WorldWideScience

Sample records for cancer single-photon computed

  1. Sentinel Lymph Node Detection by 3D Freehand Single-Photon Emission Computed Tomography in Early Stage Breast Cancer

    Directory of Open Access Journals (Sweden)

    Salih Sinan Gültekin

    2016-06-01

    Full Text Available We herein present our first experience obtained by 3D freehand single-photon emission computed tomography (SPECT (F-SPECT guidance for sentinel lymph node detection (SLND in two patients with early stage breast cancer. F-SPECT guidance was carried out using one-day protocol in one case and by the two-day protocol in the other one. SLND was performed successfully in both patients. Histopathologic evaluation showed that the excised nodes were tumor negative. Thus, patients underwent breast-conserving surgery alone.

  2. Laparoscopic Sentinel Node Biopsy Using Real-time 3-dimensional Single-photon Emission Computed Tomographic Guidance in Endometrial Cancer.

    Science.gov (United States)

    Fernandez-Prada, Sara; Delgado-Sanchez, Elsa; De Santiago, Javier; Zapardiel, Ignacio

    2015-01-01

    In endometrial cancer, the histopathological analysis of the lymphatic nodes is essential to establish a correct prognosis and tailored adjuvant treatment. It is well-known that patients with early-stage endometrial cancer have a low incidence of nodal disease. In this group, systematic lymphadenectomy is not recommended. To improve the detection rate of sentinel nodes in clinical practice, new techniques are emerging like real-time 3-dimensional single-photon emission computed tomographic (SPECT) imaging. We report our experience using this innovative technique for intraoperative detection of sentinel nodes in endometrial cancer. The real-time 3-dimensional SPECT sentinel node biopsy seems to be feasible and accurate in endometrial cancer although further studies are needed to set the precision and predictive values compared with the current differed SPECT techniques and blue dye techniques. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  3. Scintimammography and single-photon emission computed tomography for postoperative image guidance for radiation treatment planning in breast cancer patients.

    Science.gov (United States)

    Piperkova, E; Chavdarova, L; Garanina, Z; Gocheva, L; Parvanova, V; Tzonevska, A; Dimitrova, M

    2011-01-01

    To evaluate post-surgical tumor-metabolic regions outside of the computed tomography (CT)-defined volume for radiation therapy (RT) planning using functional imaging of scintimammography (SMG) ± single photon emission computerized tomography (SPECT) in breast cancer (BC) patients. 62 operated high-risk BC females, mean age 50.45 years, underwent SMG±SPECT before RT planning. Twenty-one and twelve patients with stage I and IIa respectively had lumpectomy (LT) with axillary lymph node dissection (ALND), and modified radical mastectomy (Patay) + ALND was realized in 29 stage IIb-III patients. All SMG images, positive for viable tumor tissue (VTT) or metastatically involved lymph nodes (LNs) were verified cytologically/ histologically. Three early planar and delayed images were acquired after i.v. administration of 550-740 MBq 99mTc- MIBI or 99mTc-TF. Uptake values (UV) > 1.65 revealed VTT. Data in 49 (79%) of 62 patients were characterized as true-negative (TN; UVVTT in scars, 1 newly defined BC in the contralateral breast and 18 regional LN metastases (6 axillary, 6 parasternal, 1 sub- and 5 supraclavicular). All 22 TP VTT lesions were imaged by scintigraphy using different tumor-seeking radiopharmaceuticals: 99mTc-MIBI - 17 (77%) and 99mTc- TF - 5 (23%) of the TP lesions. One false-positive (FP) (inflammation: UV>1.65) and one false-negative (FN) (UVVTT, LN metastases or altered biological activity in the scars after BC surgery and could modify the irradiated volume, optimizing the therapeutic effect and minimizing RT side effects.

  4. Protection of lung function by introducing single photon emission computed tomography lung perfusion image into radiotherapy plan of lung cancer

    Institute of Scientific and Technical Information of China (English)

    YIN Yong; CHEN Jin-hu; LI Bao-sheng; LIU Tong-hai; LU jie; BAI Tong; DONG Xiao-ling; YU Jin-ming

    2009-01-01

    Background The lung functional status could be displayed on lung perfusion images. With the images, the radiotherapy plans of lung cancer could be guided to more optimized. This study aimed to assess quantitatively the impact of incorporating functional lung imaging into 3-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiation therapy (IMRT) planning for non-small cell lung cancer (NSCLC).Methods Ten patients with NSCLC who had undergone radiotherapy were included in this study. Before radiotherapy,each patient underwent CT simulation and lung perfusion imaging with single photon emission computed tomography (SPECT). The SPECT images were registered with simulation planning CT and used to contour functional lung (lung-F) and non-functional lung (lung-NF). Two 3DCRT plans and two IMRT plans were designed and compared in each patient:two anatomic plans using simulation CT alone and two functional plans using SPECT-CT in addition to the simulation CT.Dosimetric parameters of the four types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Total radiation dose was set at 66 Gy (2 Gy×33 fractions).Results In incorporating perfusion information in 3DCRT and IMRT planning, the reductions on average in the mean doses to the functional lung in the functional plan were 168 cGy and 89 cGy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with >5 Gy, >10 Gy, >20 Gy, >30 Gy and >40 Gy for functional lung in the functional plans were 6.50%, 10.21%, 14.02%, 22.30% and 23.46% in 3DCRT planning,respectively, and 3.05%, 15.52%, 14.16%, 4.87%, and 3.33% in IMRT planning, respectively. No greater degree of sparing of the functional lung was achieved in functional IMRT than in 3DCRT.Conclusion Function-guided 3DCRT and IMRT plannings both appear to be effective in preserving functional lung in NSCLC patients.

  5. Immunotargeting of Integrin α6β4 for Single-Photon Emission Computed Tomography and Near-Infrared Fluorescence Imaging in a Pancreatic Cancer Model

    Directory of Open Access Journals (Sweden)

    Winn Aung MBBS, PhD

    2016-01-01

    Full Text Available To explore suitable imaging probes for early and specific detection of pancreatic cancer, we demonstrated that α6β4 integrin is a good target and employed single-photon emission computed tomography (SPECT or near-infrared (NIR imaging for immunotargeting. Expression levels of α6β4 were examined by Western blotting and flow cytometry in certain human pancreatic cancer cell lines. The human cell line BxPC-3 was used for α6β4-positive and a mouse cell line, A4, was used for negative counterpart. We labeled antibody against α6β4 with Indium-111 (111In or indocyanine green (ICG. After injection of 111In-labeled probe to tumor-bearing mice, biodistribution, SPECT, autoradiography (ARG, and immunohistochemical (IHC studies were conducted. After administration of ICG-labeled probe, in vivo and ex vivo NIR imaging and fluorescence microscopy of tumors were performed. BxPC-3 tumor showed a higher radioligand binding in SPECT and higher fluorescence intensity as well as a delay in the probe washout in NIR imaging when compared to A4 tumor. The biodistribution profile of 111In-labeled probe, ARG, and IHC confirmed the α6β4 specific binding of the probe. Here, we propose that α6β4 is a desirable target for the diagnosis of pancreatic cancer and that it could be detected by radionuclide imaging and NIR imaging using a radiolabeled or ICG-labeled α6β4 antibody.

  6. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  7. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  8. First experiences from Copenhagen with paediatric single photon emission computed tomography/computed tomography

    DEFF Research Database (Denmark)

    Mortensen, Jann; Bech, Birthe Højlund; Højgaard, Liselotte

    2011-01-01

    OBJECTIVE: This study evaluates the diagnostic value of single photon emission computed tomographic (SPECT)/multislice computed tomographic (MSCT) fusion images compared with planar scintigraphy in children. METHODS: Fifteen children [eight girls, mean age 13 years (range 2-17 years)] who were...

  9. Single photon emission computed tomography/computed tomography of the skull in malignant otitis externa.

    Science.gov (United States)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Kamaleshwaran, Koramadai Karuppusamy; Agrawal, Kanhaiyalal; Gupta, Ashok Kumar; Mittal, Bhagwant Rai

    2012-01-01

    Malignant otitis externa is a severe, rare infective condition of the external auditory canal and skull base. The diagnosis is generally made from a range of clinical, laboratory, and imaging findings. Technetium 99m methylene diphosphonate bone scintigraphy is known to detect osteomyelitis earlier than computed tomography. The authors present a patient with bilateral malignant otitis externa where the extent of skull base involvement was determined on 3-phase bone scintigraphy with single photon emission computed tomography/computed tomography.

  10. Single photon emission computed tomography (SPECT) in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, R.F. [Univ. of Texas Southwestern Medical School, Dallas (United States)

    1991-12-31

    Epilepsy is a common neurologic disorder which has just begun to be studied with single photon emission computerized tomography (SPECT). Epilepsy usually is studied with electroencephalographic (EEG) techniques that demonstrate the physiologic changes that occur during seizures, and with neuroimaging techniques that show the brain structures where seizures originate. Neither method alone has been adequate to describe the pathophysiology of the patient with epilepsy. EEG techniques lack anatomic sensitivity, and there are no structural abnormalities shown by neuroimaging which are specific for epilepsy. Functional imaging (FI) has developed as a physiologic tool with anatomic sensitivity, and SPECT has been promoted as a FI technique because of its potentially wide availability. However, SPECT is early in its development and its clinical utility for epilepsy still has to be demonstrated. To understand this role of SPECT, consideration must be given to the pathophysiology of epilepsy, brain physiology, types of seizure, epileptic syndromes, and the SPECT technique itself. 44 refs., 2 tabs.

  11. Stress-first single photon emission computed myocardial perfusion imaging

    Science.gov (United States)

    Aquino, C I; Scarano, M; Squame, F; Casaburi, G; Nori, S L; Pace, L

    2016-01-01

    Background Myocardial perfusion imaging (MPI) with single photon emission tomography (SPET) is widely used in coronary artery disease evaluation. Recently major dosimetric concerns have arisen. The aim of this study was to evaluate if a pre-test scoring system could predict the results of stress SPET MPI, thus avoiding two radionuclide injections. Methods All consecutive patients (n=309) undergoing SPET MPI during the first 6 months of 2014 constituted the study group. The scoring system is based on these characteristics: age >65 years (1 point), diabetes (2 points), typical chest pain (2 points), congestive heart failure (3 points), abnormal ECG (4 points), male gender (4 points), and documented previous CAD (5 points). The patients were divided on the basis of the prediction score into 3 classes of risk for an abnormal stress-first protocol. Results An abnormal stress SPET MPI was present in 7/31 patients (23%) with a low risk score, in 24/90 (27%) with an intermediate score risk, and in 124/188 (66%) with an high score risk. ROC curve analysis showed good prediction of abnormal stress MPI. Conclusions Our results suggest an appropriate use of a pre-test clinical prediction formula of abnormal stress MPI in a routine clinical setting. PMID:27896227

  12. Radiolabeled cyclic arginine-glycine-aspartic (RGD)-conjugated iron oxide nanoparticles as single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) dual-modality agents for imaging of breast cancer

    Science.gov (United States)

    Deng, Shengming; Zhang, Wei; Zhang, Bin; Hong, Ruoyu; Chen, Qing; Dong, Jiajia; Chen, Yinyiin; Chen, Zhiqiang; Wu, Yiwei

    2015-01-01

    Ultrasmall superparamagnetic iron oxide nanoparticles (USPIOs) modified with a novel cyclic arginine-glycine-aspartate (RGD) peptide were made and radiolabeled as single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) dual-modality agents for imaging of breast cancer. The probe was tested both in vitro and in vivo to determine its receptor targeting efficacy and feasibility for SPECT and MRI. The radiochemical syntheses of 125I-cRGD-USPIO were accomplished with a radiochemical purity of 96.05 ± 0.33 %. High radiochemical stability was found in fresh human serum and in phosphate-buffered saline. The average hydrodynamic size of 125I-cRGD-USPIO determined by dynamic light scattering was 51.3 nm. Results of in vitro experiments verified the specificity of the radiolabeled nanoparticles to tumor cells. Preliminary biodistribution studies of 125I-radiolabeled cRGD-USPIO in Bcap37-bearing nude mice showed that it had long circulation half-life, high tumor uptake, and high initial blood retention with moderate liver uptake. In vivo tumor targeting and uptake of the radiolabeled nanoparticles in mice model were visualized by SPECT and MRI collected at different time points. Our results strongly indicated that the 125I-cRGD-USPIO could be used as a promising bifunctional radiotracer for early clinical tumor detection with high sensitivity and high spatial resolution by SPECT and MRI.

  13. Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography

    Institute of Scientific and Technical Information of China (English)

    Ka-Kit Wong; Arpit Gandhi; Benjamin L Viglianti; Lorraine M Fig; Domenico Rubello; Milton D Gross

    2016-01-01

    AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches using the terms: "SPECT/CT"; "functional anatomic mapping"; "transmission emission tomography"; "parathyroid adenoma"; "thyroid cancer"; "neuroendocrine tumor"; "adrenal"; "pheochromocytoma"; "paraganglioma"; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts(case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology.RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the biodistribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for 99mTc-sestamibi parathyroid scintigraphy and 99mTc-pertechnetate thyroid scintigraphy, 123I- or 131I-radioiodine for staging of differentiated thyroid carcinoma, 111In- and 99mTclabeled somatostatin receptor analogues for detection of neuroendocrine tumors, 131I-norcholesterol(NP-59) scans for assessment of adrenal cortical hyperfunction, and 123I- or 131I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma.CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to

  14. Anti-MUC1 nano-aptamers for triple-negative breast cancer imaging by single-photon emission computed tomography in inducted animals: initial considerations

    Directory of Open Access Journals (Sweden)

    Santos do Carmo F

    2016-12-01

    Full Text Available Fagner Santos do Carmo,1,2 Eduardo Ricci-Junior,3 Cristal Cerqueira-Coutinho,4 Marta de Souza Albernaz,1,5 Emerson Soares Bernardes,6 Sotiris Missailidis,7 Ralph Santos-Oliveira2 1Rio de Janeiro State University, Biology Institute Roberto Alcantara Gomes, 2Brazilian Nuclear Energy Commission, Nuclear Engineering Institute, 3Federal University of Rio de Janeiro, Faculty of Pharmacy, 4Federal University of Rio de Janeiro, Institute of Macromolecules Eloisa Mano, 5University Hospital Clementino Fraga Filho, Federal University of Rio de Janeiro, Rio de Janeiro, 6Instituto de Pesquisas Energéticas e Nucleares, Centro de Radiofarmácia, São Paulo, 7Institute of Technology in Immunobiologics Bio-Manguinhos, Oswaldo Cruz Foundation (Fiocruz, Rio de Janeiro, Brazil Abstract: The early and specific detection of tumors remains a barrier in oncology, especially in cases such as the triple-negative breast cancer (TNBC. To address this gap, aptamers have found an important application in the recognition of tumor biomarkers such as mucin 1 (MUC1. However, there are still some difficulties in the use of aptamer, as their rapid biological clearance makes their use as drugs limited. In this study, the anti-MUC1 aptamer was used as a drug delivery system (DDS for a radioactive polymeric nanoparticle (NP in the imaging of TNBCs. Thus, poly(lactic-co-glycolic acid NPs loaded with the anti-MUC1 aptamer and labeled with technetium-99m were used for a biodistribution study and imaging of TNBC. The results confirmed that the NP was successfully obtained, with a mean size of 262 nm, according to the dynamic light scattering data. The biodistribution assay in induced animal models with TNBC showed that although there was a high capture by intestine (>30%, the DDS developed had a high tumor uptake (5% and with great in vivo imaging properties, corroborating the possibility of use of this DDS as an imaging drug for TNBC. Keywords: aptamer, cancer control, imaging, nuclear

  15. Anti-MUC1 nano-aptamers for triple-negative breast cancer imaging by single-photon emission computed tomography in inducted animals: initial considerations

    Science.gov (United States)

    Santos do Carmo, Fagner; Ricci-Junior, Eduardo; Cerqueira-Coutinho, Cristal; Albernaz, Marta de Souza; Bernardes, Emerson Soares; Missailidis, Sotiris; Santos-Oliveira, Ralph

    2017-01-01

    The early and specific detection of tumors remains a barrier in oncology, especially in cases such as the triple-negative breast cancer (TNBC). To address this gap, aptamers have found an important application in the recognition of tumor biomarkers such as mucin 1 (MUC1). However, there are still some difficulties in the use of aptamer, as their rapid biological clearance makes their use as drugs limited. In this study, the anti-MUC1 aptamer was used as a drug delivery system (DDS) for a radioactive polymeric nanoparticle (NP) in the imaging of TNBCs. Thus, poly(lactic-co-glycolic acid) NPs loaded with the anti-MUC1 aptamer and labeled with technetium-99m were used for a biodistribution study and imaging of TNBC. The results confirmed that the NP was successfully obtained, with a mean size of 262 nm, according to the dynamic light scattering data. The biodistribution assay in induced animal models with TNBC showed that although there was a high capture by intestine (>30%), the DDS developed had a high tumor uptake (5%) and with great in vivo imaging properties, corroborating the possibility of use of this DDS as an imaging drug for TNBC. PMID:28053523

  16. Massively parallel computers for 3D single-photon-emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Butler, C.S.; Miller, M.I. (Washington Univ., St. Louis, MO (United States). Electronic Systems and Signals Research Lab.); Miller, T.R.; Wallis, J.W. (Washington Univ., St. Louis, MO (United States). Edward Mallinckrodt Inst. of Radiology)

    1994-03-01

    Since the introduction of the expectation-maximization (EM) algorithm for generating maximum-likelihood (ML) and maximum a posteriori (MAP) estimates in emission tomography, there have been many investigators applying the ML method. However, almost all of the previous work has been restricted to two-dimensional (2D) reconstructions. The major focus and contribution of this paper is to demonstrate a fully three-dimensional (3D) implementation of the MAP method for single-photon-emission computed tomography (SPECT). The 3D reconstruction exhibits an improvement in resolution when compared to the generation of the series of separate 2D slice reconstructions. (Author).

  17. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...

  18. Single Photon Holographic Qudit Elements for Linear Optical Quantum Computing

    Science.gov (United States)

    2011-05-01

    volume hologram (VH) qubit logic gate. Our simulations were done both at Florida Atlantic University ( FAU ), and at AFRL during the summer by an FAU ...UG student (Chris Tison). We leveraged this AFRL grant and received approval from FAU to purchase a 7 teraflop GPU computer for student training...internship at AFRL. In order to continue this research the FAU Principal Investigator (PI) and United States (US) student were given H-token access to AFRL

  19. Advances in Single-Photon Emission Computed Tomography Hardware and Software.

    Science.gov (United States)

    Piccinelli, Marina; Garcia, Ernest V

    2016-02-01

    Nuclear imaging techniques remain today's most reliable modality for the assessment and quantification of myocardial perfusion. In recent years, the field has experienced tremendous progress both in terms of dedicated cameras for cardiac applications and software techniques for image reconstruction. The most recent advances in single-photon emission computed tomography hardware and software are reviewed, focusing on how these improvements have resulted in an even more powerful diagnostic tool with reduced injected radiation dose and acquisition time.

  20. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  1. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  2. Left ventricular volume determination from single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-02-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.

  3. Corticobasal degeneration: structural and functional MRI and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ukmar, M. [Department of Radiology, University of Trieste (Italy); Moretti, R.; Bava, A. [Department of Physiology and Pathology, University of Trieste (Italy); Torre, P.; Antonello, R.M. [Department of Internal Medicine and Clinical Neurology, University of Trieste (Italy); Longo, R. [Department of Physics, University of Trieste (Italy)

    2003-10-01

    We studied seven patients with corticobasal degeneration (CBD) from a clinical and imaging perspective. We describe the main morphological features of CBD and, using functional MRI, try to define the possible role of the parietal lobe in simple and complex learned motor sequences. We showed decreased activation of the parietal lobe contralateral to the more affected arm, when movements, simple or complex, are performed with that hand. Moreover we found that functional imaging can demonstrate parietal and motor cortex dysfunction before structural, and even single-photon emission computed tomography changes become evident. (orig.)

  4. Single-photon emission computed tomography/computed tomography in brain tumors.

    Science.gov (United States)

    Schillaci, Orazio; Filippi, Luca; Manni, Carlo; Santoni, Riccardo

    2007-01-01

    Anatomic imaging procedures (computed tomography [CT] and magnetic resonance imaging [MRI]) have become essential tools for brain tumor assessment. Functional images (positron emission tomography [PET] and single-photon emission computed tomography [SPECT]) can provide additional information useful during the diagnostic workup to determine the degree of malignancy and as a substitute or guide for biopsy. After surgery and/or radiotherapy, nuclear medicine examinations are essential to assess persistence of tumor, to differentiate recurrence from radiation necrosis and gliosis, and to monitor the disease. The combination of functional images with anatomic ones is of the utmost importance for a full evaluation of these patients, which can be obtained by means of imaging fusion. Despite the fast-growing diffusion of PET, in most cases of brain tumors, SPECT studies are adequate and provide results that parallel those obtained with PET. The main limitation of SPECT imaging with brain tumor-seeking radiopharmaceuticals is the lack of precise anatomic details; this drawback is overcome by the fusion with morphological studies that provide an anatomic map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT or MRI demonstrated usefulness for brain tumor assessment, but this process is often time consuming and not practical for everyday nuclear medicine studies. The recent development of dual-modality integrated imaging systems, which allow the acquisition of SPECT and CT images in the same scanning session, and their co-registration by means of the hardware, has facilitated this process. In SPECT studies of brain tumors with various radiopharmaceuticals, fused images are helpful in providing the precise localization of neoplastic lesions, and in excluding the disease in sites of physiologic tracer uptake. This information is useful for optimizing diagnosis, therapy monitoring, and radiotherapy treatment planning, with a

  5. DE-BLURRING SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGES USING WAVELET DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    Neethu M. Sasi

    2016-02-01

    Full Text Available Single photon emission computed tomography imaging is a popular nuclear medicine imaging technique which generates images by detecting radiations emitted by radioactive isotopes injected in the human body. Scattering of these emitted radiations introduces blur in this type of images. This paper proposes an image processing technique to enhance cardiac single photon emission computed tomography images by reducing the blur in the image. The algorithm works in two main stages. In the first stage a maximum likelihood estimate of the point spread function and the true image is obtained. In the second stage Lucy Richardson algorithm is applied on the selected wavelet coefficients of the true image estimate. The significant contribution of this paper is that processing of images is done in the wavelet domain. Pre-filtering is also done as a sub stage to avoid unwanted ringing effects. Real cardiac images are used for the quantitative and qualitative evaluations of the algorithm. Blur metric, peak signal to noise ratio and Tenengrad criterion are used as quantitative measures. Comparison against other existing de-blurring algorithms is also done. The simulation results indicate that the proposed method effectively reduces blur present in the image.

  6. Statistical parametric mapping in brain single photon computed emission tomography after carbon monoxide intoxication.

    Science.gov (United States)

    Watanabe, N; Nohara, S; Matsuda, H; Sumiya, H; Noguchi, K; Shimizu, M; Tsuji, S; Kinuya, S; Shuke, N; Yokoyama, K; Seto, H

    2002-04-01

    The purpose of this retrospective study was to assess regional cerebral blood flow in patients after carbon monoxide intoxication by using brain single photon emission computed tomography and statistical parametric mapping. Eight patients with delayed neuropsychiatric sequelae and ten patients with no neuropsychiatric symptoms after carbon monoxide intoxication were studied with brain single photon emission tomography imaging with 99mTc-hexamethyl-propyleneamine oxime. Forty-four control subjects were also studied. We used the adjusted regional cerebral blood flow images in relative flow distribution (normalization of global cerebral blood flow for each subject to 50 ml x 100 g(-1) x min(-1) with proportional scaling) to compare these groups with statistical parametric mapping. Using this technique, significantly decreased regional cerebral blood flow was noted extensively in the bilateral frontal lobes as well as the bilateral insula and a part of the right temporal lobe in the patients with delayed neuropsychiatric sequelae as compared with normal volunteers (Pparametric mapping is a useful technique for highlighting differences in regional cerebral blood flow in patients following carbon monoxide intoxication as compared with normal volunteers. The selectively reduced blood flow noted in this investigation supports the contention that the decrease following carbon monoxide intoxication may be prolonged and further worsen in the frontal lobe. In addition, the present study may help to clarify the characteristics of the pathophysiological alteration underlying delayed neuropsychiatric sequelae.

  7. Single photon emission computed tomography/computed tomography for malignant otitis externa: lesion not shown on planar image.

    Science.gov (United States)

    Chen, Yu-Hung; Hsieh, Hung-Jen

    2013-01-01

    Malignant otitis externa is a severe and rare infection of the external acoustic meatus. Triphasic bone and (67)Ga scintigraphies are used to initial detect and follow-up the response of therapy. With single photon emission computed tomography/computed tomography images, the diagnostic sensitivity is higher. We presented a case with malignant otitis externa with initial negative planar scintigraphic finding. The lesion was detected by photon emission computed tomography/computed tomography images. We concluded that the photon emission computed tomography/computed tomography should be performed routinely for patients with suspected malignant otitis externa, even without evidence of lesion on planar images.

  8. Single-photon emission computed tomography in human immunodeficiency virus encephalopathy: A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Masdeu, J.C.; Yudd, A.; Van Heertum, R.L.; Grundman, M.; Hriso, E.; O' Connell, R.A.; Luck, D.; Camli, U.; King, L.N. (St. Vincent' s Medical Center, New York, NY (USA))

    1991-08-01

    Depression or psychosis in a previously asymptomatic individual infected with the human immunodeficiency virus (HIV) may be psychogenic, related to brain involvement by the HIV or both. Although prognosis and treatment differ depending on etiology, computed tomography (CT) and magnetic resonance imaging (MRI) are usually unrevealing in early HIV encephalopathy and therefore cannot differentiate it from psychogenic conditions. Thirty of 32 patients (94%) with HIV encephalopathy had single-photon emission computed tomography (SPECT) findings that differed from the findings in 15 patients with non-HIV psychoses and 6 controls. SPECT showed multifocal cortical and subcortical areas of hypoperfusion. In 4 cases, cognitive improvement after 6-8 weeks of zidovudine (AZT) therapy was reflected in amelioration of SPECT findings. CT remained unchanged. SPECT may be a useful technique for the evaluation of HIV encephalopathy.

  9. Reconstruction Algorithms for Positron Emission Tomography and Single Photon Emission Computed Tomography and their Numerical Implementation

    CERN Document Server

    Fokas, A S; Marinakis, V

    2004-01-01

    The modern imaging techniques of Positron Emission Tomography and of Single Photon Emission Computed Tomography are not only two of the most important tools for studying the functional characteristics of the brain, but they now also play a vital role in several areas of clinical medicine, including neurology, oncology and cardiology. The basic mathematical problems associated with these techniques are the construction of the inverse of the Radon transform and of the inverse of the so called attenuated Radon transform respectively. We first show that, by employing mathematical techniques developed in the theory of nonlinear integrable equations, it is possible to obtain analytic formulas for these two inverse transforms. We then present algorithms for the numerical implementation of these analytic formulas, based on approximating the given data in terms of cubic splines. Several numerical tests are presented which suggest that our algorithms are capable of producing accurate reconstruction for realistic phanto...

  10. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2014-01-01

    Full Text Available We studied the anatomical correlates of reflex hot water epilepsy (HWE using multimodality investigations viz. magnetic resonance imaging (MRI, electroencephalography (EEG, and single photon emission computed tomography (SPECT. Five men (mean age: 27.0 ΁ 5.8 years with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  11. Right parietal stroke with Gerstmann's syndrome. Appearance on computed tomography, magnetic resonance imaging, and single-photon emission computed tomography.

    Science.gov (United States)

    Moore, M R; Saver, J L; Johnson, K A; Romero, J A

    1991-04-01

    We examined a patient who exhibited Gerstmann's syndrome (left-right disorientation, finger agnosia, dyscalculia, and dysgraphia) in association with a perioperative stroke in the right parietal lobe. This is the first description of the Gerstmann tetrad occurring in the setting of discrete right hemisphere pathologic findings. A well-localized vascular lesion was demonstrated by computed tomography, magnetic resonance imaging, and single-photon emission computed tomographic studies. The patient had clinical evidence of reversed functional cerebral dominance and radiologic evidence of reversed anatomic cerebral asymmetries.

  12. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    DEFF Research Database (Denmark)

    Wolf, Paul A.; Jørgensen, Jakob Sauer; Schmidt, Taly G.

    2013-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true...

  13. Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

    Science.gov (United States)

    Islamian, Jalil Pirayesh; Azazrm, AhmadReza; Mahmoudian, Babak; Gharapapagh, Esmail

    2015-01-01

    The collimator in single photon emission computed tomography (SPECT), is an important part of the imaging chain. One of the most important collimators that used in research, preclinical study, small animal, and organ imaging is the pinhole collimator. Pinhole collimator can improve the tradeoff between sensitivity and resolution in comparison with conventional parallel-hole collimator and facilities diagnosis. However, a major problem with pinhole collimator is a small field of view (FOV). Multi-pinhole collimator has been investigated in order to increase the sensitivity and FOV with a preserved spatial resolution. The geometry of pinhole and multi-pinhole collimators is a critical factor in the image quality and plays a key role in SPECT imaging. The issue of the material and geometry for pinhole and multi-pinhole collimators have been a controversial and much disputed subject within the field of SPECT imaging. On the other hand, recent developments in collimator optimization have heightened the need for appropriate reconstruction algorithms for pinhole SPECT imaging. Therefore, iterative reconstruction algorithms were introduced to minimize the undesirable effect on image quality. Current researches have focused on geometry and configuration of pinhole and multi-pinhole collimation rather than reconstruction algorithm. The lofthole and multi-lofthole collimator are samples of novel designs. The purpose of this paper is to provide a review on recent researches in the pinhole and multi-pinhole collimators for SPECT imaging.

  14. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  15. Reversible Electroencephalographic and Single Photon Emission Computed Tomography Abnormalities in Hashimoto's Encephalopathy

    Directory of Open Access Journals (Sweden)

    Po-Lin Chen

    2005-02-01

    Full Text Available Hashimoto's encephalopathy (HE is a well-established disease that occurs most commonly in patients with euthyroidism. We report 3 patients diagnosed with HE. Cases 1 and 2 were young females who had experienced intractable seizures and presented with cognitive impairment. Reversible slow waves on the electroencephalogram (EEG, and nearly complete recovery of cognition, were noted after steroid treatment. Case 3 was an elderly male who presented with a sudden onset of vertigo, diplopia, and recurrent gait ataxia. Reversible hypoperfusion in the upper portion of the left cerebellum, on 99mTc hexamethylpropyleneamine oxime (HMPAO single photon emission computed tomography (SPECT, was noted after steroid treatment. We also review 25 cases from the literature of patients diagnosed with HE. All patients had antithyroid antibodies. A reversible inflammatory process is supported by brain magnetic resonance imaging, SPECT, EEG and cerebrospinal fluid studies. Vasculitis is the most probable pathogenesis according to laboratory findings. Steroids are the treatment of choice, and result in a favorable outcome when administered early in the disease course.

  16. Imaging of lesions in the posterior cranial fossa using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Michiro; Uesugi, Yasuo; Higashikawa, Masahiko; Ochi, Mari; Makimoto, Kazuo; Takahashi, Hiroaki; Shin, Akinori; Utsunomiya, Keita; Akagi, Hiroaki

    1988-10-01

    Lesions in the posterior cranial fossa were visualized by single photon emission computed tomography (SPECT) with /sup 123/I-IMP (N-isopropyl-p-/sup 123/I-iodoamphetamine) and /sup 99m/Tc-HM-PAO (/sup 99m/Tc-hexametylpropyleneamine oxime). It is generally held that these radiopharmaceuticals penetrate the walls of cerebral blood vessels and that their accumulations in the brain tissue may reflect the cerebral blood flow. Six patients with lesions in the central nervous system all showed wider areas of abnormality in SPECT than in X-ray CT, indicating a larger lesion of blood flow disturbance. In the next series of 11 patients with vertigo or dizziness of unknown etiology, eight had abnormal findings in the scan with /sup 123/I-IMP as did four of the nine in the scan with /sup 99m/Tc-HM-PAO. Thus, most patients with dizziness of unknown etiology may have some vertebral blood flow disorder, which in some cases is not clearly diagnosed by conventional vestibular examinations or even by X-ray CT scan. The accuracy of the diagnostic measures for otoneurological problems awaits further studies of their sensitivity and specificity.

  17. Single-photon emission computed tomographic findings and motor neuron signs in amyotrophic lateral sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Terao, Shin-ichi; Sobue, Gen; Higashi, Naoki; Takahashi, Masahiko; Suga, Hidemichi; Mitsuma, Terunori [Aichi Medical Univ., Nagakute (Japan)

    1995-03-01

    {sup 123}I-amphetamine-single photon emission computed tomography (SPECT) was performed on 16 patients with amyotrophic lateral sclerosis (ALS) to investigate the correlation between regional cerebral blood flow (rCBF) and upper motor neuron signs. Significant decreased blood flow less than 2 SDs below the mean of controls was observed in the frontal lobe in 4 patients (25%) and in the frontoparietal lobe including the cortical motor area in 4 patients, respectively. The severity of extermity muscular weakness was significantly correlate with decrease in blood flow through the frontal lobe (p<0.05) and through the frontoparietal lobe (p<0.001). A significant correlation was also noted to exist between the severity of bulbar paralysis and decrease in blood flow through the frontoparietal lobe. No correlation, however, was observed between rCBF and severity of spasticity, presence or absence of Babinski`s sign and the duration of illness. Although muscular weakness in the limbs and bulbar paralysis are not pure upper motor neuron signs, the observed reduction in blood flow through the frontal or frontoparietal lobes appears to reflect extensive progression of functional or organic lesions of cortical neurons including the motor area. (author).

  18. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  19. Brain Single Photon Emission Computed Tomography in Anosmic Subjects Ater Closed Head Trauma

    Directory of Open Access Journals (Sweden)

    Roozbeh Banan

    2011-01-01

    Full Text Available Anosmia following head trauma is relatively common and in many cases is persistent and irreversible. The ability to objectively measure such a decline in smelling, for both clinical and medicolegal goals, is very important. The aim of this study was to find results of brain Single Photon Emission Computed Tomography (SPECT in anosmic subjects after closed head trauma. This case-control cross sectional study was conducted in a tertiary referral University Hospital. The brain perfusion state of nineteen anosmic patients and thirteen normal controls was evaluated by means of the SPECT with 99mtc- ECD infusion- before and after olfactory stimulation. The orbitofrontal lobe of the brain was assumed as the region of interest and changes in perfusion of this area before and after the stimulations were compared in two groups. The mean of brain perfusion in controls before and after the stimulation was 8.26% ± 0.19% and 9.89% ± 0.54%, respectively (P < 0.0001. Among patients group, these quantities were 7.97% ± 1.05% and 8.49% ± 1.5%, respectively (P < 0.004. The difference between all the measures in cases and controls were statistically significant (P < 0.0001. There were no differences in age and sex between two groups. The brain SPECT is an objective technique suitable for evaluating anosmia following the head trauma and it may be used with other diagnostic modalities

  20. A study of cerebral perfusion using single photon emission computed tomography in neonates with brain lesions

    Energy Technology Data Exchange (ETDEWEB)

    Haddad, J.; Contantinesco, A.; Brunot, B.; Messer, J. (Hospital Universitaire de Strasbourg (France))

    1994-03-01

    In this study the authors used a single photon emission computed tomography technique (SPECT) with radiolabelled [sup 99m]Tc HMPAO to assess cerebral perfusion in newborn infants with documented cerebral lesions and to determine to what extent brain SPECT might be useful in the neonatal period. A total of 15 newborn infants with the following cerebral pathologies were enrolled: severe parietal bilateral periventricular leucomalacia; moderate parietal bilateral PVL; intraventricular haemorrhage grade II with unilateral parietal parenchymal extension; cerebral infarction in the zone of middle cerebral artery; and post-haemorrhagic hydrocephalus. Follow-up was available in all infants. Alterations in cerebral perfusion were seen in only 12 of 15 infants and at the location of severe PVL, PE and CI. It was noted that the regions of diminished perfusion extended beyond the apparent extent of cerebral pathology delineated by ultrasound or magnetic resonance imaging. Markedly diminished perfusion was seen in one infant with hydrocephalus, which recovered following placement of ventriculo-peritoneal shunt. Regarding outcome, SPECT data failed to provide additional information than that of neuroradiological investigations. It is concluded that the use of SPECT, under these conditions, to assess alteration of cerebral perfusion in the neonatal period will not provide any additional information than that of neuroradiological investigations. 17 refs., 3 figs., 1 tab.

  1. [Analysis of single-photon emission computed tomography in patients with hypertensive encephalopathy complicated with previous hypertensive crisis].

    Science.gov (United States)

    Kustkova, H S

    2012-01-01

    In cerebrovascular diseases pefuzionnaya single photon emission computed tomography with lipophilic amines used for the diagnosis of functional disorders of cerebral blood flow. Quantitative calculations helps clarify the nature of vascular disease and clarify the adequacy and effectiveness of the treatment. In this modern program for SPECT ensure conduct not only as to the calculation of blood flow, but also make it possible to compute also the absolute values of cerebral blood flow.

  2. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  3. A Study on Determination of an Optimized Detector for Single Photon Emission Computed Tomography.

    Science.gov (United States)

    Khoshakhlagh, Mohammad; Islamian, Jalil Pirayesh; Abedi, Mohammad; Mahmoudian, Babak; Mardanshahi, Ali Reza

    2016-01-01

    The detector is a critical component of the single photon emission computed tomography (SPECT) imaging system for giving accurate information from the exact pattern of radionuclide distribution in the target organ. The SIMIND Monte Carlo program was utilized for the simulation of a Siemen's dual head variable angle SPECT imaging system with a low energy high resolution (LEHR) collimator. The Planar and SPECT scans for a (99m)Tc point source and a Jaszczak Phantom with the both experiment and simulated systems were prepared and after verification and validation of the simulated system, the similar scans of the phantoms were compared (from the point of view of the images' quality), namely, the simulated system with the detectors including bismuth germanate (BGO), yttrium aluminum garnet (YAG:Ce), Cerium-doped yttrium aluminum garnet (YAG:Ce), yttrium aluminum perovslite (YAP:Ce), lutetium aluminum garnet (LuAG:Ce), cerium activated lanthanum bromide (LaBr3), cadmium zinc telluride (CZT), and sodium iodide activated with thallium [NaI(Tl)]. The parameters of full width at half maximum (FWHM), energy and special resolution, sensitivity, and also the comparison of images' quality by the structural similarity (SSIM) algorithm with the Zhou Wang and Rouse/Hemami methods were analyzed. FWHMs for the crystals were calculated at 13.895, 14.321, 14.310, 14.322, 14.184, and 14.312 keV and the related energy resolutions obtained 9.854, 10.229, 10.221, 10.230, 10.131, and 10.223 %, respectively. Finally, SSIM indexes for comparison of the phantom images were calculated at 0.22172, 0.16326, 0.18135, 0.17301, 0.18412, and 0.20433 as compared to NaI(Tl). The results showed that BGO and LuAG: Ce crystals have high sensitivity and resolution, and better image quality as compared to other scintillation crystals.

  4. SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY STUDY OF REGIONAL CEREBRAL BLOOD FLOW IN PATIENTS WITH HEMISPATIAL NEGLECT

    Institute of Scientific and Technical Information of China (English)

    尹雅芙; 任艳; 李亚明

    2003-01-01

    Objective.To explore the correlations between the occurrence and severity of neglect and the region,range or extent of the decrease in regional cerebral blood flow(rCBF). Methods. Nineteen dextromanual patients who were diagnosed as unilateral stroke clinically and hemispatial neglect by a neglect test battery received single photon emission computed tomography(SPECT) scans. Results. On images,the damages of patients with neglect were seen most frequently in the frontal cortex,and then in turn in the parietal cortex,occipital cortex,temporal cortex,basal ganglia and thalamus. Most patients with neglect had two or more regions damaged. The most significant region was temporal-parietal-occipi-tal(TPO)junction. The correlation coefficient between rCBF and the severity of neglect was -0.34(t=-1.5,P>0.05),and that between the decrease percentage of rCBF and the severity of neglect was 0.34(t=1.47,P>0.05). The correlation coefficients between the range,number of foci,the flow deficit size and the severity of neglect were 0.71(t=4.13,P<0.01),0.70(t=4.07,P<0.01)and 0.64(t=3.40, P<0.01),respectively. Conclusions. The severity of neglect correlates with rCBF and the decrease percentage of rCBF insignificantly,but correlates positively with the range,number of foci and the flow deficit size significantly. Hemispatial neglect is caused by the damage of multiple sites and combined damage results in more severe neglect.

  5. Development of correction methods for variable pinhole single-photon emission computed tomography

    Science.gov (United States)

    Bae, S.; Bae, J.; Lee, H.; Lee, K.

    2016-02-01

    We propose a novel pinhole collimator in which the pinhole shape can be changed in real-time, and a new single-photon emission computed tomography (SPECT) system that utilizes this variable pinhole (VP) collimator. The acceptance angle and distance between the collimator and the object of VP SPECT are varied so that the optimum value of the region-of-interest (ROI) can be obtained for each rotation angle. Because of these geometrical variations, new correction methods are required for image reconstruction. In this study, we developed two correction methods. The first is the sensitivity-correction algorithm, which minimizes the variation of a system matrix caused by varying the acceptance angle for each rotation angle. The second is the acquisition-time-correction method, which reduces the variation of uniformity caused by varying the distance between the collimator and the object for each rotation angle. A 3D maximum likelihood expectation maximization (MLEM) algorithm was applied to image reconstruction, and two digital phantoms were studied to evaluate the resolution and sensitivity of the images obtained using the proposed methods. The images obtained by using the proposed correction methods show higher uniformity and resolution than those obtained without using these methods. In particular, the results of the resolution phantom study show that hot rods (0.8-mm-diameter) can be clearly distinguished using the proposed correction methods. A quantitative analysis of the ROI phantom revealed that the mean square error (MSE) was 0.42 without the acquisition-time-correction method, and 0.04 with the acquisition-time-correction method. The MSEs of the resolution phantom without and with the acquisition-time-correction method were calculated as 55.14 and 14.69, respectively.

  6. Single-photon emission computed tomography and positron-emission tomography assays for tissue oxygenation.

    Science.gov (United States)

    Chapman, J D; Schneider, R F; Urbain, J L; Hanks, G E

    2001-01-01

    Radiotherapy prescription can now be customized to target the major mechanism(s) of resistance of individual tumors. In that regard, functional imaging techniques should be exploited to identify the dominant mechanism(s). Tumor biology research has identified several mechanisms of tumor resistance that may be unique to radiation treatments. These fall into 3 broad areas associated with (1) tumor hypoxic fraction, (2) tumor growth rate, (3) and the intrinsic radiosensitivity of tumor clonogens. Imaging research has markers in various stages of development for quantifying relevant information about each of these mechanisms, and those that measure tumor oxygenation and predict for radioresistance are the most advanced. Positron-emission tomography (PET) measurement of oxygen 15 has yielded important information, particularly about brain tissue perfusion, metabolism, and function. Indirect markers of tumor hypoxia have exploited the covalent binding of bioreductive intermediates of azomycin-containing compounds whose uptakes are inversely proportional to intracellular oxygen concentrations. Pilot clinical studies with single-photon emission computed tomography (SPECT) and PET detection of radiolabeled markers to tumor hypoxia have been reported. Recently, other studies have attempted to exploit the reduction properties of both technetium and copper chelates for the selective deposition of radioactive metals in hypoxic tissues. A growing number of potentially useful isotopes are now available for labeling several novel chemicals that could have the appropriate specificity and sensitivity. Preclinical studies with "microSPECT" and "microPET" will be important to define the optimal radiodiagnostic(s) for measuring tissue oxygenation and for determining the time after their administration for optimal hypoxic signal acquisition. Radiolabeled markers of growth kinetics and intrinsic radiosensitivity of cells in solid tumors are also being developed. We conclude that

  7. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almquist, H

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correctionwere artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 {+-} 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer {sup 133}Xe. Because of the low energy of {sup 133}Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study.

  8. An x-ray-based capsule for colorectal cancer screening incorporating single photon counting technology

    Science.gov (United States)

    Lifshitz, Ronen; Kimchy, Yoav; Gelbard, Nir; Leibushor, Avi; Golan, Oleg; Elgali, Avner; Hassoon, Salah; Kaplan, Max; Smirnov, Michael; Shpigelman, Boaz; Bar-Ilan, Omer; Rubin, Daniel; Ovadia, Alex

    2017-03-01

    An ingestible capsule for colorectal cancer screening, based on ionizing-radiation imaging, has been developed and is in advanced stages of system stabilization and clinical evaluation. The imaging principle allows future patients using this technology to avoid bowel cleansing, and to continue the normal life routine during procedure. The Check-Cap capsule, or C-Scan ® Cap, imaging principle is essentially based on reconstructing scattered radiation, while both radiation source and radiation detectors reside within the capsule. The radiation source is a custom-made radioisotope encased in a small canister, collimated into rotating beams. While traveling along the human colon, irradiation occurs from within the capsule towards the colon wall. Scattering of radiation occurs both inside and outside the colon segment; some of this radiation is scattered back and detected by sensors onboard the capsule. During procedure, the patient receives small amounts of contrast agent as an addition to his/her normal diet. The presence of contrast agent inside the colon dictates the dominant physical processes to become Compton Scattering and X-Ray Fluorescence (XRF), which differ mainly by the energy of scattered photons. The detector readout electronics incorporates low-noise Single Photon Counting channels, allowing separation between the products of these different physical processes. Separating between radiation energies essentially allows estimation of the distance from the capsule to the colon wall, hence structural imaging of the intraluminal surface. This allows imaging of structural protrusions into the colon volume, especially focusing on adenomas that may develop into colorectal cancer.

  9. Evaluating image denoising methods in myocardial perfusion single photon emission computed tomography (SPECT) imaging

    Science.gov (United States)

    Skiadopoulos, S.; Karatrantou, A.; Korfiatis, P.; Costaridou, L.; Vassilakos, P.; Apostolopoulos, D.; Panayiotakis, G.

    2009-10-01

    The statistical nature of single photon emission computed tomography (SPECT) imaging, due to the Poisson noise effect, results in the degradation of image quality, especially in the case of lesions of low signal-to-noise ratio (SNR). A variety of well-established single-scale denoising methods applied on projection raw images have been incorporated in SPECT imaging applications, while multi-scale denoising methods with promising performance have been proposed. In this paper, a comparative evaluation study is performed between a multi-scale platelet denoising method and the well-established Butterworth filter applied as a pre- and post-processing step on images reconstructed without and/or with attenuation correction. Quantitative evaluation was carried out employing (i) a cardiac phantom containing two different size cold defects, utilized in two experiments conducted to simulate conditions without and with photon attenuation from myocardial surrounding tissue and (ii) a pilot-verified clinical dataset of 15 patients with ischemic defects. Image noise, defect contrast, SNR and defect contrast-to-noise ratio (CNR) metrics were computed for both phantom and patient defects. In addition, an observer preference study was carried out for the clinical dataset, based on rankings from two nuclear medicine clinicians. Without photon attenuation conditions, denoising by platelet and Butterworth post-processing methods outperformed Butterworth pre-processing for large size defects, while for small size defects, as well as with photon attenuation conditions, all methods have demonstrated similar denoising performance. Under both attenuation conditions, the platelet method showed improved performance with respect to defect contrast, SNR and defect CNR in the case of images reconstructed without attenuation correction, however not statistically significant (p > 0.05). Quantitative as well as preference results obtained from clinical data showed similar performance of the

  10. Image Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Bahreyni Toossi

    2010-06-01

    Full Text Available Introduction: In Single Photon Emission Computed Tomography (SPECT, the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SPECT system is a convenient method to assess the impact of these factors on the image quality. Materials and Methods: The SIMIND Monte Carlo program was employed to simulate a Siemens E.CAM SPECT system. Verification of the simulation was performed by comparing the performance parameters of the system. The verified system was used for SPECT simulations of homogenous and inhomogeneous voxelized phantoms in conjugation with hardware modifications. The resulting data were compared with those obtained from the simulated system without any modifications. Image quality was assessed by comparing the Structural SIMularity index (SSIM, contrast, and resolution of images. Results: The energy spectra acquired from both simulated and real SPECT systems demonstrated similar energy peak regions. The resulting full-widths-at-half-maximums were 13.92 keV for the simulation and 13.58 keV for experimental data, corresponding to energy resolutions of 9.95% and 9.61%, and with calculated sensitivities of 85.39 and 85.11 cps/MBq, respectively. Better performance parameters were obtained with a hardware-modified system constructed using a 0.944 cm thickness NaI(Tl crystal covered by a layer of 0.24 cm aluminum, a  slat of 4.5 cm Pyrex as a backscattering medium, and a parallel hole collimator of Pb-Sb alloy with 2.405 cm thickness. Conclusion: The modeling of a Siemens E.CAM SPECT system was performed with the SIMIND Monte Carlo code. Results obtained with the code are in good agreement with experimental results. The findings demonstrate that the proposed hardware modifications

  11. Single photon emission computed tomography (SPECT of anxiety disorders before and after treatment with citalopram

    Directory of Open Access Journals (Sweden)

    Seedat Soraya

    2004-10-01

    Full Text Available Abstract Background Several studies have now examined the effects of selective serotonin reuptake inhibitor (SSRI treatment on brain function in a variety of anxiety disorders including obsessive-compulsive disorder (OCD, posttraumatic stress disorder (PTSD, and social anxiety disorder (social phobia (SAD. Regional changes in cerebral perfusion following SSRI treatment have been shown for all three disorders. The orbitofrontal cortex (OFC (OCD, caudate (OCD, medial pre-frontal/cingulate (OCD, SAD, PTSD, temporal (OCD, SAD, PTSD and, thalamic regions (OCD, SAD are some of those implicated. Some data also suggests that higher perfusion pre-treatment in the anterior cingulate (PTSD, OFC, caudate (OCD and antero-lateral temporal region (SAD predicts subsequent treatment response. This paper further examines the notion of overlap in the neurocircuitry of treatment and indeed treatment response across anxiety disorders with SSRI treatment. Methods Single photon emission computed tomography (SPECT using Tc-99 m HMPAO to assess brain perfusion was performed on subjects with OCD, PTSD, and SAD before and after 8 weeks (SAD and 12 weeks (OCD and PTSD treatment with the SSRI citalopram. Statistical parametric mapping (SPM was used to compare scans (pre- vs post-medication, and responders vs non-responders in the combined group of subjects. Results Citalopram treatment resulted in significant deactivation (p = 0.001 for the entire group in the superior (t = 4.78 and anterior (t = 4.04 cingulate, right thalamus (t = 4.66 and left hippocampus (t = 3.96. Deactivation (p = 0.001 within the left precentral (t = 4.26, right mid-frontal (t = 4.03, right inferior frontal (t = 3.99, left prefrontal (3.81 and right precuneus (t= 3.85 was more marked in treatment responders. No pattern of baseline activation distinguished responders from non-responders to subsequent pharmacotherapy. Conclusions Although each of the anxiety disorders may be mediated by different

  12. Two Cases of Legionella pneumophila Pneumonia with Prolonged Neurologic Symptoms and Brain Hypoperfusion on Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hiromitsu Ohta

    2016-01-01

    Full Text Available Cerebral and cerebellar symptoms are frequently associated with Legionnaires’ disease. However, corresponding brain lesions are difficult to demonstrate using either computed tomography (CT or magnetic resonance imaging (MRI. We report here two patients with Legionella pneumophila pneumonia accompanied by prolonged neurologic symptoms. In contrast to brain CT and MRI, which failed to detect any abnormalities, single-photon emission computed tomography (SPECT showed multiple sites of hypoperfusion within the brains of both patients. These cases suggest that vasculopathy, which is detectable by SPECT, might be one of the causes of neurologic symptoms in patients with Legionnaires’ disease.

  13. Domestic Development of Single-Photon Emission Computed Tomography (SPECT) Unit with Detector based on Silicon Photomultipliers

    Science.gov (United States)

    Grishakov, S.; Ryzhikova, O.; Sergienko, V.; Ansheles, A.; Novikov, S.

    2017-01-01

    The idea of creating a single-photon emission computed tomography unit with solid-state photomultipliers is not new [1], as the problems of analog-to-digital conversion with a lot of noise and a wide range of values of intrinsic spatial resolution of the detector in a center and relevant fields of view could not be solved by means of gamma-camera detector architectures based on vacuum photomultipliers. This paper offers a new SPECT imaging solution that is free from these problems.

  14. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  15. 99mTc-methylene diphosphonate single-photon emission computed tomography/computed tomography improves the diagnostic accuracy of osteoid osteoma

    Science.gov (United States)

    Squier, Samuel Brian; Lewis, Jacob Ian; Accurso, Joseph Matthew; Jain, Manoj Kumar

    2016-01-01

    We present a case of a 17-year-old football player who had previously received multiple facet joint injections for presumed secondary osteoarthritis. 99mTc-methylene diphosphonate single-photon emission computed tomography/computed tomography imaging of the cervical spine demonstrated focal increased radiopharmaceutical activity in the right C2 lamina, which was associated with an osteolytic lesion with a central irregular sclerotic nidus. Surgical pathology confirmed an osteoid osteoma. PMID:27833319

  16. Left leg apraxia after anterior cerebral artery territory infarction: functional analysis using single-photon emission computed tomography.

    Science.gov (United States)

    Ito, Ikuno; Ito, Kimiteru; Shindo, Naoko

    2013-01-01

    Left hand apraxia is known as a unique symptom of callosal apraxia, but lower limb symptoms are rarely mentioned. We report a patient who experienced left ideomotor apraxia affecting both the upper and lower limbs after a stroke in the territory of the right anterior cerebral artery. His spontaneous gait was normal, but he was unable to move his left leg intentionally either by verbal command or by imitation. His leg symptoms gradually improved over time. We evaluated the change in cerebral blood flow in this patient using single-photon emission computed tomography. The results showed an increase in blood flow in the posterior corpus callosum; therefore, we suggested that the callosal pathway might contribute to left leg as well as left hand volitional movement. Copyright © 2013 S. Karger AG, Basel.

  17. Single photon emission computed tomography with [sup 123]I-IMP in three cases of the neuroleptic malignant syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Nisijima, K. (Dept. of Psychiatry, Jichi Medical School, Tochigi-Ken (Japan)); Matoba, M. (Dept. of Psychiatry, Jichi Medical School, Tochigi-Ken (Japan)); Ishiguro, T. (Dept. of Psychiatry, Jichi Medical School, Tochigi-Ken (Japan))

    1994-05-01

    Single photon emission computed tomography (SPECT) perfusion brain scans using [sup 123]I-N-isopropyl-p-iodoamphetamine ([sup 123]I-IMP) were performed in three patients with the neuroleptic malignant syndrome (NMS). In two accumulation was increased in the left basal ganglia and decreased in the right on the early images during the active phase of NMS; this asymmetry was not seen after recovery. In the third patient two examinations were performed during the active phase; on the first, increased accumulation of [sup 123]I-IMP in the left basal ganglia was found on the early images, but on the second, increased accumulation of tracer was found in the right basal ganglia on the delayed images. These abnormalities disappeared after improvement of the NMS. These results suggest that a disturbance in the basal ganglia is related to the development of NMS. (orig.)

  18. Use of fuzzy edge single-photon emission computed tomography analysis in definite Alzheimer's disease - a retrospective study

    Directory of Open Access Journals (Sweden)

    Rusina Robert

    2010-09-01

    Full Text Available Abstract Background Definite Alzheimer's disease (AD requires neuropathological confirmation. Single-photon emission computed tomography (SPECT may enhance diagnostic accuracy, but due to restricted sensitivity and specificity, the role of SPECT is largely limited with regard to this purpose. Methods We propose a new method of SPECT data analysis. The method is based on a combination of parietal lobe selection (as regions-of-interest (ROI, 3D fuzzy edge detection, and 3D watershed transformation. We applied the algorithm to three-dimensional SPECT images of human brains and compared the number of watershed regions inside the ROI between AD patients and controls. The Student's two-sample t-test was used for testing domain number equity in both groups. Results AD patients had a significantly reduced number of watershed regions compared to controls (p Conclusions Our non-invasive, relatively low-cost, and easy method can contribute to a more precise diagnosis of AD.

  19. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    CERN Document Server

    Wolf, Paul A; Schmidt, Taly G; Sidky, Emil Y

    2012-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true object in the noiseless case, projection data were generated from an object assuming this model and using the system matrix. Monte Carlo simulations were performed to provide more realistic data of a phantom with varying smoothness across the field of view. Reconstructions were performed across a sweep of two primary design parameters. The results demonstrate that the algorithm recovers the object in a noiseless simulation case. While the algorithm assumes a specific blurring model, the results suggest that the algorithm may provide high reconstruction accuracy even when the object does not match the assumed blurring model. Generally, increased values of the blurring parameter and TV weighting parameters reduced noi...

  20. New Imaging Kit for Assessment of Estrogen Receptors with Single Photon Emission Computed Tomography

    Science.gov (United States)

    2006-09-01

    3Department of Obstetrics and Gynecology 1,2The University of Texas M. D. Anderson Cancer Center, Houston, Texas and 3Taipei Medical University...age are affected. Symptoms may include dysmenorrhea, pelvic pain, abdominal swelling associated with tenesmus and infertility . Despite there were...of women with pelvic endometriosis presenting with chronic pelvic pain or infertility . Fertil Steril 1997;67:238-43. 18 Submitted to Cancer

  1. Value of I-123-subtraction and single-photon emission computed tomography in addition to planar Tc-99m-MIBI scintigraphy before parathyroid surgery

    NARCIS (Netherlands)

    Jorna, Francisca H.; Jager, Pieter L.; Que, Tjin H.; Lemstra, Clara; Plukker, John T. M.

    2007-01-01

    Purpose. To find out if single-photon emission computed tomography (SPECT) and I-123-subtraction can enhance the findings of Tc-99-methoxyisobutylisonitrile (MIBI) scintigraphy for the preoperative localization of parathyroid (PT) tumors. Methods. Among the 111 consecutive patients who underwent pre

  2. Influence of respiratory gating, image filtering, and animal positioning on high-resolution electrocardiography-gated murine cardiac single-photon emission computed tomography

    NARCIS (Netherlands)

    Wu, Chao; Vaissier, Pieter E. B.; Vastenhouw, Brendan; de Jong, Johan R.; Slart, Riemer H. J. A.; Beekman, Freek J.

    2015-01-01

    Cardiac parameters obtained from single-photon emission computed tomographic (SPECT) images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were inject

  3. Assessment of neuroinflammation and microglial activation in Alzheimer's disease with radiolabelled PK11195 and single photon emission computed tomography - A Pilot Study

    NARCIS (Netherlands)

    Versijpt, JJ; Dumont, F; Van Laere, KJ; Decoo, D; Santens, P; Audenaert, K; Achten, E; Slegers, G; Dierckx, RA; Korf, J

    2003-01-01

    Objectives: Inflammation contributes to degeneration in Alzheimer's disease (AD), not simply as a secondary phenomenon, but primarily as a significant source of pathology. [I-123]iodo-PK11195 is a single photon emission computed tomography (SPECT) ligand for the peripheral benzodiazepine receptor, t

  4. In vivo measurement of haloperidol affinity to dopamine D2/D3 receptors by [123I]IBZM and single photon emission computed tomography

    DEFF Research Database (Denmark)

    Videbaek, C; Toska, K; Friberg, L

    2001-01-01

    This study examines the feasibility of a steady-state bolus-integration method with the dopamine D2/D3 receptor single photon emission computer tomography (SPECT) tracer, [123I]IBZM, for determination of in vivo affinity of haloperidol. The nonspecific binding of [123I]IBZM was examined in the rat...

  5. Benzodiazepine receptor equilibrium constants for flumazenil and midazolam determined in humans with the single photon emission computer tomography tracer [123I]iomazenil

    DEFF Research Database (Denmark)

    Videbaek, C; Friberg, L; Holm, S

    1993-01-01

    twice, once without receptor blockade and once with a constant degree of partial blockade of the benzodiazepine receptors by infusion of nonradioactive flumazenil (Lanexat) or midazolam (Dormicum). Single photon emission computer tomography and blood sampling were performed intermittently for 6 h after...

  6. Effect of beta blockade on single photon emission computed tomographic (SPECT) thallium-201 images in patients with coronary disease

    Energy Technology Data Exchange (ETDEWEB)

    Narahara, K.A.; Thompson, C.J.; Hazen, J.F.; Brizendine, M.; Mena, I.

    1989-05-01

    We evaluated the effect of beta blockers on thallium-201 (Tl-201) single photon emission computed tomographic (SPECT) imaging in 12 patients with coronary disease using an automated computer algorithm. Maximal exercise heart rate and blood pressure were reduced and exercise time was increased with beta blockers. Estimated stress defect size decreased from 47 +/- 36.3 gm during placebo treatment to 32 +/- 27.1 gm during beta blocker therapy (-32%; p less than 0.01). The placebo treatment redistribution defect was estimated to be 28 +/- 29.8 gm. It fell to 15 +/- 23.3 gm with beta blockade (-46%; p less than 0.005). All patients had a stress Tl-201 defect during placebo treatment and eight had redistribution defects consistent with residual scar. During beta blocker therapy, 2 of 12 patients had normal stress-redistribution studies and only five patients had redistribution defects. Beta blockade can reduce exercise and redistribution Tl-201 SPECT defect size significantly while simultaneously increasing exercise time and reducing angina. Beta blockers may unmask or may eliminate evidence of redistribution. Tl-201 SPECT imaging may be useful in defining the reduction in ischemia produced by cardiac drugs.

  7. Intracranial blood flow measured with single photon emission computer tomography (SPECT) during transient -6 degrees head-down tilt.

    Science.gov (United States)

    Satake, H; Konishi, T; Kawashima, T; Matsunami, K; Uno, T; Imai, S; Yamada, H; Hirakawa, C

    1994-02-01

    Regional cerebral blood flow (CBF) during a transient head-down tilt of -6 degrees (-6 degrees HDT) was measured with single photon emission computer tomography (SPECT). CBF was measured and averaged for both sides of the brain areas; e.g., the bilateral anterior cerebral artery (bACA) area, the middle cerebral artery (bMCA) area, the posterior cerebral artery (bPCA) area, bilateral basal ganglia, and the cerebellum. Among these areas, a significant increase in CBF was observed in the basal ganglia and the cerebellum during -6 degrees HDT compared to pre-HDT. When CBF was measured separately in the left or right brain area, these significances disappeared, although a trend of increase or decrease was still observable. A trend of increase was observed in the left anterior cerebral artery (IACA) area, the right middle cerebral artery (rMCA) area, the right posterior cerebral artery (rPCA) area, the left and right basal ganglia, and the cerebellum. In rACA, IMCA and IPCA areas, a slight decrease in CBF was observed. At the same time, cardiac parameters were measured. Heart rate (HR), stroke volume (SV) and cardiac output (CO) did not change significantly, although SV slightly increased and HR slightly decreased during -6 degrees HDT.

  8. Magnetic Resonance Spectroscopy and Single-Photon Emission Computed Tomography in the Evaluation of Cerebral Tumors: A Case Report

    Science.gov (United States)

    Siasios, Ioannis; Valotassiou, Varvara; Kapsalaki, Eftychia; Tsougos, Ioannis; Georgoulias, Panagiotis; Fotiadou, Aggeliki; Ioannou, Maria; Koukoulis, Georgios; Dimopoulos, Vassilios; Fountas, Kostas

    2017-01-01

    In their daily clinical practice, physicians have to confront diagnostic dilemmas which cannot be resolved by the application of only one imaging technique. In this case report, we present a 66-year-old woman who was admitted to our institution for the surgical resection of a recently diagnosed brain tumor. The patient had a history of epileptic seizures and was hospitalized in the past for anti-phospholipid syndrome related to a non-Hodgkin lymphoma in remission. Magnetic resonance imaging (MRI) examination revealed an enhancing right parasagittal lesion with significant edema suggestive of a high grade glioma. Advanced MRI techniques including proton magnetic resonance spectroscopy (1H-MRS) showed findings compatible of glioma. An additional examination was performed as part of a protocol that we are routinely performing in our institution for all brain tumors including not only the gold standard advanced MRI techniques but also single-photon emission computed tomography (SPECT) with technetium-99m (Tc99m). Brain SPECT indicated the presence of a meningioma which was verified by the histopathology of the resected specimen. In conclusion, a multimodality approach for the pre-surgical assessment of brain tumors has significant advantages not only for the diagnosis but also for the evaluation of intracranial tumors histology. PMID:27924180

  9. Primary lymphedema of the lower limb: The clinical utility of single photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, Mayo; Baumeister, Ruedinger G. H.; Frick, Andreas; Wallmichrath, Jens; Bartenstein, Peter; Rominger, Axel [Ludwig-Maximilians-University of Munich, Muenchen (Germany)

    2015-02-15

    The aim of this prospective study was to determine whether the additional use of the single photon emission computed tomography/CT (SPECT/CT) technique improves the diagnostic value of planar lymphoscintigraphy in patients presenting with primary lymph edema of the lower limb. For a defined period of three years (April 2011-April 2014) a total of 34 consecutive patients (28 females; age range, 27-83 years) presenting with swelling of the leg(s) suspicious of (uni- or bilateral, proximal or distal) primary lymphedema were prospectively examined by planar lymphoscintigraphy (lower limbs, n = 67) and the tomographic SPECT/CT technique (anatomical sides, n = 65). In comparison to pathological planar scintigraphic findings, the addition of SPECT/CT provided relevant additional information regarding the presence of dermal backflow (86%), the anatomical extent of lymphatic disorders (64%), the presence or absence of lymph nodes (46%), and the visualization of lymph vessels (4%). As an adjunct to planar lymphoscintigraphy, SPECT/CT specifies the anatomical correlation of lymphatic disorders and thus improves assessment of the extent of pathology due to the particular advantages of tomographic separation of overlapping sources. The interpretation of scintigraphic data benefits not only in baseline diagnosis, but also in physiotherapeutical and microsurgical treatments of primary lymphedema.

  10. The clinical meaning of gastric-wall hyperactivity observed on sestamibi cardiac single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cote, C.; Dumont, M. [Centre Hospitalier Universitaire de Quebec, Dept. of Nuclear Medicine, Quebec, Quebec (Canada)]. E-mail: christian.cote@chuq.qc.ca

    2004-06-01

    To evaluate prospectively the incidence and clinical meaning, if any, of gastric-wall hyperactivity observed on sestamibi cardiac single-photon emission computed tomography (SPECT). This phenomenon is completely different from the well-known intraluminal gastric reflux of sestamibi. A group of 819 patients who underwent sestamibi cardiac SPECT was studied from January 2000 to October 2000. Gastric-wall activity was graded qualitatively. Only patients with gastric-wall activity near or equivalent to their heart activity were considered for subsequent analysis. The medical records of patient candidates were reviewed, and their family physicians were asked to respond to a questionnaire by telephone when further information was needed. We identified 13 patients with significant gastric-wall hyperactivity, which was more intense on rest images. Our review of the clinical data shows that all these patients were suffering from dyspepsia and were taking gastric medication. These 13 cases were assigned to 3 groups: gastroesophageal reflux, chronic functional dyspepsia and nonspecific gastritis. Significant gastric-wall hyperactivity is an infrequent observation on sestamibi cardiac SPECT. Our results indicate that the presence of significant gastric-wall hyperactivity is associated with dyspepsia. It is important to realize that this gastric-wall hyperactivity by its proximity to the inferior myocardial wall could in some circumstances lead to either false-negative or false-positive findings, representing a diagnostic problem. Although infrequent, this situation could be avoided by proper quality control, including a systematic review of the raw cine data before reading the images. (author)

  11. Dual-isotope single-photon emission computed tomography for dopamine and serotonin transporters in normal and parkinsonian monkey brains

    Energy Technology Data Exchange (ETDEWEB)

    Li, I-H. [Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei 114, Taiwan (China); Huang, W.-S. [Department of Nuclear Medicine, Tri-Service General Hospital, Taipei, 114, Taiwan (China); Yeh, C.-B. [Department of Psychiatry, Tri-Service General Hospital, Taipei, 114, Taiwan (China); Liao, M.-H.; Chen, C.-C.; Shen, L.-H. [Division of Isotope Application, Institute of Nuclear Energy Research, Taoyaun, 325 Taiwan (China); Liu, J.-C. [Department of Biology and Anatomy, National Defense Medical Center, Taipei 114, Taiwan (China); Ma, K.-H. [Department of Biology and Anatomy, National Defense Medical Center, Taipei 114, Taiwan (China)], E-mail: kuohsing91@yahoo.com.tw

    2009-08-15

    Introduction: Parkinson's disease (PD) affects both dopaminergic and serotonergic systems. In this study, we simultaneously evaluated dopamine and serotonin transporters in primates using dual-isotope single-photon emission computed tomography (SPECT) imaging and compared the results with traditional single-isotope imaging. Methods: Four healthy and one 6-OHDA-induced PD monkeys were used for this study. SPECT was performed over 4 h after individual or simultaneous injection of [{sup 99m}Tc]TRODAT-1 (a dopamine transporter imaging agent) and [{sup 123}I]ADAM (a serotonin transporter imaging agent). Results: The results showed that the image quality and uptake ratios in different brain regions were comparable between single- and dual-isotope studies. The striatal [{sup 99m}Tc]TRODAT-1 uptake in the PD monkey was markedly lower than that in normal monkeys. The uptake of [{sup 123}I]ADAM in the midbrain of the PD monkey was comparable to that in the normal monkeys, but there were decreased uptakes in the thalamus and striatum of the PD monkey. Conclusions: Our results suggest that dual-isotope SPECT using [{sup 99m}Tc]TRODAT-1 and [{sup 123}I]ADAM can simultaneously evaluate changes in dopaminergic and serotonergic systems in a PD model.

  12. Intellectual function and radiological images in patients with amyotrophic lateral sclerosis. Special reference to single photon emission computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Hiroo; Kanda, Mikio; Fukui, Toshiya; Sugita, Koujiro [Showa Univ., Tokyo (Japan). School of Medicine

    1994-10-01

    To clarify cognitive decline in amyotrophic lateral sclerosis (ALS), we compared cognitive and motor signs with neuroradiological features, with special reference to single photon emission computed tomography (SPECT), in 23 patients with ALS. Of these 23 patients, five demented patients (ALS-D) showed a decrease in voluntary speech output, abnormal behavior or character change. SPECT images in these patients were specifically characterized by marked uptake reduction in the frontal lobes. ALS patients with normal mentality (ALS-N) showed either a normal pattern or non-specific patchy uptake reduction on SPECT, but never showed the diffuse frontal uptake reduction that was observed in ALS-D patients. None of the ALS-N patients showed cognitive decline or frontal uptake reduction during the follow-up period of up to 29 months. There was no relation in either ALS-D or ALS-N patients between the degree of tracer uptake reduction and clinical features of ALS including severity and duration of illness. Clinical and neuroradiological features in ALS-D patients were compatible with those of `frontal lobe dementia`. ALS-D patients may compose a distinct group because cognitive decline is unlikely to occur in ALS-N patients with a long clinical course. ALS-D patients may be differentiated from other non-demented ALS patients in the early clinical course by the characteristic diffuse frontal uptake reduction on SPECT. (author).

  13. Alterations of Regional Cerebral Blood Flow in Tinnitus Patients as Assessed Using Single-Photon Emission Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Takashi Ueyama

    Full Text Available Tinnitus is the perception of phantom sound without an external auditory stimulus. Using neuroimaging techniques, such as positron emission tomography, electroencephalography, magnetoencephalography, and functional magnetic resonance imaging (fMRI, many studies have demonstrated that abnormal functions of the central nervous system are closely associated with tinnitus. In our previous research, we reported using resting-state fMRI that several brain regions, including the rectus gyrus, cingulate gyrus, thalamus, hippocampus, caudate, inferior temporal gyrus, cerebellar hemisphere, and medial superior frontal gyrus, were associated with tinnitus distress and loudness. To reconfirm these results and probe target regions for repetitive transcranial magnetic stimulation (rTMS, we investigated the regional cerebral blood flow (rCBF between younger tinnitus patients (<60 years old and the age-matched controls using single-photon emission computed tomography and easy Z-score imaging system. Compared with that of controls, the rCBF of tinnitus patients was significantly lower in the bilateral medial superior frontal gyri, left middle occipital gyrus and significantly higher in the bilateral cerebellar hemispheres and vermis, bilateral middle temporal gyri, right fusiform gyrus. No clear differences were observed between tinnitus patients with normal and impaired hearing. Regardless of the assessment modality, similar brain regions were identified as characteristic in tinnitus patients. These regions are potentially involved in the pathophysiology of chronic subjective tinnitus.

  14. Evaluation of myocardial infarction size with three-dimensional speckle tracking echocardiography: a comparison with single photon emission computed tomography.

    Science.gov (United States)

    Wang, Qiushuang; Zhang, Chunhong; Huang, Dangsheng; Zhang, Liwei; Yang, Feifei; An, Xiuzhi; Ouyang, Qiaohong; Zhang, Meiqing; Wang, Shuhua; Guo, Jiarui; Ji, Dongdong

    2015-12-01

    To assess whether global and regional myocardial strains from three-dimensional speckle tracking echocardiography (3D-STE) correlate with myocardial infarction size (MIS) detected by single photon emission computed tomography (SPECT). Fifty-seven patients with a history of ST-segment elevation myocardial infarction (MI) within 3-6 months were enrolled, alongside 24 healthy volunteers. Left ventricular (LV) global area strain, global longitudinal strain (GLS), global radial strain, global circumferential strain, left ventricular ejection fraction (LVEF) and wall motion score index (WMSI) were measured and compared with the corresponding SPECT-detected MISs. Patients were sub-grouped into massive MIS group (MIS ≥ 12%) and small MIS group (MIS Myocardial strains of all the LV segments were compared with the corresponding MIS. Global myocardial strain parameters, LVEF and WMSI of the patients were significantly different from the control group (all P myocardial strain parameters were found between the massive and small MIS groups (all P myocardial strain parameters were observed between segments with and without transmural MIs (P myocardial strain parameters evaluated LV global MIS, 3D GLS had the highest diagnostic value. It also preliminarily gauged the degree of ischemia and necrosis of regional myocardial segments.

  15. Evaluation of dilated cardiomyopathy by /sup 201/Tl myocardial single photon emission computed tomography. Morphological and quantitative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Futagami, Yasuo; Makino, Katsutoshi; Ichikawa, Takehiko

    1984-08-01

    To estimate dilated cardiomyopathy (DCM)morphologically and quantitatively, /sup 201/Tl myocardial single photon emission computed tomography (SPECT) was performed in 14 DCM and 5 normal cases. Using a rotating dual-gamma camera system, resting SPECT data were collected for 6 minutes. Quantitative analysis of clinical cases was based on phantom studies. Marked spherical left ventricular (LV) dilatation (14/14), localized-diffuse low uptake or defect (12/14), and right ventricular visualization (6/14) were characteristic features in DCM. Differentiation of DCM from ischemic heart disease by SPECT was possible through the feature indicating disproportionately large LV cavity to defect size or degree. Quantitative analysis When DCM was compared with normal control (n-5), following 3 features were impressive: DCM was significantly higher in LV myocardial /sup 201/Tl uptake ratio and LV volume than normal control; DCM was significantly lower in LV myocardial /sup 201/Tl uptake ratio of unit volume (1 ml) than normal control; DCM was significantly lower in mean myocardial count/mean lung count.ratio than normal control.

  16. Dynamic single photon emission computed tomography using N-isopropyl-p-(/sup 123/I)iodoamphetamine for cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Takashi; Kinoshita, Kazuo; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi

    1988-03-01

    Continuous sequential single photon emission computed tomography (dynamic SPECT) with N-isopropyl-p-(/sup 123/I)iodoamphetamine (IMP) was perfomed in 17 patients with cerebrovascular diseases (three with transient ischemic attack, four with cerebral infarction, two with ruptured aneurysms, two with arteriovenous malformations (AVM), one with an unruptured giant aneurysm, and five with moyamoya disease). Dynamic SPECT scans were obtained with a circular-detector array emission CT instrument at a fixed level parallel to the orbitomeatal plane. The scans were taken over a 20-minute period, at 2-minute intervals, immediately after intravenous injection of IMP. Time courses of activity ratio of the affectednon-affected areas were calculated. Accumulation of IMP in ischemic areas was consistently suppressed to approximately 70 to 80% that in the non-affected areas. IMP accumulation in infarcted regions was less than 40 to 50% that in non-affected areas. In the regions of AVM and giant aneurysm, accumulation of IMP was rapid and relatively high, but its removal was prompt. Dynamic IMP SPECT appears useful in the assessment of cerebral perfusion and may have numerous applications in neurosurgery.

  17. Abnormal response to mental stress in patients with Takotsubo cardiomyopathy detected by gated single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sciagra, Roberto; Genovese, Sabrina; Pupi, Alberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy); Parodi, Guido; Bellandi, Benedetta; Antoniucci, David [Careggi Hospital, Division of Cardiology, Florence (Italy); Del Pace, Stefano; Zampini, Linda; Gensini, Gian Franco [Careggi Hospital, Department of Heart and Vessels, Unit of General Cardiology, Florence (Italy)

    2010-04-15

    Persistent abnormalities are usually not detected in patients with Takotsubo cardiomyopathy (TTC). Since sympathetically mediated myocardial damage has been proposed as a causative mechanism of TTC, we explored whether mental stress could evoke abnormalities in these patients. One month after an acute event, 22 patients fulfilling all TTC diagnostic criteria and 11 controls underwent resting and mental stress gated single photon emission computed tomography (SPECT). Perfusion, wall motion, transient ischaemic dilation (TID) and left ventricular (LV) ejection fraction (EF) were evaluated. None of the controls showed stress-induced abnormalities. Mental stress evoked regional changes (perfusion defects and/or wall motion abnormality) in 16 TTC subjects and global abnormalities (LVEF fall >5% and/or TID >1.10) in 13; 3 had a completely negative response. TID, delta LVEF and delta wall motion score were significantly different in TTC vs control patients: 1.08 {+-} 0.20 vs 0.95 {+-} 0.11 (p < 0.05), -1.7 {+-} 6% vs 4 {+-} 5% (p < 0.02) and 2.5 (0, 4.25) vs 0 (0, 0) (p < 0.002), respectively. Mental stress may evoke regional and/or global abnormalities in most TTC patients. The abnormal response to mental stress supports the role of sympathetic stimulation in TTC. Mental stress could thus be helpful for TTC evaluation. (orig.)

  18. CO2BOLD assessment of moyamoya syndrome: Validation with single photon emission computed tomography and positron emission tomography imaging

    Science.gov (United States)

    Pellaton, Alain; Bijlenga, Philippe; Bouchez, Laurie; Cuvinciuc, Victor; Barnaure, Isabelle; Garibotto, Valentina; Lövblad, Karl-Olof; Haller, Sven

    2016-01-01

    AIM To compare the assessment of cerebrovascular reserve (CVR) using CO2BOLD magnetic resonance imaging (MRI) vs positron emission tomography (PET) and single photon emission computed tomography (SPECT) as reference standard. METHODS Ten consecutive patients (8 women, mean age of 41 ± 26 years) with moyamoya syndrome underwent 14 pre-surgical evaluations for external-internal carotid artery bypass surgery. CVR was assessed using CO2BOLD and PET (4)/SPECT (11) with a maximum interval of 36 d, and evaluated by two experienced neuroradiologists. RESULTS The inter-rater agreement was 0.81 for SPECT (excellent), 0.43 for PET (fair) and 0.7 for CO2BOLD (good). In 9/14 cases, there was a correspondence between CO2BOLD and PET/SPECT. In 4/14 cases, CVR was over-estimated in CO2BOLD, while in 1/14 case, CVR was underestimated in CO2BOLD. The sensitivity of CO2BOLD was 86% and a specificity of 43%. CONCLUSION CO2BOLD can be used for pre-surgical assessment of CVR in patients with moyamoya syndrome and combines the advantages of absent irradiation, high availability of MRI and assessment of brain parenchyma, cerebral vessels and surrogate CVR in one stop. PMID:27928470

  19. Superconducting Single Photon Detectors

    NARCIS (Netherlands)

    Dorenbos, S.N.

    2011-01-01

    This thesis is about the development of a detector for single photons, particles of light. New techniques are being developed that require high performance single photon detection, such as quantum cryptography, single molecule detection, optical radar, ballistic imaging, circuit testing and fluoresc

  20. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  1. In vivo imaging of brain dopaminergic neurotransmission system in small animals with high-resolution single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Saji, Hideo; Kawashima, Hidekazu; Ogawa, Mikako; Kitamura, Youji; Mukai, Takahiro [Kyoto University, Graduate School of Pharmaceutical Sciences, Kyoto (Japan); Iida, Yasuhiko; Shimazu, Seiichiro; Yoneda, Fumiro [Fujimoto Pharmaceutical Corporation, Matsubara, Osaka (Japan)

    2003-01-01

    High-resolution single photon emission computed tomography (SPECT) provides a unique capability to image the biodistribution of radiolabeled molecules in small laboratory animals. Thus, we applied the high-resolution SPECT to in vivo imaging of the brain dopaminergic neurotransmission system in common marmosets using two radiolabeled ligands, [{sup 123}I]2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane ({beta}-CIT) as a dopamine transporter(DAT) ligand and [{sup 123}I]iodobenzamide (IBZM) as a dopamine D{sub 2} receptor (D{sub 2}R) ligand. Specific images of the striatum, a region with a high density of dopaminergic synapses, were obtained at 240 min and 60 min after injection of [{sup 123}I]{beta}-CIT and [{sup 123}I]IBZM, respectively. Furthermore, a significantly low accumulation of [{sup 123}I]{beta}-CIT in the striatum was observed in MPTP-treated animals compared with results for a control group, and a similar accumulation in the control group was observed with the pretreatment of deprenyl in the MPTP-treated animals. However, the striatal accumulation of [{sup 123}I]IBZM showed no changes among the control, MPTP-treated, and deprenyl-MPTP-treated groups. These SPECT imaging results agreed well with those of DA concentration and motor behavior. Since MPTP destroys nigrostriatal dopamine nerves and produces irreversible neurodegeneration associated with Parkinsonian syndrome, SPECDT imaging data in this study demonstrated that deprenyl shows its neuroprotective effect on Parkinsonism by protecting against the destruction of presynaptic dopamine neutrons. (author)

  2. The Prognostic Role of Magnetic Resonance Imaging and Single-Photon Emission Computed Tomography in Viral Encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Misra, U.K.; Kalita, J.; Srivastav, A.; Pradhan, P.K. (Depts. of Neurology and Nuclear Medicine, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India))

    2008-09-15

    Background: There is a paucity of studies evaluating the prognostic role of magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) changes in viral encephalitis. Purpose: To study MRI and SPECT changes in patients with viral encephalitis, and to correlate these changes with clinical findings and outcome. Material and Methods: During 1997-2006, 31 encephalitis patients (aged 2-60 years; nine females, 22 males) underwent both MRI and SPECT studies. Their demographic and clinical data and 6-month outcome were recorded. For the diagnosis of encephalitis, polymerase chain reaction (PCR) and IgM enzyme-linked immunosorbent assay (ELISA) were carried out. Cranial MRI was done on a 1.5 T scanner, and 99mTc ethylene cysteine dimer (ECD) SPECT using a gamma camera. Outcome was defined at 6 months as complete, partial, or poor recovery. Results: 19 patients had Japanese encephalitis (JE), one had herpes simplex encephalitis (HSE), and 11 had nonspecific encephalitis. Movement disorders were present in 21, parkinsonian features in 19, and dystonia in 16 patients. MRI was abnormal in 20 patients, and revealed thalamic involvement in 17, basal ganglia in eight, brainstem in 11, and cortical in two. SPECT revealed hypoperfusion in 22 patients, which was cortical in 11, thalamic in 10, basal ganglia in six, and midbrain in one. Cortical involvement was more frequently found by SPECT and brainstem involvement by MRI. Outcome of encephalitis did not differ in the different groups of encephalitis and MRI changes. Conclusion: MRI and SPECT show a spectrum of findings in encephalitis, but these do not correlate with 6-month outcome

  3. Brain areas involved in acupuncture needling sensation of de qi: a single-photon emission computed tomography (SPECT) study.

    Science.gov (United States)

    Chen, Jia-Rong; Li, Gan-Long; Zhang, Gui-Feng; Huang, Yong; Wang, Shu-Xia; Lu, Na

    2012-12-01

    De qi is a sensory response elicited by acupuncture stimulation. According to traditional Chinese medicine (TCM), de qi is essential for clinical efficacy. However, the understanding of the neurobiological basis of de qi is still limited. To investigate the relationship between brain activation and de qi by taking a single-photon emission computed tomography (SPECT) scan while applying acupuncture at TE5. A total of 24 volunteers were randomly divided into 4 groups, and received verum or sham acupuncture at true acupuncture point TE5 or a nearby sham point according to grouping. All subjects then received a (99m)Tc-ethylcysteinate dimer (ECD) SPECT scan. All six subjects in the verum acupuncture at true acupuncture point group experienced de qi sensation; in contrast, all six subjects in the sham acupuncture at the sham point group responded with nothing other than non-sensation. Compared to the scan results from subjects who experienced non-sensation, SPECT scans from subjects with de qi sensation demonstrated significant activated points mainly located in brodmann areas 6, 8, 19, 21, 28, 33, 35, 37, 47, the parahippocampal gyrus, lentiform nucleus, claustrum and red nucleus; deactivated points were seen in brodmann areas 9 and 25. Verum acupuncture at true acupuncture points is more likely to elicit de qi sensation. De qi sensations mainly resulted in brain area activations, but not deactivations. These brain areas are related to the curative effect of Te5. The acupuncture needle sensations of de qi and sharp pain are associated with different patterns of activations and deactivations in the brain.

  4. Measurement of acute Q-wave myocardial infarct size with single photon emission computed tomography imaging of indium-111 antimyosin

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, M.L.; Seldin, D.W.; Wall, R.M.; Johnson, L.L.

    1989-04-01

    Myocardial infarct size was measured by single photon emission computed tomography (SPECT) following injection of indium-111 antimyosin in 27 patients (18 male and 9 female; mean age 57.4 +/- 10.5 years, range 37 to 75) who had acute transmural myocardial infarction (MI). These 27 patients represent 27 of 35 (77%) consecutive patients with acute Q-wave infarctions who were injected with indium-111 antimyosin. In the remaining 8 patients either tracer uptake was too faint or the scans were technically inadequate to permit infarct sizing from SPECT reconstructions. In the 27 patients studied, infarct location by electrocardiogram was anterior in 15 and inferoposterior in 12. Nine patients had a history of prior infarction. Each patient received 2 mCi of indium-111 antimyosin followed by SPECT imaging 48 hours later. Infarct mass was determined from coronal slices using a threshold value obtained from a human torso/cardiac phantom. Infarct size ranged from 11 to 87 g mean (48.5 +/- 24). Anterior infarcts were significantly (p less than 0.01) larger (60 +/- 20 g) than inferoposterior infarcts (34 +/- 21 g). For patients without prior MI, there were significant inverse correlations between infarct size and ejection fraction (r = 0.71, p less than 0.01) and wall motion score (r = 0.58, p less than 0.01) obtained from predischarge gated blood pool scans. Peak creatine kinase-MB correlated significantly with infarct size for patients without either reperfusion or right ventricular infarction (r = 0.66). Seven patients without prior infarcts had additional simultaneous indium-111/thallium-201 SPECT studies using dual energy windows.

  5. Beneficial effect of coronary artery bypass grafting as assessed by quantitative gated single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hida, Satoshi; Chikamori, Taishiro; Hirayama, Tetsuzo; Usui, Yasuhiro; Yanagisawa, Hidefumi; Morishima, Takayuki; Ishimaru, Shin; Yamashina, Akira [Tokyo Medical Coll. (Japan)

    2003-06-01

    The development of quantitative gated single-photon emission computed tomography (SPECT) has enabled the assessment of left ventricular perfusion, function and wall thickness in a single examination. Accordingly, the present study used gated SPECT to assess the benefit of coronary artery bypass grafting (CABG) in patients with coronary artery disease; 47 of those patients were evaluated before and 5 months after CABG. As a result of coronary revascularization, a significant improvement was observed in global ejection fraction (50{+-}12{yields}53{+-}11%; p<0.05). In 107 revascularized territories, the average regional reversible defect score (0.8{+-}0.5{yields}0.2{+-}0.3; p<0.0001), average regional perfusion score at rest (0.6{+-}0.6{yields}0.3{+-}0.4; p<0.0001), average regional wall motion score (0.9{+-}0.7{yields}0.7{+-}0.5; p<0.05), and end-diastolic wall thickness (8.1{+-}1.3{yields}8.6{+-}1.5 mm; p<0.0005) all improved significantly. Even in 34 non-revascularized territories, the average regional reversible defect score (0.5{+-}0.7{yields}0.2{+-}0.5; p<0.03), average regional wall motion score (0.8{+-}1.1{yields}0.5{+-}1.0; p<0.03) and end-diastolic wall thickness (8.0{+-}1.4{yields}9.1{+-}2.0 mm; p<0.03) all improved significantly. These results indicate that improvement in myocardial ischemia, hibernation and left ventricular function with CABG can be assessed in detail with gated SPECT. (author)

  6. Single photon quantum cryptography

    CERN Document Server

    Beveratos, A; Gacoin, T; Villing, A; Poizat, J P; Grangier, P; Beveratos, Alexios; Brouri, Rosa; Gacoin, Thierry; Villing, Andre; Poizat, Jean-Philippe; Grangier, Philippe

    2002-01-01

    We report the full implementation of a quantum cryptography protocol using a stream of single photon pulses generated by a stable and efficient source operating at room temperature. The single photon pulses are emitted on demand by a single nitrogen-vacancy (NV) color center in a diamond nanocrystal. The quantum bit error rate is less that 4.6% and the secure bit rate is 9500 bits/s. The overall performances of our system reaches a domain where single photons have a measurable advantage over an equivalent system based on attenuated light pulses.

  7. Single photon quantum cryptography.

    Science.gov (United States)

    Beveratos, Alexios; Brouri, Rosa; Gacoin, Thierry; Villing, André; Poizat, Jean-Philippe; Grangier, Philippe

    2002-10-28

    We report the full implementation of a quantum cryptography protocol using a stream of single photon pulses generated by a stable and efficient source operating at room temperature. The single photon pulses are emitted on demand by a single nitrogen-vacancy color center in a diamond nanocrystal. The quantum bit error rate is less that 4.6% and the secure bit rate is 7700 bits/s. The overall performances of our system reaches a domain where single photons have a measurable advantage over an equivalent system based on attenuated light pulses.

  8. Hologram of a single photon

    Science.gov (United States)

    Chrapkiewicz, Radosław; Jachura, Michał; Banaszek, Konrad; Wasilewski, Wojciech

    2016-09-01

    The spatial structure of single photons is becoming an extensively explored resource to facilitate free-space quantum communication and quantum computation as well as for benchmarking the limits of quantum entanglement generation with orbital angular momentum modes or reduction of the photon free-space propagation speed. Although accurate tailoring of the spatial structure of photons is now routinely performed using methods employed for shaping classical optical beams, the reciprocal problem of retrieving the spatial phase-amplitude structure of an unknown single photon cannot be solved using complementary classical holography techniques that are known for excellent interferometric precision. Here, we introduce a method to record a hologram of a single photon that is probed by another reference photon, on the basis of a different concept of the quantum interference between two-photon probability amplitudes. As for classical holograms, the hologram of a single photon encodes the full information about the photon's ‘shape’ (that is, its quantum wavefunction) whose local amplitude and phase are retrieved in the demonstrated experiment.

  9. QUANTUM CRYPTOGRAPHY: Single Photons.

    Science.gov (United States)

    Benjamin, S

    2000-12-22

    Quantum cryptography offers the potential of totally secure transfer of information, but as Benjamin discusses in this Perspective, its practical implementation hinges on being able to generate single photons (rather than two or more) at a time. Michler et al. show how this condition can be met in a quantum dot microdisk structure. Single molecules were also recently shown to allow controlled single-photon emission.

  10. Single photon emission computer tomography of dopamine transporters in monkeys and humans with 99mTc-TRODAT-1

    Institute of Scientific and Technical Information of China (English)

    胡平; 陈玲; 张海琴; 黎锦如; 梁宏

    2004-01-01

    Background The diagnosis of Parkinson's disease is presently based on non-specific symptoms. However, radionuclide dopamine transporters imaging can provide specific diagnostic tool for Parkinson's disease. This study was designed to investigate the effects of imaging of dopamine transporters with 99mTc-TRODAT-1 in early diagnosis or differential diagnosis of Parkinson's disease.Methods Nine normal monkeys were used to establish N-methyl-4-phenyl-1, 2, 3, 6-tetra-hydropyridine (MPTP) hemi-Parkinsonian animal models, and they were subjected to imaging. Twenty-nine patients with Parkinson's disease, 12 age-matched healthy volunteers, and 18 age-matched patients with Parkinson's syndrome were investigated. Single photon emission computer tomography (SPECT) was performed 3 hours after intravenous injection of 740 MBq 99mTc-TRODAT-1. Striatum specific uptake of 99mTc-TRODAT-1 was calculated according to the ratio of striatum (ST) to cerebellum (CB)in dopamine transporters uptake.Results In normal monkeys, bilateral ratio of ST/CB was 2.34±0.41. After the injection of MPTP, uptake rate of 99mTc-TRODAT-1 at damaged region was much lower than that at the contralateral region, resulting in a significant difference in the ratio of ST/CB (right: ST/CB=1.73±0.35; left: ST/CB=1.90±0.30), especially in hemi-Parkinsonian model monkeys (right: ST/CB=1.29±0.17; left: ST/CB=1.80±0.33). The ratios of ST/CB were 1.57±0.17 and 1.61±0.14 for the right and left respectively in the healthy volunteers, 1.04±0.29 and 1.06±0.30 in the age-matched patients with Parkinson's disease, and 1.56±0.17 and 1.59±0.18 in the age-matched patients with Parkinson's disease syndrome. A significant difference was noted between group of Parkinson's disease, normal controls and Parkinson's disease syndrome. Conclusion The results suggest that 99mTc-TRODAT-1 dopamine transporters SPECT has clinical application value in early diagnosis or differential diagnosis of Parkinson's disease.

  11. Fundamental studies of myocardial defect size quantification using positron emission tomography and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Tatsuya [Kanazawa Univ. (Japan). School of Medicine

    2001-04-01

    In Flurine-18 fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography (PET) acquisition, a transmission scan is usually performed before the PET tracer injection (cold transmission method), followed by a subsequent emission scan. However, this procedure is time consuming. An alternative approach, in which the transmission scan is performed after the emission scan (hot transmission method), would significantly reduce the time required for data acquisition. Recently, three-dimensional PET acquisition (3D PET) has become available. The counting sensitivity is much higher in 3D PET than in conventional two-dimensional PET (2D PET), resulting in a shorter acquisition time and reduced radiation exposure for the patient. On the other hand, {sup 18}F-FDG imaging using single photon emission computed tomography (SPECT), a more widely available method than PET, has emerged as an alternative to PET. The purpose of this study was to investigate the accuracy of measurement of myocardial defect sizes by these new techniques, using a chest phantom. Acquisitions were performed using an elliptical cylinder chest phantom. Plastic inserts, ranging in size from 2-60% of the myocardium (n=12), were used as simulated models of transmural myocardial infarction. Fluorine-18 was given into each part of the phantom. PET imaging with cold and hot transmission methods, 3D PET, and SPECT imaging were performed with different acquisition times and different radioisotope concentrations. All PET and SPECT data were analyzed using a semiquantitative polar map approach. Defect sizes were quantified using various cutoff thresholds, and were expressed as a percentage of the left ventricular myocardium. The PET and SPECT measurements were compared with the true defect sizes. Among the various cutoff levels tested, the mean absolute difference between the measured and true defect sizes was minimal at 50% of peak activity for both PET and SPECT. The PET measurements with the hot transmission

  12. Potential advantage of preoperative three-dimensional mapping of sentinel nodes in breast cancer by a hybrid single photon emission CT (SPECT)/CT system

    OpenAIRE

    Ibusuki, Mutsuko; Yamamoto, Yutaka; Kawasoe, Teru; Shiraishi, Shinya; Tomiguchi, Seiji; Yamashita, Yasuyuki; Honda, Yumi; Iyama, Kenichi; Iwase, Hirotaka; イブスキ, ムツコ; ヤマモト, ユタカ; カワソエ, テル; シライシ, シンヤ; トミグチ, セイジ; ヤマシタ, ヤスユキ

    2010-01-01

    Objective: This study aims to assess the role of three dimensional single-photon emissioncomputed tomography (3D-SPECT/CT) in sentinel node (SN) identification, and toanalyze the impact of such information on estimating metastases to SNs.Background: Nodal status is a key factor for breast cancer. SN biopsy has beenestablished as the alternative to routine axillary dissection these days. We investigatedboth the anatomical location of SNs demonstrated by our 3D-SPECT/CT system and thecorrelatio...

  13. Importance of 123I-metaiodobenzylguanidine scintigraphy/single photon emission computed tomography for diagnosis and differential diagnostics of Parkinson syndromes.

    Science.gov (United States)

    Jost, Wolfgang H; Del Tredici, Kelly; Landvogt, Christian; Braune, Stefan

    2010-01-01

    The goal of Parkinson syndrome diagnostics is twofold: early diagnosis on the one hand, and accurate differentiation among idiopathic and atypical Parkinson syndromes on the other. (123)I-metaiodobenzylguanidine scintigraphy is the only method that can distinguish with a high degree of sensitivity and specificity between atypical Parkinson syndromes and Parkinson's disease or dementia with Lewy bodies. Additional advantages are the method's widespread availability and radioactive exposure dose comparable to that for single photon emission computed tomography imaging with much lower costs. Only a single radiotracer study is necessary. (123)I-metaiodobenzylguanidine scintigraphy is an indispensable tool for purposes of differentiating among the various Parkinson syndromes.

  14. Association of Novelty Seeking Scores and Striatal Dopamine D2/D3 Receptor Availability of Healthy Volunteers: Single Photon Emission Computed Tomography With 123I-iodobenzamide

    Directory of Open Access Journals (Sweden)

    Hsiang Yu Huang

    2010-10-01

    Full Text Available It has been speculated that novelty seeking (NS behavior is related to the dopaminergic system. Fifty-two subjects completed the Tridimensional Personality Questionnaire and underwent single photon emission computed tomography with 123I-iodobenzamide. A marginally positive correlation was noted between NS and striatal dopamine D2/D3 receptor availability (r = 0.25, p =0.07. A positive association was noted between the NS scores and left striatal D2/D3 receptor availability (r= 0.29, p =0.04. The results suggest that a relationship might exist between NS score and dopaminergic activity.

  15. Degenerative dementia: nosological aspects and results of single photon emission computed tomography; Les demences degeneratives: aspects nosologiques et resultats de la tomographie d'emission monophotonique

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, B.; Habert, M.O. [Hopital Pitie-Salpetriere, 75 - Paris (France)

    1999-12-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  16. Hemimegalencephaly: A rare cause of hemihypoperfusion on 99m technetium-ethyl cysteinate dimer brain perfusion single-photon emission computed tomography.

    Science.gov (United States)

    Damle, Nishikant A; Singhal, Abhinav; Mukherjee, Anirban; Sahoo, Manas Kumar; Tripathi, Madhavi; Bal, Chandrasekhar

    2013-04-01

    Hemimegalencephaly is a rare congenital neuronal migration disorder that can presents with the equally rare finding of hemihypoperfusion on brain perfusion single-photon emission computed tomography (SPECT). It is an extremely rare cause of intractable epilepsy. Technetium-99m ethyl cysteinate dimer (ECD) brain perfusion SPECT is useful in excluding other foci of hypoperfusion in the contralateral since hemispherectomy has been suggested to be the treatment of choice. Furthermore, hemimegalencephaly may present with hyper as well as hypoperfusion on ECD SPECT. We present the case of an 11-year-old male child with intractable seizures who showed hemihypoperfusion in the hemimegalecephalic hemisphere.

  17. Simultaneous Computation of Two Independent Tasks Using Reservoir Computing Based on a Single Photonic Nonlinear Node With Optical Feedback.

    Science.gov (United States)

    Nguimdo, Romain Modeste; Verschaffelt, Guy; Danckaert, Jan; Van der Sande, Guy

    2015-12-01

    In this brief, we numerically demonstrate a photonic delay-based reservoir computing system, which processes, in parallel, two independent computational tasks even when the two tasks have unrelated input streams. Our approach is based on a single-longitudinal mode semiconductor ring laser (SRL) with optical feedback. The SRL emits in two directional optical modes. Each directional mode processes one individual task to mitigate possible crosstalk. We illustrate the feasibility of our scheme by analyzing the performance on two benchmark tasks: 1) chaotic time series prediction and 2) nonlinear channel equalization. We identify some feedback configurations for which the results for simultaneous prediction/classification indicate a good performance, but with slight degradation (as compared with the performance obtained for single task processing) due to nonlinear and linear interactions between the two directional modes of the laser. In these configurations, the system performs well on both tasks for a broad range of the parameters.

  18. Potential advantage of preoperative three-dimensional mapping of sentinel nodes in breast cancer by a hybrid single photon emission CT (SPECT)/CT system.

    Science.gov (United States)

    Ibusuki, Mutsuko; Yamamoto, Yutaka; Kawasoe, Teru; Shiraishi, Shinya; Tomiguchi, Seiji; Yamashita, Yasuyuki; Honda, Yumi; Iyama, Kenichi; Iwase, Hirotaka

    2010-06-01

    This study aims to assess the role of three-dimensional single-photon emission computed tomography (3D-SPECT/CT) in sentinel node (SN) identification, and to analyze the impact of such information on estimating metastases to SNs. Nodal status is a key factor for breast cancer. SN biopsy has been established as the alternative to routine axillary dissection these days. We investigated both the anatomical location of SNs demonstrated by our 3D-SPECT/CT system and the correlation to SN positivity. Two hundred and twenty-three clinically node-negative patients underwent SN biopsy. All of the axillary structures, including SNs, were visualized by a SPECT/CT combined system after subcutaneous injection of (99m)Tc-phytate. By plotting the visualized SNs, the most frequent SN location 'Pedestal area (PA)' was designated. SPECT/CT detected (99m)Tc uptake in 217 cases (97.3%). 3D-SPECT/CT images visualized the accurate location of SNs in each case. In patients whose SNs were histopathologically negative (SN-), 228 (98.3%) SNs were found in the PA, and 4 (1.7%) were in other zones. In those with histopathologically positive SNs (SN+), 65 (78.3%) SNs were in the PA and 18 (21.7%) were outside it. The difference in SN distribution (i.e., in or out of the PA) between SN+ and SN- patients was statistically significant (pSNs in patients with breast cancer. Atypical distribution of SNs out of the PA may suggest SN positivity, reflecting failure of the lymphatic drainage systems.

  19. Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

    Science.gov (United States)

    Rana, Nivedita; Rawat, Dinesh; Parmar, Madan; Dhawan, Devinder Kumar; Bhati, Ashok Kumar; Mittal, Bhagwant Rai

    2015-01-01

    This study was undertaken to evaluate the effect of external metal filters on the image quality of computed tomography (CT) and single photon emission computed tomography (SPECT)/CT images. Images of Jaszack phantom filled with water and containing iodine contrast filled syringes were acquired using CT (120 kV, 2.5 mA) component of SPECT/CT system, ensuring fixation of filter on X-ray collimator. Different thickness of filters of Al and Cu (1 mm, 2 mm, 3 mm, and 4 mm) and filter combinations Cu 1 mm, Cu 2 mm, Cu 3 mm each in combination with Al (1 mm, 2 mm, 3 mm, and 4 mm), respectively, were used. All image sets were visually analyzed for streak artifacts and contrast to noise ratio (CNR) was derived. Similar acquisition was done using Philips CT quality control (QC) phantom and CNR were calculated for its lexan, perspex, and teflon inserts. Attenuation corrected SPECT/CT images of Jaszack phantom filled with 444-555 MBq (12-15 mCi) of (99m)Tc were obtained by applying attenuation correction map generated by hardened X-ray beam for different filter combination, on SPECT data. Uniformity, root mean square (rms) and contrast were calculated in all image sets. Less streak artifacts at iodine water interface were observed in images acquired using external filters as compared to those without a filter. CNR for syringes, spheres, and inserts of Philips CT QC phantom was almost similar to Al 2 mm, Al 3 mm, and without the use of filters. CNR decreased with increasing copper thickness and other filter combinations. Uniformity and rms were lower, and value of contrast was higher for SPECT/CT images when CT was acquired with Al 2 mm and 3 mm filter than for images acquired without a filter. The study suggests that for Infinia Hawkeye 4, SPECT/CT system, Al 2 mm, and 3 mm are the optimum filters for improving image quality of SPECT/CT images of Jaszack or Philips CT QC phantom keeping other parameters of CT constant.

  20. Head sinuses, melon, and jaws of bottlenose dolphins, Tursiops truncatus, observed with computed tomography structural and single photon emission computed tomography functional imaging

    Science.gov (United States)

    Ridgway, Sam; Houser, Dorian; Finneran, James J.; Carder, Don; van Bonn, William; Smith, Cynthia; Hoh, Carl; Corbeil, Jacqueline; Mattrey, Robert

    2003-04-01

    The head sinuses, melon, and lower jaws of dolphins have been studied extensively with various methods including radiography, chemical analysis, and imaging of dead specimens. Here we report the first structural and functional imaging of live dolphins. Two animals were imaged, one male and one female. Computed tomography (CT) revealed extensive air cavities posterior and medial to the ear as well as between the ear and sound-producing nasal structures. Single photon emission computed tomography (SPECT) employing 50 mCi of the intravenously injected ligand technetium [Tc-99m] biscisate (Neurolite) revealed extensive and uptake in the core of the melon as well as near the pan bone area of the lower jaw. Count density on SPECT images was four times greater in melon as in the surrounding tissue and blubber layer suggesting that the melon is an active rather than a passive tissue. Since the dolphin temporal bone is not attached to the skull except by fibrous suspensions, the air cavities medial and posterior to the ear as well as the abutment of the temporal bone, to the acoustic fat bodies of each lower jaw, should be considered in modeling the mechanism of sound transmission from the environment to the dolphin ear.

  1. An incidentally found inflamed uterine myoma Causing low abdominal pain, using TC-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zandieh, Shahin; Schuetz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg [Hanusch-Hospital, Teaching Hospital of Medical University of Vienna, Vienna (Australia)

    2013-10-15

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  2. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2016-06-15

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment.

  3. Novel application of quantitative single-photon emission computed-tomography/computed tomography to predict early response to methimazole in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Bang, Ji In; Kim, Ji Young; Moon, Jae Hoon [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University Medical Center, Seoul (Korea, Republic of); Lee, Won Woo [Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul (Korea, Republic of)

    2017-06-15

    Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of {sup 99m}Tc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). A novel parameter of thyroid uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients.

  4. The Incremental Prognostic Value of Cardiac Computed Tomography in Comparison with Single-Photon Emission Computed Tomography in Patients with Suspected Coronary Artery Disease.

    Science.gov (United States)

    Lee, Heesun; Yoon, Yeonyee E; Park, Jun-Bean; Kim, Hack-Lyoung; Park, Hyo Eun; Lee, Seung-Pyo; Kim, Hyung-Kwan; Choi, Su-Yeon; Kim, Yong-Jin; Cho, Goo-Yeong; Zo, Joo-Hee; Sohn, Dae-Won

    2016-01-01

    Coronary computed tomographic angiography (CCTA) facilitates comprehensive evaluation of coronary artery disease (CAD), including plaque characterization, and can provide additive diagnostic value to single-photon emission computed tomography (SPECT). However, data regarding the incremental prognostic value of CCTA to SPECT remain sparse. We evaluated the independent and incremental prognostic value of CCTA, as compared with clinical risk factors and SPECT. A total of 1,077 patients with suspected CAD who underwent both SPECT and cardiac CT between 2004 and 2012 were enrolled retrospectively. Presence of reversible or fixed perfusion defect (PD) and summed stress score were evaluated on SPECT. Presence, extent of coronary atherosclerosis and diameter stenosis (DS) were evaluated on CCTA. Plaque composition was categorized as non-calcified, mixed, or calcified according to the volume of calcified component (>130 Hounsfield Units). Patients were followed up for the occurrence of adverse cardiac events including cardiac death, non-fatal myocardial infarction, unstable angina, and late revascularization (>90 days after imaging studies). During follow-up (median 23 months), adverse cardiac events were observed in 71 patients (6.6%). When adjusted for clinical risk factors and SPECT findings, the presence of any coronary plaque, any plaque in ≥3 segments, coronary artery calcium score (CACS) ≥400, a plaque ≥50% DS, presence of non-calcified plaque (NCP) or mixed plaque (MP), and NCP/MP in ≥2 segments were independent predictors of adverse cardiac events; however, the presence of calcified plaque (CP) was not. Conventional CCTA findings, including CACS ≥400 and a plaque ≥50% DS, demonstrated incremental prognostic value over clinical risk factors and SPECT (χ² 54.19 to 101.03; p incremental prognostic value in relation to SPECT evaluation of myocardial ischemia. Specifically, segmentally-analyzed plaque composition with CCTA provides further risk

  5. Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Uetani, Teruyoshi; Kono, Tamami; Ogimoto, Akiyoshi [Ehime University Graduate School of Medicine, Department of Cardiology, Pulmonology, Hypertension and Nephrology, Toon, Ehime (Japan); Soma, Tsutomu [FUJIFILM RI Pharma Co., Ltd., QMS Group, Quality Assurance Department, Tokyo (Japan); Graduate School of Medicine, University of Tokyo, Department of Radiology, Tokyo (Japan); Murase, Kenya [Osaka University Graduate School of Medicine, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Osaka (Japan); Iwaki, Hirotaka [Ehime University Graduate School of Medicine, Center for Clinical Research Data and Biostatistics, Toon, Ehime (Japan)

    2016-11-15

    To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) or single-photon emission computed tomography (SPECT). Fifty-three patients who underwent stress dynamic CTP and either SPECT (n = 25) or CMR (n = 28) were retrospectively selected. Normal and abnormal perfused myocardium (ischemia/infarction) were assessed by SPECT/CMR using 16-segment model. Sensitivity and specificity of CT-MBF (mL/g/min) for detecting the ischemic/infarction and severe infarction were assessed. The abnormal perfused myocardium and severe infarction were seen in SPECT (n = 90 and n = 19 of 400 segments) and CMR (n = 223 and n = 36 of 448 segments). For detecting the abnormal perfused myocardium, sensitivity and specificity were 80 % (95 %CI, 71-90) and 86 % (95 %CI, 76-91) in SPECT (cut-off MBF, 1.23), and 82 % (95 %CI, 76-88) and 87 % (95 %CI, 80-92) in CMR (cut-off MBF, 1.25). For detecting severe infarction, sensitivity and specificity were 95 % (95 %CI, 52-100) and 72 % (95 %CI, 53-91) in SPECT (cut-off MBF, 0.92), and 78 % (95 %CI, 67-97) and 80 % (95 %CI, 58-86) in CMR (cut-off MBF, 0.98), respectively. Dynamic CTP has a potential to detect abnormal perfused myocardium and severe infarction assessed by SPECT/CMR using comparable cut-off MBF. (orig.)

  6. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi; Hayashi, Takuji; Mitsugi, Ohara [Aichi Medical Univ., Nagakute (Japan)

    1994-12-01

    As a basis for possible classification of schinzophrenic psychoses into schizophrenia and atypical psychosis, we studied the brain functional differences among 16 schizophrenic patients, 16 atypical psychosis patients and 16 healthy volunteers by single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I] iodoamphetamine. As a result, schizophrenics showed hypofrontality. On the other hand, atypical psychotics had no such hypofrontality but showed a reduced uptake rate in the right thalamic region. No influence of sex, duration of illness and medication was confirmed by the findings. The results suggest that schizophrenics might have some lesions in the frontal regions, whereas atypical psychotics might have no such lesions, but dysfunction in the right thalamic region. Consequently, the SPECT findings as least indicate possibly different etiologies for schizophrenia and atypical psychosis. (author).

  7. Acute effect of electroconvulsive therapy on brain perfusion assessed by Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, D.; Ivancevic, D. (Department of Nuclear Medicine, University Hospital Rebro, Zagreb (Yugoslavia)); Medved, V. (Psychiatric Clinic, University Hospital Rebro, Zagreb (Yugoslavia))

    1989-01-01

    Regional cerebral blood flow (rCBF) was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim and single photon emission computed tomography in 11 patients undergoing electroconvulsive therapy (ECT). The patients suffered from major depressive disorder (n=8) or schizoaffective disorders (n=3). rCBF was measured under general anesthesia 3 days prior to the ECT treatment and coinciding with the ECT stimualtion. ECT caused a redistribution of the tracers uptake. The uptake became more pronounced in frontal parts of the brain and in the basal ganglia than in posterior parts of the cortex, and the thalamus. This selective effect of ECT on rCBF may be related to catecholaminergic projections to anterior parts of the brain. (author).

  8. Phantom study to evaluate quantitative changes in myocardial radioisotope concentration for single photon emission computed tomography; Comparison between Tl-201 and Tc-99m

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Takashi; Kitabata, Yoshiki; Tanaka, Takeshi; Hasegawa, Mitsuo; Kato, Kazuzo (Cardiovascular Inst., Tokyo (Japan)); Okabe, Akifumi

    1990-01-01

    Quantitative changes in Tl-201 and Tc-99m in myocardial single photon emission computed tomography (SPECT) were evaluated using phantom studies. The absorption rate of gamma ray by the tissues surrounding the myocardium was less for Tc-99m (maximum, 61.2%) than Tl-201 (maximum, 70.8%). In studies on quantification of defects with various concentrations of the radioisotopes, Tc-99m was found superior to Tl-201. In comparing a focal defect in the anterior wall near the surface of the thorax (Defect A) with that in the posterior wall deep in the thorax (Defect B), Defect A had a better quantification than Defect B. Absorber, scattering, and background, however, precluded quantification, especially in Defect B. Although scatter subtraction may in part improve quantification, quantification seemed to be dependent on algorithm in image reconstruction, as well as spatial resolution of the equipment. (N.K.).

  9. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung [China Medical Coll., Taichung, Taiwan (China). Hospital; Wang, Jhi-Joung [Chi-Mei Medical Center, Tainan, Taiwan (China); Ho, Shung-Tai [National Defense Medical Center, Taipei, Taiwan (China). School of Medicine

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  10. Striatal dopamine release in reading and writing measured with [123I]iodobenzamide and single photon emission computed tomography in right handed human subjects.

    Science.gov (United States)

    Schommartz, B; Larisch, R; Vosberg, H; Müller-Gärtner, H M

    2000-09-29

    Competition between endogenous dopamine and a radioligand for postsynaptic dopamine D(2) receptor binding was examined in two groups of eight subjects each who had to read or write off a text, respectively, and in a control group. Single photon emission computed tomography (SPECT) and the ligand [(123)I]iodobenzamide (IBZM) were used for in vivo imaging. Subjects commenced reading or writing immediately before IBZM injection and continued for 30min thereafter. SPECT images were acquired 60min later. Striatum-to-parietal-cortex IBZM uptake ratios were lower in subjects who wrote off the text than in controls indicating competition of IBZM and dopamine. There was no difference between subjects who read the text and controls. Thus, dopamine release occurs as a consequence of the motoric activity involved in writing rather than of cognitive functions necessary for reading the text.

  11. Variable uptake feature of focal nodular hyperplasia in Tc-99m phytate hepatic scintigraphy/single-photon emission computed tomography-A parametric analysis.

    Science.gov (United States)

    Hsu, Yu-Ling; Chen, Yu-Wen; Lin, Chia-Yang; Lai, Yun-Chang; Chen, Shinn-Cherng; Lin, Zu-Yau

    2015-12-01

    Tc-99m phytate hepatic scintigraphy remains the standard method for evaluating the functional features of Kupffer cells. In this study, we demonstrate the variable uptake feature of focal nodular hyperplasia (FNH) in Tc-99m phytate scintigraphy. We reviewed all patients who underwent Tc-99m phytate hepatic scintigraphy between 2008 and 2012 in Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. Cases with FNH were diagnosed on the basis of pathology or at least one or more prior imaging with a periodic clinical follow-up. All patients received a standard protocol of dynamic flow study and planar and Tc-99m phytate single-photon emission computed tomography (E. CAM; Siemens). The correlation of variable nodular radioactivity with parameters such as tumor size and localization was analyzed. In total, 15 lesions of 14 patients in the clinic were diagnosed as FNH. The tumor size was approximately 2.9-7.4 cm (mean size 4.6 cm). Four lesions were larger than 5 cm. The major anatomic distribution was in the right hepatic lobe (10 lesions), particularly in the superior segments (7 lesions). Tc-99m phytate single-photon emission computed tomography imaging for determining the functional features of Kupffer cells included cool/cold (8 lesions), isoradioactive/warm (6 lesions), and hot (1 lesion) patterns of uptake. We did not observe any statistically significant correlation between variable nodular radioactivity and tumor size (p=0.68) or localization (p=0.04). Herein, we demonstrate the variable uptake feature of FNH in Tc-99m phytate scintigraphy. In small FNH tumors (< 5 cm), increased or equal uptake still provided specificity for the differential diagnosis of hepatic solid tumors.

  12. Single photons on demand

    Energy Technology Data Exchange (ETDEWEB)

    Grangier, P. [Institut d' Optique, Laboratoire Charles Fabry, Orsay (France)]. E-mail: philippe.grangier@iota.u-psud.fr; Abram, I. [Laboratoire de Photonique et Nanostructures, Route de Nozay, Marcoussis (France)]. E-mail: izo.abram@lpn.cnrs.fr

    2003-02-01

    Quantum cryptography and information processing are set to benefit from developments in novel light sources that can emit photons one by one. Quantum mechanics has gained a reputation for making counter-intuitive predictions. But we rarely get the chance to witness these effects directly because, being humans, we are simply too big. Take light, for example. The light sources that are familiar to us, such as those used in lighting and imaging or in CD and DVD players, are so huge that they emit billions and billions of photons. But what if there was a light source that emitted just one photon at a time? Over the past few years, new types of light source that are able to emit photons one by one have been emerging from laboratories around the world. Pulses of light composed of a single photon correspond to power flows in the femtowatt range - a million billion times less than that of a table lamp. The driving force behind the development of these single-photon sources is a range of novel applications that take advantage of the quantum nature of light. Quantum states of superposed and entangled photons could lead the way to guaranteed-secure communication, to information processing with unprecedented speed and efficiency, and to new schemes for quantum teleportation. (U.K.)

  13. Assessment of the relationship between stenosis severity and distribution of coronary artery stenoses on multislice computed tomographic angiography and myocardial ischemia detected by single photon emission computed tomography

    Science.gov (United States)

    Tamarappoo, Balaji K.; Gutstein, Ariel; Cheng, Victor Y.; Nakazato, Ryo; Gransar, Heidi; Dey, Damini; Thomson, Louise E. J.; Hayes, Sean W.; Friedman, John D.; Germano, Guido; Slomka, Piotr J.

    2010-01-01

    Background The relationship between luminal stenosis measured by coronary CT angiography (CCTA) and severity of stress-induced ischemia seen on single photon emission computed tomographic myocardial perfusion imaging (SPECT-MPI) is not clearly defined. We sought to evaluate the relationship between stenosis severity assessed by CCTA and ischemia on SPECT-MPI. Methods and Results ECG-gated CCTA (64 slice dual source CT) and SPECT-MPI were performed within 6 months in 292 patients (ages 26-91, 73% male) with no prior history of coronary artery disease. Maximal coronary luminal narrowing, graded as 0, ≥25%, 50%, 70%, or 90% visual diameter reduction, was consensually assessed by two expert readers. Perfusion defect on SPECT-MPI was assessed by computer-assisted visual interpretation by an expert reader using the standard 17 segment, 5 point-scoring model (stress perfusion defect of ≥5% = abnormal). By SPECT-MPI, abnormal perfusion was seen in 46/292 patients. With increasing stenosis severity, positive predictive value (PPV) increased (42%, 51%, and 74%, P = .01) and negative predictive value was relatively unchanged (97%, 95%, and 91%) in detecting perfusion abnormalities on SPECT-MPI. In a receiver operator curve analysis, stenosis of 50% and 70% were equally effective in differentiating between the presence and absence of ischemia. In a multivariate analysis that included stenosis severity, multivessel disease, plaque composition, and presence of serial stenoses in a coronary artery, the strongest predictors of ischemia were stenosis of 50-89%, odds ratio (OR) 7.31, P = .001, stenosis ≥90%, OR 34.05, P = .0001, and serial stenosis ≥50% OR of 3.55, P = .006. Conclusions The PPV of CCTA for ischemia by SPECT-MPI rises as stenosis severity increases. Luminal stenosis ≥90% on CCTA strongly predicts ischemia, while stenosis strongly predicts the absence of ischemia. Serial stenosis of ≥50% in a vessel may offer incremental value in addition to

  14. Spectral compression of single photons

    CERN Document Server

    Lavoie, Jonathan; Wright, Logan G; Fedrizzi, Alessandro; Resch, Kevin J

    2013-01-01

    Photons are critical to quantum technologies since they can be used for virtually all quantum information tasks: in quantum metrology, as the information carrier in photonic quantum computation, as a mediator in hybrid systems, and to establish long distance networks. The physical characteristics of photons in these applications differ drastically; spectral bandwidths span 12 orders of magnitude from 50 THz for quantum-optical coherence tomography to 50 Hz for certain quantum memories. Combining these technologies requires coherent interfaces that reversibly map centre frequencies and bandwidths of photons to avoid excessive loss. Here we demonstrate bandwidth compression of single photons by a factor 40 and tunability over a range 70 times that bandwidth via sum-frequency generation with chirped laser pulses. This constitutes a time-to-frequency interface for light capable of converting time-bin to colour entanglement and enables ultrafast timing measurements. It is a step toward arbitrary waveform generatio...

  15. Imaging of soft-tissue tumors using L-3-[iodine-123]iodo-alpha-methyl-tyrosine single photon emission computed tomography: comparison with proliferative and mitotic activity, cellularity, and vascularity.

    NARCIS (Netherlands)

    Jager, P L; Plaat, B E; Vries, E G de; Molenaar, W M; Vaalburg, W; Piers, D A; Hoekstra, H J

    2000-01-01

    The radiolabeled amino acid L-3-[123I]-iodo-alpha-methyltyrosine (IMT) is a new tumor tracer that accumulates in many tumors and is suitable for single photon emission computed tomography (SPECT) imaging. Using IMT SPECT, we studied 32 patients with a soft-tissue tumor suspected to be a soft-tissue

  16. Simple partial status epilepticus localized by single-photon emission computed tomography subtraction in chronic cerebral paragonimiasis.

    Science.gov (United States)

    Joo, Eun Yeon; Kim, Jee Hyun; Tae, Woo Suk; Han, Sun Jung; Kim, Seunghwan; Kim, Myoung-Hee; Byun, Hong Sik; Hong, Seung Bong

    2004-10-01

    A patient with chronic cerebral paragonimiasis began to have new motor seizures of the right face manifested by clonic contractions that occurred several hundred times a day, consistent with simple partial status epilepticus. Ictal electroencephalogram discharges started from the left frontal region and then spread to the left hemisphere with left frontal maximum. But clinical seizures were limited to the right face. The frequent partial seizures were controlled by the intravenous infusion of phenytoin. Brain magnetic resonance imaging showed multiple conglomerated round nodules with encephalomalacia in the left temporal and occipital lobes. Applying the technique of ictal-interictal single-photo emission computed tomography subtraction, the authors were able to localize the focal ictal-hyperperfusion on left precentral cortex adjacent to the lesions that correspond to the anatomical distribution of left face motor area.

  17. Relation of gender to physician use of test results and to the prognostic value of stress technetium 99m sestamibi myocardial single-photon emission computed tomography scintigraphy.

    Science.gov (United States)

    Travin, M I; Duca, M D; Kline, G M; Herman, S D; Demus, D D; Heller, G V

    1997-07-01

    We analyzed potential gender differences in the use and prognostic value of stress technetium 99m sestamibi tomography, image results, and cardiac event rates over a period of 15 +/- 8 months in 1226 men and 1151 women. Men had more abnormal tomographic images, but referral for catheterization and revascularization similarly increased in relation to the number of defects. Men and women with abnormal images had similar event rates, 19.6% and 18.2%, respectively, although men more often had myocardial infarction or cardiac death (7.6% vs 4.1 %, p < 0.05), whereas women had an increased likelihood of unstable angina or congestive heart failure (11.5% vs 7.6%, p < 0.05). Normal images predicted a low yearly rate of myocardial infarction or death: 1.7% for men and 0.8% for women. Image findings, particularly defect extent, were independent predictors of events in both groups. Thus, after stress Tc-99m sestamibi single-photon emission computed tomography perfusion imaging, there was no gender bias in referral for invasive procedures, and for both men and women image findings were strongly associated with prognostic outcome.

  18. Indium-111 antimyosin antibody imaging and thallium-201 imaging. A comparative myocardial scintigraphic study using single-photon emission computed tomography in patients with myocarditis and dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takehiko; Matsumori, Akira; Nohara, Ryuji; Konishi, Junji; Sasayama, Shigetake [Kyoto Univ. (Japan). Faculty of Medicine; Tamaki, Nagara

    1997-10-01

    Indium-111 antimyosin antibody imaging (a tracer of myocardial necrosis) and thallium-201 imaging (a tracer of myocardial perfusion) were compared in patients with myocarditis and dilated cardiomyopathy. The distribution of each tracer and antimyosin/thallium-201 overlapping were evaluated with single-photon emission computed tomography (SPECT). Scintigraphic data were classified into 5 patterns according to the distribution of both images and were compared with histologic findings of endomyocardial biopsy: AM-D, intense and diffuse antimyosin uptake and no perfusion abnormality (active myocarditis); AM-L, localized antimyosin uptake and no perfusion abnormality (active myocarditis); HM, no antimyosin uptake with or without perfusion abnormality (healed myocarditis); DCM-NH, diffuse antimyosin uptake and inhomogeneous thallium-201 uptake (dilated cardiomyopathy); DCM-PD, diffuse or localized antimyosin uptake and myocardial perfusion defect(s) (dilated cardiomyopathy). Patients with dilated-phase hypertrophic cardiomyopathy were frequently found in the DCM-PD group. Taken together, comparative antimyosin/thallium-201 SPECT images are useful for evaluating the activity of myocarditis and ongoing myocardial damage even in areas with no perfusion in patients with dilated cardiomyopathy. (author)

  19. Brain MRI and single photon emission computed tomography in severe athetotic cerebral palsy. A comparative study with mental and motor disorders

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Kazutaka; Tsuzura, Shigenobu [Metropolitan Medical Center of the Severely Handicapped, Fuchu, Tokyo (Japan); Matsuda, Hiroshi

    1995-07-01

    Single photon emission computed tomography (SPECT) using N-isopropyl-p-[{sup 123}I]-iodoamphetamine ({sup 123}I-IMP) was performed in twelve patients with severe athetotic cerebral palsy (Ath; 5 males and 7 females) who had both motor delay (unable to move) and mental retardation (I.Q, or D.Q, below 30). The neuroimaging findings of those patients were compared with those of patients mental and motor disorders. In five caes suffering from neonatal asphyxia, SPECT demonstrated a decreased regional cerebral blood flow (rCBF) in corpus striatum, thalamus, orbitofrontal areas, pericentral gyrus areas, prefrontal areas and medial temporal areas. In seven cases suffering from neonatal jaundice, SPECT demonstrated a decreased rCBF in orbito-frontal areas, prefrontal areas and medial temporal areas. SPECT showed hypoperfusion of peri-central gyrus areas in cases with complications of spastic palsy. The decreased rCBF in medial temporal areas mostly corresponded to an alteration in hippocampal formation as assessed by magnetic resonance imaging (MRI). Cases with hypoperfusion of bilateral medial temporal areas showed a lower score of language understanding than those with the unilateral damage. In cases with hypofusion of bilateral prefrontal areas and bilateral medial temporal areas, the grade of understanding of language was almost below 12 months. In cases with hypoperfusion of orbitofrontal areas, psychomotor hypersensitivity had been observed. Those results suggest that IMP-SPECT and MRI of the brain is useful tool for neurological assessment in handicapped patients with athetotic cerebral palsy. (author).

  20. The effect of the superficial temporal to middle cerebral artery bypass based on the data of motor activation single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Morimoto, Tetsuya; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    We evaluated and analyzed the effect of the superficial temporal to middle cerebral artery (STA-MCA) bypass for the pure motor function in the ischemic cerebrovascular diseases (CVDs) using the motor activation single photon emission computed tomography (SPECT). Motor activation SPECT was performed on the 25 cases with ischemic CVD treated with STA-MCA bypass. Motor activation SPECT studies using the finger opposition task on the affected side were performed before surgery, at 1 month, and at 3 months after the bypass. The result of the motor activation SPECT was expressed as negative and positive by the visual inspection. During the follow-up period (mean; 2.2 years), there has been no recurrent or worsening clinical symptom. Before bypass, 10 cases were positive in the motor activation SPECT. The other 15 cases were negative. At one month after bypass, 14 cases were positive in the motor activation SPECT. At three months after bypass, 23 cases were positive in the motor activation SPECT. Twenty-two cases showed the improvement of the resting CBF. STA-MCA bypass is useful for pure motor function in the ischemic CVDs based on the motor activation SPECT coupling with their clinical symptoms. (author)

  1. Receptor binding characterization of the benzodiazepine radioligand sup 125 I-Ro16-0154: Potential probe for SPECT (Single Photon Emission Computed Tomography) brain imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.W.; Woods, S.W.; Zoghbi, S.; Baldwin, R.M.; Innis, R.B. (Yale Univ., West Haven, CT (USA)); McBride, B.J. (Medi-Physics, Inc., Emeryville, CA (USA))

    1990-01-01

    The binding of an iodinated benzodiazepine (BZ) radioligand has been characterized, particularly in regard to its potential use as a neuroreceptor brain imaging agent with SPECT (Single Photon Emission Computed Tomography). Ro16-0154 is an iodine-containing BZ antagonist and a close analog of Ro15-1788. In tissue homogenates prepared from human and monkey brain, the binding of {sup 125}I-labeled Ro16-0154 was saturable, of high affinity, and had high ratios of specific to non-specific binding. Physiological concentrations of NaCl enhanced specific binding approximately 15% compared to buffer without this salt. Kinetic studies of association and dissociation demonstrated a temperature dependent decrease in affinity with increasing temperature. Drug displacement studies confirmed that {sup 125}I-Ro16-0154 binds to the central type BZ receptor: binding is virtually identical to that of {sup 3}H-Ro15-1788 except that {sup 125}I-Ro16-0154 shows an almost 10 fold higher affinity at 37{degree}C. These in vitro results suggest that {sup 123}I-labeled Ro16-0154 shows promise as a selective, high affinity SPECT probe of the brain's BZ receptor.

  2. Single photon emission computed tomography (SPECT) findings using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP) in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Hidemichi (Aichi Medical Univ., Nagakute (Japan))

    1993-05-01

    Sixteen schizophrenic patients, 16 atypical psychosis patients, and 16 healthy volunteers were subjected to single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-[[sup 123]I]iodoamphetamine ([sup 123]I-IMP). The basal ganglia region was in particular examined not only in transverse sections, but in coronal sections. Schizophrenics showed significantly decreased uptake rates in the bilateral frontal regions and increased uptakes in the bilateral basal ganglia. On the other hand, atypical psychotics had a reduced uptake rate only in the right thalamic region, compared to the controls. The increased uptake rates in the basal ganglia were associated with auditory hallucination, but gender difference, duration of illness and dose of neuroleptics had no influence on these SPECT findings. The results suggest that schizophrenics might have some lesions in the frontal area of the brain, whereas atypical psychotics might have no lesion in the frontal region but dysfunction in the right thalamic region. Subsequently, using only SPECT findings, all the cases were divided by cluster analysis into 4 groups and a residue group. Schizophrenics distributed mainly in the 2 groups that have lesion in the frontal regions. Atypical psychotics distributed principally in the other 2 groups that have alterations in the bilateral thalamic region. The present study suggests that schizophrenia and atypical psychosis might have different etiologies. (author).

  3. Three-dimensional stereotactic surface projection in the statistical analysis of single photon emission computed tomography data for distinguishing between Alzheimer's disease and depression.

    Science.gov (United States)

    Kirino, Eiji

    2017-06-22

    To evaluate usefulness of single photon emission computed tomography (SPECT) with three-dimensional stereotactic surface projection (3D-SSP) in distinguishing between Alzheimer's disease (AD) and depression. We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following: (1) the Minimal Mental State Examination; (2) the Hamilton Rating Scale for Depression; (3) Clinical Global Impression-Severity scale (CGI-S); and (4) SPECT imaging with 3D-SSP. The MMSE scores correlated significantly with the maximum Z-scores of AD-associated regions. CGI-S scores correlated significantly with the maximum Z-scores of depression-associated regions. Factor analysis identified three significant factors. Of these, Factor 1 could be interpreted as favouring a tendency for AD, Factor 2 as favouring a tendency for pseudo-dementia, and Factor 3 as favouring a depressive tendency. We investigated whether these patients could be categorized as types: Type A (true AD), Type B (pseudo-dementia), Type C (occult AD), and Type D (true depression). The factor scores in factor analysis supported the validity of this classification. Our results suggest that SPECT with 3D-SSP is highly useful for distinguishing between depression and depressed mood in the early stage of AD.

  4. Aortic knob width reflects left ventricular diastolic function assessed by gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion.

    Science.gov (United States)

    Kurisu, Satoshi; Higaki, Tadanao; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-04-01

    Aortic knob width on chest radiography represents the extent of aortic dialation and tortuosity of the aortic arch. We tested the hypothesis that aortic knob width reflected left ventricular (LV) diastolic function assessed by gated myocardial perfusion single photon emission computed tomography (SPECT) in patients with normal myocardial perfusion. One hundred and thirty patients with preserved LV ejection fraction and normal myocardial perfusion were enrolled in this study. Aortic knob width was measured along the horizontal line from the point of the lateral edge of the trachea to the left lateral wall of the aortic knob. The peak filling rate (PFR) and the one-third mean filling rate (1/3 MFR) were obtained as LV diastolic parameters. There were 114 male and 16 female patients. Age ranged from 43 to 88 years (69.9 ± 8.9 years). Aortic knob width ranged from 24.2 to 53.4 mm (37.6 ± 5.7 mm). There was a significant correlation between age and aortic knob width (r = 0.34, p perfusion.

  5. Dopamine D[sub 2]-receptors in human narcolepsy. A SPECT study with [sup 123]I-IB. [Single Photon Emission Computed Tomography. Iodobenzamide

    Energy Technology Data Exchange (ETDEWEB)

    Hublin, C. (Department of Ullanlinna Sleep Research Centre, Kivelae Hospital, Helsinki (Finland)); Launes, J. (Department of Neurology, Helsinki University Central Hospital (Finland)); Nikkinen, P. (Department of Clinical Chemistry, Division of Nuclear Medicine, Helsinki University Central Hospital (Finland)); Partinen, M. (Department of Neurological Unit of Kivelae Hospital, Helsinki (Finland))

    1994-09-01

    Increased dopamine D[sub 2] receptor binding in basal ganglia has been reported in human narcolepsy. These studies have been based on post-mortem material of 8 patients, most of them also medicated for narcolepsy. We studied six narcoleptics without stimulant or anticataplectic medication. The patients had an unambiguous history of cataplexy, and they were also studied polygraphically. Single photon emission computed tomography (SPECT) imaging was performed. The D[sub 2] receptor density wad determined by using [sup 123]I-iodobenzamide (IBZM). The control subjects were 8 unmedicated Parkinson patients with one-sided (hemiparkinsonian) clinical symptoms. The D[sub 2] receptor density in them is known to be normal or somewhat increased compared to healthy normals. The striatum/frontal D[sub 2] activity ratio was 1.331 [+-] 0.084 (with phantom study correction 2.101 [+-] 0.300) in the narcoleptic patients, and in the parkinsonian controls 1.321 [+-] 0.052 (2.067 [+-] 0.185) for the asymptomatic side and 1.335 [+-] 0.025 (2.117 [+-] 0.090) for the symptomatic side (i.e. contralateral to the side with the clinical extrapyramidal signs). There was no statistical difference between the groups or between the symptomatic and asymptomatic side in the Parkinson patients. Thus, our results differ from the earlier post-mortem studies. (au) (28 refs.).

  6. Rapid and efficient radiosynthesis of [{sup 123}I]I-PK11195, a single photon emission computed tomography tracer for peripheral benzodiazepine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Pimlott, Sally L. [Department of Clinical Physics, West of Scotland Radionuclide Dispensary, Western Infirmary, G11 6NT Glasgow (United Kingdom)], E-mail: s.pimlott@clinmed.gla.ac.uk; Stevenson, Louise [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom); Wyper, David J. [Institute of Neurological Sciences, Southern General Hospital, G51 4TF Glasgow (United Kingdom); Sutherland, Andrew [Department of Chemistry, WestCHEM, University of Glasgow, G12 8QQ Glasgow (United Kingdom)

    2008-07-15

    Introduction: [{sup 123}I]I-PK11195 is a high-affinity single photon emission computed tomography radiotracer for peripheral benzodiazepine receptors that has previously been used to measure activated microglia and to assess neuroinflammation in the living human brain. This study investigates the radiosynthesis of [{sup 123}I]I-PK11195 in order to develop a rapid and efficient method that obtains [{sup 123}I]I-PK11195 with a high specific activity for in vivo animal and human imaging studies. Methods: The synthesis of [{sup 123}I]I-PK11195 was evaluated using a solid-state interhalogen exchange method and an electrophilic iododestannylation method, where bromine and trimethylstannyl derivatives were used as precursors, respectively. In the electrophilic iododestannylation method, the oxidants peracetic acid and chloramine-T were both investigated. Results: Electrophilic iododestannylation produced [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than achievable using the halogen exchange method investigated. Using chloramine-T as oxidant provided a rapid and efficient method of choice for the synthesis of [{sup 123}I]I-PK11195. Conclusions: [{sup 123}I]I-PK11195 has been successfully synthesized via a rapid and efficient electrophilic iododestannylation method, producing [{sup 123}I]I-PK11195 with a higher isolated radiochemical yield and a higher specific activity than previously achieved.

  7. Direct evaluation of adrenocortical function by measurement of adrenal percent uptake of sup 131 I-6. beta. -iodomethyl-19-norcholesterol using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ishimura, Junji (Hyogo Coll. of Medicine, Nishinomiya (Japan))

    1990-12-01

    In 55 patients (110 adrenal glands) with suspected adrenocortical abnormalities, I assessed the clinical usefulness of adrenal percent uptake of {sup 131}I-6{beta}-iodomethyl-19-norcholesterol (NCL-6-{sup 131}I) by single photon emission computed tomography (SPECT). The percent uptake of NCL-6-{sup 131}I in 6 hyperfunctioning glands of patients with the final diagnosis of Cushing's syndrome (2.62{+-}1.13(SD)%) was significantly (p<0.01) higher than that in 10 glands of patients with the final diagnosis of adenoma of primary aldosteronism (1.16{+-}0.09(SD)%). Moreover, the percent uptake of NCL-6-{sup 131}I in adrenal glands with hyperfunctioning lesions was significantly (p<0.01) higher than those in 10 contralateral normal glands of primary aldosteronism (0.55{+-}0.23(SD)%), 30 right glands (0.57{+-}0.24(SD)%) and 30 left glands (0.53{+-}0.22(SD)%) of essential hypertension with normally functioning adrenal cortices. The adrenal percent uptake of NCL-6-{sup 131}I in 24 glands with hypofunctioning adrenal cortices, including 4 glands suppressed by adenomas of Cushing's syndrome, was below the detectable limit. The data presented above show that the adrenocortical function can be evaluated directly based on measurement of adrenal percent uptake of NCL-6-{sup 131}I using SPECT. (author).

  8. Phantom study of thallium-201 myocadial single photon emission computed tomography for evaluating its ability to quantify residual myocardium in infarct area

    Energy Technology Data Exchange (ETDEWEB)

    Ohtake, Tohru; Watanabe, Toshiaki; Kosaka, Noboru; Momose, Toshimitsu; Nishikawa, Junichi; Iio, Masahiro

    1988-03-01

    We studied the relationship between the count of myocardial wall in single photon emission computed tomography (SPECT) image and the thickness of wall or the concentration of Thallium-201 (Tl) in wall. For this purpose, we used phantom of thorax and myocardium. Thoracic phantom consists of mediastinum filled with low concentrated Tl solution and lung filled with wooden tip. Myocardial phantom consists of eight parts (upper and lower parts of anterior wall, septum, posteroinferior wall and lateral wall). In one phantom we changed the thickness of wall (10 mm, 7.5 mm, 5 mm, 2.5 mm, 0 mm) and in another phantom we changed the Tl concentration (100 %, 75 %, 50 %, 25 %, 0 %). In our results, the thickness and the concentration correlated well with the count and five grades (100 %, 75 %, 50 %, 25 %, 0 %) were well separated though it was said that SPECT is inaccurate in quantification. But in 180 deg half scan, the count of upper part was 10 - 15 % lower than that of lower part and the count of posteroinferior wall was about 10 % lower than that of anterior wall. We have to take it into account in quantification. In conclusion, using Tl-201 myocardial SPECT residual myocardium in infarct area can be evaluated from the severity of defect, and from that the severity of ischemia can be evaluated.

  9. Investigation of the effects of attenuation correction on the compatibility of two single photon emission computed tomography systems with the use of segmentation through registration

    Science.gov (United States)

    Lampaskis, M.; Killilea, K.; Metherall, P.; Harris, A.; Barber, D.

    2011-09-01

    The aim of this work was to compare images acquired from two Single Photon Emission Computed Tomography (SPECT), performing attenuation correction using different systems, to evaluate the level at which images from these systems can be used on patients to assess myocardial perfusion. The two systems are the Siemens E-cam with profile attenuation correction and the General Electric Hawkeye system. This study was performed using an anthropomorphic torso phantom. The motivation was to examine if attenuation corrected images from these systems are comparable when assessing the myocardial function of patients, with different conditions regarding background (adjacent tissues) activity and the presence or not of defects on the cardiac wall. To perform the analysis of the acquired images specialized software were used to extract information relating to the activity distribution within the cardiac insert (simulated myocardium). This was based on standardized myocardial segmentation used clinically, by the application of image registration using an artificial reference model. The results show that adjacent tissue activity did not affect the ability to detect defects. Further, the application of attenuation correction may reduce the comparability of the two systems to a small degree.

  10. Dynamic Observation of the Three-Dimensional Distribution of Labeled Liposomes Using the Novel High-Resolution Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Andreas Wirrwar

    2008-09-01

    Full Text Available The aim of this study was to show that the multipinhole technique (high-resolution single-photon emission computed tomography [HiSPECT] is suitable for dynamic imaging of both biodistribution and temporal uptake behavior of radiolabeled cationic liposomes in Balb/c-mice. HiSPECT uses multipinhole collimators adapted to a clinical SPECT scanner, together with a dedicated iterative reconstruction program. This technique provides both high spatial resolution and an improvement in sensitivity. Six male Balb/c mice received 9.8 ± 4.0 MBq of the In 111-labeled liposomes. The measurements started directly after the injection and tomographic data were acquired in steps of 5 minutes. The regional evaluation displayed a high initial uptake of liposomes in the lungs (45.4%, which decreased to 25.1% after 30 minutes and to below 2% after 48 hours. In contrast, liver uptake increased in the first 30 minutes from 13.1 to 21.2% and remained relatively stable at 24.4% (24 hours and 18.8% (48 hours. The data are interpreted as a slow shift of liposomes from the lungs into the liver and later to other organs such as the spleen and bladder. This study shows that the HiSPECT technique is capable of dynamically visualizing the uptake behavior of radioactively labeled liposomes in vivo with high temporal and spatial resolution.

  11. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  12. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  13. Assessment of Gastric Accommodation in Patients with Functional Dyspepsia by 99mTc-Pertechtenate Single Photon Emission Computed Tomography Imaging: Practical but not Widely Accepted

    Directory of Open Access Journals (Sweden)

    Taghi Amiriani

    2015-10-01

    Full Text Available Objective: Impaired gastric accommodation is one of the main symptoms in patients with functional dyspepsia. The aim of the present study was to assess gastric accommodation in patients with functional dyspepsia using single photon emission computed tomography (SPECT imaging. Methods: Twenty-four patients with functional dyspepsia and 50 healthy volunteers as control group were enrolled in this study. All participants were given 5 mCi 99mTc-pertechtenate intravenously, served with a low fat meal, and underwent SPECT scanning 20 minutes after the meal. Results: Based on the scintigraphic data, gastric volumes were found to be significantly increased after food ingestion in both patient and control groups. We also found that while there was no significant difference between patient and control groups in terms of fasting gastric volumes, postprandial gastric volume was significantly lower in patients as compared to healthy individuals (p<0.05. Conclusion: Measuring gastric volume by using SPECT can be a valuable method in the detection of functional dyspepsia and in differentiation of this entity from other organic disorders.

  14. Conjugates of folic acids with BSA-coated quantum dots for cancer cell targeting and imaging by single-photon and two-photon excitation.

    Science.gov (United States)

    Meng, He; Chen, Ji-Yao; Mi, Lan; Wang, Pei-Nan; Ge, Mei-Ying; Yue, Yang; Dai, Ning

    2011-01-01

    Bovine serum albumin (BSA)-coated CdTe/ZnS quantum dots (BSA-QDs) were selected to conjugate with folic acid (FA), forming FA-BSA-QDs. This study aims to develop these small FA-BSA-QDs (less than 10 nm) for the diagnosis of cancers in which the FA receptor (FR) is overexpressed. The enhancement of cellular uptake in FR-positive human nasopharyngeal carcinoma cells (KB cells) for FA-BSA-QDs was found by means of confocal fluorescence microscopy under single-photon and two-photon excitation. The uptake enhancement for FA-BSA-QDs was further evaluated by flow-cytometric analysis in 10(4) KB cells, and was about 3 times higher than for BSA-QDs on average. The uptake enhancement was suppressed when KB cells had been pretreated with excess FA, reflecting that the enhancement was mediated by the association of FR at cell membranes with FA-BSA-QDs. When human embryonic kidney cells (293T) (FR-negative cells) and KB cells, respectively, were incubated with FA-BSA-QDs (1 μM) for 40 min, the FA-BSA-QD uptake by 293T cells was much weaker than that by KB cells, demonstrating that FA-BSA-QDs could undergo preferential binding on FR-positive cancer cells. These characteristics suggest that FA-BSA-QDs are potential candidates for cancer diagnosis.

  15. Application of Chang's attenuation correction technique for single-photon emission computed tomography partial angle acquisition of Jaszczak phantom

    Directory of Open Access Journals (Sweden)

    Krishnendu Saha

    2016-01-01

    Full Text Available The acquisition and processing of the Jaszczak phantom is a recommended test by the American College of Radiology for evaluation of gamma camera system performance. To produce the reconstructed phantom image for quality evaluation, attenuation correction is applied. The attenuation of counts originating from the center of the phantom is greater than that originating from the periphery of the phantom causing an artifactual appearance of inhomogeneity in the reconstructed image and complicating phantom evaluation. Chang's mathematical formulation is a common method of attenuation correction applied on most gamma cameras that do not require an external transmission source such as computed tomography, radionuclide sources installed within the gantry of the camera or a flood source. Tomographic acquisition can be obtained in two different acquisition modes for dual-detector gamma camera; one where the two detectors are at 180° configuration and acquire projection images for a full 360°, and the other where the two detectors are positioned at a 90° configuration and acquire projections for only 180°. Though Chang's attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor's camera software producing artifacts in the images. This work investigates whether Chang's attenuation correction technique can be applied to both acquisition modes by the development of a Chang's formulation-based algorithm that is applicable to both modes. Assessment of attenuation correction performance by phantom uniformity analysis illustrates improved uniformity with the proposed algorithm (22.6% compared to the camera software (57.6%.

  16. Reduction of metal artifact in single photon-counting computed tomography by spectral-driven iterative reconstruction technique.

    Directory of Open Access Journals (Sweden)

    Radin A Nasirudin

    Full Text Available The exciting prospect of Spectral CT (SCT using photon-counting detectors (PCD will lead to new techniques in computed tomography (CT that take advantage of the additional spectral information provided. We introduce a method to reduce metal artifact in X-ray tomography by incorporating knowledge obtained from SCT into a statistical iterative reconstruction scheme. We call our method Spectral-driven Iterative Reconstruction (SPIR.The proposed algorithm consists of two main components: material decomposition and penalized maximum likelihood iterative reconstruction. In this study, the spectral data acquisitions with an energy-resolving PCD were simulated using a Monte-Carlo simulator based on EGSnrc C++ class library. A jaw phantom with a dental implant made of gold was used as an object in this study. A total of three dental implant shapes were simulated separately to test the influence of prior knowledge on the overall performance of the algorithm. The generated projection data was first decomposed into three basis functions: photoelectric absorption, Compton scattering and attenuation of gold. A pseudo-monochromatic sinogram was calculated and used as input in the reconstruction, while the spatial information of the gold implant was used as a prior. The results from the algorithm were assessed and benchmarked with state-of-the-art reconstruction methods.Decomposition results illustrate that gold implant of any shape can be distinguished from other components of the phantom. Additionally, the result from the penalized maximum likelihood iterative reconstruction shows that artifacts are significantly reduced in SPIR reconstructed slices in comparison to other known techniques, while at the same time details around the implant are preserved. Quantitatively, the SPIR algorithm best reflects the true attenuation value in comparison to other algorithms.It is demonstrated that the combination of the additional information from Spectral CT and

  17. Dystrophic calcification in muscles of legs in calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly, and telangiectasia syndrome: Accurate evaluation of the extent with (99m)Tc-methylene diphosphonate single photon emission computed tomography/computed tomography.

    Science.gov (United States)

    Chakraborty, Partha Sarathi; Karunanithi, Sellam; Dhull, Varun Singh; Kumar, Kunal; Tripathi, Madhavi

    2015-01-01

    We present the case of a 35-year-old man with calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly and telangiectasia variant scleroderma who presented with dysphagia, Raynaud's phenomenon and calf pain. (99m)Tc-methylene diphosphonate bone scintigraphy was performed to identify the extent of the calcification. It revealed extensive dystrophic calcification in the left thigh and bilateral legs which was involving the muscles and was well-delineated on single photon emission computed tomography/computed tomography. Calcinosis in scleroderma usually involves the skin but can be found in deeper periarticular tissues. Myopathy is associated with a poor prognosis.

  18. Single photon source characterization with a superconducting single photon detector

    CERN Document Server

    Hadfield, R H; Miller, A J; Mirin, R P; Nam, S W; Schwall, R E; Stevens, M J; Gruber, Steven S.; Hadfield, Robert H.; Miller, Aaron J.; Mirin, Richard P.; Nam, Sae Woo; Schwall, Robert E.; Stevens, Martin J.

    2005-01-01

    Superconducting single photon detectors (SSPD) based on nanopatterned niobium nitride wires offer single photon counting at fast rates, low jitter, and low dark counts, from visible wavelengths well into the infrared. We demonstrate the first use of an SSPD, packaged in a commercial cryocooler, for single photon source characterization. The source is an optically pumped, microcavity-coupled InGaAs quantum dot, emitting single photons on demand at 902 nm. The SSPD replaces the second silicon Avalanche Photodiode (APD) in a Hanbury-Brown Twiss interferometer measurement of the source second-order correlation function, g (2) (tau). The detection efficiency of the superconducting detector system is >2 % (coupling losses included). The SSPD system electronics jitter is 170 ps, versus 550 ps for the APD unit, allowing the source spontaneous emission lifetime to be measured with improved resolution.

  19. Simulating single photons with realistic photon sources

    Science.gov (United States)

    Yuan, Xiao; Zhang, Zhen; Lütkenhaus, Norbert; Ma, Xiongfeng

    2016-12-01

    Quantum information processing provides remarkable advantages over its classical counterpart. Quantum optical systems have been proved to be sufficient for realizing general quantum tasks, which, however, often rely on single-photon sources. In practice, imperfect single-photon sources, such as a weak-coherent-state source, are used instead, which will inevitably limit the power in demonstrating quantum effects. For instance, with imperfect photon sources, the key rate of the Bennett-Brassard 1984 (BB84) quantum key distribution protocol will be very low, which fortunately can be resolved by utilizing the decoy-state method. As a generalization, we investigate an efficient way to simulate single photons with imperfect ones to an arbitrary desired accuracy when the number of photonic inputs is small. Based on this simulator, we can thus replace the tasks that involve only a few single-photon inputs with the ones that make use of only imperfect photon sources. In addition, our method also provides a quantum simulator to quantum computation based on quantum optics. In the main context, we take a phase-randomized coherent state as an example for analysis. A general photon source applies similarly and may provide some further advantages for certain tasks.

  20. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  1. Voxel-Based Correlation between Coregistered Single-Photon Emission Computed Tomography and Dynamic Susceptibility Contrast Magnetic Resonance Imaging in Subjects with Suspected Alzheimer Disease

    Energy Technology Data Exchange (ETDEWEB)

    Cavallin, L.; Axelsson, R.; Wahlund, L.O.; Oeksengard, A.R.; Svensson, L.; Juhlin, P.; Wiberg, M. Kristoffersen; Frank, A. [Division of Radiology, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden)

    2008-12-15

    Background: Current diagnosis of Alzheimer disease is made by clinical, neuropsychologic, and neuroimaging assessments. Neuroimaging techniques such as magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) could be valuable in the differential diagnosis of Alzheimer disease, as well as in assessing prognosis. Purpose: To compare SPECT and MRI in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer disease (AD). Material and Methods: 24 patients, eight with AD, 10 with MCI, and six controls, were investigated with SPECT using {sup 99m}Tc-hexamethylpropyleneamine oxime (HMPAO, Ceretec; GE Healthcare Ltd., Little Chalsont UK) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a contrast-enhancing gadobutrol formula (Gadovist; Bayer Schering Pharma, Berlin, Germany). Voxel-based correlation between coregistered SPECT and DSC-MR images was calculated. Region-of-interest (ROI) analyses were then performed in 24 different brain areas using brain registration and analysis of SPECT studies (BRASS; Nuclear Diagnostics AB, Stockholm (SE)) on both SPECT and DSC-MRI. Results: Voxel-based correlation between coregistered SPECT and DSC-MR showed a high correlation, with a mean correlation coefficient of 0.94. ROI analyses of 24 regions showed significant differences between the control group and AD patients in 10 regions using SPECT and five regions in DSC-MR. Conclusion: SPECT remains superior to DSC-MRI in differentiating normal from pathological perfusion, and DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer disease.

  2. Voxel-Based Correlation between Coregistered Single-Photon Emission Computed Tomography and Dynamic Susceptibility Contrast Magnetic Resonance Imaging in Subjects with Suspected Alzheimer Disease

    Energy Technology Data Exchange (ETDEWEB)

    Cavallin, L.; Axelsson, R.; Wahlund, L.O.; Oeksengard, A.R.; Svensson, L.; Juhlin, P.; Wiberg, M. Kristoffersen; Frank, A. (Division of Radiology, Karolinska Inst., Karolinska Univ. Hospital, Stockholm (Sweden))

    2008-12-15

    Background: Current diagnosis of Alzheimer disease is made by clinical, neuropsychologic, and neuroimaging assessments. Neuroimaging techniques such as magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) could be valuable in the differential diagnosis of Alzheimer disease, as well as in assessing prognosis. Purpose: To compare SPECT and MRI in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer disease (AD). Material and Methods: 24 patients, eight with AD, 10 with MCI, and six controls, were investigated with SPECT using 99mTc-hexamethylpropyleneamine oxime (HMPAO, Ceretec; GE Healthcare Ltd., Little Chalsont UK) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a contrast-enhancing gadobutrol formula (Gadovist; Bayer Schering Pharma, Berlin, Germany). Voxel-based correlation between coregistered SPECT and DSC-MR images was calculated. Region-of-interest (ROI) analyses were then performed in 24 different brain areas using brain registration and analysis of SPECT studies (BRASS; Nuclear Diagnostics AB, Stockholm (Sweden)) on both SPECT and DSC-MRI. Results: Voxel-based correlation between coregistered SPECT and DSC-MR showed a high correlation, with a mean correlation coefficient of 0.94. ROI analyses of 24 regions showed significant differences between the control group and AD patients in 10 regions using SPECT and five regions in DSC-MR. Conclusion: SPECT remains superior to DSC-MRI in differentiating normal from pathological perfusion, and DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer disease

  3. Measurement of porto-systemic shunting in mice by novel three-dimensional micro-single photon emission computed tomography imaging enabling longitudinal follow-up.

    Science.gov (United States)

    Van Steenkiste, Christophe; Staelens, Steven; Deleye, Steven; De Vos, Filip; Vandenberghe, Stefaan; Geerts, Anja; Van de Wiele, Christophe; De Vos, Martine; Van Vlierberghe, Hans; Colle, Isabelle

    2010-09-01

    The reference method for diagnosing porto-systemic shunting (PSS) in experimental portal hypertension involves measuring (51)Chrome ((51)Cr)-labelled microspheres. Unfortunately, this technique necessitates the sacrifice of animals. Alternatively, (99m)technetium-macroaggregated albumin ((99m)Tc-MAA) has been used; however, planar scintigraphy imaging techniques are not quantitatively accurate and adequate spatial information is not attained. Here, we describe a reliable, minimally invasive and rapid in vivo imaging technique, using three-dimensional single photon emission computed tomography (3D SPECT) modus, that allows more accurate quantification, serial measurements and spatial discrimination. Partial portal vein ligation, common bile duct ligation and sham were induced in male mice. A mixture of (51)Cr microspheres and (99m)Tc-macroaggregated albumin particles was injected into the splenic pulpa. All mice were scanned in vivo with microSPECT (1 mm spatial resolution) and, when mandatory for localisation, a microSPECT-CT was acquired. A relative quantitative analysis was performed based on the 3D reconstructed datasets. Additionally, (51)Cr was measured in the same animals to calculate the correlation coefficient between the (99m)Tc detection and the gold standard (51)Cr. In each measuring modality, the PSS fraction was calculated using the formula: [(lung counts)/(lung counts+liver counts)] x 100. A significant correlation between the (99m)Tc detection and (51)Cr was demonstrated in partial portal vein ligation, common bile duct ligation and sham mice and there was a good agreement between the two modalities. MicroSPECT scanning delivers high spatial resolution and 3D image reconstructions. We have demonstrated that quantitative high-resolution microSPECT imaging with (99m)Tc-MAA is useful for detecting the extent of PSS in a non-sacrificing set-up. This technology permits serial measurements and high-throughput screening to detect baseline PSS, which is

  4. Correlative single photon emission computed tomography imaging of [{sup 123}I]altropane binding in the rat model of Parkinson's

    Energy Technology Data Exchange (ETDEWEB)

    Gleave, Jacqueline A. [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada); Farncombe, Troy H.; Saab, Chantal [Department of Nuclear Medicine, Hamilton Health Sciences, Hamilton, Ontario, L8N 3Z5 (Canada); Doering, Laurie C., E-mail: doering@mcmaster.ca [Department of Pathology and Molecular Medicine, McMaster University, 1200 Main Street West, Hamilton, Ontario, L8N 3Z5 (Canada)

    2011-07-15

    Introduction: This study used the dopamine transporter (DAT) probe, [{sup 123}I]-2{beta}-carbomethoxy-3{beta}-(4-fluorophenyl)-N-(3-iodo-E-allyl)nortropane ([{sup 123}I]altropane), to assess the DAT levels in the 6-hydroxydopamine rat model of Parkinson's disease. We sought to assess if the right to left [{sup 123}I]altropane striatal ratios correlated with dopamine content in the striatum and substantia nigra and with behavioural outcomes. Methods: [{sup 123}I]altropane images taken pre- and postlesion were acquired before and after the transplantation of neural stem/progenitor cells. The images obtained using [{sup 123}I]altropane and single photon emission computed tomography (SPECT) were compared with specific behavioural tests and the dopamine content assessed by high-performance liquid chromatography. Results: [{sup 123}I]altropane binding correlated with the content of dopamine in the striatum; however, [{sup 123}I]altropane binding did not correlate with the dopamine content in the substantia nigra. There was a significant correlation of altropane ratios with the cylinder test and the postural instability test, but not with amphetamine rotations. The low coefficient of determination (r{sup 2}) for these correlations indicated that [{sup 123}I]altropane SPECT was not a good predictor of behavioural outcomes. Conclusion: Our data reveal that [{sup 123}I]altropane predicts the integrity of the striatal dopamine nerve terminals, but does not predict the integrity of the nigrostriatal system. [{sup 123}I]altropane could be a useful marker to measure dopamine content in cell replacement therapies; however, it would not be able to evaluate outcomes for neuroprotective strategies.

  5. Quantifying regional cerebral blood flow by N-isopropyl-P-[I-123]iodoamphetamine (IMP) using a ring type single-photon emission computed tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N.; Odano, I.; Ohkubo, M. [Niigata Univ. (Japan)] [and others

    1994-05-01

    We developed a more accurate quantitative measurement of regional cerebral blood flow (rCBF) with the microsphere model using N-isopropyl-p-[I-123] iodoamphetamine (IMP) and a ring type single photon emission computed tomography (SPECT) system. SPECT studies were performed in 17 patients with brain diseases. A dose of 222 MBq (6 mCi) of [I-123]IMP was injected i.v., at the same time a 5 min period of arterial blood withdrawal was begun. SPECT data were acquired from 25 min to 60 min after tracer injection. For obtaining the brain activity concentration at 5 min after IMP injection, total brain counts collections and one minute period short time SPECT studies were performed at 5, 20, and 60 min. Measurement of the values of rCBF was calculated using short time SPECT images at 5 min (rCBF), static SPECT images corrected with total cerebral counts (rCBF{sub Ct}.) and those corrected with reconstructed counts on short time SPECT images (rCBF{sub Cb}). There was a good relationship (r=0.69) between rCBF and rCBF{sub Ct}, however, rCBF{sub Ct} tends to be underestimated in high flow areas and overestimated in low flow areas. There was better relationship between rCBF and rCBF{sub Cb}(r=0.92). The overestimation and underestimation shown in rCBF{sub Ct} was considered to be due to the correction of reconstructed counts using a total cerebral time activity curve, because of the kinetic behavior of [I-123]IMP was different in each region. We concluded that more accurate rCBF values could be obtained using the regional time activity curves.

  6. Redistribution in I-123 N-isopropyl-p iodoamphetamine single-photon emission computed tomography in cerebrovascular disease and the effects of rehabilitation

    Energy Technology Data Exchange (ETDEWEB)

    Fukumitsu, N.; Kawakami, G.; Uchiyama, M.; Mori, Y. [Dept. of Radiology, Jikei University School of Medicine, Tokyo (Japan); Ogi, S. [Dept. of Radiology, Ichikawa Hospital of Tokyo Dental University, Tokyo (Japan); Takehara, I.; Miyano, S. [Dept. of Rehabilitation Medicine, Jikei Daisan Hospital (Japan); Katagiri, N. [Dept. of Rehabilitation Medicine, Kanagawa Rehabilitation Centre (Japan)

    2001-06-01

    We performed N-isopropyl-p (I-123) iodoamphetamine (IMP) single-photon emission computed tomography (SPECT) on 28 patients with severe cerebrovascular disease before rehabilitation, and compared the degree of redistribution and the assessment of activities of daily living (ADL). We calculated a redistribution (RD) ratio in the central and peripheral parts of the lesions: RD ratio (c) and RD ratio (p). We classified the patients into four groups based on the degree of redistribution: complete: both RD ratio (c) and (p) {>=} 75; peripheral: RD ratio (c) < 75, RD ratio (p) {>=} 75; incomplete: both RD ratio (c) and (p) < 75 and at least one of RD ratio (c) or (p) {>=} 25; no redistribution: both RD ratio (c) and (p) < 25. We assessed the ADL using the modified Barthel index (BI). {delta}BI was defined as BI after rehabilitation-BI before rehabilitation (BIpost-BIpre). The {delta}BI of the four groups were as follows: complete-redistribution group (40.8 {+-} 22.8), peripheral-redistribution group (40.0 {+-} 15.8), incomplete-redistribution group (27.2 {+-} 22.6), no-redistribution group (8.8 {+-} 12.3). The {delta}BI of the complete and peripheral redistribution groups were significantly higher than that of the no-redistribution group. However, {delta}BI was almost the same in the complete- and peripheral-redistribution groups. This suggests that the effect of rehabilitation might be closely related to the viability of the peripheral part of the lesion. (orig.)

  7. Clinical studies on thallium-201 myocardial single-photon emission computed tomography in patients with ischemic heart disease. Clinical evaluation using the polar map method

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Naohiko

    1987-06-01

    In order to evaluate briefly the relative 3-dimensional distribution of /sup 201/Tl in the myocardium, a 2-dimensional polar map was developed from short axis tomograms of single-photon emission computed tomography (SPECT) using circumferential profile analysis. The data collected from 180 deg rotational scan around a body were used in clinical study to acquire the projection data in a short time, although, with a heart phantom study, there was more uniformity with the 360 deg collection than with 180 deg collection. So, the polar map of relative distribution and % washout rate (% WR) were created from 180 deg data collection. To detect ischemic area, the lower limit (M-SD) of the profile curve in 10 normal subjects was processed and compared with that of patients. Then, abnormal /sup 201/Tl distribution and % WR were identified comparing each patient's profile with the corresponding normal lower limits. In 24 patients with myocardial infarction, defect score (DS), estimated as infarcted size from the relative polar map, was compared with the size of abnormal wall motion in left ventriculography. There was a good correlation (r = 0.834) between them. Also, there were close correlations between DS and regional contraction (r = -0.869), and between DS and left ventricular ejection fraction (r = -0.775) respectively. In 24 patients with non-MI angina pectoris, the diagnostic sensitivity of exercise induced ischemia was 65 % and accuracy was 76 % by relative distribution map. However, the sensitivity of % WR map was superior (84 %) to that of relative map, especially in the patients with mild ischemia and multi-vessel disease. In conclusion, this comprehensive polar map method represented well a 3-dimensional myocardial distribution of /sup 201/Tl. The clinical usefulness in determination of infarct size and in diagnosis of myocardial ischemia were evaluated.

  8. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  9. Diagnostic imaging of dementia with Lewy bodies by susceptibility-weighted imaging of nigrosomes versus striatal dopamine transporter single-photon emission computed tomography: a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Sato, Kanako; Suzuki, Michimasa; Hori, Masaaki; Kumamaru, Kanako K.; Aoki, Shigeki [Juntendo University Graduate School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Nakatsuka, Tomoya; Inaoka, Tsutomu; Terada, Hitoshi [Toho University Sakura Medical Center, Department of Radiology, Sakura, Sakura (Japan); Sakakibara, Ryuji; Tsuyusaki, Yohei [Toho University Sakura Medical Center, Department of Neurology, Sakura, Sakura (Japan); Takamura, Tomohiro [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan)

    2017-01-15

    The characteristics of dementia with Lewy bodies (DLB), Alzheimer's disease (AD) and amnestic mild cognitive impairment (a-MCI) overlap but require different treatments; therefore, it is important to differentiate these pathologies. Assessment of dopamine uptake in the striatum using dopamine transporter (DaT) single-photon emission computed tomography (SPECT) is the gold standard for diagnosing DLB; however, this modality is expensive, time consuming and involves radiation exposure. Degeneration of the substantia nigra nigrosome-1, which occurs in DLB, but not in AD/a-MCI, can be identified by 3T susceptibility-weighted imaging (SWI). Therefore, the aim of this retrospective observational study was to compare SWI with DaT-SPECT for differentiation of DLB from AD/a-MCI. SWI data were acquired for patients with clinically diagnosed DLB (n = 29), AD (n = 18), a-MCI (n = 13) and healthy controls (n = 26). Images were analysed for nigrosome-1 degeneration. Diagnostic accuracy was evaluated for DLB, AD and a-MCI compared with striatal dopamine uptake using DaT-SPECT. SWI achieved 90% diagnostic accuracy (93% sensitivity, 87% specificity) for the detection of nigrosome-1 degeneration in DLB and not in AD/a-MCI as compared with 88.3% accuracy (93% sensitivity, 84% specificity) using DaT-SPECT. SWI nigrosome-1 evaluation was useful in differentiating DLB from AD/a-MCI, with high accuracy. This less invasive and less expensive method is a potential alternative to DaT-SPECT for the diagnosis of DLB. (orig.)

  10. Preliminary clinical study in patients with hemispatial neglect after stroke by neglect test battery and 99mTc-ECD single-photon emission computed tomography.

    Science.gov (United States)

    Yin, Yafu; Li, Xuena; Li, Yaming; Gu, Hui; Han, Chunqi; Liu, Hao

    2009-05-01

    To explore the presence, clinical characteristics, anatomical foci in image and mechanism of hemispatial neglect (HSN), neglect test battery and single-photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) imaging were performed on patients with stroke. Thirty dextromanual patients who were diagnosed as having unilateral stroke clinically were recruited. A neglect test battery including line bisection test, star cancellation test and drawing test was performed on the subjects. The severity of neglect was measured on neglect tests. The lowest rCBF, the range with decreased rCBF, number of the foci with decreased rCBF, the flow deficit size and the total number of pixels in the foci were measured on SPECT rCBF imaging. Twenty-five patients were diagnosed as having HSN by the neglect test battery. Contralateral neglect (CN) and ipsilateral neglect (IN) were observed in both right and left hemisphere strokes. On SPECT imaging, the patients with neglect had decreased rCBF in the frontal cortex most often; followed by the parietal, occipital and temporal cortices; and basal ganglia and thalamus in some cases. The patients who had two or more regions damaged showed neglect more often and severity. The correlation coefficients between rCBF in the foci, the decreased percentage of rCBF of the foci and the severity of neglect were -0.119 (P>.05) and 0.221 (P>.05). The correlation coefficients between the range, number of foci, the flow deficit size, the total number of pixels of the foci and the severity of neglect were 0.537 (Prange, number of foci, the flow deficit size and the total numbers of pixels of the foci significantly. And the patients with CN and IN did not show any difference in the presence of HSN, the manifestation on the neglect test battery and SPECT images. HSN showed damage on multiple sites, with combined damages resulting in more severe neglect.

  11. Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.

    Science.gov (United States)

    Sommerauer, Michael; Graf, Carmen; Schäfer, Niklaus; Huber, Gerhard; Schneider, Paul; Wüthrich, Rudolf; Schmid, Christoph; Steinert, Hans

    2015-01-01

    Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 ± 46 vs. 129 ± 41 minutes, p = 0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.

  12. SemiSPECT: a small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays.

    Science.gov (United States)

    Kim, Hyunki; Furenlid, Lars R; Crawford, Michael J; Wilson, Donald W; Barber, H Bradford; Peterson, Todd E; Hunter, William C J; Liu, Zhonglin; Woolfenden, James M; Barrett, Harrison H

    2006-02-01

    The first full single-photon emission computed tomography (SPECT) imager to exploit eight compact high-intrinsic-resolution cadmium zinc telluride (CZT) detectors, called SemiSPECT, has been completed. Each detector consists of a CZT crystal and a customized application-specific integrated circuit (ASIC). The CZT crystal is a 2.7 cm x 2.7 cm x -0.2 cm slab with a continuous top electrode and a bottom electrode patterned into a 64 x 64 pixel array by photolithography. The ASIC is attached to the bottom of the CZT crystal by indium-bump bonding. A bias voltage of -180 V is applied to the continuous electrode. The eight detectors are arranged in an octagonal lead-shielded ring. Each pinhole in the eight-pinhole aperture placed at the center of the ring is matched to each individual detector array. An object is imaged onto each detector through a pinhole, and each detector is operated independently with list-mode acquisition. The imaging subject can be rotated about a vertical axis to obtain additional angular projections. The performance of SemiSPECT was characterized using 99mTc. When a 0.5 mm diameter pinhole is used, the spatial resolution on each axis is about 1.4 mm as estimated by the Fourier crosstalk matrix, which provides an algorithm-independent average resolution over the field of view. The energy resolution achieved by summing neighboring pixel signals in a 3 x 3 window is about 10% full-width-at-half-maximum of the photopeak. The overall system sensitivity is about 0.5 x 10(-4) with the energy window of +/-10% from the photopeak. Line-phantom images are presented to visualize the spatial resolution provided by SemiSPECT, and images of bone, myocardium, and human tumor xenografts in mice demonstrate the feasibility of preclinical small-animal studies with SemiSPECT.

  13. Impact of Gender on the Prognostic Value of Coronary Artery Calcium in Symptomatic Patients With Normal Single-Photon Emission Computed Tomography Myocardial Perfusion.

    Science.gov (United States)

    Engbers, Elsemiek M; Timmer, Jorik R; Ottervanger, Jan Paul; Mouden, Mohamed; Knollema, Siert; Jager, Pieter L

    2016-12-01

    The coronary artery calcium (CAC) score provides independent prognostic value on top of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). We sought to determine whether the prognostic value of the CAC score in patients with normal SPECT MPI is gender specific. We studied 3,705 consecutive symptomatic patients without a history of coronary artery disease with normal SPECT MPI. All patients underwent concomitant CAC scoring, which was categorized as CAC score 0, 1 to 99, 100 to 399, 400 to 999, or ≥1,000. Major adverse cardiac events were defined as revascularization, nonfatal myocardial infarction, or all-cause mortality. The median CAC score was 9 in women (interquartile range 0 to 113) and 47 in men (interquartile range 1 to 307, p CAC score, annual event rates were similar (for women and men, respectively: CAC score 0, 0.6% and 0.5%, p = 0.95; CAC score 1 to 99, 0.9% and 1.2%, p = 0.45; CAC score 100 to 399, 2.7% and 3.8%, p = 0.23; CAC score 400 to 999, 3.8% and 5.3%, p = 0.34; CAC score ≥1,000, 8.4% and 8.7%, p = 0.99). The CAC score was an independent predictor of major adverse cardiac events in both genders (CAC score ≥1,000: hazard ratio for women 8.5, 95% confidence interval 4.0 to 18.1; hazard ratio for men 14.8, 95% confidence interval 5.3 to 41.1). In conclusion, risk for events is similar for both genders when stratified by CAC score, wherein a high CAC score carries a high risk for events despite normal SPECT MPI. Our findings do not reveal a gender-specific prognostic value of the CAC score.

  14. Clinical studies of cerebral circulation using single photon emission computed tomography, 2; Evaluation of cerebral blood flow after acetazolamide loading on moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Toshiro [Gifu Univ. (Japan). Faculty of Medicine

    1993-09-01

    To evaluate cerebral blood flow (CBF) in patients with moyamoya disease, single photon emission computed tomography (SPECT) was performed using acetazolamide-activated {sup 133}Xe inhalation method. In the present investigation, 15 patients were subjected: 6 pediatric cases with the mean age of 10.8 years and 9 adult cases with the mean age of 44.6 years. The regional CBF (rCBF) was measured in the territory of anterior cerebral artery (ACA), middle cerebral artery (MCA), posterior cerebral artery (PCA), basal ganglia, and cerebellum. Cerebrovascular acetazolamide reactivity was evaluated from the rCBF measured before and after administration of acetazolamide. Namely, cerebrovascular acetazolamide reactivity was expressed as %CBF and calculated as follows: %CBF=100 x (CBF after acetazolamide administration-CBF at rest)/CBF at rest. rCBF in adult patients was decreased in the cerebral hemisphere, while that in childhood was significantly decreased in the territory of ACA. The %CBF after acetazolamide loading was decreased in the territory of ACA and MCA in both adult and childhood. When cerebral %CBF was compared to the cerebellar %CBF, the ratio of cerebral %CBF and cerebellar %CBF resulted in markedly lower in childhood than adult. rCBF and cerebrovascular acetazolamide reactivity were also measured before and after extracranial and intracranial (EC-IC) bypass surgery in three pediatric moyamoya patients. Although rCBF was increased immediately after EC-IC bypass surgery, the cerebrovascular acetazolamide reactivity remained blunted. These results meant that in the pediatric moyamoya patients cerebrovascular acetazolamide reactivity is more blunted than adult moyamoya patients. Also, the cerebral vessels in moyamoya disease were considered to be dilated to their limitation by the blood supplied through the EC-IC bypass and not to be expandable any more by acetazolamide. (author) 45 refs.

  15. Non-invasive evaluation of myocardial reperfusion by transthoracic Doppler echocardiography and single-photon emission computed tomography in patients with anterior acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Celutkiene Jelena

    2011-05-01

    Full Text Available Abstract Background The study was designed to evaluate whether the preserved coronary flow reserve (CFR 72 hours after reperfused acute myocardial infarction (AMI is associated with less microvascular dysfunction and is predictive of left ventricular (LV functional recovery and the final infarct size at follow-up. Methods In our study, CFR was assessed by transthoracic Doppler echocardiography (TDE in 44 patients after the successful percutaneous coronary intervention during the acute AMI phase. CFR was correlated with contractile reserve assessed by low-dose dobutamine echocardiography and with the total perfusion defect measured by single-photon emission computed tomography 72 hours after reperfusion and at 5 months follow-up. The ROC analysis was performed to determine test sensitivity and specificity based on CFR. Categorical data were compared by an χ2 analysis, continuous variables were analysed with the independent Student's t test. In order to analyse correlation between CFR and the parameters of LV function and perfusion, the Pearson correlation analysis was conducted. The linear regression analysis was used to assess the relationship between CFR and myocardial contractility as well as the final infarct size. Results We estimated the CFR cut-off value of 1.75 as providing the maximal accuracy to distinguish between patients with preserved and impaired CFR during the acute AMI phase (sensitivity 91.7%, specificity 75%. Wall motion score index was better in the subgroup with preserved CFR as compared to the subgroup with reduced CFR: 1.74 (0.29 vs. 1.89 (0.17 (p Conclusion The early measurement of CFR by TDE can be of high value for the assessment of successful reperfusion in AMI and can be used to predict LV functional recovery, myocardial viability and the final infarct size.

  16. Single-photon decision maker

    CERN Document Server

    Naruse, Makoto; Drezet, Aurelien; Huant, Serge; Aono, Masashi; Hori, Hirokazu; Kim, Song-Ju

    2015-01-01

    Decision making is critical in our daily lives and for society in general and is finding evermore practical applications in information and communication technologies. Herein, we demonstrate experimentally that single photons can be used to make decisions in uncertain, dynamically changing environments. Using a nitrogen-vacancy in a nanodiamond as a single-photon source, we demonstrate the decision-making capability by solving the multi-armed bandit problem. This capability is directly and immediately associated with single-photon detection in the proposed architecture, leading to adequate and adaptive autonomous decision making. This study makes it possible to create systems that benefit from the quantum nature of light to perform practical and vital intelligent functions.

  17. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  18. Initial multicentre experience of high-speed myocardial perfusion imaging: comparison between high-speed and conventional single-photon emission computed tomography with angiographic validation

    Energy Technology Data Exchange (ETDEWEB)

    Neill, Johanne [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); The Prince Charles Hospital, Brisbane (Australia); Prvulovich, Elizabeth M.; Bomanji, Jamshed B. [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Fish, Matthews B. [Sacred Heart Medical Center (SHMC), Springfield, OR (United States); Berman, Daniel S.; Slomka, Piotr J. [Cedars-Sinai Medical Center, Los Angeles, CA (United States); Sharir, Tali [Procardia Maccabi Healthcare Services (PMHS), Tel Aviv (Israel); Martin, William H. [Vanderbilt University Medical Center (VUMC), Nashville, TN (United States); DiCarli, Marcelo F. [Brigham and Women' s Hospital (BWH), Boston, MA (United States); Ziffer, Jack A. [Baptist Hospital of Miami (BHM), Miami, FL (United States); Shiti, Dalia [Spectrum-Dynamics, Caesarea (Israel); Ben-Haim, Simona [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Chaim Sheba Medical Center, Department of Nuclear Medicine, Tel-Hashomer (Israel)

    2013-07-15

    High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS {>=}3 or coronary territorial SSS {>=}2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5 % and coronary territorial TPD {>=}3 % were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; {>=}50 % was considered significant. Of the 50 patients, 13 (26 %) had no stenosis, 22 (44 %) had single-vessel disease, 6 (12 %) had double-vessel disease and 9 (18 %) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's {rho} 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92 % (35/38), 83 % (10/12) and 90 % (45/50) vs. 84 % (32/38), 50 % (6/12) and 76 % (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89 % (31/35), 57 % (8/14) and 80 % (39/49) vs. 86 % (31/36), 77 % (10/13) and 84 % (41/49), respectively. HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual

  19. Longitudinal Evaluation of Sympathetic Nervous System and Perfusion in Normal and Spontaneously Hypertensive Rat Hearts with Dynamic Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yunlong Zan

    2015-07-01

    Full Text Available The objective of this work was to evaluate the sympathetic nervous system and structure remodeling during the progression of heart failure in a rodent model using dynamic cardiac single-photon emission computed tomography (SPECT. The spontaneously hypertensive rat (SHR model was used to study changes in the nervous system innervation and perfusion in the left ventricular (LV myocardium with the progression of left ventricular hypertrophy (LVH to heart failure. Longitudinal dynamic SPECT studies were performed with seven SHR and seven Wistar-Kyoto (WKY rats over 1.5 years using a dual-head SPECT scanner with pinhole collimators. Time-activity curves (TACs of the 123I-MIBG and 201Tl distribution in the LV blood pool and myocardium were extracted from dynamic SPECT data and fitted to compartment models to determine the influx rate, washout rate, and distribution volume (DV of 123I-MIBG and 201Tl in the LV myocardium. The standardized uptake values (SUVs of 123I-MIBG and 201Tl in the LV myocardium were also calculated from the static reconstructed images. The influx and washout rates of 123I-MIBG did not show a significant difference between SHRs and WKY rats. The DVs of 123I-MIBG were greater in the SHRs than in the WKY rats (p = .0028. Specifically, the DV of 123I-MIBG became greater in the SHRs by 6 months of age (p = .0017 and was still significant at the age of 22 months. The SUV of 123I-MIBG in SHRs exhibited abnormal values compared to WKY rats from the age of 18 months. There was no difference in the influx rate and the washout rate of 201Tl between the SHRs and WKY rats. The SHRs exhibited greater DV of 201Tl than WKY rats after the age of 18 months (p = .034. The SUV of 201Tl in SHRs did not show any significant difference from WKY at all ages. The higher DV of 123I-MIBG in the LV myocardium reveals abnormal nervous system activity of the SHRs at an age of 6 months, whereas a greater DV of 201Tl in the LV myocardium can only be detected at

  20. Dopamine transporter distribution in patients with Parkinson disease of different stages detected using single-photon emission computed tomography brain imaging

    Institute of Scientific and Technical Information of China (English)

    Jiwu Zhang; Lijuan Zhu; Jianqiang Du; Bo Liu

    2007-01-01

    BACKGROUND: Literatures have reported that the density changes of dopamine transporter is negatively correlated with the severity degree and grading of disease condition of Parkinson disease (PD). However, the distribution of dopamine transporter in each nucleus of corpora striatum at each period is still unclear.OBJECTIVE: To observe the radioactive uptake distribution of dopamine transporter in bilateral corpora striata of patients with different stages of PD using single photon emission computed tomography (SPECT),and make a comparison with healthy controls.DESIGN: Case-control analysis.SETTING: Department of Imageology, Second Hospital Affiliated to Guangzhou University of Chinese Medicine.PARTICIPANTS: Thirty patients with PD admitted to Second Hospital Affiliated to Guangzhou University of Traditional Chinese Medicine between January and December 2005 were recruited. The involved patients,19 male and 11 female, were aged from 36 to 80 years and with disease course of 2.5 months to 10 years.They all met the clinical diagnosis criteria of Britain Parkinson's disease Association Think Tank; Following Hoehn-Yahr grading: grade Ⅰ: unilateral morbidity; grade Ⅱ: bilateral morbidity, but without balance disorder; grade Ⅲ: bilateral morbidity, accompanied with early posture balance disorder; grade Ⅳ: severe morbidity, needs more help; grade Ⅴ: without help, only in bed or wheelchair. There were 11 patients with mild PD (grade Ⅰ - Ⅱ ), 9 patients with moderate PD (grade Ⅲ) and 10 patients with advanced PD (grade Ⅳ -V). Meanwhile, 6 healthy persons were selected as normal controls. Informed consents were obtained from all the subjects.METHODS: Twenty-four hours after withdrawal of PD drugs, 30 patients with PD and 6 healthy controls took kalium perchloricum 400 mg orally. After lying down for 30 minutes, all the subjects were intravenously injected with 740 MBq 99Tc m-TRODAT-1 (Jiangsu Institute of Atomic Medicine, Batch No.20040310) at elbow part

  1. Analysis of regional cerebral blood flow and distribution volume in Machado-Joseph disease by iodine-{sup 123}I IMP single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Tsunemi; Nakajima, Takashi; Fukuhara, Nobuyoshi [National Saigata Hospital, Ohagata, Niigata (Japan)

    2001-09-01

    Machado-Joseph disease (MJD) is an autosomal dominant spinocerebellar ataxia. Its clinical features vary greatly in different generations of the same family. Regional cerebral blood flow (rCBF) and distribution volume (V{sub d}) in the pons, cerebellum, and cerebral cortex were measured in 12 patients with MJD by autoradiography (ARG) and the table look-up (TLU) method of iodine-123 IMP ({sup 123}I-IMP) single photon emission computed tomography (SPECT). Representative cases were as follows: A 46-year-old woman first experienced gait ataxia at age 38. Computed tomography (CT) and magnetic resonance imaging (MRI) showed no atrophy in the pons or cerebellum, but rCBF measured by the {sup 123}I-IMP SPECT ARG method detected hypoperfusion in the pons, and cerebellar vermis and hemisphere. A 76-year-old woman first experienced gait ataxia at age 69. CT and MRI findings showed severe atrophy in the pons, and cerebellar vermis and hemisphere. Moreover, rCBF was decreased in the pons, whereas it was not decreased in the cerebellar vermis and hemisphere. In the pons of patients with MJD, rCBF was markedly decreased regardless of disease severity. Because this SPECT finding for the pons looked like a 'dot', we have called it the 'pontine dot sign'. In the MJD group, rCBF was significantly decreased in the pons (Student's t test, p<0.01) and cerebellar vermis (p<0.05). The V{sub d} was also significantly decreased in the pons (p<0.005) in comparison with that for normal subjects. Pearson's correlation analysis yielded a significant relationship between the rCBF in the pons and age at onset (r=0.578, p<0.05). There was a strong correlation between the V{sub d} for the pons and age at onset (r=0.59, p<0.05). Person's correlation analysis also showed a significant relationship between the V{sub d} in the cerebellar hemispheres and International Cooperative Ataxia Rating Scale (r=0.644, p<0.05). The pontine rCBFs in patients with early onset MJD

  2. Extraction of a single photon from an optical pulse

    Science.gov (United States)

    Rosenblum, Serge; Bechler, Orel; Shomroni, Itay; Lovsky, Yulia; Guendelman, Gabriel; Dayan, Barak

    2016-01-01

    Removing a single photon from a pulse is one of the most elementary operations that can be performed on light, having both fundamental significance and practical applications in quantum communication and computation. So far, photon subtraction, in which the removed photon is detected and therefore irreversibly lost, has been implemented in a probabilistic manner with inherently low success rates using low-reflectivity beam splitters. Here we demonstrate a scheme for the deterministic extraction of a single photon from an incoming pulse. The removed photon is diverted to a different mode, enabling its use for other purposes, such as a photon number-splitting attack on quantum key distribution protocols. Our implementation makes use of single-photon Raman interaction (SPRINT) with a single atom near a nanofibre-coupled microresonator. The single-photon extraction probability in our current realization is limited mostly by linear loss, yet probabilities close to unity should be attainable with realistic experimental parameters.

  3. Ramsey Interference with Single Photons

    Science.gov (United States)

    Clemmen, Stéphane; Farsi, Alessandro; Ramelow, Sven; Gaeta, Alexander L.

    2016-11-01

    Interferometry using discrete energy levels of nuclear, atomic, or molecular systems is the foundation for a wide range of physical phenomena and enables powerful techniques such as nuclear magnetic resonance, electron spin resonance, Ramsey-based spectroscopy, and laser or maser technology. It also plays a unique role in quantum information processing as qubits may be implemented as energy superposition states of simple quantum systems. Here, we demonstrate quantum interference involving energy states of single quanta of light. In full analogy to the energy levels of atoms or nuclear spins, we implement a Ramsey interferometer with single photons. We experimentally generate energy superposition states of a single photon and manipulate them with unitary transformations to realize arbitrary projective measurements. Our approach opens the path for frequency-encoded photonic qubits in quantum information processing and quantum communication.

  4. Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography

    Directory of Open Access Journals (Sweden)

    Kamaleshwaran Koramadai Karuppusamy

    2015-01-01

    Full Text Available High doses of iodine-131 are commonly used in patients with differentiated thyroid cancer after total or subtotal thyroidectomy, in order to ablate the remaining cancer or normal thyroid tissue. Multiple different false-positive scans can occur in the absence of residual thyroid tissue or metastases. The authors present a case of abnormal uptake of radioactive iodine in the aspergilloma, potentially masquerading as pulmonary metastases.

  5. Quantification of Tc-99m-ethyl cysteinate dimer brain single photon emission computed tomography images using statistical probabilistic brain atlas in depressive end-stage renal disease patients Correlation with disease severity and symptom factors

    Institute of Scientific and Technical Information of China (English)

    Heeyoung Kim; In Joo Kim; Seong-Jang Kim; Sang Heon Song; Kyoungjune Pak; Keunyoung Kim

    2012-01-01

    This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the relationship between symptom clusters, disease severity, and cerebral blood flow. Twenty-seven patients (16 males, 11 females) with stages 4 and 5 end-stage renal disease were enrolled, along with 25 healthy controls. All patients underwent depressive mood assessment and brain single photon emission computed tomography. The statistical probabilistic anatomical map images were used to calculate the brain single photon emission computed tomography counts. Asymmetric index was acquired and Pearson correlation analysis was performed to analyze the correlation between symptom factors, severity, and regional cerebral blood flow. The depression factors of the Hamilton Depression Rating Scale showed a negative correlation with cerebral blood flow in the left amygdale. The insomnia factor showed negative correlations with cerebral blood flow in the left amygdala, right superior frontal gyrus, right middle frontal gyrus, and left middle frontal gyrus. The anxiety factor showed a positive correlation with cerebral glucose metabolism in the cerebellar vermis and a negative correlation with cerebral glucose metabolism in the left globus pallidus, right inferior frontal gyrus, both temporal poles, and left parahippocampus. The overall depression severity (total scores of Hamilton Depression Rating Scale) was negatively correlated with the statistical probabilistic anatomical map results in the left amygdala and right inferior frontal gyrus. In conclusion, our results demonstrated that the disease severity and extent of cerebral blood flow quantified by a probabilistic brain atlas was related to various brain areas in terms of the overall severity and symptom factors in end-stage renal disease patients.

  6. Diagnostic performance of exercise bicycle testing and single-photon emission computed tomography: Comparison with 64-slice computed tomography coronary angiography

    NARCIS (Netherlands)

    A.C. Weustink (Annick); L.A.E. Neefjes (Lisan); A. Rossi (Alexia); W.B. Meijboom (Willem Bob); K. Nieman (Koen); E. Capuano (Ermanno); H. Boersma (Eric); N.R.A. Mollet (Nico); G.P. Krestin (Gabriel); P.J. de Feyter (Pim)

    2012-01-01

    textabstractTo conduct a comparison of the diagnostic performance of exercise bicycle testing and singlephoton emission computed tomography (SPECT) with computed tomography coronary angiography (CTCA) for the detection of obstructive coronary artery disease (CAD) in patients with stable angina. 376

  7. Imaging by single photon emission computed tomography: interest in the pre surgical check up of epilepsy; L'imagerie par tomographie d'emission monophotonique: interet dans le bilan pre-chirurgical de l'epilepsie

    Energy Technology Data Exchange (ETDEWEB)

    Biraben, A. [UPRES EA 2232, Cortex Cerebral et epilepsie, 35 - Rennes (France); Bernard, A.M. [Centre Eugene-Marquis, 35 - Rennes (France)

    1999-12-01

    With the single photon emission computed tomography, it is a more reliable technique that is at someone's disposal, especially to limit spatially the evolution of epilepsy crisis before any surgery act. The determination of the precise area is necessary to make sure that the crisis come really from this area and the determination of the functionality of this area is checked to be sure that the ablation of the zone will not lead to an unacceptable functional deficit. (N.C.)

  8. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  9. Single photon emission computed tomography with [sup 123]I-N-isopropyl-p-iodoamphetamine in three cases of neuroleptic malignant syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Nishijima, Koichi; Matoba, Masaki; Takano, Kenji; Ishiguro, Takeo (Jichi Medical School, Minamikawachi, Tochigi (Japan)); Nakamura, Megumi; Nagano, Mitsuru

    1992-11-01

    Three patients with neuroleptic malignant syndrome underwent single photon emission computd tomography (SPECT) with I-123-N-isopropyl-p-iodoamphetamine (I-123 IMP). In two patients, there was bilateral difference in tracer uptake on early images: decreased uptake in the right basal ganglion and increased uptake in the left basal ganglion. In the third patient, similar findings were seen on early images; however, in contrast to early images, delayed images showed more noticeable tracer uptake in the right basal ganglion than the left basal ganglion. These findings were not associated with the recovery from neuroleptic malignant syndrome. This suggested that some abnormality in the basal ganglion may be involved in the occurrence of neuroleptic malignant syndrome. SPECT with I-123 IMP was considered useful in searching for pathophysiology of neuroleptic malignant syndrome. (N.K.).

  10. Better Randomness with Single Photons

    CERN Document Server

    Oberreiter, Lukas

    2014-01-01

    Randomness is one of the most important resources in modern information science, since encryption founds upon the trust in random numbers. Since it is impossible to prove if an existing random bit string is truly random, it is relevant that they be generated in a trust worthy process. This requires specialized hardware for random numbers, for example a die or a tossed coin. But when all input parameters are known, their outcome might still be predicted. A quantum mechanical superposition allows for provably true random bit generation. In the past decade many quantum random number generators (QRNGs) were realized. A photonic implementation is described as a photon which impinges on a beam splitter, but such a protocol is rarely realized with non-classical light or anti-bunched single photons. Instead, laser sources or light emitting diodes are used. Here we analyze the difference in generating a true random bit string with a laser and with anti-bunched light. We show that a single photon source provides more r...

  11. Single photon emission computed tomography of the brain in Sturge-Weber syndrome using N-isopropyl-p-( sup 123 I) iodoamphetamine; A comparative study with X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Horita, Hideki; Nozaki, Hidetsugu; Hamano, Shinichiro; Aihara, Toshinori (Saitama Children' s Medical Center, Iwatsuki (Japan))

    1990-07-01

    Single photon emission computed tomography (SPECT) of the brain using N-isopropyl-p-({sup 123}I) iodoamphetamine ({sup 123}I-IMP) was performed in 11 children with port wine stain on the face or head, aged 1.0{approx}14.2 years at investigation. Four cases without neurologic symptoms had no specific abnormality on SPECT and X-ray computed tomography (CT). In 4 cases of so-called Sturge-Weber syndrome with developmental quotients (DQ) or intelligence quotients (IQ) more than 80 and the neurologic symptoms consisting of seizures and hemiplegia, SPECT showed localized reduction of IMP accumulation, and CT exhibited calcification, atrophy and enhancement in 2 cases of 3 with contrast medium infusion in the same areas. In 3 cases with DQ of 50{approx}60 and severer neurologic symptoms, SPECT showed diffuse reduction or defect of IMP accumulation in the ipsilateral hemisphere, and CT exhibited remarkable atrophy, calcifications and enhancement in 2 cases with contrast medium infusion in the same hemisphere. In one case with severe neurologic symptoms, SPECT performed at an early stage showed high IMP accumulation in the ipsilateral hemisphere. (author).

  12. MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

    Science.gov (United States)

    Accorsi, R.; Autiero, M.; Celentano, L.; Chmeissani, M.; Cozzolino, R.; Curion, A. S.; Frallicciardi, P.; Laccetti, P.; Lanza, R. C.; Lauria, A.; Maiorino, M.; Marotta, M.; Mettivier, G.; Montesi, M. C.; Riccio, P.; Roberti, G.; Russo, P.

    2007-02-01

    We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256×256 matrix of 55 μm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. 125I, 27-35 keV, 99mTc, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 μm at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29 mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140 keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor.

  13. Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, L.L.; Lerrick, K.S.; Coromilas, J.; Seldin, D.W.; Esser, P.D.; Zimmerman, J.M.; Keller, A.M.; Alderson, P.O.; Bigger, J.T. Jr.; Cannon, P.J.

    1987-07-01

    Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous injection of labeled Fab fragments with the use of a dual-head SPECT camera with medium-energy collimators. Immediately after the first tomographic scan, thallium-201 was injected into nine of 12 dogs and imaging was repeated. Estimated infarct size in grams was calculated from transaxially reconstructed, normalized, and background-corrected indium SPECT images with the use of a threshold technique for edge detection. Estimated noninfarcted myocardium in grams was calculated from obliquely reconstructed thallium SPECT images by a similar method. The animals were killed and infarct size in grams and true infarct size as a percentage of total left ventricular myocardial volume were measured by triphenyl tetrazolium chloride staining. Estimated infarct size from indium SPECT images showed an excellent correlation with true infarct size (r = .95, SEE = 4.1 g). Estimated percentage myocardium infarcted was calculated by dividing estimated infarct size from indium images by the sum of estimated infarct size plus estimated noninfarcted myocardium obtained from thallium images. Correlation between the estimated percentage of myocardium infarcted and true percentage of myocardium infarcted was excellent.

  14. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia; Apport de la tomographie d'emission monophonique cerebrale dans l'evaluation des demences de type Alzheimer

    Energy Technology Data Exchange (ETDEWEB)

    Boudousq, V.; Collombier, L.; Kotzki, P.O. [Centre Hospitalier Universitaire de Nimes, 30 (France)

    1999-12-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  15. The Single-Photon Router

    CERN Document Server

    Hoi, Io-Chun; Johansson, Göran; Palomaki, Tauno; Peropadre, Borja; Delsing, Per

    2011-01-01

    We have embedded an artificial atom, a superconducting "transmon" qubit, in an open transmission line and investigated the strong scattering of incident microwave photons ($\\sim6$ GHz). When an input coherent state, with an average photon number $N\\ll1$ is on resonance with the artificial atom, we observe extinction of up to 90% in the forward propagating field. We use two-tone spectroscopy to study scattering from excited states and we observe electromagnetically induced transparency (EIT). We then use EIT to make a single-photon router, where we can control to what output port an incoming signal is delivered. The maximum on-off ratio is around 90% with a rise and fall time on the order of nanoseconds, consistent with theoretical expectations. The router can easily be extended to have multiple output ports and it can be viewed as a rudimentary quantum node, an important step towards building quantum information networks.

  16. A solid-state single-photon filter

    Science.gov (United States)

    de Santis, Lorenzo; Antón, Carlos; Reznychenko, Bogdan; Somaschi, Niccolo; Coppola, Guillaume; Senellart, Jean; Gómez, Carmen; Lemaître, Aristide; Sagnes, Isabelle; White, Andrew G.; Lanco, Loïc; Auffèves, Alexia; Senellart, Pascale

    2017-07-01

    A strong limitation of linear optical quantum computing is the probabilistic operation of two-quantum-bit gates based on the coalescence of indistinguishable photons. A route to deterministic operation is to exploit the single-photon nonlinearity of an atomic transition. Through engineering of the atom-photon interaction, phase shifters, photon filters and photon-photon gates have been demonstrated with natural atoms. Proofs of concept have been reported with semiconductor quantum dots, yet limited by inefficient atom-photon interfaces and dephasing. Here, we report a highly efficient single-photon filter based on a large optical nonlinearity at the single-photon level, in a near-optimal quantum-dot cavity interface. When probed with coherent light wavepackets, the device shows a record nonlinearity threshold around 0.3 ± 0.1 incident photons. We demonstrate that 80% of the directly reflected light intensity consists of a single-photon Fock state and that the two- and three-photon components are strongly suppressed compared with the single-photon one.

  17. Highly efficient heralding of entangled single photons.

    Science.gov (United States)

    Ramelow, Sven; Mech, Alexandra; Giustina, Marissa; Gröblacher, Simon; Wieczorek, Witlef; Beyer, Jörn; Lita, Adriana; Calkins, Brice; Gerrits, Thomas; Nam, Sae Woo; Zeilinger, Anton; Ursin, Rupert

    2013-03-25

    Single photons are an important prerequisite for a broad spectrum of quantum optical applications. We experimentally demonstrate a heralded single-photon source based on spontaneous parametric down-conversion in collinear bulk optics, and fiber-coupled bolometric transition-edge sensors. Without correcting for background, losses, or detection inefficiencies, we measure an overall heralding efficiency of 83%. By violating a Bell inequality, we confirm the single-photon character and high-quality entanglement of our heralded single photons which, in combination with the high heralding efficiency, are a necessary ingredient for advanced quantum communication protocols such as one-sided device-independent quantum key distribution.

  18. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  19. Graphene-Based Josephson-Junction Single-Photon Detector

    Science.gov (United States)

    Walsh, Evan D.; Efetov, Dmitri K.; Lee, Gil-Ho; Heuck, Mikkel; Crossno, Jesse; Ohki, Thomas A.; Kim, Philip; Englund, Dirk; Fong, Kin Chung

    2017-08-01

    We propose to use graphene-based Josephson junctions (GJJs) to detect single photons in a wide electromagnetic spectrum from visible to radio frequencies. Our approach takes advantage of the exceptionally low electronic heat capacity of monolayer graphene and its constricted thermal conductance to its phonon degrees of freedom. Such a system could provide high-sensitivity photon detection required for research areas including quantum information processing and radio astronomy. As an example, we present our device concepts for GJJ single-photon detectors in both the microwave and infrared regimes. The dark count rate and intrinsic quantum efficiency are computed based on parameters from a measured GJJ, demonstrating feasibility within existing technologies.

  20. CMOS-compatible photonic devices for single-photon generation

    Science.gov (United States)

    Xiong, Chunle; Bell, Bryn; Eggleton, Benjamin J.

    2016-09-01

    Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal-oxide-semiconductor (CMOS)-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon) and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  1. Superconducting single photon detectors integrated with diamond nanophotonic circuits

    CERN Document Server

    Rath, Patrik; Ferrari, Simone; Sproll, Fabian; Lewes-Malandrakis, Georgia; Brink, Dietmar; Ilin, Konstantin; Siegel, Michael; Nebel, Christoph; Pernice, Wolfram

    2015-01-01

    Photonic quantum technologies promise to repeat the success of integrated nanophotonic circuits in non-classical applications. Using linear optical elements, quantum optical computations can be performed with integrated optical circuits and thus allow for overcoming existing limitations in terms of scalability. Besides passive optical devices for realizing photonic quantum gates, active elements such as single photon sources and single photon detectors are essential ingredients for future optical quantum circuits. Material systems which allow for the monolithic integration of all components are particularly attractive, including III-V semiconductors, silicon and also diamond. Here we demonstrate nanophotonic integrated circuits made from high quality polycrystalline diamond thin films in combination with on-chip single photon detectors. Using superconducting nanowires coupled evanescently to travelling waves we achieve high detection efficiencies up to 66 % combined with low dark count rates and timing resolu...

  2. Quantum teleportation with a quantum dot single photon source.

    Science.gov (United States)

    Fattal, D; Diamanti, E; Inoue, K; Yamamoto, Y

    2004-01-23

    We report the experimental demonstration of a quantum teleportation protocol with a semiconductor single photon source. Two qubits, a target and an ancilla, each defined by a single photon occupying two optical modes (dual-rail qubit), were generated independently by the single photon source. Upon measurement of two modes from different qubits and postselection, the state of the two remaining modes was found to reproduce the state of the target qubit. In particular, the coherence between the target qubit modes was transferred to the output modes to a large extent. The observed fidelity is 80%, in agreement with the residual distinguishability between consecutive photons from the source. An improved version of this teleportation scheme using more ancillas is the building block of the recent Knill, Laflamme, and Milburn proposal for efficient linear optics quantum computation.

  3. Integrated spatial multiplexing of heralded single photon sources

    CERN Document Server

    Collins, Matthew J; Rey, Isabella H; Vo, Trung D; He, Jiakun; Shahnia, Shayan; Reardon, Christopher; Steel, M J; Krauss, Thomas F; Clark, Alex S; Eggleton, Benjamin J

    2013-01-01

    The non-deterministic nature of photon sources is a key limitation for single photon quantum processors. Spatial multiplexing overcomes this by enhancing the heralded single photon yield without enhancing the output noise. Here the intrinsic statistical limit of an individual source is surpassed by spatially multiplexing two monolithic silicon correlated photon pair sources, demonstrating a 62.4% increase in the heralded single photon output without an increase in unwanted multi-pair generation. We further demonstrate the scalability of this scheme by multiplexing photons generated in two waveguides pumped via an integrated coupler with a 63.1% increase in the heralded photon rate. This demonstration paves the way for a scalable architecture for multiplexing many photon sources in a compact integrated platform and achieving efficient two photon interference, required at the core of optical quantum computing and quantum communication protocols.

  4. Single-photon indistinguishability: influence of phonons

    DEFF Research Database (Denmark)

    Nielsen, Per Kær; Lodahl, Peter; Jauho, Antti-Pekka

    2012-01-01

    effects is important in linear optical quantum computing [1], where a device emitting fully coherent indistinguishable single photons on demand, is the essential ingredient. In this contribution we present a numerically exact simulation of the effect of phonons on the degree of indistinguishability......Recent years have demonstrated that the interaction with phonons plays an important role in semiconductor based cavity QED systems [2], consisting of a quantum dot (QD) coupled to a single cavity mode [Fig. 1(a)], where the phonon interaction is the main decoherence mechanism. Avoiding decoherence...... of photons emitted from a solid-state cavity QED system. Our model rigorously describes non-Markovian effects to all orders in the phonon coupling constant, being based on an exact diagonalization procedure accounting for the time evoluiton of one-time and two-time photon correlation funcitons. We compare...

  5. A Pilot Study Measuring the Distribution and Permeability of a Vaginal HIV Microbicide Gel Vehicle Using Magnetic Resonance Imaging, Single Photon Emission Computed Tomography/Computed Tomography, and a Radiolabeled Small Molecule.

    Science.gov (United States)

    Fuchs, Edward J; Schwartz, Jill L; Friend, David R; Coleman, Jenell S; Hendrix, Craig W

    2015-11-01

    Vaginal microbicide gels containing tenofovir have proven effective in HIV prevention, offering the advantage of reduced systemic toxicity. We studied the vaginal distribution and effect on mucosal permeability of a gel vehicle. Six premenopausal women were enrolled. In Phase 1, a spreading gel containing (99m)technetium-DTPA ((99m)Tc) radiolabel and gadolinium contrast for magnetic resonance imaging (MRI) was dosed intravaginally. MRI was obtained at 0.5, 4, and 24 h, and single photon emission computed tomography with conventional computed tomography (SPECT/CT) at 1.5, 5, and 25 h postdosing. Pads and tissues were measured for activity to determine gel loss. In Phase 2, nonoxynol-9 (N-9), containing (99m)Tc-DTPA, was dosed as a permeability control; permeability was measured in blood and urine for both phases. SPECT/CT showed the distribution of spreading gel throughout the vagina with the highest concentration of radiosignal in the fornices and ectocervix; signal intensity diminished over 25 h. MRI showed the greatest signal accumulation in the fornices, most notably 1-4 h postdosing. The median (interquartile range) isotope signal loss from the vagina through 6 h was 29.1% (15.8-39.9%). Mucosal permeability to (99m)Tc-DTPA following spreading gel was negligible, in contrast to N-9, with detectable radiosignal in plasma, peaking at 8 h (5-12). Following spreading gel dosing, 0.004% (0.001-2.04%) of the radiosignal accumulated in urine over 12 h compared to 8.31% (7.07-11.01%) with N-9, (p=0.043). Spreading gel distributed variably throughout the vagina, persisting for 24 h, with signal concentrating in the fornices and ectocervix. The spreading gel had no significant effect on vaginal mucosal permeability.

  6. Bone and Gallium Single-Photon Emission Computed Tomography-Computed Tomography is Equivalent to Magnetic Resonance Imaging in the Diagnosis of Infectious Spondylodiscitis: A Retrospective Study.

    Science.gov (United States)

    Tamm, Alexander S; Abele, Jonathan T

    2017-02-01

    Spondylodiscitis has historically been a difficult clinical diagnosis. Two imaging techniques that address this problem are magnetic resonance imaging (MRI) and combined bone ((99m)Tc-methylene diphosphonate) and gallium-67 single-photon emission computed tomography-computed tomography (SPECT-CT). Their accuracies have not been adequately compared. The purpose of this study is to compare the sensitivities and specificities of bone and gallium SPECT-CT and MRI in infectious spondylodiscitis. This retrospective study assessed all patients who underwent a bone or gallium SPECT-CT of the spine to assess for infectious spondylodiscitis from January 1, 2010, to May 2, 2012, at a single tertiary care centre. Thirty-four patients (23 men; average 62 ± 14 years of age) were included. The results of the bone or gallium SPECT-CT were compared against MRI for all patients in the cohort who underwent an MRI within 12 weeks of the SPECT-CT. A diagnosis of spondylodiscitis in the discharge summary was considered the reference standard, and was based on a combination of clinical scenario, response to therapy, imaging, or microbiology. Spondylodiscitis was diagnosed in 18 patients and excluded in 16. Bone or gallium SPECT-CT and MRI had similar (P > .05; κ = 0.74) sensitivities (0.94 vs 0.94), specificities (1.00 vs 1.00), positive predictive values (1.00 vs 1.00), negative predictive values (0.94 vs 0.80), and accuracies (0.97 vs 0.95) when compared to the reference standard. Although MRI remains the initial modality of choice in diagnosing spondylodiscitis, bone and gallium SPECT-CT appears diagnostically equivalent and should be considered a viable supplementary or alternative imaging modality particularly if there is contraindication or inaccessibility to MRI. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Hiding Single Photons With Spread Spectrum Technology

    CERN Document Server

    Belthangady, Chinmay; Yu, Ite A; Yin, G Y; Kahn, J M; Harris, S E

    2010-01-01

    We describe a proof-of-principal experiment demonstrating the use of spread spectrum technology at the single photon level. We show how single photons with a prescribed temporal shape, in the presence of interfering noise, may be hidden and recovered.

  8. Single-photon source characterization with infrared-sensitive superconducting single-photon detectors

    CERN Document Server

    Hadfield, R H; Nam, S W; Stevens, M J; Hadfield, Robert H.; Mirin, Richard P.; Nam, Sae Woo; Stevens, Martin J.

    2006-01-01

    Single-photon sources and detectors are key enabling technologies in quantum information processing. Nanowire-based superconducting single-photon detectors (SSPDs) offer single-photon detection from the visible well into the infrared with low dark counts, low jitter and short dead times. We report on the high fidelity characterization (via antibunching and spontaneous emission lifetime measurements) of a cavity-coupled single-photon source at 902 nm using a pair of SSPDs. The twin SSPD scheme reported here is well-suited to the characterization of single-photon sources at telecom wavelengths (1310 nm, 1550 nm).

  9. Integrated optomechanical single-photon frequency shifter

    Science.gov (United States)

    Fan, Linran; Zou, Chang-Ling; Poot, Menno; Cheng, Risheng; Guo, Xiang; Han, Xu; Tang, Hong X.

    2016-12-01

    The ability to manipulate single photons is of critical importance for fundamental quantum optics studies and practical implementations of quantum communications. While extraordinary progresses have been made in controlling spatial, temporal, spin and orbit angular momentum degrees of freedom, frequency-domain control of single photons so far relies on nonlinear optical effects, which have faced obstacles such as noise photons, narrow bandwidth and demanding optical filtering. Here, we demonstrate the first integrated optomechanical single-photon frequency shifter with near-unity efficiency. A frequency shift up to 150 GHz at telecom wavelength is realized without measurable added noise and the preservation of quantum coherence is verified through quantum interference between twin photons of different colours. This single-photon frequency shifter will be invaluable for increasing the channel capacity of quantum communications and compensating frequency mismatch between quantum systems, paving the road towards a hybrid quantum network.

  10. Single-photon detection, truth, and misinterpretation

    Science.gov (United States)

    Berloffa, E. H.

    2013-10-01

    Within this investigation it is critically questioned, if we really can detect "single photons", respectively the response of a single quantum transition by use of modern photon detectors. In the course it is shown that avalanche photodiodes (AVDs) especially in the "Geiger" mode by virtue of its geometry (effective area) indeed can detect "single photon" events as proclaimed by the manufacturers, but they tacitly assume the bandwidth of originating visible source being not greater than ~ 2.107 [Hz]. A short excurse to solid state basic physics makes it obvious applying the adequate doping accomplishes "single photon detection". Nevertheless this does not mean there is a 1:1 correspondence between a photon emanated from the source location and that detected within the detector module. Propagation characteristics were simply overlooked during the numerous discussions about "single photon" detection. Practical examples are worked out on hand of a pin- / and a AVDphotodiode.

  11. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Energy Technology Data Exchange (ETDEWEB)

    Razali, Azhani Mohd, E-mail: azhani@nuclearmalaysia.gov.my; Abdullah, Jaafar, E-mail: jaafar@nuclearmalaysia.gov.my [Plant Assessment Technology (PAT) Group, Industrial Technology Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang (Malaysia)

    2015-04-29

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  12. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Science.gov (United States)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-04-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  13. Stroing single-photons in microcavities arrays

    Science.gov (United States)

    Mirza, Imran M.; Enk, S. J. Van; Kimble, H. J.

    2014-03-01

    Coupling light to arrays of microcavities is one of the most promising avenues to store/delay classical light pulses [F. Krauss, Nat. Phot. 2, 448-450 (2008)]. However, from the perspective of benefiting quantum communication protocols, the same ideas in principle can be extended down to the single-photon (quantum) level as well. Particularly, for the purposes of entanglement purification and quantum repeaters a reliable storage of single photons is needed. We consider in our work [I. M. Mirza, S. Van Enk, H. Kimble JOSA B, 30,10 (2013)] cavities that are coupled through an optical fiber which is assumed to be forming a Markovian bath. For this study two powerful open quantum system techniques, Input-Output theory for cascaded quantum systems and the Quantum Trajectory approach are used in combination. For the confirmation of photon delays the Time-Dependent Spectrum of such a single photon is obtained. Interestingly this leads to a hole-burning effect showing that only certain frequency components in the single photon wavepackets are stored inside the cavities and hence are delayed in time. Since on-demand production of single photons is not an easy task we include in our description the actual generation of the single photon by assuming a single emitter in one the resonators.

  14. Novel [99mTcN]2+ Labeled EGFR Inhibitors as Potential Radiotracers for Single Photon Emission Computed Tomography (SPECT Tumor Imaging

    Directory of Open Access Journals (Sweden)

    Mingxia Zhao

    2014-04-01

    Full Text Available The epidermal growth factor receptor (EGFR is overexpressed in many cancers, including breast, ovarian, endometrial and non-small cell lung cancer. An EGFR-specific imaging agent could facilitate clinical evaluation of primary tumors or metastases. To achieve this goal, 4-(2-aminoethylamino-6,7-dimethoxyquinazoline (ADMQ was synthesized based on a 4-aminoquinazoline core and then conjugated with N-mercapto- acetylglycine (MAG and N-mercaptoacetyltriglycine (MAG3, respectively, to give compounds 1 and 2. The final complexes [99mTcN]-1 and [99mTcN]-2 were successfully obtained with radiochemical purities of >99% and >98% as measured by radio-HPLC. No decomposition of the two complexes at room temperature was observed over a period of 2 h. Their partition coefficients indicated they were hydrophilic and the electrophoresis results showed they were negatively charged. Biodistribution in tumor-bearing mice demonstrated that the two new complexes showed tumor accumulation, high tumor-tomuscle (T/M ratios and fast clearance from blood and muscle. Between the two compounds, the 99mTcN-MAG3-ADMQ ([99mTcN]-2 showed the better characteristics, with the tumor/muscle and tumor/blood ratios reached 2.11 and 1.90 at 60 min post-injection, 4.20 and 1.10 at 120 min post-injection, suggesting it could be a promising radiotracer for SPECT tumor imaging.

  15. Optimization of pinhole single photon emission computed tomography (pinhole SPECT) reconstruction; Optimisation de la reconstruction en tomographie d'emission monophotonique avec colimateur stenope

    Energy Technology Data Exchange (ETDEWEB)

    Israel-Jost, V

    2006-11-15

    In SPECT small animal imaging, it is highly recommended to accurately model the response of the detector in order to improve the low spatial resolution. The volume to reconstruct is thus obtained both by back-projecting and de-convolving the projections. We chose iterative methods, which permit one to solve the inverse problem independently from the model's complexity. We describe in this work a Gaussian model of point spread function (PSF) whose position, width and maximum are computed according to physical and geometrical parameters. Then we use the rotation symmetry to replace the computation of P projection operators, each one corresponding to one position of the detector around the object, by the computation of only one of them. This is achieved by choosing an appropriate polar discretization, for which we control the angular density of voxels to avoid over-sampling the center of the field of view. Finally, we propose a new family of algorithms, the so-called frequency adapted algorithms, which enable to optimize the reconstruction of a given band in the frequency domain on both the speed of convergence and the quality of the image. (author)

  16. Direct fiber-coupled single photon source based on a photonic crystal waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong-Hyeon, E-mail: seygene@kaist.ac.kr; Lee, Chang-Min; Lim, Hee-Jin [Department of Physics, KAIST, Daejeon 305-701 (Korea, Republic of); Schlereth, Thomas W.; Kamp, Martin [Technische Physik, Physikalisches Institut and Wilhelm Conrad Röntgen-Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); Höfling, Sven [Technische Physik, Physikalisches Institut and Wilhelm Conrad Röntgen-Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); SUPA, School of Physics and Astronomy, University of St. Andrews, St. Andrews KY16 9SS (United Kingdom); Lee, Yong-Hee [Department of Physics, KAIST, Daejeon 305-701 (Korea, Republic of); Graduate School of Nanoscience and Technology (WCU), KAIST, Daejeon 305-701 (Korea, Republic of)

    2015-08-24

    A single photon source plays a key role in quantum applications such as quantum computers and quantum communications. Epitaxially grown quantum dots are one of the promising platforms to implement a good single photon source. However, it is challenging to realize an efficient single photon source based on semiconductor materials due to their high refractive index. Here we demonstrate a direct fiber coupled single photon source with high collection efficiency by employing a photonic crystal (PhC) waveguide and a tapered micro-fiber. To confirm the single photon nature, the second-order correlation function g{sup (2)}(τ) is measured with a Hanbury Brown-Twiss setup. The measured g{sup (2)}(0) value is 0.15, and we can estimate 24% direct collection efficiency from a quantum dot to the fiber.

  17. Real-Time Three-Dimensional Echocardiography as a Novel Approach to Quantify Left Ventricular Dyssynchrony: A Comparison Study with Phase Analysis of Gated Myocardial Perfusion Single Photon Emission Computed Tomography

    Science.gov (United States)

    Marsan, Nina Ajmone; Henneman, Maureen M.; Chen, Ji; Ypenburg, Claudia; Dibbets, Petra; Ghio, Stefano; Bleeker, Gabe B.; Stokkel, Marcel P.; van der Wall, Ernst E.; Tavazzi, Luigi; Garcia, Ernest V.; Bax, Jeroen J.

    2010-01-01

    Background Different imaging modalities have been explored for assessment of left ventricular (LV) dyssynchrony. Gated myocardial perfusion single photon emission computed tomography (GMPS) with phase analysis is a reliable technique to quantify LV dyssynchrony and predict response to cardiac resynchronization therapy. Objective Real-time 3-dimensional echocardiography (RT3DE) is a novel imaging technique that provides a LV systolic dyssynchrony index, based on regional volumetric changes as a function of time and calculated as the SD of time to minimum systolic volume of 16 standard myocardial segments expressed in percentage of cardiac cycle. The aim of this study was to compare LV dyssynchrony evaluated with GMPS with LV dyssynchrony assessed with RT3DE. Methods The study population consisted of 40 patients with heart failure who underwent both GMPS and RT3DE. Results Good correlations between LV dyssynchrony assessed with RT3DE and GMPS were demonstrated (r = 0.76 for histogram bandwidth, r = 0.80 for phase SD, P < .0001). Patients with substantial LV dyssynchrony on GMPS (defined as ≥135 degrees for histogram bandwidth and ≥43 degrees for phase SD) had significantly higher LV systolic dyssynchrony index than patients without substantial LV dyssynchrony. Conclusions The good correlations between LV dyssynchrony assessed with GMPS and with RT3DE provide further support for the use of RT3DE for reliable assessment of LV dyssynchrony. PMID:18222645

  18. Use of a tantalum-178 generator and a multiwire gamma camera to study the effect of the Mueller maneuver on left ventricular performance: comparison to hemodynamics and single photon emission computed tomography perfusion patterns.

    Science.gov (United States)

    Gioia, G; Lin, B; Katz, R; DiMarino, A J; Ogilby, J D; Cassel, D; DePace, N L; Heo, J; Iskandrian, A S

    1995-11-01

    During the Mueller maneuver, there is a decrease in intrathoracic pressure and an increase in transmural left ventricular pressure. The changes in loading conditions cause transient left ventricular dysfunction. This study examined the effects of the Mueller maneuver on left ventricular performance using tantalum (Ta)-178 (half-life 9.3 min) and a multiwire gamma camera. First-pass radionuclide angiograms were obtained at baseline and during Mueller maneuver in 41 patients aged 58 +/- 10 years. In 34 patients, stress single photon emission computed tomography (SPECT) myocardial perfusion imaging with thallium-201 or sestamibi was also performed. Hemodynamic measurements during the Mueller maneuver (n = 10) showed a decrease in systemic pressure (139 +/- 25 mm Hg vs 123 +/- 24 mm Hg, p or = 5%) in 17 patients (group 2) (55% +/- 13% vs 40% +/- 16%, p = 0.001). The stress SPECT images showed no or only fixed defects in 11 (65%) patients in group 1 and 3 (18%) patients in group 2 (p = 0.02), and reversible defects in 6 (35%) patients in group 1 and 14 (82%) patients in group 2 (p = 0.04).(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  20. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi [Gunma Prefectural Cardiovascular Center, Maebashi (Japan)] [and others

    2000-04-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V{sub 2}, V{sub 3} and V{sub 4} leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV{sub F}, V{sub 5} and V{sub 6} leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  1. Effect of long-term cholesterol-lowering treatment with HMG-CoA reductase inhibitor (Simvastatin) of myocardial perfusion evaluated by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Ryohei; Nohara, Ryuji; Linxue, Li; Sasayama, Shigetake [Kyoto Univ. (Japan). Graduate School of Medicine; Tamaki, Shunichi; Hashimoto, Tetsuo; Tanaka, Masahiro; Miki, Shinji

    2000-03-01

    Fifteen patients with either angina pectoris or old myocardial infarction, who had positive {sup 201}Tl single photon emission computed tomography (SPECT) imaging and coronary sclerosis of more than 50%, were treated with an HMG-CoA reductase inhibitor (simvastatin) for more than 1 year. They were compared with an untreated control group (n=25). Total cholesterol decreased 22% and high-density lipoprotein (HDL) increased 9% with simvastatin; both changes were significantly different from those in controls. Long-term simvastatin induced improvement of myocardial perfusion on {sup 201}Tl SPECT images both during exercise and at rest, which was also significantly different from controls. In addition, the improvement of myocardial perfusion on {sup 201}Tl SPECT images was clearly related to the improvements in cholesterol values, especially nonHDL cholesterol. Thus, the greater the decrease in nonHDL cholesterol, the greater the improvement in myocardial perfusion at rest or during exercise with long-term treatment using an HMG-CoA reductase inhibitor. These findings indicate that the improvements in cholesterol values caused by HMG-CoA reductase inhibitor therapy are related to improvements of myocardial perfusion seen on {sup 201}Tl SPECT images. (author)

  2. Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Maryam Mirzaie

    2015-09-01

    Full Text Available Introduction: Left ventricular ejection fraction (LVEF is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG. This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission computed tomography (GSPECT. Materials and Methods: Overall, 48 patients with mean LVEF of 30.2% (±4.7 underwent Echocardiography and GSPECT after injection of Tc-99m-MIBI at rest. Myocardial uptake was evaluated in 17 myocardial segments and was compared with age and gender matched normal data pool. The risks and benefits of CABG were explained to the patients and 16 cases (15 male and 1 female with the mean age of 61.1 years (±10.8 accepted to undergo off-pump CABG. All the patients were followed-up for at least six months and echocardiography and GSPECT were repeated at the end of follow up. Results: The mean LVEF was increased from of 31.1% (±3.5 to 34.5% (±3.6 after surgery (P

  3. Changes in distribution of reticuloendothelial function in transcatheter arterial embolization (TAE) for hepatocellular carcinoma (HCC), estimated by single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Taniai, Nobuhiko; Onda, Masahiko; Tajiri, Takashi; Kim, Tokuei [Nippon Medical School, Tokyo (Japan)

    1995-06-01

    In order to study the changes in distribution of reticuloendothelial function in transcatheter arterial embolization (TAE) for hepatocellular carcinoma (HCC), the radioactivity of {sup 99m}Tc-phytate was calculated by the accumulation rate in the organs by means of the single emission computed tomography (SPECT). It was regarded as the reticuloendothelial function in the liver and spleen, and was evaluated independently. Before TAE, the significant increases were noted in both splenic activity and splenic volume in the cirrhotic patients, as compared with non-cirrhotic patients. After TAE, the activity in the liver was reduced at the first day after TAE, which returned to the normal level by 5 days. While that in the spleen increased immediately after TAE. After one day of TAE, reticuloendothelial functions of the spleen was significantly higher in the cirrhotic cases then in the non-cirrhotic cases. Furthermore, in the cirrhotic patients, it was significantly higher in the cases embolizated in more than two segments than in those embolizated in one segment only. In conclusion, the reticuloendothelial function of the liver was significantly reduced by the TAE in the cirrhotic patients as compared with non-cirrhotic patients. However the reduced reticuloendothelial function of the liver in the cirrhotic patients was compensated by the increased reticuloendothelial function of the spleen. (author).

  4. Phantom evaluation of scatter and attenuation correction in thallium-201/technetium-99m acquisition in myocardial perfusion single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ohyama, Yoichi; Tomiguchi, Seiji; Kira, Tomohiro; Kojima, Akihiro; Matsumoto, Masanori; Nishi, Jyunko; Katsuda, Noboru; Takahashi, Mutsumasa [Kumamoto Univ. (Japan). School of Medicine; Motomura, Nobutoku

    2001-04-01

    This phantom study was carried out to evaluate the usefulness of scatter correction combined with transmission-based attenuation correction in separate and simultaneous {sup 201}Tl/{sup 99m}Tc myocardial SPECT. An anthropomorphic torso phantom was used in this study. We used the triple-energy-window (TEW) method for scatter correction and transmission computed tomography (TCT) images for attenuation correction. Images without corrections (UC) and images with corrections (SAC) for scatter and attenuation were reconstructed for the evaluation. The differences in defect size between {sup 99m}Tc and {sup 201}Tl UC images led to interpretation errors in separate (separate protocol) and simultaneous dual-isotope studies (simultaneous protocol). These errors were more prominent in the infero-posterior wall in the simultaneous protocol. Improvement for overestimation in object size and underestimation in defect contrast was visually obtained, and increased contrast was also shown by the myocardium-to-defect count (MD) ratios on SAC images in the separate and simultaneous protocols. However, {sup 201}Tl SAC images in the simultaneous protocol still had less defect contrast than the corresponding {sup 201}Tl SAC images in the separate protocol. From the results of our phantom experiment, separate rest {sup 201}Tl/ stress {sup 99m}Tc-sestamibi acquisitions may be recommended in clinical practice. Further clinical and phantom studies will be needed to validate the method using scatter correction combined with transmission-based attenuation correction. (author)

  5. Demonstration of quantum permutation algorithm with a single photon ququart.

    Science.gov (United States)

    Wang, Feiran; Wang, Yunlong; Liu, Ruifeng; Chen, Dongxu; Zhang, Pei; Gao, Hong; Li, Fuli

    2015-06-05

    We report an experiment to demonstrate a quantum permutation determining algorithm with linear optical system. By employing photon's polarization and spatial mode, we realize the quantum ququart states and all the essential permutation transformations. The quantum permutation determining algorithm displays the speedup of quantum algorithm by determining the parity of the permutation in only one step of evaluation compared with two for classical algorithm. This experiment is accomplished in single photon level and the method exhibits universality in high-dimensional quantum computation.

  6. Automated characterization of single-photon avalanche photodiode

    CERN Document Server

    Ghazali, Aina M M; Sauge, Sebastien; Makarov, Vadim

    2012-01-01

    We report an automated characterization of a single-photon detector based on commercial silicon avalanche photodiode (PerkinElmer C30902SH). The photodiode is characterized by I-V curves at different illumination levels (darkness, 10 pW and 10 uW), dark count rate and photon detection efficiency at different bias voltages. The automated characterization routine is implemented in C++ running on a Linux computer.

  7. Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography.

    Science.gov (United States)

    Tian, Qin; Zhang, Fucheng; Wang, Yanming; Qu, Weiqiang

    2014-01-01

    To use different beam arrangements and numbers to plan intensity-modulated radiation therapy (IMRT) and investigate their effects on low and high radiation doses delivered to the functional lung, in order to reduce radiation-induced lung damage. Ten patients with stage I-III non-small cell lung carcinoma (NSCLC) underwent IMRT. Beam arrangements were selected on the basis of orientation and dose-volume histograms to create SPECT-guided IMRT plans that spared the functional lung and maintained target coverage. Four different plans, including CT-7, SPECT-7, SPECT-4, SPECT-5 with different beam arrangements, were used. The differences of conformity index (CI), heterogeneity index (HI) between the plans were analyzed, by using a paired t-test. The seven-beam SPECT (SPECT-7) plan reduced the volume of the functional lung irradiated with at least 20 Gy (FV20) and 30 Gy (FV30) by 26.02% ±15.45% and 14.41% ±16.66%, respectively, as compared to the seven-beam computed tomography (CT-7) plan. The CI significantly differed between the SPECT-7 and SPECT-4 plans and between the SPECT-5 and SPECT-4 plans, but not between the SPECT-5 and SPECT-7 plans. The CIs in the SPECT-5 and SPECT-7 plans were better than that in the SPECT-4 plan. The heterogeneity index significantly differed among the three SPECT plans and was best in the SPECT-7 plan. The incorporation of SPECT images into IMRT planning for NSCLC greatly affected beam angles and number of beams. Fewer beams and modified beam angles achieved similar or better IMRT quality. The low-dose volumes were lower in SPECT-4.

  8. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  9. A review on single photon sources in silicon carbide

    Science.gov (United States)

    Lohrmann, A.; Johnson, B. C.; McCallum, J. C.; Castelletto, S.

    2017-03-01

    This paper summarizes key findings in single-photon generation from deep level defects in silicon carbide (SiC) and highlights the significance of these individually addressable centers for emerging quantum applications. Single photon emission from various defect centers in both bulk and nanostructured SiC are discussed as well as their formation and possible integration into optical and electrical devices. The related measurement protocols, the building blocks of quantum communication and computation network architectures in solid state systems, are also summarized. This includes experimental methodologies developed for spin control of different paramagnetic defects, including the measurement of spin coherence times. Well established doping, and micro- and nanofabrication procedures for SiC may allow the quantum properties of paramagnetic defects to be electrically and mechanically controlled efficiently. The integration of single defects into SiC devices is crucial for applications in quantum technologies and we will review progress in this direction.

  10. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  11. Superconducting nanowire single-photon imager

    CERN Document Server

    Zhao, Qing-Yuan; Calandri, Niccolò; Dane, Andrew E; McCaughan, Adam N; Bellei, Francesco; Wang, Hao-Zhu; Santavicca, Daniel F; Berggren, Karl K

    2016-01-01

    Detecting spatial and temporal information of individual photons is a crucial technology in today's quantum information science. Among the existing single-photon detectors, superconducting nanowire single-photon detectors (SNSPDs) have been demonstrated with a sub-50 ps timing jitter, near unity detection efficiency1, wide response spectrum from visible to infrared and ~10 ns reset time. However, to gain spatial sensitivity, multiple SNSPDs have to be integrated into an array, whose spatial and temporal resolutions are limited by the multiplexing circuit. Here, we add spatial sensitivity to a single nanowire while preserving the temporal resolution from an SNSPD, thereby turning an SNSPD into a superconducting nanowire single-photon imager (SNSPI). To achieve an SNSPI, we modify a nanowire's electrical behavior from a lumped inductor to a transmission line, where the signal velocity is slowed down to 0.02c (where c is the speed of light). Consequently, we are able to simultaneously read out the landing locati...

  12. Room temperature stable single-photon source

    CERN Document Server

    Beveratos, A; Brouri, R; Gacoin, T; Poizat, J P; Grangier, P; Beveratos, Alexios; Kuehn, Sergei; Brouri, Rosa; Gacoin, Thierry; Poizat, Jean-Philippe; Grangier, Philippe

    2001-01-01

    We report on the realization of a stable solid state room temperature source for single photons. It is based on the fluorescence of a single nitrogen-vacancy (NV) color center in a diamond nanocrystal. Antibunching has been observed in the fluorescence light under both continuous and pulsed excitation. Our source delivers 2*10^4 single-photon pulses per second at an excitation repetition rate of 10 MHz. The number of two-photon pulses is reduced by a factor of five compared to strongly attenuated coherent sources.

  13. Advantages of gated silicon single photon detectors

    CERN Document Server

    Lunghi, T; Barreiro, C; Stucki, D; Sanguinetti, B; Zbinden, H

    2012-01-01

    We present a gated silicon single photon detector based on a commercially available avalanche photodiode. Our detector achieves a photon detection efficiency of 45\\pm5% at 808 nm with 2x 10^-6 dark count per ns at -30V of excess bias and -30{\\deg}C. We compare gated and free-running detectors and show that this mode of operation has significant advantages in two representative experimental scenarios: detecting a single photon either hidden in faint continuous light or after a strong pulse. We also explore, at different temperatures and incident light intensities, the "charge persistence" effect, whereby a detector clicks some time after having been illuminated.

  14. Quantum identity authentication with single photon

    Science.gov (United States)

    Hong, Chang ho; Heo, Jino; Jang, Jin Gak; Kwon, Daesung

    2017-10-01

    Quantum identity authentication with single photons is proposed in the paper. It can verify a user's identity without exposing to an authentication key information. The protocol guarantees high efficiency in that it can verify two bits of authentication information using just a single photon. The security of our authentication scheme is analyzed and confirmed in the case of a general attack. Moreover, the proposed protocol is practicable with current technology. Our quantum identity authentication protocol does not require quantum memory registration and any entangled photon sources.

  15. Impact of intracoronary injection of mononuclear bone marrow cells in acute myocardial infarction on left ventricular perfusion and function: a 6-month follow-up gated {sup 99m}Tc-MIBI single-photon emission computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Lipiec, Piotr [Medical University of Lodz, 2nd Department of Cardiology, Lodz (Poland); Medical University of Lodz, 2nd Department of Cardiology, Bieganski Hospital, Lodz (Poland); Krzeminska-Pakula, Maria; Plewka, Michal; Kasprzak, Jaroslaw D. [Medical University of Lodz, 2nd Department of Cardiology, Lodz (Poland); Kusmierek, Jacek; Plachcinska, Anna; Szuminski, Remigiusz [Medical University of Lodz, Department of Nuclear Medicine, Lodz (Poland); Robak, Tadeusz; Korycka, Anna [Medical University of Lodz, Department of Hematology, Lodz (Poland)

    2009-04-15

    We investigated the impact of intracoronary injection of autologous mononuclear bone marrow cells (BMC) in patients with acute ST elevation myocardial infarction (STEMI) on left ventricular volumes, global and regional systolic function and myocardial perfusion. The study included 39 patients with first anterior STEMI treated successfully with primary percutaneous coronary intervention. They were randomly assigned to the treatment group or the control group in a 2:1 ratio. The patients underwent baseline gated single-photon emission computed tomography (G-SPECT) 3-10 days after STEMI with quantitative and qualitative analysis of left ventricular perfusion and systolic function. On the following day, patients from the BMC treatment group were subjected to bone marrow aspiration, mononuclear BMC isolation and intracoronary injection. No placebo procedure was performed in the control group. G-SPECT was repeated 6 months after STEMI. Baseline and follow-up G-SPECT studies were available for 36 patients. At 6 months in the BMC group we observed a significantly enhanced improvement in the mean extent of the perfusion defect, the left ventricular perfusion score index, the infarct area perfusion score and the infarct area wall motion score index compared to the control group (p=0.01-0.04). However, the changes in left ventricular volume, ejection fraction and the left ventricular wall motion score index as well as the relative changes in the infarct area wall motion score index did not differ significantly between the groups. Intracoronary injection of autologous mononuclear BMC in patients with STEMI improves myocardial perfusion at 6 months. The benefit in infarct area systolic function is less pronounced and there is no apparent improvement of global left ventricular systolic function. (orig.)

  16. Reduced regional cerebral blood flow in aged noninsulin-dependent diabetic patients with no history of cerebrovascular disease: evaluation by N-isopropyl- sup 123 I-p-iodoamphetamine with single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wakisaka, M.; Nagamachi, S.; Inoue, K.; Morotomi, Y.; Nunoi, K.; Fujishima, M. (Higashi Hospital, (Japan))

    1990-10-01

    Regional cerebral blood flow was measured using N-isopropyl-{sup 123}I-iodoamphetamine with single-photon emission computed tomography (CT) in 16 aged patients with noninsulin-dependent diabetes mellitus (NIDDM, average age 72.8 years, average fasting plasma glucose 7.7 mmol/L), and 12 nondiabetic subjects (71.6 years, 5.3 mmol/L). None had any history of a cerebrovascular accident. Systolic blood pressure (SBP), total cholesterol, and triglyceride levels did not differ between groups. Areas of hypoperfusion were observed in 14 diabetic patients (12 patients had multiple lesions) and in 6 nondiabetic subjects (3 had multiple lesions). Areas where radioactivity was greater than or equal to 65% of the maximum count of the slice was defined as a region with normal cerebral blood flow (region of interest A, ROI-A), and areas where the count was greater than or equal to 45% were defined as brain tissue regions other than ventricles (ROI-B). The average ROI-A/B ratio of 16 slices was used as a semiquantitative indicator of normal cerebral blood flow throughout the entire brain. Mean ROI-A/B ratio was 49.6 +/- 1.7% in the diabetic group, significantly lower than the 57.9 +/- 1.6% at the nondiabetic group (p less than 0.005). The ratio was inversely correlated with SBP (r = -0.61, p less than 0.05), total cholesterol (r = -0.51, p less than 0.05), and atherogenic index (r = -0.64, p less than 0.01), and was positively correlated with high-density lipoprotein (HDL) cholesterol (r = 0.51, p less than 0.05) in the diabetic, but not the nondiabetic group. These observations suggest that the age-related reduction in cerebral blood flow may be accelerated by a combination of hyperglycemia plus other risk factors for atherosclerosis.

  17. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Woo [Dept. of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University School of Medicine, Seoul (Korea, Republic of); Kim, Ki Bong; Lee, Dong Soo [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    The aim of this study was to investigate the most robust predictor of myocardial viability among stress/rest reversibility (coronary flow reserve [CFR] impairment), {sup 201}Tl perfusion status at rest, {sup 201}Tl 24 hours redistribution and systolic wall thickening of {sup 99m}Tc-methoxyisobutylisonitrile using a dual isotope gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with coronary artery disease (CAD) who were re-vascularized with a coronary artery bypass graft (CABG) surgery. A total of 39 patients with CAD was enrolled (34 men and 5 women), aged between 36 and 72 years (mean 58 ± 8 standard in years) who underwent both pre- and 3 months post-CABG myocardial SPECT. We analyzed 17 myocardial segments per patient. Perfusion status and wall motion were semi-quantitatively evaluated using a 4-point grading system. Viable myocardium was defined as dysfunctional myocardium which showed wall motion improvement after CABG. The left ventricular ejection fraction (LVEF) significantly increased from 37.8 ± 9.0% to 45.5 ± 12.3% (p < 0.001) in 22 patients who had a pre-CABG LVEF lower than 50%. Among 590 myocardial segments in the re-vascularized area, 115 showed abnormal wall motion before CABG and 73.9% (85 of 115) had wall motion improvement after CABG. In the univariate analysis (n = 115 segments), stress/rest reversibility (p < 0.001) and {sup 201}Tl rest perfusion status (p = 0.024) were significant predictors of wall motion improvement. However, in multiple logistic regression analysis, stress/rest reversibility alone was a significant predictor for post-CABG wall motion improvement (p < 0.001). Stress/rest reversibility (impaired CFR) during dual-isotope gated myocardial perfusion SPECT was the single most important predictor of wall motion improvement after CABG.

  18. Regional Cerebral Blood Flow in [123]I-IMP Single-photon Emission Computed Tomography and the Wechsler Memory Scale-revised in Nondemented Elderly Subjects with Subjective Cognitive Impairment.

    Science.gov (United States)

    Niwa, Fumitoshi; Kondo, Masaki; Sakurada, Kumi; Nakagawa, Masanori; Imanishi, Jiro; Mizuno, Toshiki

    Objective Regional cerebral blood flow (rCBF) imaging with single-photon emission computed tomography (SPECT) is useful in the early diagnosis of dementia. We aimed to investigate the association between the rCBF and various domains related to the memory function in elderly subjects with subjective cognitive impairment (SCI). Methods Thirty-two subjects with SCI were included in the present study. Patients with dementia and mild cognitive impairment (MCI) were excluded based on the presence of logical memory impairment. N-isopropyl-p-[(123)I]-iodoamphetamine SPECT was performed and Wechsler Memory Scale-Revised (WMS-R) was administered to all subjects (mean age, 68.4 years; average Mini-Mental State Examination score, 27.6). The SPECT results were analyzed using the easy Z-score imaging system and the voxel-based stereotactic extraction estimation method. Correlation analyses were performed to investigate the correlation between the mean positive Z-scores in the decrease of the rCBF and the WMS-R indices. Results The SPECT study indicated marked hypoperfusion in some areas, including the bilateral temporal areas, the caudate, and the thalamus, in these subjects in comparison to the normal database. The decrease in the rCBF that was observed in several regions, including the left precuneus and left inferior frontal gyrus (LIFG), showed a significant negative correlation with several indices of the memory function, particularly visual memory. Conclusion The regional hypoperfusion observed in the study using the voxel-based stereotactic extraction estimation method suggest that the regional cerebral dysfunction is associated with the memory function of patients with SCI, even though the subjects in the present study were cognitively intact. The correlation analysis with the WMS-R suggested the contribution of the LIFG to the memory function and indicated the significance of visual memory dysfunction in the neuropsychological assessment to determine the stage of SCI.

  19. Single Photon Emission Computed Tomography (SPECT) Experience with (S)-5-[123I]iodo-3-(2-azetidinylmethoxy)pyridine (5-[123I]IA) in the Living Human Brain of Smokers and Nonsmokers

    Science.gov (United States)

    BRAŠIĆ, JAMES ROBERT; ZHOU, YUN; MUSACHIO, JOHN L.; HILTON, JOHN; FAN, HONG; CRABB, ANDREW; ENDRES, CHRISTOPHER J.; REINHARDT, MELVIN J.; DOGAN, AHMET S.; ALEXANDER, MOHAB; ROUSSET, OLIVIER; MARIS, MARIKA A.; GALECKI, JEFFREY; NANDI, AYON; WONG, DEAN F.

    2009-01-01

    (S)-5-[123I]iodo-3-(2-azetidinylmethoxy)pyridine (5-[123I]IA), a novel potent radioligand for high-affinity α4β2* neuronal nicotinic acetylcholine receptors (nAChRs), provides a means to evaluate the density and the distribution of nAChRs in the living human brain. We sought in healthy adult smokers and nonsmokers to (1) evaluate the safety, tolerability, and efficacy of 5-[123I]IA in an open nonblind trial and (2) to estimate the density and distribution of α4β2* nAChRs in the brain. Single photon emission computed tomography (SPECT) was performed for five hours after the intravenous administration of approximately 0.001 μg/kg (approximately 10 mCi) 5-[123I]IA. Blood pressure, heart rate, and neurobehavioral status were monitored before, during, and after the administration of 5-[123I]IA to twelve healthy adults (8 men and 4 women) (6 smokers and 6 nonsmokers) ranging in age from 19 to 46 years (mean = 28.25, standard deviation = 8.20). High plasma nicotine level was significantly associated with low 5-[123I]IA binding in (1) the caudate head, the cerebellum, the cortex, and the putamen, utilizing both the Sign and Mann-Whitney U tests, (2) the fusiform gyrus, the hippocampus, the parahippocampus, and the pons utilizing the Mann-Whitney U test, and (3)the thalamus utilizing the Sign test. We conclude that 5-[123I]IA is a safe, well-tolerated, and effective pharmacologic agent for human subjects to estimate high-affinity α4/β2 nAChRs in the living human brain. PMID:19140167

  20. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-{beta}-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Shimoyama, Katsuya [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-10-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using {sup 123}I-{beta}-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and {sup 201}thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p<0.042). However, when Tl defect score was larger than BMIPP defect score, an increase in Tl defect score was slight. A significant negative correlation was found between the sum of the BMIPP and Tl defect scores and the left ventricular ejection fraction (LVEF) (r=0.66, p<0.0001). According to the histo-pathological study of two autopsied hearts, severe myocardial fibrosis was seen in segments with fixed perfusion defect. In addition, the mismatched segments of BMIPP defect score > Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  1. Prognostic value of myocardial perfusion single photon emission computed tomography for major adverse cardiac cerebrovascular and renal events in patients with chronic kidney disease: results from first year of follow-up of the Gunma-CKD SPECT multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Kasama, Shu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Cardiovascular Hospital of Central Japan (Kitakanto Cardiovascular Hospital), Department of Cardiovascular Medicine, Gunma (Japan); Toyama, Takuji [Department of Cardiovascular Medicine, Gunma Prefectural Cardiovascular Center, Maebashi (Japan); Sato, Makito [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Tatebayashi Kosei Hospital, Department of Internal Medicine, Gunma (Japan); Sano, Hirokazu [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Isesaki Municipal Hospital, Department of Cardiovascular Medicine, Isesaki (Japan); Ueda, Tetsuya [Fujioka General Hospital, Division of Cardiology, Fujioka (Japan); Sasaki, Toyoshi [Takasaki General Medical Center, Division of Cardiology, Takasaki (Japan); Nakahara, Takehiro; Kurabayashi, Masahiko [Gunma University Graduate School of Medicine, Department of Medicine and Biological Science (Cardiovascular Medicine), Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi (Japan)

    2016-02-15

    Patients with chronic kidney disease (CKD) have an increased risk of adverse cardio-cerebrovascular events. We examined whether stress myocardial perfusion single photon emission computed tomography (SPECT) provides reliable prognostic markers for these patients. In this multicenter, prospective cohort trial from the Gunma-CKD SPECT study protocol, patients with CKD [estimated glomerular filtration rate (eGFR) < 60 min/ml per 1.73 m{sup 2}] undergoing stress {sup 99m}Tc-tetrofosmin SPECT for suspected or possible ischemic heart disease were initially followed for 1 year, with the following study endpoints: primary, the occurrence of cardiac deaths (CDs), and secondary, major adverse cardiac, cerebrovascular, and renal events (MACCREs). The summed stress score (SSS), summed rest score, and summed difference score (SDS) were estimated with the standard 17-segment, 5-point scoring model. Left ventricular end-diastolic volume, end-systolic volume (ESV), and ejection fraction were measured using electrocardiogram-gated SPECT. During the first year of follow-up, 69 of 299 patients experienced MACCREs (CD, n = 7; non-fatal myocardial infarction, n = 3; hospitalization for heart failure, n = 13; cerebrovascular accident, n = 1; need for revascularization, n = 38; and renal failure, i.e., hemodialysis initiation, n = 7). ESV and SSS were associated with CDs (p < 0.05), and eGFR and SDS were associated with MACCREs (p < 0.05), in multivariate logistic analysis. Patients with high ESV and high SSS had a significantly higher CD rate during the first year than the other CKD patient subgroups (p < 0.05). Patients with low eGFR and high SDS had a significantly higher MACCRE rate than the other subgroups (p < 0.05). Myocardial perfusion SPECT can provide reliable prognostic markers for patients with CKD. (orig.)

  2. Distribution of Functional Liver Volume in Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus in the 1st Branch and Main Trunk Using Single Photon Emission Computed Tomography—Application to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    Akira Ikoma

    2011-10-01

    Full Text Available Purpose: To analyze the distribution of functional liver volume (FLV in the margin volume (MV surrounding hepatocellular carcinoma (HCC with portal vein tumor thrombus (PVTT before radiation therapy (RT and to verify the safety of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B3DCRT by exploring the relation of FLV in MV to radiation-induced liver disease (RILD. Methods and Materials: Clinical target volume (CTV included main tumor and PVTT, and planning target volume (PTV included CTV with a 10 mm margin. MV was defined as PTV–CTV. FLV ratio in MV was calculated as FLV in MV/MV × 100 (%. The two high-dose beams were planned to irradiate FLV as little as possible. Fifty-seven cases of HCC (26/57, 46%; Child–Pugh grade B with PVTT underwent SPECT-B3DCRT which targeted the CTV to a total dose of 45 Gy/18 fractions. The destructive ratio was defined as radiation induced dysfunctional volume/FLV × 100 (%. Results: We observed a significant negative correlation between FLV ratio in MV and CTV (p < 0.001. Three cases with CTVs of 287, 587 and 1184 cm3 experienced transient RILD. The FLV ratio in MV was highest in patients with RILD: nine patients with CTV of 200–300 cm3, three with CTV of 500–600 cm3, and two with CTV of 1100–1200 cm3. The destructive ratio yielded a mean value of 24.2 ± 1.5%. Conclusions: Radiation planning that takes into account the distribution of FLV appears to result in the least possible RILD.

  3. Interactive Screen Experiments with Single Photons

    Science.gov (United States)

    Bronner, Patrick; Strunz, Andreas; Silberhorn, Christine; Meyn, Jan-Peter

    2009-01-01

    Single photons are used for fundamental quantum physics experiments as well as for applications. Originally being a topic of advance courses, such experiments are increasingly a subject of undergraduate courses. We provide interactive screen experiments (ISE) for supporting the work in a real laboratory, and for students who do not have access to…

  4. Infrared Superconducting Single-Photon Detectors

    Science.gov (United States)

    2012-10-05

    group realized small microstrip devices, the next iteration of which may narrow the line width to below 100 nm, entering the single-photon detection...and will explore superconducting detectors with integrated waveguide circuits and novel deposition techniques. 15. SUBJECT...world record quantum cryptography demonstrations [9] and operation of quantum waveguide circuits at telecom wavelengths [10]. Beyond the quantum

  5. Single Photon Experiments and Quantum Complementarity

    Directory of Open Access Journals (Sweden)

    Georgiev D. D.

    2007-04-01

    Full Text Available Single photon experiments have been used as one of the most striking illustrations of the apparently nonclassical nature of the quantum world. In this review we examine the mathematical basis of the principle of complementarity and explain why the Englert-Greenberger duality relation is not violated in the configurations of Unruh and of Afshar.

  6. Single-photon imaging in CMOS

    NARCIS (Netherlands)

    Charbon, E.

    2010-01-01

    We report on the architectural design and fabrication of medium and large arrays of single-photon avalanche diodes (SPADs) for a variety of applications in physics, medicine, and the life sciences. Due to dynamic nature of SPADs, designs featuring a large number of SPADs require careful analysis of

  7. Coherent single-photon absorption by single emitters coupled to one-dimensional nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper;

    2011-01-01

    We study the dynamics of single-photon absorption by a single emitter coupled to a one-dimensional waveguide that simultaneously provides channels for spontaneous emission (SE) decay and a channel for the input photon. We have developed a time-dependent theory that allows us to specify any input ...... can be improved by a further 4% by engineering the dispersion. Efficient single-photon absorption by a single emitter has potential applications in quantum communication and quantum computation....

  8. Single photonics at telecom wavelengths using nanowire superconducting detectors

    CERN Document Server

    Zinoni, C; Fiore, A; Gerardino, A; Goltsman, G N; Li, L H; Lunghi, L; Marsili, F; Smirnov, K V; Vakhtomin, Y B; Vakhtomin, Yu. B.

    2006-01-01

    Single photonic applications - such as quantum key distribution - rely on the transmission of single photons, and require the ultimate sensitivity that an optical detector can achieve. Single-photon detectors must convert the energy of an optical pulse containing a single photon into a measurable electrical signal. We report on fiber-coupled superconducting single-photon detectors (SSPDs) with specifications that exceed those of avalanche photodiodes (APDs), operating at telecommunication wavelength, in sensitivity, temporal resolution and repetition frequency. The improved performance is demonstrated by measuring the intensity correlation function g(2)(t) of single-photon states at 1300nm produced by single semiconductor quantum dots (QDs).

  9. Observation of Single-Photon Switching

    CERN Document Server

    Chen, Y F; Liu, Y C; Yu, I A; Chen, Yong-Fan; Tsai, Zen-Hsiang; Liu, Yu-Chen; Yu, Ite A.

    2005-01-01

    We report an experimental demonstration of single-photon switching in laser-cooled $^{87}$Rb atoms. A resonant probe pulse with an energy per unit area of one photon per $\\lambda^2/2\\pi$ propagates through the optically thick atoms. Its energy transmittance is greater than 63% or loss is less than $e^{-1}$ due to the effect of electromagnetically induced transparency. In the presence of a switching pulse with an energy per unit area of 1.4 photons per $\\lambda^2/2\\pi$, the energy transmittance of the same probe pulse becomes less than 37% or $e^{-1}$. This substantial reduction of the probe transmittance caused by single switching photons has potential applications in single-photon-level nonlinear optics and the manipulation of quantum information.

  10. SINGLE: single photon sensitive cryogenic light detectors

    Science.gov (United States)

    Biassoni, Matteo; SINGLE Collaboration

    2017-09-01

    Thermal detectors operated at few mK as calorimeters are a powerful tool for the study of rare particle physics processes. In order to implement particle identification, light detection can be effectively performed by means of other thermal detectors operated as light sensors. This configuration can be used also in large scale, thousand-channels setups, but the light sensors must be sensitive enough to detect few, possibly a single, photons. The SINGLE project described here aims at producing silicon based, large area devices that can be operated as thermal detectors with single-photon sensitivity, and demonstrate the reliability of the performance, scalability of the production process and integrability with present and next generation cryogenic experiments for the search for rare events.

  11. T-shaped single-photon router.

    Science.gov (United States)

    Lu, Jing; Wang, Z H; Zhou, Lan

    2015-09-07

    We study the transport properties of a single photon scattered by a two-level system (TLS) in a T-shaped waveguide, which is made of two coupled-resonator waveguides (CRWs)- an infinite CRW and a semi-infinite CRW. The spontaneous emission of the TLS directs single photons from one CRW to the other. Although the transfer rate is different for the wave incident from different CRWs, due to the boundary breaking the translational symmetry, the boundary can enhance the transfer rate found in Phys. Rev. Lett. 111, 103604 (2013) and Phys. Rev. A 89, 013805 (2014), as the transfer rate could be unity for the wave incident from the semi-infinite CRW.

  12. Advantages of gated silicon single photon detectors

    Science.gov (United States)

    Legré, Matthieu; Lunghi, Tommaso; Stucki, Damien; Zbinden, Hugo

    2013-05-01

    We present gated silicon single photon detectors based on two commercially available avalanche photodiodes (APDs) and one customised APD from ID Quantique SA. This customised APD is used in a commercially available device called id110. A brief comparison of the two commercial APDs is presented. Then, the charge persistence effect of all of those detectors that occurs just after a strong illumination is shown and discussed.

  13. Quantitation of regional cerebral blood flow by single photon emission computed tomography of CBF-tracer combined with whole-brain CBF; A comparison between [sup 123]I-IMP and [sup 99m]Tc-HMPAO in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Isaka, Yoshinari; Imaizumi, Masatoshi; Ashida, Keiichi; Ohe, Yosuke; Okamoto, Masaya; Abe, Tohru; Tanaka, Seiji (Osaka National Hospital (Japan))

    1994-05-01

    A simple, noninvasive method of measuring cerebral blood flow (CBF) that uses single-photon emission computed tomography (SPECT) of CBF-tracer and whole brain CBF obtained by xenon-133 ([sup 133]Xe) clearance technique was developed. In nine healthy volunteers, SPECT data were normalized to the count density of [sup 123]I-IMP or [sup 99m]Tc-HMPAO uptake in the whole-brain, and then converted to the absolute units of CBF by multiplying average [sup 133]Xe-CBF in the whole brain. The CBF values measured by [sup 99m]Tc-HMPA CBF-SPECT was significantly lower in the high flow regions of cortical gray matter (bilateral frontal lobe; p<0.05 and right occipital lobe; p<0.05), and was significantly higher in the bilateral white matter (p<0.05 or 0.01) and the cerebellum (p<0.005) compared with the flow values measured by [sup 123]I-IMP CBF-SPECT. Whereas, the IMP-CBF values were significantly lower in the bilateral striatum (p<0.02 or 0.05) compared with the HMPAO-CBF values. Good correlations were found between IMP-CBF and the HMPAO-CBF values in the cortical gray matter (r[sub s]=0.761; p<0.001, n=108), the white matter (r[sub s]=0.739; p<0.001, n=18) and the cerebellum (r[sub s]=0.731; p<0.001, n=18). In the striatum (r[sub s]=0.58; p<0.05, n=18) and the thalamus (r[sub s]=0.628; p<0.05, n=18), the correlations between IMP-CBF and HMPAO-CBF values were inferior to those of the other three regions. The results indicated that the contrast between high and low CBF regions in the HMPAO CBF-SPECT was significantly less than that in the IMP CBF-SPECT. However, this assumption is not applicable in all of the cerebral regions. (author).

  14. Detection of single photons by toad and mouse rods.

    Science.gov (United States)

    Reingruber, Jürgen; Pahlberg, Johan; Woodruff, Michael L; Sampath, Alapakkam P; Fain, Gordon L; Holcman, David

    2013-11-26

    Amphibian and mammalian rods can both detect single photons of light even though they differ greatly in physical dimensions, mammalian rods being much smaller in diameter than amphibian rods. To understand the changes in physiology and biochemistry required by such large differences in outer segment geometry, we developed a computational approach, taking into account the spatial organization of the outer segment divided into compartments, together with molecular dynamics simulations of the signaling cascade. We generated simulations of the single-photon response together with intrinsic background fluctuations in toad and mouse rods. Combining this computational approach with electrophysiological data from mouse rods, we determined key biochemical parameters. On average around one phosphodiesterase (PDE) molecule is spontaneously active per mouse compartment, similar to the value for toad, which is unexpected due to the much smaller diameter in mouse. A larger number of spontaneously active PDEs decreases dark noise, thereby improving detection of single photons; it also increases cGMP turnover, which accelerates the decay of the light response. These constraints explain the higher PDE density in mammalian compared with amphibian rods that compensates for the much smaller diameter of mammalian disks. We further find that the rate of cGMP hydrolysis by light-activated PDE is diffusion limited, which is not the case for spontaneously activated PDE. As a consequence, in the small outer segment of a mouse rod only a few activated PDEs are sufficient to generate a signal that overcomes noise, which permits a shorter lifetime of activated rhodopsin and greater temporal resolution.

  15. Transmitting more than 10 bit with a single photon

    NARCIS (Netherlands)

    Tentrup, T.B.H.; Hummel, T.; Wolterink, T.A.W.; Uppu, R.; Mosk, A.P.; Pinkse, P.W.H.

    2016-01-01

    Encoding information in the position of single photons has no known limits, given infinite resources. Using a heralded single-photon source and a Spatial Light Modulator (SLM), we steer single photons to specific positions in a virtual grid on a large-area spatially resolving photon-counting detecto

  16. Detecting single photons: a supramolecular matter?

    Science.gov (United States)

    Cangiano, Lorenzo; Dell'Orco, Daniele

    2013-01-04

    Rod photoreceptors detect single photons through a tradeoff of light collecting ability, amplification and speed. Key roles are played by rhodopsin (Rh) and transducin (G(t)), whose complex supramolecular organization in outer segment disks begs for a functional interpretation. Here we review past and recent evidence of a temperature-dependence of photon detection by mammalian rods, and link this phenomenon with the putative oligomeric organization of Rh and new ideas on the dynamics of Rh-G(t) interaction. Identifying an electrophysiological correlate of the supramolecular organization of Rh and G(t) may shed light on the evolutionary advantage it confers to night vision.

  17. Discriminating orthogonal single-photon images

    Science.gov (United States)

    Broadbent, Curtis J.; Zerom, Petros; Shin, Heedeuk; Howell, John C.; Boyd, Robert W.

    2009-03-01

    We can encode an image from an orthogonal basis set onto a single photon from a downconverted pair via the use of an amplitude mask. We can then discriminate the image imprinted on the photon from other images in the set using holographic-matched filtering techniques. We demonstrate this procedure experimentally for an image space of two objects, and we discuss the possibility of applying this method to a much larger image space. This process could have important implications for the manipulation of images at the quantum level.

  18. Purification of a single photon nonlinearity

    CERN Document Server

    Snijders, H; Norman, J; Bakker, M P; Gossard, A; Bowers, J E; van Exter, M P; Bouwmeester, D; Löffler, W

    2016-01-01

    We show that the lifetime-reduced fidelity of a semiconductor quantum dot-cavity single photon nonlinearity can be restored by polarization pre- and postselection. This is realized with a polarization degenerate microcavity in the weak coupling regime, where an output polarizer enables quantum interference of the two orthogonally polarized transmission amplitudes. This allows us to transform incident coherent light into a stream of strongly correlated photons with a second-order correlation function of g2(0)~40, larger than previous experimental results even in the strong-coupling regime. This purification technique might also be useful to improve the fidelity of quantum dot based logic gates.

  19. Single-Photon Detection at Telecom Wavelengths

    Institute of Scientific and Technical Information of China (English)

    SUN Zhi-Bin; MA Hai-Qiang; LEI Ming; WANG Di; LIU Zhao-Jie; YANG Han-Dong; WU Ling-An; ZHAI Guang-Jie; FENG Ji

    2007-01-01

    A single-photon detector based on an InGaAs avalanche photodiode has been developed for use at telecom wavelengths. A suitable delay and sampling gate modulation circuit are used to prevent positive and negative transient pulses from influencing the detection of true photon induced avalanches. A monostable trigger circuit eliminates the influence of avalanche peak jitter, and a dead time modulation feedback control circuit decreases the afterpulsing. From performance tests we find that at the optimum operation point, the quantum efficiency is 12% and the dark count rate 1.5 × 10-6 ns-1, with a detection rate of 500 kHz.

  20. An experimental demonstration of single photon nonlocality

    CERN Document Server

    Hessmo, B; Heydari, H; Björk, G; Hessmo, Bj\\"orn; Usachev, Pavel; Heydari, Hoshang; Bj\\"ork, Gunnar

    2003-01-01

    In this letter we experimentally implement a single photon Bell test based on the ideas of S. Tan et al. [Phys. Rev. Lett., vol. 66, 252 (1991)] and L. Hardy [Phys. Rev. Lett.,vol. 73, 2279 (1994)]. A double heterodyne measurement is used to measure correlations in the Fock space spanned by zero and one photons. Local oscillators used in the correlation measurement are distributed to two observers by co-propagating it in an orthogonal polarization mode. This method eliminates the need for interferometrical stability in the setup, consequently making it a robust and scalable method.

  1. Impact of Single-Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) and Positron Emission Tomography/Computed Tomography (PET/CT) in the Diagnosis of Traumatic Brain Injury (TBI): Case Report.

    Science.gov (United States)

    Molina-Vicenty, Irma L; Santiago-Sánchez, Michelaldemar; Vélez-Miró, Iván; Motta-Valencia, Keryl

    2016-09-01

    Traumatic brain injury (TBI) is defined as damage to the brain resulting from an external force. TBI, a global leading cause of death and disability, is associated with serious social, economic, and health problems. In cases of mild-to-moderate brain damage, conventional anatomical imaging modalities may or may not detect the cascade of metabolic changes that have occurred or are occurring at the intracellular level. Functional nuclear medicine imaging and neurophysiological parameters can be used to characterize brain damage, as the former provides direct visualization of brain function, even in the absence of overt behavioral manifestations or anatomical findings. We report the case of a 30-year-old Hispanic male veteran who, after 2 traumatic brain injury events, developed cognitive and neuropsychological problems with no clear etiology in the presence of negative computed tomography (CT) findings.

  2. Sub-megahertz linewidth single photon source

    Science.gov (United States)

    Rambach, Markus; Nikolova, Aleksandrina; Weinhold, Till J.; White, Andrew G.

    2016-12-01

    We report 100% duty cycle generation of sub-MHz single photon pairs at the rubidium D1 line using cavity-enhanced spontaneous parametric downconversion. The temporal intensity cross correlation function exhibits a bandwidth of 666 ±16 kHz for the single photons, an order of magnitude below the natural linewidth of the target transition. A half-wave plate inside our cavity helps to achieve triple resonance between pump, signal, and idler photon, reducing the bandwidth and simplifying the locking scheme. Additionally, stabilisation of the cavity to the pump frequency enables the 100% duty cycle. The quantum nature of the source is confirmed by the idler-triggered second-order autocorrelation function at τ =0 to be gs,s (2 )(0 ) = 0.016 ±0.002 for a heralding rate of 5 kHz. The generated photons are well-suited for storage in quantum memory schemes with sub-natural linewidths, such as gradient echo memories.

  3. Sub-megahertz linewidth single photon source

    Directory of Open Access Journals (Sweden)

    Markus Rambach

    2016-12-01

    Full Text Available We report 100% duty cycle generation of sub-MHz single photon pairs at the rubidium D1 line using cavity-enhanced spontaneous parametric downconversion. The temporal intensity cross correlation function exhibits a bandwidth of 666±16 kHz for the single photons, an order of magnitude below the natural linewidth of the target transition. A half-wave plate inside our cavity helps to achieve triple resonance between pump, signal, and idler photon, reducing the bandwidth and simplifying the locking scheme. Additionally, stabilisation of the cavity to the pump frequency enables the 100% duty cycle. The quantum nature of the source is confirmed by the idler-triggered second-order autocorrelation function at τ=0 to be gs,s(2(0= 0.016±0.002 for a heralding rate of 5 kHz. The generated photons are well-suited for storage in quantum memory schemes with sub-natural linewidths, such as gradient echo memories.

  4. Automated Characterization of Single-Photon Avalanche Photodiode

    Directory of Open Access Journals (Sweden)

    Aina Mardhiyah M. Ghazali

    2012-01-01

    Full Text Available We report an automated characterization of a single-photon detector based on commercial silicon avalanche photodiode (PerkinElmer C30902SH. The photodiode is characterized by I-V curves at different illumination levels (darkness, 10 pW and 10 µW, dark count rate and photon detection efficiency at different bias voltages. The automated characterization routine is implemented in C++ running on a Linux computer. ABSTRAK: Kami melaporkan pencirian pengesan foton tunggal secara automatik berdasarkan kepada diod foto runtuhan silikon (silicon avalanche photodiode (PerkinElmer C30902SH komersial. Pencirian  diod foto adalah berdasarkan kepada plot arus-voltan (I-V pada tahap pencahayaan yang berbeza (kelam - tanpa cahaya, 10pW, dan 10µW, kadar bacaan latar belakang, kecekapan pengesanan foton pada voltan picuan yang berbeza. Pengaturcaraan C++ digunakan di dalam rutin pencirian automatik melalui komputer dengan sistem pengendalian LINUX.KEYWORDS: avalanche photodiode (APD; single photon detector; photon counting; experiment automation

  5. Human Visual System as a Double-Slit Single Photon Interference Sensor: A Comparison between Modellistic and Biophysical Tests

    National Research Council Canada - National Science Library

    Pizzi, Rita; Wang, Rui; Rossetti, Danilo

    2016-01-01

    This paper describes a computational approach to the theoretical problems involved in the Young's single-photon double-slit experiment, focusing on a simulation of this experiment in the absence of measuring devices...

  6. Multimodal imaging analysis of single-photon emission computed tomography and magnetic resonance tomography for improving diagnosis of Parkinson's disease; Multimodale SPECT- und MRT-Bilddatenanalyse zur Verbesserung der Diagnostik des idiopathischen Parkinson-Syndroms

    Energy Technology Data Exchange (ETDEWEB)

    Barthel, H.; Georgi, P. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Mueller, U.; Waechter, T.; Murai, T. [Max-Planck-Inst. fuer Neuropsychologische Forschung, Leipzig (Germany); Slomka, P. [Universitaet West-Ontario, London (Canada). Abt. fuer Nuklearmedizin; Dannenberg, C.; Kahn, T. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie

    2000-10-01

    Parkinson's disease (PD) is characterized by a degeneration of nigrostriated dopaminergic neurons, which can be imaged with {sup 123}I-labeled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl) tropane ([{sup 123}I]{beta}-CIT) and single-photon emission computed tomography (SPECT). However, the quality of the region of interest (ROI) technique used for quantitative analysis of SPECT data is compromised by limited anatomical information in the images. We investigated whether the diagnosis of PD can be improved by combining the use of SPECT images with morphological image data from magnetic resonance imaging (MRI)/computed tomography (CT). We examined 27 patients (8 men, 19 women; aged 55{+-}13 years) with PD (Hoehn and Yahr stage 2.1{+-}0.8) by high-resolution [{sup 123}I]{beta}-CIT SPECT (185-200 MBq, Ceraspect camera). SPECT images were analyzed both by a unimodal technique (ROIs defined directly within the SPECT studies) and a multimodal technique (ROIs defined within individual MRI/CT studies and transferred to the corresponding interactively coregistered SPECT studies). [{sup 123}I]{beta}-CIT binding ratios (cerebellum as reference), which were obtained for heads of caudate nuclei (CA), putamina (PU), and global striatal structures were compared with clinical parameters. Differences between contra- and ipsilateral (related to symptom dominance) striatal [{sup 123}I]{beta}-CIT binding ratios proved to be larger in the multimodal ROI technique than in the unimodal approach (e.g., for PU: 1.2*** vs. 0.7**). Binding ratios obtained by the unimodal ROI technique were significantly correlated with those of the multimodal technique (e.g., for CA: y=0.97x+2.8; r=0.70; P<0.001). Concerning the correlations between SPECT data and clinical parameters, the significance levels in the multimodal ROI technique exceeded those of the unimodal technique, for example, for the correlation between CA and the UPDRS{sub com} subscore (r=-0.49* vs. -0.32). These results show that the

  7. Circuit electromechanics with single photon strong coupling

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Zheng-Yuan, E-mail: zyxue@scnu.edu.cn; Yang, Li-Na [Guangdong Provincial Key Laboratory of Quantum Engineering and Quantum Materials, and School of Physics and Telecommunication Engineering, South China Normal University, Guangzhou 510006 (China); Zhou, Jian, E-mail: jianzhou8627@163.com [Department of Electronic Communication Engineering, Anhui Xinhua University, Hefei 230088 (China); Guangdong Provincial Key Laboratory of Quantum Engineering and Quantum Materials, and School of Physics and Telecommunication Engineering, South China Normal University, Guangzhou 510006 (China)

    2015-07-13

    In circuit electromechanics, the coupling strength is usually very small. Here, replacing the capacitor in circuit electromechanics by a superconducting flux qubit, we show that the coupling among the qubit and the two resonators can induce effective electromechanical coupling which can attain the strong coupling regime at the single photon level with feasible experimental parameters. We use dispersive couplings among two resonators and the qubit while the qubit is also driven by an external classical field. These couplings form a three-wave mixing configuration among the three elements where the qubit degree of freedom can be adiabatically eliminated, and thus results in the enhanced coupling between the two resonators. Therefore, our work constitutes the first step towards studying quantum nonlinear effect in circuit electromechanics.

  8. Atomic metasurfaces for manipulation of single photons

    CERN Document Server

    Zhou, Ming; Kats, Mikhail; Yu, Zongfu

    2016-01-01

    Metasurfaces are an emerging platform for the manipulation of light on a two-dimensional plane. Existing metasurfaces comprise arrays of optical resonators such as plasmonic antennas or high-index nanoparticles. In this letter, we describe a new type of metasurface based on electronic transitions in two-level systems (TLSs). Specifically, we investigated a sheet of rubidium (Rb) atoms, whose energy levels can be tuned with structured illumination from a control laser, which enables dynamically tunable single-photon steering. These metasurface elements are lossless and orders of magnitude smaller than conventional optical resonators, which allows for the overlapping of multiple metasurfaces in a single plane, enabling multi-band operation. We demonstrate that atomic metasurfaces can be passive optical elements, and can also be utilized for beaming of spontaneously emitted photons. Though conceptually similar to conventional metasurfaces, the use of TLSs, which are inherently Fermionic, will lead to numerous ne...

  9. Purification of a single-photon nonlinearity

    Science.gov (United States)

    Snijders, H.; Frey, J. A.; Norman, J.; Bakker, M. P.; Langman, E. C.; Gossard, A.; Bowers, J. E.; van Exter, M. P.; Bouwmeester, D.; Löffler, W.

    2016-01-01

    Single photon nonlinearities based on a semiconductor quantum dot in an optical microcavity are a promising candidate for integrated optical quantum information processing nodes. In practice, however, the finite quantum dot lifetime and cavity-quantum dot coupling lead to reduced fidelity. Here we show that, with a nearly polarization degenerate microcavity in the weak coupling regime, polarization pre- and postselection can be used to restore high fidelity. The two orthogonally polarized transmission amplitudes interfere at the output polarizer; for special polarization angles, which depend only on the device cooperativity, this enables cancellation of light that did not interact with the quantum dot. With this, we can transform incident coherent light into a stream of strongly correlated photons with a second-order correlation value up to 40, larger than previous experimental results, even in the strong-coupling regime. This purification technique might also be useful to improve the fidelity of quantum dot based logic gates. PMID:27573361

  10. Single photon emission based on coherent state preparation

    Science.gov (United States)

    Ester, P.; Lackmann, L.; Michaelis de Vasconcellos, S.; Hübner, M. C.; Zrenner, A.; Bichler, M.

    2007-09-01

    The authors report here on deterministic single photon emission after coherent optical state preparation in the p-shell of a single InGaAs /GaAs quantum dot. In the approach, they use p-shell Rabi flopping followed by relaxation to the s-shell ground state with subsequent spontaneous single photon emission. Pulsed photon correlation experiments show complete suppression of the correlation peak at zero time delay and hence demonstrate clean single photon emission.

  11. Spin-based single-photon transistor, dynamic random access memory, diodes, and routers in semiconductors

    Science.gov (United States)

    Hu, C. Y.

    2016-12-01

    The realization of quantum computers and quantum Internet requires not only quantum gates and quantum memories, but also transistors at single-photon levels to control the flow of information encoded on single photons. Single-photon transistor (SPT) is an optical transistor in the quantum limit, which uses a single photon to open or block a photonic channel. In sharp contrast to all previous SPT proposals which are based on single-photon nonlinearities, here I present a design for a high-gain and high-speed (up to THz) SPT based on a linear optical effect: giant circular birefringence induced by a single spin in a double-sided optical microcavity. A gate photon sets the spin state via projective measurement and controls the light propagation in the optical channel. This spin-cavity transistor can be directly configured as diodes, routers, DRAM units, switches, modulators, etc. Due to the duality as quantum gate and transistor, the spin-cavity unit provides a solid-state platform ideal for future Internet: a mixture of all-optical Internet with quantum Internet.

  12. Spectral compression of single-photon-level laser pulse

    Science.gov (United States)

    Li, Yuanhua; Xiang, Tong; Nie, Yiyou; Sang, Minghuang; Chen, Xianfeng

    2017-01-01

    We experimentally demonstrate that the bandwidth of single photons laser pulse is compressed by a factor of 58 in a periodically poled lithium niobate (PPLN) waveguide chip. A positively chirped single photons laser pulse and a negatively chirped classical laser pulse are employed to produce a narrowband single photon pulse with new frequency through sum-frequency generation. In our experiment, the frequency and bandwidth of single photons at 1550 nm are simultaneously converted. Our results mark a critical step towards the realization of coherent photonic interface between quantum communication at 1550 nm and quantum memory in the near-visible window. PMID:28240245

  13. Generation and Detection of Infrared Single Photons and their Applications

    Institute of Scientific and Technical Information of China (English)

    ZENG He-ping; WU Guang; WU E; PAN Hai-feng; ZHOU Chun-yuan; WU E.,F.Treussart; J.-F.Roch

    2006-01-01

    Unbreakable secret communication has been a dream from ancient time.It is quantum physics that gives us hope to turn this wizardly dream into reality.The rapid development of quantum cryptography may put an end to the history of eavesdropping.This will be largely due to the advanced techniques related to single quanta,especially infrared single photons.In this paper,we report on our research works on single-photon control for quantum cryptography,ranging from single-photon generation to single-photon detection and their applications.

  14. Single photon in hierarchical architecture for physical reinforcement learning: Photon intelligence

    CERN Document Server

    Naruse, Makoto; Drezet, Aurélien; Huant, Serge; Hori, Hirokazu; Kim, Song-Ju

    2016-01-01

    Understanding and using natural processes for intelligent functionalities, referred to as natural intelligence, has recently attracted interest from a variety of fields, including post-silicon computing for artificial intelligence and decision making in the behavioural sciences. In a past study, we successfully used the wave-particle duality of single photons to solve the two-armed bandit problem, which constitutes the foundation of reinforcement learning and decision making. In this study, we propose and confirm a hierarchical architecture for single-photon-based reinforcement learning and decision making that verifies the scalability of the principle. Specifically, the four-armed bandit problem is solved given zero prior knowledge in a two-layer hierarchical architecture, where polarization is autonomously adapted in order to effect adequate decision making using single-photon measurements. In the hierarchical structure, the notion of layer-dependent decisions emerges. The optimal solutions in the coarse la...

  15. High Speed Travelling Wave Single-Photon Detectors With Near-Unity Quantum Efficiency

    CERN Document Server

    Pernice, W; Minaeva, O; Li, M; Goltsman, G N; Sergienko, A V; Tang, H X

    2011-01-01

    Ultrafast, high quantum efficiency single photon detectors are among the most sought-after elements in modern quantum optics and quantum communication. Close-to-unity photon detection efficiency is essential for scalable measurement-based quantum computation, quantum key distribution, and loophole-free Bell experiments. However, imperfect modal matching and finite photon absorption rates have usually limited the maximum attainable detection efficiency of single photon detectors. Here we demonstrate a superconducting nanowire detector atop nanophotonic waveguides and achieve single photon detection efficiency up to 94% at telecom wavelengths. Our detectors are fully embedded in a scalable, low loss silicon photonic circuit and provide ultrashort timing jitter of 18ps at multi-GHz detection rates. Exploiting this high temporal resolution we demonstrate ballistic photon transport in silicon ring resonators. The direct implementation of such a detector with high quantum efficiency, high detection speed and low ji...

  16. Single-photon imaging in complementary metal oxide semiconductor processes

    NARCIS (Netherlands)

    Charbon, E.

    2014-01-01

    This paper describes the basics of single-photon counting in complementary metal oxide semiconductors, through single-photon avalanche diodes (SPADs), and the making of miniaturized pixels with photon-counting capability based on SPADs. Some applications, which may take advantage of SPAD image senso

  17. Heralded single-photon ghost imaging

    CERN Document Server

    Aspden, Reuben S; Boyd, Robert W; Padgett, Miles J

    2013-01-01

    Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime these correlated light fields entail entangled photons produced by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which becomes worse as the number of pixels N in the image is increased. In this work we overcome such limitations by using a time-gated camera to record the single-photon events across the full scene. We produce high-contrast images in either the image plane or far-field of the down-conversion source, taking advantage of the EPR-like correlati...

  18. Characterization of APDs for single photon counting

    Energy Technology Data Exchange (ETDEWEB)

    Buglak, Wladimir; Hannen, Volker; Joehren, Raphael; Surholt, Martin; Vollbrecht, Jonas; Weinheimer, Christian [Muenster Univ. (Germany). Inst. fuer Kernphysik; Noertershaeuser, Wilfried [Mainz Univ. (Germany). Inst. fuer Kernchemie; GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Sanchez, Rodolfo [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany)

    2013-07-01

    For the SPECTRAP experiment at GSI, Germany, a detector system with single-photon counting capability operating in the wavelength region from 300 nm up to 1100 nm has been developed at the University of Muenster. The detector system utilises a silicon avalanche photo diode (APD) cooled to liquid nitrogen temperatures and operated near the breakdown voltage to obtain high gain values. While the current setup uses a 2 x 2 mm{sup 2} APD (type RMD S0223), it would be advantageous to have a larger active area for easier adjustment of the experiment optics. On the other hand a larger active area is accompanied by increased thermal noise which might harm the photon counting performance of the device. The characterization of a 8 x 8 mm{sup 2} APD (RMD S0814) is the subject of this poster. Furthermore a signal analysis software was developed to supress noise signals, e.g. caused by microphonic effects. The software processes signal waveforms recorded by a Flash ADC and should allow for a lower trigger threshold and thus higher detection efficiency.

  19. Indistinguishable single photons with real-time-programmable electronic triggering

    CERN Document Server

    Dada, Adetunmise C; Malein, Ralph N E; Koutroumanis, Antonios; Ma, Yong; Zajac, Joanna M; Lim, Ju Y; Song, Jin D; Gerardot, Brian D

    2016-01-01

    A key ingredient for quantum photonic technologies is an on-demand source of indistinguishable single photons. State-of-the-art indistinguishable-single-photon sources typically employ resonant excitation pulses with fixed repetition rates, creating a string of single photons with predetermined arrival times. However, in future applications, an independent electronic signal from a larger quantum circuit or network will trigger the generation of an indistinguishable photon. Further, operating the photon source up to the limit imposed by its lifetime is desirable. Here we report on the application of a true on-demand approach in which we can electronically trigger the precise arrival time of a single photon as well as control the excitation pulse duration. We investigate in detail the effect of finite duration of an excitation $\\pi$ pulse on the degree of photon antibunching. Finally, we demonstrate that highly indistinguishable single photons can be generated using this on-demand approach, enabling maximum fle...

  20. Single-photon absorber based on strongly interacting Rydberg atoms

    CERN Document Server

    Tresp, Christoph; Mirgorodskiy, Ivan; Gorniaczyk, Hannes; Paris-Mandoki, Asaf; Hofferberth, Sebastian

    2016-01-01

    Removing exactly one photon from an arbitrary input pulse is an elementary operation in quantum optics and enables applications in quantum information processing and quantum simulation. Here we demonstrate a deterministic single-photon absorber based on the saturation of an optically thick free-space medium by a single photon due to Rydberg blockade. Single-photon subtraction adds a new component to the Rydberg quantum optics toolbox, which already contains photonic logic building-blocks such as single-photon sources, switches, transistors, and conditional $\\pi$-phase shifts. Our approach is scalable to multiple cascaded absorbers, essential for preparation of non-classical light states for quantum information and metrology applications, and, in combination with the single-photon transistor, high-fidelity number-resolved photon detection.

  1. Single photon imaging at ultra-high resolution

    Science.gov (United States)

    Bellazzini, R.; Spandre, G.; Minuti, M.; Brez, A.; Baldini, L.; Latronico, L.; Omodei, N.; Sgrò, C.; Bregeon, J.; Razzano, M.; Pinchera, M.; Tremsin, A.; McPhate, J.; Vallerga, J. V.; Siegmund, O.

    2008-06-01

    We present a detection system capable of imaging both single photon/positive ion and multiple coincidence photons/positive ions with extremely high spatial resolution. In this detector the photoelectrons excited by the incoming photons are multiplied by microchannel plate(s) (MCP). The process of multiplication is spatially constrained within an MCP pore, which can be as small as 4 μm for commercially available MCPs. An electron cloud originated by a single photoelectron is then encoded by a pixellated custom analog ASIC consisting of 105 K charge sensitive pixels of 50 μm in size arranged on a hexagonal grid. Each pixel registers the charge with an accuracy of electrons rms. Computation of the event centroid from the readout charges results in an accurate event position. A large number of simultaneous photons spatially separated by ˜0.4 mm can be detected simultaneously allowing multiple coincidence operation for the experiments where a large number of incoming photons/positive ions have to be detected simultaneously. The experimental results prove that the spatial resolution of the readout system itself is ˜3 μm FWHM enabling detection resolution better than 6 μm for the small pore MCPs. An attractive feature of the detection system is its capability to register the timing of each incoming photon/positive ion (in single photon detection mode) or of the first incoming particle (for the multiple coincidence detection) with an accuracy of ˜130 ps FWHM. There is also virtually no dark count noise in the detection system making it suitable for low count rate applications.

  2. Effect of temperature and phonons on the spectral properties of a multi-level semiconductor quantum dot single-photon source

    DEFF Research Database (Denmark)

    Nielsen, Per Kær; Nielsen, Torben Roland; Lodahl, Peter;

    2009-01-01

    Since it was realized that efficient quantum computing can be performed using single photons and standard linear optics elements, immense international research activity has been aimed at developing semiconductor quantum dot (QD) single-photon sources (SPS). In order to optimise the design of SPS...

  3. Construction of human single-chain variable fragment antibodies of medullary thyroid carcinoma and single photon emission computed tomography/computed tomography imaging in tumor-bearing nude mice.

    Science.gov (United States)

    Liu, Qiong; Pang, Hua; Hu, Xiaoli; Li, Wenbo; Xi, Jimei; Xu, Lu; Zhou, Jing

    2016-01-01

    Medullary thyroid carcinoma (MTC) is a rare tumor of the endocrine system with poor prognosis as it exhibits high resistance against conventional therapy. Recent studies have shown that monoclonal antibodies labeled with radionuclide have become important agents for diagnosing tumors. To elucidate whether single-chain fragment of variable (scFv) antibody labeled with 131I isotope is a potential imaging agent for diagnosing MTC. A human scFv antibody library of MTC using phage display technique was constructed with a capacity of 3x10(5). The library was panned with thyroid epithelial cell lines and MTC cell lines (TT). Western blotting and enzyme-linked immunosorbent assay (ELISA) were used to identify the biological characteristics of the panned scFv. Methyl thiazolyl tetrazolium (MTT) assay was also used to explore the optimal concentration of the TT cell proliferation inhibition rate. They were categorized into TT, SW480 and control groups using phosphate-buffered saline. Western blotting showed that molecular weight of scFv was 28 kDa, cell ELISA showed that the absorbance of TT cell group was significantly increased (P=0.000??) vs. the other three groups, and MTT assay showed that the inhibition rate between the two cell lines was statistically significantly different (Psingle photon emission computed tomography. scFv rapidly and specifically target MTC cells, suggesting the potential of this antibody as an imaging agent for diagnosing MTC.

  4. Photon Statistics of Single-Photon Quantum States in Real Single Photon Detection

    Institute of Scientific and Technical Information of China (English)

    李刚; 李园; 王军民; 彭堃墀; 张天才

    2004-01-01

    @@ Single photon detection (SPD) with high quantum efficiency has been widely used for measurement of different quantum states with different photon distributions.Based on the direct single SPD and double-SPD of HBT configuration, we discuss the effect of a real SPD on the photon statistics measurement and it shows that the measured photon distributions for different quantum states are corrected in different forms.The results are confirmed by experiment with the strongly attenuated coherent light and thermal light.This system can be used to characterize the photon statistics of the fluorescence light from single atom or single molecular.

  5. Quantum Overloading Cryptography Using Single-Photon Nonlocality

    Institute of Scientific and Technical Information of China (English)

    TAN Yong-Gang; CAI Qing-Yu; SHI Ting-Yun

    2007-01-01

    @@ Using the single-photon nonlocality, we propose a quantum novel overloading cryptography scheme, in which a single photon carries two bits information in one-way quantum channel. Two commutative modes of the single photon, the polarization mode and the spatial mode, are used to encode secret information. Strict time windows are set to detect the impersonation attack. The spatial mode which denotes the existence of photons is noncommutative with the phase of the photon, so that our scheme is secure against photon-number-splitting attack. Our protocol may be secure against individual attack.

  6. Secure quantum dialogue based on single-photon

    Institute of Scientific and Technical Information of China (English)

    Ji Xin; Zhang Shou

    2006-01-01

    In this paper a quantum dialogue scheme is proposed by using N batches of single photons. The same secret message is encoded on each batch of single photons by the sender with two different unitary operations, and then the N batches of single photons are sent to the receiver. After eavesdropping check, the message is encoded on the one remaining batch by the receiver. It is shown that the intercept-and-resend attack and coupling auxiliary modes attack can be resisted more efficiently, because the photons are sent only once in our quantum dialogue scheme.

  7. Ultrabright single-photon source on diamond with electrical pumping at room and high temperatures

    Science.gov (United States)

    Fedyanin, D. Yu; Agio, M.

    2016-07-01

    The recently demonstrated electroluminescence of color centers in diamond makes them one of the best candidates for room temperature single-photon sources. However, the reported emission rates are far off what can be achieved by state-of-the-art electrically driven epitaxial quantum dots. Since the electroluminescence mechanism has not yet been elucidated, it is not clear to what extent the emission rate can be increased. Here we develop a theoretical framework to study single-photon emission from color centers in diamond under electrical pumping. The proposed model comprises electron and hole trapping and releasing, transitions between the ground and excited states of the color center as well as structural transformations of the center due to carrier trapping. It provides the possibility to predict both the photon emission rate and the wavelength of emitted photons. Self-consistent numerical simulations of the single-photon emitting diode based on the proposed model show that the photon emission rate can be as high as 100 kcounts s-1 at standard conditions. In contrast to most optoelectronic devices, the emission rate steadily increases with the device temperature achieving of more than 100 Mcount s-1 at 500 K, which is highly advantageous for practical applications. These results demonstrate the potential of color centers in diamond as electrically driven non-classical light emitters and provide a foundation for the design and development of single-photon sources for optical quantum computation and quantum communication networks operating at room and higher temperatures.

  8. 32-channel single photon counting module for ultrasensitive detection of DNA sequences

    Science.gov (United States)

    Gudkov, Georgiy; Dhulla, Vinit; Borodin, Anatoly; Gavrilov, Dmitri; Stepukhovich, Andrey; Tsupryk, Andrey; Gorbovitski, Boris; Gorfinkel, Vera

    2006-10-01

    We continue our work on the design and implementation of multi-channel single photon detection systems for highly sensitive detection of ultra-weak fluorescence signals, for high-performance, multi-lane DNA sequencing instruments. A fiberized, 32-channel single photon detection (SPD) module based on single photon avalanche diode (SPAD), model C30902S-DTC, from Perkin Elmer Optoelectronics (PKI) has been designed and implemented. Unavailability of high performance, large area SPAD arrays and our desire to design high performance photon counting systems drives us to use individual diodes. Slight modifications in our quenching circuit has doubled the linear range of our system from 1MHz to 2MHz, which is the upper limit for these devices and the maximum saturation count rate has increased to 14 MHz. The detector module comprises of a single board computer PC-104 that enables data visualization, recording, processing, and transfer. Very low dark count (300-1000 counts/s), robust, efficient, simple data collection and processing, ease of connectivity to any other application demanding similar requirements and similar performance results to the best commercially available single photon counting module (SPCM from PKI) are some of the features of this system.

  9. Heralded single photon absorption by a single atom

    CERN Document Server

    Piro, Nicolas; Schuck, Carsten; Almendros, Marc; Huwer, Jan; Ghosh, Joyee; Haase, Albrecht; Hennrich, Markus; Dubin, Francois; Eschner, Jürgen

    2010-01-01

    The emission and absorption of single photons by single atomic particles is a fundamental limit of matter-light interaction, manifesting its quantum mechanical nature. At the same time, as a controlled process it is a key enabling tool for quantum technologies, such as quantum optical information technology [1, 2] and quantum metrology [3, 4, 5, 6]. Controlling both emission and absorption will allow implementing quantum networking scenarios [1, 7, 8, 9], where photonic communication of quantum information is interfaced with its local processing in atoms. In studies of single-photon emission, recent progress includes control of the shape, bandwidth, frequency, and polarization of single-photon sources [10, 11, 12, 13, 14, 15, 16, 17], and the demonstration of atom-photon entanglement [18, 19, 20]. Controlled absorption of a single photon by a single atom is much less investigated; proposals exist but only very preliminary steps have been taken experimentally such as detecting the attenuation and phase shift o...

  10. Single-photon quantum router with multiple output ports.

    Science.gov (United States)

    Yan, Wei-Bin; Fan, Heng

    2014-04-28

    The routing capability is a requisite in quantum network. Although the quantum routing of signals has been investigated in various systems both in theory and experiment, the general form of quantum routing with many output terminals still needs to be explored. Here we propose a scheme to achieve the multi-channel quantum routing of the single photons in a waveguide-emitter system. The channels are composed by the waveguides and are connected by intermediate two-level emitters. By adjusting the intermediate emitters, the output channels of the input single photons can be controlled. This is demonstrated in the cases of one output channel, two output channels and the generic N output channels. The results show that the multi-channel quantum routing of single photons can be well achieved in the proposed system. This offers a scheme for the experimental realization of general quantum routing of single photons.

  11. Category theoretic analysis of single-photon decision maker

    CERN Document Server

    Kim, Makoto Naruse Song-Ju; Berthel, Martin; Drezet, Aurélien; Huant, Serge; Hori, Hirokazu

    2016-01-01

    Decision making is a vital function in the era of artificial intelligence; however, its physical realizations and their theoretical fundamentals are not yet known. In our former study [Sci. Rep. 5, 513253 (2015)], we demonstrated that single photons can be used to make decisions in uncertain, dynamically changing environments. The multi-armed bandit problem was successfully solved using the dual probabilistic and particle attributes of single photons. Herein, we present the category theoretic foundation of the single-photon-based decision making, including quantitative analysis that agrees well with the experimental results. The category theoretic model unveils complex interdependencies of the entities of the subject matter in the most simplified manner, including a dynamically changing environment. In particular, the octahedral structure in triangulated categories provides a clear understanding of the underlying mechanisms of the single-photon decision maker. This is the first demonstration of a category the...

  12. Continuous variable teleportation of single photon states (Proceedings version)

    OpenAIRE

    Ide, Toshiki; Hofmann, Holger F.; Kobayashi, Takayoshi; Furusawa, Akira

    2001-01-01

    We investigate the changes to a single photon state caused by the non-maximal entanglement in continuous variable quantum teleportation. It is shown that the teleportation measurement introduces field coherence in the output.

  13. Controllable single photon stimulation of retinal rod cells

    CERN Document Server

    Phan, Nam Mai; Bessarab, Dmitri A; Krivitsky, Leonid A

    2013-01-01

    Retinal rod cells are commonly assumed to be sensitive to single photons [1, 2, 3]. Light sources used in prior experiments exhibit unavoidable fluctuations in the number of emitted photons [4]. This leaves doubt about the exact number of photons used to stimulate the rod cell. In this letter, we interface rod cells of Xenopus laevis with a light source based on Spontaneous Parametric Down Conversion (SPDC) [5], which provides one photon at a time. Precise control of generation of single photons and directional delivery enables us to provide unambiguous proof of single photon sensitivity of rod cells without relying on the statistical assumptions. Quantum correlations between single photons in the SPDC enable us to determine quantum efficiency of the rod cell without pre-calibrated reference detectors [6, 7, 8]. These results provide the path for exploiting resources offered by quantum optics in generation and manipulation of light in visual studies. From a more general perspective, this method offers the ult...

  14. The analysis of the integral gated mode single photon detector

    Institute of Scientific and Technical Information of China (English)

    Wei Zheng-Jun; Li Kai-Zhen; Zhou Peng; Wang Jin-Dong; Liao Chang-Jun; Guo Jian-Ping; Liang Rui-Sheng; Liu Song-Hao

    2008-01-01

    This paper critically analyses and simulates the circuit configuration of the integral gated mode single photon detector which is proposed for eliminating the transient spikes problem of conventional gated mode single photon detector.The relationship between the values of the circuit elements and the effect of transient spikes cancellation has been obtained.With particular emphasis,the bias voltage of the avalanche photodiode and the output signal voltage of the integrator have been calculated.The obtained analysis results indicate that the output signal voltage of the integrator only relates to the total quantity of electricity of the avalanche charges by choosing the correct values of the circuit elements and integral time interval.These results can be used to optimize the performance of single photon detectors and provide guides for the design of single photon detectors.

  15. Correction of ultraviolet single photon counting image distortion

    Institute of Scientific and Technical Information of China (English)

    Xinghua Zhang; Baosheng Zhao; Zhenhua Miao; Wei Li; Xiangping Zhu; Yong'an Liu; Wei Zou

    2008-01-01

    Single photon counting imaging technology has been widely used in space environment detection, astronomy observation, nuclear physics, and ultraweak bioluminescence. However, the distortion of the single photon counting image will badly affect the measurement results. Therefore, the correction of distortion for single photon counting image is very significant. Ultraviolet single photon imaging system with wedge and strip anode is introduced and the influence factor leading to image distortion is analyzed. To correct original distorted image, three different image correction methods, namely, the physical correction, the global correction, and the local correction, are applied. In addition, two parameters, i.e, the position index and the linearity index, are defined to evaluate the performance of the three methods. The results suggest that the correction methods can improve the quality of the initial image without losing gray information of each counting light spot. And the local correction can provide the best visual inspections and performance evaluation among the three methods.

  16. Single photon laser altimeter data processing, analysis and experimental validation

    Science.gov (United States)

    Vacek, Michael; Peca, Marek; Michalek, Vojtech; Prochazka, Ivan

    2015-10-01

    Spaceborne laser altimeters are common instruments on-board the rendezvous spacecraft. This manuscript deals with the altimeters using a single photon approach, which belongs to the family of time-of-flight range measurements. Moreover, the single photon receiver part of the altimeter may be utilized as an Earth-to-spacecraft link enabling one-way ranging, time transfer and data transfer. The single photon altimeters evaluate actual altitude through the repetitive detections of single photons of the reflected laser pulses. We propose the single photon altimeter signal processing and data mining algorithm based on the Poisson statistic filter (histogram method) and the modified Kalman filter, providing all common altimetry products (altitude, slope, background photon flux and albedo). The Kalman filter is extended for the background noise filtering, the varying slope adaptation and the non-causal extension for an abrupt slope change. Moreover, the algorithm partially removes the major drawback of a single photon altitude reading, namely that the photon detection measurement statistics must be gathered. The developed algorithm deduces the actual altitude on the basis of a single photon detection; thus, being optimal in the sense that each detected signal photon carrying altitude information is tracked and no altitude information is lost. The algorithm was tested on the simulated datasets and partially cross-probed with the experimental data collected using the developed single photon altimeter breadboard based on the microchip laser with the pulse energy on the order of microjoule and the repetition rate of several kilohertz. We demonstrated that such an altimeter configuration may be utilized for landing or hovering a small body (asteroid, comet).

  17. HAPD time-resolution study under single-photon irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, S.; Akatsu, M.; Enari, Y.; Fujimoto, K.; Higashino, Y.; Hirose, M.; Hokuue, T.; Inami, K.; Ishikawa, A.; Matsumoto, T.; Misono, K.; Ohshima, T. E-mail: ohshima@hepl.phys.nagoya-u.ac.jp; Sugi, A.; Sugiyama, A.; Suzuki, S.; Tomoto, M

    2001-05-01

    We have studied the timing property of a Hybrid Avalanche PhotoDiode, Hamamatsu R7110U-07, and attained a time resolution of {sigma}{sub t}{approx}150 ps for single photons and {<=}100 ps for a few photons under certain conditions of photocathode voltage and diode reverse bias voltage. Relation between the achievable timing resolution and a multiplication gain is discussed, especially in realizing {sigma}{sub t}{<=}100 ps for single photons.

  18. Single-Photon Momentum Displacement in Resonator Array with Optomechanics

    Science.gov (United States)

    Tian, T.; Li, Q.; Zhou, Lan; Song, L. J.

    2016-10-01

    We present the single-photon scattering in a resonator array system with optomechanical by solving the Lippmann-Schwinger equation iteratively. Up to the first order of the radiation pressure interaction, the single-photon transport is formulated as a three-channel scattering process. We calculate the scattering currents in different channels and obtain the transmission spectrum which shows a momentum displacement effect.

  19. Optimal storage and retrieval of single-photon waveforms.

    Science.gov (United States)

    Zhou, Shuyu; Zhang, Shanchao; Liu, Chang; Chen, J F; Wen, Jianming; Loy, M M T; Wong, G K L; Du, Shengwang

    2012-10-22

    We report an experimental demonstration of optimal storage and retrieval of heralded single-photon wave packets using electromagnetically induced transparency (EIT) in cold atoms at a high optical depth. We obtain an optimal storage efficiency of (49 ± 3)% for single-photon waveforms with a temporal likeness of 96%. Our result brings the EIT quantum light-matter interface closer to practical quantum information applications.

  20. Quasi-secure quantum dialogue using single photons

    Institute of Scientific and Technical Information of China (English)

    YANG; YuGuang; WEN; QiaoYan

    2007-01-01

    A quasi-secure quantum dialogue protocol using single photons was proposed. Different from the previous entanglement-based protocols, the present protocol uses batches of single photons which run back and forth between the two parties. A round run for each photon makes the two parties each obtain a classical bit of information. So the efficiency of information transmission can be increased. The present scheme is practical and well within the present-day technology.

  1. III-Nitride high temperature single-photon sources

    Science.gov (United States)

    Bhattacharya, Pallab; Deshpande, Saniya; Frost, Thomas; Hazari, Arnab

    2015-03-01

    Nitride based GaN and InGaN quantum dots are excellent single-photon emitters at high temperature owing to their wide bandgap and large exciton binding energy [1-5]. In this work, two different molecular beam epitaxy (MBE) grown nanostructures have been investigated for single-photon emission: InGaN/GaN disk-in-nanowire and InGaN/GaN self-organized quantum dot. Single-photon emission under both optical and electrical excitation has been observed from a single InGaN quantum contained in a GaN nanowire p-n junction. We demonstrate electrically driven single-photon emission, with a g (2)(0) = 0.35, from a single InGaN quantum dot emitting in the green spectral range (λ=520 nm) up to 125 K. Additionally, a self-organized InGaN/GaN single quantum dot diode was grown and fabricated. Emission from a single quantum dot (λ=620 nm) shows single-photon emission with g(2)(0) = 0.29 at room temperature. On-demand single-photon emission by electrical pumping of the quantum dot at an excitation repetition rate of 200 MHz was demonstrated.

  2. A Single-Photon Subtractor for Multimode Quantum States

    Science.gov (United States)

    Ra, Young-Sik; Jacquard, Clément; Averchenko, Valentin; Roslund, Jonathan; Cai, Yin; Dufour, Adrien; Fabre, Claude; Treps, Nicolas

    2016-05-01

    In the last decade, single-photon subtraction has proved to be key operations in optical quantum information processing and quantum state engineering. Implementation of the photon subtraction has been based on linear optics and single-photon detection on single-mode resources. This technique, however, becomes unsuitable with multimode resources such as spectrally multimode squeezed states or continuous variables cluster states. We implement a single-photon subtractor for such multimode resources based on sum-frequency generation and single-photon detection. An input multimode quantum state interacts with a bright control beam whose spectrum has been engineered through ultrafast pulse-shaping. The multimode quantum state resulting from the single-photon subtractor is analyzed with multimode homodyne detection whose local oscillator spectrum is independently engineered. We characterize the single-photon subtractor via coherent-state quantum process tomography, which provides its mode-selectivity and subtraction modes. The ability to simultaneously control the state engineering and its detection ensures both flexibility and scalability in the production of highly entangled non-Gaussian quantum states.

  3. Prostate cancer and abdomino-pelvic masses with {sup 99m}Tc-HDP uptake. Contribution of the single photon emission computerized tomography guided by computerized tomography (SPECT/CT); Cancer de la prostate et masses abdominopelviennes fixant le {sup 99m}Tc-HDP. Apport de la tomographie d'emission monophotonique couplee a la tomodensitometrie (TEMP-TDM)

    Energy Technology Data Exchange (ETDEWEB)

    Granier, P.; Mourad, M. [Centre Hospitalier Antoine-Gayraud, Service de Medecine Nucleaire, 11 - Carcassonne (France)

    2009-06-15

    We report the case of a 63-year-old man, investigated for staging of a prostatic cancer, diagnosed by biopsy, following a rise in the prostatic specific antigen (P.S.A.) on a systematic assessment. The interrogation before examination revealed signs of beginning right crural neuropathy. The hydroxy-methylene diphosphonate technetium 99 m-labeled ({sup 99m}Tc-H.D.P.) whole-body bone scintigraphy highlighted two extraosseous uptake images, the first of moderated intensity in the right iliac area, the second milder, in the abdominal median area. Osseous metastases were not visualized. The single photon emission computerized tomography guided by computerized tomography (SPECT/CT) identified the median abdominal mass which corresponded to a bulky aneurysm of the under renal abdominal aorta. The right iliac mass could be accurately analyzed and differentiated from the various organs of the abdomino-pelvic cavity. Its lymphatic origin was hypothesized, but the diagnosis of lymphatic metastasis of the prostatic cancer was obtained by the pathologic examination of CT scan-guided biopsy. (authors)

  4. Combined single photon emission computerized tomography and conventional computerized tomography: Clinical value for the shoulder surgeons?

    Directory of Open Access Journals (Sweden)

    Michael T Hirschmann

    2011-01-01

    Full Text Available With the cases described, we strive to introduce single photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT to shoulder surgeons, illustrate the possible clinical value it may offer as new diagnostic radiologic modality, and discuss its limitations. SPECT/CT may facilitate the establishment of diagnosis, process of decision making, and further treatment for complex shoulder pathologies. Some of these advantages were highlighted in cases that are frequently seen in most shoulder clinics.

  5. Human Visual System as a Double-Slit Single Photon Interference Sensor: A Comparison between Modellistic and Biophysical Tests: e0147464

    National Research Council Canada - National Science Library

    Rita Pizzi; Rui Wang; Danilo Rossetti

    2016-01-01

      This paper describes a computational approach to the theoretical problems involved in the Young's single-photon double-slit experiment, focusing on a simulation of this experiment in the absence of measuring devices...

  6. Characterizing heralded single-photon sources with imperfect measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Razavi, M; Soellner, I; Bocquillon, E; Couteau, C; Laflamme, R; Weihs, G [Institute for Quantum Computing, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1 (Canada)], E-mail: mrazavi@iqc.ca

    2009-06-14

    Any characterization of a single-photon source is not complete without specifying its second-order degree of coherence, i.e., its g{sup (2)} function. An accurate measurement of such coherence functions commonly requires high-precision single-photon detectors, in whose absence only time-averaged measurements are possible. It is not clear, however, how the resulting time-averaged quantities can be used to properly characterize the source. In this paper, we investigate this issue for a heralded source of single photons that relies on continuous-wave parametric down-conversion. By accounting for major shortcomings of the source and the detectors-i.e., the multiple-photon emissions of the source, the time resolution of photodetectors and our chosen width of coincidence window-our theory enables us to infer the true source properties from imperfect measurements. Our theoretical results are corroborated by an experimental demonstration using a PPKTP crystal pumped by a blue laser that results in a single-photon generation rate about 1.2 millions per second per milliwatt of pump power. This work takes an important step towards the standardization of such heralded single-photon sources.

  7. Single photon sources with single semiconductor quantum dots

    Science.gov (United States)

    Shan, Guang-Cun; Yin, Zhang-Qi; Shek, Chan Hung; Huang, Wei

    2014-04-01

    In this contribution, we briefly recall the basic concepts of quantum optics and properties of semiconductor quantum dot (QD) which are necessary to the understanding of the physics of single-photon generation with single QDs. Firstly, we address the theory of quantum emitter-cavity system, the fluorescence and optical properties of semiconductor QDs, and the photon statistics as well as optical properties of the QDs. We then review the localization of single semiconductor QDs in quantum confined optical microcavity systems to achieve their overall optical properties and performances in terms of strong coupling regime, efficiency, directionality, and polarization control. Furthermore, we will discuss the recent progress on the fabrication of single photon sources, and various approaches for embedding single QDs into microcavities or photonic crystal nanocavities and show how to extend the wavelength range. We focus in particular on new generations of electrically driven QD single photon source leading to high repetition rates, strong coupling regime, and high collection efficiencies at elevated temperature operation. Besides, new developments of room temperature single photon emission in the strong coupling regime are reviewed. The generation of indistinguishable photons and remaining challenges for practical single-photon sources are also discussed.

  8. Fast time-domain measurements on telecom single photons

    Science.gov (United States)

    Allgaier, Markus; Vigh, Gesche; Ansari, Vahid; Eigner, Christof; Quiring, Viktor; Ricken, Raimund; Brecht, Benjamin; Silberhorn, Christine

    2017-09-01

    Direct measurements on the temporal envelope of quantum light are a challenging task and not many examples are known because most classical pulse characterisation methods do not work on the single-photon level. Knowledge of both spectrum and timing can, however, give insights on properties that cannot be determined by the spectral intensity alone. While temporal measurements on single photons on timescales of tens of picoseconds are possible with superconducting photon detectors, and picosecond measurements have been performed using streak cameras, there are no commercial single-photon sensitive devices with femtosecond resolution available. While time-domain sampling using sum-frequency generation has already been exploited for such a measurement, inefficient conversion has necessitated long integration times to build the temporal profile. We demonstrate a highly efficient waveguided sum-frequency generation process in Lithium Niobate to measure the temporal envelope of single photons with femtosecond resolution with short enough acquisition time to provide a live-view of the measurement. We demonstrate the measurement technique and combine it with spectral measurements using a dispersive-fibre time-of-flight spectrometer to determine upper and lower bounds for the spectral purity of heralded single photons. The approach complements the joint spectral intensity measurements as a measure on the purity can be given without knowledge of the spectral phase.

  9. Investigating and Improving Student Understanding of Quantum Mechanics in the Context of Single Photon Interference

    Science.gov (United States)

    Marshman, Emily; Singh, Chandralekha

    2017-01-01

    Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the…

  10. Conversion from Single Photon to Single Electron Spin Using Electrically Controllable Quantum Dots

    Science.gov (United States)

    Oiwa, Akira; Fujita, Takafumi; Kiyama, Haruki; Allison, Giles; Ludwig, Arne; Wieck, Andreas D.; Tarucha, Seigo

    2017-01-01

    Polarization is a fundamental property of light and could provide various solutions to the development of secure optical communications with high capacity and high speed. In particular, the coherent quantum state conversion between single photons and single electron spins is a prerequisite for long-distance quantum communications and distributed quantum computation. Electrically defined quantum dots have already been proven to be suitable for scalable solid state qubits by demonstrations of single-spin coherent manipulations and two-qubit gate operations. Thus, their capacity for quantum information technologies would be considerably extended by the achievement of entanglement between an electron spin in the quantum dots and a photon. In this review paper, we show the basic technologies for trapping single electrons generated by single photons in quantum dots and for detecting their spins using the Pauli effect with sensitive charge sensors.

  11. Deterministic reshaping of single-photon spectra using cross-phase modulation

    CERN Document Server

    Matsuda, Nobuyuki

    2016-01-01

    The frequency conversion of light has proved to be a crucial technology for communication, spectroscopy, imaging, and signal processing. In the quantum regime, it also offers great potential for realizing quantum networks incorporating disparate physical systems and quantum-enhanced information processing over a large computational space. The frequency conversion of quantum light, such as single photons, has been extensively investigated for the last two decades using all-optical frequency mixing, with the ultimate goal of realizing lossless and noiseless conversion. I demonstrate another route to this target using frequency conversion induced by cross-phase modulation in a dispersion-managed photonic crystal fiber. Owing to the deterministic and all-optical nature of the process, the lossless and low-noise spectral reshaping of a single-photon wave packet in the telecommunication band has been readily achieved with a modulation bandwidth as large as 0.4 THz. I further demonstrate that the scheme is applicabl...

  12. Bright and stable visible-spectrum single photon emitter in silicon carbide

    CERN Document Server

    Lienhard, Benjamin; Mouradian, Sara; Dolde, Florian; Tran, Toan Trong; Aharonovich, Igor; Englund, Dirk R

    2016-01-01

    Single photon sources are of paramount importance in quantum communication, quantum computation, and quantum metrology. In particular, there is great interest to realize scalable solid state platforms that can emit triggered photons on demand to achieve scalable nanophotonic networks. We report on a visible-spectrum single photon emitter in 4H-silicon carbide (SiC). The emitter is photostable at room- and low-temperature enabling photon counts per second (cps) in excess of 2$\\times$10$^6$ from unpatterned, bulk SiC. It exists in two orthogonally polarized states, which have parallel absorption and emission dipole orientations. Low temperature measurements reveal a narrow zero phonon line (linewidth $30~$% of the total photoluminescence spectrum.

  13. Economical quantum secure direct communication network with single photons

    Institute of Scientific and Technical Information of China (English)

    Deng Fu-Guo; Li Xi-Han; Li Chun-Yan; Zhou Ping; Zhou Hong-Yu

    2007-01-01

    In this paper a scheme for quantum secure direct communication (QSDC) network is proposed with a sequence of polarized single photons. The single photons are prepared originally in the same state |0> by the servers on the network,which will reduce the difficulty for the legitimate users to check eavesdropping largely. The users code the information on the single photons with two unitary operations which do not change their measuring bases. Some decoy photons,which are produced by operating the sample photons with a Hadamard, are used for preventing a potentially dishonest server from eavesdropping the quantum lines freely. This scheme is an economical one as it is the easiest way for QSDC network communication securely.

  14. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Science.gov (United States)

    Privitera, Simona; Tudisco, Salvatore; Lanzanò, Luca; Musumeci, Francesco; Pluchino, Alessandro; Scordino, Agata; Campisi, Angelo; Cosentino, Luigi; Finocchiaro, Paolo; Condorelli, Giovanni; Mazzillo, Massimo; Lombardo, Salvo; Sciacca, Emilio

    2008-01-01

    Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs). Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated. PMID:27873777

  15. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  16. Efficient Generation of Frequency-Multiplexed Entangled Single Photons

    Science.gov (United States)

    Qiu, Tian-Hui; Xie, Min

    2016-12-01

    We present two schemes to generate frequency-multiplexed entangled (FME) single photons by coherently mapping photonic entanglement into and out of a quantum memory based on Raman interactions. By splitting a single photon and performing subsequent state transfer, we separate the generation of entanglement and its frequency conversion, and find that the both progresses have the characteristic of inherent determinacy. Our theory can reproduce the prominent features of observed results including pulse shapes and the condition for deterministically generating the FME single photons. The schemes are suitable for the entangled photon pairs with a wider frequency range, and could be immune to the photon loss originating from cavity-mode damping, spontaneous emission, and the dephasing due to atomic thermal motion. The sources might have significant applications in wavelength-division-multiplexing quantum key distribution.

  17. Single-photon-level quantum memory at room temperature

    CERN Document Server

    Reim, K F; Lee, K C; Nunn, J; Langford, N K; Walmsley, I A

    2010-01-01

    Quantum memories capable of storing single photons are essential building blocks for quantum information processing, enabling the storage and transfer of quantum information over long distances. Devices operating at room temperature can be deployed on a large scale and integrated into existing photonic networks, but so far warm quantum memories have been susceptible to noise at the single photon level. This problem is circumvented in cold atomic ensembles, but these are bulky and technically complex. Here we demonstrate controllable, broadband and efficient storage and retrieval of weak coherent light pulses at the single-photon level in warm atomic caesium vapour using the far off-resonant Raman memory scheme. The unconditional noise floor is found to be low enough to operate the memory in the quantum regime at room temperature.

  18. Absolute calibration of fiber-coupled single-photon detector.

    Science.gov (United States)

    Lunghi, Tommaso; Korzh, Boris; Sanguinetti, Bruno; Zbinden, Hugo

    2014-07-28

    We show a setup for characterising the efficiency of a single-photon-detector absolutely and with a precision better than 1%. Since the setup does not rely on calibrated devices and can be implemented with standard-optic components, it can be realised in any laboratory. Our approach is based on an Erbium-Doped-Fiber-Amplifier (EDFA) radiometer as a primary measurement standard for optical power, and on an ultra-stable source of spontaneous emission. As a proof of principle, we characterise the efficiency of an InGaAs/InP single-photon detector. We verified the correctness of the characterisation with independent measurements. In particular, the measurement of the optical power made with the EDFA radiometer has been compared to that of the Federal Institute of Metrology using a transfer power meter. Our approach is suitable for frequent characterisations of high-efficient single-photon detectors.

  19. Absolute calibration of fiber-coupled single-photon detector

    CERN Document Server

    Lunghi, Tommaso; Sanguinetti, Bruno; Zbinden, Hugo

    2014-01-01

    We show a setup for characterising the efficiency of a single-photon-detector absolutely and with a precision better of 1%. Since the setup does not rely on calibrated devices and can be implemented with standard-optic components, it can be realised in any laboratory. Our approach is based on an Erbium-Doped-Fiber-Amplifier (EDFA) radiometer as a primary measurement standard for optical power, and on an ultra-stable source of spontaneous emission. As a proof of principle, we characterise the efficiency of an InGaAs/InP single-photon detector. We verified the correctness of the characterisation with independent measurements. In particular, the measurement of the optical power made with the EDFA radiometer has been compared to that of the Swiss Federal Office of Metrology using a transfer power meter. Our approach is suitable for frequent characterisations of high-efficient single-photon detectors.

  20. Video recording true single-photon double-slit interference

    Science.gov (United States)

    Aspden, Reuben S.; Padgett, Miles J.; Spalding, Gabriel C.

    2016-09-01

    Commercially available cameras do not have a low-enough dark noise to directly capture double-slit interference at the single photon level. In this work, camera noise levels are significantly reduced by activating the camera only when the presence of a photon has been detected by the independent detection of a time-correlated photon produced via parametric down-conversion. This triggering scheme provides the improvement required for direct video imaging of Young's double-slit experiment with single photons, allowing clarified versions of this foundational demonstration. We present video data of the evolving interference patterns. Also, we introduce variations on this experiment aimed at promoting discussion of the role spatial coherence plays in such a measurement, emphasizing complementary aspects of single-photon measurement and highlighting the roles of transverse position and momentum correlations between down-converted photons, including examples of "ghost" imaging and diffraction.

  1. A Bright Single Photon Source Based on a Diamond Nanowire

    CERN Document Server

    Babinec, T; Khan, M; Zhang, Y; Maze, J; Hemmer, P R; Loncar, M

    2009-01-01

    The development of a robust light source that emits one photon at a time is an outstanding challenge in quantum science and technology. Here, at the transition from many to single photon optical communication systems, fully quantum mechanical effects may be utilized to achieve new capabilities, most notably perfectly secure communication via quantum cryptography. Practical implementations place stringent requirements on the device properties, including fast and stable photon generation, efficient collection of photons, and room temperature operation. Single photon light emitting devices based on fluorescent dye molecules, quantum dots, nanowires, and carbon nanotube material systems have all been explored, but none have simultaneously demonstrated all criteria. Here, we describe the design, fabrication, and characterization of a bright source of single photons consisting of an individual Nitrogen-vacancy color center (NV center) in a diamond nanowire operating in ambient conditions. The nanowire plays a posit...

  2. Photonic wires and trumpets for ultrabright single photon sources

    DEFF Research Database (Denmark)

    Gérard, Jean-Michel; Claudon, Julien; Bleuse, Joël

    2013-01-01

    Photonic wires have recently demonstrated very attractive assets in the field of high-efficiency single photon sources. After presenting the basics of spontaneous emission control in photonic wires, we compare the two possible tapering strategies that can be applied to their output end so...... as to tailor their radiation diagram in the far-field. We highlight the novel “photonic trumpet” geometry, which provides a clean Gaussian beam, and is much less sensitive to fabrication imperfections than the more common needle-like taper geometry. S4Ps based on a single QD in a PW with integrated bottom...... mirror and tapered tip display jointly a record-high efficiency (0.75±0.1 photon per pulse) and excellent single photon purity. Beyond single photon sources, photonic wires and trumpets appear as a very attractive resource for solid-state quantum optics experiments....

  3. Investigation of Hamamatsu H8500 phototubes as single photon detectors

    CERN Document Server

    Hoek, M; Mirazita, M; Montgomery, R A; Orlandi, A; Pereira, S Anefalos; Pisano, S; Rossi, P; Viticchiè, A; Witchger, A

    2014-01-01

    We have investigated the response of a significant sample of Hamamatsu H8500 MultiAnode PhotoMultiplier Tubes (MAPMTs) as single photon detectors, in view of their use in a ring imaging Cherenkov counter for the CLAS12 spectrometer at the Thomas Jefferson National Accelerator Facility. For this, a laser working at 407.2nm wavelength was employed. The sample is divided equally into standard window type, with a spectral response in the visible light region, and UV-enhanced window type MAPMTs. The studies confirm the suitability of these MAPMTs for single photon detection in such a Cherenkov imaging application.

  4. Optimizing optical Bragg scattering for single-photon frequency conversion

    CERN Document Server

    Lefrancois, Simon; Eggleton, Benjamin J

    2014-01-01

    We develop a systematic theory for optimising single-photon frequency conversion using optical Bragg scattering. The efficiency and phase-matching conditions for the desired Bragg scattering conversion as well as spurious scattering and modulation instability are identified. We find that third-order dispersion can suppress unwanted processes, while dispersion above the fourth order limits the maximum conversion efficiency. We apply the optimisation conditions to frequency conversion in highly nonlinear fiber, silicon nitride waveguides and silicon nanowires. Efficient conversion is confirmed using full numerical simulations. These design rules will assist the development of efficient quantum frequency conversion between multicolour single photon sources for integration in complex quantum networks.

  5. Interferometric measurement of the helical mode of a single photon

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, E J; Coyle, L E; Johnson, E; Reschovsky, B J, E-mail: egalvez@colgate.edu [Department of Physics and Astronomy, Colgate University, 13 Oak Drive, Hamilton, NY 13346 (United States)

    2011-05-15

    We present measurements of the helical mode of single photons and do so by sending heralded photons through a Mach-Zehnder interferometer that prepares the light in a helical mode with topological charge one, and interferes it with itself in the fundamental non-helical mode. Masks placed after the interferometer were used to diagnose the amplitude and phase of the mode of the light. Auxiliary measurements verified that the light was in a non-classical state. The results are in good agreement with theory. The experiments demonstrate in a direct way that single photons carry the entire spatial helical-mode information.

  6. Single-photon heat conduction in electrical circuits

    CERN Document Server

    Jones, P J; Tan, K Y; Möttönen, M

    2011-01-01

    We study photonic heat conduction between two resistors coupled weakly to a single superconducting microwave cavity. At low enough temperature, the dominating part of the heat exchanged between the resistors is transmitted by single-photon excitations of the fundamental mode of the cavity. This manifestation of single-photon heat conduction should be experimentally observable with the current state of the art. Our scheme can possibly be utilized in remote interference-free temperature control of electric components and environment engineering for superconducting qubits coupled to cavities.

  7. Single-photon transistor in circuit quantum electrodynamics.

    Science.gov (United States)

    Neumeier, Lukas; Leib, Martin; Hartmann, Michael J

    2013-08-01

    We introduce a circuit quantum electrodynamical setup for a "single-photon" transistor. In our approach photons propagate in two open transmission lines that are coupled via two interacting transmon qubits. The interaction is such that no photons are exchanged between the two transmission lines but a single photon in one line can completely block or enable the propagation of photons in the other line. High on-off ratios can be achieved for feasible experimental parameters. Our approach is inherently scalable as all photon pulses can have the same pulse shape and carrier frequency such that output signals of one transistor can be input signals for a consecutive transistor.

  8. Using single photons to improve fiber optic communication systems

    Science.gov (United States)

    Pinto, Armando N.; Silva, Nuno A.; Almeida, Álvaro J.; Muga, Nelson J.

    2014-08-01

    We show how to generate, encode, transmit and detect single photons. By using single photons we can address two of the more challenging problems that communication engineers face nowadays: capacity and security. Indeed, by decreasing the number of photons used to encode each bit, we can efficiently explore the full capacity to carry information of optical fibers, and we can guarantee privacy at the physical layer. We present results for single and entangled photon generation. We encode information in the photons polarization and after transmission we retrieve that information. We discuss the impact of fiber birefringence on the photons polarization.

  9. Combustion study with synchrotron radiation single photon ionization technique

    Institute of Scientific and Technical Information of China (English)

    YANG Rui; WANG Jing; HUANG Chaoqun; YANG Bin; WEI Lixia; SHAN Xiaobin; SHENG Liusi; ZHANG Yunwu; QI Fei

    2005-01-01

    Here we report a combustion endstation at National Synchrotron Radiation Laboratory (NSRL) and some primary experimental results. Synchrotron radiation can provide the tunable vacuum ultraviolet (VUV) photon with the high intensity and the good collimation. VUV photoionization is a single-photon ionization process. Combined with molecular-beam mass spectrometry (MBMS), the VUV single-photon ionization can be applied to detect the combustion products, especially the intermediates and free radicals produced from combustion process. This method is proved to be a powerful tool for combustion study, which could be helpful for developing combustion kinetic models and understanding the mechanism of combustion reactions.

  10. Design and simulations of highly efficient single-photon sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; de Lasson, Jakob Rosenkrantz; Mørk, Jesper

    The realization of the highly-efficient single-photon source represents not only an experimental, but also a numerical challenge. We will present the theory of the waveguide QED approach, the design challenges and the current limitations. Additionally, the important numerical challenges in the si......The realization of the highly-efficient single-photon source represents not only an experimental, but also a numerical challenge. We will present the theory of the waveguide QED approach, the design challenges and the current limitations. Additionally, the important numerical challenges...

  11. Optical Quantum Computing

    National Research Council Canada - National Science Library

    Jeremy L. O'Brien

    2007-01-01

    In 2001, all-optical quantum computing became feasible with the discovery that scalable quantum computing is possible using only single-photon sources, linear optical elements, and single-photon detectors...

  12. Ultrafast Room-Temperature Single Photon Emission from Quantum Dots Coupled to Plasmonic Nanocavities.

    Science.gov (United States)

    Hoang, Thang B; Akselrod, Gleb M; Mikkelsen, Maiken H

    2016-01-13

    Efficient and bright single photon sources at room temperature are critical components for quantum information systems such as quantum key distribution, quantum state teleportation, and quantum computation. However, the intrinsic radiative lifetime of quantum emitters is typically ∼10 ns, which severely limits the maximum single photon emission rate and thus entanglement rates. Here, we demonstrate the regime of ultrafast spontaneous emission (∼10 ps) from a single quantum emitter coupled to a plasmonic nanocavity at room temperature. The nanocavity integrated with a single colloidal semiconductor quantum dot produces a 540-fold decrease in the emission lifetime and a simultaneous 1900-fold increase in the total emission intensity. At the same time, the nanocavity acts as a highly efficient optical antenna directing the emission into a single lobe normal to the surface. This plasmonic platform is a versatile geometry into which a variety of other quantum emitters, such as crystal color centers, can be integrated for directional, room-temperature single photon emission rates exceeding 80 GHz.

  13. On-demand semiconductor single-photon source with near-unity indistinguishability

    CERN Document Server

    He, Yu-Ming; Wei, Yu-Jia; Wu, Dian; Atatüre, Mete; Schneider, Christian; Höfling, Sven; Kamp, Martin; Lu, Chao-Yang; Pan, Jian-Wei

    2013-01-01

    Single photon sources based on semiconductor quantum dots offer distinct advantages for quantum information, including a scalable solid-state platform, ultrabrightness, and interconnectivity with matter qubits. A key prerequisite for their use in optical quantum computing and solid-state networks is a high level of efficiency and indistinguishability. Pulsed resonance fluorescence (RF) has been anticipated as the optimum condition for the deterministic generation of high-quality photons with vanishing effects of dephasing. Here, we generate pulsed RF single photons on demand from a single, microcavity-embedded quantum dot under s-shell excitation with 3-ps laser pulses. The pi-pulse excited RF photons have less than 0.3% background contributions and a vanishing two-photon emission probability. Non-postselective Hong-Ou-Mandel interference between two successively emitted photons is observed with a visibility of 0.97(2), comparable to trapped atoms and ions. Two single photons are further used to implement a h...

  14. A study of pile-up in integrated time-correlated single photon counting systems.

    Science.gov (United States)

    Arlt, Jochen; Tyndall, David; Rae, Bruce R; Li, David D-U; Richardson, Justin A; Henderson, Robert K

    2013-10-01

    Recent demonstration of highly integrated, solid-state, time-correlated single photon counting (TCSPC) systems in CMOS technology is set to provide significant increases in performance over existing bulky, expensive hardware. Arrays of single photon single photon avalanche diode (SPAD) detectors, timing channels, and signal processing can be integrated on a single silicon chip with a degree of parallelism and computational speed that is unattainable by discrete photomultiplier tube and photon counting card solutions. New multi-channel, multi-detector TCSPC sensor architectures with greatly enhanced throughput due to minimal detector transit (dead) time or timing channel dead time are now feasible. In this paper, we study the potential for future integrated, solid-state TCSPC sensors to exceed the photon pile-up limit through analytic formula and simulation. The results are validated using a 10% fill factor SPAD array and an 8-channel, 52 ps resolution time-to-digital conversion architecture with embedded lifetime estimation. It is demonstrated that pile-up insensitive acquisition is attainable at greater than 10 times the pulse repetition rate providing over 60 dB of extended dynamic range to the TCSPC technique. Our results predict future CMOS TCSPC sensors capable of live-cell transient observations in confocal scanning microscopy, improved resolution of near-infrared optical tomography systems, and fluorescence lifetime activated cell sorting.

  15. Unidirectional single-photon generation via matched zero-index metamaterials

    Science.gov (United States)

    Xu, Jingping; Song, Ge; Zhang, Zhenqing; Yang, Yaping; Chen, Hong; Zubairy, M. Suhail; Zhu, Shiyao

    2016-12-01

    We propose a scheme which can generate a highly directional single photon with almost 100% efficiency. Therefore we can get a useful single photon when it is required. An initial excited atom is placed inside a special Fabry-Pérot cavity whose walls consist of left-handed and zero-index metamaterials. The left-handed slabs work as a closed shell to avoid dissipation of the emitted photon, while the outer zero-index metamaterial slabs act as a special shutter which is transparent only for normal incidence, so that the photon emitted by the atom can only escape out of the cavity unidirectionally. Furthermore, we design the cavity with currently available metamaterials made of two-dimensional dielectric photonic crystals, and simulate the radiative field of an electric dipole to confirm our prediction. Differently from the previous proposal of single-photon sources which demanded complicated structure design and subtle mode analysis, our scheme is simple and robust for atomic position. This work has promising applications for quantum communication and optical quantum computing.

  16. Weaving single photon imaging into new drug development.

    Science.gov (United States)

    Mozley, P David

    2005-01-01

    The specific aim of this review is to assess the potential contribution of single photon emitting radiopharmaceutical technologies to new drug development. For each phase of therapeutic drug development, published literature was sought that shows single photon emitters can add value by quantifying pharmacokinetics, visualizing mechanisms of drug action, estimating therapeutic safety indices, or measuring dose-dependent pharmacodynamic effects. Not any published reports were found that describe using nuclear medicine techniques to help manage the progress of a new drug development program. As a consequence, most of the case in favor of weaving single photon imaging into the process had to be built on extrapolations from studies that showed feasibility post hoc. The strongest evidence of potential value was found for drug candidates that hope to influence diseases characterized by cell proliferation or cell death, particularly in the fields of oncology, cardiology, nephrology, and inflammation. Receptor occupancy studies were observed to occasionally offer unique advantages over analogous studies with positron emission tomography (PET). Enough hard data sets were found to justify the costs of using single photon imaging in a variety of new drug development paradigms.

  17. Quantum interference of independently generated telecom-band single photons

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Monika [Center for Photonic Communication and Computing, Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208-3112 (United States); Altepeter, Joseph B.; Huang, Yu-Ping; Oza, Neal N. [Center for Photonic Communication and Computing, Department of Electrical Engineering and Computer Science, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208-3118 (United States); Kumar, Prem [Center for Photonic Communication and Computing, Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208-3112, USA and Center for Photonic Communication and Computing, Department of Electrical Engineering (United States)

    2014-12-04

    We report on high-visibility quantum interference of independently generated telecom O-band (1310 nm) single photons using standard single-mode fibers. The experimental data are shown to agree well with the results of simulations using a comprehensive quantum multimode theory without the need for any fitting parameter.

  18. A silicon carbide room-temperature single-photon source

    Science.gov (United States)

    Castelletto, S.; Johnson, B. C.; Ivády, V.; Stavrias, N.; Umeda, T.; Gali, A.; Ohshima, T.

    2014-02-01

    Over the past few years, single-photon generation has been realized in numerous systems: single molecules, quantum dots, diamond colour centres and others. The generation and detection of single photons play a central role in the experimental foundation of quantum mechanics and measurement theory. An efficient and high-quality single-photon source is needed to implement quantum key distribution, quantum repeaters and photonic quantum information processing. Here we report the identification and formation of ultrabright, room-temperature, photostable single-photon sources in a device-friendly material, silicon carbide (SiC). The source is composed of an intrinsic defect, known as the carbon antisite-vacancy pair, created by carefully optimized electron irradiation and annealing of ultrapure SiC. An extreme brightness (2×106 counts s-1) resulting from polarization rules and a high quantum efficiency is obtained in the bulk without resorting to the use of a cavity or plasmonic structure. This may benefit future integrated quantum photonic devices.

  19. The physics of nanowire superconducting single-photon detectors

    NARCIS (Netherlands)

    Renema, Jelmer Jan

    2015-01-01

    We investigate the detection mechanism in superconducting single photon detectors via quantum detector tomography. We find that the detection event is caused by diffusion of quasiparticles from the absorption spot, combined with entrance of a vortex. Moreover, we investigate the behaviour of

  20. Waveguide-Coupled Superconducting Nanowire Single-Photon Detectors

    Science.gov (United States)

    Beyer, Andrew D.; Briggs, Ryan M.; Marsili, Francesco; Cohen, Justin D.; Meenehan, Sean M.; Painter, Oskar J.; Shaw, Matthew D.

    2015-01-01

    We have demonstrated WSi-based superconducting nanowire single-photon detectors coupled to SiNx waveguides with integrated ring resonators. This photonics platform enables the implementation of robust and efficient photon-counting detectors with fine spectral resolution near 1550 nm.

  1. Directional emission of single photons from small atomic samples

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; V. Poulsen, Uffe; Mølmer, Klaus

    2013-01-01

    We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state...

  2. Deterministic teleportation using single-photon entanglement as a resource

    DEFF Research Database (Denmark)

    Björk, Gunnar; Laghaout, Amine; Andersen, Ulrik L.

    2012-01-01

    We outline a proof that teleportation with a single particle is, in principle, just as reliable as with two particles. We thereby hope to dispel the skepticism surrounding single-photon entanglement as a valid resource in quantum information. A deterministic Bell-state analyzer is proposed which...

  3. High brightness single photon sources based on photonic wires

    DEFF Research Database (Denmark)

    Claudon, J.; Bleuse, J.; Bazin, M.

    2009-01-01

    We present a novel single-photon-source based on the emission of a semiconductor quantum dot embedded in a single-mode photonic wire. This geometry ensures a very large coupling (> 95%) of the spontaneous emission to the guided mode. Numerical simulations show that a photon collection efficiency...

  4. Potential of semiconductor nanowires for single photon sources

    NARCIS (Netherlands)

    Harmand, J.-C.; Liu, L.; Patriarche, G.; Tchernycheva, M.; Akopian, N.; Perinetti, U.; Zwiller, V.

    2009-01-01

    The catalyst-assisted growth of semiconductor nanowires heterostructures offers a very flexible way to design and fabricate single photon emitters. The nanowires can be positioned by organizing the catalyst prior to growth. Single quantum dots can be formed in the core of single nanowires which can

  5. Development of Subtraction Ictal Single-Photon Emission Computed Tomography Coregistered to MRI in Locating the Epileptogenic Focus of Intractable Epilepsy%SISCOM成像术在难治性癫痫致痫灶定位中的研究进展

    Institute of Scientific and Technical Information of China (English)

    金超岭; 王猛; 刘杰; 颜珏

    2015-01-01

    Subtraction ictal single-photon emission computed tomography coregistered to MRI (SISCOM) is a recently developed neuro-imaging method. As a multi-model imaging, SISCOM plays an important role in locating the epileptogenic focus of intractable epilepsy, which combines the advantages of anatomical imaging and functional imaging. This review focuses on the clinical effectiveness and inlfuence factors in locating the epileptogenic focus.%发作期单光子计算机断层减影与核磁共振融合成像术(SISCOM成像术)是一种新兴的神经影像学检查方法。SISCOM成像术作为一种多模态检查,结合了结构影像学和功能影像学的优势,在难治性癫痫致痫灶定位中表现出重要价值。本文主要对SISCOM在难治性癫痫致痫灶定位中的影响因素和临床价值做一综述。

  6. A single photon emission computed tomograph based on a limited dumber of detectors for fluid flow visualization; Tomographie d'emission gamma a partir d'un nombre limite de detecteurs appliquee a la visualisation d'ecoulements

    Energy Technology Data Exchange (ETDEWEB)

    Legoupil, S

    1999-07-01

    We present in this work a method for fluid flow visualization in a system using radioactive tracers. The method is based on single photon emission computed tomography techniques, applied to a limited number of discrete detectors. We propose in this work a method for the estimation of the transport matrix of photons, associated to the acquisition system.This method is based on the modelization of profiles acquired for a set of point sources located in the imaged volume. Monte Carlo simulations allow to separate scattered photons from those directly collected by the system. The influence of the energy tracer is exposed. The reconstruction method is based on the maximum likelihood - expectation maximization algorithm. An experimental device, based on 36 detectors was realised for the visualization of water circulation in a vessel. A video monitoring allows to visualize the dye water tracer. Dye and radioactive tracers are injected simultaneously in a water flow circulating in the vessel. Reconstructed and video images are compared. Quantitative and qualitative analysis show that fluid flow visualization is feasible with a limited number of detectors. This method can be applied for system involving circulations of fluids. (author)

  7. Multiple-Event, Single-Photon Counting Imaging Sensor

    Science.gov (United States)

    Zheng, Xinyu; Cunningham, Thomas J.; Sun, Chao; Wang, Kang L.

    2011-01-01

    The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

  8. Interfering Heralded Single Photons from Two Separate Silicon Nanowires Pumped at Different Wavelengths

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    2016-08-01

    Full Text Available Practical quantum photonic applications require on-demand single photon sources. As one possible solution, active temporal and wavelength multiplexing has been proposed to build an on-demand single photon source. In this scheme, heralded single photons are generated from different pump wavelengths in many temporal modes. However, the indistinguishability of these heralded single photons has not yet been experimentally confirmed. In this work, we achieve 88% ± 8% Hong–Ou–Mandel quantum interference visibility from heralded single photons generated from two separate silicon nanowires pumped at different wavelengths. This demonstrates that active temporal and wavelength multiplexing could generate indistinguishable heralded single photons.

  9. Clinical impact of (11)C-Pittsburgh compound-B positron emission tomography carried out in addition to magnetic resonance imaging and single-photon emission computed tomography on the diagnosis of Alzheimer's disease in patients with dementia and mild cognitive impairment.

    Science.gov (United States)

    Omachi, Yoshie; Ito, Kimiteru; Arima, Kunimasa; Matsuda, Hiroshi; Nakata, Yasuhiro; Sakata, Masuhiro; Sato, Noriko; Nakagome, Kazuyuki; Motohashi, Nobutaka

    2015-12-01

    The purpose of this study was to evaluate the clinical impact of addition of [(11)C]Pittsburgh compound-B positron emission tomography ((11)C-PiB PET) on routine clinical diagnosis of Alzheimer's disease (AD) dementia and mild cognitive impairment (MCI), and to assess diagnostic agreement between clinical criteria and research criteria of the National Institute on Aging-Alzheimer's Association. The diagnosis in 85 patients was made according to clinical criteria. Imaging examinations, including both magnetic resonance imaging and single-photon emission computed tomography/computed tomography to identify neuronal injury (NI), and (11)C-PiB PET to identify amyloid were performed, and all subjects were re-categorized according to the research criteria. Among 40 patients with probable AD dementia (ProAD), 37 were NI-positive, 29 were (11)C-PiB-positive, and 27 who were both NI- and (11C-PiB-positive were categorized as having 'ProAD dementia with a high level of evidence of the AD pathophysiological process'. Among 20 patients with possible AD dementia (PosAD), 17 were NI-positive, and six who were both NI- and (11)C-PiB-positive were categorized as having 'PosAD with evidence of the AD pathophysiological process'. Among 25 patients with MCI, 18 were NI-positive, 13 were (11)C-PiB-positive, and 10 who were both NI- and (11)C-PiB-positive were categorized as having 'MCI due to AD-high likelihood'. Diagnostic concordance between clinical criteria and research criteria may not be high in this study. (11)C-PiB PET may be of value in making the diagnosis of dementia and MCI in cases with high diagnostic uncertainty. © 2015 The Authors. Psychiatry and Clinical Neurosciences © 2015 Japanese Society of Psychiatry and Neurology.

  10. Very bright, near-infrared single photon emitters in diamond

    Directory of Open Access Journals (Sweden)

    D. W. M. Lau

    2013-09-01

    Full Text Available We demonstrate activation of bright diamond single photon emitters in the near infrared range by thermal annealing alone, i.e., without ion implantation. The activation is crucially dependent on the annealing ambient. The activation of the single photon emitters is only observed when the sample is annealed in forming gas (4% H2 in Ar above temperatures of 1000 °C. By contrast, no emitters are activated by annealing in vacuum, oxygen, argon or deuterium. The emitters activated by annealing in forming gas exhibit very bright emission in the 730-760 nm wavelength range and have linewidths of ∼1.5-2.5 nm at room temperature.

  11. Localization of Narrowband Single Photon Emitters in Nanodiamonds.

    Science.gov (United States)

    Bray, Kerem; Sandstrom, Russell; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-03-23

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bioimaging. However, current understanding of the origin of these emitters is extremely limited. In this work, we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond and are directly relevant to fabrication of novel quantum optics devices and sensors.

  12. Single-photon superradiance and radiation trapping by atomic shells

    Science.gov (United States)

    Svidzinsky, Anatoly A.; Li, Fu; Li, Hongyuan; Zhang, Xiwen; Ooi, C. H. Raymond; Scully, Marlan O.

    2016-04-01

    The collective nature of light emission by atomic ensembles yields fascinating effects such as superradiance and radiation trapping even at the single-photon level. Light emission is influenced by virtual transitions and the collective Lamb shift which yields peculiar features in temporal evolution of the atomic system. We study how two-dimensional atomic structures collectively emit a single photon. Namely, we consider spherical, cylindrical, and spheroidal shells with two-level atoms continuously distributed on the shell surface and find exact analytical solutions for eigenstates of such systems and their collective decay rates and frequency shifts. We identify states which undergo superradiant decay and states which are trapped and investigate how size and shape of the shell affects collective light emission. Our findings could be useful for quantum information storage and the design of optical switches.

  13. Localization of narrowband single photon emitters in nanodiamonds

    CERN Document Server

    Bray, Kerem; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-01-01

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bio-imaging. However, current understanding of the origin of these emitters is extremely limited. In this work we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond, and are directly relevant to fabrication of novel quantum optics devices and sensors.

  14. Entangling single photons from independently tuned semiconductor nanoemitters.

    Science.gov (United States)

    Sanaka, Kaoru; Pawlis, Alexander; Ladd, Thaddeus D; Sleiter, Darin J; Lischka, Klaus; Yamamoto, Yoshihisa

    2012-09-12

    Quantum communication systems based on nanoscale semiconductor devices is challenged by inhomogeneities from device to device. We address this challenge using ZnMgSe/ZnSe quantum-well nanostructures with local laser-based heating to tune the emission of single impurity-bound exciton emitters in two separate devices. The matched emission in combination with photon bunching enables quantum interference from the devices and allows the postselection of polarization-entangled single photons. The ability to entangle single photons emitted from nanometer-sized sources separated by macroscopic distances provides an essential step for a solid-state realization of a large-scale quantum optical network. This paves the way toward measurement-based entanglement generation between remote electron spins localized at macroscopically separated fluorine impurities.

  15. Hyperbolic Metamaterial Nano-Resonators Make Poor Single Photon Sources

    CERN Document Server

    Axelrod, Simon; Wong, Herman M K; Helmy, Amr S; Hughes, Stephen

    2016-01-01

    We study the optical properties of quantum dipole emitters coupled to hyperbolic metamaterial nano-resonators using a semi-analytical quasinormal mode approach. We show that coupling to metamaterial nano-resonators can lead to significant Purcell enhancements that are nearly an order of magnitude larger than those of plasmonic resonators with comparable geometry. However, the associated single photon output $\\beta$-factors are extremely low (around 10%), far smaller than those of comparable sized metallic resonators (70%). Using a quasinormal mode expansion of the photon Green function, we describe how the low $\\beta$-factors are due to increased Ohmic quenching arising from redshifted resonances, larger quality factors and stronger confinement of light within the metal. In contrast to current wisdom, these results suggest that hyperbolic metamaterial nano-structures make poor choices for single photon sources.

  16. Protecting single-photon entanglement with practical entanglement source

    Science.gov (United States)

    Zhou, Lan; Ou-Yang, Yang; Wang, Lei; Sheng, Yu-Bo

    2017-06-01

    Single-photon entanglement (SPE) is important for quantum communication and quantum information processing. However, SPE is sensitive to photon loss. In this paper, we discuss a linear optical amplification protocol for protecting SPE. Different from the previous protocols, we exploit the practical spontaneous parametric down-conversion (SPDC) source to realize the amplification, for the ideal entanglement source is unavailable in current quantum technology. Moreover, we prove that the amplification using the entanglement generated from SPDC source as auxiliary is better than the amplification assisted with single photons. The reason is that the vacuum state from SPDC source will not affect the amplification, so that it can be eliminated automatically. This protocol may be useful in future long-distance quantum communications.

  17. Advanced time-correlated single photon counting applications

    CERN Document Server

    Becker, Wolfgang

    2015-01-01

    This book is an attempt to bridge the gap between the instrumental principles of multi-dimensional time-correlated single photon counting (TCSPC) and typical applications of the technique. Written by an originator of the technique and by sucessful users, it covers the basic principles of the technique, its interaction with optical imaging methods and its application to a wide range of experimental tasks in life sciences and clinical research. The book is recommended for all users of time-resolved detection techniques in biology, bio-chemistry, spectroscopy of live systems, live cell microscopy, clinical imaging, spectroscopy of single molecules, and other applications that require the detection of low-level light signals at single-photon sensitivity and picosecond time resolution.

  18. Tunable single-photon frequency conversion in a Sagnac interferometer

    Science.gov (United States)

    Yan, Wei-Bin; Huang, Jin-Feng; Fan, Heng

    2013-12-01

    Quantum information carriers like photons might be manipulated, stored and transmitted in different quantum systems. It is important to integrate those systems efficiently. The capability of converting photons from one wavelength to another wavelength is a key requirement for combining the photons in telecommunications band for quantum transmission and the photons in near-visible band for quantum storage. Here, we investigate the tunable single-photon frequency conversion in the five-level emitter-Sagnac interferometer system. We show that the efficient single-photon conversion can be achieved in this scheme, at the same time, the frequencies of the input and output photons can be tuned in a large scale by controlling the frequencies and Rabi frequencies of the external driving fields. The realization of this scheme may lead to the efficient combination of quantum storage system with the quantum communication system.

  19. State-independent quantum contextuality with single photons

    CERN Document Server

    Amselem, Elias; Bourennane, Mohamed; Cabello, Adan

    2009-01-01

    Bell's theorem states that quantum predictions cannot be reproduced with hidden variable theories satisfying locality. The Kochen-Specker theorem states that quantum mechanics cannot be reproduced with non-contextual hidden variables. The result of a measurement is non-contextual when it is not affected by other compatible measurements being carried out on the same individual system. While Bell's theorem applies only to entangled states of composite systems, a distinguishing feature of the Kochen-Specker theorem is that it is valid for any quantum state, entangled or not, of any system, even for single systems. We present the first experimental state-independent violation of an inequality for non-contextual theories on single particles in the spirit of the original Kochen-Specker theorem. The tested inequality involves correlations between results of sequential compatible measurements on single photons. We show that 20 different single-photon states, ranging from states with maximal internal entanglement to m...

  20. Authenticated Quantum Key Distribution with Collective Detection using Single Photons

    Science.gov (United States)

    Huang, Wei; Xu, Bing-Jie; Duan, Ji-Tong; Liu, Bin; Su, Qi; He, Yuan-Hang; Jia, Heng-Yue

    2016-10-01

    We present two authenticated quantum key distribution (AQKD) protocols by utilizing the idea of collective (eavesdropping) detection. One is a two-party AQKD protocol, the other is a multiparty AQKD protocol with star network topology. In these protocols, the classical channels need not be assumed to be authenticated and the single photons are used as the quantum information carriers. To achieve mutual identity authentication and establish a random key in each of the proposed protocols, only one participant should be capable of preparing and measuring single photons, and the main quantum ability that the rest of the participants should have is just performing certain unitary operations. Security analysis shows that these protocols are free from various kinds of attacks, especially the impersonation attack and the man-in-the-middle (MITM) attack.

  1. Multi-group dynamic quantum secret sharing with single photons

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongwei [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Ma, Haiqiang, E-mail: hqma@bupt.edu.cn [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Wei, Kejin [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Yang, Xiuqing [School of Science, Beijing Jiaotong University, Beijing 100044 (China); Qu, Wenxiu; Dou, Tianqi; Chen, Yitian; Li, Ruixue; Zhu, Wu [School of Science and State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2016-07-15

    In this letter, we propose a novel scheme for the realization of single-photon dynamic quantum secret sharing between a boss and three dynamic agent groups. In our system, the boss can not only choose one of these three groups to share the secret with, but also can share two sets of independent keys with two groups without redistribution. Furthermore, the security of communication is enhanced by using a control mode. Compared with previous schemes, our scheme is more flexible and will contribute to a practical application. - Highlights: • A multi-group dynamic quantum secret sharing with single photons scheme is proposed. • Any one of the groups can be chosen to share secret through controlling the polarization of photons. • Two sets of keys can be shared simultaneously without redistribution.

  2. Video recording true single-photon double-slit interference

    CERN Document Server

    Aspden, Reuben S; Spalding, Gabriel C

    2016-01-01

    As normally used, no commercially available camera has a low-enough dark noise to directly produce video recordings of double-slit interference at the photon-by-photon level, because readout noise significantly contaminates or overwhelms the signal. In this work, noise levels are significantly reduced by turning on the camera only when the presence of a photon has been heralded by the arrival, at an independent detector, of a time-correlated photon produced via parametric down-conversion. This triggering scheme provides the improvement required for direct video imaging of Young's double-slit experiment with single photons, allowing clarified versions of this foundational demonstration. Further, we introduce variations on this experiment aimed at promoting discussion of the role spatial coherence plays in such a measurement. We also emphasize complementary aspects of single-photon measurement, where imaging yields (transverse) position information, while diffraction yields the transverse momentum, and highligh...

  3. Enhanced and directional single photon emission in hyperbolic metamaterials

    CERN Document Server

    Newman, Ward D; Jacob, Zubin

    2013-01-01

    We propose an approach to enhance and direct the spontaneous emission from isolated emitters embedded inside hyperbolic metamaterials into single photon beams. The approach rests on collective plasmonic Bloch modes of hyperbolic metamaterials which propagate in highly directional beams called quantum resonance cones. We propose a pumping scheme using the transparency window of the hyperbolic metamaterial that occurs near the topological transition. Finally, we address the challenge of outcoupling these broadband resonance cones into vacuum using a dielectric bullseye grating. We give a detailed analysis of quenching and design the metamaterial to have a huge Purcell factor in a broad bandwidth inspite of the losses in the metal. Our work should help motivate experiments in the development of single photon sources for broadband emitters such as nitrogen vacancy centers in diamond.

  4. Polarization Properties of Quantum-Dot-Based Single Photon Sources

    Institute of Scientific and Technical Information of China (English)

    HAN Shuo; HAO Zhi-Biao; LUO Yi

    2007-01-01

    Polarization properties of single photons emitted by optical pumping from a single quantum dot (QD) are studied by using a four-level system model. The model is capable of explaining the polarization uncertainty observed in single photon emission experiments. It is found that the dependence of photon emission efficiency and polarization visibility on pump power are opposite in general cases. By employing QDs with small size and strong carrier confinement, the photon polarization visibility under high pump power can be improved. In addition, embedding a QD into a well designed microcavity is also found to be favourable, whereas the trade-off between high polarization visibility and multi-photon emission is noted.

  5. Measurement of energetic single-photon production at LEP

    Science.gov (United States)

    Acciarri, M.; Adam, A.; Adriani, O.; Aguilar-Benitez, M.; Ahlen, S.; Alcaraz, J.; Aloisio, A.; Alverson, G.; Alviggi, M. G.; Ambrosi, G.; An, Q.; Anderhub, H.; Anderson, A. L.; Andreev, V. P.; Angelescu, T.; Antonov, L.; Antreasyan, D.; Alkhazov, G.; Arce, P.; Arefiev, A.; Azemoon, T.; Aziz, T.; Baba, P. V. K. S.; Bagnaia, P.; Bakken, J. A.; Baksay, L.; Ball, R. C.; Banerjee, S.; Banicz, K.; Barillère, R.; Barone, L.; Baschirotto, A.; Basile, M.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bencze, Gy. L.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B. L.; Biasini, M.; Biland, A.; Bilei, G. M.; Bizzarri, R.; Blaising, J. J.; Bobbink, G. J.; Bock, R.; Böhm, A.; Borgia, B.; Boucham, A.; Bourilkov, D.; Bourquin, M.; Boutigny, D.; Bouwens, B.; Brambilla, E.; Branson, J. G.; Brigljevic, V.; Brock, I. C.; Brooks, M.; Bujak, A.; Burger, J. D.; Burger, W. J.; Burgos, C.; Busenitz, J.; Buytenhuijs, A.; Bykov, A.; Cai, X. D.; Capell, M.; Cara Romeo, G.; Caria, M.; Carlino, G.; Cartacci, A. M.; Casaus, J.; Castello, R.; Cavallo, N.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y. H.; Chaturvedi, U. K.; Chemarin, M.; Chen, A.; Chen, C.; Chen, G.; Chen, G. M.; Chen, H. F.; Chen, H. S.; Chen, M.; Chiefari, G.; Chien, C. Y.; Choi, M. T.; Chung, S.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coan, T. E.; Cohn, H. O.; Coignet, G.; Colino, N.; Commichau, V.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Cui, X. T.; Cui, X. Y.; Dai, T. S.; D'Alessandro, R.; de Asmundis, R.; Degré, A.; Deiters, K.; Dénes, E.; Denes, P.; DeNotaristefani, F.; DiBitonto, D.; Diemoz, M.; Dimitrov, H. R.; Dionisi, C.; Dittmar, M.; Dorne, I.; Dova, M. T.; Drago, E.; Duchesneau, D.; Duhem, F.; Duinker, P.; Duran, I.; Dutta, S.; Easo, S.; El Mamouni, H.; Engler, A.; Eppling, F. J.; Erné, F. C.; Extermann, P.; Fabbretti, R.; Fabre, M.; Falciano, S.; Favara, A.; Fay, J.; Felcini, M.; Ferguson, T.; Fernandez, D.; Fernandez, G.; Ferroni, F.; Fesefeldt, H.; Fiandrini, E.; Field, J. H.; Filthaut, F.; Fisher, P. H.; Forconi, G.; Fredj, L.; Freudenreich, K.; Gailloud, M.; Galaktionov, Yu.; Gallo, E.; Ganguli, S. N.; Garcia-Abia, P.; Gau, S. S.; Gentile, S.; Gerald, J.; Gheordanescu, N.; Giagu, S.; Goldfarb, S.; Goldstein, J.; Gong, Z. F.; Gonzalez, E.; Gougas, A.; Goujon, D.; Gratta, G.; Gruenewald, M. W.; Gu, C.; Guanziroli, M.; Gupta, V. K.; Gurtu, A.; Gustafson, H. R.; Gutay, L. J.; Hartmann, B.; Hasan, A.; Hauschildt, D.; He, J. T.; Hebbeker, T.; Hebert, M.; Hervé, A.; Hilgers, K.; Hofer, H.; Hoorani, H.; Hou, S. R.; Hu, G.; Ille, B.; Ilyas, M. M.; Innocente, V.; Janssen, H.; Jin, B. N.; Jones, L. W.; de Jong, P.; Josa-Mutuberria, I.; Kasser, A.; Khan, R. A.; Kamyshkov, Yu.; Kapinos, P.; Kapustinsky, J. S.; Karyotakis, Y.; Kaur, M.; Khokhar, S.; Kienzle-Focacci, M. N.; Kim, D.; Kim, J. K.; Kim, S. C.; Kim, Y. G.; Kinnison, W. W.; Kirkby, A.; Kirkby, D.; Kirkby, J.; Kirsch, S.; Kittel, W.; Klimentov, A.; König, A. C.; Koffeman, E.; Kornadt, O.; Koutsenko, V.; Koulbardis, A.; Kraemer, R. W.; Kramer, T.; Krastev, V. R.; Krenz, W.; Kuijten, H.; Kunin, A.; Ladron de Guevara, P.; Landi, G.; Lanzano, S.; Laurikainen, P.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, D. M.; Lee, J. S.; Lee, K. Y.; Leedom, I.; Leggett, C.; Le Goff, J. M.; Leiste, R.; Lenti, M.; Leonardi, E.; Levtchenko, P.; Li, C.; Lieb, E.; Lin, W. T.; Linde, F. L.; Lindemann, B.; Lista, L.; Liu, Y.; Lohmann, W.; Longo, E.; Lu, W.; Lu, Y. S.; Lubbers, J. M.; Lübelsmeyer, K.; Luci, C.; Luckey, D.; Ludovici, L.; Luminari, L.; Lustermann, W.; Ma, W. G.; MacDermott, M.; Maity, M.; Malgeri, L.; Malik, R.; Malinin, A.; Maña, C.; Mangla, S.; Maolinbay, M.; Marchesini, P.; Marin, A.; Martin, J. P.; Marzano, F.; Massaro, G. G. G.; Mazumdar, K.; McMahon, T.; McNally, D.; Mele, S.; Merk, M.; Merola, L.; Meschini, M.; Metzger, W. J.; Mi, Y.; Mihul, A.; Mills, G. B.; Mir, Y.; Mirabelli, G.; Mnich, J.; Möller, M.; Monaco, V.; Monteleoni, B.; Morand, R.; Morganti, S.; Moulai, N. E.; Mount, R.; Müller, S.; Nagy, E.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niaz, M. A.; Nippe, A.; Nowak, H.; Organtini, G.; Ostonen, R.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Pascale, G.; Passaleva, G.; Patricelli, S.; Paul, T.; Pauluzzi, M.; Paus, C.; Pauss, F.; Pei, Y. J.; Pensotti, S.; Perret-Gallix, D.; Pevsner, A.; Piccolo, D.; Pieri, M.; Pinto, J. C.; Piroué, P. A.; Pistolesi, E.; Plasil, F.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Produit, N.; Qian, J. M.; Qureshi, K. N.; Raghavan, R.; Rahal-Callot, G.; Rancoita, P. G.; Rattaggi, M.; Raven, G.; Razis, P.; Read, K.; Redaelli, M.; Ren, D.; Ren, Z.; Rescigno, M.; Reucroft, S.; Ricker, A.; Riemann, S.; Riemers, B. C.; Riles, K.; Rind, O.; Rizvi, H. A.; Ro, S.; Robohm, A.; Rodriguez, F. J.; Roe, B. P.; Röhner, M.; Röhner, S.; Romero, L.; Rosier-Lees, S.; Rosmalen, R.; Rosselet, Ph.; van Rossum, W.; Roth, S.; Rubbia, A.; Rubio, J. A.; Rykaczewski, H.; Salicio, J.; Salicio, J. M.; Sanchez, E.; Sanders, G. S.; Santocchia, A.; Sarakinos, M. E.; Sarkar, S.; Sartorelli, G.; Sassowsky, M.; Sauvage, G.; Schäfer, C.; Schegelsky, V.; Schmitz, D.; Schmitz, P.; Schneegans, M.; Scholz, N.; Schopper, H.; Schotanus, D. J.; Shotkin, S.; Schreiber, H. J.; Shukla, J.; Schulte, R.; Schultze, K.; Schwenke, J.; Schwering, G.; Sciacca, C.; Sehgal, R.; Seiler, P. G.; Sens, J. C.; Servoli, L.; Sheer, I.; Shevchenko, S.; Shi, X. R.; Shumilov, E.; Shoutko, V.; Son, D.; Sopczak, A.; Soulimov, V.; Spartiotis, C.; Spickermann, T.; Spillantini, P.; Steuer, M.; Stickland, D. P.; Sticozzi, F.; Stone, H.; Strauch, K.; Sudhakar, K.; Sultanov, G.; Sun, L. Z.; Susinno, G. F.; Suter, H.; Swain, J. D.; Syed, A. A.; Tang, X. W.; Taylor, L.; Timellini, R.; Ting, Samuel C. C.; Ting, S. M.; Toker, O.; Tonutti, M.; Tonwar, S. C.; Tóth, J.; Trowitzsch, G.; Tsaregorodtsev, A.; Tsipolitis, G.; Tully, C.; Ulbricht, J.; Urbán, L.; Uwer, U.; Valente, E.; Van de Walle, R. T.; Vetlitsky, I.; Viertel, G.; Vikas, P.; Vikas, U.; Vivargent, M.; Vogel, H.; Vogt, H.; Vorobiev, I.; Vorobyov, A. A.; Vorobyov, An. A.; Vuilleumier, L.; Wadhwa, M.; Wallraff, W.; Wang, J. C.; Wang, X. L.; Wang, Y. F.; Wang, Z. M.; Weber, A.; Weill, R.; Willmott, C.; Wittgenstein, F.; Wright, D.; Wu, S. X.; Wynhoff, S.; Xu, Z. Z.; Yang, B. Z.; Yang, C. G.; Yang, G.; Yao, X. Y.; Ye, C. H.; Ye, J. B.; Ye, Q.; Yeh, S. C.; You, J. M.; Yunus, N.; Yzerman, M.; Zaccardelli, C.; Zemp, P.; Zeng, M.; Zeng, Y.; Zhang, D. H.; Zhang, Z. P.; Zhou, B.; Zhou, G. J.; Zhou, J. F.; Zhu, R. Y.; Zichichi, A.; van der Zwaan, B. C. C.

    1995-02-01

    We describe the sample of energetic single-photon events ( Eγ > 15 GeV) collected by L3 in the 1991-1993 LEP runs. The event distributions agree with expectations from the Standard Model. The data are used to constrain the ZZ γ coupling and to set an upper limit of 4.1 × 10 -6, μB (90% C.L.) on the the magnetic moment of the τ neutrino.

  6. Single photon generation by pulsed excitation of a single dipole

    CERN Document Server

    Brouri, R; Poizat, J P; Grangier, P; Brouri, Rosa; Beveratos, Alexios; Poizat, Jean-Philippe; Grangier, Philippe

    2000-01-01

    The fluorescence of a single dipole excited by an intense light pulse can lead to the generation of another light pulse containing a single photon. The influence of the duration and energy of the excitation pulse on the number of photons in the fluorescence pulse is studied. The case of a two-level dipole with strongly damped coherences is considered. The presence of a metastable state leading to shelving is also investigated.

  7. Single photon detection with self-quenching multiplication

    Science.gov (United States)

    Zheng, Xinyu (Inventor); Cunningham, Thomas J. (Inventor); Pain, Bedabrata (Inventor)

    2011-01-01

    A photoelectronic device and an avalanche self-quenching process for a photoelectronic device are described. The photoelectronic device comprises a nanoscale semiconductor multiplication region and a nanoscale doped semiconductor quenching structure including a depletion region and an undepletion region. The photoelectronic device can act as a single photon detector or a single carrier multiplier. The avalanche self-quenching process allows electrical field reduction in the multiplication region by movement of the multiplication carriers, thus quenching the avalanche.

  8. Deterministic teleportation using single-photon entanglement as a resource

    CERN Document Server

    Björk, Gunnar; Andersen, Ulrik L

    2011-01-01

    We outline a proof that teleportation with a single particle is in principle just as reliable as with two particles. We thereby hope to dispel the skepticism surrounding single-photon entanglement as a valid resource in quantum information. A deterministic Bell state analyzer is proposed which uses only classical resources, namely coherent states, a Kerr non-linearity, and a two-level atom.

  9. Superconducting single-photon detectors for integrated quantum optics

    Energy Technology Data Exchange (ETDEWEB)

    Kahl, Oliver

    2016-01-29

    This thesis reports on the implementation and characterization of a fully integrated single-photon detector. Several detector circuits are realized and it is shown that the detectors exhibit supreme detection performance over a wide optical spectrum. The detectors' scalability is showcased by the parallel operation of multiple detectors within a single integrated circuit. These demonstrations are essential for future developments in integrated quantum optics.

  10. A search for single photon events in neutrino interactions

    Science.gov (United States)

    Kullenberg, C. T.; Mishra, S. R.; Dimmery, D.; Tian, X. C.; Autiero, D.; Gninenko, S.; Rubbia, A.; Alekhin, S.; Astier, P.; Baldisseri, A.; Baldo-Ceolin, M.; Banner, M.; Bassompierre, G.; Benslama, K.; Besson, N.; Bird, I.; Blumenfeld, B.; Bobisut, F.; Bouchez, J.; Boyd, S.; Bueno, A.; Bunyatov, S.; Camilleri, L.; Cardini, A.; Cattaneo, P. W.; Cavasinni, V.; Cervera-Villanueva, A.; Challis, R.; Chukanov, A.; Collazuol, G.; Conforto, G.; Conta, C.; Contalbrigo, M.; Cousins, R.; Degaudenzi, H.; De Santo, A.; Del Prete, T.; Di Lella, L.; do Couto e Silva, E.; Dumarchez, J.; Ellis, M.; Feldman, G. J.; Ferrari, R.; Ferrère, D.; Flaminio, V.; Fraternali, M.; Gaillard, J.-M.; Gangler, E.; Geiser, A.; Geppert, D.; Gibin, D.; Godley, A.; Gomez-Cadenas, J.-J.; Gosset, J.; Gößling, C.; Gouanère, M.; Grant, A.; Graziani, G.; Guglielmi, A.; Hagner, C.; Hernando, J.; Hurst, P.; Hyett, N.; Iacopini, E.; Joseph, C.; Juget, F.; Kent, N.; Klimov, O.; Kokkonen, J.; Kovzelev, A.; Krasnoperov, A.; Kim, J. J.; Kirsanov, M.; Kulagin, S.; Lacaprara, S.; Lachaud, C.; Lakić, B.; Lanza, A.; La Rotonda, L.; Laveder, M.; Letessier-Selvon, A.; Levy, J.-M.; Ling, J.; Linssen, L.; Ljubičić, A.; Long, J.; Lupi, A.; Lyubushkin, V.; Marchionni, A.; Martelli, F.; Méchain, X.; Mendiburu, J.-P.; Meyer, J.-P.; Mezzetto, M.; Moorhead, G. F.; Naumov, D.; Nédélec, P.; Nefedov, Yu.; Nguyen-Mau, C.; Orestano, D.; Pastore, F.; Peak, L. S.; Pennacchio, E.; Pessard, H.; Petti, R.; Placci, A.; Polesello, G.; Pollmann, D.; Polyarush, A.; Poulsen, C.; Popov, B.; Rebuffi, L.; Rico, J.; Riemann, P.; Roda, C.; Salvatore, F.; Samoylov, O.; Schahmaneche, K.; Schmidt, B.; Schmidt, T.; Sconza, A.; Scott, A. M.; Seaton, M. B.; Sevior, M.; Sillou, D.; Soler, F. J. P.; Sozzi, G.; Steele, D.; Stiegler, U.; Stipčević, M.; Stolarczyk, Th.; Tareb-Reyes, M.; Taylor, G. N.; Tereshchenko, V.; Toropin, A.; Touchard, A.-M.; Tovey, S. N.; Tran, M.-T.; Tsesmelis, E.; Ulrichs, J.; Vacavant, L.; Valdata-Nappi, M.; Valuev, V.; Vannucci, F.; Varvell, K. E.; Veltri, M.; Vercesi, V.; Vidal-Sitjes, G.; Vieira, J.-M.; Vinogradova, T.; Weber, F. V.; Weisse, T.; Wilson, F. F.; Winton, L. J.; Wu, Q.; Yabsley, B. D.; Zaccone, H.; Zuber, K.; Zuccon, P.

    2012-01-01

    We present a search for neutrino induced events containing a single, exclusive photon using data from the NOMAD experiment at the CERN SPS where the average energy of the neutrino flux is ≃ 25 GeV. The search is motivated by an excess of electron-like events in the 200-475 MeV energy region as reported by the MiniBooNE experiment. In NOMAD, photons are identified via their conversion to e+e- in an active target embedded in a magnetic field. The background to the single photon signal is dominated by the asymmetric decay of neutral pions produced either in a coherent neutrino-nucleus interaction, or in a neutrino-nucleon neutral current deep inelastic scattering, or in an interaction occurring outside the fiducial volume. All three backgrounds are determined in situ using control data samples prior to opening the 'signal-box'. In the signal region, we observe 155 events with a predicted background of 129.2 ± 8.5 ± 3.3. We interpret this as null evidence for excess of single photon events, and set a limit. Assuming that the hypothetical single photon has a momentum distribution similar to that of a photon from the coherent π0 decay, the measurement yields an upper limit on single photon events, < 4.0 ×10-4 per νμ charged current event. Narrowing the search to events where the photon is approximately collinear with the incident neutrino, we observe 78 events with a predicted background of 76.6 ± 4.9 ± 1.9 yielding a more stringent upper limit, < 1.6 ×10-4 per νμ charged current event.

  11. Heterodyne spectroscopy with superconducting single-photon detector

    Science.gov (United States)

    Lobanov, Yu. V.; Shcherbatenko, M. L.; Semenov, A. V.; Kovalyuk, V. V.; Korneev, A. A.; Goltsman, G. N.

    2016-12-01

    We demonstrate successful operation of a Superconducting Single Photon Detector (SSPD) as the core element in a heterodyne receiver. Irradiating the SSPD by both a local oscillator power and signal power simultaneously, we observed beat signal at the intermediate frequency of a few MHz. Gain bandwidth was found to coincide with the detector single pulse width, where the latter depends on the detector kinetic inductance, determined by the superconducting nanowire length.

  12. Advanced active quenching circuits for single-photon avalanche photodiodes

    Science.gov (United States)

    Stipčević, M.; Christensen, B. G.; Kwiat, P. G.; Gauthier, D. J.

    2016-05-01

    Commercial photon-counting modules, often based on actively quenched solid-state avalanche photodiode sensors, are used in wide variety of applications. Manufacturers characterize their detectors by specifying a small set of parameters, such as detection efficiency, dead time, dark counts rate, afterpulsing probability and single photon arrival time resolution (jitter), however they usually do not specify the conditions under which these parameters are constant or present a sufficient description. In this work, we present an in-depth analysis of the active quenching process and identify intrinsic limitations and engineering challenges. Based on that, we investigate the range of validity of the typical parameters used by two commercial detectors. We identify an additional set of imperfections that must be specified in order to sufficiently characterize the behavior of single-photon counting detectors in realistic applications. The additional imperfections include rate-dependence of the dead time, jitter, detection delay shift, and "twilighting." Also, the temporal distribution of afterpulsing and various artifacts of the electronics are important. We find that these additional non-ideal behaviors can lead to unexpected effects or strong deterioration of the system's performance. Specifically, we discuss implications of these new findings in a few applications in which single-photon detectors play a major role: the security of a quantum cryptographic protocol, the quality of single-photon-based random number generators and a few other applications. Finally, we describe an example of an optimized avalanche quenching circuit for a high-rate quantum key distribution system based on time-bin entangled photons.

  13. Single-photon ultrashort-lived radionuclides: symposium proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Paras, P.; Thiessen, J.W. (eds.)

    1985-01-01

    The purpose was to define the current role and state-of-the-art regarding the development, clinical applications, and usefulness of generator-produced single-photon ultrashort-lived radionuclides (SPUSLR's) and to predict their future impact on medicine. Special emphasis was placed on the generator production of iridium-191, gold-195, and krypton-81. This report contains expanded summaries of the included papers. (ACR)

  14. Single-photon superradiance from a quantum dot

    DEFF Research Database (Denmark)

    Tighineanu, Petru; Daveau, Raphaël Sura; Lehmann, Tau Bernstorff

    2016-01-01

    We report on the observation of single-photon superradiance from an exciton in a semiconductor quantum dot. The confinement by the quantum dot is strong enough for it to mimic a two-level atom, yet sufficiently weak to ensure superradiance. The electrostatic interaction between the electron...... temperature of our cryostat and may lead to oscillator strengths above 1000 from a single quantum emitter at optical frequencies....

  15. Heterodyne spectroscopy with superconducting single-photon detector

    Directory of Open Access Journals (Sweden)

    Lobanov Yu.V.

    2017-01-01

    Full Text Available We demonstrate successful operation of a Superconducting Single Photon Detector (SSPD as the core element in a heterodyne receiver. Irradiating the SSPD by both a local oscillator power and signal power simultaneously, we observed beat signal at the intermediate frequency of a few MHz. Gain bandwidth was found to coincide with the detector single pulse width, where the latter depends on the detector kinetic inductance, determined by the superconducting nanowire length.

  16. EXPLORING THE REGIONAL CEREBRAL BLOOD FLOW IN A PATIENT WITH ANOREXIA NERVOSA USING 99mTc-ECD SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY%神经性厌食99mTc-ECD局部脑血流变化初探

    Institute of Scientific and Technical Information of China (English)

    金珏; 马莹华; 唐一源; 冯洪波; 于庆宝; 张晔; 杜雪梅; 张延军

    2007-01-01

    神经性厌食(Anorexia Nervosa,AN)是一种病因未明的心理行为综合症,社会文化及生物学因素间的交互作用被认为是该病的病因,脑成像体现出一些病理相关改变,但国内尚未见针对此病的成像报道.为给临床辅助诊断AN提供依据,采用经济、易获得的脑功能显像技术--单光子发射计算机断层显像(Single Photon Emission Computed Tomography,SPECT),扫描3位典型青年女性AN患者的大脑.通过统计参数图(Statistical Parametric Mapping,SPM2),基于体素的局部脑血流灌注分析,与25名正常青年女性脑图相比较发现,患者的前扣带和前额内侧、双侧额叶背外侧、后顶叶、颞叶中上部和小脑血流灌注降低,下丘脑、双侧颞叶中下部血流灌注增高,可能与神经递质回路有关,提示社会学因素可能只是该病的诱因,而生物学人格易感性才是该病的主要原因,同时说明SPECT脑血流成像有助于AN的临床辅助诊断.

  17. Single-photon sources for quantum technologies - Results of the joint research project SIQUTE

    DEFF Research Database (Denmark)

    Kück, S.; López, M.; Rodiek, B.

    2017-01-01

    In this presentation, the results of the joint research project “Single-Photon Sources for Quantum Technologies” (SIQUTE) [1] will be presented. The focus will be on the development of absolutely characterized single-photon sources, on the realization of an efficient waveguide-based single-photon...

  18. All-optical tailoring of single-photon spectra in a quantum-dot microcavity system

    CERN Document Server

    Breddermann, Dominik; Binder, Rolf; Zrenner, Artur; Schumacher, Stefan

    2016-01-01

    Semiconductor quantum-dot cavity systems are promising sources for solid-state based on-demand generation of single photons for quantum communication. Commonly, the spectral characteristics of the emitted single photon are fixed by system properties such as electronic transition energies and spectral properties of the cavity. In the present work we study single-photon generation from the quantum-dot biexciton through a partly stimulated non-degenerate two-photon emission. We show that frequency and linewidth of the single photon can be fully controlled by the stimulating laser pulse, ultimately allowing for efficient all-optical spectral shaping of the single photon.

  19. Reading boundless error-free bits using a single photon

    Science.gov (United States)

    Guha, Saikat; Shapiro, Jeffrey H.

    2013-06-01

    We address the problem of how efficiently information can be encoded into and read out reliably from a passive reflective surface that encodes classical data by modulating the amplitude and phase of incident light. We show that nature imposes no fundamental upper limit to the number of bits that can be read per expended probe photon and demonstrate the quantum-information-theoretic trade-offs between the photon efficiency (bits per photon) and the encoding efficiency (bits per pixel) of optical reading. We show that with a coherent-state (ideal laser) source, an on-off (amplitude-modulation) pixel encoding, and shot-noise-limited direct detection (an overly optimistic model for commercial CD and DVD drives), the highest photon efficiency achievable in principle is about 0.5 bits read per transmitted photon. We then show that a coherent-state probe can read unlimited bits per photon when the receiver is allowed to make joint (inseparable) measurements on the reflected light from a large block of phase-modulated memory pixels. Finally, we show an example of a spatially entangled nonclassical light probe and a receiver design—constructible using a single-photon source, beam splitters, and single-photon detectors—that can in principle read any number of error-free bits of information. The probe is a single photon prepared in a uniform coherent superposition of multiple orthogonal spatial modes, i.e., a W state. The code and joint-detection receiver complexity required by a coherent-state transmitter to achieve comparable photon efficiency performance is shown to be much higher in comparison to that required by the W-state transceiver, although this advantage rapidly disappears with increasing loss in the system.

  20. Ultrabright and efficient single-photon generation based on nitrogen-vacancy centres in nanodiamonds on a solid immersion lens

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Tim; Gaedeke, Friedemann; Banholzer, Moritz Julian; Benson, Oliver, E-mail: tim.schroeder@physik.hu-berlin.de [Humboldt-Universitaet zu Berlin, Institut fuer Physik, AG Nano Optics Newtonstrasse 15, 12489 Berlin (Germany)

    2011-05-15

    Single photons are fundamental elements for quantum information technologies such as quantum cryptography, quantum information storage and optical quantum computing. Colour centres in diamond have proven to be stable single-photon sources and thus essential components for reliable and integrated quantum information technology. A key requirement for such applications is a large photon flux and a high efficiency. Paying tribute to various attempts to maximize the single-photon flux, we show that collection efficiencies of photons from colour centres can be increased with a rather simple experimental setup. To do so, we spin-coated nanodiamonds containing single nitrogen-vacancy (N-V) colour centres on the flat surface of a ZrO{sub 2} solid immersion lens. We found stable single-photon count rates of up to 853 kcts s{sup -1} at saturation under continuous wave excitation while having access to more than 100 defect centres with count rates from 400 to 500 kcts s{sup -1}. For a blinking defect centre, we found count rates up to 2.4 Mcts s{sup -1} for time intervals of several tens of seconds. It seems to be a general feature that very high rates are accompanied by blinking behaviour. The overall collection efficiency of our setup of up to 4.2% is the highest yet reported for N-V defect centres in diamond. Under pulsed excitation of a stable emitter of 10 MHz, 2.2% of all pulses caused a click on the detector adding to 221 kcts s{sup -1} thus, opening the way towards diamond-based on-demand single-photon sources for quantum applications.

  1. Characterization of parallel superconducting nanowire single photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ejrnaes, M; Casaburi, A; Pagano, S; Cristiano, R [CNR-Istituto di Cibernetica ' E Caianiello' , 80078 Pozzuoli (Namibia) (Italy); Quaranta, O; Marchetti, S [Dipartimento di Fisica ' E R Caianiello' , Universita di Salerno, 84081 Baronissi (Italy); Gaggero, A; Mattioli, F; Leoni, R [CNR-Istituto di Fotonica e Nanotecnologie, 00156 Roma (Italy)

    2009-05-15

    Superconducting nanowire single photon detectors (SNSPDs) have been realized using an innovative parallel wire configuration. This configuration allows, at the same time, a large detection area and a fast response, with the additional advantage of large signal amplitudes. The detectors have been thoroughly characterized in terms of signal properties (amplitude, risetime and falltime), detector operation (latching and not latching) and quantum efficiency (at 850 nm). It has been shown that the parallel SNSPD is able to provide significantly higher maximum count rates for large area SNSPDs than meandered SNSPDs. Through a proper parallel wire configuration the increase in maximum count rate can be obtained without latching problems.

  2. Improved photon counting efficiency calibration using superconducting single photon detectors

    Science.gov (United States)

    Gan, Haiyong; Xu, Nan; Li, Jianwei; Sun, Ruoduan; Feng, Guojin; Wang, Yanfei; Ma, Chong; Lin, Yandong; Zhang, Labao; Kang, Lin; Chen, Jian; Wu, Peiheng

    2015-10-01

    The quantum efficiency of photon counters can be measured with standard uncertainty below 1% level using correlated photon pairs generated through spontaneous parametric down-conversion process. Normally a laser in UV, blue or green wavelength range with sufficient photon energy is applied to produce energy and momentum conserved photon pairs in two channels with desired wavelengths for calibration. One channel is used as the heralding trigger, and the other is used for the calibration of the detector under test. A superconducting nanowire single photon detector with advantages such as high photon counting speed (optical spectroscopy, super resolution microscopy, deep space observation, and so on.

  3. Inhomogeneous critical current in nanowire superconducting single-photon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gaudio, R., E-mail: r.gaudio@tue.nl; Hoog, K. P. M. op ' t; Zhou, Z.; Sahin, D.; Fiore, A. [COBRA Research Institute, Eindhoven University of Technology, P.O. Box 513, NL-5600MB Eindhoven (Netherlands)

    2014-12-01

    A superconducting thin film with uniform properties is the key to realize nanowire superconducting single-photon detectors (SSPDs) with high performance and high yield. To investigate the uniformity of NbN films, we introduce and characterize simple detectors consisting of short nanowires with length ranging from 100 nm to 15 μm. Our nanowires, contrary to meander SSPDs, allow probing the homogeneity of NbN at the nanoscale. Experimental results, endorsed by a microscopic model, show the strongly inhomogeneous nature of NbN films on the sub-100 nm scale.

  4. Efficient room-temperature source of polarized single photons

    Science.gov (United States)

    Lukishova, Svetlana G.; Boyd, Robert W.; Stroud, Carlos R.

    2007-08-07

    An efficient technique for producing deterministically polarized single photons uses liquid-crystal hosts of either monomeric or oligomeric/polymeric form to preferentially align the single emitters for maximum excitation efficiency. Deterministic molecular alignment also provides deterministically polarized output photons; using planar-aligned cholesteric liquid crystal hosts as 1-D photonic-band-gap microcavities tunable to the emitter fluorescence band to increase source efficiency, using liquid crystal technology to prevent emitter bleaching. Emitters comprise soluble dyes, inorganic nanocrystals or trivalent rare-earth chelates.

  5. High bit rate germanium single photon detectors for 1310nm

    Science.gov (United States)

    Seamons, J. A.; Carroll, M. S.

    2008-04-01

    There is increasing interest in development of high speed, low noise and readily fieldable near infrared (NIR) single photon detectors. InGaAs/InP Avalanche photodiodes (APD) operated in Geiger mode (GM) are a leading choice for NIR due to their preeminence in optical networking. After-pulsing is, however, a primary challenge to operating InGaAs/InP single photon detectors at high frequencies1. After-pulsing is the effect of charge being released from traps that trigger false ("dark") counts. To overcome this problem, hold-off times between detection windows are used to allow the traps to discharge to suppress after-pulsing. The hold-off time represents, however, an upper limit on detection frequency that shows degradation beginning at frequencies of ~100 kHz in InGaAs/InP. Alternatively, germanium (Ge) single photon avalanche photodiodes (SPAD) have been reported to have more than an order of magnitude smaller charge trap densities than InGaAs/InP SPADs2, which allowed them to be successfully operated with passive quenching2 (i.e., no gated hold off times necessary), which is not possible with InGaAs/InP SPADs, indicating a much weaker dark count dependence on hold-off time consistent with fewer charge traps. Despite these encouraging results suggesting a possible higher operating frequency limit for Ge SPADs, little has been reported on Ge SPAD performance at high frequencies presumably because previous work with Ge SPADs has been discouraged by a strong demand to work at 1550 nm. NIR SPADs require cooling, which in the case of Ge SPADs dramatically reduces the quantum efficiency of the Ge at 1550 nm. Recently, however, advantages to working at 1310 nm have been suggested which combined with a need to increase quantum bit rates for quantum key distribution (QKD) motivates examination of Ge detectors performance at very high detection rates where InGaAs/InP does not perform as well. Presented in this paper are measurements of a commercially available Ge APD

  6. Environment-induced entanglement with a single photon

    CERN Document Server

    Hor-Meyll, Malena; Borges, Carolina; Aragão, Adriano; Huguenin, José Augusto; Khoury, Antonio; Davidovich, Luiz; 10.1103/PhysRevA.80.042327

    2009-01-01

    We propose an all-optical setup, which couples different degrees of freedom of a single photon, to investigate entanglement generation by a common environment. The two qubits are represented by the photon polarization and Hermite-Gauss transverse modes, while the environment corresponds to the photon path. For an initially two-qubit separable state, the increase of entanglement is analyzed, as the probability of an environment-induced transition ranges from zero to one. An entanglement witness that is invariant throughout the evolution of the system yields a direct measurement of the concurrence of the two-qubit state.

  7. High performance guided-wave asynchronous heralded single photon source

    OpenAIRE

    Alibart, Olivier; Ostrowsky, Daniel Barry; Baldi, Pascal; Tanzilli, Sébastien

    2005-01-01

    International audience; We report on a guided wave heralded photon source based on the creation of non-degenerate photon pairs by spontaneous parametric down conversion in a Periodically Poled Lithium Niobate waveguide. Using the signal photon at 1310 nm as a trigger, a gated detection process permits announcing the arrival of single photons at 1550 nm at the output of a single mode optical fiber with a high probability of 0.38. At the same time the multi-photon emission probability is reduce...

  8. Secure authentication of classical messages with single photons

    Institute of Scientific and Technical Information of China (English)

    Wang Tian-Yin; Wen Qiao-Yan; Zhu Fu-Chen

    2009-01-01

    This paper proposes a scheme for secure authentication of classical messages with single photons and a hashed function.The security analysis of this scheme is also given,which shows that anyone cannot forge valid message authentication codes (MACs).In addition,the lengths of the authentication key and the MACs are invariable and shorter,in comparison with those presented authentication schemes.Moreover,quantum data storage and entanglement are not required in this scheme.Therefore,this scheme is more efficient and economical.

  9. Deterministic Single-Phonon Source Triggered by a Single Photon

    CERN Document Server

    Söllner, Immo; Lodahl, Peter

    2016-01-01

    We propose a scheme that enables the deterministic generation of single phonons at GHz frequencies triggered by single photons in the near infrared. This process is mediated by a quantum dot embedded on-chip in an opto-mechanical circuit, which allows for the simultaneous control of the relevant photonic and phononic frequencies. We devise new opto-mechanical circuit elements that constitute the necessary building blocks for the proposed scheme and are readily implementable within the current state-of-the-art of nano-fabrication. This will open new avenues for implementing quantum functionalities based on phonons as an on-chip quantum bus.

  10. Optimised quantum hacking of superconducting nanowire single-photon detectors

    Science.gov (United States)

    Tanner, Michael G.; Makarov, Vadim; Hadfield, Robert H.

    2014-03-01

    We explore bright-light control of superconducting nanowire single-photon detectors (SNSPDs) in the shunted configuration (a practical measure to avoid latching). In an experiment, we simulate an illumination pattern the SNSPD would receive in a typical quantum key distribution system under hacking attack. We show that it effectively blinds and controls the SNSPD. The transient blinding illumination lasts for a fraction of a microsecond and produces several deterministic fake clicks during this time. This attack does not lead to elevated timing jitter in the spoofed output pulse, and hence does not introduce significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  11. Nanofabrication of Plasmonic Circuits Containing Single Photon Sources

    DEFF Research Database (Denmark)

    Siampour Ashkavandi, Hamidreza; Kumar, Shailesh; Bozhevolnyi, Sergey I.

    2017-01-01

    -photon emitters, using electron-beam lithography of hydrogen silsesquioxane (HSQ) resist on silver-coated silicon substrates. A propagation length of 20 ± 5 μm for the NV single-photon emission is measured with DLSPPWs. A 5-fold enhancement in the total decay rate, and 58% coupling efficiency to the DLSPPW mode...... is achieved, indicating significant mode confinement. Finally, we demonstrate routing of single plasmons with DLSPPW-based directional couplers, revealing the potential of our approach for on-chip realization of quantum optical networks....

  12. Optimised quantum hacking of superconducting nanowire single-photon detectors

    CERN Document Server

    Tanner, Michael G; Hadfield, Robert H

    2013-01-01

    We explore optimised control of superconducting nanowire single-photon detectors (SNSPDs) through bright illumination. We consider the behaviour of the SNSPD in the shunted configuration (a practical measure to avoid latching) in long-running quantum key distribution experiments. We propose and demonstrate an effective bright-light attack on this realistic configuration, by applying transient blinding illumination lasting for a fraction of a microsecond and producing several deterministic fake clicks during this time. We show that this attack does not lead to elevated timing jitter in the spoofed output pulse, and is hence not introducing significant errors. Five different SNSPD chip designs were tested. We consider possible countermeasures to this attack.

  13. Ghosting phenomena in single photon counting imagers with Vernier anode.

    Science.gov (United States)

    Yang, Hao; Zhao, Baosheng; Qiurong, Yan; Liu, Yong'an; Hu, Huijun

    2011-02-01

    We provide the ghosting theory of two-dimensional Vernier anode based imagers. The single photon counting detection system based on Vernier anode is constructed. The ghosting, which occurs during the decoding of two-dimensional Vernier anode, and its possible solutions are described in detail. On the basis of the discussion of the decoding algorithm, the ghosting theoretical model is established. Phase conditions on which imaging ghosting can be avoided and the probability distribution function are proposed; the root causes of ghosting of two-dimensional Vernier anode are also discussed.

  14. Multi-group dynamic quantum secret sharing with single photons

    Science.gov (United States)

    Liu, Hongwei; Ma, Haiqiang; Wei, Kejin; Yang, Xiuqing; Qu, Wenxiu; Dou, Tianqi; Chen, Yitian; Li, Ruixue; Zhu, Wu

    2016-07-01

    In this letter, we propose a novel scheme for the realization of single-photon dynamic quantum secret sharing between a boss and three dynamic agent groups. In our system, the boss can not only choose one of these three groups to share the secret with, but also can share two sets of independent keys with two groups without redistribution. Furthermore, the security of communication is enhanced by using a control mode. Compared with previous schemes, our scheme is more flexible and will contribute to a practical application.

  15. Single Photon Detector at Telecom Wavelengths for Quantum Key Distribution

    Institute of Scientific and Technical Information of China (English)

    LIU Yun; WU Qing-Lin; HAN Zheng-Fu; DAI Yi-Min; QUO Guang-Can

    2006-01-01

    Using InGaAs/InP avalanche photodiodes as sensors and coaxial cables as reflection lines to reject spike signals, we have firstly employed the "timing filtering" gates to pick out avalanche signals and have realized the single photon detection at 1550 nm in the temperature range of thermoelectric cooling. A ratio of the dark count rate to the detection efficiency was obtained to be 9×10-5 at 223K. When the detector is applied to a practical quantum key distribution system, the transmission distance can reach 89.5km and the repetition rate can reach 0.33MHz.

  16. Room temperature mid-IR single photon spectral imaging

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2012-01-01

    modern Quantum cascade lasers have evolved as ideal coherent mid-IR excitation sources, simple, low noise, room temperature detectors and imaging systems still lag behind. We address this need presenting a novel, field-deployable, upconversion system for sensitive, 2-D, mid-IR spectral imaging. Measured...... room temperature dark noise is 0.2 photons/spatial element/second, which is a billion times below the dark noise level of cryogenically cooled InSb cameras. Single photon imaging and up to 200 x 100 spatial elements resolution is obtained reaching record high continuous wave quantum efficiency of about...

  17. Spectral density matrix of a single photon measured.

    Science.gov (United States)

    Wasilewski, Wojciech; Kolenderski, Piotr; Frankowski, Robert

    2007-09-21

    We propose and demonstrate a method for measuring the spectral density matrix of a single photon pulse. The method is based on registering Hong-Ou-Mandel interference between a photon to be measured and a pair of attenuated and suitably delayed laser pulses described by a known spectral amplitude. The density matrix is retrieved from a two-dimensional interferogram of coincidence counts. The method has been implemented for a type-I down-conversion source, pumped by ultrashort laser pulses. The experimental results agree well with a theoretical model which takes into account the temporal as well as spatial effects in the source.

  18. Spectral density matrix of a single photon measured

    CERN Document Server

    Wasilewski, W; Frankowski, R; Wasilewski, Wojciech; Kolenderski, Piotr; Frankowski, Robert

    2007-01-01

    We propose and demonstrate a method for measuring the spectral density matrix of a single photon pulse. The method is based on registering Hong-Ou-Mandel interference between photon to be measured and a pair of attenuated and suitably delayed laser pulses described by a known spectral amplitude. The density matrix is retrieved from a two-dimensional interferogram of coincidence counts. The method has been implemented for a type-I downconversion source, pumped by ultrashort laser pulses. The experimental results agree well with a theoretical model which takes into account the temporal as well as spatial effects in the source.

  19. Weak Value Amplification of a Post-Selected Single Photon

    Science.gov (United States)

    Hallaji, Matin

    Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon --- sent through a polarization interferometer and post-selected by photodetection in the almost-dark port --- can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.

  20. Mitigating radiation damage of single photon detectors for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Anisimova, Elena; Higgins, Brendon L.; Bourgoin, Jean-Philippe [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Cranmer, Miles [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Choi, Eric [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); Magellan Aerospace, Ottawa, ON (Canada); Hudson, Danya; Piche, Louis P.; Scott, Alan [Honeywell Aerospace (formerly COM DEV Ltd.), Ottawa, ON (Canada); Makarov, Vadim [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); University of Waterloo, Department of Electrical and Computer Engineering, Waterloo, ON (Canada); Jennewein, Thomas [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Canadian Institute for Advanced Research, Quantum Information Science Program, Toronto, ON (Canada)

    2017-12-15

    Single-photon detectors in space must retain useful performance characteristics despite being bombarded with sub-atomic particles. Mitigating the effects of this space radiation is vital to enabling new space applications which require high-fidelity single-photon detection. To this end, we conducted proton radiation tests of various models of avalanche photodiodes (APDs) and one model of photomultiplier tube potentially suitable for satellite-based quantum communications. The samples were irradiated with 106 MeV protons at doses approximately equivalent to lifetimes of 0.6, 6, 12 and 24 months in a low-Earth polar orbit. Although most detection properties were preserved, including efficiency, timing jitter and afterpulsing probability, all APD samples demonstrated significant increases in dark count rate (DCR) due to radiation-induced damage, many orders of magnitude higher than the 200 counts per second (cps) required for ground-to-satellite quantum communications. We then successfully demonstrated the mitigation of this DCR degradation through the use of deep cooling, to as low as -86 C. This achieved DCR below the required 200 cps over the 24 months orbit duration. DCR was further reduced by thermal annealing at temperatures of +50 to +100 C. (orig.)

  1. Research on high-speed single photon detector

    Science.gov (United States)

    Wang, Chao; Yang, Hao; Wang, Di; Ma, Haiqiang; Luo, Kaihong; Sun, Zhibin; Zhai, Guangjie

    2010-10-01

    Single-photon detector based on an InGaAs avalanche photodiode is one of hot research on the quantum photon, and is one of the key technologies on quantum communication and quantum image. It is widely used in applications as high sensitive photon spectrum, high speed optic measurement and so on. A suitable delay and comparator with latch function circuit are used to prevent positive and negative transient pulses from influencing the detection of true photon induced avalanches. A dead time modulation feedback control circuit decreases the after-pulse. Especially, ECL difference circuit is the key of high speed single photon detector. In addition, the detector uses the hot tube fan-cooling method. From the performance test, the lowest temperature reaches -62°C, the minimum gate pulse width is 2ns (Full-Width-Half-Max, FWHM) and the dark counter rate is 2.5×10-6 ns-1 with a detection rate of 10MHz when the quantum efficiency is more than 10%.

  2. Experimental observation of anomalous trajectories of single photons

    Science.gov (United States)

    Zhou, Zong-Quan; Liu, Xiao; Kedem, Yaron; Cui, Jin-Min; Li, Zong-Feng; Hua, Yi-Lin; Li, Chuan-Feng; Guo, Guang-Can

    2017-04-01

    A century after its conception, quantum mechanics still hold surprises that contradict many "common sense" notions. The contradiction is especially sharp in case one consider trajectories of truly quantum objects such as single photons. From a classical point of view, trajectories are well defined for particles, but not for waves. The wave-particle duality forces a breakdown of this dichotomy and quantum mechanics resolves this in a remarkable way: Trajectories can be well defined, but they are utterly different from classical trajectories. Here, we give an operational definition to the trajectory of a single photon by introducing a technique to mark its path using its spectral composition. The method demonstrates that the frequency degree of freedom can be used as a bona fide quantum measurement device (meter). The analysis of a number of setups, using our operational definition, leads to anomalous trajectories which are noncontinuous and in some cases do not even connect the source of the photon to where it is detected. We carried out an experimental demonstration of these anomalous trajectories using a nested interferometer. We show that the two-state vector formalism provides a simple explanation for the results.

  3. Avalanche photodiodes and quenching circuits for single-photon detection

    Science.gov (United States)

    Cova, S.; Ghioni, M.; Lacaita, A.; Samori, C.; Zappa, F.

    1996-04-01

    Avalanche photodiodes, which operate above the breakdown voltage in Geiger mode connected with avalanche-quenching circuits, can be used to detect single photons and are therefore called single-photon avalanche diodes SPAD's. Circuit configurations suitable for this operation mode are critically analyzed and their relative merits in photon counting and timing applications are assessed. Simple passive-quenching circuits (PQC's), which are useful for SPAD device testing and selection, have fairly limited application. Suitably designed active-quenching circuits (AQC's) make it possible to exploit the best performance of SPAD's. Thick silicon SPAD's that operate at high voltages (250-450 V) have photon detection efficiency higher than 50% from 540-to 850-nm wavelength and still approximately 3% at 1064 nm. Thin silicon SPAD's that operate at low voltages (10-50 V) have 45% efficiency at 500 nm, declining to 10% at 830 nm and to as little as 0.1% at 1064 nm. The time resolution achieved in photon timing is 20 ps FWHM with thin SPAD's; it ranges from 350 to 150 ps FWHM with thick SPAD's. The achieved minimum counting dead time and maximum counting rate are 40 ns and 10 Mcps with thick silicon SPAD's, 10 ns and 40 Mcps with thin SPAD's. Germanium and III-V compound semiconductor SPAD's extend the range of photon-counting techniques in the near-infrared region to at least 1600-nm wavelength.

  4. Deterministic reshaping of single-photon spectra using cross-phase modulation.

    Science.gov (United States)

    Matsuda, Nobuyuki

    2016-03-01

    The frequency conversion of light has proved to be a crucial technology for communication, spectroscopy, imaging, and signal processing. In the quantum regime, it also offers great potential for realizing quantum networks incorporating disparate physical systems and quantum-enhanced information processing over a large computational space. The frequency conversion of quantum light, such as single photons, has been extensively investigated for the last two decades using all-optical frequency mixing, with the ultimate goal of realizing lossless and noiseless conversion. I demonstrate another route to this target using frequency conversion induced by cross-phase modulation in a dispersion-managed photonic crystal fiber. Owing to the deterministic and all-optical nature of the process, the lossless and low-noise spectral reshaping of a single-photon wave packet in the telecommunication band has been readily achieved with a modulation bandwidth as large as 0.4 THz. I further demonstrate that the scheme is applicable to manipulations of a nonclassical frequency correlation, wave packet interference, and entanglement between two photons. This approach presents a new coherent frequency interface for photons for quantum information processing.

  5. Direct generation of linearly polarized single photons with a deterministic axis in quantum dots

    Science.gov (United States)

    Wang, Tong; Puchtler, Tim J.; Patra, Saroj K.; Zhu, Tongtong; Ali, Muhammad; Badcock, Tom J.; Ding, Tao; Oliver, Rachel A.; Schulz, Stefan; Taylor, Robert A.

    2017-08-01

    We report the direct generation of linearly polarized single photons with a deterministic polarization axis in self-assembled quantum dots (QDs), achieved by the use of non-polar InGaN without complex device geometry engineering. Here, we present a comprehensive investigation of the polarization properties of these QDs and their origin with statistically significant experimental data and rigorous k·p modeling. The experimental study of 180 individual QDs allows us to compute an average polarization degree of 0.90, with a standard deviation of only 0.08. When coupled with theoretical insights, we show that these QDs are highly insensitive to size differences, shape anisotropies, and material content variations. Furthermore, 91% of the studied QDs exhibit a polarization axis along the crystal [1-100] axis, with the other 9% polarized orthogonal to this direction. These features give non-polar InGaN QDs unique advantages in polarization control over other materials, such as conventional polar nitride, InAs, or CdSe QDs. Hence, the ability to generate single photons with polarization control makes non-polar InGaN QDs highly attractive for quantum cryptography protocols.

  6. cGMP in Mouse Rods: the spatiotemporal dynamics underlying single photon responses

    Directory of Open Access Journals (Sweden)

    Owen P. Gross

    2015-03-01

    Full Text Available Vertebrate vision begins when retinal photoreceptors transduce photons into membrane hyperpolarization, which reduces glutamate release onto second-order neurons. In rod photoreceptors, transduction of single photons is achieved by a well-understood G-protein cascade that modulates cGMP levels, and in turn, cGMP-sensitive inward current. The spatial extent and depth of the decline in cGMP during the single photon response have been major issues in phototransduction research since the discovery that single photons elicit substantial and reproducible changes in membrane current. The spatial profile of cGMP decline during the single photon response affects signal gain, and thus may contribute to reduction of trial-to-trial fluctuations in the single photon response. Here we summarize the general principles of rod phototransduction, emphasizing recent advances in resolving the spatiotemporal dynamics of cGMP during the single photon response.

  7. Single-Photon Technologies Based on Quantum-Dots in Photonic Crystals

    DEFF Research Database (Denmark)

    Lehmann, Tau Bernstorff

    In this thesis, the application of semiconductor quantum-dots in photonic crystals is explored as aresource for single-photon technology.Two platforms based on photonic crystals, a cavity and a waveguide, are examined as platformssingle-photon sources. Both platforms demonstrate strong single-photon...... purity under quasi-resonantexcitation. Furthermore the waveguide based platform demonstrates indistinguishable single-photonsat timescales up to 13 ns.A setup for active demultiplexing of single-photons to a three-fold single-photon state is proposed.Using a fast electro-optical modulator, single-photons...... from a quantum-dot are routed on timescalesof the exciton lifetime. Using active demultiplexing a three-fold single-photon state is generated at anextracted rate of 2:03 ±0:49 Hz.An on-chip power divider integrated with a quantum-dot is investigated. Correlation measurementof the photon statistic...

  8. Measurement of Ultra-Short Single-Photon Pulse Duration with Two-Photon Interference

    Institute of Scientific and Technical Information of China (English)

    LV Fan; SUN Fang-Wen; ZOU Chang-Ling; HAN Zheng-Fu; GUO Guang-Can

    2011-01-01

    We proposed a protocol of measuring the duration of ultra-short single-photon pulse with two-photon interference.The pulse duration can be obtained from the width of the visibility of two-photon Hong-Ou-Mandel interference or the indistinguishability of the two photons. Moreover, the shape of a single-photon pulse can be measured with ultra-short single-photon pulses through the two-photon interference.%@@ We proposed a protocol of measuring the duration of ultra-short single-photon pulse with two-photon interference.The pulse duration can be obtained from the width of the visibility of two-photon Hong-Ou-Mandel interference or the indistinguishability of the two photons.Moreover, the shape of a single-photon pulse can be measured with ultra-short single-photon pulses through the two-photon interference.

  9. Performance limits of a single photon counting pixel system

    Energy Technology Data Exchange (ETDEWEB)

    Chmeissani, M.; Mikulec, B. E-mail: bettina.mikulec@cern.ch

    2001-03-11

    X-ray imaging using hybrid pixel detectors in single photon counting mode is a relatively recent and exciting development. The photon counting mode implies that each pixel has a threshold in energy above which a hit is recorded. Sharing of charge between adjacent pixels would therefore lead to a loss of registered hits and for medical imaging applications to a higher patient dose. This explains why the demand for high spatial resolution and consequently small pixel sizes (<100 {mu}m) motivates the Medipix2 collaboration to study the effects of charge sharing between pixels on system performance. Two different simulation codes are used to simulate the energy loss inside the detector and the charge transport towards the pixel electrodes. The largest contribution to the lateral spreading of charge comes from diffusion and can result in a considerable loss of detection efficiency in photon counting systems for small pixel sizes.

  10. Adaptive Depth Imaging with Single-Photon Detectors

    CERN Document Server

    He, Weiji; Lin, Jie; Shen, Shanshan; Chen, Qian; Gu, Guohua; Zhou, Beibei; Zhang, Ping

    2016-01-01

    For active optical imaging, the use of single-photon detectors could greatly improve the detection sensitivity of the system. However in low light-level, traditional maximum-likelihood based imaging method needs long acquisition time to capture clear three-dimensional (3D) image. To tackle this problem, we present a novel imaging method for depth estimate, which can obtain the accurate depth image in a short acquisition time. We exploit the temporal correlations of signal and avoid building the photon-count histogram of the maximum likelihood depth estimate. Our method can efficiently distinguish signal from noise and adaptively change the dwell time of each pixel. The experiment results demonstrate that we can fast obtain the accurate depth image despite the existence of strong background noise.

  11. Modal coupling of single photons to a nanofibre

    CERN Document Server

    Gaio, Michele; Castro-Lopez, Marta; Pisignano, Dario; Camposeo, Andrea; Sapienza, Riccardo

    2015-01-01

    Nanoscale quantum optics of individual light emitters placed in confined geometries is developing as an exciting new research field aiming at efficient manipulation of single-photons . This requires selective channelling of light into specific optical modes of nanophotonic structures. Hybrid photonic systems combining emitters with nanostructured media can yield this functionality albeit limited by the required nanometre-scale spatial and spectral coupling. Furthermore, assessing the coupling strength presents significant challenges and disentangling the different modal contribution is often impossible. Here, we show that momentum spectroscopy of individually addressed emitters, embedded in a nanofibre, can be used to quantify the modal coupling efficiency to the nanofibre modes. For free-standing polymer nanofibres doped with colloidal quantum dots, we report broadband coupling to the fundamental mode of up $\\beta_{01}=31\\pm2\\%$, in robust agreement with theoretical calculations. Electrospun soft-matter nano...

  12. Single Photon studies in ATLAS with Run 2 dataset

    CERN Document Server

    Aparisi Pozo, Javier Alberto; Solans Sanchez, Carlos; CERN. Geneva. EP Department

    2016-01-01

    We present a performance study of photon reconstruction within the Higgs working group of the ATLAS experiment. The analysis use a data sample of proton-proton collisions at center-of-mass energy of $\\sqrt{s} = 13~TeV$, recorded with the ATLAS detector at the LHC in 2015+2016, corresponding to a total integrated luminosity of 14.5 $fb^{-1}$ (at the moment). The performance of electron and photon reconstruction plays a critical role in the reach of many analysis, including $H\\rightarrow \\gamma \\gamma$ and $H\\rightarrow 4l$ concerning Higgs searches. This work is a study of single photon conversions with the ATLAS detector.

  13. Electromagnetic fields, size, and copy of a single photon

    CERN Document Server

    Liu, Shan-Liang

    2016-01-01

    We propose the expressions of electromagnetic fields of a single photon which properly describe the known characteristics of a photon, derive the relations between the photon size and wavelength on basis of the expressions, reveal the differences between a photon and its copy, and give the specific expressions of annihilation and creation operators of a photon. The results show that a photon has length of half the wavelength, and its radius is proportional to square root of the wavelength; a photon and its copy have the phase difference of {\\pi} and constitute a phase-entangled state; the N-photon phase-entangled state, which is formed by the sequential stimulated emission and corresponds to the wave train in optics, is not a coherent state, but it is the eigenstate of the number operator of photons.

  14. Advanced time-correlated single photon counting techniques

    CERN Document Server

    Becker, Wolfgang

    2005-01-01

    Time-correlated single photon counting (TCSPC) is a remarkable technique for recording low-level light signals with extremely high precision and picosecond-time resolution. TCSPC has developed from an intrinsically time-consuming and one-dimensional technique into a fast, multi-dimensional technique to record light signals. So this reference and text describes how advanced TCSPC techniques work and demonstrates their application to time-resolved laser scanning microscopy, single molecule spectroscopy, photon correlation experiments, and diffuse optical tomography of biological tissue. It gives practical hints about constructing suitable optical systems, choosing and using detectors, detector safety, preamplifiers, and using the control features and optimising the operating conditions of TCSPC devices. Advanced TCSPC Techniques is an indispensable tool for everyone in research and development who is confronted with the task of recording low-intensity light signals in the picosecond and nanosecond range.

  15. Photon statistics measurement by use of single photon detection

    Institute of Scientific and Technical Information of China (English)

    XIAO Liantuan; JIANG Yuqiang; ZHAO Yanting; YIN Wangbao; ZHAO Jianming; JIA Suotang

    2004-01-01

    The direct measurement of the Mandel para- meter of weak laser pulses, with 10 ns pulse duration time and the mean number of photon per pulsebeing approximately 0.1, is investigated by recording every photocount event. With the Hanbury Brown and Twiss detection scheme, and not more than one photon per pulse being detected during the sample time by single-photon counters, we have found that the single mode diode laser with driving current lower than the threshold yields a sub-Poissonian statistics. In addition, when the diode laser driving current is much higher than the threshold, it is validated that the Mandel parameter QC of the Poissonian coherent state is nearly The experimental results are in good agreement with theoretical prediction considering the measurement error.

  16. Detection of single photons with THickGEM-based counters

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, M. [INFN, Sezione di Torino and University of East Piemonte, Alessandria (Italy); Barbosa, F. [I3N - Physics Department, University of Aveiro (Portugal); Birsa, R. [INFN, Sezione di Trieste, Trieste (Italy); Bradamante, F.; Bressan, A. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Chiosso, M. [INFN, Sezione di Torino and University of Torino, Torino (Italy); Ciliberti, P. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Dalla Torre, S. [INFN, Sezione di Trieste, Trieste (Italy); Denisov, O. [INFN, Sezione di Torino, Torino (Italy); Duic, V. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Ferrero, A. [INFN, Sezione di Torino and University of Torino, Torino (Italy); Finger, M.; Finger, M. [Charles University, Praga (Czech Republic); JINR, Dubna (Russian Federation); Fischer, H. [Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Giorgi, M. [INFN, Sezione di Trieste and University of Trieste, Trieste (Italy); Gobbo, B.; Gregori, M. [INFN, Sezione di Trieste, Trieste (Italy); Heinsius, F.H.; Herrmann, F.; Koenigsmann, K. [Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); and others

    2012-12-11

    Cherenkov imaging counters requiring large photosensitive areas, the capability to stand high rates and to operate in magnetic field environments could benefit from the use of photon detectors based on THick Gaseous Electron Multiplier (THGEM) coupled to a solid state CsI photo-cathode. A systematic study of the THGEM detector response as a function of its geometrical parameters and electrodes' applied voltage has been performed. Dedicated electrostatic calculations to optimize the detector design have been accomplished. Data obtained from small photon detector prototypes operating in single photon detection mode are presented and discussed. In particular the key aspect of photo-electron extraction from the photo-cathode surface is investigated via the timing spectrum response of the detector for different electric field conditions at the photo-cathode: a comparison of the measured time distributions and the simulation results is illustrated.

  17. Single photon light detector for deep ocean applications

    Energy Technology Data Exchange (ETDEWEB)

    Matsuno, S.; Babson, J.; Learned, J.G.; O' Connor, D.; Grieder, P.K.F.; Kitamura, T.; Mitsui, K.; Ohashi, Y.; Okada, A.; Clem, J.

    1989-03-15

    We have developed a single photon sensitive light detector module which can be operated in the ocean to a depth of 5000 m. It was designed primarily to be used as a Cherenkov light detector in conjunction with the DUMAND (Deep Underwater Muon And Neutrino Detector) experiment. After calibration in the laboratory, seven detectors, assembled in a vertical string geometry, have been operated simultaneously in the deep ocean off the coast of the island of Hawaii. Cosmic ray muons have been recorded successfully at dephts ranging from 2000 to 4000 m. The results have demonstrated the capability of the detector; it fulfills the specifications required for the modules to be used in a deep ocean muon and neutrino detector.

  18. Single photon light detector for deep ocean applications

    Science.gov (United States)

    Matsuno, S.; Babson, J.; Learned, J. G.; O'Connor, D.; Grieder, P. K. F.; Kitamura, T.; Mitsui, K.; Ohashi, Y.; Okada, A.; Clem, J.; Webster, M.; Wilson, C.

    1989-03-01

    We have developed a single photon sensitive light detector module which can be operated in the ocean to a depth of 5000 m. It was designed primarily to be used as a Cherenkov light detector in conjunction with the DUMAND (Deep Underwater Muon And Neutrino Detector) experiment. After calibration in the laboratory, seven detectors, assembled in a vertical string geometry, have been operated simultaneously in the deep ocean off the coast of the island of Hawaii. Cosmic ray muons have been recorded successfully at depths ranging from 2000 to 4000 m. The results have demonstrated the capability of the detector; it fulfills the specifications required for the modules to be used in a deep ocean muon and neutrino detector.

  19. Interfacing single photons and single quantum dots with photonic nanostructures

    CERN Document Server

    Lodahl, Peter; Stobbe, Søren

    2013-01-01

    Photonic nanostructures provide a way of tailoring the interaction between light and matter and the past decade has witnessed a tremendous experimental and theoretical progress on this subject. In particular, the combination with semiconductor quantum dots has proven very successful. This manuscript reviews quantum optics with excitons in single quantum dots embedded in photonic nanostructures. The ability to engineer the interaction strength in integrated photonic nanostructures enables a range of fundamental quantum-electrodynamics experiments on, e.g., spontaneous-emission control, modified Lamb shifts, and enhanced dipole-dipole interaction. Furthermore, highly efficient single-photon sources and giant photon nonlinearities may be constructed with immediate applications for photonic quantum-information processing. The review summarizes the general theoretical framework of photon emission including the role of dephasing processes, and applies it to photonic nanostructures of current interest, such as photo...

  20. Single-photon avalanche photodiodes with integrated quenching resistor

    Energy Technology Data Exchange (ETDEWEB)

    Mazzillo, M. [STMicroelectronics, IMS R and D Stradale Primosole 50, 95121 Catania (Italy)], E-mail: massimo.mazzillo@st.com; Condorelli, G.; Piazza, A.; Sanfilippo, D.; Valvo, G.; Carbone, B.; Fallica, G. [STMicroelectronics, IMS R and D Stradale Primosole 50, 95121 Catania (Italy); Billotta, S.; Belluso, M.; Bonanno, G. [INAF-Osservatorio Astrofisico di Catania, Via Santa Sofia 78, 95123 Catania (Italy); Pappalardo, A.; Cosentino, L.; Finocchiaro, P. [INFN-Laboratori Nazionali del Sud, Via Santa Sofia 64, 95125 Catania (Italy)

    2008-06-21

    In this paper we present the results of the first electrical and optical characterization performed on STMicroelectronics new photosensor technology based on silicon single-photon avalanche photodiodes (SPAD). On the prospective of the design and the manufacturing of large-area silicon photomultipliers to be used as photodetectors for nuclear medicine imaging applications, we have modified our previous SPAD technology by means of the integration of a high-value quenching resistor to the photodiode. Moreover, an appropriate antireflective coating layer and the reduction of the quasi-neutral region thickness above the thin junction depletion layer have been introduced in the process flow of the device to enhance its spectral response in blue and near ultraviolet wavelength ranges. High gain, low leakage currents, low dark noise, very good quantum detection efficiency in blue-near UV ranges and a good linearity of the photodiode response to the incident luminous flux are the main characterization results.

  1. Single-Photon Superradiance from a Quantum Dot

    Science.gov (United States)

    Tighineanu, Petru; Daveau, Raphaël S.; Lehmann, Tau B.; Beere, Harvey E.; Ritchie, David A.; Lodahl, Peter; Stobbe, Søren

    2016-04-01

    We report on the observation of single-photon superradiance from an exciton in a semiconductor quantum dot. The confinement by the quantum dot is strong enough for it to mimic a two-level atom, yet sufficiently weak to ensure superradiance. The electrostatic interaction between the electron and the hole comprising the exciton gives rise to an anharmonic spectrum, which we exploit to prepare the superradiant quantum state deterministically with a laser pulse. We observe a fivefold enhancement of the oscillator strength compared to conventional quantum dots. The enhancement is limited by the base temperature of our cryostat and may lead to oscillator strengths above 1000 from a single quantum emitter at optical frequencies.

  2. Producing high fidelity single photons with optimal brightness

    CERN Document Server

    Laiho, K; Silberhorn, Ch

    2009-01-01

    Parametric down-conversion (PDC) offers the possibility to control the fabrication of non-Gaussian states such as Fock states. However, in conventional PDC sources energy and momentum conservation introduce strict frequency and photon number correlations, which impact the fidelity of the prepared state. In our work we optimize the preparation of single-photon Fock state from the emission of waveguided PDC via spectral filtering. We study the effect of correlations via photon number resolving detection and quantum interference. Our measurements show how the reduction of mixness due to filtering can be evaluated. Interfering the prepared photon with a coherent state we establish an experimentally measured fidelity of the produced target state of 78%.

  3. Fragmentation dynamics of ammonia cluster ions after single photon ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, E.; Vries, J. de; Steger, H.; Menzel, C.; Kamke, W.; Hertel, I.V. (Freiburg Univ. (Germany, F.R.). Fakultaet fuer Physik Freiburg Univ. (Germany, F.R.). Freiburger Materialforschungszentrum)

    1991-01-01

    A reflecting time of flight mass spectrometer (RETOF) is used to study unimolecular and collision induced fragmentation of ammonia cluster ions. Synchrotron radiation from the BESSY electron storage ring is used in a range of photon energies from 9.08 up to 17.7 eV for single photon ionisation of neutral clusters in a supersonic beam. The threshold photoelectron photoion coincidence technique (TPEPICO) is used to define the energy initially deposited into the cluster ions. Metastable unimolecular decay ({mu}s range) is studied using the RETOF's capacity for energy analysis. Under collision free conditions the by far most prominent metastable process is the evaporation of one neutral NH{sub 3} monomer from protonated clusters (NH{sub 3}){sub x}NH{sub 4}{sup +}. Abundance of homogeneous vs. protonated cluster ions and of metastable fragments are reported as a function of photon energy and cluster size up to n=10. (orig.).

  4. Trapping of Single Atoms with Single Photons in Cavity QED

    CERN Document Server

    Doherty, A C; Hood, C J; Kimble, H J

    2000-01-01

    Two recent experiments have reported the trapping of individual atoms inside optical resonators by the mechanical forces associated with single photons [Hood et al., Science 287, 1447 (2000) and Pinkse et al., Nature 404, 365 (2000)]. Here we analyze the trapping dynamics in these settings, focusing on two points of interest. Firstly, we investigate the extent to which light-induced forces in these experiments are distinct from their free-space counterparts. Secondly, we explore the quantitative features of the resulting atomic motion and how these dynamics are mapped onto variations of the intracavity field. Not surprisingly, qualitatively distinct atomic dynamics arise as the coupling and dissipative rates are varied. For the experiment of Hood et al., we show that atomic motion is largely conservative and is predominantly in radial orbits transverse to the cavity axis. A comparison with the free-space theory demonstrates that the fluctuations of the dipole force are suppressed by an order of magnitude. Thi...

  5. Optical precursors from classical waves to single photons

    CERN Document Server

    Chen, JF; Loy, MMT; Du, Shengwang

    2013-01-01

    Ever since Einstein’s special relativity in 1905, the principle of invariant light speed in vacuum has been attracting attention from a wide range of disciplines. How to interpret the principle of light speed? Is light referred to continuous light, or light pulse with definite boundaries? Recent discovery of superluminal medium triggered vigorous discussion within the Physics community. Can communication via such “superluminal channel” break the speed limit and thus violate causality principle? Or, will a single photon, which is not governed by classical laws of Physics, tend to break the speed limit? To solve these problems, in this Brief we bring in optical precursor, the theoretical works for which started as early as 1914. This is a typical optical phenomenon combining wave propagation theory and light-wave interaction. Both theory and experimental works are covered in this Brief. The study of precursor verifies that the effective information carried by light pulses can never exceed the speed of lig...

  6. Single-photon source engineering using a Modal Method

    DEFF Research Database (Denmark)

    Gregersen, Niels

    Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined...... as the number of detected photons by the collection optics per trigger, is desired, and to obtain this high efficiency the photonic environment must be engineered [1] such that all the emitted light couples to the collection optics. A recent design approach is based on a quantum dot placed inside a photonic...... nanowire (Fig. 1). This structure does not feature a cavity but instead relies on a geometrical screening effect to efficiently couple photons to the fundamental waveguide mode. Furthermore, the photonic nanowire SPS implements a bottom metal mirror and exploits tapering strategies based on conical tapers...

  7. Single photon time transfer link model for GNSS satellites

    Science.gov (United States)

    Vacek, Michael; Michalek, Vojtech; Peca, Marek; Prochazka, Ivan; Blazej, Josef

    2015-05-01

    The importance of optical time transfer serving as a complement to traditional microwave links, has been attested for GNSSes and for scientific missions. Single photon time transfer (SPTT) is a process, allowing to compare (subtract) time readings of two distant clocks. Such a comparison may be then used to synchronize less accurate clock to a better reference, to perform clock characterization and calibration, to calculate mean time out of ensemble of several clocks, displaced in space. The single-photon time transfer is well established in field of space geodesy, being supported by passive retro-reflectors within space segment of five known GNSSes. A truly two-way, active terminals work aboard of Jason-2 (T2L2) - multiphoton operation, GNSS Beidou (Compass) - SPTT, and are going to be launched within recent ACES project (ELT) - SPTT, and GNSS GLONASS - multiphoton operation. However, there is still missing comprehensive theoretical model of two-way (using satellite receiver and retroreflector) SPTT link incorporating all crucial parameters of receiver (both ground and space segment receivers), transmitter, atmosphere effects on uplink and downlink path, influence of retroreflector. The input to calculation of SPTT link performance will be among others: link budget (distance, power, apertures, beam divergence, attenuation, scattering), propagating medium (atmosphere scintillation, beam wander, etc.), mutual Tx/Rx velocity, wavelength. The SPTT model will be evaluated without the properties of real components. These will be added in the further development. The ground-to-space SPTT link performance of typical scenarios are modeled. This work is a part of the ESA study "Comparison of optical time-transfer links."

  8. Single-photon multi-ports router based on the coupled cavity optomechanical system.

    Science.gov (United States)

    Li, Xun; Zhang, Wen-Zhao; Xiong, Biao; Zhou, Ling

    2016-12-22

    A scheme of single-photon multi-port router is put forward by coupling two optomechanical cavities with waveguides. It is shown that the coupled two optomechanical cavities can exhibit photon blockade effect, which is generated from interference of three mode interaction. A single-photon travel along the system is calculated. The results show that the single photon can be controlled in the multi-port system because of the radiation pressure, which should be useful for constructing quantum network.

  9. Time-division phase modulated single-photon interference in a Sagnac interferometer

    Institute of Scientific and Technical Information of China (English)

    WU Guang; ZHOU Chunyuan; ZENG Heping

    2003-01-01

    We introduce a stable, long-distance single- photon Sagnac interferometer, which has a balanced configuration to efficiently compensate phase drift caused by change of the fiber-optic path. By using time-division phase modulation, single-photon interference was realized at 1550 nm in a 5-km-long as well as 27-km-long Sagnac fiber loops, with a fringe visibility higher than 90% and long-term stability. The stable performance of the single-photon interference indicated that the time-division phase-modulated Sag- nac interferometer might readily lead to practical applications in single-photon routing and quantum cryptography.

  10. Recent Advances for High-Efficiency Sources of Single Photons Based on Photonic Nanowires

    DEFF Research Database (Denmark)

    Gerard, J. M.; Claudon, J.; Munsch, M.

    2012-01-01

    Photonic nanowires have recently been used to tailor the spontaneous emission of embedded quantum dots, and to develop record efficiency single-photon sources. We will present recent developments in this field mainly 1) the observation of a strong inhibition of the spontaneous emission of quantum...... dots in ultrathin photonic wires 2) the control of the linear polarization of the single photons by photonic wires with an elliptical section, 3) the joint observation (unlike-cavity-based devices) of a record high efficiency and pure single photon emission process in a photonic wire single photon...

  11. Single photon emission CT perfusion imaging of cerebral blood flow of early syphilis patients

    Institute of Scientific and Technical Information of China (English)

    施辛; 吴锦昌; 刘增礼; 唐军; 苏玉华

    2003-01-01

    Objective To injvestigate the cerebral blood flow of patients with early syphilis. Methods 99Tcm-ECD as brain perfusion imaging agent was used in single photon emission computed tomography (SPECT) for 32 patients with early syphilis and 15 controls. Visual analyses were made on every BSPECT image. Results The 32 patients with early syphilis had general, patchy hypoperfusion of cerebral blood flow. Fourteen of the 32 patients had 48 episodes of marked patchy hypoperfusion of rCBF. The responsible areas of hypoperfusion in a patchy distribution involved the left frontal lobe (6 episodes), right frontal lobe (3), left parietal lobe (7), right parietal lobe (6), left temporal lobe (11), right temporal lobe (5), left occipital lobe (3), left basal ganglia (3), cerebellum (1), and nerve nuceus (1). No abnormality was found in the control group.Conclusions Cerebral blood flow abnormalities exist in patients with early syphilis. General patchy hypoperfusion on SPECT imaging is common.

  12. Parametric System Identification of Thermoelectric Cooler for Single Photon Avalanche Diode Application

    Directory of Open Access Journals (Sweden)

    Nurul Izzati Samsuddin

    2013-06-01

    Full Text Available The purpose of this study is to model the Thermoelectric Coolers (TEC by means of computational intelligence system identification. Thermoelectric coolers are widely used in cooling, maintaining and stabilizing the temperature of the Single Photon Avalanche Diode (SPAD. SPAD is a temperature sensitive optoelectronic device, where even a slight variation in temperature can cause unstable performance in quantum efficiency, responsibility and dark counts. However, it is not a simple task to derive a mathematical model for TEC since it varies with the operating condition. In this study, Particle Swarm Optimization (PSO was used to identify the mathematical model of the multistage TEC (1639733 from Element 14, which encapsulates dynamics of the SPAD, heat sink and components of the cooling heat exchanger. The model was validated by correlation tests, percentage accuracy and also by comparing its time and frequency responses against that of the TEC. It was found that the obtained model has a good representation of the actual system.

  13. Guided wave technology for a telecom wavelength heralded single photon source

    CERN Document Server

    Alibart, O; Ostrowsky, D B; Baldi, P; Alibart, Olivier; Tanzilli, Sebastien; Ostrowsky, Daniel Barry; Baldi, Pascal

    2004-01-01

    We report on a guided wave heralded photon source based on the creation of non-degenerate photon pairs by spontaneous parametric down conversion in a Periodically Poled Lithium Niobate waveguide. Using the signal photon at 1310 nm as a trigger, a gated detection process permits announcing the arrival of single photons at 1550 nm at the output of a single mode optical fiber with the best probability to date of 0.38. The multi-photon emission probability is reduced by a factor of 10 compared to poissonian light sources. Relying on guided wave technologies such as integrated optics and fiber optics components, our source offers stability, compactness and efficiency and can serve as a paradigm for guided wave devices applied to quantum communication and computation using existing telecom networks.

  14. Value of interictal/ictal single photon emission computed tomography regional cerebral blood flow imaging in localization of epileptic foci%发作间期/发作期SPECT rCBF显像在癫痫灶定位诊断中的价值

    Institute of Scientific and Technical Information of China (English)

    杨雅娜; 罗焱; 胡云; 苏红媛; 杨辉; 张青

    2012-01-01

    Objective To study the value of interictal/ictal single photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) imaging in localization of epileptic foci. Methods Interictal/ictal SPECT, EEG, VEEG, CT or MRI, and ECoG of 115 epilepsy patients, who underwent operation in Department of Neurosurgery, Xinqiao Hospital, Third Military Medical University, were retrospectively analyzed and compared. Results The positive detection rate of interictal/ictal SPECT for epilepsy was higher than that of EEG, VEEG, CT and MRI (90.4% va 37.4% , 82.6% , 48. 8% and 54.2% , P <0.05). The localization rate of interictal/ictal SPECT for epileptic foci was higher than that of ECoG (91. 3% vs 71. 2% , P<0.05). Conclusion The interictal/ictal SPECT is highly consistent with ECoG in localization of epileptic foci, thus playing an important role in preoperative localization of epilepsy.%目的 探讨发作间期/发作期SPECT局部脑血流灌注显像(regional cerebral blood flow,rCBF)在癫痫术前定位诊断中的价值.方法 回顾性分析第三军医大学新桥医院神经外科行外科手术治疗的115例癫痫患者,术前分别行发作间期/发作期SPECT显像、常规脑电图(electroencephalogram,EEG)、视频脑电图(vedio-EEC,VEEG)、CT或MRI检查,术中行皮层脑电图(electrocorticogram,ECoG)监测,与发作间期/发作期SPECT、EEG、VEEG、CT和MRI检查结果进行比较分析.结果 发作间期/发作期SPECT检出癫痫的阳性率为90.4%,高于EEG的37.4% (P <0.05)、VEEG的82.6%(P>0.05)、CT的48.8% (P <0.05)和MRI的54.2% (P <0.05).与术中ECoG结果比较,发作间期/发作期SPECT对癫痫灶定侧率为91.3%,定位率为71.2%.结论 术前发作间期/发作期SPECT显像与ECoG在癫痫灶定位诊断上具有较高的一致性,在术前综合定位诊断中具有重要意义.

  15. Computer screens and brain cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wood, A.W. [Swinburne University of Technology, Hawthorn, VIC (Australia). School of Biophysical Sciences and Electrical Engineering

    1995-12-01

    Australia, both in the media and at the federal government level, over possible links between screen-based computer use and cancer, brain tumour in particular. The screen emissions assumed to be the sources of the putative hazard are the magnetic fields responsible for horizontal and vertical scanning of the display. Time-varying fluctuations in these magnetic fields induce electrical current flows in exposed tissues. This paper estimates that the induced current densities in the brain of the computer user are up to 1 mA/m{sup 2} (due to the vertical flyback). Corresponding values for other electrical appliances or installations are in general much less than this. The epidemiological literature shows no obvious signs of a sudden increase in brain tumour incidence, but the widespread use of computers is a relatively recent phenomenon. The occupational use of other equipment based on cathode ray tubes (such as TV repair) has a much longer history and has been statistically linked to brain tumour in some studies. A number of factors make this an unreliable indicator of the risk from computer screens, however. 42 refs., 3 tabs., 2 figs.

  16. Preoperative nodal staging of non-small cell lung cancer using 99mTc-sestamibi spect/ct imaging

    Directory of Open Access Journals (Sweden)

    Juliana Muniz Miziara

    2011-01-01

    Full Text Available OBJECTIVES: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using 99mTc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. METHODS: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with 99mTc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. RESULTS: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for 99mTc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative

  17. Controlled Single-Photon Emission from a Single Trapped Two-Level Atom

    CERN Document Server

    Darquié, B; Dingjan, J; Beugnon, J; Bergamini, S; Sortais, Y; Messin, G; Browaeys, A; Grangier, P; Darqui\\'{e}, Benoit; Jones, Matthew; Dingjan, Jos; Beugnon, Jerome; Bergamini, Silvia; Sortais, Yvan; Messin, Gaetan; Browaeys, Antoine; Grangier, Philippe

    2005-01-01

    By illuminating an individual rubidium atom stored in a tight optical tweezer with short resonant light pulses, we create an efficient triggered source of single photons with a well-defined polarization. The measured intensity correlation of the emitted light pulses exhibits almost perfect antibunching. Such a source of high rate, fully controlled single photon pulses has many potential applications for quantum information processing.

  18. Corpuscular Model of Two-Beam Interference and Double-Slit Experiments with Single Photons

    NARCIS (Netherlands)

    Jin, Fengping; Yuan, Shengjun; De Raedt, Hans; Michielsen, Kristel; Miyashita, Seiji

    2010-01-01

    We introduce an event-based corpuscular simulation model that reproduces the wave mechanical results of single-photon double-slit and two-beam interference experiments and (of a one-to-one copy of an experimental realization) of a single-photon interference experiment with a Fresnel biprism. The sim

  19. Corpuscular Model of Two-Beam Interference and Double-Slit Experiments with Single Photons

    NARCIS (Netherlands)

    Jin, Fengping; Yuan, Shengjun; De Raedt, Hans; Michielsen, Kristel; Miyashita, Seiji

    We introduce an event-based corpuscular simulation model that reproduces the wave mechanical results of single-photon double-slit and two-beam interference experiments and (of a one-to-one copy of an experimental realization) of a single-photon interference experiment with a Fresnel biprism. The

  20. A novel high-efficiency single-mode quantum dot single photon source

    DEFF Research Database (Denmark)

    Gerard, J.M.; Gregersen, Niels; Nielsen, Torben Roland

    2008-01-01

    We present a novel single-mode single photon source exploiting the emission of a semiconductor quantum dot (QD) located inside a photonic wire. Besides an excellent coupling (>95%) of QD spontaneous emission to the fundamental guided mode [1], we show that a single photon collection efficiency...

  1. Single photon emission and detection at the nanoscale utilizing semiconductor nanowires

    NARCIS (Netherlands)

    Reimer, M.E.; van Kouwen, M.P.; Barkelid, M., et al.

    2011-01-01

    We report recent progress toward on-chip single photon emission and detection in the near infrared utilizing semiconductor nanowires. Our single photon emitter is based on a single InAsP quantum dot embedded in a p-n junction defined along the growth axis of an InP nanowire. Under forward bias,

  2. Single photon emission and detection at the nanoscale utilizing semiconductor nanowires

    NARCIS (Netherlands)

    Reimer, M.E.; van Kouwen, M.P.; Barkelid, M., et al.

    2011-01-01

    We report recent progress toward on-chip single photon emission and detection in the near infrared utilizing semiconductor nanowires. Our single photon emitter is based on a single InAsP quantum dot embedded in a p-n junction defined along the growth axis of an InP nanowire. Under forward bias, ligh

  3. Performance limits of a single photon counting pixel system

    Science.gov (United States)

    Chmeissani, M.; Mikulec, B.

    2001-03-01

    X-ray imaging using hybrid pixel detectors in single photon counting mode is a relatively recent and exciting development. The photon counting mode implies that each pixel has a threshold in energy above which a hit is recorded. Sharing of charge between adjacent pixels would therefore lead to a loss of registered hits and for medical imaging applications to a higher patient dose. This explains why the demand for high spatial resolution and consequently small pixel sizes (<100 μm) motivates the Medipix2 collaboration to study the effects of charge sharing between pixels on system performance. Two different simulation codes are used to simulate the energy loss inside the detector and the charge transport towards the pixel electrodes. The largest contribution to the lateral spreading of charge comes from diffusion and can result in a considerable loss of detection efficiency in photon counting systems for small pixel sizes. The Medipix2 collaboration consists of groups from Barcelona, Cagliari, CEA/Leti DEIN, CERN, Freiburg, Glasgow, Mitthögskolan, Napoli, NIKHEF, MRC lab Cambridge, Pisa, Prague and Sassari.

  4. Superconducting nanowire single photon detectors for quantum information and communications

    CERN Document Server

    Wang, Zhen; Fujiwara, Mikio

    2010-01-01

    Superconducting nanowire single photon detectors (SNSPD or SSPD) are highly promising devices in the growing field of quantum information and communications technology. We have developed a practical SSPD system with our superconducting thin films and devices fabrication, optical coupling packaging, and cryogenic technology. The SSPD system consists of six-channel SSPD devices and a compact Gifford-McMahon (GM) cryocooler, and can operate continuously on 100 V ac power without the need for any cryogens. The SSPD devices were fabricated from high-quality niobium nitride (NbN) ultra-thin films that were epitaxially grown on single-crystal MgO substrates. The packaged SSPD devices were temperature stabilized to 2.96 K +/- 10 mK. The system detection efficiency for an SSPD device with an area of 20x20 $\\mu m^2$ was found to be 2.6% and 4.5% at wavelengths of 1550 and 1310 nm, respectively, at a dark count rate of 100 c/s, and a jitter of 100 ps full width at half maximum (FWHM). We also performed ultra-fast BB84 q...

  5. Polarization control of single photon quantum orbital angular momentum states.

    Science.gov (United States)

    Nagali, E; Sciarrino, F; De Martini, F; Piccirillo, B; Karimi, E; Marrucci, L; Santamato, E

    2009-10-12

    The orbital angular momentum of photons, being defined in an infinite-dimensional discrete Hilbert space, offers a promising resource for high-dimensional quantum information protocols in quantum optics. The biggest obstacle to its wider use is presently represented by the limited set of tools available for its control and manipulation. Here, we introduce and test experimentally a series of simple optical schemes for the coherent transfer of quantum information from the polarization to the orbital angular momentum of single photons and vice versa. All our schemes exploit a newly developed optical device, the so-called "q-plate", which enables the manipulation of the photon orbital angular momentum driven by the polarization degree of freedom. By stacking several q-plates in a suitable sequence, one can also have access to higher-order angular momentum subspaces. In particular, we demonstrate the control of the orbital angular momentum m degree of freedom within the subspaces of |m| = 2h and |m| = 4h per photon.

  6. Fano fluctuations in superconducting-nanowire single-photon detectors

    Science.gov (United States)

    Kozorezov, A. G.; Lambert, C.; Marsili, F.; Stevens, M. J.; Verma, V. B.; Allmaras, J. P.; Shaw, M. D.; Mirin, R. P.; Nam, Sae Woo

    2017-08-01

    Because of their universal nature, Fano fluctuations are expected to influence the response of superconducting-nanowire single-photon detectors (SNSPDs). We predict that photon counting rate (P C R ) as a function of bias current (IB) in SNSPDs is described by an integral over a transverse coordinate-dependent complementary error function. Fano fluctuations in the amount of energy deposited into the electronic system contribute to the finite width of this error function Δ IB . The local response of an SNSPD can also affect this width: the location of the initial photon absorption site across the width of the wire can impact the probability of vortex-antivortex unbinding and vortex entry from the edges. In narrow-nanowire SNSPDs, the local responses are uniform, and Fano fluctuations dominate Δ IB . We demonstrate good agreement between theory and experiments for a series of bath temperatures and photon energies in narrow-wire WSi SNSPDs. In a wide-nanowire device, the strong local dependence will introduce a finite width to the P C R curve, but with sharp cusps. We show how Fano fluctuations can smooth these features to produce theoretical curves that better match experimental data. We also show that the time-resolved hotspot relaxation curves predicted by Fano fluctuations match the previously measured Lorentzian shapes (except for their tails) over the entire range of bias currents investigated experimentally.

  7. Collective magnetic splitting in single-photon superradiance

    CERN Document Server

    Kong, Xiangjin

    2016-01-01

    In an ensemble of identical atoms, cooperative effects like sub- or superradiance may alter the decay rates and the energy of specific transitions may be shifted from the single-atom value by the so-called collective Lamb shift. So far, one has considered these effects in ensembles of two-level systems only. In this work we show that in a system with atoms or nuclei under the action of an external magnetic field, an additional, so far unaccounted for collective contribution to the level shifts appears that can amount to seizable deviations from the single-atom Zeeman or magnetic hyperfine splitting. We develop a formalism to describe single-photon superradiance in multi-level systems and quantify the parameter regime for which the collective Lamb shift leads to measurable deviations in the magnetic-field-induced splitting. In particular, we show that this effect should be observable in the nuclear magnetic hyperfine splitting in M\\"ossbauer nuclei embedded in thin-film x-ray cavities.

  8. Optimized Superconducting Nanowire Single Photon Detectors to Maximize Absorptance

    CERN Document Server

    Csete, Maria; Szenes, Andras; Banhelyi, Balazs; Csendes, Tibor; Szabo, Gabor

    2015-01-01

    Dispersion characteristics of four types of superconducting nanowire single photon detectors, nano-cavity-array- (NCA-), nano-cavity-deflector-array- (NCDA-), nano-cavity-double-deflector-array- (NCDDA-) and nano-cavity-trench-array- (NCTA-) integrated (I-A-SNSPDs) devices was optimized in three periodicity intervals commensurate with half-, three-quarter- and one SPP wavelength. The optimal configurations capable of maximizing NbN absorptance correspond to periodicity dependent tilting in S-orientation (90{\\deg} azimuthal orientation). In NCAI-A-SNSPDs absorptance maxima are reached at the plasmonic Brewster angle (PBA) due to light tunneling. The absorptance maximum is attained in a wide plasmonic-pass-band in NCDAI_1/2*lambda-A, inside a flat-plasmonic-pass-band in NCDAI_3/4*lambda-A and inside a narrow plasmonic-band in NCDAI_lambda-A. In NCDDAI_1/2*lambda-A bands of strongly-coupled cavity and plasmonic modes cross, in NCDDAI_3/4*lambda-A an inverted-plasmonic-band-gap develops, while in NCDDAI_lambda-A ...

  9. A Search for Single Photon Events in Neutrino Interactions

    CERN Document Server

    Kullenberg, C.T.; Dimmery, D.; Tian, X.C.; Autiero, D.; Gninenko, S.; Rubbia, A.; Alekhin, S.; Astier, P.; Baldisseri, A.; Baldo-Ceolin, M.; Banner, M.; Bassompierre, G.; Benslama, K.; Besson, N.; Bird, I.; Blumenfeld, B.; Bobisut, F.; Bouchez, J.; Boyd, S.; Bueno, A.; Bunyatov, S.; Camilleri, L.; Cardini, A.; Cattaneo, P.W.; Cavasinni, V.; Cervera-Villanueva, A.; Challis, R.; Chukanov, A.; Collazuol, G.; Conforto, G.; Conta, C.; Contalbrigo, M.; Cousins, R.; Degaudenzi, H.; De Santo, A.; Del Prete, T.; Di Lella, L.; do Couto e Silva, E.; Dumarchez, J.; Ellis, M.; Feldman, G.J.; Ferrari, R.; Ferrère, D.; Flaminio, V.; Fraternali, M.; Gaillard, J.-M.; Gangler, E.; Geiser, A.; Geppert, D.; Gibin, D.; Godley, A.; Gomez-Cadenas, J.-J.; Gosset, J.; Gößling, C.; Gouanère, M.; Grant, A.; Graziani, G.; Guglielmi, A.; Hagner, C.; Hernando, J.; Hurst, P.; Hyett, N.; Iacopini, E.; Joseph, C.; Juget, F.; Kent, N.; Klimov, O.; Kokkonen, J.; Kovzelev, A.; Krasnoperov, A.; Kim, J.J.; Kirsanov, M.; Kulagin, S.; Lacaprara, S.; Lachaud, C.; Lakić, B.; Lanza, A.; La Rotonda, L.; Laveder, M.; Letessier-Selvon, A.; Levy, J.M.; Ling, J.; Linssen, L.; Ljubičic, A.; Long, J.; Lupi, A.; Lyubushkin, V.; Marchionni, A.; Martelli, F.; Méchain, X.; Mendiburu, J.-P.; Meyer, J.-P.; Mezzetto, M.; Moorhead, G.F.; Naumov, D.; Nédélec, P.; Nefedov, Yu.; Nguyen-Mau, C.; Orestano, D.; Pastore, F.; Peak, L.S.; Pennacchio, E.; Pessard, H.; Petti, R.; Placci, A.; Polesello, G.; Pollmann, D.; Polyarush, A.; Poulsen, C.; Popov, B.; Rebuffi, L.; Rico, J.; Riemann, P.; Roda, C.; Salvatore, F.; Samoylov, O.; Schahmaneche, K.; Schmidt, B.; Schmidt, T.; Sconza, A.; Scott, A.M.; Seaton, M.B.; Sevior, M.; Sillou, D.; Soler, F.J.P.; Sozzi, G.; Steele, D.; Stiegler, U.; Stipčević, M.; Stolarczyk, Th.; Tareb-Reyes, M.; Taylor, G.N.; Tereshchenko, V.; Toropin, A.; Touchard, A.-M.; Tovey, S.N.; Tran, M.-T.; Tsesmelis, E.; Ulrichs, J.; Vacavant, L.; Valdata-Nappi, M.; Valuev, V.; Vannucci, F.; Varvell, K.E.; Veltri, M.; Vercesi, V.; Vidal-Sitjes, G.; Vieira, J.-M.; Vinogradova, T.; Weber, F.V.; Weisse, T.; Wilson, F.F.; Winton, L.J.; Wu, Q.; Yabsley, B.D.; Zaccone, H.; Zuber, K.; Zuccon, P.

    2012-01-01

    We present a search for neutrino-induced events containing a single, exclusive photon using data from the NOMAD experiment at the CERN SPS where the average energy of the neutrino flux is $\\simeq 25$ GeV. The search is motivated by an excess of electron-like events in the 200--475 MeV energy region as reported by the MiniBOONE experiment. In NOMAD, photons are identified via their conversion to $e^+e^-$ in an active target embedded in a magnetic field. The background to the single photon signal is dominated by the asymmetric decay of neutral pions produced either in a coherent neutrino-nucleus interaction, or in a neutrino-nucleon neutral current deep inelastic scattering, or in an interaction occurring outside the fiducial volume. All three backgrounds are determined {\\it in situ} using control data samples prior to opening the `signal-box'. In the signal region, we observe {\\bf 155} events with a predicted background of {\\bf 129.2 $\\pm$ 8.5 $\\pm$ 3.3}. We interpret this as null evidence for excess of single...

  10. Avalanche photodiodes and quenching circuits for single-photon detection.

    Science.gov (United States)

    Cova, S; Ghioni, M; Lacaita, A; Samori, C; Zappa, F

    1996-04-20

    Avalanche photodiodes, which operate above the breakdown voltage in Geiger mode connected with avalanche-quenching circuits, can be used to detect single photons and are therefore called singlephoton avalanche diodes SPAD's. Circuit configurations suitable for this operation mode are critically analyzed and their relative merits in photon counting and timing applications are assessed. Simple passive-quenching circuits (PQC's), which are useful for SPAD device testing and selection, have fairly limited application. Suitably designed active-quenching circuits (AQC's) make it possible to exploit the best performance of SPAD's. Thick silicon SPAD's that operate at high voltages (250-450 V) have photon detection efficiency higher than 50% from 540- to 850-nm wavelength and still ~3% at 1064 nm. Thin silicon SPAD's that operate at low voltages (10-50 V) have 45% efficiency at 500 nm, declining to 10% at 830 nm and to as little as 0.1% at 1064 nm. The time resolution achieved in photon timing is 20 ps FWHM with thin SPAD's; it ranges from 350 to 150 ps FWHM with thick SPAD's. The achieved minimum counting dead time and maximum counting rate are 40 ns and 10 Mcps with thick silicon SPAD's, 10 ns and 40 Mcps with thin SPAD's. Germanium and III-V compound semiconductor SPAD's extend the range of photon-counting techniques in the near-infrared region to at least 1600-nm wavelength.

  11. On single-photon ultraviolet ablation of polymeric materials

    Science.gov (United States)

    Cain, Stephen R.; Burns, F. C.; Otis, C. E.

    1992-05-01

    The nature of uv ablation of organic polymers is discussed in terms of a pseudo-zeroth-order rate law of the form dx/dt = k0e-(Eact/kT), where Eact is assumed to be the strength of the weakest bonds in the polymer and T is the local temperature increase from the incident laser pulse. Equations derived from previous models that assumed nonthermal photodecomposition were duplicated from this photothermal model. Even for the simple case of single-photon absorption, nonideal behavior is affected by radiationless decay, pulse length, and thermal diffusion. These effects were probed. Results indicated that thermal diffusion may have a significant effect on the threshold fluence and to some degree on the shape of the etch depth versus fluence curve. Absorption dynamics (saturation and radiationless decay) appear to be the dominant factor in determining the functional dependence of etch depth on fluence. As a result of competition between absorption saturation and radiationless decay, the penetration depth is intensity dependent. High fluence as well as short temporal pulses (subnanosecond) penetrate more deeply into the polymer than predicted by simple Beer's law absorption. The apparent existence of an optimum pulse length, for a given absorbing system, is another result of the absorption dynamics.

  12. Photon-efficient imaging with a single-photon camera

    Science.gov (United States)

    Shin, Dongeek; Xu, Feihu; Venkatraman, Dheera; Lussana, Rudi; Villa, Federica; Zappa, Franco; Goyal, Vivek K.; Wong, Franco N. C.; Shapiro, Jeffrey H.

    2016-06-01

    Reconstructing a scene's 3D structure and reflectivity accurately with an active imaging system operating in low-light-level conditions has wide-ranging applications, spanning biological imaging to remote sensing. Here we propose and experimentally demonstrate a depth and reflectivity imaging system with a single-photon camera that generates high-quality images from ~1 detected signal photon per pixel. Previous achievements of similar photon efficiency have been with conventional raster-scanning data collection using single-pixel photon counters capable of ~10-ps time tagging. In contrast, our camera's detector array requires highly parallelized time-to-digital conversions with photon time-tagging accuracy limited to ~ns. Thus, we develop an array-specific algorithm that converts coarsely time-binned photon detections to highly accurate scene depth and reflectivity by exploiting both the transverse smoothness and longitudinal sparsity of natural scenes. By overcoming the coarse time resolution of the array, our framework uniquely achieves high photon efficiency in a relatively short acquisition time.

  13. Room temperature mid-IR single photon spectral imaging

    CERN Document Server

    Dam, Jeppe Seidelin; Tidemand-Lichtenberg, Peter

    2012-01-01

    Spectral imaging and detection of mid-infrared (mid-IR) wavelengths are emerging as an enabling technology of great technical and scientific interest; primarily because important chemical compounds display unique and strong mid-IR spectral fingerprints revealing valuable chemical information. While modern Quantum cascade lasers have evolved as ideal coherent mid-IR excitation sources, simple, low noise, room temperature detectors and imaging systems still lag behind. We address this need presenting a novel, field-deployable, upconversion system for sensitive, 2-D, mid-IR spectral imaging. Measured room temperature dark noise is 0.2 photons/spatial element/second, which is a billion times below the dark noise level of cryogenically cooled InSb cameras. Single photon imaging and up to 200 x 100 spatial elements resolution is obtained reaching record high continuous wave quantum efficiency of about 20 % for polarized incoherent light at 3 \\mum. The proposed method is relevant for existing and new mid-IR applicat...

  14. Characterization of a Spontaneous Parametric Downconversion Source for Use in Single Photon Tests of Quantum Mechanics

    Science.gov (United States)

    Alexander, Preston; McDonld, Jackson; Harrington, Jason; Smith, R. Seth

    2014-03-01

    During the past year, a quantum optics laboratory was constructed and tested at Francis Marion University. A spontaneous parametric downconversion source was used to create pairs of correlated photons for use in single photon tests of quantum mechanics. Photons from a spontaneous parametric downconversion source were detected with single photon counting modules that were purchased through the Advanced Laboratory Physics Association (ALPHA). The effect of pump polarization on the output intensity was studied. Coincidences between pairs of correlated photons were counted and plotted as a function of the angle between the single photon detectors, in order to perform a test of Conservation of Momentum. The laboratory will be used to perform single photon tests of quantum mechanics, including the Grangier experiment, single photon interference, quantum state measurement, and tests of local realism.

  15. Observation of non-diffracting behavior at the single-photon level

    CERN Document Server

    Cruz-Ramirez, Hector; Morelos, Francisco J; Quinto-Su, Pedro A; Gutierrez-Vega, Julio C; U'Ren, Alfred B

    2013-01-01

    We demonstrate the generation of non-diffracting heralded single photons, i.e. which are characterized by a single-photon transverse intensity distribution which remains essentially unchanged over a significant propagation distance. For this purpose we have relied on the process of spontaneous parametric downconversion (SPDC) for the generation of signal and idler photon pairs, where our SPDC crystal is pumped by a Bessel-Gauss (BG) beam. Our experiment shows that the well-understood non-diffracting behavior of a BG beam may be directly mapped to the signal-mode, single photons heralded by the detection of a single idler photon. In our experiment, the heralded single photon is thus arranged to be non-diffracting without the need for projecting its single-photon transverse amplitude, post-generation, in any manner.

  16. Pulsed single-photon spectrograph by frequency-to-time mapping using chirped fiber Bragg gratings

    CERN Document Server

    Davis, Alex O C; Karpinski, Michal; Smith, Brian J

    2016-01-01

    A fiber-integrated spectrograph for single-photon pulses based upon frequency-to-time mapping, implemented by chromatic group delay dispersion (GDD), and precise temporally-resolved single photon counting is presented. A chirped fiber Bragg grating provides low-loss GDD mapping the frequency distribution of an input pulse onto the temporal envelope of the output pulse. Time-resolved detection with fast single-photon-counting modules enables the monitoring of the 825 nm to 835 nm wavelength range with nearly uniform efficiency with 55 pm resolution (24 GHz at 830 nm). To demonstrate the versatility of this technique spectral interference of heralded single photons and the joint spectral intensity distribution of a photon-pair source are measured. This approach to single-photon-level spectral measurements provides a route to realize applications of time-frequency quantum optics at visible and near-infrared wavelengths, where multiple spectral channels must be simultaneously monitored.

  17. Quick single-photon detector with many avalanche photo diodes working on the time division

    Institute of Scientific and Technical Information of China (English)

    Jian Peng; Yifei Fu; Li Yao; Xudong Shang; Zhixin Lu; Bojun Yang; Li Yu

    2008-01-01

    Due to the limit of response speed of the present single-photon detector, the code rate is still too low to come into practical use for the present quantum key distribution (QKD) system.A new idea is put up to design a quick single-photon detector.This quick single-photon detector is composed of a multi-port optic-fiber splitter and many avalanche photo diodes (APDs).Au of the ports with APDs work on the time division and cooperate with a logic discriminating and deciding unit driven by the clock signal.The operation frequency lies on the number N of ports, and can reach N times of the conventional single-photon detector.The single-photon prompt detection can come true for high repetition-rate pulses.The applying of this detector will largely raise the code rate of the QKD, and boost the commercial use.

  18. A high resolution laser ranging system based on time-correlated single-photon counting technology

    Science.gov (United States)

    Yang, Yixin; Wang, Huanqin; Huang, Zhe; Cao, Yangyang; Gui, Huaqiao

    2014-12-01

    Laser ranging has become an important method for both distance measurements and acquisition of threedimensional (3D) images. In this paper, a laser ranging system based on Time-Correlated Single-Photon Counting technology (TCSPC) is developed. A Geiger-mode avalanche photodiode (G-APD), which has the ability of detecting single-photon events, is used to capture the weak light scattered from the long-range target. In order to improve the ranging resolution of TCSPC based measurement system, a high repetition frequency of subnanosecond narrow pulse generator circuit based on the avalanche effect of RF-BJT is designed and applied as the light source. Moreover, some optimized optical light designs have been done to improve the system signal to noise rate (SNR), including using a special aspherical lens as projecting lens, adopting a telephoto camera lens with small view angle and short depth of field before detector. Experimental tests for evaluation of the laser raging system performance are described. As a means of echo signal analysis, three different algorithms have been introduced, in which the cross-correlation algorithm was demonstrated to be the most effective algorithm to determining the round trip time to a target, even based on histograms with a significant amount of background noise photons. It was found that centimeter ranging resolution can be achieved thanks to the use of Time-to-Digital Converter (TDC) with picosecond resolution and the Cross-Correlation algorithm. The proposed laser ranging system has advantages of high range resolution, short response time and simple structure, which was potential applications for 3D object recognition, computer vision, reverse engineering and virtual reality.

  19. Preoperative nodal staging of non-small cell lung cancer using {sup 99m}Tc-sestamibi SPECT/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Miziara, Juliana Muniz; Rocha, Euclides Timoteo da; Miziara, Jose Elias Abrao; Garcia, Gustavo Fabene; Simoes, Maria Izilda Previato; Lopes, Marco Antonio; Kerr, Ligia Maria [Hospital de Cancer de Barretos, Barretos, SP (Brazil); Buchpiguel, Carlos Alberto, E-mail: julimiziara@ig.com.br [Faculdade de Medicina da Universidade da Sao Paulo, Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, SP (Brazil)

    2011-07-01

    Objectives: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using {sup 99m}Tc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. Methods: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with {sup 99m}Tc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. Results: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for {sup 99m}Tc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative

  20. Life, evolution, and the pursuit of single photon sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Bitensky, M.W.; Whalen, M.M.; Torney, D.C. (Los Alamos National Lab., NM (USA))

    1988-01-01

    Evolutionary forces have designed a large family of rod and cone photoreceptors, each member of which suits the lifestyle requirements and circadian patterns of a particular species. The three-segment architecture of signal transduction is conspicuous in the biochemistry of photoreceptors and supports their demonstrated properties of extreme sensitivity, low noise levels, extended dynamic range, and light adaptation. The designs elaborated by evolution reflect a gradual process of modification, with the sequential elaboration of layers of control and refinements in control. The end results of this long evolutionary labor are the functional efficiency and dynamic range that give the rod its utility. Our conceptual problems in deriving observed rod properties from the collective features of known rod gene products may well give way when we have learned more about the true composition and topology of the outer segment gene set and both bound and free nucleotide concentrations. The invertebrates have developed alternative solutions to the problems of photoreceptor sensitivity and wide dynamic range. The vertebrate rod represents a truly optimized way to capture and interpret low-intensity photon signals. One may anticipate, with some enthusiasm, those molecular and kinetic data that will permit an understanding of how cones differ from rods and how release from the requirement for single photon detection has shaped the design of this wavelength-specific companion photoreceptor. The utilization by evolution of the three-segment architecture of GTP-dependent signal transduction for other modalities of sensory perception, such as olfaction and gustation is certainly a reasonable and successful choice. 56 references.

  1. Tomography of a Mode-Tunable Coherent Single-Photon Subtractor

    Science.gov (United States)

    Ra, Young-Sik; Jacquard, Clément; Dufour, Adrien; Fabre, Claude; Treps, Nicolas

    2017-07-01

    Single-photon subtraction plays important roles in optical quantum information processing as it provides a non-Gaussian characteristic in continuous-variable quantum information. While the conventional way of implementing single-photon subtraction based on a low-reflectance beam splitter works properly for a single-mode quantum state, it is unsuitable for a multimode quantum state because a single photon is subtracted from all multiple modes without maintaining their mode coherence. Here, we experimentally implement and characterize a mode-tunable coherent single-photon subtractor based on sum-frequency generation. It can subtract a single photon exclusively from one desired time-frequency mode of light or from a coherent superposition of multiple time-frequency modes. To experimentally characterize the time-frequency modes of the single-photon subtractor, we employ quantum process tomography based on coherent states. The mode-tunable coherent single-photon subtractor will be an essential element for realizing non-Gaussian quantum networks necessary to get a quantum advantage in information processing.

  2. EQUIPMENTS TO SINGLE PHOTON REGISTRATION. PART 1. FEATURES AND POSSIBILITIES OF MULTI-CHANNEL PHOTODETECTORS WITH INTRINSIC AMPLIFICATION. (REVIEW

    Directory of Open Access Journals (Sweden)

    O. V. Dvornikov

    2012-01-01

    Full Text Available The main types of the modern photo detectors applied to single photon registration are analyzed. It is offered to use silicon photomultipliers for production of multi-channel optoelectronic systems with the single photon resolution.

  3. Low-noise low-jitter 32-pixels CMOS single-photon avalanche diodes array for single-photon counting from 300 nm to 900 nm

    Energy Technology Data Exchange (ETDEWEB)

    Scarcella, Carmelo; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Villa, Federica; Tisa, Simone; Zappa, Franco [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy)

    2013-12-15

    We developed a single-photon counting multichannel detection system, based on a monolithic linear array of 32 CMOS SPADs (Complementary Metal-Oxide-Semiconductor Single-Photon Avalanche Diodes). All channels achieve a timing resolution of 100 ps (full-width at half maximum) and a photon detection efficiency of 50% at 400 nm. Dark count rate is very low even at room temperature, being about 125 counts/s for 50 μm active area diameter SPADs. Detection performance and microelectronic compactness of this CMOS SPAD array make it the best candidate for ultra-compact time-resolved spectrometers with single-photon sensitivity from 300 nm to 900 nm.

  4. Effective Single Photon Decay Mode of Positronium Decay via Electroweak Interactions

    CERN Document Server

    Pérez-Ríos, Jesús

    2015-01-01

    We consider the decay of positronium to a neutrino-antineutrino accompanied by a single photon. Since the neutrino pair go undetected, this appears as a single photon decay of positronium. These decay channel are mediated through the exchange of the massive $W$ and $Z$ vector bosons of the electroweak interaction. After summing over the various neutrino channels, the standard model calculation yields the rate for such a single photon decay process of $\\Gamma_{Ps \\rightarrow \\gamma}$ = 1.72 $\\times 10^{-19}$ s$^{-1}$.

  5. Experimental open-air quantum key distribution with a single-photon source

    Energy Technology Data Exchange (ETDEWEB)

    Alleaume, R [Laboratoire de Photonique Quantique et Moleculaire, UMR 8537 du CNRS, ENS Cachan, 61 avenue du President Wilson, 94235 Cachan Cedex (France); Treussart, F [Laboratoire de Photonique Quantique et Moleculaire, UMR 8537 du CNRS, ENS Cachan, 61 avenue du President Wilson, 94235 Cachan Cedex (France); Messin, G [Laboratoire Charles Fabry de l' Institut d' Optique, UMR 8501 du CNRS, F-91403 Orsay (France); Dumeige, Y [Laboratoire de Photonique Quantique et Moleculaire, UMR 8537 du CNRS, ENS Cachan, 61 avenue du President Wilson, 94235 Cachan Cedex (France); Roch, J-F [Laboratoire de Photonique Quantique et Moleculaire, UMR 8537 du CNRS, ENS Cachan, 61 avenue du President Wilson, 94235 Cachan Cedex (France); Beveratos, A [Laboratoire Charles Fabry de l' Institut d' Optique, UMR 8501 du CNRS, F-91403 Orsay (France); Brouri-Tualle, R [Laboratoire Charles Fabry de l' Institut d' Optique, UMR 8501 du CNRS, F-91403 Orsay (France); Poizat, J-P [Laboratoire Charles Fabry de l' Institut d' Optique, UMR 8501 du CNRS, F-91403 Orsay (France); Grangier, P [Laboratoire Charles Fabry de l' Institut d' Optique, UMR 8501 du CNRS, F-91403 Orsay (France)

    2004-07-01

    We describe the implementation of a quantum key distribution (QKD) system using a single-photon source, operating at night in open air. The single-photon source at the heart of the functional and reliable set-up relies on the pulsed excitation of a single nitrogen-vacancy colour centre in a diamond nanocrystal. We tested the effect of attenuation on the polarized encoded photons for inferring the longer distance performance of our system. For strong attenuation, the use of pure single-photon states gives measurable advantage over systems relying on weak attenuated laser pulses. The results are in good agreement with theoretical models developed to assess QKD security.

  6. Room temperature triggered single-photon source in the near infrared

    Energy Technology Data Exchange (ETDEWEB)

    Wu, E [Laboratoire de Photonique Quantique et Moleculaire, UMR CNRS 8537, Ecole Normale Superieure de Cachan (France); Rabeau, J R [Department of Physics, Macquarie University, Sydney, New South Wales 2109 (Australia); Roger, G [Laboratoire Charles Fabry de l' Institut d' Optique, UMR CNRS 8501, Palaiseau (France); Treussart, F [Laboratoire de Photonique Quantique et Moleculaire, UMR CNRS 8537, Ecole Normale Superieure de Cachan (France); Zeng, H [State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062, China (China); Grangier, P [Laboratoire Charles Fabry de l' Institut d' Optique, UMR CNRS 8501, Palaiseau (France); Prawer, S [Centre of Excellence for Quantum Computer Technology and Quantum Communications Victoria, School of Physics, University of Melbourne, Victoria 3010 (Australia); Roch, J-F [Laboratoire de Photonique Quantique et Moleculaire, UMR CNRS 8537, Ecole Normale Superieure de Cachan (France)

    2007-12-15

    We report the realization of a solid-state triggered single-photon source with narrow emission in the near infrared at room temperature. It is based on the photoluminescence of a single nickel-nitrogen NE8 colour centre in a chemical vapour deposited diamond nanocrystal. Stable single-photon emission has been observed in the photoluminescence under both continuous-wave and pulsed excitations. The realization of this source represents a step forward in the application of diamond-based single-photon sources to quantum key distribution (QKD) under practical operating conditions.

  7. Experimental open air quantum key distribution with a single photon source

    CERN Document Server

    Alleaume, R; Brouri-Tualle, R; Dumeige, Y; Messin, G; Poizat, J P; Roch, J F; Treussart, F; Alleaume, Romain; Beveratos, Alexios; Brouri-Tualle, Rosa; Dumeige, Yannick; Messin, Gaetan; Poizat, Jean-Philippe; Proxy, Philippe Grangier; Roch, Jean-Francois; Treussart, Francois; ccsd-00001148, ccsd

    2004-01-01

    We present a full implementation of a quantum key distribution (QKD) system with a single photon source, operating at night in open air. The single photon source at the heart of the functional and reliable setup relies on the pulsed excitation of a single nitrogen-vacancy color center in diamond nanocrystal. We tested the effect of attenuation on the polarized encoded photons for inferring longer distance performance of our system. For strong attenuation, the use of pure single photon states gives measurable advantage over systems relying on weak attenuated laser pulses. The results are in good agreement with theoretical models developed to assess QKD security.

  8. A highly efficient single-photon source based on a quantum dot in a photonic nanowire

    DEFF Research Database (Denmark)

    Claudon, Julien; Bleuse, Joel; Malik, Nitin Singh

    2010-01-01

    The development of efficient solid-state sources of single photons is a major challenge in the context of quantum communication,optical quantum information processing and metrology1. Such a source must enable the implementation of a stable, single-photon emitter, like a colour centre in diamond2...... with carefully tailored ends13. Under optical pumping, we demonstrate a record source efficiency of 0.72, combined with pure single-photon emission. This non-resonant approach also provides broadband spontaneous emission control, thus offering appealing novel opportunities for the development of single...

  9. Quantum information-holding single-photon router based on spontaneous emission

    Science.gov (United States)

    Yan, GuoAn; Qiao, HaoXue; Lu, Hua; Chen, AiXi

    2017-09-01

    In this paper, we propose a single-photon router via the use of a four-level atom system coupled with two one-dimensional coupled-resonator waveguides. A single photon can be directed from one quantum channel into another by atomic spontaneous emission. The coherent resonance and the photonic bound states lead to the perfect reflection appearing in the incident channel. The fidelity of the atom is related to the magnitude of the coupling strength and can reach unit when the coupling strength matches g a = g b . This shows that the transfer of a single photon into another quantum channel has no influence on the fidelity at special points.

  10. Quantum dot resonant tunneling diode single photon detector with aluminum oxide aperture defined tunneling area

    DEFF Research Database (Denmark)

    Li, H.W.; Kardynal, Beata; Ellis, D.J.P.

    2008-01-01

    Quantum dot resonant tunneling diode single photon detector with independently defined absorption and sensing areas is demonstrated. The device, in which the tunneling is constricted to an aperture in an insulating layer in the emitter, shows electrical characteristics typical of high quality...... resonant tunneling diodes. A single photon detection efficiency of 2.1%+/- 0.1% at 685 nm was measured corresponding to an internal quantum efficiency of 14%. The devices are simple to fabricate, robust, and show promise for large absorption area single photon detectors based on quantum dot structures....

  11. A novel high-efficiency single-mode quantum dot single photon source

    DEFF Research Database (Denmark)

    Gerard, J.M.; Gregersen, Niels; Nielsen, Torben Roland

    2008-01-01

    We present a novel single-mode single photon source exploiting the emission of a semiconductor quantum dot (QD) located inside a photonic wire. Besides an excellent coupling (>95%) of QD spontaneous emission to the fundamental guided mode [1], we show that a single photon collection efficiency...... above 80% within a 0.5 numerical aperture can be achieved using a bottom Bragg mirror and a tapering of the nanowire tip. Because this photon collection strategy does not exploit the Purcell effect, it could also be efficiently applied to broadband single photon emitters such as F-centers in diamond....

  12. Multigate single-photon detection and timing discrimination with an InGaAs/lnP avalanche photodiode.

    Science.gov (United States)

    Zhou, Chunyuan; Wu, Guang; Zeng, Heping

    2006-03-10

    Multigate detection of single photons at 1550 nm is achieved by using capacitor-balanced InGaAs/InP avalanche photodiodes, with which we experimentally demonstrate the efficient discrimination of single-photon timing by counting single-photon clicks and the corresponding afterpulses within the multiple gates. Results show that the technique of multigate detection is a practical method for the single-photon timing information process.

  13. Ultra-bright and efficient single photon generation based on N-V centres in nanodiamonds on a solid immersion lens

    CERN Document Server

    Schröder, Tim; Banholzer, Moritz Julian; Benson, Oliver

    2010-01-01

    Single photons are fundamental elements for quantum information technologies such as quantum cryptography, quantum information storage and optical quantum computing. Colour centres in diamond have proven to be stable single photon sources and thus essential components for reliable and integrated quantum information technology. A key requirement for such applications is a large photon flux and a high efficiency. Paying tribute to various attempts to maximise the single photon flux we show that collection efficiencies of photons from colour centres can be increased with a rather simple experimental setup. To do so we spin-coated nanodiamonds containing single nitrogen-vacancy colour centres on the flat surface of a ZrO2 solid immersion lens. We found stable single photon count rates of up to 853 kcts/s at saturation under continuous wave excitation while having excess to more than 100 defect centres with count rates from 400 kcts/s to 500 kcts/s. For a blinking defect centre we found count rates up to 2.4 Mcts/...

  14. NFAD Arrays for Single Photon Optical Communications at 1.5 um Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For this program, we propose to develop large pixel-count single photon counting detector arrays suitable for deployment in spacecraft terminal receivers supporting...

  15. Ultrafast room temperature single-photon source from nanowire-quantum dots.

    Science.gov (United States)

    Bounouar, S; Elouneg-Jamroz, M; Hertog, M den; Morchutt, C; Bellet-Amalric, E; André, R; Bougerol, C; Genuist, Y; Poizat, J-Ph; Tatarenko, S; Kheng, K

    2012-06-13

    Epitaxial semiconductor quantum dots are particularly promising as realistic single-photon sources for their compatibility with manufacturing techniques and possibility to be implemented in compact devices. Here, we demonstrate for the first time single-photon emission up to room temperature from an epitaxial quantum dot inserted in a nanowire, namely a CdSe slice in a ZnSe nanowire. The exciton and biexciton lines can still be resolved at room temperature and the biexciton turns out to be the most appropriate transition for single-photon emission due to a large nonradiative decay of the bright exciton to dark exciton states. With an intrinsically short radiative decay time (≈300 ps) this system is the fastest room temperature single-photon emitter, allowing potentially gigahertz repetition rates.

  16. On-chip low loss heralded source of pure single photons

    CERN Document Server

    Spring, Justin B; Metcalf, Benjamin J; Humphreys, Peter C; Moore, Merritt; Thomas-Peter, Nicholas; Barbieri, Marco; Jin, Xian-Min; Langford, Nathan K; Kolthammer, W Steven; Booth, Martin J; Walmsley, Ian A

    2013-01-01

    A key obstacle to the experimental realization of many photonic quantum-enhanced technologies is the lack of low-loss sources of single photons in pure quantum states. We demonstrate a promising solution: generation of heralded single photons in a silica photonic chip by spontaneous four-wave mixing. A heralding efficiency of 40%, corresponding to a preparation efficiency of 80% accounting for detector performance, is achieved due to efficient coupling of the low-loss source to optical fibers. A single photon purity of 0.86 is measured from the source number statistics without filtering, and confirmed by direct measurement of the joint spectral intensity. We calculate that similar high-heralded-purity output can be obtained from visible to telecom spectral regions using this approach. On-chip silica sources can have immediate application in a wide range of single-photon quantum optics applications which employ silica photonics.

  17. Sine wave gating silicon single-photon detectors for multiphoton entanglement experiments

    Science.gov (United States)

    Zhou, Nan; Jiang, Wen-Hao; Chen, Luo-Kan; Fang, Yu-Qiang; Li, Zheng-Da; Liang, Hao; Chen, Yu-Ao; Zhang, Jun; Pan, Jian-Wei

    2017-08-01

    Silicon single-photon detectors (SPDs) are the key devices for detecting single photons in the visible wavelength range. Here we present high detection efficiency silicon SPDs dedicated to the generation of multiphoton entanglement based on the technique of high-frequency sine wave gating. The silicon single-photon avalanche diode components are acquired by disassembling 6 commercial single-photon counting modules (SPCMs). Using the new quenching electronics, the average detection efficiency of SPDs is increased from 68.6% to 73.1% at a wavelength of 785 nm. These sine wave gating SPDs are then applied in a four-photon entanglement experiment, and the four-fold coincidence count rate is increased by 30% without degrading its visibility compared with the original SPCMs.

  18. Bright single photon emission from a quantum dot in a circular Bragg grating microcavity

    CERN Document Server

    Ates, Serkan; Davanco, Marcelo; Badolato, Antonio; Srinivasan, Kartik

    2011-01-01

    Bright single photon emission from single quantum dots in suspended circular Bragg grating microcavities is demonstrated. This geometry has been designed to achieve efficient (> 50 %) single photon extraction into a near-Gaussian shaped far-field pattern, modest (~10x) Purcell enhancement of the radiative rate, and a spectral bandwidth of a few nanometers. Measurements of fabricated devices show progress towards these goals, with collection efficiencies as high as ~10% demonstrated with moderate spectral bandwidth and rate enhancement. Photon correlation measurements are performed under above-bandgap excitation (pump wavelength = 780 nm to 820 nm) and confirm the single photon character of the collected emission. While the measured sources are all antibunched and dominantly composed of single photons, the multi-photon probability varies significantly. Devices exhibiting tradeoffs between collection efficiency, Purcell enhancement, and multi-photon probability are explored and the results are interpreted with ...

  19. Corpuscular model of two-beam interference and double-slit experiments with single photons

    CERN Document Server

    Jin, Fengping; De Raedt, Hans; Michielsen, Kristel; Miyashita, Seiji

    2010-01-01

    We introduce an event-based corpuscular simulation model that reproduces the wave mechanical results of single-photon double slit and two-beam interference experiments and (of a one-to-one copy of an experimental realization) of a single-photon interference experiment with a Fresnel biprism. The simulation comprises models that capture the essential features of the apparatuses used in the experiment, including the single-photon detectors recording individual detector clicks. We demonstrate that incorporating in the detector model, simple and minimalistic processes mimicking the memory and threshold behavior of single-photon detectors is sufficient to produce multipath interference patterns. These multipath interference patterns are built up by individual particles taking one single path to the detector where they arrive one-by-one. The particles in our model are not corpuscular in the standard, classical physics sense in that they are information carriers that exchange information with the apparatuses of the ...

  20. A bright on-demand source of indistinguishable single photons at telecom wavelengths

    CERN Document Server

    Kim, Je-Hyung; Richardson, Christopher J K; Leavitt, Richard P; Waks, Edo

    2015-01-01

    Long-distance quantum communication relies on the ability to efficiently generate and prepare single photons at telecom wavelengths. In many applications these photons must also be indistinguishable such that they exhibit interference on a beamsplitter, which implements effective photon-photon interactions. However, deterministic generation of indistinguishable single photons with high brightness remains a challenging problem. We demonstrate a telecom wavelength source of indistinguishable single photons using an InAs/InP quantum dot in a nanophotonic cavity. The cavity enhances the quantum dot emission, resulting in a nearly Gaussian transverse mode profile with high out-coupling efficiency exceeding 46%, leading to detected photon count rates that would exceed 1.5 million counts per second. We also observe Purcell enhanced spontaneous emission rate as large as 4. Using this source, we generate linearly polarized, high purity single photons at telecom-wavelength and demonstrate the indistinguishable nature o...

  1. Analysis of Photonic Quantum Nodes Based on Deterministic Single-Photon Raman Passage

    CERN Document Server

    Rosenblum, Serge

    2014-01-01

    The long-standing goal of deterministically controlling a single photon using another was recently realized in various experimental settings. Among these, a particularly attractive demonstration relied on deterministic single-photon Raman passage in a three-level Lambda system coupled to a single-mode waveguide. Beyond the ability to control the direction of propagation of one photon by the direction of another photon, this scheme can also perform as a passive quantum memory and a universal quantum gate. Relying on interference, this all-optical, coherent scheme requires no additional control fields, and can therefore form the basis for scalable quantum networks composed of passive quantum nodes that interact with each other only with single photon pulses. Here we present an analytical and numerical study of deterministic single-photon Raman passage, and characterise its limitations and the parameters for optimal operation. Specifically, we study the effect of losses and the presence of multiple excited state...

  2. An on-chip coupled resonator optical waveguide single-photon buffer.

    Science.gov (United States)

    Takesue, Hiroki; Matsuda, Nobuyuki; Kuramochi, Eiichi; Munro, William J; Notomi, Masaya

    2013-01-01

    Integrated quantum optical circuits are now seen as one of the most promising approaches with which to realize single-photon quantum information processing. Many of the core elements for such circuits have been realized, including sources, gates and detectors. However, a significant missing function necessary for photonic quantum information processing on-chip is a buffer, where single photons are stored for a short period of time to facilitate circuit synchronization. Here we report an on-chip single-photon buffer based on coupled resonator optical waveguides (CROW) consisting of 400 high-Q photonic crystal line-defect nanocavities. By using the CROW, a pulsed single photon is successfully buffered for 150 ps with 50-ps tunability while maintaining its non-classical properties. Furthermore, we show that our buffer preserves entanglement by storing and retrieving one photon from a time-bin entangled state. This is a significant step towards an all-optical integrated quantum information processor.

  3. An on-chip coupled resonator optical waveguide single-photon buffer

    CERN Document Server

    Takesue, Hiroki; Kuramochi, Eiichi; Munro, Willian J; Notomi, Masaya

    2013-01-01

    Integrated quantum optical circuits are now seen as one of the most promising approaches with which to realize single photon quantum information processing. Many of the core elements for such circuits have been realized including sources, gates and detectors. However, a significant missing function necessary for photonic information processing on-chip is a buffer, where single photons are stored for a short period of time to facilitate circuit synchronization. Here we report an on-chip single photon buffer based on coupled resonator optical waveguides (CROW) consisting of 400 high-Q photonic crystal line defect nanocavities. By using the CROW, a pulsed single photon was successfully buffered for 150 ps with 50-ps tunability while maintaining its non-classical properties. Furthermore, we showed that our buffer preserves entanglement by storing and retrieving one photon from a time-bin entangled state. This is a significant step towards an all-optical integrated quantum information processor.

  4. NFAD Arrays for Single Photon Optical Communications at 1.5 um Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For this program, we propose to develop large pixel-count single photon counting detector arrays suitable for deployment in spacecraft terminal receivers supporting...

  5. Single Photon Sensitive HgCdTe Avalanche Photodiode Detector (APD) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging Phase I SBIR successes, in Phase II, a single photon sensitive LIDAR receiver will be fabricated and delivered to NASA. In Phase I, high-gain,...

  6. A gallium nitride single-photon source operating at 200 K.

    Science.gov (United States)

    Kako, Satoshi; Santori, Charles; Hoshino, Katsuyuki; Götzinger, Stephan; Yamamoto, Yoshihisa; Arakawa, Yasuhiko

    2006-11-01

    Fundamentally secure quantum cryptography has still not seen widespread application owing to the difficulty of generating single photons on demand. Semiconductor quantum-dot structures have recently shown great promise as practical single-photon sources, and devices with integrated optical cavities and electrical-carrier injection have already been demonstrated. However, a significant obstacle for the application of commonly used III-V quantum dots to quantum-information-processing schemes is the requirement of liquid-helium cryogenic temperatures. Epitaxially grown gallium nitride quantum dots embedded in aluminium nitride have the potential for operation at much higher temperatures. Here, we report triggered single-photon emission from gallium nitride quantum dots at temperatures up to 200 K, a temperature easily reachable with thermo-electric cooling. Gallium nitride quantum dots also open a new wavelength region in the blue and near-ultraviolet portions of the spectrum for single-photon sources.

  7. Wiring up pre-characterized single-photon emitters by laser lithography

    Science.gov (United States)

    Shi, Q.; Sontheimer, B.; Nikolay, N.; Schell, A. W.; Fischer, J.; Naber, A.; Benson, O.; Wegener, M.

    2016-08-01

    Future quantum optical chips will likely be hybrid in nature and include many single-photon emitters, waveguides, filters, as well as single-photon detectors. Here, we introduce a scalable optical localization-selection-lithography procedure for wiring up a large number of single-photon emitters via polymeric photonic wire bonds in three dimensions. First, we localize and characterize nitrogen vacancies in nanodiamonds inside a solid photoresist exhibiting low background fluorescence. Next, without intermediate steps and using the same optical instrument, we perform aligned three-dimensional laser lithography. As a proof of concept, we design, fabricate, and characterize three-dimensional functional waveguide elements on an optical chip. Each element consists of one single-photon emitter centered in a crossed-arc waveguide configuration, allowing for integrated optical excitation and efficient background suppression at the same time.

  8. A highly efficient single-photon source based on a quantum dot in a photonic nanowire

    DEFF Research Database (Denmark)

    Claudon, Julien; Bleuse, Joel; Malik, Nitin Singh

    2010-01-01

    The development of efficient solid-state sources of single photons is a major challenge in the context of quantum communication,optical quantum information processing and metrology1. Such a source must enable the implementation of a stable, single-photon emitter, like a colour centre in diamond2...... with carefully tailored ends13. Under optical pumping, we demonstrate a record source efficiency of 0.72, combined with pure single-photon emission. This non-resonant approach also provides broadband spontaneous emission control, thus offering appealing novel opportunities for the development of single-photon......–4 or a semiconductor quantum dot5–7. Achieving a high extraction efficiency has long been recognized as a major issue, and both classical solutions8 and cavity quantum electrodynamics effects have been applied1,9–12. We adopt a different approach, based on an InAs quantum dot embedded in a GaAs photonic nanowire...

  9. Bidirectional Mapping between a Biphoton Polarization State and a Single-Photon Two-Qubit State

    Institute of Scientific and Technical Information of China (English)

    LIN Qing

    2010-01-01

    @@ How to manipulate(operate or measure)single photons efficiently and simply is the basic problem in optical quantum information processing.We first present an efficient scheme to transform a biphoton polarization state to a corresponding single-photon state encoded by its polarization and spatial modes.This single-photon state carries both the information of the controlled and target photons.It will make the realization of bipartite positive-operator-valued measurements efficiently and simply.Moreover,the inverse transformation from the single-photon state back to the corresponding biphoton polarization state is also proposed.Using both the transformations,the realization of the arbitrary two-qubit unitary operation is simple with an M-Z interferometer.All the schemes are feasible with the current experimental technology.

  10. Central benzodiazepine receptor imaging and quantitation with single photon emission computerised tomography

    DEFF Research Database (Denmark)

    Okocha, C I; Kapczinski, F; Lassen, N

    1995-01-01

    This review discusses the current use of single photon emission computerised tomography (SPECT) for central benzodiazepine receptor imaging and quantitation. The general principles underlying SPECT imaging and receptor quantitation methods such as the kinetic, pseudo-equilibrium and steady...

  11. Experimental single photon exchange along a space link of 7000 km

    DEFF Research Database (Denmark)

    Dequal, Daniele; Vallone, Giuseppe; Bacco, Davide

    2015-01-01

    Extending the single photon transmission distance is a basic requirement for the implementation of quantum communication on a global scale. In this work we report the single photon exchange from a medium Earth orbit satellite (MEO) at more than 7000 km of slanted distance to the ground station...... at the Matera Laser Ranging Observatory. The single photon transmitter was realized by exploiting the corner cube retro-reflectors mounted on the LAGEOS-2 satellite. Long duration of data collection is possible with such altitude, up to 43 minutes in a single passage. The mean number of photons per pulse (µsat......) has been limited to 1 for 200 seconds, resulting in an average detection rate of 3.0 cps and a signal to noise ratio of 1.5. The feasibility of single photon exchange from MEO satellites paves the way to tests of Quantum Mechanics in moving frames and to global Quantum Information....

  12. Quantum Secret Sharing Protocol between Multiparty and Multiparty with Single Photons and Unitary Transformations

    Institute of Scientific and Technical Information of China (English)

    YAN Feng-Li; GAO Ting; LI You-Cheng

    2008-01-01

    @@ We propose a scheme of quantum secret sharing between Alice's group and Bob's group with single photons and unitary transformations. In the protocol, one member in Alice's group prepares a sequence of single photons in one of four different states, while other members directly encode their information on the sequence of single photons via unitary operations; after that, the last member sends the sequence of single photons to Bob's group.Then Bob's, except for the last one, do work similarly. Finally the last member in Bob's group measures the qubits. If the security of the quantum channel is guaranteed by some tests, then the qubit states sent by the last member of Alice's group can be used as key bits for secret sharing. It is shown that this scheme is safe.

  13. Controlled single-photon emission from a single trapped two-level atom.

    Science.gov (United States)

    Darquié, B; Jones, M P A; Dingjan, J; Beugnon, J; Bergamini, S; Sortais, Y; Messin, G; Browaeys, A; Grangier, P

    2005-07-15

    By illuminating an individual rubidium atom stored in a tight optical tweezer with short resonant light pulses, we created an efficient triggered source of single photons with a well-defined polarization. The measured intensity correlation of the emitted light pulses exhibits almost perfect antibunching. Such a source of high-rate, fully controlled single-photon pulses has many potential applications for quantum information processing.

  14. Quantum Frequency Conversion of Single-Photon States by Three and Four-Wave Mixing

    DEFF Research Database (Denmark)

    Raymer, Michael G.; Reddy, Dileep V.; Andersen, Lasse Mejling

    2013-01-01

    Three- or four-wave mixing can convert a single-photon wave packet to a new frequency. By tailoring the shapes of the pump(s), one can achieve add/drop functionality for different temporally orthogonal wave packets.......Three- or four-wave mixing can convert a single-photon wave packet to a new frequency. By tailoring the shapes of the pump(s), one can achieve add/drop functionality for different temporally orthogonal wave packets....

  15. Single photon quantum non-demolition in the presence of inhomogeneous broadening

    OpenAIRE

    Greentree, Andrew D.; Beausoleil, R. G.; Hollenberg, L. C. L.; Munro, W. J.; Nemoto, Kae; Prawer, S.; Spiller, T. P.

    2009-01-01

    Electromagnetically induced transparency (EIT) has been often proposed for generating nonlinear optical effects at the single photon level; in particular, as a means to effect a quantum non-demolition measurement of a single photon field. Previous treatments have usually considered homogeneously broadened samples, but realisations in any medium will have to contend with inhomogeneous broadening. Here we reappraise an earlier scheme [Munro \\textit{et al.} Phys. Rev. A \\textbf{71}, 033819 (2005...

  16. Derivation of the density matrix of a single photon produced in parametric down-conversion

    Science.gov (United States)

    Kolenderski, Piotr; Wasilewski, Wojciech

    2009-07-01

    We discuss an effective numerical method of density matrix determination of fiber coupled single photon generated in process of spontaneous parametric down conversion in type I noncollinear configuration. The presented theory has been successfully applied in case of source utilized to demonstrate the experimental characterization of spectral state of single photon, what was reported in Wasilewski, Kolenderski, and Frankowski [Phys. Rev. Lett. 99, 123601 (2007)].

  17. Modeling and Design of High-Efficiency Single-Photon Sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Per Kær; Mørk, Jesper

    2013-01-01

    Solid-state sources capable of emitting single photons on demand are of great interest in quantum information applications. Ideally, such a source should emit exactly one photon into the collection optics per trigger, the emitted photons should be indistinguishable, and the source should...... the light emission profile and the possibilities of tailoring it as well as the mechanisms governing the coherence are elucidated. The major design strategies pursued to optimize the single-photon source performance and the remaining challenges are reviewed....

  18. Temporal Purity and Quantum Interference of Single Photons from Two Independent Cold Atomic Ensembles

    Science.gov (United States)

    Qian, Peng; Gu, Zhenjie; Cao, Rong; Wen, Rong; Ou, Z. Y.; Chen, J. F.; Zhang, Weiping

    2016-07-01

    The temporal purity of single photons is crucial to the indistinguishability of independent photon sources for the fundamental study of the quantum nature of light and the development of photonic technologies. Currently, the technique for single photons heralded from time-frequency entangled biphotons created in nonlinear crystals does not guarantee the temporal-quantum purity, except using spectral filtering. Nevertheless, an entirely different situation is anticipated for narrow-band biphotons with a coherence time far longer than the time resolution of a single-photon detector. Here we demonstrate temporally pure single photons with a coherence time of 100 ns, directly heralded from the time-frequency entangled biphotons generated by spontaneous four-wave mixing in cold atomic ensembles, without any supplemented filters or cavities. A near-perfect purity and indistinguishability are both verified through Hong-Ou-Mandel quantum interference using single photons from two independent cold atomic ensembles. The time-frequency entanglement provides a route to manipulate the pure temporal state of the single-photon source.

  19. Efficient generation of indistinguishable single photons on-demand at telecom wavelengths

    Science.gov (United States)

    Kim, Jehyung; Cai, Tao; Richardson, Christopher; Leavitt, Richard; Waks, Edo

    Highly efficient single photon sources are important building blocks for optical quantum information processing. For practical use and long-distance quantum communication, single photons should have fiber-compatible telecom wavelengths. In addition, most quantum communication applications require high degree of indistinguishability of single photons, such that they exhibit interference on a beam splitter. However, deterministic generation of indistinguishable single photons with high brightness remains a challenging problem in particular at telecom wavelengths. We demonstrate a telecom wavelength source of indistinguishable single photons using an InAs/InP quantum dot in a nanophotonic cavity. To obtain the efficient single quantum dot emission, we employ the higher order mode in L3 photonic crystal cavity that shows a nearly Gaussian transverse mode profile and results in out-coupling efficiency exceeding 46 % and unusual bright single quantum dot emission exceeding 1.5 million counts per second at a detector. We also observe Purcell enhanced spontaneous emission rate as large as 4 and high linear polarization ratio of 0.96 for the coupled dots. Using this source, we generate high purity single photons at 1.3 μm wavelength and demonstrate the indistinguishable nature of the emission using a two-photon interference measurement.

  20. Numerical analysis of Ino.53Gao.47As/InP single photon avalanche diodes

    Institute of Scientific and Technical Information of China (English)

    Zhou Peng; Li Chun-Fei; Liao Chang-Jun; Wei Zheng-Jun; Yuan Shu-Qiong

    2011-01-01

    A rigorous theoretical model for In0.53Ga0.47As/InP single photon avalanche diode is utilized to investigate the dependences of single photon quantum efficiency and dark count probability on structure and operation condition. In the model, low field impact ionizations in charge and absorption layers are allowed, while avalanche breakdown can occur only in the multiplication layer. The origin of dark counts is discussed and the results indicate that the dominant mechanism that gives rise to dark counts depends on both device structure and operating condition. When the multiplication layer is thicker than a critical thickness or the temperature is higher than a critical value, generation-recombination in the absorption layer is the dominative mechanism; otherwise band-to-band tunneling in the multiplication layer dominates the dark counts. The thicknesses of charge and multiplication layers greatly affect the dark count and the peak single photon quantum efficiency and increasing the multiplication layer width may reduce the dark count probability and increase the peak single photon quantum efficiency. However, when the multiplication layer width exceeds 1 μm, the peak single photon quantum efficiency increases slowly and it is finally saturated at the quantum efficiency of the single photon avalanche diodes.

  1. Computational Modelling in Cancer: Methods and Applications

    Directory of Open Access Journals (Sweden)

    Konstantina Kourou

    2015-01-01

    Full Text Available Computational modelling of diseases is an emerging field, proven valuable for the diagnosis, prognosis and treatment of the disease. Cancer is one of the diseases where computational modelling provides enormous advancements, allowing the medical professionals to perform in silico experiments and gain insights prior to any in vivo procedure. In this paper, we review the most recent computational models that have been proposed for cancer. Well known databases used for computational modelling experiments, as well as, the various markup language representations are discussed. In addition, recent state of the art research studies related to tumour growth and angiogenesis modelling are presented.

  2. Progress Toward Single-Photon-Level Nonlinear Optics in Crystalline Microcavities

    Science.gov (United States)

    Kowligy, Abijith S.

    Over the last two decades, the emergence of quantum information science has uncovered many practical applications in areas such as communications, imaging, and sensing where harnessing quantum features of Nature provides tremendous benefits over existing methods exploiting classical physical phenomena. In this effort, one of the frontiers of research has been to identify and utilize quantum phenomena that are not susceptible to environmental and parasitic noise processes. Quantum photonics has been at the forefront of these studies because it allows room-temperature access to its inherently quantum-mechanical features, and allows leveraging the mature telecommunication industry. Accompanying the weak environmental influence, however, are also weak optical nonlinearities. Efficient nonlinear optical interactions are indispensible for many of the existing protocols for quantum optical computation and communication, e.g. high-fidelity entangling quantum logic gates rely on large nonlinear responses at the one- or few-photon-level. While this has been addressed to a great extent by interfacing photons with single quantum emitters and cold atomic gases, scalability has remained elusive. In this work, we identify the macroscopic second-order nonlinear polarization as a robust platform to address this challenge, and utilize the recent advances in the burgeoning field of optical microcavities to enhance this nonlinear response. In particular, we show theoretically that by using the quantum Zeno effect, low-noise, single-photon-level optical nonlinearities can be realized in lithium niobate whispering-gallery-mode microcavities, and present experimental progress toward this goal. Using the measured strength of the second-order nonlinear response in lithium niobate, we modeled the nonlinear system in the strong coupling regime using the Schrodinger picture framework and theoretically demonstrated that the single-photon-level operation can be observed for cavity lifetimes in

  3. An ultra-fast thermoelectric sensor for single-photon detection in a wide range of the electromagnetic spectrum

    Science.gov (United States)

    Kuzanyan, Astghik A.; Nikoghosyan, Vahan R.; Kuzanyan, Armen S.

    2017-05-01

    The results of computer simulation of heat distribution processes taking place after the absorption of single photons of 1-1000 eV energy in the three-layer detection pixel of the thermoelectric detector are presented. We considered different geometries of the detection pixel in which (La,Ce)B6 hexaboride is used as a thermoelectric layer and superconducting absorber and heat sink layers are of Nb, Pb and YBCO. The calculations are based on the heat conduction equation and are carried out by the matrix method for differential equations. It is shown, that by changing materials and sizes of the detection pixel's layers it is possible to obtain transducers for the registration of photons within the given spectral range with the required energy resolution and count rate. It is demonstrated that such detector has a number of advantages, as well as improved characteristics, which give ground to consider the thermoelectric detector as a real alternative to superconducting nanowire single-photon detectors.

  4. Linear optical quantum metrology with single photons: exploiting spontaneously generated entanglement to beat the shot-noise limit.

    Science.gov (United States)

    Motes, Keith R; Olson, Jonathan P; Rabeaux, Evan J; Dowling, Jonathan P; Olson, S Jay; Rohde, Peter P

    2015-05-01

    Quantum number-path entanglement is a resource for supersensitive quantum metrology and in particular provides for sub-shot-noise or even Heisenberg-limited sensitivity. However, such number-path entanglement has been thought to be resource intensive to create in the first place--typically requiring either very strong nonlinearities, or nondeterministic preparation schemes with feedforward, which are difficult to implement. Very recently, arising from the study of quantum random walks with multiphoton walkers, as well as the study of the computational complexity of passive linear optical interferometers fed with single-photon inputs, it has been shown that such passive linear optical devices generate a superexponentially large amount of number-path entanglement. A logical question to ask is whether this entanglement may be exploited for quantum metrology. We answer that question here in the affirmative by showing that a simple, passive, linear-optical interferometer--fed with only uncorrelated, single-photon inputs, coupled with simple, single-mode, disjoint photodetection--is capable of significantly beating the shot-noise limit. Our result implies a pathway forward to practical quantum metrology with readily available technology.

  5. Quantum interference between two single photons emitted by independently trapped atoms.

    Science.gov (United States)

    Beugnon, J; Jones, M P A; Dingjan, J; Darquié, B; Messin, G; Browaeys, A; Grangier, P

    2006-04-06

    When two indistinguishable single photons are fed into the two input ports of a beam splitter, the photons will coalesce and leave together from the same output port. This is a quantum interference effect, which occurs because two possible paths-in which the photons leave by different output ports-interfere destructively. This effect was first observed in parametric downconversion (in which a nonlinear crystal splits a single photon into two photons of lower energy), then from two separate downconversion crystals, as well as with single photons produced one after the other by the same quantum emitter. With the recent developments in quantum information research, much attention has been devoted to this interference effect as a resource for quantum data processing using linear optics techniques. To ensure the scalability of schemes based on these ideas, it is crucial that indistinguishable photons are emitted by a collection of synchronized, but otherwise independent sources. Here we demonstrate the quantum interference of two single photons emitted by two independently trapped single atoms, bridging the gap towards the simultaneous emission of many indistinguishable single photons by different emitters. Our data analysis shows that the observed coalescence is mainly limited by wavefront matching of the light emitted by the two atoms, and to a lesser extent by the motion of each atom in its own trap.

  6. Single-Photon Avalanche Diodes (SPAD) in CMOS 0.35 μm technology

    Science.gov (United States)

    Pellion, D.; Jradi, K.; Brochard, N.; Prêle, D.; Ginhac, D.

    2015-07-01

    Some decades ago single photon detection used to be the terrain of photomultiplier tube (PMT), thanks to its characteristics of sensitivity and speed. However, PMT has several disadvantages such as low quantum efficiency, overall dimensions, and cost, making them unsuitable for compact design of integrated systems. So, the past decade has seen a dramatic increase in interest in new integrated single-photon detectors called Single-Photon Avalanche Diodes (SPAD) or Geiger-mode APD. SPAD are working in avalanche mode above the breakdown level. When an incident photon is captured, a very fast avalanche is triggered, generating an easily detectable current pulse. This paper discusses SPAD detectors fabricated in a standard CMOS technology featuring both single-photon sensitivity, and excellent timing resolution, while guaranteeing a high integration. In this work, we investigate the design of SPAD detectors using the AMS 0.35 μm CMOS Opto technology. Indeed, such standard CMOS technology allows producing large surface (few mm2) of single photon sensitive detectors. Moreover, SPAD in CMOS technologies could be associated to electronic readout such as active quenching, digital to analog converter, memories and any specific processing required to build efficient calorimeters1

  7. Nonlocality of a single photon: paths to an EPR-steering experiment

    CERN Document Server

    Jones, S J

    2011-01-01

    A single photon incident on a beam splitter produces an entangled field state, and in principle could be used to violate a Bell-inequality, but such an experiment (without post-selection) is beyond the reach of current experiments. Here we consider the somewhat simpler task of demonstrating EPR-steering with a single photon (also without post-selection). That is, of demonstrating that Alice's choice of measurement on her "half" of a single photon can affect the other "half" of the photon in Bob's lab, in a sense rigorously defined by us and Doherty [Phys. Rev. Lett. 98, 140402 (2007)]. Previous work by Lvovsky and co-workers [Phys. Rev. Lett. 92, 047903 (2004)] has addressed this phenomenon (which they called "remote preparation") experimentally using homodyne measurements on a single photon. Here we show that, unfortunately, their experimental parameters do not meet the bounds necessary for a rigorous demonstration of EPR-steering with a single photon. However, we also show that modest improvements in the ex...

  8. Single photon detection in a waveguide-coupled Ge-on-Si lateral avalanche photodiode.

    Science.gov (United States)

    Martinez, Nicholas J D; Gehl, Michael; Derose, Christopher T; Starbuck, Andrew L; Pomerene, Andrew T; Lentine, Anthony L; Trotter, Douglas C; Davids, Paul S

    2017-07-10

    We examine gated-Geiger mode operation of an integrated waveguide-coupled Ge-on-Si lateral avalanche photodiode (APD) and demonstrate single photon detection at low dark count for this mode of operation. Our integrated waveguide-coupled APD is fabricated using a selective epitaxial Ge-on-Si growth process resulting in a separate absorption and charge multiplication (SACM) design compatible with our silicon photonics platform. Single photon detection efficiency and dark count rate is measured as a function of temperature in order to understand and optimize performance characteristics in this device. We report single photon detection of 5.27% at 1310 nm and a dark count rate of 534 kHz at 80 K for a Ge-on-Si single photon avalanche diode. Dark count rate is the lowest for a Ge-on-Si single photon detector in this range of temperatures while maintaining competitive detection efficiency. A jitter of 105 ps was measured for this device.

  9. Room-temperature single-photon generation from solitary dopants of carbon nanotubes

    Science.gov (United States)

    Ma, Xuedan; Hartmann, Nicolai F.; Baldwin, Jon K. S.; Doorn, Stephen K.; Htoon, Han

    2015-08-01

    On-demand single-photon sources capable of operating at room temperature and the telecom wavelength range of 1,300-1,500 nm hold the key to the realization of novel technologies that span from sub-diffraction imaging to quantum key distribution and photonic quantum information processing. Here, we show that incorporation of undoped (6,5) single-walled carbon nanotubes into a SiO2 matrix can lead to the creation of solitary oxygen dopant states capable of fluctuation-free, room-temperature single-photon emission in the 1,100-1,300 nm wavelength range. We investigated the effects of temperature on photoluminescence emission efficiencies, fluctuations and decay dynamics of the dopant states and determined the conditions most suitable for the observation of single-photon emission. This emission can in principle be extended to 1,500 nm by doping of smaller-bandgap single-walled carbon nanotubes. This easy tunability presents a distinct advantage over existing defect centre single-photon emitters (for example, diamond defect centres). Our SiO2-encapsulated sample also presents exciting opportunities to apply Si/SiO2-based micro/nano-device fabrication techniques in the development of electrically driven single-photon sources and integration of these sources into quantum photonic devices and networks.

  10. Wigner spectrum and coherent feedback control of continuous-mode single-photon Fock states

    Science.gov (United States)

    Dong, Zhiyuan; Cui, Lei; Zhang, Guofeng; Fu, Hongchen

    2016-10-01

    Single photons are very useful resources in quantum information science. In real applications it is often required that the photons have a well-defined spectral (or equivalently temporal) modal structure. For example, a rising exponential pulse is able to fully excite a two-level atom while a Gaussian pulse cannot. This motivates the study of continuous-mode single-photon Fock states. Such states are characterized by a spectral (or temporal) pulse shape. In this paper we investigate the statistical property of continuous-mode single-photon Fock states. Instead of the commonly used normal ordering (Wick order), the tool we proposed is the Wigner spectrum. The Wigner spectrum has two advantages: (1) it allows to study continuous-mode single-photon Fock states in the time domain and frequency domain simultaneously; (2) because it can deal with the Dirac delta function directly, it has the potential to provide more information than the normal ordering where the Dirac delta function is always discarded. We also show how various control methods in particular coherent feedback control can be used to manipulate the pulse shapes of continuous-mode single-photon Fock states.

  11. Room temperature single photon source using fiber-integrated hexagonal boron nitride

    Science.gov (United States)

    Vogl, Tobias; Lu, Yuerui; Lam, Ping Koy

    2017-07-01

    Single photons are a key resource for quantum optics and optical quantum information processing. The integration of scalable room temperature quantum emitters into photonic circuits remains to be a technical challenge. Here we utilize a defect center in hexagonal boron nitride (hBN) attached by Van der Waals force onto a multimode fiber as a single photon source. We perform an optical characterization of the source in terms of spectrum, state lifetime, power saturation and photostability. A special feature of our source is that it allows for easy switching between fiber-coupled and free space single photon generation modes. In order to prove the quantum nature of the emission we measure the second-order correlation function {{g}(2)}≤ft(τ \\right) . For both fiber-coupled and free space emission, the {{g}(2)}≤ft(τ \\right) dips below 0.5 indicating operation in the single photon regime. The results so far demonstrate the feasibility of 2D material single photon sources for scalable photonic quantum information processing.

  12. Practical single-photon-assisted remote state preparation with non-maximally entanglement

    Science.gov (United States)

    Wang, Dong; Huang, Ai-Jun; Sun, Wen-Yang; Shi, Jia-Dong; Ye, Liu

    2016-08-01

    Remote state preparation (RSP) and joint remote state preparation (JRSP) protocols for single-photon states are investigated via linear optical elements with partially entangled states. In our scheme, by choosing two-mode instances from a polarizing beam splitter, only the sender in the communication protocol needs to prepare an ancillary single-photon and operate the entanglement preparation process in order to retrieve an arbitrary single-photon state from a photon pair in partially entangled state. In the case of JRSP, i.e., a canonical model of RSP with multi-party, we consider that the information of the desired state is split into many subsets and in prior maintained by spatially separate parties. Specifically, with the assistance of a single-photon state and a three-photon entangled state, it turns out that an arbitrary single-photon state can be jointly and remotely prepared with certain probability, which is characterized by the coefficients of both the employed entangled state and the target state. Remarkably, our protocol is readily to extend to the case for RSP and JRSP of mixed states with the all optical means. Therefore, our protocol is promising for communicating among optics-based multi-node quantum networks.

  13. Testing nonlocality of a single photon without a shared reference frame

    Science.gov (United States)

    Brask, Jonatan Bohr; Chaves, Rafael; Brunner, Nicolas

    2013-07-01

    The question of testing the nonlocality of a single photon has raised much debate over the last years. The controversy is intimately related to the issue of providing a common reference frame for the observers to perform their local measurements. Here we address this point by presenting a simple scheme for demonstrating the nonlocality of a single photon which does not require a shared reference frame. Specifically, Bell inequality violation can be obtained with certainty with unaligned devices, even if the relative frame fluctuates between each experimental run of the Bell test. Our scheme appears feasible with current technology and may simplify the realization of quantum communication protocols based on single-photon entanglement.

  14. A universal setup for active control of a single-photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Qin; Skaar, Johannes [Department of Electronics and Telecommunications, Norwegian University of Science and Technology, NO-7491 Trondheim (Norway); Lamas-Linares, Antía; Kurtsiefer, Christian [Centre for Quantum Technologies and Department of Physics, National University of Singapore, 3 Science Drive 2, Singapore 117543 (Singapore); Makarov, Vadim, E-mail: makarov@vad1.com [Institute for Quantum Computing and Department of Physics and Astronomy, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Gerhardt, Ilja, E-mail: ilja@quantumlah.org [Max Planck Institute for Solid State Research, Heisenbergstraße 1, D-70569 Stuttgart (Germany)

    2014-01-15

    The influence of bright light on a single-photon detector has been described in a number of recent publications. The impact on quantum key distribution (QKD) is important, and several hacking experiments have been tailored to fully control single-photon detectors. Special attention has been given to avoid introducing further errors into a QKD system. We describe the design and technical details of an apparatus which allows to attack a quantum-cryptographic connection. This device is capable of controlling free-space and fiber-based systems and of minimizing unwanted clicks in the system. With different control diagrams, we are able to achieve a different level of control. The control was initially targeted to the systems using BB84 protocol, with polarization encoding and basis switching using beamsplitters, but could be extended to other types of systems. We further outline how to characterize the quality of active control of single-photon detectors.

  15. Quantum interference between two single photons emitted by independently trapped atoms

    CERN Document Server

    Beugnon, J; Dingjan, J; Darquié, B; Messin, G; Browaeys, A; Grangier, P; Beugnon, Jerome; Jones, Matthew; Dingjan, Jos; Darqui\\'{e}, Benoit; Messin, Gaetan; Browaeys, Antoine; Grangier, Philippe

    2006-01-01

    When two indistinguishable single photons are fed into the two input ports of a beam splitter, the photons will coalesce and leave together from the same output port. This is a quantum interference effect, which occurs because the two possible paths where the photons leave in different output ports interfere destructively. This effect was first observed in parametric downconversion by Hong, Ou and Mandel, and then with single photons produced one after the other by the same quantum emitter. With the recent development of quantum information, a lot of attention has been devoted to this coalescence effect as a resource for quantum data processing using linear optics techniques. To ensure the scalability of schemes based on these ideas, it is crucial that indistinguishable photons are emitted by a collection of synchronized, but otherwise independent sources. In this paper, we demonstrate the quantum interference of two single photons emitted by two independently trapped single atoms, bridging the gap towards th...

  16. Controlling the quantum state of a single photon emitted from a single polariton

    Energy Technology Data Exchange (ETDEWEB)

    Stanojevic, Jovica; Parigi, Valentina; Bimbard, Erwan; Tualle-Brouri, Rosa; Ourjoumtsev, Alexei; Grangier, Philippe [Laboratoire Charles Fabry, Institut d' Optique, CNRS, Universite Paris-Sud, Campus Polytechnique, RD 128, FR-91127 Palaiseau cedex (France)

    2011-11-15

    We investigate in detail the optimal conditions for a high fidelity transfer from a single-polariton state to a single-photon state and subsequent homodyne detection of the single photon. We assume that, using various possible techniques, the single polariton has initially been stored as a spin-wave grating in a cloud of cold atoms inside a low-finesse cavity. This state is then transferred to a single-photon optical pulse using an auxiliary beam. We optimize the retrieval efficiency and determine the mode of the local oscillator that maximizes the homodyne efficiency of such a photon. We find that both efficiencies can have values close to one in a large region of experimental parameters.

  17. Controlling the quantum state of a single photon emitted from a single polariton

    CERN Document Server

    Stanojevic, Jovica; Bimbard, Erwan; Tualle-Brouri, Rosa; Ourjoumtsev, Alexei; Grangier, Philippe; 10.1103/PhysRevA.84.053830

    2012-01-01

    We investigate in detail the optimal conditions for a high fidelity transfer from a single-polariton state to a single-photon state and subsequent homodyne detection of the single photon. We assume that, using various possible techniques, the single polariton has initially been stored as a spin-wave grating in a cloud of cold atoms inside a low-finesse cavity. This state is then transferred to a single-photon optical pulse using an auxiliary beam. We optimize the retrieval efficiency and determine the mode of the local oscillator that maximizes the homodyne efficiency of such a photon. We find that both efficiencies can have values close to one in a large region of experimental parameters.

  18. All-fibre multiplexed source of high-purity heralded single photons

    CERN Document Server

    Francis-Jones, Robert J A; Mosley, Peter J

    2016-01-01

    Single photon sources based on spontaneous photon-pair generation have enabled pioneering experiments in quantum optics. However, their non-determinism presents a bottleneck to scaling up photonic and hybrid quantum-enhanced technologies. Furthermore, photon pairs are typically emitted into many correlated frequency modes, producing an undesirable mixed state on heralding. Here we present a complete fibre-integrated heralded single photon source that addresses both these difficulties simultaneously. We use active switching to provide a path to deterministic operation by multiplexing separate spontaneous sources, and dispersion engineering to minimise frequency correlation for high-purity single photon generation. All the essential elements -- nonlinear material with dispersion control, wavelength isolation, optical delay, and fast switching -- are incorporated in a low-loss alignment-free package that heralds photons in telecoms single-mode fibre. Our results demonstrate a scalable approach to delivering pure...

  19. Single-photon transport through a waveguide coupling to a quadratic optomechanical system

    Science.gov (United States)

    Qiao, Lei

    2017-07-01

    We study the coherent transport of a single photon, which propagates in a one-dimensional waveguide and is scattered by a quadratic optomechanical system. Our approach, which is based on the Lippmann-Schwinger equation, gives an analytical solution to describe the single-photon transmission and reflection properties. We analyze the transport spectra and find they are not only related to the optomechanical system's energy-level structure, but also dependent on the optomechanical system's inherent parameters. For the existence of atomic degrees of freedom, we get a Rabi-splitting-like or an electromagnetically induced transparency (EIT)-like spectrum, depending on the atom-cavity coupling strength. Here, we focus on the single-photon strong-coupling regime so that single-quantum effects could be seen.

  20. Fluctuation mechanisms in superconductors nanowire single-photon counters, enabled by effective top-down manufacturing

    CERN Document Server

    Bartolf, Holger

    2016-01-01

    Holger Bartolf discusses state-of-the-art detection concepts based on superconducting nanotechnology as well as sophisticated analytical formulæ that model dissipative fluctuation-phenomena in superconducting nanowire single-photon detectors. Such knowledge is desirable for the development of advanced devices which are designed to possess an intrinsic robustness against vortex-fluctuations and it provides the perspective for honorable fundamental science in condensed matter physics. Especially the nanowire detector allows for ultra-low noise detection of signals with single-photon sensitivity and GHz repetition rates. Such devices have a huge potential for future technological impact and might enable unique applications (e.g. high rate interplanetary deep-space data links from Mars to Earth). Contents Superconducting Single-Photon Detectors Nanotechnological Manufacturing; Scale: 10 Nanometer Berezinskii-Kosterlitz Thouless (BKT) Transition, Edge-Barrier, Phase Slips Target Groups Researchers and students of...