. Fifty-one patients underwent stress GSPECT. 740 MBq of TF was administered 3 min after dipyridamole infusion. GSPECT acquisition was performed one hour after the injection. Additional rest SPECT was performed on another day only in patients with abnormal perfusion on stress images. Perfusion and thickening were analyzed visually on 17 segments of the left ventricle. Percentage of wall thickening (%WT) was also calculated in 17 segments of the polar map. Thirty-two of 51 patients (63%) had normal stress perfusion and normal rest thickening. Nineteen of 51 patients (37%) had abnormal perfusion on stress images. Among 157 abnormal perfusion segments of the 19 patients, 139 segments (89%) had thickening and the rest (11%) had no thickening. %WT was higher in the reversible segments with or without thickening. There was better agreement for the identification of normal segments and the presence of reversibility between stress GSPECT and the conventional stress/rest study in patients without previous myocardial infarction than in those with previous myocardial infarction (89% vs 79%). These results suggest that stress GSPECT may substitute for conventional stress/rest perfusion study in patients without previous myocardial infarction, allowing shorter examination time and lower cost. However, stress GSPECT does not replace the need for rest perfusion study in patients with previous myocardial infarction, because of underestimation of viability, but %WT may eliminate this underestimation. (author)

  14. Synthesis and characterization of radioiodinated MD-230254. A new ligand for potential imaging of monoamine oxidase B activity by single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hirata, Masahiko; Kagawa, Shinya; Yoshimoto, Mitsuyoshi; Ohmomo, Yoshiro

    2002-01-01

    A series of iodinated analogues of MD-230254 was synthesized and evaluated for inhibitory potency and selectivity toward monoamine oxidase B (MAO-B). Among them, 5-[4-(2-iodobenzyloxy)phenyl]-3(cyanoethyl)-1,3,4-oxadiazole-2(3H)one (2-IBPO) was found to have high inhibitory potency and selectivity toward MAO-B (IC 50 =2.0 n M , MAO-A/MAO-B>50000). Analysis of the inhibition kinetics indicated that 2-IBPO acts in a two-step mechanism as a competitive, slow, and tight-binding inhibitor of MAO-B with a Ki value of 2.4 n M and an overall Ki value at an equilibrium of 3.8 n M . The new radioligand for MAO-B, [ 125 I]2-IBPO was conveniently synthesized from a tributylstannyl precursor by an iododestannylation reaction using sodium [ 125 I]iodide and hydrogen peroxide with high radiochemical yield. The in vivo tissue distribution studies of [ 125 I]2-IBPO demonstrated its high initial uptake and prolonged retention in the brain. A selective interaction of [ 125 I]2-IBPO with MAO-B was confirmed by the pretreatment experiment with well known MAO specific inhibitors, l-deprenyl, Ro-16-6491, clorgyline, and Ro-41-1049. These very desirable characteristics of [ 125 I]2-IBPO suggested that a 123 I-labeled counterpart, [ 123 I]2-IBPO, would have great potential in vivo studies of MAO-B in the human brain with single photon emission computed tomography (SPECT). (author)

  15. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  16. [Possibilities of a software-based hybrid single photon emission computed tomography/magnetic resonance imaging in the diagnosis of complicated diabetic foot syndrome].

    Science.gov (United States)

    Zavadovskaya, V D; Zorkal'tsev, M A; Udodov, V D; Zamyshevskaya, M A; Kilina, O Yu; Kurazhov, A P; Popov, K M

    2015-01-01

    To give the results of a software-based hybrid single photon emission computed tomography/magnetic resonance imaging (SPECT/MRI) in detecting osteomyelitis (OM) in patients with diabetic foot syndrome (DFS). Seventy-six patients (35 men and 41 women) (mean age, 59.4 +/- 7.1 years) with type 1 and 2 diabetes mellitus and suspected OM were examined. The investigation enrolled patients with neuropathic (n = 25), ischemic (n = 13), and mixed (n = 38) DFS. All the patients underwent (99m)Tc-HMPAO/ (99m)Tc-technefit labeled leukocyte scintigraphy; magnetic resonance imaging was performed in 30 patients. The results were combined using RView 9.06 software (Colin Studholme). Labeled leukocyte SPECT to Diagnose OM yielded 255 true positive (TP), 38 true negative (TN), 12 false negative (FP), and 1 false negative (FN) results. The accuracy of the technique was 82.9%. The FP results were due to the low resolution of the technique and to the small sizes of the object under study. One FN result was detected in a patient with ischemic DFS because of reduced blood flow. MRI to identify OM in patients with DFS provided 20 TP, 16 TN, 4 FP, and 2 FN results. Its diagnostic accuracy was 85.7%. The relative low specificity of MRI was associated with the presence of FP results due to the complexity of differential diagnosis of bone marrow edema and inflammatory infiltration. Assessing 42 hybrid SPECT/MR-images revealed 21 TP, 17 TN, 3 FP, and I FN results. The diagnostic accuracy was equal to 95.9%. Thus, comparing MRI (90.9% sensitivity and 80.0% specificity), labeled leukocyte scintigraphy (96.2% sensitivity and 76.0% specificity), and hybrid SPECT/MRI (95.5% sensitivity and 85.0% specificity) showed the high diagnostic efficiency of the latter.

  17. Reverse redistribution phenomenon on rest 99mTc-tetrofosmin myocardial single photon emission computed tomography involves impaired left ventricular contraction in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Kurokawa, Kazuyuki; Ohte, Nobuyuki; Miyabe, Hiromichi; Akita, Sachie; Yajima, Kazuhiro; Hayano, Junichiro; Kimura, Genjiro

    2003-01-01

    The purpose of this study was to investigate the clinical significance of the reverse redistribution (RR) phenomenon on technetium-99m ( 99m Tc)-tetrofosmin myocardial single photon emission computed tomography (SPECT) performed at rest. Twenty-five patients underwent myocardial SPECT 3 weeks after the onset of acute myocardial infarction. Myocardial images were acquired at 40 min (early) and 4 h (delayed) after the injection of 740 MBq of 99m Tc-tetrofosmin. The regional myocardial uptake of the tracer in 26 segments of the left ventricular (LV) wall was visually scored from 0 (no activity) to 3 (normal activity), and then the RR was defined as a decrease of more than 1 point in the activity score on the delayed image compared with that on the early image. Regions with an activity score of 3 on both the early and delayed images were defined as normal, and those with a score of 0 or 1 on the early image were considered to have a fixed defect. The regional myocardial 99m Tc-tetrofosmin uptake and washout rate were also quantitatively assessed in each region. In addition, exercise stress electrocardiograph-gated SPECT with 99m Tc-tetrofosmin was performed within 1 week of the rest study, and the percent count increase (%CI) during myocardial contraction in each corresponding region was studied. RR was observed in 18 of the 25 patients. The regional washout rate of 99m Tc-tetrofosmin was significantly higher in the RR regions (45.0±3.8%) than in either the normal regions (36.4±4.1%, p 99m Tc-tetrofosmin SPECT have severely impaired LV wall contraction after exercise. (author)

  18. Correlative single photon emission computed tomography imaging of [{sup 123}I]altropane binding in the rat model of Parkinson's

    Energy Technology Data Exchange (ETDEWEB)

    Gleave, Jacqueline A. [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada); Farncombe, Troy H.; Saab, Chantal [Department of Nuclear Medicine, Hamilton Health Sciences, Hamilton, Ontario, L8N 3Z5 (Canada); Doering, Laurie C., E-mail: doering@mcmaster.ca [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada)

    2011-07-15

    Introduction: This study used the dopamine transporter (DAT) probe, [{sup 123}I]-2{beta}-carbomethoxy-3{beta}-(4-fluorophenyl)-N-(3-iodo-E-allyl)nortropane ([{sup 123}I]altropane), to assess the DAT levels in the 6-hydroxydopamine rat model of Parkinson's disease. We sought to assess if the right to left [{sup 123}I]altropane striatal ratios correlated with dopamine content in the striatum and substantia nigra and with behavioural outcomes. Methods: [{sup 123}I]altropane images taken pre- and postlesion were acquired before and after the transplantation of neural stem/progenitor cells. The images obtained using [{sup 123}I]altropane and single photon emission computed tomography (SPECT) were compared with specific behavioural tests and the dopamine content assessed by high-performance liquid chromatography. Results: [{sup 123}I]altropane binding correlated with the content of dopamine in the striatum; however, [{sup 123}I]altropane binding did not correlate with the dopamine content in the substantia nigra. There was a significant correlation of altropane ratios with the cylinder test and the postural instability test, but not with amphetamine rotations. The low coefficient of determination (r{sup 2}) for these correlations indicated that [{sup 123}I]altropane SPECT was not a good predictor of behavioural outcomes. Conclusion: Our data reveal that [{sup 123}I]altropane predicts the integrity of the striatal dopamine nerve terminals, but does not predict the integrity of the nigrostriatal system. [{sup 123}I]altropane could be a useful marker to measure dopamine content in cell replacement therapies; however, it would not be able to evaluate outcomes for neuroprotective strategies.

  19. Factors affecting accuracy of ventricular volume and ejection fraction measured by gated Tl-201 myocardial perfusion single photon emission computed tomography

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Yang, You Jung; Im, Ki Chun; Hong, Il Ki; Yun, Sung Cheol; Kang, Duk Hyun; Song, Jae Kwan; Moon, Dae Hyuk

    2005-01-01

    Systemic errors in the gated single photon emission computed tomography (SPECT) measurement of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) may occur. We evaluated whether patient-related factors affected the accuracy of EDV, ESV, and EF measured by electrocardiogram-gated Tl-201 SPECT. A total of 518 patients without perfusion defects on Tl-201 SPECT or coronary artery disease were studied. EDV, ESV, and EF were measured from echocardiography and adenosine stress/redistribution gated Tl-201 SPECT using commercially available software packages (QGS and 4D-MSPECT). We identified factors affecting the accuracy of gated SPECT via multiple linear regression analysis of the differences between echocardiography and gated SPECT. Gated SPECT analyzed with QGS underestimated EDV and ESV, and overestimated EF, but 4D-MSPECT overestimated all those values (p<0.001). Independent variables that increased the difference in EDV between echocardiography and gated SPECT were decreasing LV end-diastolic wall thickness, decreasing body surface area, female sex and increasing EDV (p< 0.001). Those for ESV were decreasing LV end-systolic wall thickness, female sex, and decreasing ESV (p<0.001). Increasing end-systolic wall thickness, male sex and decreasing age were independent determinants associated with an increased difference in EF (p< 0.001). Adenosine stress SPECT showed significantly higher EDV and ESV values and a lower EF than did redistribution SPECT (p< 0.001). In determination of EF, QGS demonstrated a smaller bias than did 4D-MSPECT. However, in men with LV hypertrophy, 4D-MSPECT was superior to QGS. Systemic error by gated Tl-201 SPECT is determined by individual patient-characteristics

  20. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  1. Vasodilator stress impairs the left ventricular function obtained with gated single-photon emission computed tomography in patients with known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Odagiri, Keiichi; Uehara, Akihiko; Kurata, Chinori

    2010-01-01

    Transient ischemic dilatation (TID) and post-stress dysfunction of the left ventricle (LV) are important markers of severe coronary artery disease (CAD). To clarify the effects of stressor type on TID and post-stress LV dysfunction, changes in LV measurements were compared between patients with exercise- or vasodilator-induced stress. The 689 patients referred for technetium-99m tetrofosmin myocardial perfusion imaging were included. Patients were stressed with either a vasodilator (n=236) or exercise (n=453). LV measurements were obtained with electrocardiogram (ECG)-gated single photon emission computed tomography (SPECT). LV end-diastolic and end-systolic volume indexes (LVEDVI, LVESVI) increased and LV ejection fraction (LVEF) decreased after stress in the vasodilator-stress group. Vasodilator-stress and the summed difference score (SDS) were independent variables that decreased LVEF after stress. Even in patients without reversible defects, vasodilator-stress impaired LV function. There were no differences in the stress-to-rest ratios of LVEDVI (rEDV) and LVESVI (rESV) among patients with normal myocardial perfusion, fixed defects and reversible defects in the vasodilator-stress group, whereas in the exercise-stress group, rESV was significantly higher in the patients with reversible defects than in those without reversible defects. Within the vasodilator-stress group, neither rEDV nor rESV correlated with the SDS. Vasodilator-stress by itself decreases LVEF after stress. TID should be carefully interpreted when vasodilator-stress is used to detect severe CAD. (author)

  2. Assessment of prognostic value of semiquantitative parameters on gated single photon emission computed tomography myocardial perfusion scintigraphy in a large middle eastern population

    International Nuclear Information System (INIS)

    Chavoshi, Maryam; Fard-Esfahani, Armaghan; Fallahi, Babak; Emami-Ardekani, Alireza; Beiki, Davood; Hassanzadeh-Rad, Arman; Eftekhari, Mohammad

    2005-01-01

    Coronary artery disease is the leading cause of mortality worldwide. The goal of this study is to determine the prognostic value of semiquantitative parameters of electrocardiogram-gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in a large Middle Eastern (Iranian) population. This study was a prospective study including all patients referred to our center for myocardial perfusion scan. The patients were followed annually up to 24 months and their survival information was collected. From 1148 patients, 473 (41.2%) men and 675 (58.8%) women, 40.6% had normal MPI, 13.3% near normal and 46.1% abnormal MPI. After follow-up of 929 patients, 97.4% of patients were alive, and 2.6% succumbed to cardiac deaths. Abnormal ejection fraction was related with cardiac events (P = 0.001), but neither transient ischemic dilation (TID) (P = 0.09) nor lung/heart ratio (P = 0.92) showed such relationship. Association between summed difference score (SDS) and soft cardiac events (P < 0.001) was significant. Summed motion score (SMS) and summed thickening score (STS) showed a significant relation with hard cardiac events, including myocardial infarction and cardiac death (P < 0.001 and P = 0.001, respectively). Totally, risk of all cardiac events was significantly higher in abnormal MPI group than normal group (P < 0.001, 0.02, and 0.025, respectively). No significant relationship was found between TID and total cardiac events (P = 0.478). Semiquantitative variables derived from gated SPECT MPI have independent prognostic value. Rate of total cardiac events is higher in patients with higher summed stress score and SDS. Total and hard cardiac events are higher in upper scores of functional parameters (SMS and STS). Total cardiac events are higher in patients with lower left ventricular ejection fraction

  3. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Vourvouri, E.C.; Poldermans, D.; Sianos, G.; Sozzi, F.B.; Schinkel, A.F.L.; Sutter, J. de; Roelandt, J.R.T.C.; Bax, J.J.; Parcharidis, G.; Valkema, R.

    2001-01-01

    The objective of this study was to perform a head-to-head comparison between two-dimensional (2D) echocardiography and gated single-photon emission computed tomography (SPET) for the evaluation of left ventricular (LV) function and volumes in patients with severe ischaemic LV dysfunction. Thirty-two patients with chronic ischaemic LV dysfunction [mean LV ejection fraction (EF) 25%±6%] were studied with gated SPET and 2D echocardiography. Regional wall motion was evaluated by both modalities and scored by two independent observers using a 16-segment model with a 5-point scoring system (1= normokinesia, 2= mild hypokinesia, 3= severe hypokinesia, 4= akinesia and 5= dyskinesia). LVEF and LV end-diastolic and end-systolic volumes were evaluated by 2D echocardiography using the Simpson's biplane discs method. The same parameters were calculated using quantitative gated SPET software (QGS, Cedars-Sinai Medical Center). The overall agreement between the two imaging modalities for assessment of regional wall motion was 69%. The correlations between gated SPET and 2D echocardiography for the assessment of end-diastolic and end-systolic volumes were excellent (r=0.94, P<0.01, and r=0.96, P<0.01, respectively). The correlation for LVEF was also good (r=0.83, P<0.01). In conclusion: in patients with ischaemic cardiomyopathy, close and significant relations between gated SPET and 2D echocardiography were observed for the assessment of regional and global LV function and LV volumes; gated SPET has the advantage that it provides information on both LV function/dimensions and perfusion. (orig.)

  4. Regional cerebral blood flow changes in schizophrenia and endogenous depression by single photon emission computed tomography (SPECT) using N-isopropyl-p-( sup 123 I)iodoamphetamine (IMP)

    Energy Technology Data Exchange (ETDEWEB)

    Kanaya, Toshinori (Hiroshima Univ. (Japan). School of Medicine)

    1989-06-01

    Regional cerebral blood flows (rCBF) were measured in patients with schizophrenia and endogenous depression by single photon emission computed tomography (SPECT) using N-isopropyl-p-({sup 123}I)iodoamphetamine (IMP). The subjects were 20 patients with shizophrenia, 32 patients with endogenous depression and 20 normal controls. The patients with depression were divided into 3 groups; unmedicated, medicated patients in depressive state, and medicated patients in remited state. The rCBF were calculated by the corticocerebellar ratio (CCR), which was expressed as a ratio of activity per pixel in cortical regions of interest to the activity per pixel in the cerebellum. The results were as follows. In patients with schizophrenia the marked decrease in rCBF in bilateral frontal regions and the lower rCBF in the left than in the right hemisphere were observed. There was no significant correlation between the mean rCBF and BPRS (Brief Psychiatric Rating Scale) in patients with shizophrenia. In patients with depression the decrease in rCBF in overall cerebral regions and the lower rCBF in the left than in the right hemisphere were observed in both groups in depressive state. These changes were normalized in remited state, though there was no significant difference in rCBF between on medication and off medication. There was significantly negative correlation between the mean rCBF and Hamilton Depression Rating Scale in patients with depression. These results support the previously reported 'hypofrontality' and the left hemispheric dysfunction in shizophrenia. In depressive patients the overall cerebral dysfunction was revealed more remarkablly in the left than in the right hemisphere, which was normalized following the improvement of depressive symptoms. Furthermore, it was suggested that the applications of IMP-SPECT could be useful for the diagnosis and research for the cerebral function in mental illness. (author) 59 refs.

  5. The usefulness of dipyridamole thallium-201 single photon emission computed tomography for predicting perioperative cardiac events in patients undergoing non-cardiac vascular surgery

    International Nuclear Information System (INIS)

    Chen, Tao; Kuwabara, Yasuo; Tsutsui, Hiroyuki; Sasaki, Masayuki; Nakagawa, Makoto; Koga, Hirofumi; Kaneko, Kouichirou; Komori, Kimihiro; Masuda, Kouji

    2002-01-01

    The aim of this study was to evaluate the usefulness of dipyridamole Tl-201 myocardium single photon emission computed tomography ( 201 Tl-SPECT) for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) and abdominal aortic aneurysm (AAA) undergoing non-cardiac vascular surgery. Preoperative dipyridamole 201 Tl-SPECT imaging in association with clinical risk assessment was performed in 224 consecutive patients (97 ASO and 127 AAA). The patients were classified into three groups, including low-risk (n=173, 77%), intermediate-risk (n=39, 18%), and high-risk (n=12, 5%) groups according to the clinical risk stratification. The prevalence of reversible Tl-201 defect was significantly higher in the high-risk group than that in the low-risk group (83% vs. 14%, p 201 Tl-SPECT was the only variable to predict perioperative cardiac events by a stepwise logistic regression analysis (odds ratio 7.0, 95% confidence interval 1.7-28.0, p=0.007). It was also a significant predictor of perioperative cardiac events in a subgroup of low risk patients (odds ratio 11.6, 95% confidence interval 2.3-57.4, p=0.004). The sensitivity and specificity of the reversible defect for predicting perioperative cardiac events were 55.6% and 84.8% in all operated patients, and 57.1% and 89.7% in low risk patients, respectively. The preoperative dipyridamole 201 Tl-SPECT was useful for predicting perioperative cardiac events in patients with vascular diseases, even in patients identified as having a low risk based on the clinical risk assessment. (author)

  6. Regional cerebral blood flow changes in schizophrenia and endogenous depression by single photon emission computed tomography (SPECT) using N-isopropyl-p-[123I]iodoamphetamine (IMP)

    International Nuclear Information System (INIS)

    Kanaya, Toshinori

    1989-01-01

    Regional cerebral blood flows (rCBF) were measured in patients with schizophrenia and endogenous depression by single photon emission computed tomography (SPECT) using N-isopropyl-p-[ 123 I]iodoamphetamine (IMP). The subjects were 20 patients with shizophrenia, 32 patients with endogenous depression and 20 normal controls. The patients with depression were divided into 3 groups; unmedicated, medicated patients in depressive state, and medicated patients in remited state. The rCBF were calculated by the corticocerebellar ratio (CCR), which was expressed as a ratio of activity per pixel in cortical regions of interest to the activity per pixel in the cerebellum. The results were as follows. In patients with schizophrenia the marked decrease in rCBF in bilateral frontal regions and the lower rCBF in the left than in the right hemisphere were observed. There was no significant correlation between the mean rCBF and BPRS (Brief Psychiatric Rating Scale) in patients with shizophrenia. In patients with depression the decrease in rCBF in overall cerebral regions and the lower rCBF in the left than in the right hemisphere were observed in both groups in depressive state. These changes were normalized in remited state, though there was no significant difference in rCBF between on medication and off medication. There was significantly negative correlation between the mean rCBF and Hamilton Depression Rating Scale in patients with depression. These results support the previously reported 'hypofrontality' and the left hemispheric dysfunction in shizophrenia. In depressive patients the overall cerebral dysfunction was revealed more remarkablly in the left than in the right hemisphere, which was normalized following the improvement of depressive symptoms. Furthermore, it was suggested that the applications of IMP-SPECT could be useful for the diagnosis and research for the cerebral function in mental illness. (author) 59 refs

  7. Diagnostic imaging of dementia with Lewy bodies by susceptibility-weighted imaging of nigrosomes versus striatal dopamine transporter single-photon emission computed tomography: a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Sato, Kanako; Suzuki, Michimasa; Hori, Masaaki; Kumamaru, Kanako K.; Aoki, Shigeki [Juntendo University Graduate School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Nakatsuka, Tomoya; Inaoka, Tsutomu; Terada, Hitoshi [Toho University Sakura Medical Center, Department of Radiology, Sakura, Sakura (Japan); Sakakibara, Ryuji; Tsuyusaki, Yohei [Toho University Sakura Medical Center, Department of Neurology, Sakura, Sakura (Japan); Takamura, Tomohiro [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan)

    2017-01-15

    The characteristics of dementia with Lewy bodies (DLB), Alzheimer's disease (AD) and amnestic mild cognitive impairment (a-MCI) overlap but require different treatments; therefore, it is important to differentiate these pathologies. Assessment of dopamine uptake in the striatum using dopamine transporter (DaT) single-photon emission computed tomography (SPECT) is the gold standard for diagnosing DLB; however, this modality is expensive, time consuming and involves radiation exposure. Degeneration of the substantia nigra nigrosome-1, which occurs in DLB, but not in AD/a-MCI, can be identified by 3T susceptibility-weighted imaging (SWI). Therefore, the aim of this retrospective observational study was to compare SWI with DaT-SPECT for differentiation of DLB from AD/a-MCI. SWI data were acquired for patients with clinically diagnosed DLB (n = 29), AD (n = 18), a-MCI (n = 13) and healthy controls (n = 26). Images were analysed for nigrosome-1 degeneration. Diagnostic accuracy was evaluated for DLB, AD and a-MCI compared with striatal dopamine uptake using DaT-SPECT. SWI achieved 90% diagnostic accuracy (93% sensitivity, 87% specificity) for the detection of nigrosome-1 degeneration in DLB and not in AD/a-MCI as compared with 88.3% accuracy (93% sensitivity, 84% specificity) using DaT-SPECT. SWI nigrosome-1 evaluation was useful in differentiating DLB from AD/a-MCI, with high accuracy. This less invasive and less expensive method is a potential alternative to DaT-SPECT for the diagnosis of DLB. (orig.)

  8. Behaviors of cost functions in image registration between 201Tl brain tumor single-photon emission computed tomography and magnetic resonance images

    International Nuclear Information System (INIS)

    Soma, Tsutomu; Takaki, Akihiro; Teraoka, Satomi; Ishikawa, Yasushi; Murase, Kenya; Koizumi, Kiyoshi

    2008-01-01

    We studied the behaviors of cost functions in the registration of thallium-201 ( 201 Tl) brain tumor single-photon emission computed tomography (SPECT) and magnetic resonance (MR) images, as the similarity index of image positioning. A marker for image registration [technetium-99m ( 99m Tc) point source] was attached at three sites on the heads of 13 patients with brain tumor, from whom 42 sets of 99m Tc- 201 Tl SPECT (the dual-isotope acquisition) and MR images were obtained. The 201 Tl SPECT and MR images were manually registered according to the markers. From the positions where the two images were registered, the position of the 201 Tl SPECT was moved to examine the behaviors of the three cost functions, i.e., ratio image uniformity (RIU), mutual information (MI), and normalized MI (NMI). The cost functions MI and NMI reached the maximum at positions adjacent to those where the SPECT and MR images were manually registered. As for the accuracy of image registration in terms of the cost functions MI and NMI, on average, the images were accurately registered within 3 deg of rotation around the X-, Y-, and Z-axes, and within 1.5 mm (within 2 pixels), 3 mm (within 3 pixels), and 4 mm (within 1 slice) of translation to the X-, Y-, and Z-axes, respectively. In terms of rotation around the Z-axis, the cost function RIU reached the minimum at positions where the manual registration of the two images was substantially inadequate. The MI and NMI were suitable cost functions in the registration of 201 Tl SPECT and MR images. The behavior of the RIU, in contrast, was unstable, being unsuitable as an index of image registration. (author)

  9. Quantitative estimation of infarct size by simultaneous dual radionuclide single photon emission computed tomography: comparison with peak serum creatine kinase activity

    International Nuclear Information System (INIS)

    Kawaguchi, K.; Sone, T.; Tsuboi, H.; Sassa, H.; Okumura, K.; Hashimoto, H.; Ito, T.; Satake, T.

    1991-01-01

    To test the hypothesis that simultaneous dual energy single photon emission computed tomography (SPECT) with technetium-99m (99mTc) pyrophosphate and thallium-201 (201TI) can provide an accurate estimate of the size of myocardial infarction and to assess the correlation between infarct size and peak serum creatine kinase activity, 165 patients with acute myocardial infarction underwent SPECT 3.2 +/- 1.3 (SD) days after the onset of acute myocardial infarction. In the present study, the difference in the intensity of 99mTc-pyrophosphate accumulation was assumed to be attributable to difference in the volume of infarcted myocardium, and the infarct volume was corrected by the ratio of the myocardial activity to the osseous activity to quantify the intensity of 99mTc-pyrophosphate accumulation. The correlation of measured infarct volume with peak serum creatine kinase activity was significant (r = 0.60, p less than 0.01). There was also a significant linear correlation between the corrected infarct volume and peak serum creatine kinase activity (r = 0.71, p less than 0.01). Subgroup analysis showed a high correlation between corrected volume and peak creatine kinase activity in patients with anterior infarctions (r = 0.75, p less than 0.01) but a poor correlation in patients with inferior or posterior infarctions (r = 0.50, p less than 0.01). In both the early reperfusion and the no reperfusion groups, a good correlation was found between corrected infarct volume and peak serum creatine kinase activity (r = 0.76 and r = 0.76, respectively; p less than 0.01)

  10. Usefulness of lung and right ventricular thallium-201 uptake during single photon emission computed tomography in exercise testing of patients with coronary artery disease

    International Nuclear Information System (INIS)

    Matoh, Fumitaka; Tawarahara, Kei; Mikami, Naoshi

    2005-01-01

    Increased pulmonary or right ventricular 201 Tl uptake during the exercise test has been used as a marker of multivessel coronary artery disease. The most useful method for assessing the severity of coronary artery disease was evaluated among conventional evaluation of single photon emission computed tomography (SPECT), measurement of lung to heart uptake ratio (L/H), and right ventricular to left ventricular uptake ratio (RV/LV) on 201 Tl images during exercise testing. Regions-of-interest (4 x 4 pixels) were placed at the lung and the heart, and L/H was defined as mean lung uptake/mean heart uptake. Correspondingly, regions-of-interest (4 x 4 pixels) were placed at the RV and the LV, and RV/LV was defined as maximum RV uptake/maximum LV uptake. L/H and RV/LV on the initial image were analyzed in 216 patients (angiographically normal coronary arteries: 89, single-vessel disease: 82, multivessel disease: 45). The diagnostic value was evaluated using the receiver operating characteristic curve. All methods showed significantly higher values in patients with multivessel disease than in patients with no coronary artery disease or single-vessel disease. L/H was significantly higher in patients with prior myocardial infarction and RV/LV was significantly higher in patients without infarction. The sensitivity of only conventional SPECT evaluation for multivessel coronary artery disease was low (sensitivity 53%, specificity 94%). However, addition of evaluation of L/H and RV/LV to SPECT improved the sensitivity for multivessel coronary artery disease (sensitivity 93%, specificity 49%). The diagnostic sensitivity for multivessel coronary artery disease was improved by adding L/H and RV/LV to conventional evaluation of exercise 201 Tl SPECT. L/H and RV/LV during exercise 201 Tl imaging may provide additional information regarding the severity of coronary artery disease. (author)

  11. Voxel-Based Correlation between Coregistered Single-Photon Emission Computed Tomography and Dynamic Susceptibility Contrast Magnetic Resonance Imaging in Subjects with Suspected Alzheimer Disease

    International Nuclear Information System (INIS)

    Cavallin, L.; Axelsson, R.; Wahlund, L.O.; Oeksengard, A.R.; Svensson, L.; Juhlin, P.; Wiberg, M. Kristoffersen; Frank, A.

    2008-01-01

    Background: Current diagnosis of Alzheimer disease is made by clinical, neuropsychologic, and neuroimaging assessments. Neuroimaging techniques such as magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) could be valuable in the differential diagnosis of Alzheimer disease, as well as in assessing prognosis. Purpose: To compare SPECT and MRI in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer disease (AD). Material and Methods: 24 patients, eight with AD, 10 with MCI, and six controls, were investigated with SPECT using 99m Tc-hexamethylpropyleneamine oxime (HMPAO, Ceretec; GE Healthcare Ltd., Little Chalsont UK) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a contrast-enhancing gadobutrol formula (Gadovist; Bayer Schering Pharma, Berlin, Germany). Voxel-based correlation between coregistered SPECT and DSC-MR images was calculated. Region-of-interest (ROI) analyses were then performed in 24 different brain areas using brain registration and analysis of SPECT studies (BRASS; Nuclear Diagnostics AB, Stockholm (SE)) on both SPECT and DSC-MRI. Results: Voxel-based correlation between coregistered SPECT and DSC-MR showed a high correlation, with a mean correlation coefficient of 0.94. ROI analyses of 24 regions showed significant differences between the control group and AD patients in 10 regions using SPECT and five regions in DSC-MR. Conclusion: SPECT remains superior to DSC-MRI in differentiating normal from pathological perfusion, and DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer disease

  12. Prediction of 6-year prognosis for cardiac event by thallium-201 single-photon emission computed tomography (SPECT) with treadmill exercise test

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Ohsuzu, Fumitaka; Kosuda, Shigeru; Nakamura, Haruo

    1997-01-01

    To examine thallium-201 single-photon emission computed tomography (SPECT) with a treadmill exercise test can predict the long-term prognosis of patients with coronary artery disease, 95 patients (71 men, 24 women) who underwent a treadmill exercise test with thallium-201 SPECT from April to December 1986 were followed for 6 years. Three short-axis slices at the apical, mid- and basal-level were selected, and each slice was divided into eight segments. Each segment count was assigned a score according to the count range in the slice (score 0, count range 76-100%; 1, 51-75%; 2, 26-50%; 3, 1-25%; 4, 0%) by evaluating the mean value of the slice. The total Tl defect score of each segment in 3 slices was summed (ΣTl defect score). The 'early ΣTl defect score' was the ΣTl defect score 5 min after treadmill exercise, and the 'late ΣTl defect score' was ΣTl defect score measured 4 h after treadmill exercise. Cardiac events occurred in 27 of the 95 patients: cardiac death 3; myocardial infarction 1; percutaneous transluminal angioplasty 16; coronary artery bypass graft 5; congestive heart failure 3. Univariate analysis showed that previous myocardial infarction (p<0.01), exercise work load (p<0.05), early ΣTl defect score (p<0.0l) and late ΣTl defect score (p<0.01) were independent predictors of the prognosis. These results suggest that thallium-201 SPECT with the treadmill exercise test could be applicable and useful to predict long term prognosis. (author)

  13. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center.

    Science.gov (United States)

    Gibbons, Raymond J; Askew, J Wells; Hodge, David; Miller, Todd D

    2010-03-01

    The purpose of this study was to apply published appropriateness criteria for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in a single academic medical center to determine if the percentage of inappropriate studies was changing over time. In a previous study, we applied the American College of Cardiology Foundation/American Society of Nuclear Cardiology (ASNC) appropriateness criteria for stress SPECT MPI and reported that 14% of stress SPECT studies were performed for inappropriate reasons. Using similar methodology, we retrospectively examined 284 patients who underwent stress SPECT MPI in October 2006 and compared the findings to the previous cohort of 284 patients who underwent stress SPECT MPI in May 2005. The indications for testing in the 2 cohorts were very similar. The overall level of agreement in characterizing categories of appropriateness between 2 experienced cardiovascular nurse abstractors was good (kappa = 0.68), which represented an improvement from our previous study (kappa = 0.56). There was a significant change between May 2005 and October 2006 in the overall classification of categories for appropriateness (P = .024 by chi(2) statistic). There were modest, but insignificant, increases in the number of patients who were unclassified (15% in the current study vs 11% previously), appropriate (66% vs 64%), and uncertain (12% vs 11%). Only 7% of the studies in the current study were inappropriate, which represented a significant (P = .004) decrease from the 14% reported in the 2005 cohort. In the absence of any specific intervention, there was a significant change in the overall classification of SPECT appropriateness in an academic medical center over 17 months. The only significant difference in individual categories was a decrease in inappropriate studies. Additional measurements over time will be required to determine if this trend is sustainable or generalizable.

  14. Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.

    Science.gov (United States)

    Sommerauer, Michael; Graf, Carmen; Schäfer, Niklaus; Huber, Gerhard; Schneider, Paul; Wüthrich, Rudolf; Schmid, Christoph; Steinert, Hans

    2015-01-01

    Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 ± 46 vs. 129 ± 41 minutes, p = 0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.

  15. Reduction of renal uptake of 111In-DOTA-labeled and A700-labeled RAFT-RGD during integrin αvβ3 targeting using single photon emission computed tomography and optical imaging.

    Science.gov (United States)

    Briat, Arnaud; Wenk, Christiane H F; Ahmadi, Mitra; Claron, Michael; Boturyn, Didier; Josserand, Véronique; Dumy, Pascal; Fagret, Daniel; Coll, Jean-Luc; Ghezzi, Catherine; Sancey, Lucie; Vuillez, Jean-Philippe

    2012-06-01

    Integrin α(v)β(3) expression is upregulated during tumor growth and invasion in newly formed endothelial cells in tumor neovasculature and in some tumor cells. A tetrameric RGD-based peptide, regioselectively addressable functionalized template-(cyclo-[RGDfK])4 (RAFT-RGD), specifically targets integrin α(v)β(3) in vitro and in vivo. When labeled with indium-111, the RAFT-RGD is partially reabsorbed and trapped in the kidneys, limiting its use for further internal targeted radiotherapy and imaging investigations. We studied the effect of Gelofusine on RAFT-RGD renal retention in tumor-bearing mice. Mice were imaged using single photon emission computed tomography and optical imaging 1 and 24 h following tracer injection. Distribution of RAFT-RGD was further investigated by tissue removal and direct counting of the tracer. Kidney sections were analyzed by confocal microscopy. Gelofusine significantly induced a >50% reduction of the renal reabsorption of (111)In-DOTA-RAFT-RGD and A700-RAFT-RGD, without affecting tumor uptake. Injection of Gelofusine significantly reduced the renal retention of labeled RAFT-RGD, while increasing the tumor over healthy tissue ratio. These results will lead to the development of future therapeutic approaches. © 2012 Japanese Cancer Association.

  16. Thermoelectric single-photon detector

    International Nuclear Information System (INIS)

    Kuzanyan, A A; Petrosyan, V A; Kuzanyan, A S

    2012-01-01

    The ability to detect a single photon is the ultimate level of sensitivity in the measurement of optical radiation. Sensors capable of detecting single photons and determining their energy have many scientific and technological applications. Kondo-enhanced Seebeck effect cryogenic detectors are based on thermoelectric heat-to-voltage conversion and voltage readout. We evaluate the prospects of CeB 6 and (La,Ce)B 6 hexaboride crystals for their application as a sensitive element in this type of detectors. We conclude that such detectors can register a single UV photon, have a fast count rate (up to 45 MHz) and a high spectral resolution of 0.1 eV. We calculate the electric potential generated along the thermoelectric sensor upon registering a UV single photon.

  17. Single-photon decision maker

    Science.gov (United States)

    Naruse, Makoto; Berthel, Martin; Drezet, Aurélien; Huant, Serge; Aono, Masashi; Hori, Hirokazu; Kim, Song-Ju

    2015-08-01

    Decision making is critical in our daily lives and for society in general and is finding evermore practical applications in information and communication technologies. Herein, we demonstrate experimentally that single photons can be used to make decisions in uncertain, dynamically changing environments. Using a nitrogen-vacancy in a nanodiamond as a single-photon source, we demonstrate the decision-making capability by solving the multi-armed bandit problem. This capability is directly and immediately associated with single-photon detection in the proposed architecture, leading to adequate and adaptive autonomous decision making. This study makes it possible to create systems that benefit from the quantum nature of light to perform practical and vital intelligent functions.

  18. Measurements of regional cerebral blood flow (rCBF) using dynamic single-photon emission computed tomography (DSPECT): Definition of a generally acceptable normal range and follow-up checks after extracranial bypass surgery

    International Nuclear Information System (INIS)

    Kreisig, T.

    1986-01-01

    The usefulness of dynamic single-photon emission computed tomography was evaluated in 50 volunteers with unobtrusive cerebral findings, who were to provide the relevant standard values. It was found that the values measured were easily reproducible. Measurements in patients showing cerebrovascular disease that were carried out before and after extracranial bypass surgery did mostly not suggest any perceivable improvement of cerebral blood flow. In isolated cases the cerebral reserve was influenced favourably, as judged from measurements after administration of acetazolamide. (MBC) [de

  19. Single photon searches at PEP

    Energy Technology Data Exchange (ETDEWEB)

    Hollebeek, R.

    1985-12-01

    The MAC and ASP searches for events with a single photon and no other observed particles are reviewed. New results on the number of neutrino generations and limits on selection, photino, squark and gluino masses from the ASP experiment are presented.

  20. Single photon searches at PEP

    International Nuclear Information System (INIS)

    Hollebeek, R.

    1985-12-01

    The MAC and ASP searches for events with a single photon and no other observed particles are reviewed. New results on the number of neutrino generations and limits on selection, photino, squark and gluino masses from the ASP experiment are presented

  1. Correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography and clinical presentations in patients with low cobalamin status.

    Science.gov (United States)

    Tu, Min-Chien; Lo, Chung-Ping; Chen, Ching-Yuan; Huang, Ching-Feng

    2015-12-03

    Cobalamin (Cbl) deficiency has been associated with various neuropsychiatric symptoms of different severities. While some studies dedicated in structural neuroimaging credibly address negative impact of low Cbl status, functional imaging reports are limited. We herein retrospectively review the correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography (Tc-99 m-ECD SPECT) and clinical presentations among patients with low serum cobalamin (Cbl) status (Tc-99 m-ECD SPECT, and neuropsychological tests were reviewed. Dysexecutive syndrome (67 %), forgetfulness (50 %), attention deficits (42 %), and sleep disorders (33 %) constituted the major clinical presentations. All patients (100 %) had temporal hypoperfusion on the Tc-99 m-ECD SPECT. Five patients (42 %) had hypoperfusion restricted within temporal regions and deep nuclei; seven patients (58 %) had additional frontal hypoperfusion. In patients with hypoperfusion restricted within temporal regions and deep nuclei, psychiatric symptoms with spared cognition were their main presentations. Among patients with additional frontal hypoperfusion, six of seven patients (86 %) showed impaired cognitive performances (two of them were diagnosed as having dementia). Among ten patients who finished neuropsychological tests, abstract thinking (70 %) was the most commonly affected, followed by verbal fluency (60 %), short-term memory (50 %), and attention (50 %). Anxiety and sleep problems were the major clinically remarkable psychiatric features (33 % both). Four Tc-99 m-ECD SPECT follow-up studies were available; the degree and extent of signal reversal correlated with cognitive changes after Cbl replacement therapy. Our TC-99 m-ECD SPECT observations provide pivotal information of neurobiological changes within basal ganglia and fronto-temporal regions in conjunction with disease severity among patients with Cbl deficiency. Hypoperfusion within thalamus/basal ganglia and temporal regions may be

  2. Myocardial perfusion assessed by contrast echocardiography and single photon emission computed tomography in the evaluation of patients with acute chest pain and normal electrocardiogram

    International Nuclear Information System (INIS)

    Soares, J. Jr.; Ferreira, S.M.A.; Matias, W. Jr.; Giorgi, M.C.P.; Izaki, M.; Luz, P.L.; Ramires, J.A.F.; Meneghetti, J.C.

    2002-01-01

    Aim : Evaluation of diagnostic accuracy of myocardial contrast echocardiography (MCE) in comparison with single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia in patients with acute chest pain. Material and Methods : Eighteen patients (pts) with chest pain lasting ≥30 minutes, occurring within 6 hours of emergency room presentation and a normal or no diagnostic electrocardiogram were studied. Pts underwent rest MCE and SPECT. For both exams myocardial perfusion was assessed in the same 7 segments (apical, anterior, inferior, anteroseptal, inferoseptal, lateral and posterior) of left ventricle. A total of 126 segments were analyzed. Images were classified as positive for ischemia if they had a perfusion defect. Coronary angiography was performed if MCE or SPECT images were classified as positive for ischemia or by clinical indication. Otherwise the patients underwent stress SPECT. Significant coronary artery disease (CAD) was defined as ≥70% stenosis in a major coronary artery or its branches. Final diagnosis of an acute coronary event (ACE) was established in the presence of positive findings in MCE or SPECT in addition to significant CAD in the corresponding territory. Kappa statistics were calculated to evaluate the concordance between MCE and SPECT. κ values of ≤0.4, >0.4 and >0.7 indicate fair, good and excellent agreement, respectively. Results: Thirteen out of 18 pts underwent coronary angiography (seven pts had positive findings on SPECT, 2 on MCE, 2 on both exams and 1 had clinical indication). Significant CAD was detected on six. Five pts underwent stress SPECT and no perfusion defect was detected. Therefore, six pts (33.3%) had an ACE and 12 (66.6%) had not. There were no statistical differences between groups according to age, gender, duration of pain, free pain interval, presence of risk factors and antecedents. Concordance between MCE and SPECT for evaluation of perfusion defects showed a ? coefficient of 0

  3. Differentiating between visual hallucination-free dementia with Lewy bodies and corticobasal syndrome on the basis of neuropsychology and perfusion single-photon emission computed tomography.

    Science.gov (United States)

    Misch, Michael R; Mitchell, Sara; Francis, Philip L; Sherborn, Kayla; Meradje, Katayoun; McNeely, Alicia A; Honjo, Kie; Zhao, Jiali; Scott, Christopher Jm; Caldwell, Curtis B; Ehrlich, Lisa; Shammi, Prathiba; MacIntosh, Bradley J; Bilbao, Juan M; Lang, Anthony E; Black, Sandra E; Masellis, Mario

    2014-01-01

    Dementia with Lewy bodies (DLB) and Corticobasal Syndrome (CBS) are atypical parkinsonian disorders with fronto-subcortical and posterior cognitive dysfunction as common features. While visual hallucinations are a good predictor of Lewy body pathology and are rare in CBS, they are not exhibited in all cases of DLB. Given the clinical overlap between these disorders, neuropsychological and imaging markers may aid in distinguishing these entities. Prospectively recruited case-control cohorts of CBS (n =31) and visual hallucination-free DLB (n =30), completed neuropsychological and neuropsychiatric measures as well as brain perfusion single-photon emission computed tomography and structural magnetic resonance imaging (MRI). Perfusion data were available for forty-two controls. Behavioural, perfusion, and cortical volume and thickness measures were compared between the groups to identify features that serve to differentiate them. The Lewy body with no hallucinations group performed more poorly on measures of episodic memory compared to the corticobasal group, including the delayed and cued recall portions of the California Verbal Learning Test (F (1, 42) =23.1, P reproduction of the Wechsler Memory Scale-Revised (F (1, 36) =9.7, P =0.004). The Lewy body group also demonstrated reduced perfusion in the left occipital pole compared to the corticobasal group (F (1,57) =7.4, P =0.009). At autopsy, the Lewy body cases all demonstrated mixed dementia with Lewy bodies, Alzheimer's disease and small vessel arteriosclerosis, while the corticobasal cases demonstrated classical corticobasal degeneration in five, dementia with agyrophilic grains + corticobasal degeneration + cerebral amyloid angiopathy in one, Progressive Supranuclear Palsy in two, and Frontotemporal Lobar Degeneration-Ubiquitin/TAR DNA-binding protein 43 proteinopathy in one. MRI measures were not significantly different between the patient groups. Reduced perfusion in the left occipital region and worse

  4. The usefulness of dipyridamole thallium-201 single photon emission computed tomography for predicting perioperative cardiac events in patients undergoing non-cardiac vascular surgery

    International Nuclear Information System (INIS)

    Chen Tao; Huang Gang

    2004-01-01

    The aim of this study was to evaluate the usefulness of dipyridamole Tl-201 myocardium single photon emission computed tomography (201Tl-SPECT) for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) and abdominal aortic aneurysm (AAA) undergoing non-cardiac vascular surgery. Methods: Preoperative dipyridamole 201Tl-SPECT imaging in association with clinical risk assessment was performed in 224 consecutive patients (97 ASO and 127 AAA). Results: The patients were classified into three groups, including low-risk (n=173, 77%), intermediate-risk (n=39, 18%), and high-risk (n=12, 5%) groups according to the clinical risk stratification. The prevalence of reversible Tl-201 defect was significantly higher in the high-risk group than that in the low-risk group (83% vs. 14%, p<0.001). In 180 patients who underwent vascular surgery, 9 patients (5.0%) had perioperative cardiac events, including heart failure (n=l), unstable angina (n=2), and other cardiac events such as arrhythmias (n=6). The clinical variables including the clinical risk stratification did not significantly correlate with the perioperative cardiac events. In contrast, the reversible defect on 201Tl-SPECT was the only variable to predict perioperative cardiac events by a stepwise logistic regression analysis (odds ratio 7.0, 95% confidence interval l.7-28.0, p=0.007). It was also a significant predictor of perioperative cardiac events in a subgroup of low risk patients (odds ratio 11.6, 95% confidence interval 2.3-57.4, p=0.004). The sensitivity and specificity of the reversible defect for predicting perioperative cardiac events were 55.6% and 84.8% in all operated patients, and 57.1% and 89.7% in low risk patients, respectively. Conclusions: The preoperative dipyridamole 201Tl-SPECT was useful for predicting perioperative cardiac events in patients with vascular diseases, even in patients identified as having a low risk based on the clinical risk assessment. (authors)

  5. Effect of post-myocardial infarction streptokinase (sk) therapy, on myocardial viability - evaluation with thallium-201 single photon emission computed tomography (TL-201 SPECT)

    International Nuclear Information System (INIS)

    Shaikh, M.S.; Raza, M.; Kayani, A.M.; Fazal, I.

    2011-01-01

    To evaluate the effect of post-myocardial infarction Streptokinase therapy on myocardial viability, employing Thallium-201 single photon emission computed tomography (TL-201 SPECT). Design: Retrospective, experimental study. Place and duration of study: The Nuclear Cardiology Department, Armed Forces Institute of Cardiology / National Institute of Heart Diseases, Rawalpindi, from 1 April, 2009 to 31 October, 2009. Patients and Methods: Male patients, who had suffered from acute myocardial infarction (AMI), in an area supplied by the left anterior descending (LAD) artery, had infarct-related electrocardiogram (ECG) changes and received or did not receive Streptokinase therapy, were included. Those with a normal ECG, or history of revascularisation, or non-ST elevation MI, or more than one MIs, were excluded. The patients were divided into groups 1 (who received Streptokinase) and 2 (who did not receive Streptokinase). Each group contained 42 patients and all underwent scintigraphic viability study through intravenous injection of 3.0 mCi (123 MBq) of TL-201, followed by rest-redistribution SPECT imaging on a dual head, dedicated cardiac gamma camera system (Philips Cardio MD). Emory's cardiac toolbox and AutoQUANT were used for data processing and quantitative estimation of viable myocardium. Empirical scores from 0 to 2 were assigned to each of the scans, in the order of increasing viability, and these were compared across the two groups. Result: Group 1 contained 42 patients (age range = 38 to 80 years, mean = 53.98 +- 11.26 years), in whom empirical viability scoring was done. Score 0 was seen in 2 patients, score 1 was seen in 15 patients and score 2 was seen in 25 patients form this group. Group 2 also contained 42 patients (age range = 38 to 80 years, mean = 56.71 +- 9.05 years), in whom viability score of 0 was seen in 3 patients, score 1 was seen in 11 patients and score 2 was seen in 28 patients form this group. Age difference between the two groups was

  6. Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation

    Energy Technology Data Exchange (ETDEWEB)

    Neill, Johanne [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); The Prince Charles Hospital, Brisbane (Australia); Prvulovich, Elizabeth M.; Bomanji, Jamshed B. [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Fish, Matthews B. [Sacred Heart Medical Center (SHMC), Springfield, OR (United States); Berman, Daniel S.; Slomka, Piotr J. [Cedars-Sinai Medical Center, Los Angeles, CA (United States); Sharir, Tali [Procardia Maccabi Healthcare Services (PMHS), Tel Aviv (Israel); Martin, William H. [Vanderbilt University Medical Center (VUMC), Nashville, TN (United States); DiCarli, Marcelo F. [Brigham and Women' s Hospital (BWH), Boston, MA (United States); Ziffer, Jack A. [Baptist Hospital of Miami (BHM), Miami, FL (United States); Shiti, Dalia [Spectrum-Dynamics, Caesarea (Israel); Ben-Haim, Simona [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Chaim Sheba Medical Center, Department of Nuclear Medicine, Tel-Hashomer (Israel)

    2013-07-15

    High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS {>=}3 or coronary territorial SSS {>=}2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5 % and coronary territorial TPD {>=}3 % were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; {>=}50 % was considered significant. Of the 50 patients, 13 (26 %) had no stenosis, 22 (44 %) had single-vessel disease, 6 (12 %) had double-vessel disease and 9 (18 %) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's {rho} 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92 % (35/38), 83 % (10/12) and 90 % (45/50) vs. 84 % (32/38), 50 % (6/12) and 76 % (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89 % (31/35), 57 % (8/14) and 80 % (39/49) vs. 86 % (31/36), 77 % (10/13) and 84 % (41/49), respectively. HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual

  7. Preliminary clinical study in patients with hemispatial neglect after stroke by neglect test battery and 99mTc-ECD single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yin Yafu; Li Xuena; Li Yaming; Gu Hui; Han Chunqi; Liu Hao

    2009-01-01

    Objective: To explore the presence, clinical characteristics, anatomical foci in image and mechanism of hemispatial neglect (HSN), neglect test battery and single-photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) imaging were performed on patients with stroke. Methods: Thirty dextromanual patients who were diagnosed as having unilateral stroke clinically were recruited. A neglect test battery including line bisection test, star cancellation test and drawing test was performed on the subjects. The severity of neglect was measured on neglect tests. The lowest rCBF, the range with decreased rCBF, number of the foci with decreased rCBF, the flow deficit size and the total number of pixels in the foci were measured on SPECT rCBF imaging. Results: Twenty-five patients were diagnosed as having HSN by the neglect test battery. Contralateral neglect (CN) and ipsilateral neglect (IN) were observed in both right and left hemisphere strokes. On SPECT imaging, the patients with neglect had decreased rCBF in the frontal cortex most often; followed by the parietal, occipital and temporal cortices; and basal ganglia and thalamus in some cases. The patients who had two or more regions damaged showed neglect more often and severity. The correlation coefficients between rCBF in the foci, the decreased percentage of rCBF of the foci and the severity of neglect were -0.119 (P>.05) and 0.221 (P>.05). The correlation coefficients between the range, number of foci, the flow deficit size, the total number of pixels of the foci and the severity of neglect were 0.537 (P<.05), 0.493 (P<.05), 0.561 (P<.05), 0.466 (P<.05), respectively. No difference between CN and IN on SPECT images reached statistical significance. Conclusions: The severity of neglect did not correlate with rCBF and the decreased percentage of rCBF in the foci, while it was significantly correlated with the range, number of foci, the flow deficit size and the total numbers of pixels of the foci

  8. Noninvasive evaluation of nicotinic acetylcholine receptor availability in mouse brain using single-photon emission computed tomography with [123I]5IA

    International Nuclear Information System (INIS)

    Matsuura, Yuki; Ueda, Masashi; Higaki, Yusuke; Watanabe, Keiko; Habara, Shogo; Kamino, Shinichiro; Saji, Hideo; Enomoto, Shuichi

    2016-01-01

    Introduction: Nicotinic acetylcholine receptors (nAChRs) are of great interest because they are implicated in higher brain functions. Nuclear medical imaging is one of the useful techniques for noninvasive evaluation of physiological and pathological function in living subjects. Recent progress in nuclear medical imaging modalities enables the clear visualization of the organs of small rodents. Thus, translational research using nuclear medical imaging in transgenic mice has become possible and helps to elucidate human disease pathology. However, imaging of α4β2 nAChRs in the mouse brain has not yet been performed. The purpose of this study was to assess the feasibility of single-photon emission computed tomography (SPECT) with 5-[ 123 I]iodo-3-[2(S)-azetidinylmethoxy]pyridine ([ 123 I]5IA) for evaluating α4β2 nAChR availability in the mouse brain. Methods: A 60-min dynamic SPECT imaging session of α4β2 nAChRs in the mouse brain was performed. The regional distribution of radioactivity in the SPECT images was compared to the density of α4β2 nAChRs measured in an identical mouse. Alteration of nAChR density in the brains of Tg2576 mice was also evaluated. Results: The mouse brain was clearly visualized by [ 123 I]5IA-SPECT and probe accumulation was significantly inhibited by pretreatment with (−)-nicotine. The regional distribution of radioactivity in SPECT images showed a significant positive correlation with α4β2 nAChR density measured in an identical mouse brain. Moreover, [ 123 I]5IA-SPECT was able to detect the up-regulation of α4β2 nAChRs in the brains of Tg2576 transgenic mice. Conclusions: [ 123 I]5IA-SPECT imaging would be a promising tool for evaluating α4β2 nAChR availability in the mouse brain and may be useful in translational research focused on nAChR-related diseases.

  9. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  10. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    Aharonovich, I; Castelletto, S; Simpson, D A; Su, C-H; Greentree, A D; Prawer, S

    2011-01-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  11. Design and preliminary assessment of 99mTc-labeled ultrasmall superparamagnetic iron oxide-conjugated bevacizumab for single photon emission computed tomography/magnetic resonance imaging of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yanzhao Zhao; Hui Tan; Bing Wu; Pengcheng Hu; Pengyue Wu; Yushen Gu; Dengfeng Cheng; Hongcheng Shi; Qi Yao; Chunfu Zhang

    2014-01-01

    Hepatocellular carcinoma (HCC) has a very high incidence and mortality. Early diagnosis and timely treatments are therefore required to improve the quality of life and survival rate of HCC patients. Here, we developed a vascular endothelial growth factor (VEGF)-based multimodality imaging agent for single photon emission computed tomography (SPECT), computed tomography (CT) and magnetic resonance imaging (MRI) and used it to assess HCC mice and explore the combinative value of CT/MRI-based morphological imaging and SPECT functional imaging. HCC targeting with 125 I-labeled bevacizumab monoclonal antibody (mAb) was examined using SPECT/CT in HepG2 tumor-bearing mice after intravenous mAb injection. Based on this, an integrated, bimodal, VEGF-targeted, ultrasmall superparamagnetic iron oxide (USPIO)-conjugated 99m Tc-labeled bevacizumab mAb was synthesized to increase tumor penetration and accumulations. The in vivo pharmacokinetics and HepG2 tumor targeting were explored through in vivo planar imaging and SPECT/CT using a mouse model of HepG2 liver cancer. The specificity of the radiolabeled nanoparticles for HepG2 HCC was verified using in vitro immunohistochemistry and Prussian blue staining. With diethylenetriamine pentaacetic acid as a bifunctional chelating agent, USPIO-bevacizumab achieved a 99m Tc labeling efficiency of >90 %. The in vivo imaging results also exhibited the targeting of USPIO on HepG2 HCC. The specificity of these results was confirmed using in vitro immunohistochemistry and Prussian blue staining. Our preliminary findings showed the potential of USPIO as an imaging agent for the SPECT/MRI of HepG2 HCC. (author)

  12. Use of 99mTc-sestamibi Single-photon Emission Computed Tomography / X-ray Computed Tomography in the Diagnosis of Hybrid Oncocytic / Chromophobe Tumor in a Pediatric Patient.

    Science.gov (United States)

    Almassi, Nima; Gorin, Michael A; Purysko, Andrei S; Rowe, Steven P; Kaouk, Jihad; Allaf, Mohamad E; Campbell, Steven C; Rhee, Audrey

    2018-03-01

    The differential diagnosis of solid renal neoplasms in adolescence includes aggressive malignancy and indolent oncocytic tumors, which are typically indistinguishable using conventional imaging. We report the use of 99m Tc-sestamibi single-photon emission computed tomography / x-ray computed tomography (SPECT/CT) in characterizing enhancing renal neoplasms in a pediatric patient. Genetic testing suggested a hereditary syndrome associated with aggressive malignancy, whereas renal mass biopsy suggested an oncocytic tumor. 99m Tc-sestamibi SPECT/CT indicated probable oncocytomas or hybrid oncocytic / chomophobe tumors. Enucleative resection was performed with final pathology demonstrating hybrid oncocytic / chomophobe tumors. This case highlights the potential utility of 99m Tc-sestamibi SPECT/CT in characterizing indeterminate enhancing renal neoplasm in pediatric patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. [The value of multimodal imaging by single photon emission computed tomography associated to X ray computed tomography (SPECT-CT) in the management of differentiated thyroid carcinoma: about 156 cases].

    Science.gov (United States)

    Mhiri, Aida; El Bez, Intidhar; Slim, Ihsen; Meddeb, Imène; Yeddes, Imene; Ghezaiel, Mohamed; Gritli, Saïd; Ben Slimène, Mohamed Faouzi

    2013-10-01

    Single photon emission computed tomography combined with a low dose computed tomography (SPECT-CT), is a hybrid imaging integrating functional and anatomical data. The purpose of our study was to evaluate the contribution of the SPECTCT over traditional planar imaging of patients with differentiated thyroid carcinoma (DTC). Post therapy 131IWhole body scan followed by SPECTCT of the neck and thorax, were performed in 156 patients with DTC. Among these 156 patients followed for a predominantly papillary, the use of fusion imaging SPECT-CT compared to conventional planar imaging allowed us to correct our therapeutic approach in 26.9 % (42/156 patients), according to the protocols of therapeutic management of our institute. SPECT-CT is a multimodal imaging providing better identification and more accurate anatomic localization of the foci of radioiodine uptake with impact on therapeutic management.

  14. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  15. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  16. Deterministic and Storable Single-Photon Source Based on a Quantum Memory

    International Nuclear Information System (INIS)

    Chen Shuai; Chen, Y.-A.; Strassel, Thorsten; Zhao Bo; Yuan Zhensheng; Pan Jianwei; Schmiedmayer, Joerg

    2006-01-01

    A single-photon source is realized with a cold atomic ensemble ( 87 Rb atoms). A single excitation, written in an atomic quantum memory by Raman scattering of a laser pulse, is retrieved deterministically as a single photon at a predetermined time. It is shown that the production rate of single photons can be enhanced considerably by a feedback circuit while the single-photon quality is conserved. Such a single-photon source is well suited for future large-scale realization of quantum communication and linear optical quantum computation

  17. Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography

    Directory of Open Access Journals (Sweden)

    Kamaleshwaran Koramadai Karuppusamy

    2015-01-01

    Full Text Available High doses of iodine-131 are commonly used in patients with differentiated thyroid cancer after total or subtotal thyroidectomy, in order to ablate the remaining cancer or normal thyroid tissue. Multiple different false-positive scans can occur in the absence of residual thyroid tissue or metastases. The authors present a case of abnormal uptake of radioactive iodine in the aspergilloma, potentially masquerading as pulmonary metastases.

  18. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  19. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by 99m technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    International Nuclear Information System (INIS)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian

    2014-01-01

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a 99m technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of 99m technetium sulfur colloid SPECT/CT imaging in this rare condition.

  20. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    OpenAIRE

    Pan-Fu Kao; Shiaw-Pyng Wey; An-Shoei Yang

    2009-01-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)amino]ethyl]amino]ethanethiolato(3-)-N2,N2′,S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition...

  1. Tailoring single-photon and multiphoton probabilities of a single-photon on-demand source

    International Nuclear Information System (INIS)

    Migdall, A.L.; Branning, D.; Castelletto, S.

    2002-01-01

    As typically implemented, single-photon sources cannot be made to produce single photons with high probability, while simultaneously suppressing the probability of yielding two or more photons. Because of this, single-photon sources cannot really produce single photons on demand. We describe a multiplexed system that allows the probabilities of producing one and more photons to be adjusted independently, enabling a much better approximation of a source of single photons on demand

  2. Single photon emission computerized tomography

    International Nuclear Information System (INIS)

    Hooge, P. de.

    1983-01-01

    In this thesis two single-photon emission tomographic techniques are presented: (a) longitudinal tomography with a rotating slanting-hole collimator, and (b) transversal tomography with a rotating gamma camera. These methods overcome the disadvantages of conventional scintigraphy. Both detection systems and the image construction methods are explained and comparisons with conventional scintigraphy are drawn. One chapter is dedicated to the determination of system parameters like spatial resolution, contrast, detector uniformity, and size of the object, by phantom studies. In separate chapters the results are presented of detection of tumors and metastases in the liver and the liver hilus; skeletal diseases; various pathological aberrations of the brain; and myocardial perfusion. The possible use of these two ect's for other organs and body areas is discussed in the last chapter. (Auth.)

  3. Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab

    International Nuclear Information System (INIS)

    Johnson, L.L.; Lerrick, K.S.; Coromilas, J.

    1987-01-01

    Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous injection of labeled Fab fragments with the use of a dual-head SPECT camera with medium-energy collimators. Immediately after the first tomographic scan, thallium-201 was injected into nine of 12 dogs and imaging was repeated. Estimated infarct size in grams was calculated from transaxially reconstructed, normalized, and background-corrected indium SPECT images with the use of a threshold technique for edge detection. Estimated noninfarcted myocardium in grams was calculated from obliquely reconstructed thallium SPECT images by a similar method. The animals were killed and infarct size in grams and true infarct size as a percentage of total left ventricular myocardial volume were measured by triphenyl tetrazolium chloride staining. Estimated infarct size from indium SPECT images showed an excellent correlation with true infarct size (r = .95, SEE = 4.1 g). Estimated percentage myocardium infarcted was calculated by dividing estimated infarct size from indium images by the sum of estimated infarct size plus estimated noninfarcted myocardium obtained from thallium images. Correlation between the estimated percentage of myocardium infarcted and true percentage of myocardium infarcted was excellent

  4. MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

    International Nuclear Information System (INIS)

    Accorsi, R.; Autiero, M.; Celentano, L.

    2007-01-01

    We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256x256 matrix of 55 μm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. 125 I, 27-35 keV, 99m Tc, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 μm at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29 mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140 keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor

  5. Multi-photon absorption limits to heralded single photon sources

    Science.gov (United States)

    Husko, Chad A.; Clark, Alex S.; Collins, Matthew J.; De Rossi, Alfredo; Combrié, Sylvain; Lehoucq, Gaëlle; Rey, Isabella H.; Krauss, Thomas F.; Xiong, Chunle; Eggleton, Benjamin J.

    2013-01-01

    Single photons are of paramount importance to future quantum technologies, including quantum communication and computation. Nonlinear photonic devices using parametric processes offer a straightforward route to generating photons, however additional nonlinear processes may come into play and interfere with these sources. Here we analyse spontaneous four-wave mixing (SFWM) sources in the presence of multi-photon processes. We conduct experiments in silicon and gallium indium phosphide photonic crystal waveguides which display inherently different nonlinear absorption processes, namely two-photon (TPA) and three-photon absorption (ThPA), respectively. We develop a novel model capturing these diverse effects which is in excellent quantitative agreement with measurements of brightness, coincidence-to-accidental ratio (CAR) and second-order correlation function g(2)(0), showing that TPA imposes an intrinsic limit on heralded single photon sources. We build on these observations to devise a new metric, the quantum utility (QMU), enabling further optimisation of single photon sources. PMID:24186400

  6. Graphene-Based Josephson-Junction Single-Photon Detector

    Science.gov (United States)

    Walsh, Evan D.; Efetov, Dmitri K.; Lee, Gil-Ho; Heuck, Mikkel; Crossno, Jesse; Ohki, Thomas A.; Kim, Philip; Englund, Dirk; Fong, Kin Chung

    2017-08-01

    We propose to use graphene-based Josephson junctions (GJJs) to detect single photons in a wide electromagnetic spectrum from visible to radio frequencies. Our approach takes advantage of the exceptionally low electronic heat capacity of monolayer graphene and its constricted thermal conductance to its phonon degrees of freedom. Such a system could provide high-sensitivity photon detection required for research areas including quantum information processing and radio astronomy. As an example, we present our device concepts for GJJ single-photon detectors in both the microwave and infrared regimes. The dark count rate and intrinsic quantum efficiency are computed based on parameters from a measured GJJ, demonstrating feasibility within existing technologies.

  7. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  8. Therapeutic effects of coenzyme Q10 on dilated cardiomyopathy. Assessment by {sup 123}I-BMIPP myocardial single photon emission computed tomography (SPECT). A multicenter trial in Osaka University Medical School Group

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Hori, Masatsugu [Osaka Univ. (Japan). Faculty of Medicine

    1996-01-01

    To evaluate therapeutic effects of Coenzyme Q10 (CoQ10), 15 patients with dilated cardiomyopathy were investigated by {sup 123}I-BMIPP myocardial single photon emission computed tomography (SPECT). The BMIPP defect score was determined semiquantitatively by using representative short and long axial SPECT images. Mean BMIPP defect score with CoQ10 treatment was significantly low, 7.7{+-}6.1 compared to 12.7{+-}7.4 without CoQ10 treatment. On the other hand, in 8 patients of dilated cardiomyopathy, % fractional shortening using echocardiography was not different before and after CoQ10 treatment. In conclusion, {sup 123}I-BMIPP myocardial SPECT was proved to be sensitive to evaluate the therapeutic effects of CoQ10, which improve myocardial mitochondrial function, in the cases of dilated cardiomyopathy. (author).

  9. A segmentectomy of the right upper lobe has an advantage over a right upper lobectomy regarding the preservation of the functional volume of the right middle lobe. Analysis by perfusion single-photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Yoshimoto, Kentaro; Nomori, Hiroaki; Mori, Takeshi; Ohba, Yasuomi; Shibata, Hidekatsu; Tashiro, Kuniyuki; Shiraishi, Shinya; Kobayashi, Toshiaki

    2010-01-01

    To evaluate the advantages of a segmentectomy of the right upper lobe (RUL) over a right upper (RU) lobectomy regarding the preservation of the functional volume of the right middle lobe (RML), the postoperative forced expiratory volume in one second (FEV 1 ) of the RML was compared between an RU lobectomy and an RUL segmentectomy, by using a coregistered perfusion single-photon emission computed tomography and computed tomography (SPECT/CT). The pulmonary function tests and perfusion SPECT/CT were conducted before and after surgery (RU lobectomy: 7; RUL segmentectomy: 13). The FEV 1 of the RML before and after surgery was calculated from the data of the pulmonary function test and SPECT/CT. In the RU lobectomy group, the percentage change of FEV 1 was 71%±12%, which was significantly lower in comparison to 92%±9% in the RUL segmentectomy group (P=0.001). In the lobectomy group, the preoperative FEV 1 of the RML was 0.17±0.101 which decreased significantly to 0.06±0.061 after surgery (P=0.009). In the segmentectomy group, FEV 1 of the RML before and after the surgery were 0.23±0.101 and 0.20±0.111, of which the difference was not significant. An RUL segmentectomy has an advantage over an RU lobectomy regarding the preservation of pulmonary function, due to a greater preservation of not only the lung tissue, but also the FEV 1 of the RML. (author)

  10. Single-photon manipulation in Nanophotonic Circuits

    DEFF Research Database (Denmark)

    Hansen, Sofie Lindskov

    Quantum dots in photonic nanostructures has long been known to be a very powerful and versatile solid-state platform for conducting quantum optics experiments. The present PhD thesis describes experimental demonstrations of single-photon generation and subsequent manipulation all realized...... on a gallium arsenide platform. This platform offers near-unity coupling between embedded single-photon emitters and a photonic mode, as well as the ability to suppress decoherence mechanisms, making it highly suited for quantum information applications. In this thesis we show how a single-photon router can...... be realized on a chip with embedded quantum dots. This allows for on-chip generation and manipulation of single photons. The router consists of an on-chip interferometer where the phase difference between the arms of the interferometer is controlled electrically. The response time of the device...

  11. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Energy Technology Data Exchange (ETDEWEB)

    Razali, Azhani Mohd, E-mail: azhani@nuclearmalaysia.gov.my; Abdullah, Jaafar, E-mail: jaafar@nuclearmalaysia.gov.my [Plant Assessment Technology (PAT) Group, Industrial Technology Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang (Malaysia)

    2015-04-29

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  12. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    International Nuclear Information System (INIS)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-01-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm

  13. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Science.gov (United States)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-04-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  14. Novel [99mTcN]2+ Labeled EGFR Inhibitors as Potential Radiotracers for Single Photon Emission Computed Tomography (SPECT Tumor Imaging

    Directory of Open Access Journals (Sweden)

    Mingxia Zhao

    2014-04-01

    Full Text Available The epidermal growth factor receptor (EGFR is overexpressed in many cancers, including breast, ovarian, endometrial and non-small cell lung cancer. An EGFR-specific imaging agent could facilitate clinical evaluation of primary tumors or metastases. To achieve this goal, 4-(2-aminoethylamino-6,7-dimethoxyquinazoline (ADMQ was synthesized based on a 4-aminoquinazoline core and then conjugated with N-mercapto- acetylglycine (MAG and N-mercaptoacetyltriglycine (MAG3, respectively, to give compounds 1 and 2. The final complexes [99mTcN]-1 and [99mTcN]-2 were successfully obtained with radiochemical purities of >99% and >98% as measured by radio-HPLC. No decomposition of the two complexes at room temperature was observed over a period of 2 h. Their partition coefficients indicated they were hydrophilic and the electrophoresis results showed they were negatively charged. Biodistribution in tumor-bearing mice demonstrated that the two new complexes showed tumor accumulation, high tumor-tomuscle (T/M ratios and fast clearance from blood and muscle. Between the two compounds, the 99mTcN-MAG3-ADMQ ([99mTcN]-2 showed the better characteristics, with the tumor/muscle and tumor/blood ratios reached 2.11 and 1.90 at 60 min post-injection, 4.20 and 1.10 at 120 min post-injection, suggesting it could be a promising radiotracer for SPECT tumor imaging.

  15. Optimization of pinhole single photon emission computed tomography (pinhole SPECT) reconstruction; Optimisation de la reconstruction en tomographie d'emission monophotonique avec colimateur stenope

    Energy Technology Data Exchange (ETDEWEB)

    Israel-Jost, V

    2006-11-15

    In SPECT small animal imaging, it is highly recommended to accurately model the response of the detector in order to improve the low spatial resolution. The volume to reconstruct is thus obtained both by back-projecting and de-convolving the projections. We chose iterative methods, which permit one to solve the inverse problem independently from the model's complexity. We describe in this work a Gaussian model of point spread function (PSF) whose position, width and maximum are computed according to physical and geometrical parameters. Then we use the rotation symmetry to replace the computation of P projection operators, each one corresponding to one position of the detector around the object, by the computation of only one of them. This is achieved by choosing an appropriate polar discretization, for which we control the angular density of voxels to avoid over-sampling the center of the field of view. Finally, we propose a new family of algorithms, the so-called frequency adapted algorithms, which enable to optimize the reconstruction of a given band in the frequency domain on both the speed of convergence and the quality of the image. (author)

  16. Validation of the Gate simulation platform in single photon emission computed tomography and application to the development of a complete 3-dimensional reconstruction algorithm

    International Nuclear Information System (INIS)

    Lazaro, D.

    2003-10-01

    Monte Carlo simulations are currently considered in nuclear medical imaging as a powerful tool to design and optimize detection systems, and also to assess reconstruction algorithms and correction methods for degrading physical effects. Among the many simulators available, none of them is considered as a standard in nuclear medical imaging: this fact has motivated the development of a new generic Monte Carlo simulation platform (GATE), based on GEANT4 and dedicated to SPECT/PET (single photo emission computed tomography / positron emission tomography) applications. We participated during this thesis to the development of the GATE platform within an international collaboration. GATE was validated in SPECT by modeling two gamma cameras characterized by a different geometry, one dedicated to small animal imaging and the other used in a clinical context (Philips AXIS), and by comparing the results obtained with GATE simulations with experimental data. The simulation results reproduce accurately the measured performances of both gamma cameras. The GATE platform was then used to develop a new 3-dimensional reconstruction method: F3DMC (fully 3-dimension Monte-Carlo) which consists in computing with Monte Carlo simulation the transition matrix used in an iterative reconstruction algorithm (in this case, ML-EM), including within the transition matrix the main physical effects degrading the image formation process. The results obtained with the F3DMC method were compared to the results obtained with three other more conventional methods (FBP, MLEM, MLEMC) for different phantoms. The results of this study show that F3DMC allows to improve the reconstruction efficiency, the spatial resolution and the signal to noise ratio with a satisfactory quantification of the images. These results should be confirmed by performing clinical experiments and open the door to a unified reconstruction method, which could be applied in SPECT but also in PET. (author)

  17. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease. Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yoda, Shunichi; Sato, Yuichi; Matsumoto, Naoya; Tani, Shigemasa; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2005-01-01

    Although the detection of wall motion abnormalities gives incremental value to myocardial perfusion single-photon emission computed tomography (SPECT) in the diagnosis of extensive coronary artery disease (CAD) and high-grade single-vessel CAD, whether or not it is useful in the diagnosis of mild, single-vessel CAD has not been studied previously. Separate acquisition, dual isotope electrocardiogram (ECG)-gated SPECT was performed in 97 patients with a low likelihood of CAD (Group 1) and 46 patients with single-vessel CAD (Group 2). Mild CAD was defined by stenosis of 50-75% (Group 2a, n=22) and moderate to severe CAD was defined by stenosis ≥76% (Group 2b, n=24). Myocardial perfusion and wall motion were graded by a 5 point-scale, 20-segment model. The sensitivity of myocardial perfusion alone was 50% for Group 2a, 83% for Group 2b and 67% for Group 2 as a whole. The overall specificity was 90%. When the wall motion analysis was combined, the sensitivity was increased to 82% in Group 2a and 92% in Group 2b. The ability to detect a wall motion abnormality immediately after exercise gives incremental diagnostic value to myocardial perfusion SPECT in the identification of mild, single-vessel CAD. (author)

  18. Methylphenidate DAT binding in adolescents with Attention-Deficit/ Hyperactivity Disorder comorbid with Substance Use Disorder--a single photon emission computed tomography with [Tc(99m)]TRODAT-1 study.

    Science.gov (United States)

    Szobot, Claudia M; Shih, Ming Chi; Schaefer, Thais; Júnior, Neivo; Hoexter, Marcelo Q; Fu, Ying Kai; Pechansky, Flávio; Bressan, Rodrigo A; Rohde, Luis A P

    2008-04-15

    Attention-Deficit/Hyperactivity Disorder (ADHD) is highly prevalent among adolescents with Substance Use Disorders (SUD). Effects of methylphenidate (MPH) on ADHD are attributed to its properties of blocking the dopamine transporter (DAT) in the striatum. However, it has been demonstrated that drug addiction is associated with dopaminergic system changes that may affect MPH brain effects, emphasizing the need to better understand MPH actions in subjects with ADHD+SUD. To evaluate the effect of an extended release formulation of MPH (MPH-SODAS) on DAT availability in 17 stimulant-naive ADHD adolescents with comorbid SUD (cannabis and cocaine). Subjects underwent two single photon emission computed tomography (SPECT) scans with [Tc(99m)]TRODAT-1, at baseline and after 3 weeks on MPH-SODAS. Clinical assessment for ADHD relied on the Swanson, Nolan and Pelham Scale - version IV (SNAP-IV). Caudate and putamen DAT binding potential (BP) was calculated. After 3 weeks on MPH-SODAS, there was a significant reduction of SNAP-IV total scores (pADHD patients without SUD comorbidity, providing neurobiological support for trials with stimulants in adolescents with ADHD+SUD, an important population excluded from studies.

  19. Single photon emission computed tomography with N-isopropyl-p-(/sup 123/I) iodoamphetamine in dementia of the Alzheimer type. Comparative study in each stage and the difference between the hemispheres

    Energy Technology Data Exchange (ETDEWEB)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki; Yasui, Shinichi; Yuasa, Satoru; Shimizu, Akinori; Kurachi, Masayoshi; Seki, Hiroyasu; Fukuta, Tsutomu

    1989-05-01

    Correlation between brain uptake of N-isopropyl-p-(I-123)iodoamphetamine (I-123 IMP), as shown on single photon emission computed tomography (SPECT) scans, and clinical stages was examined in 8 patients with Alzheimer type dementia. The patients were clinically staged as Stage I (3), Stage II (3), or Stage III (2). The count ratio of each cerebral lobe to the cerebellum was calculated on horizontal SPECT scans. Stage I patients had a decreased I-123 IMP uptake in the temporal and parietal lobes. The decreased uptake in these areas became marked in Stage II patients, with diffusely slight uptake of I-123 IMP in the brain. In Stage III patients, the uptake of I-123 IMP was markedly decreased in the whole brain, including temporal, parietal, and frontal lobes. For five patients of Stage II and III, bilateral differences in the cerebral hemispheres were observed, corresponding to neurologic symptoms. Iodine-123 IMP SPECT was thus considered useful in clinically evaluating Alzheimer type dementia and in determining degenerative process of this disease. (Namekawa, K).

  20. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Lee, Won Woo; So, Young; Kim, Ki Bong; Lee, Dong Soo

    2014-01-01

    The aim of this study was to investigate the most robust predictor of myocardial viability among stress/rest reversibility (coronary flow reserve [CFR] impairment), 201 Tl perfusion status at rest, 201 Tl 24 hours redistribution and systolic wall thickening of 99m Tc-methoxyisobutylisonitrile using a dual isotope gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with coronary artery disease (CAD) who were re-vascularized with a coronary artery bypass graft (CABG) surgery. A total of 39 patients with CAD was enrolled (34 men and 5 women), aged between 36 and 72 years (mean 58 ± 8 standard in years) who underwent both pre- and 3 months post-CABG myocardial SPECT. We analyzed 17 myocardial segments per patient. Perfusion status and wall motion were semi-quantitatively evaluated using a 4-point grading system. Viable myocardium was defined as dysfunctional myocardium which showed wall motion improvement after CABG. The left ventricular ejection fraction (LVEF) significantly increased from 37.8 ± 9.0% to 45.5 ± 12.3% (p 201 Tl rest perfusion status (p = 0.024) were significant predictors of wall motion improvement. However, in multiple logistic regression analysis, stress/rest reversibility alone was a significant predictor for post-CABG wall motion improvement (p < 0.001). Stress/rest reversibility (impaired CFR) during dual-isotope gated myocardial perfusion SPECT was the single most important predictor of wall motion improvement after CABG.

  1. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  2. Effects of smoking on myocardial injury in patients with conservatively treated acute myocardial infarction. A study with resting {sup 123}I-15-iodophenyl 3-methyl pentadecanoic acid/{sup 201}Tl myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, Hiroyuki; Akioka, Kaname; Shirai, Naoya; Yoshiyama, Minoru; Teragaki, Masakazu; Takeuchi, Kazuhide; Yoshikawa, Junichi; Ochi, Hironobu [Osaka City Univ. (Japan). Graduate School of Medicine

    2001-09-01

    Many reports have demonstrated that smokers who have suffered an acute myocardial infarction (AMI) have a better prognosis than nonsmokers. The present study investigated the effects of current smoking on myocardial injury with resting {sup 123}I-15-iodophenyl 3-methyl pentadecanoic acid (BMIPP)/{sup 201}Tl myocardial single photon emission computed tomography in 103 patients with conservatively treated AMI. The left ventricular myocardium was divided into 9 segments and BMIPP and {sup 201}Tl defects were scored using a 5-point grading system (0=normal and 4=no uptake). The sum of the defect scores was defined as the total defect score. There was no significant difference in either the baseline severity of the coronary artery discase or the total defect scores for BMIPP and {sup 201}Tl between the current smoker and nonsmoker groups. The difference between the total defect scores for BMIPP and {sup 201}Tl tended to be larger in the current smoker group than in the nonsmoker group (2.0{+-}1.9 vs 1.3{+-}1.6, p=0.056). Forty-one (53%) of 77 patients in the current smoker group exhibited a BMIPP/{sup 201}Tl mismatch, whereas only 8 (31%) of 26 patients in the nonsmoker group did (p=0.047). In conclusion, current smokers had more likelihood of salvageable myocardium in areas at risk, as demonstrated by BMIPP/{sup 201}Tl mismatch, in AMI than nonsmokers. (author)

  3. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.

    Science.gov (United States)

    Ishihara, Masaru; Onoguchi, Masahisa; Taniguchi, Yasuyo; Shibutani, Takayuki

    2017-12-01

    The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.

  4. Effects of smoking on myocardial injury in patients with conservatively treated acute myocardial infarction. A study with resting 123I-15-iodophenyl 3-methyl pentadecanoic acid/201Tl myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Yamagishi, Hiroyuki; Akioka, Kaname; Shirai, Naoya; Yoshiyama, Minoru; Teragaki, Masakazu; Takeuchi, Kazuhide; Yoshikawa, Junichi; Ochi, Hironobu

    2001-01-01

    Many reports have demonstrated that smokers who have suffered an acute myocardial infarction (AMI) have a better prognosis than nonsmokers. The present study investigated the effects of current smoking on myocardial injury with resting 123 I-15-iodophenyl 3-methyl pentadecanoic acid (BMIPP)/ 201 Tl myocardial single photon emission computed tomography in 103 patients with conservatively treated AMI. The left ventricular myocardium was divided into 9 segments and BMIPP and 201 Tl defects were scored using a 5-point grading system (0=normal and 4=no uptake). The sum of the defect scores was defined as the total defect score. There was no significant difference in either the baseline severity of the coronary artery discase or the total defect scores for BMIPP and 201 Tl between the current smoker and nonsmoker groups. The difference between the total defect scores for BMIPP and 201 Tl tended to be larger in the current smoker group than in the nonsmoker group (2.0±1.9 vs 1.3±1.6, p=0.056). Forty-one (53%) of 77 patients in the current smoker group exhibited a BMIPP/ 201 Tl mismatch, whereas only 8 (31%) of 26 patients in the nonsmoker group did (p=0.047). In conclusion, current smokers had more likelihood of salvageable myocardium in areas at risk, as demonstrated by BMIPP/ 201 Tl mismatch, in AMI than nonsmokers. (author)

  5. [123I]N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane single-photon emission computed tomography brain imaging in the diagnosis of dementia with Lewy bodies.

    Science.gov (United States)

    Walker, Zuzana; Cummings, Jeffrey L

    2012-01-01

    Early, accurate diagnosis of dementia with Lewy bodies (DLB), in particular its differentiation from Alzheimer's disease, is important for optimal management, providing patients/carers with information about the likely symptomatology and illness course, allowing initiation of effective pharmacotherapy, and avoiding the consequences of neuroleptic sensitivity. Clinical diagnosis of DLB has high specificity but low sensitivity. Clinical trials of [(123)I]N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane single-photon emission computed tomography ([(123)I]FP-CIT SPECT) indicate high positive and negative percent agreement with reference to clinical diagnosis, and high sensitivity and specificity in patients with neuropathologically confirmed diagnoses of DLB. An abnormal [(123)I]FP-CIT SPECT image in patients fulfilling criteria for possible DLB advances the certainty of a diagnosis to probable DLB. [(123)I]FP-CIT SPECT, by identifying the striatal dopaminergic deficit, can be a valuable diagnostic aid and can provide support to a clinical diagnosis of DLB in patients with dementia. The technique is likely to be of particular utility in patients with dementia with an uncertain diagnosis. Copyright © 2012 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  6. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  7. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi

    2000-01-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V 2 , V 3 and V 4 leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV F , V 5 and V 6 leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  8. Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography in patients with major cerebral artery steno-occlusive diseases

    International Nuclear Information System (INIS)

    Saito, Hideo; Ogasawara, Kuniaki; Suzuki, Taro; Kuroda, Hiroki; Kobayashi, Masakazu; Yoshida, Kenji; Kubo, Yoshitaka; Ogawa, Akira

    2011-01-01

    Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography (SPECT) were prospectively investigated in 100 patients with major cerebral artery, atherosclerotic, and steno-occlusive diseases. All patients underwent two SPECT studies (with and without acetazolamide challenge) at an interval of 2 or 3 days, received a questionnaire immediately after each SPECT study, and returned the answered questionnaire within 7 days after the study. None of the 100 patients studied experienced any symptoms during the SPECT study without acetazolamide challenge. Sixty-three patients (63%) developed symptoms during the SPECT study with acetazolamide challenge, such as headache, nausea, dizziness, tinnitus, numbness of the extremities, motor weakness of the extremities, and general malaise 1-3 hours (mean 1.6 hours) after administration of acetazolamide, and these symptoms lasted for 0.5-72 hours (mean 7.9 hours). Multivariate statistical analysis revealed that younger age (95% confidence interval [CI] 0.896-0.980, p=0.0047) and female sex (95% CI 1.178-16.129, p=0.0274) were significantly associated with development of symptoms with acetazolamide challenge. The incidences of the development of symptoms with acetazolamide challenge were 91% (21/23) and 41% (12/29) in subgroups of women <70 years and men ≥70 years, respectively. Patients should be informed of such adverse effects of intravenous acetazolamide administration prior to the acetazolamide challenge test for evaluation of cerebrovascular reactivity. (author)

  9. Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography in patients with major cerebral artery steno-occlusive diseases

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Hideo; Ogasawara, Kuniaki; Suzuki, Taro; Kuroda, Hiroki; Kobayashi, Masakazu; Yoshida, Kenji; Kubo, Yoshitaka; Ogawa, Akira [Iwate Medical Univ., School of Medicine, Morioka, Iwate (Japan)

    2011-07-15

    Adverse effects of intravenous acetazolamide administration for evaluation of cerebrovascular reactivity using brain perfusion single-photon emission computed tomography (SPECT) were prospectively investigated in 100 patients with major cerebral artery, atherosclerotic, and steno-occlusive diseases. All patients underwent two SPECT studies (with and without acetazolamide challenge) at an interval of 2 or 3 days, received a questionnaire immediately after each SPECT study, and returned the answered questionnaire within 7 days after the study. None of the 100 patients studied experienced any symptoms during the SPECT study without acetazolamide challenge. Sixty-three patients (63%) developed symptoms during the SPECT study with acetazolamide challenge, such as headache, nausea, dizziness, tinnitus, numbness of the extremities, motor weakness of the extremities, and general malaise 1-3 hours (mean 1.6 hours) after administration of acetazolamide, and these symptoms lasted for 0.5-72 hours (mean 7.9 hours). Multivariate statistical analysis revealed that younger age (95% confidence interval [CI] 0.896-0.980, p=0.0047) and female sex (95% CI 1.178-16.129, p=0.0274) were significantly associated with development of symptoms with acetazolamide challenge. The incidences of the development of symptoms with acetazolamide challenge were 91% (21/23) and 41% (12/29) in subgroups of women <70 years and men {>=}70 years, respectively. Patients should be informed of such adverse effects of intravenous acetazolamide administration prior to the acetazolamide challenge test for evaluation of cerebrovascular reactivity. (author)

  10. Relationship between lung-to-heart uptake ratio of technetium-99m-tetrofosmin during exercise myocardial single photon emission computed tomographic imaging and the number of diseased coronary arteries in patients with effort angina pectoris without myocardial infarction

    International Nuclear Information System (INIS)

    Okajima, Toshiya; Ueshima, Kenji; Nishiyama, Osamu; Ogawa, Muneyoshi; Ohuchi, Mami; Saitoh, Masahiko; Hiramori, Katsuhiko

    2004-01-01

    Increased lung uptake of thallium-201 in exercise myocardial perfusion imaging is a reliable marker of multivessel disease in patients with ischemic heart disease. This study investigated whether the lung-to-heart uptake ratio with technetium-99m ( 99m Tc)-tetrofosmin also provides valuable information to detect patients with multivessel disease. Fifty-three consecutive patients (35 men, 18 women, mean age 66±11 years; single-vessel disease: 29, double-vessel disease: 16, triple-vessel disease: 8) with stable effort angina pectoris without prior myocardial infarction and 17 control subjects (12 men, 5 women, mean age 62±9 years) underwent exercise myocardial perfusion imaging with 99m Tc-tetrofosmin and coronary angiography in January 2000 to December 2002. The lung-to-heart uptake ratio was calculated on an anterior projection before reconstruction of the exercise single photon emission computed tomographic images. The mean lung-to-heart uptake ratio was 0.34±0.04, 0.38±0.07, 0.41±0.05, and 0.46±0.09, in patients with normal coronary, single-vessel disease, double-vessel disease, and triple-vessel disease, respectively. Significantly higher lung-to-heart uptake ratio was associated with more diseased vessels (p 99m Tc-tetrofosmin can provide clinically useful information to detect multivessel disease in patients with ischemic heart disease. (author)

  11. Synthesis, Characterization, and Preclinical Evaluation of (99m)Tc-Labeled Macrobicyclic and Tricyclic Chelators as Single Photon Emission Computed Tomography Tracer.

    Science.gov (United States)

    Yadav, Neelam; Chuttani, Krishna; Mishra, Anil K; Singh, Bachcha

    2016-05-01

    The novel tetraaza macrobicyclic chelator 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-2,10-dione (TBPD) and pentaaza macrotricyclic chelator 9-oxa-3,6,12,15,21-pentaazatricyclo[15,3,2,1]trieicos-1(21),17,19-triene-2,7,11,16-tetradione (OPTT) were synthesized, characterized, and radiolabeled with (99m)Tc to produce (99m)Tc-TBPD and (99m)Tc-OPTT. These radiolabeled complexes were prepared with high radiolabeling yield, radiochemical purity, and good in vitro stability up to 24 h. The labeling efficiency of (99m)Tc-TBPD and (99m)Tc-OPTT was found 98% and 97%. In vitro serum stability of (99m)Tc-TBPD was found to be 95.2%, while that of (99m)Tc-OPTT 94.2% up to 24 h. Blood kinetics experiments of (99m)Tc-labeled complexes showed biphasic pattern of blood clearance. About 99.57 ± 0.89% activity of (99m)Tc-TBPD and 99.42 ± 0.88% activity of (9m)Tc-OPTT were cleared off blood stream at 24 h postadministration. The biological half-life of (99m) Tc-TBPD was observed: t1/2(F) 1 h 5 min and t1/2(S) 12 h and biological half-life of (99m)Tc-OPTT was observed: t1/2(F) 1 h 10 min and t1/2(S) 9 h 50 min, respectively. The biodistribution studies revealed that maximum uptake of (99m)Tc-TBPD was found in liver, concluded that excretory pathway is hepatobiliary, while that of (99m)Tc-OPTT was renal as well as hepatobiliary. The negligible activity observed in stomach confirming the stability of radiolabeled complex in biological milieu. In vitro cytotoxicity study of TBPD and OPTT did not show any considerable antiproliferative activity against cancer cells of human cervical SW756, HeLa, and glioblastoma U-87, U373 cell lines. © 2015 John Wiley & Sons A/S.

  12. Optimisation and validation of a 3D reconstruction algorithm for single photon emission computed tomography by means of GATE simulation platform

    International Nuclear Information System (INIS)

    El Bitar, Ziad

    2006-12-01

    Although time consuming, Monte-Carlo simulations remain an efficient tool enabling to assess correction methods for degrading physical effects in medical imaging. We have optimized and validated a reconstruction method baptized F3DMC (Fully 3D Monte Carlo) in which the physical effects degrading the image formation process were modelled using Monte-Carlo methods and integrated within the system matrix. We used the Monte-Carlo simulation toolbox GATE. We validated GATE in SPECT by modelling the gamma-camera (Philips AXIS) used in clinical routine. Techniques of threshold, filtering by a principal component analysis and targeted reconstruction (functional regions, hybrid regions) were used in order to improve the precision of the system matrix and to reduce the number of simulated photons as well as the time consumption required. The EGEE Grid infrastructures were used to deploy the GATE simulations in order to reduce their computation time. Results obtained with F3DMC were compared with the reconstruction methods (FBP, ML-EM, MLEMC) for a simulated phantom and with the OSEM-C method for the real phantom. Results have shown that the F3DMC method and its variants improve the restoration of activity ratios and the signal to noise ratio. By the use of the grid EGEE, a significant speed-up factor of about 300 was obtained. These results should be confirmed by performing studies on complex phantoms and patients and open the door to a unified reconstruction method, which could be used in SPECT and also in PET. (author)

  13. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  14. Single Photon Sources in Silicon Carbide

    International Nuclear Information System (INIS)

    Brett Johnson

    2014-01-01

    Single photon sources in semiconductors are highly sought after as they constitute the building blocks of a diverse range of emerging technologies such as integrated quantum information processing, quantum metrology and quantum photonics. In this presentation, we show the first observation of single photon emission from deep level defects in silicon carbide (SiC). The single photon emission is photo-stable at room temperature and surprisingly bright. This represents an exciting alternative to diamond color centers since SiC possesses well-established growth and device engineering protocols. The defect is assigned to the carbon vacancy-antisite pair which gives rise to the AB photoluminescence lines. We discuss its photo-physical properties and their fabrication via electron irradiation. Preliminary measurements on 3C SiC nano-structures will also be discussed. (author)

  15. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  16. Usefulness of 99mTc-methoxy-iso-butyl-isonitrile myocardial single photon emission computed tomography during infusion of low-dose dobutamine and nitroglycerin. Evaluation of myocardial viability

    International Nuclear Information System (INIS)

    Yagi, Hidenori

    1995-01-01

    This study evaluated myocardial viability with 99m Tc-methoxy-iso-butyl-isonitrile (MIBI) single photon emission computed tomography (SPECT) during infusion of low-dose of dobutamine (DOB) and nitroglycerin (NTG). The subjects were 13 patients with coronary artery disease associated with wall motion abnormalities. Myocardial SPECT with MIBI was performed during infusion of NTG followed by infusion of DOB. Rest MIBI study was also performed on a separate day. The regional uptake of MIBI was visually evaluated by scoring (from 0=normal to 3=defect) in 9 regions of left ventricular wall in comparison with LVG or echocardiography data. The regional uptake of MIBI was quantitatively evaluated in 33 segments of left ventricular wall by a computer. The uptake of MIBI during infusion of both DOB and NTG was compared with that at rest study in the region of wall motion abnormalities. The mean uptake score of MIBI during infusion of both DOB and NTG and that of MIBI at rest was 1.8 and 2.1, respectively. The uptake of MIBI was significantly improved by infusion of both DOB and NTG (p<0.01). Percent of the peak activity of MIBI during infusion of both DOB and NTG and that of MIBI at rest in the region where the uptake score had been improved was 76.6±12.7% versus 74.0±13.1% (p<0.01). Percent of the peak activity of MIBI in the region where the uptake score had not been improved was 60.1±18.1% versus 60.7±18.7% (NS). Quantitative study also showed a significant improvement of MIBI uptake on the study of DOB and NTG. These results suggest that MIBI SPECT during infusion of both DOB and NTG infusion might be useful for evaluating myocardial viability. (S.Y.)

  17. Single Photon Experiments and Quantum Complementarity

    Directory of Open Access Journals (Sweden)

    Georgiev D. D.

    2007-04-01

    Full Text Available Single photon experiments have been used as one of the most striking illustrations of the apparently nonclassical nature of the quantum world. In this review we examine the mathematical basis of the principle of complementarity and explain why the Englert-Greenberger duality relation is not violated in the configurations of Unruh and of Afshar.

  18. Demonstrating quantum random with single photons

    International Nuclear Information System (INIS)

    Bronner, Patrick; Strunz, Andreas; Meyn, Jan-Peter; Silberhorn, Christine

    2009-01-01

    We present an experiment for education which demonstrates random transmission or reflection of heralded single photons on beam splitters. With our set-up, we can realize different quantum random experiments by appropriate settings of polarization rotators. The concept of entanglement is motivated by correlated randomness. The experiments are suitable for undergraduate education and are available as interactive screen experiments.

  19. Interactive Screen Experiments with Single Photons

    Science.gov (United States)

    Bronner, Patrick; Strunz, Andreas; Silberhorn, Christine; Meyn, Jan-Peter

    2009-01-01

    Single photons are used for fundamental quantum physics experiments as well as for applications. Originally being a topic of advance courses, such experiments are increasingly a subject of undergraduate courses. We provide interactive screen experiments (ISE) for supporting the work in a real laboratory, and for students who do not have access to…

  20. Coherent single-photon absorption by single emitters coupled to one-dimensional nanophotonic waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yuntian; Wubs, Martijn; Moerk, Jesper [DTU Fotonik, Department of Photonics Engineering, Oersteds Plads, DK-2800 Kgs Lyngby (Denmark); Koenderink, A Femius, E-mail: yche@fotonik.dtu.dk [Center for Nanophotonics, FOM Institute for Atomic and Molecular Physics (AMOLF), Science Park 104, 1098 XG Amsterdam (Netherlands)

    2011-10-15

    We study the dynamics of single-photon absorption by a single emitter coupled to a one-dimensional waveguide that simultaneously provides channels for spontaneous emission (SE) decay and a channel for the input photon. We have developed a time-dependent theory that allows us to specify any input single-photon wavepacket guided by the waveguide as the initial condition, and calculate the excitation probability of the emitter, as well as the time evolution of the transmitted and reflected fields. For single-photon wavepackets with a Gaussian spectrum and temporal shape, we obtain analytical solutions for the dynamics of absorption, with maximum atomic excitation {approx}40%. We furthermore propose a terminated waveguide to aid the single-photon absorption. We found that for an emitter placed at an optimal distance from the termination, the maximum atomic excitation due to an incident single-photon wavepacket can exceed 70%. This high value is a direct consequence of the high SE {beta}-factor for emission into the waveguide. Finally, we have also explored whether waveguide dispersion could aid single-photon absorption by pulse shaping. For a Gaussian input wavepacket, we found that the absorption efficiency can be improved by a further 4% by engineering the dispersion. Efficient single-photon absorption by a single emitter has potential applications in quantum communication and quantum computation. (paper)

  1. Relationship between the mismatch of 123I-BMIPP and 201Tl myocardial single-photon emission computed tomography and autonomic nervous system activity in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yamanaka, Hiroyuki; Suzuki, Takeshi; Kishida, Hiroshi; Nagasawa, Koichi; Takano, Teruo

    2006-01-01

    The purpose of this study was to elucidate the relationship between the mismatch of thallium-201 (Tl) and iodine-123-beta-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography (SPECT) and autonomic nervous system activity in myocardial infarction (MI) patients. The subjects were 40 patients (34 males, 6 females) who underwent examinations by 123 I-BMIPP and 201 Tl myocardial SPECT imaging and 24-hour Holter monitoring within a 3-day period 3 weeks after the onset of their first MI. R-R intervals were analyzed every hour over a period of 24 hours by fast Fourier transformation (FFT). High frequency (HF) and low frequency (LF) were defined as markers of cardiac vagal activity in the former and the LF/HF ratio as sympathetic activity. Greater or more extensive decreases in the BMIPP image than that in the Tl image were defined as a positive mismatch. Patients were divided into positive and negative mismatch groups of 20 patients each. There were no significant differences between the 2 groups in age, sex, site of infarction, max CK (creatine kinase), max CK-MB, or left ventricular ejection fraction. The incidences of clinical signs suggesting residual myocardial ischemia were significantly greater in the positive than in the negative mismatch group (P 123 I-BMIPP and 201 Tl myocardial SPECT 3 weeks after a first acute myocardial infarction with uncomplicated moderate or severe heart failure and decreased heart rate variability are related to residual myocardial ischemia. A combined assessment of heart rate variability in 24 hour Holter electrocardiogram (ECG) monitoring and perfusion-metabolism mismatch in 123 I-BMIPP and 201 Tl myocardial SPECT is useful for determining residual myocardial ischemia in the follow-up of those with acute myocardial infarction. (author)

  2. Distribution of Functional Liver Volume in Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus in the 1st Branch and Main Trunk Using Single Photon Emission Computed Tomography—Application to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Akira Ikoma

    2011-10-01

    Full Text Available Purpose: To analyze the distribution of functional liver volume (FLV in the margin volume (MV surrounding hepatocellular carcinoma (HCC with portal vein tumor thrombus (PVTT before radiation therapy (RT and to verify the safety of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B3DCRT by exploring the relation of FLV in MV to radiation-induced liver disease (RILD. Methods and Materials: Clinical target volume (CTV included main tumor and PVTT, and planning target volume (PTV included CTV with a 10 mm margin. MV was defined as PTV–CTV. FLV ratio in MV was calculated as FLV in MV/MV × 100 (%. The two high-dose beams were planned to irradiate FLV as little as possible. Fifty-seven cases of HCC (26/57, 46%; Child–Pugh grade B with PVTT underwent SPECT-B3DCRT which targeted the CTV to a total dose of 45 Gy/18 fractions. The destructive ratio was defined as radiation induced dysfunctional volume/FLV × 100 (%. Results: We observed a significant negative correlation between FLV ratio in MV and CTV (p < 0.001. Three cases with CTVs of 287, 587 and 1184 cm3 experienced transient RILD. The FLV ratio in MV was highest in patients with RILD: nine patients with CTV of 200–300 cm3, three with CTV of 500–600 cm3, and two with CTV of 1100–1200 cm3. The destructive ratio yielded a mean value of 24.2 ± 1.5%. Conclusions: Radiation planning that takes into account the distribution of FLV appears to result in the least possible RILD.

  3. Impact of intracoronary injection of mononuclear bone marrow cells in acute myocardial infarction on left ventricular perfusion and function: a 6-month follow-up gated 99mTc-MIBI single-photon emission computed tomography study

    International Nuclear Information System (INIS)

    Lipiec, Piotr; Krzeminska-Pakula, Maria; Plewka, Michal; Kasprzak, Jaroslaw D.; Kusmierek, Jacek; Plachcinska, Anna; Szuminski, Remigiusz; Robak, Tadeusz; Korycka, Anna

    2009-01-01

    We investigated the impact of intracoronary injection of autologous mononuclear bone marrow cells (BMC) in patients with acute ST elevation myocardial infarction (STEMI) on left ventricular volumes, global and regional systolic function and myocardial perfusion. The study included 39 patients with first anterior STEMI treated successfully with primary percutaneous coronary intervention. They were randomly assigned to the treatment group or the control group in a 2:1 ratio. The patients underwent baseline gated single-photon emission computed tomography (G-SPECT) 3-10 days after STEMI with quantitative and qualitative analysis of left ventricular perfusion and systolic function. On the following day, patients from the BMC treatment group were subjected to bone marrow aspiration, mononuclear BMC isolation and intracoronary injection. No placebo procedure was performed in the control group. G-SPECT was repeated 6 months after STEMI. Baseline and follow-up G-SPECT studies were available for 36 patients. At 6 months in the BMC group we observed a significantly enhanced improvement in the mean extent of the perfusion defect, the left ventricular perfusion score index, the infarct area perfusion score and the infarct area wall motion score index compared to the control group (p=0.01-0.04). However, the changes in left ventricular volume, ejection fraction and the left ventricular wall motion score index as well as the relative changes in the infarct area wall motion score index did not differ significantly between the groups. Intracoronary injection of autologous mononuclear BMC in patients with STEMI improves myocardial perfusion at 6 months. The benefit in infarct area systolic function is less pronounced and there is no apparent improvement of global left ventricular systolic function. (orig.)

  4. Impact of metabolic syndrome and diabetes mellitus on cardiovascular events in coronary artery disease without ischemia on stress thallium-201 single photon emission computed tomography after percutaneous coronary intervention

    International Nuclear Information System (INIS)

    Mori, Takao; Ohashi, Yoshitaka; Ejiri, Junya; Takatsuki, Kiyonobu; Ichikawa, Shinobu; Awano, Kojiro

    2005-01-01

    The metabolic syndrome defined by the National Cholesterol Education Program Adult Treatment Panel III (NCEP ATP III) is a predictor of cardiovascular events. However, the significance of metabolic syndrome for cardiovascular events has been not clarified in Japan. The impact of metabolic syndrome and diabetes mellitus on cardiovascular events was investigated, especially in the high risk group after percutaneous coronary intervention. We studied 456 patients (mean age 63±10 years, range 36-88 years) without ischemia on stress thallium-201 single photon emission computed tomography after percutaneous coronary intervention. The diagnosis of metabolic syndrome was made according to the modified NCEP ATP III criteria. Cardiovascular events were examined for mean 3.7±1.8 years (range 2.0-8.7 years). There were 196 patients without diabetes mellitus or metabolic syndrome (Group D-M-), 89 patients without diabetes mellitus but with metabolic syndrome (Group D-M+), 61 patients with diabetes mellitus but without metabolic syndrome (Group D+M-), and 110 patients with both diabetes mellitus and metabolic syndrome (Group D+M+). The event-free survival curve in Group D-M+ was significantly lower than that in Group D-M- (p<0.05), but not different from that in Group D+M-. The survival curve was markedly lower in Group D+M+ than that in Group D-M+ (p<0.005). The Cox proportional hazard model revealed that diabetes mellitus and metabolic syndrome were independent significant risk factors for events. The diagnosis of metabolic syndrome was helpful for identification of patients with high cardiovascular event rate even in patients after percutaneous coronary intervention. The combination of metabolic syndrome and diabetes mellitus markedly increases the risk for cardiovascular events. (author)

  5. Prognostic value of myocardial perfusion single-photon emission computed tomography for the prediction of future cardiac events in a Japanese population. A middle-term follow-up study

    International Nuclear Information System (INIS)

    Matsumoto, Naoya; Sato, Yuichi; Suzuki, Yasuyuki

    2007-01-01

    The prognostic value of rest 201 Tl/stress 99m Tc-tetrofosmin myocardial perfusion single-photon emission computed tomography (SPECT) for the prediction of future hard cardiac events, including acute myocardial infarction (AMI), unstable angina (UAP) and cardiac death, and the implications for risk stratification has not yet been defined in a Japanese population. The 1,988 patients who underwent rest 201 Tl/stress 99m Tc-tetrofosmin SPECT were identified and followed up for the occurrence of AMI, UAP and cardiac death. The mean follow-up interval was 26.9±15.8 months. The 142 patients were revascularized within 60 days after SPECT and they were censored from the prognostic analysis. Summed stress score (SSS), summed rest score and summed difference score (SDS) were calculated using a 5-point scoring (Normal: 0, No uptake: 4) and a 20-segment model; 22 cases of myocardial infarction, 31 of UAP and 22 cardiac deaths occurred (1.2%, 1.7% and 1.2%, respectively). Multivariate Cox regression analysis showed that hypertension (Wald 6.37, p<0.05) and SDS (Wald 8.77, p<0.01) were independent predictors of AMI and UAP. Advanced age (Wald 16.0, p<0.001), SSS (Wald 10.9, p<0.01) and SDS (Wald 4.58, p<0.05) were independent predictors of cardiac death. Myocardial perfusion SPECT yields prognostic information toward the identification of acute coronary syndrome and cardiac death. (author)

  6. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  7. Reduced regional cerebral blood flow in aged noninsulin-dependent diabetic patients with no history of cerebrovascular disease: evaluation by N-isopropyl-123I-p-iodoamphetamine with single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Wakisaka, M.; Nagamachi, S.; Inoue, K.; Morotomi, Y.; Nunoi, K.; Fujishima, M.

    1990-01-01

    Regional cerebral blood flow was measured using N-isopropyl- 123 I-iodoamphetamine with single-photon emission computed tomography (CT) in 16 aged patients with noninsulin-dependent diabetes mellitus (NIDDM, average age 72.8 years, average fasting plasma glucose 7.7 mmol/L), and 12 nondiabetic subjects (71.6 years, 5.3 mmol/L). None had any history of a cerebrovascular accident. Systolic blood pressure (SBP), total cholesterol, and triglyceride levels did not differ between groups. Areas of hypoperfusion were observed in 14 diabetic patients (12 patients had multiple lesions) and in 6 nondiabetic subjects (3 had multiple lesions). Areas where radioactivity was greater than or equal to 65% of the maximum count of the slice was defined as a region with normal cerebral blood flow (region of interest A, ROI-A), and areas where the count was greater than or equal to 45% were defined as brain tissue regions other than ventricles (ROI-B). The average ROI-A/B ratio of 16 slices was used as a semiquantitative indicator of normal cerebral blood flow throughout the entire brain. Mean ROI-A/B ratio was 49.6 +/- 1.7% in the diabetic group, significantly lower than the 57.9 +/- 1.6% at the nondiabetic group (p less than 0.005). The ratio was inversely correlated with SBP (r = -0.61, p less than 0.05), total cholesterol (r = -0.51, p less than 0.05), and atherogenic index (r = -0.64, p less than 0.01), and was positively correlated with high-density lipoprotein (HDL) cholesterol (r = 0.51, p less than 0.05) in the diabetic, but not the nondiabetic group. These observations suggest that the age-related reduction in cerebral blood flow may be accelerated by a combination of hyperglycemia plus other risk factors for atherosclerosis

  8. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  9. Prediction of left ventricular functional recovery in patients with acute myocardial infarction using single photon emission computed tomography with thallium-201 and iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid

    International Nuclear Information System (INIS)

    Hashimoto, Akiyoshi; Nakata, Tomoaki; Nagao, Kazuhiko

    1995-01-01

    The relationships between myocardial perfusion, fatty acid metabolism, and cardiac function were investigated using dual single photon emission computed tomography (SPECT) with thallium and iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid ( 123 I-BMIPP) during the acute ( 10±1 days) and recovery (60±14 days) phases in 29 patients with acute myocardial infarction. There were 18 patients who underwent successful primary coronary angioplasty (PTCA group) and 11 patients who received conservative therapy (non PTCA group). Thallium and BMIPP uptakes were scored visually by a 4-point system and left ventricular ejection fraction (LVEF) was calculated by radionuclide ventriculography. Although significant positive correlations between thallium and 123 I-BMIPP scores were observed during both phases, BMIPP scores were significantly lower than thallium scores in both acute and recovery phases in the PTCA group. No significant difference in thallium and 123 I-BMIPP scores was observed at the recovery phase in the non PTCA group. LVEF significantly correlated with thallium and 123 I-BMIPP scores in both phases in the PTCA group. Furthermore, the difference between thallium and 123 I-BMIPP scores during the acute phase significantly correlated with the improvement of LVEF during the follow-up period in the PTCA group (y=0.92x-0.77, r=0.65, p 123 I-BMIPP SPECT is increased by reperfusion therapy and persists at least until the recovery phase of myocardial infarction. The recovery of left ventricular function depends on the extent of the mismatched uptake, indicating a predictor for functional recovery following acute myocardial infarction. (author)

  10. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    International Nuclear Information System (INIS)

    Kasama, Shu; Toyama, Takuji; Sato, Makito; Sano, Hirokazu; Ueda, Tetsuya; Sasaki, Toyoshi; Nakahara, Takehiro; Kurabayashi, Masahiko; Higuchi, Tetsuya; Tsushima, Yoshito

    2016-01-01

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m 2 ] undergoing stress 99m Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  11. Clinical studies of cerebral blood flows using single photon emission computed tomography (SPECT), 1; The remote effects of tumors and the adverse effects of radiochemotherapy in the non-affected brain of patients with intracranial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Araki, Yuzo (Gifu Univ. (Japan). Faculty of Medicine)

    1991-01-01

    To examine remote effects of tumors on cerebral blood flow (CBF) and adverse effects of radiochemotherapy on cerebral and cerebellar blood flow (CeBF), mean CBF (mCBF) and mean CeBF (mCeBF) have been studied by single photon emission computed tomography (SPECT) with Xe-133. The subjects were 78 patients with brain tumor, whose ages ranged from 9 to 74 years. Forty normal volunteers served as controls. In the control group, both mCBF and mCeBF were significantly decreased with advancing age. Both ipsilateral and contralateral mCeBFs were significantly decreased in adult patients with bilateral cerebral tumor, as compared with the control group, which was dependent on tumor volume. mCeBF was significantly decreased on the contralataral side than on the ipsilataral side. Similarly, ipsilateral mCBF was significantly lower than that in the control group. Crossed cerebellar diaschisis occurred frequently associated with extensive involvement of tumor into the frontal, parietal, and temporal lobes. In adult patients, a decreased mCBF on the non-affected side before surgery was improved postoperatively. One month after irradiation, it transiently increased and decreased again. Three months after irradiation, mCBF was significantly decreased, as compared with that in the control group. The degree of atrophy and tumor volume influenced mCBF on the non-affected side. These factors were responsible for mCBF in younger patients for the adult group, and in older patients for the child group. For adult patients, radiation dose was also a contributing factor for mCBF. In the group given chemotherapy, mCBF was significantly decreased, as compared with the group without chemotherapy. (N.K.) 102 refs.

  12. Diagnostic value of 123I-betamethyl-p-iodophenyl-pentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) in patients with chest pain. Comparison with rest-stress 99mTc-tetrofosmin SPECT and coronary angiography

    International Nuclear Information System (INIS)

    Kawai, Yuko; Nozaki, Yoichi; Ohkusa, Takanori; Sakurai, Masayuki; Morita, Koichi; Tamaki, Nagara

    2004-01-01

    Basic and clinical studies have indicated that 15-(p-[ 123 I] iodophenyl)-3-(R, S) methylpentadecanoic acid (BMIPP) single photon emission computed tomography (SPECT) can identify ischemic myocardium without evidence of myocardial infarction by the regional decline of tracer uptake. The present study compared BMIPP SPECT with rest-stress myocardial perfusion imaging (MPI) findings and coronary angiography (CAG) in 150 patients with acute chest pain. Patients with acute chest pain who underwent all of the following tests were selected: MPI at rest-stress, BMIPP SPECT at rest and CAG. Organic coronary artery stenosis (≥75%) was observed in 46 patients, 27 patients had total or subtotal coronary occlusion by spasm in the spasm provocation test on CAG and the remaining 77 patients had no significant coronary artery stenosis or spasm. The sensitivity of BMIPP at rest to detect organic stenosis was significantly higher (54%) than that of rest-MPI (33%, p<0.005), but lower than that of stress-MPI (76%, p=0.05). The sensitivity of BMIPP at rest to detect spasm was significantly higher (63%) than that of both rest-MPI (15%; p<0.001) and stress-MPI (19%; p<0.001). Overall, the sensitivity of BMIPP at rest to detect both organic stenosis and spasm was significantly higher (58%) than that of rest-MPI (26%; p<0.001), despite having no significance with that of stress-MPI (55%). The specificity was not significantly different among the three imaging techniques. Resting BMIPP SPECT is an alternative method to stress MPI for identifying patients with not only organic stenosis but also spasm without the need for a stress examination. (author)

  13. Multimodal Imaging of Integrin Receptor-Positive Tumors by Bioluminescence, Fluorescence, Gamma Scintigraphy, and Single-Photon Emission Computed Tomography Using a Cyclic RGD Peptide Labeled with a Near-Infrared Fluorescent Dye and a Radionuclide

    Directory of Open Access Journals (Sweden)

    W. Barry Edwards

    2009-03-01

    Full Text Available Integrins, particularly the αvβ3 heterodimers, play important roles in tumor-induced angiogenesis and invasiveness. To image the expression pattern of the αvβ3 integrin in tumors through a multimodality imaging paradigm, we prepared a cyclic RGDyK peptide analogue (LS308 bearing a tetraazamacrocycle 1,4,7,10-tetraazacyclododecane-N, N′, N″, N‴-tetraacetic acid (DOTA and a lipophilic near-infrared (NIR fluorescent dye cypate. The αvβ3 integrin binding affinity and the internalization properties of LS308 mediated by the αvβ3 integrin in 4t1luc cells were investigated by receptor binding assay and fluorescence microscopy, respectively. The in vivo distribution of 111In-labeled LS308 in a 4t1luc tumor-bearing mouse model was studied by fluorescence, bioluminescence, planar gamma, and single-photon emission computed tomography (SPECT. The results show that LS308 has high affinity for αvβ3 integrin and internalized preferentially via the αvβ3 integrin-mediated endocytosis in 4t1luc cells. We also found that LS308 selectively accumulated in αvβ3-positve tumors in a receptor-specific manner and was visualized by the four imaging methods. Whereas the endogenous bioluminescence imaging identified the ensemble of the tumor tissue, the fluorescence and SPECT methods with the exogenous contrast agent LS308 reported the local expression of αvβ3 integrin. Thus, the multimodal imaging approach could provide important complementary diagnostic information for monitoring the efficacy of new antiangiogenic drugs.

  14. Ultrafast time measurements by time-correlated single photon counting coupled with superconducting single photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Shcheslavskiy, V., E-mail: vis@becker-hickl.de; Becker, W. [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Morozov, P.; Divochiy, A. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Vakhtomin, Yu. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); Smirnov, K. [Scontel, Rossolimo St., 5/22-1, Moscow 119021 (Russian Federation); Moscow State Pedagogical University, 1/1 M. Pirogovskaya St., Moscow 119991 (Russian Federation); National Research University Higher School of Economics, 20 Myasnitskaya St., Moscow 101000 (Russian Federation)

    2016-05-15

    Time resolution is one of the main characteristics of the single photon detectors besides quantum efficiency and dark count rate. We demonstrate here an ultrafast time-correlated single photon counting (TCSPC) setup consisting of a newly developed single photon counting board SPC-150NX and a superconducting NbN single photon detector with a sensitive area of 7 × 7 μm. The combination delivers a record instrument response function with a full width at half maximum of 17.8 ps and system quantum efficiency ∼15% at wavelength of 1560 nm. A calculation of the root mean square value of the timing jitter for channels with counts more than 1% of the peak value yielded about 7.6 ps. The setup has also good timing stability of the detector–TCSPC board.

  15. Angle sensitive single photon avalanche diode

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Changhyuk, E-mail: cl678@cornell.edu; Johnson, Ben, E-mail: bcj25@cornell.edu; Molnar, Alyosha, E-mail: am699@cornell.edu [Electrical and Computer Engineering, Cornell University, Ithaca, New York 14850 (United States)

    2015-06-08

    An ideal light sensor would provide exact information on intensity, timing, location, and angle of incoming photons. Single photon avalanche diodes (SPADs) provide such desired high (single photon) sensitivity with precise time information and can be implemented at a pixel-scale to form an array to extract spatial information. Furthermore, recent work has demonstrated photodiode-based structures (combined with micro-lenses or diffraction gratings) that are capable of encoding both spatial and angular information of incident light. In this letter, we describe the implementation of such a grating structure on SPADs to realize a pixel-scale angle-sensitive single photon avalanche diode (A-SPAD) built in a standard CMOS process. While the underlying SPAD structure provides high sensitivity, the time information of the two layers of diffraction gratings above offers angle-sensitivity. Such a unique combination of SPAD and diffraction gratings expands the sensing dimensions to pave a path towards lens-less 3-D imaging and light-field time-of-flight imaging.

  16. Phonon number measurements using single photon opto-mechanics

    International Nuclear Information System (INIS)

    Basiri-Esfahani, S; Akram, U; Milburn, G J

    2012-01-01

    We describe a system composed of two coupled optical cavity modes with a coupling modulated by a bulk mechanical resonator. In addition, one of the cavity modes is irreversibly coupled to a single photon source. Our scheme is an opto-mechanical realization of the Jaynes–Cummings model where the qubit is a dual rail optical qubit while the bosonic degree of freedom is a matter degree of freedom realized as the bulk mechanical excitation. We show the possibility of engineering phonon number states of the mechanical oscillator in such a system by computing the conditional state of the mechanics after successive photon counting measurements. (paper)

  17. Simultaneous 99mTc and 123I dual-isotope brain striatal phantom single photon emission computed tomography: validation of 99mTc-TRODAT-1 and 123I-IBZM simultaneous dopamine system brain imaging.

    Science.gov (United States)

    Kao, Pan-Fu; Wey, Shiaw-Pyng; Yang, An-Shoei

    2009-11-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)-amino]ethyl]amino]ethanethiolato(3-)-N2,N2',S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine pre- and postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition. A five-compartment brain striatal phantom was filled with 99mTc and/or 123I radioactive solutions with different striatal-to-background ratios, ranging from 3:1 to 9:1. SPECT data were acquired with energy window settings of 15% for the centered window at 140 keV for 99mTc and a 10% asymmetric window at 159 keV for 123I. The experiments were carried out using either individual (99mTc or 123I only) or both radionuclides. The striatal-to-background ratios and energy crossed interference between 99mTc and 123I were calculated. The phantom SPECT images demonstrated that the energy crossed interferences from 123I to 99mTc, and vice versa, were 22 +/- 12.4% and 0.4 +/- 1.0%, respectively. A net interference of 7.1 +/- 4.0% for the counts in the 15% centered 99mTc window can be expected from 123I and a net interference of 1.6 +/- 3.3% for the counts in the 10% asymmetric 123I window was derived from 99mTc. The correlation of striatal-to-background ratios between single isotope and simultaneous dual-isotope was excellent (R2 = 0.99). The imaging parameters used in this simultaneous dualisotope SPECT imaging could be used in future clinical practice for imaging patients with movement disorders by using 99mTc-TRODAT-1 and 123I-IBZM. The striatal-to-background ratios were not affected by the crossed interference between 99mTc and 123I.

  18. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    Directory of Open Access Journals (Sweden)

    Pan-Fu Kao

    2009-11-01

    Full Text Available [2[[2-[[[3-(4-chlorophenyl-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethylamino]ethyl]amino]ethanethiolato(3--N2,N2′,S2,S2]oxo-[1R-exo-exo]-[99mTc]-technetium (99mTc-TRODAT-1 and 123I-iodobenzamide (123I-IBZM are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT 99mTc and 123I data acquisition. A five-compartment brain striatal phantom was filled with 99mTc and/or 123I radioactive solutions with different striatal-to-background ratios, ranging from 3:1 to 9:1. SPECT data were acquired with energy window settings of 15% for the centered window at 140 keV for 99mTc and a 10% asymmetric window at 159 keV for 123I. The experiments were carried out using either individual (99mTc or 123I only or both radionuclides. The striatal-to-background ratios and energy crossed interference between 99mTc and 123I were calculated. The phantom SPECT images demonstrated that the energy crossed interferences from 123I to 99mTc, and vice versa, were 22 ± 12.4% and 0.4 ± 1.0%, respectively. A net interference of 7.1 ± 4.0% for the counts in the 15% centered 99mTc window can be expected from 123I and a net interference of 1.6 ± 3.3% for the counts in the 10% asymmetric 123I window was derived from 99mTc. The correlation of striatal-to-background ratios between single isotope and simultaneous dual-isotope was excellent (R2 = 0.99. The imaging parameters used in this simultaneous dual-isotope SPECT imaging could be used in future clinical practice for imaging patients with movement disorders by using 99mTc-TRODAT-1 and 123I-IBZM. The striatal-to-background ratios were not affected by the crossed interference between 99mTc and 123I.

  19. Effect of collateral circulation on myocardial protection in patients with acute myocardial infarction. Comparison of technetium-99m-tetrofosmin myocardial single photon emission computed tomography and coronary angiography

    International Nuclear Information System (INIS)

    Yoshida, Michi; Kondo, Makoto; Abe, Yoshiteru; Kubota, Tomoyuki; Matsuoka, Ryota; Araki, Makoto; Tanio, Hitoshi; Doyama, Kiyoshi

    2006-01-01

    Evaluation of myocardial blood flow from collateral vessels into the infarct area has been estimated by coronary angiography. In patients with acute myocardial infarction with Thrombolysis in Myocardial Infarction (TIMI) 0 flow, myocardial tracer uptake on single photon emission computed tomography (SPECT) images can predict the collateral blood flow in the infarct area if technetium (Tc)-99m-tetrofosmin was administered before recanalization. The present study investigated whether collateral blood flow evaluated by myocardial scintigraphy is a good predictor of myocardial salvage in patients with acute myocardial infarction. The study group consisted of 30 patients (mean age 65±14 years, 23 males, 7 females) with first acute myocardial infarction and coronary angiography evidence of total occlusion (TIMI 0) within 12 hr after the onset. All patients had one vessel disease related to infarction and TIMI 3 flow after percutaneous coronary intervention (PCI). Tc-99m-tetrofosmin was injected intravenously before the PCI. The regional severity score index (RSSI) was obtained from SPECT using the 17 segment method with the four-point scoring system. Myocardial viability was evaluated by the RSSI obtained from thallium-glucose-insulin infusion SPECT after 1 week and regional wall motion score index obtained from echocardiography during the chronic phase. The patients were divided into two groups according to the angiographic collateral finding. There were no differences in RSSI on thallium-glucose-insulin SPECT and regional wall motion score between the good collateral group (n=8) and poor collateral group (n=22). Myocardial Tc-99m-tetrofosmin RSSI was similar in these groups. On the other hand, the patients were divided according to Tc-99m-tetrofosmin scintigraphic evaluation before PCI. RSSI on thallium-glucose-insulin SPECT was significantly greater (0.7±0.5 vs 1.5±0.4, p<0.01) and regional wall motion score was significantly less (1.46±0.50 vs 2.08±0.78, p<0

  20. Efficacy of iodine-123-15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid single photon emission computed tomography imaging in detecting myocardial ischemia in children with Kawasaki disease

    International Nuclear Information System (INIS)

    Hoshina, Masaru; Shiraishi, Hirohiko; Igarashi, Hiroshi; Kikuchi, Yutaka; Ichihashi, Kou; Momoi, Mariko Y.

    2003-01-01

    To evaluate its efficacy in detecting myocardial ischemia in children, iodine-123-labeled 15-(p-iodophenyl)-3-R,S-methylpentadecanoic acid (BMIPP) myocardial single photon emission computed tomography (SPECT) imaging was performed in 16 pediatric patients with Kawasaki disease (KD, 11 male, 5 female; mean age and range: 13 years 8 months and 8 years 11 months to 17 years 7 months). Five children with chest pain and no cardiac disease were studied as controls (2 male, 3 female; mean age and range: 13 years 4 months and 9 years 4 months to 17 years 11 months). Selective coronary angiography was also performed in the 16 patients to evaluate the location of coronary stenosis and coronary aneurysms. The SPECT images were expressed as polar maps (Bull's eye maps) and the 'defect' area was defined as where the uptake of BMIPP was less than the standardized BMIPP images of the 5 control children. In the 16 patients, 33 segments had coronary aneurysms and 10 (10/33: 30.3%) had significant coronary stenosis on selective coronary angiography. Nine of the 10 (90%) segments with significant coronary stenosis showed a defect on the BMIPP image whereas only 6 of the 23 (26.1%) segments without coronary stenosis showed a defect on BMIPP imaging. The sensitivity of BMIPP SPECT imaging for detection of coronary stenosis was 90% (9/10) and its specificity was 73.9% (17/23), whereas the sensitivity of 201 Tl SPECT imaging was 80% (8/10) and its specificity was 60% (14/23). There was no significant difference between the BMIPP and 201 Tl SPECT images in either the sensitivity or specificity for the detection of coronary stenosis. In the present series, only one case had discordant BMIPP uptake (BMIPP uptake 201 Tl uptake) in which there was a large coronary aneurysm and re-canalization after complete obstruction at segment 1 of the right coronary artery. This discordant BMIPP uptake reflects the possibility of ischemic but viable myocardium after re-canalization of a large aneurysm in

  1. Transmitting more than 10 bit with a single photon

    NARCIS (Netherlands)

    Tentrup, T.B.H.; Hummel, T.; Wolterink, T.A.W.; Uppu, R.; Mosk, Allard; Pinkse, P.W.H.

    2017-01-01

    Encoding information in the position of single photons has no known limits, given infinite resources. Using a heralded single-photon source and a spatial light modulator (SLM), we steer single photons to specific positions in a virtual grid on a large-area spatially resolving photon-counting

  2. Single Photon Double Ionization of Atomic Oxygen

    Science.gov (United States)

    Wickramarathna, Madhushani; Gorczyca, Thomas; Ballance, Connor; Stolte, Wayne

    2017-04-01

    Single photon double ionization cross sections are calculated using an R-matrix with pseudostates (RMPS) method which was recently applied by Gorczyca et al. for the double photoionization of helium. With the convergence of these theoretical calculations for the simple case of helium, we extend this methodology to consider the more complex case of oxygen double photoionization. We compare our calculated results with recent measurements at the Advanced Light Source, as well as earlier experimental measurements. Our RMPS results agree well, qualitatively, with the experimental measurements, but there exist outstanding discrepancies to be addressed. This project is supported by NASA APRA award NNX17AD41G.

  3. Single photon detector with high polarization sensitivity.

    Science.gov (United States)

    Guo, Qi; Li, Hao; You, LiXing; Zhang, WeiJun; Zhang, Lu; Wang, Zhen; Xie, XiaoMing; Qi, Ming

    2015-04-15

    Polarization is one of the key parameters of light. Most optical detectors are intensity detectors that are insensitive to the polarization of light. A superconducting nanowire single photon detector (SNSPD) is naturally sensitive to polarization due to its nanowire structure. Previous studies focused on producing a polarization-insensitive SNSPD. In this study, by adjusting the width and pitch of the nanowire, we systematically investigate the preparation of an SNSPD with high polarization sensitivity. Subsequently, an SNSPD with a system detection efficiency of 12% and a polarization extinction ratio of 22 was successfully prepared.

  4. Changing optical band structure with single photons

    Science.gov (United States)

    Albrecht, Andreas; Caneva, Tommaso; Chang, Darrick E.

    2017-11-01

    Achieving strong interactions between individual photons enables a wide variety of exciting possibilities in quantum information science and many-body physics. Cold atoms interfaced with nanophotonic structures have emerged as a platform to realize novel forms of nonlinear interactions. In particular, when atoms are coupled to a photonic crystal waveguide, long-range atomic interactions can arise that are mediated by localized atom-photon bound states. We theoretically show that in such a system, the absorption of a single photon can change the band structure for a subsequent photon. This occurs because the first photon affects the atoms in the chain in an alternating fashion, thus leading to an effective period doubling of the system and a new optical band structure for the composite atom-nanophotonic system. We demonstrate how this mechanism can be engineered to realize a single-photon switch, where the first incoming photon switches the system from being highly transmissive to highly reflective, and analyze how signatures can be observed via non-classical correlations of the outgoing photon field.

  5. Sub-megahertz linewidth single photon source

    Directory of Open Access Journals (Sweden)

    Markus Rambach

    2016-12-01

    Full Text Available We report 100% duty cycle generation of sub-MHz single photon pairs at the rubidium D1 line using cavity-enhanced spontaneous parametric downconversion. The temporal intensity cross correlation function exhibits a bandwidth of 666±16 kHz for the single photons, an order of magnitude below the natural linewidth of the target transition. A half-wave plate inside our cavity helps to achieve triple resonance between pump, signal, and idler photon, reducing the bandwidth and simplifying the locking scheme. Additionally, stabilisation of the cavity to the pump frequency enables the 100% duty cycle. The quantum nature of the source is confirmed by the idler-triggered second-order autocorrelation function at τ=0 to be gs,s(2(0= 0.016±0.002 for a heralding rate of 5 kHz. The generated photons are well-suited for storage in quantum memory schemes with sub-natural linewidths, such as gradient echo memories.

  6. Impact of Single-Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) and Positron Emission Tomography/Computed Tomography (PET/CT) in the Diagnosis of Traumatic Brain Injury (TBI): Case Report.

    Science.gov (United States)

    Molina-Vicenty, Irma L; Santiago-Sánchez, Michelaldemar; Vélez-Miró, Iván; Motta-Valencia, Keryl

    2016-09-01

    Traumatic brain injury (TBI) is defined as damage to the brain resulting from an external force. TBI, a global leading cause of death and disability, is associated with serious social, economic, and health problems. In cases of mild-to-moderate brain damage, conventional anatomical imaging modalities may or may not detect the cascade of metabolic changes that have occurred or are occurring at the intracellular level. Functional nuclear medicine imaging and neurophysiological parameters can be used to characterize brain damage, as the former provides direct visualization of brain function, even in the absence of overt behavioral manifestations or anatomical findings. We report the case of a 30-year-old Hispanic male veteran who, after 2 traumatic brain injury events, developed cognitive and neuropsychological problems with no clear etiology in the presence of negative computed tomography (CT) findings.

  7. Circuit electromechanics with single photon strong coupling

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Zheng-Yuan, E-mail: zyxue@scnu.edu.cn; Yang, Li-Na [Guangdong Provincial Key Laboratory of Quantum Engineering and Quantum Materials, and School of Physics and Telecommunication Engineering, South China Normal University, Guangzhou 510006 (China); Zhou, Jian, E-mail: jianzhou8627@163.com [Department of Electronic Communication Engineering, Anhui Xinhua University, Hefei 230088 (China); Guangdong Provincial Key Laboratory of Quantum Engineering and Quantum Materials, and School of Physics and Telecommunication Engineering, South China Normal University, Guangzhou 510006 (China)

    2015-07-13

    In circuit electromechanics, the coupling strength is usually very small. Here, replacing the capacitor in circuit electromechanics by a superconducting flux qubit, we show that the coupling among the qubit and the two resonators can induce effective electromechanical coupling which can attain the strong coupling regime at the single photon level with feasible experimental parameters. We use dispersive couplings among two resonators and the qubit while the qubit is also driven by an external classical field. These couplings form a three-wave mixing configuration among the three elements where the qubit degree of freedom can be adiabatically eliminated, and thus results in the enhanced coupling between the two resonators. Therefore, our work constitutes the first step towards studying quantum nonlinear effect in circuit electromechanics.

  8. Single photon imaging. New instrumentation and techniques

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.

    1981-01-01

    The performance of Anger scintillation cameras continues to be enhanced through a series of small improvements which result in significantly better imaging characteristics. The most recent changes in camera design consist of: (1) the introduction of photomultipliers with better photocathode and electron collection efficiencies, (2) the use of thinner (3/8 or 1/4 in) crystals giving slightly better intrinsic resolution for low gamma-ray energies, (3) inclusion of a spatially varying energy window to compensate for variations of light collection efficiency, (4) event-by-event, real-time distortion removal for uniformity correction, and (5) introduction of new methods to improve the count-rate capability. Whereas some of these improvements are due to better understanding of the fundamentals of camera design, others are the result of technological advances in electronic components such as analogue-to-digital converters, microprocessors and high-density digital memories. The development of single photon tomography has developed along two parallel paths. Multipinhole and rotating slant-hole collimator attachments provide some degree of longitudinal tomography, and are currently being applied to cardiac imaging. At the same time rotating camera systems capable of transverse as well as longitudinal imaging are being refined technically and evaluated clinically. Longitudinal tomography is of limited use in quantitative studies and is likely to be an interim solution to three-dimensional imaging. Rotating camera systems, on the other hand, not only provide equal resolution in all three dimensions but are also capable of providing quantitative accuracy. This is the result of progress in attenuation correction and the design of special collimators. Single photon tomography provides a small but noticeable improvement in diagnostic accuracy which is likely to result in widespread use of rotating camera systems in the future

  9. Single-Photon Routing for a L-Shaped Channel

    Science.gov (United States)

    Yang, Xiong; Hou, Jiao-Jiao; Wu, Chun

    2018-02-01

    We have investigated the transport properties of a single photon scattered by a two-level atom embedded in a L-shaped waveguide, which is made of two one-dimensional (1D) semi-infinite coupled-resonator waveguides (CRWs). Single photons can be directed from one CRW to the other due to spontaneous emission of the atom. The result shows that the spontaneous emission of the TLS still routes single photon from one CRW to the other; the boundary existing makes the probability of finding single photon in a CRW could reach one. Our the scheme is helpful to construct a ring quantum networks.

  10. Characteristics of a single photon emission tomography system with a wide field gamma camera

    International Nuclear Information System (INIS)

    Mathonnat, F.; Soussaline, F.; Todd-Pokropek, A.E.; Kellershohn, C.

    1979-01-01

    This text summarizes a work study describing the imagery possibilities of a single photon emission tomography system composed of a conventional wide field gamma camera, connected to a computer. The encouraging results achieved on the various phantoms studied suggest a significant development of this technique in clinical work in Nuclear Medicine Departments [fr

  11. Single-photon emission tomography and cerebral blood flow

    International Nuclear Information System (INIS)

    Celsis, P.; Chan, M.; Marc-Vergnes, J.P.; Sveinsdottir, E.; Goldman, T.G.; Henriksen, L.; Paulson, O.B.; Stokely, E.M.; Lassen, N.A.

    1982-01-01

    This paper illustrates the capabilities of single-photon emission tomography in imaging local cerebral blood flows in man. The results purport the conclusion that a fairly good improvement has been achieved when compared to stationary detectors and that single-photon emission tomography is a well-suited tool for studying cerebral hemodynamics, especially within the framework of clinical studies [fr

  12. Interactive reconstruction in single-photon tomography

    International Nuclear Information System (INIS)

    Miller, T.R.; Wallis, J.W.; Wilson, A.D.

    1989-01-01

    A new method is described to allow interactive selection of the reconstruction filter at the time of interpretation of images from single-photon tomography. In the filtered back projection algorithm, the only part of the reconstruction process requiring user interaction is the selection of the window function. Since the ramp and window filters have different purposes, they can be separated, placing the window at the end of the reconstruction process as a three-dimensional filter. All stages of reconstruction except the window filtering are performed before the physician begins to interpret the study. The three-dimensional filtering is performed very rapidly with use of the Chebyshev convolution algorithm. A 64 x 64 x 64 pixel cube of data is filtered in 13-33 s using filters of 3-11 lengths. Smaller volumes of image data can be filtered in less than 1 s; thus, the user can interactively choose any desired filter for a given tomographic study at the time of interpretation of the images. (orig.)

  13. A scanner for single photon emission tomography

    International Nuclear Information System (INIS)

    Smith, D.B.; Cumpstey, D.E.; Evans, N.T.S.; Coleman, J.D.; Ettinger, K.V.; Mallard, J.R.

    1982-01-01

    The technique of single photon ECT has now been available for some eighteen years, but has yet still to be exploited fully. The difficulties of doing this lie in the need for gathering data of sufficiently good statistical accuracy in a reasonable counting time, in the uniformity of detector sensitivity, and in the means for correcting the image satisfactorily for photon attenuation within the body. The relative ease with which a general purpose gamma camera can be adapted to give rotation around the patient makes this an attractive practical approach to the problem. However, the sensitivity of gamma cameras over their field of view is by no means uniform, and their sensitivity is less good than that of purpose-designed scanners when no more than about ten sections through the body are required. There is therefore a need to assess the clinical usefulness of a whole body tomographic scanner of high sensitivity and uniformity. Such a machine is the Aberdeen Section Scanner Mark II described

  14. Single photon imaging at ultra-high resolution

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, R. [INFN sez. Pisa, Pisa (Italy); Spandre, G. [INFN sez. Pisa, Pisa (Italy)], E-mail: Gloria.Spandre@pi.infn.it; Minuti, M.; Brez, A.; Baldini, L.; Latronico, L.; Omodei, N.; Sgro, C.; Bregeon, J.; Razzano, M.; Pinchera, M. [INFN sez. Pisa, Pisa (Italy); Tremsin, A.; McPhate, J.; Vallerga, J.V.; Siegmund, O. [SSL, Berkeley (United States)

    2008-06-11

    We present a detection system capable of imaging both single photon/positive ion and multiple coincidence photons/positive ions with extremely high spatial resolution. In this detector the photoelectrons excited by the incoming photons are multiplied by microchannel plate(s) (MCP). The process of multiplication is spatially constrained within an MCP pore, which can be as small as 4 {mu}m for commercially available MCPs. An electron cloud originated by a single photoelectron is then encoded by a pixellated custom analog ASIC consisting of 105 K charge sensitive pixels of 50 {mu}m in size arranged on a hexagonal grid. Each pixel registers the charge with an accuracy of <100 electrons rms. Computation of the event centroid from the readout charges results in an accurate event position. A large number of simultaneous photons spatially separated by {approx}0.4 mm can be detected simultaneously allowing multiple coincidence operation for the experiments where a large number of incoming photons/positive ions have to be detected simultaneously. The experimental results prove that the spatial resolution of the readout system itself is {approx}3 {mu}m FWHM enabling detection resolution better than 6 {mu}m for the small pore MCPs. An attractive feature of the detection system is its capability to register the timing of each incoming photon/positive ion (in single photon detection mode) or of the first incoming particle (for the multiple coincidence detection) with an accuracy of {approx}130 ps FWHM. There is also virtually no dark count noise in the detection system making it suitable for low count rate applications.

  15. Effect of temperature and phonons on the spectral properties of a multi-level semiconductor quantum dot single-photon source

    DEFF Research Database (Denmark)

    Nielsen, Per Kær; Nielsen, Torben Roland; Lodahl, Peter

    2009-01-01

    Since it was realized that efficient quantum computing can be performed using single photons and standard linear optics elements, immense international research activity has been aimed at developing semiconductor quantum dot (QD) single-photon sources (SPS). In order to optimise the design of SPS...... us to study complicated multi-level QDs, not possible within the commonly used independent boson model (IBM)....

  16. CeB6 Sensor for Thermoelectric Single-Photon Detector

    Directory of Open Access Journals (Sweden)

    Armen KUZANIAN

    2015-08-01

    Full Text Available Interest in single-photon detectors has recently sharply increased. The most developed single-photon detectors are currently based on superconductors. Following the theory, thermoelectric single-photon detectors can compete with superconducting detectors. The operational principle of thermoelectric detector is based on photon absorption by absorber as a result of which a temperature gradient is generated across the sensor. In this work we present the results of computer modeling of heat distribution processes after absorption of a photon of 1 keV - 1 eV energy in different areas of the absorber for different geometries of tungsten absorber and cerium hexaboride sensor. The time dependence of the temperature difference between the ends of the thermoelectric sensor and electric potential appearing across the sensor are calculated. The results of calculations show that it is realistic to detect single photons from IR to X-ray and determine their energy. Count rates up to hundreds gigahertz can be achieved.

  17. Direct detection of a single photon by humans

    Science.gov (United States)

    Tinsley, Jonathan N.; Molodtsov, Maxim I.; Prevedel, Robert; Wartmann, David; Espigulé-Pons, Jofre; Lauwers, Mattias; Vaziri, Alipasha

    2016-01-01

    Despite investigations for over 70 years, the absolute limits of human vision have remained unclear. Rod cells respond to individual photons, yet whether a single-photon incident on the eye can be perceived by a human subject has remained a fundamental open question. Here we report that humans can detect a single-photon incident on the cornea with a probability significantly above chance. This was achieved by implementing a combination of a psychophysics procedure with a quantum light source that can generate single-photon states of light. We further discover that the probability of reporting a single photon is modulated by the presence of an earlier photon, suggesting a priming process that temporarily enhances the effective gain of the visual system on the timescale of seconds. PMID:27434854

  18. Entanglement and quantum superposition induced by a single photon

    Science.gov (United States)

    Lü, Xin-You; Zhu, Gui-Lei; Zheng, Li-Li; Wu, Ying

    2018-03-01

    We predict the occurrence of single-photon-induced entanglement and quantum superposition in a hybrid quantum model, introducing an optomechanical coupling into the Rabi model. Originally, it comes from the photon-dependent quantum property of the ground state featured by the proposed hybrid model. It is associated with a single-photon-induced quantum phase transition, and is immune to the A2 term of the spin-field interaction. Moreover, the obtained quantum superposition state is actually a squeezed cat state, which can significantly enhance precision in quantum metrology. This work offers an approach to manipulate entanglement and quantum superposition with a single photon, which might have potential applications in the engineering of new single-photon quantum devices, and also fundamentally broaden the regime of cavity QED.

  19. Modeling and Development of Superconducting Nanowire Single Photon Detectors

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a research project as the central component of a Ph.D. program focused on the device physics of superconducting nanowire single photon...

  20. Ultrafast electrical control of a resonantly driven single photon source

    International Nuclear Information System (INIS)

    Cao, Y.; Bennett, A. J.; Ellis, D. J. P.; Shields, A. J.; Farrer, I.; Ritchie, D. A.

    2014-01-01

    We demonstrate generation of a pulsed stream of electrically triggered single photons in resonance fluorescence, by applying high frequency electrical pulses to a single quantum dot in a p-i-n diode under resonant laser excitation. Single photon emission was verified, with the probability of multiple photon emission reduced to 2.8%. We show that despite the presence of charge noise in the emission spectrum of the dot, resonant excitation acts as a “filter” to generate narrow bandwidth photons

  1. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    Science.gov (United States)

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  2. Proposal for automated transformations on single-photon multipath qudits

    Science.gov (United States)

    Baldijão, R. D.; Borges, G. F.; Marques, B.; Solís-Prosser, M. A.; Neves, L.; Pádua, S.

    2017-09-01

    We propose a method for implementing automated state transformations on single-photon multipath qudits encoded in a one-dimensional transverse spatial domain. It relies on transferring the encoding from this domain to the orthogonal one by applying a spatial phase modulation with diffraction gratings, merging all the initial propagation paths by using a stable interferometric network, and filtering out the unwanted diffraction orders. The automation feature is attained by utilizing a programmable phase-only spatial light modulator (SLM) where properly designed diffraction gratings displayed on its screen will implement the desired transformations, including, among others, projections, permutations, and random operations. We discuss the losses in the process which is, in general, inherently nonunitary. Some examples of transformations are presented and, considering a realistic scenario, we analyze how they will be affected by the pixelated structure of the SLM screen. The method proposed here enables one to implement much more general transformations on multipath qudits than is possible with a SLM alone operating in the diagonal basis of which-path states. Therefore, it will extend the range of applicability for this encoding in high-dimensional quantum information and computing protocols as well as fundamental studies in quantum theory.

  3. Single photon sources with single semiconductor quantum dots

    Science.gov (United States)

    Shan, Guang-Cun; Yin, Zhang-Qi; Shek, Chan Hung; Huang, Wei

    2014-04-01

    In this contribution, we briefly recall the basic concepts of quantum optics and properties of semiconductor quantum dot (QD) which are necessary to the understanding of the physics of single-photon generation with single QDs. Firstly, we address the theory of quantum emitter-cavity system, the fluorescence and optical properties of semiconductor QDs, and the photon statistics as well as optical properties of the QDs. We then review the localization of single semiconductor QDs in quantum confined optical microcavity systems to achieve their overall optical properties and performances in terms of strong coupling regime, efficiency, directionality, and polarization control. Furthermore, we will discuss the recent progress on the fabrication of single photon sources, and various approaches for embedding single QDs into microcavities or photonic crystal nanocavities and show how to extend the wavelength range. We focus in particular on new generations of electrically driven QD single photon source leading to high repetition rates, strong coupling regime, and high collection efficiencies at elevated temperature operation. Besides, new developments of room temperature single photon emission in the strong coupling regime are reviewed. The generation of indistinguishable photons and remaining challenges for practical single-photon sources are also discussed.

  4. Investigating and Improving Student Understanding of Quantum Mechanics in the Context of Single Photon Interference

    Science.gov (United States)

    Marshman, Emily; Singh, Chandralekha

    2017-01-01

    Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the…

  5. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  6. Single-photon generator for optical telecommunication wavelength

    International Nuclear Information System (INIS)

    Usuki, T; Sakuma, Y; Hirose, S; Takemoto, K; Yokoyama, N; Miyazawa, T; Takatsu, M; Arakawa, Y

    2006-01-01

    We report on the generation of single-photon pulses from a single InAs/InP quantum dot in telecommunication bands (1.3-1.55 μm: higher transmittance through an optical fiber). First we prepared InAs quantum dots on InP (0 0 1) substrates in a low-pressure MOCVD by using a so-called InP 'double-cap' procedure. The quantum dots have well-controlled photo emission wavelength in the telecommunication bands. We also developed a single-photon emitter in which quantum dots were embedded. Numerical simulation designed the emitter to realize efficient injection of the emitted photons into a single-mode optical fiber. Using a Hanbury-Brown and Twiss technique has proved that the photons through the fiber were single photons

  7. Single-photon light detection with transition-edge sensors

    International Nuclear Information System (INIS)

    Rajteri, M.; Taralli, E.; Portesi, C.; Monticone, E.

    2008-01-01

    Transition-Edge Sensors (TESs) are micro calorimeters that measure the energy of incident single-photons by the resistance increase of a superconducting film biased within the superconducting-to-normal transition. TES are able to detect single photons from x-ray to IR with an intrinsic energy resolution and photon-number discrimination capability. Metrological, astronomical and quantum communication applications are the fields where these properties can be particularly important. In this work, we report about characterization of different TESs based on Ti films. Single-photons have been detected from 200 nm to 800 nm working at T c ∼ 100 m K. Using a pulsed laser at 690 nm we have demonstrated the capability to resolve up to five photons.

  8. Preparation and tomographic reconstruction of an arbitrary single-photon path qubit

    International Nuclear Information System (INIS)

    Baek, So-Young; Kim, Yoon-Ho

    2011-01-01

    We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. The arbitrary single-photon path qubit is prepared losslessly by passing the heralded single-photon state from spontaneous parametric down-conversion through variable beam splitter. Quantum state tomography of the single-photon path qubit is implemented by introducing path-projection measurements based on the first-order single-photon quantum interference. Using the state preparation and path-projection measurements methods for the single-photon path qubit, we demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity. -- Highlights: → We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. → We implement path-projection measurements based on the first-order single-photon quantum interference. → We demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity.

  9. Streak camera imaging of single photons at telecom wavelength

    Science.gov (United States)

    Allgaier, Markus; Ansari, Vahid; Eigner, Christof; Quiring, Viktor; Ricken, Raimund; Donohue, John Matthew; Czerniuk, Thomas; Aßmann, Marc; Bayer, Manfred; Brecht, Benjamin; Silberhorn, Christine

    2018-01-01

    Streak cameras are powerful tools for temporal characterization of ultrafast light pulses, even at the single-photon level. However, the low signal-to-noise ratio in the infrared range prevents measurements on weak light sources in the telecom regime. We present an approach to circumvent this problem, utilizing an up-conversion process in periodically poled waveguides in Lithium Niobate. We convert single photons from a parametric down-conversion source in order to reach the point of maximum detection efficiency of commercially available streak cameras. We explore phase-matching configurations to apply the up-conversion scheme in real-world applications.

  10. Nanofabrication of Plasmonic Circuits Containing Single Photon Sources

    DEFF Research Database (Denmark)

    Siampour, Hamidreza; Kumar, Shailesh; Bozhevolnyi, Sergey I.

    2017-01-01

    Nanofabrication of photonic components based on dielectric loaded surface plasmon polariton waveguides (DLSPPWs) excited by single nitrogen vacancy (NV) centers in nanodiamonds is demonstrated. DLSPPW circuits are built around NV containing nanodiamonds, which are certified to be single-photon...... emitters, using electron-beam lithography of hydrogen silsesquioxane (HSQ) resist on silver-coated silicon substrates. A propagation length of 20 ± 5 μm for the NV single-photon emission is measured with DLSPPWs. A 5-fold enhancement in the total decay rate, and 58% coupling efficiency to the DLSPPW mode...

  11. Optimization of time-correlated single photon counting spectrometer

    International Nuclear Information System (INIS)

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  12. Photon statistics characterization of a single-photon source

    International Nuclear Information System (INIS)

    Alleaume, R; Treussart, F; Courty, J-M; Roch, J-F

    2004-01-01

    In a recent experiment, we reported the time-domain intensity noise measurement of a single-photon source relying on single-molecule fluorescence control. In this paper, we present data processing starting from photocount timestamps. The theoretical analytical expression of the time-dependent Mandel parameter Q(T) of an intermittent single-photon source is derived from ON↔OFF dynamics. Finally, source intensity noise analysis, using the Mandel parameter, is quantitatively compared with the usual approach relying on the time autocorrelation function, both methods yielding the same molecular dynamical parameters

  13. Single-photon interference experiment for high schools

    Science.gov (United States)

    Bondani, Maria

    2014-07-01

    We follow the reductio ad absurdum reasoning described in the book "Sneaking a Look at God's Cards" by Giancarlo Ghirardi to demonstrate the wave-particle duality of light in a Mach-Zehnder interferometric setup analog to the conventional Young double-slit experiment. We aim at showing the double nature of light by measuring the existence of interference fringes down to the single-photon level. The setup includes a strongly attenuated laser, polarizing beam splitters, half-waveplates, polarizers and single-photon detectors.

  14. Stable single-photon source in the near infrared

    International Nuclear Information System (INIS)

    Gaebel, T; Popa, I; Gruber, A; Domhan, M; Jelezko, F; Wrachtrup, J

    2004-01-01

    Owing to their unsurpassed photostability, defects in solids may be ideal candidates for single-photon sources. Here we report on generation of single photons by optical excitation of a yet unexplored defect in diamond, the nickel-nitrogen complex (NE8) centre. The most striking feature of the defect is its emission bandwidth of 1.2 nm at room temperature. The emission wavelength of the defect is around 800 nm, which is suitable for telecom fibres. In addition, in this spectral region little background light from the diamond bulk material is detected. Consequently, a high contrast in antibunching measurements is achieved

  15. New Generation of Superconducting Nanowire Single-Photon Detectors

    Directory of Open Access Journals (Sweden)

    Goltsman G.N.

    2015-01-01

    Full Text Available We present an overview of recent results for new generation of infrared and optical superconducting nanowire single-photon detectors (SNSPDs that has already demonstrated a performance that makes them devices-of-choice for many applications. SNSPDs provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, SNSPDs are also compatible with an integrated optical platform as a crucial requirement for applications in emerging quantum photonic technologies. By embedding SNSPDs in nanophotonic circuits we realize waveguide integrated single photon detectors which unite all desirable detector properties in a single device.

  16. Deterministic and robust generation of single photons from a single quantum dot with 99.5% indistinguishability using adiabatic rapid passage.

    Science.gov (United States)

    Wei, Yu-Jia; He, Yu-Ming; Chen, Ming-Cheng; Hu, Yi-Nan; He, Yu; Wu, Dian; Schneider, Christian; Kamp, Martin; Höfling, Sven; Lu, Chao-Yang; Pan, Jian-Wei

    2014-11-12

    Single photons are attractive candidates of quantum bits (qubits) for quantum computation and are the best messengers in quantum networks. Future scalable, fault-tolerant photonic quantum technologies demand both stringently high levels of photon indistinguishability and generation efficiency. Here, we demonstrate deterministic and robust generation of pulsed resonance fluorescence single photons from a single semiconductor quantum dot using adiabatic rapid passage, a method robust against fluctuation of driving pulse area and dipole moments of solid-state emitters. The emitted photons are background-free, have a vanishing two-photon emission probability of 0.3% and a raw (corrected) two-photon Hong-Ou-Mandel interference visibility of 97.9% (99.5%), reaching a precision that places single photons at the threshold for fault-tolerant surface-code quantum computing. This single-photon source can be readily scaled up to multiphoton entanglement and used for quantum metrology, boson sampling, and linear optical quantum computing.

  17. Quantum optics. All-optical routing of single photons by a one-atom switch controlled by a single photon.

    Science.gov (United States)

    Shomroni, Itay; Rosenblum, Serge; Lovsky, Yulia; Bechler, Orel; Guendelman, Gabriel; Dayan, Barak

    2014-08-22

    The prospect of quantum networks, in which quantum information is carried by single photons in photonic circuits, has long been the driving force behind the effort to achieve all-optical routing of single photons. We realized a single-photon-activated switch capable of routing a photon from any of its two inputs to any of its two outputs. Our device is based on a single atom coupled to a fiber-coupled, chip-based microresonator. A single reflected control photon toggles the switch from high reflection (R ~ 65%) to high transmission (T ~ 90%), with an average of ~1.5 control photons per switching event (~3, including linear losses). No additional control fields are required. The control and target photons are both in-fiber and practically identical, making this scheme compatible with scalable architectures for quantum information processing. Copyright © 2014, American Association for the Advancement of Science.

  18. The Heisenberg picture for single photon states

    International Nuclear Information System (INIS)

    Pienaar, Jacques; Myers, Casey; Ralph, Timothy C.

    2011-01-01

    In the context of quantum field theory, the Heisenberg picture has a distinct advantage over the Schrodinger picture because the Schrodinger picture requires us to transform the vacuum state itself, which can be intractable in the case of non-inertial reference frames, whereas the Heisenberg picture allows us to keep the same vacuum state and only transform the operators. However, the Heisenberg calculation requires the operators to already be expressed as a function of creation and annihilation operators acting on the original vacuum, whereas calculations in quantum information and quantum computation use operators that act on qubit states, necessarily containing particles. The relationship between the operators acting on these states and the operators acting on the vacuum state has remained elusive. We derive such an expression using an explicit model for single-particle production from the vacuum.

  19. Waveguide superconducting single-photon autocorrelators for quantum photonic applications

    NARCIS (Netherlands)

    Sahin, D.; Gaggero, A.; Frucci, G.; Jahanmirinejad, S.; Sprengers, J.P.; Mattioli, F.; Leoni, R.; Beetz, J.; Lermer, M.; Kamp, M.; Höfling, S.; Fiore, A.; Hasan, Z.U.; Hemmer, P.R.; Lee, H.; Santori, C.M.

    2013-01-01

    We report a novel component for integrated quantum photonic applications, a waveguide single-photon autocorrelator. It is based on two superconducting nanowire detectors patterned onto the same GaAs ridge waveguide. Combining the electrical output of the two detectors in a correlation card enables

  20. Deterministic teleportation using single-photon entanglement as a resource

    DEFF Research Database (Denmark)

    Björk, Gunnar; Laghaout, Amine; Andersen, Ulrik L.

    2012-01-01

    We outline a proof that teleportation with a single particle is, in principle, just as reliable as with two particles. We thereby hope to dispel the skepticism surrounding single-photon entanglement as a valid resource in quantum information. A deterministic Bell-state analyzer is proposed which...

  1. Waveguide-Coupled Superconducting Nanowire Single-Photon Detectors

    Science.gov (United States)

    Beyer, Andrew D.; Briggs, Ryan M.; Marsili, Francesco; Cohen, Justin D.; Meenehan, Sean M.; Painter, Oskar J.; Shaw, Matthew D.

    2015-01-01

    We have demonstrated WSi-based superconducting nanowire single-photon detectors coupled to SiNx waveguides with integrated ring resonators. This photonics platform enables the implementation of robust and efficient photon-counting detectors with fine spectral resolution near 1550 nm.

  2. High brightness single photon sources based on photonic wires

    DEFF Research Database (Denmark)

    Claudon, J.; Bleuse, J.; Bazin, M.

    2009-01-01

    We present a novel single-photon-source based on the emission of a semiconductor quantum dot embedded in a single-mode photonic wire. This geometry ensures a very large coupling (> 95%) of the spontaneous emission to the guided mode. Numerical simulations show that a photon collection efficiency...

  3. Design and characterization of single photon avalanche diodes arrays

    Science.gov (United States)

    Neri, L.; Tudisco, S.; Lanzanò, L.; Musumeci, F.; Privitera, S.; Scordino, A.; Condorelli, G.; Fallica, G.; Mazzillo, M.; Sanfilippo, D.; Valvo, G.

    2010-05-01

    During the last years, in collaboration with ST-Microelectronics, we developed a new avalanche photo sensor, single photon avalanche diode (SPAD) see Ref.[S. Privitera, et al., Sensors 8 (2008) 4636 [1];S. Tudisco et al., IEEE Sensors Journal 8 (2008) 1324 [2

  4. Single-photon source engineering using a Modal Method

    DEFF Research Database (Denmark)

    Gregersen, Niels

    Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined as the num...... nanowire SPSs...

  5. Single-photon generation with InAs quantum dots

    International Nuclear Information System (INIS)

    Santori, Charles; Fattal, David; Vuckovic, Jelena; Solomon, Glenn S; Yamamoto, Yoshihisa

    2004-01-01

    Single-photon generation using InAs quantum dots in pillar microcavities is described. The effects on performance of the excitation wavelength and polarization, and the collection bandwidth and polarization, are studied in detail. The efficiency and photon state purity of these devices have been measured, and issues affecting these parameters are discussed. Prospects for improved devices are also discussed

  6. Single-photon production at the CERN ISR

    International Nuclear Information System (INIS)

    Linnemann, J.T.

    1981-01-01

    A measurement of single photon production from p-p collisions at ISR energies is presented. A signal comparable to single π 0 production is found at large p/sub T/. A study of associated particles favors production dominated by the first-order QCD process of gluon-valence quark production q g → q γ

  7. Single-photon sources based on single molecules in solids

    International Nuclear Information System (INIS)

    Moerner, W E

    2004-01-01

    Single molecules in suitable host crystals have been demonstrated to be useful single-photon emitters both at liquid-helium temperatures and at room temperature. The low-temperature source achieved controllable emission of single photons from a single terrylene molecule in p-terphenyl by an adiabatic rapid passage technique. In contrast with almost all other single-molecule systems, terrylene single molecules show extremely high photostability under continuous, high-intensity irradiation. A room-temperature source utilizing this material has been demonstrated, in which fast pumping into vibrational sidebands of the electronically excited state achieved efficient inversion of the emissive level. This source yielded a single-photon emission probability p(1) of 0.86 at a detected count rate near 300 000 photons s -1 , with very small probability of emission of more than one photon. Thus, single molecules in solids can be considered as contenders for applications of single-photon sources such as quantum key distribution

  8. The physics of nanowire superconducting single-photon detectors

    NARCIS (Netherlands)

    Renema, Jelmer Jan

    2015-01-01

    We investigate the detection mechanism in superconducting single photon detectors via quantum detector tomography. We find that the detection event is caused by diffusion of quasiparticles from the absorption spot, combined with entrance of a vortex. Moreover, we investigate the behaviour of

  9. High-speed single-photon signaling for daytime QKD

    Science.gov (United States)

    Bienfang, Joshua; Restelli, Alessandro; Clark, Charles

    2011-03-01

    The distribution of quantum-generated cryptographic key at high throughputs can be critically limited by the performance of the systems' single-photon detectors. While noise and afterpulsing are considerations for all single-photon QKD systems, high-transmission rate systems also have critical detector timing-resolution and recovery time requirements. We present experimental results exploiting the high timing resolution and count-rate stability of modified single-photon avalanche diodes (SPADs) in our GHz QKD system operating over a 1.5 km free-space link that demonstrate the ability to apply extremely short temporal gates, enabling daytime free-space QKD with a 4% QBER. We also discuss recent advances in gating techniques for InGaAs SPADs that are suitable for high-speed fiber-based QKD. We present afterpulse-probability measurements that demonstrate the ability to support single-photon count rates above 100 MHz with low afterpulse probability. These results will benefit the design and characterization of free-space and fiber QKD systems. A. Restelli, J.C. Bienfang A. Mink, and C.W. Clark, IEEE J. Sel. Topics in Quant. Electron 16, 1084 (2010).

  10. Long-Distance Single Photon Transmission from a Trapped Ion via Quantum Frequency Conversion

    Science.gov (United States)

    Walker, Thomas; Miyanishi, Koichiro; Ikuta, Rikizo; Takahashi, Hiroki; Vartabi Kashanian, Samir; Tsujimoto, Yoshiaki; Hayasaka, Kazuhiro; Yamamoto, Takashi; Imoto, Nobuyuki; Keller, Matthias

    2018-05-01

    Trapped atomic ions are ideal single photon emitters with long-lived internal states which can be entangled with emitted photons. Coupling the ion to an optical cavity enables the efficient emission of single photons into a single spatial mode and grants control over their temporal shape. These features are key for quantum information processing and quantum communication. However, the photons emitted by these systems are unsuitable for long-distance transmission due to their wavelengths. Here we report the transmission of single photons from a single 40Ca+ ion coupled to an optical cavity over a 10 km optical fiber via frequency conversion from 866 nm to the telecom C band at 1530 nm. We observe nonclassical photon statistics of the direct cavity emission, the converted photons, and the 10 km transmitted photons, as well as the preservation of the photons' temporal shape throughout. This telecommunication-ready system can be a key component for long-distance quantum communication as well as future cloud quantum computation.

  11. A study of pile-up in integrated time-correlated single photon counting systems.

    Science.gov (United States)

    Arlt, Jochen; Tyndall, David; Rae, Bruce R; Li, David D-U; Richardson, Justin A; Henderson, Robert K

    2013-10-01

    Recent demonstration of highly integrated, solid-state, time-correlated single photon counting (TCSPC) systems in CMOS technology is set to provide significant increases in performance over existing bulky, expensive hardware. Arrays of single photon single photon avalanche diode (SPAD) detectors, timing channels, and signal processing can be integrated on a single silicon chip with a degree of parallelism and computational speed that is unattainable by discrete photomultiplier tube and photon counting card solutions. New multi-channel, multi-detector TCSPC sensor architectures with greatly enhanced throughput due to minimal detector transit (dead) time or timing channel dead time are now feasible. In this paper, we study the potential for future integrated, solid-state TCSPC sensors to exceed the photon pile-up limit through analytic formula and simulation. The results are validated using a 10% fill factor SPAD array and an 8-channel, 52 ps resolution time-to-digital conversion architecture with embedded lifetime estimation. It is demonstrated that pile-up insensitive acquisition is attainable at greater than 10 times the pulse repetition rate providing over 60 dB of extended dynamic range to the TCSPC technique. Our results predict future CMOS TCSPC sensors capable of live-cell transient observations in confocal scanning microscopy, improved resolution of near-infrared optical tomography systems, and fluorescence lifetime activated cell sorting.

  12. On-demand semiconductor single-photon source with near-unity indistinguishability.

    Science.gov (United States)

    He, Yu-Ming; He, Yu; Wei, Yu-Jia; Wu, Dian; Atatüre, Mete; Schneider, Christian; Höfling, Sven; Kamp, Martin; Lu, Chao-Yang; Pan, Jian-Wei

    2013-03-01

    Single-photon sources based on semiconductor quantum dots offer distinct advantages for quantum information, including a scalable solid-state platform, ultrabrightness and interconnectivity with matter qubits. A key prerequisite for their use in optical quantum computing and solid-state networks is a high level of efficiency and indistinguishability. Pulsed resonance fluorescence has been anticipated as the optimum condition for the deterministic generation of high-quality photons with vanishing effects of dephasing. Here, we generate pulsed single photons on demand from a single, microcavity-embedded quantum dot under s-shell excitation with 3 ps laser pulses. The π pulse-excited resonance-fluorescence photons have less than 0.3% background contribution and a vanishing two-photon emission probability. Non-postselective Hong-Ou-Mandel interference between two successively emitted photons is observed with a visibility of 0.97(2), comparable to trapped atoms and ions. Two single photons are further used to implement a high-fidelity quantum controlled-NOT gate.

  13. Multiple-Event, Single-Photon Counting Imaging Sensor

    Science.gov (United States)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  14. Macintosh/LabVIEW based control and data acquisition system for a single photon counting fluorometer

    Science.gov (United States)

    Stryjewski, Wieslaw J.

    1991-08-01

    A flexible software system has been developed for controlling fluorescence decay measurements using the virtual instrument approach offered by LabVIEW. The time-correlated single photon counting instrument operates under computer control in both manual and automatic mode. Implementation time was short and the equipment is now easier to use, reducing the training time required for new investigators. It is not difficult to customize the front panel or adapt the program to a different instrument. We found LabVIEW much more convenient to use for this application than traditional, textual computer languages.

  15. Single-photon tomographic determination of regional cerebral blood flow in epilepsy

    International Nuclear Information System (INIS)

    Bonte, F.J.; Devous, M.D. Sr.; Stokely, E.M.; Homan, R.W.

    1983-01-01

    Using a single-photon emission computed tomographic scanner (SPECT) the authors determined regional cerebral blood flow (rCBF) with inhaled xenon-133, a noninvasive procedure. Studies were performed in 40 normal individuals, and these were compared with rCBF determinations in 51 patients with seizure disorders. Although positive results were obtained in 15 of 16 patients with mass lesions, the group of principal interest comprised 25 patients suffering from ''temporal lobe'' epilepsy. Only one of these had a positive x-ray computed tomogram, but 16 had positive findings on rCBF study. These findings included increased local blood flow in the ictal state and reduced flow interictally

  16. A single photon emission computed tomograph based on a limited dumber of detectors for fluid flow visualization; Tomographie d'emission gamma a partir d'un nombre limite de detecteurs appliquee a la visualisation d'ecoulements

    Energy Technology Data Exchange (ETDEWEB)

    Legoupil, S

    1999-07-01

    We present in this work a method for fluid flow visualization in a system using radioactive tracers. The method is based on single photon emission computed tomography techniques, applied to a limited number of discrete detectors. We propose in this work a method for the estimation of the transport matrix of photons, associated to the acquisition system.This method is based on the modelization of profiles acquired for a set of point sources located in the imaged volume. Monte Carlo simulations allow to separate scattered photons from those directly collected by the system. The influence of the energy tracer is exposed. The reconstruction method is based on the maximum likelihood - expectation maximization algorithm. An experimental device, based on 36 detectors was realised for the visualization of water circulation in a vessel. A video monitoring allows to visualize the dye water tracer. Dye and radioactive tracers are injected simultaneously in a water flow circulating in the vessel. Reconstructed and video images are compared. Quantitative and qualitative analysis show that fluid flow visualization is feasible with a limited number of detectors. This method can be applied for system involving circulations of fluids. (author)

  17. Does preoperative measurement of cerebral blood flow with acetazolamide challenge in addition to preoperative measurement of cerebral blood flow at the resting state increase the predictive accuracy of development of cerebral hyperperfusion after carotid endarterectomy? Results from 500 cases with brain perfusion single-photon emission computed tomography study.

    Science.gov (United States)

    Oshida, Sotaro; Ogasawara, Kuniaki; Saura, Hiroaki; Yoshida, Koji; Fujiwara, Shunro; Kojima, Daigo; Kobayashi, Masakazu; Yoshida, Kenji; Kubo, Yoshitaka; Ogawa, Akira

    2015-01-01

    The purpose of the present study was to determine whether preoperative measurement of cerebral blood flow (CBF) with acetazolamide in addition to preoperative measurement of CBF at the resting state increases the predictive accuracy of development of cerebral hyperperfusion after carotid endarterectomy (CEA). CBF at the resting state and cerebrovascular reactivity (CVR) to acetazolamide were quantitatively assessed using N-isopropyl-p-[(123)I]-iodoamphetamine (IMP)-autoradiography method with single-photon emission computed tomography (SPECT) before CEA in 500 patients with ipsilateral internal carotid artery stenosis (≥ 70%). CBF measurement using (123)I-IMP SPECT was also performed immediately and 3 days after CEA. A region of interest (ROI) was automatically placed in the middle cerebral artery territory in the affected cerebral hemisphere using a three-dimensional stereotactic ROI template. Preoperative decreases in CBF at the resting state [95% confidence intervals (CIs), 0.855 to 0.967; P = 0.0023] and preoperative decreases in CVR to acetazolamide (95% CIs, 0.844 to 0.912; P state (difference between areas, 0.173; P state (P state increases the predictive accuracy of the development of post-CEA hyperperfusion.

  18. Interfering Heralded Single Photons from Two Separate Silicon Nanowires Pumped at Different Wavelengths

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2016-08-01

    Full Text Available Practical quantum photonic applications require on-demand single photon sources. As one possible solution, active temporal and wavelength multiplexing has been proposed to build an on-demand single photon source. In this scheme, heralded single photons are generated from different pump wavelengths in many temporal modes. However, the indistinguishability of these heralded single photons has not yet been experimentally confirmed. In this work, we achieve 88% ± 8% Hong–Ou–Mandel quantum interference visibility from heralded single photons generated from two separate silicon nanowires pumped at different wavelengths. This demonstrates that active temporal and wavelength multiplexing could generate indistinguishable heralded single photons.

  19. Protecting single-photon entanglement with practical entanglement source

    Science.gov (United States)

    Zhou, Lan; Ou-Yang, Yang; Wang, Lei; Sheng, Yu-Bo

    2017-06-01

    Single-photon entanglement (SPE) is important for quantum communication and quantum information processing. However, SPE is sensitive to photon loss. In this paper, we discuss a linear optical amplification protocol for protecting SPE. Different from the previous protocols, we exploit the practical spontaneous parametric down-conversion (SPDC) source to realize the amplification, for the ideal entanglement source is unavailable in current quantum technology. Moreover, we prove that the amplification using the entanglement generated from SPDC source as auxiliary is better than the amplification assisted with single photons. The reason is that the vacuum state from SPDC source will not affect the amplification, so that it can be eliminated automatically. This protocol may be useful in future long-distance quantum communications.

  20. Multi-group dynamic quantum secret sharing with single photons

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongwei [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Ma, Haiqiang, E-mail: hqma@bupt.edu.cn [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Wei, Kejin [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Yang, Xiuqing [School of Science, Beijing Jiaotong University, Beijing 100044 (China); Qu, Wenxiu; Dou, Tianqi; Chen, Yitian; Li, Ruixue; Zhu, Wu [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2016-07-15

    In this letter, we propose a novel scheme for the realization of single-photon dynamic quantum secret sharing between a boss and three dynamic agent groups. In our system, the boss can not only choose one of these three groups to share the secret with, but also can share two sets of independent keys with two groups without redistribution. Furthermore, the security of communication is enhanced by using a control mode. Compared with previous schemes, our scheme is more flexible and will contribute to a practical application. - Highlights: • A multi-group dynamic quantum secret sharing with single photons scheme is proposed. • Any one of the groups can be chosen to share secret through controlling the polarization of photons. • Two sets of keys can be shared simultaneously without redistribution.

  1. Localization of Narrowband Single Photon Emitters in Nanodiamonds.

    Science.gov (United States)

    Bray, Kerem; Sandstrom, Russell; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-03-23

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bioimaging. However, current understanding of the origin of these emitters is extremely limited. In this work, we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond and are directly relevant to fabrication of novel quantum optics devices and sensors.

  2. Zn doped GaN for single-photon emission

    Energy Technology Data Exchange (ETDEWEB)

    Behrends, Arne; Ledig, Johannes; Al-Suleiman, Mohamed Aid Mansur; Bakin, Andrey; Waag, Andreas [Institute of Semiconductor Technology, University of Technology Braunschweig, Hans-Sommer-Str. 66, 38106 Braunschweig (Germany); Peters, Silke; Racu, Ana Maria; Schmunk, Waldemar; Hofer, Helmut; Kueck, Stefan [Physikalisch Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany)

    2012-03-15

    In this work we report on the optical investigation of Zn doped GaN films fabricated by metal organic chemical vapor deposition. The samples show bright emission in the blue spectral range around 2.9 eV when Si codoping is provided. This emission is suggested to be used for single-photon emission, thus the density of the Zn-Si pairs was drastically reduced leading to a decrease of the blue luminescence. For electrically excited single-photon sources these Zn-Si pairs have to be incorporated into LEDs, therefore we fabricated GaN-based nano-LEDs which show electroluminescence at 430 nm (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Authenticated Quantum Key Distribution with Collective Detection using Single Photons

    Science.gov (United States)

    Huang, Wei; Xu, Bing-Jie; Duan, Ji-Tong; Liu, Bin; Su, Qi; He, Yuan-Hang; Jia, Heng-Yue

    2016-10-01

    We present two authenticated quantum key distribution (AQKD) protocols by utilizing the idea of collective (eavesdropping) detection. One is a two-party AQKD protocol, the other is a multiparty AQKD protocol with star network topology. In these protocols, the classical channels need not be assumed to be authenticated and the single photons are used as the quantum information carriers. To achieve mutual identity authentication and establish a random key in each of the proposed protocols, only one participant should be capable of preparing and measuring single photons, and the main quantum ability that the rest of the participants should have is just performing certain unitary operations. Security analysis shows that these protocols are free from various kinds of attacks, especially the impersonation attack and the man-in-the-middle (MITM) attack.

  4. Very bright, near-infrared single photon emitters in diamond

    Directory of Open Access Journals (Sweden)

    D. W. M. Lau

    2013-09-01

    Full Text Available We demonstrate activation of bright diamond single photon emitters in the near infrared range by thermal annealing alone, i.e., without ion implantation. The activation is crucially dependent on the annealing ambient. The activation of the single photon emitters is only observed when the sample is annealed in forming gas (4% H2 in Ar above temperatures of 1000 °C. By contrast, no emitters are activated by annealing in vacuum, oxygen, argon or deuterium. The emitters activated by annealing in forming gas exhibit very bright emission in the 730-760 nm wavelength range and have linewidths of ∼1.5-2.5 nm at room temperature.

  5. Advanced time-correlated single photon counting applications

    CERN Document Server

    Becker, Wolfgang

    2015-01-01

    This book is an attempt to bridge the gap between the instrumental principles of multi-dimensional time-correlated single photon counting (TCSPC) and typical applications of the technique. Written by an originator of the technique and by sucessful users, it covers the basic principles of the technique, its interaction with optical imaging methods and its application to a wide range of experimental tasks in life sciences and clinical research. The book is recommended for all users of time-resolved detection techniques in biology, bio-chemistry, spectroscopy of live systems, live cell microscopy, clinical imaging, spectroscopy of single molecules, and other applications that require the detection of low-level light signals at single-photon sensitivity and picosecond time resolution.

  6. Directional emission of single photons from small atomic samples

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; V. Poulsen, Uffe; Mølmer, Klaus

    2013-01-01

    We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state i...... is coupled by a classical laser field to an optically excited state which rapidly decays to the ground atomic state. Our model accounts for the different field polarization components via re-absorption and emission of light by the Zeeman manifold of optically excited states.......We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state...

  7. On the scalar electron mass limit from single photon experiments

    International Nuclear Information System (INIS)

    Grivaz, J.F.

    1987-03-01

    We discuss how the 90% C.L. lower limit on the mass of the scalar electron, as extracted from the single photon experiments, is affected by the way the background from radiative neutrino pair production is handled. We argue that some of the results presented at the Berkeley conference are overoptimistic, and that the mass lower limit is 65 GeV rather than the advertized value of 84 GeV, for the case of degenerate scalar electrons with massless photinos

  8. Secure authentication of classical messages with single photons

    International Nuclear Information System (INIS)

    Tian-Yin, Wang; Qiao-Yan, Wen; Fu-Chen, Zhu

    2009-01-01

    This paper proposes a scheme for secure authentication of classical messages with single photons and a hashed function. The security analysis of this scheme is also given, which shows that anyone cannot forge valid message authentication codes (MACs). In addition, the lengths of the authentication key and the MACs are invariable and shorter, in comparison with those presented authentication schemes. Moreover, quantum data storage and entanglement are not required in this scheme. Therefore, this scheme is more efficient and economical. (general)

  9. Processing of transmission data from an uncollimated single photon source

    International Nuclear Information System (INIS)

    Dikaios, N.; Dinelle, K.; Spinks, T.; Nikita, K.; Thielemans, K.

    2006-01-01

    The EXACT 3D PET scanner uses a Cs-137 single photon rotating point source for the transmission scan. As the source is un-collimated, the transmission data are contaminated by scatter. It has been suggested that segmentation of the reconstructed image can restore the quantitative information in the image. We study here if the results can be further improved by the application of a scale factor for every transaxial plane

  10. Single photon detection with self-quenching multiplication

    Science.gov (United States)

    Zheng, Xinyu (Inventor); Cunningham, Thomas J. (Inventor); Pain, Bedabrata (Inventor)

    2011-01-01

    A photoelectronic device and an avalanche self-quenching process for a photoelectronic device are described. The photoelectronic device comprises a nanoscale semiconductor multiplication region and a nanoscale doped semiconductor quenching structure including a depletion region and an undepletion region. The photoelectronic device can act as a single photon detector or a single carrier multiplier. The avalanche self-quenching process allows electrical field reduction in the multiplication region by movement of the multiplication carriers, thus quenching the avalanche.

  11. Semi-quantum Dialogue Based on Single Photons

    Science.gov (United States)

    Ye, Tian-Yu; Ye, Chong-Qiang

    2018-02-01

    In this paper, we propose two semi-quantum dialogue (SQD) protocols by using single photons as the quantum carriers, where one requires the classical party to possess the measurement capability and the other does not have this requirement. The security toward active attacks from an outside Eve in the first SQD protocol is guaranteed by the complete robustness of present semi-quantum key distribution (SQKD) protocols, the classical one-time pad encryption, the classical party's randomization operation and the decoy photon technology. The information leakage problem of the first SQD protocol is overcome by the classical party' classical basis measurements on the single photons carrying messages which makes him share their initial states with the quantum party. The security toward active attacks from Eve in the second SQD protocol is guaranteed by the classical party's randomization operation, the complete robustness of present SQKD protocol and the classical one-time pad encryption. The information leakage problem of the second SQD protocol is overcome by the quantum party' classical basis measurements on each two adjacent single photons carrying messages which makes her share their initial states with the classical party. Compared with the traditional information leakage resistant QD protocols, the advantage of the proposed SQD protocols lies in that they only require one party to have quantum capabilities. Compared with the existing SQD protocol, the advantage of the proposed SQD protocols lies in that they only employ single photons rather than two-photon entangled states as the quantum carriers. The proposed SQD protocols can be implemented with present quantum technologies.

  12. Single-photon ultrashort-lived radionuclides: symposium proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Paras, P.; Thiessen, J.W. (eds.)

    1985-01-01

    The purpose was to define the current role and state-of-the-art regarding the development, clinical applications, and usefulness of generator-produced single-photon ultrashort-lived radionuclides (SPUSLR's) and to predict their future impact on medicine. Special emphasis was placed on the generator production of iridium-191, gold-195, and krypton-81. This report contains expanded summaries of the included papers. (ACR)

  13. Single-photon emission computed tomography (SPECT) in oediatric migraine

    International Nuclear Information System (INIS)

    Battistella, P.A.; Pitassi, I.; Ruffilli, R.; Boniver, C.; Suppiej, A.; Casara, G.

    1989-01-01

    Cerebral blood flow in pediatric patients suffering from different types of migraine is analyzed by SPECT with 99m Tc HM-PAO, during the pain free intervals. The results indicate that such studies may give further information toward the understanding of common and classic forms of migraine and the difference in the CBF patterns of these forms support the hypothesis of a possible different pathogenesis. (H.W.). 13 refs.; 1 tab

  14. Perfusion imaging with single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Holman, B.L.; Hill, T.C.

    1987-01-01

    SPECT with perfusion tracers is useful in a number of circumstances: (1) In acute cerebral infarction while the CT scan may be normal for several days after onset of symptoms, the uptake of SPECT perfusion tracers will be altered immediately after the onset of the stroke. Even when the CT scan has become abnormal, the physiologic abnormality may exceed the anatomic abnormality. One may, therefore be able to measure the extent of the reversibly ischemic tissue early enough to justify more agressive therapeutic interventions. (2) For endarterectomy and other surgical and medical therapies serial measurements of regional cerebral perfusion with SPECT may provide a readily available tool to assess their efficacy. (3) SPECT perfusion imaging may become the method of choice for the diagnosis and evaluation of Alzheimer's disease. (4) In patients with epilepsy, the extent and location of the abnormally perfused focus may be important to medical and surgical management. Follow-up examination may be useful in documenting the effectiveness of therapy

  15. Patient motion correction for single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Geckle, W.J.; Becker, L.C.; Links, J.M.; Frank, T.

    1986-01-01

    An investigation has been conducted to develop and validate techniques for the correction of projection images in SPECT studies of the myocardium subject to misalignment due to voluntary patient motion. The problem is frequently encountered due to the uncomfortable position the patient must assume during the 30 minutes required to obtain a 180 degree set of projection images. The reconstruction of misaligned projections can lead to troublesome artifacts in reconstructed images and degrade the diagnostic potential of the procedure. Significant improvement in the quality of heart reconstructions has been realized with the implementation of an algorithm to provide detection of and correction for patient motion. Normal, involuntary motion is not corrected for, however, since such movement is below the spatial resolution of the thallium imaging system under study. The algorithm is based on a comparison of the positions of an object in a set of projection images to the known, sinusoidal trajectory of an off-axis fixed point in space. Projection alignment, therefore, is achieved by shifting the position of a point or set of points in a projection image to the sinusoid of a fixed position in space

  16. Single photon emission computed tomography (SPECT) in neurocysticercosis

    International Nuclear Information System (INIS)

    Braga, Francisco Jose H. N; Santos, Antonio C; Takanayagui, Oswaldo M; Agapejev, Svetlana; Maes, A

    2002-01-01

    Neurocysticercosis (NC) is a parasitic infectious disease caused by Taenia solium eggs that set in the brain. Its incidence is increasing both in the developing and the developed world, as a result of low economical and hygiene levels and immigration, respectively. Clinical manifestation of disease varies from no symptoms to epilepsy, increased intra-cranial pressure, arachnoiditis and dementia. In order to evaluate function (perfusion) of affected brains, we studied 40 patients (21 females and 19 males, 19-71 yo) by means of SPECT (ECD, ethyl cysteinate dimer, labelled with 99mTc) and with and without contrast CT. SPECT studies were all abnormal. No difference was noted between active and inactive disease. Two SPECT patterns were noted: a) several areas of focally reduced uptake, resulting from coalescent and big lesions and large destruction of brain tissue (small, isolated and symmetric cysts seen in CT were missed by SPECT); b) diffuse atrophy with reduction of the tracer uptake, associated with ventricle dilatation, corresponding to the cases where ventricular NC was important. Interestingly, we noted diffuse hypoperfusion, with the scintigraphic pattern of atrophy in 5 cases of massive parenchymal infection; in such cases, CT signs of atrophy were clearly less prominent. The first scintigraphic aspect can be explained by the destruction of large areas of brain, which produces focal absence of perfusion; generalised vasculitis and the destruction of large portions of brain tissue could explain the difference noted between the SPECT and the CT aspects in the 5 cases of massive parenchimal infection, and this may be interesting for prognosis. Dilatation of ventricles and Sylvian fissures were interestingly prominent in SPECT. SPECT may be of great value to evaluate brain perfusion in NC (Au)

  17. Clinical impact of (11)C-Pittsburgh compound-B positron emission tomography carried out in addition to magnetic resonance imaging and single-photon emission computed tomography on the diagnosis of Alzheimer's disease in patients with dementia and mild cognitive impairment.

    Science.gov (United States)

    Omachi, Yoshie; Ito, Kimiteru; Arima, Kunimasa; Matsuda, Hiroshi; Nakata, Yasuhiro; Sakata, Masuhiro; Sato, Noriko; Nakagome, Kazuyuki; Motohashi, Nobutaka

    2015-12-01

    The purpose of this study was to evaluate the clinical impact of addition of [(11)C]Pittsburgh compound-B positron emission tomography ((11)C-PiB PET) on routine clinical diagnosis of Alzheimer's disease (AD) dementia and mild cognitive impairment (MCI), and to assess diagnostic agreement between clinical criteria and research criteria of the National Institute on Aging-Alzheimer's Association. The diagnosis in 85 patients was made according to clinical criteria. Imaging examinations, including both magnetic resonance imaging and single-photon emission computed tomography/computed tomography to identify neuronal injury (NI), and (11)C-PiB PET to identify amyloid were performed, and all subjects were re-categorized according to the research criteria. Among 40 patients with probable AD dementia (ProAD), 37 were NI-positive, 29 were (11)C-PiB-positive, and 27 who were both NI- and (11C-PiB-positive were categorized as having 'ProAD dementia with a high level of evidence of the AD pathophysiological process'. Among 20 patients with possible AD dementia (PosAD), 17 were NI-positive, and six who were both NI- and (11)C-PiB-positive were categorized as having 'PosAD with evidence of the AD pathophysiological process'. Among 25 patients with MCI, 18 were NI-positive, 13 were (11)C-PiB-positive, and 10 who were both NI- and (11)C-PiB-positive were categorized as having 'MCI due to AD-high likelihood'. Diagnostic concordance between clinical criteria and research criteria may not be high in this study. (11)C-PiB PET may be of value in making the diagnosis of dementia and MCI in cases with high diagnostic uncertainty. © 2015 The Authors. Psychiatry and Clinical Neurosciences © 2015 Japanese Society of Psychiatry and Neurology.

  18. Optimal entangling operations between deterministic blocks of qubits encoded into single photons

    Science.gov (United States)

    Smith, Jake A.; Kaplan, Lev

    2018-01-01

    Here, we numerically simulate probabilistic elementary entangling operations between rail-encoded photons for the purpose of scalable universal quantum computation or communication. We propose grouping logical qubits into single-photon blocks wherein single-qubit rotations and the controlled-not (cnot) gate are fully deterministic and simple to implement. Interblock communication is then allowed through said probabilistic entangling operations. We find a promising trend in the increasing probability of successful interblock communication as we increase the number of optical modes operated on by our elementary entangling operations.

  19. Coherent single-photon absorption by single emitters coupled to 1D nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2012-01-01

    We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption.......We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption....

  20. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association.

    Science.gov (United States)

    Brindis, Ralph G; Douglas, Pamela S; Hendel, Robert C; Peterson, Eric D; Wolk, Michael J; Allen, Joseph M; Patel, Manesh R; Raskin, Ira E; Hendel, Robert C; Bateman, Timothy M; Cerqueira, Manuel D; Gibbons, Raymond J; Gillam, Linda D; Gillespie, John A; Hendel, Robert C; Iskandrian, Ami E; Jerome, Scott D; Krumholz, Harlan M; Messer, Joseph V; Spertus, John A; Stowers, Stephen A

    2005-10-18

    Under the auspices of the American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC), an appropriateness review was conducted for radionuclide cardiovascular imaging (RNI), specifically gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). The review assessed the risks and benefits of the imaging test for several indications or clinical scenarios and scored them based on a scale of 1 to 9, where the upper range (7 to 9) implies that the test is generally acceptable and is a reasonable approach, and the lower range (1 to 3) implies that the test is generally not acceptable and is not a reasonable approach. The mid range (4 to 6) implies that the test may be generally acceptable and may be a reasonable approach for the indication. The indications for this review were primarily drawn from existing clinical practice guidelines and modified based on discussion by the ACCF Appropriateness Criteria Working Group and the Technical Panel members who rated the indications. The method for this review was based on the RAND/UCLA approach for evaluating appropriateness, which blends scientific evidence and practice experience. A modified Delphi technique was used to obtain first- and second-round ratings of 52 clinical indications. The ratings were done by a Technical Panel with diverse membership, including nuclear cardiologists, referring physicians (including an echocardiographer), health services researchers, and a payer (chief medical officer). These results are expected to have a significant impact on physician decision making and performance, reimbursement policy, and future research directions. Periodic assessment and updating of criteria will be undertaken as needed.

  1. Single-photon two-qubit entangled states: Preparation and measurement

    International Nuclear Information System (INIS)

    Kim, Yoon-Ho

    2003-01-01

    We implement experimentally a deterministic method to prepare and measure the so-called single-photon two-qubit entangled states or single-photon Bell states, in which the polarization and the spatial modes of a single photon each represent a quantum bit. All four single-photon Bell states can be easily prepared and measured deterministically using linear optical elements alone. We also discuss how this method can be used for the recently proposed single-photon two-qubit quantum cryptography scheme

  2. Optimised quantum hacking of superconducting nanowire single-photon detectors.

    Science.gov (United States)

    Tanner, Michael G; Makarov, Vadim; Hadfield, Robert H

    2014-03-24

    We explore bright-light control of superconducting nanowire single-photon detectors (SNSPDs) in the shunted configuration (a practical measure to avoid latching). In an experiment, we simulate an illumination pattern the SNSPD would receive in a typical quantum key distribution system under hacking attack. We show that it effectively blinds and controls the SNSPD. The transient blinding illumination lasts for a fraction of a microsecond and produces several deterministic fake clicks during this time. This attack does not lead to elevated timing jitter in the spoofed output pulse, and hence does not introduce significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  3. High bit rate germanium single photon detectors for 1310nm

    Science.gov (United States)

    Seamons, J. A.; Carroll, M. S.

    2008-04-01

    There is increasing interest in development of high speed, low noise and readily fieldable near infrared (NIR) single photon detectors. InGaAs/InP Avalanche photodiodes (APD) operated in Geiger mode (GM) are a leading choice for NIR due to their preeminence in optical networking. After-pulsing is, however, a primary challenge to operating InGaAs/InP single photon detectors at high frequencies1. After-pulsing is the effect of charge being released from traps that trigger false ("dark") counts. To overcome this problem, hold-off times between detection windows are used to allow the traps to discharge to suppress after-pulsing. The hold-off time represents, however, an upper limit on detection frequency that shows degradation beginning at frequencies of ~100 kHz in InGaAs/InP. Alternatively, germanium (Ge) single photon avalanche photodiodes (SPAD) have been reported to have more than an order of magnitude smaller charge trap densities than InGaAs/InP SPADs2, which allowed them to be successfully operated with passive quenching2 (i.e., no gated hold off times necessary), which is not possible with InGaAs/InP SPADs, indicating a much weaker dark count dependence on hold-off time consistent with fewer charge traps. Despite these encouraging results suggesting a possible higher operating frequency limit for Ge SPADs, little has been reported on Ge SPAD performance at high frequencies presumably because previous work with Ge SPADs has been discouraged by a strong demand to work at 1550 nm. NIR SPADs require cooling, which in the case of Ge SPADs dramatically reduces the quantum efficiency of the Ge at 1550 nm. Recently, however, advantages to working at 1310 nm have been suggested which combined with a need to increase quantum bit rates for quantum key distribution (QKD) motivates examination of Ge detectors performance at very high detection rates where InGaAs/InP does not perform as well. Presented in this paper are measurements of a commercially available Ge APD

  4. Optimised quantum hacking of superconducting nanowire single-photon detectors

    Science.gov (United States)

    Tanner, Michael G.; Makarov, Vadim; Hadfield, Robert H.

    2014-03-01

    We explore bright-light control of superconducting nanowire single-photon detectors (SNSPDs) in the shunted configuration (a practical measure to avoid latching). In an experiment, we simulate an illumination pattern the SNSPD would receive in a typical quantum key distribution system under hacking attack. We show that it effectively blinds and controls the SNSPD. The transient blinding illumination lasts for a fraction of a microsecond and produces several deterministic fake clicks during this time. This attack does not lead to elevated timing jitter in the spoofed output pulse, and hence does not introduce significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  5. Quantum Secure Direct Communication with Authentication Expansion Using Single Photons

    International Nuclear Information System (INIS)

    Yang Jing; Wang Chuan; Zhang Ru

    2010-01-01

    In this paper we propose two quantum secure direct communication (QSDC) protocols with authentication. The authentication key expansion method is introduced to improve the life of the keys with security. In the first scheme, the third party, called Trent is introduced to authenticate the users that participate in the communication. He sends the polarized photons in blocks to authenticate communication parties Alice and Bob using the authentication keys. In the communication process, polarized single photons are used to serve as the carriers, which transmit the secret messages directly. The second QSDC process with authentication between two parties is also discussed.

  6. Quasi free mechanism in single photon double ionization of helium

    Energy Technology Data Exchange (ETDEWEB)

    Schoeffler, Markus; Stuck, Christian [Frankfurt Univ., Frankfurt am Main (Germany). Inst. fuer Kernphysik; Lawrence Berkeley National Lab, Berkeley, CA (United States); Jahnke, Till; Waitz, Markus; Trinter, Florian; Lenz, Ute; Schmidt-Boecking, Horst; Doerner, Reinhard [Frankfurt Univ., Frankfurt am Main (Germany). Inst. fuer Kernphysik; Jones, Mathew; Landers, Allen [Auburn University, Auburn, AL (United States); Belkacem, Ali; Weber, Thorsten [Lawrence Berkeley National Lab, Berkeley, CA (United States); Cocke, Lew [Kansas State University, Manhattan, KS (United States)

    2012-07-01

    Double ionization of Helium by a single photon is widely believed to proceed through two mechanisms: knock-off (TS1) or shake-off, with the last one dominating at high photon energies. A new mechanism, termed ''Quasi Free Mechanism'' (QFM) was predicted 35 years ago by Amusia and coworkers, but escaped experimental observation till today. Here we provide the first proof of this mechanism using 800 eV photons from the Advanced Light Source. Fragments (electrons and ions) were measured in coincidence using momentum spectroscopy (COLTRIMS). He{sup (}2+) ions with zero momentum were found - the fingerprint for the QFM.

  7. Deterministic Single-Photon Source for Distributed Quantum Networking

    International Nuclear Information System (INIS)

    Kuhn, Axel; Hennrich, Markus; Rempe, Gerhard

    2002-01-01

    A sequence of single photons is emitted on demand from a single three-level atom strongly coupled to a high-finesse optical cavity. The photons are generated by an adiabatically driven stimulated Raman transition between two atomic ground states, with the vacuum field of the cavity stimulating one branch of the transition, and laser pulses deterministically driving the other branch. This process is unitary and therefore intrinsically reversible, which is essential for quantum communication and networking, and the photons should be appropriate for all-optical quantum information processing

  8. Heralded noiseless amplification for single-photon entangled state with polarization feature

    Science.gov (United States)

    Wang, Dan-Dan; Jin, Yu-Yu; Qin, Sheng-Xian; Zu, Hao; Zhou, Lan; Zhong, Wei; Sheng, Yu-Bo

    2018-03-01

    Heralded noiseless amplification is a promising method to overcome the transmission photon loss in practical noisy quantum channel and can effectively lengthen the quantum communication distance. Single-photon entanglement is an important resource in current quantum communications. Here, we construct two single-photon-assisted heralded noiseless amplification protocols for the single-photon two-mode entangled state and single-photon three-mode W state, respectively, where the single-photon qubit has an arbitrary unknown polarization feature. After the amplification, the fidelity of the single-photon entangled state can be increased, while the polarization feature of the single-photon qubit can be well remained. Both the two protocols only require the linear optical elements, so that they can be realized under current experimental condition. Our protocols may be useful in current and future quantum information processing.

  9. Ultrabright and efficient single-photon generation based on nitrogen-vacancy centres in nanodiamonds on a solid immersion lens

    International Nuclear Information System (INIS)

    Schroeder, Tim; Gaedeke, Friedemann; Banholzer, Moritz Julian; Benson, Oliver

    2011-01-01

    Single photons are fundamental elements for quantum information technologies such as quantum cryptography, quantum information storage and optical quantum computing. Colour centres in diamond have proven to be stable single-photon sources and thus essential components for reliable and integrated quantum information technology. A key requirement for such applications is a large photon flux and a high efficiency. Paying tribute to various attempts to maximize the single-photon flux, we show that collection efficiencies of photons from colour centres can be increased with a rather simple experimental setup. To do so, we spin-coated nanodiamonds containing single nitrogen-vacancy (N-V) colour centres on the flat surface of a ZrO 2 solid immersion lens. We found stable single-photon count rates of up to 853 kcts s -1 at saturation under continuous wave excitation while having access to more than 100 defect centres with count rates from 400 to 500 kcts s -1 . For a blinking defect centre, we found count rates up to 2.4 Mcts s -1 for time intervals of several tens of seconds. It seems to be a general feature that very high rates are accompanied by blinking behaviour. The overall collection efficiency of our setup of up to 4.2% is the highest yet reported for N-V defect centres in diamond. Under pulsed excitation of a stable emitter of 10 MHz, 2.2% of all pulses caused a click on the detector adding to 221 kcts s -1 thus, opening the way towards diamond-based on-demand single-photon sources for quantum applications.

  10. Ultrabright and efficient single-photon generation based on nitrogen-vacancy centres in nanodiamonds on a solid immersion lens

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Tim; Gaedeke, Friedemann; Banholzer, Moritz Julian; Benson, Oliver, E-mail: tim.schroeder@physik.hu-berlin.de [Humboldt-Universitaet zu Berlin, Institut fuer Physik, AG Nano Optics Newtonstrasse 15, 12489 Berlin (Germany)

    2011-05-15

    Single photons are fundamental elements for quantum information technologies such as quantum cryptography, quantum information storage and optical quantum computing. Colour centres in diamond have proven to be stable single-photon sources and thus essential components for reliable and integrated quantum information technology. A key requirement for such applications is a large photon flux and a high efficiency. Paying tribute to various attempts to maximize the single-photon flux, we show that collection efficiencies of photons from colour centres can be increased with a rather simple experimental setup. To do so, we spin-coated nanodiamonds containing single nitrogen-vacancy (N-V) colour centres on the flat surface of a ZrO{sub 2} solid immersion lens. We found stable single-photon count rates of up to 853 kcts s{sup -1} at saturation under continuous wave excitation while having access to more than 100 defect centres with count rates from 400 to 500 kcts s{sup -1}. For a blinking defect centre, we found count rates up to 2.4 Mcts s{sup -1} for time intervals of several tens of seconds. It seems to be a general feature that very high rates are accompanied by blinking behaviour. The overall collection efficiency of our setup of up to 4.2% is the highest yet reported for N-V defect centres in diamond. Under pulsed excitation of a stable emitter of 10 MHz, 2.2% of all pulses caused a click on the detector adding to 221 kcts s{sup -1} thus, opening the way towards diamond-based on-demand single-photon sources for quantum applications.

  11. Molecular single photon double K-shell ionization

    International Nuclear Information System (INIS)

    Penent, F.; Nakano, M.; Tashiro, M.; Grozdanov, T.P.; Žitnik, M.; Carniato, S.; Selles, P.; Andric, L.; Lablanquie, P.; Palaudoux, J.; Shigemasa, E.; Iwayama, H.; Hikosaka, Y.; Soejima, K.; Suzuki, I.H.; Kouchi, N.; Ito, K.

    2014-01-01

    We have studied single photon double K-shell ionization of small molecules (N 2 , CO, C 2 H 2n (n = 1–3), …) and the Auger decay of the resulting double core hole (DCH) molecular ions thanks to multi-electron coincidence spectroscopy using a magnetic bottle time-of-flight spectrometer. The relative cross-sections for single-site (K −2 ) and two-site (K −1 K −1 ) double K-shell ionization with respect to single K-shell (K −1 ) ionization have been measured that gives important information on the mechanisms of single photon double ionization. The spectroscopy of two-site (K −1 K −1 ) DCH states in the C 2 H 2n (n = 1–3) series shows important chemical shifts due to a strong dependence on the C-C bond length. In addition, the complete cascade Auger decay following single site (K −2 ) ionization has been obtained

  12. Mitigating radiation damage of single photon detectors for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Anisimova, Elena; Higgins, Brendon L.; Bourgoin, Jean-Philippe [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Cranmer, Miles [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Choi, Eric [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Magellan Aerospace, Ottawa, ON (Canada); Hudson, Danya; Piche, Louis P.; Scott, Alan [Honeywell Aerospace (formerly COM DEV Ltd.), Ottawa, ON (Canada); Makarov, Vadim [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); University of Waterloo, Department of Electrical and Computer Engineering, Waterloo, ON (Canada); Jennewein, Thomas [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Canadian Institute for Advanced Research, Quantum Information Science Program, Toronto, ON (Canada)

    2017-12-15

    Single-photon detectors in space must retain useful performance characteristics despite being bombarded with sub-atomic particles. Mitigating the effects of this space radiation is vital to enabling new space applications which require high-fidelity single-photon detection. To this end, we conducted proton radiation tests of various models of avalanche photodiodes (APDs) and one model of photomultiplier tube potentially suitable for satellite-based quantum communications. The samples were irradiated with 106 MeV protons at doses approximately equivalent to lifetimes of 0.6, 6, 12 and 24 months in a low-Earth polar orbit. Although most detection properties were preserved, including efficiency, timing jitter and afterpulsing probability, all APD samples demonstrated significant increases in dark count rate (DCR) due to radiation-induced damage, many orders of magnitude higher than the 200 counts per second (cps) required for ground-to-satellite quantum communications. We then successfully demonstrated the mitigation of this DCR degradation through the use of deep cooling, to as low as -86 C. This achieved DCR below the required 200 cps over the 24 months orbit duration. DCR was further reduced by thermal annealing at temperatures of +50 to +100 C. (orig.)

  13. Single photon laser altimeter simulator and statistical signal processing

    Science.gov (United States)

    Vacek, Michael; Prochazka, Ivan

    2013-05-01

    Spaceborne altimeters are common instruments onboard the deep space rendezvous spacecrafts. They provide range and topographic measurements critical in spacecraft navigation. Simultaneously, the receiver part may be utilized for Earth-to-satellite link, one way time transfer, and precise optical radiometry. The main advantage of single photon counting approach is the ability of processing signals with very low signal-to-noise ratio eliminating the need of large telescopes and high power laser source. Extremely small, rugged and compact microchip lasers can be employed. The major limiting factor, on the other hand, is the acquisition time needed to gather sufficient volume of data in repetitive measurements in order to process and evaluate the data appropriately. Statistical signal processing is adopted to detect signals with average strength much lower than one photon per measurement. A comprehensive simulator design and range signal processing algorithm are presented to identify a mission specific altimeter configuration. Typical mission scenarios (celestial body surface landing and topographical mapping) are simulated and evaluated. The high interest and promising single photon altimeter applications are low-orbit (˜10 km) and low-radial velocity (several m/s) topographical mapping (asteroids, Phobos and Deimos) and landing altimetry (˜10 km) where range evaluation repetition rates of ˜100 Hz and 0.1 m precision may be achieved. Moon landing and asteroid Itokawa topographical mapping scenar