WorldWideScience

Sample records for calorimeter technical design

  1. CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter

    CERN Document Server

    Mans, J; Dahmes, B; de Barbaro, P; Freeman, J; Grassi, T; Hazen, E; Mans, J; Ruchti, R; Schimdt, I; Shaw, T; Tully, C; Whitmore, J; Yetkin, T

    2012-01-01

    This report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation of the calorimeter and providing new capabilities for anomalous background rejection. The photodetectors of the CMS Barrel and Endcap Hadron Calorimeters, currently hybrid photodiodes (HPDs), will be replaced by silicon photomultiplier (SiPM) devices. The single-channel phototubes of the Forward Hadron Calorimeter will be replaced by multi-anode phototubes operated in a dual-anode configuration. The readout electronics for all three calorimeter systems will also be replaced. A new charge-integrating ADC, the QIE10, with an integrated TDC will be used along with a 4.8 Gbps data-link. The off-detector electronics will also be substantially upgraded to handle higher data volumes and improve the information sent to the ...

  2. TECHNICAL DESIGN REPORT FOR A NOSECONE CALORIMETER (NCC) FOR THE PHENIX EXPERIMENT.

    Energy Technology Data Exchange (ETDEWEB)

    PHENIX EXPERIMENT; OBRIEN,E.; BOOSE, S.; CHIU, M.; JOHNSON, B.M.; KISTENEV, E.P.; LYNCH, D.; NOUICER, R.; PAK, R.; PISANI, R.; STOLL, S.P.; SUKHANOV, A.; WOODY, C.L.; LI, Z.; RADEKA, V.; RESCIA, S.; (PHENIX EXPERIMENT COLLABORATORS)

    2007-08-01

    A remarkable result has emerged from the first several years of data taking at RHIC--the high temperature and density phase of QCD matter created in heavy ion collisions at RHIC is best described as a near perfect fluid--the strongly interacting Quark-Gluon-Plasma (sQGP). This state is characterized by a small viscosity to entropy ratio, and a high density of color charges which induces huge energy losses of partons transversing the medium. The task for the future is to understand the characteristics of the sQGP, and perhaps more importantly--to gain some insight into how and why such a medium is created. The PHENIX detector has been one of the primary experimental tools at RHIC; in particular the electromagnetic calorimeter has been a critical component of many of the measurements leading to this discovery. The coverage of the present PHENIX electromagnetic calorimeter is rather limited, covering half the azimuth and -0.35< {eta} <0.35 Further progress requires larger coverage of electromagnetic calorimetry, both to increase the rate for low cross section phenomena, and to cover a broader range of pseudorapidity to study the rapidity dependence of the medium. A pair of Nosecone Calorimeters (NCC) has been designed covering both positive and negative rapidity regions 1< |{eta}| <3 of the PHENIX detector. The NCC will make it possible to perform tomographic studies of the jet energy dependence of energy loss and medium response, by using direct photons as trigger particles over a large rapidity range. The technique of correlating trigger hadrons with low momentum hadrons has been powerfully exploited at RHIC to study the evolution of back to back jets [1, 2] and hence the response of the medium. The NCC will make it possible to do such studies using direct photons as the trigger particles. The direct photon in such ''photon-jet'' events tags the transverse momentum of outgoing parton which then fragments into lower energy particles. Together with

  3. Design and development of the SDC barrel electromagnetic calorimeter

    International Nuclear Information System (INIS)

    In fulfillment of contract SSC92-W-17743, Argonne National Laboratory is required to closeout and document all work performed in the design and development of the central calorimeter for the Solenoidal Detector Collaboration (SDC) Detector at the Superconducting Super Collider Laboratory (SSCL). This report will summarize the work performed, and identify all documents (technical reports, memo's, drawings, etc.) that resulted from that effort. The work under this contract was shared in collaboration with the Westinghouse Science and Technology Center (WSTC) of Pittsburgh, Pennsylvania. It is the intent of this report to provide information that can be useful in the development of future detectors for high energy physics particle research

  4. Design, Construction and Commissioning of the Digital Hadron Calorimeter - DHCAL

    CERN Document Server

    Adams, C; Bilki, B; Butler, J; Corriveau, F; Cundiff, T; Drake, G; Francis, K; Furst, B; Guarino, V; Haberichter, B; Hazen, E; Hoff, J; Holm, S; Kreps, A; DeLurgio, P; Matijas, Z; Monte, L Dal; Mucia, N; Norbeck, E; Northacker, D; Onel, Y; Pollack, B; Repond, J; Schlereth, J; Skrzecz, F; Smith, J R; Trojand, D; Underwood, D; Velasco, M; Walendziak, J; Wood, K; Wu, S; Xia, L; Zhang, Q; Zhao, A

    2016-01-01

    A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of this prototype calorimeter.

  5. Design of Refractory Metal Life Test Heat Pipe and Calorimeter

    Science.gov (United States)

    Martin, J. J.; Reid, R. S.; Bragg-Sitton, S. M.

    2010-01-01

    Heat pipe life tests have seldom been conducted on a systematic basis. Typically, one or more heat pipes are built and tested for an extended period at a single temperature with simple condenser loading. Results are often reported describing the wall material, working fluid, test temperature, test duration, and occasionally the nature of any failure. Important information such as design details, processing procedures, material assay, power throughput, and radial power density are usually not mentioned. We propose to develop methods to generate carefully controlled data that conclusively establish heat pipe operating life with material-fluid combinations capable of extended operation. The test approach detailed in this Technical Publication will use 16 Mo-44.5%Re alloy/sodium heat pipe units that have an approximate12-in length and 5/8-in diameter. Two specific test series have been identified: (1) Long-term corrosion rates based on ASTM-G-68-80 (G-series) and (2) corrosion trends in a cross-correlation sequence at various temperatures and mass fluences based on a Fisher multifactor design (F-series). Evaluation of the heat pipe hardware will be performed in test chambers purged with an inert purified gas (helium or helium/argon mixture) at low pressure (10-100 torr) to provide thermal coupling between the heat pipe condenser and calorimeter. The final pressure will be selected to minimize the potential for voltage breakdown between the heat pipe and radio frequency (RF) induction coil (RF heating is currently the planned method of powering the heat pipes). The proposed calorimeter is constructed from a copper alloy and relies on a laminar flow water-coolant channel design to absorb and transport energy

  6. Design and Prototyping of a High Granularity Scintillator Calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Zutshi, Vishnu [Northern Illinois Univ., DeKalb, IL (United States). Dept. of Physics

    2016-03-27

    A novel approach for constructing fine-granularity scintillator calorimeters, based on the concept of an Integrated Readout Layer (IRL) was developed. The IRL consists of a printed circuit board inside the detector which supports the directly-coupled scintillator tiles, connects to the surface-mount SiPMs and carries the necessary front-end electronics and signal/bias traces. Prototype IRLs using this concept were designed, prototyped and successfully exposed to test beams. Concepts and implementations of an IRL carried out with funds associated with this contract promise to result in the next generation of scintillator calorimeters.

  7. ANL small-sample calorimeter system design and operation

    Energy Technology Data Exchange (ETDEWEB)

    Roche, C.T.; Perry, R.B.; Lewis, R.N.; Jung, E.A.; Haumann, J.R.

    1978-07-01

    The Small-Sample Calorimetric System is a portable instrument designed to measure the thermal power produced by radioactive decay of plutonium-containing fuels. The small-sample calorimeter is capable of measuring samples producing power up to 32 milliwatts at a rate of one sample every 20 min. The instrument is contained in two packages: a data-acquisition module consisting of a microprocessor with an 8K-byte nonvolatile memory, and a measurement module consisting of the calorimeter and a sample preheater. The total weight of the system is 18 kg.

  8. Design, performance, and upgrade of the D0 calorimeter

    International Nuclear Information System (INIS)

    The D0 detector, located at the Fermi National Accelerator Laboratory in Batavia, Illinois, USA, is a large hermetic detector designed for the study of proton-antiproton collisions at a center-of-mass energy of 2 TeV. The calorimeter is a sampling device that employs uranium absorber and liquid argon as the active material. It has been designed for the high-precision energy measurement of electrons and jets over the full solid angle, and excellent missing transverse energy resolution for enhanced neutrino open-quotes detectionclose quotes. The authors report on some fundamental aspects of the D0 calorimeter's design and performance (the latter having been measured in both test beams and during recent data taking at the Fermilab collider), and their plan for the upgrade, which has been designed to accomodate the higher luminosities anticipated after completion of the Fermilab Main Injector

  9. Design of a microwave calorimeter for the microwave tokamak experiment

    Energy Technology Data Exchange (ETDEWEB)

    Marinak, M. (California Univ., Berkeley, CA (USA))

    1988-10-07

    The initial design of a microwave calorimeter for the Microwave Tokamak Experiment is presented. The design is optimized to measure the refraction and absorption of millimeter rf microwaves as they traverse the toroidal plasma of the Alcator C tokamak. Techniques utilized can be adapted for use in measuring high intensity pulsed output from a microwave device in an environment of ultra high vacuum, intense fields of ionizing and non-ionizing radiation and intense magnetic fields. 16 refs.

  10. Design of a microwave calorimeter for the microwave tokamak experiment

    International Nuclear Information System (INIS)

    The initial design of a microwave calorimeter for the Microwave Tokamak Experiment is presented. The design is optimized to measure the refraction and absorption of millimeter rf microwaves as they traverse the toroidal plasma of the Alcator C tokamak. Techniques utilized can be adapted for use in measuring high intensity pulsed output from a microwave device in an environment of ultra high vacuum, intense fields of ionizing and non-ionizing radiation and intense magnetic fields. 16 refs

  11. Design and performance of the SAPHIR lead-glass calorimeter

    International Nuclear Information System (INIS)

    For the WA80 fixed-target heavy-ion experiment at the CERN-SPS, a 1278 element lead-glass calorimeter has been constructed to measure photons in the energy range from 0.2 to 20 GeV. We describe the design of the detector, the achieved energy and position resolution, the gain monitoring system and the performance of the high-energy photon trigger. The quality of photon identification and π0 invariant mass reconstruction is discussed. (orig.)

  12. Conceptual design and performance simulations of super-compact electromagnetic calorimeter

    Directory of Open Access Journals (Sweden)

    Skoda Libor

    2013-11-01

    Full Text Available Measurements of particle production at forward rapidities in high energy p-p, p-A and A-A collisions provide access to physics processes at very low Bjorken x. These measurements will allow to study the gluon saturation scale and improve our knowledge of parton distribution in nuclei. Specific requirements must be fulfilled for a calorimeter to successfully operate in high-multiplicity forward region within often stringent space limits. Here we present a study of a conceptual design of super-compact electromagnetic calorimeter being developed at Czech Technical University in Prague. The design of the sampling calorimeter is based on a sandwich structure of thin tungsten and scintillator layers oriented in parallel to the beam. Used optical readout of individual scintillator pads guaranties the required high radiation hardness of the detector. We present simulation of the expected performance of the optical pad readout together with overall detector performance. It is aimed for the detector to allow measuring of high energy photons (1

  13. Design and performance of the SAPHIR lead-glass calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Baumeister, H.; Beckmann, P.; Berger, F.; Brummund, N.; Clewing, G.; Dragon, L.; Glasow, R.; Grzonka, D.; Hassenmeier, W.; Kampert, K.H.; Loehner, H.; Peitzmann, T.; Purschke, M.; Santo, R.; Verhoeven, W.; Wienke, R. (Muenster Univ. (Germany, F.R.). Inst. fuer Kernphysik); CERN-SPS WA80 Collaboration

    1990-06-15

    For the WA80 fixed-target heavy-ion experiment at the CERN-SPS, a 1278 element lead-glass calorimeter has been constructed to measure photons in the energy range from 0.2 to 20 GeV. We describe the design of the detector, the achieved energy and position resolution, the gain monitoring system and the performance of the high-energy photon trigger. The quality of photon identification and {pi}{sup 0} invariant mass reconstruction is discussed. (orig.).

  14. Design, Construction and Testing of the Digital Hadron Calorimeter (DHCAL) Electronics

    CERN Document Server

    Adams, C; Bilki, B; Butler, J; Corriveau, F; Cundiff, T; Drake, G; Francis, K; Guarino, V; Haberichter, B; Hazen, E; Hoff, J; Holm, S; Kreps, A; DeLurgio, P; Monte, L Dal; Mucia, N; Norbeck, E; Northacker, D; Onel, Y; Pollack, B; Repond, J; Schlereth, J; Smith, J R; Trojand, D; Underwood, D; Velasco, M; Walendziak, J; Wood, K; Wu, S; Xia, L; Zhang, Q; Zhao, A

    2016-01-01

    A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely segmented readout with 1 x 1 cm2 cells. The active media of the calorimeter are Resistive Plate Chambers (RPCs) with a digital, i.e. one-bit, readout. To first order the energy of incident particles in this calorimeter is reconstructed as being proportional to the number of pads with a signal over a given threshold. A large-scale prototype calorimeter with approximately 500,000 readout channels has been built and underwent extensive testing in the Fermilab and CERN test beams. This paper reports on the design, construction, and commissioning of the electronic readout system of this prototype calorimeter. The system is based on the DCAL front-end chip and a VME-based back-end.

  15. Design studies and sensor tests for the beam calorimeter of the ILC detector

    International Nuclear Information System (INIS)

    The International Linear Collider (ILC) is being designed to explore particle physics at the TeV scale. The design of the Very Forward Region of the ILC detector is considered in the presented work. The Beam Calorimeter - one of two electromagnetic calorimeters situated there - is the subject of this thesis. The Beam Calorimeter has to provide a good hermeticity for high energy electrons, positrons and photons down to very low polar angles, serve for fast beam diagnostics and shield the inner part of the detector from backscattered beamstrahlung remnants and synchrotron radiation. As a possible technology for the Beam Calorimeter a diamond-tungsten sandwich calorimeter is considered. Detailed simulation studies are done in order to explore the suitability of the considered design for the Beam Calorimeter objectives. Detection efficiency, energy and angular resolution for electromagnetic showers are studied. At the simulation level the diamondtungsten design is shown to match the requirements on the Beam Calorimeter performance. Studies of polycrystalline chemical vapour deposition (pCVD) diamond as a sensor material for the Beam Calorimeter are done to explore the properties of the material. Results of the measurements performed with pCVD diamond samples produced by different manufacturers are presented. (orig.)

  16. Design studies and sensor tests for the beam calorimeter of the ILC detector

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsova, E.

    2007-03-15

    The International Linear Collider (ILC) is being designed to explore particle physics at the TeV scale. The design of the Very Forward Region of the ILC detector is considered in the presented work. The Beam Calorimeter - one of two electromagnetic calorimeters situated there - is the subject of this thesis. The Beam Calorimeter has to provide a good hermeticity for high energy electrons, positrons and photons down to very low polar angles, serve for fast beam diagnostics and shield the inner part of the detector from backscattered beamstrahlung remnants and synchrotron radiation. As a possible technology for the Beam Calorimeter a diamond-tungsten sandwich calorimeter is considered. Detailed simulation studies are done in order to explore the suitability of the considered design for the Beam Calorimeter objectives. Detection efficiency, energy and angular resolution for electromagnetic showers are studied. At the simulation level the diamondtungsten design is shown to match the requirements on the Beam Calorimeter performance. Studies of polycrystalline chemical vapour deposition (pCVD) diamond as a sensor material for the Beam Calorimeter are done to explore the properties of the material. Results of the measurements performed with pCVD diamond samples produced by different manufacturers are presented. (orig.)

  17. CMS Forward Calorimeters Phase II Upgrade

    CERN Document Server

    Bilki, Burak

    2014-01-01

    The Phase II Upgrade of the CMS forward calorimeters (electromagnetic and hadronic) originates from the fact that these calorimeters will not be sufficiently performant with the expected High Luminosity LHC conditions, planned to be started in 2025. The major challenge is to preserve/improve the high performance of the current forward detectors with new devices that can withstand the unprecedented radiation levels and disentangle the very large event pileup. CMS elected two design concepts to be presented in the Phase II Upgrade Technical Proposal Shashlik electromagnetic calorimeter + Hadronic Endcap Rebuild, and High Granularity Calorimeter. The former concept is based on reconstructing the endcap electromagnetic calorimeter with a shashlik design and replacing the active media of the endcap hadron calorimeter with radiation tolerant active media with a possibility to extend the coverage. The latter concept is concentrating on constructing a high granularity (both longitudinally and laterally) calorimeter ...

  18. Optimized Designs for Very Low Temperature Massive Calorimeters

    CERN Document Server

    Pyle, Matt; Sadoulet, Bernard

    2015-01-01

    The baseline energy-resolution performance for the current generation of large-mass, low-temperature calorimeters is $>2$ orders of magnitude worse than theoretical predictions. A detailed study of several calorimetric detectors suggests that a mismatch between the sensor and signal bandwidths is the primary reason for suppressed sensitivity. With this understanding, we propose a detector design in which a thin-film Au pad is directly deposited onto a massive absorber that is then thermally linked to a separately fabricated TES chip via an Au wirebond, providing large electron-phonon coupling (i.e. high signal bandwidth), ease of fabrication, and cosmogenic background suppression. Interestingly, this design strategy is fully compatible with the use of hygroscopic crystals (NaI) as absorbers. An 80-mm diameter Si light detector based upon these design principles, with potential use in both dark matter and neutrinoless double-beta decay, has an estimated baseline energy resolution of 0.35eV, 20x better than cur...

  19. Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnager, V; Kaur, Manjit; Kumar, Arun; Kohli, Jatinder Mohan; Singh, Jas Bir; Acharya, Bannaje Sripathi; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L V; Satyanarayana, B; Sharma, Seema; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Babich, Kanstantsin; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Ladygin, Vladimir; Meshcheryakov, Gleb; Moissenz, P; Petrosian, A; Rogalev, Evgueni; Sergeyev, S; Smirnov, Vitaly; Vishnevski, A V; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N P; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Oulyanov, A; Safronov, S; Semenov, Sergey; Stolin, Viatcheslav; Gribushin, Andrey; Demianov, A; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, Konstantin; Vardanyan, Irina; Yershov, A A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Korablev, Andrey; Khmelnikov, V A; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L K; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Kuzucu, A; Onengüt, G; Ozdes-Koca, N; Ozkurt, Halil; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankocak, Kerem; Gamsizkan, Halil; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Dindar, Kamile; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grinev, B; Lubinsky, V; Senchyshyn, Vitaliy; Anderson, E Walter; Hauptman, John M; Elias, John E; Freeman, Jim; Green, Dan; Heering, Arjan Hendrix; Lazic, Dragoslav; Los, Serguei; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Antchev, Georgy; Arcidy, M; Hazen, Eric; Lawlor, C; Machado, Emanuel; Posch, C; Rohlf, James; Sulak, Lawrence; Varela, F; Wu, Shouxiang; Adams, Mark Raymond; Burchesky, Kyle; Qiang, W; Abdullin, Salavat; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Wang, Lei; Wetstein, Matthew; Ayan, S; Akgun, Ugur; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumus, Kazim; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Wigmans, Richard; Baarmand, Marc M; Mermerkaya, Hamit; Vodopyanov, I; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Martínez, German; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Fisher, Wade Cameron; Tully, Christopher; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T; Pompos, Arnold

    2008-01-01

    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\\l |\\eta| \\le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \\approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed...

  20. Mechanical design and finite element analysis of the SDC central calorimeter

    International Nuclear Information System (INIS)

    When designing scintillating calorimeters for the study of particle interactions resulting from colliding beams, a primary goal is to instrument 100% of the available solid angle. In pursuit of this goal the challenge for mechanical designers is to minimize the amount of structural mass and sill maintain acceptable engineering standards in the design. Argonne National Laboratory, High Energy Physics involvement in the design of a central calorimeter for the SSC started in 1989. Our first proposal was to design a depleted uranium scintillator calorimeter similar to the ZEUS detector presently installed at the HERA electron-proton collider in Hamburg, Germany. Argonne was involved at the time in final assembly of modules for ZEUS that had been designed and constructed at ANL. Due to the cost of using depleted uranium, lead was chosen as the absorber material. In collaboration with Westinghouse Science and Technology Center in Pittsburgh, Pennsylvania we embarked on a program to optimize the use of lead or lead alloys in the construction of the calorimeter. A cast lead design for the calorimeter evolved from this effort. Subsequent to this design, further pressure to reduce costs have now dictated a design which contains lead only in the electromagnetic sections of the calorimeter

  1. Evaluating vacuum phototriodes designed for the PANDA electromagnetic calorimeter

    Science.gov (United States)

    Makónyi, K.; Marcks von Würtemberg, K.; Tegnér, P.-E.; Hansen, K.; Isaksson, L.; Lundin, M.; Schröder, B.; Balkeståhl, L.; Fransson, K.; Johansson, T.; Rosenbaum, C.; Wolke, M.; Erni, W.; Keshelashvili, I.; Krushe, B.

    2014-11-01

    In this work properties of a vacuum phototriode (VPT) and preamplifier unit designed for the electromagnetic calorimeter of the PANDA experiment being built at FAIR are investigated. With the use of lead tungstate and lanthanium bromide scintillators the VPT properties are studied at low photon energies, from tens of keV in the lanthanium bromide measurements and between 10 MeV and 60 MeV in the lead tungstate measurements. At these energies the noise of the VPT unit can be expected to influence its performance significantly. It is shown that the noise contribution to the measured energy resolution, under optimal conditions, is consistent with a fluctuation of (one standard deviation) approximately 200 electrons at the VPT anode. For a lead tungstate crystal this is equivalent to a noise of 1.2 MeV. For lanthanium bromide this makes it possible to use VPTs for gamma ray spectroscopy above a few hundreds of keV without noticeable effects on the energy resolution compared to measurements with a standard photomultiplier.

  2. The design and performance of the electromagnetic calorimeters in Hall C at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Vardan Tadevosyan, Hamlet Mkrtchyan, Arshak Asaturyan, Arthur Mkrtchyan, Simon Zhamkochyan

    2012-12-01

    The design and performance of the electromagnetic calorimeters in the magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers, construction information and comparisons of simulated and experimental results are presented. The design and simulated performance for a new calorimeter to be used in the new SHMS spectrometer is also presented. We have developed and constructed electromagnetic calorimeters from TF-1 type lead-glass blocks for the HMS and SOS magnetic spectrometers at JLab Hall C. The HMS/SOS calorimeters are of identical design and construction except for their total size. Blocks of dimension 10 cm × 10 cm × 70 cm are arranged in four planes and stacked 13 and 11 blocks high in the HMS and SOS respectively. The energy resolution of these calorimeters is better than 6%/√E, and pion/electron (π/e) separation of about 100:1 has been achieved in energy range 1–5 GeV. Good agreement has been observed between the experimental and GEANT4 simulated energy resolutions. The HMS/SOS calorimeters have been used nearly in all Hall C experiments, providing good energy resolution and a high pion suppression factor. No significant deterioration in their performance has been observed in the course of use since 1994. For the SHMS spectrometer, presently under construction, details on the calorimeter design and accompanying GEANT4 simulation efforts are given. A Preshower+Shower design was selected as the most cost-effective among several design choices. The preshower will consist of a layer of 28 modules with TF-1 type lead glass radiators, stacked in two columns. The shower part will consist of 224 modules with F-101 type lead glass radiators, stacked in a “fly's eye” configuration of 14 columns and 16 rows. The active area of 120 × 130 cm(2) will encompass the beam envelope at the calorimeter. The anticipated performance of the new calorimeter is simulated over the full momentum range of the SHMS, predicting

  3. Design, construction and beam tests of the high resolution uranium scintillator calorimeter for ZEUS

    International Nuclear Information System (INIS)

    HERA will collide protons and electrons with energies up to 820 GeV and 30 GeV respectively. Therefore it allows measurements at momentum transfers (Q) which greatly surpass the investigations carried out so far. This extended range in Q will allow investigation of the interactions between the quarks and leptons at a distance scale of the order of 10-18 cm. Two detectors are foreseen at HERA H1 and ZEUS. The design of the ZEUS detector is optimized for the study of neutral and charged current interactions. A calorimeter is a detector which absorbs the total incident energy of a particle while generating a signal proportional to this energy. The ZEUS calorimeter is built of alternating layers of dense absorber plates (238U) and active layers of scintillator material with a fast readout system via wavelength shifters, light guides and photomultiplyers. The main subject of this thesis is the description of this calorimeter and its performance. After a short introduction to HERA and the physics topics, the importance of the quality of a calorimeter is pointed out and a brief overview of the ZEUS detector is given. In ch. 3 the principles of high resolution hadron calorimetry and the studies which led to the design of the ZEUS-calorimeter are discussed. Ch. 4 describes the mechanical design of the ZEUS forward calorimeter, the mechanical finite element calculations, and the production of the calorimeter modules at NIKHEF. Finally ch. 6 and 5 show the results of beam tests of the ZEUS forward calorimeter prototypes and the final full size forward calorimeter modules. (author). 59 refs.; 115 figs.; 29 tabs

  4. The construction of the graphite calorimeter GR9 at LNE-LNHB (geometrical and technical consideration); Construction du calorimetre en graphite GR9 au LNE-LNHB (caracteristiques techniques et geometriques)

    Energy Technology Data Exchange (ETDEWEB)

    Ostrowsky, A.; Daures, J

    2008-07-01

    Calorimetry is the most direct dosimetric technique to reach absorbed dose. A calorimeter gives direct access to the energy imparted to matter by ionizing radiation per mass unit by measuring the heat quantity Q produced under irradiation in its sensitive element which is thermally insulated. Graphite was chosen as construction material because all the energy imparted to graphite by ionizing radiation is converted into heat. Thermistors are used for temperature measurements as well as for the electrical heating of the different bodies of the calorimeter. The construction of a calorimeter is the result of a compromise between dosimetric requirements and mechanical constraints. The difficulties encountered are examined and the solutions chosen are detailed. All technical data are gathered in this document. The aim is to provide a practical operative instruction and guidance document, which can help interested laboratories in designing such an instrument. The electrical and thermal tests have shown a good behaviour of the GR9 calorimeter.

  5. Design and status of the Mu2e electromagnetic calorimeter

    CERN Document Server

    Atanov, N; Budagov, J; Carosi, R; Cervelli, F; Colao, F; Cordelli, M; Corradi, G; Dane', E; Davydov, Yu I; Di Falco, S; Donati, S; Donghia, R; Echenard, B; Flood, K; Giovannella, S; Glagolev, V; Grancagnolo, F; Happacher, F; Hitlin, D G; Martini, M; Miscetti, S; Miyashita, T; Morescalchi, L; Murat, P; Pasciuto, D; Pezzullo, G; Porter, F; Saputi, A; Sarra, I; Soleti, S R; Spinella, F; Tassielli, G; Tereshchenko, V; Usubov, Z; Zhu, R Y

    2016-01-01

    The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorim...

  6. Design and expected performance of a fast scintillator hadron calorimeter

    International Nuclear Information System (INIS)

    A typical pulse from the 807 calorimeter is shown. This was generated by 4 GeV electrons but the pulses from hadrons and at different energies are not significantly different. The width and shape of this pulse comes from the convolution of a number of sources: (a) The time spread of energy deposition by a shower including time of flight of slow protons and neutrons, (b) scintillator phosphor rise and decay times, (c) shifter rise and decay times, (d) phototube response, (e) time delays in the light collection from different parts of the calorimeter and time dispersion in transmission. The objective of the first phase of this study was to isolate these spearate contributions, estimate how they could be speeded up and find what costs are involved. In the second phase we constructed an extremely crude calorimeter whose pulses should have the same characteristic as in a real device. With this we have observed signals whose mean width was 7 nsec and whose width at 10% of maximum height was 15 nsec. Clipping could reduce these widths to 6 and 12 nsec respectively. We conclude that gate times of less than 20 nsec would be appropriate for such a calorimeter

  7. ANL four-meter calorimeter design and operation manual

    International Nuclear Information System (INIS)

    The four-meter fuel rod calorimetric system measures the thermal power produced by radioactive decay of fuel rods containing Pu. The Pu mass is related to the measured power through the weighted average of the product of the isotopic decay energies and the decay constants of the Pu isotopes present. U content has no effect since the thermal power produced by the U nuclides is insignificant when compared to Pu. Radiations from Pu are alpha particles and low-energy photons. This calorimeter will measure samples producing power up to 1.5 watts at a rate of one sample every 120 min. The instrument consists of a data-acquisition module made up of a microprocessor, with an 8K-byte nonvolatile memory, a control cabinet and the calorimeter chamber

  8. ANL four-meter calorimeter design and operation manual

    Energy Technology Data Exchange (ETDEWEB)

    Perry, R.B.; Lewis, R.N.; Youngdahl, G.A.; Jung, E.A.; Roche, C.T.

    1980-02-01

    The four-meter fuel rod calorimetric system measures the thermal power produced by radioactive decay of fuel rods containing Pu. The Pu mass is related to the measured power through the weighted average of the product of the isotopic decay energies and the decay constants of the Pu isotopes present. U content has no effect since the thermal power produced by the U nuclides is insignificant when compared to Pu. Radiations from Pu are alpha particles and low-energy photons. This calorimeter will measure samples producing power up to 1.5 watts at a rate of one sample every 120 min. The instrument consists of a data-acquisition module made up of a microprocessor, with an 8K-byte nonvolatile memory, a control cabinet and the calorimeter chamber. (FS)

  9. Structure design and enviromental test of BGO calorimeter for satellite DAMPE

    Science.gov (United States)

    Hu, Yiming; Feng, Changqing; Zhang, Yunlong; Chen, Dengyi; Chang, Jin

    2016-07-01

    The Dark Matter Particle Explorer, DAMPE, is a new designed satellite developed for the new Innovation 2020 program of Chinese Academy of Sciences. As the most important payload of China's first scientific satellite for detecting dark matter, the primary purposes of BGO calorimeter is to measure the energy of incident high energy electrons and gamma rays (5GeV-10TeV) and to identify hadron and electronics. BGO calorimeter also provides an important background discriminator by measuring the energy deposition due to the particle shower that produced by the e^{±}, γ and imaging their shower development profile. Structure design of BGO calorimeter is described in this paper. The new designed BGO calorimeter consists of 308 BGO crystals coupled with photomultiplier tubes on its two ends. The envelop size of the BGO calorimeter is 907.5mm×907.5mm×494.5mm,and the weight of which is 1051.4Kg. The most important purpose of mechanical design is how to package so heavy crystals into a detector as required arrangement and to make sure reliability and safety. This paper describes the results of vibration tests using the Flight Module of the BGO Calorimeter for the DAMPE satellite. During the vibration tests, no degradation of the mechanical assembly was observed. After random or sinusoidal vibrations, there was no significant changes of the frequency signatures observed during the modal surveys. The comparison of results of cosmic ray tests before and after the vibration shows no change in the performance of the BGO calorimeter.

  10. Bulk-assay calorimeter: Part 1. System design and operation. Part 2. Calibration and testing

    International Nuclear Information System (INIS)

    The Bulk-Assay Calorimeter is designed to measure the thermal power emitted by plutonium-containing samples. The sample power range of the instrument is 1.4 to 22.4 W. The instrument package consists of the calorimeter measurement chamber, the control circuit power bin, and the data acquisition system. Two sample preheating chambers and five calorimeter canisters for containing the samples are included. A set of 32 test points which monitor voltages at points within the calorimeter and its control circuitry are accessed by the data acquisition system. The use of the test points is described. System start-up and checkout are described. Sample assay and preheater operation procedures are given. The data acquisition system and data analysis software are described. The calorimeter was calibrated at 23 points with heat sources from 1.4 to 22.4 watts. The combined measurement error varied with sample power from 1.4% to 0.1% over the range of calibration measurements. Circuit diagrams for the calorimeter and schematics for the data acquisition system are included

  11. Technical Design Report BASE

    CERN Document Server

    Ulmer, S; Smorra, C; Blaum, K; Franke, K; Matsuda, Y; Nagahama, H; Quint, W; Walz, J; Mooser, A; Schneider, G; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2013-01-01

    We propose a direct high-precision measurement of the magnetic moment, or g-factor, of a single antiproton stored in a cryogenic Penning trap. Currently the most precise value of the magnetic moment of the antiproton is extracted from super-hyperfine spectroscopy of antiprotonic helium atoms, and known with a relative precision of only about 3 10^{-3}. BASE aims at a measurement with a relative precision of 10^{-9} or better. A Letter of Intent which was submitted to CERN was welcomed by the SPSC and we were invited to submit this Technical Design Report.

  12. Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Babich, Kanstantsin; Golutvin, Igor; Kalagin, Vladimir; Kamenev, Alexey; Konoplianikov, V; Kosarev, Ivan; Moissenz, K; Moissenz, P; Oleynik, Danila; Petrosian, A; Rogalev, Evgueni; Semenov, Roman; Sergeyev, S; Shmatov, Sergey; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Druzhkin, Dmitry; Ivanov, Alexander; Kudinov, Vladimir; Orlov, Alexandre; Smetannikov, Vladimir; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; de Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankoc, K; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grynev, B; Lyubynskiy, Vadym; Senchyshyn, Vitaliy; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; ODell, V; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gusum, K; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Wigmans, Richard; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T

    2008-01-01

    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\\% to 5\\%.

  13. CALOR89: The code system for calorimeter analysis and design

    International Nuclear Information System (INIS)

    As part of a strong experimental high energy physics program, a substantial effort must be involved in calculational analysis of the detector system. This calculational capability must be fundamentally sound and based on previous interchange between theoretical calculations and experimental test programs. The CALOR89[1-6] system for analyzing calorimeters offers a solid approach for investigating all facets of detector systems and has been used in many calculational studies. CALOR89 is one of two major code systems recommended for analysis of SSC detector systems

  14. Windows Calorimeter Control (WinCal) program computer software design description

    International Nuclear Information System (INIS)

    The Windows Calorimeter Control (WinCal) Program System Design Description contains a discussion of the design details for the WinCal product. Information in this document will assist a developer in maintaining the WinCal system. The content of this document follows the guidance in WHC-CM-3-10, Software Engineering Standards, Standard for Software User Documentation

  15. Design and performance of a vacuum-bottle solid-state calorimeter

    International Nuclear Information System (INIS)

    EG and G Mound Applied Technologies calorimetry personnel have developed a small, thermos-bottle solid-state calorimeter, which is now undergoing performance testing at Los Alamos National Laboratory. The thermos-bottle solid-state calorimeter is an evaluation prototype for characterizing the heat output of small heat standards and other homogeneous heat sources. The current maximum sample size is 3.5 in. long with a diameter of 0.8 in. The overall size of the thermos bottle and thermoelectric cooling device is 9.25 in. high by 3.75 in. diameter and less than 3 lb. Coupling this unit with compact electronics and a laptop computer makes this calorimeter easily hand carried by a single individual. This compactness was achieved by servo controlling the reference temperature below room temperature and replacing the water bath used in conventional calorimeter design with the thermos-bottle insulator. Other design features will also be discussed. The performance of the calorimeter will be presented

  16. Design and performance of a vacuum-bottle solid-state calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Bracken, D.S.; Biddle, R. [Los Alamos National Lab., NM (United States); Cech, R. [Global Manufacturing Solutions, Inc., Miamisburg, OH (United States)

    1997-11-01

    EG and G Mound Applied Technologies calorimetry personnel have developed a small, thermos-bottle solid-state calorimeter, which is now undergoing performance testing at Los Alamos National Laboratory. The thermos-bottle solid-state calorimeter is an evaluation prototype for characterizing the heat output of small heat standards and other homogeneous heat sources. The current maximum sample size is 3.5 in. long with a diameter of 0.8 in. The overall size of the thermos bottle and thermoelectric cooling device is 9.25 in. high by 3.75 in. diameter and less than 3 lb. Coupling this unit with compact electronics and a laptop computer makes this calorimeter easily hand carried by a single individual. This compactness was achieved by servo controlling the reference temperature below room temperature and replacing the water bath used in conventional calorimeter design with the thermos-bottle insulator. Other design features will also be discussed. The performance of the calorimeter will be presented.

  17. Design and construction of a prototype vaporization calorimeter for the assay of radioisotopic samples

    International Nuclear Information System (INIS)

    A prototype vaporization calorimeter has been designed and constructed for use in the assay of low power output radioisotopic samples. The prototype calorimeter design was based on that of a previous experimental instrument used by H.P. Stephens, to establish the feasibility of the vaporization calorimetry technique for this type of power measurement. The calorimeter is composed of a mechanical calorimeter assembly together with a data acquisition and control system. Detailed drawings of the calorimeter assembly are included and additional drawings are referenced. The data acquisition system is based on an HP 9825A programmable calculator. A description of the hardware is provided together with a listing of all system software programs. The operating procedure is outlined, including initial setup and operation of all related equipment. Preliminary system performance was evaluated by making a series of four measurements on two nominal 1.5W samples and on a nominal 0.75W sample. Data for these measurements indicate that the absolute accuracy (one standard deviation) is approx. = 0.0035W in this power range, resulting in an estimated relative one standard deviation accuracy of 0.24% at 1.5W and 0.48% at 0.75W

  18. Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider

    OpenAIRE

    Repond et al., J.; CALICE Collaboration

    2008-01-01

    The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. T...

  19. Technical specification for plate fabrication for the ATLAS Tile Hadron Calorimeter

    International Nuclear Information System (INIS)

    The Atlas Collaboration, at the European Organization for Nuclear Research (CERN), proposes to build a general purpose proton-proton detector for the Large Hadron Collider (LHC), located in Geneva, Switzerland. The ATLAS collaboration consists of approximately 100 international institutions (universities and research laboratories) with a worldwide distribution. The ATLAS detector includes a large scintillating tile calorimeter using iron as the absorber material. This detector will be used to identify and measure the by-products of proton-proton collisions that occur at the symmetric center. The design of this detector is unique in that the absorber plates are oriented perpendicular to the colliding beam axis, rather than parallel, as is done in most other similar detectors to date. A simplified view of the detector is shown in the figure below

  20. GEM Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-31

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high p{sub T} physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence the name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, E{sub T}. The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high p{sub T} physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds.

  1. GEM Technical Design Report

    International Nuclear Information System (INIS)

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high pT physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence the name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, ET. The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high pT physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds

  2. Design, status and test of the Mu2e crystal calorimeter

    CERN Document Server

    Atanov, N; Budagov, J; Carosi, R; Cervelli, F; Colao, F; Cordelli, M; Corradi, G; Danè, E; Davydov, Y I; Di Falco, S; Donati, S; Donghia, R; Echenard, B; Flood, K; Giovannella, S; Glagolev, V; Grancagnolo, F; Happacher, F; Hitlin, D G; Martini, M; Miscetti, S; Miyashita, T; Morescalchi, L; Murat, P; Piacentino, G M; Pezzullo, G; Raffaelli, F; Saputi, A; Sarra, I; Spinella, F; Tassielli, G; Tereshchenko, V; Usubov, Z; Zhu, R Y

    2016-01-01

    The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with about 700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. These crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.

  3. Design and characterisation of a YAG(Ce) calorimeter for proton Computed Tomography application

    International Nuclear Information System (INIS)

    The design and the characterization of a calorimeter system, aimed at measuring the residual energy in a proton Computed Tomography (pCT) apparatus, is described. The calorimeter has a 6 × 6 cm2 active area to fully cover the tracker area of the pCT system, being 10 cm thick it is able to stop up to 200 MeV protons and sustain 1 MHz particle rate (average rate on the whole area). The YAG(Ce) scintillator is promising for charged particle detection applications where high-count rate, good energy resolution and compact photodiode readout, not influenced by magnetic fields, are of importance. The aim of this work is to show data acquired with proton beam energy up to 175 MeV and to discuss the performances of this calorimeter

  4. Family reunion for the UA2 calorimeter

    CERN Multimedia

    Abha Eli Phoboo

    2015-01-01

    After many years in CERN’s Microcosm exhibition, the last surviving UA2 central calorimeter module has been moved to Hall 175, the technical development laboratory of the ATLAS Tile Hadronic Calorimeter (Tilecal). The UA2 and ATLAS calorimeters are cousins, as both were designed by Otto Gildemeister. Now side by side, the calorimeters illustrate the progress made in sampling organic scintillator calorimeters over the past 35 years.   The ATLAS Tile Calorimeter prototypes (left) and the UA2 central calorimeter (right) in Hall 175. (Image: Mario Campanelli/ATLAS.) From 1981 to 1990, the UA2 experiment was one of the two detectors on CERN’s flagship accelerator, the SPS. At the heart of the UA2 detector was the central calorimeter. It was made up of 24 slices – each weighing four tonnes – arranged like orange segments around the collision point. These calorimeter slices played a central role in the research carried out by UA2 for the discovery of W bosons...

  5. The design and construction of a Pb/scintillator sampling calorimeter with wavelength shifter fiber optic readout

    International Nuclear Information System (INIS)

    A Pb/scintillator sampling calorimeter covering the pseudorapidity interval of η = 0.83 to 4.20 has been designed and constructed for Experiment 814 of Brookhaven National Laboratory. The calorimeter uses wavelength shifting optical fibers for readout. Such fibers allow the construction of a highly granular and longitudinally compact device. A novel scheme for coupling a fiber to a scintillator plate has been designed that yields a high photoelectron response. Longitudinally, the calorimeter has a depth of four interaction lengths divided into two electromagnetic sections and two hadronic sections of 0.4, 0.4, 1.6, and 1.6 interaction lengths, respectively. (orig.)

  6. Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter

    OpenAIRE

    Batarin, V. A.; Butler, J.; Davidenko, A. M.; Derevschikov, A. A.; Goncharenko, Y. M.; Grishin, V. N.; Kachanov, V A.; Khodyrev, V. Y.; Konstantinov, A. S.; Kormilitsin, V. A.; Kravtsov, V. I.; Kubota, Y.; Lukanin, V. S.; Matulenko, Y. A.; Melnick, Y. M.

    2005-01-01

    A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.

  7. Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter

    CERN Document Server

    Batarin, V A; Davidenko, A M; Derevshchikov, A A; Goncharenko, Yu M; Grishin, V N; Kachanov, V A; Khodyrev, V Yu; Konstantinov, A S; Kormilitsin, V A; Kravtsov, V I; Kubota, Y; Lukanin, V S; Matulenko, Yu A; Melnik, Yu M; Meshchanin, A P; Mikhalin, N E; Minaev, N G; Mochalov, V V; Morozov, D A; Nogach, L V; Ryazantsev, A V; Semenov, P A; Semenov, V K; Shestermanov, K E; Soloviev, L F; Stone, S; Uzunian, A V; Vasilev, A N; Yakutin, A E; Yarba, J V

    2006-01-01

    A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.

  8. Calorimeter detectors

    CERN Document Server

    de Barbaro, P; The ATLAS collaboration

    2013-01-01

    Although the instantaneous and integrated luminosity in HL-LHC will be far higher than the LHC detectors were originally designed for, the Barrel calorimeters of the four experiments are expected to continue to perform well  throughout the Phase II program. The conditions for the End-Cap calorimeters are far more challenging and whilst some detectors will require relatively modest changes, others require far more substantial upgrades. We present the results of longevity and performance studies for the calorimeter systems of the four main LHC experiments and outline the upgrade options under consideration. We include a discussion of the R&D required to make the final technology choices for the upgraded detectors.

  9. Visualizing interdependencies in technical design

    NARCIS (Netherlands)

    Oosterman, B.J.; Gaalman, G.J.C.; Kuijpers, F.P.J.; Riiahuhta, A.; Pulkkinen, A.

    2001-01-01

    The control and understanding of complex design processes is an important issue in practice and theory. Recent research shows that documentation and analysis of technical interactions between design tasks (using Design Structure Matrices) gives a thorough understanding of the underlying complex stru

  10. Design and test beam studies for the CASTOR calorimeter of the CMS experiment

    International Nuclear Information System (INIS)

    CASTOR is a calorimeter designed for the very forward region of the CMS experiment at the LHC: 5.2I deep calorimeter. The electronics has to deal with a high occupancy and a high dynamic range (104) to measure minimum ionizing particles and full beam energy (7 TeV) jets. The charge of the PMT's is digitized for every bunch crossing (25 ns) and sent as 1.6 Gbit/s streams via 78 optical links to the service cavern. There FGPA's calculate trigger bits, buffer the data and communicate with the CMS systems. A granularity of 224 channels allows to reconstruct shower profiles. Electrons, hadrons and muons have been measured in test beams. The optical response has been extracted to be ∼9-12 photoelectrons(ph.e.)/readout-unit for muons, ∼30ph.e./GeV for electrons and ∼13ph.e./GeV for high energetic pions.

  11. Design and Implementation of the New D0 Level-1 Calorimeter Trigger

    Energy Technology Data Exchange (ETDEWEB)

    Abolins, M.; Adams, M.; Adams, T.; Aguilo, E.; Anderson, J.; Bagby, L.; Ban, J.; Barberis, E.; Beale, S.; Benitez, J.; Biehl, J.; /Columbia U. /DAPNIA, Saclay /Delhi U. /Fermilab /Florida State U. /Indiana U. /Michigan State U. /Northeastern U. /Rice U. /Southern Methodist U. /University Coll., Dublin

    2007-09-01

    Increasing luminosity at the Fermilab Tevatron collider has led the D0 collaboration to make improvements to its detector beyond those already in place for Run IIa, which began in March 2001. One of the cornerstones of this Run IIb upgrade is a completely redesigned level-1 calorimeter trigger system. The new system employs novel architecture and algorithms to retain high efficiency for interesting events while substantially increasing rejection of background. We describe the design and implementation of the new level-1 calorimeter trigger hardware and discuss its performance during Run IIb data taking. In addition to strengthening the physics capabilities of D0, this trigger system will provide valuable insight into the operation of analogous devices to be used at LHC experiments.

  12. Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    CERN Document Server

    Abdullin, Salavat; Acharya, Bannaje Sripathi; Adam, Nadia; Adams, Mark Raymond; Akchurin, Nural; Akgun, Ugur; Albayrak, Elif Asli; Anderson, E Walter; Antchev, Georgy; Arcidy, M; Ayan, S; Aydin, Sezgin; Aziz, Tariq; Baarmand, Marc M; Babich, Kanstantsin; Baden, Drew; Bakirci, Mustafa Numan; Banerjee, Sunanda; Banerjee, Sudeshna; Bard, Robert; Barnes, Virgil E; Bawa, Harinder Singh; Baiatian, G; Bencze, Gyorgy; Beri, Suman Bala; Berntzon, Lisa; Bhatnagar, Vipin; Bhatti, Anwar; Bodek, Arie; Bose, Suvadeep; Bose, Tulika; Budd, Howard; Burchesky, Kyle; Camporesi, Tiziano; Cankocak, Kerem; Carrell, Kenneth Wayne; Cerci, Salim; Chendvankar, Sanjay; Chung, Yeon Sei; Clarida, Warren; Cremaldi, Lucien Marcus; Cushman, Priscilla; Damgov, Jordan; De Barbaro, Pawel; Debbins, Paul; Deliomeroglu, Mehmet; Demianov, A; de Visser, Theo; Deshpande, Pandurang Vishnu; Díaz, Jonathan; Dimitrov, Lubomir; Dugad, Shashikant; Dumanoglu, Isa; Duru, Firdevs; Efthymiopoulos, I; Elias, John E; Elvira, D; Emeliantchik, Igor; Eno, Sarah Catherine; Ershov, Alexander; Erturk, Sefa; Esen, Selda; Eskut, Eda; Fenyvesi, Andras; Fisher, Wade Cameron; Freeman, Jim; Ganguli, Som N; Gaultney, Vanessa; Gamsizkan, Halil; Gavrilov, Vladimir; Genchev, Vladimir; Gleyzer, Sergei V; Golutvin, Igor; Goncharov, Petr; Grassi, Tullio; Green, Dan; Gribushin, Andrey; Grinev, B; Gurtu, Atul; Murat Güler, A; Gülmez, Erhan; Gümüs, K; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Halyo, Valerie; Hashemi, Majid; Hauptman, John M; Hazen, Eric; Heering, Arjan Hendrix; Heister, Arno; Hunt, Adam; Ilyina, N; Ingram, D; Isiksal, Engin; Jarvis, Chad; Jeong, Chiyoung; Johnson, Kurtis F; Jones, John; Kaftanov, Vitali; Kalagin, Vladimir; Kalinin, Alexey; Kalmani, Suresh Devendrappa; Karmgard, Daniel John; Kaur, Manjit; Kaya, Mithat; Kaya, Ozlem; Kayis-Topaksu, A; Kellogg, Richard G; Khmelnikov, Alexander; Kim, Heejong; Kisselevich, I; Kodolova, Olga; Kohli, Jatinder Mohan; Kolossov, V; Korablev, Andrey; Korneev, Yury; Kosarev, Ivan; Kramer, Laird; Krinitsyn, Alexander; Krishnaswamy, Marthi Ramaswamy; Krokhotin, Andrey; Kryshkin, V; Kuleshov, Sergey; Kumar, Arun; Kunori, Shuichi; Laasanen, Alvin T; Ladygin, Vladimir; Laird, Edward; Landsberg, Greg; Laszlo, Andras; Lawlor, C; Lazic, Dragoslav; Lee, Sang Joon; Levchuk, Leonid; Linn, Stephan; Litvintsev, Dmitri; Lobolo, L; Los, Serguei; Lubinsky, V; Lukanin, Vladimir; Ma, Yousi; Machado, Emanuel; Maity, Manas; Majumder, Gobinda; Mans, Jeremy; Marlow, Daniel; Markowitz, Pete; Martínez, German; Mazumdar, Kajari; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mescheryakov, G; Mestvirishvili, Alexi; Miller, Michael; Möller, A; Mohammadi-Najafabadi, M; Moissenz, P; Mondal, Naba Kumar; Mossolov, Vladimir; Nagaraj, P; Narasimham, Vemuri Syamala; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Onengüt, G; Ozkan, Cigdem; Ozkurt, Halil; Ozkorucuklu, Suat; Ozok, Ferhat; Paktinat, S; Pal, Andras; Patil, Mandakini Ravindra; Penzo, Aldo; Petrushanko, Sergey; Petrosian, A; Pikalov, Vladimir; Piperov, Stefan; Podrasky, V; Polatoz, A; Pompos, Arnold; Popescu, Sorina; Posch, C; Pozdnyakov, Andrey; Qian, Weiming; Ralich, Robert; Reddy, L; Reidy, Jim; Rogalev, Evgueni; Roh, Youn; Rohlf, James; Ronzhin, Anatoly; Ruchti, Randy; Ryazanov, Anton; Safronov, Grigory; Sanders, David A; Sanzeni, Christopher; Sarycheva, Ludmila; Satyanarayana, B; Schmidt, Ianos; Sekmen, Sezen; Semenov, Sergey; Senchishin, V; Sergeyev, S; Serin, Meltem; Sever, Ramazan; Singh, B; Singh, Jas Bir; Sirunyan, Albert M; Skuja, Andris; Sharma, Seema; Sherwood, Brian; Shumeiko, Nikolai; Smirnov, Vitaly; Sogut, Kenan; Sonmez, Nasuf; Sorokin, Pavel; Spezziga, Mario; Stefanovich, R; Stolin, Viatcheslav; Sudhakar, Katta; Sulak, Lawrence; Suzuki, Ichiro; Talov, Vladimir; Teplov, Konstantin; Thomas, Ray; Tonwar, Suresh C; Topakli, Huseyin; Tully, Christopher; Turchanovich, L; Ulyanov, A; Vanini, A; Vankov, Ivan; Vardanyan, Irina; Varela, F; Vergili, Mehmet; Verma, Piyush; Vesztergombi, Gyorgy; Vidal, Richard; Vishnevskiy, Alexander; Vlassov, E; Vodopiyanov, Igor; Volobouev, Igor; Volkov, Alexey; Volodko, Anton; Wang, Lei; Werner, Jeremy Scott; Wetstein, Matthew; Winn, Dave; Wigmans, Richard; Whitmore, Juliana; Wu, Shouxiang; Yazgan, Efe; Yetkin, Taylan; Zálán, Peter; Zarubin, Anatoli; Zeyrek, Mehmet

    2008-01-01

    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing $\\et$ measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS.

  13. Software studies of GLD calorimeter

    Indian Academy of Sciences (India)

    H Matsunaga

    2007-12-01

    The baseline design of the GLD calorimeter is scintillator-strip arrays interleaved with absorber plates. We present preliminary performance studies of the hit clustering with this calorimeter using a simulator. Also, simulation results of a `digital' calorimeter, which is an option of the GLD calorimeter, are presented.

  14. Argonne mechanical design proposal for the ATLAS hadron calorimeter

    International Nuclear Information System (INIS)

    The uniqueness of the Argonne design is given here: (1) by overlapping the spacer plates the compression load is carried through the module without affecting the scintillator slots; (2) flat thin straps are used in place of tie rods; (3) a supermodule is constructed of six 1 meter modules; (4) it is not necessary to drill holes through the scintillator; (5) absorber structure can be assembled independent of scintillator; (6) straps provide better load distribution across the plates; and (7) this design, as currently drawn, does not include internal sourcing, but does not preclude it being used

  15. Design and Application of the Reconstruction Software for the BaBar Calorimeter

    International Nuclear Information System (INIS)

    The BaBar high energy physics experiment will be in operation at the PEP-II asymmetric e+e- collider in Spring 1999. The primary purpose of the experiment is the investigation of CP violation in the neutral B meson system. The electromagnetic calorimeter forms a central part of the experiment and new techniques are employed in data acquisition and reconstruction software to maximize the capability of this device. The use of a matched digital filter in the feature extraction in the front end electronics is presented. The performance of the filter in the presence of the expected high levels of soft photon background from the machine is evaluated. The high luminosity of the PEP-II machine and the demands on the precision of the calorimeter require reliable software that allows for increased physics capability. BaBar has selected C++ as its primary programming language and object oriented analysis and design as its coding paradigm. The application of this technology to the reconstruction software for the calorimeter is presented. The design of the systems for clustering, cluster division, track matching, particle identification and global calibration is discussed with emphasis on the provisions in the design for increased physics capability as levels of understanding of the detector increase. The CP violating channel B0 → J/Ψ Ks0 has been studied in the two lepton, two π0 final state. The contribution of this channel to the evaluation of the angle sin 2β of the unitarity triangle is compared to that from the charged pion final state. An error of 0.34 on this quantity is expected after 1 year of running at design luminosity

  16. Design and Application of the Reconstruction Software for the BaBar Calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Strother, Philip David; /Imperial Coll., London

    2006-07-07

    The BaBar high energy physics experiment will be in operation at the PEP-II asymmetric e{sup +}e{sup -} collider in Spring 1999. The primary purpose of the experiment is the investigation of CP violation in the neutral B meson system. The electromagnetic calorimeter forms a central part of the experiment and new techniques are employed in data acquisition and reconstruction software to maximize the capability of this device. The use of a matched digital filter in the feature extraction in the front end electronics is presented. The performance of the filter in the presence of the expected high levels of soft photon background from the machine is evaluated. The high luminosity of the PEP-II machine and the demands on the precision of the calorimeter require reliable software that allows for increased physics capability. BaBar has selected C++ as its primary programming language and object oriented analysis and design as its coding paradigm. The application of this technology to the reconstruction software for the calorimeter is presented. The design of the systems for clustering, cluster division, track matching, particle identification and global calibration is discussed with emphasis on the provisions in the design for increased physics capability as levels of understanding of the detector increase. The CP violating channel B{sup 0} {yields} J/{Psi}K{sub S}{sup 0} has been studied in the two lepton, two {pi}{sup 0} final state. The contribution of this channel to the evaluation of the angle sin 2{beta} of the unitarity triangle is compared to that from the charged pion final state. An error of 0.34 on this quantity is expected after 1 year of running at design luminosity.

  17. Design and R&D of very forward calorimeters for detectors at future e+ e- collider

    CERN Document Server

    Bozovic-Jelisavcic, I

    2015-01-01

    Detectors at future e+ e-collider need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered particles. Design optimized for the ILC collider using Monte Carlo simulations is presented. Sensor prototypes have been produced and dedicated FE ASICs have been developed and tested. For the first time, sensors have been connected to the front-end and ADC ASICs and tested in an electron beam. Results on the performance are discussed.

  18. TECHNICAL ASPECTS OF JEWELRY DESIGN

    Directory of Open Access Journals (Sweden)

    V. P. Lugovoy

    2014-11-01

    Full Text Available The paper considers an influence of technical factors on jewelry design and provides an analysis of literature data that reveals that main investigations in this field are devoted to the following three problems, namely: problems pertaining to usage of up-to-date IT-technologies in design modeling; material science problems pertaining to influence of decorative and technological properties of the applied materials on esthetic quality of objects and also problems pertaining to manufacturing technology and decorative processing of jewelry.  An important role is played by systematic module approach to training of designers and specialists involved in designing and manufacturing of jewelry. 

  19. Calorimeter insertion

    CERN Multimedia

    2006-01-01

    Calorimeter insertion between toroids in the ATLAS experiment detector Calorimeters are surrounding the inner detector. Calorimeters will absorb and measure the energies of the most charged and neutral particles after the collisions. The saved energy in the calorimeter is detected and converted to signals that are taken out with data taking electronics.

  20. Calorimeter design-aspects for neutral beam injection on W7-X

    Energy Technology Data Exchange (ETDEWEB)

    Holtum, D., E-mail: holtum@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85740 Garching (Germany); Froeschle, M.; Heinemann, B. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85740 Garching (Germany); Liebe, T. [Fa. Xenos GmbH, Jugendstr. 2, D-81667 Muenchen (Germany); Nocentini, R.; Riedl, R.; Rong, P. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85740 Garching (Germany); Schubert, W. [Fa. Xenos GmbH, Jugendstr. 2, D-81667 Muenchen (Germany); Staebler, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85740 Garching (Germany)

    2011-10-15

    Neutral Beam Injection (NBI) is one of the heating systems for Wendelstein 7-X (W7-X). The beam power of the NBI is measured calorimetrically. Using the knowledge gained from ASDEX-Upgrade operation, the complete calorimeter was re-designed. The design-aspects and the necessary improvements for operation on W7-X are described in this paper. The main aspects improved concern: (i) the adapted slope of the winding drum at the lift, (ii) the adjustable acceleration/deceleration ramp and integrated position sensors, (iii) the improvements of panels in the body, (iv) the accessibility for mounting panels, (v) the water-distribution, and (vi) the centering of the body on the support to fix and reproduce the measuring position. The manufacturing is in progress, installation will start in 2011 and the commissioning is scheduled for the end of 2014.

  1. Calorimeter design-aspects for neutral beam injection on W7-X

    International Nuclear Information System (INIS)

    Neutral Beam Injection (NBI) is one of the heating systems for Wendelstein 7-X (W7-X). The beam power of the NBI is measured calorimetrically. Using the knowledge gained from ASDEX-Upgrade operation, the complete calorimeter was re-designed. The design-aspects and the necessary improvements for operation on W7-X are described in this paper. The main aspects improved concern: (i) the adapted slope of the winding drum at the lift, (ii) the adjustable acceleration/deceleration ramp and integrated position sensors, (iii) the improvements of panels in the body, (iv) the accessibility for mounting panels, (v) the water-distribution, and (vi) the centering of the body on the support to fix and reproduce the measuring position. The manufacturing is in progress, installation will start in 2011 and the commissioning is scheduled for the end of 2014.

  2. Design Studies of the Calorimeter Systems for the sPHENIX Experiment at RHIC and Future Upgrade Plans

    International Nuclear Information System (INIS)

    The PHENIX Experiment at RHIC is planning a series of major upgrades that will enable a comprehensive measurement of jets in relativistic heavy ion collisions, provide enhanced physics capabilities for studying nucleon-nucleus and polarized proton collisions, and allow a detailed study of electron-nucleus collisions at the Electron Ion Collider at Brookhaven (eRHIC). The first of these upgrades, sPHENIX, will be based on the former BaBar magnet and will include a hadronic calorimeter and new electromagnetic calorimeter that will cover ±1.1 units in pseudorapidity and 2π in azimuth in the central region, resulting in a factor of 6 increase in acceptance over the present PHENIX detector. The electromagnetic calorimeter will be a tungsten scintillating fiber design with a radiation length ∼ 7 mm and a Moliere radius ∼ 2 cm. It will have a total depth of ∼ 18 radiation lengths and an energy resolution ∼ 15%/√E. The hadronic calorimeter will consist of steel plates with scintillating tiles in between that are read out with wavelength shifting fibers, It will have a total depth of ∼ 5 interaction lengths and an energy resolution 100%/√E. Both calorimeters will use silicon photomultipliers as the readout sensor. Detailed design studies and Monte Carlo simulations for both calorimeters have been carried out and prototype detectors have been constructed and tested in a test beam at Fermilab in February 2014. This contribution describes these design studies for the sPHENIX experiment and its future upgrade plans at RHIC

  3. Design Studies of the Calorimeter Systems for the sPHENIX Experiment at RHIC and Future Upgrade Plans

    Science.gov (United States)

    Woody, C.; Kistenev, E.; PHENIX Collaboration

    2015-02-01

    The PHENIX Experiment at RHIC is planning a series of major upgrades that will enable a comprehensive measurement of jets in relativistic heavy ion collisions, provide enhanced physics capabilities for studying nucleon-nucleus and polarized proton collisions, and allow a detailed study of electron-nucleus collisions at the Electron Ion Collider at Brookhaven (eRHIC). The first of these upgrades, sPHENIX, will be based on the former BaBar magnet and will include a hadronic calorimeter and new electromagnetic calorimeter that will cover ±1.1 units in pseudorapidity and 2π in azimuth in the central region, resulting in a factor of 6 increase in acceptance over the present PHENIX detector. The electromagnetic calorimeter will be a tungsten scintillating fiber design with a radiation length ~ 7 mm and a Moliere radius ~ 2 cm. It will have a total depth of ~ 18 radiation lengths and an energy resolution ~ 15%/√E. The hadronic calorimeter will consist of steel plates with scintillating tiles in between that are read out with wavelength shifting fibers, It will have a total depth of ~ 5 interaction lengths and an energy resolution 100%/√E. Both calorimeters will use silicon photomultipliers as the readout sensor. Detailed design studies and Monte Carlo simulations for both calorimeters have been carried out and prototype detectors have been constructed and tested in a test beam at Fermilab in February 2014. This contribution describes these design studies for the sPHENIX experiment and its future upgrade plans at RHIC.

  4. Belle II Technical Design Report

    CERN Document Server

    Abe, T; Adamczyk, K; Ahn, S; Aihara, H; Akai, K; Aloi, M; Andricek, L; Aoki, K; Arai, Y; Arefiev, A; Arinstein, K; Arita, Y; Asner, D M; Aulchenko, V; Aushev, T; Aziz, T; Bakich, A M; Balagura, V; Ban, Y; Barberio, E; Barvich, T; Belous, K; Bergauer, T; Bhardwaj, V; Bhuyan, B; Blyth, S; Bondar, A; Bonvicini, G; Bozek, A; Bracko, M; Brodzicka, J; Brovchenko, O; Browder, T E; Cao, G; Chang, M -C; Chang, P; Chao, Y; Chekelian, V; Chen, A; Chen, K -F; Chen, P; Cheon, B G; Chiang, C -C; Chistov, R; Cho, K; Choi, S -K; Chung, K; Comerma, A; Cooney, M; Cowley, D E; Critchlow, T; Dalseno, J; Danilov, M; Dieguez, A; Dierlamm, A; Dillon, M; Dingfelder, J; Dolenec, R; Dolezal, Z; Drasal, Z; Drutskoy, A; Dungel, W; Dutta, D; Eidelman, S; Enomoto, A; Epifanov, D; Esen, S; Fast, J E; Feindt, M; Garcia, M Fernandez; Fifield, T; Fischer, P; Flanagan, J; Fourletov, S; Fourletova, J; Freixas, L; Frey, A; Friedl, M; Fruehwirth, R; Fujii, H; Fujikawa, M; Fukuma, Y; Funakoshi, Y; Furukawa, K; Fuster, J; Gabyshev, N; Cueto, A Gaspar de Valenzuela; Garmash, A; Garrido, L; Geisler, Ch; Gfall, I; Goh, Y M; Golob, B; Gorton, I; Grzymkowski, R; Guo, H; Ha, H; Haba, J; Hara, K; Hara, T; Haruyama, T; Hayasaka, K; Hayashi, K; Hayashii, H; Heck, M; Heindl, S; Heller, C; Hemperek, T; Higuchi, T; Horii, Y; Hou, W -S; Hsiung, Y B; Huang, C -H; Hwang, S; Hyun, H J; Igarashi, Y; Iglesias, C; Iida, Y; Iijima, T; Imamura, M; Inami, K; Irmler, C; Ishizuka, M; Itagaki, K; Itoh, R; Iwabuchi, M; Iwai, G; Iwai, M; Iwasaki, M; Iwasaki, M; Iwasaki, Y; Iwashita, T; Iwata, S; Jang, H; Ji, X; Jinno, T; Jones, M; Julius, T; Kageyama, T; Kah, D H; Kakuno, H; Kamitani, T; Kanazawa, K; Kapusta, P; Kataoka, S U; Katayama, N; Kawai, M; Kawai, Y; Kawasaki, T; Kennedy, J; Kichimi, H; Kikuchi, M; Kiesling, C; Kim, B K; Kim, G N; Kim, H J; Kim, H O; Kim, J -B; Kim, J H; Kim, M J; Kim, S K; Kim, K T; Kim, T Y; Kinoshita, K; Kishi, K; Kisielewski, B; van Dam, K Kleese; Knopf, J; Ko, B R; Koch, M; Kodys, P; Koffmane, C; Koga, Y; Kohriki, T; Koike, S; Koiso, H; Kondo, Y; Korpar, S; Kouzes, R T; Kreidl, Ch; Kreps, M; Krizan, P; Krokovny, P; Krueger, H; Kruth, A; Kuhn, W; Kuhr, T; Kumar, R; Kumita, T; Kupper, S; Kuzmin, A; Kvasnicka, P; Kwon, Y -J; Lacasta, C; Lange, J S; Lee, I -S; Lee, M J; Lee, M W; Lee, S -H; Lemarenko, M; Li, J; Li, W D; Li, Y; Libby, J; Limosani, A; Liu, C; Liu, H; Liu, Y; Liu, Z; Liventsev, D; Virto, A Lopez; Makida, Y; Mao, Z P; Marinas, C; Masuzawa, M; Matvienko, D; Mitaroff, W; Miyabayashi, K; Miyata, H; Miyazaki, Y; Miyoshi, T; Mizuk, R; Mohanty, G B; Mohapatra, D; Moll, A; Mori, T; Morita, A; Morita, Y; Moser, H -G; Martin, D Moya; Mueller, T; Muenchow, D; Murakami, J; Myung, S S; Nagamine, T; Nakamura, I; Nakamura, T T; Nakano, E; Nakano, H; Nakao, M; Nakazawa, H; Nam, S -H; Natkaniec, Z; Nedelkovska, E; Negishi, K; Neubauer, S; Ng, C; Ninkovic, J; Nishida, S; Nishimura, K; Novikov, E; Nozaki, T; Ogawa, S; Ohmi, K; Ohnishi, Y; Ohshima, T; Ohuchi, N; Oide, K; Olsen, S L; Ono, M; Ono, Y; Onuki, Y; Ostrowicz, W; Ozaki, H; Pakhlov, P; Pakhlova, G; Palka, H; Park, H; Park, H K; Peak, L S; Peng, T; Peric, I; Pernicka, M; Pestotnik, R; Petric, M; Piilonen, L E; Poluektov, A; Prim, M; Prothmann, K; Regimbal, K; Reisert, B; Richter, R H; Riera-Babures, J; Ritter, A; Ritter, A; Ritter, M; Roehrken, M; Rorie, J; Rosen, M; Rozanska, M; Ruckman, L; Rummel, S; Rusinov, V; Russell, R M; Ryu, S; Sahoo, H; Sakai, K; Sakai, Y; Santelj, L; Sasaki, T; Sato, N; Sato, Y; Scheirich, J; Schieck, J; Schwanda, C; Schwartz, A J; Schwenker, B; Seljak, A; Senyo, K; Seon, O -S; Sevior, M E; Shapkin, M; Shebalin, V; Shen, C P; Shibuya, H; Shiizuka, S; Shiu, J -G; Shwartz, B; Simon, F; Simonis, H J; Singh, J B; Sinha, R; Sitarz, M; Smerkol, P; Sokolov, A; Solovieva, E; Stanic, S; Staric, M; Stypula, J; Suetsugu, Y; Sugihara, S; Sugimura, T; Sumisawa, K; Sumiyoshi, T; Suzuki, K; Suzuki, S Y; Takagaki, H; Takasaki, F; Takeichi, H; Takubo, Y; Tanaka, M; Tanaka, S; Taniguchi, N; Tarkovsky, E; Tatishvili, G; Tawada, M; Taylor, G N; Teramoto, Y; Tikhomirov, I; Trabelsi, K; Tsuboyama, T; Tsunada, K; Tu, Y -C; Uchida, T; Uehara, S; Ueno, K; Uglov, T; Unno, Y; Uno, S; Urquijo, P; Ushiroda, Y; Usov, Y; Vahsen, S; Valentan, M; Vanhoefer, P; Varner, G; Varvell, K E; Vazquez, P; Vila, I; Vilella, E; Vinokurova, A; Visniakov, J; Vos, M; Wang, C H; Wang, J; Wang, M -Z; Wang, P; Wassatch, A; Watanabe, M; Watase, Y; Weiler, T; Wermes, N; Wescott, R E; White, E; Wicht, J; Widhalm, L; Williams, K M; Won, E; Xu, H; Yabsley, B D; Yamamoto, H; Yamaoka, H; Yamaoka, Y; Yamauchi, M; Yin, Y; Yoon, H; Yu, J; Yuan, C Z; Yusa, Y; Zander, D; Zdybal, M; Zhang, Z P; Zhao, J; Zhao, L; Zhao, Z; Zhilich, V; Zhou, P; Zhulanov, V; Zivko, T; Zupanc, A; Zyukova, O

    2010-01-01

    The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been proposed. A new international collaboration Belle-II, is being formed. The Technical Design Report presents physics motivation, basic methods of the accelerator upgrade, as well as key improvements of the detector.

  5. A design of scintillator tiles read out by surface-mounted SiPMs for a future hadron calorimeter

    International Nuclear Information System (INIS)

    Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten millions of channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve high response to Minimum Ionizing Particles (MIPs) and also good areal uniformity. Cosmic-ray measurements confirms high 1-MIP response for scintillator tiles with an optimized cavity design. Uniformity measurements by scanning the tile area using focused electrons from a beta source show excellent response uniformity. This optimized design is well beyond the requirements for a precision hadron calorimeter.

  6. Design and application of calorimeters for monitoring biological processes in stirred tank bioreactors

    OpenAIRE

    Regestein, Lars

    2013-01-01

    Developing and improving online monitoring techniques for processes is always a matter of interest for industrial and research applications. Independent of kind and complexity of the reaction, measuring the heat generation (calorimetry) is a universal tool for process monitoring. Therefore, two new calorimetric measurement techniques (chip calorimeter and reactor calorimeter) for process monitoring in stirred tank reactors were developed, validated and applied to several biological systems. ...

  7. Design of a lead-glass drift calorimeter with MWPC detection

    International Nuclear Information System (INIS)

    A drift collection calorimeter having a combined radiator and field-shaping structure made of lead-glass tubing is described. A high-resistance metallic layer is formed by reduction of the lead oxide at the surface of the glass and forms a continuous voltage divider for drift-field shaping. The energy resolution of such a calorimeter is modeled, for several configurations, by the Monte Carlo technique

  8. Design of a Portable Test Facility for the ATLAS Tile Calorimeter Front-End Electronics Verification

    CERN Document Server

    Kim, H Y; The ATLAS collaboration; Carrio, F; Moreno, P; Masike, T; Reed, R; Sandrock, C; Schettino, V; Shalyugin, A; Solans, C; Souza, J; Suter, R; Usai, G; Valero, A

    2013-01-01

    The stand-alone test-bench deployed in the past for the verification of the Tile Calorimeter (TileCal) front-end electronics is reaching the end of its life cycle. A new version of the test-bench has been designed and built with the aim of improving the portability and exploring new technologies for future versions of the TileCal read-out electronics. An FPGA based motherboard with an embedded hardware processor and a few dedicated daughter-boards are used to implement all the functionalities needed to interface with the front-end electronics (TTC, G-Link, CANbus) and to verify the functionalities using electronic signals and LED pulses. The new device is portable and performs well, allowing the validation in realistic conditions of the data transmission rate. We discuss the system implementation and all the tests required to gain full confidence in the operation of the front-end electronics of the TileCal in the ATLAS detector.

  9. COMPASS Accelerator Design Technical Overview

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Emilio; Dolgashev, Valery; Tantawi, Sami; Neilson, Jeff; /SLAC

    2016-03-14

    This report is a survey of technical options for generating a MeV-class accelerator for space based science applications. The survey was performed focusing on the primary technical requirements of the accelerator in the context of a satellite environment with its unique challenges of limited electrical power (PE), thermal isolation, dimensions, payload requirement and electrical isolation.

  10. The CMS forward calorimeter prototype design studies and Omega(c)0 search at E781 experiment at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Ayan, Ahmet Sedat

    2004-05-01

    In the fit part, the Compact Muon Solenoid (CMS) forward calorimeter design studies are presented. The forward calorimeter consists of quartz fibers embedded in a steel absorber. Radiation damage studies of the quartz fiber and the absorber as well as the results of the first pre-production prototype PPP-I are presented. In the second part, the {Omega}{sub c}{sup 0}search studies at the SELEX (E781) experiment at FermiLab are presented. 107 {+-} 22 {Omega}{sub c}{sup 0} events are observed in three decay modes. The relative branching ratio ({Omega}{sub c}{sup 0} {yields} {Omega}{sup -}{pi}{sup -}{pi}{sup +}{pi}{sup +})/{Beta}({Omega}{sub c}{sup 0} {yields} {Omega}{sup -}{pi}{sup +}) is measured as 2.00 {+-} 0.45(stat) {+-} 0.32(sys).

  11. Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Vesztergombi, Gyorgy; Zálán, Peter; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sudhakar, Katta; Verma, Piyush; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Mescheryakov, G; Sergeyev, S; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Stolin, Viatcheslav; Ulyanov, A; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Kuzucu-Polatoz, A; Onengüt, G; Ozdes-Koca, N; Cankocak, Kerem; Ozok, Ferhat; Serin-Zeyrek, M; Sever, Ramazan; Zeyrek, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grinev, B; Lubinsky, V; Senchishin, V; Anderson, E Walter; Hauptman, John M; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Lazic, Dragoslav; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Antchev, Georgy; Hazen, Eric; Lawlor, C; Machado, Emanuel; Posch, C; Rohlf, James; Wu, Shouxiang; Adams, Mark Raymond; Burchesky, Kyle; Qiang, W; Abdullin, Salavat; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumu, K; Thomas, Ray; Baarmand, Marc M; Ralich, Robert; Vodopiyanov, Igor; Cushman, Priscilla; Heering, Arjan Hendrix; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Mans, Jeremy; Tully, Christopher; De Barbaro, Pawel; Bodek, Arie; Budd, Howard; Chung, Yeon Sei; Haelen, T; Imboden, Matthias; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T; Pompos, Arnold

    2007-01-01

    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%.

  12. Concepts and design of the CMS High Granularity Calorimeter Level 1 Trigger

    CERN Document Server

    Sauvan, Jean-baptiste

    2016-01-01

    The CMS experiment has chosen a novel high granularity calorimeter for the forward region as part of its planned upgrade for the high luminosity LHC. The calorimeter will have a fine segmentation in both the transverse and longitudinal directions and will be the first such calorimeter specifically optimised for particle flow reconstruction to operate at a colliding beam experiment. The high granularity results in around six million readout channels in total and so presents a significant challenge in terms of data manipulation and processing for the trigger; the trigger data volumes will be an order of magnitude above those currently handled at CMS. In addition, the high luminosity will result in an average of 140 to 200 interactions per bunch crossing, giving a huge background rate in the forward region that needs to be efficiently reduced by the trigger algorithms. Efficient data reduction and reconstruction algorithms making use of the fine segmentation of the detector have been simulated and evaluated. The...

  13. Design and testing of a calorimeter for measurements on electrochemical reactions with gas evolution

    International Nuclear Information System (INIS)

    A heat-conduction calorimeter suitable for the study of electrochemical processes has been constructed. The reaction vessel of 25 cm3 volume was fitted with electrodes, calibration heater, stirrer, thermocouple, and thin Teflon tube for addition of liquid. Gas evolved could leave the vessel through a gas-outlet tube. Good thermal conductivity was achieved by mounting nine thermocouple plates between the vessel and the surrounding heat sink and by letting the heat sink be in good thermal contact with the thermostat bath. The calorimeter was tested by measurements on the electrolysis of water and of heavy water and found to have an accuracy better than 0.2 per cent. (author)

  14. Search for and selection of novel heavy scintillator crystals for calorimeter design for future high-energy colliders

    International Nuclear Information System (INIS)

    The discovery of some particles (Higgs, top,..) foreseen by theoretical models should be achieved at future colliders allowing to reach an energy scale of about 1 TeV. Efficient detectors must be designed to handle the very high luminosity of the LHC collider at CERN. In the intermediate mass region, MZ-2MZ, the diphoton decay mode of a Higgs boson produced inclusively or in association with W boson or a toponium gives good chance of observation. A very high resolution calorimeter with photon angle reconstruction and pion identification capability should detect a Higgs signal with high probability. So a homogeneous crystal calorimeter seems to be suitable. Because of the high luminosity and the high radiation level, a search for a new heavy scintillator has been undertaken. It must have a good radiation hardness (>0.5 MRad in a year) and a fast luminescence decay time (<30 ns). Among 50 crystals or glasses of specific chemical composition tested in transmission, luminescence, decay time, γ/neutrons radiation and light yield, cerium fluoride seems best suited for LHC. The necessity to have a good photon resolution in the intermediate Higgs mass region led us to optimise by Monte Carlo simulations the geometry of the calorimeter, the uniformisation of the light collection and crystal intercalibration parameters. (orig.)

  15. Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider

    CERN Document Server

    Repond, J; Cass, S; Yu, J; Hawkes, C M; Mikami, Y; Miller, O; Watson, N K; Wilson, J A; Mavromanolakis, G; Thomson, M A; Ward, D R; Yan, W; Badaud, F; Boumediene, D; Crloganu, C; Cornat, R; Gay, P; Gris, P; Manen, S; Morisseau, F; Royer, L; Blazey, G C; Chakraborty, D; Dyshkant, A; Francis, K; Hedin, D; Lima, G; Zutshi, V; Hostachy, J Y; Morin, L; Garutti, E; Korbel, V; Sefkow, F; Groll, M; Kim, G; Kim, D W; Lee, K; Lee, S; Kawagoe, K; Bowerman, Y; Tamura, D A; Dauncey, P D; Magnan, A M; Noronha, C; Yilmaz, H; Zorba, O; Bartsch, V; Butterworth, J M; Postranecky, M; Warren, M; Wing, M; Faucci Giannelli, M; Green, M G; Salvatore, F; Wu, T; Bailey, D; Barlow, R J; Kelly, M; Snow, S; Thompson, R J; Danilov, M; Kochetkov, V; Cheremushkinskaya, B; Baranova, N; Ermolov, P; Karmanov, D; Korolev, M; Merkin, M; Lomonosov, A; Voronin, M V; Bouquet, B; Callier, S; Dulucq, F; Fleury, J; Li, H; Martin-Chassard, G; Richard, F; dela Taille, C; Pöschl, R; Raux, L; Ruan, M; Seguin-Moreau, N; Wicek, F; Zhang, Z; Anduze, M; Boudry, V; Brient, J C; Clerc, C; Gaycken, G; Jauffret, C; Karar, A; Mora de Freitas, P; Musat, G; Reinhard, M; Rougé, A; Sanchez, A L; Vanel, J C; Videau, H; Zácek, J; Cvach, J; Gallus, P; Havranek, M; Janata, M; Marcisovsky, M; Polak, I; Popule, J; Tomasek, L; Tomasek, M; Ruzicka, P; Sícho, P; Smolik, J; Vrba, V; Zaleisak, J; Arestov, Yu; Baird, A; Halsall, R N; Nam, S W; Park, I H; Yang, J

    2008-01-01

    The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics f...

  16. The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

    Science.gov (United States)

    Kilbourne, Caroline A.; Adams, Joseph S.; Brekosky, Regis P.; Chiao, Meng P.; Chervenak, James A.; Eckart, Megan E.; Figueroa-Feliciano, Enectali; Galeazzi, Masimilliano; Grein, Christoph; Jhabvala, Christine A.; Kelley, Richard L.; Leutenegger, Maurice A.; McCammon, Dan; Porter, F. Scott; Szymkowiak, Andrew E.; Watanabe, Tomomi; Zhao, Jun

    2016-01-01

    The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

  17. Explicating the Sustainable Design of Technical Artefacts

    DEFF Research Database (Denmark)

    Vissonova, Karina

    2016-01-01

    Sustainable design of technical artefacts is referred to as if it were a kind of design with some specific characteristics. However, in design research and practice alike, there appears to be a lack of shared conceptions of what such a design might entail. Furthermore, we have no clear grounds for...... evaluating what makes the sustainable design solutions permissible. The lack of shared conceptions is largely due to ambiguities associated with the notion of sustainability. In response to these challenges, the aim of my study is to offer a definition of sustainable design of technical artefacts. I argue...... that despite the ambiguities, there are discernible necessary and sufficient conditions by which the design may qualify as the sustainable kind. My claims are constructed based on two assumptions: the first being the presence of side effects of the design of technical artefacts, and the second being...

  18. Technical Design of Flexible Sustainable Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik

    2003-01-01

    The paper presents technical designs of potential future flexible energy systems in Denmark, which will be able both to balance production and demand and to secure voltage and frequency requirements on the grid....

  19. A Design of Scintillator Tiles Read Out by Surface-Mounted SiPMs for a Future Hadron Calorimeter

    CERN Document Server

    Liu, Yong; Caudron, Julien; Chau, Phi; Krause, Sascha; Masetti, Lucia; Schäfer, Ulrich; Spreckels, Rouven; Tapprogge, Stefan; Wanke, Rainer

    2015-01-01

    Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve a high response to a Minimum Ionizing Particles (MIP) and also good spatial uniformity. The single-MIP response for scintillator tiles with an optimized cavity design has been measured usi...

  20. Mechanical and Thermal Design of the CEBAF Hall A Beam Calorimeter

    CERN Document Server

    Bevins, Michael E; Degtiarenko, Pavel; Dillon-Townes, Lawrence A; Freyberger, Arne; Gilman, Ronald; Saha, Arun; Slachtouski, Stephanie

    2005-01-01

    A calorimeter has been proposed to provide 0.5% - 1.0% absolute measurements of beam current in the Hall A end station of the Thomas Jefferson National Accelerator Facility (JLab) CEBAF machine. Silver and copper calorimeters built in the 1960's achieved precisions of about 1%. Modern powder metallurgy processes have produced high density, high thermal conductivity tungsten-copper composite materials that will minimize beam loss while maintaining a rapid thermal response time. Heat leaks will be minimized by mounting the mass in vacuum on glass ceramic mounts. A conduction cooling scheme utilizes an advanced carbon fiber compliant thermal interface material. Transient finite difference and finite element models were developed to estimate heat leaks and thermal response times.

  1. Design of the Readout Electronics for the Qualification Model of DAMPE BGO Calorimeter

    OpenAIRE

    Feng, Changqing; Zhang, Deliang; Zhang, Junbin; Gao, Shanshan; Yang, Di; Zhang, Yunlong; Liu, Shubin; An, Qi

    2014-01-01

    The DAMPE (DArk Matter Particle Explorer) is a scientific satellite being developed in China, aimed at cosmic ray study, gamma ray astronomy, and searching for the clue of dark matter particles, with a planned mission period of more than 3 years and an orbit altitude of about 500 km. The BGO Calorimeter, which consists of 308 BGO (Bismuth Germanate Oxid) crystal bars, 616 PMTs (photomultiplier tubes) and 1848 dynode signals, has approximately 32 radiation lengths. It is a crucial sub-detector...

  2. Technical progress in pipeline design and construction

    Energy Technology Data Exchange (ETDEWEB)

    Hausken, K.B.

    1995-12-31

    This paper considers the technical progress in offshore pipeline construction with limitation to some general subjects covering pipeline design, installation and start-up. In future the use of limit state pipeline design philosophy, may be implemented as an alternative to the stress based design commonly used to day giving a potential for further optimisation of the pipeline design and consequently reduction of the initial investment. Comprehensive research and development efforts in Norway in the second half of the 1970`s, made it technically feasible to cross the deep water Norwegian Trench in the 1980`s. In addition, the development of several offshore pipeline systems until to day including gas distribution systems to the European continent, have brought Norway to the forefront of technical expertise

  3. The SDC central calorimeter

    International Nuclear Information System (INIS)

    An overview of the calorimeter being designed and constructed by Solenoidal Detector Collaboration (SDC) for use at the Superconducting SuperCollider is presented. The collaboration have chosen to build a sampling calorimeter using scintillating tile with wavelength-shifter fiber readout as the detector medium, and absorber media of lead and iron for the electromagnetic and hadronic compartments. This choice was based on a substantial amount of R ampersand D and Monte Carlo simulation calculations, which showed that it both met the necessary experimental specifications in addition to being a cost effect design

  4. Design Principles and Operational Results of the Cryogenic System for the ATLAS Liquid Argon Calorimeter

    CERN Document Server

    Fabre, C; Chalifour, M; Gonidec, G; Passardi, Giorgio; Petit, P; Pezzetti, M; Wicek, F

    2009-01-01

    The ATLAS liquid argon calorimeter housed in three independent cryostats containing a total argon volume of about 78 m3 has been installed in the underground cavern. The three detectors have been cooled down following stringent temperature gradient limits and have been filled with liquid argon. The cryostats are now in a stable condition for periods going up to almost two years. The temperature uniformity within each of the three detector volumes is found to be within 70 mK rms, while the temperature stability stays below 5 mK rms.

  5. Design, status and test of the Mu2e crystal calorimeter

    OpenAIRE

    Atanov, N.; Baranov, V; Budagov, J.; Carosi, R.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Danè, E.; Davydov, Y. I.; Di Falco, S; S. Donati; Donghia, R.; Echenard, B.; Flood, K

    2016-01-01

    The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter whil...

  6. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Cerda Alberich, Leonor; The ATLAS collaboration

    2015-01-01

    The Tile Calorimeter of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. The performance of the calorimeter has been studied employing cosmic ray muons and the large sample of proton-proton collisions acquired during the Run 1 of LHC (2010-2012). Results on the calorimeter performance on absolute energy scale, timing, noise and associated stabilities are presented. The results show that the Tile Calorimeter performance is within the design requirements of the detector.

  7. Design, R&D and status of the crystal calorimeter for the Mu2e experiment

    CERN Document Server

    ,

    2016-01-01

    The Mu2e Experiment at Fermilab will search for coherent, neutrinoless conversion of muons into electrons in the field of a nucleus, with a sensitivity improvement of a factor of 10^4 over previous experiments. Such a charged lepton flavor-violating reaction probes new physics at a scale inaccessible with direct searches at either present or planned high energy colliders. The conversion electron is mono-energetic with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set a limit on the ratio between the conversion rate and the capture rate, R_{\\mu e}, of < 6 x 10^{-17} (@ 90% CL). In this paper, the physics motivation for Mu2e and the current status of the electromagnetic calorimeter project are briefly presented.

  8. D0 Silicon Upgrade: End Calorimeter Transfer Bridge Design and Installation Procedures

    International Nuclear Information System (INIS)

    The North Endcap Calorimeter (NEC) is to be moved from the clean room to the north sidewalk in preparation for the final installation on the DO detector center beam. In order to make this move, the cable bridge must be 'flattened' and the NEC lifted to move over it. The detector is moved west, approximately 24 feet, while the moveable counting house remains stationary. This movement allows the cable bridge to 'flatten' i.e. become horizontal. The cable bridge lowering is steadied and stabilized by 7.5 ton hoist mounted on the moveable counting house. By moving the detector to lower the bridge, a vacancy has been created in the pit that must be filled to the level of the clean room rail elevation. This filler will consist of concrete shield blocks, stacked in two rows. These rows are spaced appropriately to match the wheel base of the EC transporter. A steel plate is placed on top of each row of shield blocks and leveled to the elevation of the clean room rails. Steel plates will be installed and leveled on the north sidewalk similar to those used on the south sidewalk for the CC installation. These plates are used as rails for the Hilman rollers, bearing surfaces for shim blocks used during lifting and anchors for holding the transporter extension units and the transfer bridge. After the plates are installed, the transfer bridge is put in place, spanning the cable bridge, shimmed and leveled. The transporter extension units are positioned next to the transfer bridge on the north sidewalk. With the completion of this prep work, the actual transfer of the NEC from the clean room can begin. The NEC is pulled from the clean room with the same mechanism (cyl. and chain) that was used for the CC and the pull anchor point will be located at the end of the concrete blocks. The NEC will come out of the north west door in the clean room and move along the temporary rail plates in the pit until it is in line with the transfer bridge. At this point the NEC is ready to be

  9. The NOvA Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Ayres, D.S.; Drake, G.R.; Goodman, M.C.; Grudzinski, J.J.; Guarino, V.J.; Talaga, R.L.; Zhao, A.; /Argonne; Stamoulis, P.; Stiliaris, E.; Tzanakos, G.; Zois, M.; /Athens U. /Caltech /UCLA /Fermilab /College de France /Harvard U. /Indiana U. /Lebedev Inst. /Michigan State U. /Minnesota U., Duluth /Minnesota U.

    2007-10-08

    Technical Design Report (TDR) describes the preliminary design of the NOvA accelerator upgrades, NOvA detectors, detector halls and detector sites. Compared to the March 2006 and November 2006 NOvA Conceptual Design Reports (CDR), critical value engineering studies have been completed and the alternatives still active in the CDR have been narrowed to achieve a preliminary technical design ready for a Critical Decision 2 review. Many aspects of NOvA described this TDR are complete to a level far beyond a preliminary design. In particular, the access road to the NOvA Far Detector site in Minnesota has an advanced technical design at a level appropriate for a Critical Decision 3a review. Several components of the accelerator upgrade and new neutrino detectors also have advanced technical designs appropriate for a Critical Decision 3a review. Chapter 1 is an Executive Summary with a short description of the NOvA project. Chapter 2 describes how the Fermilab NuMI beam will provide a narrow band beam of neutrinos for NOvA. Chapter 3 gives an updated overview of the scientific basis for the NOvA experiment, focusing on the primary goal to extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations and measure the sin{sup 2}(2{theta}{sub 13}) parameter. This parameter has not been measured in any previous experiment and NOvA would extend the search by about an order of magnitude beyond the current limit. A secondary goal is to measure the dominant mode oscillation parameters, sin{sup 2}(2{theta}{sub 23}) and {Delta}m{sub 32}{sup 2} to a more precise level than previous experiments. Additional physics goals for NOvA are also discussed. Chapter 4 describes the Scientific Design Criteria which the Fermilab accelerator complex, NOvA detectors and NOvA detector sites must satisfy to meet the physics goals discussed in Chapter 3. Chapter 5 is an overview of the NOvA project. The changes in the design relative to the NOvA CDR are discussed. Chapter 6 summarizes the NOv

  10. Design of a Portable Test Facility for the ATLAS Tile Calorimeter Front-End Electronics Verification

    CERN Document Server

    Kim, HY; The ATLAS collaboration; Carrio, F; Moreno, P; Masike, T; Reed, R; Sandrock, C; Schettino, V; Shalyugin, A; Solans, C; Souza, J; Suter, R; Usai, G; Valero, A

    2013-01-01

    An FPGA-based motherboard with an embedded hardware processor is used to implement a portable test- bench for the full certification of Tile Calorimeter front-end electronics in the ATLAS experiment at CERN. This upgrade will also allow testing future versions of the TileCal read-out electronics as well. Because of its lightness the new facility is highly portable, allowing on-detector validation using sophisticated algorithms. The new system comprises a front-end GUI running on an external portable computer which controls the motherboard. It also includes several dedicated daughter-boards that exercise the different specialized functionalities of the system. Apart from being used to evaluate different technologies for the future upgrades, it will be used to certify the consolidation of the electronics by identifying low frequency failures. The results of the tests presented here show that new system is well suited for the 2013 ATLAS Long Shutdown. We discuss all requirements necessary to give full confidence...

  11. Design and construction of a calorimeter for the measurement of radiation doses in a nuclear reactor

    International Nuclear Information System (INIS)

    The amount of energy deposited by the radiation in an absorber system, in radiation dose units was established, the Reactor Triga Mark III core of the Mexican Nuclear Center was used as radiation source. The calorimetric method was used, which gives us a direct measurement in energy units. The total dose was measured, that is, no difference was made between the different forms of radiation that operate with the system. A calorimeter was made with the following materials: stainless steel jacket, aluminium absorber material and thermometers of iron alloy. The calibration system was made for the heating and cooling technique, obtaining with the experimental data the value of the pseudo period constant. With that value and using the fit derived equation, the dose values were established for the G-21 position of the reactor core. It was established that the obtained dose is a function of the operation reactor time before the measurement, at the same a lot of propositions are presented in order to improve this technique, as for the used materials as to the obtaining the most fit equations. A comparison was made between the theoretical calculated dose and the experimentally obtained data with the calorimetric technique. (author)

  12. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Shimizu, S; The ATLAS collaboration

    2012-01-01

    The Tile Calorimeter is the central section of the ATLAS hadronic calorimeter. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. Because of its very good signal to noise ratio it is also useful for the identification and reconstruction of muons. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 4900 cells, each viewed by two photomultipliers. The calorimeter response is monitored to better than 1% using radioactive source, laser, and electronic charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of pp collisions acquired in 2011 and 2012. Results on the calorimeter performance will be presented, including the absolute energy scale, time resolution, and associated stabilities. These results demonstrate that the Tile Calorimeter is performing well within the design requirements and is giving essential ...

  13. The liquid argon calorimeter subsystem

    International Nuclear Information System (INIS)

    During the past several months, Tennessee, Mississippi, and the Oak Ridge National Laboratory have been coordinating efforts to benchmark the CALOR89 code system against the DO and HELIOS prototype calorimeter data, and to use the CALOR89 system to generate currently needed data for radiation damage studies, signal collection time, and compensation characteristics of various calorimeter designs. This report describes these results and gives our plans and projected budgets for the following year. 8 refs., 5 figs

  14. SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

    Energy Technology Data Exchange (ETDEWEB)

    Entezari, N [Ryerson University, Toronto, Ontario (Canada); Renaud, J [McGill University, Montreal, Quebec (Canada); Ly, D [Waterloo University, Waterloo, Ontario (Canada); Sarfehnia, A [Sunnybrook Hospital, Toronto, ON (Canada)

    2015-06-15

    Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise {sub (}ΔΤ{sub )} according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608.

  15. SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

    International Nuclear Information System (INIS)

    Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise (ΔΤ) according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608

  16. The AMS-02 electromagnetic calorimeter

    CERN Document Server

    Cadoux, F; Chambert-Hermel, V; Chen, G; Chen, H; Coignet, G; Di Falco, S; Dubois, J M; Falchini, E; Franzoso, A; Fougeron, D; Fouque, N; Galeotti, S; Girard, L; Goy, C; Hermel, R; Incagli, M; Kossakowski, R; Lieunard, B; Liu, Y; Liu, Z; Lomtadze, T A; Maestro, P; Marrocchesi, P S; Paoletti, R; Pilo, F; Rosier-Lees, S; Spinella, F; Turini, N; Valle, G D; Venanzoni, G; Vialle, J P; Yu, Z; Zhuang, H

    2002-01-01

    The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).

  17. SuperB Technical Design Report

    CERN Document Server

    Baszczyk, M; Kolodziej, J; Kucewicz, W; Sapor, M; Jeremie, A; Pous, E Grauges; Bruno, G E; De Robertis, G; Diacono, D; Donvito, G; Fusco, P; Gargano, F; Giordano, F; Loddo, F; Loparco, F; Maggi, G P; Manzari, V; Mazziotta, M N; Nappi, E; Palano, A; Santeramo, B; Sgura, I; Silvestris, L; Spinoso, V; Eigen, G; Zalieckas, J; Zhuo, Z; Jenkovszky, L; Balbi, G; Boldini, M; Bonacorsi, D; Cafaro, V; D'Antone, I; Dallavalle, G M; Di Sipio, R; Fabbri, F; Fabbri, L; Gabrielli, A; Galli, D; Giacomelli, P; Giordano, V; Giorgi, F M; Grandi, C; Lax, I; Meo, S Lo; Marconi, U; Montanari, A; Pellegrini, G; Piccinini, M; Rovelli, T; Cesari, N Semprini; Torromeo, G; Tosi, N; Travaglini, R; Vagnoni, V M; Valentinetti, S; Villa, M; Zoccoli, A; Caron, J -F; Hearty, C; Lu, P F -T; Mattison, T S; McKenna, J A; So, R Y -C; Barnyakov, M Yu; Blinov, V E; Botov, A A; Druzhinin, V P; Golubev, V B; Kononov, S A; Kravchenko, E A; Levichev, E B; Onuchin, A P; Serednyakov, S I; Shtol, D A; Skovpen, Y I; Solodov, E P; Cardini, A; Carpinelli, M; Chao, D S -T; Cheng, C H; Doll, D A; Echenard, B; Flood, K; Hanson, J; Hitlin, D G; Ongmongkolkul, P; Porter, F C; Zhu, R Y; Randazzo, N; Burelo, E De La Cruz; Zheng, Y; Campos, P; De Silva, M; Kathirgamaraju, A; Meadows, B; Pushpawela, B; Shi, Y; Sokoloff, M; Castro, G Lopez; Ciaschini, V; Franchini, P; Giacomini, F; Paolini, A; Polania, G A Calderon; Laczek, S; Romanowicz, P; Szybinski, B; Czuchry, M; Flis, L; Harezlak, D; Kocot, J; Radecki, M; Sterzel, M; Szepieniec, T; Szymocha, T; Wójcik, P; Andreotti, M; Baldini, W; Calabrese, R; Carassiti, V; Cibinetto, G; Ramusino, A Cotta; Evangelisti, F; Gianoli, A; Luppi, E; Malaguti, R; Manzali, M; Melchiorri, M; Munerato, M; Padoan, C; Santoro, V; Tomassetti, L; Beretta, M M; Biagini, M; Boscolo, M; Capitolo, E; de Sangro, R; Esposito, M; Felici, G; Finocchiaro, G; Gatta, M; Gatti, C; Guiducci, S; Lauciani, S; Patteri, P; Peruzzi, I; Piccolo, M; Raimondi, P; Rama, M; Sanelli, C; Tomassini, S; Fabbricatore, P; Delepine, D; Santos, M A Reyes; Chrzaszcz, M; Grzymkowski, R; Knap, P; Kotula, J; Lesiak, T; Ludwin, J; Michalowski, J; Pawlik, B; Rachwal, B; Stodulski, M; Wiechczynski, J; Witek, M; Zawiejski, L; Zdybal, M; Aushev, V Y; Ustynov, A; Arnaud, N; Bambade, P; Beigbeder, C; Bogard, F; Borsato, M; Breton, D; Brossard, J; Burmistrov, L; Charlet, D; Chaumat, V; Dadoun, O; Berni, M El; Maalmi, J; Puill, V; Rimbault, C; Stocchi, A; Tocut, V; Variola, A; Wallon, S; Wormser, G; Grancagnolo, F; Ben-Haim, E; Sitt, S; Baylac, M; Bourrion, O; Deconto, J -M; Martinez, Y Gomez; Monseu, N; Muraz, J -F; Real, J -S; Vescovi, C; Cenci, R; Jawahery, A; Roberts, D; Twedt, E W; Cheaib, R; Lindemann, D; Nderitu, S; Patel, P; Robertson, S H; Swersky, D; Warburton, A; Flores, E Cuautle; Sanchez, G Toledo; Biassoni, P; Bombelli, L; Citterio, M; Coelli, S; Fiorini, C; Liberali, V; Monti, M; Nasri, B; Neri, N; Palombo, F; Sabatini, F; Stabile, A; Berra, A; Giachero, A; Gotti, C; Lietti, D; Maino, M; Pessina, G; Prest, M; Martin, J -P; Simard, M; Starinski, N; Taras, P; Drutskoy, A; Makarychev, S; Nefediev, A V; Aloisio, A; Cavaliere, S; De Nardo, G; Della Pietra, M; Doria, A; Giordano, R; Ordine, A; Pardi, S; Russo, G; Sciacca, C; Bigi, I I; Jessop, C P; Wang, W; Bellato, M; Benettoni, M; Corvo, M; Crescente, A; Corso, F Dal; Dosselli, U; Fanin, C; Gianelle, A; Longo, S; Michelotto, M; Montecassiano, F; Morandin, M; Pengo, R; Posocco, M; Rotondo, M; Simi, G; Stroili, R; Gaioni, L; Manazza, A; Manghisoni, M; Ratti, L; Re, V; Traversi, G; Zucca, S; Bizzaglia, S; Bizzarri, M; Cecchi, C; Germani, S; Lebeau, M; Lubrano, P; Manoni, E; Papi, A; Rossi, A; Scolieri, G; Batignani, G; Bettarini, S; Casarosa, G; Cervelli, A; Fella, A; Forti, F; Giorgi, M; Lilli, L; Lusiani, A; Oberhof, B; Paladino, A; Pantaleo, F; Paoloni, E; Perez, A L Perez; Rizzo, G; Walsh, J; Téllez, A Fernández; Beck, G; Berman, M; Bevan, A; Gannaway, F; Inguglia, G; Martin, A J; Morris, J; Bocci, V; Capodiferro, M; Chiodi, G; Dafinei, I; Drenska, N V; Faccini, R; Ferroni, F; Gargiulo, C; Gauzzi, P; Luci, C; Lunadei, R; Martellotti, G; Pellegrino, F; Pettinacci, V; Pinci, D; Recchia, L; Ruggeri, D; Zullo, A; Camarri, P; Cardarelli, R; De Santis, C; Di Ciaccio, A; Di Felice, V; Di Palma, F; Di Simone, A; Marcelli, L; Messi, R; Moricciani, D; Sparvoli, R; Tammaro, S; Branchini, P; Budano, A; Bussino, S; Ciuchini, M; Nguyen, F; Passeri, A; Ruggieri, F; Spiriti, E; Wilson, F; Monzon, I Leon; Millan-Almaraz, J R; Podesta-Lerma, P L M; Aston, D; Dey, B; Fisher, A; Jackson, P D; Leith, D W G S; Luitz, S; MacFarlane, D; McCulloch, M; Metcalfe, S; Novokhatski, A; Osier, S; Prepost, R; Ratcliff, B; Seeman, J; Sullivan, M; Va'vra, J; Wienands, U; Wisniewski, W; Altschul, B D; Purohit, M V; Baudot, J; Ripp-Baudot, I; Cirrone, G A P; Cuttone, G; Bezshyyko, O; Dolinska, G; Soffer, A; Bianchi, F; De Mori, F; Filippi, A; Gamba, D; Marcello, S; Bomben, M; Bosisio, L; Cristaudo, P; Lanceri, L; Liberti, B; Rashevskaya, I; Stella, C; Vallazza, E S; Vitale, L; Auriemma, G; Satriano, C; Vidal, F Martinez; de Cos, J Mazorra; Oyanguren, A; Valls, P Ruiz; Beaulieu, A; Dejong, S; Franta, J; Lewczuk, M J; Roney, M; Sobie, R

    2013-01-01

    In this Technical Design Report (TDR) we describe the SuperB detector that was to be installed on the SuperB e+e- high luminosity collider. The SuperB asymmetric collider, which was to be constructed on the Tor Vergata campus near the INFN Frascati National Laboratory, was designed to operate both at the Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1} and at the tau/charm production threshold with a luminosity of 10^{35} cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100 larger than present B Factories, would allow investigation of new physics effects in rare decays, CP Violation and Lepton Flavour Violation. This document details the detector design presented in the Conceptual Design Report (CDR) in 2007. The R&D and engineering studies performed to arrive at the full detector design are described, and an updated cost estimate is presented. A combination of a more realistic cost estimates and the unavailability of funds due of the global economic ...

  18. Design of a large dynamics fast acquisition device: application to readout of the electromagnetic calorimeter in the ATLAS experiment

    International Nuclear Information System (INIS)

    The construction of the new particle accelerator, the LHC (Large Hadron Collider) at CERN is entails many research and development projects. It is the case in electronics where the problem of the acquisition of large dynamic range signals at high sampling frequencies occurs. Typically, the requirements are a dynamic range of about 65,000 (around 16 bits) at 40 MHz. Some solutions to this problem will be presented. One of them is using a commercial analog-to-digital converter. This case brings up the necessity of a signal conditioning equipment. This thesis describes a way of building such a system that will be called 'multi-gain system'. Then, an application of this method is presented. It involves the realization of an automatic gain switching integrated circuit. It is designed for the readout of the ATLAS electromagnetic calorimeter. The choice and the calculation of the components of this systems are described. They are followed by the results of some measurements done on a prototype made using the AMS 1.2μm BiCMOS foundry. Possible enhancements are also presented. We conclude on the feasibility of such a system and its various applications in a number of fields that are not restricted to particle physics. (author)

  19. ATLAS-Hadronic Calorimeter

    CERN Multimedia

    2003-01-01

    Hall 180 work on Hadronic Calorimeter The ATLAS hadronic tile calorimeter The Tile Calorimeter, which constitutes the central section of the ATLAS hadronic calorimeter, is a non-compensating sampling device made of iron and scintillating tiles. (IEEE Trans. Nucl. Sci. 53 (2006) 1275-81)

  20. Design of a new front-end electronics test-bench for the upgraded ATLAS detector's Tile Calorimeter

    Science.gov (United States)

    Kureba, C. O.; Govender, M.; Hofsajer, I.; Ruan, X.; Sandrock, C.; Spoor, M.

    2015-10-01

    The year 2022 has been scheduled to see an upgrade of the Large Hadron Collider (LHC), in order to increase its instantaneous luminosity. The High Luminosity LHC, also referred to as the upgrade Phase-II, means an inevitable complete re-design of the read-out electronics in the Tile Calorimeter (TileCal) of the A Toroidal LHC Apparatus (ATLAS) detector. Here, the new read-out architecture is expected to have the front-end electronics transmit fully digitized information of the detector to the back-end electronics system. Fully digitized signals will allow more sophisticated reconstruction algorithms which will contribute to the required improved triggers at high pile-up. In Phase II, the current Mobile Drawer Integrity ChecKing (MobiDICK) test-bench will be replaced by the next generation test-bench for the TileCal superdrawers, the new Prometeo (A Portable ReadOut ModulE for Tilecal ElectrOnics). Prometeo is a portable, high-throughput electronic system for full certification of the front-end electronics of the ATLAS TileCal. It is designed to interface to the fast links and perform a series of tests on the data to assess the certification of the electronics. The Prometeo's prototype is being assembled by the University of the Witwatersrand and installed at CERN for further developing, tuning and tests. This article describes the overall design of the new Prometeo, and how it fits into the TileCal electronics upgrade.

  1. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Heelan, Louise; The ATLAS collaboration

    2015-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. It is also useful for identification and reconstruction of muons due to good signal to noise ratio. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 5000 cells, each viewed by two photomultipliers. The calorimeter response and its readout electronics is monitored to better than 1% using radioactive source, laser and charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of proton-proton collisions acquired in 2011 and 2012. Results on the calorimeter performance are presented, including the absolute energy scale, timing, noise and associated stabilities. The results demonstrate that the Tile Calorimeter has performed well within the design ...

  2. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Solodkov, Alexander; The ATLAS collaboration

    2015-01-01

    The Tile Calorimeter (TileCal), the central section of the hadronic calorimeter of the ATLAS experiment, is a key detector component to detect hadrons, jets and taus and to measure the missing transverse energy. Due to the very good muon signal to noise ratio it assists the spectrometer in the identification and reconstruction of muons. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 5182 cells, each viewed by two photomultipliers. The calorimeter response and its readout electronics is monitored to better than 1\\% using radioactive source, laser and charge injection systems. The performance of the calorimeter has been measured and monitored using calibration data, cosmic ray muons and the large sample of proton-proton collisions acquired in 2011 and 2012. The results demonstrate a very good understanding of the performance of the Tile Calorimeter that is well within the design expectations.

  3. Design of a photodetector unit of a new Shashlyk EM calorimeter for COMPASS II

    International Nuclear Information System (INIS)

    A nine-channel photodetector unit with micropixel avalanche photodiodes (MAPD) and precision thermostabilization based on the compact Peltier module was designed and constructed. MAPD-3N with a high pixel density of 1.5·104 mm-2 and area 3x3 mm produced by Zecotek were used.

  4. Design and operating experience with electric systems for high rate liquid argon calorimeters

    International Nuclear Information System (INIS)

    A number of experiments have been instrumented by an ADC scheme utilizing an integrated amplifier, a packaged delay line, the difference of two samples taken Before and After the signal exits the delay, and a multiplexer to a single ADC for a system. Design features, operating peculiarities, and experience to date are discussed

  5. International Linear Collider Technical Design Report (Volumes 1 through 4)

    Energy Technology Data Exchange (ETDEWEB)

    Harrison M.

    2013-03-27

    The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.

  6. ELECTRONICS FOR CALORIMETERS AT LHC.

    Energy Technology Data Exchange (ETDEWEB)

    RADEKA,V.

    2001-09-11

    Some principal design features of front-end electronics for calorimeters in experiments at the LHC will be highlighted. Some concerns arising in the transition from the research and development and design phase to the construction will be discussed. Future challenges will be indicated.

  7. ELECTRONICS FOR CALORIMETERS AT LHC

    International Nuclear Information System (INIS)

    Some principal design features of front-end electronics for calorimeters in experiments at the LHC will be highlighted. Some concerns arising in the transition from the research and development and design phase to the construction will be discussed. Future challenges will be indicated

  8. The Prism Plastic Calorimeter (PPC)

    CERN Multimedia

    2002-01-01

    This proposal supports two goals: \\\\ \\\\ First goal:~~Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter~(PPC) towers with a new ``liquid crystal'' type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. \\\\ \\\\ Second goal:~~Describe how one can design a warm liquid calorimeter integrated into a LHC detector and to list the advantages of the PPC: low price, minimum of mechanical structures, minimum of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronic being outside of the liquid and easily accessible, one has maximum flexibility to define them. \\\\ \\\\ The R&D program, we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  9. Pion correlations and calorimeter design for high energy heavy ion collisions. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, K.L.

    1997-04-01

    Data analysis is in progress for recent experiments performed by the NA44 collaboration with the first running of 160 A GeV {sup 208}Pb-induced reactions at the CERN SPS. Identified singles spectra were taken for pions, kaons, protons, deuterons, antiprotons and antideuterons. Two-pion interferometry measurements were made for semi-central-triggered {sup 208}Pb + Pb collisions. An updated multi-particle spectrometer allows high statistics data sets of identified particles to be collected near mid-rapidity. A second series of experiments will be performed in the fall of 1995 with more emphasis on identical kaon interferometry and on the measurement of rare particle spectra and correlations. Modest instrumentation upgrades by TAMU are designed to increase the trigger function for better impact parameter selection and improved collection efficiency of valid events. An effort to achieve the highest degree of projectile-target stopping is outlined and it is argued that an excitation function on the SPS is needed to better understand reaction mechanisms. Analysis of experimental results is in the final stages at LBL in the EOS collaboration for two-pion interferometry in the 1.2 A GeV Au + Au reaction, taken with full event characterization.

  10. A Silicon Hadron Calorimeter Module Operated in a Strong Magnetic Field with VLSI Readout for LHC

    CERN Multimedia

    2002-01-01

    % RD35 \\\\ \\\\ On the basis of a cost optimized Silicon production technology we proposed to build a hadron calorimeter active plane. \\\\ \\\\The production of detectors is closely followed and final quality control is performed according to specifications. \\\\ \\\\The technology designed for the cheap pad detector production is applied for the coarse strip detector manufacturing. These strip detectors will be used in the preshower of the electromagnetic calorimeter of CMS. \\footnote{Research & Prod. Assoc. ELMA, RSFSR} \\footnote{Byelorussian State Univ. Minsk} \\footnote{Research & Prod. Comp. SIAPS, RSFSR} \\footnote{Joffe Physical-Technical Inst. RSFSR} \\footnote{Ansaldo Richerche spa, Genoa} \\footnote{SGS-THOMSON, Castelletto, Milan}

  11. Designing Technical Reports: Writing for Audiences in Organizations.

    Science.gov (United States)

    Mathes, J. C.; Stevenson, Dwight W.

    This book, written for engineering students and young practicing engineers, provides a systematic approach to the design of technical communication: the communication process, audience analysis, and the design and writing of technical reports. Focus is on the questions that a writer must answer in order to compose clear and effective reports: who…

  12. WAYS to study and research urban, architectural and technical design

    NARCIS (Netherlands)

    De Jonge, T.M.; Van der Voordt, D.J.M.

    2002-01-01

    This methodological book describes eight forms of study and research as they relate to design: 1) naming and describing; 2) design research and typology; 3) evaluating; 4) modelling; 5) programming and optimising; 6) technical study; 7) design study; 8) study by design. It includes the views, design

  13. The CDF miniplug calorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Lami, Stefano

    2002-06-28

    Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the (forward) pseudorapidity region of 3.6 < |{nu}| < 5.2 of the CDF detector, have been recently installed as part of the Run II CDF upgrade at the Tevatron {bar p}p collider. They consist of lead/liquid scintillator read out by wavelength shifting fibers arranged in a pixel-type towerless geometry suitable for ''calorimetric tracking''. The design concept, the prototype performance and the final design of the MiniPlugs are here described. A recent cosmic ray test resulted in a light yield of approximately 100 pe/MIP, which exceeds our design requirements.

  14. The CMS central hadron calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, J.; E892 Collaboration

    1996-12-31

    The CMS central hadron calorimeter is a copper absorber/ scintillator sampling structure. We describe design choices that led us to this concept, details of the mechanical and optical structure, and test beam results. We discuss calibration techniques, and finally the anticipated construction schedule.

  15. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Solodkov, Alexander; The ATLAS collaboration

    2015-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. It is also useful for identification and reconstruction of muons due to good signal to noise ratio. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 5000 cells, each viewed by two photomultipliers. The calorimeter response and its readout electronics is monitored to better than 1% using radioactive source, laser and charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of muons and single hadrons from proton-proton collisions acquired in 2011 and 2012. The results demonstrate that the Tile Calorimeter has performed well within the design requirements and it has given essential contribution to reconstructed objects and physics results.

  16. Mitigation of calorimeter noise.

    Energy Technology Data Exchange (ETDEWEB)

    Santi, P. A. (Peter A.); Bracken, D. S. (David S.); Smith, M. K. (Morag K.)

    2004-01-01

    One of the main factors that limit the sensitivity of calorimeters is the noise in the calorimeter response. A previous study into the sources of noise in a Wheatstone bridge calorimeter used by Department of Energy (DOE) facilities has shown that the control system for maintaining the water bath at a constant temperature was an important contributor to the noise in the system. In order to minimize the contribution that the control system makes to the noise in the calorimeter response, a new control system for the calorimeter has been developed. An experimental and analytical study has been performed to determine the effectiveness of this new control system in reducing the response noise in a Wheatstone bridge calorimeter. The results of this study are presented along with their implications for future work in minimizing the equilibrium noise of calorimeters.

  17. Study of a novel electromagnetic liquid argon calorimeter TGT

    International Nuclear Information System (INIS)

    The concept and the basic design of a fast, highly granular and compact electromagnetic liquid argon calorimeter are described. This novel calorimeter offers uniform energy response and constant energy resolution independent of the production angle of an impinging particle and of its impact position at the calorimeter. An example of a calorimeter with full rapidity coverage in an application in a collider detector is given. An important aspect of the concept is the electronics for fast signal processing matched to the short charge collection time. We report on the experience with the realization of a prototype calorimeter module and on its performance in a test beam exposure. 15 refs., 16 figs., 2 tabs

  18. Plan and Design Meticulously and Promoting Technical Progress

    Institute of Scientific and Technical Information of China (English)

    Miao Chengwu

    1994-01-01

    @@ Plan and design is the key link in captial construction, and the soul of engineering construction. China Petroleum Planning & Engineering Institute (CPPEI) is one of the main undertakers for planning and designing of petroleum industry,the only leading multi-functional institute with the first class design certificate. Now it has been an organization under the China National Petroleum Corporation(CNPC)for making development strategy planning, project evaluations and technical consulting, drawing up project development plan and providing technical recommendations. It can complete plan and design for the oil and gas field facilities, pipeline construction,petroleum relinery and petro-chemical industry engineering at home and abroad. It is also a center of servicing for new technical development and scientific research. Since CPPEI was established in 1978,it has meticulously conducted on planning and designing for the technical progress of petroleum engineering.

  19. The CALICE Tile Hadron Calorimeter Prototype With SiPM Readout: Design, Construction and First Test Beam Results

    CERN Document Server

    Wattimena, N

    2008-01-01

    The CALICE collaboration has constructed a test beam hadronic calorimeter (HCAL) with 7608 scintillator tiles, individually read out by novel multi-pixel Geiger mode photodiodes, so called SiPMs, and tested it in electron and hadron beams at CERN. This prototype is the first device which uses SiPMs on a large scale; its purpose is to establish the technology and to record hadron shower data with unprecedented granularity for the validation of simulation models and the development of clustering algorithms.

  20. Design of an FPGA-based embedded system for the ATLAS Tile Calorimeter front-end electronics test-bench

    International Nuclear Information System (INIS)

    The portable test-bench for the certification of the ATLAS tile hadronic calorimeter front-end electronics has been redesigned for the present Long Shutdown (LS1) of LHC, improving its portability and expanding its functionalities. This paper presents a new test-bench based on a Xilinx Virtex-5 FPGA that implements an embedded system using a PowerPC 440 microprocessor hard core and custom IP cores. A light Linux version runs on the PowerPC microprocessor and handles the IP cores which implement the different functionalities needed to perform the desired tests such as TTCvi emulation, G-Link decoding, ADC control and data reception

  1. UXO Engineering Design. Technical Specification and ConceptualDesign

    Energy Technology Data Exchange (ETDEWEB)

    Beche, J-F.; Doolittle, L.; Greer, J.; Lafever, R.; Radding, Z.; Ratti, A.; Yaver, H.; Zimmermann, S.

    2005-04-23

    The design and fabrication of the UXO detector has numerous challenges and is an important component to the success of this study. This section describes the overall engineering approach, as well as some of the technical details that brought us to the present design. In general, an array of sensor coils is measuring the signal generated by the UXO object in response to a stimulation provided by the driver coil. The information related to the location, shape and properties of the object is derived from the analysis of the measured data. Each sensor coil is instrumented with a waveform digitizer operating at a nominal digitization rate of 100 kSamples per second. The sensor coils record both the large transient pulse of the driver coil and the UXO object response pulse. The latter is smaller in amplitude and must be extracted from the large transient signal. The resolution required is 16 bits over a dynamic range of at least 140 dB. The useful signal bandwidth of the application extends from DC to 40 kHz. The low distortion of each component is crucial in order to maintain an excellent linearity over the full dynamic range and to minimize the calibration procedure. The electronics must be made as compact as possible so that the response of its metallic parts has a minimum signature response. Also because of a field system portability requirement, the power consumption of the instrument must be kept as low as possible. The theory and results of numerical and experimental studies that led to the proof-of-principle multitransmitter-multireceiver Active ElectroMagnetic (AEM) system, that can not only accurately detect but also characterize and discriminate UXO targets, are summarized in LBNL report-53962: ''Detection and Classification of Buried Metallic Objects, UX-1225''.

  2. Large capacity water and air bath calorimeters

    International Nuclear Information System (INIS)

    EG and G Mound Applied Technologies has developed an 11 in. x 17 in. sample size water bath and an 11 in. x 17 in. sample size air bath calorimeter which both function under servo control mode of operation. The water bath calorimeter has four air bath preconditioners to increase sample throughput and the air bath calorimeter has two air bath preconditioners. The large capacity calorimeters and preconditioners were unique to Mound design which brought about unique design challenges. Both large capacity systems calculate the optimum set temperature for each preconditioner which is available to the operator. Each system is controlled by a personal computer under DOS which allows the operator to download data to commercial software packages when the calorimeter is idle. Qualification testing yielded a one standard deviation of 0.6% for 0.2W to 3.0W Pu-238 heat standard range in the water bath calorimeter and a one standard deviation of 0.3% for the 6.0W to 20.0W Pu-238 heat standard range in the air bath calorimeter

  3. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    All the HCAL calorimeters are ready for data-taking in 2011 and participated fully in the cosmic running and initial beam operations in the last few weeks. Several improvements were made during the winter technical stop, including replacement of the light-guide sleeves in HF, improvements to the low voltage power connections, and separation of HF from HB and HE in the DAQ partitions. During the 2010 running a form of anomalous noise in the HF was identified as being caused by scintillation when charged particles pass through a portion of the air light-guide sleeve. This portion was constructed from a non-conductive mirror-like material called “HEM”. To suppress these anomalous signals, during the recent winter technical stop all sleeves in the detector were replaced with sleeves made of Tyvek. The detector has been recommissioned with all channels fully operational. Recalibration of the detector will be required due to the differing reflectivity of the new sleeves compared with the HEM sl...

  4. CDF End Plug calorimeter Upgrade Project

    International Nuclear Information System (INIS)

    We report on the status of the CDF End Plug Upgrade Project. In this project, the CDF calorimeters in the end plug and the forward regions will be replaced by a single scintillator based calorimeter. After an extensive R ampersand D effort on the tile/fiber calorimetry, we have now advanced to a construction phase. We review the results of the R ampersand D leading to the final design of the calorimeters and the development of tooling devised for this project. The quality control program of the production of the electromagnetic and hadronic calorimeters is described. A shower maximum detector for the measurement of the shower centroid and the shower profile of electrons, γ and π0 has been designed. Its performance requirements, R ampersand D results and mechanical design are discussed

  5. The ATLAS Forward Calorimeter

    Science.gov (United States)

    Artamonov, A.; Bailey, D.; Belanger, G.; Cadabeschi, M.; Chen, T.-Y.; Epshteyn, V.; Gorbounov, P.; Joo, K. K.; Khakzad, M.; Khovanskiy, V.; Krieger, P.; Loch, P.; Mayer, J.; Neuheimer, E.; Oakham, F. G.; O'Neill, M.; Orr, R. S.; Qi, M.; Rutherfoord, J.; Savine, A.; Schram, M.; Shatalov, P.; Shaver, L.; Shupe, M.; Stairs, G.; Strickland, V.; Tompkins, D.; Tsukerman, I.; Vincent, K.

    2008-02-01

    Forward calorimeters, located near the incident beams, complete the nearly 4π coverage for high pT particles resulting from proton-proton collisions in the ATLAS detector at the Large Hadron Collider at CERN. Both the technology and the deployment of the forward calorimeters in ATLAS are novel. The liquid argon rod/tube electrode structure for the forward calorimeters was invented specifically for applications in high rate environments. The placement of the forward calorimeters adjacent to the other calorimeters relatively close to the interaction point provides several advantages including nearly seamless calorimetry and natural shielding for the muon system. The forward calorimeter performance requirements are driven by events with missing ET and tagging jets.

  6. A calorimeter with array detectors

    International Nuclear Information System (INIS)

    A 5 x 25 = 125 detector array has been designed for a calorimeter. Each element is consisted of a graphite block and a chromel-alumel. A new '0'-point set up was designed by using the critical temperature of the liquid nitrogen as the '0'-point of the temperature. A FY-1 data acquisition system was used for the detector array. The energy distribution of the electron beam has been measured on large-area diode with the system

  7. The Lund–York–Cologne Calorimeter (LYCCA): Concept, design and prototype developments for a FAIR-NUSTAR detector system to discriminate relativistic heavy-ion reaction products

    International Nuclear Information System (INIS)

    The concept, design and prototype developments for the Lund–York–Cologne CAlorimeter (LYCCA) is presented. LYCCA is a modular device for the NUclear STructure, Astrophysics and Reactions (NUSTAR) science pillar of the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. LYCCA is designed to discriminate heavy ions produced in nuclear reactions induced by relativistic radioactive ion beams. Measurements of energy loss, total energy, and time-of-flight allow the derivation of proton number, Z, and mass number, A, of the reaction products. LYCCA-inherent tracking of the flight paths of the reaction products enables coincident HIgh-resolution in-beam γ-ray SPECtroscopy (HISPEC) of atomic nuclei far from the line of β-stability

  8. WAYS to study and research urban, architectural and technical design

    OpenAIRE

    De Jonge, T.M.; Van der Voordt, D.J.M.

    2002-01-01

    This methodological book describes eight forms of study and research as they relate to design: 1) naming and describing; 2) design research and typology; 3) evaluating; 4) modelling; 5) programming and optimising; 6) technical study; 7) design study; 8) study by design. It includes the views, design related research projects and research methods being applied by over 40 different authors, all working at the Faculty of Architecture of the Delft University of Technology. As such this overwhelim...

  9. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    Bartos, Pavol; The ATLAS collaboration

    2016-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted to photomultiplier tubes (PMTs). Signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. Results on the calorimeter operation and performance are presented, including the calibration, stability, absolute energy scale, uniformity and time resolution. These results show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.

  10. The KLOE electromagnetic calorimeter

    International Nuclear Information System (INIS)

    A general purpose detector, KLOE, is under construction for operations at the Frascati φ factory, DAΦNE. Its central mission is the study of direct CP violation in K0 decays, which places very stringent requirements on electromagnetic shower measurements in the 20-280 MeV/c region. We have chosen to use a lead-scintillator sampling calorimeter, EmC, consisting of very thin (0.5 mm) lead layers in which are embedded 1 mm diameter scintillating fibers. Much prototyping and testing has been done during its design, yielding, for the final EmC, an expected energy resolution of σ(E)/E similar 4.4%/√(E(GeV)) and a time resolution of similar 46 ps/√(E(GeV)), with excellent linearity in the region of interest and with little dependence on incidence angle and entry position. (orig.)

  11. Single-Case Designs Technical Documentation

    Science.gov (United States)

    Kratochwill, T. R.; Hitchcock, J.; Horner, R. H.; Levin, J. R.; Odom, S. L.; Rindskopf, D. M; Shadish, W. R.

    2010-01-01

    In an effort to expand the pool of scientific evidence available for review, the What Works Clearinghouse (WWC) assembled a panel of national experts in single-case design (SCD) and analysis to draft SCD Standards. SCDs are adaptations of interrupted time-series designs and can provide a rigorous experimental evaluation of intervention effects.…

  12. Network design management and technical perspectives

    CERN Document Server

    Piliouras, Teresa C

    2004-01-01

    MAKING THE BUSINESS CASE FOR THE NETWORKManagement Overview of Network DesignDefine the Business ObjectivesDetermine Potential Risks, Dependencies, Costs andBenefitsIdentify Project RequirementsDevelop Project Implementation ApproachStrategic Positioning Using NetworksCase StudiesCalculation of Technology's Strategic ValueDealing with Major Design ChallengesOrganizational Concerns and RecommendationsTechnology Concerns and RecommendationsSimilarities and Differences between Voice and DataNetwork Design and PlanningMajor Trends and Technology EnablersSocietal TrendsService Provider TrendsMajor

  13. Time resolution of the SND electromagnetic calorimeter

    International Nuclear Information System (INIS)

    A new spectrometric channel of the SND electromagnetic calorimeter is described. It has a time resolution of about 1.3 ns at an energy deposition in the calorimeter crystal of 100 MeV and an amplitude resolution of about 250 keV. The new channel is designed, in particular, for the study of the e+e−→ n n-bar process at the VEPP-2000 e+e− collider

  14. Advance of the graphite-calorimeter primary standard

    International Nuclear Information System (INIS)

    The Austrian absorbed dose to water primary standardisation system is based on a graphite calorimeter. It was developed by BEV in cooperation with the Research Centers Seibersdorf and is in operation since 1983. The realisation of the unit absorbed dose to water is based upon absorbed dose to graphite measurements. The conversion from absorbed dose to graphite to absorbed dose to water is done by two methods based on the photon fluence scaling theorem. The graphite-calorimeter was originally designated for determination of absorbed dose to water in 60Co gamma ray beams. The progress in radiation therapy within the recent years required the extension of the primary standard application range to enable field characterisation and calibration of medical accelerators. In order to operate the energy range and application enhancement, a set of conversion and correction factors was needed. They were obtained via Monte Carlo simulations with PENELOPE-2006 code, and measurements - with the calorimeter itself and ionisation chambers. The accomplishment of the BEV high energy calorimetry project was promoted by the Physico-technical Testing Service (PTP), which is an entity of BEV. (orig.)

  15. LHCb calorimeter electronics. Photon identification. Calorimeter calibration

    International Nuclear Information System (INIS)

    LHCb is one of the four large experiments installed on the LHC accelerator ring. The aim of the detector is to precisely measure CP violation observables and rare decays in the B meson sector. The calorimeter system of LHCb is made of four sub-systems: the scintillating pad detector, the pre-shower, the electromagnetic (ECAL) and hadronic (HCAL) calorimeters. It is essential to reconstruct B decays, to efficiently trigger on interesting events and to identify electrons and photons. After a review of the LHCb detector sub-systems, the first part of this document describes the calorimeter electronics. First, the front-end electronics in charge of measuring the ECAL and HCAL signals from the photomultipliers is presented, then the following section is an overview of the control card of the four calorimeters. The chapters three and four concern the test software of this electronics and the technological choices making it tolerant to radiations in the LHCb cavern environment. The measurements performed to ensure this tolerance are also given. The second part of this document concerns both the identification of the photons with LHCb and the calibration of the calorimeters. The photon identification method is presented and the performances given. Finally, the absolute energy calibration of the PRS and ECAL, based on the data stored in 2010 is explained. (author)

  16. Technical report on LWR design decision methodology. Phase I

    International Nuclear Information System (INIS)

    Energy Incorporated (EI) was selected by Sandia Laboratories to develop and test on LWR design decision methodology. Contract Number 42-4229 provided funding for Phase I of this work. This technical report on LWR design decision methodology documents the activities performed under that contract. Phase I was a short-term effort to thoroughly review the curret LWR design decision process to assure complete understanding of current practices and to establish a well defined interface for development of initial quantitative design guidelines

  17. Technical basis for the ITER-FEAT outline design

    International Nuclear Information System (INIS)

    This ITER EDA Documentation Series issue summarizes the results of the ITER Engineering Design Activities on the technical basis for the ITER-FEAT outline design. This issue also comprises some physical analysis activities as well as structure and goals of the Physics Expert Group activities

  18. Technical Design Report for the: PANDA Micro Vertex Detector

    CERN Document Server

    Erni, W; Krusche, B; Steinacher, M; Heng, Y; Liu, Z; Liu, H; Shen, X; Wang, Q; Xu, H; Albrecht, M; Becker, J; Eickel, K; Feldbauer, F; Fink, M; Friedel, P; Heinsius, F H; Held, T; Koch, H; Kopf, B; Leyhe, M; Motzko, C; Pelizäus, M; Pychy, J; Roth, B; Schröder, T; Schulze, J; Steinke, M; Trifterer, T; Wiedner, U; Zhong, J; Beck, R; Becker, M; Bianco, S; Brinkmann, K -Th; Hammann, C; Hinterberger, F; Jäkel, R; Kaiser, D; Kliemt, R; Koop, K; Schmidt, C; Schnell, R; Thoma, U; Vlasov, P; Wendel, C; Winnebeck, A; Würschig, Th; Zaunick, H -G; Bianconi, A; Bragadireanu, M; Caprini, M; Ciubancan, M; Pantea, D; Tarta, P -D; De Napoli, M; Giacoppo, F; Rapisarda, E; Sfienti, C; Fiutowski, T; Idzik, N; Mindur, B; Przyborowski, D; Swientek, K; Bialkowski, E; Budzanowski, A; Czech, B; Kliczewski, S; Kozela, A; Kulessa, P; Lebiedowicz, P; Malgorzata, K; Pysz, K; Schäfer, W; Siudak, R; Szczurek, A; Brandys, P; Czyzewski, T; Czyzycki, W; Domagala, M; Hawryluk, M; Filo, G; Kwiatkowski, D; Lisowski, E; Lisowski, F; Bardan, W; Gil, D; Kamys, B; Kistryn, St; Korcyl, K; Krzemieñ, W; Magiera, A; Moskal, P; Rudy, Z; Salabura, P; Smyrski, J; Wroñska, A; Al-Turany, M; Arora, R; Augustin, I; Deppe, H; Dutta, D; Flemming, H; Götzen, K; Hohler, G; Karabowicz, R; Lehmann, D; Lewandowski, B; Lühning, J; Maas, F; Orth, H; Peters, K; Saito, T; Schepers, G; Schmidt, C J; Schmitt, L; Schwarz, C; Schwiening, J; Voss, B; Wieczorek, P; Wilms, A; Abazov, V M; Alexeev, G D; Arefiev, V A; Astakhov, V I; Barabanov, M Yu; Batyunya, B V; Davydov, Yu I; Dodokhov, V Kh; Efremov, A A; Fedunov, A G; Feshchenko, A A; Galoyan, A S; Grigoryan, S; Karmokov, A; Koshurnikov, E K; Lobanov, V I; Lobanov, Yu Yu; Makarov, A F; Malinina, L V; Malyshev, V L; Mustafaev, G A; Olshevski, A G; Pasyuk, M A; Perevalova, E A; Piskun, A A; Pocheptsov, T A; Pontecorvo, G; Rodionov, V K; Rogov, Yu N; Salmin, R A; Samartsev, A G; Sapozhnikov, M G; Shabratova, G S; Skachkova, A N; Skachkov, N B; Strokovsky, E A; Suleimanov, M K; Teshev, R Sh; Tokmenin, V V; Uzhinsky, V V; Vodopyanov, A S; Zaporozhets, S A; Zhuravlev, N I; Zorin, A G; Branford, D; Glazier, D; Watts, D; Woods, P; Britting, A; Eyrich, W; Lehmann, A; Uhlig, F; Dobbs, S; Metreveli, Z; Seth, K; Tann, B; Tomaradze, A; Bettoni, D; Carassiti, V; Dalpiaz, P; Drago, A; Fioravanti, E; Garzia, I; Negrini, M; Savriè, M; Stancari, G; Dulach, B; Gianotti, P; Guaraldo, C; Lucherini, V; Pace, E; Bersani, A; Macri, M; Marinelli, M; Parodi, R F; Dormenev, V; Drexler, P; Düren, M; Eisner, T; Foehl, K; Hayrapetyan, A; Koch, P; Krïoch, B; Kühn, W; Lange, S; Liang, Y; Liu, M; Merle, O; Metag, V; Moritz, M; Nanova, M; Novotny, R; Spruck, B; Stenzel, H; Strackbein, C; Thiel, M; Wang, Q; Clarkson, T; Euan, C; Hill, G; Hoek, M; Ireland, D; Kaiser, R; Keri, T; Lehmann, I; Livingston, K; Lumsden, P; MacGregor, D; McKinnon, B; Montgomery, R; Murray, M; Protopopescu, D; Rosner, G; Seitz, B; Yang, G; Babai, M; Biegun, A K; Glazenborg-Kluttig, A; Guliyev, E; Jothi, V S; Kavatsyuk, M; Lemmens, P; Löhner, H; Messchendorp, J; Poelman, T; Smit, H; van der Weele, J C; Sohlbach, H; Büscher, M; Dosdall, R; Dzhygadlo, R; Esch, S; Gillitzer, A; Goldenbaum, F; Grunwald, D; Jha, V; Kemmerling, G; Kleines, H; Lehrach, A; Maier, R; Mertens, M; Ohm, H; Pohl, D L; Prasuhn, D; Randriamalala, T; Ritman, J; Roeder, M; Sterzenbach, G; Stockmanns, T; Wintz, P; Wüstner, P; Xu, H; Kisiel, J; Li, S; Li, Z; Sun, Z; Xu, H; Fissum, K; Hansen, K; Isaksson, L; Lundin, M; Schröder, B; Achenbach, P; Denig, A; Distler, M; Fritsch, M; Kangh, D; Karavdina, A; Lauth, W; Michel, M; Espi, M C Mora; Pochodzalla, J; Sanchez, S; Sanchez-Lorente, A; Sfienti, C; Weber, T; Dormenev, V I; Fedorov, A A; Korzhik, M V; Missevitch, O V; Boukharov, A; Malyshev, O; Marishev, I; Semenov, A; Varma, R; Höppner, C; Ketzer, B; Konorov, I; Mann, A; Neubert, S; Paul, S; Vandenbroucke, M; Zhang, Q; Khoukaz, A; Rausmann, T; Täschner, A; Wessels, J; Baldin, E; Kotov, K; Peleganchuk, S; Tikhonov, Yu; Hennino, T; Imre, M; Kunne, R; Galliard, C Le; Normand, J P Le; Marchand, D; Maroni, A; Ong, S; Pouthas, J; Ramstein, B; Rosier, P; Sudol, M; Theneau, C; Tomasi-Gustafsson, E; Van de Wiele, J; Zerguerras, T; Boca, G; Braghieri, A; Costanza, S; Fontana, A; Genova, P; Lavezzi, L; Montagna, P; Rotondi, A; Buda, V; Abramov, V V; Davidenko, A M; Derevschikov, A A; Goncharenko, Y M; Grishin, V N; Kachanov, V A; Konstantinov, D A; Kormilitsin, V A; Matulenko, Y A; Melnik, Y M; Meschanin, A P; Minaev, N G; Mochalov, V V; Morozov, D A; Nogach, L V; Nurushev, S B; Ryazantsev, A V; Semenov, P A; Soloviev, L F; Uzunian, A V; Vasiliev, A N; Yakutin, A E; Belostotski, S; Gavrilov, G; Itzotov, A; Kisselev, A; Kravchenko, P; Manaenkov, S; Miklukho, O; Naryshkin, Y; Veretennikov, D; Vikhrov, V; Zhadanov, A; Bäck, T; Cederwall, B; Bargholtz, C; Gerén, L; Tegnér, P E; Thørngren, P; von Würtemberg, K M; Fava, L; Alberto, D; Amoroso, A; Bussa, M P; Busso, L; De Mori, F; Destefanis, M; Ferrero, L; Greco, M; Kugathasan, T; Maggiora, M; Marcello, S; Sosio, S; Spataro, S; Calvo, D; Coli, S; De Remigis, P; Filippi, A; Giraudo, G; Lusso, S; Mazza, G; Mignone, M; Rivetti, A; Wheadon, R; Zotti, L; Morra, O; Iazzi, F; Lavagno, A; Quarati, P; Szymanska, K; Birsa, R; Bradamante, F; Bressan, A; Martin, A; Clement, H; Galnander, B; Calén, H; Fransson, K; Johansson, T; Kupsc, A; Marciniewski, P; Thomé, E; Wolke, M; Zlomanczuk, J; Díaz, J; Ortiz, A; Buda, P; Dmowski, K; Korzeniewski, R; Przemyslaw, D; Slowinski, B; Borsuk, S; Chlopik, A; Guzik, Z; Kopec, J; Kozlowski, T; Melnychuk, D; Plominski, M; Szewinski, J; Traczyk, K; Zwieglinski, B; Bühler, P; Gruber, A; Kienle, P; Marton, J; Widmann, E; Zmeskal, J

    2012-01-01

    This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as close as possible to the interaction zone. Design criteria and the optimisation process as well as the technical solutions chosen are discussed and the results of this process are subjected to extensive Monte Carlo physics studies. The route towards realisation of the detector is outlined.

  19. Technical Design Report, Second Target Station

    Energy Technology Data Exchange (ETDEWEB)

    Galambos, John D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Anderson, David E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bechtol, D. [HDR, Inc., Chattanooga, TN (United States); Bethea, Katie L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Brown, N. [Barge Waggoner Sumner & Cannon, Inc., Nashville, TN (United States); Carden, W. F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Chae, Steven M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Clark, A. [Barge Waggoner Sumner & Cannon, Inc., Nashville, TN (United States); Counce, Deborah M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Craft, K. [Barge Waggoner Sumner & Cannon, Inc., Nashville, TN (United States); Crofford, Mark T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Collins, Richard M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cousineau, Sarah M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Curry, Douglas E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Cutler, Roy I. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dayton, Michael J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dean, Robert A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Deibele, Craig E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Doleans, Marc [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dye, T. [HDR, Inc., Chattanooga, TN (United States); Eason, Bob H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Eckroth, James A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Fincrock, C. [HDR, Inc., Chattanooga, TN (United States); Fritts, S. [Barge Waggoner Sumner & Cannon, Inc., Nashville, TN (United States); Gallmeier, Franz X. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gawne, Ken R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hartman, Steven M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Herwig, Kenneth W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hess, S. [HDR, Inc., Chattanooga, TN (United States); Holmes, Jeffrey A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Horak, Charlie M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Howell, Matthew P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Iverson, Erik B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jacobs, Lorelei L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jones, Larry C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Johnson, B. [HDR, Inc., Chattanooga, TN (United States); Johnson, S. [HDR, Inc., Chattanooga, TN (United States); Kasemir, Kay [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kim, Sang-Ho [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Laughon, Gregory J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lu, W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mahoney, Kelly L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Mammosser, John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McManamy, T. [McManamy Consulting, Inc., Knoxville, TN (United States); Michilini, M. [HDR, Inc., Chattanooga, TN (United States); Middendorf, Mark E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); O' Neal, Ed [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nemec, B. [Barge Waggoner Sumner & Cannon, Inc., Nashville, TN (United States); Peters, Roy Cecil [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Plum, Michael A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Reagan, G. [Barge Waggoner Sumner & Cannon, Inc., Nashville, TN (United States); Remec, Igor [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rennich, Mark J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Riemer, Bernie [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Saethre, Robert B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Schubert, James Phillip [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shishlo, Andrei P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smith, C. Craig [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Strong, William Herb [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Tallant, Kathie M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Tennant, David Alan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Thibadeau, Barbara M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Trumble, S. [HDR, Inc., Chattanooga, TN (United States); Trotter, Steven M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Z. [Institute of Modern Physics (IMP), Chinese Academy of Sciences (China); Webb, Steven B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Williams, Derrick C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); White, Karen S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Zhao, Jinkui [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    The Second Target Station (STS) is a proposed upgrade for SNS. It includes a doubling of the accelerator power and an additional instrument hall. The new instrument hall will receive a 467 kW 10 Hz beam. The parameters and preliminary design aspects of the STS are presented for the accelerator, target systems, instrument hall, instruments and civil construction aspects.

  20. AIDA: concerted calorimeter development

    CERN Multimedia

    Felix Sefkow

    2013-01-01

    AIDA – the EU-funded project bringing together more than 80 institutes worldwide – aims at developing new detector solutions for future accelerators. Among the highlights reported at AIDA’s recent annual meeting in Frascati was the completion of an impressive calorimeter test beam programme, conducted by the CALICE collaboration over the past two years at CERN’s PS and SPS beam lines.   The CALICE tungsten calorimeter prototype under test at CERN. This cubic-metre hadron calorimeter prototype has almost 500,000 individually read-out electronics channels – more than all the calorimeters of ATLAS and CMS put together. Calorimeter development in AIDA is mainly motivated by experiments at possible future electron-positron colliders, namely ILC or CLIC. The physics requirements of such future machines demand extremely high-performance calorimetry. This is best achieved using a finely segmented system that reconstructs events using the so-called pa...

  1. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding and A. Skuja

    2010-01-01

    Splash and Collision Data HCAL recorded the beam-on-collimator (splash) and the first collision data in November and December 2009, and provided triggers to CMS with the forward calorimeter, HF. Splash events were used to improve the energy inter-calibration of the HB and HE channels, with the basic assumption that the energy deposited in the detector by the large flux of muons that passed through in splash events was a smooth function in eta and phi. The new HB and HE calibration coefficients were applied prior to the collision data taking. For HO, a similar analysis is being finalized. Splash events were also used to determine the relative timing between channels in HB and HE, and new delay settings were calculated based on splashes from one beam, applied and verified with the splash events from the other beam. During Fall 2009, the HF technical trigger was improved in order to be effectively used as one of the main CMS triggers during the collision data taking. Collisions were successfully recorded by all...

  2. Overview of the LHCb Calorimeter Detectors

    CERN Document Server

    Perret, P

    2013-01-01

    The LHCb calorimeter system is composed of four subdetectors: an electromagnetic calorimeter (ECAL) followed by a hadron calorimeter (HCAL). In addition the system includes in front of them the Scintillating Pad Detector (SPD) and Pre-Shower (PS). It is used to select transverse energy hadron, electron and photon candidates for the first trigger level and it provides the identification of electrons, photons and hadrons as well as the measurement of their energies and positions. The design and construction characteristics of the LHCb calorimeter will be recalled. Strategies for monitoring and calibration during data taking will be detailed in all aspects. Scintillating fibres, plastics and photomultipliers suffer from ageing due to radiation damage or high currents. Different methods which are used to calibrate the detectors and to recover the initial performances will be presented. The performances achieved will be illustrated in selected channels of interest for B physics.

  3. Uranium scintillator calorimeter at the CERN ISR

    International Nuclear Information System (INIS)

    The design, Monte Carlo studies and test beam results of a uranium/scintillator calorimeter to be installed in the Intersecting Storage Ring (ISR) at CERN are described. In its final stage the calorimeter will cover the full azimuth over a polar region of 450 0. The full calorimeter is built in a modular way from 128 stacks, with each stack internally subdivided into six cells of 20 x 20 cm2 cross section. The readout is by wavelength shifting (WLS) plates with a separate readout of the front part of the calorimeter (first ten plates) to allow electromagnetic/hadronic separation. Since the readout plates are on both sides of the cells, position information is obtained from the left/right ratio

  4. Functional Planning and Design of a Fan Shaped Technical Museum

    Directory of Open Access Journals (Sweden)

    Dr. Lovely K M

    2014-04-01

    Full Text Available The proposed building aims at the development of the built environment. The principal objective of this paper is the functional planning, analysis and design of a fan shaped technical museum. Technical museum is a museum that tells the stories of architecture, engineering and design. The functional planning was done according to the clauses given by Museum Building Design and Exhibition Layout: Patterns of Interactions, ICOM Code of Ethics for Museum, and Key Concepts of Museology. Plan, elevation and section were drawn in AutoCAD 2010. The design involves load calculations and analyzing the whole structure by STAAD.ProV8i. The design methods used in STAAD.ProV8i analysis are limit state design conforming to Indian Standard Code of practice. Also the building was analyzed for all possible load combinations.

  5. Mu2e Technical Design Report

    CERN Document Server

    Bartoszek, L; Miller, J P; Mott, J; Palladino, A; Quirk, J; Roberts, B L; Crnkovic, J; Polychronakos, V; Tishchenko, V; Yamin, P; Cheng, C -h; Echenard, B; Flood, K; Hitlin, D G; Kim, J H; Miyashita, T S; Porter, F C; Röhrken, M; Trevor, J; Zhu, R -Y; Heckmaier, E; Kang, T I; Lim, G; Molzon, W; You, Z; Artikov, A M; Budagov, J A; Davydov, Yu I; Glagolev, V V; Simonenko, A V; Usubov, Z U; Oh, S H; Wang, C; Ambrosio, G; Andreev, N; Arnold, D; Ball, M; Bernstein, R H; Bianchi, A; Biery, K; Bossert, R; Bowden, M; Brandt, J; Brown, G; Brown, H; Buehler, M; Campbell, M; Cheban, S; Chen, M; Coghill, J; Coleman, R; Crowley, C; Deshpande, A; Deuerling, G; Dey, J; Dhanaraj, N; Dinnon, M; Dixon, S; Drendel, B; Eddy, N; Evans, R; Evbota, D; Fagan, J; Feher, S; Fellenz, B; Friedsam, H; Gallo, G; Gaponenko, A; Gardner, M; Gaugel, S; Genser, K; Ginther, G; Glass, H; Glenzinski, D; Hahn, D; Hansen, S; Hartsell, B; Hays, S; Hocker, J A; Huedem, E; Huffman, D; Ibrahim, A; Johnstone, C; Kashikhin, V; Kashikhin, V V; Kasper, P; Kiper, T; Knapp, D; Knoepfel, K; Kokoska, L; Kozlovsky, M; Krafczyk, G; Kramp, M; Krave, S; Krempetz, K; Kutschke, R K; Kwarciany, R; Lackowski, T; Lamm, M J; Larwill, M; Leavell, F; Leeb, D; Leveling, A; Lincoln, D; Logashenko, V; Lombardo, V; Lopes, M L; Makulski, A; Martinez, A; McArthur, D; McConologue, F; Michelotti, L; Mokhov, N; Morgan, J; Mukherjee, A; Murat, P; Nagaslaev, V; Neuffer, D V; Nicol, T; Niehoff, J; Nogiec, J; Olson, M; Orris, D; Ostojic, R; Page, T; Park, C; Peterson, T; Pilipenko, R; Pla-Dalmau, A; Poloubotko, V; Popovic, M; Prebys, E; Prieto, P; Pronskikh, V; Pushka, D; Rabehl, R; Ray, R E; Rechenmacher, R; Rivera, R; Robotham, W; Rubinov, P; Rusu, V L; Scarpine, V; Schappert, W; Schoo, D; Stefanik, A; Still, D; Tang, Z; Tanovic, N; Tartaglia, M; Tassotto, G; Tinsley, D; Tschirhart, R S; Vogel, G; Wagner, R; Wands, R; Wang, M; Werkema, S; White, H B; Whitmore, J; Wielgos, R; Woods, R; Worel, C; Zifko, R; Ciambrone, P; Colao, F; Cordelli, M; Corradi, G; Dane, E; Giovannella, S; Happacher, F; Luca, A; Miscetti, S; Ponzio, B; Pileggi, G; Saputi, A; Sarra, I; Soleti, R S; Stomaci, V; Martini, M; Fabbricatore, P; Farinon, S; Musenich, R; Alexander, D; Daniel, A; Empl, A; Hungerford, E V; Lau, K; Gollin, G D; Huang, C; Roderick, D; Trundy, B; Brown, D Na; Ding, D; Kolomensky, Yu G; Lee, M J; Cascella, M; Grancagnolo, F; Ignatov, F; Innocente, A; L'Erario, A; Miccoli, A; Maffezzoli, A; Mazzotta, P; Onorato, G; Piacentino, G M; Rella, S; Rossetti, F; Spedicato, M; Tassielli, G; Taurino, A; Zavarise, G; Hooper, R; Brown, D No; Djilkibaev, R; Matushko, V; Ankenbrandt, C; Boi, S; Dychkant, A; Hedin, D; Hodge, Z; Khalatian, V; Majewski, R; Martin, L; Okafor, U; Pohlman, N; Riddel, R S; Shellito, A; de Gouvea, A L; Cervelli, F; Carosi, R; Di Falco, S; Donati, S; Lomtadze, T; Pezzullo, G; Ristori, L; Spinella, F; Jones, M; Corcoran, M D; Orduna, J; Rivera, D; Bennett, R; Caretta, O; Davenne, T; Densham, C; Loveridge, P; Odell, J; Bomgardner, R; Dukes, E C; Ehrlich, R; Frank, M; Goadhouse, S; Ho, E; Ma, H; Oksuzian, Y; Purvis, J; Wu, Y; Hertzog, D W; Kammel, P; Lynch, K R; Popp, J L

    2015-01-01

    The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.

  6. Designing with Protocells: Applications of a Novel Technical Platform

    OpenAIRE

    Rachel Armstrong

    2014-01-01

    The paper offers a design perspective on protocell applications and presents original research that characterizes the life-like qualities of the Bütschli dynamic droplet system, as a particular “species” of protocell. Specific focus is given to the possibility of protocell species becoming a technical platform for designing and engineering life-like solutions to address design challenges. An alternative framing of the protocell, based on process philosophy, sheds light on its capabilities as ...

  7. Digital libraries philosophies, technical design considerations, and example scenarios

    CERN Document Server

    Stern, David

    1999-01-01

    An unparalleled overview of current design considerations for your digital library! Digital Libraries: Philosophies, Technical Design Considerations, and Example Scenarios is a balanced overview of public services, collection development, administration, and systems support, for digital libraries, with advice on adopting the latest technologies that appear on the scene. As a professional in the library and information science field, you will benefit from this special issue that serves as an overview of selected directions, trends, possibilities, limitations, enhancements, design principals, an

  8. Performance of the PrimEx Electromagnetic Calorimeter

    OpenAIRE

    Kubantsev, M.; Larin, I.; A. Gasparyan; Collaboration, for the PrimEx

    2006-01-01

    We report the design and performance of the hybrid electromagnetic calorimeter consisting of 1152 $PbWO_4$ crystals and 576 lead glass blocks for the PrimEx experiment at the Jefferson Laboratory. The detector was built for high precision measurement of the neutral pion lifetime via the Primakoff effect. Calorimeter installation and commissioning was completed with the first physics run in fall of 2004. We present the energy and position resolution of the calorimeter. Obtained $\\pi^0$ mass re...

  9. Muon (g-2) Technical Design Report

    CERN Document Server

    Grange, J; Winter, P; Wood, K; Zhao, H; Carey, R M; Gastler, D; Hazen, E; Kinnaird, N; Miller, J P; Mott, J; Roberts, B L; Benante, J; Crnkovic, J; Morse, W M; Sayed, H; Tishchenko, V; Druzhinin, V P; Khazin, B I; Koop, I A; Logashenko, I; Shatunov, Y M; Solodov, E; Korostelev, M; Newton, D; Wolski, A; Bjorkquist, R; Eggert, N; Frankenthal, A; Gibbons, L; Kim, S; Mikhailichenko, A; Orlov, Y; Rubin, D; Sweigart, D; Allspach, D; Annala, G; Barzi, E; Bourland, K; Brown, G; Casey, B C K; Chappa, S; Convery, M E; Drendel, B; Friedsam, H; Gadfort, T; Hardin, K; Hawke, S; Hayes, S; Jaskierny, W; Johnstone, C; Johnstone, J; Kashikhin, V; Kendziora, C; Kiburg, B; Klebaner, A; Kourbanis, I; Kyle, J; Larson, N; Leveling, A; Lyon, A L; Markley, D; McArthur, D; Merritt, K W; Mokhov, N; Morgan, J P; Nguyen, H; Ostiguy, J-F; Para, A; Popovic, C C Polly M; Ramberg, E; Rominsky, M; Schoo, D; Schultz, R; Still, D; Soha, A K; Strigonov, S; Tassotto, G; Turrioni, D; Villegas, E; Voirin, E; Velev, G; Wolff, D; Worel, C; Wu, J-Y; Zifko, R

    2015-01-01

    The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.

  10. Muon (g-2) Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Grange, J. [Argonne National Lab. (ANL), Argonne, IL (United States); et al.

    2015-01-27

    The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the Standard-Model prediction by more than three standard deviations. When combined with expected improvement in the Standard-Model hadronic contributions, E989 should be able to determine definitively whether or not the E821 result is evidence for physics beyond the Standard Model. After a review of the physics motivation and the basic technique, which will use the muon storage ring built at BNL and now relocated to Fermilab, the design of the new experiment is presented. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2/3 approval.

  11. International workshop on calorimeter simulation

    International Nuclear Information System (INIS)

    The aim of the Juelich workshop was to provide an overview of the state of calorimeter simulation and the methods used. This resulted in 29 contributions to the following topics: Code systems relevant to calorimeter simulation, vectorization and code speed-up, simulation of calorimeter experiments, special applications of calorimeter simulation. This report presents the viewgraphs of the given talks. (orig./HSI)

  12. LHCb calorimeter electronics. Photon identification. Calorimeter calibration

    CERN Document Server

    Machefert, F

    LHCb is one of the four large experiments installed on the LHC accelerator ring. The aim of the detector is to precisely measure CP violation observables and rare decays in the B meson sector. The calorimeter system of LHCb is made of four sub-systems: the scintillating pad detector, the preshower, the electromagnetic (ECAL) and hadronic (HCAL) calorimeters. It is essential to reconstruct B decays, to efficiently trigger on interesting events and to identify electrons and photons. After a review of the LHCb detector sub-systems, the first part of this document describes the calorimeter electronics. First, the front-end electronics in charge of measuring the ECAL and HCAL signals from the photomultipliers is presented, then the following section is an overview of the control card of the four calorimeters. The chapters three and four concern the test software of this electronics and the technological choices making it tolerant to radiations in the LHCb cavern environment. The measurements performed to ensure th...

  13. Refactoring for software design smells managing technical debt

    CERN Document Server

    Suryanarayana, Girish; Sharma, Tushar

    2014-01-01

    Awareness of design smells - indicators of common design problems - helps developers or software engineers understand mistakes made while designing, what design principles were overlooked or misapplied, and what principles need to be applied properly to address those smells through refactoring. Developers and software engineers may ""know"" principles and patterns, but are not aware of the ""smells"" that exist in their design because of wrong or mis-application of principles or patterns. These smells tend to contribute heavily to technical debt - further time owed to fix projects thought to b

  14. Run 1 Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Heelan, Louise; The ATLAS collaboration

    2014-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. It is also useful for identification and reconstruction of muons due to good signal to noise ratio. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 5000 cells, each viewed by two photomultipliers. The calorimeter response and its readout electronics is monitored to better than 1% using radioactive source, laser and charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of proton-proton collisions acquired in 2011 and 2012. Results on the calorimeter performance are presented, including the absolute energy scale, timing, noise and associated stabilities. The results demonstrate that the Tile Calorimeter has performed well within the design ...

  15. Silicon pad detectors for ALICE forward calorimeter

    International Nuclear Information System (INIS)

    A newly designed Electromagnetic Calorimeter (EMC) is being proposed as a possible upgrade in the Forward rapidity region, to enhance the physics capabilities of the ALICE experiment at CERN. Each LHC experiment uses a unique approach, in which preference of the designers and the physics requirements has played a decisive role. The requirement of the design of the calorimeter is to have highly granular layers of detectors consisting of 1 mm2 as well as 1 cm2 silicon pad detectors. The high granular layers (1 mm2) yield good position resolution and tracking of incoming particles. Other active layers, composed of pads of 1 cm2 are used for energy measurement

  16. The ZEUS uranium calorimeter

    International Nuclear Information System (INIS)

    The uranium-scintillator calorimeter of the ZEUS experiment in the HERA electron proton collider at DESY in Hamburg, Germany, is described. It covers 99.8% of the solid angle, has an energy resolution 35%/√E for single hadrons and jets, and 17.5%/√E for electrons. e/h is 1 within 2% in energy range of 2 to 100 GeV. Test beam results show that inter calibration at the 1% level is achievable using uranium radioactivity. The calorimeter was commissioned in April 1992, and has been taken data since May 1992. Main characteristics of the calorimeter construction, readout, and trigger were reviewed. Experience from the first data taking period, including results on noise, stability of calibration, background from HERA accelerator, and performance of the calorimeter trigger is discussed. (author). 28 refs., 21 figs., 1 tab

  17. GSPEL - Calorimeter Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Testing performance claims on heat transfer components The Calorimeter Lab, located in the Ground Systems Power and Energy Lab (GSPEL), is one of the largest in the...

  18. Calorimeters for biotechnology

    International Nuclear Information System (INIS)

    The isothermal and temperature scanning calorimeters manufactured by Calorimetry Sciences Corporation are briefly described. Applications of calorimetry to determine thermodynamics and kinetics of reactions of interest in biotechnology are described with illustrative examples

  19. Socio-technical Spaces: Guiding Politics, Staging Design

    DEFF Research Database (Denmark)

    Clausen, Christian; Yoshinaka, Yutaka

    2005-01-01

    the analysis of two distinct cases: Business Process Reengineering (BPR), and Magnetic Resonance Imaging (MRI) in the light of 'film-less' radiological practice, respectively. Socio-technical space is elaborated as being an occasioning as well as a result of sociotechnical choices and processes. It......This article addresses how insights from the social shaping tradition and political process theory may contribute to an understanding of the sociotechnical design and implementation of change. This idea is pursued through the notion of 'socio-technical spaces' and its delineation, with respect to...... points to the role of socio-material and discursive practices in rendering spaces open to problematisation and action. It is suggested that the notion of socio-technical spaces helps generate a sensitising guide for researchers and practitioners, and is proposed as a constructive means to localising...

  20. The international linear collider. Technical design report. Vol. 1. Executive summary

    Energy Technology Data Exchange (ETDEWEB)

    Behnke, Ties; Brau, James E.; Foster, Brian; Fuster, Juan; Harrison, Mike; McEwan Paterson, James; Peskin, Michael; Stanitzki, Marcel; Walker, Nicholas; Yamamoto, Hitoshi (eds.)

    2013-07-01

    A review is given about the planned International Linear Collider. Especially described are the technical design, the accelerator layout and design, the R and D during the technical design phase, and the detectors. (HSI)

  1. The international linear collider. Technical design report. Vol. 1. Executive summary

    International Nuclear Information System (INIS)

    A review is given about the planned International Linear Collider. Especially described are the technical design, the accelerator layout and design, the R and D during the technical design phase, and the detectors. (HSI)

  2. PEP-4 geiger-mode hexagonal calorimeter

    International Nuclear Information System (INIS)

    The design and performance of the calorimeter are briefly described. Design aspects include illustrations of the active volume of the detector, edge connections, module assembly and analog electronics. Performance data for cosmic rays and radiation sources, including efficiency and channel sensitivity are discussed

  3. Study of job burnout in technical writers and technical illustrators/designers at LLNL

    Energy Technology Data Exchange (ETDEWEB)

    Rice, J A

    1998-06-03

    According to the American Institute of Stress, job stress is estimated to cost American industry more than $200 billion a year. These costs are, in part, related to the estimated 1 million employees that will be absent on an average workday because of stress; 75 percent of visits to primary care physicians are for stress-related problems. California workers' compensation claims for stress cost $1 billion for medical and legal fees alone (Murphy, 1997). But, there is another dimension to stress that needs to be addressed. Job stress can be a precursor to job burnout. Burnout is a loss of motivation, and antidotes for job stress will not necessarily alleviate or stop job burnout. Job burnout is experienced as exhaustion on physical, emotional, and cognitive levels. Burnout can include withdrawal and decreasing involvement on the job, seriously affecting job satisfaction, turnover, absenteeism, and productivity (Dwyer & Ganster, 1991; Erickson & Gunderson, 1972; Spector & Jex, 1991). The research project described in this paper examined whether job burnout exists in the technical writer and technical illustrator/designer occupations in the Technical Information Department at Lawrence Livermore National Laboratory. This study also determined at what age and after how many years of service these employees were most likely to experience job burnout, whether it affects men or women most, and if writers in a technical organization experience job burnout more than illustrators/designers in that organization.

  4. Technical basis for the ITER-FEAT outline design. Progress in resolving open design issues from the outline design report

    International Nuclear Information System (INIS)

    In this publication the technical basis for the ITER-FEAT outline design is presented. It comprises the Plant Design Specifications, the Safety Principles and Environmental Criteria, the Site Requirements and Site Design Assumptions. The outline of the key features of the ITER-FEAT design includes main physical parameters and assessment, design overview and preliminary safety assessment, cost and schedule

  5. Development and Construction of Large Size Signal Electrodes for the ATLAS Electromagnetic Calorimeter

    CERN Document Server

    Aubert, B; Colas, Jacques; Girard, C; Jérémie, A; Jézéquel, S; Lesueur, J; Sauvage, G; Lissauer, D; Makowiecki, D S; Radeka, V; Rescia, S; Wolniewicz, K; Belymam, A; Hoummada, A; Cherif, A; Chevalley, J L; Hervás, L; Marin, C P; Fassnacht, P; Szeless, Balázs; Collot, J; Gallin-Martel, M L; Hostachy, J Y; Martin, P; Leltchouk, M; Seman, M; Dargent, P; Djama, F; Monnier, E; Olivier, C; Tisserant, S; Battistoni, G; Carminati, L; Cavalli, D; Costa, G; Delmastro, M; Fanti, M; Mandelli, L; Mazzanti, M; Perini, L; Tartarelli, F; Augé, E; Bonivento, W; Fournier, D; Puzo, P; Serin, L; de La Taille, C; Astesan, F; Canton, B; Imbault, D; Lacour, D; Rossel, F; Schwemling, P

    2005-01-01

    We describe the electric circuits (electrodes) which polarize and read out the Lead-Liquid Argon electromagnetic calorimeter for the ATLAS detector. The paper covers design and material choices of the circuits as well as their production in industry. We also show how the electrodes integrate into the calorimeter and conclude with results from groups of electrodes making up calorimeter modules.

  6. Technical Shortcomings of Designing and Implementing a Knowledge Management System

    OpenAIRE

    Mohammadreza Hamidizadeh; Seyed Akbar Nilipour Tabatabaei; Maryam Gholizadeh

    2014-01-01

    The purpose of the current research is to recognize technical shortcomings of designing and implementing a knowledge management system. The research population include two companies: Zobahan Esfahan Company and International Automation and Systems Engineering Company (IRISA) in which the staffs work in different departments such as research and development, method and structure, strategic planning, instruction, and information technology. applying a stratified random sampling, 50 samples were...

  7. Designing with protocells: applications of a novel technical platform.

    Science.gov (United States)

    Armstrong, Rachel

    2014-01-01

    The paper offers a design perspective on protocell applications and presents original research that characterizes the life-like qualities of the Bütschli dynamic droplet system, as a particular "species" of protocell. Specific focus is given to the possibility of protocell species becoming a technical platform for designing and engineering life-like solutions to address design challenges. An alternative framing of the protocell, based on process philosophy, sheds light on its capabilities as a technology that can deal with probability and whose ontology is consistent with complexity, nonlinear dynamics and the flow of energy and matter. However, the proposed technical systems do not yet formally exist as products or mature technologies. Their potential applications are therefore experimentally examined within a design context as architectural "projects"-an established way of considering proposals that have not yet been realized, like an extended hypothesis. Exemplary design-led projects are introduced, such as The Hylozoic Ground and Future Venice, which aim to "discover", rather than "solve", challenges to examine a set of possibilities that have not yet been resolved. The value of such exploration in design practice is in opening up a set of potential directions for further assessment before complex challenges are procedurally implemented. PMID:25370381

  8. Designing with Protocells: Applications of a Novel Technical Platform

    Directory of Open Access Journals (Sweden)

    Rachel Armstrong

    2014-09-01

    Full Text Available The paper offers a design perspective on protocell applications and presents original research that characterizes the life-like qualities of the Bütschli dynamic droplet system, as a particular “species” of protocell. Specific focus is given to the possibility of protocell species becoming a technical platform for designing and engineering life-like solutions to address design challenges. An alternative framing of the protocell, based on process philosophy, sheds light on its capabilities as a technology that can deal with probability and whose ontology is consistent with complexity, nonlinear dynamics and the flow of energy and matter. However, the proposed technical systems do not yet formally exist as products or mature technologies. Their potential applications are therefore experimentally examined within a design context as architectural “projects”—an established way of considering proposals that have not yet been realized, like an extended hypothesis. Exemplary design-led projects are introduced, such as The Hylozoic Ground and Future Venice, which aim to “discover”, rather than “solve”, challenges to examine a set of possibilities that have not yet been resolved. The value of such exploration in design practice is in opening up a set of potential directions for further assessment before complex challenges are procedurally implemented.

  9. Technical guidelines for aseismic design of nuclear power plants

    International Nuclear Information System (INIS)

    This document is a translation, in its entirety, of the Japan Electric Association (JEA) publication entitled open-quotes Technical Guidelines for Aseismic Design of Nuclear Power Plants - JEAG 4601-1987.close quotes This guideline describes in detail the aseismic design techniques used in Japan for nuclear power plants. It contains chapters dealing with: (a)the selection of earthquake ground motions for a site, (b) the investigation of foundation and bedrock conditions, (c) the evaluation of ground stability and the effects of ground movement on buried piping and structures, (d) the analysis and design of structures, and (e) the analysis and design of equipment and distribution systems (piping, electrical raceways, instrumentation, tubing and HVAC duct). The guideline also includes appendices which summarize data, information and references related to aseismic design technology

  10. Development of a forward calorimeter system for the STAR experiment

    International Nuclear Information System (INIS)

    We present results of an R and D program to develop a forward calorimeter system (FCS) for the STAR experiment at the Relativistic Heavy Ion Collider at BNL. The FCS is a very compact, compensated, finely granulated, high resolution calorimeter system being developed for p+p and p+A program at RHIC. The FCS prototype consists of both electromagnetic and hadron calorimeters. The electromagnetic portion of the detector is constructed with W powder and scintillation fibers. The hadronic calorimeter is a traditional Pb/Sc-plate sandwich design. Both calorimeters were readout with Hamamatsu MPPCs. A full- scale prototype of the FCS was tested with a beam at FNAL in March 2014. We present details of the design, construction technique and performance of the FCS prototype during the test run at FNAL

  11. Hadron showers in a highly granular calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, Benjamin

    2010-11-15

    A future electron-positron collider like the planned International Linear Collider (ILC) needs excellent detectors to exploit the full physics potential. Different detector concepts have been evaluated for the ILC and two concepts on the particle-flow approach were validated. To make particle-flow work, a new type of imaging calorimeters is necessary in combination with a high performance tracking system, to be able to track the single particles through the full detector system. These calorimeters require an unprecedented level of both longitudinal and lateral granularity. Several calorimeter technologies promise to reach the required readout segmentation and are currently studied. This thesis addresses one of these: The analogue hadron calorimeter technology. It combines work on the technological aspects of a highly granular calorimeter with the study of hadron shower physics. The analogue hadron calorimeter technology joins a classical scintillator-steel sandwich design with a modern photo-sensor technology, the silicon photomultiplier (SiPM). The SiPM is a millimetre sized, magnetic field insensitive, and low cost photo-sensor, that opens new possibilities in calorimeter design. This thesis outlines the working principle and characteristics of these devices. The requirements for an application specific integrated circuit (ASIC) to read the SiPM are discussed; the performance of a prototype chip for SiPM readout, the SPIROC, is quantified. Also the SiPM specific reconstruction of a multi-thousand channel prototype calorimeter, the CALICE AHCAL, is explained; the systematic uncertainty of the calibration method is derived. The AHCAL does not only offer a test of the calorimeter technology, it also allows to record hadron showers with an unprecedented level of details. Test-beam measurements have been performed with the AHCAL and provide a unique sample for the development of novel analysis techniques and the validation of hadron shower simulations. A method to

  12. Hadron showers in a highly granular calorimeter

    International Nuclear Information System (INIS)

    A future electron-positron collider like the planned International Linear Collider (ILC) needs excellent detectors to exploit the full physics potential. Different detector concepts have been evaluated for the ILC and two concepts on the particle-flow approach were validated. To make particle-flow work, a new type of imaging calorimeters is necessary in combination with a high performance tracking system, to be able to track the single particles through the full detector system. These calorimeters require an unprecedented level of both longitudinal and lateral granularity. Several calorimeter technologies promise to reach the required readout segmentation and are currently studied. This thesis addresses one of these: The analogue hadron calorimeter technology. It combines work on the technological aspects of a highly granular calorimeter with the study of hadron shower physics. The analogue hadron calorimeter technology joins a classical scintillator-steel sandwich design with a modern photo-sensor technology, the silicon photomultiplier (SiPM). The SiPM is a millimetre sized, magnetic field insensitive, and low cost photo-sensor, that opens new possibilities in calorimeter design. This thesis outlines the working principle and characteristics of these devices. The requirements for an application specific integrated circuit (ASIC) to read the SiPM are discussed; the performance of a prototype chip for SiPM readout, the SPIROC, is quantified. Also the SiPM specific reconstruction of a multi-thousand channel prototype calorimeter, the CALICE AHCAL, is explained; the systematic uncertainty of the calibration method is derived. The AHCAL does not only offer a test of the calorimeter technology, it also allows to record hadron showers with an unprecedented level of details. Test-beam measurements have been performed with the AHCAL and provide a unique sample for the development of novel analysis techniques and the validation of hadron shower simulations. A method to

  13. ATLAS - End-Cap calorimeter

    CERN Multimedia

    2006-01-01

    The End-cap calorimeter was moved with the help of the rails and this calorimeter will measure the energy of particles close to the beam axis when protons collide. Cooling is important for maximum detector efficiency.

  14. Testing a liquid Argon calorimeter

    CERN Multimedia

    1976-01-01

    Physicists from Karlsruhe test a liquid argon calorimeter in the neutral beam b16 at the PS. The calorimeter was meant to supply some neutral particles identification at the Split-Field Magnet Facility for R416.

  15. The ATLAS Tile Calorimeter

    CERN Document Server

    Henriques Correia, Ana Maria

    2015-01-01

    TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics.

  16. Performance of the ATLAS hadronic Tile calorimeter

    CERN Document Server

    Bartos, Pavol; The ATLAS collaboration

    2016-01-01

    Performance of the ATLAS hadronic Tile calorimeter The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau-particles and missing transverse energy. TileCal is a scintillator-steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the scintillator tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal frontend electronics reads out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. Each stage of the signal production from scintillation light to the signal reconstruction is monitored and calibrated. The performance of the calorimeter have been studied in-situ employing cosmic ray muons and a large sample of proton-proton collisions acquired during the operations o...

  17. ALICE Zero Degree Calorimeter

    CERN Multimedia

    De Marco, N

    2013-01-01

    Two identical sets of calorimeters are located on both sides with respect to the beam Interaction Point (IP), 112.5 m away from it. Each set of detectors consists of a neutron (ZN) and a proton (ZP) Zero Degree Calorimeter (ZDC), positioned on remotely controlled platforms. The ZN is placed at zero degree with respect to the LHC beam axis, between the two beam pipes, while the ZP is positioned externally to the outgoing beam pipe. The spectator protons are separated from the ion beams by means of the dipole magnet D1.

  18. Calibration of the CREAM-I calorimeter

    CERN Document Server

    Yoon, Y S; Bagliesi, M G; Bigongiari, G; Ganel, O; Han, J H; Jeon, J A; Kim, K C; Lee, M H; Lutz, L; Maestro, P; Malinin, A; Marrocchesi, P S; Nam, S; Park, I H; Park, N H; Seo, E S; Sina, R; Wu, J; Yang, J; Zei, R; Zinn, S Y

    2010-01-01

    The Cosmic Ray Energetics And Mass (CREAM) calorimeter is designed to measure the spectra of cosmic-ray particles over the energy range from ~10^11 eV to ~10^15 eV. Its first flight as part of the CREAM-I balloon-borne payload in Antarctica during the 2004/05 season resulted in a recordbreaking 42 days of exposure. Calorimeter calibration using various beam test data will be discussed in an attempt to assess the uncertainties of the energy measurements.

  19. Rad Hard Active Media For Calorimeters

    CERN Document Server

    Norbeck, E; Möller, A; Onel, Y

    2006-01-01

    Zero-degree calorimeters have limited space and extreme levels of radiation. A simple, low cost, radiation hard design uses tungstenmetal as the absorber and a suitable liquid as the ˇCerenkov radiator. In other applications a PPAC (Parallel Plate Avalanche Counter) operatingwith a suitable atmosphericpressure gas is an attractive active material for a calorimeter. It can be made radiation hard and has sufficient gain in the gas that no electronic components are needed near the detector. It works well even with the highest concentration of shower particles. For this pressure range, R134A (used in auto air conditioners) has many desirable features.

  20. MAC calorimeters and applications

    International Nuclear Information System (INIS)

    The MAC detector at PEP features a large solid-angle electromagnetic/hadronic calorimeter system, augmented by magnetic charged-particle tracking, muon analysis and scintillator triggering. Its implementation in the context of electron-positron annihilation physics is described, with emphasis on the utilization of calorimetry

  1. Geiger projection calorimeter

    International Nuclear Information System (INIS)

    In view of a second generation p-decay experiment in the Gran Sasso Laboratory, a digital tracking calorimeter is being developed, based on the use of plastic tubes of the Mont Blanc detector type, which are operated in limited Geiser mode

  2. Gas calorimeter workshop: proceedings

    International Nuclear Information System (INIS)

    Gas calorimeters combining functions of energy measurement and fine tracking have become more and more popular in the past few years. They help identify muons, gammas, electrons, and hadrons within dense tracks from transverse and longitudinal shower development. Fine segmentation capability using pads and strips on the cathodes have made gas-sampling calorimeters very attractive for colliding-beam detectors where a large multiplicity of particles are detected in a projected geometry. Linearity, energy resolution, shower position resolution, multishower resolution, and calibration questions were discussed in detail at the workshop. Ease of energy calibration by monitoring radioactive sources, good gain uniformity, and gain stability obtained were among the topics of the speakers. There was a discussion session on the operation mode of wire chambers. Gas calorimeters have been used successfully at CERN, Cornell, Fermilab, and SLAC for experiments. Some of the results from those large-scale devices were reported. Future usage of gas-sampling calorimeters for colliding-beam experiments at Fermilab and CERN were discussed. Wire chambers using extruded conductive plastic tubes have made construction easy of pads and strips which can conveniently read out induced signals from the cathode. The results of extensive studies on such devices were discussed. Separate entries were prepared for the data base for the 17 papers presented

  3. The ATLAS tile calorimeter

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Louis Rose-Dulcina, a technician from the ATLAS collaboration, works on the ATLAS tile calorimeter. Special manufacturing techniques were developed to mass produce the thousands of elements in this detector. Tile detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  4. Status of the SIP designs and their technical evaluation

    International Nuclear Information System (INIS)

    Support of the State Nuclear Regulatory Committee of Ukraine in SIP (Shelter Implementation Plan) licensing is provided by the State Scientific and Technical Center (SSTC) and the licensing consultant (LC -RISKAUDIT/SCIENTECH). Their primary function is to provide technical evaluation (TE) of SIP designs, namely joint review by SSTC and LC, coordination of other regulatory agency (RA) reviews (concerning construction, health, ecology, fire, other) and interaction with Chernobyl NPP to solve open safety issues. With respect to the stabilization of the most hazardous structure and shielding, the status detailed design, TE results and safety issues of special interest are presented. The Integrated Monitoring Systems (IAMS) and a New Safe Confinement (NSC) are discussed (NSC). The tasks of NSC are: - to ensure isolation of fuel containing materials and radioactive waste (FCM/RW); - to allow dismantlement of unstable structures; - to provide for removal of FCM/RW; - to ensure safety of NSC operating personnel. In connection with those tasks, status of conceptual design, TE results and safety issues of special interest are discussed

  5. Status of the SIP designs and their technical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kondralyev, S.; Bachner, D.; Bykov, V.; Erickson, L.; Inyushev, V.; Kadkin, E.; Korovaenko, I.; Kritsky, V.; Sklyarenko, V.; Smyshliaeva, S. [SSTC NRS, Stusa St. 36-37, 03142, Kyiv (Ukraine)

    2003-07-01

    Support of the State Nuclear Regulatory Committee of Ukraine in SIP (Shelter Implementation Plan) licensing is provided by the State Scientific and Technical Center (SSTC) and the licensing consultant (LC -RISKAUDIT/SCIENTECH). Their primary function is to provide technical evaluation (TE) of SIP designs, namely joint review by SSTC and LC, coordination of other regulatory agency (RA) reviews (concerning construction, health, ecology, fire, other) and interaction with Chernobyl NPP to solve open safety issues. With respect to the stabilization of the most hazardous structure and shielding, the status detailed design, TE results and safety issues of special interest are presented. The Integrated Monitoring Systems (IAMS) and a New Safe Confinement (NSC) are discussed (NSC). The tasks of NSC are: - to ensure isolation of fuel containing materials and radioactive waste (FCM/RW); - to allow dismantlement of unstable structures; - to provide for removal of FCM/RW; - to ensure safety of NSC operating personnel. In connection with those tasks, status of conceptual design, TE results and safety issues of special interest are discussed.

  6. Automatic low-temperature calorimeter

    International Nuclear Information System (INIS)

    This paper describes a low-temperature adiabatic calorimeter with a range of 1.5-500K. The system for maintaining adiabatic conditions is implemented by two resitance thermometers, whose sensitivity at low temperatures is several orders higher than that of thermocouples. The calorimeter cryostat is installed in an STG-40 portable Dewar flask. The calorimeter is controlled by an Elektronika-60 microcomputer. Standard platinum and germanium thermometers were placed inside of the calorimeter to calibrate the thermometers of the calorimeter and the shield, and the specific heats of specimens of OSCh 11-4 copper and KTP-8 paste were measured to demonstrate the possibilities of the described calorimeter. Experience with the calorimeter has shown that a thorough study of the dependence of heat capacity on temperature (over 100 points for one specimen) can be performed in one or two dats

  7. Any light particle search II. Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Baehre, Robin [Albert Einstein Institute, Hannover (Germany); Doebrich, Babette; Dreyling-Eschweiler, Jan [Deutsches Elektronen-Synchrotron, Hamburg (Germany)] [and others

    2013-02-15

    This document constitutes an excerpt of the Technical Design Report for the second stage of the ''Any Light Particle Search'' (ALPS-II) at DESY as submitted to the DESY PRC in August 2012 and reviewed in November 2012. ALPS-II is a ''Light Shining through a Wall'' experiment which searches for photon oscillations into weakly interacting sub-eV particles. These are often predicted by extensions of the Standard Model and motivated by astrophysical phenomena. The first phases of the ALPS-II project were approved by the DESY management on February 21st, 2013.

  8. Any light particle search II. Technical Design Report

    International Nuclear Information System (INIS)

    This document constitutes an excerpt of the Technical Design Report for the second stage of the ''Any Light Particle Search'' (ALPS-II) at DESY as submitted to the DESY PRC in August 2012 and reviewed in November 2012. ALPS-II is a ''Light Shining through a Wall'' experiment which searches for photon oscillations into weakly interacting sub-eV particles. These are often predicted by extensions of the Standard Model and motivated by astrophysical phenomena. The first phases of the ALPS-II project were approved by the DESY management on February 21st, 2013.

  9. Any Light Particle Search II -- Technical Design Report

    OpenAIRE

    Baehre, R.; Doebrich, B.; Ringwald, A.; von Seggern, J. E.; Stromhagen, R.; Trines, D.; Willke, B; Dreyling-Eschweiler, J.; Ghazaryan, S.; Hodajerdi, R.; Horns, D.; Januschek, F.; Knabbe, E.-A.; Lindner, A.; Notz, D.

    2013-01-01

    This document constitutes an excerpt of the Technical Design Report for the second stage of the "Any Light Particle Search" (ALPS-II) at DESY as submitted to the DESY PRC in August 2012 and reviewed in November 2012. ALPS-II is a "Light Shining through a Wall" experiment which searches for photon oscillations into weakly interacting sub-eV particles. These are often predicted by extensions of the Standard Model and motivated by astrophysical phenomena. The first phases of the ALPS-II project ...

  10. Development and Test of the Cooling System for the ATLAS Hadron Tile Calorimeter

    CERN Document Server

    Schlager, Gerolf

    2002-01-01

    The ATLAS detector is a general-purpose experiment for proton-proton collisions designed to investigate the full range of physical processes at the Large Hadron Collider (LHC). The ATLAS Tile Hadron Calorimeter is designed to measure the energies of jets with a resolution of E/E = 50%/pE 3%, for j j<3. This thesis presents the detailed studies which were carried out with prototypes of the Tilecal cooling system during my year as technical student at CERN. The results will be used to validate and to determine the nal design of the cooling system of the ATLAS Tile calorimeter. The performance of the cooling unit built for the calibration of Tilecal modules was evaluated for various parameters like temperature stability and safety conditions during operation. Additionally I contributed to the analysis of the calorimeter response for di erent cooling temperatures. These results determined the constraints on the operation conditions of the cooling system in terms of temperature stability that will be needed d...

  11. The electromagnetic calorimeter for the solenoidal tracker at RHIC

    International Nuclear Information System (INIS)

    This report discusses the following on the electromagnetic calorimeter for the solenoidal tracker at RHIC: conceptual design; the physics of electromagnetic calorimetry in STAR; trigger capability; integration into STAR; and cost, schedule, manpower, and funding

  12. Summary talk on fiber tower calorimeter for the scintillation calorimeter subgroups

    International Nuclear Information System (INIS)

    We present here a new calorimeter design based on small scintillator tiles, lead absorber and wavelength shifting fiber readout. We have addressed all the major issues in SSC calorimetry and have developed a design with many advantageous features. It has been well demonstrated that the best resolution is obtained for a 'compensated' calorimeter. It is also well known how such compensation may be achieved by a suitable choice of active and passive materials and their relative thickness. One such choice is that of lead and scintillator for which the best thickness ratio is 4:1. This selection has been used in the development of the so-called spaghetti calorimeter (SPACAL) discussed at this workshop. The relative merits of this and many other designs have been the subject of much discussion at SSC workshops from which a number of critical issues have emerged for each design. In the present paper, we have addressed the issues raised in the SPACAL design and proposed an alternative, improved design. The SPACAL represents a significant step forward in calorimeter design, but there are always areas which can be improved in any design when it is subjected to detailed study. Specifically we have considered the areas of energy resolution, channeling, projective towers/calibration, longitudinal segmentation, and radiation sensitivity. We will now discuss each of these areas in turn. 5 refs., 9 figs

  13. The International Linear Collider Technical Design Report - Volume 4: Detectors

    CERN Document Server

    ed.; Burrows, Philip N.; Fuster, Juan; Peskin, Michael; Stanitzki, Marcel; Sugimoto, Yasuhiro; Yamada, Sakue; Yamamoto, Hitoshi

    2013-01-01

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to incr...

  14. Technical Design Studies of TAC SASE FEL Proposal

    CERN Document Server

    Ketenoglu, B; Tural, M; Ozkorucuklu, S; Tapan, I; Sahin, O; Arikan, P

    2009-01-01

    A SASE FEL facility was first proposed in Feasibility Report of the TAC (Turkish Accelerator Center) project in 2000. Conceptual Design Report (CDR) of the project was completed in 2005. Technical Design Report (TDR) studies of TAC were started in 2006 in frame of an inter universities project with support of State Planning Organization (SPO) of Turkey. Main goal of the SASE FEL proposal is to cover VUV and soft X-rays region of the spectrum besides IR-FEL, Bremsstrahlung and Synchrotron Radiation proposals of TAC. Up to now, optimization studies based on a special RF linac or an Energy Recovery Linac (ERL) for the SASE FEL facility, were completed. Today, ERLs provide a powerful broad range of applications like: electron cooling devices, high average brightness, high power FELs, short-pulse radiation sources and high luminosity colliders. In this study, main parameters for two linac options and SASE FEL are given.

  15. SPIROC: design and performances of a dedicated very front-end electronics for an ILC Analog Hadronic CALorimeter (AHCAL) prototype with SiPM read-out

    International Nuclear Information System (INIS)

    For the future e+ e- International Linear Collider (ILC) the ASIC SPIROC (Silicon Photomultiplier Integrated Read-Out Chip) was designed to read out the Analog Hadronic Calorimeter (AHCAL) equipped with Silicon Photomultiplier (SiPM). It is an evolution of the FLCSiPM chip designed by the OMEGA group in 2005. SPIROC2 [1] was realized in AMS SiGe 0.35 μm technology [2] and developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of read-out channels. This ASIC is a very front-end read-out chip that integrates 36 self triggered channels with variable gain to achieve charge and time measurements. The charge measurement must be performed from 1 up to 2000 photo-electrons (p.e.) corresponding to 160 fC up to 320 pC for SiPM gain 106. The time measurement is performed with a coarse 12-bit counter related to the bunch crossing clock (up to 5 MHz) and a fine time ramp based on this clock (down to 200 ns) to achieve a resolution of 1 ns. An analog memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. The analog memory content (time and charge) is digitized thanks to an internal 12-bit Wilkinson ADC. The data is then stored in a 4kbytes RAM. A complex digital part is necessary to manage all these features and to transfer the data to the DAQ. SPIROC2 is the second generation of the SPIROC ASIC family designed in 2008 by the OMEGA group. A very similar version (SPIROC2c) was submitted in February 2012 to improve the noise performance and also to integrate a new TDC (Time to Digital Converter) structure. This paper describes SPIROC2 and SPIROC2c ASICs and illustrates the main characteristics thank to a series of measurements.

  16. NEXT-100 Technical Design Report (TDR). Executive Summary

    CERN Document Server

    ,

    2012-01-01

    In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay in Xe-136. The document formalizes the ANGEL design presented in our Conceptual Design Report (CDR). The baseline detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The ANGEL design calls for an asymmetric TPC, with photomultipliers behind a transparent cathode and position-sensitive light pixels behind the anode. We have chosen the low background R11410-10 PMTs for energy and timing and Hamamatsu MPPCs (S10362-11-050P model) as tracking pixels. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window coated with terphenyl-butadiene (TPB) . MPPCs will be arranged in Dice Boards (DB) holding 64 senso...

  17. NEXT-100 Technical Design Report (TDR). Executive summary

    Science.gov (United States)

    Álvarez, V.; Borges, F. I. G. M.; Cárcel, S.; Carmona, J. M.; Castel, J.; Catalá, J. M.; Cebrián, S.; Cervera, A.; Chan, D.; Conde, C. A. N.; Dafni, T.; Dias, T. H. V. T.; Díaz, J.; Egorov, M.; Esteve, R.; Evtoukhovitch, P.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Ferrer-Ribas, E.; Freitas, E. D. C.; Gehman, V. M.; Gil, A.; Giomataris, I.; Goldschmidt, A.; Gómez, H.; Gómez-Cadenas, J. J.; González, K.; González-Díaz, D.; Gutiérrez, R. M.; Hauptman, J.; Hernando Morata, J. A.; Herrera, D. C.; Herrero, V.; Iguaz, F. J.; Irastorza, I. G.; Kalinnikov, V.; Kiang, D.; Labarga, L.; Liubarsky, I.; Lopes, J. A. M.; Lorca, D.; Losada, M.; Luzón, G.; Marí, A.; Martín-Albo, J.; Martínez, A.; Miller, T.; Moiseenko, A.; Monrabal, F.; Monteiro, C. M. B.; Monzó, J. M.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Natal da Luz, H.; Navarro, G.; Nebot, M.; Nygren, D.; Oliveira, C. A. B.; Palma, R.; Pérez, J.; Pérez Aparicio, J. L.; Renner, J.; Ripoll, L.; Rodríguez, A.; Rodríguez, J.; Santos, F. P.; dos Santos, J. M. F.; Segui, L.; Serra, L.; Shuman, D.; Sofka, C.; Sorel, M.; Toledo, J. F.; Tomás, A.; Torrent, J.; Tsamalaidze, Z.; Vázquez, D.; Velicheva, E.; Veloso, J. F. C. A.; Villar, J. A.; Webb, R. C.; Weber, T.; White, J.; Yahlali, N.

    2012-06-01

    In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ββ0ν) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 × 8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.

  18. NA48 prototype calorimeter

    CERN Multimedia

    1990-01-01

    This is a calorimeter, a detector which measures the energy of particles. When in use, it is filled with liquid krypton at -152°C. Electrons and photons passing through interact with the krypton, creating a shower of charged particles which are collected on the copper ribbons. The ribbons are aligned to an accuracy of a tenth of a millimetre. The folding at each end allows them to be kept absolutely flat. Each shower of particles also creates a signal in scintillating material embedded in the support disks. These flashes of light are transmitted to electronics by the optical fibres along the side of the detector. They give the time at which the interaction occurred. The photo shows the calorimeter at NA48, a CERN experiment which is trying to understand the lack of anti-matter in the Universe today.

  19. UA2 central calorimeter

    CERN Multimedia

    The UA2 central calorimeter measured the energy of individual particles created in proton-antiproton collisions. Accurate calibration allowed the W and Z masses to be measured with a precision of about 1%. The calorimeter had 24 slices like this one, each weighing 4 tons. The slices were arranged like orange segments around the collision point. Incoming particles produced showers of secondary particles in the layers of heavy material. These showers passed through the layers of plastic scintillator, generating light which was taken by light guides (green) to the data collection electronics. The amount of light was proportional to the energy of the original particle. The inner 23 cm of lead and plastic sandwiches measured electrons and photons; the outer 80 cm of iron and plastic sandwiches measured strongly interacting hadrons. The detector was calibrated by injecting light through optical fibres or by placing a radioactive source in the tube on the bottom edge.

  20. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    Roger Rusack

    Occupancy of the trigger primitives during a global run: the observed pattern is consistent with the polar angle dependence of the transverse energy equivalent of the electronic noise in the endcaps.   Progress on ECAL since the last CMS week has been mostly on three major fronts: we have continued with the installation and commissioning of the preshower detectors; the endcap calorimeter trigger has been installed and tested; and there have been many changes to the calorimeter detector control and safety systems. Both Preshower (ES) endcaps were installed in CMS on schedule, just before Easter. There followed a campaign of "first commissioning" to ensure that all services were correctly connected (electrical, optical, cooling, etc.). Apart from some optical ribbons that had to be replaced the process went rather smoothly, finishing on 23rd April. All power supplies are installed and operational. The cooling system (two branches of the joint Tracker-Preshower system) is fully fun...

  1. The International Linear Collider Technical Design Report - Volume 3.I: Accelerator R&D in the Technical Design Phase

    CERN Document Server

    Adolphsen, Chris; Barish, Barry; Buesser, Karsten; Burrows, Philip; Carwardine, John; Clark, Jeffrey; Durand, Hélène Mainaud; Dugan, Gerry; Elsen, Eckhard; Enomoto, Atsushi; Foster, Brian; Fukuda, Shigeki; Gai, Wei; Gastal, Martin; Geng, Rongli; Ginsburg, Camille; Guiducci, Susanna; Harrison, Mike; Hayano, Hitoshi; Kershaw, Keith; Kubo, Kiyoshi; Kuchler, Victor; List, Benno; Liu, Wanming; Michizono, Shinichiro; Nantista, Christopher; Osborne, John; Palmer, Mark; Paterson, James McEwan; Peterson, Thomas; Phinney, Nan; Pierini, Paolo; Ross, Marc; Rubin, David; Seryi, Andrei; Sheppard, John; Solyak, Nikolay; Stapnes, Steinar; Tauchi, Toshiaki; Toge, Nobu; Walker, Nicholas; Yamamoto, Akira; Yokoya, Kaoru

    2013-01-01

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to incr...

  2. The CMS Outer Hadron Calorimeter

    CERN Document Server

    Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Bawa, Harinder Singh; Beri, Suman Bala; Bhandari, Virender; Bhatnagar, Vipin; Chendvankar, Sanjay; Deshpande, Pandurang Vishnu; Dugad, Shashikant; Ganguli, Som N; Guchait, Monoranjan; Gurtu, Atul; Kalmani, Suresh Devendrappa; Kaur, Manjit; Kohli, Jatinder Mohan; Krishnaswamy, Marthi Ramaswamy; Kumar, Arun; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Narasimham, Vemuri Syamala; Patil, Mandakini Ravindra; Reddy, L V; Satyanarayana, B; Sharma, Seema; Singh, B; Singh, Jas Bir; Sudhakar, Katta; Tonwar, Suresh C; Verma, Piyush

    2006-01-01

    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with a outer calorimeter to ensure high energy shower containment in CMS and thus working as a tail catcher. Fabrication, testing and calibrations of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing $\\et$ measurements at LHC energies. The outer hadron calorimeter has a very good signal to background ratio even for a minimum ionising particle and can hence be used in coincidence with the Resistive Plate Chambers of the CMS detector for the muon trigger.

  3. Energy Resolution Performance of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Auffray, Etiennette; Baccaro, Stefania; Baffioni, Stephanie; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Berthon, Ursula; Betev, Botjo; Beuselinck, Raymond; Bhardwaj, Ashutosh; Biino, Cristina; Bimbot, Stephane; Blaha, Jan; Bloch, Philippe; Blyth, Simon; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton1, D; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Cerutti, Muriel; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chatterji, Sudeep; Chen, E Augustine; Chipaux, Rémi; Choudhary, Brajesh C; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Cossutti, Fabio; Costantini, Silvia; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; Debraine, Alain; Decotigny, David; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Della Negra, Rodolphe; Della Ricca, Giuseppe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Golutvin, Igor; Gómez-Reino, Robert; Govoni, Pietro; Grahl1, J; Gras1, P; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel-de-Montechenault, G; Hansen, Magnus; Heath, Helen F; AHill, J; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Jarry, Patrick; Jauffret, C; Jha, Manoj; Karar, Akli; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Litvin, V; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Luckey, D; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Malberti, Martina; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Mathieu, Antoine; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman26, H B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Poilleux, Patrick; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rahatlou, Shahram; Rander, John; Ranjan, Kirti; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rumerio, Paolo; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Seez, Christopher; Semeniouk, Igor; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Yves; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Timlin, Claire; ATriantis, F; Troshin, Sergey; Tyurin, Nikolay; Ueno, Koji; Uzunian, Andrey; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Vigano, S; Viertel, Gert; Virdee, Tejinder; Vlassov, E; Wang, Minzu; Weinstein, Alan; Williams, Jennifer C; Yaselli, Ignacio; Zabi, Alexandre; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhang, Yawei; Zhu, Kejun; Zhu, Ren-Yuan

    2006-01-01

    The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals.

  4. The Electromagnetic Barrel Calorimeter for the GlueX Experiment

    International Nuclear Information System (INIS)

    The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number of approximately 3000 readout channels with silicon-photomultiplier-based photo-sensors for light collection. The calorimeter is expected to achieve energy and time resolution better than 5% bigsl √(E)+ 2% and 200 ps, respectively. In this contribution we present an overview of the calorimeter design and some preliminary studies of its performance using Monte Carlo simulations and beam test measurements

  5. The Electromagentic Barrel Calorimeter for the GlueX Experiment

    CERN Document Server

    Barbi, M

    2006-01-01

    The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number of approximately 3000 readout channels with silicon photomultiplier-based photo-sensors for light collection. The calorimeter is expected to achieve energy and time resolution better than 5%/sqrt(E)+2% and 200 ps, respectively. In this contribution we present an overview of the calorimeter design and some preliminary studies of its performance using Monte Carlo simulations and beam test measurements.

  6. Hadron calorimeter module prototype for baryonic matter studies at Nuclotron

    OpenAIRE

    Gavrishchuk, O. P.; Ladygin, V. P.; Petukhov, Yu. P.; Sychkov, S. Ya

    2014-01-01

    The prototype of the hadron calorimeter module consisting of 66 scintillator/lead layers with the 15x15 cm^2 cross section and 5 nuclear interaction lengths has been designed and produced for the zero degree calorimeter of the BM@N experiment. The prototype has been tested with high energy muon beam of the U-70 accelerator at IHEP. The results of the beam test for different types of photo multipliers and light guides are presented. The results of the Monte-Carlo simulation of the calorimeter ...

  7. Development of real-time low energy electron calorimeter

    International Nuclear Information System (INIS)

    A low energy electron beam calorimeter with a thin film window has been fabricated to facilitate a reliable method of dose assessment for electron beam energies down to 200 keV. The system was designed to incorporate a data-logger in order that it could be used on the self-shielded 200 keV facility at MINT. In use, the calorimeter started logging temperature a short time before it passed under the beam and it continued taking data until well after the end of the irradiation. Data could be retrieved at any time after the calorimeter had emerged from the irradiator

  8. Monte Carlo Simulation of HERD Calorimeter

    CERN Document Server

    Xu, M; Dong, Y W; Lu, J G; Quan, Z; Wang, L; Wang, Z G; Wu, B B; Zhang, S N

    2014-01-01

    The High Energy cosmic-Radiation Detection (HERD) facility onboard China's Space Station is planned for operation starting around 2020 for about 10 years. It is designed as a next generation space facility focused on indirect dark matter search, precise cosmic ray spectrum and composition measurements up to the knee energy, and high energy gamma-ray monitoring and survey. The calorimeter plays an essential role in the main scientific objectives of HERD. A 3-D cubic calorimeter filled with high granularity crystals as active material is a very promising choice for the calorimeter. HERD is mainly composed of a 3-D calorimeter (CALO) surrounded by silicon trackers (TK) from all five sides except the bottom. CALO is made of 9261 cubes of LYSO crystals, corresponding to about 55 radiation lengths and 3 nuclear interaction lengths, respectively. Here the simulation results of the performance of CALO with GEANT4 and FLUKA are presented: 1) the total absorption CALO and its absorption depth for precise energy measure...

  9. The pipelined readout for the ZEUS calorimeter

    International Nuclear Information System (INIS)

    The electron-proton storage ring complex HERA under construction at DESY in Hamburg is the first machine of a new generation of colliders. Since physics to be studied at HERA (covered in chapter 2) base on the precise measurement of kinematic variables over a very large range of energies, a foremost emphasis is set in calorimetry. After long studies and an ambitious test program, the ZEUS collaboration has built a high resolution depleted uranium-scintillator calorimeter with photomultiplier readout, the state of the art in detectors of this type. In chapter 3 the principles of calorimetry are reviewed and the construction of the ZEUS calorimeter is described. Mainly due to the large dynamic range and the short bunch crossing times a novel concept for the readout in an analog pipelined fashion had to be designed. This concept is explained in chapter 4. The solid state implementation of the pipeline required two integrated circuits which were developed specially for the ZEUS calorimeter in collaboration with an electronics research institute and produced by industry. The design and construction of these devices and the detailed testing which has been performed for properties critical in the readout is covered in chapters 5 and 6. The whole pipelined readout is a complicated setup with many steps and collaborating systems. Its implementation and the information to operate it are covered in chapter 7. Finally the concepts presented and the applications discussed have been installed and tested on a test beam calibration experiment. There, the modules of the calorimeter have been calibrated. Chapter 8 presents results from these measurements which show excellent performance of the electronics as well as optimal properties of the calorimeter modules. (orig./HSI)

  10. SINERGIA laparoscopic virtual reality simulator: didactic design and technical development.

    Science.gov (United States)

    Lamata, Pablo; Gómez, Enrique J; Sánchez-Margallo, Francisco M; López, Oscar; Monserrat, Carlos; García, Verónica; Alberola, Carlos; Florido, Miguel Angel Rodríguez; Ruiz, Juan; Usón, Jesús

    2007-03-01

    VR laparoscopic simulators have demonstrated its validity in recent studies, and research should be directed towards a high training effectiveness and efficacy. In this direction, an insight into simulators' didactic design and technical development is provided, by describing the methodology followed in the building of the SINERGIA simulator. It departs from a clear analysis of training needs driven by a surgical training curriculum. Existing solutions and validation studies are an important reference for the definition of specifications, which are described with a suitable use of simulation technologies. Five new didactic exercises are proposed to train some of the basic laparoscopic skills. Simulator construction has required existing algorithms and the development of a particle-based biomechanical model, called PARSYS, and a collision handling solution based in a multi-point strategy. The resulting VR laparoscopic simulator includes new exercises and enhanced simulation technologies, and is finding a very good acceptance among surgeons. PMID:17270312

  11. Fermilab Recycler Ring: Technical design report. Revision 1.1

    International Nuclear Information System (INIS)

    This report describes the technical design of the Fermilab Recycler Ring. The purpose of the Recycler is to augment the luminosity increase anticipated from the implementation of the Fermi III upgrade project, which has as its main component the Fermilab Main Injector construction project. The Recycler is a fixed 8 GeV kinetic energy storage ring. It is located in the Main Injector tunnel directly above the Main Injector beamline, near the ceiling. The construction schedule calls for the installation of the Recycler ring before the installation shutdown of the Main Injector. This aggressive construction schedule is made possible by the exclusive use of permanent magnets in the ring lattice, removing the need for expensive conventional iron/copper magnet construction along with the related power supplies, cooling water system, and electrical safety systems. The location, operating energy, and mode of construction are chosen to minimize operational impacts on both Fermilab's ongoing High Energy Physics program and the Main Injector construction project

  12. FERMI(at)Elettra FEL Design Technical Optimization Final Report

    International Nuclear Information System (INIS)

    This is the final report of the FEL Design Group for the Technical Optimization Study for the FERMI(at)ELETTRA project. The FERMI(at)ELETTRA project is based on the principle of harmonic upshifting of an initial ''seed'' signal in a single pass, FEL amplifier employing multiple undulators. There are a number of FEL physics principles which underlie this approach to obtaining short wavelength output: (1) the energy modulation of the electron beam via the resonant interaction with an external laser seed (2) the use of a chromatic dispersive section to then develop a strong density modulation with large harmonic overtones (3) the production of coherent radiation by the microbunched beam in a downstream radiator. Within the context of the FERMI project, we discuss each of these elements in turn

  13. CMS Technical Design Report for the Muon Endcap GEM Upgrade

    CERN Document Server

    Colaleo, A; Sharma, A; Tytgat, M; CERN. Geneva. The LHC experiments Committee; LHCC

    2015-01-01

    This report describes both the technical design and the expected performance of the Phase-II upgrade, using Gas Electron Multiplier (GEM) detectors, of the first endcap station of the CMS muon system. The upgrade is targeted for the second long shutdown of the CERN LHC and is designed to improve the muon trigger and tracking performance at high luminosity. The GEM detectors will add redundancy to the muon system in the 1.6 < |η| < 2.2 pseudorapidity region, where the amount of detection layers is lowest while the background rates are highest and the bending of the muon trajectories due to the CMS magnetic field is small. GEM detectors have been identified as a suitable technology to operate in the high radiation environment present in that region. The first muon endcap station will be instrumented with a double layer of triple-GEM chambers in the 1.6 < |η| < 2.2 region. The detector front-end electronics uses the custom designed VFAT3 chip to provide both fast input for the level-1 muon trigger ...

  14. Testbeam studies of production modules of the ATLAS Tile Calorimeter

    International Nuclear Information System (INIS)

    We report test beam studies of 11% of the production ATLAS Tile Calorimeter modules. The modules were equipped with production front-end electronics and all the calibration systems planned for the final detector. The studies used muon, electron and hadron beams ranging in energy from 3 to 350 GeV. Two independent studies showed that the light yield of the calorimeter was ∼70pe/GeV, exceeding the design goal by 40%. Electron beams provided a calibration of the modules at the electromagnetic energy scale. Over 200 calorimeter cells the variation of the response was 2.4%. The linearity with energy was also measured. Muon beams provided an intercalibration of the response of all calorimeter cells. The response to muons entering in the ATLAS projective geometry showed an RMS variation of 2.5% for 91 measurements over a range of rapidities and modules. The mean response to hadrons of fixed energy had an RMS variation of 1.4% for the modules and projective angles studied. The response to hadrons normalized to incident beam energy showed an 8% increase between 10 and 350 GeV, fully consistent with expectations for a noncompensating calorimeter. The measured energy resolution for hadrons of σ/E=52.9%/√(E)+5.7% was also consistent with expectations. Other auxiliary studies were made of saturation recovery of the readout system, the time resolution of the calorimeter and the performance of the trigger signals from the calorimeter.

  15. Status of the ATLAS Liquid Argon Calorimeter and its Performance

    CERN Document Server

    Barillari, T; The ATLAS collaboration

    2011-01-01

    The ATLAS experiment is designed to study the proton-proton collisions produced at the LHC with a centre-of-mass energy of 14 TeV. Liquid argon (LAr) sampling calorimeters are used in ATLAS for all electromagnetic calorimetry covering the pseudorapidity region |eta|<3.2, as well as for hadronic calorimetry from |eta|=1.4 to |eta|=4.8. The calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic (EMEC), hadronic (HEC) and forward (FCAL) calorimeters. The lead-liquid argon sampling technique with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the endcap (EMEC). This geometry allows a uniform acceptance over the whole azimuthal range without any gap. The hadronic endcap calorimeter (HEC) uses a copper-liquid argon sampling technique with plate geometry and is subdivided into two wheels in depth per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules featuring cylindrical electrodes ...

  16. Liquid Krypton Calorimeter Calibration Software

    CERN Document Server

    Hughes, Christina Lindsay

    2013-01-01

    Calibration of the liquid krypton calorimeter (LKr) of the NA62 experiment is managed by a set of standalone programs, or an online calibration driver. These programs are similar to those used by NA48, but have been updated to utilize classes and translated to C++ while maintaining a common functionality. A set of classes developed to handle communication with hardware was used to develop the three standalone programs as well as the main driver program for online calibration between bursts. The main calibration driver has been designed to respond to run control commands and receive burst data, both transmitted via DIM. In order to facilitate the process of reading in calibration parameters, a serializable class has been introduced, allowing the replacement of standard text files with XML configuration files.

  17. The timing control unit (TCU) and the fan-out (FO) for the DELPHI SAT calorimeter

    International Nuclear Information System (INIS)

    Two specially developed fastbus modules for readout control and monitoring of the SAT calorimeter detector in the DELPHI experiment at CERN are described. The report is intended as a complete technical manual for these modules. 14 refs

  18. The electromagnetic calorimeter in JLab Real Compton Scattering Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Albert Shahinyan; Eugene Chudakov; A. Danagoulian; P. Degtyarenko; K. Egiyan; V. Gorbenko; J. Hines; E. Hovhannisyan; Ch. Hyde; C.W. de Jager; A. Ketikyan; V. Mamyan; R. Michaels; A.M. Nathan; V. Nelyubin; I. Rachek; M. Roedelbrom; A. Petrosyan; R. Pomatsalyuk; V. Popov; J. Segal; Yu. Shestakov; J. Templon; H. Voskanyan; B. Wojtsekhowski

    2007-04-16

    A hodoscope calorimeter comprising of 704 lead-glass blocks is described. The calorimeter was constructed for use in the JLab Real Compton Scattering experiment. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6\\%/$\\sqrt{E_\\gamma \\, [GeV]}$, respectively. Design features and performance parameters during the experiment are presented.

  19. D0 Silicon Upgrade: End Calorimeter Transfer Bridge Modification

    International Nuclear Information System (INIS)

    During the assembly of major components into the D0 Detector, a transfer bridge was required to move the North-End Calorimeter from the clean room,over the cable bridge and onto the north sidewalk of the assembly hall. This experiment is now at the beginning stages of the next phase, namely the upgrade of this Detector for future physics research. A major piece of this upgrade is the installation of a solenoid magnet into the Central Calorimeter. In order to accomplish this, the South End Calorimeter has to be removed from the detector and the North End Calorimeter must be moved an additional 20-inch from its nominal open position (total 60-inch movement). The South End Calorimeter will be removed from the detector using the equipment designed for its installation. The calorimeter will be staged on the south sidewalk during the installation of the solenoid magnet and the central tracking systems. The North End Calorimeter is moved 60-inch to give more space between calorimeters during magnet, tracker and cable installation work. This movement will allow the calorimeter to remain coupled to the cryo system. However, this movement requires an extension be added to the center beam. This extension will support the rear wheels of the calorimeter and in the case of the end calorimeters, carry the majority of the weight. The extension is to be a modification of the transfer bridge. This modification, basically has T1 steel blocks added to one end and legs to the sidewalk supports at the other. The T1 steel blocks are notched to fit into the center beam porches and are welded to bridge rails. This design is the same as that for the installation bridge (3740.312-ME-273456), including the welds and weld procedures which are identical in both cases. Since load testing is impractical, the critical welds will be non-destructive tested by ultrasonic means. The laboratory, through the FESS Department, has a contract with M.Q.S. Inspection Inc. The results of this testing will be

  20. Technical Design Report for the Muon Forward Tracker

    CERN Document Server

    The ALICE Collaboration

    2015-01-01

    The ALICE physics programme after the second LHC Long Shutdown (LS2) is mostly devoted to high precision measurements of hard probes (heavy-flavour hadrons, quarkonia, photons and jets). The strategy for the detector upgrade is reported in the ALICE Upgrade Letter of Intent. The present Technical Design Report describes the Muon Forward Tracker (MFT), a new Si-tracking detector designed to add vertexing capabilities to the MUON spectrometer. The MFT will allow ALICE to extend the precision measurements of the QGP fun- damental properties towards the forward rapidity region. The MFT will sub- stantially improve the present performance of the MUON spectrometer and open the path to new measurements not accessible with the present apparatus (open charm/beauty separation, ψ in central Pb–Pb collisions and J/ψ from b-hadron decays measurements). The MFT consists of two half-cones containing five de- tection half-disks placed along the beams axis between −460 mm and −768 mm away from the average position of ...

  1. Photomultipliers on an LHCb calorimeter

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    An engineer attaches photomultiplier tubes to the electromagnetic calorimeter on the LHCb experiment. These large wall detectors will be used to study the bottom quark, a heavy, short-lived version of quarks found in protons and neutrons. The electromagnetic calorimeter will be used to detect photons, electrons and positrons produced by the decay of these short-lived quarks.

  2. Scintillating fiber ribbon --- tungsten calorimeter

    International Nuclear Information System (INIS)

    We describe an ultra-high density scintillating fiber and tungsten calorimeter used as an active beam-dump for electrons. Data showing the calorimeter response to electrons with momenta between 50 and 350 GeV/c are presented. 9 figs

  3. Design and Delivery of Technical Module for the Business Intelligence Course

    Science.gov (United States)

    Wang, Shouhong; Wang, Hai

    2013-01-01

    IS programs are increasingly being called on to offer courses in business intelligence. This article presents the pedagogical design and the delivery method of a practicable technical module for a non-technically oriented Business Intelligence course. It is a tutorial for the instructors who wish to incorporate a practical technical element in…

  4. Using Problem Based Learning and Game Design to motivate Non-technical Students to engage in Technical Learning

    DEFF Research Database (Denmark)

    Reng, Lars; Schoenau-Fog, Henrik

    2010-01-01

    of Medialogy, we employ problem based learning and game design to engage these students in learning the technical elements. This paper will describe our approach and exemplify the method by introducing various examples of student projects, where the interest in game design combined with problem based learning...

  5. Isothermal calorimeter for reactor radiation dosimetry

    International Nuclear Information System (INIS)

    An isothermal calorimeter with thermistors for measuring absorbed dose rates from 104-5-6.105 rad/h in reactor experimental holes has been designed. A kinetics method for determining the equilibrium temperature difference has been developed, and its application in isothermal calorimetry proved. The expected accuracy in measurements within ± 2-5% has been proved by measurements carried out in the reactor. Some data obtained by measurements in the reactor RA are presented (author)

  6. The CMS Electromagnetic Calorimeter Detector Control System

    International Nuclear Information System (INIS)

    This paper presents the Detector Control System (DCS) designed and implemented for the Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) experiment at CERN. The focus is on its distributed controls software architecture, the deployment of the application into production and its integration into the overall CMS DCS. The knowledge acquired from operational issues during the detector commissioning and the first phase of the Large Hadron Collider (LHC) physics runs is discussed and future improvements are presented.

  7. Electromagnetic response of a highly granular hadronic calorimeter

    International Nuclear Information System (INIS)

    The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described. (orig.)

  8. Electromagnetic response of a highly granular hadronic calorimeter

    CERN Document Server

    Adloff, C; Blaising, J-J; Drancourt, C; Espargilière, A; Gaglione, R; Geffroy, N; Karyotakis, Y; Prast, J; Vouters, G; Francis, K; Repond, J; Smith, J; Xia, L; Baldolemar, E; Li, J; Park, S T; Sosebee, M; White, A P; Yu, J; Mikami, Y; Goto, N K Watson T; Mavromanolakis, G; Thomson, M A; Yan, D R Ward W; Benyamna, M; Cârloganu, C; Fehr, F; Gay, P; Manen, S; Royer, L; Blazey, G C; Dyshkant, A; Lima, J G R; Zutshi, V; Hostachy, J-Y; Morin, L; Cornett, U; David, D; Fabbri, R; Falley, G; Gadow, K; Garutti, E; Göttlicher, P; Günter, C; Karstensen, S; Krivan, F; Lucaci-Timoce, A-I; Lu, S; Lutz, B; Marchesini, I; Meyer, N; Morozov, S; Morgunov, V; Reinecke, M; Sefkow, F; Smirnov, P; Terwort, M; Vargas-Trevino, A; Wattimena, N; Wendt, O; Feege, N; Haller, J; Richter, S; Eckert, J Samson P; Kaplan, A; Schultz-Coulon, H-Ch; Shen, W; Stamen, R; Tadday, A; Bilki, B; Norbeck, E; Onel, Y; Wilson, G W; Kawagoe, K; Uozumi, S; Ballin, J A; Dauncey, P D; Magnan, A -M; Yilmaz, H S; Zorba, O; Bartsch, V; Postranecky, M; Warren, M; Wing, M; Salvatore, F; Alamillo, E Calvo; Fouz, M -C; Puerta-Pelayo, J; Balagura, V; Bobchenko, B; Chadeeva, M; Danilov, M; Epifantsev, A; Markin, O; Mizuk, R; Novikov, E; Rusinov, V; Tarkovsky, E; Soloviev, Y; Kozlov, V; Buzhan, P; Dolgoshein, B; Ilyin, A; Kantserov, V; Kaplin, V; Karakash, A; Popova, E; Smirnov, S; Frey, A; Kiesling, C; Seidel, K; Simon, F; Soldner, C; Weuste, L; Bonis, J; Bouquet, B; Callier, S; Cornebise, P; Doublet, Ph; Dulucq, F; Faucci Giannelli, M; Fleury, J; Guilhem, G; Li, H; Martin-Chassard, G; Richard, F; de la Taille, Ch; Pöschl, R; Raux, L; Seguin-Moreau, N; Wicek, F; Anduze, M; Boudry, V; Brient, J-C; Jeans, D; Mora de Freitas, P; Musat, G; Reinhard, M; Ruan, M; Videau, H; Bulanek, B; Zacek, J; Cvach, J; Gallus, P; Havranek, M; Janata, M; Kvasnicka, J; Lednicky, D; Marcisovsky, M; Polak, I; Popule, J; Tomasek, L; Tomasek, M; Ruzicka, P; Sicho, P; Smolik, J; Vrba, V; Zalesak, J; Belhorma, B; Ghazlane, H; Kotera, K; Nishiyama, M; Takeshita, T; Tozuka, S

    2010-01-01

    The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.

  9. Use of the calorimeter in the dosimetry for electron accelerators

    International Nuclear Information System (INIS)

    The measure of different radiation types, with specific dosemeters, requires that the absorbed dose should be measured with accuracy by some common standard. The existent problem around the dosimetry of accelerated electrons has forced to the development of diverse detector types that after having analyzed the characteristics; dependability and reproducibility are used as dosemeters. Recently the calorimeters have been developed, with the purpose of carrying out dosimetry for electron accelerators. The RISO laboratory in Denmark, in it 10 MeV accelerator had been used for the dosimetry those water calorimeters, later on, using the principle of the water calorimeter, it was designing one similar, for the accelerator of 400 keV. Recently manufactured simple calorimeters of graphite have been used, which can be used in both accelerators of 10 MeV and 400 keV. (Author)

  10. The Forward Calorimeter of the GlueX Experiment

    Science.gov (United States)

    Bennett, Daniel; GlueX Collaboration

    2013-10-01

    The Forward Calorimeter (FCAL) of the GlueX experiment is a lead glass electromagnetic calorimeter currently being built in Hall D of Jefferson Lab. The GlueX experiment is a photoproduction experiment that will utilize coherent bremsstrahlung radiation to map out the light meson spectrum, including a search for hybrid mesons with exotic quantum numbers (JPC). The FCAL will detect photons between 1° and 10 .8° downstream from the target. The calorimeter is built out of 2800 elements, each of which consists of a lead glass block, an FEU 84-3 PMT, and a custom Cockcroft-Walton electronic base. In the Fall of 2011, a 25 element prototype detector was installed in Hall B of Jefferson Lab to measure the energy and timing resolution of the calorimeter using electrons between 100 and 250 MeV. The design and construction of FCAL and the results from the prototype test will be discussed.

  11. Electromagnetic response of a highly granular hadronic calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Adloff, C.; Blaha, J.; Blaising, J.J. [Savoie Univ., CNRS/IN2P3, Annecy-le-Vieux (FR). Lab. d' Annecy-le-Vieux de Physique des Particules] (and others)

    2010-12-15

    The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described. (orig.)

  12. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    Central Calorimeter (HB/HE/HO) Photodetectors The main activity of the HCAL group during the present shutdown is the replacement of a small fraction of the Central Calorimeter (HB/HE/HO) photodetectors -- the Hybrid Photo-Detectors (HPDs). During the MTCC of 2006 it was established that all HPDs exhibit a low rate of discharge generating large random pulses. This behaviour persists at the full CMS field. However, at relatively low fields (0.5 Tesla) this discharge rate increases dramatically and becomes very large for a fraction of the HPDs. The HO HPDs which sit in the gap of the return yoke are thus adversly affected. These discharge pulses have been labelled "HPD noise" (which must be distinguished from low level electronic noise which manifests itself as pedestal noise for all HPD readout channels). Additional intermediate level noise can be generated by ion-feedback arising from thermal and field emission electrons. Ion feedback noise never exceeds the equivalent of few 10s of GeV, the...

  13. Electromagnetic Calorimeter for HADES

    CERN Document Server

    Czyzycki, W; Fabbietti, L; Golubeva, M; Guber, F; Ivashkin, A; Kajetanowicz, M; Krasa, A; Krizek, F; Kugler, A; Lapidus, K; Lisowski, E; Pietraszko, J; Reshetin, A; Salabura, P; Sobolev, Y; Stanislav, J; Tlusty, P; Torrieri, T; Traxler, M

    2011-01-01

    We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton data, but are unknown in the energy range of planned experiments (2-10 GeV per nucleon). The calorimeter will improve the electron-hadron separation, and will be used for detection of photons from strange resonances in elementary and HI reactions. Detailed description of the detector layout, the support structure, the electronic readout and its performance studied via Monte Carlo simulations and series of dedicated test experiments is presented. The device will cover the total area of about 8 m^2 at polar angles between 12 and 45 degrees with almost full azimuthal coverage. The photon and electron energy resolution achieved in test experiments amounts to 5-6%/sqrt(E[GeV]) which is sufficient for the eta meson reconstruction with S/B ratio of 0.4% in Ni+Ni collisions at 8 AGeV....

  14. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    ECAL crystal calorimeter (EB + EE) The Barrel and Endcaps ECAL calorimeters have been used routinely in global runs. The CRAFT data have confirmed that ECAL performance is the same with or without magnetic field. The CRUZET and CRAFT runs have allowed experience to be gained with ECAL operation in many areas, in particular for the trigger and the calibration sequence using gap events (laser events and LED pulsing). More details can be found in the Commissioning/DPG report in this bulletin.   The last components remaining to be installed and commissioned are the specific Endcap Trigger modules (TCC-48). Most of the modules have been delivered to LLR and half of them are already at CERN. In parallel, large progress has been made on the validation of the TCC-48 firmware. Preshower (ES) The Preshower project has also made impressive progress during Autumn. All the elements required to complete the detector assembly are at hand. Ladder assembly, test and calibration with cosmic rays at the operating ...

  15. ELECTROMAGNET CALORIMETER (ECAL)

    CERN Multimedia

    R. Rusack

    Installation is under way of the last piece of the electromagnetic calorimeter. This is the preshower (ES) that sits in front of the two endcap calorimeters. The construction of the ES was completed in December and went through a detailed set of tests in December and January. The two preshower detectors have a total of 4300 silicon sensors with 137,000 strips. After final assembly and system testing in January, only two of the strips were found to be defective. Once CMS was fully opened a new support structure (‘Gazprom’) was put into place underneath the beam pipe, to support the Surkov platform, on which the preshower installation takes place. In the early hours of 26th February the first two Dees, which form the ‘ES+’ endcap,  were transported to P5 , a journey that took two and a half hours. The Dees, still inside environmental protection boxes, were then lowered  underground and moved to the ‘+’ end of CMS. Installation start...

  16. Fermilab Recycler Ring: Technical design report. Revision 1.1

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, G. [ed.

    1996-07-01

    This report describes the technical design of the Fermilab Recycler Ring. The purpose of the Recycler is to augment the luminosity increase anticipated from the implementation of the Fermi III upgrade project, which has as its main component the Fermilab Main Injector construction project. The Recycler is a fixed 8 GeV kinetic energy storage ring. It is located in the Main Injector tunnel directly above the Main Injector beamline, near the ceiling. The construction schedule calls for the installation of the Recycler ring before the installation shutdown of the Main Injector. This aggressive construction schedule is made possible by the exclusive use of permanent magnets in the ring lattice, removing the need for expensive conventional iron/copper magnet construction along with the related power supplies, cooling water system, and electrical safety systems. The location, operating energy, and mode of construction are chosen to minimize operational impacts on both Fermilab`s ongoing High Energy Physics program and the Main Injector construction project.

  17. Determination of shower central position in laterally segmented lead-fluoride electromagnetic calorimeters

    CERN Document Server

    Mazouz, M; Voutier, E

    2015-01-01

    The spatial resolution of laterally segmented electromagnetic calorimeters is studied on the basis of Monte-Carlo simulations worked-out for lead fluoride material. Parametrization of the relative resolution is proposed and optimized in terms of the energy of incoming particles and the elementary size of the calorimeter blocks. A new fit algorithm method is proposed that improves spatial resolution at high energies, and provides guidance for the design optimization of electromagnetic calorimeters.

  18. The presampler for the forward and rear calorimeter in the ZEUS detector

    International Nuclear Information System (INIS)

    The ZEUS detector at HERA has been supplemented with a presampler detector in front of the forward and rear calorimeters. It consists of a segmented scintillator array read out with wavelength-shifting fibers. We discuss its design, construction and performance. Test beam data obtained with a prototype presampler and the ZEUS prototype calorimeter demonstrate the main function of this detector, i.e. the correction for the energy lost by an electron interacting in inactive material in front of the calorimeter. (orig.)

  19. Summary of the liquid argon calorimeter hermeticity working group

    International Nuclear Information System (INIS)

    The cryogenic nature, and hence the need to provide thermal insulation, of liquid argon calorimeters is known to pose serious problems for precise measurements of missing transverse energy, a key signature for new physics at the SSC. This problem is exacerbated by the central detector requirement of access to both sides of the detector. The original DiGiacomo et al. design sought to satisfy this access requirement and still minimize the effect of electromagnetic showers by protruding the end cap calorimeter into the central volume. This design was compared with two design variations by using a parameterization of hadronic and electromagnetic showers assuming no transverse width. These authors concluded that a flat head End Cap design was preferable to the original design for both electromagnetic and hadronic showers. The practical design advantages of this method was further demonstrated by the conclusions that instrumented calorimeter volumes which are not thick enough to absorb most of an electromagnetic shower before a dead volume enhance the resolution degradation. This means, for instance, that calorimeter modules should have their large eta edge on the front face beveled to decrease the effect of the structural washers separating the calorimeter module bays

  20. Design and Implementation of Agro-technical Extension Information System Based on Cloud Storage

    OpenAIRE

    Guo, Leifeng; Wang, Wensheng; Yang, Yong; Sun,Zhiguo

    2013-01-01

    International audience In order to solve the problems of low efficiency and backward methods in the agro-technical extension activities, this paper designed an agro-technical extension information system based on cloud storage technology. This paper studied the key technologies, such as cloud storage service engine, cloud storage management node and cloud storage data node and designed the overall architecture of the agro-technical extension information system based on cloud storage techno...

  1. Muon Detection Based on a Hadronic Calorimeter

    CERN Document Server

    Ciodaro, T; Abreu, R; Achenbach, R; Adragna, P; Aharrouche, M; Aielli, G; Al-Shabibi, A; Aleksandrov, I; Alexandrov, E; Aloisio, A; Alviggi, M G; Amorim, A; Amram, N; Andrei, V; Anduaga, X; Angelaszek, D; Anjos, N; Annovi, A; Antonelli, S; Anulli, F; Apolle, R; Aracena, I; Ask, S; Åsman, B; Avolio, G; Baak, M; Backes, M; Backlund, S; Badescu, E; Baines, J; Ballestrero, S; Banerjee, S; Bansil, H S; Barnett, B M; Bartoldus, R; Bartsch, V; Batraneanu, S; Battaglia, A; Bauss, B; Beauchemin, P; Beck, H P; Bee, C; Begel, M; Behera, P K; Bell, P; Bell, W H; Bellagamba, L; Bellomo, M; Ben Ami, S; Bendel, M; Benhammou, Y; Benslama, K; Berge, D; Bernius, C; Berry, T; Bianco, M; Biglietti, M; Blair, R E; Bogaerts, A; Bohm, C; Boisvert, V; Bold, T; Bondioli, M; Borer, C; Boscherini, D; Bosman, M; Bossini, E; Boveia, A; Bracinik, J; Brandt, A G; Brawn, I P; Brelier, B; Brenner, R; Bressler, S; Brock, R; Brooks, W K; Brown, G; Brunet, S; Bruni, A; Bruni, G; Bucci, F; Buda, S; Burckhart-Chromek, D; Buscher, V; Buttinger, W; Calvet, S; Camarri, P; Campanelli, M; Canale, V; Canelli, F; Capasso, L; Caprini, M; Caracinha, D; Caramarcu, C; Cardarelli, R; Carlino, G; Casadei, D; Casado, M P; Cattani, G; Cerri, A; Cerrito, L; Chapleau, B; Childers, J T; Chiodini, G; Christidi, I; Ciapetti, G; Cimino, D; Ciobotaru, M; Coccaro, A; Cogan, J; Collins, N J; Conde Muino, P; Conidi, C; Conventi, F; Corradi, M; Corso-Radu, A; Coura Torres, R; Cranmer, K; Crescioli, F; Crone, G; Crupi, R; Cuenca Almenar, C; Cummings, J T; Curtis, C J; Czyczula, Z; Dam, M; Damazio, D; Dao, V; Darlea, G L; Davis, A O; De Asmundis, R; De Pedis, D; De Santo, A; de Seixas, J M; Degenhardt, J; Della Pietra, M; Della Volpe, D; Demers, S; Demirkoz, B; Di Ciaccio, A; Di Mattia, A; Di Nardo, R; Di Simone, A; Diaz, M A; Dietzsch, T A; Dionisi, C; Dobson, E; Dobson, M; dos Anjos, A; Dotti, A; Dova, M T; Drake, G; Dufour, M-A; Dumitru, I; Eckweiler, S; Ehrenfeld, W; Eifert, T; Eisenhandler, E; Ellis, K V; Ellis, N; Emeliyanov, D; Enoque Ferreira de Lima, D; Ermoline, Y; Ernst, J; Etzion, E; Falciano, S; Farrington, S; Farthouat, P; Faulkner , P J W; Fedorko, W; Fellmann, D; Feng, E; Ferrag, S; Ferrari, R; Ferrer, M L; Fiorini, L; Fischer, G; Flowerdew, M J; Fonseca Martin, T; Francis, D; Fratina, S; French, S T; Front, D; Fukunaga, C; Gadomski, S; Garelli, N; Garitaonandia Elejabarrieta, H; Gaudio, G; Gee, C N P; George, S; Giagu, S; Giannetti, P; Gillman, A R; Giorgi, M; Giunta, M; Giusti, P; Goebel, M; Gonçalo, R; Gonzalez Silva, L; Göringer, C; Gorini, B; Gorini, E; Grabowska-Bold, I; Green, B; Groll, M; Guida, A; Guler, H; Haas, S; Hadavand, H; Hadley, D R; Haller, J; Hamilton, A; Hanke, P; Hansen, J R; Hasegawa, S; Hasegawa, Y; Hauser, R; Hayakawa, T; Hayden, D; Head, S; Heim, S; Hellman, S; Henke, M; Hershenhorn, A; Hidvégi, A; Hillert, S; Hillier, S J; Hirayama, S; Hod, N; Hoffmann, D; Hong, T M; Hryn'ova, T; Huston, J; Iacobucci, G; Igonkina, O; Ikeno, M; Ilchenko, Y; Ishikawa, A; Ishino, M; Iwasaki, H; Izzo, V; Jez, P; Jimenez Otero, S; Johansen, M; Johns, K; Jones, G; Joos, M; Kadlecik, P; Kajomovitz, E; Kanaya, N; Kanega, F; Kanno, T; Kapliy, A; Kaushik, V; Kawagoe, K; Kawamoto, T; Kazarov, A; Kehoe, R; Kessoku, K; Khomich, A; Khoriauli, G; Kieft, G; Kirk, J; Klemetti, M; Klofver, P; Klous, S; Kluge, E-E; Kobayashi, T; Koeneke, K; Koletsou, I; Koll, J D; Kolos, S; Kono, T; Konoplich, R; Konstantinidis, N; Korcyl, K; Kordas, K; Kotov, V; Kowalewski, R V; Krasznahorkay, A; Kraus, J; Kreisel, A; Kubota, T; Kugel, A; Kunkle, J; Kurashige, H; Kuze, M; Kwee, R; Laforge, B; Landon, M; Lane, J; Lankford, A J; Laranjeira Lima, S M; Larner, A; Leahu, L; Lehmann Miotto, G; Lei, X; Lellouch, D; Levinson, L; Li, S; Liberti, B; Lilley, J N; Linnemann, J T; Lipeles, E; Lohse, T; Losada, M; Lowe, A; Luci, C; Luminari, L; Lundberg, J; Lupu, N; Machado Miguéns, J; Mackeprang, R; Maettig, S; Magnoni, L; Maiani, C; Maltrana, D; Mangeard, P-S; Männer, R; Mapelli, L; Marchese, F; Marino, C; Martin, B; Martin, B T; Martin, T; Martyniuk, A; Marzano, F; Masik, J; Mastrandrea, P; Matsushita, T; McCarn, A; Mechnich, J; Medinnis, M; Meier, K; Melachrinos, C; Mendoza Nava, L M; Merola, L; Messina, A; Meyer, C P; Middleton, R P; Mikenberg, G; Mills, C M; Mincer, A; Mineev, M; Misiejuk, A; Moa, T; Moenig, K; Monk, J; Monticelli, F; Mora Herrera, C; Morettini, P; Morris, J D; Müller, F; Munwes, Y; Murillo Garcia, R; Nagano, K; Nagasaka, Y; Navarro, G A; Negri, A; Nelson, S; Nemethy, P; Neubauer, M S; Neusiedl, A; Newman, P; Nisati, A; Nomoto, H; Nozaki, M; Nozicka, M; Nurse, E; Ochando, C; Ochi, A; Oda, S; Oh, A; Ohm, C; Okumura, Y; Olivito, D; Omachi, C; Osculati, B; Oshita, H; Ospanov, R; Owen, M A; Özcan, V E; Ozone, K; Padilla, C; Panes, B; Panikashvili, N; Paramonov, A; Parodi, F; Pasqualucci, E; Pastore, F; Patricelli, S; Pauly, T; Perera, V J O; Perez, E; Petcu, M; Petersen, B A; Petersen, J; Petrolo, E; Phan, A; Piegaia, R; Pilkington, A; Pinder, A; Poddar, S; Polini, A; Pope, B G; Potter, C T; Primavera, M; Prokoshin, F; Ptacek, E; Qian, W; Quinonez, F; Rajagopalan, S; Ramos Dos Santos Neves, R; Reinherz-Aronis, E; Reinsch, A; Renkel, P; Rescigno, M; Rieke, S; Riu, I; Robertson, S H; Robinson, M; Rodriguez, D; Roich, A; Romeo, G; Romero, R; Roos, L; Ruiz Martinez, A; Ryabov, Y; Ryan, P; Saavedra, A; Safai Tehrani, F; Sakamoto, H; Salamanna, G; Salamon, A; Saland, J; Salnikov, A; Salvatore, F; Sankey, D P C; Santamarina, C; Santonico, R; Sarkisyan-Grinbaum, E; Sasaki, O; Savu, D; Scannicchio, D A; Schäfer, U; Scharf, V L; Scheirich, D; Schiavi, C; Schlereth, J; Schmitt, K; Schroder, C; Schroer, N; Schultz-Coulon, H-C; Schwienhorst, R; Sekhniaidze, G; Sfyrla, A; Shamim, M; Sherman, D; Shimojima, M; Shochet, M; Shooltz, D; Sidoti, A; Silbert, O; Silverstein, S; Sinev, N; Siragusa, G; Sivoklokov, S; Sjoen, R; Sjölin, J; Slagle, K; Sloper, J E; Smith, B C; Soffer, A; Soloviev, I; Spagnolo, S; Spiwoks, R; Staley, R J; Stamen, R; Stancu, S; Steinberg, P; Stelzer, J; Stockton, M C; Straessner, A; Strauss, E A; Strom, D; Su, D; Sugaya, Y; Sugimoto, T; Sushkov, S; Sutton, M R; Suzuki, Y; Taffard, A; Taiblum, N; Takahashi, Y; Takeda, H; Takeshita, T; Tamsett, M; Tan, C L A; Tanaka, S; Tapprogge, S; Tarem, S; Tarem, Z; Taylor, C; Teixeira-Dias, P; Thomas, J P; Thompson, P D; Thomson, M A; Tokushuku, K; Tollefson, K; Tomoto, M; Topfel, C; Torrence, E; Touchard, F; Traynor, D; Tremblet, L; Tricoli, A; Tripiana, M; Triplett, N; True, P; Tsiakiris, M; Tsuno, S; Tuggle, J; Ünel, G; Urquijo, P; Urrejola, P; Usai, G; Vachon, B; Vallecorsa, S; Valsan, L; Vandelli, W; Vari, R; Vaz Gil Lopes, L; Veneziano, S; Ventura, A; Venturi, N; Vercesi, V; Vermeulen, J C; Volpi, G; Vorwerk, V; Wagner, P; Wang, M; Warburton, A; Watkins, P M; Watson, A T; Watson, M; Weber, P; Weidberg, A R; Wengler, T; Werner, P; Werth, M; Wessels, M; White, M; Whiteson, D; Wickens, F J; Wiedenmann, W; Wielers, M; Winklmeier, F; Woods, K S; Wu, S-L; Wu, X; Xaplanteris Karampatsos, L; Xella, S; Yakovlev, A; Yamazaki, Y; Yang, U; Yasu, Y; Yuan, L; Zaitsev, A; Zanello, L; Zhang, H; Zhang, J; Zhao, L; Zobernig, H; zur Nedden, M

    2010-01-01

    The ATLAS Tile hadronic calorimeter (TileCal) provides highly-segmented energy measurements of incoming particles. The information from TileCal's last segmentation layer can assist in muon tagging and it is being considered for a near future upgrade of the level-one trigger, mainly for rejecting triggers due to cavern background at the barrel region. A muon receiver for the TileCal muon signals is being designed in order to interface with the ATLAS level-one trigger. This paper addresses the preliminary studies concerning the muon discrimination capability for the muon receiver. Monte Carlo simulations for single muons from the interaction point were used to study the effectiveness of hadronic calorimeter information on muon detection.

  2. Work on a ATLAS tile calorimeter Barrel

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    The Tile Calorimeter is designed as one barrel and two extended barrel hadron parts. The calorimeter consists of a cylindrical structure with inner and outer radius of 2280 and 4230 mm respectively. The barrel part is 5640 mm in length along the beam axis, while each of the extended barrel cylinders is 2910 mm long. Each detector cylinder is built of 64 independent wedges along the azimuthal direction. Between the barrel and the extended barrels there is a gap of about 600 mm, which is needed for the Inner Detector and the Liquid Argon cables, electronics and services. The barrel covers the region -1.0

  3. Enabling Teachers to Develop Pedagogically Sound and Technically Executable Learning Designs

    NARCIS (Netherlands)

    Miao, Yongwu; Van der Klink, Marcel; Boon, Jo; Sloep, Peter; Koper, Rob

    2008-01-01

    Miao, Y., Van der Klink, M., Boon, J., Sloep, P. B., & Koper, R. (2009). Enabling Teachers to Develop Pedagogically Sound and Technically Executable Learning Designs [Special issue: Learning Design]. Distance Education, 30(2), 259-276.

  4. Calibration boards for the ATLAS LAr calorimeters

    International Nuclear Information System (INIS)

    In order to calibrate the ATLAS Liquid Argon (LAr) calorimeters to an accuracy better than 1%, over 16 bit dynamic range, chips have been designed in DMILL technology. The design and performance of a 16 bit DAC, a static low offset operational amplifier and a digital chip to control the calibration boards are presented. A 8 channels board using these chips has also been realised and carefully measured as this module will be replicated 16 times to design the final 128 channels calibration board. (authors)

  5. Technical Design Study for the PANDA Time Projection Chamber

    CERN Document Server

    Ball, M; Dørheim, S; Höppner, C; Ketzer, B; Konorov, I; Neubert, S; Paul, S; Rauch, J; Uhl, S; Vandenbroucke, M; Berger, M; Berger-Chen, J -C; Cusanno, F; Fabbietti, L; Münzer, R; Arora, R; Frühauf, J; Kiš, M; Leifels, Y; Kleipa, V; Hehner, J; Kunkel, J; Kurz, N; Peters, K; Risch, H; Schmidt, C J; Schmitt, L; Schwab, S; Soyk, D; Voss, B; Weinert, J; Beck, R; Kaiser, D; Lang, M; Schmitz, R; Walther, D; Bühler, P; Müllner, P; Zmeskal, J; Hermann, N

    2012-01-01

    This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.

  6. Design and Implementation of Equipment Interactive Electronic Technical Manuals

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Interactive electronic technical manuals (IETMs) can significantly improve the maintenance and logistics of modern weapon equipment. Main functiors and development strategies of IETMs are discussed. As an example, the IETM development of a certain equipment is demonstrated.

  7. LHCb : First years of running for the LHCb calorimeter system and preparation for run 2

    CERN Multimedia

    Chefdeville, Maximilien

    2015-01-01

    The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). It comprises a calorimeter system composed of four subdetectors: a Scintillating Pad Detector (SPD) and a Pre-Shower detector (PS) in front of an electromagnetic calorimeter (ECAL) which is followed by a hadron calorimeter (HCAL). They are used to select transverse energy hadron, electron and photon candidates for the first trigger level and they provides the identification of electrons, photons and hadrons as well as the measurement of their energies and positions. The calorimeter has been pre-calibrated before its installation in the pit. The calibration techniques have been tested with data taken in 2010 and used regularly during run 1. For run 2, new calibration methods have been devised to follow and correct online the calorimeter detector response. The design and construction characteristics of the LHCb calorimeter will be recalled. Strategies for...

  8. Quality control and calibration of the ZEUS forward and rear calorimeters with 60Co sources

    International Nuclear Information System (INIS)

    We present the motivation for and the design of a mobile 60Co source system used as part of the quality control and calibration monitoring scheme for the ZEUS calorimeters. A 2 mCi 60Co source is pushed by a computer controlled drive mechanism through guide tubes which extend into the calorimeter. Measurements of induced photocurrents as a function of the source position allow checks on the calorimeter response. We present results obtained during the initial scan of all 1024 towers of the forward and rear calorimeter modules. (orig.)

  9. Trigger processing using reconfigurable logic in the CMS calorimeter trigger

    CERN Document Server

    Brooke, J J; Heath, G P; Maddox, A J; Newbold, D; Rabbetts, P D

    2001-01-01

    We present the design of the Global Calorimeter Trigger processor for the CMS detector at LHC. This is a fully pipelined processor system which collects data from all the CMS calorimeters and produces summary information used in forming the Level-1 trigger decision for each event. The design in based on the use of state-of-the-art reconfigurable logic devices (FPGAs) and fast data links. We present the results of device testing using a low-latency pipelined sort algorithm, which demonstrate that an FPGA can be used to perform processing previously foreseen to require custom ASICs. Our design approach results in a powerful, flexible and compact processor system. (0 refs).

  10. Electromagnetic shower detector-calorimeters

    International Nuclear Information System (INIS)

    A brief review of the state-of-the-art of electromagnetic calorimeters is presented. The choice of detector based on the experimental requirements in cost, spatial resolution, energy resolution, and hadron rejection is discussed

  11. Electromagnetic Calorimeter for Hades Experiment

    Science.gov (United States)

    Kugler, A.; Blume, C.; Czyžycki, W.; Epple, E.; Fabbietti, L.; Galatyuk, T.; Golubeva, M.; Guber, F.; Hlaváč, S.; Ivashkin, A.; Kajetanowic, M.; Kardan, B.; Koenig, W.; Lapidus, K.; Lisowski, E.; Pietraszko, J.; Reshetin, A.; Rost, A.; Salabura, P.; Sobolev, Y. G.; Svoboda, O.; Tlusty, P.; Traxler, M.

    2014-06-01

    Electromagnetic calorimeter (ECAL) is being developed to complement the dilepton spectrometer HADES currently operating at GSI Darmstadt, Germany. ECAL will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeV on the beam of future accelerator SIS100@FAIR. The calorimeter will also improve the electron-hadron separation and will as well be used for the detection of photons from strange resonances in elementary and heavy ion reactions. Calorimeter modules constructed of lead glass Cherenkov counter, photomultiplier, HV divider and optical fiber are described in the detail. Two prototypes of novel front-end electronics based on TRB3 are presented. A dedicated LED based system being developed to monitor the stability of the calorimeter during beamtime is introduced as well.

  12. Upgrade of the ATLAS Tile Calorimeter

    CERN Document Server

    Reed, Robert; The ATLAS collaboration

    2014-01-01

    The Tile Calorimeter (TileCal) is the main hadronic calorimeter covering the central region of the ATLAS experiment at LHC. TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC operation (Phase 2 around 2023) where the peak luminosity will increase 5x compared to the design luminosity (10^{34} cm^{-2}s^{-1}) but with maintained energy (i.e. 7+7 TeV). The TileCal upgrade aims to replace the majority of the on- and off-detector electronics so that all calorimeter signals can be digitized and directly sent to the off-detector electronics in the counting room. This will reduce pile-up problems and allow more complex trigger algorithms. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10 Gbps optical links are used to read out all digitized data to t...

  13. The Zeus calorimeter first level trigger

    Energy Technology Data Exchange (ETDEWEB)

    Smith, W.J. [Univ. of Wisconsin, Madison, WI (United States)

    1989-04-01

    The design of the Zeus Detector Calorimeter Level Trigger is presented. The Zeus detector is being built for operation at HERA, a new storage ring that will provide collisions between 820 GeV protons and 30 GeV electrons in 1990. The calorimeter is made of depleted uranium plates and plastic scintillator read out by wavelength shifter bars into 12,864 photomultiplier tubes. These signals are combined into 974 trigger towers with separate electromagnetic and hadronic sums. The calorimeter first level trigger is pipelined with a decision provided 5 {mu}sec after each beam crossing, occurring every 96 nsec. The trigger determines the total energy, the total transverse energy, the missing energy, and the energy and number of isolated electrons and muons. It also provides information on the number and energy of clusters. The trigger rate needs to be held to 1 kHz against a rate of proton-beam gas interactions of approximately 500 kHz. The summed trigger tower pulseheights are digitized by flash ADC`s. The digital values are linearized, stored and used for sums and pattern tests.

  14. Performance of the ATLAS Tile calorimeter

    CERN Document Server

    Bertoli, Gabriele; The ATLAS collaboration

    2015-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment at the LHC is the central hadronic calorimeter designed for energy reconstruction of hadrons, jets, tau­particles and missing transverse energy. TileCal is a scintillator­steel sampling calorimeter and it covers the region of pseudorapidity < 1.7. The scintillation light produced in the tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The analog signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The TileCal front­end electronics read out the signals produced by about 10000 channels measuring energies ranging from ~30 MeV to ~2 TeV. The read­out system is responsible for reconstructing the data in real­time. The digitized signals are reconstructed with the Optimal Filtering algorithm, which computes for each channel the signal amplitude, time and quality factor at the required high rate. Each stage of the signal production from scintillation light to the signal reconstruc...

  15. The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    CERN Document Server

    Adolphsen, Chris; Barish, Barry; Buesser, Karsten; Burrows, Philip; Carwardine, John; Clark, Jeffrey; Durand, Helene Mainaud; Dugan, Gerry; Elsen, Eckhard; Enomoto, Atsushi; Foster, Brian; Fukuda, Shigeki; Gai, Wei; Gastal, Martin; Geng, Rongli; Ginsburg, Camille; Guiducci, Susanna; Harrison, Mike; Hayano, Hitoshi; Kershaw, Keith; Kubo, Kiyoshi; Kuchler, Victor; List, Benno; Liu, Wanming; Michizono, Shinichiro; Nantista, Christopher; Osborne, John; Palmer, Mark; Paterson, James McEwan; Peterson, Thomas; Phinney, Nan; Pierini, Paolo; Ross, Marc; Rubin, David; Seryi, Andrei; Sheppard, John; Solyak, Nikolay; Stapnes, Steinar; Tauchi, Toshiaki; Toge, Nobu; Walker, Nicholas; Yamamoto, Akira; Yokoya, Kaoru

    2013-01-01

    The International Linear Collider Technical Design Report (TDR) describes in four volumes the physics case and the design of a 500 GeV centre-of-mass energy linear electron-positron collider based on superconducting radio-frequency technology using Niobium cavities as the accelerating structures. The accelerator can be extended to 1 TeV and also run as a Higgs factory at around 250 GeV and on the Z0 pole. A comprehensive value estimate of the accelerator is give, together with associated uncertainties. It is shown that no significant technical issues remain to be solved. Once a site is selected and the necessary site-dependent engineering is carried out, construction can begin immediately. The TDR also gives baseline documentation for two high-performance detectors that can share the ILC luminosity by being moved into and out of the beam line in a "push-pull" configuration. These detectors, ILD and SiD, are described in detail. They form the basis for a world-class experimental programme that promises to incr...

  16. Effectuation and its implications for socio-technical design science research in information systems

    OpenAIRE

    Drechsler, Andreas; Hevner, Alan

    2015-01-01

    We study the implications of the effectuation concept for socio-technical artifact design as part of the design science research (DSR) process in information systems (IS). Effectuation logic is the opposite of causal logic. Ef-fectuation does not focus on causes to achieve a particular effect, but on the possibilities that can be achieved with extant means and resources. Viewing so-cio-technical IS DSR through an effectuation lens highlights the possibility to design the future even without s...

  17. Designing Training Interventions: Human or Technical Skills Training?

    Science.gov (United States)

    Petridou, Eugenia N.; Spathis, Charalambos T.

    2001-01-01

    With data from 444 civil service employees, a model was developed to weight individual and occupational characteristics in order to assign employees to interpersonal or technical skills training. Age, gender, education, management level, and job tenure were significant variables associated with each type of training. (Contains 56 references.) (SK)

  18. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    HCAL installation and commissioning is approaching completion. Work continues on commissioning of HE-, HF- and the minus wheels of HO. We expect that all commissioning will be completed by mid-March. HCAL commissioning is interleaved with integration of HCAL and the Global Calorimeter Trigger (GCT). HCAL is attempting to take data using the HPD self-trigger as part of the GCT trigger path. Initial attempts in mid-February have not succeeded. Work continues on HCAL and the GCT. HPD lifetimes at 4 Tesla are being measured in Princeton. After more than a month of testing in a 4 Tesla field there are no sur¬prises. As the lifetime measurements proceed, the HPD response at intermediate fields of 1 Tesla will be verified and analyzed. Work also continues on HCAL calibration and DCS/DSS at Point 5. More details for some of the subsystems are presented in what follows. HE HE plus The cooling system of HE+ is functional now. The HE+ final connections to the LV system are complete. LV and HV tests to ev...

  19. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Spalding

    2011-01-01

    Throughout the entire proton-proton run of 2011, all HCAL calorimeters operated very efficiently. Over 99% of HCAL readout and trigger channels were alive. However, during the year we did face two hardware problems. One major operation problem was the occasional loss of data from a single RBX caused by single event upsets (SEUs). The rate of RBX data loss was on average one incident per 10 pb–1 of integrated luminosity. This led to approximately 1% of CMS data loss. In order to mitigate this problem, HCAL has introduced an automatic reset of the RBX. With this reset, full operation was restored within about one minute. The final hardware correction of the problem will be possible only during a long shutdown (LS1) in 2013-’14. Another hardware problem that developed in 2011 was the failure of QPLL (quartz phase lock loops) chips. This led to the loss of phase of the readout clock with respect to the LHC clock. As a consequence, in two sections in HCAL (10 degree in φ on HB and 1...

  20. Calorimeter Process Variable Archiving

    Energy Technology Data Exchange (ETDEWEB)

    Huffman, David; /Fermilab

    2002-01-14

    These steps were taken to maintain weekly archives: (1) Friday morning you stop the archiver and wait for it to finish writing data (the lock file will be removed from the directory); (2) move the current archive information to a PC via FTP; (3) remove all previous archive information in the previous directory; (4) move the current archive into the previous directory; (5) start a new archive; (6) burn a CDROM of the archive; and (7) copy the current archive to a specific directory. There are 2 ways to check if the Calorimeter Archiver is running, either through the WEB based front end or directly from a command line. Once the archiver is running it can be monitored from a WEB page. This only works with a browser launched from the online machine running the archiver. Each time the browser is reloaded there should be an update reported in the last write check field. You might have to wait a few minutes to see the update. Calorimetry currently takes readings every (300 sec.) 5 minutes. The second method to verify the archiver is running is to issue a command from a Linux cluster machine.

  1. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    D. Green

    The organization of CMS HCAL contains four “geographic” efforts, HB, HO, HE and HF. In addition there are presently five “common” HCAL activities. These ef¬forts are concentrated on electronics, on controls (DCS), on physics objects (JetMet), on Installation and Commissioning (I&C), and on Test Beam (TB) and Cosmic Challenge (MTCC) data taking. HCAL has begun planning to re-organize to be synchronized with the overall CMS management structure. HF The full production of the wedges is completed for some time. The 2004 test beam work has established the radioactive source calibration system for HF works at the 5 % level or better and a note is completed. The calibration of the complete HF is complete. HF is now in the UX cavern and will be hooked up and read out as soon as the services are available. HE The two HE calorimeters are installed and an initial calibration has been established. In the MTCC the HE was read out and muon data was observed. Event b...

  2. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    P. Bloch

    ECAL Barrel (EB) The cabling of the ECAL Barrel services on YB0 was completed early December 2007. The team has now commissioned the complete Barrel. To run all the supermodules in parallel, it is necessary to remove the heat from the service cables on YB0. The corresponding thermal screens are being installed and, for the time being, a max¬imum of 25 supermodules has been run concurrently. EB is read out regularly with a local DAQ as well as with the central DAQ and trigger. The calorimeter trigger has also been commissioned, allowing us to trigger on cosmic muons. ECAL Endcaps (EE) The Endcaps crystal production will be completed before the end of March 2008, as planned. The gluing of the VPTs (Vacuum Photo Triodes) on the crystals and the assembly of Supercrystals (sets of 25 crystals) are proceeding at the pace of 16 Supercrystals (400 channels) per week. Two thirds of the Supercrystals needed for the complete EE have been produced. Their mounting on the Dee backplates (including the connectio...

  3. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    Since the beginning of 2007, HCAL has made significant progress in the installation and commissioning of both hardware and software. A large fraction of the physical Hadron Calorimeter modules have been installed in UX5. In fact, the only missing pieces are HE- and part of HO. The HB+/- were installed in the cryostat in March. HB scintillator layer-17 was installed above ground before the HB were lowered. The HB- scintillator layer-0 was installed immediately after completion of EB- installation. HF/HCAL Commissioning The commissioning and checkout of the HCAL readout electronics is also proceeding at a rapid pace in Bldg. 904 and USC55. All sixteen crates of HCAL VME readout electronics have been commissioned and certified for service. Fifteen are currently operating in the S2 level of USC55. The last crate is being used for firmware development in the Electronics Integration Facility in 904. All installed crates are interfaced to their VME computers and receive synchronous control from the fully-equipp...

  4. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    During the last 3 months commissioning of HCAL has continued for HO and HE+. We have also started the commissioning of the first wedge of HB+. Progress continues to be made by our Trigger/DAQ, DCS and DPG colleagues. HF will be used to obtain a Luminosity measurement for CMS. A first test of the modifications to the HF electronics was made in the August CMS global run. In addition to installation and commissioning of various parts of HCAL, we also completed a very successful summer Test Beam period which saw measurements of the combined HE/EE/ES calorimeter system in the H2 test beam. Installation and Commissioning a. HB commissioning This week, part of the final water-cooling system for HB was commissioned. Eighteen HB- wedges and two pilot wedges on HB+ have been connected to the water circuit on YB0. On Sept 6, 2007 cabling and commissioning was started for the first HB readout box (RBX) using temporary set of cables. We have connected RBX-17 to the Low Voltage PS and the HCAL Detector Control Sy...

  5. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    by J. Spalding and A. Skuja

    2010-01-01

    Operations and Maintenance All HCAL sub-detectors participated throughout the recent data taking with 7 TeV collisions. A timing scan of HF was performed to optimize the timing across the detectors and to set the overall time position of the ~10-ns wide signals within the 25-ns integration time slice. This position was chosen to ensure that the trigger primitives in physics events are generated synchronously at the desired bunch crossing, while also providing discrimination between the calorimeter signals and anomalous signals due to interactions within the photomultiplier tubes. This timing discrimination is now used in the standard filter algorithms for anomalous signals. For HB and HE, once the statistics needed to assess the timing of a sufficient number of channels was accumulated, it was verified that the time settings determined with cosmic, splash events and initial collision data were appropriate for the 7 TeV collision data taking. A further fine-tuning of the HB and HE time settings will be perfo...

  6. Tests of CMS Hadron Forward Calorimeter Upgrade Readout Box Prototype

    CERN Document Server

    Chatrchyan, Sergey; Sirunyan, Albert; Tumasyan, Armen; Mossolov, Vladimir; Shumeiko, Nikolai; Cornelis, Tom; Ochesanu, Silvia; Roland, Benoit Florent; Staykova, Zlatka; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Spilbeeck, Alex; Alves, Gilvan Augusto; Martins, Thiago Dos Reis; Pol, Maria Elena; Vaz Da Silva Filho, Mario; Alda Junior, Walter Luiz; Carvalho, Wagner De Paula; Chinellato, Jose Augusto; De Oliveira Martins, Carley Pedro; Figueiredo, Diego Matos; Tonelli Manganote, Edmilson Jose; Molina Insfran, Jorge Andres; Mundim, Luiz; Nogima, Helio; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Rosa Lopes Zachi, Alessandro; Finger, Miroslav; Finger, Michael; Tsamalaidze, Zviad; Borras, Kerstin; Gunnellini, Paolo; Jung, Hannes; Knutsson, Albert Hans; Lutz, Benjamin; Ribeiro Cipriano, Pedro Miguel; Sen, Niladri; Baus, Colin; Katkov, Igor; Ulrich, Ralf Matthias; Wohrmann, H; Panagiotou, Apostolos; Bencze, Gyorgy; Horvath, D; Bala, Suman; Gupta, Ruchi; Jindal, M; Lal, Manjit Kaur; Nishu, Nishu; Saini, Lovedeep Kaur; Banerjee, Sunanda; Bhattacharya, S; Gomber, Bhawna; Jain, Shilpi; Khurana, Raman; Sharan, Manoj Kumar; Aziz, Tariq; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Katta, Sudhakar; Banerjee, Sudeshna; Dugad, Shashikant Raichand; Etesami, Seyed Mohsen; Fahim, Ali; Jafari, Abideh; Paktinat Mehdiabadi, Saeid; Zeinali, Maryam; Penzo, Aldo; Afanasyev, A; Bunin, Pavel; Ershov, Yuri; Fedoseev, Oleg; Gavrilenko, Mikhail; Golutvin, Igor; Gorbunov, Ilya; Konoplynikov, V; Malakhov, Alexander; Moisenz, Petr; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoly; Andreev, Yuri; Dermenev, Alexander; Krasnikov, Nikolay; Pashenkov, Anatoli; Tlisov, Danila; Toropin, A; Epshteyn, Vladimir; Erofeeva, Maria; Gavrilov, Vladimir; Kosov, Mikhail Vladimirovich; Kudinov, Ilya; Lychkovskaya, Natalia; Popov, V; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlassov, Evgueni; Zhokin, Alexander; Belyaev, A; Boos, Eduard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Klyukhin, Vyacheslav; Kodolova, Olga; Korotkikh, Vladimir; Lokhtin, Igor; Markina, Anastasia; Obraztsov, Stepan; Perfilov, Maxim; Petrushanko, Sergey; Popov, Andrey; Savrin, Victor; Snigirev, Alexander; Vardanyan, Irina; Andreev, V; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Mesyats, Gennady; Vinogradov, Alexey; Bayshev, Igor; Bityukov, Sergey; Grishin, Viatcheslav; Kryshkin, Victor; Petrov, V; Ryutin, Roman; Sobol, Andrey; Turchanovich, Leonid; Troshin, Sergey; Uzunyan, Andrey; Volkov, Alexey; Santanastasio, Francesco; Adiguzel, Aytul; Bakirci, Numan Mustafa; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; G�kbulut, Gul; Gurpinar, Emine; Hos, Ilknur; Kangal, Evrim Ersin; Karapinar, Guler; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Sunar Cerci, Deniz; Tali, Bayram; Topakli, Huseyin; Vergili, Latife Nukhet; Vergili, Mehmet; Aliyev, Takhmasib; Deniz, Muhammed; Guler, Ali Murat; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gulmez, Erhan; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Ozkorucuklu, Suat; Sonmez, Nasuf; Cankocak, Kerem; Levchuk, Leonid; Hatakeyama, Kenichi; Liu, H; Scarborough, Tara Ann; Rumerio, Paolo; Heister, Arno; Hill, C; Lawson, Philip Daniel; Lazic, Dragoslav; Rohlf, James; St. John, Jason; Sulak, Lawrence; Gennadiy, G; Laird, Edward; Landsberg, Greg; Narain, Meenakshi; Sinthuprasith, Tutanon; Tsang, Ka Vang; Long, Owen Rosser; Nguyen, Harold; Paramesvaran, Sudarshan; Sturdy, Jared; Stuart, David; To, Wing; West, Christopher Alan; Apresyan, Artur; Chen, Y; Mott, Alexander Robert; Spiropulu, Maria; Winn, David; Abdoulline, Salavat; Anderson, J; Chlebana, Frank; Freeman, James; Green, Daniel; Hanlon, J; Hirschauer, James Francis; Joshi, Umeshwar; Kunori, Shuichi; Musienko, Yuri; Sharma, Seema; Spalding, William Jeffrey; Tkaczyk, Slawomir; Vidal, Richard; Whitmore, Juliana; Wu, W; Gaultney, Vanessa; Linn, Stephan; Markowitz, Pete Edward; Martinez, German Ruben; Gleyzer, Sergei; Hagopian, Sharon Lee; Hagopian, Vasken; Jenkins, Charles Merrill; Baarmand, Marc M; Dorney, Brian L; Vodopiyanov, Igor; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Clarida, Warren James; Duru, Firdevs; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony Richard; Nachtman, Jane; Newsom, Charles Ray; Norbeck, John Edwin; Olson, Jonathan Edward; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Schmidt, Ianos; Tiras, Emrah; Yetkin, Taylan; Yi, Kai; Kenny, Raymond Patrick; Murray, Michael Joseph; Wood, Jeffrey Scott; Baden, Andrew; Calvert, Brian Michael; Eno, Sarah Catherine; Gomez, Jaime Arturo; Grassi, Tullio; Hadley, Nicholas John; Kellogg, Richard; Kolberg, Ted; Lu, Y; Marionneau, Matthieu; Mignerey, Alice Louise Cox; Peterman, Alison Marie; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite Belt; Kao, Shih-Chuan; Klapoetke, Kevin Humphrey; Mans, Jeremiah Michael; Pastika, Nathaniel Joseph; Kroeger, Robert; Rahmat, Rahmat; Sanders, David; Cremaldi, Lucien Marcus; Jain, S; Anastassov, Anton; Velasco, Mayda Marie; Won, Steven; Heering, Adriaan; Karmgard, Daniel; Pearson, Tessa Jae; Ruchti, Randal; Berry, Edmund A; Halyo, Valerie; Hebda, Philip; Hunt, Adam Paul; Lujan, Paul Joseph; Marlow, Daniel; Medvedeva, Tatiana; Saka, Halil; Tully, Christopher; Zuranski, Andrzej Maciej; Barnes, Virgil Everett; Laasanen, Alvin; Bodek, Arie; Chung, Yeon Sei; de Barbaro, Pawel Jan; Eshaq, Yossof; Garcia-bellido, Aran Angel; Goldenzweig, Pablo David; Han, Ji Yeon; Harel, Amnon; Miner, Daniel Carl; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Ciesielski, Robert Adam; Flanagan, Will Hogan; Kamon, Teruki; Montalvo, Roy Joaquin; Sakuma, Tai; Akchurin, Nural; Damgov, Jordan; Dudero, Phillip Russell; Kovitanggoon, Kittikul; Lee, Sung Won; Libeiro, Terence; Volobouev, Igor; Gurrola, Alfredo; Milstene, Caroline

    2012-01-01

    A readout box prototype for CMS Hadron Forward calorimeter upgrade is built and tested in CERN H2 beamline. The prototype is designed to enable simultaneous tests of different readout options for the four anode upgrade PMTs, new front-end electronics design and new cabling. The response of the PMTs with different readout options is uniform and the background response is minimal. Multi-channel readout options further enhance the background elimination. Passing all the electronics, mechanical and physics tests, the readout box proves to be capable of providing the forward hadron calorimeter operations requirements in the upgrade era.

  7. Engineering prototype of the CALICE analog hadron calorimeter

    International Nuclear Information System (INIS)

    A new prototype of a tile hadron calorimeter (AHCAL) for the International Linear Collider detector is currently developed within the CALICE collaboration. The aim is to improve the energy resolution by measuring details of the shower development and combining them with the data of the tracking chamber (particle flow). The prototype is based on scintillating tiles that are read out by novel Silicon-Photomultiplier (SiPM). This new prototype will take into account all design aspects that are demanded by the intended operation at the ILC It will contain about 2500 detector channels. This is the first calorimeter design which makes full use of the high integration potential of the novel photo-sensor technology. Main focus of this contribution is the mechanical and electrical integration of the front-end electronics into the calorimeter absorber structure, with the aim of maintaining high-density calorimeter. Integration aspects and scalability to an ILC detector are discussed. For the analog calorimeter the proposal of an integrated light-calibration system for calibration and gain monitoring are presented, addressing temperature and bias dependence of the SiPM gain. First results from the measurements with one prototype module at the DESY test beam are presented, which demonstrate the quality of the readout system, and of the light-calibration system.

  8. The lead-glass electromagnetic calorimeter for the SELEX experiment

    International Nuclear Information System (INIS)

    A large-acceptance, highly segmented electromagnetic lead-glass calorimeter for Experiment E781 (SELEX) at Fermi National Acceleration Laboratory was designed and built. This detector has been used to reconstruct photons and electrons with energies ranging from a few GeV up to 500GeV in the collisions of the 600GeV Σ- hyperons, π mesons and protons with the target nucleons. The design, calibration and performance of the calorimeter are described. Energy resolution and position resolution are assessed using both calibration electron beams and π0 mesons reconstructed in 600GeV hadron-hadron interactions. The performance of the calorimeter in selecting resonant states that involve photons is demonstrated

  9. Fractal dimension analysis in a highly granular calorimeter

    CERN Document Server

    Ruan, M; Brient, J.C; Jeans, D; Videau, H

    2015-01-01

    The concept of “particle flow” has been developed to optimise the jet energy resolution by distinguishing the different jet components. A highly granular calorimeter designed for the particle flow algorithm provides an unprecedented level of detail for the reconstruction of calorimeter showers and enables new approaches to shower analysis. In this paper the measurement and use of the fractal dimension of showers is described. The fractal dimension is a characteristic number that measures the global compactness of the shower. It is highly dependent on the primary particle type and energy. Its application in identifying particles and estimating their energy is described in the context of a calorimeter designed for the International Linear Collider.

  10. R&D proposal the prism plastic calorimeter:PPC

    CERN Document Server

    Dobrzynski, Ludwik; Marchand, P; Nédélec, P; Salin, P; CERN. Geneva. Detector Research and Development Committee

    1990-01-01

    This proposal supports two goals: First Goal_Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter (PPC) towers with a new "liquid crystal" type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. Second Goal_ Describe how one can design a warm liquid calorimeter integrated into a LHC detector,and list the advantages of the PPC: low price, minimum of mechanical structures, minimum amount of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronics being outside the liquid and easily accessible, one has maximum flexibility to define them. The R&D program we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  11. Socio-technical Design of Computer-Assisted Work: A discussion of the ETHICS and Tavistock approaches

    OpenAIRE

    Olerup, Agneta

    1989-01-01

    In the paper the major sources of influence on the socio-technical perspective are identified and two socio-technical approaches are compared, namely the Tavistock approach and the ETHICS method developed by Mumford. The Tavistock approach has provided crucial contributions at the work system level, particularly principles for socio-technical design and models for job design (how to design jobs as well as criteria for jobs design). The ETHICS method aims to apply socio-technical thinking to t...

  12. ATLAS high-level trigger, data-acquisition and controls Technical Design Report

    CERN Document Server

    CERN. Geneva. LHC Experiments Committee; Nessi, Marzio; Nordberg, Markus; Smith, Kenway

    2003-01-01

    This Technical Design Report (TDR) for the High-Level-Trigger (HLT), Data Acquisition (DAQ) and Controls of the ATLAS experiment builds on earlier documents published on these systems: Trigger Performance Status Report [1-1], DAQ, EF, LVL2 and DCS Technical Progress Report [1-2], and HLT/DAQ/DCS Technical Proposal [1-3]. Much background and preparatory work relevant to this TDR is referenced in the above documents. In addition, a large amount of detailed technical documentation has been produced in support of this TDR.

  13. Performance evaluation of a commercially available heat flow calorimeter and applicability assessment for safeguarding special nuclear materials

    International Nuclear Information System (INIS)

    The performance characteristics of a commercially available heat-flow calorimeter will be presented. The heat-flow sensors within the calorimeter are based on thermopile technology with a vendor-quoted sensitivity of 150 microV/mW. The calorimeter is a full-twin design to compensate for ambient temperature fluctuations. The efficacy of temperature fluctuation compensations will also be detailed. Finally, an assessment of design applicability to special nuclear materials control and accountability and safeguarding will be presented

  14. Performance evaluation of a commercially available heat flow calorimeter and applicability assessment for safeguarding special nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Bracken, D.S.; Biddle, R.; Rudy, C.

    1998-12-31

    The performance characteristics of a commercially available heat-flow calorimeter will be presented. The heat-flow sensors within the calorimeter are based on thermopile technology with a vendor-quoted sensitivity of 150 {micro}V/mW. The calorimeter is a full-twin design to compensate for ambient temperature fluctuations. The efficacy of temperature fluctuation compensations will also be detailed. Finally, an assessment of design applicability to special nuclear materials control and accountability and safeguarding will be presented.

  15. The data-acquisition and second level trigger system for the ZEUS calorimeter

    International Nuclear Information System (INIS)

    ZEUS and HERA are introduced in chapter 1 with emphasis on the ZEUS Calorimeter and the ZEUS trigger system. The analog and digital electronics developed for the readout of the Calorimeter signals, and the hardware for the Calorimeter Second Level Trigger and data-acquisition system, is described in chapter 2. Emphasis is put on the hardware developed at NIKHEF, which is based on the transputer as the main processing element. The ZEUS trigger and data-acquisition environment as well as the calibration procedures needed for the Calorimeter impose several requirements on the design of the data-acquisition system. The requirements, their implications for the design of the transputer network architecture and the design itself, are described in detail in chapter 3. The software developed for the Calorimeter data-acquisition is described in chapter 4. It includes both the software for the Calorimeter data-acquisition as that required for the calibration of the Calorimeter. First experiences with the CAL-SLT algorithms, obtained during the 1992 HERA running periods, are presented in chapter 5. Chapter 6 discusses the performance of the Calorimeter data-acquisition system. (orig.)

  16. Exploratory shaft facility preliminary designs - Paradox Basin. Technical report

    International Nuclear Information System (INIS)

    The purpose of the Preliminary Design Report, Paradox Basin, is to provide a description of the preliminary design for an Exploratory Shaft Facility in the Paradox Basin, Utah. This issue of the report describes the preliminary design for constructing the exploratory shaft using the Large Hole Drilling Method of construction and outlines the preliminary design and estimates of probable construction cost. The Preliminary Design Report is prepared to complement and summarize other documents that comprise the design at the preliminary stage of completion, December 1982. Other design documents include drawings, cost estimates and schedules. The preliminary design drawing package, which includes the construction schedule drawing, depicts the descriptions in this report. For reference, a list of the drawing titles and corresponding numbers is included in the Appendix. The report is divided into three principal sections: Design Basis, Facility Description, and Construction Cost Estimate. 30 references

  17. Thermal dynamics of bomb calorimeters.

    Science.gov (United States)

    Lyon, Richard E

    2015-12-01

    The thermal dynamics of bomb calorimeters are modeled using a lumped heat transfer analysis in which heat is released in a pressure vessel/bomb immersed in a stirred water bath that is surrounded by a static air space bounded by an insulated (static) jacket, a constant/controlled temperature jacket (isoperibol), or a changing temperature (adiabatic) jacket. The temperature history of the water bath for each of these boundary conditions (methods) is well described by the two-term solution for the calorimeter response to a heat impulse (combustion), allowing the heat transfer coefficients and thermal capacities of the bomb and water bath to be determined parametrically. The validated heat transfer model provides an expression for direct calculation of the heat released in an arbitrary process inside a bomb calorimeter using the temperature history of the water bath for each of the boundary conditions (methods). This result makes possible the direct calculation of the heat of combustion of a sample in an isoperibol calorimeter from the recorded temperature history without the need for semi-empirical temperature corrections to account for non-adiabatic behavior. Another useful result is that the maximum temperature rise of the water bath in the static jacket method is proportional to the total heat generated, and the empirical proportionality constant, which is determined by calibration, accounts for all of the heat losses and thermal lags of the calorimeter. PMID:26724069

  18. COTS Analog Prototype for LHCb's Calorimeter Upgrade

    CERN Document Server

    Abellan Beteta, Carlos; Herms i Berenguer, Atilà

    The objective of this thesis is to present a proposal for the analogue signal processing chain needed for the LHCb calorimeter upgrade improving the design used originally. The design contains several novelties: the system was designed with low noise in mind from the beginning, it is made to have good immunity to interferences stressing the fact that the board will be shared with large digital circuits, differential operational amplifiers are used in a non-standard way as a mean to obtain opposite polarity signals for the signal treatment and a way to increase the available signal in the front end electronics is proposed. The thesis starts with a brief introduction to the detector and its environment. This is followed by an explanation of the use of shapers in high energy physics detectors and the constraints that the shaper must address in the LHCb calorimeter. This leads to a chapter where the circuit design is explained starting from the analysis of the original circuit and its flaws. Once the original cir...

  19. Large aperture calorimeter for fusion laser measurements

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, J.G.; Smith, P.A.

    The authors designed and constructed a large aperture calorimeter intended for laser fusion measurements on beams up to 20 cm diameter. The laser beam is absorbed in a glass disc backed by a disc carry a resistance wire. Although it performs essentially as expected with a noise equivalent energy of 20 mJ and a maximum energy of about 100 J, difficulties in construction give a 17% variation of sensitivity across the aperture. To overcome this problem it would probably be necessary to adopt an integral construction with the resistance bridge formed from an etched film on the back of the absorbing glass.

  20. Test of the ZEUS forward calorimeter prototype

    International Nuclear Information System (INIS)

    Four prototype modules following the same design as the ZEUS forward calorimeter (FCAL) modules have been constructed and tested with electrons, hadrons and muons in the momentum range of 1 to 100 GeV/c. The main topics under investigation were: calibration, uniformity of response, noise, light yield, energy resolution and the electron to hadron response (e/h ratio). The result of the measurements is presented and the expected performance of the FCAL is discussed in the light of these results. (orig.)

  1. Research on calorimeter for high-power microwave measurements

    International Nuclear Information System (INIS)

    Based on measurement of the volume increment of polar liquid that is a result of heating by absorbed microwave energy, two types of calorimeters with coaxial capacitive probes for measurement of high-power microwave energy are designed in this paper. The first is an “inline” calorimeter, which is placed as an absorbing load at the end of the output waveguide, and the second is an “offline” calorimeter that is placed 20 cm away from the radiation horn of the high-power microwave generator. Ethanol and high density polyethylene are used as the absorbing and housing materials, respectively. Results from both simulations and a “cold test” on a 9.3 GHz klystron show that the “inline” calorimeter has a measurement range of more than 100 J and an energy absorption coefficient of 93%, while the experimental results on a 9.3 GHz relativistic backward-wave oscillator show that the device’s power capacity is approximately 0.9 GW. The same experiments were also carried out for the “offline” calorimeter, and the results indicate that it can be used to eliminate the effects of the shock of the solenoid on the measurement curves and that the device has a higher power capacity of 2.5 GW. The results of the numerical simulations, the “cold tests,” and the experiments show good agreement

  2. The E864 lead-scintillating fiber hadronic calorimeter

    International Nuclear Information System (INIS)

    A large hadronic lead scintillating fiber calorimeter has been built and integrated into the AGS experiment E864 [C. Pruneau et al. (1996); F. Rotondo et al. (1996)] spectrometer to provide an independent measurement of the mass of particles produced in heavy ion collisions. The ''''spaghetti-type'''' calorimeter design and construction techniques are described in detail. Results from a prototype and the full implementation of the calorimeter are reported. The hadronic energy resolution of the calorimeter is found to be δE/E=0.035(±0.005)+0.344(±0.008)/√(E/GeV), in very good agreement with a FLUKA calculation. The hadronic time resolution is measured to be better than 400 ps. The combined calorimeter energy and time signals provide for a mass determination with good resolution. The mass resolution scales as δm/m=0.026+0.347/√(E(GeV)) for velocities v/c<0.98. (orig.)

  3. The H1 lead/scintillating-fibre calorimeter

    International Nuclear Information System (INIS)

    The backward region of the H1 detector has been upgraded in order to provide improved measurement of the scattered electron in deep inelastic scattering events. The centerpiece of the upgrade is a high-resolution lead/scintillating-fibre calorimeter. The main design goals of the calorimeter are: good coverage of the region close to the beam pipe, high angular resolution and energy resolution of better than 2% for 30 GeV electrons. The calorimeter should be capable of providing coarse hadronic energy measurement and precise time information to suppress out-of-time background events at the first trigger level. It must be compact due to space restrictions. These requirements were fulfilled by constructing two separate calorimeter sections. The inner electromagnetic section is made of 0.5 mm scintillating plastic fibres embedded in a lead matrix. Its lead-to-fibre ratio is 2.3:1 by volume. The outer hadronic section consists of 1.0 mm diameter fibres with a lead-to-fibre ratio of 3.4:1. The mechanical construction of the new calorimeter and its assembly in the H1 detector are described. (orig.)

  4. ATLAS endcap liquid argon calorimeters. Description and construction of the cryostats

    Energy Technology Data Exchange (ETDEWEB)

    Mace, Guy; Prat, Serge; Veillet, Jean-Jacques [Laboratoire de l' Accelerateur Lineaire IN2P3-CNRS et Universite de Paris-Sud 11, BP 34, F-91898 Orsay Cedex (France)

    2006-05-15

    All forward calorimeters of the ATLAS detector use the same detection technique, energy loss in passive plates, followed by ionisation and charge detection in liquid argon. They are therefore all grouped in the same vessel which must basically support and keep in place the heavy plates and the detection electrodes and maintain liquid argon at cold and stable temperature. Taking into account all the constraints as detailed below, and the overall detector size, 5 meter diameter by 3 meter length this was quite a challenge. The design, construction and tests of these two cryostats, up to their delivery at CERN, are described in this document. These two cryostats are a joint 'in kind' contribution to the Atlas experiment of LAL (Orsay), Max Planck Institute (Muenchen) and Wuppertal University (Wuppertal) and have been designed and built under the responsibility of LAL (Orsay) with contributions of the technical groups of the above institutions and of ATLAS-CERN. (authors)

  5. ATLAS endcap liquid argon calorimeters. Description and construction of the cryostats

    International Nuclear Information System (INIS)

    All forward calorimeters of the ATLAS detector use the same detection technique, energy loss in passive plates, followed by ionisation and charge detection in liquid argon. They are therefore all grouped in the same vessel which must basically support and keep in place the heavy plates and the detection electrodes and maintain liquid argon at cold and stable temperature. Taking into account all the constraints as detailed below, and the overall detector size, 5 meter diameter by 3 meter length this was quite a challenge. The design, construction and tests of these two cryostats, up to their delivery at CERN, are described in this document. These two cryostats are a joint 'in kind' contribution to the Atlas experiment of LAL (Orsay), Max Planck Institute (Muenchen) and Wuppertal University (Wuppertal) and have been designed and built under the responsibility of LAL (Orsay) with contributions of the technical groups of the above institutions and of ATLAS-CERN. (authors)

  6. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  7. The ATLAS liquid Argon calorimeters read-out system

    CERN Document Server

    Blondel, A; Fayard, L; La Marra, D; Léger, A; Matricon, P; Perrot, G; Poggioli, L; Prast, J; Riu, I; Simion, S

    2004-01-01

    The calorimetry of the ATLAS experiment takes advantage of different detectors based on the liquid Argon (LAr) technology. Signals from the LAr calorimeters are processed by various stages before being delivered to the Data Acquisition system. The calorimeter cell signals are received by the front-end boards, which digitize a predetermined number of samples of the bipolar waveform and sends them to the Read-Out Driver (ROD) boards. The ROD board receives triggered data from 1028 calorimeter cells, and determines the precise energy and timing of the signals by processing the discrete samplings of the pulse. In addition, it formats the digital stream for the following elements of the DAQ chain, and performs monitoring. The architecture and functionality of the ATLAS LAr ROD board are discussed, along with the final design of the Processing Unit boards housing the Digital Signal Processors (DSP). (9 refs).

  8. Performance of the PrimEx Electromagnetic Calorimeter

    International Nuclear Information System (INIS)

    We report the design and performance of the hybrid electromagnetic calorimeter consisting of 1152 PbWO4 crystals and 576 lead glass blocks for the PrimEx experiment at the Jefferson Laboratory. The detector was built for high precision measurement of the neutral pion lifetime via the Primakoff effect. Calorimeter installation and commissioning was completed with the first physics run in fall of 2004. We present the energy and position resolution of the calorimeter. Obtained π0 mass resolution of 1.3 MeV/c2 and its production angle resolution of 0.34 mrad demonstrate the ability of the experiment to extract the π0 lifetime on one percent level

  9. Performance of the PrimEx Electromagnetic Calorimeter

    CERN Document Server

    Kubantsev, M; Gasparyan, A

    2006-01-01

    We report the design and performance of the hybrid electromagnetic calorimeter consisting of 1152 $PbWO_4$ crystals and 576 lead glass blocks for the PrimEx experiment at the Jefferson Laboratory. The detector was built for high precision measurement of the neutral pion lifetime via the Primakoff effect. Calorimeter installation and commissioning was completed with the first physics run in fall of 2004. We present the energy and position resolution of the calorimeter. Obtained $\\pi^0$ mass resolution of $1.3 \\mathrm{MeV/c^2}$ and its production angle resolution of $0.34 \\mathrm{mrad}$ demonstrate the ability of the experiment to extract the $\\pi^0$ lifetime on one percent level.

  10. Performance of the PrimEx Electromagnetic Calorimeter

    International Nuclear Information System (INIS)

    We report the design and performance of the hybrid electromagnetic calorimeter consisting of 1152 PbWO4 crystals and 576 lead glass blocks for the PrimEx experiment at the Jefferson Laboratory. The detector was built for high precision measurement of the neutral pion lifetime via the Primakoff effect. Calorimeter installation and commissioning was completed with the first physics run in fall of 2004. We present the energy and position resolution of the calorimeter. Obtained π0 mass resolution of 1.3MeV/c2 and its production angle resolution of 0.34mrad demonstrate the ability of the experiment to extract the π0 lifetime on one percent level

  11. Microgrid Design Toolkit (MDT) Technical Documentation and Component Summaries

    Energy Technology Data Exchange (ETDEWEB)

    Arguello, Bryan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gearhart, Jared Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    The Microgrid Design Toolkit (MDT) is a decision support software tool for microgrid designers to use during the microgrid design process. The models that support the two main capabilities in MDT are described. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new microgrid in the early stages of the design process. MSC is a mixed-integer linear program that is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on refining a microgrid design for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM). TMO uses a genetic algorithm to create and refine a collection of candidate microgrid designs. It uses PRM, a simulation based reliability model, to assess the performance of these designs. TMO produces a collection of microgrid designs that perform well with respect to one or more performance metrics.

  12. Technical Building Design as Practised: A desciption of Typical Tasks

    DEFF Research Database (Denmark)

    Hartvig, Susanne C

    1999-01-01

    The paper reports on a field study perform at a large danish engineering company. Based on empirical studies, 10 distinct design classes are outlined.......The paper reports on a field study perform at a large danish engineering company. Based on empirical studies, 10 distinct design classes are outlined....

  13. Evaluation of technical design of advanced information display(III)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol [Kumoh National Institute of Technology, Gumi (Korea, Republic of); Park, Soon Hyuk [DNT Inc., Daejeon (Korea, Republic of)

    2005-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines.

  14. Evaluation of technical design of advanced information display

    International Nuclear Information System (INIS)

    The performance of human machine system such as nuclear power plant is highly dependent on the suitability of the interface design of the system. As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on CRT or CBP (Computer Based Procedure). This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues as much as possible. The design Issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices

  15. Evaluation of technical design of advanced information display

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae [Kumoh National Institute of Technology, Gumi (Korea, Republic of)

    2003-03-15

    The performance of human machine system such as nuclear power plant is highly dependent on the suitability of the interface design of the system. As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on CRT or CBP (Computer Based Procedure). This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues as much as possible. The design Issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices.

  16. Technical Design Report for the: PANDA Straw Tube Tracker

    CERN Document Server

    Erni, W; Krusche, B; Steinacher, M; Heng, Y; Liu, Z; Liu, H; Shen, X; Wang, Q; Xu, H; Aab, A; Albrecht, M; Becker, J; Csapó, A; Feldbauer, F; Fink, M; Friedel, P; Heinsius, F H; Held, T; Klask, L; Koch, H; Kopf, B; Leiber, S; Leyhe, M; Motzko, C; Pelizäus, M; Pychy, J; Roth, B; Schröder, T; Schulze, J; Sowa, C; Steinke, M; Trifterer, T; Wiedner, U; Zhong, J; Beck, R; Bianco, S; Brinkmann, K T; Hammann, C; Hinterberger, F; Kaiser, D; Kliemt, R; Kube, M; Pitka, A; Quagli, T; Schmidt, C; Schmitz, R; Schnell, R; Thoma, U; Vlasov, P; Walther, D; Wendel, C; Würschig, T; Zaunick, H G; Bianconi, A; Bragadireanu, M; Caprini, M; Pantea, D; Pantelica, D; Pietreanu, D; Serbina, L; Tarta, P D; Kaplan, D; Fiutowski, T; Idzik, M; Mindur, B; Przyborowski, D; Swientek, K; Czech, B; Kistryn, M; Kliczewski, S; Kozela, A; Kulessa, P; Lebiedowicz, P; Pysz, K; Schäfer, W; Siudak, R; Szczurek\\inst, A; Jowzaee, S; Kajetanowicz, M; Kamys, B; Kistryn, S; Korcyl, G; Korcyl, K; Krzemien, W; Magiera, A; Moskal, P; Palka, M; Rudy, Z; Salabura, P; Smyrski, J; Wrońska\\inst, A; Al-Turany, M; Arora, R; Augustin, I; Deppe, H; Flemming, H; Gerhardt, A; Götzen, K; Jordi, A F; Kalicy, G; Karabowicz, R; Lehmann, D; Lewandowski, B; Lühning, J; Maas, F; Orth, H; Patsyuk, M; Peters, K; Saito, T; Schepers, G; Schmidt, C J; Schmitt, L; Schwarz, C; Schwiening, J; Traxler, M; Voss, B; Wieczorek, P; Wilms, A; Zühlsdorf\\inst, M; Abazov, V M; Alexeev, G; Arefiev, A; Astakhov, V I; Barabanov, M Yu; Batyunya, B V; Davydov, Yu I; Dodokhov, V Kh; Efremov, A A; Fedunov, A G; Festchenko, A A; Galoyan, A S; Grigoryan, S; Karmokov, A; Koshurnikov, E K; Lobanov, V I; Lobanov, Yu Yu; Makarov, A F; Malinina, L V; Malyshev, V L; Mustafaev, G A; Olshevskiy, A; Pasyuk, M A; Perevalova, E A; Piskun, A A; Pocheptsov, T A; Pontecorvo, G; Rodionov, V K; Rogov, Yu N; Salmin, R A; Samartsev, A G; Sapozhnikov, M G; Shabratova, G S; Skachkova, A N; Skachkov, N B; Strokovsky, E A; Suleimanov, M K; Teshev, R Sh; Tokmenin, V V; Uzhinsky, V V; Vodopyanov, A S; Zaporozhets, S A; Zhuravlev, N I; Zorin, A G; Branford, D; Glazier, D; Watts, D; Woods, P; Britting, A; Eyrich, W; Lehmann, A; Uhlig, F; Dobbs, S; Metreveli, Z; Seth, K; Tomaradze, A; Xiao, T; Bettoni, D; Carassiti, V; Ramusino, A Cotta; Dalpiaz, P; Drago, A; Fioravanti, E; Garzia, I; Savriè, M; Stancari, G; Bianchi, N; Gianotti, P; Guaraldo, C; Lucherini, V; Orecchini, D; Pace, E; Bersani, A; Bracco, G; Macri, M; Parodi, R F; Bremer, D; Dormenev, V; Drexler, P; Düren, M; Eissner, T; Föhl, K; Galuska, M; Gessler, T; Hayrapetyan, A; Hu, J; Koch, P; Kröck, B; Kühn, W; Lange, S; Liang, Y; Merle, O; Metag, V; Moritz, M; Münchow, D; Nanova, M; Novotny, R; Spruck, B; Stenzel, H; Ullrich, T; Werner, M; Xu, H; Euan, C; Hoek, M; Ireland, D; Keri, T; Montgomery, R; Protopopescu, D; Rosner, G; Seitz, B; Babai, M; Glazenborg-Kluttig, A; Kavatsyuk, M; Lemmens, P; Lindemulder, M; Löhner, H; Messchendorp, J; Moeini, H; Schakel, P; Schreuder, F; Smit, H; Tambave, G; Weele, J C van der; Veenstra\\inst, R; Sohlbach, H; Büscher, M; Deermann, D; Dosdall, R; Esch, S; Gillitzer, A; Goldenbaum, F; Grunwald, D; Henssler, S; Herten, A; Hu, Q; Kemmerling, G; Kleines, H; Kozlov, V; Lehrach, A; Maier, R; Mertens, M; Ohm, H; Orfanitski, S; Prasuhn, D; Randriamalala, T; Ritman, J; Schadmand, S; Serdyuk, V; Sterzenbach, G; Stockmanns, T; Wintz, P; Wüstner, P; Xu, H; Kisiel, J; Li, S; Li, Z; Sun, Z; Xu, H; Rigato, V; Fissum, S; Hansen, K; Isaksson, L; Lundin, M; Schröder, B; Achenbach, P; Bleser, S; Cahit, U; Cardinali, M; Denig, A; Distler, M; Fritsch, M; Kangh, D; Karavdina, A; Lauth, W; Merkel, H; Michel, M; Espi, M C Mora; Müller, U; Pochodzalla, J; Prometeusz, J; Sanchez, S; Sanchez-Lorente, A; Schlimme, S; Sfienti, C; Weber\\inst, M Thiel T; Dormenev, V I; Fedorov, A A; Korzhik, M V; Missevitch, O V; Balanutsa, V; Chernetsky, V; Demekhin, A; Dolgolenko, A; Fedorets, P; Gerasimov, A; Goryachev, V; Varentsov, V; Boukharov, A; Malyshev, O; Marishev, I; Semenov, A; Böhmer, F; Dørheim, S; Ketzer, B; Paul, S; Hergemöller, A K; Khoukaz, A; Köhler, E; Täschner, A; Wessels, J; Varma, R; Chaterjee, A; Jha, V; Kailas, S; Roy, B; Yan, Y; Chinorat, K; Khanchai, K; Ayut, L; Pomrad, S; Baldin, E; Kotov, K; Peleganchuk, S; Tikhonov, Yu; Boucher, J; Chambert, V; Dbeyssi, A; Hennino, T; Imre, M; Kunne, R; Galliard, C Le; Ma, B; Marchand, D; Maroni, A; Ong, S; Ramstein, B; Rosier, P; Sudol, M; Tomasi-Gustafsson, E; Wiele, J Van de; Boca, G; Braghieri, A; Costanza, S; Genova, P; Lavezzi, L; Montagna, P; Rotondi, A; Abramov, V; Belikov, N; Davidenko, A; Derevschikov, A; Goncharenko, Y; Grishin, V; Kachanov, V; Konstantinov, D; Kormilitsin, V; Melnik, Y; Levin, A; Minaev, N; Mochalov, V; Morozov, D; Nogach, L; Poslavskiy, S; Ryazantsev, A; Ryzhikov, S; Semenov, P; Shein, I; Uzunian, A; Vasiliev, A; Yakutin, A; Bäck, T; Cederwall, B; Makónyi, K; Tegnér, P E; Würtemberg, K M von; Belostotski, S; Gavrilov, G; Itzotov, A; Kashchuk, A; Kisselev, A; Kravchenko, P; Levitskaya, O; Manaenkov, S; Miklukho, O; Naryshkin, Y; Veretennikov, D; Vikhrov, V; Zhadanov, A; Alberto, D; Amoroso, A; Bussa, M P; Busso, L; Mori, F De; Destefanis, M; Fava, L; Ferrero, L; Greco, M; Maggiora, M; Marcello, S; Sosio, S; Spataro, S; Zotti, L; Calvo, D; Coli, S; Remigis, P De; Filippi, A; Giraudo, G; Lusso, S; Mazza, G; Morra, O; Rivetti, A; Wheadon, R; Iazzi, F; Lavagno, A; Younis, H; Birsa, R; Bradamante, F; Bressan, A; Martin, A; Clement, H; Galander, B; Balkestal, L Caldeira; Calén, H; Fransson, K; Johansson, T; Kupsc, A; Marciniewski, P; Thomé, E; Wolke, M; Zlomanczuk, J; Díaz, J; Ortiz, A; Dmowski, K; Korzeniewski, R; Przemyslaw, D; Slowinski, B; Chlopik, A; Guzik, Z; Kosinski, K; Melnychuk, D; Wasilewski, A; Wojciechowski, M; Wronka, S; Wysocka, A; Zwieglinski, B; Bühler, P; Hartman, O; Kienle, P; Marton, J; Suzuki, K; Widmann, E; Zmeskal, J

    2012-01-01

    This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole \\Panda scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.

  17. Properties of the avalanche photodiodes for the CMS electromagnetic calorimeter

    International Nuclear Information System (INIS)

    The electromagnetic calorimeter of the CMS experiment at CERN's Large Hadron Collider will use 122 400 Avalanche Photodiodes from Hamamatsu Photonics. The design of this APD type is the result of a long R and D program performed by Hamamatsu Photonics and the CMS collaboration. The APD parameters including the behavior under irradiation are discussed in view of our application

  18. Properties of the avalanche photodiodes for the CMS electromagnetic calorimeter

    CERN Document Server

    Deiters, K; Musienko, Yu V; Nicol, S; Patel, P; Renker, D; Reucroft, S; Rusack, R W; Sakhelashvili, T M; Swain, J D; Vikas, P

    2000-01-01

    The electromagnetic calorimeter of the CMS experiment at CERN's Large Hadron Collider will use 122400 avalanche photodiodes from Hamamatsu Photonics. The design of this APD type is the result of a long R&D program performed by Hamamatsu photonics and the CMS Collaboration. The APD parameters including the behavior under irradiation are discussed in view of our application. (4 refs).

  19. Sandia Laboratories technical capabilities: design, definition, and fabrication

    International Nuclear Information System (INIS)

    This report characterizes the design definition and fabrication capabilities at Sandia Laboratories. Selected applications of these capabilities are presented to illustrate the extent to which they can be applied in research and development programs. 13 figures

  20. Evaluation of technical design of advanced information display(II)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Kang, Young Ju; Ji, Jung Hun; Jang, Sung Pil; Jung, Sung Hae; Park, Hyun Jin [Kumoh National Univ., Gumi (Korea, Republic of)

    2004-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal such as CRT. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices.

  1. Evaluation of technical design of advanced information display(II)

    International Nuclear Information System (INIS)

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal such as CRT. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing information display on CRT by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices

  2. Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype

    CERN Document Server

    Adloff, C; Repond, J; Brandt, A; Brown, H; De, K; Medina, C; Smith, J; Li, J; Sosebee, M; White, A; Yu, J; Buanes, T; Eigen, G; Mikami, Y; Miller, O; Watson, N K; Wilson, J A; Goto, T; Mavromanolakis, G; Thomson, M A; Ward, D R; Yan, W; Benchekroun, D; Hoummada, A; Khoulaki, Y; Oreglia, M; Benyamna, M; Cârloganu, C; Gay, P; Ha, J; Blazey, G C; Chakraborty, D; Dyshkant, A; Francis, K; Hedin, D; Lima, G; Zutshi, V; Babkin, V A; Bazylev, S N; Fedotov, Yu I; Slepnev, V M; Tiapkin, I A; Volgin, S V; Hostachy, J Y; Morin, L; D'Ascenzo, N; Cornett, U; David, D; Fabbri, R; Falley, G; Feege, N; Gadow, K; Garutti, E; Göttlicher, P; Jung, T; Karstensen, S; Korbel, V; Lucaci-Timoce, A I; Lutz, B; Meyer, N; Morgunov, V; Reinecke, M; Schätzel, S; Schmidt, S; Sefkow, F; Smirnov, P; Vargas-Trevino, A; Wattimena, N; Wendt, O; Groll, M; Heuer, R D; Richter, S; Samson, J; Kaplan, A; Schultz-Coulon, H Ch; Shen, W; Tadday, A; Bilki, B; Norbeck, E; Onel, Y; Kim, E J; Kim, G; Kim, D W; Lee, K; Lee, S C; Kawagoe, K; Tamura, Y; Ballin, J A; Dauncey, P D; Magnan, A M; Yilmaz, H; Zorba, O; Bartsch, V; Postranecky, M; Warren, M; Wing, M; Faucci Giannelli, M; Green, M G; Salvatore, F; Kieffer, R; Laktineh, I; Fouz, M C; Bailey, D S; Barlow, R J; Thompson, R J; Batouritski, M; Dvornikov, O; Shulhevich, Yu; Shumeiko, N; Solin, A; Starovoitov, P; Tchekhovski, V; Terletski, A; Bobchenko, B; Chadeeva, M; Danilov, M; Markin, O; Mizuk, R; Morgunov, V; Novikov, E; Rusinov, V; Tarkovsky, E; Andreev, V; Kirikova, N; Komar, A; Kozlov, V; Smirnov, P; Soloviev, Y; Terkulov, A; Buzhan, P; Dolgoshein, B; Ilyin, A; Kantserov, V; Kaplin, V; Karakash, A; Popova, E; Smirnov, S; Baranova, N; Boos, E; Gladilin, L; Karmanov, D; Korolev, M; Merkin, M; Savin, A; Voronin, A; Topkar, A; Freyk, A; Kiesling, C; Lu, S; Prothmann, K; Seidel, K; Simon, F; Soldner, C; Weuste, L; Bouquet, B; Callier, S; Cornebise, P; Dulucq, F; Fleury, J; Li, H; Martin-Chassard, G; Richard, F; de la Taille, Ch; Poeschl, R; Raux, L; Ruan, M; Seguin-Moreau, N; Wicek, F; Anduze, M; Boudry, V; Brient, J C; Gaycken, G; Cornat, R; Jeans, D; Mora de Freitas, P; Musat, G; Reinhard, M; Rougé, A; Vanel, J Ch; Videau, H; Park, K H; Zacek, J; Cvach, J; Gallus, P; Havranek, M; Janata, M; Kvasnicka, J; Marcisovsky, M; Polak, I; Popule, J; Tomasek, L; Tomasek, M; Ruzicka, P; Sicho, P; Smolik, J; Vrba, V; Zalesak, J; Arestov, Yu; Ammosov, V; Chuiko, B; Gapienko, V; Gilitski, Y; Koreshev, V; Semak, A; Sviridov, Yu; Zaets, V; Belhorma, B; Belmir, M; Baird, A; Halsall, R N; Nam, S W; Park, I H; Yang, J; Chai, Jong-Seo; Kim, Jong-Tae; Kim, Geun-Bum; Kim, Y; Kang, J; Kwon, Y J; Kim, Ilgoo; Lee, Taeyun; Park, Jaehong; Sung, Jinho; Itoh, S; Kotera, K; Nishiyama, M; Takeshita, T; Weber, S; Zeitnitz, C

    2010-01-01

    An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.

  3. Construction and commissioning of the CALICE analog hadron calorimeter prototype

    International Nuclear Information System (INIS)

    An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highlysegmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/ monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab. (orig.)

  4. CMS L1 Calorimeter Trigger performance in 2016 data

    CERN Document Server

    CMS Collaboration

    2016-01-01

    After the first long shutdown, the LHC has restarted at a centre-of-mass energy of 13 TeV. The LHC is expected to achieve an instantaneous luminosity larger than $10^{34}$ $\\mathrm{cm}^{-2}\\cdot\\mathrm{s}^{-1}$ and an average number of pile-up interactions of at least 40. The CMS Level-1 trigger architecture has undergone a full upgrade in order to maintain and improve the trigger performance under these new conditions. It will allow CMS to keep the trigger rate under control and to avoid a significant increase in trigger thresholds that would have a negative impact on the CMS physics program. First studies of the performance of the calorimeter trigger upgrade for electrons, photons, tau leptons, jets and energy sums are shown. Details of the algorithms and commissioning may be found in CMS-DP-2015-009, CMS-DP-2015-003, CMS-DP-2015-051 and the CMS Technical Design Report for the Level-1 Trigger upgrade: CERN-LHCC-2013-011, CMS-TDR-12 (2013).

  5. Construction and commissioning of the CALICA analog hadron calorimeter prototype

    Energy Technology Data Exchange (ETDEWEB)

    Adloff, C.; Karyotakis, Y. [Universite de Savoie, Annecy-le-Vieux (France). Laboratoire d' Annecy-le-Vieux de Physique des Particules, CNRS/IN2P3; Repond, J. [Argonne National Laboratory, Argonne, IL (US)] (and others)

    2010-03-15

    An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highlysegmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/ monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab. (orig.)

  6. Analysis of transient and thermostatic behavior of water calorimeter for radiation dosimetry

    International Nuclear Information System (INIS)

    In order to maintain the therapeutic accuracy recommended by the WHO, the American Medical Physics Association has published research results that uncertainty of absorbed dose measurement should be given to less than 3% and many countries are developing the absorbed dose evaluation technique using a calorimeter. Therefore development of water calorimeter and standard measurement method of absorbed dose through the evaluation and ongoing measurement is required in Korea. As an initial step in the development of the water calorimeter by domestic technology, we designed geometry of the phantom and carried out the simulation of the thermal behavior according to the radiation transport and energy deposition by 145TBq KRISS 60Co beam. The results of this study will be used as the basic data for development of the standard water calorimeter in Korea Research Institute of Standards and Science. Through a parallel development and comparison with the graphite calorimeter, this result is expected to be utilized to improve the standard dosimetry

  7. COE1 Calorimeter Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-15

    The purpose of this manual is to describe the operations of the COE1 calorimeter which is used to measure the thermal power generated by the radioactive decay of plutonium-bearing materials for the purposes of assaying the amount of plutonium within the material.

  8. The ZEUS calorimeter first level trigger

    International Nuclear Information System (INIS)

    The design of the ZEUS Calorimeter First Level Trigger (CFLT) is presented. The CFLT utilizes a pipelined architecture to provide trigger data for a global first leel trigger decision 5 μsec after each beam crossing, occurring every 96 nsec. The charges from 13K phototubes are summed into 1792 trigger tower pulseheights which are digitized by flash ADC's. The digital values are linearized, stored and used for sums and pattern tests. Summary data is forwarded to the Global First Level Trigger for each crossing 2 μsec after the crossing occurred. The CFLT determines the total energy, the total transverse energy, the missing energy, and the energy and number of isolated electrons and muons. It also provides information on the electromagnetic and hadronic energy deposited in various regions of the calorimeter. The CFLT has kept the experimental trigger rate below ∼200 Hz at the highest luminosity experienced at HERA. Performance studies suggest that the CFLT will keep the trigger rate below 1 kHZ against a rate of proton-beam gas interactions on the order of the 100 kHz expected at design luminosity. (orig.)

  9. Technical Evaluation Report 49: Learning Objects and Instructional Design

    Directory of Open Access Journals (Sweden)

    Brian Harvey

    2005-07-01

    Full Text Available Reusable learning objects are an approach that is receiving a significant amount of attention in distance-based and online education (see Reports # 11, 40, and 46 in this series. They have the potential to provide cost-effective, personalised instruction with a short development time. Instructional design principles, however, must play an important part in any such development effort, within a design process that occurs on two levels. At the higher level, instruction must be designed to deliver material efficiently to students at the modular/ course/ programme level. Design principles should be applied at the secondary level, at which the unique characteristics of learning objects are determined. Various instructional design (ID methodologies are capable of dealing with these issues. The current report discusses a sle of these methodologies, and compares the ID adequacy of objects in four major learning object repositories: Merlot, CLOE, EOE, and Wisconsin Online. At the time of writing, each of these repositories contains objects that are inadequate from the ID point of view.

  10. The socio-technical design of a library and information science collaboratory

    DEFF Research Database (Denmark)

    Lassi, Monica; Sonnenwald, Diane H.

    2013-01-01

    Introduction. We present a prototype collaboratory, a socio-technical platform to support sharing research data collection instruments in library and information science. No previous collaboratory has attempted to facilitate sharing digital research data collection instruments among library and...... information science researchers.  Method. We have taken a socio-technical approach to design, which includes a review of previous research on collaboratories; an empirical study of specific needs of library and information science researchers; and a use case design method to design the prototype collaboratory...

  11. Technical Training: EMAG-2005 - Electromagnetic Design and Mathematical Optimization Methods in Magnet Technology

    CERN Multimedia

    Monique Duval

    2005-01-01

    CERN Technical Training 2005: Learning for the LHC! CERN Technical Training, in collaboration with the AT-MEL-EM section, is organising a new course series in the framework of the 2005 CERN Technical Training programme: EMAG-2005 - Electromagnetic Design and Mathematical Optimization Methods in Magnet Technology, composed of three-hour lectures in the morning and topical seminars in the afternoon. The EMAG-2005 course series will run at CERN from Monday April 4 until Thursday April 14 (no lectures on Friday 8). The course series, in English, will focus on the foundations of electromagnetism and the design of accelerator magnets, both normal conducting and superconducting, employing analytical and numerical field computations. Examples of the LHC magnet design using the CERN field computation program ROXIE will be presented. However, EMAG-2005 is not a ROXIE user course: it is rather a course for users or potential users of numerical field computation software, and for magnet designers. The course will be o...

  12. Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

    NARCIS (Netherlands)

    Erni, W.; Keshelashvili, I; Krusche, B.

    2009-01-01

    This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modificatio

  13. Work Incentive Simplification Pilot (WISP): Recommendations of the Technical Advisory Panel Regarding the Evaluation Design.

    OpenAIRE

    David Wittenburg; Mann, David R; David C. Stapleton

    2012-01-01

    Still in its early design stages, the Work Incentive Simplification Pilot is a Social Security Administration demonstration to test major simplifications to the Social Security Disability Insurance work incentives. This report presents recommendations from a technical advisory panel, convened by Mathematica and representing the academic, nonprofit, and governmental fields, to provide input on evaluation design options.

  14. Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

    CERN Document Server

    Erni, W; Krusche, B; Steinacher, M; Heng, Y; Liu, Z; Liu, H; Shen, X; Wang, O; Xu, H; Becker, J; Feldbauer, F; Heinsius, F -H; Held, T; Koch, H; Kopf, B; Pelizaeus, M; Schröder, T; Steinke, M; Wiedner, U; Zhong, J; Bianconi, A; Bragadireanu, M; Pantea, D; Tudorache, A; Tudorache, V; De Napoli, M; Giacoppo, F; Raciti, G; Rapisarda, E; Sfienti, C; Bialkowski, E; Budzanowski, A; Czech, B; Kistryn, M; Kliczewski, S; Kozela, A; Kulessa, P; Pysz, K; Schäfer, W; Siudak, R; Szczurek, A; zycki, W Czy; Domagala, M; Hawryluk, M; Lisowski, E; Lisowski, F; Wojnar, L; Gil, D; Hawranek, P; Kamys, B; Kistryn, St; Korcyl, K; Krzemien, W; Magiera, A; Moskal, P; Rudy, Z; Salabura, P; Smyrski, J; Wronska, A; Al-Turany, M; Augustin, I; Deppe, H; Flemming, H; Gerl, J; Goetzen, K; Hohler, R; Lehmann, D; Lewandowski, B; Lühning, J; Maas, F; Mishra, D; Orth, H; Peters, K; Saitô, T; Schepers, G; Schmidt, C J; Schmitt, L; Schwarz, C; Voss, B; Wieczorek, P; Wilms, A; Brinkmann, K -T; Freiesleben, H; Jaekel, R; Kliemt, R; Wuerschig, T; Zaunick, H -G; Abazov, V M; Alexeev, G; Arefev, A; Astakhov, V I; Barabanov, M Yu; Batyunya, B V; Davydov, Yu I; Dodokhov, V Kh; Efremov, A A; Fedunov, A G; Feshchenko, A A; Galoyan, A S; Grigorian, S; Karmokov, A; Koshurnikov, E K; Kudaev, V Ch; Lobanov, V I; Lobanov, Yu Yu; Makarov, A F; Malinina, L V; Malyshev, V L; Mustafaev, G A; Olshevski, A; Pasyuk, M A; Perevalova, E A; Piskun, A A; Pocheptsov, T A; Pontecorvo, G; Rodionov, V K; Rogov, Yu N; Salmin, R A; Samartsev, A G; Sapozhnikov, M G; Shabratova, A; Shabratova, G S; Skachkova, A N; Skachkov, N B; Strokovsky, E A; Suleimanov, M K; Teshev, R Sh; Tokmenin, V V; Uzhinsky, V V; Vodopyanov, A S; Zaporozhets, S A; Zhuravlev, N I; Zorin, A G; Branford, D; Föhl, K; Glazier, D; Watts, D; Woods, P; Eyrich, W; Lehmann, A; Teufel, A; Dobbs, S; Metreveli, Z; Seth, K; Tann, B; Tomaradze, A G; Bettoni, D; Carassiti, V; Cecchi, A; Dalpiaz, P; Fioravanti, E; Garzia, I; Negrini, M; Savri`e, M; Stancari, G; Dulach, B; Gianotti, P; Guaraldo, C; Lucherini, V; Pace, E; Bersani, A; Macri, M; Marinelli, M; Parodi, R F; Brodski, I; Döring, W; Drexler, P; Düren, M; Gagyi-Palffy, Z; Hayrapetyan, A; Kotulla, M; Kühn, W; Lange, S; Liu, M; Metag, V; Nanova, M; Novotny, R; Salz, C; Schneider, J; Schoenmeier, P; Schubert, R; Spataro, S; Stenzel, H; Strackbein, C; Thiel, M; Thoering, U; Yang, S; Clarkson, T; Cowie, E; Downie, E; Hill, G; Hoek, M; Ireland, D; Kaiser, R; Keri, T; Lehmann, I; Livingston, K; Lumsden, S; MacGregor, D; McKinnon, B; Murray, M; Protopopescu, D; Rosner, G; Seitz, B; Yang, G; Babai, M; Biegun, A K; Bubak, A; Guliyev, E; Jothi, V S; Kavatsyuk, M; Löhner, H; Messchendorp, J; Smit, H; van der Weele, J C; García, F; Riska, D -O; Büscher, M; Dosdall, R; Dzhygadlo, R; Gillitzer, A; Grunwald, D; Jha, V; Kemmerling, G; Kleines, H; Lehrach, A; Maier, R; Mertens, M; Ohm, H; Prasuhn, D; Randriamalala, T; Ritman, J; Roeder, M; Stockmanns, T; Wintz, P; Wüstner, P; Kisiel, J; Li, S; Li, Z; Sun, Z; Xu, H; Fissum, S; Hansen, K; Isaksson, L; Lundin, M; Schröder, B; Achenbach, P; Espi, M C Mora; Pochodzalla, J; Sanchez, S; Sanchez-Lorente, A; Dormenev, V I; Fedorov, A A; Korzhik, M V; Missevitch, O V; Balanutsa, V; Chernetsky, V; Demekhin, A; Dolgolenko, A; Fedorets, P; Gerasimov, A; Goryachev, V; Boukharov, A; Malyshev, O; Marishev, I; Semenov, A; Hoeppner, C; Ketzer, B; Konorov, I; Mann, A; Neubert, S; Paul, S; Weitzel, Q; Khoukaz, A; Rausmann, T; Täschner, A; Wessels, J; Varma, R; Baldin, E; Kotov, K; Peleganchuk, S; Tikhonov, Yu; Boucher, J; Hennino, T; Kunne, R; Ong, S; Pouthas, J; Ramstein, B; Rosier, P; Sudol, M; Van de Wiele, J; Zerguerras, T; Dmowski, K; Korzeniewski, R; Przemyslaw, D; Slowinski, B; Boca, G; Braghieri, A; Costanza, S; Fontana, A; Genova, P; Lavezzi, L; Montagna, P; Rotondi, A; Belikov, N I; Davidenko, A M; Derevshchikov, A A; Goncharenko, Yu M; Grishin, V N; Kachanov, V A; Konstantinov, D A; Kormilitsin, V A; Kravtsov, V I; Matulenko, Yu A; Melnik, Y M; Meshchanin, A P; Minaev, N G; Mochalov, V V; Morozov, D A; Nogach, L V; Nurushev, S B; Ryazantsev, A V; Semenov, P A; Soloviev, L F; Uzunian, A V; Vasilev, A N; Yakutin, A E; Baeck, T; Cederwall, B; Bargholtz, C; Geren, L; Tegnér, P E; Belostotskii, S; Gavrilov, G; Itzotov, A; Kiselev, A; Kravchenko, P; Manaenkov, S; Miklukho, O; Naryshkin, Yu; Veretennikov, D; Vikhrov, V; Zhadanov, A; Fava, L; Panzieri, D; Alberto, D; Amoroso, A; Botta, E; Bressani, T; Bufalino, S; Bussa, M P; Busso, L; De Mori, F; Destefanis, M; Ferrero, L; Grasso, A; Greco, M; Kugathasan, T; Maggiora, M; Marcello, S; Serbanut, G; Sosio, S; Bertini, R; Calvo, D; Coli, S; De Remigis, P; Feliciello, A; Filippi, A; Giraudo, G; Mazza, G; Rivetti, A; Szymanska, K; Tosello, F; Wheadon, R; Morra, O; Agnello, M; Iazzi, F; Szymanska, K; Birsa, R; Bradamante, F; Bressan, A; Martin, A

    2009-01-01

    This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.

  15. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Wilkens, H G S; The ATLAS collaboration

    2013-01-01

    The Tile Calorimeter is the central section of the ATLAS hadronic calorimeter. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. Because of its very good signal to noise ratio it is also useful for the identification and reconstruction of muons. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 4900 cells, each viewed by two photomultipliers. The calorimeter response is monitored to better than 1% using radioactive source, laser, and electronic charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of pp collisions acquired in 2011 and 2012. Results on the calorimeter performance are presented, including the absolute energy scale, time resolution, and associated stabilities. In addition to the measurement of the energy and direction of hadronic showers and particles, the calorimeter determines the arriv...

  16. Performance of the ATLAS Tile Calorimeter

    CERN Document Server

    Cole, S; The ATLAS collaboration

    2013-01-01

    The Tile Calorimeter is the central section ($0 < |eta| < 1.7$) of the ATLAS hadronic calorimeter. It is a key detector for the measurement of hadrons, jets, tau leptons decaying hadronically, and missing transverse energy. Because of its very good signal to noise ratio it is also useful for the identification and reconstruction of muons. The calorimeter consists of thin steel plates and 460,000 scintillating tiles configured into 4900 cells, each viewed by two photomultipliers. The calorimeter response is monitored to better than 1% using radioactive source, laser, and electronic charge injection systems. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of pp collisions acquired during 2011 and 2012. Results on the calorimeter performance will be presented, including the absolute energy scale, time resolution, and associated stabilities. These results demonstrate that the Tile Calorimeter is performing...

  17. The socio-technical design of a library and information science collaboratory

    OpenAIRE

    Lassi, Monica; Diane H. Sonnenwald

    2013-01-01

    Introduction. We present a prototype collaboratory, a socio-technical platform to support sharing research data collection instruments in library and information science. No previous collaboratory has attempted to facilitate sharing digital research data collection instruments among library and information science researchers. Method. We have taken a socio-technical approach to design, which includes a review of previous research on collaboratories; an empirical study of specific needs of lib...

  18. Electronics calibration board for the ATLAS liquid argon calorimeters

    International Nuclear Information System (INIS)

    To calibrate the energy response of the ATLAS liquid argon calorimeter, an electronics calibration board has been designed; it delivers a signal whose shape is close to the calorimeter ionization current signal with amplitude up to 100 mA in 50 Ω with 16 bit dynamic range. The amplitude of this signal is designed to be uniform over all calorimeters channels, stable in time and with an integral linearity much better that the electronics readout. The various R and D phases and most of the difficulties met are discussed and illustrated by many measurements. The custom design circuits are described and the layout of the ATLAS calibration board presented. The procedure used to qualify the boards is explained and the performance obtained illustrated: a dynamic range up to 3 TeV in three energy scales with an integral linearity better than 0.1% in each of them, a response uniformity better than 0.2% and a stability better than 0.1%. The performance of the board is well within the ATLAS requirements. Finally, in situ measurements done on the ATLAS calorimeter are shown to validate these performances

  19. CMS Technical Design Report for the Pixel Detector Upgrade

    CERN Document Server

    Dominguez, A; Arndt, K; Bacchetta, N; Ball, A; Bartz, E; Bertl, W; Bilei, G M; Bolla, G; Cheung, H W K; Chertok, M; Costa, S; Demaria, N; Dominguez, A; Ecklund, K; Erdmann, W; Gill, K; Hall, G; Harder, K; Hartmann, F; Horisberger, R; Johns, W; Kaestli, H C; Klein, K; Kotlinski, D; Kwan, S; Pesaresi, M; Postema, H; Rohe, T; Schäfer, C; Starodumov, A; Streuli, S; Tricomi, A; Tropea, P; Troska, J; Vasey, F; Zeuner, W

    2012-01-01

    The original design goal of the LHC was to operate at $1 \\times 10^{34}$ cm$^{−2}s^{−1}$ with 25 ns bunch spacing, where approximately 25 simultaneous inelastic collisions per crossing (“pile-up”) occur. With the upgrade of the accelerators, the lumi- nosity and pile-up will more than double. The current pixel detector is crucial to charged particle tracking, but was not designed to perform effectively in such collision conditions and the physics program of CMS would suffer as a result. We propose to replace the current pixel tracker with a new high efficiency and low mass detector with four barrel layers and three forward/backward disks to provide four-hit pixel coverage out to pseudorapidities of ±2.5. This new detector will meet or exceed the original design specifications in these high luminosity environments. In this report, we provide details on the design, construction and installation of the upgraded pixel detector as well as estimates of its expected performance.

  20. SIAM Conference on Geometric Design and Computing. Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-03-11

    The SIAM Conference on Geometric Design and Computing attracted 164 domestic and international researchers, from academia, industry, and government. It provided a stimulating forum in which to learn about the latest developments, to discuss exciting new research directions, and to forge stronger ties between theory and applications. Final Report

  1. Magnet design technical report---ITER definition phase

    International Nuclear Information System (INIS)

    This report contains papers on the following topics: conceptual design; radiation damage of ITER magnet systems; insulation system of the magnets; critical current density and strain sensitivity; toroidal field coil structural analysis; stress analysis for the ITER central solenoid; and volt-second capabilities and PF magnet configurations

  2. CALIFA, a Dedicated Calorimeter for the R{sup 3}B/FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Cortina-Gil, D., E-mail: d.cortina@usc.es [Universidad de Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Alvarez-Pol, H. [Universidad de Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Aumann, T. [Technische Universität Darmstadt, D-64289 Darmstadt (Germany); Helmholtzzentrum für Schwerionenforschung, D-64291 Darmstadt (Germany); Avdeichikov, V. [University of Lund, SE 221 00 Lund (Sweden); Bendel, M. [Technische Universität München, D-85748 Garching (Germany); Benlliure, J. [Universidad de Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Bertini, D. [Helmholtzzentrum für Schwerionenforschung, D-64291 Darmstadt (Germany); Bezbakh, A. [Joint Institute for Nuclear Research, RU-141980 Dubna (Russian Federation); Bloch, T. [Technische Universität Darmstadt, D-64289 Darmstadt (Germany); Böhmer, M. [Technische Universität München, D-85748 Garching (Germany); Borge, M.J.G.; Briz, J.A. [Instituto Estructura de la Materia, CSIC, E-28006 Madrid (Spain); Cabanelas, P. [Universidad de Santiago de Compostela, E-15782 Santiago de Compostela (Spain); Casarejos, E. [Universidad de Vigo, E-36310 Vigo (Spain); Carmona Gallardo, M. [Instituto Estructura de la Materia, CSIC, E-28006 Madrid (Spain); Cederkäll, J. [University of Lund, SE 221 00 Lund (Sweden); Chulkov, L. [Nuclear Reseach Center, Kurchatov Institute, RU-123182 Moscow (Russian Federation); Dierigl, M. [Technische Universität München, D-85748 Garching (Germany); Di Julio, D. [University of Lund, SE 221 00 Lund (Sweden); Durán, I. [Universidad de Santiago de Compostela, E-15782 Santiago de Compostela (Spain); and others

    2014-06-15

    The R{sup 3}B experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the R{sup 3}B experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction.

  3. CALIFA, a Dedicated Calorimeter for the R3B/FAIR

    International Nuclear Information System (INIS)

    The R3B experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the R3B experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction

  4. Technical Data Exchange Software Tools Adapted to Distributed Microsatellite Design

    Science.gov (United States)

    Pache, Charly

    2002-01-01

    One critical issue concerning distributed design of satellites, is the collaborative work it requires. In particular, the exchange of data between each group responsible for each subsystem can be complex and very time-consuming. The goal of this paper is to present a design collaborative tool, the SSETI Design Model (SDM), specifically developed for enabling satellite distributed design. SDM is actually used in the ongoing Student Space Exploration &Technology (SSETI) initiative (www.sseti.net). SSETI is lead by European Space Agency (ESA) outreach office (http://www.estec.esa.nl/outreach), involving student groups from all over Europe for design, construction and launch of a microsatellite. The first part of this paper presents the current version of the SDM tool, a collection of Microsoft Excel linked worksheets, one for each subsystem. An overview of the project framework/structure is given, explaining the different actors, the flows between them, as well as the different types of data and the links - formulas - between data sets. Unified Modeling Language (UML) diagrams give an overview of the different parts . Then the SDM's functionalities, developed in VBA scripts (Visual Basic for Application), are introduced, as well as the interactive features, user interfaces and administration tools. The second part discusses the capabilities and limitations of SDM current version. Taking into account these capabilities and limitations, the third part outlines the next version of SDM, a web-oriented, database-driven evolution of the current version. This new approach will enable real-time data exchange and processing between the different actors of the mission. Comprehensive UML diagrams will guide the audience through the entire modeling process of such a system. Tradeoffs simulation capabilities, security, reliability, hardware and software issues will also be thoroughly discussed.

  5. The Modern Design of Experiments: A Technical and Marketing Framework

    Science.gov (United States)

    DeLoach, R.

    2000-01-01

    A new wind tunnel testing process under development at NASA Langley Research Center, called Modern Design of Experiments (MDOE), differs from conventional wind tunnel testing techniques on a number of levels. Chief among these is that MDOE focuses on the generation of adequate prediction models rather than high-volume data collection. Some cultural issues attached to this and other distinctions between MDOE and conventional wind tunnel testing are addressed in this paper.

  6. Technical basis for the ITER final design report, cost review and safety analysis (FDR)

    International Nuclear Information System (INIS)

    The ITER final design report, cost review and safety analysis (FDR) is the 4th major milestone, representing the progress made in the ITER Engineering Design Activities. With the approval of the Detailed Design Report (DDR), the design work was concentrated on the requirements of operation, with only relatively minor changes to design concepts of major components. The FDR is the culmination of almost 6 years collaborative design and supporting technical work by the ITER Joint Central Team and Home Teams under the terms of the ITER EDA Agreement

  7. Laser fusion systems design study. Final technical report

    International Nuclear Information System (INIS)

    This study investigated: (1) the formulation and evaluation of an alignment system to accomplish pointing, focusing, centering and translation for the 20-arm SHIVA laser, (2) the formulation and evaluation of concepts for the correction of static phase distortions introduced by the accumulated optical elements in the laser chains, (3) the formulation and evaluation of concepts for the correction of optical path length differences between the arms of the SHIVA system, and (4) the conceptual design of appropriate control system hardware. (U.S.)

  8. The NA48 LKr calorimeter readout electronics

    CERN Document Server

    Gianoli, A; Barr, C; Brodier-Yourstone, P; Buchholz, P; Ceccucci, Augusto; Cerri, C; Chlopik, A; Constantini, F; Fantechi, R; Formenti, F; Funk, W; Giudici, Sergio; Gorini, B; Guzik, J A; Hallgren, Björn I; Kozhevnikov, Yu; Iwansky, W; de La Taille, C; Lacourt, A; Laverrière, G C; Ljuslin, C; Mannelli, I; Martin-Chassard, G; Martini, M; Papi, A; Seguin-Moreau, N; Sozzi, M; Tarlé, J C; Velasco, M; Vossnack, O; Wahl, H; Ziolkowski, M

    2000-01-01

    The NA48 experiment at the CERN SPS accelerator is making a measurement of the direct CP violation parameter epsilon '/ epsilon by comparing the four rates of decay of K/sub S/ and K/sub L/ into 2 pi /sup 0/ and pi /sup +/ pi /sup -/. To reconstruct the decays into 2 pi /sup 0/ the information from the almost 13500 channels of a quasi-homogeneous liquid krypton electromagnetic calorimeter is used. The readout electronics of the calorimeter has been designed to provide a dynamic range from a few MeV to about 50 GeV energy deposition per cell, and to sustain a high rate of incident particles. The system is made by cold charge preamplifiers (working at 120 degrees K), low-noise fast shapers followed by digitizer electronics at 40 MHz sampling rate that employs a gain switching technique to expand the dynamic range, where the gain can be selected for each sample individually (i.e. every 25 ns). To reduce the amount of data collected the system contains a zero suppression circuit based on halo expansion. (12 refs)...

  9. Level-1 Calorimeter Trigger starts firing

    CERN Multimedia

    Stephen Hillier

    2007-01-01

    L1Calo is one of the major components of ATLAS First Level trigger, along with the Muon Trigger and Central Trigger Processor. It forms all of the first-level calorimeter-based triggers, including electron, jet, tau and missing ET. The final system consists of over 250 custom designed 9U VME boards, most containing a dense array of FPGAs or ASICs. It is subdivided into a PreProcessor, which digitises the incoming trigger signals from the Liquid Argon and Tile calorimeters, and two separate processor systems, which perform the physics algorithms. All of these are highly flexible, allowing the possibility to adapt to beam conditions and luminosity. All parts of the system are read out through Read-Out Drivers, which provide monitoring data and Region of Interest (RoI) information for the Level-2 trigger. Production of the modules is now essentially complete, and enough modules exist to populate the full scale system in USA15. Installation is proceeding rapidly - approximately 90% of the final modules are insta...

  10. On the optimization of the energy resolution of hadron calorimeters

    International Nuclear Information System (INIS)

    Measurements on hadron sampling calorimeters are presented. The calorimeters consisted of lead or depleted uranium plates and of scintillator plates of different thicknesses. Design properties which influence the energy resolution were investigated. It is shown that the thickness of absorber- and scintillator plates is a very important parameter. The absorber material and plate thickness leading to the optimum energy resolution of a hadron calorimeter are determined. The measurements on hadron sampling calorimeters show that the energy resolution of such instruments can be optimized if one reduces parts of the strongly fluctuating fraction of nondetectable energy. The hadronic energy resolution of a lead-scintillator calorimeter with a thickness ratio of passive to active absorber of Rd=0.95 is measured to σE/E (h)=41.0%/√E[GeV] +6.1% between 3 and 9 GeV. The e/h-ratio is =1.34 and its deviation from 1 causes the large additive term in the hadronic energy resolution. The energy resolution for hadrons improves for a depleted uranium-scintillator calorimeter of Rd=0.64 to σE/E (h)=29.6%/√E[GeV] +3.2% between 3 and 9 GeV at =1.10. With a depleted uranium-scintillator calorimeter of Rd=2.0 one can achieve overcompensation, i.e. =0.76, at an hadronic energy resolution of σE/E (h)=37.7%/√E[GeV] +3.4% between 5 and 40 GeV. The optimum energy resolution of σE/E (h)=32.9%/√E[GeV] +0.5% between 10 and 100 GeV at =1.00 is achieved for Rd=1.07. Starting from predictions obtained from Monte Carlo calculations, compensation is also achieved with a lead-scintillator calorimeter for Rd=4.0. The measured energy resolution is σE/E (h)=44.2%/√E[GeV] between 3 and 75 GeV at =1.05. (orig.)

  11. Upgrade of the ATLAS Calorimeters for Higher LHC Luminosities

    CERN Document Server

    Carbone, Ryne Michael; The ATLAS collaboration

    2016-01-01

    The upgrade of the LHC will bring instantaneous and total luminosities which are a factor 5-7 beyond the original design of the ATLAS Liquid Argon (LAr) and Tile Calorimeters and their read-out systems. Due to radiation requirements and a new hardware trigger concept the read-out electronics will be improved in two phases. In Phase-I, a dedicated read-out of the LAr Calorimeters will provide higher granularity input to the trigger, in order to mitigate pile-up effects and to reduce the background rates. In Phase-II, completely new read-out electronics will allow a digital processing of all LAr and Tile Calorimeter channels at the full 40 MHz bunch-crossing frequency and a transfer of calibrated energy inputs to the trigger. Results from system design and performance of the developed read-out components, including fully functioning demonstrator systems already operated on the detector, will be reported. Furthermore, the current Forward Calorimeter (FCal) may suffer from signal degradation and argon bubble form...

  12. Construction, calibration and testing of a micro-combustion calorimeter

    International Nuclear Information System (INIS)

    An isoperibolic micro-combustion calorimeter was designed, built and set up in our laboratory, taking as base a 1107 Parr combustion bomb of 22 cm3 of volume. Taken into account the geometrical form of the bomb, it was designed and constructed a vessel and a submarine chamber in brass. All of the pieces of the calorimeter were chromium-plated to reduce heat loss by radiation. The calorimeter was calibrated by using pellets of standard benzoic acid (mass approximate of 40 mg) leading to the energy equivalent of ε(calor) = (1283.8 ± 0.6) J . K-1. In order to test the calorimeter, combustion experiments of salicylic acid were performed leading to a value of combustion energy of Δc u 0 = -(21,888.8 ± 10.9) J . g-1, which agrees with the reported literature values. The combustion of piperonylic acid was carried out as a further test leading to a value of combustion energy of Δc u 0 = -(20,215.9 ± 10.4) J . g-1 in accordance with the reported literature value. The uncertainty of the calibration and the combustion of salicylic acid and piperonylic acid was 0.05%

  13. Upgrade of the ATLAS Calorimeters for Higher LHC Luminosities

    CERN Document Server

    ATLAS Tile Collaboration; The ATLAS collaboration

    2015-01-01

    The upgrade of the LHC will bring instantaneous and total luminosities which are a factor 5-7 beyond the original design of the ATLAS Liquid Argon (LAr) and Tile Calorimeters and their read-out systems. Due to radiation requirements and a new two-level hardware trigger concept the read-out electronics will be improved in two phases. In Phase-I, a dedicated read-out of the LAr Calorimeters will provide higher granularity input to the trigger, in order to mitigate pile-up effects and to reduce the background rates. In Phase-II, completely new read-out electronics will allow a digital processing of all LAr and Tile Calorimeter channels at full 40 MHz bunch-crossing frequency and a transfer of calibrated energy inputs to the trigger. Results from system design and performance of the developed read-out components, including fully functioning demonstrator systems already operated on the detector, will be reported. Furthermore, the current Forward Calorimeter (FCal) may suffer from signal degradation and argon bubbl...

  14. Technical regulations on the general design and safety criteria for design and construction of nuclear reactors of May 1975

    International Nuclear Information System (INIS)

    These Technical Regulations published on 5th September 1975 were made in implementation of Section 33 of Decree No 7/9141 on the procedure for the licensing of nuclear installations. They serve as a guide to licensing authorities, project designers and operators in the nuclear field and therefore provide general criteria for safety standards, engineering codes, siting considerations, design bases for overall environmental radiation protection, and also deal with reactor core design, instrumentation, control, alarm systems, including an emergency core cooling system. Finally, the safe design of fuel elements must be ensured and fuel storage and handling techniques complied with. (NEA)

  15. Thermal Equilibrium Calorimeters -- An Introduction

    CERN Document Server

    McCammon, D

    2005-01-01

    Near-equilibrium thermal detectors operate as classical calorimeters, with energy deposition and internal equilibration times short compared to the thermal time constant of the device. Advances in fabrication techniques, cryogenics, and electronics have made it practical to measure deposited energy with unprecedented sensitivity and precision. In this chapter we discuss performance considerations for these devices, including optimal filtering and energy resolution calculations. We begin with the basic theory of simple equilibrium calorimeters with ideal resistive thermometers. This provides a starting point for a brief discussion of electrothermal feedback, other noise sources, various non-ideal effects, and nonlinearity. We then describe other types of thermometers and show how they fit into this theoretical framework and why they may require different optimizations and figures of merit. Most of this discussion is applicable also to power detectors, or bolometers, where the detector time constants may be sho...

  16. Technical Reviews on Design of Experiment in Process Analytical Technology

    International Nuclear Information System (INIS)

    'Design of experiment (DOE)' provides the information on the relationship between the different factors affecting a experiment and the output of that experiment in a very efficient and accurate way. DOE also can provides the basis for the standard operation procedure of the process, and the selection criteria for raw materials, instruments, and measurement methods by understanding the underlying important variables and by determining the optimum conditions. Since 1970s, DOE has been considered as one of the quality management tools in so-called '6-Sigma', which is adopted actively in many major companies in Korea for the improvement of the all sorts of qualities throughout management, marketing, office, research and development. Process analytical technology (PAT) is a new concept in the field of process analytics proposed by US Food and Drug Administration (US FDA) in Oct. 2002. US FDA encouraged the pharmaceutical industries to implement PAT in the pharmaceutical industry through 'GMPs for the 21st Centry' and the guidance 'PAT - A Framework for Innovative Pharmaceutical Manufacture and Quality Assurance'. PAT has drawn much attention from pharmaceutical industries in response to the US FDA's PAT initiative

  17. Electromagnetic Calorimeter for HADES Experiment

    Directory of Open Access Journals (Sweden)

    Rodríguez-Ramos P.

    2014-01-01

    Full Text Available Electromagnetic calorimeter (ECAL is being developed to complement dilepton spectrometer HADES. ECAL will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 AGeV on the beam of future accelerator SIS100@FAIR. We will report results of the last beam test with quasi-monoenergetic photons carried out in MAMI facility at Johannes Gutenberg Universität Mainz.

  18. Electromagnetic calorimeter for HADES experiment

    Czech Academy of Sciences Publication Activity Database

    Kugler, Andrej; Blume, C.; Czyzycki, W.; Epple, E.; Fabbietti, L.; Galatyuk, T.; Golubeva, M.; Guber, F.; Hlaváč, S.; Ivashkin, A.; Kajetanowicz, M.; Kardan, B.; Koenig, W.; Lapidus, K.; Lisowski, E.; Pietraszko, J.; Reshetin, A.; Rost, A.; Salabura, P.; Sobolev, Yuri, G.; Svoboda, Ondřej; Tlustý, Pavel; Traxler, M.

    Vol. 8. Montreal: World Scientific Publishing Co. Pte. Ltd, 2014, s. 578-582. ISBN 978-981-4603-15-7. [14th International Conference on Advanced Technology and Particle Physics. Como (IT), 23.09.2013-27.09.2013] R&D Projects: GA MŠk LG12007; GA ČR GA13-06759S Institutional support: RVO:61389005 Keywords : HADES collaboration * calorimeter * HADES@FAIR Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  19. Calorimeter based on resistance thermometer

    International Nuclear Information System (INIS)

    The calorimeter on the aluminium alloy basis is developed for the Bremsstrahlung dosimetry. The registration of the absorbed dose is accomplished through the bridge-mounted resistance wire thermometer. It is shown that application of the modern measuring technique makes it possible to register the doses average values from 0.1 Gy, which corresponds to the temperature change in the 10-4 K transducer

  20. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    T. Tabarelli

    2012-01-01

      ECAL has been stably running with an up-time efficiency of 99.4% during Run 2012D, with about half of the inefficiency due to a single downtime episode. More than 99% of the collected data are certified good by ECAL for offline analysis. The monitoring system and calibration chain have also been working smoothly, with an excellent stability of the new laser source, after final tuning during the technical stop in September. Some drifts in the response upon monitoring corrections and some degradation in the resolution throughout Run 2012C and 2012D have been observed and will be corrected in the next reprocessing. Calibration constants for the full 2012 dataset –– derived with well-established procedures –– are going to be delivered by the end of the pp run. In parallel to this, studies of the performance evolution have been carried out to predict the longevity of ECAL towards HL-LHC. Radiation damage effects are studied from P5 data, particularly in the end...

  1. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    2011-01-01

    All components of ECAL – EB, EE and ES – operated well throughout 2010 with few problems, and negligible evolution of dead channels. About 2% of the ES silicon sensors were unplugged in the second part of the year due to unacceptable increases in leakage currents attributed to radiation damage of the surfaces. The LHC winter technical stop allowed many improvements to the ECAL infrastructure at Point 5. For example, the High Voltage distribution systems for the EE and ES were both improved, with further modifications planned for the ES later in the year. Monitoring and alarming of power supplies was also improved, increasing the level of safety. Some cables in the USC and UXC were re-worked, recovering the operation of some environmental monitoring sensors and improving robustness overall. A thorough Readiness Review Workshop was organised at the end of January 2011 to review 2010 data quality and online and offline operations, and to prepare for the higher luminosities in 2011. All prese...

  2. ELECTROMAGNETIC CALORIMETER (ECAL)

    CERN Multimedia

    T. Tabarelli

    2011-01-01

    All components of ECAL have been running smoothly throughout the 2011 run; the general health of the system is stable since 2010, with close to 99% of the channels available for energy reconstruction. Less than 3% of the registered luminosity to date has bad data quality in ECAL. About 2/3 of the data lost were affected by a low-voltage (LV) failure in one EB super-module due to a flaky contact. After prompt repair, all the remaining contacts were thoroughly checked in the late-March technical stop, with some additional repairs being carried-out. After extensive tests in late 2010 and further optimisation with first 2011 collisions, the rejection at L1 of anomalous signals ascribed to the nuclear counter effect in the APDs is now incorporated in standard running. The required factor-of-3 reduction in the lowest un-prescaled electron/photon trigger (EG12) was met, with larger reduction factors for higher transverse energies, as expected. Studies are ongoing to anticipate the anomalous signal rejection perform...

  3. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    J. Mans and P. De Barbaro

    2012-01-01

      During the year-end technical stop, HCAL has successfully undertaken a number of efforts in the detector and calibration areas. The full online software suite has been modernised to the next generation of Scientific Linux and 64-bit computing. In HF, a full set of 24 thin-window phototubes from the production set has been installed to allow further study of background rates as well as to evaluate the behaviour of the tubes under irradiation. The optical data fibres from two wedges of HB and an equivalent portion of HE and HF have been split, allowing the parallel operation of upgrade backend electronics without affecting the ongoing operations of the VME electronics. The HCAL DPG group has prepared the software and calibration for the restart at 8 TeV. The reconstruction and noise rejection have been tuned for higher pile-up conditions, while the final calibrations for HF will be used for a final re-reconstruction of the 2011 data as well as for the 2012 start-up. The DPG group is prepared for ...

  4. Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype

    CERN Document Server

    Adloff, C; Repond, J; Yu, J; Eigen, G; Mikami, Y; Watson, N K; Wilson, J A; Goto, T; Mavromanolakis, G; Thomson, M A; Ward, D R; Yan, W; Benchekroun, D; Hoummada, A; Khoulaki, Y; Apostolakis, J; Ribon, A; Uzhinskiy, V; Benyamna, M; Carloganu, C; Fehr, F; Gay, P; Blazey, G C; Chakraborty, D; Dyshkant, A; Francis, K; Hedin, D; Lima, J G; Zutshi, V; Hostachy, J Y; Krastev, K; Morin, L; D'Ascenzo, N; Cornett, U; David, D; Fabbri, R; Falley, G; Gadow, K; Garutti, E; Gottlicher, P; Jung, T; Karstensen, S; Lucaci-Timoce, A I; Lutz, B; Meyer, N; Morgunov, V; Reinecke, M; Sefkow, F; Smirnov, P; Vargas-Trevino, A; Wattimena, N; Wendt, O; Feege, N; Groll, M; Haller, J; Heuer, R D; Morozov, S; Richter, S; Samson, J; Kaplan, A; Schultz-Coulon, H C; Shen, W; Tadday, A; Bilki, B; Norbeck, E; Onel, Y; Kim, E J; Kim, G; Kim, D W; Lee, K; Lee, S C; Kawagoe, K; Tamura, Y; Dauncey, P D; Magnan, A M; Yilmaz, H; Zorba, O; Bartsch, V; Postranecky, M; Warren, M; Wing, M; Green, M G; Salvatore, F; Bedjidian, M; Kieffer, R; Laktineh, I; Fouz, M C; Bailey, D S; Barlow, R J; Kelly, M; Thompson, R J; Danilov, M; Tarkovsky, E; Baranova, N; Karmanov, D; Korolev, M; Merkin, M; Voronin, A; Frey, A; Lu, S; Seidel, K; Simon, F; Soldner, C; Weuste, L; Bonis, J; Bouquet, B; Callier, S; Cornebise, P; Doublet, Ph; Faucci Giannelli, M; Fleury, J; Li, H; Martin-Chassard, G; Richard, F; de la Taille, Ch; Poeschl, R; Raux, L; Seguin-Moreau, N; Wicek, F; Anduze, M; Boudry, V; Brient, J C; Gaycken, G; Jeans, D; Mora de Freitas, P; Musat, G; Reinhard, M; Rouge, A; Ruan, M; Vanel, J C; Videau, H; Park, K H; Zacek, J; Cvach, J; Gallus, P; Havranek, M; Janata, M; Marcisovsky, M; Polak, I; Popule, J; Tomasek, L; Tomasek, M; Ruzicka, P; Sicho, P; Smolik, J; Vrba, V; Zalesak, J; Belhorma, B; Belmir, M; Nam, S W; Park, I H; Yang, J; Chai, J S; Kim, J T; Kim, G B; Kang, J; Kwon, Y J

    2010-01-01

    A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.

  5. Operation of the enhanced ATLAS First Level Calorimeter Trigger at the start of Run-2

    CERN Document Server

    Palka, Marek; The ATLAS collaboration

    2015-01-01

    In 2015 the LHC will operate with a higher center-of-mass energy and proton beams luminosity. To keep a high trigger efficiency against an increased event rate, part of ATLAS Level-1 Calorimeter Trigger electronics have been re-designed or newly introduced (Pre-Processors, Merging Modules and Topological Processors). Additionally, to achieve the best possible resolution for the reconstructed physics objects, complex calibration and monitoring systems are employed. Hit rates and energy spectra down to channel level, based on reconstructed events, are supervised with the calorimeter trigger hardware. The performance of the upgraded Level-1 Calorimeter Trigger at the beginning of LHC Run-2 is illustrated.

  6. Radiation hard micro-coaxial cables for the ATLAS liquid argon calorimeters

    CERN Document Server

    Bonivento, W; Imbert, P; de La Taille, C

    2000-01-01

    The ATLAS collaboration has chosen for the electromagnetic barrel calorimeter and for all the end-cap calorimeters a sampling technique, with liquid argon as the active medium. The read-out electronics and the calibration pulsers are located in boxes outside the cryostats housing the detectors. Signals are transmitted between the detectors and the electronic boxes through custom-designed micro- coaxial cables, which are the subject of this paper. These cables have to satisfy very stringent tolerances in terms of signal transmission, dimensions and radiation hardness. Following a successful pre-series production, these cables have been selected for equipping the ATLAS calorimeter. (16 refs).

  7. Rethinking Effective Teaching and Learning for the Design of Efficient Curriculum for Technical Teachers

    Directory of Open Access Journals (Sweden)

    Tiia Rüütmann

    2013-01-01

    Full Text Available Technical teachers need to possess skills in at least two distinct areas: engineering discipline and the art of teaching, balancing these two areas, knowing in-action how to do it in real-life situations and for real professional purposes. Understanding student individualities and their different learning styles is one of the midpoints of teacher training. The newly designed curriculum for technical teachers makes scientifically-founded and practice-oriented teacher training possible. The aim of the study programme described is to abolish mismatches between common learning styles and traditional teaching styles. The implementation of the designed curriculum concentrates on interactive lectures and inductive teaching model. Contemporary teaching models and strategies motivate students to learn more effectively, providing future technical teachers with teaching techniques which address all learning styles.

  8. The MiniBooNE detector technical design report

    Energy Technology Data Exchange (ETDEWEB)

    I. Stancu et al.

    2003-04-18

    The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in Fig. 1.2 if oscillations are observed; and test CP conservation in the lepton sector if oscillations are observed by running with separate {nu}{sub {mu}} and {bar {nu}}{sub {mu}} beams. The detector will consist of a spherical tank 6.1 m (20 feet) in radius, as shown in Fig. 1.3, that stands in a 45-foot diameter cylindrical vault. An inner tank structure at 5.75 m radius will support 1280 8-inch phototubes (10% coverage) pointed inward and optically isolated from the outer region of the tank. The tank will be filled with 807 t of mineral oil, resulting in a 445 t fiducial volume. The outer tank volume will serve as a veto shield for identifying particles both entering and leaving the detector with 240 phototubes mounted on the tank wall. Above the detector tank will be an electronics enclosure that houses the fast electronics and data acquisition system and a utilities enclosure that houses the plumbing, overflow tank, and calibration laser. The detector will be located {approx} 550 m from the Booster neutrino

  9. CMS Physics Technical Design Report, Volume II: Physics Performance

    International Nuclear Information System (INIS)

    CMS is a general purpose experiment, designed to study the physics of pp collisions at 14 TeV at the Large Hadron Collider (LHC). It currently involves more than 2000 physicists from more than 150 institutes and 37 countries. The LHC will provide extraordinary opportunities for particle physics based on its unprecedented collision energy and luminosity when it begins operation in 2007. The principal aim of this report is to present the strategy of CMS to explore the rich physics programme offered by the LHC. This volume demonstrates the physics capability of the CMS experiment. The prime goals of CMS are to explore physics at the TeV scale and to study the mechanism of electroweak symmetry breaking-through the discovery of the Higgs particle or otherwise. To carry out this task, CMS must be prepared to search for new particles, such as the Higgs boson or supersymmetric partners of the Standard Model particles, from the start-up of the LHC since new physics at the TeV scale may manifest itself with modest data samples of the order of a few fb -1 or less. The analysis tools that have been developed are applied to study in great detail and with all the methodology of performing an analysis on CMS data specific benchmark processes upon which to gauge the performance of CMS. These processes cover several Higgs boson decay channels, the production and decay of new particles such as Z' and supersymmetric particles, B s production and processes in heavy ion collisions. The simulation of these benchmark processes includes subtle effects such as possible detector miscalibration and misalignment. Besides these benchmark processes, the physics reach of CMS is studied for a large number of signatures arising in the Standard Model and also in theories beyond the Standard Model for integrated luminosities ranging from 1 fb -1 to 30 fb -1 . The Standard Model processes include QCD, B -physics, diffraction, detailed studies of the top quark properties, and electroweak physics

  10. Central hadron calorimeter of UA1

    International Nuclear Information System (INIS)

    An iron-scintillator sampling calorimeter is described, which measures hadronic energy in proton-antiproton interactions at the CERN 540 GeV SPS collider. Construction details are given of the instrumentation of the magnet pieces of the UA1 experiment and of the methods used to measure the calorimeter response and resolution. The system of lasers and quartz fibres, which allows long term monitoring of the calorimeter response, is also described. (author)

  11. Rugged calorimeter with a fast rise time

    International Nuclear Information System (INIS)

    An intrinsic 1-mil-thick gold foil calorimeter has been developed which rises to 95% of the energy deposited in less than 2 microseconds. This calorimeter is very rugged, and can withstand rough handling without damage. The time constant is long, in the millisecond range, because of its unique construction. Use of this calorimeter has produced 100% data recovery, and agreement with true deposition to less than 10%

  12. New development in high resolving power W-Si calorimeters

    International Nuclear Information System (INIS)

    The Relativistic Heavy Ion Collider (BNL) collides heavy nuclei and creates a strongly coupled medium at unprecedented density and temperature. Characteristic event structures may be efficiently selected with calorimeters, which can provide triggers on high-pT particles, 'jets' of particles, or large transverse energy, along with precision measurements of the structures. The importance of calorimeters in studies of ultrarelativistic heavy-ion collisions was first recognized by W.Willis. The key requirements are photon identification and measurements, and high resolving power to handle extreme occupancies common to this kind of interactions. We present a fully developed and beam tested concept of the W-Si sampling calorimeter built to this specifications. Novel features of this design are concepts of silicon micromodules, use of microconnectors for the silicon alignment purposes and passive signal summation to form readout towers. A prototype calorimeter was built in collaboration between BNL and a number of University groups from USA, Russia, Korea, Finland and Czech Republic and exposed to particle beams at CERN PS and SPS.

  13. Progress Status for the Mu2e Calorimeter System

    Energy Technology Data Exchange (ETDEWEB)

    Pezzullo, Gianantonio; et al.

    2015-02-13

    The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this paper, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

  14. Development of a portable graphite calorimeter for radiation dosimetry.

    Science.gov (United States)

    Sakama, Makoto; Kanai, Tatsuaki; Fukumura, Akifumi

    2008-01-01

    We developed and performance-tested a portable graphite calorimeter designed to measure the absolute dosimetry of various beams including heavy-ion beams, based on a flexible and convenient means of measurement. This measurement system is fully remote-controlled by the GPIB system. This system uses a digital PID (Proportional, Integral, Derivative) control method based on the LabVIEW software. It was possible to attain stable conditions in a shorter time by this system. The standard deviation of the measurements using the calorimeter was 0.79% at a dose rate of 0.8 Gy/min in 17 calorimeter runs for a (60)Co photon beam. The overall uncertainties for the absorbed dose to graphite and water of the (60)Co photon beam using the developed calorimeter were 0.89% and 1.35%, respectively. Estimations of the correction factors due to vacuum gaps, impurities in the core, the dose gradient and the radiation profile were included in the uncertainties. The absorbed doses to graphite and water irradiated by the (60)Co photon beam were compared with dosimetry measurements obtained using three ionization chambers. The absorbed doses to graphite and water estimated by the two dosimetry methods agreed within 0.1% and 0.3%, respectively. PMID:21976250

  15. The pulsed light calibration system of the ZEUS calorimeter

    International Nuclear Information System (INIS)

    The ZEUS calorimeter is a compensating calorimeter consisting of uranium and scintillator plates. Light is transported via light guides to photomultiplier tubes (PMTs). The design goal is an energy calibration good to within 1%. Stability is measured and PMT gains are set using the signal from uranium radioactivity. Another important component of the calibration is the pulsed light system, which distributes light from a central laser or from distributed LEDs to the photomultiplier tubes via optical fibers. The light pulse gives a similar PMT response as a signal generated by a particle in the calorimeter. This has allowed the monitoring of the following properties of the readout chain: . Number of photoelectrons/GeV/PMT. This enables us to differentiate between changes in the photomultiplier tubes and changes in the calorimeter (such as radiation damage). . Linearity of the PMT readout chain between 0 and 400 GeV. . Time delays from the PMTs and from the electronics are known to within 1 nsec. It is necessary to know these delays in order to precisely calculate the reconstructed charge and to eliminate background to e-p interactions from beam gas events. . Short-term monitoring of PMT gain. This has been used to measure PMT gain changes under varying magnetic fields to better than 1% and will be used to measure the PMT gain under varying HERA background conditions. (orig.)

  16. Digital Filtering Performance in the ATLAS Level-1 Calorimeter Trigger

    CERN Document Server

    Hadley, D R; The ATLAS collaboration

    2010-01-01

    The ATLAS Level-1 Calorimeter Trigger is a hardware-based system designed to identify high-pT jets, elec- tron/photon and tau candidates, and to measure total and missing ET in the ATLAS Liquid Argon and Tile calorimeters. It is a pipelined processor system, with a new set of inputs being evaluated every 25ns. The overall trigger decision has a latency budget of 2µs, including all transmission delays. The calorimeter trigger uses about 7200 reduced granularity analogue signals, which are first digitized at the 40 MHz LHC bunch-crossing frequency, before being passed to a digital Finite Impulse Re- sponse (FIR) filter. Due to latency and chip real-estate constraints, only a simple 5-element filter with limited precision can be used. Nevertheless, this filter achieves a significant reduction in noise, along with improving the bunch-crossing assignment and energy resolution for small signals. The context in which digital filters are used for the ATLAS Level-1 Calorimeter Trigger is presented, before descr...

  17. Digital Filter Performance for the ATLAS Level-1 Calorimeter Trigger

    CERN Document Server

    Hadley, D R; The ATLAS collaboration

    2010-01-01

    The ATLAS Level-1 Calorimeter Trigger is a hardware-based system designed to identify high-pT jets, electron/photon and tau candidates, and to measure total and missing ET in the ATLAS Liquid Argon and Tile calorimeters. It is a pipelined processor system, with a new set of inputs being evaluated every 25ns. The overall trigger decision has a latency budget of 2µs, including all transmission delays. The calorimeter trigger uses about 7200 reduced granularity analogue signals, which are first digitized at the 40 MHz LHC bunch-crossing frequency, before being passed to a digital Finite Impulse Response (FIR) filter. Due to latency and chip real-estate constraints, only a simple 5-element filter with limited precision can be used. Nevertheless this filter achieves a significant reduction in noise, along with improving the bunch-crossing assignment and energy resolution for small signals. The context in which digital filters are used for the ATLAS Level-1 Calorimeter Trigger will be presented, before describing ...

  18. A real-time low energy electron calorimeter

    International Nuclear Information System (INIS)

    A real-time low energy electron calorimeter with a thin film window has been designed and fabricated to facilitate a reliable method of dose assessment for electron beam energies down to 200 keV. The work was initiated by the Radiation Physics Group of Queen Mary and Westfield College in collaboration with the National Physical Laboratory (NPL), Teddington. Irradiations were performed on the low and medium electron energy electron accelerators at the Malaysian Institute for Nuclear Technology Research (MINT). Calorimeter response was initially tested using the on-line temperature measurements for a 500-keV electron beam. The system was later redesigned by incorporating a data-logger to use on the self-shielded 200-keV beam. In use, the final version of the calorimeter could start logging temperature a short time before the calorimeter passed under the beam and continue measurements throughout the irradiation. Data could be easily retrieved at the end of the exposure. (author)

  19. Engineering, Trade, and Technical Cluster. Task Analyses. Drafting and Design Technology, Precision Machining Technology, Electronics Technology.

    Science.gov (United States)

    Henrico County Public Schools, Glen Allen, VA. Virginia Vocational Curriculum and Resource Center.

    Developed in Virginia, this publication contains task analysis guides to support selected tech prep programs that prepare students for careers in the engineering, trade, and technical cluster. Three occupations are profiled: drafting and design technology, precision machining technology, and electronics technology. Each guide contains the…

  20. IAEA Technical committee meeting on methods used in design of spent fuel storage facilities

    International Nuclear Information System (INIS)

    The meeting was held in Espoo, Finland and hosted by the Technical Research Centre of Finland (VTT), and was arranged to report and discuss design methods, licensing practise, operational experience as well as economic aspects connectied with spent fuel storage. This report contains session summaries by the session chairmen and the papers presented at the meeting

  1. Network design of data monitoring subsystem based on ethernet of technical diagnostic system for EAST tokamak

    International Nuclear Information System (INIS)

    This article introduces a network design of the data monitoring subsystem based on Ethernet of the technical diagnostic system for EAST Tokamak. How to realize network safety is mostly described. It has been proved a reliable network with good real-time and safe performance by experiments last year. (authors)

  2. Conceptual designs of advanced fast reactor. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    A Technical Committee meeting (TCM) was held on Conceptual Designs of Advanced Fast Power Reactors to review the lessons learned from the construction and operation of demonstration and near-commercial size plants. This TCM focused on design and development of advanced fast reactors and identified methodologies to evaluate the economic competitiveness and reliability of advanced projects. The Member States which participated in the TCM were at different stages of LMFR development. The Russian Federation, Japan and India had prototype and/or experimental LMFRs and continue with mature R and D programmes. China, the Republic of Korea and Brazil were at the beginning of LMFR development. Therefore the aims of the TCM were to obtain technical descriptions of different design approaches for experimental, prototype, demonstration and commercial LMFRs, and to describe the engineering judgements made in developing the design approaches. Refs, figs, tabs

  3. Performance of the ATLAS Tile Calorimeter

    Directory of Open Access Journals (Sweden)

    Shimizu Shima

    2013-05-01

    Full Text Available The Tile Calorimeter is the central section of the ATLAS hadronic calorimeter at the Large Hadron Collider. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. Because of its very good signal to noise ratio it is also useful for the identification and reconstruction of muons. The calibration and performance of the calorimeter have been established through test beam measurements, cosmic ray muons and the large sample of pp collisions. Results on the calorimeter performance are presented, including the absolute energy scale, time resolution, and associated stabilities.

  4. ATLAS calorimeters energy calibration for jets

    International Nuclear Information System (INIS)

    The calibration of ATLAS barrel calorimeters (including pre shower system, electromagnetic Liquid Argon calorimeter and scintillating hadron tile calorimeter) was done by standard calibration and weighting technique approaches. The standard calibration gives the bad linearity for hadron non compensated calorimeter. The calibration with weighting technique, in comparison with standard calibration, restores linearity and improves energy resolution up to (σ/E)2 = (38.6%/√E)2 + (1.5%)2 for η 0.6. 6 refs., 4 figs., 1 tab

  5. Design of household calorimeter flowmeter with a temperature-controlled device%带有温度自控装置的户用热量表流量计的设计

    Institute of Scientific and Technical Information of China (English)

    王海燕

    2011-01-01

    设计了一种在超声波热量表中用的测量管道.由于超声波测量管体、传感器安装孔、传感器穿线管和安装座在焊接为一体时,难以保证各部件的相互尺寸、位置精度要求,所以设计提出将以上结构一次铸造成型,并在实现一体化的基础上加装双金属测温器.由于采用一次铸造成型,所以精度高,便于大批量生产;由于加了双金属片测温器,及由其控制伸缩改变热水流量的方形板,可自动调控室内温度,可广泛用于取暖管的控制.%Designed a calorimeter using the ultrasonic measurement of pipe.As the ultrasonic measuring tube ,the sensor mounting hole ,the sensor threading pipe and install the seat in welding as a whole ,it is difficult to ensure the various components of each size, position accuracy requirements ,so the design of the above structure ,a cast molding, and the integration of the based on the device to install pairs of metal temperature. As a result of a cast molding,so high precision,easy to mass production;due to increase of the bimetal temperature measurement devices,and flexible to change the water flow under the control of a square plate ,can automatically control the indoor temperature can be widely used for heating tube control.

  6. Cosmology, Clusters and Calorimeters

    Science.gov (United States)

    Figueroa-Feliciano, Enectali

    2005-01-01

    I will review the current state of Cosmology with Clusters and discuss the application of microcalorimeter arrays to this field. With the launch of Astro-E2 this summer and a slew of new missions being developed, microcalorimeters are the next big thing in x-ray astronomy. I will cover the basics and not-so-basic concepts of microcalorimeter designs and look at the future to see where this technology will go.

  7. Technical Support Document: 50% Energy Savings Design Technology Packages for Highway Lodging Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Gowri, Krishnan; Lane, Michael D.; Thornton, Brian A.; Rosenberg, Michael I.; Liu, Bing

    2009-09-28

    This Technical Support Document (TSD) describes the process, methodology and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document intended to provide recommendations for achieving 50% energy savings in highway lodging properties over the energy-efficiency levels contained in ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  8. Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Brian A.; Wang, Weimin; Lane, Michael D.; Rosenberg, Michael I.; Liu, Bing

    2009-09-01

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Medium Offices (AEDG-MO or the Guide), a design guidance document which intends to provide recommendations for achieving 50% energy savings in medium office buildings that just meet the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  9. Status of the ATLAS Liquid Argon Calorimeter and its performance after one year of LHC operation

    CERN Document Server

    "Hoffman, J A; The ATLAS collaboration

    2011-01-01

    The ATLAS experiment is designed to study the proton-proton collisions produced at the LHC with a centre-of-mass energy of 14 TeV. Liquid argon (LAr) sampling calorimeters are used in ATLAS for all electromagnetic calorimetry covering the pseudorapidity region η<3.2, as well as for hadronic calorimetry from η=1.4 to η=4.8. The calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic (EMEC), hadronic (HEC) and forward (FCAL) calorimeters. The lead-liquid argon sampling technique with an accordion geometry was chosen for the barrel electromagnetic calorimeter (EMB) and adapted to the endcap (EMEC). This geometry allows a uniform acceptance over the whole azimuthal range without any gap. The hadronic endcap calorimeter (HEC) uses a copper-liquid argon sampling technique with plate geometry and is subdivided into two wheels in depth per end-cap. Finally, the forward calorimeter (FCAL) is composed of three modules featuring cylindrical electrodes with thin...

  10. Test beam studies of prototype sensor planes of very forward calorimeters

    International Nuclear Information System (INIS)

    Special calorimeters are currently under development for the forward region of the future electron-positron collider. In the current detector concepts, two calorimeters are foreseen - the Luminosity Calorimeter (LumiCal) for precise luminosity measurement, and the Beam Calorimeter (BeamCal) for luminosity optimization. Both are designed as sensor-tungsten sandwich calorimeters. For each calorimeter prototypes of a sensor plane were prepared with silicon sensors for LumiCal and GaAs sensors for BeamCal. For each calorimeter, the first prototypes of sensor sectors have been prepared and assembled, with the sensor pad bonded to a fan-out on one side and to FE-ASICs developed by UST Cracow on the other. The fully assembled system was then tested in a 4 GeV electron beam at DESY II accelerator. The trajectory of beam particles was measured using a silicon strip detector telescope. The track reconstruction algorithm was adopted from telescope software and the impact points of electrons on the sensor were predicted. Results of the test beam data analysis on the performance of the system are reported.

  11. Time alignment of the front end electronics of the LHCb calorimeters.

    CERN Document Server

    Abellan Beteta, C; Ajaltouni, Z; Amhis, Y; Barsuk, S; Beigbeder-Beau, C; Belyaev, I; Bohner, G; Bonnefoy, R; Breton, D; Calvo Gómez, M; Camilleri, L; Callot, O; Camboni, A; Chanal, H; Charlet, D; Comerma-Montells, A; Cornat, R; Crouau, M; Dalmagne, B; Deschamps, O; Domingo Bonal, F; Drancourt, C; Duarte, O; Dzhelyadin, R; Egorychev, V; Filippov, S; Fulda Quenzer, F; Garra Ticó, J; Garrido, L; Gascon, D; Gaspar de Valenzuela, A; Gioi, L L; Golubkov, D; Golutvin, A; González Bano, C; Grabalosa Gàndara, M; Graciani Díaz, R; Graugés, E; Gushchin, E; Guz, Yu; Jean-Marie, B; Konoplyannikov, A; Kristic, R; Kvaratskheliya, T; Ky, B; Lecoq, J; Lefèvre, R; Lefrançois, J; López Asamar, E; Machefert, F; Machikhiliyan, I; Martens, A; Minard, M N; Monteil, S; Niess, V; Perret, P; Picatoste Olloqui, E; Puig Navarro, A; Reinmuth, G; Riera-Baburés, J; Robbe, P; Roselló, M; Ruiz, H; Savrina, D; Schopper, A; Schune, M H; Shatalov, P; Sobczak, K; T’Jampens, S; Tocut, V; Vàzquez Gómez, R; Viaud, B; Videau, I; Vilasís-Cardona, X; Zhokhov, A

    2012-01-01

    LHCb is the experiment at the Large Hadron Collider at CERN designed for performing studies of CP-symmetry violation and rare decays of B-hadrons. Its calorimeter system allows to trigger on photons and electrons by associating the information from a scintillating pad signing charged particle (SPD), a pre-shower tagging electromagnetic particle (PS), an electromagnetic calorimeter (ECAL) and a hadronic calorimeter (HCAL). We present the principles and procedures for its fine time-alignment through the commissioning and the first collision phases. We give a particular emphasis to the choices made in the electronic design of the calorimeters to deal with the signal shape and spill over. Also we summarise the achieved levels of synchronisation.

  12. The UA1 upgrade calorimeter trigger processor

    International Nuclear Information System (INIS)

    The increased luminosity of the improved CERN Collider and the more subtle signals of second-generation collider physics demand increasingly sophisticated triggering. We have built a new first-level trigger processor designed to use the excellent granularity of the UA1 upgrade calorimeter. This device is entirely digital and handles events in 1.5 μs, thus introducing no deadtime. Its most novel feature is fast two-dimensional electromagnetic cluster-finding with the possibility of demanding an isolated shower of limited penetration. The processor allows multiple combinations of triggers on electromagnetic showers, hadronic jets and energy sums, including a total-energy veto of multiple interactions and a full vector sum of missing transverse energy. This hard-wired processor is about five times more powerful than its predecessor, and makes extensive use of pipelining techniques. It was used extensively in the 1988 and 1989 runs of the CERN Collider. (author)

  13. Trigger circuits for the PHENIX electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Monolithic and discrete circuits have been developed to provide trigger signals for the PHENIX electromagnetic calorimeter detector. These trigger circuits are deadtimeless and create overlapping 4 by 4 energy sums, a cosmic muon trigger, and a 144 channel energy sum. The front end electronics of the PHENIX system sample the energy and timing channels at each bunch crossing (BC) but it is not known immediately if this data is of interest. The information from the trigger circuits is used to determine if the data collected is of interest and should be digitized and stored or discarded. This paper presents details of the design, issues affecting circuit performance, characterization of prototypes fabricated in 1.2 microm Orbit CMOS, and integration of the circuits into the EMCal electronics system

  14. Analysis of A Double Spiral Counter Flow Calorimeter in Impinging Flame Jet Using CFD Tool

    OpenAIRE

    Santosh Bagewadi; A.M.Mulla

    2015-01-01

    Enhancement of heat transfer rates in heat exchanger and calorimeter has been reported by many researchers. However, work regarding heat transfer characteristics analysis of double spiral counter flow calorimeter is not published and this forms the objective of this work. DSCFC is a unique design where it consists of single fluid as working fluid for heat exchange. Here heat transfer takes place between solid and fluid, and hence can be called as conjugate heat transfer problem. H...

  15. STAR electromagnetic calorimeter R ampersand D progress report, 1 October 1992--31 August 1993

    International Nuclear Information System (INIS)

    A lead-scintillator sampling electromagnetic calorimeter (EMC) is planned as an upgrade to the STAR detector for the RHIC Accelerator at Brookhaven National Laboratory (BNL). Considerable work on the conceptual design of the calorimeter, and related interfacing issues with the solenoids magnet and the time projection chamber (TPC) subsystems of STAR occurred in the period 1 October 1992 to 31 August 1993 (FY 1993). This report documents and summarizes the conclusions and progress from this work

  16. Technical considerations in the design of near surface disposal facilities for radioactive waste

    International Nuclear Information System (INIS)

    Good design is an important step towards ensuring operational as well as long term safety of low and intermediate level waste (LILW) disposal. The IAEA has produced this report with the objective of outlining the most important technical considerations in the design of near surface disposal facilities and to provide some examples of the design process in different countries. This guidance has been developed in light of experience gained from the design of existing near surface disposal facilities in a range of Member States. In particular the report provide information on design objective, design requirements, and design phases. The report focuses on: near surface disposal facilities accepting solidified LILW; disposal facilities on or just below the ground surface, where the final protective covering is of the order of a few metres thick; and disposal facilities several tens of metres below the ground surface (including rock cavern type facilities)

  17. Review of design approaches of advanced pressurized LWRs. Report of a technical committee meeting and workshop

    International Nuclear Information System (INIS)

    The Technical Committee Meeting and Workshop was devoted to review and discuss differences and commonalties in the various design approaches with the aim of increasing the understanding of the design decisions taken, and a number of general conclusions were drawn. Though many differences in design approaches were found in the presentations, a number of common features could also be identified. These included design approaches to achieve further improvements with respect to safety, design simplification, reduction in cost, incorporation of feedback from operating experience, and control room improvements regarding human factors and digitization. Design approaches to achieve further improvements in safety included consideration of severe accidents in the design process, increased thermal margins and water inventories, longer grace periods and double containments. Refs, figs and tabs

  18. Small reactors with simplified design. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    There is a potential future need for small reactors for applications such as district heating, electricity production at remote locations and desalination. Nuclear energy can provide an environmentally benign alternative to meet these needs. For successful deployment, small reactors must satisfy the requirements of users, regulators and the general public. The IAEA has been following the developments in the field of small reactors as a part of the sub-programme on advanced reactor technology. In accordance with the interests of Member States, a Technical Committee meeting (TCM) was organized in Mississauga, Ontario, Canada, 15-19 May 1995 to discuss the status of designs and design requirements related to small reactors for diverse applications. The papers presented at the TCM and a summary of the discussions are contained in this TECDOC which, it is hoped, will serve the Member States as a useful source of technical information on the development of small reactors with simplified design

  19. Heavy-water program: Technical requirements, conceptual design phase process, and reactor characteristics

    International Nuclear Information System (INIS)

    The Department of Energy (DOE), Office of New Production Reactors (NPRs), has initiated contracts with three architect-engineer/reactor vendors for the conceptual design phase (CDP) for new production reactors. This is the first major step of a procurement process that will proceed through final design, construction, testing, and operation of the facility. In preparation for the CDP for the NPRs, DOE developed a set of requirements that would serve as the basic technical reference throughout the entire life of the program-from the CDP to decommissioning. The objective was to establish requirements that, when met, will result in NPR capacity that will provide NPRs with design margins of sufficient magnitude to (1) provide the production capacity to supply goal quantities of tritium reliably and on a timely schedule; (2) provide a level of safety assurance that meets or exceeds that offered to the public by modern commercial nuclear power plants; (3) meet or exceed the applicable federal, state, and local regulations for safety and environmental requirements; (4) assure the availability of reactor, fuel, target, and processing technology for full-scale production on an urgent schedule with low schedule risk; and (5) meet the overall goal in the most cost-effective manner. The objectives of the CDP for the HWR [heavy-water reactor]-NPR are to provide comprehensively defined technical, cost, and schedule baselines for proceeding into preliminary design and to ensure that the technical and management competency of the CDP contractor team for conducting the preliminary design is demonstrated

  20. Heavy water program: Technical requirements, conceptual design phase process and reactor characteristics

    International Nuclear Information System (INIS)

    In preparation for the Conceptual Design Phase (CDP) for the New Production Reactors (NPRs), the Department developed a set of requirements that would serve as the basic technical reference throughout the entire life of the program - from the CDP to decommissioning. The objective was to establish requirements which when met, will result in new production reactor capacity that will provide NPRs with design margins of sufficient magnitude: that will meet or exceed the level of safety assurance achieved by recent commercial reactors; that will provide a high degree of production assurance; that will achieve a level of environmental performance which will assure that requirements established in the NEPA process are met; and that will provide a high degree of confidence that the reactor will be constructed to meet urgent schedule needs. The NPR Requirements Document sets forth the management, technical, and implementing requirements for the CDP Process. Specifically, the implementing requirements define those contractor products (e.g., records, plans, analyses, studies, designs) to be developed and delivered during the CDP. The objectives of the CDP for the HWR-NPR are to provide comprehensively defined technical, cost and schedule baselines for proceeding into preliminary design and to ensure that the technical and management competency of the CDP contractor team for conducting the preliminary design is demonstrated. The mission to produce special nuclear materials by neutron induced transmutation of target materials has a major impact on the design of the reactor core and the reactor operating systems. This leads to the use of aluminum technology and, as a consequence, low temperature operation

  1. Balancing human and technical reliability in the design of advanced nuclear reactors

    International Nuclear Information System (INIS)

    Highlights: ► Human factors exigencies are often overseen during the early design phases of NPP. ► Optimization of reactors safety is only based on technical reliability considerations. ► The search for more technical reliability often leads to more system complexity. ► System complexity is a major contributor to the operator's poor performance. ► Our method enables to assess plant complexity and it's impact on human performance. - Abstract: The strong influence of human factors (HF) on the safety of nuclear facilities is nowadays recognised and the designers are now enforced to consider HF requirements in the design of new facilities. Yet, this consideration of human factors requirements is still more or less restricted to the latest phases of the projects, essentially for the design of human-system interfaces (HSI's) and control rooms, although the design options influencing at most the human performance in operation are indeed fixed during the very early phases of the new reactors projects. The main reason of this late consideration of HF is that there exist few methods and models for anticipating the influence of fundamental design options on the future performance of operation teams. This paper describes a set of new tools permitting (i) determination of the impact of the fundamental process design options on the future activity of the operation teams and (ii) assessment of the influence of these operational constraints on teams performance. These tools are intended to guide the design of future 4th generation (GEN4) reactors, within the frame of a global risk-informed design approach, considering technical and human reliability exigencies in a balanced way.

  2. Designing Of Expert System For Technical Feasibility Evaluation Of Nuclear Power Plant

    International Nuclear Information System (INIS)

    The construction of every large-scale project such as electric power plant requires as much careful preparation as possible. This is due to the risks that may arise if any mistake occur in the planning and in the implementation. Therefore, a tool is needed to support the decision making in its construction. A knowledge-based decision making tool has been designed, to evaluate the technical feasibility of a nuclear power plant (NPP). The technical feasibility means that the NPP can be operated reliably, safely, and in accordance with the desired specifications. Among the significant consideration factors determining the technical performance are reliability factor, safety factor, ergo dynamic factor, and other important technical factors. Those factors are then detailed into the appropriate criteria and sub criteria, and further detailed into the related parameters for the purpose of evaluation. The method used for the evaluation was by assigning weight. The weighing was done by conduction surveys and by discussing with several respondents. The knowledge gathering for the design of the expert system was done by literature study and through discussion with experts. The expert system program has been made by using Delphi 3.0 software and a PC. Hardware with Intel Pentium microprocessor-133, 32 MB RAM, 1.2 GB hard-disk capacity. The recommendation given by the expert system was in the form of technical feasibility level of the evaluated NPP and some suggestion to increase the performance. The recommendation given by this program was not absolute. However, the program can be used as a tool in evaluating the feasibility of a nuclear power plant especially from the technical aspect point of view

  3. [Tampa Electric Company IGCC project]. Final public design report; Technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    This final Public Design Report (PDR) provides completed design information about Tampa Electric Company`s Polk Power Station Unit No. 1, which will demonstrate in a commercial 250 MW unit the operating parameters and benefits of the integration of oxygen-blown, entrained-flow coal gasification with advanced combined cycle technology. Pending development of technically and commercially viable sorbent for the Hot Gas Cleanup System, the HGCU also is demonstrated. The report is organized under the following sections: design basis description; plant descriptions; plant systems; project costs and schedule; heat and material balances; general arrangement drawings; equipment list; and miscellaneous drawings.

  4. Analysis of the Current Technical Issues on ASME Code and Standard for Nuclear Mechanical Design(2009)

    International Nuclear Information System (INIS)

    This report describes the analysis on the current revision movement related to the mechanical design issues of the U.S ASME nuclear code and standard. ASME nuclear mechanical design in this report is composed of the nuclear material, primary system, secondary system and high temperature reactor. This report includes the countermeasures based on the ASME Code meeting for current issues of each major field. KAMC(ASME Mirror Committee) of this project is willing to reflect a standpoint of the domestic nuclear industry on ASME nuclear mechanical design and play a technical bridge role for the domestic nuclear industry in ASME Codes application

  5. The NA48 liquid krypton calorimeter description and performances

    CERN Document Server

    Ocariz, J

    1999-01-01

    The NA48 experiment at CERN aims at making a precision study of direct CP violation in the neutral kaons, by measuring $Re(\\epsilon'/\\epsilon)$ with an accuracy better than 0.02%. To achieve this goal, the experiment requires a neutral detector with fast response, high efficiency in a high-rate environment space precision, and an excellent energy resolution (1%) in the $5 \\to 100$ GeV range. To achieve these performances, a quasi-homogeneous Liquid Krypton calorimeter has been chosen, designed with a projective tower geometry, high transversal segmentation, and fast digital readout. The calorimeter was operative during the '97 data taking period, its performances were thoroughly studied, and found to be in agreement with design requirements. A detector description and performances analysis are here presented.

  6. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    Science.gov (United States)

    Efthymiopoulos, Ilias

    2001-04-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs.

  7. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    CERN Document Server

    Efthymiopoulos, I

    2001-01-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs. (3 refs).

  8. CMS Hadron Forward Calorimeter Phase I Upgrade Status

    International Nuclear Information System (INIS)

    The CMS Hadronic Forward Calorimeter has undergone upgrade maintenance during the LHC Long Shutdown 1. The Hamamatsu R7525 PMTs have been replaced with Hamamatsu R7600U-200-M4 PMTs, which have thinner window glass that reduces window- hit events. The R7600 PMTs also have multi-anode readout feature to further enable discrimination of window-hits while also allowing the recovery of true signal energy. Higher quantum efficiency of the R7600 PMTs improves calorimeter resolution. The new PMTs were tested and calibrated; new PMT baseboards were designed and tested, and can be configured to readout 1, 2, or 4 anodes of the R7600. New radiation hard (100Gy) QIE front-end electronics were designed for reading out the new PMTs and include a TDC with < 800ps resolution. New back-end electronics based on the microTCA industrial standard have been tested

  9. LHCb: Physics with the LHCb calorimeter

    CERN Multimedia

    Barsuk, S

    2007-01-01

    The LHCb calorimeter comprises the scintillator pad detector (SPD), preshower (PS), electromagnetic Shashlyk type (ECAL) and hadronichadronic Tile (HCAL) calorimeters, arranged in pseudo-projective geometry. All the four detectors follow the general principle of reading the light from scintillator tiles with wave length shifting fibers, and transporting the light towards photomultipliers (25 ns R/O).

  10. Status of the ATLAS hadronic tile calorimeter

    International Nuclear Information System (INIS)

    Short status of the Tile Calorimeter project is given. Major achievements in the mechanical construction of the detector modules, their instrumentation, cylinders assembly, as well as the principles of the detector front-end electronics, are described. The ideas of Tile Calorimeter module calibration are presented

  11. Mounting LHCb hadron calorimeter scintillating tiles

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Scintillating tiles are carefully mounted in the hadronic calorimeter for the LHCb detector. These calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  12. Assembly of the CMS hadronic calorimeter

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    The hadronic calorimeter is assembled on the end-cap of the CMS detector in the assembly hall. Hadronic calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  13. The quality of the design project documentation in terms of technical expertise in Lithuania

    Directory of Open Access Journals (Sweden)

    M. Samofalov

    2010-03-01

    Full Text Available In this paper general situation in civil engineering design documentation is reviewed. Some characteristic mistakes in design are presented.Using their experience in engineering examination of real structural designs, authors discuss statistical data of the latest years. An attempt to improve engineering solutions using analysis of inaccuracies in design documentation and suggestion of new methods for its development, instead of creation of new theories and methods of structural analysis, is made. Such an approach in engineering is less popular as time and recourses for its implementation are required. Nevertheless, this method of solution for the problem of technical product quality and qualification of specialists is more correct.Finally, conclusions about quality as well as conditions for designers and recommendations for development of national design codes are made.

  14. Technical Meeting on Impact of Fukushima Event on Current and Future Fast Reactor Designs. Working Material

    International Nuclear Information System (INIS)

    The overall purpose of the Technical Meeting was to recognize and analyse the implications of the accident occurred at the Fukushima Dai-ichi Nuclear Power Station on current and future fast neutron systems design and operation. The aim was to provide a global forum for discussing the principal lessons learned from this event, and thus to review safety principles and characteristics of existing and future fast neutron concepts, especially in relation with extreme natural events which potentially may lead to severe accident scenarios. The participants also presented and discussed innovative technical solutions, design features and countermeasures for design extension conditions - including earthquakes, tsunami and other extreme natural hazards - which can enhance the safety level of existing and future fast neutron systems. Furthermore, the meeting gave the opportunity to present advanced methods for the evaluation of the robustness of plants against design extension conditions. Another important goal of this TM was to discuss how to harmonize safety approaches and goals for next generation’s fast reactors. Finally, the meeting was intended to identify areas where further research and development in nuclear safety, technology and engineering in the light of the Fukushima accident are needed. In the frame of the implementation of its Nuclear Safety Action Plan endorsed by all Member States, the IAEA will consider these areas as potential technical topics for new Coordinated Research Projects, to be launched in the near future

  15. IAEA Technical Meeting on Innovative Heat Exchanger and Steam Generator Designs for Fast Reactors. Working Material

    International Nuclear Information System (INIS)

    The IAEA, within the framework of its Nuclear Energy Department’s Technical Working Group on Fast Reactors (TWG-FR), assists Member States activities in fast reactors technology development areas by providing an umbrella for information exchange [topical Technical Meetings (TMs), Workshops and large Conferences] and collaborative R&D [Coordinated Research Projects (CRPs)]. The Technical meeting on “Innovative Heat Exchanger and Steam Generator Designs for Fast Reactors” was held from 21 – 22 December 2011 in Vienna, addressing Member States’ expressed needs of information exchange in the field of advanced fast reactor design features, with particular attention to innovative heat exchangers and steam generators. The Objective of the TM is to provide a global forum for in-depth information exchange and discussion on the most advanced concepts of heat exchangers and steam generators for fast reactors. More specifically, the objectives are: · Review of the status of advanced fast reactor development activities with special emphasis on design and performance of heat exchangers and steam generators; · Discuss requirements for innovative heat exchangers and steam generators; · Present results of studies and conceptual designs for innovative heat exchangers and steam generators; · Provide recommendations for international collaboration under the IAEA aegis. The meeting agenda of the meeting is in Annex I

  16. Design and validation of an observational instrument for technical and tactical actions in beach volleyball

    Directory of Open Access Journals (Sweden)

    José Manuel Palao

    2015-06-01

    Full Text Available Technical and tactical actions determine performance in beach volleyball. This research develops and tests an instrument to monitor and evaluate the manner of execution and efficacy of the actions in beach volleyball. The purpose of this paper was to design and validate an observational instrument to analyze technical and tactical actions in beach volleyball. The instrument collects information regarding: a information about the match (context, b information about game situations, c information about technical situations (serve, reception, set, attack, block, and court defense in relation to player execution, role, manner of execution, execution zone, and efficacy, and d information about the result of the play (win-lose and way point is obtained. Instrument design and validation was done in seven stages: a review of literature and consultation of experts; b pilot observation and data analysis; c expert review of instrument (qualitative and quantitative evaluation; d observer training test; e expert review of instrument (content validity; f measurement of the ability of the instrument to discriminate the result of the set; and g measurement of the ability of the instrument to differentiate between competition age groups. The results show that the instrument allows for obtaining objective and valid information about the players and team from offensive and defensive technical and tactical actions, as well as indirectly from physical actions. The instrument can be used, in its entirety or partially, for researching and coaching purposes.

  17. STEM integration in middle school career and technical education programs: A Delphi design study

    Science.gov (United States)

    Wu-Rorrer, Billy Ray

    The purpose of this qualitative method study with a Delphi research design sought to determine how STEM programs can be effectively integrated into middle school career and technical education programs by local, state, and national educators, administrators, directors, specialists, and curriculum writers. The significance of the study is to provide leaders in CTE with a greater awareness, insight, and strategies about how CTE programs can more effectively integrate academics into career and technical education programs through STEM-related programming. The findings will increase the limited amount of available literature providing best practice strategies for the integration of STEM curriculum into middle school CTE programs. One basic question has guided this research: How can STEM programs be effectively integrated into middle school career and technical education programs? A total of twelve strategies were identified. The strategies of real-world applications and administrative buy-in were the two predominant strategies consistently addressed throughout the review of literature and all three sub-questions in the research study. The Delphi design study consisted of pilot round and three rounds of data collection on barriers, strategies, and professional development for STEM integration in middle school career and technical education programs. Four panelists participated in the pilot round, and 16 panel members not involved in the pilot round participated in the three rounds of questioning and consensus building. In the future, more comprehensive studies can build upon this foundational investigation of middle school CTE programs.

  18. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Chomont, Arthur Rene; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  19. Commissioning of the ATLAS liquid argon calorimeters

    CERN Document Server

    Rezaie, Erfan

    ATLAS, a multi-purpose detector built at the LHC at CERN, requires an extensive commissioning campaign to be ready for proton-proton collisions. In this work, we focus on the commissioning of the liquid Argon (LAr) calorimeters, with emphasis on commissioning with cosmic rays. First we outline one phase of the commissioning work, which involves testing of the front-end electronics of the two endcap calorimeters. We then describe two cosmic ray generators as input to a Monte-Carlo simulation of cosmic rays in ATLAS, and compare their results. Finally, we explain a technique developed for this work which uses information from the Tile calorimeters to predict the timing of cosmic rays within the LAr calorimeters, because cosmic rays occur randomly in time whereas the electronics are clocked at [Special characters omitted.] . The results from this analysis tool are compared to default tools, using both simulated and real cosmic ray data in the calorimeters.

  20. The ATLAS Tile Calorimeter Calibration and Performance

    CERN Document Server

    Meyer, C; The ATLAS collaboration

    2013-01-01

    The Tile Calorimeter (TileCal) is the central section of the ATLAS hadronic calorimeter at the Large Hadron Collider. Scintillation light produced in the tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The resulting electronic signals from approximately 10000 PMTs are measured and digitized before being transferred to off-detector data-acquisition systems. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. Because of its very good signal to noise ratio it is also useful for the identification and reconstruction of muons. The calorimeter response is monitored to better than 1% using radioactive source, laser, and charge injection systems. This multi-faceted calibration system allows to monitor and equalize the calorimeter response at each stage of the signal production, from scintillation light to digitization. The performance of the calorimeter has also been established through test beam measurements, cosmic ray muons and t...

  1. 5.8 X-ray Calorimeters

    Science.gov (United States)

    Porter, F. Scott

    2008-01-01

    X-ray calorimeter instruments for astrophysics have seen rapid development since they were invented in 1984. The prime instrument on all currently planned X-ray spectroscopic observatories is based on calorimeter technology. This relatively simple detection concept that senses the energy of an incident photon by measuring the temperature rise of an absorber material at very low temperatures, can form the basis of a very high performance, non-dispersive spectrometer. State-of-the-art calorimeter instruments have resolving powers of over 3000, large simultaneous band-passes, and near unit efficiency. This coupled with the intrinsic imaging capability of a pixilated x-ray calorimeter array, allows true spectral-spatial instruments to be constructed. In this chapter I briefly review the detection scheme, the state-of-the-art in X-ray calorimeter instruments and the future outlook for this technology.

  2. A MAPS-based Digital Electromagnetic Calorimeter for the ILC

    OpenAIRE

    Ballin, J. A.; Dauncey, P. D.; Magnan, A. -M.; Noy, M.; Y. Mikami; Miller, O.; Rajović, V.; Watson, N. K.; Wilson, J. A.; Crooks, J. P.; Stanitzki, M.; Stefanov, K. D.; R. Turchetta; Tyndel, M.; Villani, E. G.

    2007-01-01

    A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical sensor is done using a detailed three-dimensional charge spread algorithm. Physics studies of the sensor are done including a digitisation algorithm taking into account the charge sharing, charge collection efficiency, noise, and dead areas. The influence of...

  3. On timing properties of LYSO-based calorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Apresyan, A. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Bornheim, A. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Duarte, J. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Pena, C. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Ronzhin, A. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Spiropulu, M. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Trevor, J. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Xie, S. [California Inst. of Technology (CalTech), Pasadena, CA (United States)

    2015-04-23

    We present test beam studies and results on the timing performance and characterization of the time resolution of Lutetium–Yttrium Orthosilicate (LYSO)-based calorimeters. We also demonstrate that a time resolution of 30 ps is achievable for a particular design. Additionally, we discuss precision timing calorimetry as a tool for the mitigation of physics object performance degradation effects due to the large number of simultaneous interactions in the high luminosity environment foreseen at the Large Hadron Collider.

  4. On timing properties of LYSO-based calorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D.; Apresyan, A.; Bornheim, A.; Duarte, J.; Pena, C. [California Institute of Technology, Pasadena, CA (United States); Ronzhin, A. [Fermi National Accelerator Laboratory, Batavia, IL (United States); Spiropulu, M., E-mail: smaria@caltech.edu [California Institute of Technology, Pasadena, CA (United States); Trevor, J.; Xie, S. [California Institute of Technology, Pasadena, CA (United States)

    2015-09-11

    We present test beam studies and results on the timing performance and characterization of the time resolution of Lutetium–Yttrium Orthosilicate (LYSO)-based calorimeters. We demonstrate that a time resolution of 30 ps is achievable for a particular design. Furthermore, we discuss precision timing calorimetry as a tool for the mitigation of physics object performance degradation effects due to the large number of simultaneous interactions in the high luminosity environment foreseen at the Large Hadron Collider.

  5. Stabilized dye laser for crystal electromagnetic calorimeter monitoring

    CERN Document Server

    Singovsky, A V; Korzhik, M V; Lopatik, A; Peigneux, J P; Moinester, M A; Steiner, V

    2002-01-01

    A slow laser output drift stabilization system was described. The system stabilized the light output of a commercial dye laser to the level of 0.3%. The results showed that the use of a stabilized laser light source for monitoring of electromagnetic calorimeter crystals would simplify the monitoring system design. It would also improve the overall monitoring system performance by removing the light output correction term. (Edited abstract) 15 Refs. --- 22 --- AN

  6. Design, construction, and calibration of an isothermal titration calorimeter and its application in the study of the adsorption of phenolic compounds.

    Science.gov (United States)

    Moreno-Piraján, Juan Carlos; Giraldo, Liliana

    2012-01-01

    An isothermal calorimetric titration was designed and built, and some of the results obtained are presented here. For this purpose, a Calvet heat-conducting microcalorimeter was developed and connected to a titration unit built for this experiment to record titration thermograms. The microcalorimeter was electrically calibrated to establish its sensitivity and reproducibility, obtaining K = 13.56 ± 0.21 W V(-1). Additionally, the equipment was tested using the heat of neutralisation for the tris-hydroxymethyl-aminomethane-HCl (THAM-HCl) system, obtaining ΔH = -30.92 ± 0.03 kJ mol(-1). The unit was assembled to obtain titration heats and the corresponding thermodynamic variables (ΔH, ΔG, ΔS, and K(e)) with a system of phenolic derivatives-activated carbon (synthesised from potato peel). PMID:22299996

  7. Design, construction, and calibration of an isothermal titration calorimeter and its application in the study of the adsorption of phenolic compounds

    Science.gov (United States)

    Moreno-Piraján, Juan Carlos; Giraldo, Liliana

    2012-01-01

    An isothermal calorimetric titration was designed and built, and some of the results obtained are presented here. For this purpose, a Calvet heat-conducting microcalorimeter was developed and connected to a titration unit built for this experiment to record titration thermograms. The microcalorimeter was electrically calibrated to establish its sensitivity and reproducibility, obtaining K = 13.56 ± 0.21 W V-1. Additionally, the equipment was tested using the heat of neutralisation for the tris-hydroxymethyl-aminomethane-HCl (THAM-HCl) system, obtaining ΔH = -30.92 ± 0.03 kJ mol-1. The unit was assembled to obtain titration heats and the corresponding thermodynamic variables (ΔH, ΔG, ΔS, and Ke) with a system of phenolic derivatives-activated carbon (synthesised from potato peel).

  8. Integral design concepts of advanced water cooled reactors. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    Under the sub-programme on non-electrical applications of advanced reactors, the International Atomic Energy Agency has been providing a worldwide forum for exchange of information on integral reactor concepts. Two Technical Committee meetings were held in 1994 and 1995 on the subject where state-of-the-art developments were presented. Efforts are continuing for the development of advanced nuclear reactors of both evolutionary and innovative design, for electricity, co-generation and heat applications. While single purpose reactors for electricity generation may require small and medium sizes under certain conditions, reactors for heat applications and co-generation would be necessary in the small and medium range and need to be located closer to the load centres. The integral design approach to the development of advanced light water reactors has received special attention over the past few years. Several designs are in the detailed design stage, some are under construction, one prototype is in operation. A need has been felt for guidance on a number of issues, ranging from design objectives to the assessment methodology needed to show how integral designs can meet these objectives, and also to identify their advantages and problem areas. The technical document addresses the current status of the design, safety and operational issues of integral reactors and recommends areas for future development

  9. The ATLAS Tile Calorimeter performance at LHC in pp collisions at 7 TeV

    Directory of Open Access Journals (Sweden)

    Bertolucci Federico

    2012-06-01

    Full Text Available The Tile Calorimeter (TileCal, the central section of the hadronic calorimeter of the ATLAS experiment, is a key detector component to detect hadrons, jets and taus and to measure the missing transverse energy. Due to the very good muon signal to noise ratio it assists the muon spectrometer in the identification and reconstruction of muons. The performance of the calorimeter has been measured and monitored using calibration data, random triggered data, cosmic muons, splash events and more importantly LHC collision events. The results presented assess the absolute energy scale calibration precision, the energy and timing uniformity and the synchronization precision. The results demonstrate a very good understanding of the performance of the Tile Calorimeter that is well within the design expectations.

  10. Prototype tests for a highly granular scintillator-based hadron calorimeter

    International Nuclear Information System (INIS)

    Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future linear collider detector are studied. After having demonstrated the capabilities of the measurement methods in physics prototypes, the focus now lies on improving their implementation intechnological prototypes, that are scalable to the full linear collider detector. The Analog Hadron Calorimeter (AHCAL) concept is a sampling calorimeter of tungsten or steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers as active material. In the AHCAL technological prototype, the front-end chips are integrated into the active layers of the calorimeter and are designed for minimal power consumption. The versatile electronics allows the prototype to be equipped with different types of scintillator tiles and SiPMs. The current status of the AHCAL engineering prototype is shown and recent beam test measurements as well as plans for future hadron beam tests with a larger prototype will be discussed

  11. Performance of the ATLAS Calorimeters and Commissioning for LHC Run-2

    CERN Document Server

    Rossetti, Valerio; The ATLAS collaboration

    2015-01-01

    The ATLAS general-purpose experiment at the Large Hadron Collider (LHC) is equipped with electromagnetic and hadronic liquid-argon (LAr) calorimeters and a hadronic scintillator-steel sampling calorimeter (TileCal) for measuring energy and direction of final state particles in the pseudorapidity range $|\\eta| < 4.9$. The calibration and performance of the calorimetry system was established during beam tests, cosmic ray muon measurements and in particular the first three years of pp collision data-taking. During this period, referred to as Run-1, approximately 27~fb$^{-1}$ of data have been collected at the center-of-mass energies of 7 and 8~TeV. Results on the calorimeter operation, monitoring and data quality, as well as their performance will be presented, including the calibration and stability of the electromagnetic scale, response uniformity and time resolution. These results demonstrate that the LAr and Tile calorimeters perform excellently within their design requirements. The calorimetry system thu...

  12. Construction and Performance of an Iron-Scintillator Hadron Calorimeter with Longitudinal Tile Configuration

    CERN Multimedia

    2002-01-01

    % RD34 \\\\ \\\\ In a scintillator tile calorimeter with wavelength shifting fiber readout significant simplifications of the construction and the assembly are possible if the tiles are oriented $^{\\prime\\prime}$longitudinally$^{\\prime\\prime}$, i.e.~in a r-$\\phi$ planes for a barrel configuration. For a hybrid calorimeter consisting of a scintillator tile hadron compartment and a sufficiently containing liquid argon electromagnetic (EM) compartment, as proposed for the ATLAS detector, good jet resolution is predicted by simulations, which is not affected by this particular orientation of the tiles. \\\\ \\\\The aim of the proposed development program is to construct a calorimeter test module with longitudinal tiles and to check the simulation results by test beam measurements. In addition several component tests and further simulations and engineering studies are needed to optimize the design of a large calorimeter structure to be used in collider experiments. The construction of a test module will also provide valua...

  13. Functional design criteria for an exploratory shaft facility in salt: Technical report

    International Nuclear Information System (INIS)

    The purpose of the Functional Criteria for Design is to provide technical direction for the development of detailed design criteria for the exploratory shaft facility. This will assure that the exploratory shaft facility will be designed in accordance with the current Mission Plan as well as the Nuclear Waste Policy Act and 10 CFR Part 60, which will facilitate the licensing process. The functional criteria for design are not intended to limit or constrain the designer's flexibility. The following philosophies will be incorporated in the designs: (1) The exploratory shaft will be designed to fulfill its intended purpose which is to characterize the salt site by subsurface testing; (2) the design will minimize any adverse impact which the facility may cause to the environment and any damage to the site if it should be found suitable for a repository; (3) the health and safety of the public and of the workers will be an essential factor in the design; (4) sound engineering principles and practices will be consistently employed in the design process; (5) the exploratory shaft and related surface and subsurface facilities will be designed to be economical and reliable in construction, operation, and maintenance; and (6) the exploratory shaft facility will be designed in accordance with applicable federal, state, and local regulations, as well as all applicable national consensus codes and standards

  14. Performance of operating and advanced light water reactor designs. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    Nuclear power can provide security of energy supply, stable energy costs, and can contribute to greenhouse gas reduction. To fully realize these benefits, a continued and strong focus must be maintained on means for assuring the economic competitiveness of nuclear power relative to alternatives. Over the past several years, considerable improvements have been achieved in nuclear plant performance. Worldwide, the average energy availability factor has increased from 66 per cent in 1980 to 81 per cent in 1999, with some utilities achieving significantly higher values. This is being achieved through integrated programmes including personnel training and quality assurance, improvements in plant system and component design and plant operation, by various means to reduce outage duration for maintenance and refuelling and other scheduled shutdowns, and by reducing the number of forced outages. Application of technical means for achieving high performance of nuclear power plants is an important element for assuring their economic competitiveness. For the current plants, proper management includes development and application of better technologies for inspection, maintenance and repair. For future plants, the opportunity exists during the design phase to incorporate design features and technologies for achieving high performance. This IAEA Technical Committee meeting (TCM) provided a forum for information exchange on design features and technologies incorporated into LWR plants commissioned within the last 15-20 years, and into evolutionary LWR designs still under development, for achieving performance improvements with due regard to stringent safety requirements and objectives. It also addressed on-going technology development expected to achieve further improvements and/or significant cost reductions. The TCM was attended by 32 participants from 14 Member States: Argentina, Bulgaria, Czech Republic, Finland, France, Germany, Hungary, Japan, Republic of Korea, Mexico

  15. Informational Reinforcement of Students’ Course Design Aimed at Promoting Engineers Training Quality in Technical Education

    Directory of Open Access Journals (Sweden)

    B. N. Guzanov

    2012-01-01

    Full Text Available Using the modern information technologies in educational process is regarded as one of the main directions in training the qualified specialists with systematic engineering thinking. The optimum combination of various educational technologies and computerized resources can improve teaching quality and promote students’ professional level. Taking as an example one of the basic technical disciplines of the engineering training curriculum at a technical higher school, the authors describe the computerized technology facilitating the course design. The technology in question - the «Reduktor» courseware - adapts the complex product of Autodesk –AutoCAD for educational purposes. The above program is the enhanced interface of AutoCAD, linked to the Microsoft Excel spreadsheet and the reference data library used for designing the reduction gear. The experimental research, based on the qualimetric approach and continuous diagnostic and prognostic monitoring of the key indices of knowledge acquisition, proves the effectiveness of informational reinforcement of students self-dependent work. 

  16. Technical specification for design, fabrication, use and maintenance of tie-down system

    International Nuclear Information System (INIS)

    IAEA Safety Series ndeg6 states that to ensure compliance with the Regulation the programs of quality assurance must be put in practice either for design, manufacture, testing, documentation, use and maintenance and inspection of all packages or for transport and intransit storage operations. Therefore in view of a standardization coming from Q.A. criteria, the Italian Competent Authority for transport of radioactive material (ENEA-DISP) is preparing a technical guide for the design, construction, use and maintenance of tie-down system for road transport of packages containing radioactive materials. The paper shows some phases of the program started by ENEA-DISP for the redaction of the technical guide. (J.P.N.)

  17. New Physics requirements and technological challenges to be confronted by calorimeters in particle physics

    International Nuclear Information System (INIS)

    The seminar presents an introduction to calorimetry in particle physics. Initially the purpose of electromagnetic and hadronic calorimeters in particle physics is shown. Then the paper focusses on electromagnetic calorimeters and it describes the microscopic phenomena that drive the formation of electromagnetic showers. Homogeneous and sampling calorimeters are presented and the energy resolution of both is analyzed. A few examples of past and present electromagnetic calorimeters at particle colliders are presented, with particular attention to the ones employed in the Atlas and CMS experiments at the LHC, their design constraints, challenges and adopted choices. Both these calorimeters were designed to operate for a minimum of ten years at the LHC, with an instantaneous luminosity of 1· 1034/cm2/s and for an integrated luminosity of 500/fb. From 2023 a new program will start: the high luminosity LHC (HL-LHC), which is expected to provide an instantaneous luminosity of around 5· 1034/cm2/s and integrate a total luminosity of around 3000/fb in ten years of data taking. The evolution of the CMS and Atlas calorimeters is assessed and needed upgrades are presented

  18. An architecture and methodology for the design and development of Technical Information Systems

    OpenAIRE

    Capobianchi, R.; Mautref, M.; Keulen, van, Maurice; Balsters, H.

    1996-01-01

    In order to meet demands in the context of Technical Information Systems (TIS) pertaining to reliability, extensibility, maintainability, etc., we have developed an architectural framework with accompanying methodological guidelines for designing such systems. With the framework, we aim at complex multiapplication information systems using a repository to share data among applications. The framework proposes to keep a strict separation between Man-Machine-Interface and Model data, and provide...

  19. Advanced earth observation spacecraft computer-aided design software: Technical, user and programmer guide

    Science.gov (United States)

    Farrell, C. E.; Krauze, L. D.

    1983-01-01

    The IDEAS computer of NASA is a tool for interactive preliminary design and analysis of LSS (Large Space System). Nine analysis modules were either modified or created. These modules include the capabilities of automatic model generation, model mass properties calculation, model area calculation, nonkinematic deployment modeling, rigid-body controls analysis, RF performance prediction, subsystem properties definition, and EOS science sensor selection. For each module, a section is provided that contains technical information, user instructions, and programmer documentation.

  20. Method of single technical information security system designing with probable reliability and given parameters of breaking

    OpenAIRE

    Журиленко, Борис Євгенович; Национальный авиационный университет

    2014-01-01

    As a result of the work was proposed a method of single technical information security (TIS) system designing with probable reliability and given parameters of breaking. The general dependence between effort and time of breaking by projected frequency of breaking was defined. It is shown that the parameter that determines the probable reliability of TIS may not only be a constant with the time dimension, but depends on both the attempt of breaking and time of breaking. Through the attempt of ...

  1. Construction of the Zeus forward/rear calorimeter modules at NIKHEF

    International Nuclear Information System (INIS)

    ZEUS is one of the two experiments in preparation for studying electron-proton interactions at the HERA e-p collider at DESY in Hamburg. The design value for the energy of the electron beam is 30 GeV and for the proton beam 820 GeV. The asymmetry in the beam particle masses and their energies causes in general a strongly asymmetric energy distribution for the reaction products, in particular most of the energy flow will be in the proton direction. The layout of the ZEUS detector accomodates for this asymmetry. In the proton direction for instance, several wirechambers assure together with the central tracking detector good track reconstruction, in an area where high density of tracks is expected. The tracking detector is placed inside a magnetic field of 1.8 Tesla, provided by a superconducting coil. The interaction point is completely surrounded by a high resolution calorimeter, which in turn is surrounded by a backing calorimeter; this backing calorimeter has to detect late showering particles, has to serve as a muon filter and is also the return yoke for the magnetic field. The ZEUS collaboration has chosen for a type of hadron calorimeter with the best possible energy resolution known to date, a depleted uranium-scintillator sampling calorimeter. The calorimeter has an equal response to electrons and hadrons of the same energy (e/h=1). The sampling thickness is one radiation length. The calorimeter is subdivided in three components, the forward- (in proton direction), the rear- (in electron direction) and the barrel calorimeter, FCAL, RCAL and BCAL. In this report the design and assembly procedure of the FCAL/RCAL is described in detail. Furthermore the transport problems are discussed and the first calibration results obtained with beam particles are shown. (author). 5 refs.; 29 figs.; 1 tab

  2. WE-G-17A-06: A Water Calorimeter for Use in MRI Linacs

    International Nuclear Information System (INIS)

    Purpose: At VSL, Dutch Metrology Institute, a new water calorimeter was developed with the purpose to replace the existing primary standard for absorbed dose to water in the Netherlands. The new water calorimeter is designed to be operable in medium- to high energy photon beams, electrons, protons as well as MRI integrated linear accelerators. VSL has operated a water calorimeter since 2001. This calorimeter formed the basis for the NCS-18 dosimetry protocol, which is commonly applied by medical physicists in the Netherlands and Belgium. Methods: The unit Gray is the unit of interest for measurement of the absorbed dose to water. Water calorimetry involves the measurement of a small temperature rise (0.24 mK/Gy) with an uncertainty of less than 1 μK/Gy at a temperature of 4 °C. Using extensive multi-physics simulations the new calorimeter's thermal performance was simulated before it was constructed at the end of 2013. With the advent of radiotherapy treatment units incorporating MR imaging the performance of the thermistor temperature sensors were characterized in a 1.5 T magnetic field. Results: A change of thermistor resistance was observed of less than 0.004% as a Result of the magneto-resistance effect in a 1.5 T magnetic field. Although a magneto-resistance effect was detectable, the effect on the temperature response in the water calorimeter was found to be negligible. Conclusion: With the realization of the new calorimeter operable in MRI linacs and designed for use in a variety of beam modalities, VSL is ready for accurate dosimetry in new advanced radiotherapy modalities. Due to the small form factor the calorimeter can be used on location in the actual therapy beam inside a 68 cm linac bore. This work was supported by EMRP grant HLT06. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union

  3. IsoDAR@KamLAND: A Conceptual Design Report for the Technical Facility

    CERN Document Server

    Abs, M; Alonso, J R; Axani, S; Barletta, W A; Barlow, R; Bartoszek, L; Bungau, A; Calabretta, L; Calanna, A; Campo, D; Castro, G; Celona, L; Collin, G H; Conrad, J M; Gammino, S; Johnson, R; Karagiorgi, G; Kayser, S; Kleeven, W; Kolano, A; Labrecque, F; Loinaz, W A; Minervini, J; Moulai, M H; Okuno, H; Owen, H; Papavassiliou, V; Shaevitz, M H; Shimizu, I; Shokair, T M; Sorensen, K F; Spitz, J; Toups, M; Vagins, M; Van Bibber, K; Wascko, M O; Winklehner, D; Winslow, L A; Yang, J J

    2015-01-01

    This conceptual design report describes the technical facility for the IsoDAR electron-antineutrino source at KamLAND. The IsoDAR source will allow an impressive program of neutrino oscillation and electroweak physics to be performed at KamLAND. This report provides information on the physics case, the conceptual design for the subsystems, alternative designs considered, specifics of installation at KamLAND, and identified needs for future development. We discuss the risks we have identified and our approach to mitigating those risks with this design. A substantial portion of the conceptual design is based on three years of experimental efforts and on industry experience. This report also includes information on the conventional facilities.

  4. Compassionate containment? Balancing technical safety and therapy in the design of psychiatric wards.

    Science.gov (United States)

    Curtis, Sarah; Gesler, Wilbert; Wood, Victoria; Spencer, Ian; Mason, James; Close, Helen; Reilly, Joseph

    2013-11-01

    This paper contributes to the international literature examining design of inpatient settings for mental health care. Theoretically, it elaborates the connections between conceptual frameworks from different strands of literature relating to therapeutic landscapes, social control and the social construction of risk. It does so through a discussion of the substantive example of research to evaluate the design of a purpose built inpatient psychiatric health care facility, opened in 2010 as part of the National Health Service (NHS) in England. Findings are reported from interviews or discussion groups with staff, patients and their family and friends. This paper demonstrates a strong, and often critical awareness among members of staff and other participants about how responsibilities for risk governance of 'persons' are exercised through 'technical safety' measures and the implications for therapeutic settings. Our participants often emphasised how responsibility for technical safety was being invested in the physical infrastructure of certain 'places' within the hospital where risks are seen to be 'located'. This illuminates how the spatial dimensions of social constructions of risk are incorporated into understandings about therapeutic landscapes. There were also more subtle implications, partly relating to 'Panopticist' theories about how the institution uses technical safety to supervise its own mechanisms, through the observation of staff behaviour as well as patients and visitors. Furthermore, staff seemed to feel that in relying on technical safety measures they were, to a degree, divesting themselves of human responsibility for risks they are required to manage. However, their critical assessment showed their concerns about how this might conflict with a more therapeutic approach and they contemplated ways that they might be able to engage more effectively with patients without the imposition of technical safety measures. These findings advance our thinking

  5. Study of the performance of a compact sandwich calorimeter for the instrumentation of the very forward region of a future linear collider detector

    OpenAIRE

    Ghenescu, V.; Benhammou, Y.

    2016-01-01

    The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These calorimeters are designed as sensor-tungsten calorimeters with very thin sensor planes to keep the Moliere radius small and dedicated FE electronics to match the timing and dynamic range requirements. A partially instrumented prototype was investigated in the C...

  6. Development of the JNC geological disposal technical information integration system subjected for repository design and safety assessment

    International Nuclear Information System (INIS)

    On this work, system manufacture about disposal technology and safety assessment field was performed towards construction of the JNC Geological Disposal Technical Information Integration System which systematized three fields of technical information acquired in investigation (site characteristic investigation) of geology environmental conditions, disposal technology (design of deep repository), and performance/safety assessment. The technical information database managed focusing on the technical information concerning individual research of an examination, analysis, etc. and the parameter set database managed focusing on the set up data set used in case of comprehensive evaluation are examined. In order to support and promote share and use of the technical information registered and managed by the database, utility functions, such as a technical information registration function, technical information search/browse function, analysis support function, and visualization function, are considered, and the system realized in these functions is built. The built system is installed in the server of JNC, and the functional check examination is carried out. (author)

  7. Staff technical position on regulatory considerations in the design and construction of the exploratory shaft facility

    International Nuclear Information System (INIS)

    The staff of the US Nuclear Regulatory Commission has prepared this staff technical position for the purpose of compiling and further clarifying previous staff positions on regulatory considerations in the design and construction of the exploratory shaft facility (ESF). (The US Department of Energy (DOE) now refers to the ESF as the ''exploratory studies facility.'' DOE's change in terminology does not affect the positions taken in this guidance.) This document lists the key regulations in 10 CFR Part 60 that should be considered in the design and construction of the ESF and presents the staff position statements and corresponding discussions. 13 refs., 1 fig

  8. Creep-fatigue damage rules for advanced fast reactor design. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    The IAEA, following the recommendations of the International Working Group on Fast Reactors, convened a Technical Committee Meeting on Creep-Fatigue Damage Rules to be used in Fast Reactor Design. The objective of the meeting was to review developments in design rules for creep-fatigue conditions and to identify any areas in which further work would be desirable. The meeting was hosted by AEA Technology, Risley, and held in Manchester, United Kingdom, 11-13 June 1996. It was attended by experts from the European Commission, France, India, Japan, the Republic of Korea, the Russian Federation and the United Kingdom. Refs, figs, tabs

  9. Readiness of the ATLAS Tile Calorimeter for LHC collisions

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdelalim, Ahmed Ali; Abdesselam, Abdelouahab; Abdinov, Ovsat; Abi, Babak; Abolins, Maris; Abramowicz, Halina; Abreu, Henso; Acharya, Bobby Samir; Adams, David; Addy, Tetteh; Adelman, Jahred; Adorisio, Cristina; Adragna, Paolo; Adye, Tim; Aefsky, Scott; Aguilar-Saavedra, Juan Antonio; Aharrouche, Mohamed; Ahlen, Steven; Ahles, Florian; Ahmad, Ashfaq; Ahsan, Mahsana; Aielli, Giulio; Akdogan, Taylan; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov , Andrei; Aktas, Adil; Alam, Mohammad; Alam, Muhammad Aftab; Albrand, Solveig; Aleksa, Martin; Aleksandrov, Igor; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Aliev, Malik; Alimonti, Gianluca; Alison, John; Aliyev, Magsud; Allport, Phillip; Allwood-Spiers, Sarah; Almond, John; Aloisio, Alberto; Alon, Raz; Alonso, Alejandro; Alviggi, Mariagrazia; Amako, Katsuya; Amelung, Christoph; Amorim, Antonio; Amorós, Gabriel; Amram, Nir; Anastopoulos, Christos; Andeen, Timothy; Anders, Christoph Falk; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Anduaga, Xabier; Angerami, Aaron; Anghinolfi, Francis; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonelli, Stefano; Antos, Jaroslav; Antunovic, Bijana; Anulli, Fabio; Aoun, Sahar; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Arce, Ayana; Archambault, John-Paul; Arfaoui, Samir; Arguin, Jean-Francois; Argyropoulos, Theodoros; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnault, Christian; Artamonov, Andrei; Arutinov, David; Asai, Makoto; Asai, Shoji; Silva, José; Asfandiyarov, Ruslan; Ask, Stefan; Åsman, Barbro; Asner, David; Asquith, Lily; Assamagan, Ketevi; Astvatsatourov, Anatoli; Atoian, Grigor; Auerbach, Benjamin; Augsten, Kamil; Aurousseau, Mathieu; Austin, Nicholas; Avolio, Giuseppe; Avramidou, Rachel Maria; Ay, Cano; Azuelos, Georges; Azuma, Yuya; Baak, Max; Bach, Andre; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Badescu, Elisabeta; Bagnaia, Paolo; Bai, Yu; Bain, Travis; Baines, John; Baker, Mark; Baker, Oliver Keith; Baker, Sarah; Baltasar Dos Santos Pedrosa, Fernando; Banas, Elzbieta; Banerjee, Piyali; Banerjee, Swagato; Banfi, Danilo; Bangert, Andrea Michelle; Bansal, Vikas; Baranov, Sergei; Barashkou, Andrei; Barber, Tom; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Bardin, Dmitri; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Baroncelli, Antonio; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Barrillon, Pierre; Bartoldus, Rainer; Bartsch, Detlef; Bates, Richard; Batkova, Lucia; Batley, Richard; Battaglia, Andreas; Battistin, Michele; Bauer, Florian; Bawa, Harinder Singh; Bazalova, Magdalena; Beare, Brian; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Graham; Beck, Hans Peter; Beckingham, Matthew; Becks, Karl-Heinz; Beddall, Ayda; Beddall, Andrew; Bednyakov, Vadim; Bee, Christopher; Begel, Michael; Behar Harpaz, Silvia; Behera, Prafulla; Beimforde, Michael; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellina, Francesco; Bellomo, Massimiliano; Belloni, Alberto; Belotskiy, Konstantin; Beltramello, Olga; Ben Ami, Sagi; Benary, Odette; Benchekroun, Driss; Bendel, Markus; Benedict, Brian Hugues; Benekos, Nektarios; Benhammou, Yan; Benjamin, Douglas; Benoit, Mathieu; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Beretta, Matteo; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Berglund, Elina; Beringer, Jürg; Bernat, Pauline; Bernhard, Ralf; Bernius, Catrin; Berry, Tracey; Bertin, Antonio; Besana, Maria Ilaria; Besson, Nathalie; Bethke, Siegfried; Bianchi, Riccardo-Maria; Bianco, Michele; Biebel, Otmar; Biesiada, Jed; Biglietti, Michela; Bilokon, Halina; Bindi, Marcello; Bingul, Ahmet; Bini, Cesare; Biscarat, Catherine; Bitenc, Urban; Black, Kevin; Blair, Robert; Blanchard, Jean-Baptiste; Blanchot, Georges; Blocker, Craig; Blondel, Alain; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bocci, Andrea; Boehler, Michael; Boek, Jennifer; Boelaert, Nele; Böser, Sebastian; Bogaerts, Joannes Andreas; Bogouch, Andrei; Bohm, Christian; Bohm, Jan; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Bondarenko, Valery; Bondioli, Mario; Boonekamp, Maarten; Bordoni, Stefania; Borer, Claudia; Borisov, Anatoly; Borissov, Guennadi; Borjanovic, Iris; Borroni, Sara; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Bouchami, Jihene; Boudreau, Joseph; Bouhova-Thacker, Evelina Vassileva; Boulahouache, Chaouki; Bourdarios, Claire; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozovic-Jelisavcic, Ivanka; Bracinik, Juraj; Braem, André; Branchini, Paolo; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brelier, Bertrand; Bremer, Johan; Brenner, Richard; Bressler, Shikma; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Brodet, Eyal; Bromberg, Carl; Brooijmans, Gustaaf; Brooks, William; Brown, Gareth; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Bucci, Francesca; Buchanan, James; Buchholz, Peter; Buckley, Andrew; Budagov, Ioulian; Budick, Burton; Büscher, Volker; Bugge, Lars; Bulekov, Oleg; Bunse, Moritz; Buran, Torleiv; Burckhart, Helfried; Burdin, Sergey; Burgess, Thomas; Burke, Stephen; Busato, Emmanuel; Bussey, Peter; Buszello, Claus-Peter; Butin, Françcois; Butler, Bart; Butler, John; Buttar, Craig; Butterworth, Jonathan; Byatt, Tom; Caballero, Jose; Cabrera Urbán, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Calvet, David; Camarri, Paolo; Cameron, David; Campana, Simone; Campanelli, Mario; Canale, Vincenzo; Canelli, Florencia; Canepa, Anadi; Cantero, Josu; Capasso, Luciano; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capua, Marcella; Caputo, Regina; Caramarcu, Costin; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Bryan; Caron, Sascha; Carrillo Montoya, German D.; Carron Montero, Sebastian; Carter, Antony; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Cascella, Michele; Castaneda Hernandez, Alfredo Martin; Castaneda-Miranda, Elizabeth; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Cataldi, Gabriella; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cavalleri, Pietro; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Cerqueira, Augusto Santiago; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cetin, Serkant Ali; Chafaq, Aziz; Chakraborty, Dhiman; Chan, Kevin; Chapman, John Derek; Chapman, John Wehrley; Chareyre, Eve; Charlton, Dave; Chavda, Vikash; Cheatham, Susan; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chen, Hucheng; Chen, Shenjian; Chen, Xin; Cheplakov, Alexander; Chepurnov, Vladimir; Cherkaoui El Moursli, Rajaa; Tcherniatine, Valeri; Chesneanu, Daniela; Cheu, Elliott; Cheung, Sing-Leung; Chevalier, Laurent; Chevallier, Florent; Chiefari, Giovanni; Chikovani, Leila; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chizhov, Mihail; Choudalakis, Georgios; Chouridou, Sofia; Christidi, Illectra-Athanasia; Christov, Asen; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Ciapetti, Guido; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciobotaru, Matei Dan; Ciocca, Claudia; Ciocio, Alessandra; Cirilli, Manuela; Clark, Allan G.; Clark, Philip James; Cleland, Bill; Clemens, Jean-Claude; Clement, Benoit; Clement, Christophe; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H.; Coggeshall, James; Cogneras, Eric; Colijn, Auke-Pieter; Collard, Caroline; Collins, Neil; Collins-Tooth, Christopher; Collot, Johann; Colon, German; Conde Muiño, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Consonni, Michele; Constantinescu, Serban; Conta, Claudio; Conventi, Francesco; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cooper-Smith, Neil; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Corso-Radu, Alina; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Costin, Tudor; Côté, David; Coura Torres, Rodrigo; Courneyea, Lorraine; Cowan, Glen; Cowden, Christopher; Cox, Brian; Cranmer, Kyle; Cranshaw, Jack; Cristinziani, Markus; Crosetti, Giovanni; Crupi, Roberto; Crépé-Renaudin, Sabine; Cuenca Almenar, Cristóbal; Cuhadar Donszelmann, Tulay; Curatolo, Maria; Curtis, Chris; Cwetanski, Peter; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; D'Orazio, Alessia; Da Via, Cinzia; Dabrowski, Wladyslaw; Dai, Tiesheng; Dallapiccola, Carlo; Dallison, Steve; Daly, Colin; Dam, Mogens; Danielsson, Hans Olof; Dannheim, Dominik; Dao, Valerio; Darbo, Giovanni; Darlea, Georgiana Lavinia; Davey, Will; Davidek, Tomas; Davidson, Nadia; Davidson, Ruth; Davies, Merlin; Davison, Adam; Dawson, Ian; Daya, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Castro Faria Salgado, Pedro; De Cecco, Sandro; de Graat, Julien; De Groot, Nicolo; de Jong, Paul; De Mora, Lee; De Oliveira Branco, Miguel; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dean, Simon; Dedovich, Dmitri; Degenhardt, James; Dehchar, Mohamed; Del Papa, Carlo; Del Peso, Jose; Del Prete, Tarcisio; Dell'Acqua, Andrea; Dell'Asta, Lidia; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demirkoz, Bilge; Deng, Jianrong; Deng, Wensheng; Denisov, Sergey; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Deviveiros, Pier-Olivier; Dewhurst, Alastair; DeWilde, Burton; Dhaliwal, Saminder; Dhullipudi, Ramasudhakar; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Luise, Silvestro; Di Mattia, Alessandro; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Diaz, Marco Aurelio; Diblen, Faruk; Diehl, Edward; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Dindar Yagci, Kamile; Dingfelder, Jochen; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djilkibaev, Rashid; Djobava, Tamar; do Vale, Maria Aline Barros; Do Valle Wemans, André; Doan, Thi Kieu Oanh; Dobos, Daniel; Dobson, Ellie; Dobson, Marc; Doglioni, Caterina; Doherty, Tom; Dolejsi, Jiri; Dolenc, Irena; Dolezal, Zdenek; Dolgoshein, Boris; Dohmae, Takeshi; Donega, Mauro; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dos Anjos, Andre; Dotti, Andrea; Dova, Maria-Teresa; Doxiadis, Alexander; Doyle, Tony; Drasal, Zbynek; Dris, Manolis; Dubbert, Jörg; Duchovni, Ehud; Duckeck, Guenter; Dudarev, Alexey; Dudziak, Fanny; Dührssen , Michael; Duflot, Laurent; Dufour, Marc-Andre; Dunford, Monica; Duran Yildiz, Hatice; Duxfield, Robert; Dwuznik, Michal; Düren, Michael; Ebenstein, William; Ebke, Johannes; Eckweiler, Sebastian; Edmonds, Keith; Edwards, Clive; Egorov, Kirill; Ehrenfeld, Wolfgang; Ehrich, Thies; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Eisenhandler, Eric; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Katherine; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Engelmann, Roderich; Engl, Albert; Epp, Brigitte; Eppig, Andrew; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ermoline, Iouri; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Escobar, Carlos; Espinal Curull, Xavier; Esposito, Bellisario; Etienvre, Anne-Isabelle; Etzion, Erez; Evans, Hal; Fabbri, Laura; Fabre, Caroline; Facius, Katrine; Fakhrutdinov, Rinat; Falciano, Speranza; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farley, Jason; Farooque, Trisha; Farrington, Sinead; Farthouat, Philippe; Fassnacht, Patrick; Fassouliotis, Dimitrios; Fatholahzadeh, Baharak; Fayard, Louis; Fayette, Florent; Febbraro, Renato; Federic, Pavol; Fedin, Oleg; Fedorko, Woiciech; Feligioni, Lorenzo; Felzmann, Ulrich; Feng, Cunfeng; Feng, Eric; Fenyuk, Alexander; Ferencei, Jozef; Ferland, Jonathan; Fernandes, Bruno; Fernando, Waruna; Ferrag, Samir; Ferrando, James; Ferrara, Valentina; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferrer, Antonio; Ferrer, Maria Lorenza; Ferrere, Didier; Ferretti, Claudio; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filippas, Anastasios; Filthaut, Frank; Fincke-Keeler, Margret; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Gordon; Fisher, Matthew; Flechl, Martin; Fleck, Ivor; Fleckner, Johanna; Fleischmann, Philipp; Fleischmann, Sebastian; Flick, Tobias; Flores Castillo, Luis; Flowerdew, Michael; Fonseca Martin, Teresa; Fopma, Johan; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Fournier, Daniel; Fowler, Andrew; Fowler, Ken; Fox, Harald; Francavilla, Paolo; Franchino, Silvia; Francis, David; Franklin, Melissa; Franz, Sebastien; Fraternali, Marco; Fratina, Sasa; Freestone, Julian; French, Sky; Froeschl, Robert; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gadfort, Thomas; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Gallas, Elizabeth; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Galyaev, Eugene; Gan, K K; Gao, Yongsheng; Gaponenko, Andrei; Garcia-Sciveres, Maurice; García, Carmen; García Navarro, José Enrique; Gardner, Robert; Garelli, Nicoletta; Garitaonandia, Hegoi; Garonne, Vincent; Gatti, Claudio; Gaudio, Gabriella; Gautard, Valerie; Gauzzi, Paolo; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gazis, Evangelos; Ge, Peng; Gee, Norman; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Genest, Marie-Hélène; Gentile, Simonetta; Georgatos, Fotios; George, Simon; Gershon, Avi; Ghazlane, Hamid; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giakoumopoulou, Victoria; Giangiobbe, Vincent; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Adam; Gibson, Stephen; Gilbert, Laura; Gilchriese, Murdock; Gilewsky, Valentin; Gingrich, Douglas; Ginzburg, Jonatan; Giokaris, Nikos; Giordani, MarioPaolo; Giordano, Raffaele; Giorgi, Francesco Michelangelo; Giovannini, Paola; Giraud, Pierre-Francois; Girtler, Peter; Giugni, Danilo; Giusti, Paolo; Gjelsten, Børge Kile; Gladilin, Leonid; Glasman, Claudia; Glazov, Alexandre; Glitza, Karl-Walter; Glonti, George; Godfrey, Jennifer; Godlewski, Jan; Goebel, Martin; Göpfert, Thomas; Goeringer, Christian; Gössling, Claus; Göttfert, Tobias; Goggi, Virginio; Goldfarb, Steven; Goldin, Daniel; Golling, Tobias; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Gonçcalo, Ricardo; Gonella, Laura; Gong, Chenwei; González de la Hoz, Santiago; Gonzalez Silva, Laura; Gonzalez-Sevilla, Sergio; Goodson, Jeremiah Jet; Goossens, Luc; Gordon, Howard; Gorelov, Igor; Gorfine, Grant; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Gosdzik, Bjoern; Gosselink, Martijn; Gostkin, Mikhail Ivanovitch; Gough Eschrich, Ivo; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Grabowska-Bold, Iwona; Grafström, Per; Grahn, Karl-Johan; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Grau, Nathan; Gray, Heather; Gray, Julia Ann; Graziani, Enrico; Green, Barry; Greenshaw, Timothy; Greenwood, Zeno Dixon; Gregor, Ingrid-Maria; Grenier, Philippe; Griesmayer, Erich; Griffiths, Justin; Grigalashvili, Nugzar; Grillo, Alexander; Grimm, Kathryn; Grinstein, Sebastian; Grishkevich, Yaroslav; Groh, Manfred; Groll, Marius; Gross, Eilam; Grosse-Knetter, Joern; Groth-Jensen, Jacob; Grybel, Kai; Guicheney, Christophe; Guida, Angelo; Guillemin, Thibault; Guler, Hulya; Gunther, Jaroslav; Guo, Bin; Gurriana, Luis; Gusakov, Yury; Gutierrez, Andrea; Gutierrez, Phillip; Guttman, Nir; Gutzwiller, Olivier; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haas, Stefan; Haber, Carl; Hadavand, Haleh Khani; Hadley, David; Haefner, Petra; Haider, Stefan; Hajduk, Zbigniew; Hakobyan, Hrachya; Haller, Johannes; Hamacher, Klaus; Hamilton, Andrew; Hamilton, Samuel; Han, Liang; Hanagaki, Kazunori; Hance, Michael; Handel, Carsten; Hanke, Paul; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, John Renner; Hansen, Peter Henrik; Hansl-Kozanecka, Traudl; Hansson, Per; Hara, Kazuhiko; Hare, Gabriel; Harenberg, Torsten; Harrington, Robert; Harris, Orin; Harrison, Karl; Hartert, Jochen; Hartjes, Fred; Harvey, Alex; Hasegawa, Satoshi; Hasegawa, Yoji; Hassani, Samira; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawkes, Christopher; Hawkings, Richard John; Hayakawa, Takashi; Hayward, Helen; Haywood, Stephen; Head, Simon; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heinemann, Beate; Heisterkamp, Simon; Helary, Louis; Heller, Mathieu; Hellman, Sten; Helsens, Clement; Hemperek, Tomasz; Henderson, Robert; Henke, Michael; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Hensel, Carsten; Henß, Tobias; Hernández Jiménez, Yesenia; Hershenhorn, Alon David; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hessey, Nigel; Higón-Rodriguez, Emilio; Hill, John; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirsch, Florian; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoffman, Julia; Hoffmann, Dirk; Hohlfeld, Marc; Hollander, David; Holy, Tomas; Holzbauer, Jenny; Homma, Yasuhiro; Horazdovsky, Tomas; Hori, Takuya; Horn, Claus; Horner, Stephan; Hostachy, Jean-Yves; Hou, Suen; Hoummada, Abdeslam; Howe, Travis; Hrivnac, Julius; Hryn'ova, Tetiana; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Huang, Guang Shun; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Hurwitz, Martina; Husemann, Ulrich; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibragimov, Iskander; Iconomidou-Fayard, Lydia; Idarraga, John; Iengo, Paolo; Igonkina, Olga; Ikegami, Yoichi; Ikeno, Masahiro; Ilchenko, Yuri; Iliadis, Dimitrios; Ince, Tayfun; Ioannou, Pavlos; Iodice, Mauro; Irles Quiles, Adrian; Ishikawa, Akimasa; Ishino, Masaya; Ishmukhametov, Renat; Isobe, Tadaaki; Issever, Cigdem; Istin, Serhat; Itoh, Yuki; Ivashin, Anton; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, John; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakubek, Jan; Jana, Dilip; Jankowski, Ernest; Jansen, Eric; Jantsch, Andreas; Janus, Michel; Jarlskog, Göran; Jeanty, Laura; Jen-La Plante, Imai; Jenni, Peter; Jež, Pavel; Jézéquel, Stéphane; Ji, Weina; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Shan; Jinnouchi, Osamu; Joffe, David; Johansen, Marianne; Johansson, Erik; Johansson, Per; Johnert, Sebastian; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tim; Jorge, Pedro; Joseph, John; Juranek, Vojtech; Jussel, Patrick; Kabachenko, Vasily; Kaci, Mohammed; Kaczmarska, Anna; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kaiser, Steffen; Kajomovitz, Enrique; Kalinin, Sergey; Kalinovskaya, Lidia; Kama, Sami; Kanaya, Naoko; Kaneda, Michiru; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kaplon, Jan; Kar, Deepak; Karagounis, Michael; Karagoz, Muge; Karnevskiy, Mikhail; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasmi, Azzedine; Kass, Richard; Kastanas, Alex; Kastoryano, Michael; Kataoka, Mayuko; Kataoka, Yousuke; Katsoufis, Elias; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kayl, Manuel; Kayumov, Fred; Kazanin, Vassili; Kazarinov, Makhail; Keates, James Robert; Keeler, Richard; Keener, Paul; Kehoe, Robert; Keil, Markus; Kekelidze, George; Kelly, Marc; Kenyon, Mike; Kepka, Oldrich; Kerschen, Nicolas; Kerševan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Khakzad, Mohsen; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharchenko, Dmitri; Khodinov, Alexander; Khomich, Andrei; Khoriauli, Gia; Khovanskiy, Nikolai; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hyeon Jin; Kim, Min Suk; Kim, Peter; Kim, Shinhong; Kind, Oliver; Kind, Peter; King, Barry; Kirk, Julie; Kirsch, Guillaume; Kirsch, Lawrence; Kiryunin, Andrey; Kisielewska, Danuta; Kittelmann, Thomas; Kiyamura, Hironori; Kladiva, Eduard; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klemetti, Miika; Klier, Amit; Klimentov, Alexei; Klingenberg, Reiner; Klinkby, Esben; Klioutchnikova, Tatiana; Klok, Peter; Klous, Sander; Kluge, Eike-Erik; Kluge, Thomas; Kluit, Peter; Klute, Markus; Kluth, Stefan; Knecht, Neil; Kneringer, Emmerich; Ko, Byeong Rok; Kobayashi, Tomio; Kobel, Michael; Koblitz, Birger; Kocian, Martin; Kocnar, Antonin; Kodys, Peter; Köneke, Karsten; König, Adriaan; Koenig, Sebastian; Köpke, Lutz; Koetsveld, Folkert; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kohn, Fabian; Kohout, Zdenek; Kohriki, Takashi; Kolanoski, Hermann; Kolesnikov, Vladimir; Koletsou, Iro; Koll, James; Kollar, Daniel; Kolos, Serguei; Kolya, Scott; Komar, Aston; Komaragiri, Jyothsna Rani; Kondo, Takahiko; Kono, Takanori; Konoplich, Rostislav; Konovalov, Serguei; Konstantinidis, Nikolaos; Koperny, Stefan; Korcyl, Krzysztof; Kordas, Kostantinos; Korn, Andreas; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostka, Peter; Kostyukhin, Vadim; Kotov, Serguei; Kotov, Vladislav; Kotov, Konstantin; Kourkoumelis, Christine; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Henri; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, James; Kreisel, Arik; Krejci, Frantisek; Kretzschmar, Jan; Krieger, Nina; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Krumshteyn, Zinovii; Kubota, Takashi; Kuehn, Susanne; Kugel, Andreas; Kuhl, Thorsten; Kuhn, Dietmar; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kummer, Christian; Kuna, Marine; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurata, Masakazu; Kurochkin, Yurii; Kus, Vlastimil; Kwee, Regina; La Rosa, Alessandro; La Rotonda, Laura; Labbe, Julien; Lacasta, Carlos; Lacava, Francesco; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Rémi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Lamanna, Massimo; Lampen, Caleb; Lampl, Walter; Lancon, Eric; Landgraf, Ulrich; Landon, Murrough; Lane, Jenna; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Lanza, Agostino; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Larner, Aimee; Lassnig, Mario; Laurelli, Paolo; Lavrijsen, Wim; Laycock, Paul; Lazarev, Alexandre; Lazzaro, Alfio; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Menedeu, Eve; Lebedev, Alexander; Lebel, Céline; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lefebvre, Michel; Legendre, Marie; LeGeyt, Benjamin; Legger, Federica; Leggett, Charles; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leitner, Rupert; Lellouch, Daniel; Lellouch, Jeremie; Lendermann, Victor; Leney, Katharine; Lenz, Tatiana; Lenzen, Georg; Lenzi, Bruno; Leonhardt, Kathrin; Leroy, Claude; Lessard, Jean-Raphael; Lester, Christopher; Leung Fook Cheong, Annabelle; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Leyton, Michael; Li, Haifeng; Li, Xuefei; Liang, Zhihua; Liang, Zhijun; Liberti, Barbara; Lichard, Peter; Lichtnecker, Markus; Lie, Ki; Liebig, Wolfgang; Lilley, Joseph; Limosani, Antonio; Limper, Maaike; Lin, Simon; Linnemann, James; Lipeles, Elliot; Lipinsky, Lukas; Lipniacka, Anna; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Chuanlei; Liu, Dong; Liu, Hao; Liu, Jianbei; Liu, Minghui; Liu, Tiankuan; Liu, Yanwen; Livan, Michele; Lleres, Annick; Lloyd, Stephen; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Lockwitz, Sarah; Loddenkoetter, Thomas; Loebinger, Fred; Loginov, Andrey; Loh, Chang Wei; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Losada, Marta; Loscutoff, Peter; Lou, Xinchou; Lounis, Abdenour; Loureiro, Karina; Lovas, Lubomir; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Ludwig, Andreas; Ludwig, Dörthe; Ludwig, Inga; Luehring, Frederick; Lumb, Debra; Luminari, Lamberto; Lund, Esben; Lund-Jensen, Bengt; Lundberg, Björn; Lundberg, Johan; Lundquist, Johan; Lynn, David; Lys, Jeremy; Lytken, Else; Ma, Hong; Ma, Lian Liang; Macana Goia, Jorge Andres; Maccarrone, Giovanni; Macchiolo, Anna; Maček, Boštjan; Machado Miguens, Joana; Mackeprang, Rasmus; Madaras, Ronald; Mader, Wolfgang; Maenner, Reinhard; Maeno, Tadashi; Mättig, Peter; Mättig, Stefan; Magalhaes Martins, Paulo Jorge; Magradze, Erekle; Mahalalel, Yair; Mahboubi, Kambiz; Mahmood, A.; Maiani, Camilla; Maidantchik, Carmen; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makouski, Mikhail; Makovec, Nikola; Malecki, Piotr; Malecki, Pawel; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mambelli, Marco; Mameghani, Raphael; Mamuzic, Judita; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Mangeard, Pierre-Simon; Manhaes de Andrade Filho, Luciano; Manjavidze, Ioseb; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Mapelli, Alessandro; Mapelli, Livio; March , Luis; Marchand, Jean-Francois; Marchese, Fabrizio; Marchiori, Giovanni; Marcisovsky, Michal; Marino, Christopher; Marroquim, Fernando; Marshall, Zach; Marti-Garcia, Salvador; Martin, Alex; Martin, Andrew; Martin, Brian; Martin, Brian; Martin, Franck Francois; Martin, Jean-Pierre; Martin, Tim; Martin dit Latour, Bertrand; Martinez, Mario; Martinez Outschoorn, Verena; Martyniuk, Alex; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massol, Nicolas; Mastroberardino, Anna; Masubuchi, Tatsuya; Matricon, Pierre; Matsunaga, Hiroyuki; Matsushita, Takashi; Mattravers, Carly; Maxfield, Stephen; Mayne, Anna; Mazini, Rachid; Mazur, Michael; Mc Donald, Jeffrey; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCubbin, Norman; McFarlane, Kenneth; McGlone, Helen; Mchedlidze, Gvantsa; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Mechtel, Markus; Medinnis, Mike; Meera-Lebbai, Razzak; Meguro, Tatsuma; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Mendoza Navas, Luis; Meng, Zhaoxia; Menke, Sven; Meoni, Evelin; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Jean-Pierre; Meyer, Jochen; Meyer, Joerg; Meyer, Thomas Christian; Meyer, W. Thomas; Miao, Jiayuan; Michal, Sebastien; Micu, Liliana; Middleton, Robin; Migas, Sylwia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Miller, David; Miller, Michael; Mills, Corrinne; Mills, Bill; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Miñano, Mercedes; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Misawa, Shigeki; Misiejuk, Andrzej; Mitrevski, Jovan; Mitsou, Vasiliki A.; Miyagawa, Paul; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Moed, Shulamit; Moeller, Victoria; Mönig, Klaus; Möser, Nicolas; Mohr, Wolfgang; Mohrdieck-Möck, Susanne; Moles-Valls, Regina; Molina-Perez, Jorge; Monk, James; Monnier, Emmanuel; Montesano, Simone; Monticelli, Fernando; Moore, Roger; Mora Herrera, Clemencia; Moraes, Arthur; Morais, Antonio; Morel, Julien; Morello, Gianfranco; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morii, Masahiro; Morley, Anthony Keith; Mornacchi, Giuseppe; Morozov, Sergey; Morris, John; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Mudrinic, Mihajlo; Mueller, Felix; Mueller, James; Mueller, Klemens; Müller, Thomas; Muenstermann, Daniel; Muir, Alex; Munwes, Yonathan; Murillo Garcia, Raul; Murray, Bill; Mussche, Ido; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nadal, Jordi; Nagai, Koichi; Nagano, Kunihiro; Nagasaka, Yasushi; Nairz, Armin Michael; Nakamura, Koji; Nakano, Itsuo; Nakatsuka, Hiroki; Nanava, Gizo; Napier, Austin; Nash, Michael; Nation, Nigel; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Nderitu, Simon Kirichu; Neal, Homer; Nebot, Eduardo; Nechaeva, Polina; Negri, Andrea; Negri, Guido; Nelson, Andrew; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neusiedl, Andrea; Neves, Ricardo; Nevski, Pavel; Newcomer, Mitchel; Nickerson, Richard; Nicolaidou, Rosy; Nicolas, Ludovic; Nicoletti, Giovanni; Nicquevert, Bertrand; Niedercorn, Francois; Nielsen, Jason; Nikiforov, Andriy; Nikolaev, Kirill; Nikolic-Audit, Irena; Nikolopoulos, Konstantinos; Nilsen, Henrik; Nilsson, Paul; Nisati, Aleandro; Nishiyama, Tomonori; Nisius, Richard; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Nordberg, Markus; Nordkvist, Bjoern; Notz, Dieter; Novakova, Jana; Nozaki, Mitsuaki; Nožička, Miroslav; Nugent, Ian Michael; Nuncio-Quiroz, Adriana-Elizabeth; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Ochi, Atsuhiko; Oda, Susumu; Odaka, Shigeru; Odier, Jerome; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohshima, Takayoshi; Ohshita, Hidetoshi; Ohsugi, Takashi; Okada, Shogo; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olchevski, Alexander; Oliveira, Miguel Alfonso; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olivito, Dominick; Olszewski, Andrzej; Olszowska, Jolanta; Omachi, Chihiro; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlov, Iliya; Oropeza Barrera, Cristina; Orr, Robert; Ortega, Eduardo; Osculati, Bianca; Ospanov, Rustem; Osuna, Carlos; Ottersbach, John; Ould-Saada, Farid; Ouraou, Ahmimed; Ouyang, Qun; Owen, Mark; Owen, Simon; Oyarzun, Alejandro; Ozcan, Veysi Erkcan; Ozone, Kenji; Ozturk, Nurcan; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Paganis, Efstathios; Pahl, Christoph; Paige, Frank; Pajchel, Katarina; Palestini, Sandro; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Panes, Boris; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Panuskova, Monika; Paolone, Vittorio; Papadopoulou, Theodora; Park, Su-Jung; Park, Woochun; Parker, Andy; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pásztor , Gabriella; Pataraia, Sophio; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Peak, Lawrence; Pecsy, Martin; Pedraza Morales, Maria Isabel; Peleganchuk, Sergey; Peng, Haiping; Penson, Alexander; Penwell, John; Perantoni, Marcelo; Perez, Kerstin; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perez Reale, Valeria; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Persembe, Seda; Perus, Antoine; Peshekhonov, Vladimir; Petersen, Brian; Petersen, Troels; Petit, Elisabeth; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Petschull, Dennis; Petteni, Michele; Pezoa, Raquel; Phan, Anna; Phillips, Alan; Piacquadio, Giacinto; Piccinini, Maurizio; Piegaia, Ricardo; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinfold, James; Pinto, Belmiro; Pizio, Caterina; Placakyte, Ringaile; Plamondon, Mathieu; Pleier, Marc-Andre; Poblaguev, Andrei; Poddar, Sahill; Podlyski, Fabrice; Poggioli, Luc; Pohl, Martin; Polci, Francesco; Polesello, Giacomo; Policicchio, Antonio; Polini, Alessandro; Poll, James; Polychronakos, Venetios; Pomeroy, Daniel; Pommès, Kathy; Ponsot, Patrick; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Popule, Jiri; Portell Bueso, Xavier; Porter, Robert; Pospelov, Guennady; Pospisil, Stanislav; Potekhin, Maxim; Potrap, Igor; Potter, Christina; Potter, Christopher; Potter, Keith; Poulard, Gilbert; Poveda, Joaquin; Prabhu, Robindra; Pralavorio, Pascal; Prasad, Srivas; Pravahan, Rishiraj; Pribyl, Lukas; Price, Darren; Price, Lawrence; Prichard, Paul; Prieur, Damien; Primavera, Margherita; Prokofiev, Kirill; Prokoshin, Fedor; Protopopescu, Serban; Proudfoot, James; Prudent, Xavier; Przysiezniak, Helenka; Psoroulas, Serena; Ptacek, Elizabeth; Purdham, John; Purohit, Milind; Puzo, Patrick; Pylypchenko, Yuriy; Qi, Ming; Qian, Jianming; Qian, Weiming; Qin, Zhonghua; Quadt, Arnulf; Quarrie, David; Quayle, William; Quinonez, Fernando; Raas, Marcel; Radeka, Veljko; Radescu, Voica; Radics, Balint; Rador, Tonguc; Ragusa, Francesco; Rahal, Ghita; Rahimi, Amir; Rajagopalan, Srinivasan; Rammensee, Michael; Rammes, Marcus; Rauscher, Felix; Rauter, Emanuel; Raymond, Michel; Read, Alexander Lincoln; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Reinherz-Aronis, Erez; Reinsch, Andreas; Reisinger, Ingo; Reljic, Dusan; Rembser, Christoph; Ren, Zhongliang; Renkel, Peter; Rescia, Sergio; Rescigno, Marco; Resconi, Silvia; Resende, Bernardo; Reznicek, Pavel; Rezvani, Reyhaneh; Ribeiro, Nuno; Richards, Alexander; Richter, Robert; Richter-Was, Elzbieta; Ridel, Melissa; Rijpstra, Manouk; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Rios, Ryan Randy; Riu, Imma; Rizatdinova, Flera; Rizvi, Eram; Roa Romero, Diego Alejandro; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robinson, Mary; Robson, Aidan; Rocha de Lima, Jose Guilherme; Roda, Chiara; Roda Dos Santos, Denis; Rodriguez, Diego; Rodriguez Garcia, Yohany; Roe, Shaun; Røhne, Ole; Rojo, Victoria; Rolli, Simona; Romaniouk, Anatoli; Romanov, Victor; Romeo, Gaston; Romero Maltrana, Diego; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosenbaum, Gabriel; Rosselet, Laurent; Rossetti, Valerio; Rossi, Leonardo Paolo; Rotaru, Marina; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexander; Rozen, Yoram; Ruan, Xifeng; Ruckert, Benjamin; Ruckstuhl, Nicole; Rud, Viacheslav; Rudolph, Gerald; Rühr, Frederik; Ruggieri, Federico; Ruiz-Martinez, Aranzazu; Rumyantsev, Leonid; Rurikova, Zuzana; Rusakovich, Nikolai; Rutherfoord, John; Ruwiedel, Christoph; Ruzicka, Pavel; Ryabov, Yury; Ryan, Patrick; Rybkin, Grigori; Rzaeva, Sevda; Saavedra, Aldo; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvachua Ferrando, Belén; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Samset, Björn Hallvard; Sandaker, Heidi; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandhu, Pawan; Sandstroem, Rikard; Sandvoss, Stephan; Sankey, Dave; Sanny, Bernd; Sansoni, Andrea; Santamarina Rios, Cibran; Santoni, Claudio; Santonico, Rinaldo; Saraiva, João; Sarangi, Tapas; Sarkisyan-Grinbaum, Edward; Sarri, Francesca; Sasaki, Osamu; Sasao, Noboru; Satsounkevitch, Igor; Sauvage, Gilles; Savard, Pierre; Savine, Alexandre; Savinov, Vladimir; Sawyer, Lee; Saxon, David; Says, Louis-Pierre; Sbarra, Carla; Sbrizzi, Antonio; Scannicchio, Diana; Schaarschmidt, Jana; Schacht, Peter; Schäfer, Uli; Schaetzel, Sebastian; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R.~Dean; Schamov, Andrey; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schioppa, Marco; Schlenker, Stefan; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitz, Martin; Schöning, André; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schram, Malachi; Schreiner, Alexander; Schroeder, Christian; Schroer, Nicolai; Schroers, Marcel; Schultes, Joachim; Schultz-Coulon, Hans-Christian; Schumacher, Jan; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwemling, Philippe; Schwienhorst, Reinhard; Schwierz, Rainer; Schwindling, Jerome; Scott, Bill; Searcy, Jacob; Sedykh, Evgeny; Segura, Ester; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Seliverstov, Dmitry; Sellden, Bjoern; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Seuster, Rolf; Severini, Horst; Sevior, Martin; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shank, James; Shao, Qi Tao; Shapiro, Marjorie; Shatalov, Pavel; Shaw, Kate; Sherman, Daniel; Sherwood, Peter; Shibata, Akira; Shimojima, Makoto; Shin, Taeksu; Shmeleva, Alevtina; Shochet, Mel; Shupe, Michael; Sicho, Petr; Sidoti, Antonio; Siegert, Frank; Siegrist, James; Sijacki, Djordje; Silbert, Ohad; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simic, Ljiljana; Simion, Stefan; Simmons, Brinick; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skovpen, Kirill; Skubic, Patrick; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Sloper, John erik; Smakhtin, Vladimir; Smirnov, Sergei; Smirnov, Yuri; Smirnova, Lidia; Smirnova, Oxana; Smith, Ben Campbell; Smith, Douglas; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snow, Steve; Snow, Joel; Snuverink, Jochem; Snyder, Scott; Soares, Mara; Sobie, Randall; Sodomka, Jaromir; Soffer, Abner; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Solfaroli Camillocci, Elena; Solodkov, Alexander; Solovyanov, Oleg; Sondericker, John; Sopko, Vit; Sopko, Bruno; Sosebee, Mark; Soukharev, Andrey; Spagnolo, Stefania; Spanò, Francesco; Spighi, Roberto; Spigo, Giancarlo; Spila, Federico; Spiwoks, Ralf; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St. Denis, Richard Dante; Stahl, Thorsten; Stahlman, Jonathan; Stamen, Rainer; Stancu, Stefan Nicolae; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Stastny, Jan; Stavina, Pavel; Steele, Genevieve; Steinbach, Peter; Steinberg, Peter; Stekl, Ivan; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stevenson, Kyle; Stewart, Graeme; Stockton, Mark; Stoerig, Kathrin; Stoicea, Gabriel; Stonjek, Stefan; Strachota, Pavel; Stradling, Alden; Straessner, Arno; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Stroynowski, Ryszard; Strube, Jan; Stugu, Bjarne; Sturm, Philipp; Su, Dong; Soh, Dart-yin; Sugaya, Yorihito; Sugimoto, Takuya; Suhr, Chad; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Sushkov, Serge; Susinno, Giancarlo; Sutton, Mark; Suzuki, Takuya; Suzuki, Yu; Sykora, Ivan; Sykora, Tomas; Szymocha, Tadeusz; Sánchez, Javier; Ta, Duc; Tackmann, Kerstin; Taffard, Anyes; Tafirout, Reda; Taga, Adrian; Takahashi, Yuta; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Talby, Mossadek; Talyshev, Alexey; Tamsett, Matthew; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tapprogge, Stefan; Tardif, Dominique; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tassi, Enrico; Tatarkhanov, Mous; Taylor, Christopher; Taylor, Frank; Taylor, Geoffrey; Taylor, Ryan P.; Taylor, Wendy; Teixeira-Dias, Pedro; Ten Kate, Herman; Teng, Ping-Kun; Tennenbaum-Katan, Yaniv-David; Terada, Susumu; Terashi, Koji; Terron, Juan; Terwort, Mark; Testa, Marianna; Teuscher, Richard; Therhaag, Jan; Thioye, Moustapha; Thoma, Sascha; Thomas, Juergen; Thompson, Stan; Thompson, Emily; Thompson, Peter; Thompson, Paul; Thompson, Ray; Thomson, Evelyn; Thun, Rudolf; Tic, Tomas; Tikhomirov, Vladimir; Tikhonov, Yury; Tipton, Paul; Tique Aires Viegas, Florbela De Jes; Tisserant, Sylvain; Toczek, Barbara; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokár, Stanislav; Tokushuku, Katsuo; Tollefson, Kirsten; Tomasek, Lukas; Tomasek, Michal; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Tonoyan, Arshak; Topfel, Cyril; Topilin, Nikolai; Torchiani, Ingo; Torrence, Eric; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alesandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Trinh, Thi Nguyet; Tripiana, Martin; Triplett, Nathan; Trischuk, William; Trivedi, Arjun; Trocmé, Benjamin; Troncon, Clara; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiakiris, Menelaos; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsung, Jieh-Wen; Tsuno, Soshi; Tsybychev, Dmitri; Tuggle, Joseph; Tunnell, Christopher; Turecek, Daniel; Turk Cakir, Ilkay; Turlay, Emmanuel; Tuts, Michael; Twomey, Matthew Shaun; Tylmad, Maja; Tyndel, Mike; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ugland, Maren; Uhlenbrock, Mathias; Uhrmacher, Michael; Ukegawa, Fumihiko; Unal, Guillaume; Undrus, Alexander; Unel, Gokhan; Unno, Yoshinobu; Urbaniec, Dustin; Urkovsky, Evgeny; Urquijo, Phillip; Urrejola, Pedro; Usai, Giulio; Uslenghi, Massimiliano; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Vahsen, Sven; Valente, Paolo; Valentinetti, Sara; Valero, Alberto; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; Van Berg, Richard; van der Graaf, Harry; van der Kraaij, Erik; van der Poel, Egge; van der Ster, Daniel; van Eldik, Niels; van Gemmeren, Peter; van Kesteren, Zdenko; van Vulpen, Ivo; Vandelli, Wainer; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Vari, Riccardo; Varnes, Erich; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vasilyeva, Lidia; Vassilakopoulos, Vassilios; Vazeille, Francois; Vellidis, Constantine; Veloso, Filipe; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vetterli, Michel; Vichou, Irene; Vickey, Trevor; Viehhauser, Georg; Villa, Mauro; Villani, Giulio; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinek, Elisabeth; Vinogradov, Vladimir; Viret, Sébastien; Virzi, Joseph; Vitale , Antonio; Vitells, Ofer; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vlasak, Michal; Vlasov, Nikolai; Vogel, Adrian; Vokac, Petr; Volpi, Matteo; von der Schmitt, Hans; von Loeben, Joerg; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorwerk, Volker; Vos, Marcel; Voss, Rudiger; Voss, Thorsten Tobias; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vu Anh, Tuan; Vudragovic, Dusan; Vuillermet, Raphael; Vukotic, Ilija; Wagner, Peter; Walbersloh, Jorg; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Wang, Chiho; Wang, Haichen; Wang, Jin; Wang, Song-Ming; Warburton, Andreas; Ward, Patricia; Warsinsky, Markus; Wastie, Roy; Watkins, Peter; Watson, Alan; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Anthony; Waugh, Ben; Weber, Marc; Weber, Manuel; Weber, Michele; Weber, Pavel; Weidberg, Anthony; Weingarten, Jens; Weiser, Christian; Wellenstein, Hermann; Wells, Phillippa; Wenaus, Torre; Wendler, Shanti; Weng, Zhili; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Werth, Michael; Werthenbach, Ulrich; Wessels, Martin; Whalen, Kathleen; White, Andrew; White, Martin; White, Sebastian; Whitehead, Samuel Robert; Whiteson, Daniel; Whittington, Denver; Wicek, Francois; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik, Liv Antje Mari; Wildauer, Andreas; Wildt, Martin Andre; Wilkens, Henric George; Williams, Eric; Williams, Hugh; Willocq, Stephane; Wilson, John; Wilson, Michael Galante; Wilson, Alan; Wingerter-Seez, Isabelle; Winklmeier, Frank; Wittgen, Matthias; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wraight, Kenneth; Wright, Catherine; Wright, Dennis; Wrona, Bozydar; Wu, Sau Lan; Wu, Xin; Wulf, Evan; Wynne, Benjamin; Xaplanteris, Leonidas; Xella, Stefania; Xie, Song; Xu, Da; Xu, Neng; Yamada, Miho; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamaoka, Jared; Yamazaki, Takayuki; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Un-Ki; Yang, Zhaoyu; Yao, Weiming; Yao, Yushu; Yasu, Yoshiji; Ye, Jingbo; Ye, Shuwei; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Riktura; Young, Charles; Youssef, Saul; Yu, Dantong; Yu, Jaehoon; Yuan, Li; Yurkewicz, Adam; Zaidan, Remi; Zaitsev, Alexander; Zajacova, Zuzana; Zambrano, Valentina; Zanello, Lucia; Zaytsev, Alexander; Zeitnitz, Christian; Zeller, Michael; Zemla, Andrzej; Zendler, Carolin; Zenin, Oleg; Ženiš, Tibor; Zenonos, Zenonas; Zenz, Seth; Zerwas, Dirk; Zevi della Porta, Giovanni; Zhan, Zhichao; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Qizhi; Zhang, Xueyao; Zhao, Long; Zhao, Tianchi; Zhao, Zhengguo; Zhemchugov, Alexey; Zhong, Jiahang; Zhou, Bing; Zhou, Ning; Zhou, Yue; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Yingchun; Zhuang, Xuai; Zhuravlov, Vadym; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Ziolkowski, Michael; Živković, Lidija; Zobernig, Georg; Zoccoli, Antonio; zur Nedden, Martin; Zutshi, Vishnu

    2010-01-01

    The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the detector successfully collected data from the LHC single beams in 2008 and first collisions in 2009. This paper gives an overview of the Tile Calorimeter performance as measured using random triggers, calibration data, data from cosmic ray muons and single beam data. The detector operation status, noise characteristics and performance of the calibration systems are presented, as well as the validation of the timing and energy calibration carried out with minimum ionising cosmic ray muons data. The calibration systems' precision is well below the design of 1%. The determination of the global energy scale was performed with an uncertainty of 4%.

  10. The New Readout System of the NA62 LKr Calorimeter

    CERN Document Server

    Ceccucci, A; Farthouat, P; Lamanna, G; Rouet, J; Ryjov, V; Venditti, S

    2015-01-01

    The NA62 experiment [1] at CERN SPS (Super Proton Synchrotron) accelerator aims at studying Kaon decays with high precision. The high resolution Liquid Krypton (LKr) calorimeter, built for the NA48 [2] experiment, is a crucial part of the photon-veto system; to cope with the demanding NA62 re- quirements,itsback-endelectron icshadtobecompletelyrenewed. The new readout system is based on the Calorimeter REAdout Module (CREAM) [3], a 6U VME board whose design and pro- duction was sub-contracted to CAEN [4], with CERN NA62 group continuously supervising the de velopment and production phase. The first version of the board was delivered by the manufacturer in March 2013 and, as of June 2014, the full board production is ongoing. In addition to describing the CREAM board, all aspects of the new LKr readout system, including its integration within the NA62 TDAQ scheme, will be treated.

  11. Geometric calibration of the SND detector electromagnetic calorimeter

    CERN Document Server

    Korol, A A

    2016-01-01

    This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the Spherical Neutral Detector (SND) which is used for HEP experiments at the VEPP-2000 $e^{+}e^{-}$ collider (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position. The parameter values are determined by minimizing a $\\chi^{2}$ function using the difference between directions reconstructed in these two subdetectors for the $e^{+}e^{-}\\rightarrow e^{+}e^{-}$ scattering data events. The results of the calibration and its application to the data and MC simulation fit the model and give an improvement of the reconstructed particle parameters. They are used already in the actual experimental data analysis and more realistic MC simulation. We think that the ideas implemented in the calibration procedure can be useful for other experiments with hete...

  12. Advanced Mixed Waste Treatment Project melter system preliminary design technical review meeting

    Energy Technology Data Exchange (ETDEWEB)

    Eddy, T.L.; Raivo, B.D.; Soelberg, N.R.; Wiersholm, O.

    1995-02-01

    The Idaho National Engineering Laboratory Advanced Mixed Waste Treatment Project sponsored a plasma are melter technical design review meeting to evaluate high-temperature melter system configurations for processing heterogeneous alpha-contaminated low-level radioactive waste (ALLW). Thermal processing experts representing Department of Energy contractors, the Environmental Protection Agency, and private sector companies participated in the review. The participants discussed issues and evaluated alternative configurations for three areas of the melter system design: plasma torch melters and graphite arc melters, offgas treatment options, and overall system configuration considerations. The Technical Advisory Committee for the review concluded that graphite arc melters are preferred over plasma torch melters for processing ALLW. Initiating involvement of stakeholders was considered essential at this stage of the design. For the offgas treatment system, the advisory committee raised the question whether to a use wet-dry or a dry-wet system. The committee recommended that the waste stream characterization, feed preparation, and the control system are essential design tasks for the high-temperature melter treatment system. The participants strongly recommended that a complete melter treatment system be assembled to conduct tests with nonradioactive surrogate waste material. A nonradioactive test bed would allow for inexpensive design and operational changes prior to assembling a system for radioactive waste treatment operations.

  13. Advanced Mixed Waste Treatment Project melter system preliminary design technical review meeting

    International Nuclear Information System (INIS)

    The Idaho National Engineering Laboratory Advanced Mixed Waste Treatment Project sponsored a plasma are melter technical design review meeting to evaluate high-temperature melter system configurations for processing heterogeneous alpha-contaminated low-level radioactive waste (ALLW). Thermal processing experts representing Department of Energy contractors, the Environmental Protection Agency, and private sector companies participated in the review. The participants discussed issues and evaluated alternative configurations for three areas of the melter system design: plasma torch melters and graphite arc melters, offgas treatment options, and overall system configuration considerations. The Technical Advisory Committee for the review concluded that graphite arc melters are preferred over plasma torch melters for processing ALLW. Initiating involvement of stakeholders was considered essential at this stage of the design. For the offgas treatment system, the advisory committee raised the question whether to a use wet-dry or a dry-wet system. The committee recommended that the waste stream characterization, feed preparation, and the control system are essential design tasks for the high-temperature melter treatment system. The participants strongly recommended that a complete melter treatment system be assembled to conduct tests with nonradioactive surrogate waste material. A nonradioactive test bed would allow for inexpensive design and operational changes prior to assembling a system for radioactive waste treatment operations

  14. Applying fast calorimetry on a spent nuclear fuel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Liljenfeldt, Henrik [Swedish Nuclear Fuel and Waste Management (Sweden); Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Uppsala Univ. (Sweden)

    2015-04-15

    Recently at Los Alamos National Laboratory, sophisticated prediction algorithms have been considered for the use of calorimetry for treaty verification. These algorithms aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy. The algorithms have been implemented in MATLAB and applied on existing equilibrium measurements from a spent nuclear fuel calorimeter located at the Swedish nuclear fuel interim storage facility. The results show significant improvements in measurement time in the order of 15 to 50 compared to equilibrium measurements, but cannot predict the heat accurately in less time than the currently used temperature increase method can. This Is both due to uncertainties in the calibration of the method as well as identified design features of the calorimeter that limits the usefulness of equilibrium type measurements. The conclusions of these findings are discussed, and suggestions of both improvements of the current calorimeter as well as what to keep in mind in a new design are given.

  15. Applying fast calorimetry on a spent nuclear fuel calorimeter

    International Nuclear Information System (INIS)

    Recently at Los Alamos National Laboratory, sophisticated prediction algorithms have been considered for the use of calorimetry for treaty verification. These algorithms aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy. The algorithms have been implemented in MATLAB and applied on existing equilibrium measurements from a spent nuclear fuel calorimeter located at the Swedish nuclear fuel interim storage facility. The results show significant improvements in measurement time in the order of 15 to 50 compared to equilibrium measurements, but cannot predict the heat accurately in less time than the currently used temperature increase method can. This Is both due to uncertainties in the calibration of the method as well as identified design features of the calorimeter that limits the usefulness of equilibrium type measurements. The conclusions of these findings are discussed, and suggestions of both improvements of the current calorimeter as well as what to keep in mind in a new design are given.

  16. The ATLAS tile calorimeter ROD injector and multiplexer board

    International Nuclear Information System (INIS)

    The ATLAS Tile Calorimeter is a sampling detector composed by cells made of iron-scintillator tiles. The calorimeter cell signals are digitized in the front-end electronics and transmitted to the Read-Out Drivers (RODs) at the first level trigger rate. The ROD receives triggered data from up to 9856 channels and provides the energy, phase and quality factor of the signals to the second level trigger. The back-end electronics is divided into four partitions containing eight RODs each. Therefore, a total of 32 RODs are used to process and transmit the data of the TileCal detector. In order to emulate the detector signals in the production and commissioning of ROD modules a board called ROD Injector and Multiplexer Board (RIMBO) was designed. In this paper, the RIMBO main functional blocks, PCB design and the different operation modes are described. It is described the crucial role of the board within the TileCal ROD test-bench in order to emulate the front-end electronics during the validation of ROD boards as well as during the evaluation of the ROD signal reconstruction algorithms. Finally, qualification and performance results for the injection operation mode obtained during the Tile Calorimeter ROD production tests are presented.

  17. DIRAC v2 a DIgital Readout Asic for hadronic Calorimeter

    CERN Document Server

    Gaglione, R; Chefdeville, M; Drancourt, C; Vouters, G

    2009-01-01

    DIRAC is a 64 channel mixed-signal readout integrated circuit designed for Micro-Pattern Gaseous Detectors (MICROMEGAS, Gas Electron Multiplier) or Resistive Plate Chambers. These detectors are foreseen as the active part of a digital hadronic calorimeter for a high energy physics experiment at the International Linear Collider. Physic requirements lead to a highly granular hadronic calorimeter with up to thirty million channels with probably only hit information (digital calorimeter). The DIRAC ASIC has been especially designed for these constraints. Each channel of the DIRAC chip is made of a 4 gains charge preamplifier, a DC-servo loop, 3 switched comparators and a digital memory, thus providing additional energy information for a hit. A bulk MICROMEGAS detector with embedded DIRAC v1 ASIC has been built. The tests of this assembly, both in laboratory with X-Rays and in a beam at CERN are presented, demonstrating the feasibility of a bulk MICROMEGAS detector with embedded electronics. The second version of...

  18. Construction and Tests of the Mechanical Structure for a Semi-Digital Hadronic Calorimeter Prototype within the CALICE Collaboration

    International Nuclear Information System (INIS)

    The assembly of a mechanical structure used for a semi-digital hadronic calorimeter prototype, conceived and developed by the SDHCAL group within the CALICE collaboration, is presented in this note. CALICE is an international R and D collaboration dedicated to the development of calorimeters for future linear collider experiments. The design, assembly and quality control of this mechanical structure were entirely carried out at CIEMAT. This document contains a description of the prototype and its detectors, focusing on the design and assembly of the mechanical structure, which acts as well as the calorimeter absorber.. (Author)

  19. Buckling design criteria for waste package disposal containers in mined salt repositories: Technical report

    International Nuclear Information System (INIS)

    This report documents analytical and experimental results from a survey of the technical literature on buckling of thick-walled cylinders under external pressure. Based upon these results, a load factor is suggested for the design of waste package containers for disposal of high-level radioactive waste in repositories mined in salt formations. The load factor is defined as a ratio of buckling pressure to allowable pressure. Specifically, a load factor which ranges from 1.5 for plastic buckling to 3.0 for elastic buckling is included in a set of proposed buckling design criteria for waste disposal containers. Formulas are given for buckling design under axisymmetric conditions. Guidelines are given for detailed inelastic buckling analyses which are generally required for design of disposal containers

  20. Development of technical design for waste processing and storage facilities for Novi Han repository

    International Nuclear Information System (INIS)

    Empresarion Agrupados Internacional S.A. (Spain) and ENPRO Consult Ltd. (Bulgaria) were awarded a contract by the Central Finance and Contracts Unit to develop the technical design of the waste processing and storage facilities at the Novi Han repository. At present conceptual design phase is finished. This conceptual design covers the definition of the basic design requirements to be applied to the installations defined above, following both European and Bulgarian legislation. In this paper the following items are considered: 1) Basic criteria for the layout and sizing of buildings; 2) Processing of radioactive waste, including: treatment and conditioning of disused sealed sources; treatment of liquid radioactive wastes; treatment of solid radioactive waste; conditioning of liquid and solid radioactive waste; 3) Control of waste packages and 4) Storage of radioactive waste, including storage facility and waste packages. An analysis of inventories of stored and estimated future wastes and its subsequent processes is also presented and the waste streams are illustrated

  1. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...... material are the radiation stability of this material and the fact that identical phantoms can be made for irradiation of other dosimeters for calibration. This provides a precise tool for establishing traceability of dose measurements at industrial electron electron accelerators....

  2. Calorimeter prediction based on multiple exponentials

    Energy Technology Data Exchange (ETDEWEB)

    Smith, M.K. E-mail: mks@lanl.gov; Bracken, D.S

    2002-05-21

    Calorimetry allows very precise measurements of nuclear material to be carried out, but it also requires relatively long measurement times to do so. The ability to accurately predict the equilibrium response of a calorimeter would significantly reduce the amount of time required for calorimetric assays. An algorithm has been developed that is effective at predicting the equilibrium response. This multi-exponential prediction algorithm is based on an iterative technique using commercial fitting routines that fit a constant plus a variable number of exponential terms to calorimeter data. Details of the implementation and the results of trials on a large number of calorimeter data sets will be presented.

  3. Calorimeter prediction based on multiple exponentials

    International Nuclear Information System (INIS)

    Calorimetry allows very precise measurements of nuclear material to be carried out, but it also requires relatively long measurement times to do so. The ability to accurately predict the equilibrium response of a calorimeter would significantly reduce the amount of time required for calorimetric assays. An algorithm has been developed that is effective at predicting the equilibrium response. This multi-exponential prediction algorithm is based on an iterative technique using commercial fitting routines that fit a constant plus a variable number of exponential terms to calorimeter data. Details of the implementation and the results of trials on a large number of calorimeter data sets will be presented

  4. Calorimeter prediction based on multiple exponentials

    CERN Document Server

    Smith, M K

    2002-01-01

    Calorimetry allows very precise measurements of nuclear material to be carried out, but it also requires relatively long measurement times to do so. The ability to accurately predict the equilibrium response of a calorimeter would significantly reduce the amount of time required for calorimetric assays. An algorithm has been developed that is effective at predicting the equilibrium response. This multi-exponential prediction algorithm is based on an iterative technique using commercial fitting routines that fit a constant plus a variable number of exponential terms to calorimeter data. Details of the implementation and the results of trials on a large number of calorimeter data sets will be presented.

  5. ALICE Zero Degree Calorimeter (ZDC), General Pictures.

    CERN Multimedia

    2003-01-01

    The ZDC Calorimeter for spectator neutrons is made by 44 slabs of W-alloy; each slab has 44 grooves where quartz fibres are placed. The charged particles of the hadronic shower generated by the neutrons make Cerenkov light in the fibres and the light is collected by photomultipliers. Photos from 1 to 9 show the front-face of the calorimeter. Photo n. 10 shows the rear of the calorimeter where the fibres are divided in several groups to go to the different PMs.

  6. Benchmarking Design: Multiplying the Impact of Technical Assistance to MSMEs in Design and Product Development

    OpenAIRE

    Del Giorgio Solfa, Federico

    2012-01-01

    This work takes as challenge-level exploratory study in the importance, scope and dimensions of the benchmarking of product design for the state advisory in design and product development for micro, small and medium producers. The initiative falls as the zero phase of the project made for the Admission to the Research Career of Scientific and Technological Research Commission of the Province of Buenos Aires (CIC-PBA), which is under evaluation. Our approach comprises the sub-national po...

  7. The LHCb hadron calorimeter prototype

    International Nuclear Information System (INIS)

    LHCb is a Large Hadron Collider Beauty experiment dedicated for precision measurements of CP violation and rare phenomena. The experiment is built as a single arm detector covering a forward angle between ∼ 15 mrad and ∼ 300 mrad. It consists in a vertex detector, a tracking system, two RICH detectors, a calorimeter system comprising a preshower, electromagnetic and hadron sections, and a muon system. The role of the calorimeters is to provide identification of the electrons and hadrons for trigger and offline analysis with measurements of position and energy. The hadron calorimeter (HCAL) has to provide data for the trigger and to assist in background suppression when B decays are reconstructed. In 1997 an HCAL prototype stack of 3 modules, each having the dimensions 96 x 16 x 153 cm3, has been constructed and exposed to the X7 test beams of the SPS at CERN. Each module is constructed from scintillator tiles embedded in an iron structure, which are parallel to the beam direction in a staggered arrangement. The cell segmentation of the 1997 prototype was 16 x 16 cm2 and had a 2-fold in depth readout. Around 3760 spacer plates and weld straps necessary for all 6 modules were supplied by Romanian group of IFIN-HH in 1997, as well as about 200 master plates for two modules in 1998. The assembling of the modules was performed at CERN by people of our group, IHEP Serpukhov and CERN. During November 1997 test beam data were taken with pion and electron beams of 5 up to 50 GeV/c momenta. The energy spectra for pions were obtained. A shift of about 1.3 GeV of the energy mean value with respect to the beam energy was observed for all studied energies. This could be due to different effects. The energy resolution as a function of the beam energy fitted by the dependence σ/E = a/√E + b gives parameters in agreement with the values expected from Monte Carlo. Uniformity response for pions at 20 GeV oscillates within 2.5 % around the mean value. Data taken with ECAL

  8. Tritium calorimeter setup and operation

    CERN Document Server

    Rodgers, D E

    2002-01-01

    The LBNL tritium calorimeter is a stable instrument capable of measuring tritium with a sensitivity of 25 Ci. Measurement times range from 8-hr to 7-days depending on the thermal conductivity and mass of the material being measured. The instrument allows accurate tritium measurements without requiring that the sample be opened and subsampled, thus reducing personnel exposure and radioactive waste generation. The sensitivity limit is primarily due to response shifts caused by temperature fluctuation in the water bath. The fluctuations are most likely a combination of insufficient insulation from ambient air and precision limitations in the temperature controller. The sensitivity could probably be reduced to below 5 Ci if the following improvements were made: (1) Extend the external insulation to cover the entire bath and increase the top insulation. (2) Improve the seal between the air space above the bath and the outside air to reduce evaporation. This will limit the response drift as the water level drops. (...

  9. High-speed superconducting x-ray calorimeter using a transition edge sensor

    International Nuclear Information System (INIS)

    A high-speed superconducting x-ray calorimeter that uses a transition edge sensor (TES) was developed and tested for industrial applications such as microanalysis used in the semiconductor industry. The calorimeter consisted of a Au/Ti bilayer TES formed on a bridge-type SiNx membrane. A count rate of at least 10 000 cps was achieved by designing the calorimeter to have a decay time constant of less than 16 μs. Preliminary experiments involved using the calorimeter (cooled by using a 3He refrigerator with a base temperature below 350 mK) to detect heat pulses and x-rays. To evaluate the response of the calorimeter, we measured the dependence of the decay time constant on the bias current, the pulse height of a heat pulse and the current noise. At the optimal bias point, the calorimeter showed a measured decay time constant of 15 μs and a pulse height of 4 μA when detecting x-rays. (author)

  10. Arrival of the last cryostat for the ATLAS LAr calorimeter at CERN

    CERN Multimedia

    Aleksa, M; Oberlack, H

    On Wednesday, 4th June the last cryostat for the ATLAS LAr calorimeter (end-cap A) arrived at CERN and was immediately unloaded from the truck in building 180 (see Figures 1 and 2), where the integration of the LAr calorimeters into their cryostats takes place. The transport from the Italian company SIMIC, where both end-cap calorimeters have been produced took longer than expected due to delays because of the G8 summit. Thanks to the great effort by the CERN Host State office and the French-German steering group that supplies the end-cap cryostat as an in-kind contribution to the LAr collaboration, an exceptional convoy was finally available and the cryostat could make its way to CERN. Fig.1 (left): Truck with the end-cap cryostat. Fig.2 (right): Unloading the cryostat in bldg. 180. Each end-cap cryostat will contain an electromagnetic calorimeter wheel, two wheels of a hadronic calorimeter, and a forward calorimeter. The design of the cryostat as a double vessel structure made of Aluminum fulfills t...

  11. Calorimeter for detection of hadrons in the energy range 10-100 GeV

    International Nuclear Information System (INIS)

    The calorimeter for hadron detection in the energy range 10-100 GeV is described. It is used at CERN in the experiment NA58 (COMPASS) designed to study the nucleon structure and charmed particle spectroscopy. The calorimeter consists of 480 modules (15 x 15 cm in cross section, interaction length 4.8) assembled in matrix 4.2 x 3 m with a central hole of 1.2 x 0.6 m. The energy resolutions of the calorimeter for hadrons (σπ) and electrons (σe) as well as coordinate resolution (σx,y) have been determined in the test beams to be (σπ(E))/E = (59.4 ± 2.9)/√E O+(7.6 ± 0.4), (σe(E))/E = (24.6 ± 0.7)/√E O+ (0.7 ± 0.4), σx,y = (14 ± 2) mm, respectively. The average ratio, characterizing the amplitude responses of the calorimeter to electrons and pions, has been measured to be e/π = 1.2 ± 0.1. The calorimeter is used to measure hadron energy and as an element of the COMPASS trigger system. The calorimeter has been working stably during the long COMPASS runs with characteristics close to those determined in the test beams. (author)

  12. Social-technical design for evaluation of student's behaviour and expectations

    DEFF Research Database (Denmark)

    John, Claudette; Kampf, Constance Elizabeth; Briollet, Alexandra;

    2015-01-01

    This paper focuses on the usability of new technologies and real-time socio-technical features for evaluation issues in student’s courses. The evaluation of content and forms of knowledge taught within a course are directly linked to behaviour, perception and expectations from the student’s side....... So, we focus here on the evaluation process based on socio-technical design that allows integrating student’s behaviour and expectations. A Web App has been constructed and tested on an exploratory basis to get real-time insights about the combination of theory, course and practical applications. The...... results demonstrate a very high participation ratio from the student’s side. This is due to the use of smartphones that are directly integrated in their social life contexts. Therefore, real-time statistics can be used for improving the quality of teaching or practical applications on a continual basis...

  13. The development of mini gamma calorimeter. Analysis of the calorimeter characteristic using analytical method

    International Nuclear Information System (INIS)

    The development of mini gamma calorimeter. Analysis of the calorimeter characteristic using analytical method. To increase the gamma calorimeter capability, especially to obtain the new type of calorimeter that can be used at high power reactor, it is necessary to find out an innovation of the existing calorimeter model. The basic idea of the innovation is to eliminate the absorber material which restricts the performance of the old calorimeter. As the first step of innovation, characteristics of this mini calorimeter without absorber will be analyzed by analytical method in the static condition. The analysis was performed for several combinations of geometries and dimensions of active parts as well as those of gas isolations. The calculation results showed that the sensitivity (as a principal characteristic) of the calorimeter of 30oC per W/g is acceptable value, and the active length of 2 cm with the diameter of 1 mm of thermocouples (active part) is the optimum geometry. According to the results, it can be concluded that the mini gamma calorimeter proposed is reasonable to be made

  14. The technical specification for seismic analysis for CNS facilities and the basic design for CNS instrument island

    International Nuclear Information System (INIS)

    This report details the technical specification on seismic analysis for CNS system facilities and the basic design for CNS instrument island which will be installed in the HANARO reactor building. The technical specification on seismic analysis describes the classification of a seismic category, the procedure of a seismic analysis, and the requirements of a seismic design. The design response spectrum for SSE and OBE are presented for the seismic analysis for seismic category I. The technical specification on the seismic analysis includes the procedure for FEM modelling, modal analysis, time history analysis for generation of floor response spectrum, response spectrum analysis. The CNS instrument islands is classified as the seismic category I. Basic design drawings and requirements for ensuring the location and the conceptual shape of CNS instrument islands were developed considering the design interface of as-built installed structures. Based on the basic design and the results of field measurements the detail design of CNS instrument islands will be carried out

  15. Modelling of Water Cooled Fuel Including Design Basis and Severe Accidents. Proceedings of a Technical Meeting

    International Nuclear Information System (INIS)

    The demands on nuclear fuel have recently been increasing, and include transient regimes, higher discharge burnup and longer fuel cycles. This has resulted in an increase of loads on fuel and core internals. In order to satisfy these demands while ensuring compliance with safety criteria, new national and international programmes have been launched and advanced modelling codes are being developed. The Fukushima Daiichi accident has particularly demonstrated the need for adequate analysis of all aspects of fuel performance to prevent a failure and also to predict fuel behaviour were an accident to occur.This publication presents the Proceedings of the Technical Meeting on Modelling of Water Cooled Fuel Including Design Basis and Severe Accidents, which was hosted by the Nuclear Power Institute of China (NPIC) in Chengdu, China, following the recommendation made in 2013 at the IAEA Technical Working Group on Fuel Performance and Technology. This recommendation was in agreement with IAEA mid-term initiatives, linked to the post-Fukushima IAEA Nuclear Safety Action Plan, as well as the forthcoming Coordinated Research Project (CRP) on Fuel Modelling in Accident Conditions. At the technical meeting in Chengdu, major areas and physical phenomena, as well as types of code and experiment to be studied and used in the CRP, were discussed. The technical meeting provided a forum for international experts to review the state of the art of code development for modelling fuel performance of nuclear fuel for water cooled reactors with regard to steady state and transient conditions, and for design basis and early phases of severe accidents, including experimental support for code validation. A round table discussion focused on the needs and perspectives on fuel modelling in accident conditions. This meeting was the ninth in a series of IAEA meetings, which reflects Member States’ continuing interest in nuclear fuel issues. The previous meetings were held in 1980 (jointly with

  16. Upgrading the ATLAS fast calorimeter simulation

    CERN Document Server

    Hubacek, Zdenek; The ATLAS collaboration

    2016-01-01

    Many physics and performance studies with the ATLAS detector at the Large Hadron Collider require very large samples of simulated events, and producing these using the full GEANT4 detector simulation is highly CPU intensive. Often, a very detailed detector simulation is not needed, and in these cases fast simulation tools can be used to reduce the calorimeter simulation time. In ATLAS, a fast simulation of the calorimeter systems was developed, called Fast Calorimeter Simulation (FastCaloSim). It provides a parametrized simulation of the particle energy response at the calorimeter read-out cell level. It is interfaced to the standard ATLAS digitization and reconstruction software, and can be tuned to data more easily than with GEANT4. An improved parametrization is being developed, to eventually address shortcomings of the original version. It makes use of statistical techniques such as principal component analysis, and a neural network parametrization to optimise the amount of information to store in the ATL...

  17. Measurements Made by Vinca-Calorimeters

    International Nuclear Information System (INIS)

    A cross section of the Vinca-Heat-Flow calorimeter is shown. The sample container (10 mm diameter, 50 mm high, 0.25 mm. wall thickness) is centred in the jacket (48 mm diameter, 100 mm high, 2 mm wall thickness) by styrofoam which acts as the homogeneous heat transfer medium. The calibration heater, a coil wound on a thin hollow paper cylinder is placed inside the sample container. The temperature difference between the sample container and the jacket was measured with a copper-constantan thermocouple. The lid served also as a support to which the cable was fastened. Two calorimeters were constructed. Particular attention was paid to counterbalance the mass of aluminium capsules (better than 1% of the weight). In one calorimeter the sample container was empty (the ''empty'' calorimeter) in the other one a known mass of graphite was placed

  18. Magnetic micro-calorimeters for neutrino physics

    International Nuclear Information System (INIS)

    Metallic magnetic micro-calorimeters are energy dispersive detectors operated at temperatures below 0.1 Kelvin. Their resolving power E/ ΔE approaching 5000, the intrinsic response time well below 1 μs and the excellent linearity make magnetic micro-calorimeters very attractive for numerous experiments. With such detectors we have performed the first high resolution calorimetric measurements of the 163Ho electron capture spectrum. The achieved performance motivated the formation of the international collaboration ECHo (Electron Capture in 163Ho) to investigate the electron neutrino mass in the sub-eV range using the 163Ho. For the search of neutrinoless double beta decay in 100Mo with scintillating crystals, we have developed photon and phonon detectors based on metallic magnetic calorimeters to be used in the experiments AMoRE and LUMINEU. In this talk, the ECHo experiment as well as the other applications of metallic magnetic calorimeters for neutrino physics will be discussed.

  19. The CMS central hadron calorimeter: Update

    International Nuclear Information System (INIS)

    The CMS central hadron calorimeter is a brass absorber/ scintillator sampling structure. We describe details of the mechanical and optical structure. We also discuss calibration techniques, and finally the anticipated construction schedule

  20. Status and perspecitves of liquid argon calorimeters

    International Nuclear Information System (INIS)

    The status of liquid argon calorimeters is reviewed, and experience obtained with these devices is described. Future perspectives of the liquid ionization chamber technique in calorimetry are also discussed. (orig.)

  1. The Visible and Infrared Survey Telescope for Astronomy (VISTA): Design, Technical Overview and Performance

    CERN Document Server

    Sutherland, Will; Dalton, Gavin; Atad-Ettedgui, Eli; Beard, Steven; Bennett, Richard; Bezawada, Naidu; Born, Andrew; Caldwell, Martin; Clark, Paul; Craig, Simon; Henry, David; Jeffers, Paul; Little, Bryan; McPherson, Alistair; Murray, John; Stewart, Malcolm; Stobie, Brian; Terrett, David; Ward, Kim; Whalley, Martin; Woodhouse, Guy

    2014-01-01

    The Visible and Infrared Survey Telescope for Astronomy (VISTA) is the 4-metre wide-field survey telescope at ESO's Paranal Observatory, equipped with the world's largest near-infrared imaging camera (VISTA IR Camera, VIRCAM), with 1.65 degree diameter field of view, and 67 Mpixels giving 0.6 square degrees active pixel area, operating at wavelengths 0.8 - 2.3 microns. We provide a short history of the project, and an overview of the technical details of the full system including the optical design, mirrors, telescope structure, IR camera, active optics, enclosure and software. The system includes several innovative design features such as the f/1 primary mirror, the cold-baffle camera design and the sophisticated wavefront sensing system delivering closed-loop 5-axis alignment of the secondary mirror. We conclude with a summary of the delivered performance, and a short overview of the six ESO public surveys in progress on VISTA.

  2. Cosmic muon tomography of pure cesium iodide calorimeter crystals

    International Nuclear Information System (INIS)

    Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the π+→π0e+νe decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were examined in a multiwire drift chamber system specially designed for transmission cosmic muon tomography. Critical elements of the apparatus and reconstruction algorithms enabling measurement of spatial detector optical nonuniformities are described. Results are compared with a Monte Carlo simulation of the light response of an ideal detector. The deduced optical nonuniformity contributions to the FWHM energy resolution of the PIBETA CsI calorimeter for the π+→e+ν 69.8 MeV positrons and the monoenergetic 70.8 MeV photons were 2.7% and 3.7%, respectively. The upper limit of optical nonuniformity correction to the 69.8 MeV positron low-energy tail between 5 and 55 MeV was +0.2%, as opposed to the +0.3% tail contribution for the photon of the equivalent total energy. Imposing the 5 MeV calorimeter veto cut to suppress the electromagnetic losses, GEANT-evaluated positron and photon lineshape tail fractions summed over all above-threshold ADCs were found to be 2.36±0.05 (stat) ±0.20 (sys)% and 4.68±0.07 (stat)±0.20 (sys)%, respectively

  3. The backward end-cap for the PANDA electromagnetic calorimeter

    Science.gov (United States)

    Capozza, L.; Maas, F. E.; Noll, O.; Rodriguez Pineiro, D.; Valente, R.

    2015-02-01

    The PANDA experiment at the new FAIR facility will cover a broad experimental programme in hadron structure and spectroscopy. As a multipurpose detector, the PANDA spectrometer needs to ensure almost 4π coverage of the scattering solid angle, full and accurate multiple-particle event reconstruction and very good particle identification capabilities. The electromagnetic calorimeter (EMC) will be a key item for many of these aspects. Particle energies ranging from some MeVs to several GeVs have to be measured with a relative resolution of 1% ⊕ 2%/√E/GeV . It will be a homogeneous calorimeter made of PbWO4 crystals and will be operated at -25°C, in order to improve the scintillation light yield. With the exception of the very forward section, the light will be detected by large area avalanche photodiodes (APDs). The current pulses from the APDs will be integrated, amplified and shaped by ASIC chips which were developed for this purpose. The whole calorimeter has been designed in three sections: a forward end-cap, a central barrel and a backward end-cap (BWEC). In this contribution, a status report on the development of the BWEC is presented.

  4. The CDF calorimeter upgrade for RunIIb

    CERN Document Server

    Huston, J; Kuhlmann, S; Lami, S; Miller, R; Paoletti, R; Turini, N; Ukegawa, F

    2004-01-01

    The physics program at the Fermilab Tevatron Collider will continue to explore the high energy elementary particle physics until the LHC commissioning. The upgrade of the CDF calorimeter opens a new window for improving the jet energy resolution, important in finding various signals such as Higgs by correcting the energy loss in the dead material and adding information in the jet algorithms using charged particles. It plays an important role in soft electron tagging of b- jets and photon identification in SUSY. The upgrade of the CDF calorimeter includes: a) the replacement of slow gas detector on the front face of the Central Calorimeter with Preshower (CPR) based on 2cm thick scintillator tiles segmented in eta and Phi and read out by WLS fibers running into a groove on the surface of each tiles. The WLS fibers are placed to clear fibers after leaving the tiles; b) the replacement of the Central Crack Chamber (CCR) with 5mm thick scintillator tiles read with the same technique: To finalize the design parame...

  5. Calibration of the CALICE analog hadronic calorimeter (AHCAL)

    International Nuclear Information System (INIS)

    The CALICE AHCAL technological prototype is a hadronic calorimeter prototype for a future e+e- - collider (ILC and CLIC). It is designed as a sampling calorimeter alternating tungsten or steel absorber plates and active readout layers, segmented in single plastic scintillator tiles of 3 x 3 x 0.3 cm3 volume. Each tile is individually coupled to a silicon photomultiplier, read out by a dedicated ASIC with energy measurement and time stamping capability. The high granularity is meant to enable imaging and separation of single showers, for a Particle Flow approach to the jet energy measurement. The prototype aims to establish this technology as a scalable solution for an ILC detector. The first 14 layers of this prototype have been assembled and commissioned. The first 10 layers in the stack are used as tracker to determine the position of the first hard interaction of a pion shower in the first interaction length (λ) of the calorimeter. Four full size layers (72 x 72 cm2) are distributed between 1 and 3λ depth in the steel absorber. Data has been collected with muon, electron and pion beams at the CERN PS (2014). The first results on energy calibration with muons are presented, together with a comparison to the bench calibration obtained during tile production.

  6. The calorimeter project for the Mu2e experiment

    Energy Technology Data Exchange (ETDEWEB)

    Budagov, J. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Carosi, R.; Cervelli, F. [INFN, Pisa (Italy); Cheng, C. [California Institute of Technology, Pasadena, CA (United States); Cordelli, M. [Laboratori Nazionali di Frascati, INFN, Frascati (Italy); Davydov, Yu. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Downie, E.J. [The George Washington University, Washington DC (United States); Echenard, B. [California Institute of Technology, Pasadena, CA (United States); Giovannella, S. [Laboratori Nazionali di Frascati, INFN, Frascati (Italy); Glagolev, V. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Happacher, F. [Laboratori Nazionali di Frascati, INFN, Frascati (Italy); Hitlin, D. [California Institute of Technology, Pasadena, CA (United States); Lucà, A., E-mail: alessandra.luca@lnf.infn.it [Laboratori Nazionali di Frascati, INFN, Frascati (Italy); Miscetti, S. [Laboratori Nazionali di Frascati, INFN, Frascati (Italy); Ongmonkolkul, P. [California Institute of Technology, Pasadena, CA (United States); Onorato, G. [INFN, Lecce (Italy); Otte, P. [Johannes Gutenberg Universität, Mainz (Germany); Pezzullo, G. [INFN, Pisa (Italy); Pileggi, G. [Laboratori Nazionali di Frascati, INFN, Frascati (Italy); Porter, F. [California Institute of Technology, Pasadena, CA (United States); and others

    2013-08-01

    The Mu2e experiment at Fermilab aims to measure the charged lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the rest mass of the muon (104.97 MeV). We expect to set a limit of ∼ 6×10 {sup −17} at 90% CL in three years of running, using an intense and clean pulsed μ{sup −} beam providing ∼ 10 {sup 18} stopped muons on target in three years of running. The experiment performs a strong suppression of potential background by gating off the prompts and performing precise momentum determination in conjunction with an highly efficient cosmic veto. The calorimeter should confirm that the candidates reconstructed by the tracker system are indeed conversion electrons and provide an independent trigger (or event reduction filter) for the experiment. It should also provide standalone muon to electron rejection. Moreover, it must be able to keep functionality in a high radiation dose environment inside a 10 {sup −4}torr vacuum enclosure and in a presence of 1 T axial magnetic field. In order to accomplish all these tasks, a LYSO crystals calorimeter has been chosen. We show the proposed design and the experimental results obtained by exposing a small size calorimeter prototype to a tagged photon beam from 40 to 300 MeV at the A2 photon facility of the Mainz Microton (MAMI), Germany.

  7. Results on the LHCb hadron calorimeter prototype

    International Nuclear Information System (INIS)

    , Imax = 20 mA; 2) two types of multichannel HV distributors with an individual voltage setting within 512 V range; 3) a software package to control all settings and refresh them periodically. A new design for a HV power supply system which satisfies the LHC requirements is in progress. The main goal of the beam tests was to measure in beam intrinsic properties of the calorimeter like resolution, response uniformity, signal time properties, shower lateral dimensions and to decide upon the cell size and depth of the hadron calorimeter. The measured energy, angular and coordinate dependences of the HCAL response and resolution were found to correspond to the LHCb design requirements. The resolution as function of the beam energy for two prototype depths of 7.3 λ (5 modules) and 5.6 λ ia shown. The angular and X-Y coordinate uniformity have been checked and compared with stand-alone Monte-Carlo simulation program predictions. A good uniformity within the total angle range has been observed. The average hadronic shower profile on both X- and Y-directions obtained from the scan data are presented. (authors)

  8. Micro-Fabricated DC Comparison Calorimeter for RF Power Measurement

    Directory of Open Access Journals (Sweden)

    Bilel Neji

    2014-10-01

    Full Text Available Diode detection and bolometric detection have been widely used to measure radio frequency (RF power. However, flow calorimeters, in particular micro-fabricated flow calorimeters, have been mostly unexplored as power meters. This paper presents the design, micro-fabrication and characterization of a flow calorimeter. This novel device is capable of measuring power from 100 \\(\\mu\\W to 200 mW. It has a 50-Ohm load that is heated by the RF source, and the heat is transferred to fluid in a microchannel. The temperature change in the fluid is measured by a thermistor that is connected in one leg of a Wheatstone bridge. The output voltage change of the bridge corresponds to the RF power applied to the load. The microfabricated device measures 25.4 mm \\(\\times\\ 50.8 mm, excluding the power supplies, microcontroller and fluid pump. Experiments demonstrate that the micro-fabricated sensor has a sensitivity up to 22 \\(\\times\\ \\(10^{-3}\\ V/W. The typical resolution of this micro-calorimeter is on the order of 50 \\(\\mu\\W, and the best resolution is around 10 \\(\\mu\\W. The effective efficiency is 99.9\\% from 0–1 GHz and more than 97.5\\% at frequencies up to 4 GHz. The measured reflection coefficient of the 50-Ohm load and coplanar wave guide is less than \\(-25\\ dB from 0–2 GHz and less than \\(-16\\ dB at 2–4 GHz.

  9. The NA48 liquid krypton calorimeter

    CERN Document Server

    Gorini, B

    1997-01-01

    The NA48 collaboration goal is to measure the CP violation parameter Re(ɛl/ɛ) at the level of 2 × 10−4. The neutral Kaon decays will be reconstructed by an electromagnetic liquid Krypton calorimeter with fine granularity and a volume almost totally sensible, to obtain excellent position and energy resolution, as well as time resolution. A description of the detector, results from tests of a prototype and the status of the final calorimeter are reported.

  10. Heavy ion studies with CMS HF calorimeter

    International Nuclear Information System (INIS)

    The capability of the very forward (HF) calorimeter of the CMS detector at LHC to be applied to specific studies with heavy ion beams is discussed. The simulated responses of the HF calorimeter to nucleus-nucleus collisions are used for the analysis of different problems: reconstruction of the total energy flow in the forward rapidity region, accuracy of determination of the impact parameter of collision, study of fluctuations of the hadronic-to-electromagnetic energy ratio, fast inelastic event selection

  11. Proportional model calorimeters of the TPC facility

    International Nuclear Information System (INIS)

    Two wire proportional mode gas calorimeter modules have been tested as prototypes for the Pole Tip calorimeters of the TPC Facility at PEP. The results of the tests at several electron energies (0.25 to 12. GeV) and several pressures (1.0 to 30. atms) are presented, comparisons with a detailed simulation program are made, and results from the Pole Tip modules now operating at PEP are given

  12. Design, Manufacturing and Irradiation Behaviour of Fast Reactor Fuel. Proceedings of a Technical Meeting

    International Nuclear Information System (INIS)

    Fast reactors are vital for ensuring the sustainability of nuclear energy in the long term. They offer vastly more efficient use of uranium resources and the ability to burn actinides, which are otherwise the long-lived component of high level nuclear waste. These reactors require development, qualification, testing and deployment of improved and innovative nuclear fuel and structural materials having very high radiation resistance, corrosion/erosion and other key operational properties. Several IAEA Member States have made efforts to advance the design and manufacture of technologies of fast reactor fuels, as well as to investigate their irradiation behaviour. Due to the acute shortage of fast neutron testing and post-irradiation examination facilities and the insufficient understanding of high dose radiation effects, there is a need for international exchange of knowledge and experience, generation of currently missing basic data, identification of relevant mechanisms of materials degradation and development of appropriate models. Considering the important role of nuclear fuels in fast reactor operation, the IAEA Technical Working Group on Fuel Performance and Technology (TWGFPT) proposed a Technical Meeting (TM) on 'Design, Manufacturing and Irradiation Behaviour of Fast Reactors Fuels', which was hosted by the Institute of Physics and Power Engineering (IPPE) in Obninsk, Russian Federation, from 30 May to 3 June 2011. The TM included a technical visit to the fuel production plant MSZ in Elektrostal. The purpose of the meeting was to provide a forum to share knowledge, practical experience and information on the improvement and innovation of fuels for fast reactors through scientific presentations and brainstorming discussions. The meeting brought together 34 specialists from national nuclear agencies, R and D and design institutes, fuel vendors and utilities from 10 countries. The presentations were structured into four sections: R and D Programmes on FR Fuel

  13. Technical evaluation of a CAD system for orthopaedic shoe-upper design.

    Science.gov (United States)

    Lord, M; Foulston, J; Smith, P J

    1991-01-01

    Computer aided design is now employed routinely in the volume shoe trade. New styles are developed on a three-dimensional image of the last followed by automated pattern generation and engineering. It is suggested that such systems could be useful in the orthopaedic footwear industry although the different requirements for these bespoke products need careful consideration. A clinical trial has been conducted on the Shoemaster (Clarks Shoes) upper design system both to assess its technical capabilities and to consider its role in improvement of service and cosmetic appearance. This particular system works throughout on a three-dimensional representation of the shoe last, which offers particular advantages for integration with shape capture and reproduction. The report concentrates on the technical evaluation to assess (a) its ability to work with unusual last shapes dictated by medical requirements and (b) its potential for integration into a complete computer system for design of both shoe lasts and shoe uppers. The trial indicates that this particular system is promising in both respects. PMID:1840716

  14. Last Few Metres for the Barrel Calorimeter

    CERN Multimedia

    Nyman, T.

    On Friday 4th November, the ATLAS Barrel Calorimeter was moved from its assembly point at the side of the ATLAS cavern to the centre of the toroidal magnet system. The detector was finally aligned, to the precision of within a millimetre, on Wednesday 9th November. The ATLAS installation team, led by Tommi Nyman, after having positioned the Barrel Calorimeter in its final location in the ATLAS experimental cavern UX15. The Barrel Calorimeter which will absorb and measure the energy of photons, electrons and hadrons at the core of the ATLAS detector is 8.6 meters in diameter, 6.8 meters long, and weighs over 1600 Tonnes. It consists of two concentric cylindrical detector elements. The innermost comprises aluminium pressure vessels containing the liquid argon electromagnetic calorimeter and the solenoid magnet. The outermost is an assembly of 64 hadron tile calorimeter sectors. Assembled 18 meters away from its final position, the Barrel Calorimeter was relocated with the help of a railway, which allows ...

  15. ATLAS: last few metresfor the Calorimeter

    CERN Multimedia

    2005-01-01

    On Friday 4th November, the ATLAS Barrel Calorimeter was moved from its assembly point at the side of the ATLAS cavern to the centre of the toroidal magnet system. The detector was finally aligned, to the precision of within a millimetre, on Wednesday 9th November. The ATLAS installation team, led by Tommi Nyman, after having positioned the Barrel Calorimeter in its final location in the ATLAS experimental cavern UX15. The Barrel Calorimeter which will absorb and measure the energy of photons, electrons and hadrons at the core of the ATLAS detector is 8.6 meters in diameter, 6.8 meters long, and weighs over 1600 Tonnes. It consists of two concentric cylindrical detector elements. The innermost comprises aluminium pressure vessels containing the liquid argon electromagnetic calorimeter and the solenoid magnet. The outermost is an assembly of 64 hadron tile calorimeter sectors. Assembled 18 meters away from its final position, the Barrel Calorimeter was relocated with the help of a railway, which allows the ...

  16. Design and implementation of the control system for nuclear plant VVER-1000. Instrumentation (program technical complexes)

    International Nuclear Information System (INIS)

    Program-technical complexes (PTC) are designed as control and protection systems in water-moderated atomic reactors, including emergency and preventive systems, automatic control, unloading, reactor capacity limitation and accelerated preventive protection systems. Utilization of programmable logic integrated circuits from world leading manufacturers makes the complexes simple in structure, compact, with low energy demands and mutually independent for key and supporting functions The results of PTC assessment and implementation in Ukraine are outlined. Opportunities for a future development of RADIJ company in the area of control and protection systems for VVER reactors are also discussed

  17. Nuclear waste calorimeter for very large drums with 385 litres sample volume

    Energy Technology Data Exchange (ETDEWEB)

    Jossens, G.; Mathonat, C. [SETARAM Instrumentation, Caluire (France); Bachelet, F. [CEA Valduc, Is sur Tille (France)

    2015-03-15

    Calorimetry is a very precise and well adapted tool for the classification of drums containing nuclear waste material depending on their level of activities (low, medium, high). A new calorimeter has been developed by SETARAM Instrumentation and the CEA Valduc in France. This new calorimeter is designed for drums having a volume bigger than 100 liters. It guarantees high operator safety by optimizing drum handling and air circulation for cooling, and optimized software for direct measurement of the quantity of nuclear material. The LVC1380 calorimeter makes it possible to work over the range 10 to 3000 mW, which corresponds to approximately 0.03 to 10 g of tritium or 3 to 955 g of {sup 241}Pu in a volume up to 385 liters. This calorimeter is based on the heat flow measurement using Peltier elements which surround the drum in the 3 dimensions and therefore measure all the heat coming from the radioactive stuff whatever its position inside the drum. Calorimeter's insulating layers constitute a thermal barrier designed to filter disturbances until they represent less than 0.001 Celsius degrees and to eliminate long term disturbances associated, for example, with laboratory temperature variations between day and night. A calibration device based on Joule effect has also been designed. Measurement time has been optimized but remains long compared with other methods of measurement such as gamma spectrometry but its main asset is to have a good accuracy for low level activities.

  18. Technical evaluation report on the proposed design modifications and technical specification changes on grid voltage degradation for the Millstone Nuclear Power Station, Unit 1

    International Nuclear Information System (INIS)

    This report documents the technical evaluation of the proposed design modifications and Technical Specification change for protection of Class 1E equipment from grid voltage degradation for the Millstone Nuclear Power Station, Unit 1. The review criteria are based on several IEEE standards and the Code of Federal Regulations. The evaluation finds that the licensee has not provided sufficient information on the undervoltage protection system to allow a complete evaluation into the adequacy of protecting the Class 1E equipment from sustained voltage degradation

  19. Bon voyage to the hadronic calorimeter

    CERN Multimedia

    2006-01-01

    It was a grand entourage for the first half of the CMS hadronic forward calorimeter (HF) that was escorted to Cessy, France by the police on 11 July. The impressive trailer carrying the 7-m-long and 4-m-wide element was pushed and pulled by two specially designed trucks. It took the 64-m-long convoy around 5 hours to travel the 15 km to its final destination. The days leading up to this operation involved intensive checks to the balance and pressure of the hydraulic system of the trailer's wheels. As one side of the HF is slightly heavier than the other, it is crucial to take this into account when transporting such a massive object (each half of the HF weighs 260 tonnes). However, once these checks were complete, the transport was safely underway. The second half of the HF also received a police escort on 18 July as it made its way to the assembly hall at Point 5. The HF will be the first major detector to be lowered into the CMS cavern via the gantry crane in the coming months.

  20. Evolution of the dual-readout calorimeter

    Indian Academy of Sciences (India)

    Aldo Penzo; on behalf of 4th Concept and DREAM

    2007-12-01

    Measuring the energy of hadronic jets with high precision is essential at present and future colliders, in particular at ILC. The 4th concept design is built upon calorimetry criteria that result in the DREAM prototype, read-out via two different types of longitudinal fibers, scintillator and quartz respectively, and therefore capable of determining for each shower the corresponding electromagnetic fraction, thus eliminating the strong effect of fluctuations in this fraction on the overall energy resolution. In this respect, 4th is orthogonal to the other three concepts, which rely on particle flow analysis (PFA). The DREAM test-beam results hold promises for excellent performances, coupled with relatively simple construction and moderate costs, making such a solution an interesting alternative to the PFA paradigm. The next foreseen steps are to extend the dual-readout principle to homogeneous calorimeters (with the potential of achieving even better performances) and to tackle another source of fluctuation in hadronic showers, originating from binding energy losses in nuclear break-up (measuring neutrons of few MeV energy).

  1. Technical Support Document: The Development of the Advanced Energy Design Guide for Highway Lodging Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Jarnagin, Ronald E.; Gowri, Krishnan; McBride, M.; Liu, Bing

    2008-09-30

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Highway Lodgings (AEDG-HL or the Guide), a design guidance document intended to provide recommendations for achieving 30% energy savings in highway lodging properties over levels contained in ANSI/ASHRAE/IESNA Standard 90.1-1999, Energy Standard for Buildings Except Low-Rise Residential Buildings. The AEDG-HL is the fifth in a series of guides being developed by a partnership of organizations, including the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IESNA), the United States Green Buildings Council (USGBC), and the U.S. Department of Energy (DOE).

  2. Next Generation Nuclear Plant (NGNP) Prismatic HTGR Conceptual Design Project - Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Saurwein, John

    2011-07-15

    This report is the Final Technical Report for the Next Generation Nuclear Plant (NGNP) Prismatic HTGR Conceptual Design Project conducted by a team led by General Atomics under DOE Award DE-NE0000245. The primary overall objective of the project was to develop and document a conceptual design for the Steam Cycle Modular Helium Reactor (SC-MHR), which is the reactor concept proposed by General Atomics for the NGNP Demonstration Plant. The report summarizes the project activities over the entire funding period, compares the accomplishments with the goals and objectives of the project, and discusses the benefits of the work. The report provides complete listings of the products developed under the award and the key documents delivered to the DOE.

  3. Next Generation Nuclear Plant (NGNP) Prismatic HTGR Conceptual Design Project - Final Technical Report

    International Nuclear Information System (INIS)

    This report is the Final Technical Report for the Next Generation Nuclear Plant (NGNP) Prismatic HTGR Conceptual Design Project conducted by a team led by General Atomics under DOE Award DE-NE0000245. The primary overall objective of the project was to develop and document a conceptual design for the Steam Cycle Modular Helium Reactor (SC-MHR), which is the reactor concept proposed by General Atomics for the NGNP Demonstration Plant. The report summarizes the project activities over the entire funding period, compares the accomplishments with the goals and objectives of the project, and discusses the benefits of the work. The report provides complete listings of the products developed under the award and the key documents delivered to the DOE.

  4. Staff Technical Position on consideration of fault displacement hazards in geologic repository design

    International Nuclear Information System (INIS)

    Nuclear Regulatory Commission regulations for the disposal of spent nuclear fuel and high-level radioactive waste in a geologic repository recognize that fault displacement is a potentially adverse condition. However, they do not prohibit designing the geologic repository against the effects of such a potentially adverse condition. This Staff Technical Position recognizes the acceptability of designing the geologic repository to take into account the attendant effects (e.g., displacement) of faults of regulatory concern and expresses the staff's views on what is needed from the US Department of Energy if it chooses to locate structures, systems, and components important to safety or important to waste isolation in areas that contain faults of regulatory concern

  5. A liquid hydrogen target for the calibration of the MEG and MEG II liquid xenon calorimeter

    Science.gov (United States)

    Signorelli, G.; Baldini, A. M.; Bemporad, C.; Cei, F.; Nicolò, D.; Galli, L.; Gallucci, G.; Grassi, M.; Papa, A.; Sergiampietri, F.; Venturini, M.

    2016-07-01

    We designed, built and operated a liquid hydrogen target for the calibration of the liquid xenon calorimeter of the MEG experiment. The target was used throughout the entire data taking period, from 2008 to 2013 and it is being refurbished and partly re-designed to be integrated and used in the MEG-II experiment.

  6. Control, Test and Monitoring Software Framework for the ATLAS Level-1 Calorimeter Trigger

    CERN Document Server

    Achenbach, R; Aharrouche, M; Andrei, V; Åsman, B; Barnett, B M; Bauss, B; Bendel, M; Bohm, C; Booth, J R A; Bracinik, J; Brawn, I P; Charlton, D G; Childers, J T; Collins, N J; Curtis, C J; Davis, A O; Eckweiler, S; Eisenhandler, E F; Faulkner, P J W; Fleckner, J; Föhlisch, F; Gee, C N P; Gillman, A R; Goringer, C; Groll, M; Hadley, D R; Hanke, P; Hellman, S; Hidvegi, A; Hillier, S J; Johansen, M; Kluge, E E; Kühl, T; Landon, M; Lendermann, V; Lilley, J N; Mahboubi, K; Mahout, G; Meier, K; Middleton, R P; Moa, T; Morris, J D; Müller, F; Neusiedl, A; Ohm, C; Oltmann, B; Perera, V J O; Prieur, D P F; Qian, W; Rieke, S; Rühr, F; Sankey, D P C; Schäfer, U; Schmitt, K; Schultz-Coulon, H C; Silverstein, S; Sjölin, J; Staley, R J; Stamen, R; Stockton, M C; Tan, C L A; Tapprogge, S; Thomas, J P; Thompson, P D; Watkins, P M; Watson, A; Weber, P; Wessels, M; Wildt, M

    2008-01-01

    The ATLAS first-level calorimeter trigger is a hardware-based system designed to identify high-pT jets, electron/photon and tau candidates and to measure total and missing ET in the ATLAS calorimeters. The complete trigger system consists of over 300 customdesignedVME modules of varying complexity. These modules are based around FPGAs or ASICs with many configurable parameters, both to initialize the system with correct calibrations and timings and to allow flexibility in the trigger algorithms. The control, testing and monitoring of these modules requires a comprehensive, but well-designed and modular, software framework, which we will describe in this paper.

  7. The spaghetti calorimeter. Research, development, application

    Energy Technology Data Exchange (ETDEWEB)

    Scheel, C.V.

    1994-12-22

    The Spaghetti Calorimeter (SPACAL) is a detector intended primarily for the energy measurement of high-energy particles, but also provides spatial information and particle identification. It is a sampling calorimeter composed of plastic scintillating fibers, oriented in the direction of the particle, embedded in lead. The scintillation light is read out by photomultipliers, which are coupled to bunches of fibers through light guides, each forming a tower. It was developed as an electromagnetic (e.m.) and compensating hadronic calorimeter for use in future multi-TeV collider experiments. The largest prototype was installed for an alternative application as an hadronic calorimeter in the WA89 experiment, where it is used for the detection of neutrons resulting from {Sigma} decays. The basic concepts behind calorimetry are discussed in detail. Several prototypes were tested in beams of electrons and pions with energies up to 150 GeV. Resonable e.m. energy resolution, at {sigma}/E=12.9%/{radical}E[GeV]+1.23%, was measured. Excellent hadronic energy resolution was found, at 30.6%/{radical}E[GeV]+1.0%, but the calorimeter was found to be slightly undercompensating with e/h=1.15. The position of the shower barycenter for both electrons and pions was easily found according to the relative energy deposits in the calorimeter towers. The calorimeter was also found to be able to provide effective discrimination between electrons and hadrons. The performance of SPACAL in the WA89 experiment at the Omega spectrometer at CERN was studied with the reconstruction of beam {Sigma}{sup -}particles via its decay {Sigma}{sup -}{yields}n{pi}{sup -}. Details of the calibration of SPACAL with electrons and protons are presented. (orig.).

  8. The spaghetti calorimeter. Research, development, application

    International Nuclear Information System (INIS)

    The Spaghetti Calorimeter (SPACAL) is a detector intended primarily for the energy measurement of high-energy particles, but also provides spatial information and particle identification. It is a sampling calorimeter composed of plastic scintillating fibers, oriented in the direction of the particle, embedded in lead. The scintillation light is read out by photomultipliers, which are coupled to bunches of fibers through light guides, each forming a tower. It was developed as an electromagnetic (e.m.) and compensating hadronic calorimeter for use in future multi-TeV collider experiments. The largest prototype was installed for an alternative application as an hadronic calorimeter in the WA89 experiment, where it is used for the detection of neutrons resulting from Σ decays. The basic concepts behind calorimetry are discussed in detail. Several prototypes were tested in beams of electrons and pions with energies up to 150 GeV. Resonable e.m. energy resolution, at σ/E=12.9%/√E[GeV]+1.23%, was measured. Excellent hadronic energy resolution was found, at 30.6%/√E[GeV]+1.0%, but the calorimeter was found to be slightly undercompensating with e/h=1.15. The position of the shower barycenter for both electrons and pions was easily found according to the relative energy deposits in the calorimeter towers. The calorimeter was also found to be able to provide effective discrimination between electrons and hadrons. The performance of SPACAL in the WA89 experiment at the Omega spectrometer at CERN was studied with the reconstruction of beam Σ-particles via its decay Σ-→nπ-. Details of the calibration of SPACAL with electrons and protons are presented. (orig.)

  9. The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Mkrtchyan, Hamlet [Yerevan Physics Institute, JLAB; Carlini, Roger D. [JLAB; Tadevosyan, Vardan H. [Yerevan Physics Institute; Arrington, John Robert [ANL; Asaturyan, Arshak Razmik [Yerevan Physics Institute; Christy, Michael Eric [Hampton U.; Dutta, Dipangkar [Mississippi State U.; Ent, Rolf [JLAB; Fenker, Howard C. [JLAB; Gaskell, David J. [JLAB; Horn, Tanja [Catholic University of America, JLAB; Jones, Mark K. [JLAB; Keppel, Cynthia [JLAB, Hampton U.; Mack, David J. [JLAB; Malace, Simona P. [Triangle Universities Nuclear Laboratory and Duke University; Mkrtchyan, Arthur [Yerevan Physics Institute; Niculescu, Maria-Ioana [James Madison U.; Seely, Charles Jason [MIT; Tvaskis, Vladas [University of Manitoba; Wood, Stephen A. [JLAB; Zhamkochyan, Simon [Yerevan Physics Institute

    2013-08-01

    The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $\\sigma/E \\sim 6%/\\sqrt E $, and pion/electron ($\\pi/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $\\pi^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.

  10. Performance of an endcap prototype of the ATLAS accordion electromagnetic calorimeter

    CERN Document Server

    Gingrich, D M; Boos, E; Zhautykov, B O; Aubert, Bernard; Bazan, A; Beaugiraud, B; Boniface, J; Colas, Jacques; Jézéquel, S; Le Flour, T; Maire, M; Rival, F; Stipcevic, M; Thion, J; Van den Plas, D; Wingerter-Seez, I; Zitoun, R; Zolnierowski, Y; Chmeissani, M; Fernández, E; Garrido, L; Martínez, M; Padilla, C; Gordon, H A; Radeka, V; Rahm, David Charles; Stephani, D; Baisin, L; Berset, J C; Chevalley, J L; Gianotti, F; Gildemeister, O; Marin, C P; Nessi, Marzio; Poggioli, Luc; Richter, W; Vuillemin, V; Baze, J M; Gosset, L G; Lavocat, P; Lottin, J P; Mansoulié, B; Meyer, J P; Renardy, J F; Schwindling, J; Teiger, J; Collot, J; de Saintignon, P; Dzahini, D; Hostachy, J Y; Laborie, G; Mahout, G; Merchez, E; Pouxe, J; Hervás, L; Labarga, L; Scheel, C V; Chekhtman, A; Dargent, P; Dinkespiler, B; Etienne, F; Fassnacht, P; Fouchez, D; Martin, L; Martin, O; Miotto, A; Monnier, E; Nagy, E; Olivetto, C; Tisserant, S; Battistoni, G; Camin, D V; Cavalli, D; Costa, G; Cozzi, L; Resconi, S; Fedyakin, N N; Ferrari, A; Mandelli, L; Mazzanti, M; Perini, L; Sala, P R; Azuelos, Georges; Beaudoin, G; Depommier, P; León-Florián, E; Leroy, C; Roy, P; Serman, M; Augé, E; Chase, Robert L; Chollet, J C; de La Taille, C; Fayard, Louis; Fournier, D; Hrisoho, A T; Merkel, B; Noppe, J M; Parrour, G; Pétroff, P; Schaffer, A C; Seguin-Moreau, N; Serin, L; Tisserand, V; Vichou, I; Canton, B; David, J; Genat, J F; Imbault, D; Le Dortz, O; Savoy-Navarro, Aurore; Schwemling, P; Eek, L O; Lund-Jensen, B; Söderqvist, J; Lefebvre, M; Robertson, S; White, J

    1997-01-01

    The design and construction of a lead-liquid argon endcap calorimeter prototype using an accordion geometry and conceived as a sector of the inner wheel of the endcap calorimeter of the future ATLAS experiment at the LHC is described. The performance obtained using electron beam data is presented. The main results are an energy resolution with a sampling term below $11\\%/\\sqrt{E(\\rm GeV)}$ and a small local constant term, a good linearity of the response with the incident energy and a global constant term of 0.8\\% over an extended area in the rapidity range of $2.2 < \\eta <2.9$. These properties make the design suitable for the ATLAS electromagnetic endcap calorimeter.

  11. First tests of high resolution silicon pad detectors for the ALICE forward calorimeter

    International Nuclear Information System (INIS)

    To enrich the physics program of the ALICE experiment at CERN, a newly designed Electromagnetic Calorimeter is being proposed as a possible upgrade in the Forward pseudo rapidity region. The calorimeter will be installed at a distance of about 3.5 meters from the vertex and cover a region of 2.5 to 4.8 in pseudo rapidity. The detector will be a novel silicon-tungsten design, which will be used for the first time in any high-energy physics experiment. For full containment of photon energy up to 200 GeV it has been found that 24 radiation lengths (layers) of material is sufficient. For this purpose a sampling type calorimeter with tungsten (absorber) and silicon (active material) has been considered

  12. Technical and economic design of photovoltaic and battery energy storage system

    International Nuclear Information System (INIS)

    Highlights: • Design of grid connected photovoltaic system integrating battery energy storage system. • A model to manage the energy flows and assess the system profitability is presented. • The model evaluates the effective PV power rate and battery energy system capacity. • An application and multi-scenario analysis based on an Italian context is discussed. • Results show the system technical feasibility and an energy cost save of 52 €/MW h. - Abstract: In the last years, the technological development and the increasing market competitiveness of renewable energy systems, like solar and wind energy power plants, create favorable conditions to the switch of the electricity generation from large centralized facilities to small decentralized energy systems. The distributed electricity generation is a suitable option for a sustainable development thanks to the environmental impact reduction, the load management benefits and the opportunity to provide electricity to remote areas. Despite the current cut off of the national supporting policies to the renewables, the photovoltaic (PV) systems still find profitable conditions for the grid connected users when the produced energy is self-consumed. Due to the intermittent and random nature of the solar source, PV plants require the adoption of an energy storage system to compensate fluctuations and to meet the energy demand during the night hours. This paper presents a technical and economic model for the design of a grid connected PV plant with battery energy storage (BES) system, in which the electricity demand is satisfied through the PV–BES system and the national grid, as the backup source. The aim is to present the PV–BES system design and management strategy and to discuss the analytical model to determine the PV system rated power and the BES system capacity able to minimize the Levelized Cost of the Electricity (LCOE). The proposed model considers the hourly energy demand profile for a reference

  13. Visualizing and Understanding Atlas Calorimeters with Atlantis

    International Nuclear Information System (INIS)

    We describe tools that have been developed for the visualization and understanding of the hadronic and electromagnetic calorimeters of the Atlas experiment with the event visualization program Atlantis. The event data is extracted into XML format by dedicated algorithms running within the Atlas Software framework Athena, and read into Atlantis directly from physical data files or via a server/client-setup. For the Atlas Calorimeters commissioning, code was developed to create XML-data with detailed calorimeter information, like the electronic pulse shapes, calibration factors and cell identifiers. All this information is displayed in Atlantis through tools developed for this purpose. With these new features, the user has access to the reconstructed and raw data in the same place, and can check for example the consistency of the reconstruction. It allows easy identification of problematic calorimeter cells, e.g. high noise or dead cells, and also allows one to compare digital data from calorimeter and trigger channels, and was used during the Atlas detector commissioning in 2008 and 2009.

  14. LHCb Calorimeter modules arrive at CERN

    CERN Multimedia

    2002-01-01

    Two of the three components of the LHCb Calorimeter system have started to arrive from Russia. Members of the LHCb Calorimeter group with the ECAL and HCAL modules that have just arrived at CERN. The first two of the 56 Hadron Calorimeter (HCAL) modules and 1200 of the 3300 modules of the Electromagnetic Calorimeter (ECAL) have reached CERN from Russia. The third part of the system, the Preshower detector, is still being prepared in Russia. The calorimeter system identifies and triggers on high-energy particles, namely electrons, hadrons and photons by measuring their positions and energies. The HCAL is going to be a pure trigger device. The ECAL will also be used in the triggering, but in addition it will reconstruct neutral pions and photons from B meson decays. One of the major aims of the LHCb experiment is to study CP violation through B meson decays including Bs mesons with high statistics in different decay modes. CP violation (violation of charge and parity) is necessary to explain why the Universe...

  15. Skiroc : a Front-end Chip to Read Out the Imaging Silicon-Tungsten Calorimeter for ILC

    OpenAIRE

    Bouchel, M.; El Berni, M.; Fleury, J.; De La Taille, C.; Martin-Chassard, G.; Raux, L.; Wicek, F.; Bohner, G; Gay, Pascal; Lecoq, J.; Manen, S.; Royer, L.

    2007-01-01

    CALICE Collaboration EUDET Collaboration This abstract describes the new front end ASIC designed for the silicon tungsten electromagnetic calorimeter called SKIROC. This new chip embeds the main features required for the ILC final detector. Integration and low-power consumption of the read-out ASIC for the International Linear Collider (ILC) 82-million-channel W-Si calorimeter must reach an unprecedented level as it will be embedded inside the detector. Uniformity and dynamic range perform...

  16. Development and testing the prototype of an electromagnetic calorimeter, based on a lead tungstate crystals for the PHENIX experiment

    International Nuclear Information System (INIS)

    Electromagnetic calorimeter MPC project is a part of upgrade program of experiment PHENIX at the Relativistic Hadron-Ion Collider at BNL. MPC consists of two modules of approximately 200 channels each and located in the region of forward rapidities. This paper contains technical requirements for the project and results of MPC prototype beam tests

  17. Telemetry system for monitoring the ECG for patients with high cardiovascular risk. Main design requirements and technical solutions

    International Nuclear Information System (INIS)

    In this paper the main design requirements concerning the setting up of a telemetry ECG monitoring system are presented. The design's most important technical solutions as well as some details are also discussed. This system is intended to provide skilled medical assistance during the cardiac rehabilitation of both asymptomatic and high risk coronary patients

  18. Performance of the CMS Electromagnetic Calorimeter in pp collisions

    CERN Document Server

    Argiro, Stefano

    2010-01-01

    The CMS Electromagnetic Calorimeter (ECAL) is a high resolution, finely grained instrument devised to measure photons and electrons at LHC. Built of lead tungstate crystals, it will play a crucial role in the search for new physics as well as in precision measurements in the standard model. Thanks to this detector, the CMS collaboration was able to reconstruct di-photon states within minutes from the first LHC collisions. We will report on the commissioning and performance of the detector with 2009 and 2010 collision data, providing details about its calibration and synchronization, showing how well the challenging design goals were met.

  19. The CMS hadron calorimeter detector control system upgrade

    International Nuclear Information System (INIS)

    The detector control system of the CMS hadron calorimeter provides the 40.0788 MHz LHC clock to the front end electronics and supplies synchronization signals and I2C communication. Pedestals and diagnostic bits are controlled, and temperatures and voltages are read out. SIPM temperatures are actively stabilized by temperature readback and generation of correction voltages to drive the Peltier regulation system. Overall control and interfacing to databases and experimental DAQ software is provided by the software CCM Server. We report on design and development status, and implementation schedule of this system

  20. Performance of prototypes for the ALICE electromagnetic calorimeter

    International Nuclear Information System (INIS)

    The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A 4x4 array of final design modules showed an energy resolution of about 11%/√(E(GeV))+1.7% with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5mm+5.3mm/√(E(GeV)). For an electron identification efficiency of 90% a hadron rejection factor of >600 was obtained.