WorldWideScience

Sample records for calibration du calorimetre

  1. Calibration models for high enthalpy calorimetric probes.

    Science.gov (United States)

    Kannel, A

    1978-07-01

    The accuracy of gas-aspirated liquid-cooled calorimetric probes used for measuring the enthalpy of high-temperature gas streams is studied. The error in the differential temperature measurements caused by internal and external heat transfer interactions is considered and quantified by mathematical models. The analysis suggests calibration methods for the evaluation of dimensionless heat transfer parameters in the models, which then can give a more accurate value for the enthalpy of the sample. Calibration models for four types of calorimeters are applied to results from the literature and from our own experiments: a circular slit calorimeter developed by the author, single-cooling jacket probe, double-cooling jacket probe, and split-flow cooling jacket probe. The results show that the models are useful for describing and correcting the temperature measurements.

  2. Calibration by precise charge injection of a sub-detector of CMS; Calibration par injection de charge du calorimetre electromagnetique de CMS

    Energy Technology Data Exchange (ETDEWEB)

    Yong-Wook Baek

    2001-01-26

    This thesis was carried out within the framework of the international collaboration which has the responsibility of the experience CMS (Compact Muon Solenoid) on LHC, at CERN. The physics of the fundamental particles which will be explored by this experiment is described within the standard model. The configuration of sub-detector of CMS is briefly described, with a particular weight on the read-out chain of the electromagnetic calorimeter. The work carried out to calibrate this chain by a precise charge injection at the input of preamplifiers is described. The 4 integrated circuits CTRL, TPLS, DAC, and injector which will constitute the components of this chain of calibration are described. The circuit of injection, which is the main circuit in this project, was imagined and developed at the laboratory in DMILL technology. This injector generates a signal which has a form identical to the signal of the detector. The measurements on the linearity of the injectors are presented. In order to know its behavior under real conditions (flow of neutrons {approx} 2 x 10{sup 13} neutrons/cm{sup 2}/10 years) where this circuit is installed in detector CMS, we submitted the prototypes of injector to irradiation and the results are summarized. The research and development on this circuit produced an integrated circuit hardened to irradiations, whose variation of slope is lower than 0.25% for an integrated of 2 x 10{sup 13} neutrons/cm{sup 2} and indestructible under 10{sup 15} neutrons/cm{sup 2}. This circuit has satisfactory qualities to be assembled on the electronic card which will treat the data of calorimeter ECAL of CMS. (author)

  3. Calibration of the Atlas electromagnetic calorimeter. Search for the Higgs boson in its invisible decays; Etalonnage du calorimetre electromagnetique d'ATLAS. Recherche du boson de Higgs dans ses desintegrations invisibles

    Energy Technology Data Exchange (ETDEWEB)

    Neukermans, L

    2002-05-01

    The most promising channels for an intermediate mass Higgs boson discovery at LHC are leptonic and photonic decays. Therefore, a good uniformity of response of the electromagnetic calorimeter is required to reach the 0.7% constant term needed. This thesis deals with the absolute calibration of this detector. An electrical description of the calibration system, the detector and its read-out chain has been made for a better comprehension of the signal pulse shapes. A method, using a convolution of the calibration waveforms, has been developed to predict physics response, leading to absolute calibration. The level of accuracy obtained allows to reach the 0.3% contribution to the constant term required. Test beam analysis of a prototype module showed the performance of the electromagnetic calorimeter in terms of local resolution and linearity. A uniformity study has been made, leading to a 0.8% dispersion on a {delta}{eta} x {delta}{phi} = 1.2 x 0.75 area. In a second part, the observability of an invisible Higgs boson produced via weak boson fusion at the LHC is presented. A level 1 trigger strategy for this purely jet and missing E{sub T} final states is discussed. A method to measure the level of background using physics events is presented. This analysis shows that an invisible branching ratio of 25% could be reached at 95% CL with only 30 fb{sup -1} for a Higgs boson mass of 120 GeV/c{sup 2}. (author)

  4. Testing and calibration through laser radiation and muon beams of the hadron calorimeter in ATLAS detector; Controle et etalonnage par lumiere laser et par faisceaux de muons du calorimetre hadronique a tuiles scintillantes d'ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Garde, V

    2003-10-15

    This study is dedicated to the calibration of the hadronic calorimeter (Tilecal) of the ATLAS detector. This detector will be installed on the LHC collider at CERN. The first data will be taken in 2007. This thesis is divided in two parts. The first part is dedicated to the study of the LASER system. A prototype of the final system was studied. It was shown that the stability and the linearity of this prototype are conform to the specification. Several studies were devoted to measurements which can be done on the Tilecal: The relative gain can be calculated and gives the stability of the Tilecal with a resolution of 0.35 %. The number of photoelectrons per charge unit has been calculated. The linearity was checked for a normal range of functioning and was corrected for the functioning at high charge. In both cases it was shown that the non-linearity was smaller than 0.5 %. The second study is devoted to muons beams in test beam periods. These results are used to find a calibration constant. Several problems which come from the difference of size cells are not totally solved. But the resolution of the calibration constant found by this method cannot exceed 2.3%. (author)

  5. Comparison of the Thermal Response of Two Calorimetric Cells Dedicated to Nuclear Heating Measurements during Calibration

    International Nuclear Information System (INIS)

    Brun, J.; Reynard, C.; De-Vita, C.; Carette, M.; Muraglia, M.; Lyoussi, A.; Fourmentel, D.; Guimbal, P.; Villard, J-F.

    2013-06-01

    Nuclear heating is a key parameter which contributes to the thermal design and the quality of in-pile experiments performed in Material Testing Reactors (MTRs) for the study of nuclear materials and fuels under irradiation. Nuclear heating is typically measured in MTRs by radiometric calorimeters. However this kind of sensor has to be suited and improved in perspective of the new experimental conditions inside the channels of Jules Horowitz Reactor (JHR). In this paper, we study the responses of two non adiabatic differential calorimeter cells having the same geometric design, but different dimensions. These experimental works are carried out during a preliminary out-of-pile calibration operating procedure of these sensors which consists in simulating the sample heating by Joule effect. The influence of the imposed electrical power and of the forced cooling flow is determined on the sensor calibration curves. A more sensitive sensor leads to a quadratic calibration curve. This behavior difference of the two calorimetric configurations is explained by means of temperature and heat flux measurements performed with a new instrumented jacket. (authors)

  6. Calibration of the electromagnetic calorimeter of the Atlas detector: reconstruction of events with non-pointing photons in the frame of a GMSB supersymmetric model; Etalonnage du calorimetre electromagnetique du detecteur Atlas: reconstruction des evenements avec des photons non pointants das le cadre d'un modele supersymetrique GMSB

    Energy Technology Data Exchange (ETDEWEB)

    Prieur, D

    2005-04-15

    The analysis of test-beam data is focused on the calibration of the ATLAS electromagnetic calorimeter. An electrical model has been developed to predict the shape of the physics pulse out of the calibration signal in order to produce optimal filtering coefficients. They are used to compute energy while minimizing electronic noise and getting rid of any possible time shift. Using these coefficients, the uniformity response is 0.6%, in agreement with the 0.7% global constant term required for the whole calorimeter. The study of non pointing photon is driven by the detection of long lived neutralinos predicted by GMSB SUSY models. A systematic study with a detailed simulation of the ATLAS detector was performed to determine the electromagnetic calorimeter angular resolution for such photons. Results were used to parametrized the detector response and to reconstruct SUSY events from this model. (author)

  7. Thermal power calibrations of the IPR-R1 TRIGA reactor by the calorimetric and the heat balance methods

    International Nuclear Information System (INIS)

    Mesquita, Amir Zacarias; Rezende, Hugo Cesar; Souza, Rose Mary Gomes do Prado

    2009-01-01

    Since the first nuclear reactor was built, a number of methodological variations have been evolved for the calibration of the reactor thermal power. Power monitoring of reactors is done by means of neutronic instruments, but its calibration is always done by thermal procedures. The purpose of this paper is to present the results of the thermal power calibration carried out on March 5th, 2009 in the IPR-R1 TRIGA reactor. It was used two procedures: the calorimetric and heat balance methods. The calorimetric procedure was done with the reactor operating at a constant power, with primary cooling system switched off. The rate of temperature rise of the water was recorded. The reactor power is calculate as a function of the temperature-rise rate and the system heat capacity constant. The heat balance procedure consists in the steady-state energy balance of the primary cooling loop of the reactor. For this balance, the inlet and outlet temperatures and the water flow in the primary cooling loop were measured. The heat transferred through the primary loop was added to the heat leakage from the reactor pool. The calorimetric method calibration presented a large uncertainty. The main source of error was the determination of the heat content of the system, due to a large uncertainty in the volume of the water in the system and a lack of homogenization of the water temperature. The heat balance calibration in the primary loop is the standard procedure for calibrating the power of the IPR-R1 TRIGA nuclear reactor. (author))

  8. New calibration methodology for calorimetric determination of isobaric thermal expansivity of liquids as a function of temperature and pressure

    Energy Technology Data Exchange (ETDEWEB)

    Navia, Paloma; Troncoso, Jacobo [Departamento de Fisica Aplicada, Facultad de Ciencias de Ourense, Campus As Lagoas, 32004 Ourense (Spain); Romani, Luis [Departamento de Fisica Aplicada, Facultad de Ciencias de Ourense, Campus As Lagoas, 32004 Ourense (Spain)], E-mail: romani@uvigo.es

    2008-11-15

    A new method for determining isobaric thermal expansivity of liquids as a function of temperature and pressure through calorimetric measurements against pressure is described. It is based on a previously reported measurement technique, but due to the different kind of calorimeter and experimental set up, a new calibration procedure was developed. Two isobaric thermal expansivity standards are needed; in this work, with a view on the quality of the available literature data, hexane and water are chosen. The measurements were carried out in the temperature and pressure intervals (278.15 to 348.15) K and (0.5 to 55) MPa for a set of liquids, and experimental values are compared with the available literature data in order to evaluate the precision of the experimental procedure. The analysis of the results reveals that the proposed methodology is highly accurate for isobaric thermal expansivity determination, and it allows obtaining a precise characterisation of the temperature and pressure dependence of this thermodynamic coefficient.

  9. New calibration methodology for calorimetric determination of isobaric thermal expansivity of liquids as a function of temperature and pressure

    International Nuclear Information System (INIS)

    Navia, Paloma; Troncoso, Jacobo; Romani, Luis

    2008-01-01

    A new method for determining isobaric thermal expansivity of liquids as a function of temperature and pressure through calorimetric measurements against pressure is described. It is based on a previously reported measurement technique, but due to the different kind of calorimeter and experimental set up, a new calibration procedure was developed. Two isobaric thermal expansivity standards are needed; in this work, with a view on the quality of the available literature data, hexane and water are chosen. The measurements were carried out in the temperature and pressure intervals (278.15 to 348.15) K and (0.5 to 55) MPa for a set of liquids, and experimental values are compared with the available literature data in order to evaluate the precision of the experimental procedure. The analysis of the results reveals that the proposed methodology is highly accurate for isobaric thermal expansivity determination, and it allows obtaining a precise characterisation of the temperature and pressure dependence of this thermodynamic coefficient

  10. Search for the supersymmetric partner of the top quark in the channel stop anti-stop {yields} e{sup {+-}} {mu}{sup {+-}} sneutrino anti-sneutrino b anti-b in D0 experiment at the Tevatron. Calibration of the D0 electromagnetic calorimeter; Recherche du partenaire supersymetrique du quark top dans le canal stop anti-stop {yields} e{sup {+-}} {mu}{sup {+-}} sneutrino anti-sneutrino b anti-b au sein de l'experience D0 aupres du TeVatron. Calibration du calorimetre electromagnetique de D0

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, A

    2006-10-15

    Symmetry is one of the most natural extensions of the standard model. At low energy it may consist in the Minimal Supersymmetric Standard Model which is the framework chosen to perform the search of the stop with 350 pb{sup -1} of data collected by D0 during the run-IIa period of the Tevatron. We selected the events with an electron, a muon, missing transverse energy and non-isolated tracks, signature for the stop decay in 3 particles (stop {yields} bl sneutrino). Since no significant excess of signal is seen, the results are interpreted in terms of limit on the stop production cross-sections, in such a way that we extend the existing exclusion region in the parameter space (m(stop), m(sneutrino)) up to stop masses of 168 (140) GeV for sneutrino masses of 50 (94) GeV. Finally, because of the crucial role of the electromagnetic calorimeter, a fine calibration was performed using Z {yields} e{sup +}e{sup -} events, which improved significantly the energy resolution. (author)

  11. Search for the supersymmetric partner of the top quark in the channel stop anti-stop {yields} e{sup {+-}} {mu}{sup {+-}} sneutrino anti-sneutrino b anti-b in D0 experiment at the Tevatron. Calibration of the D0 electromagnetic calorimeter; Recherche du partenaire supersymetrique du quark top dans le canal stop anti-stop {yields} e{sup {+-}} {mu}{sup {+-}} sneutrino anti-sneutrino b anti-b au sein de l'experience D0 aupres du TeVatron. Calibration du calorimetre electromagnetique de D0

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, A

    2006-10-15

    Symmetry is one of the most natural extensions of the standard model. At low energy it may consist in the Minimal Supersymmetric Standard Model which is the framework chosen to perform the search of the stop with 350 pb{sup -1} of data collected by D0 during the run-IIa period of the Tevatron. We selected the events with an electron, a muon, missing transverse energy and non-isolated tracks, signature for the stop decay in 3 particles (stop {yields} bl sneutrino). Since no significant excess of signal is seen, the results are interpreted in terms of limit on the stop production cross-sections, in such a way that we extend the existing exclusion region in the parameter space (m(stop), m(sneutrino)) up to stop masses of 168 (140) GeV for sneutrino masses of 50 (94) GeV. Finally, because of the crucial role of the electromagnetic calorimeter, a fine calibration was performed using Z {yields} e{sup +}e{sup -} events, which improved significantly the energy resolution. (author)

  12. The Calvet calorimetric dosimeter

    International Nuclear Information System (INIS)

    Puig, J.R.; Romano, F.

    1965-01-01

    This report describes a dosimeter based on the conduction calorimetry principle, and designed to operate in swimming-pool type nuclear reactors. The properties of the apparatus are as follows: 1 - the measurement is independent of the specific heat of the calorimetric elements; 2 - each calorimetric element is fitted with an electrical calibration; 3 - the apparatus is made up of two independent calorimetric elements; 4 - the nature of the calorimetric elements makes it possible to analyse the radiation received; 5 - the measurable intensities of the absorbed radiation vary from 4 to 4000 M/rads per hour; 6 - the sensitive part of the apparatus is fitted inside a cylinder 5 cm high and 2 cm in diameter. One pre-production unit made up of graphite and beryllium cores has been tried out in the reactor Siloe with radiation intensities of about 1 to 2 watts per gram. It absorbed an accumulated dose of 1.2*1O 12 rads without any weaknesses appearing. (authors) [fr

  13. Calibration of the electromagnetic barrel calorimeter. Identification of the tau leptons and search for a Higgs boson in the channel qqH {yields} qq {tau}{tau} in the Atlas experiment at LHC; Etalonnage du calorimetre electromagnetique tonneau. Identification des leptons taus et recherche d'un boson de Higgs dans le canal qqH {yields} qq {tau}{tau} dans l'experience ATLAS au LHC

    Energy Technology Data Exchange (ETDEWEB)

    Tarrade, F

    2006-09-15

    The Standard Model is the theory which describes the fundamental interactions most accurately. However, the Higgs mechanism and its associated boson have not yet been discovered. The ATLAS electromagnetic calorimeter will play an important role in its discovery if it exists. In the first part of this work, a final mapping of all barrel electromagnetic calorimeter cells, and in particular the problematic ones, was made. Then, the code for the calorimeter calibration was migrated into the ATLAS software environment (ATHENA), where it was tested and validated with the 2004 test beam data. In this code, the optimal filtering coefficients, which enable to reconstruct the energy deposited in the calorimeter while minimizing the electronic and pile-up noises, are calculated. For this, a model was developed to predict the physics signal waveform from the calibration waveform. In a third part, two algorithms for reconstructing and identifying {tau} leptons in their hadronic decay mode were studied and compared. Finally in a fourth part, one amongst the most important Standard Model Higgs production and decay channels was investigated, namely the weak boson fusion production followed by the Higgs decay into a tau lepton pair, for a low mass Higgs (115 < m{sub Higgs} < 145 GeV/c{sup 2}). This study was performed for 30 fb{sup -1} of integrated luminosity using fast and fully simulated data. A study of the dominant background Z + n jets (n {<=} 5) was also performed. (author)

  14. Top quark studies with Atlas at the LHC. Electromagnetic calorimeter commissioning; Etude du quark top avec Atlas au LHC. Mise en route du calorimetre electromagnetique

    Energy Technology Data Exchange (ETDEWEB)

    Resende Vaz de Melo Xavier, B

    2007-05-15

    The first proton-proton collisions in the Large Hadron Collider at CERN will take place on 2007. It aims at understanding the origins of mass. and it will also look for new physics. The ATLAS experiment will exploit all those physics potentialities. using a multilayer generalist detector. Quark top studies will be an important step in ATLAS physics program: its properties may reveal hints of new phenomena. One way to look for new physics is through quark top and W boson polarizations. which are studied here. This detailed simulation study has confirmed previous fast simulation results including extensive systematics estimation. ATLAS should thus yield a precision of a few percents with 10 fb{sup -1} of data. that is a year of LHC working. This precision is sufficient to select among several new physics models. Among ATLAS subsystems, the electromagnetic calorimeter plays a crucial role in the characterisation of electrons and photons. which are used in particular for the Higgs boson search. This document deals with the calorimeter commissioning as the time of the first collisions approaches. The detector itself and its electronics will be described, as well as its installation and calibration. Cosmic muons observation will then be presented. as the first overall test of the reading and reconstruction electronics chain in actual working conditions. (author)

  15. Qualification of an out-of-pile Thermohydraulic test Bench (BETHY) developed to calibrate calorimetric cells under specific JHR experimental conditions

    International Nuclear Information System (INIS)

    De Vita, C.; Brun, J.; Carette, M.; Reynard-Carette, C.; Lyoussi, A.; Fourmentel, D.; Villard, J.F.; Guimbal, P.; Malo, J.Y.

    2013-06-01

    Online in-pile measurement methods are crucial during irradiations in material testing reactors to better understand the behavior of materials under accelerated ageing conditions and of nuclear fuels under high irradiation levels. Thus, the construction of a new Material Testing Reactor such as the Jules Horowitz Reactor (JHR) leads to new research and development programs devoted to innovative instrumentation and measurement methods. The presented works are performed in the framework of the IN-CORE program, 'Instrumentation for Nuclear radiations and Calorimetry Online in Reactor', between CEA and Aix-Marseille University. The program aim is to develop experimental devices and test bench to quantify more precisely the nuclear heating parameter in the JHR experimental channels. This in-pile parameter is usually measured by means of calorimeter or gamma thermometer. This paper focuses on a new out-of-pile test bench called BETHY. This bench was developed to study the response of a differential calorimeter during its preliminary calibration step according to specific thermal and hydraulic conditions occurring inside one type of JHR core channel. The first section of this paper is dedicated to a detailed description of the bench. The second part presents the study of the thermal characteristics established in the bench for two main thermal running modes. The last one concerns the calibration curve of the reference cell of the differential calorimeter in the case of homogenous temperature. (authors)

  16. Study of the optical monitoring system of the scintillating crystal involved in the electromagnetic calorimeter of CMS experiment; Etude du systeme de suivi optique des cristaux scintillants du calorimetre electromagnetique de l`experience CMS

    Energy Technology Data Exchange (ETDEWEB)

    Geleoc, M

    1998-09-04

    The prospect of the experimental discovery of the Higgs boson is one of the motivations to build the large hadron collider (LHC). Proton beams will collide and the emitted particles will be detected by ATLAS and CMS equipment. In each detector the electromagnetic calorimeter will allow the characterisation of the 2 photons coming from one of the disintegration channels of the Higgs boson. CMS collaboration has chosen an homogeneous calorimeter fitted with PbWO{sub 4} crystals. Each crystal with its photodetector and its electronic device forms one detection channel. The resolution of the detection channels should not deteriorate all along the operating time. The optical monitoring system of the crystals logs then controls the response of each detection channel in order to allow an accurate calibration of the calorimeter. The optical properties, the resistance to irradiation of PbWO{sub 4} crystals and the modelling of light collection are investigated in this work. The description of the different components of the optical monitoring system highlights the technical difficulties we had to challenge. An experimental testing bench has been set up to study the coupling between the scintillation signal and the signal that feeds the monitoring system, this coupling has been studied under irradiation in the conditions of CMS operating. (A.C.) 94 refs.

  17. Calorimetric dosimetry of reactor radiation

    International Nuclear Information System (INIS)

    Radak, B.; Markovic, V.; Draganic, I.

    1961-01-01

    Calorimetric dosimetry of reactor radiation is relatively new reactor dosimetry method and the number of relevant papers is rather small. Some difficulties in applying standard methods (chemical dosemeters, ionization chambers) exist because of the complexity of radiation. In general application of calorimetric dosemeters for measuring absorbed doses is most precise. In addition to adequate choice of calorimetric bodies there is a possibility of determining the yields of each component of the radiation mixture in the total absorbed dose. This paper contains a short review of the basic calorimetry methods and some results of measurements at the RA reactor in Vinca performed by isothermal calorimeter [sr

  18. Calibration

    International Nuclear Information System (INIS)

    Greacen, E.L.; Correll, R.L.; Cunningham, R.B.; Johns, G.G.; Nicolls, K.D.

    1981-01-01

    Procedures common to different methods of calibration of neutron moisture meters are outlined and laboratory and field calibration methods compared. Gross errors which arise from faulty calibration techniques are described. The count rate can be affected by the dry bulk density of the soil, the volumetric content of constitutional hydrogen and other chemical components of the soil and soil solution. Calibration is further complicated by the fact that the neutron meter responds more strongly to the soil properties close to the detector and source. The differences in slope of calibration curves for different soils can be as much as 40%

  19. Calage thermodynamique du point mort haut des moteurs à piston Thermodynamic Calibration of Top Dead Center in Piston Engines

    Directory of Open Access Journals (Sweden)

    Pinchon P.

    2006-11-01

    Full Text Available Lorsqu'on utilise un système d'acquisition rapide de données sur moteur, il se pose souvent le problème d'associer des grandeurs calculées, comme le volume de la chambre de combustion, à des grandeurs mesurées comme la pression dans le cylindre. II est alors indispensable de synchroniser avec une grande précision absolue ces deux grandeurs en repérant avec soin au moins un point de référence de la cinématique bielle-manivelle. Dans la méthode développée ici on a choisi de déterminer la position angulaire du vilebrequin correspondant au Point Mort Haut (PMH grâce à l'exploitation du signal de pression-cylindre acquis en compression-détente sans combustion, le moteur étant entraîné en rotation. Le principe du calage consiste à calculer l'écart existant entre le PMH et l'angle de la pression maximale qui est aisément repérable. Basée sur des considérations thermodynamiques théoriques, cette méthode de calage a été testée avec succès au cours d'essais effectués sur divers moteurs dont on a fait varier en particulier le rapport volumétrique, le remplissage et les pertes à la segmentation. La précision de la méthode est de l'ordre de 1/10e de degré de rotation vilebrequin. When a fast data-acquisition system is used for an engine, the problem often arises of associating both calculated data, such as combustion chamber volume, and measured data, such as pressure inside the cylinder. It then becomes indispensable to synchronize these two data with great absolute accuracy by carefully determining at least a reference point in the kinematics of the connecting-rod/crank shaft assembly. In the method developed here, we have chosen to determine the angular position of the crankshaft corresponding to top dead center (TDC by making use of the cylinder-pressure signal recorded during compression/expansion without combustion for motored engine. The calibration principle consists in calculating the shift between TDC and the

  20. Calorimetric sensors for energy deposition measurements

    International Nuclear Information System (INIS)

    Langenbrunner, J.; Cooper, R.; Morgan, G.

    1998-01-01

    A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-kΩ thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl

  1. A calorimetric method to determine water activity.

    Science.gov (United States)

    Björklund, Sebastian; Wadsö, Lars

    2011-11-01

    A calorimetric method to determine water activity covering the full range of the water activity scale is presented. A dry stream of nitrogen gas is passed either over the solution whose activity should be determined or left dry before it is saturated by bubbling through water in an isothermal calorimeter. The unknown activity is in principle determined by comparing the thermal power of vaporization related to the gas stream with unknown activity to that with zero activity. Except for three minor corrections (for pressure drop, non-perfect humidification, and evaporative cooling) the unknown water activity is calculated solely based on the water activity end-points zero and unity. Thus, there is no need for calibration with references with known water activities. The method has been evaluated at 30 °C by measuring the water activity of seven aqueous sodium chloride solutions ranging from 0.1 mol kg(-1) to 3 mol kg(-1) and seven saturated aqueous salt solutions (LiCl, MgCl(2), NaBr, NaCl, KCl, KNO(3), and K(2)SO(4)) with known water activities. The performance of the method was adequate over the complete water activity scale. At high water activities the performance was excellent, which is encouraging as many other methods used for water activity determination have limited performance at high water activities. © 2011 American Institute of Physics

  2. Calorimetric cryodetectors for heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Egelhof, P; Henning, W; Kienlin, A v; Meier, J; Truebenbacher, V [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany, F.R.) Mainz Univ. (Germany, F.R.). Inst. fuer Physik; Azgui, F [CDTN, Algiers (Algeria); Shepard, K [Argonne National Lab., IL (USA)

    1990-01-01

    Status and first test results are reported for a project to develop calorimetric cryodetectors for heavy ions. The special conditions for the detection of energetic heavy ions are discussed. Presently the investigations are focussed on semiconductor bolometers and aluminium-strip superconducting phase-transition thermometers that are cooled with liquid {sup 4}He and operate in the temperature range 1.3-4.2 K. For a germanium bolometer the temperature dependence of the resistance, voltage-current curves, the time response to heating by voltage pulses and the response to ionizing {alpha}-radiation are reported. First tests on phase transition thermometers using thin aluminum strips yield a transition width of {Delta}T=8.6 mK at T{sub c}=1.467 K. (orig.).

  3. Calorimetric study of bromoacetophenone isomers

    International Nuclear Information System (INIS)

    Amaral, Luísa M.P.F.; Ribeiro da Silva, Manuel A.V.

    2014-01-01

    Highlights: • A calorimetric study of bromoacetophenone isomers was performed. • Enthalpies of formation were derived by rotating-bomb combustion calorimetry. • Enthalpies of phase transition were determined by Calvet microcalorimetry. • Cox scheme was applied for the estimation of Δ f H m o (g) for the compounds. • The values of Δ f H m o (g) were compared with literature values for similar compounds. - Abstract: The standard (p o = 0.1 MPa) molar enthalpies of formation of 2-, 2′-, 3′- and 4′-bromoacetophenones were derived from the standard molar energies of combustion in oxygen, to yield CO 2 (g) and HBr·600H 2 O (l) at T = 298.15 K, measured by rotating bomb combustion calorimetry. The standard molar enthalpies associated with phase transitions of the isomers studied at T = 298.15 K, were obtained by high temperature Calvet microcalorimetry. The standard (p o = 0.1 MPa) molar enthalpies of formation of all the bromoacetophenone isomers in the gaseous phase at T = 298.15 K were derived from the experimental results. The gas-phase enthalpies of formation were also estimated by the empirical scheme developed by Cox and the values obtained were compared with the experimental ones. The results are interpreted in terms of the energetic increments for the introduction of the substituents in the benzene ring

  4. Etude de la diagraphie neutron du granite de Beauvoir. Effet neutron des altérations et de la matrice du granite. Calibration granite. Porosité totale à l'eau et porosité neutron Analysis of the Beauvoir Granite Neutron Log. Neutron Effect of Alterations and of the Granite Matrix. Granite Calibration. Total Water Porosity and Neutron Porosity

    Directory of Open Access Journals (Sweden)

    Galle C.

    2006-11-01

    Full Text Available Cet article rend compte des travaux effectués sur la porosité du granite de Beauvoir (Sondage GPF 1 d'Echassières, Massif Central français. L'objectif de notre étude est de pouvoir obtenir des valeurs représentatives de la saturation en eau (porosité totale à l'eau n du granite de Beauvoir à partir des mesures de porosité neutron PorositéN (diagraphie neutron BRGM sans avoir recours aux mesures sur carottes. Notre démarche est expérimentale et nous avons tenté d'approfondir certains problèmes liés à l'utilisation de la diagraphie neutron dans une roche granitique. Deux facteurs principaux conditionnent la réponse neutron : la concentration en hydrogène de la formation (eau libre et eau de constitution de certains minéraux et la présence d'éléments absorbeurs à forte section de capture comme le gadolinium, le cadmium, le bore, . . . et dans le cas du granite de Beauvoir, le lithium. A partir des mesures de porosité totale à l'eau n sur carottes, des essais de pertes au feu sur poudre qui nous permettent de déterminer la porosité neutron liée à l'eau de constitution PorositéN(OH- et des analyses chimiques avec lesquelles nous évaluons la porosité neutron thermique PorositéN(ox (Programme SNUPAR, Schlumberger liée à la capture neutronique, nous reconstituons la porosité neutron totale PorositéNR du granite de Beauvoir. Pour 7 échantillons caractéristiques du granite de Beauvoir, nous réalisons grâce à ces résultats une nouvelle calibration du taux de comptage neutron initial corrigé du gradient thermique et de l'effet de trou. Grâce à cette opération, il est possible de déterminer, pour les échantillons traités, la porosité neutron du granite avec une calibration granite (PorositéNg et non calcaire (PorositéNc. La connaissance de l'effet neutron de la matrice nous permet enfin d'évaluer la teneur en eau du granite (porosité totale à l'eau et de comparer celle-ci avec la porosité mesurée sur

  5. Radioactivity measurements of metallic 192Ir sources by calorimetric methods

    International Nuclear Information System (INIS)

    Genka, Tsuguo; Iwamoto, Seikichi; Takeuchi, Norio

    1992-01-01

    The necessity of establishing the traceability of dose measurement in brachytherapy 192 Ir sources is realized by physicians and researchers in the medical field. Standard sources of various shapes such as open-quotes hairpin,close quotes open-quotes single pin,close quotes open-quotes thin wire,close quotes and open-quotes seedclose quotes for calibrating ionization chambers in hospitals are being demanded. Nominal activities of not only these source products but also the standard sources have been so far specified by open-quotes apparentclose quotes values. Determination of open-quotes absoluteclose quotes activity by an established means such as 4pi-beta-gamma coincidence counting is not practical because quantitative dissolution of metallic iridium is very difficult. We tried to determine the open-quotes absoluteclose quotes activity by a calorimetric method in a fully nondestructive way

  6. Comparison and qualification of FFTF calorimetric methods

    International Nuclear Information System (INIS)

    McCall, T.B.; Nutt, W.T.; Zimmerman, B.D.

    1981-01-01

    The Fast Flux Test Facility achieved full power operation on December 21, 1981. During the power ascent, the reactor thermal power (calorimetric) was computed by three methods as follows: the plant main data handling computer, Plant Data System (PDS); a second computer, the Experimenter's Data System (EDS); and a manual method requiring human operator activities and a programmable calculator. It is the purpose of this paper to explain the rationale for employing the three methods, describe how each works in a schematic fashion, compare the results, and demonstrate that all methods have met stringent goals based on a statistical analysis of the results

  7. Optimization through neuron network of the potentiality of Higgs discovery in the CMS detector via H {yields} ZZ{sup *} {yields} 4e{sup {+-}}, and study of the triggering primitives of the electromagnetic calorimeter; Optimisation par reseaux de neurones du potentiel de decouverte du boson de Higgs dans le canal H {yields} ZZ{sup *} {yields} 4e{sup {+-}} sur le detecteur CMS, et etude des primitives de declenchement du calorimetre electromagnetique

    Energy Technology Data Exchange (ETDEWEB)

    Bimbot, St

    2006-10-15

    The first chapter presents the theoretical background on which the Higgs mechanism is based within the framework of the standard model. The second chapter reviews the past and present attempts aiming at the discovery of the Higgs boson. The specific features of the Large Hadron Collider (LHC) and of one of its detector: the CMS (Compact Muon Solenoid) detector are given in the third chapter. The author details the track detector and the ECAL electronic calorimeter that are key components of CMS in the detection of the Higgs boson via the following decay channel: H {yields} ZZ{sup *} {yields} 2e{sup +}2e{sup -} (where Z and Z{sup *} represents the Z{sup O} boson in a real state and in a virtual state respectively). The chapters 4 and 5 are dedicated to the calibration of the ECAL calorimeter via the use of an electron beam and to the triggering system. The data analysis that will lead to the reconstruction of the events detected by CMS is presented in the chapter 6. The last chapter is devoted to the optimization of the extraction of the Higgs boson signal from an abundant background noise. (A.C.)

  8. Calorimetric method of ac loss measurement in a rotating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ghoshal, P. K. [Oxford Instruments NanoScience, Abingdon, Oxfordshire OX13 5QX (United Kingdom); Coombs, T. A.; Campbell, A. M. [Department of Engineering, Electrical Engineering, University of Cambridge, Cambridge CB3 0FA (United Kingdom)

    2010-07-15

    A method is described for calorimetric ac-loss measurements of high-T{sub c} superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  9. Calorimetric Measuring Systems for Characterizing High Frequency Power Losses in Power Electronic Components and Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Pedersen, John Kim; Ritchie, Andrew Ewen

    2002-01-01

    High frequency power losses in power electronic components and systems are very difficult to measure. The same applies to the efficiency of high-efficiency systems and components. An important method to measure losses with high accuracy is the calorimetric measuring systems. This paper describes...... to calibrate such systems are proposed and different applications of the system are given. Two practical examples end the description of the research. It is concluded that such systems have a relative long time-constant but they are accurate and useful for precise power loss measurement....

  10. Electrical and calorimetric measurements and related software

    CERN Document Server

    Catalan-Lasheras, N; Koratzinos, M; Rijllart, A; Siemko, A; Strait, J; Tavian, L; Wolf, R

    2009-01-01

    During the incident of sector 3-4 on September 19th, the temperature of a number of magnets increased over the expected values prior to the circuit failure. A review of the data logged during powering tests on all circuits indicated potential resistive splices in sectors 1-2 and 6-7. Calorimetric and electrical measurements confirmed a high resistance in magnet B16. R1 and B32R6. Systematic measurements have been performed in other cold sectors of the LHC during which the temperature increase and voltage across magnets were acquired at different currents. Cryogenic subsectors on which the temperature increase was abnormal were equipped with precise voltmeters to detect eventual resistive splices in the bus-bars. The findings of the measurement campaign will be shown as well as the plans to implement similar diagnostics as a routine check prior to powering the superconducting circuits of the LHC.

  11. AC loss measurement of superconducting dipole magnets by the calorimetric method

    International Nuclear Information System (INIS)

    Morita, Y.; Hara, K.; Higashi, N.; Kabe, A.

    1996-01-01

    AC losses of superconducting dipole magnets were measured by the calorimetric method. The magnets were model dipole magnets designed for the SSC. These were fabricated at KEK with 50-mm aperture and 1.3-m overall length. The magnet was set in a helium cryostat and cooled down to 1.8 K with 130 L of pressurized superfluid helium. Heat dissipated by the magnet during ramp cycles was measured by temperature rise of the superfluid helium. Heat leakage into the helium cryostat was 1.6 W and was subtracted from the measured heat to obtain AC loss of the magnet. An electrical measurement was carried out for calibration. Results of the two methods agreed within the experimental accuracy. The authors present the helium cryostat and measurement system in detail, and discuss the results of AC loss measurement

  12. The CMS electromagnetic calorimeter and the search for the Higgs boson in the decay channel H {yields} WW{sup *} {yields} 2e2{nu}; Le calorimetre electromagnetique de CMS et la recherche du boson de Higgs dans le canal de desintegration H {yields} WW{sup *} {yields} 2e2{nu}

    Energy Technology Data Exchange (ETDEWEB)

    Rovelli, I.Ch

    2006-01-15

    CMS is one of the four experiments that will take data at the LHC. Large part of my work was devoted to the development of electron reconstruction tools aimed at improving the Higgs boson discovery potential in the H {yields} WW{sup *} {yields} 2e2{nu} channel. A major role in the electron reconstruction is played by the electromagnetic calorimeter ECAL, an homogeneous calorimeter made of scintillating PbWO{sub 4} crystals. The first 3 chapters give an overview of LHC and CMS.In chapter 4 the analysis of the data collected during the 2003 electromagnetic calorimeter test beam is presented. First the problem of the intercalibration at the test beam is addressed. This is a major task, since the precision of the intercalibration directly affects the constant term of the energy resolution, for which the CMS goal is to reach a precision better than 0.5%. The good initial intercalibration, anyway, could be spoiled during the data taking by the effects of the radiation on the crystals, which can change the relative responses of the channels. A monitoring laser system is foreseen at CMS. The possibility to check the calibration stability and to correct the changes in the response with a precision within the required limits is demonstrated. Chapter five describes the electron reconstruction and identification in CMS. A crucial problem for the electron reconstruction is represented by the Bremsstrahlung emission in the tracker. A tracking procedure dealing with the Bremsstrahlung energy loss is discussed. Together with an improvement in the reconstruction efficiency, the procedure allows to identify electrons with a small fraction of radiated energy, which can be usefully exploited for the ECAL calibration. The developed algorithms are applied in chapter 6, which presents the study of the CMS discovery potential of the Higgs boson in the H {yields} WW{sup *} {yields} 2e2{nu} channel. This is the discovery channel in the range of masses between 2m{sub W} and 2m{sub Z}. Here

  13. Calorimetric dosimetry in neutron and charged particle beams

    International Nuclear Information System (INIS)

    McDonald, J.C.; Ma, I.C.; Laughlin, J.S.

    1978-01-01

    A portable tissue-equivalent (TE) calorimetric, constructed of A-150 plastic, has been employed for the measurement of absorbed dose in several neutron radiotherapy fields. Comparisons of spherical, cylindrical, and thimble shaped TE ionization chambers have been carried out using either air, or a flow of TE gas in the chamber

  14. Study of performances of the liquid krypton calorimeter of the NA48 experiment for measurement of Re({epsilon}'/{epsilon}); Etude des performances du calorimetre a krypton liquide de l'experience NA48 pour la mesure de Re({epsilon}'/{epsilon})

    Energy Technology Data Exchange (ETDEWEB)

    Ocariz, Jose [Lab. de l' Accelerateur Lineaire, Paris-11 Univ., 91 - Orsay (France)

    1999-04-19

    The purpose of the NA48 experiment is the study of direct violation of CP symmetry in the system of neutral kaons. The double ratio of neutral and charged two pion decays, violating and conserving CP should be measured with an ultimate accuracy of about 0.1%. In attain this objective one of the important ingredients is the liquid krypton calorimeter, which allows to identify the neutral modes with a very good accuracy. One should therefore ensure that the systematic effects are weak. The performances of this calorimeter, particularly in energy response, are studied with data acquired in 1997. These studies are mainly effected for the K{sub e3} semileptonic decays by comparing the energy reconstructed in the calorimeter with the momentum obtained by the magnetic spectrometer. These data allow to constrain significantly the energy resolution, the response non-linearity as well as the detector geometry and to optimize the calibration. The energy resolution achieved is better than 1% for energies above 25 GeV. This allows to reduce the background in the neutral mode at the level of 0.1%. The systematic uncertainties from calorimeter on the measurement of double ratio are estimated for the 1997 data at 0.1%. This value is clearly below the statistical error of 0.27% for these data.

  15. Study of performances of the liquid krypton calorimeter of the NA48 experiment for measurement of Re({epsilon}'/{epsilon}); Etude des performances du calorimetre a krypton liquide de l'experience NA48 pour la mesure de Re({epsilon}'/{epsilon})

    Energy Technology Data Exchange (ETDEWEB)

    Ocariz, Jose [Lab. de l' Accelerateur Lineaire, Paris-11 Univ., 91 - Orsay (France)

    1999-04-19

    The purpose of the NA48 experiment is the study of direct violation of CP symmetry in the system of neutral kaons. The double ratio of neutral and charged two pion decays, violating and conserving CP should be measured with an ultimate accuracy of about 0.1%. In attain this objective one of the important ingredients is the liquid krypton calorimeter, which allows to identify the neutral modes with a very good accuracy. One should therefore ensure that the systematic effects are weak. The performances of this calorimeter, particularly in energy response, are studied with data acquired in 1997. These studies are mainly effected for the K{sub e3} semileptonic decays by comparing the energy reconstructed in the calorimeter with the momentum obtained by the magnetic spectrometer. These data allow to constrain significantly the energy resolution, the response non-linearity as well as the detector geometry and to optimize the calibration. The energy resolution achieved is better than 1% for energies above 25 GeV. This allows to reduce the background in the neutral mode at the level of 0.1%. The systematic uncertainties from calorimeter on the measurement of double ratio are estimated for the 1997 data at 0.1%. This value is clearly below the statistical error of 0.27% for these data.

  16. Calorimetric measurement of strong γ emitting sources

    International Nuclear Information System (INIS)

    Brangier, B.; Herczeg, C.; Henry, R.

    1968-01-01

    This publication gives the principle and a description of an adiabatic calorimeter for measuring the real activity of strong gamma-emitting sources by absorbing the emitted energy in a mass of copper. Because of the difficulty of evaluating the amount self- absorption, we have built a calorimeter for measuring the self- absorption, and a description of it is given.The results of these three measurements are fairly satisfactory. The calibration and the actual measurements obtained are given with a few corrections made necessary by the design of the apparatus. The correlation of the various results is discussed. (author) [fr

  17. Transport and calorimetric properties of AISI 321 by pulse thermal diffusivity and calorimetric techniques

    International Nuclear Information System (INIS)

    Perovic, N.L.; Maglic, K.D.; Stanimirovic, A.M.; Vukovic, G.S.

    1995-01-01

    The study of the thermophysical properties of AISI 321 stainless steel was the last part of work within the IAEA-coordinated Research Programme for the Establishment of a Database of Thermophysical Properties of LW and HW Reactor Materials (IAEA CRP) effected at the Institute of Nuclear Sciences Vinca (NIV). The AISI 321 stainless steel belongs to the group of construction materials whose thermophysical and calorimetric properties have significance for the IAEA CRP. Because there have been few investigations of the thermal properties of this material, the CRP foresaw the need for new measurements, which are reported in this paper. Experimental research performed at NIV consisted of the investigation of thermal diffusivity, electric resistivity, and specific heat capacity of this austenitic stainless steel. The thermal diffusivity was measured by the laser pulse technique, and the elastic resistivity and specific heat capacity were determined by use of millisecond-resolution pulse calorimetry. All measurements were performed from ambient temperature to above 1000 o C, within which temperature range the material maintains its structure and stable thermophysical properties. Values for the thermal conductivity were computed from data on the thermal diffusivity, specific heat capacity, and the room-temperature density. (author)

  18. An in-beam test study of the response of calorimeters in the ATLAS Experiment of LHC to charged pions of 3 to 350 GeV energy range; Etude en faisceau-test de la reponse des calorimetres de l'Experience ATLAS du LHC a des pions charges, d'energie comprise entre 3 et 350 Gev

    Energy Technology Data Exchange (ETDEWEB)

    Giangiobbe Vincent [Ecole Doctorale des Sciences Fondamentales, Universite Blaise Pascal, U.F.R de Recherches Scientifiques et Techniques, 34, avenue Carnot - BP 185, 63006 Clermont-Ferrand Cedex (France)

    2006-11-15

    ATLAS is one of the four main experiments under way of installing within the Large Hadron Project (LHC). LHC will provide two proton beams of high luminosity (1 x 10{sup 34} cm{sup -2} s{sup -1} at peak), colliding in the center of ATLAS detector at a 14 TeV rated COM energy. The aim of this study is an in-beam test characterization of the response of calorimeters in the central part of ATLAS. The study will be focused on the response to pions as main jet components. In the beginning a short presentation of the ATLAS program of physics is given enlightening the basic theoretical and experimental aspects of the experiment. A description of the ATLAS detector is also presented. The second chapter is devoted to detailed description of the central calorimetry of ATLAS. One starts from the mechanism of signal production in calorimeters, through the electronic processing up to the reconstruction of the released energy. The third chapter deals with the processing electronics of the TileCal hadron calorimeter the installation and certification at CERN of which was in charge of Clermont-Ferrand team. The chapter 4 gives a description of the SPS beam line and of the associated instrumentation tested in-beam in 2004. The chapters 6 and 7 are devoted to the study of the response of calorimeters to high energy pions (within 20 to 350 GeV range). The pion selection is described in the chapter 5. In the eighth chapter the calorimeter response to low energy pions (up to 9 GeV) is examined. In conclusion this study has shown that the data concerning pions obtained in-beam in 2004 are usable for energies within 3 to 350 GeV. The response and the energy resolution of LAr and TileCal were measured with a satisfactory accuracy,. A systematic comparison of these results with simulations (in the configuration of in-beam test) can now be done. Should the agreement be satisfying, the modelling could be used for the study of calibration of calorimeter response for the case of works with the

  19. An in-beam test study of the response of calorimeters in the ATLAS Experiment of LHC to charged pions of 3 to 350 GeV energy range; Etude en faisceau-test de la reponse des calorimetres de l'Experience ATLAS du LHC a des pions charges, d'energie comprise entre 3 et 350 Gev

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Giangiobbe [Ecole Doctorale des Sciences Fondamentales, Universite Blaise Pascal, U.F.R de Recherches Scientifiques et Techniques, 34, avenue Carnot - BP 185, 63006 Clermont-Ferrand Cedex (France)

    2006-11-15

    ATLAS is one of the four main experiments under way of installing within the Large Hadron Project (LHC). LHC will provide two proton beams of high luminosity (1 x 10{sup 34} cm{sup -2} s{sup -1} at peak), colliding in the center of ATLAS detector at a 14 TeV rated COM energy. The aim of this study is an in-beam test characterization of the response of calorimeters in the central part of ATLAS. The study will be focused on the response to pions as main jet components. In the beginning a short presentation of the ATLAS program of physics is given enlightening the basic theoretical and experimental aspects of the experiment. A description of the ATLAS detector is also presented. The second chapter is devoted to detailed description of the central calorimetry of ATLAS. One starts from the mechanism of signal production in calorimeters, through the electronic processing up to the reconstruction of the released energy. The third chapter deals with the processing electronics of the TileCal hadron calorimeter the installation and certification at CERN of which was in charge of Clermont-Ferrand team. The chapter 4 gives a description of the SPS beam line and of the associated instrumentation tested in-beam in 2004. The chapters 6 and 7 are devoted to the study of the response of calorimeters to high energy pions (within 20 to 350 GeV range). The pion selection is described in the chapter 5. In the eighth chapter the calorimeter response to low energy pions (up to 9 GeV) is examined. In conclusion this study has shown that the data concerning pions obtained in-beam in 2004 are usable for energies within 3 to 350 GeV. The response and the energy resolution of LAr and TileCal were measured with a satisfactory accuracy,. A systematic comparison of these results with simulations (in the configuration of in-beam test) can now be done. Should the agreement be satisfying, the modelling could be used for the study of calibration of calorimeter response for the case of works with the

  20. Calorimetric assay of HTGR fuel samples

    International Nuclear Information System (INIS)

    Allen, E.J.; McNeany, S.R.; Jenkins, J.D.

    1979-04-01

    A calorimeter using a neutron source was designed and fabricated by Mound Laboratory, according to ORNL specifications. A calibration curve of the device for HTGR standard fuel rods was experimentally determined. The precision of a single measurement at the 95% confidence level was estimated to be +-0.8 μW. For a fuel sample containing 0.3 g 235 U and a neutron source containing 691 μg 252 Cf, this represents a relative standard deviation of 0.5%. Measurement time was approximately 5.5 h per sample. Use of the calorimeter is limited by its relatively poor precision, long measurement time, manual sample changing, sensitivity to room environment, and possibility of accumulated dust blocking water flow through the calorimeter. The calorimeter could be redesigned to resolve most of these difficulties, but not without significant development work

  1. Measurement of ion energy by a calorimetric method

    Energy Technology Data Exchange (ETDEWEB)

    Mizuhashi, Kiyoshi; Tajima, Satoshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Bunak, Suwat

    1996-12-01

    In calorimetric method, ion energy is determined based on the temperature changes during radiation of an absorbing material, radiation current and heat capacity of the calorimeter. This method is convenient and its measuring procedures are simple as well as the measuring apparatus. Here, the temperature changes of the calorimeter during {sup 14}N ion beam radiation were determined. The temperature increased linearly when irradiated with {sup 14}N{sup 3+}, 8.3 MeV or {sup 14}N{sup 2+}, 6 MeV, but not linearly for {sup 14}N{sup 1+}, 3.6 MeV, resulting in a comparatively large error. Thus, the measurement of ion energy by calorimetric method was found available as a convenient method for an accelerator having an energy stability less than 10{sup -3}. Especially this method seems to be useful for low-energy ion accelerator or ion injecting apparatus. (M.N.)

  2. New methodology for simultaneous volumetric and calorimetric measurements: Direct determination of {alpha}{sub p} and C{sub p} for liquids under pressure

    Energy Technology Data Exchange (ETDEWEB)

    Casas, L. M. [Departamento de Fisica Aplicada, Facultad de Ciencias Experimentales, Universidad de Vigo, Lagoas Marcosende s/n, 36310 Vigo (Spain); Plantier, F.; Bessieres, D. [Laboratoire de Thermodynamique et Energetique des Fluides Complexes-UMR 5150, Universite de Pau et des Pays de l' Adour, BP 1155, 64013 Pau (France)

    2009-12-15

    A new batch cell has been developed to measure simultaneously both isobaric thermal expansion and isobaric heat capacity from calorimetric measurements. The isobaric thermal expansion is directly proportional to the linear displacement of an inner flexible below and the heat capacity is calculated from the calorimetric signal. The apparatus used was a commercial Setaram C-80 calorimeter and together with this type of vessels can be operated up to 20 MPa and in the temperature range of 303.15-523.15 K, In this work, calibration was carried out using 1-hexanol and subsequently both thermophysical properties were determined for 3-pentanol, 3-ethyl-3-pentanol, and 1-octanol at atmospheric pressure, 5 and 10 MPa, and from 303.15 to 423.15 K in temperature. Finally experimental values were compared with the literature in order to validate this new methodology, which allows a very accurate determination of isobaric thermal expansion and isobaric heat capacity.

  3. Calorimetric dosimetry of reactor radiation; Kalorimetriska dozimetrija reaktorskog zracenja

    Energy Technology Data Exchange (ETDEWEB)

    Radak, B; Markovic, V; Draganic, I [Institute of Nuclear Sciences Boris Kidric, Odeljenje za radijacionu hemiju, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    Calorimetric dosimetry of reactor radiation is relatively new reactor dosimetry method and the number of relevant papers is rather small. Some difficulties in applying standard methods (chemical dosemeters, ionization chambers) exist because of the complexity of radiation. In general application of calorimetric dosemeters for measuring absorbed doses is most precise. In addition to adequate choice of calorimetric bodies there is a possibility of determining the yields of each component of the radiation mixture in the total absorbed dose. This paper contains a short review of the basic calorimetry methods and some results of measurements at the RA reactor in Vinca performed by isothermal calorimeter. Kalorimetrijska dozimetrija reaktorskog zracenja je relativno nova metoda dozimetrije reaktora i broj do sada objavljenih radova je vrlo skroman. S obzirom na slozenu prirodu zracenja postoje neke teskoce pri radu sa standardnim metodama (hemijski dozimetri, jonizacione komere). U principu, upotreba kalorimetra za merenje apsorbovanih doza je najegzaktnija. Osim toga, uz pogodni izbor kalorimetrijskih tela postoji mogucnost za odredjivanje doprinosa pojedinih komponenti smese zracenja u totalnoj apsorbovanoj dozi. U tekstu je dat kratak pregled osnovnih metoda kalorimetrije i neki rezultati merenja sa izotermskim kalorimetrom na reaktoru RA u Vinci.

  4. Development of a calorimetric system for electron beam dosimetry in radiation processing

    International Nuclear Information System (INIS)

    Banados P, H.E.

    1994-01-01

    A calorimetric system for electron beam dosimetry in radiation processing was developed. The system is composed of a graphite core calorimeter, the temperature measuring and electrical calibrating instrumentation, a microcomputer and the software for the system automation. The research aimed at the optimization of the project parameters, the development of advanced methodologies for calibrating the temperature sensor, the determination of the thermal capacity as a function of the temperature, the measurement of the absorbed dose, and the development of the software needed for the system operation. The operating range extends from 0.1 kGy to 30 kGy. The uncertainty in the measurement of the absorbed dose was estimated to be ± 1.8% at the 95% confidence level. Comparative tests of the absorbed dose measurements were made using the IPEN electron accelerator. The results obtained showed an excellent agreement between the absorbed dose determined by the calorimeter and the absorbed dose calculated from the nominal power delivered by the accelerator. (author). 67 refs, 63 figs, 2 tabs

  5. Volumetric and calorimetric properties of aqueous ionene solutions.

    Science.gov (United States)

    Lukšič, Miha; Hribar-Lee, Barbara

    2017-02-01

    The volumetric (partial and apparent molar volumes) and calorimetric properties (apparent heat capacities) of aqueous cationic polyelectrolyte solutions - ionenes - were studied using the oscillating tube densitometer and differential scanning calorimeter. The polyion's charge density and the counterion properties were considered as variables. The special attention was put to evaluate the contribution of electrostatic and hydrophobic effects to the properties studied. The contribution of the CH 2 group of the polyion's backbone to molar volumes and heat capacities was estimated. Synergistic effect between polyion and counterions was found.

  6. Encapsulation of UC--PuC mixture for calorimetric study

    International Nuclear Information System (INIS)

    Armstrong, R.E.; Link, R.P.

    1976-01-01

    Tantalum capsules lined with tantalum carbide were loaded with a mixture of uranium carbide-20 wt% plutonium carbide and sealed with an electron beam weld for use in Argonne National Laboratory calorimetric studies of reactor fuels. Experimental welding tests were made to determine optimum welding parameters. Special equipment available only at LLL was used and techniques were developed to perform the loading and welding operations without exposure to moisture or oxygen and with complete containment of the radioactive particles. Three capsules were successfully loaded, welded, tested, and delivered to ANL

  7. Electrostatic probe and calorimetric measurements in a DC cathodic arc

    International Nuclear Information System (INIS)

    Lepone, Alejandro; Marquez, Adriana; Kelly, Hector; Grondona, Diana

    2001-01-01

    Several results obtained from measurements with spherical Langmuir probes and a calorimetric technique in a dc cathodic arc are presented. The arc is operated at a current level of 100 A, with a Copper cathode, and with Oxygen gas at a pressure in the range 0.005 divide 0.2 mbar. The measurements were performed at different axial positions in the discharge chamber. It is found that the electron temperature decreases for larger axial positions or higher pressures, but the derivation of reliable values for the ion density and kinetic energy require the consideration of atomic processes between the plasma and gas particles

  8. Some examples of the estimation of error for calorimetric assay of plutonium-bearing solids

    International Nuclear Information System (INIS)

    Rodenburg, W.W.

    1977-04-01

    This report provides numerical examples of error estimation and related measurement assurance programs for the calorimetric assay of plutonium. It is primarily intended for users who do not consider themselves experts in the field of calorimetry. These examples will provide practical and useful information in establishing a calorimetric assay capability which fulfills regulatory requirements. 10 tables, 5 figures

  9. Calorimetric monitoring of the serum proteome in schizophrenia patients

    Energy Technology Data Exchange (ETDEWEB)

    Krumova, Sashka [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 21, Sofia 1113 (Bulgaria); Rukova, Blaga [Department of Medical Genetics, Medical University of Sofia, 2 Zdrave Str., Sofia 1431 (Bulgaria); Todinova, Svetla [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 21, Sofia 1113 (Bulgaria); Gartcheva, Lidia [National Specialized Hospital for Active Treating of Haematological Diseases, 6 Plovdivsko pole Str., Sofia 1756 (Bulgaria); Milanova, Vihra [Department of Psychiatry, Medical University of Sofia, 1 Sv. Georgi Sofiiski Str., Sofia 1431 (Bulgaria); Toncheva, Draga [Department of Medical Genetics, Medical University of Sofia, 2 Zdrave Str., Sofia 1431 (Bulgaria); Taneva, Stefka G., E-mail: stefka.germanova@ehu.es [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 21, Sofia 1113 (Bulgaria)

    2013-11-20

    Highlights: • DSC reveals modified thermal behavior of blood serum from schizophrenic patients. • The high-abundance portion of the serum proteome is thermally stabilized in Sz. • The Sz plasma thermograms are classified in four distinct calorimetric groups. • The effectiveness of drug treatment correlates with the plasma thermodynamic behavior. - Abstract: Schizophrenia (Sz) is a multifactorial mental disorder with high frequency. Due to its chronic and relapsing nature there is a strong need for biomarkers for early psychosis detection and objective evaluation of drug (usually antipsychotics) treatment effect. Here differential scanning calorimetry (DSC) is applied to thermodynamically characterize the blood serum proteome of paranoid schizophrenia patients on routine antipsychotic treatment in comparison to healthy controls. DSC revealed significant modifications in the thermodynamic behavior of blood sera from Sz patients, the overall thermal profile being changed in all Sz cases under study. The calorimetric profiles were classified in four distinct groups, reflecting different thermal stabilization of the high-abundance portion of the serum proteome. The observed positive (thermograms becoming closer to the healthy profile) or negative (thermograms deviating stronger from the healthy profile) proteome thermal stability switches and the Sz thermograms persistence in patients’ follow-up corresponded well with the effect of drug treatment.

  10. Calorimetric monitoring of the serum proteome in schizophrenia patients

    International Nuclear Information System (INIS)

    Krumova, Sashka; Rukova, Blaga; Todinova, Svetla; Gartcheva, Lidia; Milanova, Vihra; Toncheva, Draga; Taneva, Stefka G.

    2013-01-01

    Highlights: • DSC reveals modified thermal behavior of blood serum from schizophrenic patients. • The high-abundance portion of the serum proteome is thermally stabilized in Sz. • The Sz plasma thermograms are classified in four distinct calorimetric groups. • The effectiveness of drug treatment correlates with the plasma thermodynamic behavior. - Abstract: Schizophrenia (Sz) is a multifactorial mental disorder with high frequency. Due to its chronic and relapsing nature there is a strong need for biomarkers for early psychosis detection and objective evaluation of drug (usually antipsychotics) treatment effect. Here differential scanning calorimetry (DSC) is applied to thermodynamically characterize the blood serum proteome of paranoid schizophrenia patients on routine antipsychotic treatment in comparison to healthy controls. DSC revealed significant modifications in the thermodynamic behavior of blood sera from Sz patients, the overall thermal profile being changed in all Sz cases under study. The calorimetric profiles were classified in four distinct groups, reflecting different thermal stabilization of the high-abundance portion of the serum proteome. The observed positive (thermograms becoming closer to the healthy profile) or negative (thermograms deviating stronger from the healthy profile) proteome thermal stability switches and the Sz thermograms persistence in patients’ follow-up corresponded well with the effect of drug treatment

  11. Optimization studies on the calorimetric second level tau trigger of the ATLAS experiment at the Large Hadron Collider

    CERN Document Server

    Perez Codina, Estel

    2008-01-01

    Moving to the high energy regime of LHC, the identification of tau leptons will become an important and very powerful tool, allowing the discovery of physics beyond the Standard Model. Many models, light SM Higgs and various SUSY models among them, predict an abundant production of taus with respect to other leptons. The ATLAS collaboration has developed tools to efficiently identify tau at trigger level, based on the advanced calorimetry and tracking capabilities. The work presented in this Master Thesis is focused on the optimization of the first trigger level energy thresholds and the second trigger level calorimetric variables. A systematic optimization is designed, which allows us to study the robustness of the trigger selection. The improvements achieved by using a sampling energy calibration are discussed. Finally, an optimization on the size of the calorimeter region used to calculate the trigger variables is performed.

  12. Calorimetric low temperature detectors for heavy ion physics

    Energy Technology Data Exchange (ETDEWEB)

    Egelhof, P.; Kraft-Bermuth, S. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)]|[Mainz Univ. (Germany). Inst. fuer Physik

    2005-05-01

    Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics at present and at the next generation heavy ion facilities is given with a special emphasis on the conditions for heavy ion detection and the potential advantage of cryogenic detectors for applications in heavy ion physics. Two types of calorimetric low temperature detectors for the detection of energetic heavy ions have been developed and their response to the impact of heavy ions was investigated systematically for a wide range of energies (E=0.1-360 MeV/amu) and ion species ({sup 4}He.. {sup 238}U). Excellent results with respect to energy resolution, {delta}E/E ranging from 1 to 5 x 10{sup -3} even for the heaviest ions, and other basic detector properties such as energy linearity with no indication of a pulse height defect, energy threshold, detection efficiency and radiation hardness have been obtained, representing a considerable improvement as compared to conventional heavy ion detectors based on ionization. With the achieved performance, calorimetric low temperature detectors bear a large potential for applications in various fields of basic and applied heavy ion research. A brief overview of a few prominent examples, such as high resolution nuclear spectroscopy, high resolution nuclear mass determination, which may be favourably used for identification of superheavy elements or in direct reaction experiments with radioactive beams, as well as background discrimination in accelerator mass spectrometry, is given, and first results are presented. For instance, the use of cryogenic detectors allowed to improve the sensitivity in trace analysis of {sup 236}U by one order of magnitude and to determine the up to date smallest isotope ratio of {sup 236}U/{sup 238}U = 6.1 x 10{sup -12} in a sample of natural uranium. Besides the detection of heavy ions, the concept of cryogenic detectors also

  13. Calorimetric low temperature detectors for heavy ion physics

    International Nuclear Information System (INIS)

    Egelhof, P.; Kraft-Bermuth, S.; Mainz Univ.

    2005-07-01

    Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics at present and at the next generation heavy ion facilities is given with a special emphasis on the conditions for heavy ion detection and the potential advantage of cryogenic detectors for applications in heavy ion physics. Two types of calorimetric low temperature detectors for the detection of energetic heavy ions have been developed and their response to the impact of heavy ions was investigated systematically for a wide range of energies (E=0.1-360 MeV/amu) and ion species ( 4 He.. 238 U). Excellent results with respect to energy resolution, ΔE/E ranging from 1 to 5 x 10 -3 even for the heaviest ions, and other basic detector properties such as energy linearity with no indication of a pulse height defect, energy threshold, detection efficiency and radiation hardness have been obtained, representing a considerable improvement as compared to conventional heavy ion detectors based on ionization. With the achieved performance, calorimetric low temperature detectors bear a large potential for applications in various fields of basic and applied heavy ion research. A brief overview of a few prominent examples, such as high resolution nuclear spectroscopy, high resolution nuclear mass determination, which may be favourably used for identification of superheavy elements or in direct reaction experiments with radioactive beams, as well as background discrimination in accelerator mass spectrometry, is given, and first results are presented. For instance, the use of cryogenic detectors allowed to improve the sensitivity in trace analysis of 236 U by one order of magnitude and to determine the up to date smallest isotope ratio of 236 U/ 238 U = 6.1 x 10 -12 in a sample of natural uranium. Besides the detection of heavy ions, the concept of cryogenic detectors also provides considerable advantage for X

  14. Calibration uncertainty

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Anglov, Thomas

    2002-01-01

    Methods recommended by the International Standardization Organisation and Eurachem are not satisfactory for the correct estimation of calibration uncertainty. A novel approach is introduced and tested on actual calibration data for the determination of Pb by ICP-AES. The improved calibration...

  15. Calorimetric investigation of an yttrium-dysprosium spin glass

    International Nuclear Information System (INIS)

    Wenger, L.E.

    1978-01-01

    In an effort to compare the spin glass characteristics of yttrium--rare earth alloys with those of the noble-metal spin glasses, the susceptibility and heat capacity of Y/sub 0.98/Dy/sub 0.02/ have been measured in the temperature range 2.5--40 K. The low-field ac susceptibility measurement shows the characteristic cusp-like peak at 7.64 K. The magnetic specific heat of the same sample shows a peak at 7.0 K and may be qualitatively described as a semi-cusp. The magnetic entropy change from absolute zero to 7 K is approximately 0.52 of cR ln(2J+1). These results are qualitatively different than previous calorimetric results on the archetypal spin glasses, AuFe and CuMn, where rounded maxima are observed at temperatures above the spin glass transition temperatures

  16. Calorimetric signature of structural heterogeneity in a ternary silicate glass

    DEFF Research Database (Denmark)

    Zhang, Yanfei; Yang, G.; Yue, Yuanzheng

    2013-01-01

    We investigate the structural heterogeneity in a silicate glass by hyperquenching–annealing–calorimetry approach. The results show a striking phenomenon: two separated sub-Tg relaxation peaks appear on the calorimetric curve of the hyperquenched CaO–MgO–SiO2 glass, implying the existence of two...... distinct structural domains of higher and lower potential energies, respectively. The higher energy domains in nanoscale are so unstable that they become ordered during hyperquenching. This is verified by the high-resolution transmission electron microscopy image exhibiting nanoordered domains in the glass...... matrix. The higher energy domains relax similar to a strong glass phase, whereas the lower energy domains do similar to a fragile one....

  17. The application of calorimetrical methods in nuclear technology and dosimetry

    International Nuclear Information System (INIS)

    Kott, J.; Krett, V.; Novotny, J.; Kovar, Z.; Jirousek, V.

    1985-01-01

    The report reviews theoretical as well as experimental research activities devoted to the possibilities of measuring reactor neutron and photon fields using thermic detectors based on calorimetric principle. There have been worked out theoretical principles of a reactor measuring probe intended in the first place to measuring neutron fluxes under operational temperatures inside power and research reactors, and a new philosophy of measurement has been elaborated. In addition, the report presents the experimental results as obtained on research reactors WWR-S, WWR-SM, RA, and Czechoslovak power reactor A-1 and GDR power reactor WWR-2. These results are given in connection with a newly proposed technique of reactor neutron field detection. The second part of the report presents results of works concerning beam dosimetry with the use of calorimeters

  18. Remote calorimetric detection of urea via flow injection analysis.

    Science.gov (United States)

    Gaddes, David E; Demirel, Melik C; Reeves, W Brian; Tadigadapa, Srinivas

    2015-12-07

    The design and development of a calorimetric biosensing system enabling relatively high throughput sample analysis are reported. The calorimetric biosensor system consists of a thin (∼20 μm) micromachined Y-cut quartz crystal resonator (QCR) as a temperature sensor placed in close proximity to a fluidic chamber packed with an immobilized enzyme. Layer by layer enzyme immobilization of urease is demonstrated and its activity as a function of the number of layers, pH, and time has been evaluated. This configuration enables a sensing system where a transducer element is physically separated from the analyte solution of interest and is thereby free from fouling effects typically associated with biochemical reactions occuring on the sensor surface. The performance of this biosensing system is demonstrated by detection of 1-200 mM urea in phosphate buffer via a flow injection analysis (FIA) technique. Miniaturized fluidic systems were used to provide continuous flow through a reaction column. Under this configuration the biosensor has an ultimate resolution of less than 1 mM urea and showed a linear response between 0-50 mM. This work demonstrates a sensing modality in which the sensor itself is not fouled or contaminated by the solution of interest and the enzyme immobilized Kapton® fluidic reaction column can be used as a disposable cartridge. Such a system enables reuse and reliability for long term sampling measurements. Based on this concept a biosensing system is envisioned which can perform rapid measurements to detect biomarkers such as glucose, creatinine, cholesterol, urea and lactate in urine and blood continuously over extended periods of time.

  19. Calibration factor or calibration coefficient?

    International Nuclear Information System (INIS)

    Meghzifene, A.; Shortt, K.R.

    2002-01-01

    Full text: The IAEA/WHO network of SSDLs was set up in order to establish links between SSDL members and the international measurement system. At the end of 2001, there were 73 network members in 63 Member States. The SSDL network members provide calibration services to end-users at the national or regional level. The results of the calibrations are summarized in a document called calibration report or calibration certificate. The IAEA has been using the term calibration certificate and will continue using the same terminology. The most important information in a calibration certificate is a list of calibration factors and their related uncertainties that apply to the calibrated instrument for the well-defined irradiation and ambient conditions. The IAEA has recently decided to change the term calibration factor to calibration coefficient, to be fully in line with ISO [ISO 31-0], which recommends the use of the term coefficient when it links two quantities A and B (equation 1) that have different dimensions. The term factor should only be used for k when it is used to link the terms A and B that have the same dimensions A=k.B. However, in a typical calibration, an ion chamber is calibrated in terms of a physical quantity such as air kerma, dose to water, ambient dose equivalent, etc. If the chamber is calibrated together with its electrometer, then the calibration refers to the physical quantity to be measured per electrometer unit reading. In this case, the terms referred have different dimensions. The adoption by the Agency of the term coefficient to express the results of calibrations is consistent with the 'International vocabulary of basic and general terms in metrology' prepared jointly by the BIPM, IEC, ISO, OIML and other organizations. The BIPM has changed from factor to coefficient. The authors believe that this is more than just a matter of semantics and recommend that the SSDL network members adopt this change in terminology. (author)

  20. Reactivity of Monolayer Protected Silver Clusters Towards Excess Ligand: A Calorimetric Study

    KAUST Repository

    Baksi, Ananya; Bootharaju, Megalamane Siddaramappa; Chhotaray, Pratap K.; Chakraborty, Papri; Mondal, Biswajit; Bhat, Shridevi; Gardas, Ramesh L.; Pradeep, Thalappil

    2017-01-01

    Reactivity of monolayer protected atomically precise clusters of noble metals is of significant research interest. Till date very few experimental data are available on the reaction thermodynamics of such clusters. Here we report a calorimetric

  1. Calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid

    International Nuclear Information System (INIS)

    Kurbanov, A.R.; Sharipov, D.Sh.

    1993-01-01

    Present article is devoted to calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid. The calorimetric study of interaction of barium hydroxide with diluted solutions of hydrofluoric acid was carried out in order to determine the thermal effects of reactions. The results of interaction of Ba(OH) 4 ·8H 2 O with 5, 10, and 20% solution of hydrofluoric acid were considered.

  2. Calorimetric measurements of $^{163}$ holmium decay as tools to determine the electron neutrino mass

    CERN Document Server

    De Rújula, Alvaro

    1982-01-01

    Computes the spectrum of 'calorimetric' energy in the electron capture decay of /sup 163/Ho. A calorimetric experiment would yield an excellent determination of (/sup 163/Ho, /sup 163/Dy) mass difference. The proximity of the spectral endpoint to an atomic resonance makes the fraction of events that are sensitive to a non-zero neutrino mass superior in /sup 163/Ho decay than in tritium decay.

  3. Calorimetric and relaxation properties of xylitol-water mixtures

    Science.gov (United States)

    Elamin, Khalid; Sjöström, Johan; Jansson, Helén; Swenson, Jan

    2012-03-01

    We present the first broadband dielectric spectroscopy (BDS) and differential scanning calorimetry study of supercooled xylitol-water mixtures in the whole concentration range and in wide frequency (10-2-106 Hz) and temperature (120-365 K) ranges. The calorimetric glass transition, Tg, decreases from 247 K for pure xylitol to about 181 K at a water concentration of approximately 37 wt. %. At water concentrations in the range 29-35 wt. % a plentiful calorimetric behaviour is observed. In addition to the glass transition, almost simultaneous crystallization and melting events occurring around 230-240 K. At higher water concentrations ice is formed during cooling and the glass transition temperature increases to a steady value of about 200 K for all higher water concentrations. This Tg corresponds to an unfrozen xylitol-water solution containing 20 wt. % water. In addition to the true glass transition we also observed a glass transition-like feature at 220 K for all the ice containing samples. However, this feature is more likely due to ice dissolution [A. Inaba and O. Andersson, Thermochim. Acta, 461, 44 (2007)]. In the case of the BDS measurements the presence of water clearly has an effect on both the cooperative α-relaxation and the secondary β-relaxation. The α-relaxation shows a non-Arrhenius temperature dependence and becomes faster with increasing concentration of water. The fragility of the solutions, determined by the temperature dependence of the α-relaxation close to the dynamic glass transition, decreases with increasing water content up to about 26 wt. % water, where ice starts to form. This decrease in fragility with increasing water content is most likely caused by the increasing density of hydrogen bonds, forming a network-like structure in the deeply supercooled regime. The intensity of the secondary β-relaxation of xylitol decreases noticeably already at a water content of 2 wt. %, and at a water content above 5 wt. % it has been replaced by a

  4. Calorimetric measurements on refractory metals and alloys by means of electromagnetic levitation (Paper No. 42)

    International Nuclear Information System (INIS)

    Frohberg, M.G.; Betz, Gerhard

    1979-01-01

    Conventional calorimetric measurements for determining the enthalpy of solid and liquid metals or alloys have an upper temperature limit of around 1800-2000deg C. This limit is given by the thermal durability of the crucible material. To avoid these disadvantages, combination of levitation melting and drop calorimeter (levitation calorimetry) was performed in the last years. A critical analysis of the published works, however, shows that the temperature measurement and the determination of the temperature loss of the specimen during its falling period is still the problem. In consideration of these special circumstances, a levitation calorimeter was built in the Institute of Metallurgy of Technical University, Berlin. It consists of an evacuable levitation chamber. The levitation coil is connected via a transformator to a 25 KVA 500 KHz generator. The temperature of the specimen (weight 4-9 g) is measured and recorded by two different optical ways. The connected drop calorimeter is working isoperibolic. Its main part is a block of copper with a conical borehole for accepting the specimen. This copper block lies within a greater steel container which itself is in a water thermostat of a temperature 25deg C. In order to determine the calorimeter constant the calibration can be done by electrical means. To determine the temperature loss (5-10% error in enthalpy values) during the falling period between levitation coil and calorimeter many theoretical works and practical experiments have been done. First experiments on solid molybdenum in the temperature range of 2280-2750 K show a high accuracy of the measured values. Deviation from proposed ''best curve'' of Hultgreen is better than 0.3%. (auth.)

  5. Atlas barrel electromagnetic calorimeter performance study. Measurement of the Forward-Backward asymmetry in the qq-bar {yields} Z/{gamma}{sup *} {yields} e{sup +}e{sup -} events; Etude des performances du calorimetre electromagnetique tonneau d'ATLAS. Mesure de l'asymetrie Avant-Arriere dans les evenements qq-bar {yields} Z/{gamma}{sup *} {yields} e{sup +}e{sup -}

    Energy Technology Data Exchange (ETDEWEB)

    Aharrouche, M

    2006-12-15

    The start up of the ATLAS experiment at the CERN LHC is planned for the year 2007. The physics program of the experiment covers a wide field, going from tests of Standard Model (Higgs boson discovery) to new theories beyond the Standard Model (Supersymmetry, extra dimensions... etc). The work presented in this thesis has been made within the framework of the preparation of this experiment. After having presented the 2004 combined run, its installation, pedestal data and calibration data analysis, we develop a method for calibrating the energy measurement based on Geant4 Monte-Carlo simulation of the combined run. These simulations are done in the general framework developed for the analysis of the ATLAS data. We present then the performance studies of the electromagnetic calorimeter as well as the results obtained: a sampling term of the energy resolution of 10.6% GeV and local constant term of 0.43%, a non-uniformity of response of 0.44% giving a total constant term of 0.6% and a linearity better than 0.2% for electrons energies between 20 and 250 GeV. Concerning the 'physics' side of this thesis, we show a first study on the determination of the effective weak mixing angle, sin{sup 2}({theta}(lept,eff) with one precision better than the current results, 10{sup -4}. To reach such a precision it has been necessary to identify the electrons in the forward regions of the detector. This point is the subject of the last part of this manuscript, it shows that one can reach an electron-jet rejection of 100 with an efficiency of the electrons reconstruction of 50%, by using a discriminating analysis based on the methods of Fisher, the likelihood and the neural networks. (author)

  6. Calorimetric signatures of human cancer cells and their nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Todinova, S. [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 21, Sofia 1113 (Bulgaria); Stoyanova, E. [Department of Molecular Immunology, Institute of Biology and Immunology of Reproduction, Bulgarian Academy of Sciences, Tzarigradsko shose Blvd. 73, Sofia 1113 (Bulgaria); Krumova, S., E-mail: sakrumo@gmail.com [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 21, Sofia 1113 (Bulgaria); Iliev, I. [Institute of Experimental Morphology, Pathology and Anthropology with Museum, Acad. G. Bonchev Str., Bl. 25, Sofia 1113 (Bulgaria); Taneva, S.G. [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., Bl. 21, Sofia 1113 (Bulgaria)

    2016-01-10

    Graphical abstract: - Highlights: • Two temperature ranges are distinguished in the thermograms of cells/nuclei. • Different thermodynamic properties of cancer and normal human cells/nuclei. • Dramatic reduction of the enthalpy of the low-temperature range in cancer cells. • Oxaliplatin and 5-FU affect the nuclear matrix proteins and the DNA stability. - Abstract: The human cancer cell lines HeLa, JEG-3, Hep G2, SSC-9, PC-3, HT-29, MCF7 and their isolated nuclei were characterized by differential scanning calorimetry. The calorimetric profiles differed from normal human fibroblast (BJ) cells in the two well distinguished temperature ranges—the high-temperature range (H{sub T}, due to DNA-containing structures) and the low-temperature range (L{sub T}, assigned to the nuclear matrix and cellular proteins). The enthalpy of the L{sub T} range, and, respectively the ratio of the enthalpies of the L{sub T}- vs. H{sub T}-range, ΔH{sub L}/ΔH{sub H}, is strongly reduced for all cancer cells compared to normal fibroblasts. On the contrary, for most of the cancer nuclei this ratio is higher compared to normal nuclei. The HT-29 human colorectal cancer cells/nuclei differed most drastically from normal human fibroblast cells/nuclei. Our data also reveal that the treatment of HT-29 cancer cells with cytostatic drugs affects not only the DNA replication but also the cellular proteome.

  7. Calorimetric approach of lanthanides (3) complexation and extraction by malonamides

    International Nuclear Information System (INIS)

    Flandin, J.L.

    2001-01-01

    In the field of long lived radionuclides separation, diamides are interesting extractants because of their ability to co-extract trivalent lanthanides and actinides, which is a preliminary and essential step in high level radioactive waste reprocessing. The research carried out contributes to a better understanding of the mechanisms and the aim is the determination of thermodynamics properties (Δ r G, Δ r H et Δ r S) related to the complexation and the extraction of lanthanides(III) by malonamides. The first part of the document deals with the complexation of lanthanides(III) by an hydrosoluble diamide. The experimental results obtained by UV-visible spectrometry, TRLIF, NMR and microcalorimetric titration proved that lanthanides(III)-TEMA interactions in aqueous medium are very weak and that the complexation reaction is endothermic. The TEMA ligand still stays in the second coordination sphere of coordination of the lanthanide ion. The second part of this study focuses on the extraction of neodymium(III) nitrate by a lipophilic diamide which is an exothermic reaction. The influence of the composition of aqueous and organic phases on the thermodynamics properties Δ r G et Δ r H has been studied by microcalorimetric titration. The most influent parameter is the total concentration in extractant. As a consequence, thermodynamic values are very dependent on the organic phase organisation before and alter extraction. At the same time, this study showed the interest of the calorimetric approach for the analysis of basic reactions like diamide dilution and their organisation as oligomeric aggregates. (author)

  8. Calorimetric and ionometric dosimetry for cyclotron produced fast neutrons

    International Nuclear Information System (INIS)

    McDonald, J.C.; Ma, I.C.; Laughlin, J.S.

    1977-01-01

    A portable tissue equivalent (TE) calorimeter, constructed of A-150 plastic, has been employed for the measurement of absorbed dose in two fast neutron fields produced by the 9 Be( 3 He,n) and 9 Be(d,n) interactions. A disc shaped ionization chamber has also been constructed of A-150 plastic and has a collecting volume geometrically equivalent to the calorimeter core (2 cm in diameter and 0.2 cm thick). A flow of methane compounded TE gas was maintained through the chamber at a rate of approximately 5 cc/min during the measurements. The ionization chamber was mounted within an irradiation enclosure which simulated the outer dimensions of the calorimeter housing. In this way, both detectors were placed at the same depth in TE plastic and each received approximately the same scattered radiation. The gamma-ray component of absorbed dose has been determined by the use of a miniature Geiger-Mueller dosimeter. It was found that the response sensitivity ratio for the TE ionization chamber in the two neutron fields relative to the 60 Co gamma-ray field, when normalized to the absorbed dose measured by the TE calorimeter, was approximately 1.07. Uncertainties in these calorimetric and ionometric methods for the measurements of the absorbed dose will be discussed along with measurements of the thermal defect for A-150 TE plastic

  9. Calorimetric measurements on slightly soluble gases in water

    International Nuclear Information System (INIS)

    Olofsson, G.; Oshodj, A.A.; Qvarnstroem, E.; Wadsoe, I.

    1984-01-01

    Calorimetric measurements have been made of enthalpies of solution Δsub(sol)Hsub(m)sup(infinity) in water of helium, neon, argon, krypton, xenon, methane, ethane, propane, n-butane, and oxygen at 288.15, 298.15, and 308.15 K. Values of the heat-capacity changes Δsub(sol)Csub(p,m)sup(infinity) have been derived. The found values for both the enthalpy and heat-capacity changes for the rare gases and for oxygen fully confirm the values derived by Benson and Krause, Jr. (1976), and Benson, Krause, Jr., and Peterson (1979) from the results of their very careful gas-solubility measurements. The partial molar heat capacities Csub(p,2)sup(infinity) of the hydrocarbons studied were derived. The group-additivity schemes that have been used successfully for the estimation of values for Csub(p,2)sup(infinity) for various non-ionic organic compounds do not correctly predict values of Csub(p,2)sup(infinity) for the hydrocarbons in the present study. (author)

  10. Particle Beam Tests of the Calorimetric Electron Telescope

    CERN Document Server

    Tamura, Tadahisa

    The Calorimetric Electron Telescope (CALET) is a new mission addressing outstanding astrophysics questions including the nature of dark matter, the sources of high-energy particles and photons, and the details of particle acceleration and transport in the galaxy by measuring the high-energy spectra of electrons, nuclei, and gamma-rays. It will launch on HTV-5 (H-II Transfer Vehicle 5) in 2014 for installation on the Japanese Experiment Module–Exposed Facility (JEM-EF) of the International Space Station. The CALET collaboration is led by JAXA and includes researchers from Japan, the U.S. and Italy. The CALET Main Telescope uses a plastic scintillator charge detector followed by a 30 radiation-length (X0) deep particle calorimeter divided into a 3 X0 imaging calorimeter, with scintillating optical fibers interleaved with thin tungsten sheets, and a 27 X0 fully-active total-absorption calorimeter made of lead tungstate scintillators. CALET prototypes were tested at the CERN (European Laboratory for Particle Ph...

  11. Investigation of sodium - carbon dioxide interactions with calorimetric studies

    International Nuclear Information System (INIS)

    Simon, N.; Latge, C.; Gicquel, L.

    2007-01-01

    The supercritical CO 2 Brayton cycle could be a promising option to enhance the competitiveness of future Sodium fast reactors but it is highly necessary to get thermodynamic and kinetics information on potential sodium-CO 2 chemical reactions and their consequences. We have studied the interaction between Na and CO 2 via calorimetric methods. These methods are able to point out exothermic/endothermic phenomena and to measure heat of chemical reactions. The main feature of the Na/CO 2 interaction seems to be its sharp dependence on temperature. At low temperature, below 500 C degrees, CO 2 and sodium react and exhibit an induction time which decreases when temperature increases. Above 500 C degrees, we observe a global phenomenon with a fast and instantaneous chemical reaction which may be understood as an auto-combustion of CO 2 in sodium. We clearly demonstrated that Na/CO 2 interaction does not proceed as an auto-catalytic process and is more satisfactorily explained by the occurring of an auto-combustion phenomenon

  12. Sorption of organic chemicals at biogeochemical interfaces - calorimetric measurements

    Science.gov (United States)

    Krüger, J.; Lang, F.; Siemens, J.; Kaupenjohann, M.

    2009-04-01

    Biogeochemical interfaces in soil act as sorbents for organic chemicals, thereby controlling the degradation and mobility of these substances in terrestrial environments. Physicochemical properties of the organic chemicals and the sorbent determine sorptive interactions. We hypothesize that the sorption of hydrophobic organic chemicals ("R-determined" chemicals) is an entropy-driven partitioning process between the bulk aqueous phase and biogeochemical interface and that the attachment of more polar organic chemicals ("F-determined" chemicals) to mineral surfaces is due to electrostatic interactions and ligand exchange involving functional groups. In order to determine thermodynamic parameters of sorbate/sorbent interactions calorimetric titration experiments have been conducted at 20˚ C using a Nanocalorimeter (TAM III, Thermometric). Solutions of different organic substances ("R-determined" chemicals: phenanthrene, bisphenol A, "F-determined" chemicals: MCPA, bentazone) with concentrations of 100 mol l-1 were added to suspensions of pure minerals (goethite, muscovite, and kaolinite and to polygalacturonic acid (PGA) as model substance for biofilms in soil. Specific surface, porosity, N and C content, particle size and point of zero charge of the mineral were analyzed to characterize the sorbents. The obtained heat quantities for the initial injection of the organic chemicals to the goethite were 55 and 71 J for bisphenol A and phenanthrene ("R-determined representatives") and 92 and 105 J for MCPA and bentazone ("F-determined" representatives). Further experiments with muscovite, kaolinite and PGA are in progress to determine G and H of the adsorption process.

  13. Model for calorimetric measurements in an open quantum system

    Science.gov (United States)

    Donvil, Brecht; Muratore-Ginanneschi, Paolo; Pekola, Jukka P.; Schwieger, Kay

    2018-05-01

    We investigate the experimental setup proposed in New J. Phys. 15, 115006 (2013), 10.1088/1367-2630/15/11/115006 for calorimetric measurements of thermodynamic indicators in an open quantum system. As a theoretical model we consider a periodically driven qubit coupled with a large yet finite electron reservoir, the calorimeter. The calorimeter is initially at equilibrium with an infinite phonon bath. As time elapses, the temperature of the calorimeter varies in consequence of energy exchanges with the qubit and the phonon bath. We show how under weak-coupling assumptions, the evolution of the qubit-calorimeter system can be described by a generalized quantum jump process including as dynamical variable the temperature of the calorimeter. We study the jump process by numeric and analytic methods. Asymptotically with the duration of the drive, the qubit-calorimeter attains a steady state. In this same limit, we use multiscale perturbation theory to derive a Fokker-Planck equation governing the calorimeter temperature distribution. We inquire the properties of the temperature probability distribution close and at the steady state. In particular, we predict the behavior of measurable statistical indicators versus the qubit-calorimeter coupling constant.

  14. Thermally decarboxylated sodium bicarbonate: Interactions with water vapour, calorimetric study

    Directory of Open Access Journals (Sweden)

    Natalia Volkova

    2013-06-01

    Full Text Available Isothermal titration calorimetry (ITC was used to study interactions between water vapour and the surface of thermally converted sodium bicarbonate (NaHCO3. The decarboxylation degree of the samples was varied from 3% to 35% and the humidity range was 54–100%. The obtained enthalpy values were all exothermic and showed a positive linear correlation with decarboxylation degrees for each humidity studied. The critical humidity, 75% (RHo, was determined as the inflection point on a plot of the mean−ΔHkJ/mole Na2CO3 against RH. Humidities above the critical humidity lead to complete surface dissolution. The water uptake (m was determined after each calorimetric experiment, complementing the enthalpy data. A mechanism of water vapour interaction with decarboxylated samples, including the formation of trona and Wegscheider’s salt on the bicarbonate surface is proposed for humidities below RHo. Keywords: Isothermal titration calorimetry, Sodium bicarbonate, Sodium carbonate, Trona salt, Wegscheider’s salt, Enthalpy, Relative humidity, Pyrolytic decarboxylation

  15. Calorimetric investigations of UPb{sub 3} compound

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Renu, E-mail: arenu@barc.gov.in; Samui, Pradeep; Mukerjee, S.K.

    2016-08-10

    Highlights: • First time reporting of enthalpy increment and heat capacity data of UPb{sub 3} compound. • First time reporting of high temperature calorimetric determination of enthalpy of formation of UPb{sub 3} compound. • Miedema model was used to calculate enthalpies of formation of UPb{sub 3} and UPb. • Thermodynamic table of the compound UPb{sub 3} was generated. - Abstract: Interaction of uranium based metallic fuels and lead coolant can lead to formation of intermetallic compounds of U-Pb system. To understand U-Pb interactions, it is important to know thermodynamic properties of intermetallic compounds present in this system, UPb{sub 3} and UPb. In the present work, enthalpy increment, heat capacity and enthalpy of formation of UPb{sub 3} intermetallic compound were determined. The enthalpy increment was determined by high temperature Calvet calorimeter and heat capacity was determined using DSC. The heat capacity data was used to calculate thermodynamic parameters of the compound as a function of temperature. The enthalpy of formation at 843 K was determined using successive precipitation method, by direct reaction calorimetry. The enthalpy of formation at 843 K, from Pb(l) and U(l), was −28.9 kJ at-mol{sup −1} and after adjusting enthalpy increments of pure elements and compound, the enthalpy of formation of the compound at 298 K, from Pb(s) and U(α) was found to be −20.0 kJ at-mol{sup −1}.

  16. Tagging calibration of the jets from beauty quarks and the search for Higgs boson in the tt-bar H {yields} l{nu}b, jjb, bb-bar channel in the ATLAS experiment at LHC; Calibration de l'etiquetage de jets issus de quarks beaux et recherche du boson de Higgs dans le canal tt-barH {yields} l{nu}b, jjb, bb-bar dans l'experience ATLAS aupres du LHC

    Energy Technology Data Exchange (ETDEWEB)

    Correard, Sebastien [Faculte des Sciences de Luminy, Universite de la Mediterranee, Aix-Marseille II, 163 avenue de Luminy, 13288 Marseille cedex 09 (France)

    2006-02-15

    B-tagging calibration and search for the Higgs boson in the tt-bar H {yields} l{nu}b, jjb, bb-bar channel with ATLAS at LHC The ATLAS experiment, based at CERN, will use the LHC proton collisions to deepen the Standard Model measurements, and look for possible signs of new physics. One of its main tasks will be the search for the Higgs boson. This thesis first describes the latest b-tagging algorithms, shows the importance of its calibration, and proposes a b-tagging calibration method based on the first data recorded by ATLAS. Then, considering that the Higgs boson may be light (m{sub H} < 135 GeV/c{sup 2}), the ttH channel is studied, with H decaying in a b quark pair. Full simulation and the latest realistic b-tagging methods have been combined for the first time. For an integrated luminosity of 30 fb{sup -1} (3 years of data taking), the S/{radical}B ratio, determining the sensitivity of this analysis, is raised to 4.9. This should allow a non-ambiguous observation of the Higgs boson in this channel. (author)

  17. Fiche technique du spermogramme et du spermocytogramme ...

    African Journals Online (AJOL)

    En Afrique la stérilité du couple constitue un drame social. Selon l'OMS, environ 8 à 12 % des couples africains sont touchés par une infertilité. La responsabilité masculine dans la stérilité est comprise entre 30 à 40%. Les causes de l'infertilité masculine peuvent être l'impuissance et/ ou l'altération du sperme. L'étude de ...

  18. Calibration of the VIRGO experiment: from the testing of the detector to the search of coalescing binaries with the central interferometer; Calibration de l'experience VIRGO: de l'etalonnage du detecteur a la recherche de signaux de coalescences binaires avec l'interferometre central

    Energy Technology Data Exchange (ETDEWEB)

    Veziant, O

    2003-05-01

    The aim of the VIRGO experiment is the detection of gravitational waves. The detector is based on a Michelson interferometer with three-kilometer long arms. Before the availability of the complete detector, most of the technical choices have been tested on a small scale interferometer (central interferometer or CITF). This allowed to record the first technical data of the experiment. The calibration of the CITF data has been studied in this thesis. This work involved some local operations such as the calibration of the electronics of the detection system, and also some more global operation such as the characterisation of the detector response function. The latter is used to unfold the data from experimental effects and to estimate the detector sensitivity. A monitoring procedure of this response function has been applied to produce a time series of reconstructed data, i.e. data free from experimental distortions. The implementation of VIRGO will make use of an optical calibrator using the radiation pressure of a laser beam to act on the interferometer mirrors and characterize its response. The optical calibrator has been designed and assembled in laboratory and its performances have been measured. The physics analysis following the calibration step was tackled through a coalescing binary search algorithm. The latter was applied both on simulated data and on CITF data in order to estimate the detector noise level and to check the effects of the reconstruction procedure. (author)

  19. Selection of non-destructive assay methods: Neutron counting or calorimetric assay?

    International Nuclear Information System (INIS)

    Cremers, T.L.; Wachter, J.R.

    1994-01-01

    The transition of DOE facilities from production to D ampersand D has lead to more measurements of product, waste, scrap, and other less attractive materials. Some of these materials are difficult to analyze by either neutron counting or calorimetric assay. To determine the most efficacious analysis method, variety of materials, impure salts and hydrofluorination residues have been assayed by both calorimetric assay and neutron counting. New data will be presented together with a review of published data. The precision and accuracy of these measurements are compared to chemistry values and are reported. The contribution of the gamma ray isotopic determination measurement to the overall error of the calorimetric assay or neutron assay is examined and discussed. Other factors affecting selection of the most appropriate non-destructive assay method are listed and considered

  20. Effect of Heat Generation of Ultrasound Transducer on Ultrasonic Power Measured by Calorimetric Method

    Science.gov (United States)

    Uchida, Takeyoshi; Kikuchi, Tsuneo

    2013-07-01

    Ultrasonic power is one of the key quantities closely related to the safety of medical ultrasonic equipment. An ultrasonic power standard is required for establishment of safety. Generally, an ultrasonic power standard below approximately 20 W is established by the radiation force balance (RFB) method as the most accurate measurement method. However, RFB is not suitable for high ultrasonic power because of thermal damage to the absorbing target. Consequently, an alternative method to RFB is required. We have been developing a measurement technique for high ultrasonic power by the calorimetric method. In this study, we examined the effect of heat generation of an ultrasound transducer on ultrasonic power measured by the calorimetric method. As a result, an excessively high ultrasonic power was measured owing to the effect of heat generation from internal loss in the transducer. A reference ultrasound transducer with low heat generation is required for a high ultrasonic power standard established by the calorimetric method.

  1. Theoretical and experimental study of a calorimetric technique for measuring energy deposition in materials caused by complex pile irradiation; Etude theorique et experimentale d'une technique calorimetrique de mesure des depots d'energie dans les materiaux dus au rayonnement complexe de pile

    Energy Technology Data Exchange (ETDEWEB)

    Mas, P; Sciers, P; Droulers, Y [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires, 38 - Grenoble (France)

    1962-07-01

    Calorimetric methods may be used to measure gamma fluxes greater than 10{sup 6} r/h near the cores of swimming pool reactors. The theory, design, and properties of isothermal calorimeters are discussed, and experimental results obtained with two types are presented. Measurement of energy deposition in materials and the long term integration of energy depositions are other uses of these devices. Results of measurements on heat deposition in steel and water are given. Fluxes were also measured. (authors) [French] Une premiere partie traite de la theorie des calorimetres isothermes mis en oeuvre au C.K.N. Grenoble. La puissance deposee dans le calorimetre par les flux de rayonnement echauffe celui-ci. L'echauffement est mesure a l'aide d'un thermocouple. On montre que l'on a ainsi une mesure absolue de cette puissance. Une deuxieme partie traite de l'etude experimentale de: deux types d'appareils utilises: leur construction, les resultats experimentaux, leurs utilisations. Trois de celles-ci sont particulierement interessantes: - la mesure des hauts flux gamma, - la mesure du depot d'energie dans les materiaux, - l'integration pendant une longue duree des depots d'energie (un modele de calorimetre a fonctionne a ce jour 2 500 heures et a integre 9 x 10 puissance 10 rads gamma et 6 x 10 puissance 18 neutrons rapides). La troisieme partie est consacree a l'etude des qualites de l'appareil: robustesse, fidelite, precision, sensibilite, gamme de mesure. Enfin dans la derniere partie sont decrites deux applications de la methode calorimetrique a la mesure du depot d'energie dans un acier special et dans l'eau. (auteurs)

  2. Les Cahiers du CREAD

    African Journals Online (AJOL)

    Admin

    politique de bas prix exercée par la Russie et le Qatar vient confirmer ce constat ; s'ajoute à cela l'entrée éventuelle du gaz non conven- tionnel, dont son prix actuel de 3/4 $US, offre aux USA l'opportunité d'être exportateur de ..... les compagnies à produire en matière du gaz naturel, tels le prix du gaz naturel, le prix des ...

  3. Bulletin du CRDI #124

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les femmes jouent un rôle important dans les exploitations minières artisanales et à petite échelle en Afrique subsaharienne. De concert ... Couverture du livre: Une vie saine pour les femmes et les enfants vulnérables · Couverture du livre: Entre el activismo y la intervención · Couverture du livre: Revitalizing Health for All.

  4. Bulletin du CRDI #125

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'IOSRS remporte le prix de la diplomatie scientifique · GrowInclusive : la plateforme tant attendue est en construction · Toutes les nouvelles. Activités à venir. Semaine du développement international 2018. Le CRDI célébrera la Semaine du développement international du 4 au 10 février 2018. Suivez-nous sur Twitter et ...

  5. Thermodynamic consistency of vapor pressure and calorimetric data for argon, krypton, and xenon

    International Nuclear Information System (INIS)

    Schwalbe, L.A.; Crawford, R.K.; Chen, H.H.; Aziz, R.A.

    1977-01-01

    A new two-parameter vapor pressure equation has been derived which, unlike the Salter equation, is shown to be equally applicable to quantum or classical solids and even liquids. The condensed phase enthalpies and entropies are given directly by the fitted parameters with accuracies comparable to those which have been claimed for existing independent calorimetric measurements. Recent vapor pressure data for the solid and liquid phases of argon, krypton, and xenon are analyzed in this manner, and the results are compared with the available calorimetric data. New values for the cohesive energy at T=0 are also derived for these substances

  6. Instrumentation calibration

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-08-01

    Procedures for the calibration of different types of laboratory equipment are described. Provisions for maintaining the integrity of reference and working standards traceable back to a national standard are discussed. Methods of validation and certification methods are included. An appendix lists available publications and services of national standardizing agencies

  7. High dose calibrations at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    McDonald, J.C.; Fox, R.A.

    1988-10-01

    The need is increasing for both high radiation exposures and calibration measurements that provide traceability of such exposures to national standards. The applications of high exposures include: electronic component damage studies, sterilization of medical products and food irradiation. Accurate high exposure measurements are difficult to obtain and cannot, in general, be carried out with a single dose measurement system or technique because of the wide range of doses and the variety of materials involved. This paper describes the dosimetric measurement and calibration techniques used at the Pacific Northwest Laboratory (PNL) that make use of radiochromic dye films, thermoluminescent dosimeters (TLDs), ionization chambers, and calorimetric dosimeters. The methods used to demonstrate the consistency of PNL calibrations with national standards will also be discussed. 4 refs

  8. Analysis of thermal power calibration method

    International Nuclear Information System (INIS)

    Zagar, T.; Ravnik, M.; Persic, A.

    2000-01-01

    The methods for determining fuel element burnup have recently become interesting because of activities related to the shipment of highly enriched fuel elements back to the United States for final disposal before 2009. The most common and practical method for determining fuel element burnup in research reactors is reactor calculation. Experience has shown that burnup calculations become complicated and biased with uncertainties if a long period of reactor operation must be reproduced. Besides this, accuracy of calculated burnup is always limited with accuracy of reactor power calibration, since burnup calculation is based on calculated power density distribution, which is usually expressed in terms of power released per fuel element and normalised to the reactor power It is obvious that reactor thermal power calibration is very important for precise fuel element burnup calculation. Calculated fuel element burnup is linearly dependent on the thermal reactor power. The reactor power level may be determined from measured absolute thermal flux distribution across the core in the horizontal and vertical planes. Flux distributions are measured with activation of cadmium covered and bare foils irradiated by the steady reactor power. But it should be realised that this method is time consuming and not accurate. This method is practical only for zero power reactors and is in practice very seldom performed for other reactors (e.g. for TRIGA reactor in Ljubljana absolute thermal flux distribution was not performed since reactor reconstruction in 1991). In case of power reactors and research reactors in which a temperature rise across the core is produced and measured than a heat balance method is the most common and accurate method of determining the power output of the core. The purpose of this paper is to analyse the accuracy of calorimetric reactor power calibration method and to analyse the influence of control rod position on nuclear detector reading for TRIGA reactors

  9. "Cirque du Freak."

    Science.gov (United States)

    Rivett, Miriam

    2002-01-01

    Considers the marketing strategies that underpin the success of the "Cirque du Freak" series. Describes how "Cirque du Freak" is an account of events in the life of schoolboy Darren Shan. Notes that it is another reworking of the vampire narrative, a sub-genre of horror writing that has proved highly popular with both adult and…

  10. Calorimetric method for current sharing temperature measurements in ITER conductor samples in SULTAN

    International Nuclear Information System (INIS)

    Bagnasco, M.

    2009-01-01

    Several Toroidal Field Conductor short samples with slight layout variations have been assembled and tested in the SULTAN facility at CRPP. The measurement campaigns started in 2007 and are still ongoing. The performance of every conductor is expressed in terms of current sharing temperature (T cs ), i.e. the temperature at which a defined electric field, 10 μV/m, is detected in the cable due to the incipient superconducting-to-normal state transition. The T cs at specific operating conditions is the key design parameter for the ITER conductors and is the main object of the qualification tests. Typically, the average electric field is measured with voltage tap pairs attached on the jacket along the conductor. The inability however to explain observed premature voltage developments opened the discussion about possible alternative measuring methods. The He flow calorimetric method is based on the measurement of the resistive power generation in the conductor. It relies on the detection of very small temperature increases along the conductor in steady state operation. The accuracy and the reliability of the calorimetric method in SULTAN are critically discussed, with particular emphasis on the instrumentation requirements and test procedures. The application of the calorimetric method to the recent SULTAN test campaigns is described with its merits and limits. For future tests of ITER conductors in SULTAN, the calorimetric method for T cs test is proposed as a routine procedure.

  11. A calorimetric study of solute effects on the kinetic stability of a-amylase

    DEFF Research Database (Denmark)

    Olsen, Søren Nymand; Andersen, Kim Bruno; Øgendal, Lars Holm

    2009-01-01

    In this study we evaluated the applications of isothermal titration calorimetry (ITC) to Study solute effects on the kinetics of irreversible protein denaturation. More specifically, denaturation of Bacillus Halmapalus alpha-amylase (BHA) was initiated by addition of EDTA to the calorimetric cell...

  12. Ecologie du phytoplancton du lac Kivu

    Directory of Open Access Journals (Sweden)

    Sarmento, H.

    2008-01-01

    Full Text Available Speciation within the African Coffee Pathogen. Cet article analyse s'il est avantageux d'utiliser le compost au lieu de l'engrais minéral pour produire la laitue dans la zone urbaine et péri-urbaine de Yaoundé. Les résultats de terrain montrent l'obtention de rendements et profits plus élevés lorsqu'on utilise le compost. Les résultats de la fonction de production Cobb-Douglas prouvent que l'utilisation du compost est statistiquement significative pour expliquer la variation de rendement de la laitue et que le compost est l'intrant le plus productif. D'autres résultats montrent que le compost fournit la matière organique utile au sol et que les besoins d'irrigation en eau de la culture sont réduits grâce à l'utilisation du compost. Par conséquent, malgré le fait que l'application du compost demande une main-d'oeuvre beaucoup plus élevée, son utilisation est généralement bénéfique pour les agriculteurs vivant aux alentours de Yaoundé. Les programmes de vulgarisation de cet intrant pour encourager son adoption devraient donc figurer parmi les points prioritaires dans la politique agricole du gouvernement camerounais.

  13. Empirical Calibration for Dolomite Stoichiometry Calculation: Application on Triassic Muschelkalk- Lettenkohle Carbonates (French Jura Calibration empirique pour le calcul de la stoechiométrie de la dolomite : application aux carbonates triasiques du Muschelkalk-Lettenkohle (Jura français

    Directory of Open Access Journals (Sweden)

    Turpin M.

    2012-02-01

    équation de Lumsden et de méthodes antérieures. L’approche proposée est vérifiée grâce à l’analyse d’un échantillon référence de dolomite (Eugui et appliquée à des roches carbonatées du Trias (Muschelkalk supérieur-Lettenkohle du Jura français. Elle est combinée à une étude pétrographique et isotopique et peut être appliquée tant aux roches qu’aux ciments dolomitiques. Les dolomies du Muschelkalk supérieur se sont formées au cours d’une dolomitisation d’enfouissement associée à des fluides dont la température augmente et ayant une composition isotopique variable au cours de l’enfouissement. Outre la pétrographie, ceci est également mis en évidence par le pourcentage de Ca calculé dans les dolomites, qui atteint progressivement une stoechiométrie idéale (de 53,16 % à 51,19 % parallèlement au développement de la dolomitisation. Les dolomites du Lettenkohle montrent une stoechiométrie proche d’une stoechiométrie idéale (51,06 % Ca, sont ordonnées et associées à de l’anhydrite. Leur formation est liée à deux étapes de dolomitisation : de type sabkha et d’enfouissement. Cette étude permet ainsi une meilleure caractérisation des différents types de dolomites dans les roches sédimentaires et par conséquent une meilleure détermination de leur potentiel en tant que réservoir.

  14. Du Pont de Nemours

    NARCIS (Netherlands)

    Ros JPM; LAE

    1994-01-01

    Dit rapport over Du Pont de Nemours (produktie van o.a. chemische stoffen) is gepubliceerd binnen het Samenwerkingsproject Procesbeschrijvingen Industrie Nederland (SPIN). In het kader van dit project is informatie verzameld over industriele bedrijven of industriele processen ter ondersteuning

  15. TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac

    Energy Technology Data Exchange (ETDEWEB)

    Prez, L de; Pooter, J de; Jansen, B [VSL, Delft (Netherlands); Wolthaus, J; Asselen, B van; Woodings, S; Soest, T; Kok, J; Raaymakers, B [University Medical Center Utrecht, Utrecht (Netherlands)

    2016-06-15

    Purpose: Reference dosimetry in MR-guided radiotherapy is performed in the presence of a B-field. As a consequence the response of ionization chambers changes considerably and depends on parameters not considered in traditional reference dosimetry. Therefore future Codes of Practices need ionization chamber correction factors to correct for both the change in beam quality and the presence of a B-field. The objective was to study the feasibility of water calorimetric absorbed-dose measurements in a 1.5 T B-field of an MRLinac and the direct measurement of kQ,B calibration of ionization chambers. Methods: Calorimetric absorbed dose to water Dw was measured with a new water calorimeter in the bore of an MRLinac (TPR20,10 of 0.702). Two waterproof ionization chambers (PTW 30013, IBA FC-65G) were calibrated inside the calorimeter phantom (ND,w,Q,B). Both measurements were normalized to a monitor ionization chamber. Ionization chamber measurements were corrected for conventional influence parameter. Based on the chambers’ Co-60 calibrations (ND,w,Q0), measured directly against the calorimeter. In this study the correction factors kQ,B was determined as the ratio of the calibration coefficients in the MRLinac and in Co-60. Additionally, kB was determined based on kQ values obtained with the IAEA TRS-398 Code of Practice. Results: The kQ,B factors of the ionization chambers mentioned above were respectively 0.9488(8) and 0.9445(8) with resulting kB factors of 0.961(13) and 0.952(13) with standard uncertainties on the least significant digit(s) between brackets. Conclusion: Calorimetric Dw measurements and calibration of waterproof ionization chambers were successfully carried out in the 1.5 T B-field of an MRLinac with a standard uncertainty of 0.7%. Preliminary kQ,B and kB factors were determined with standard uncertainties of respectively 0.8% and 1.3%. The kQ,B agrees with an alternative method within 0.4%. The feasibility of water calorimetry in the presence of B

  16. Les Cahiers du CREAD

    African Journals Online (AJOL)

    Admin

    6 juil. 2007 ... La problématique du développement du secteur de l'artisanat en. Algérie a été très peu abordée par les chercheurs, qu'ils soient universitaires ou .... La loi a institué une taxe d'apprentissage dont le taux a été fixé à. 1% de la ...

  17. Les outils du CERN

    CERN Multimedia

    1999-01-01

    C'est le plus grand centre mondial de recherche en physique des particules. Les outils du Laboratoire, accélérateurs et détecteurs de particules, figurent parmi les instruments scientifiques les plus complexes au monde. Des prix Nobels ont d'ailleurs été attribués aux physiciens du CERN pour leurs développements.

  18. Bulletin du CRDI #127

    International Development Research Centre (IDRC) Digital Library (Canada)

    La mise à l'échelle de la recherche et de l'innovation en vue de créer un impact social constitue une priorité pour la communauté du développement. Toutefois ... Nous avons renouvelé notre soutien à la recherche auprès du gouvernement de l'Inde ... Des femmes étudient à l'École supérieure d'infotronique d'Haïti.

  19. Liquid-gas and solid-liquid interface: thermodynamics of capillary condensation application to a prosimetry by calorimetric measurements

    International Nuclear Information System (INIS)

    Derrien, Francois; Hartmanshenn, Olivier.

    1978-01-01

    A direct determination of the pore radii distribution is proposed using calorimetric measurements during condensation and evacuation of pores by capillary condensate. This method is independant of any gravimetric or volumetric measurement of adsorption

  20. Construction of the ATLAS end cap electromagnetic calorimeter and study of its performances; Construction du bouchon du calorimetre electromagnetique d'ATLAS et etudes de ses performances

    Energy Technology Data Exchange (ETDEWEB)

    Barrillon, P

    2002-09-01

    ATLAS is one of the four experiments which will take place at the LHC, the CERN future protons collider. This accelerator, which should start in 2007, will allow to continue the studies carried out by its predecessors, as the standard model Higgs boson and new physics searches. The very high luminosity -10 fb{sup -1} during the first three functioning years, then 100 fb{sup -1}- and the 14 TeV in the frame center will ease these studies. The Centre de Physique des Particules de Marseille took part in the ATLAS collaboration, taking in charge half of the End-cap electromagnetic calorimeter modules construction. The description of this sub-detector and the construction steps, in particular the electrical tests which allow the stacking validation, are presented in this document. These tests results, obtained for the live first production modules, are analysed. The pre-series module (module 0) performances, obtained with beam tests performed at CERN in 1999, are also presented. The detector uniformity studies have allowed to perform important improvements on the calorimeter components. A 0.6% global constant term has been determined in the End-cap internal region (wheel). (author)

  1. Mise en service du calorimetre electromagnetique d'Atlas et determination du potentiel de decouverte d'un Z' --> e+e- dans les premieres donnees LHC

    CERN Document Server

    Mangeard, Pierre-Simon

    2009-01-01

    After about fifteen years of development, the ATLAS detector is ready to operate and recorded, in 2008, several millions of cosmic events as well as first LHC data. This achievement is based on the long experience of beam tests and on the large effort towards the detector in situ commissioning undertaken by the ATLAS collaboration. This promises fast ability to perform searches for evidence of Higgs boson and new physics. I heavily contributed to the in situ commissioning of the EM calorimeter. To verify its performance, I studied the first cosmic data taken in 2006 which allowed the first in situ analysis of dead channels, energy reconstruction and detector response uniformity. This participation to the commissioning has continued with the study of the single beam data recorded during the first week of LHC operation (Sept. 2008). Expanding on my expertise of the EM calorimeter, I focused my physics analysis, prepared with simulation, on the promising discovery potential of new physics at LHC via the di-elect...

  2. Non-Calorimetric Determination of the Adsorption Heat of Volatile Organic Compounds under Dynamic Conditions

    Directory of Open Access Journals (Sweden)

    Abdelhamid Korrir

    2015-04-01

    Full Text Available Avoiding strong chemical bonding, as indicated by lower heat of adsorption value, is among the selection criteria for Volatile Organic Compounds adsorbents. In this work, we highlight a non-calorimetric approach to estimating the energy of adsorption and desorption based on measurement of involved amounts, under dynamic conditions, with gaseous Fourier Transform Infrared spectroscopy. The collected data were used for obtaining adsorption heat values through the application of three different methods, namely, isosteric, temperature programmed desorption (TPD, and temperature-programmed adsorption equilibrium (TPAE. The resulting values were compared and discussed with the scope of turning determination of the heat of adsorption with non-calorimetric methods into a relevant decision making tool for designing cost-effective and safe operating of adsorption facilities.

  3. Calorimetric thermal-vacuum performance characterization of the BAe 80K space cryocooler

    International Nuclear Information System (INIS)

    Kotsubo, V.Y.; Johnson, D.L.; Ross, R.G. Jr.

    1992-01-01

    This paper on a comprehensive characterization program which is underway at JPL to generate test data on long-life, miniature Stirling-cycle cryocoolers for space application. The key focus of this paper is on the thermal performance of the British Aerospace (BAe) 80K split-Stirling-cycle cryocooler as measured in a unique calorimetric thermal-vacuum test chamber that accurately simulates the heat-transfer interfaces of space. Two separate cooling fluid loops provide precis individual control of the compressor and displacer heatsink temperatures. In addition, heatflow transducers enable calorimetric measurements of the heat rejected separately by the compressor and displacer. Cooler thermal performance has been mapped for coldtip temperatures ranging from below 45 K to above 150 K, for heat-sink temperatures ranging from 280 K to 320 K, and for a wide variety of operational variables including compressor-displacer phase, compressor-displacer stoke, drive frequency, and piston-displacer dc offset

  4. Calibration of the calorimeter of the ATLAS muon cosmic

    International Nuclear Information System (INIS)

    Federic, P.

    2006-01-01

    This summer is for the ATLAS experiment at CERN scheduled calibration with cosmic muons ECC. It is one of the standard methods of calibrating calorimeters. Before these measurements it is necessary to perform precise Monte Carlo simulation, which is essential to a detailed understanding of the physics of the processes. Based on the known data on the spectra of cosmic muons, such as the frequency (flux) or the energy spectrum can be achieved highly accurate results. So far were simulated 3 samples for max. muon angle of incidence 45, 60 and 75 degrees, each containing 1 M events. Based on this we found the first necessary data and in particular, they allow us to determine the best angle for the ratio of the number of muons generated a number of events in the calorimetric system. (author)

  5. Study of the sensibility of the Antares neutrino telescope to very high energy photons: Contribution to the time calibration of the detector; Etude de la sensibilite du telescope a neutrinos Antares aux photons de tres haute energie: Contribution a l'etalonnage en temps du detecteur

    Energy Technology Data Exchange (ETDEWEB)

    Guillard, G.

    2010-10-15

    From the sea-floor, the 900-odd photomultiplier tubes of the Antares neutrino telescope scrutinize the abysses attempting to discern, amid bioluminescence and marine radioactivity, Cerenkov photons emitted by muons from astrophysical neutrinos, and to distinguish these muons from those generated by air showers produced by cosmic rays. Antares has been collecting data since 2006; this feat of engineering has paved the way for submarine neutrino astronomy: Antares is expected to be the forerunner of a larger instrument, KM3NeT. Telescope's performance is characterized in part by its angular resolution. In the case of Antares, the angular resolution is directly related to the time resolution of the detector's elements. This manuscript presents a correction for one of the main sources of deterioration of this time resolution, the walk effect induced by the set up of a fixed threshold for triggering the photomultiplier tubes signal. This correction, implemented in the official software chain of the Antares collaboration, improves in particular the events reconstruction quality estimator. This implementation allows further optimizations. The author also attempts to evaluate, using a complete Monte-Carlo simulation, the possibility of using very high energy photon sources as calibrated muon beams in order to estimate the absolute pointing and the angular resolution of the telescope. Although limited by large uncertainties, it is demonstrated that the possibility to detect such sources is extremely small. In addition, it is shown that the atmospheric neutrino background induced by very high-energy photons is negligible. (author)

  6. Accounting for apparent deviations between calorimetric and van't Hoff enthalpies.

    Science.gov (United States)

    Kantonen, Samuel A; Henriksen, Niel M; Gilson, Michael K

    2018-03-01

    In theory, binding enthalpies directly obtained from calorimetry (such as ITC) and the temperature dependence of the binding free energy (van't Hoff method) should agree. However, previous studies have often found them to be discrepant. Experimental binding enthalpies (both calorimetric and van't Hoff) are obtained for two host-guest pairs using ITC, and the discrepancy between the two enthalpies is examined. Modeling of artificial ITC data is also used to examine how different sources of error propagate to both types of binding enthalpies. For the host-guest pairs examined here, good agreement, to within about 0.4kcal/mol, is obtained between the two enthalpies. Additionally, using artificial data, we find that different sources of error propagate to either enthalpy uniquely, with concentration error and heat error propagating primarily to calorimetric and van't Hoff enthalpies, respectively. With modern calorimeters, good agreement between van't Hoff and calorimetric enthalpies should be achievable, barring issues due to non-ideality or unanticipated measurement pathologies. Indeed, disagreement between the two can serve as a flag for error-prone datasets. A review of the underlying theory supports the expectation that these two quantities should be in agreement. We address and arguably resolve long-standing questions regarding the relationship between calorimetric and van't Hoff enthalpies. In addition, we show that comparison of these two quantities can be used as an internal consistency check of a calorimetry study. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Determination of the protonation enthalpy of humic acid by calorimetric titration technique

    International Nuclear Information System (INIS)

    Kimuro, Shingo; Kirishima, Akira; Sato, Nobuaki

    2015-01-01

    Graphical abstract: The thermodynamic quantities of protonation of humic acid were determined by the combination of potentiometric titration and calorimetric titration. It was observed that the protonation enthalpy and Gibbs free energy had been affected by pH of solution. As a result, the thermodynamics of the protonation reaction of humic acid is influenced by the polyelectrolyte effect and the heterogeneity. - Highlights: • We applied calorimetric titration technique to the protonation of humic acid. • The thermodynamic quantities of protonation of humic acid were determined. • The protonation enthalpy of humic acid is affected by the heterogeneity. • Gibbs free energy of the protonation is affected by the polyelectrolyte effect. - Abstract: In this study, the calorimetric titration technique was used to determine the protonation enthalpy of two reference humic acids and polyacrylic acid. First, we obtained the apparent protonation constant of two kinds of humic acid purchased from IHSS (International Humic Substances Society) and polyacrylic acid by potentiometric titration. Second, we obtained the protonation enthalpy of them by calorimetric titration. The protonation enthalpy of humic acid was affected by pH and the ionic strength of bulk solution. From the comparison of ΔH between humic acid and polyacrylic acid, it was concluded that the pH dependence of ΔH is attributed to the heterogeneity of humic acid. And ΔH of phenolic hydroxyl group in humic acid is strongly influenced by the electric double layer of humic acid’s surface. This is considered to be a reason of the ionic strength dependence of ΔH. On the other hand, Gibbs free energy of the protonation of humic acid is affected by the electrostatic attraction with the progress of dissociation of functional groups such as carboxyl group and phenolic hydroxyl group. Consequently, the thermodynamics of the protonation of humic acid is affected by the polyelectrolyte effect and the

  8. Vibrational, calorimetric and nonlinear optical studies of melaminium-bis(trichloroacetate) monohydrate molecular ionic crystal

    Science.gov (United States)

    Debrus, S.; Marchewka, M. K.; Drozd, M.; Ratajczak, H.

    2007-04-01

    The efficiency of second harmonic generation for melaminium bis(trichloroacetate) was estimated relatively to KDP: deff = 3.09 deff (KDP). Room temperature FT IR and FT Raman spectra were recorded. Some spectral features of this new crystal are referred to corresponding one for melamine crystal as well as for other trichloroacetates. Differential scanning calorimetric measurements performed on powder sample indicate the phase transition point at approximately 276 and 239 K for heating and cooling, respectively.

  9. The design of a calorimetric standard of ionising radiation absorbed dose

    International Nuclear Information System (INIS)

    Huntley, R.B.

    1981-05-01

    The design of a calorimetric working standard of ionising radiation absorbed dose is discussed. A brief history of the appropriate quantities and units of measurement is given. Detailed design considerations follow a summary of the relevant literature. The methods to be used to relate results to national standards of measurement are indicated, including the need for various correction factors. A status report is given on the construction and testing program

  10. First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho

    CERN Document Server

    Ranitzsch, P. C. -O.; Wegner, M.; Kempf, S.; Fleischmann, A.; Enss, C.; Gastaldo, L.; Herlert, A.; Johnston, K.

    2014-01-01

    The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum. We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber. We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we dis...

  11. Development of a calorimetric system for electron beam dosimetry in radiation processing; Desenvolvimento de um sistema calorimetrico para dosimetria de feixe de eletrons em processos por radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Banados P, H E

    1994-12-31

    A calorimetric system for electron beam dosimetry in radiation processing was developed. The system is composed of a graphite core calorimeter, the temperature measuring and electrical calibrating instrumentation, a microcomputer and the software for the system automation. The research aimed at the optimization of the project parameters, the development of advanced methodologies for calibrating the temperature sensor, the determination of the thermal capacity as a function of the temperature, the measurement of the absorbed dose, and the development of the software needed for the system operation. The operating range extends from 0.1 kGy to 30 kGy. The uncertainty in the measurement of the absorbed dose was estimated to be {+-} 1.8% at the 95% confidence level. Comparative tests of the absorbed dose measurements were made using the IPEN electron accelerator. The results obtained showed an excellent agreement between the absorbed dose determined by the calorimeter and the absorbed dose calculated from the nominal power delivered by the accelerator. (author). 67 refs, 63 figs, 2 tabs.

  12. Effet du Pediococcus acidilactici sur le bilan lipidique sanguin du ...

    African Journals Online (AJOL)

    Les résultats relatifs aux performances zootechniques ont montré que l'addition du probiotique a amélioré significativement le gain de poids pendant la phase de croissance se traduisant par un indice de consommation meilleur. Les dosages du cholestérol total, des triglycérides, du HDL et du LDL ont été déterminés à la ...

  13. Top pairs production and effects of new physics. Jet calibration with W into jet-jet process. Top mass measurement; Production de paires de Top et effet de Nouvelle Physique. Calibration des jets avec le processus Wen en jet-jet. Mesure de la masse du Top

    Energy Technology Data Exchange (ETDEWEB)

    Cogneras, E

    2007-06-15

    Since it was discovered in 1995 at Fermilab, the top quark is the subject of a great attention. It completes the third quark generation of the standard model of particle physics, and the measurement of its properties constrains strongly this model. It is also a preferential way to probe new physics expected around 1 TeV. This thesis, performed using the Atlas detector at LHC, describes the methods implemented in order to measure precisely the top quark mass in the lepton + jets channel. Several analysis ways are presented in function of the performances of the detector, especially its capacity to identify the b jets. The precise measurement of the top quark mass needs a deep understanding of the jet energy scale. This thesis suggests a strategy to calibrate the light jets using the constraint on the W boson mass, and shows that a precision of 1 GeV{sup 2}/c{sup 2} on the top mass measurement is achievable. An evaluation of the discovery potential of tt-bar resonances, foreseen by models beyond the standard model is also carried out. (author)

  14. Calorimetric sensitivity and thermal resolution of a novel miniaturized ceramic DSC chip in LTCC technology

    Energy Technology Data Exchange (ETDEWEB)

    Missal, Wjatscheslaw, E-mail: wmissal@gmx.net [Department of Functional Materials, University of Bayreuth, 95440 Bayreuth (Germany); Kita, Jaroslaw [Department of Functional Materials, University of Bayreuth, 95440 Bayreuth (Germany); Wappler, Eberhard [wsk Mess- und Datentechnik GmbH, Gueterbahnhofstr. 1, 63450 Hanau (Germany); Bechtold, Franz [VIA electronic GmbH, Robert-Friese-Str. 3, 07629 Hermsdorf (Germany); Moos, Ralf [Department of Functional Materials, University of Bayreuth, 95440 Bayreuth (Germany)

    2012-09-10

    Highlights: Black-Right-Pointing-Pointer Unique vertical design of a DSC device manufactured in the low-cost LTCC technology and therefore capable of one-way use. Black-Right-Pointing-Pointer Fully functional DSC device with a size of only 1.5 mm Multiplication-Sign 11 mm Multiplication-Sign 39 mm enabling very low power consumption. Black-Right-Pointing-Pointer Comparable measurement performance as conventional DSC whilst also suitable for mobile thermal analysis. Black-Right-Pointing-Pointer Thermal resolution is 0.12 (TAWN test). Repeatability of the peak area is within 0.3% for indium samples. Black-Right-Pointing-Pointer Calorimetric sensitivity: linear with regard to temperature and independent from sample mass and heating rate in wide ranges. - Abstract: The calorimetric properties of a novel miniaturized ceramic differential scanning calorimeter device (MC-DSC) with integrated heater and crucible are presented. All features of a conventional DSC apparatus (including oven) are integrated into this DSC device of the size 11 mm Multiplication-Sign 39 mm Multiplication-Sign 1.5 mm. The MC-DSC device is suitable for one-way use, since it is fully manufactured in the low-cost planar low temperature co-fired ceramics technology. First characterization of this device is performed using indium, tin and zinc samples. The calorimetric sensitivity at 156.6 Degree-Sign C is 0.24 J/ Degree-Sign C s. It depends linearly on temperature in the range of at least 150 Degree-Sign C and 420 Degree-Sign C. The calorimetric sensitivity is constant up to an enthalpy of fusion of at least {Delta}H = 750 mJ (at 156.6 Degree-Sign C). The thermal analysis of indium in direct contact to the crucible of the chip even reveals a constant calorimetric sensitivity up to an enthalpy of fusion of at least {Delta}H = 1000 mJ. The repeatability of the peak area is within {+-}0.3% (11 mg indium, 10 measurements). The thermal resolution determined using 4,4 Prime -azoxyanisole under TAWN test

  15. Les mots du jazz

    OpenAIRE

    Roueff, Olivier

    2007-01-01

    L’ouvrage d’André Schaeffner constitue la première analyse savante du jazz (1926). Il a marqué une étape importante dans le processus de réinvention du jazz en France en contribuant notamment, par sa réception et les polémiques qu’il a suscitées, à transformer l’identification du jazz d’une musique « américaine » à une musique « noire-américaine » (c’est-à-dire aux « racines » africaines). Les analyses proposées dans cet ouvrage, alors qu’elles désignaient des musiques que la critique de jazz...

  16. Study of the aging processes in polyurethane adhesives using thermal treatment and differential calorimetric, dielectric, and mechanical techniques ; 1, identifying the aging processes ; 2, quantifying the aging effect

    CERN Document Server

    Althouse, L P

    1979-01-01

    Study of the aging processes in polyurethane adhesives using thermal treatment and differential calorimetric, dielectric, and mechanical techniques ; 1, identifying the aging processes ; 2, quantifying the aging effect

  17. fibrosarcome du larynx

    African Journals Online (AJOL)

    pie du lit tumoral est employée comme complément thé- rapeutique [9] alors que la chimiothérapie est générale- ment indiquée dans les formes métastatiques. Le pronos- tic dépend essentiellement du degré de différentiation his- tologique. En fait, le fibrosarcome bien différencié est caractérisé par la fréquence de récidive ...

  18. du Chott Marouane

    African Journals Online (AJOL)

    plancton de 90 µm de vide de maille. Ils ont été conservés dans du formol à 5%. L'identification de l'espèce est basée sur des critères morphologiques [20]: la forme des furcas, les lobes frontaux des antennes des mâles, de l'organe copulateur (pénis) et du sac ovigère. Le comptage des soies furcales a été réalisé. L'étude ...

  19. les cahiers du cread

    African Journals Online (AJOL)

    Our Journal “les cahiers du cread” is a quarterly economic review publishing original findings of empirical research and theoretical debates on fields pertaining to our mission coverage (Macro Economics, Industrial Economics and Firms, Human Development & Social Economics, Agriculture & Environment). Other websites ...

  20. Adiabatic calorimeter with static vacuum for the measurement of the heating of in- pile materials; Calorimetre adiabatique a vide statique pour la mesure d'echauffements de materiaux en pile

    Energy Technology Data Exchange (ETDEWEB)

    Brun, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    After having reviewed the various interaction processes occurring between radiations present in nuclear reactors and matter, the author describes the different calorimetric methods which may be used for measuring the energy absorbed in the materials. He then gives a detailed description of the adiabatic calorimeter, the associated measurement device and the calibration methods which have been chosen. He finally gives values for the heating produced at various experimental positions in the reactors EL-2 and EL-3 for several materials currently used in reactor construction. (author) [French] Apres avoir passe en revue les differents processus d'interaction des rayonnements, existant dans les reacteurs nucleaires, avec la matiere, l'auteur decrit les differentes methodes calorimetriques qui peuvent etre utilisees pour mesurer l'energie absorbee dans les materiaux. II presente ensuite en detail le calorimetre adiabatique, le dispositif de mesure associe et les methodes d'etalonnage qui ont ete retenus. Enfin il donne des valeurs d'echauffement dans divers emplacements experimentaux des piles EL-2 et EL-3 pour differents materiaux d'utilisation courante dans les reacteurs. (auteur)

  1. Some examples of a differential calorimeter use for low temperature thermal effects measurement; Quelques exemples d'utilisation d'un calorimetre differentiel a puissance compensee pour des mesures d'anomalies thermiques a basses temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Bochirol, L; Bonjour, E

    1967-07-01

    The principle of a differential calorimeter is briefly described. The apparatus allows a direct and continuous determination of the differential heat-capacity between a sample and a reference, in the range 20 to 600 deg. K approximately. Some examples concerning measurements at low temperatures of reversible or non reversible thermal effects are given. They show the possibilities of the apparatus and are connected with: - detection and measurements of thermal effects associated to structural transformations in elastomers at low temperatures, - measurements of Wigner energy released after neutron irradiations at 77 deg. K for: recrystallized pyro-graphites; high purity iron, aluminium. [French] On decrit brievement le principe d'un calorimetre differentiel qui permet la determination directe et continue de la difference de chaleur specifique apparente entre un echantillon et une reference, dans une gamme de temperatures s'etendant de 20 a 600 deg. K environ. On donne quelques exemples de mesure a basses temperatures d'effets thermiques reversibles ou non reversibles. Ils montrent les possibilites de l'appareillage et concernent: - la detection et la mesure d'effets thermiques associes a des transformations structurales dans des elastomeres a basse temperature, - la mesure du degagement d'energie Wigner apres des irradiations neutroniques a 77 deg. K dans: des pyrographites recristallises; du fer de haute purete et de l'aluminium. (auteurs)

  2. A calorimetric particle detector using an iridium superconducting phase transition thermometer

    International Nuclear Information System (INIS)

    Frank, M.; Dummer, D.; Cooper, S.; Igalson, J.; Proebst, F.; Seidel, W.

    1994-01-01

    We report on a calorimetric particles detector consisting of an 18.3 g silicon crystal and an iridium superconducting phase transition thermometer. The cryogenic calorimeter and the associated apparatus are described in detail. The pulses from irradiation with an α-particle source have a large unexpected overshoot in addition to the component expected from a naive thermal model. The pulse height spectrum displays an energy resolution of 1 percent FWHM at 6 MeV and good linearity. The noise, electrothermal feedback, and position dependence are discussed. (orig.)

  3. Calorimetric Measurement for Internal Conversion Efficiency of Photovoltaic Cells/Modules Based on Electrical Substitution Method

    Science.gov (United States)

    Saito, Terubumi; Tatsuta, Muneaki; Abe, Yamato; Takesawa, Minato

    2018-02-01

    We have succeeded in the direct measurement for solar cell/module internal conversion efficiency based on a calorimetric method or electrical substitution method by which the absorbed radiant power is determined by replacing the heat absorbed in the cell/module with the electrical power. The technique is advantageous in that the reflectance and transmittance measurements, which are required in the conventional methods, are not necessary. Also, the internal quantum efficiency can be derived from conversion efficiencies by using the average photon energy. Agreements of the measured data with the values estimated from the nominal values support the validity of this technique.

  4. The interaction of new piroxicam analogues with lipid bilayers--a calorimetric and fluorescence spectroscopic study.

    Science.gov (United States)

    Maniewska, Jadwiga; Szczęśniak-Sięga, Berenika; Poła, Andrzej; Sroda-Pomianek, Kamila; Malinka, Wiesław; Michalak, Krystyna

    2014-01-01

    The purpose of the present paper was to assess the ability of new piroxicam analogues to interact with the lipid bilayers. The results of calorimetric and fluorescence spectroscopic experiments of two new synthesized analogues of piroxicam, named PR17 and PR18 on the phase behavior of phospholipid bilayers and fluorescence quenching of fluorescent probes (Laurdan and Prodan), which molecular location within membranes is known with certainty, are shown in present work. The presented results revealed that, depending on the details of chemical structure, the studied compounds penetrated the lipid bilayers.

  5. Calorimetric systems designed for in-field nondestructive assay of plutonium-bearing materials

    International Nuclear Information System (INIS)

    Roche, C.T.; Perry, R.B.; Lewis, R.N.; Jung, E.A.; Haumann, J.R.

    1978-01-01

    Conventional calorimetric design measures the temperature rise of a plutonium-containing sample chamber in contact with a large water-bath heat sink. This design lacks the mobility needed by inspection personnel. The Argonne National Laboratory air-chamber isothermal calorimeters are low-thermal capacitance devices which eliminate the need for large, constant-temperature heat sinks. A bulk calorimeter designed to measure sealed containers holding up to 3 kg Pu, and a small-sample calorimeter designed to measure mixed-oxide fuel pellets and powders are discussed. The operational characteristics of these instruments are described, and the results of sample assays are presented

  6. Comparaison du filtre adaptatif RIF et du filtre a base de reseau de ...

    African Journals Online (AJOL)

    Comparaison du filtre adaptatif RIF et du filtre a base de reseau de neurones pour le filtrage du courant de reference pour la commande du filtre actif parallele. C Benachaiba, A Bassou, B Mazari ...

  7. Le ministre du Commerce international du Canada rencontre des ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    17 juil. 2017 ... La promotion de l'entrepreneuriat, la façon dont le commerce peut profiter aux femmes et à leur famille, et la création d'emplois pour les plus vulnérables étaient au coeur de la discussion en table ronde du ministre du Commerce international du Canada, l'honorable François-Philippe Champagne, et des ...

  8. Portage vaginal du streptocoque du groupe B chez la femme ...

    African Journals Online (AJOL)

    Introduction: le streptocoque du groupe B est le principal agent impliqué dans les infections materno-fœtales, les septicémies et les méningites du nouveau-né à terme. L'objectif est de déterminer le taux de portage maternel du streptocoque du groupe B (SGB) à terme. Méthodes: un prélèvement vaginal a été réalisé de ...

  9. Aux origines du monde

    CERN Multimedia

    2004-01-01

    "C'est l'histoire d'une aventure humaine, scientifique, international qui a vu le jour il y a cinquante ans, aux confins de la Suisse et du département de l'Ain. Le plus grand laboratoire de physique des particules du monde, le Cern, a été fondé en 1954. Les festivités organisées à l occasion de cet anniversaire connaîtront leur point d'orgue le 16 octobre prochain, avec portes-ouvertes, accueil de personallités et inauguration d'un monumnet spécifique, le Globe de l'innovation" (2 pages)

  10. CHOEUR DU CERN

    CERN Multimedia

    CHOEUR DU CERN

    2010-01-01

    Les répétitions du chœur du CERN reprendront le mercredi 15 septembre à 20.00 heures à l’amphithéâtre principal – bâtiment 500. Au programme la préparation de notre concert de Noël avec la Missa Brevis, KV115, de Léopold Mozart et de la musique de Noël d’Europe. Les personnes qui aiment chanter, notamment des sopranes et des ténors, sont les bienvenues. Pour tout contact s’adresser à : Baudouin Bleus - (tél.CERN 767 82 44) -(baudouin.bleus@cern.ch) ou Martin Gatehouse ( martin.gatehouse@wanadoo.fr) ou Jean-Paul Diss (jean-pauldiss@wanadoo.fr).  

  11. Hard target LIDAR calibration for SO2

    CSIR Research Space (South Africa)

    Du Plessis, A

    2006-01-01

    Full Text Available calibration for SO2 A du Plessis, DE Roberts CSIR National Laser Centre, Pretoria Slide 2 © CSIR 2006 www.csir.co.za Project background • Las-R-MAP: Laser – Remote – Measurement of Atmospheric Pollutants • Mobile laser system....csir.co.za Hard target backscatter ∫ = − R dRRn p e R RcE RS 0 )(2 2 )()( λσ λ β S R Slide 10 © CSIR 2006 www.csir.co.za Las-R-MAP hardware: laser system Slide 11 © CSIR 2006 www.csir.co.za Las-R...

  12. A Multichannel Calorimetric Simultaneous Assay Platform Using a Microampere Constant-Current Looped Enthalpy Sensor Array

    Directory of Open Access Journals (Sweden)

    Hsien-Chin Wei

    2017-02-01

    Full Text Available Calorimetric biochemical measurements offer various advantages such as low waste, low cost, low sample consumption, short operating time, and labor-savings. Multichannel calorimeters can enhance the possibility of performing higher-throughput biochemical measurements. An enthalpy sensor (ES array is a key device in multichannel calorimeters. Most ES arrays use Wheatstone bridge amplifiers to condition the sensor signals, but such an approach is only suitable for null detection and low resistance sensors. To overcome these limitations, we have developed a multichannel calorimetric simultaneous assay (MCSA platform. An adjustable microampere constant-current (AMCC source was designed for exciting the ES array using a microampere current loop measurement circuit topology. The MCSA platform comprises a measurement unit, which contains a multichannel calorimeter and an automatic simultaneous injector, and a signal processing unit, which contains multiple ES signal conditioners and a data processor. This study focused on the construction of the MCSA platform; in particular, construction of the measurement circuit and calorimeter array in a single block. The performance of the platform, including current stability, temperature sensitivity and heat sensitivity, was evaluated. The sensor response time and calorimeter constants were given. The capability of the platform to detect relative enzyme activity was also demonstrated. The experimental results show that the proposed MCSA is a flexible and powerful biochemical measurement device with higher throughput than existing alternatives.

  13. Magnetic fluid hyperthermia probed by both calorimetric and dynamic hysteresis measurements

    Science.gov (United States)

    Guibert, Clément; Fresnais, Jérôme; Peyre, Véronique; Dupuis, Vincent

    2017-01-01

    In this paper, we report an investigation of magnetic fluid hyperthermia (MFH) using combined calorimetric and newly implemented dynamic hysteresis measurements for two sets of well characterized size-sorted maghemite nanoparticles (with diameters of about 10 nm and 20 nm) dispersed in water and in glycerol. Our primary goal was to assess the influence of viscosity on the heating efficiency of magnetic nanoparticles described in terms of specific loss power (SLP or specific absorption rate, SAR) and dynamic hysteresis. In particular, we aimed to investigate how this SLP depends on the transition from Néelian to Brownian behavior of nanoparticles expected to occur between 10 nm and 20 nm (for maghemite) and dependent on the viscosity. While we observed a good agreement between calorimetric and dynamic hysteresis measurements, we found that the SLP measured for the different systems do not depend noticeably on the viscosity of solvent. Calculations performed according to Rosensweig's linear model [1] allow us to quantitatively reproduce our results at low field intensities, provided we use a value for the magnetic anisotropy constant much smaller than the one commonly used in the literature. This raises the question of the temperature dependance of the magnetic anisotropy constant and its relevance for a quantitative description of MFH.

  14. Calorimetric determination of the δ hydride dissolution enthalpy in Zircaloy-4

    International Nuclear Information System (INIS)

    Vizcaino, Pablo; Banchik, Abraham D.

    2003-01-01

    In this work, the dissolution enthalpy, ΔH δ→α , of the δ hydride phase in the αZr matrix in Zircaloy-4 has been determined with a differential scanning calorimeter (DSC) in two different ways: by means of a vant Hoff equation, measuring the terminal solubility temperature in dissolution, TSSd, and by direct measurement of the dissolution heat, Q δ→α , as the area between the base line and the calorimetric curve. The application of the DSC technique to the hydride dissolution heat measurements, a transformation which covers an extended temperature range, is completely original and requires a special treatment of the calorimetric curve. These measurements were done on samples, which practically cover the whole solubility range of hydrogen in αZr phase (80-640 ppm). The values obtained, 36.9 kJ/mol H and 39.3 kJ/mol H respectively, are self-consistent and in good agreement with the values of the more recent revisions, but reduces considerably the scatter of the literature data. (author)

  15. Long-term measurement with calorimetric probes at unit 1 of V-1 nuclear power plant

    International Nuclear Information System (INIS)

    Erben, O.; Szasz, Z.; Jirousek, V.; Teren, S.

    1989-01-01

    Two calorimetric probes were tested at the first unit of the Bohunice V-1 nuclear power plant in long-term operation, i.e., during one whole reactor duty time. Each probe consisted of five fission calorimeters and one compensation calorimeter with a tungsten body. The actual calorimeters were provided with jacketed thermocouples 0.5 mm indiameter and 19 m in length. A detailed description is presented of the measuring chains and measurement techniques. Also described is the method of the disposal of the irradiated probes. The method is presented of the evaluation of measured data and the results are discussed of the analysis of these data. The measurements, including measurements during reactor shut-down and the results of the analysis of the measured data proved good viability and stability of the used calorimetres. The method of measuring the thermocouple signals is simple and the in-service evaluation of required data is quick. In order to increase measurement efficiency it would be appropriate to complete the measuring chain and to automate it. Reliability is a affected merely by protecting the thermocouples against mechanical damage during measurement probe handling and on the reactor. (Z.M.). 5 figs., 5 tabs., 5 refs

  16. Calorimetric Thermoelectric Gas Sensor for the Detection of Hydrogen, Methane and Mixed Gases

    Directory of Open Access Journals (Sweden)

    Nam-Hee Park

    2014-05-01

    Full Text Available A novel miniaturized calorimeter-type sensor device with a dual-catalyst structure was fabricated by integrating different catalysts on the hot (Pd/θ-Al2O3 and cold (Pt/α-Al2O3 ends of the device. The device comprises a calorimeter with a thermoelectric gas sensor (calorimetric-TGS, combining catalytic combustion and thermoelectric technologies. Its response for a model fuel gas of hydrogen and methane was investigated with various combustor catalyst compositions. The calorimetric-TGS devices detected H2, CH4, and a mixture of the two with concentrations ranging between 200 and 2000 ppm at temperatures of 100–400 °C, in terms of the calorie content of the gases. It was necessary to reduce the much higher response voltage of the TGS to H2 compared to CH4. We enhanced the H2 combustion on the cold side so that the temperature differences and response voltages to H2 were reduced. The device response to H2 combustion was reduced by 50% by controlling the Pt concentration in the Pt/α-Al2O3 catalyst on the cold side to 3 wt%.

  17. Magnetic fluid hyperthermia probed by both calorimetric and dynamic hysteresis measurements

    Energy Technology Data Exchange (ETDEWEB)

    Guibert, Clément; Fresnais, Jérôme; Peyre, Véronique; Dupuis, Vincent, E-mail: vincent.dupuis@upmc.fr

    2017-01-01

    In this paper, we report an investigation of magnetic fluid hyperthermia (MFH) using combined calorimetric and newly implemented dynamic hysteresis measurements for two sets of well characterized size-sorted maghemite nanoparticles (with diameters of about 10 nm and 20 nm) dispersed in water and in glycerol. Our primary goal was to assess the influence of viscosity on the heating efficiency of magnetic nanoparticles described in terms of specific loss power (SLP or specific absorption rate, SAR) and dynamic hysteresis. In particular, we aimed to investigate how this SLP depends on the transition from Néelian to Brownian behavior of nanoparticles expected to occur between 10 nm and 20 nm (for maghemite) and dependent on the viscosity. While we observed a good agreement between calorimetric and dynamic hysteresis measurements, we found that the SLP measured for the different systems do not depend noticeably on the viscosity of solvent. Calculations performed according to Rosensweig's linear model [1] allow us to quantitatively reproduce our results at low field intensities, provided we use a value for the magnetic anisotropy constant much smaller than the one commonly used in the literature. This raises the question of the temperature dependance of the magnetic anisotropy constant and its relevance for a quantitative description of MFH. - Highlights: • Dynamic hysteresis measurements are a promising tool to study magnetic hyperthermia. • Dynamic hysteresis cycles can be reproduced using a simple model. • The effect of viscosity on hyperthermia of maghemite is weaker than expected.

  18. Hepatiques du Surinam

    NARCIS (Netherlands)

    Jovet-Ast, S.

    1957-01-01

    Il n’existe pas, actuellement, de catalogue des Hépatiques du Surinam. Les Hépatiques de ce pays restent très peu connues. Cependant, certaines ont attiré l’attention des Bryologues et ont été citées dans quelques ouvrages anciens ou récents. Je ne ferai pas ici une révision complète de ces

  19. (l.) Medik du Maroc

    African Journals Online (AJOL)

    PR BOKO

    Résumé. Dipcadi serotinum (L.) Medik, est une plante de la famille des Hyacinthaceae, elle est largement utilisée comme réchauffant et aussi pour combattre la jaunisse. Cette plante trouve une large utilisation par la population de la région côtière du Maroc. À notre connaissance l'huile essentielle de cette espèce n'a ...

  20. La mesure du danger

    CERN Document Server

    Manceron, Vanessa; Revet, Sandrine

    2014-01-01

    La mesure du danger permet d’explorer des dangers de nature aussi diverse que la délinquance, la pollution, l’écueil maritime, la maladie ou l’attaque sorcellaire, l’extinction d’espèces animales ou végétales, voire de la Planète tout entière. Au croisement de la sociologie, de l’anthropologie et de l’histoire, les différents articles analysent les pratiques concrètes de mesure pour tenter de comprendre ce qui se produit au cours de l’opération d’évaluation du danger sans préjuger de la nature de celui-ci. L’anthropologie a contribué à la réflexion sur l’infortune en s’intéressant aux temporalités de l’après : maladies, catastrophes, pandémies, etc. et en cherchant à rendre compte de l’expérience des victimes, de leur vie ordinaire bouleversée, de la recomposition du quotidien. Elle s’intéresse aussi aux autres types de mesures, les savoirs incorporés, qui reposent sur l’odorat, la vue ou le toucher et ceux qui ressortent d’une épistémologie « non ...

  1. The Pierre Auger fluorescence detector. Cross-checking the absolute calibration using a drone

    Energy Technology Data Exchange (ETDEWEB)

    Tomankova, Lenka [Institute for Nuclear Physics (IKP), Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe (Germany); Collaboration: Pierre-Auger-Collaboration

    2016-07-01

    The Pierre Auger Observatory combines the air shower fluorescence and surface array methods to study ultra-high energy cosmic rays. As the energy scale of the experiment is derived from calorimetric measurements by the fluorescence telescopes, their accurate calibration is of primary importance to all Auger data. We discuss a novel calibration method based on a remotely flown drone equipped with a specially designed light source that mimics a snapshot of an air shower traversing the atmosphere. Several drone measurement campaigns have been performed to study the properties of the Auger fluorescence telescopes and to derive an end-to-end calibration. We give an overview of the measurements and present the basic analysis chain as well as the first results of an independent cross-check of the Auger energy scale.

  2. Absolute gain calibration system for the 349-pixel imaging element of the tactic telescope array

    International Nuclear Information System (INIS)

    Tickoo, A.K.; Dhar, V.K.; Venugopal, K.; Kaul, S.K.; Koul, R.; Bhatt, N.; Goyal, H.C.; Bhat, C.L.

    2001-01-01

    The imaging Element of the 4-element TACTIC telescope array has been in operation at Mt. Abu since 1997, for carrying detailed investigations of gamma-ray sources in the TeV energy range. In order to characterize the progenitor particle (Gamma-ray/cosmic-ray), a relative gain calibration system, based on a high intensity LED, has been in operation. However, for calorimetric purposes, an absolute gain calibration system is necessary and has been developed for an on-line calibration of 4 out of 349-pixels of its imaging camera, using 241 Am based light pulsers. The details of the experimental set-up and the results obtained so far are presented in this paper. (author)

  3. Mechanics of log calibration

    International Nuclear Information System (INIS)

    Waller, W.C.; Cram, M.E.; Hall, J.E.

    1975-01-01

    For any measurement to have meaning, it must be related to generally accepted standard units by a valid and specified system of comparison. To calibrate well-logging tools, sensing systems are designed which produce consistent and repeatable indications over the range for which the tool was intended. The basics of calibration theory, procedures, and calibration record presentations are reviewed. Calibrations for induction, electrical, radioactivity, and sonic logging tools will be discussed. The authors' intent is to provide an understanding of the sources of errors, of the way errors are minimized in the calibration process, and of the significance of changes in recorded calibration data

  4. Synthesis Polarimetry Calibration

    Science.gov (United States)

    Moellenbrock, George

    2017-10-01

    Synthesis instrumental polarization calibration fundamentals for both linear (ALMA) and circular (EVLA) feed bases are reviewed, with special attention to the calibration heuristics supported in CASA. Practical problems affecting modern instruments are also discussed.

  5. ORNL calibrations facility

    International Nuclear Information System (INIS)

    Berger, C.D.; Gupton, E.D.; Lane, B.H.; Miller, J.H.; Nichols, S.W.

    1982-08-01

    The ORNL Calibrations Facility is operated by the Instrumentation Group of the Industrial Safety and Applied Health Physics Division. Its primary purpose is to maintain radiation calibration standards for calibration of ORNL health physics instruments and personnel dosimeters. This report includes a discussion of the radioactive sources and ancillary equipment in use and a step-by-step procedure for calibration of those survey instruments and personnel dosimeters in routine use at ORNL

  6. Archives: les cahiers du cread

    African Journals Online (AJOL)

    Items 1 - 24 of 24 ... Archives: les cahiers du cread. Journal Home > Archives: les cahiers du cread. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. 1 - 24 of 24 Items. 2016 ...

  7. Le commerce du Nord

    OpenAIRE

    Pourchasse, Pierrick; Bouëdec, Gérard Le

    2015-01-01

    Au XVIIIe siècle, la France s'approvisionne abondamment dans les pays du Nord : bois, chanvre et goudron de la Baltique, tonnellerie de Poméranie, pêche de rogue de Norvège, graines de lin de Courlande, barres de fer suédois… Sa balance commerciale est pourtant positive grâce aux sels, aux vins et surtout des nouvelles marchandises coloniales. Or, la plupart des transactions passent par l’incontournable intermédiaire hollandais. Les explications sur l’absence des Français dans le Nord sont re...

  8. La voie du Centre

    OpenAIRE

    2017-01-01

    Après avoir quelque peu louvoyé dans un discours apparemment anarchique où les souvenirs semblent se bousculer sans autre fil conducteur que la référence obsédante au mal satanique, brusquement le narrateur annonce un événement primordial : Foi um fato que se deu, um dia, se abriu. O primeiro. Depois o senhor verá por quê, me devolvendo minha razão (79). Cette introduction situe la rencontre du Menino comme fondatrice d’un destin dont il reviendrait au narrataire de dégager les enchaînements....

  9. Bulletin du CRDI #126

    International Development Research Centre (IDRC) Digital Library (Canada)

    26 févr. 2018 ... Dans ce numéro, découvrez comment la recherche financée par le CRDI permet d'améliorer la santé des mères et des enfants dans les pays du Sud et comment les innovations techniques et sociales de l'initiative SEARCH permettent de surmonter les défis liés à la cybersanté. N'oubliez pas non plus de ...

  10. Total hemispherical emittance measured at high temperatures by the calorimetric method

    International Nuclear Information System (INIS)

    DiFilippo, F.; Mirtich, M.J.; Banks, B.A.; Stidham, C.; Kussmaul, M.

    1994-01-01

    A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements (± 5 percent). The probable error of the CVE measurements was typically less than 1 percent

  11. Calorimetric and spectroscopic properties of small globular proteins (bovine serum albumin, hemoglobin) after free radical generation

    International Nuclear Information System (INIS)

    Farkas, N.; Belagyi, J.; Lorinczy, D.

    2003-01-01

    Mild oxidation of -SH-containing proteins (serum albumin, hemoglobin) by Ce(IV)-ions in the presence of the spin trap phenyl-tert-butylnitrone (PBN) resulted in the appearance of strongly immobilized nitroxide free radicals which evidences the formation of thiyl radicals on the thiol site of the proteins. In hydroxyl free radical generating system a fraction of strongly immobilized nitroxide radicals was also detected in these proteins, which implies that the oxidation of a fraction of the thiol groups was also involved in the free radical reaction. According to the differential scanning calorimetry (DSC) experiments the melting processes of the proteins were calorimetrically irreversible, therefore the two-state kinetic model was used to evaluate the experiments. The results support the view that site-specific interaction of SH-containing proteins with hydroxyl and thiyl free radicals is able to modify the internal dynamics of proteins and affect the conformation of large molecules

  12. Investigation of Thermal Behavior for Natural Fibres Reinforced Epoxy using Thermogravimetric and Differential Scanning Calorimetric Analysis

    Directory of Open Access Journals (Sweden)

    Fauzi F.A.

    2016-01-01

    Full Text Available This paper presented the research works on the investigation of the thermal behavior of the natural fibres; i.e. pineapple leaf fibre, kenaf fibre and mengkuang fibres reinforced epoxy. The thermogravimetric analysis and differential scanning calorimetric analysis were used to measure the thermal behavior of the treated and untreated pineapple, kenaf and mengkuang fibres reinforced epoxy. The samples for both analysis were subjected to maximum temperature 600°C at the heating rate of 10°C/min. The results showed that the treated fibres show higher maximum peak temperature as compared to the untreated fibres. Additionally, the glass transition temperature showed a lower value for all treated fibre. It can be concluded that investigation of thermal properties of these natural fibres could improve the utilization of natural fibre composites in various applications i.e. sports applications.

  13. Standardization of 3H, 14C and 63Ni radiation sources by calorimetric method

    International Nuclear Information System (INIS)

    Khol'nova, E.A.; Kul'kova, L.P.

    1979-01-01

    The calorimetric method of determination of activity of radionuclides 3 H, 14 C and 63 Ni with low mean energies of β-particles has, as compare to other methods which had been used for determination of activity of these nuclides, a number of advantages, because a nuclide to be measured can be introduced into the calorimeter in any physical and chemical state. It is not necessary to distroy integrity ane leek-proofness of a source wnich can be of arbitrary type. There is no correction for absorption and self-absorption of β-particles and measuring instruments are relatively simple. As a limitation of this method is it's low sensitivity which can be owercomed by means of application of modern high sensitivity calorimeters. Such calorimeters have been developed in the Mendeleev All-Union research Institute. The calorimetric installation consists of 3 independent β-calorimeters of differential-double type, working in the regime of heat equilibrium and beeng intended for different by sise and shape sources. Then, there are thermostatting device of special desighn and electric measuring device. Number of thermocouples in each calorimeter is from 75 to 120 and sensitivity of calorimeters is from 2.45x10 -7 to 4.5x10 -7 Bt/mm depending on the type of calorimeter. Calorimeters are intended for measuring activities from 10 9 to 10 12 Bk. Error of measurement of activities equals 0.8-1.5% (with confidence level of 0.99%). The main portion of error consists of error in the medium energy β-spectra. The calorimeter error itself is much more lower. Soueces, which have been measured in the calorimeter than can be used for preparation of solutions and sources of lower activity [ru

  14. Choeur du CERN : Concert

    CERN Multimedia

    CERN Choir

    2017-01-01

    Une œuvre à découvrir! La grande Missa pro defunctis de François-Joseph Gossec (1734-1829) est le chef-d’œuvre tôt venu (à vingt-cinq ans) d’un compositeur qui vivra encore 70 ans après sa création. Elle a connu la gloire, puis s’est fait un peu oublier. Pas du tout le monde cependant : des musicologues ont montré ce que le Requiem de Mozart lui devait ; et il suffit de l’avoir entendue pour comprendre pourquoi Berlioz (qui avait vingt-six ans à la mort de Gossec) en a été impressionné : les nombreux cuivres et bois répartis dans des endroits plus ou moins cachés de la salle de concert pour exprimer les frayeurs du Jugement dernier annoncent son Requiem – et celui de Verdi. Mais « plus encore que par...

  15. Les risques du travail

    CERN Document Server

    Thébaud-Mony, Annie

    2015-01-01

    Depuis les années 1990, les conditions de travail se sont peu à peu imposées dans le débat social. Néanmoins, la situation reste critique. Les risques traditionnels n'ont pas disparu : les manutentions lourdes, l'exposition professionnelle aux cancérogènes, au bruit ou aux vibrations demeurent répandues... De plus, certaines " améliorations " n'ont fait que déplacer et dissimuler les problèmes, telle l'externalisation des risques grâce à la sous-traitance. Dans le même temps, les transformations du travail et des modalités de gestion de la main-d'œuvre ont fragilisé les collectifs et accru l'isolement des salariés, conduisant à une montée visible de la souffrance psychique. Face à ces évolutions, il est plus que jamais nécessaire que tous les acteurs concernés, en particulier les salariés eux-mêmes et leurs représentants, s'approprient les connaissances indispensables pour améliorer la protection de la santé sur les lieux du travail. Tel est le but de ce livre, qui renouvelle int�...

  16. Jouer du piano

    Directory of Open Access Journals (Sweden)

    Fériel Kaddour

    2011-04-01

    Full Text Available La réflexion s’appuie dans un premier temps sur une opposition entre deux attitudes de pianistes  à l’égard du travail à l’instrument : Gould, qui revendique une séparation d’avec le clavier pour ne privilégier que la lecture; Arrau, dont la technique au contraire vise à « faire corps » avec son piano. L’étude de ces deux démarches d’interprètes conduit à une conclusion croisée : l’abstraction gouldienne n’est rien d’autre qu’un déplacement du jeu vers d’autres instruments (ceux qui servent à la prise de son et au montage de ses enregistrements ; le « faire-corps » hérité de la culture pianistique romantique est plus dialectique que fusionnel, et en cela implique une capacité de mise à distance. A partir de cette double conclusion, on tâche enfin de repenser la place du jeu à l’instrument dans la mise en œuvre d’une interprétation, en interrogeant le dialogue qui s’instaure entre la partition telle qu’elle s’écrit et le geste tel qu’il se joue.Our study leans on an opposition between two pianists' attitudes about their work with the instrument. Gould claims a necessary separation from the keyboard in order to prioritize reading. Arrau, on the contrary, relies on a technique which consists in “being one” with his piano. The analysis of these two interprets’ behaviours leads to a crossed conclusion: the gouldian abstraction is nothing else than a displacement of the playing towards another kind of instruments, the ones he uses in sound recording and cut up; Arrau’s “being one” is more dialectic than at first sight, and it therefore implies a real distancing from the piano. This constatation leads to rethink the place of the piano playing in the setting of an interpretation, and to highlight the real dialogue which develops itself between the score as it has been written and the gesture as it is played.

  17. Test of the little Higgs model in Atlas at LHC: simulation of the digitization of the electromagnetic calorimeter; Test du modele du petit Higgs dans ATLAS au LHC: simulation de la numerisation du calorimetre electromagnetique

    Energy Technology Data Exchange (ETDEWEB)

    Lechowski, M

    2005-04-15

    LHC is a proton-proton collider with an energy of 14 TeV in the center of mass, which will start operating in 2007 at CERN. Two of its experiments, ATLAS, and CMS, will search and study in particular the Higgs boson, Supersymmetry and other new physics. This thesis was about two aspects of the ATLAS experiment. On one hand the simulation of the liquid Argon electromagnetic calorimeter, with the emulation of the electronic chain in charge of the digitization of the signal and also the evaluation of the electronic noise and the pile-up noise (coming from minimum bias events of inelastic collisions at LHC). These two points have been validated by the analysis of the data taken during beam tests in 2002 and 2004. On the other hand, a physics study concerning the Little Higgs model. This recent model solves the hierarchy problem of the Standard Model, in introducing new heavy particles to cancel quadratic divergences arising in the calculation of the Higgs boson mass. These new particles, with a mass about the TeV/c{sup 2}, are a heavy quark top, heavy gauge bosons Z{sub H}, W{sub H} and A{sub H}, and a heavy Higgs boson triplet. The physics study dealt with the characteristic decays of the model, Z{sub H} in Z + H and W{sub H} in W + H, with a Higgs mass either at 120 GeV/c{sup 2} decaying in two photons or at 200 GeV/c{sup 2} decaying in ZZ or WW. Results show that in both cases, for 300 fb{sup -1} (3 years at high luminosity), an observation of the signal at 5 {sigma} for Z{sub H} et W{sub H} masses less than 2 TeV/c{sup 2} is possible, covering a large part of the parameter space. (author)

  18. La grammaticalisation du monde.

    Directory of Open Access Journals (Sweden)

    Etienne Pingaud

    2010-01-01

    Full Text Available Ouvrage atypique par le fond comme par la forme, Le devoir et la grâce rend compte du minutieux travail d’élaboration théorique auquel s’attelle Cyril Lemieux depuis plusieurs années. Et le résultat final se veut pour le moins ambitieux : l’auteur propose un système total supposé dépasser d’un même élan le relativisme, le mentalisme, l’universalisme ethnocentrique, l’historicisme, le naturalisme et l’herméneutisme, tout en réconciliant les sciences sociales avec le ...

  19. Le sacre du printemps

    Directory of Open Access Journals (Sweden)

    Denise Pumain

    2002-03-01

    Full Text Available Cybergeo aura six ans en avril : dans la réalité du virtuel, dans l'univers récent et fluctuant de la publication en ligne, cela fait de nous, tout à la fois, des pionniers et des vétérans. De façon plus surprenante, il se trouve que nous sommes aussi uniques : parmi toutes les revues électroniques de sciences sociales, aucune ne combine comme Cybergeo ancienneté, publication exclusivement électronique, liberté d'accès au texte intégral, édition et gestion par des chercheurs, et comité de lec...

  20. Le Brahmane du Komintern

    Directory of Open Access Journals (Sweden)

    Elizabeth Burgos

    2008-01-01

    Full Text Available Le Brahmane du Komintern, largometraje documental del realizador francés Vladimir León, constituye un ejercicio ejemplar de investigación histórica y  de lograda factura de realización. Y, pese a no haber contado con la ayuda de ninguno organismo público, se trata de un ambicioso proyecto que cubre una amplia extensión geográfica que abarca: Estados Unidos, México, Moscú, Berlín, y la India. Gira en torno a una figura que tuvo en su tiempo su hora de gloria. Un bengalí, hijo de braman, la c...

  1. (Sorghum bicolor (L.) Moench) du Nord du Burkina Faso

    African Journals Online (AJOL)

    SARAH

    29 déc. 2014 ... sorghos à grains sucrés ont un cycle court et arrivent donc à maturité avant les autres sorghos et le mil d'où leur exploitation comme aliment de soudure par les paysans. L'organisation de la diversité morphologique des accessions de sorghos à grains sucrés du Nord du. Burkina autour principalement des ...

  2. OPERATION DU FOISONNEMENT

    Directory of Open Access Journals (Sweden)

    Gholamreza Djelveh

    2010-04-01

    Full Text Available Mousses alimentaires sont un sous-ensemble des aliments connus sous le nom de produits fouettés ou des produits aérés. Ils sont des produits formulés avec des qualités telles que la légèreté et la souplesse et sont principalement consommés à l'apéritif ou au dessert. Les produits en mousse obtenue par dispersion d'un gaz dans une matrice alimentaire (la phase continue ont connu un développement croissant au cours des années 80 et 90. Le processus d'aération liés à leurs activités de production est appelée l'expansion ou à fouetter. Le document présente les principaux-paramètres du procédé du point permanent de la formulation, la mise en œuvre processus dans les installations pilotes et à l'échelle industrielle, la caractérisation des produits finis, la base énergétique de l'échelle de processus en place, et le lien entre la formulation, émulsion préparation de l'expansion. Cette vue d'ensemble de l'opération d'expansion continue, nous a permis de mettre en évidence le fait qu'il ya des opérations de l'unité encore mal décrite par le génie des procédés et pour lesquels les méthodes et outils pour l'extrapolation et la prédiction sont encore à leurs balbutiements.

  3. Calibration of Flick standards

    International Nuclear Information System (INIS)

    Thalmann, Ruedi; Spiller, Jürg; Küng, Alain; Jusko, Otto

    2012-01-01

    Flick standards or magnification standards are widely used for an efficient and functional calibration of the sensitivity of form measuring instruments. The results of a recent measurement comparison have shown to be partially unsatisfactory and revealed problems related to the calibration of these standards. In this paper the influence factors for the calibration of Flick standards using roundness measurement instruments are discussed in detail, in particular the bandwidth of the measurement chain, residual form errors of the device under test, profile distortions due to the diameter of the probing element and questions related to the definition of the measurand. The different contributions are estimated using simulations and are experimentally verified. Also alternative methods to calibrate Flick standards are investigated. Finally the practical limitations of Flick standard calibration are shown and the usability of Flick standards both to calibrate the sensitivity of roundness instruments and to check the filter function of such instruments is analysed. (paper)

  4. Alimentation du nouveau-ne et du nourrisson dans la region ...

    African Journals Online (AJOL)

    Alimentation du nouveau-ne et du nourrisson dans la region centrale du togo : pratiques familiales et communautaires avant la mise en oeuvre de la strategie « prise en charge integree des maladies de l'enfant »

  5. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  6. The calorimetric spectrum of the electron-capture decay of $^{163}$Ho. A preliminary analysis of the preliminary data

    CERN Document Server

    De Rújula, A.

    2015-01-01

    It is in principle possible to measure directly the electron neutrino mass (or masses and mixing angles) in weak electron-capture decays. The optimal nuclide in this respect is $^{163}$Ho. The favoured experimental technique, currently pursued in various experiments (ECHo, HOLMES and NuMECS) is "calorimetric". The calorimetric energy spectrum is a sum over the unstable vacant orbitals, or "holes", left by the electrons weakly captured by the nucleus. We discuss the current progress in this field and analize the preliminary data. Our conclusion is that, as pointed out by Robertson, the contribution of two-hole states is not negligible. But --in strong contradistinction with the tacit conclusion of previous comparisons of theory and observations-- we find a quite satisfactory agreement. A crucial point is that, in the creation of secondary holes, electron shakeoff and not only electron shakeup must be taken into account.

  7. Theoretical and experimental study of a calorimetric technique for measuring energy deposition in materials caused by complex pile irradiation

    International Nuclear Information System (INIS)

    Mas, P.; Sciers, P.; Droulers, Y.

    1962-01-01

    Calorimetric methods may be used to measure gamma fluxes greater than 10 6 r/h near the cores of swimming pool reactors. The theory, design, and properties of isothermal calorimeters are discussed, and experimental results obtained with two types are presented. Measurement of energy deposition in materials and the long term integration of energy depositions are other uses of these devices. Results of measurements on heat deposition in steel and water are given. Fluxes were also measured. (authors) [fr

  8. PCCE-A Predictive Code for Calorimetric Estimates in actively cooled components affected by pulsed power loads

    International Nuclear Information System (INIS)

    Agostinetti, P.; Palma, M. Dalla; Fantini, F.; Fellin, F.; Pasqualotto, R.

    2011-01-01

    The analytical interpretative models for calorimetric measurements currently available in the literature can consider close systems in steady-state and transient conditions, or open systems but only in steady-state conditions. The PCCE code (Predictive Code for Calorimetric Estimations), here presented, introduces some novelties. In fact, it can simulate with an analytical approach both the heated component and the cooling circuit, evaluating the heat fluxes due to conductive and convective processes both in steady-state and transient conditions. The main goal of this code is to model heating and cooling processes in actively cooled components of fusion experiments affected by high pulsed power loads, that are not easily analyzed with purely numerical approaches (like Finite Element Method or Computational Fluid Dynamics). A dedicated mathematical formulation, based on concentrated parameters, has been developed and is here described in detail. After a comparison and benchmark with the ANSYS commercial code, the PCCE code is applied to predict the calorimetric parameters in simple scenarios of the SPIDER experiment.

  9. Le plurilinguisme du perroquet

    Directory of Open Access Journals (Sweden)

    Manuel Mühlbacher

    2012-05-01

    Full Text Available La figure du perroquet occupe une position ambiguë face à la question de la traduction. Il est capable d’imiter des paroles en toutes les langues, mais il n’est capable d’en comprendre aucune — il ne peut que répéter des sons, c’est-à-dire des signifiants. Le traducteur semble faire le contraire quand il passe d’une langue à une autre en tâchant de transmettre une signification semblable par d’autres signes. L’article vise à discuter le rôle du traducteur et sa relation, éventuellement équivoque, au perroquet, en analysant la traduction allemande de Trois Contes par André Stoll et Cora van Kleffens. Un décalage au niveau sémantique peut éclairer l’interprétation du texte, par exemple en explicitant des allusions sous-jacentes, tandis que le transfert de la syntaxe française en allemand pose souvent des problèmes considérables. Comment le traducteur peut-il reproduire des structures syntaxiques qui n’existent pas en allemand, mais qui ne cessent de revenir dans le texte français ? Que faire si le texte se met à jouer au perroquet et finit par se singer lui-même ? André Stoll et Cora van Kleffens ont su trouver des stratégies pour affronter ces difficultés.The figure of the parrot holds an ambiguous position towards the question of translation. It is able to imitate all languages, but it will never understand any of them – its only skill is to mimic sounds, i.e. mere signifiers. On the contrary, the translator seems to be the antithesis of the parrot when he moves from one language to another. He endeavours to convey a similar meaning, but by different signs. The article aims at discussing the role of the translator and his or her eventually equivocal relation to the parrot by means of analysing the German translation of Trois Contes by André Stoll and Cora van Kleffens. Whereas a semantic divergence can result in a different tendency on the level of interpretation, as in the case of an underlying

  10. Calibration of moisture monitors

    International Nuclear Information System (INIS)

    Gutierrez, R.L.

    1979-02-01

    A method for calibrating an aluminum oxide hygrometer against an optical chilled mirror dew-point hygrometer has been established. A theoretical cross-point line of dew points from both hygrometers and a maximum moisture content of 10 ppM/sub v/ are used to define an area for calibrating the sensor probes of the aluminum oxide hygrometer

  11. Site Calibration report

    DEFF Research Database (Denmark)

    Yordanova, Ginka; Vesth, Allan

    The report describes site calibration measurements carried out on a site in Denmark. The measurements are carried out in accordance to Ref. [1]. The site calibration is carried out before a power performance measurement on a given turbine to clarify the influence from the terrain on the ratio...

  12. Topics in Statistical Calibration

    Science.gov (United States)

    2014-03-27

    Natural cubic spline speed di st 110 B.2 The calibrate function The most basic calibration problem, the one often encountered in more advanced ...0040-1706, 1537-2723. A. M. Mood, F. A. Graybill, and D. C. Boes. Introduction to the Theory of Statistics. McGraw-Hill, Auckland , U.A, 1974. ISBN

  13. Etat Du Magnesium Dans Quelques Sols Sales Du Sud Et Du ...

    African Journals Online (AJOL)

    étude a été réalisée sur 86 échantillons de sols provenant du Centre et du Sud de l´Irak. L\\'expérimentation a consisté, d´une part, à calculer les différents sels dominants dans les sols salés par la méthode de combinaison hypothétique et, ...

  14. Caractérisation des sables et morphologie du fond du lac du ...

    African Journals Online (AJOL)

    Une analyse sédimentologique et minéralogique réalisée sur un cycle hydrologique entre octobre 2004 et août 2005 a permis d\\'évaluer les charges solides en suspension et de caractériser les sédiments du lac du barrage de Taabo. La concentration moyenne en matières en suspension (12 mg.L-1) et la turbidité ...

  15. Caractérisation des sables et morphologie du fond du lac du ...

    African Journals Online (AJOL)

    Administrateur

    Une analyse sédimentologique et minéralogique réalisée sur un cycle hydrologique entre octobre 2004 et août 2005 a permis d'évaluer les charges solides en suspension et de caractériser les sédiments du lac du barrage de Taabo. La concentration moyenne en matières en suspension (12 mg.L-1) et la turbidité ...

  16. Sandia WIPP calibration traceability

    Energy Technology Data Exchange (ETDEWEB)

    Schuhen, M.D. [Sandia National Labs., Albuquerque, NM (United States); Dean, T.A. [RE/SPEC, Inc., Albuquerque, NM (United States)

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities.

  17. The GERDA calibration system

    Energy Technology Data Exchange (ETDEWEB)

    Baudis, Laura; Froborg, Francis; Tarka, Michael; Bruch, Tobias; Ferella, Alfredo [Physik-Institut, Universitaet Zuerich (Switzerland); Collaboration: GERDA-Collaboration

    2012-07-01

    A system with three identical custom made units is used for the energy calibration of the GERDA Ge diodes. To perform a calibration the {sup 228}Th sources are lowered from the parking positions at the top of the cryostat. Their positions are measured by two independent modules. One, the incremental encoder, counts the holes in the perforated steel band holding the sources, the other measures the drive shaft's angular position even if not powered. The system can be controlled remotely by a Labview program. The calibration data is analyzed by an iterative calibration algorithm determining the calibration functions for different energy reconstruction algorithms and the resolution of several peaks in the {sup 228}Th spectrum is determined. A Monte Carlo simulation using the GERDA simulation software MAGE has been performed to determine the background induced by the sources in the parking positions.

  18. Sandia WIPP calibration traceability

    International Nuclear Information System (INIS)

    Schuhen, M.D.; Dean, T.A.

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities

  19. Development of a superconducting transition edge thermometer for calorimetric detection of heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Meier, J; Boehmer, W; Egelhof, P; Henning, W; Kienlin, A v [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany) Mainz Univ. (Germany). Inst. fuer Physik; Shepard, K W [Argonne National Lab., IL (United States)

    1991-10-01

    A low temperature bolometer for the calorimetric detection of heavy ions was constructed and tested. An aluminium thin-film microstrip, patterned in a meander-line structure by photolithographic techniques, serves as superconducting transition edge thermometer on a sapphire absorber. A transition width {delta}T of the thermometer of the order of some mK, and a resistance of up to R{sub c} = 60 k{Omega} at the working point (T{sub c} {approx equal} 1.5 K) is achieved. In tests with {alpha}-particles signals of typically 1 V pulseheight after the preamplifier and decaytimes around hundred {mu}s were observed. For 5.5 MeV {alpha}-particles the measured energy resolution is {Delta}E = 50 keV, corresponding to a temperature resolution of about 1 {mu}K. First measurements were performed with {sup 20}Ne ions (E = 116 MeV). The dependence of the pulseheight and the FWHM on the working point were investigated and qualitatively explained. The best energy resolution was {Delta}E = 2.6 MeV; most probably the present limitations are determined by the temperature stabilization. (orig.).

  20. Systematic study of packaging designs on the performance of CMOS thermoresistive micro calorimetric flow sensors

    International Nuclear Information System (INIS)

    Xu, Wei; Gao, Bo; Xu, Kun; Lee, Yi-Kuen; Pan, Liang; Chiu, Yi

    2017-01-01

    We systematically study the effect of two packaging configurations for the CMOS thermoresistive micro calorimetric flow (TMCF) sensors: S-type with the sensor chip protrusion-mounted on the flow channel wall and E-type with the sensor chip flush-mounted on the flow channel wall. Although the experimental results indicated that the sensitivity of the S-type was increased by more than 30%; the corresponding flow range as compared to the E-type was dramatically reduced by 60% from 0–11 m s −1 to 0–4.5 m s −1 . Comprehensive 2D CFD simulation and in-house developed 3D numerical simulations based on the gas-kinetic scheme were applied to study the flow separation of these two packaging designs with the major parameters. Indeed, the S-type design with the large protrusion would change the local convective heat transfer of the TMCF sensor and dramatically decrease the sensors’ performance. In addition, parametric CFD simulations of the packaging designs provide inspiration to propose a novel general flow regime map (FRM), i.e. normalized protrusion d * versus reduced chip Reynolds number Re * , where the critical boundary curve for the flow separation of TMCF sensors was determined at different channel aspect ratios. The proposed FRM can be a useful guideline for the packaging design and manufacturing of different micro thermal flow sensors. (paper)

  1. Calorimetric measurement of heat load in full non-inductive LHCD plasmas on TRIAM-1M

    International Nuclear Information System (INIS)

    Hanada, K.; Shinoda, N.; Sugata, T.; Sasaki, K.; Zushi, H.; Nakamura, K.; Sato, K.N.; Sakamoto, M.; Idei, H.; Hasegawa, M.; Kawasaki, S.; Nakashima, H.; Higashijima, A.

    2007-01-01

    Calorimetric measurements using the temperature increment of cooling-water were carried out to estimate the heat load distribution on the plasma facing components (PFCs) in the limiter discharges on TRIAM-1M. Line averaged electron density, n e , and LH power, P LH , dependences of the heat load on PFCs were measured. The heat load on the limiters was proportional to n e 1.5 in the range of n e =0.2-1.0x10 19 m -3 and P LH 1 in the range of P LH =0.005-0.09MW. For P LH >0.1MW, the plasma transition to an enhanced current drive (ECD) mode appeared and the n e dependences on the heat load on the limiter moderated. This indicates that the heat flux to scrape-off layer (SOL) region was reduced due to the improvement of the plasma confinement. The up-down asymmetry of the heat load on the vacuum vessel was enhanced in the ECD mode, which may be caused by the increasing of the direct loss of energetic electrons

  2. Phase transitions in the urea/n-nonadecane system by calorimetric techniques

    International Nuclear Information System (INIS)

    Lopez-Echarri, A; Ruiz-Larrea, I; Fraile-RodrIguez, A; Diaz-Hernandez, J; Breczewski, T; Bocanegra, E H

    2007-01-01

    A calorimetric study of urea/n-nonadecane, CO(NH 2 ) 2 /C 19 H 40 , and the deuterated derivatives, CO(ND 2 ) 2 /C 19 D 40 and CO(NH 2 ) 2 /C 19 D 40 , around the structural phase transition temperature is presented. For this purpose differential scanning (DSC), temperature-modulated (AC) and adiabatic calorimetry have been used and the obtained results are compared. Leaving apart the noticeable peak associated with the main phase transition at 158.5, 149.4 and 154 K respectively, small anomalies of the specific heat are found at lower temperatures and their corresponding entropic and enthalpic changes are reported. Heating and cooling experiments show the influence of the temperature rate and the thermal history on the detailed profile of the specific heat traces. The presence of thermal hysteresis and latent heat as a way to characterize the order of the phase transitions is discussed. Finally, a tentative approach to the urea and the alkyl chain contributions to the specific heat and their influence on the phase transition mechanisms is presented

  3. Electron energy and charge albedos - calorimetric measurement vs Monte Carlo theory

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Ruggles, L.E.; Miller, G.H.; Halbleib, J.A.

    1981-11-01

    A new calorimetric method has been employed to obtain saturated electron energy albedos for Be, C, Al, Ti, Mo, Ta, U, and UO 2 over the range of incident energies from 0.1 to 1.0 MeV. The technique was so designed to permit the simultaneous measurement of saturated charge albedos. In the cases of C, Al, Ta, and U the measurements were extended down to about 0.025 MeV. The angle of incidence was varied from 0 0 (normal) to 75 0 in steps of 15 0 , with selected measurements at 82.5 0 in Be and C. In each case, state-of-the-art predictions were obtained from a Monte Carlo model. The generally good agreement between theory and experiment over this extensive parameter space represents a strong validation of both the theoretical model and the new experimental method. Nevertheless, certain discrepancies at low incident energies, especially in high-atomic-number materials, and at all energies in the case of the U energy albedos are not completely understood

  4. Calorimetric evidence for two distinct molecular packing arrangements in stable glasses of indomethacin.

    Science.gov (United States)

    Kearns, Kenneth L; Swallen, Stephen F; Ediger, M D; Sun, Ye; Yu, Lian

    2009-02-12

    Indomethacin glasses of varying stabilities were prepared by physical vapor deposition onto substrates at 265 K. Enthalpy relaxation and the mobility onset temperature were assessed with differential scanning calorimetry (DSC). Quasi-isothermal temperature-modulated DSC was used to measure the reversing heat capacity during annealing above the glass transition temperature Tg. At deposition rates near 8 A/s, scanning DSC shows two enthalpy relaxation peaks and quasi-isothermal DSC shows a two-step change in the reversing heat capacity. We attribute these features to two distinct local packing structures in the vapor-deposited glass, and this interpretation is supported by the strong correlation between the two calorimetric signatures of the glass to liquid transformation. At lower deposition rates, a larger fraction of the sample is prepared in the more stable local packing. The transformation of the vapor-deposited glasses into the supercooled liquid above Tg is exceedingly slow, as much as 4500 times slower than the structural relaxation time of the liquid.

  5. The CALorimetric Electron Telescope (CALET for high-energy astroparticle physics on the International Space Station

    Directory of Open Access Journals (Sweden)

    Adriani O.

    2015-01-01

    Full Text Available The CALorimetric Electron Telescope (CALET is a space experiment, currently under development by Japan in collaboration with Italy and the United States, which will measure the flux of cosmic-ray electrons (and positrons up to 20 TeV energy, of gamma rays up to 10 TeV, of nuclei with Z from 1 to 40 up to 1 PeV energy, and will detect gamma-ray bursts in the 7 keV to 20 MeV energy range during a 5 year mission. These measurements are essential to investigate possible nearby astrophysical sources of high energy electrons, study the details of galactic particle propagation and search for dark matter signatures. The main detector of CALET, the Calorimeter, consists of a module to identify the particle charge, followed by a thin imaging calorimeter (3 radiation lengths with tungsten plates interleaving scintillating fibre planes, and a thick energy measuring calorimeter (27 radiation lengths composed of lead tungstate logs. The Calorimeter has the depth, imaging capabilities and energy resolution necessary for excellent separation between hadrons, electrons and gamma rays. The instrument is currently being prepared for launch (expected in 2015 to the International Space Station ISS, for installation on the Japanese Experiment Module - Exposure Facility (JEM-EF.

  6. Studies of atomic collisions in solids by means of calorimetric techniques

    International Nuclear Information System (INIS)

    Andersen, H.H.

    1974-10-01

    The results of the application of the calorimetric technique to measure the way in which the energy of particles passed through a thin foil and stopped within a solid block is disturbed between the foil and the block are presented. This measurement gives the relative energy loss of the projectile in the foil and hence, since the foil thickness is measured independently, the stopping power. Radiation-damage measurements are discussed. In these measurements, the same cryostat as that employed in the stopping-power measurements was used. The foil was left out and the block remained as a very efficient dosimetry device. Furthermore, a number of experimental complications must be taken into account when damage is measured. Finally, results are presented of the measurement of energy distribution between two systems, this time performed at room temperature. The measurements are not nearly as accurate as those performed at low temperatures, but the physical property studied, the energy reflected from a solid surface bombarded with low-energy heavy ions (sputtering efficiency) could hardly be studied in any other way. The thesis is a summary of thirteen publications on energetic-particle calorimetry, all these papers being reproduced as appendices to the main text. (B.R.H.)

  7. Specific binding of a dihydropyrimidinone derivative with DNA: Spectroscopic, calorimetric and modeling investigations

    International Nuclear Information System (INIS)

    Wang Gongke; Yan Changling; Wang Dongchao; Li Dan; Lu Yan

    2012-01-01

    One of the dihydropyrimidinone derivative 5-(ethoxycarbonyl)-6-methyl-4-(4-methoxyphenyl) -3,4-dihydropyrimidin-2(1H)-one (EMMD) was synthesized, and its binding properties with calf-thymus DNA (ctDNA) were investigated using spectroscopic, viscometric, isothermal titration calorimetric (ITC) and molecular modeling techniques. Fluorescence spectra suggested that the fluorescence enhancement of the binding interaction of EMMD to ctDNA was a static process with ground state complex formation. The binding constant determined with spectroscopic titration and ITC was found to be in the same order of 10 4 M −1 . According to the results of the viscosity analysis, fluorescence competitive binding experiment, fluorescence quenching studies, absorption spectral and ITC investigations, it can be concluded that EMMD is intercalative binding to ctDNA. Furthermore, the results of molecular modeling confirmed those obtained from spectroscopic, viscosimetric and ITC investigations. Additionally, ITC studies also indicated that the binding interaction is predominantly enthalpy driven. - Highlights: ► Medically important dihydropyrimidinones derivative EMMD is synthesized. ► EMMD is intercalative binding into ctDNA helix. ► Hydrogen bonding may play an essential role in the binding of EMCD with ctDNA. ► This binding interaction is predominantly enthalpy driven.

  8. Calorimetric features of IgM gammopathies. Implication for patient’s diagnosis and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Krumova, Sashka; Todinova, Svetla; Danailova, Avgustina [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., bl. 21, 1113 Sofia (Bulgaria); Petkova, Violeta; Dimitrova, Keranka; Gartcheva, Lidia [National Specialized Hospital for Active Treating of Haematological Diseases, Sofia 1756 (Bulgaria); Taneva, Stefka G., E-mail: stefka.germanova@ehu.es [Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Acad. G. Bonchev Str., bl. 21, 1113 Sofia (Bulgaria); Unidad de Biofísica (CSIC-UPV/EHU) and Departamento de Bioquímica y Biología Molecular, Universidad del País Vasco, 48080 Bilbao (Spain)

    2015-09-10

    Highlights: • DSC reveals distinct calorimetric features for IgM gammopaties. • Calorimetry sets of IgM multiple myeloma and Waldenström’s macroglobulinemia patients. • DSC features correlate with the level of involved IgM heavy/light chains. • DSC and “Heavylite” are complementary methods for patients diagnostics/monitoring. - Abstract: The serum proteome of patients featuring immunoglobulin M (IgM) gammopathy and diagnosed as having IgM multiple myeloma or Waldenström’s macroglobulinemia was characterized by differential scanning calorimetry and HevyLite™ (HLC) assay. The thermodynamic properties of the thermograms and their deviation from the typical healthy thermogram were found to correlate with the monoclonal protein concentration and the level of the involved (monoclonal) IgM heavy/light chains. Patients monitoring during treatment showed that the variations in the shape of the DSC profiles corresponded to fluctuations of the IgM heavy/light chain levels verifying the two parameters as non-invasive markers for disease progression.

  9. Reactivity of Monolayer Protected Silver Clusters Towards Excess Ligand: A Calorimetric Study

    KAUST Repository

    Baksi, Ananya

    2017-10-31

    Reactivity of monolayer protected atomically precise clusters of noble metals is of significant research interest. Till date very few experimental data are available on the reaction thermodynamics of such clusters. Here we report a calorimetric study of the reaction of glutathione (GSH) protected silver clusters in presence of excess ligand, GSH using isothermal titration calorimetry (ITC). We have studied Ag11(SG)7 and Ag32(SG)19 clusters and compared their reactivity with GSH protected silver nanoparticles (AgNPs) and silver ions. Clusters show intermediate reactivity towards excess ligand com-pared to nanoparticles and silver ions. Several control experiments were performed to understand the degradation mech-anism of these silver clusters and nanoparticles. Effect of dissolved oxygen in the degradation process was studied in de-tail and found that it did not have a significant role, although alternate pathways of degradation with the involvement of oxygen cannot be ruled out. Direct confirmation of the fact that functionalized metal clusters fall in-between NPs and atomic systems in their stability is obtained experimentally for the first time. Several other thermophysical parameters of these clusters were also determined including, density, speed of sound, isentropic compressibility and coefficient of thermal expansion.

  10. Interaction of chloroquine and its analogues with heme: An isothermal titration calorimetric study.

    Science.gov (United States)

    Bachhawat, K; Thomas, C J; Surolia, N; Surolia, A

    2000-10-05

    Quinoline-containing drugs such as chloroquine and quinine have had a long and successful history in antimalarial chemotherapy. Identification of ferriprotoporphyrin IX ([Fe(III)PPIX], haematin) as the drug receptors for these antimalarials called for investigations of the binding affinity, mode of interaction, and the conditions affecting the interaction. The parameters obtained are significant in recent times with the emergence of chloroquine resistant strains of the malaria parasites. This has underlined the need to unravel the molecular mechanism of their action so as to meet the requirement of an alternative to the existing antimalarial drugs. The isothermal titration calorimetric studies on the interaction of chloroquine with haematin lead us to propose an altered mode of binding. The initial recognition is ionic in nature mediated by the propionyl group of haematin with the quaternary nitrogen on CQ. This ionic interaction induces a conformational change, such as to favour binding of subsequent CQ molecules. On the contrary, conditions emulating the cytosolic environment (pH 7.4 and 150 mM salt) reveal the hydrophobic force to be the sole contributor driving the interaction. Interaction of a carefully selected panel of quinoline antimalarial drugs with monomeric ferriprotoporphyrin IX has also been investigated at pH 5.6 mimicking the acidic environment prevalent in the food vacuoles of parasite, the center of drug activity, which are consistent with their antimalarial activity. Copyright 2000 Academic Press.

  11. First calorimetric determination of heat of extraction of 248Cm in a bi-phasic system

    International Nuclear Information System (INIS)

    Martin, Leigh R.; Zalupski, Peter R.

    2011-01-01

    This report presents a summary of the work performed to meet FCR and D level 2 milestone M21SW050201, 'Complete the first calorimetric determination of heat of extraction of 248Cm in a bi-phasic system'. This work was carried out under the auspices of the Thermodynamics and Kinetics FCR and D work package. To complement previous work undertaken under this work package we have extended out heat of extraction studies by di-2-ethyl-hexyl-phosphoric acid to curium. This report also details the heat of extraction of samarium in the same system. This work was performed to not only test the methodology but also to check for consistency with the heats of extraction obtained with those in the prior literature. The heat of extraction for samarium that was obtained in this study was -9.6 kJ mol-1, which is in reasonable agreement with the previously obtained value of -10.9 kJ mol-1. The curium heat of extraction was performed under two sets of conditions and the obtained heats of extraction were in reasonable agreement with each other at -16.0 ± 1.1 and -16.8 ± 1.5 kJ mol-1.

  12. Experiencias de calorimetría diferencial de barrido en aleaciones Al-Si

    Directory of Open Access Journals (Sweden)

    Carolina López-Eckerdt

    2016-01-01

    Full Text Available La observación de agujas características de una transformación displaciva en aleaciones U-Al-Si en el entorno del compuesto U3Si5 evidencia la necesidad de analizar las distintas transformaciones que ocurren durante el enfriamiento utilizando una técnica dinámica de identificación de transformaciones (calorimetría diferencial de barrido. Para evaluar la versatilidad de esta técnica, se estudiaron aleaciones Al-Si con concentraciones de Si entre 0,6% y 7,1% en peso. Se determinaron las temperaturas liquidus y eutéctica de cada aleación y se estimó la entalpía de formación de los precipitados de Si y de la reacción eutéctica. Los resultados reproducen las temperaturas de ambas reacciones según el diagrama de equilibrio del sistema binario Al-Si. Para el cálculo de las entalpías de transformación resulta indispensable obtener el porcentaje de fase transformada por otras técnicas de caracterización una vez finalizado el ensayo.

  13. Thermal explosion analysis of methyl ethyl ketone peroxide by non-isothermal and isothermal calorimetric applications

    International Nuclear Information System (INIS)

    Chi, Jen-Hao; Wu, Sheng-Hung; Shu, Chi-Min

    2009-01-01

    In the past, process incidents attributed to organic peroxides (OPs) that involved near misses, over-pressures, runaway reactions, and thermal explosions occurred because of poor training, human error, incorrect kinetic assumptions, insufficient change management, and inadequate chemical knowledge in the manufacturing process. Calorimetric applications were employed broadly to test organic peroxides on a small-scale because of their thermal hazards, such as exothermic behavior and self-accelerating decomposition in the laboratory. In essence, methyl ethyl ketone peroxide (MEKPO) is highly reactive and exothermically unstable. In recent years, it has undergone many thermal explosions and runaway reaction incidents in the manufacturing process. Differential scanning calorimetry (DSC), vent sizing package 2 (VSP2), and thermal activity monitor (TAM) were employed to analyze thermokinetic parameters and safety index. The intent of the analyses was to facilitate the use of various auto-alarm equipments to detect over-pressure, over-temperature, and hazardous materials leaks for a wide spectrum of operations. Results indicated that MEKPO decomposition is detected at low temperatures (30-40 deg. C), and the rate of decomposition was shown to exponentially increase with temperature and pressure. Determining time to maximum rate (TMR), self-accelerating decomposition temperature (SADT), maximum temperature (T max ), exothermic onset temperature (T 0 ), and heat of decomposition (ΔH d ) was essential for identifying early-stage runaway reactions effectively for industries.

  14. a Calorimetric Study of the Precipitation Hardening Mechanisms in AN Al-Cu-Mg-Si Alloy

    Science.gov (United States)

    Hayoune, Abdelali

    2013-08-01

    The precipitation phenomena and the related hardening in an Al-Cu-Mg-Si alloy were studied by calorimetry, X-ray diffraction analysis and microhardness measurements. The main calorimetric peaks were identified to be due to β‧‧, θ‧ and Q‧ phases precipitation. The hardening during aging at room temperature and 160°C, was respectively, explained by atomic clusters and GP zones formation and by GP zones and β‧‧/θ‧ phases coprecipitation. Although the mechanical properties variation during aging at 200°C is simple, the corresponding microstructural evolution is complex: on the basis of the DSC results, the increasing of microhardness values, is mainly due to the coprecipitation of GP zones and β‧‧/θ‧ phases, however, the maximum hardening is explained by the coexistence of β‧‧/θ‧ and θ‧‧ phases. Another important conclusion is that during aging at 160°C and 200°C, the θ‧ phase is essentially developed from GP zones.

  15. Calorimetric studies and lessons on fires and explosions of a chemical plant producing CHP and DCPO

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Jing-Ming; Su, Mao-Sheng; Huang, Chiao-Ying [Department of Occupational Safety and Health, Chia Nan University of Pharmacy and Science, Tainan, Taiwan, ROC (China); Duh, Yih-Shing, E-mail: yihshingduh@yahoo.com.tw [Department of Safety, Health and Environmental Engineering, National United University, No. 1 Lien-Da, Miaoli, Taiwan, ROC (China)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer We analyzed fire and explosion incidents in a plant producing CHP and DCPO. Black-Right-Pointing-Pointer Data from calorimeters reveal causes and phenomena associated with the incidents. Black-Right-Pointing-Pointer The credible worst scenario was thermal explosion. Black-Right-Pointing-Pointer Incidents may be avoided by implementing DIERS methodology. - Abstract: Cumene hydroperoxide (CHP) has been used in producing phenol, dicumyl peroxide (DCPO) and as an initiator for synthesizing acrylonitrile-butadiene-styrene (ABS) resin by copolymerization in Taiwan. Four incidents of fire and explosion induced by thermal runaway reactions were occurred in a same plant producing CHP, DCPO and bis-(tert-butylperoxy isopropyl) benzene peroxide (BIBP). The fourth fire and explosion occurred in the CHP reactor that resulted in a catastrophic damage in reaction region and even spread throughout storage area. Descriptions on the occurrences of these incidents were assessed by the features of processes, reaction schemes and unexpected side reactions. Calorimetric data on thermokinetics and pressure were used for explaining the practical consequences or which the worst cases encountered in this kind of plant. Acceptable risk associated with emergency relief system design is vital for a plant producing organic peroxide. These basic data for designing an inherently safer plant can be conducted from adiabatic calorimetry. An encouraging deduction has been drawn here, these incidents may be avoided by the implementation of API RP 520, API RP 521, DIERS technology, OSHA 1910.119 and AIChE's CCPS recommended PSM elements.

  16. Calorimetric studies and lessons on fires and explosions of a chemical plant producing CHP and DCPO

    International Nuclear Information System (INIS)

    Hsu, Jing-Ming; Su, Mao-Sheng; Huang, Chiao-Ying; Duh, Yih-Shing

    2012-01-01

    Highlights: ► We analyzed fire and explosion incidents in a plant producing CHP and DCPO. ► Data from calorimeters reveal causes and phenomena associated with the incidents. ► The credible worst scenario was thermal explosion. ► Incidents may be avoided by implementing DIERS methodology. - Abstract: Cumene hydroperoxide (CHP) has been used in producing phenol, dicumyl peroxide (DCPO) and as an initiator for synthesizing acrylonitrile–butadiene–styrene (ABS) resin by copolymerization in Taiwan. Four incidents of fire and explosion induced by thermal runaway reactions were occurred in a same plant producing CHP, DCPO and bis-(tert-butylperoxy isopropyl) benzene peroxide (BIBP). The fourth fire and explosion occurred in the CHP reactor that resulted in a catastrophic damage in reaction region and even spread throughout storage area. Descriptions on the occurrences of these incidents were assessed by the features of processes, reaction schemes and unexpected side reactions. Calorimetric data on thermokinetics and pressure were used for explaining the practical consequences or which the worst cases encountered in this kind of plant. Acceptable risk associated with emergency relief system design is vital for a plant producing organic peroxide. These basic data for designing an inherently safer plant can be conducted from adiabatic calorimetry. An encouraging deduction has been drawn here, these incidents may be avoided by the implementation of API RP 520, API RP 521, DIERS technology, OSHA 1910.119 and AIChE's CCPS recommended PSM elements.

  17. Calorimetric investigation on mechanically activated storage energy mechanism of sphalerite and pyrite

    International Nuclear Information System (INIS)

    Xiao Zhongliang; Chen Qiyuan; Yin Zhoulan; Hu Huiping; Wu Daoxin

    2005-01-01

    The structural changes of mechanically activated sphalerite and pyrite under different grinding conditions were determined by X-ray powder diffraction (XRD), laser particle size analyzer and elemental analysis. The storage energy of mechanically activated sphalerite and pyrite was measured by a calorimetric method. A thermochemical cycle was designed so that mechanically activated and non-activated minerals reached the same final state when dissolved in the same oxidizing solvent. The results show that the storage energy of mechanically activated sphalerite and pyrite rises with increased in grinding time, and reaches a maximum after a certain grinding period. The storage energy of mechanically activated pyrite decreases when heated under inert atmosphere. The storage energy of mechanically activated sphalerite and pyrite remains constant when treated below 573 K under inert atmosphere. The percentage of the storage energy caused by surface area increase during mechanical activation decreases with increasing grinding time. These results support our opinion that the mechanically activated storage energy of sphalerite is closely related to lattice distortions, and the mechanically activated storage energy of pyrite is mainly caused by the formation of reactive sites on the surface

  18. Status and performance of the CALorimetric Electron Telescope (CALET) on the International Space Station

    Energy Technology Data Exchange (ETDEWEB)

    Adriani, O. [University of Florence, IFAC (CNR) and INFN (Italy); Akaike, Y. [ICRR, University of Tokyo (Japan); Asaoka, Y. [Waseda University (Japan); Asano, K. [Tokyo Institute of Technology (Japan); Bagliesi, M.G.; Bigongiari, G. [University of Siena and INFN (Italy); Binns, W.R. [Washington University-St. Louis (United States); Bongi, M. [University of Florence, IFAC (CNR) and INFN (Italy); Buckley, J.H. [Washington University-St. Louis (United States); Cassese, A.; Castellini, G. [University of Florence, IFAC (CNR) and INFN (Italy); Cherry, M.L. [Louisiana State University (United States); Collazuol, G. [University of Padova and INFN (Italy); Ebisawa, K. [JAXA/ISAS (Japan); Di Felice, V. [University of Rome Tor Vergata and INFN (Italy); Fuke, H. [JAXA/ISAS (Japan); Guzik, T.G. [Louisiana State University (United States); Hams, T. [CRESST/NASA/GSFC and University of Maryland (United States); Hasebe, N. [Waseda University (Japan); Hareyama, M. [St. Marianna University School of Medicine (Japan); and others

    2014-11-15

    The CALorimetric Electron Telescope (CALET) space experiment, currently under development by Japan in collaboration with Italy and the United States, will measure the flux of cosmic-ray electrons (including positrons) to 20 TeV, gamma rays to 10 TeV and nuclei with Z=1 to 40 up to 1,000 TeV during a two-year mission on the International Space Station (ISS), extendable to five years. These measurements are essential to search for dark matter signatures, investigate the mechanism of cosmic-ray acceleration and propagation in the Galaxy and discover possible astrophysical sources of high-energy electrons nearby the Earth. The instrument consists of two layers of segmented plastic scintillators for the cosmic-ray charge identification (CHD), a 3 radiation length thick tungsten-scintillating fiber imaging calorimeter (IMC) and a 27 radiation length thick lead-tungstate calorimeter (TASC). CALET has sufficient depth, imaging capabilities and excellent energy resolution to allow for a clear separation between hadrons and electrons and between charged particles and gamma rays. The instrument will be launched to the ISS within 2014 Japanese Fiscal Year (by the end of March 2015) and installed on the Japanese Experiment Module-Exposed Facility (JEM-EF). In this paper, we will review the status and main science goals of the mission and describe the instrument configuration and performance.

  19. Le bal du loup

    CERN Multimedia

    Happy Children's Home

    2013-01-01

    The Bord'eau amateur theatre group will graciously perform a play of their creation Le bal du loup Saturday 19 October 2013 at 20:00 Sunday 20 October at 17:00 in the Théâtre des Grottes Rue Louis Favre 43, 1201 Genève Children from age 12 upwards. Summary: The new-elected mayoress of a small village would like to clean up the town by prohibiting alcohol and getting rid of its prostitutes. Then along comes « Massimo Lupo » the pimp... The performances will be given to support the Happy Children's Home charity, which runs a foster-home in Pokhara for Nepali children:  http://www.happychildrenshome.org/ Admission : minimum charge of 10 CHF per person requested, to cover the cost of technical assistance and theatre rental. Any profit will be used solely for the foster-home. At the end of each performance members of the HCH charity will be happy to answer any questions you may have. The theatre has 86 seats, thank you for reserv...

  20. Compact radiometric microwave calibrator

    International Nuclear Information System (INIS)

    Fixsen, D. J.; Wollack, E. J.; Kogut, A.; Limon, M.; Mirel, P.; Singal, J.; Fixsen, S. M.

    2006-01-01

    The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency

  1. Lidar to lidar calibration

    DEFF Research Database (Denmark)

    Fernandez Garcia, Sergio; Villanueva, Héctor

    This report presents the result of the lidar to lidar calibration performed for ground-based lidar. Calibration is here understood as the establishment of a relation between the reference lidar wind speed measurements with measurement uncertainties provided by measurement standard and corresponding...... lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from the reference lidar measurements are given for information only....

  2. Effets de la microdose sur la production du niébé, du mil et du ...

    African Journals Online (AJOL)

    Effets de la microdose sur la production du niébé, du mil et du sorgho en fonction la toposéquence. Fatimata Saba, Sibiri Jean Baptiste Taonda, Idriss Serme, Alimata A. Bandaogo, Augustin P. Sourwema, Adama Kabre ...

  3. Dynamique des populations du foreur des tiges du cacaoyer ...

    African Journals Online (AJOL)

    SARAH

    30 nov. 2014 ... déprédateur dans la région du Haut-Sassandra, la deuxième plus grande région de production de cacao en. Côte d'ivoire. Méthodologie et résultats : L'étude a été réalisée de 2009 à 2013 dans les plantations villageoises de la région du Haut-Sassandra en Côte d'Ivoire. Les variations des taux d'attaques ...

  4. Dynamique des populations du foreur des tiges du cacaoyer ...

    African Journals Online (AJOL)

    Objectif : Le foreur de tiges du cacaoyer, Eulophonotus myrmeleon Felder cause aujourd'hui d'énormes dégâts dans les cacaoyères ivoiriennes. La présente étude vise à déterminer les périodes de fortes attaques de ce déprédateur dans la région du Haut-Sassandra, la deuxième plus grande région de production de ...

  5. Gestion durable du paysage

    Directory of Open Access Journals (Sweden)

    Jean-David Gerber

    2009-03-01

    Full Text Available Le paysage est de plus en plus perçu comme une ressource. À ce titre, il est nécessaire de trouver des instruments juridiques, politiques ou économiques susceptibles de gérer cette « ressource-paysage » sur le long terme. Le gouvernement suisse a introduit récemment l’instrument des parcs naturels régionaux, organisés selon le modèle français, dans sa législation de protection de la nature et du paysage. Une mise en regard des nouveaux parcs avec des structures de gestion beaucoup plus anciennes, les bourgeoisies et les corporations, permet de mettre en évidence les forces et les faiblesses de chacun de ces instruments dans leur contribution à résoudre les rivalités d’usage entre acteurs utilisant ou influençant la ressource paysage. Cette comparaison permet de formuler des recommandations pratiques concernant la gestion de cette ressource.The landscape is increasingly perceived as a resource. For this reason, it is necessary to find legal, political and economic instruments that will succeed in managing this “resource landscape” in the long term. The Swiss government recently introduced the instrument of regional nature parks into the legislation governing nature and landscape preservation; the proposed parks are organized on the basis of the French model. The examination of the new parks from the perspective of much older management structures, i.e. the civic municipalities (bourgeoisies and corporations, makes it possible to demonstrate the strengths and weaknesses of each of these instruments in their contribution to the resolution of use rivalries between actors who use or influence the resource landscape. This comparison also enables the formulation of practical recommendations regarding the management of this resource.

  6. Le Developmental Entrepreneurship Program du Massachusetts ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Faire en sorte que les étudiants venant des pays en développement pour étudier au MIT retournent ensuite dans leurs pays respectifs afin d'y concrétiser leurs idées est un souci majeur du MIT, des bailleurs de fonds et du milieu du développement. Ce projet palliera à ce souci en soutenant la formation des fellows du ...

  7. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  8. SRHA calibration curve

    Data.gov (United States)

    U.S. Environmental Protection Agency — an UV calibration curve for SRHA quantitation. This dataset is associated with the following publication: Chang, X., and D. Bouchard. Surfactant-Wrapped Multiwalled...

  9. BES online calibration system

    International Nuclear Information System (INIS)

    Zhang Bingyun; Li Xiaonan; Zhu Kejun; Zhang Jiawen; Gong Mingyu

    2003-01-01

    We constructed BES (Beijing Spectrometer) online calibration system to ensure the coherence of readout electronic channels due to huge data volume in high energy physics experiment. This paper describes the structure of hardware and software, and its characteristic and function

  10. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ahlers, C.F.; Liu, H.H.

    2001-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the AMR Development Plan for U0035 Calibrated Properties Model REV00 (CRWMS M and O 1999c). These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions

  11. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ahlers, C.; Liu, H.

    2000-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the ''AMR Development Plan for U0035 Calibrated Properties Model REV00. These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions

  12. SPOTS Calibration Example

    Directory of Open Access Journals (Sweden)

    Patterson E.

    2010-06-01

    Full Text Available The results are presented using the procedure outlined by the Standardisation Project for Optical Techniques of Strain measurement to calibrate a digital image correlation system. The process involves comparing the experimental data obtained with the optical measurement system to the theoretical values for a specially designed specimen. The standard states the criteria which must be met in order to achieve successful calibration, in addition to quantifying the measurement uncertainty in the system. The system was evaluated at three different displacement load levels, generating strain ranges from 289 µstrain to 2110 µstrain. At the 289 µstrain range, the calibration uncertainty was found to be 14.1 µstrain, and at the 2110 µstrain range it was found to be 28.9 µstrain. This calibration procedure was performed without painting a speckle pattern on the surface of the metal. Instead, the specimen surface was prepared using different grades of grit paper to produce the desired texture.

  13. Les dispositifs du Net art

    OpenAIRE

    Fourmentraux, Jean-Paul

    2010-01-01

    La pratique du Net art radicalise la question du potentiel communicationnel d’un média —Internet— qui constitue tout à la fois le support technique, l’outil créatif et le dispositif social de l’œuvre. Les technologies de l’information et de la communication (TIC) placent en effet l’œuvre d’art au cœur d’une négociation socialement distribuée entre l’artiste et le public. L’article est focalisé sur cette construction collective du Net art et sur ses mises en scènes. Il montre le travail artist...

  14. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  15. Calibration of thermoluminiscent materials

    International Nuclear Information System (INIS)

    Bos, A.J.J.

    1989-07-01

    In this report the relation between exposure and absorbed radiation dose in various materials is represented, on the base of recent data. With the help of this a calibration procedure for thermoluminescent materials, adapted to the IRI radiation standard is still the exposure in rontgen. In switching to the air kerma standard the calibration procedure will have to be adapted. (author). 6 refs.; 4 tabs

  16. L'administration du travail et la production du droit du travail (1906-1960). : Note de synthèse du rapport de recherche

    OpenAIRE

    Le Crom , Jean-Pierre

    2007-01-01

    Synthèse d'un rapport de recherche dont l'objectif est d'appréhender le rôle de l'administration centrale du travail dans la production du droit du travail. Deux dimensions sont explorées : le profil des rédacteurs et l'organisation des structures.

  17. Calibrating nacelle lidars

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, M.

    2013-01-15

    Nacelle mounted, forward looking wind lidars are beginning to be used to provide reference wind speed measurements for the power performance testing of wind turbines. In such applications, a formal calibration procedure with a corresponding uncertainty assessment will be necessary. This report presents four concepts for performing such a nacelle lidar calibration. Of the four methods, two are found to be immediately relevant and are pursued in some detail. The first of these is a line of sight calibration method in which both lines of sight (for a two beam lidar) are individually calibrated by accurately aligning the beam to pass close to a reference wind speed sensor. A testing procedure is presented, reporting requirements outlined and the uncertainty of the method analysed. It is seen that the main limitation of the line of sight calibration method is the time required to obtain a representative distribution of radial wind speeds. An alternative method is to place the nacelle lidar on the ground and incline the beams upwards to bisect a mast equipped with reference instrumentation at a known height and range. This method will be easier and faster to implement and execute but the beam inclination introduces extra uncertainties. A procedure for conducting such a calibration is presented and initial indications of the uncertainties given. A discussion of the merits and weaknesses of the two methods is given together with some proposals for the next important steps to be taken in this work. (Author)

  18. Thermodynamic properties of a smectite and an illite: comparison between solubility experiments and calorimetric results

    International Nuclear Information System (INIS)

    Gailhanou, H.; Gaboreau, S.; Gaucher, E.C.; Blanc, P.; Rogez, J.; Olives, J.; Amouric, M.; Van Miltenburg, J.C.; Michau, N.; Giffaut, E.

    2010-01-01

    Document available in extended abstract form only. In the context of nuclear waste repositories in argillaceous formations, it is necessary to assess the geochemical behaviour of natural and engineered clay barriers, namely by the stability of clay minerals over long periods of time. However, thermodynamic data of clay minerals, which are required for geochemical modelling, are still poorly known. The present study aims to improve our comprehension of clay mineral stability. The thermodynamic properties of smectite MX-80 and illite IMt-2 (Silver Hill, Montana) have already been determined using calorimetric methods between 0 K and 520 K, under both dried and hydrated states in the case of smectite. In parallel, solubility experiments were carried out in order to determine the solubility products of the clay minerals. Such experiments require some particular precautions as published by May et al. (1986) and Aja and Rosenberg (1992). According to these authors, it is namely important to reach the equilibrium from both under and over saturation and to characterize from a mineralogical point of view the end products. Taking advantage of previous calorimetric measurements, we propose to compare the solubility products obtained here from dissolution experiments with respect to calorimetry results, in order to assess the equilibrium achievement for the solubility experiments. The study is integrated in the Thermochimie project, which aims to provide a consistent thermodynamic database (Thermochimie) for modelling purposes. This work dealing with a smectite and an illite is being completed by the study of a set of typical clays, selected to be well-representative of the clay group. Enthalpies of formation of the minerals were determined by isothermal dissolution calorimetry at 25 deg. C, using a HF-HNO 3 solution. They were obtained by measuring the enthalpies of dissolution of (i) the sample (clay mineral + impurities) and (ii) the oxide or hydroxide constituent mixture

  19. Thermodynamics and binding mechanism of polyphenon-60 with human lysozyme elucidated by calorimetric and spectroscopic techniques

    International Nuclear Information System (INIS)

    Yasmeen, Shama; Riyazuddeen

    2017-01-01

    Highlights: • Thermodynamics of the binding of Lys with polypenone-60 were studied. • The binding was found to be exothermic. • Polyphenon-60 quenches the fluorescence of Lys through static quenching. • Polyphenon-60 binds to Lys through hydrogen binding. • Conformational changes of Lys were studied using circular dichorism. - Abstract: Protein-drug interaction offer information of the structural features that determine the therapeutic effectiveness of drug and have become an attractive research field in life science, chemistry, and clinical medicine. Interaction of pharmacologically important antioxidant drug polyphenon-60 with human lysozyme (Lys) at physiological pH 7.4 has been studied by using calorimetric and various spectroscopic techniques. UV–visible spectroscopy results indicate the complex formation between Lys and polyphenon-60. The binding constant, quenching mechanism and the number of binding sites were determined by the fluorescence quenching spectra of Lys in presence of polyphenon-60. Fluorescence data indicate that the polyphenon-60 interact with Lys through static quenching mechanism with binding affinity of 2.9 × 10 4 M −1 . The average binding distance between drug and Lys was found to be 2.89 nm on the basis of the theory of Förster's energy transfer. Isothermal titration calorimetry (ITC) data reveals the thermodynamic investigations which suggest that the interaction of Lys and polyphenon-60 through exothermic process and enthalpy driven and also explore that the polyphenon-60 binds in both sites of Lys with high and low affinity. Hydrogen bonding (high affinity) and hydrophobic interactions (low affinity) are the major forces in stabilizing the drug protein complex. Far-UV CD and FTIR results deciphere the conformational alterations in the secondary structure of Lys.

  20. Calorimetric measurement of afterheat in target materials for the accelerator production of tritium

    International Nuclear Information System (INIS)

    Perry, R.B.

    1994-01-01

    The estimate of afterheat in a spallation target of lead (Pb) or tungsten (W), by calorimetry, is the purpose of this experiment in support of the Accelerator Production of Tritium (APT). Such measurements are needed to confirm code calculations, these being the only practical way of gaining this type of information in a form suitable to aid the design of the APT machine. Knowledge of the magnitude and duration of afterheat resulting from decay of activation products produced by proton bombardment of the target is necessary to quantify APT safety assumptions, to design target cooling and safety systems, and to reduce technical risk. Direct calorimetric measurement of the afterheat for the appropriate incident proton energies is more reliable than the available alternative, which is indirect, based on data from gamma-ray spectroscopy measurements. The basic concept, a direct measurement of decay afterheat which bypasses the laborious classical way of determining this quantity, has been demonstrated to work. The gamma-ray energy given off by the decay products produced in the activation of lead or tungsten with high-energy protons apparently does represent a significant fraction of the total decay energy. A calorimeter designed for measurement of isotopes decaying by alpha emission must be modified to reduce energy lost with escaping gamma rays. Replacement of the aluminum liner with a tungsten liner in the SSC measurement chamber resulted in a 270% increase in measured heat, proving that the energy loss in the earlier (1992) measurements was significant. Gamma-ray measurements are needed to confirm the gamma-ray absorption calculations for the calorimeter to determine the correction for loss of heat due to transmission of high-energy gamma rays through the calorimeter walls. The experiments at BLIP have shown that calorimetry can be a useful tool in measuring the afterheat in APT target materials

  1. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    Science.gov (United States)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity

  2. Experimental study of the heat of combustion of electrical cables: Pitcairn/calorimetre test bench

    International Nuclear Information System (INIS)

    Gautier, B.; Bosseboeuf, G.

    1995-11-01

    The R and D has been developing for about ten years, through the MAGIC software, a modeling program on the propagation of fire in power plants. The potential fuels in a power plant are mainly limited to the oils existing in engines and control systems, and electric cables. Those cables present a complex combustion due to their fire-resistant design. In order to study that combustion, two test benches, the PITCAIRN oven and the CALORIMETRE EDF/CNRS have been linked. This report presents briefly the experimental installation, then it comments on the first experimental data obtained with two types of samples, a PVC and an EPR-Hypalon cable. The tested cables are selected from those commonly used in French Nuclear Power Plants. They present complex components (fire-retarding chemical agents, mechanical reinforcement). The data show that the behavior of those cables cannot be reduced to a mass loss rate associated to a constant Heat of Combustion. The Heat of Combustion of the PVC cable tested varies little at the beginning of the pyrolysis from 5 kJ.g -1 to 10 kJ.g -1 , then increases quickly up to 30 kJ.g -1 . In the same way, the EPR-Hypalon cable shows a continuous and slow increase of the Heat of Combustion from 1 kJ.g -1 to 20 kJ.g -1 during the pyrolysis, then rises quickly up to 40 kJ.g -1 at the end. Those data corroborate the thesis of the dilution of flammable species by fire-retarding agents, which lower the Heat of combustion but seems to disappear at the end of the pyrolysis. (authors). 7 refs., 6 figs

  3. Réflexion sur l’origine du processus de segmentation du marche du travail

    Directory of Open Access Journals (Sweden)

    Attia Nicole

    2006-01-01

    Full Text Available (francuski Ce travail propose une réflexion sur l'origine du processus de segmentation du marché du travail par rapport à l'entreprise. Se situe-t-elle au sein même de l'entreprise ou en amont, c'est à dire entre les entreprises? Cela revient à se demander si on peut avoir une approche microéconomique ou macroéconomique de la segmentation et, à s'interroger sur le rôle réel tenu par les firmes dans le processus. Déterminant pour la théorie, ce rôle est à repenser selon la réponse apportée à notre question.

  4. Etude de la mesure du paramètre alpha dans le cadre de la violation de la symétrie CP à l'aide du canal $B_{d}^{0} \\to \\pi^{+} \\pi^{-}\\pi^{0}$ dans l'expérience LHCb

    CERN Document Server

    Robert, Arnaud

    2005-01-01

    L'analyse temporelle du correlogramme de Dalitz du canal a trois corps Bd en pi+ pi- pi0 conduit a l'extraction de l'un des parametres definissant la violation de la symetrie CP dans le Modele Standard Electrofaible, l'angle alpha, exempte d'ambiguites discretes entre 0 et pi. Elle permet, entre autres, d'acceder independamment aux valeurs des principaux parametres QCD regissant la desintegration. La contrepartie experimentale repose cependant sur une statistique de signal suffisamment pure et importante et une maitrise precise de la phenomenologie associee. Combines a un rapport d'embranchement de l'ordre de 2.10^{-5}, ces deux arguments justifient a eux seuls le caractere non trivial d'une telle analyse dans l'environnement hadronique de l'experience dediee LHCb. A partir de la reponse simulee du detecteur, et en particulier des performances du calorimetre electromagnetique, cette these montre l'interet essentiel de la reconstruction specifique des pions neutres tres energiques et la necessite d'introduire ...

  5. Development, calibration and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

    International Nuclear Information System (INIS)

    Carcreff, H.; Cloute-Cazalaa, V.; Salmon, L.

    2011-01-01

    Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

  6. Development, calibration, and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

    International Nuclear Information System (INIS)

    Carcreff, Hubert; Cloute-Cazalaa, Veronique; Salmon, Laurent

    2012-01-01

    Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Division at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

  7. Calorimetry of energy-efficient glow discharge apparatus design and calibration

    International Nuclear Information System (INIS)

    Benson, Thomas B.; Passell, Thomas O.

    2006-01-01

    This work aims to develop a 'family' or low-powered calorimetrically accurate glow discharge units, similar to that reported by Dardik et al. at lCCF-10, and to use these to test a wide range or cathode materials, electrode coatings, gas types, gas pressures, and power input levels. We will describe the design and calibration of these units. The strategy is to use a large number of very similar units so that the calorimetric response does not vary significantly for a given power level. The design is metal or sealed glass cylindrical tubes, charged with 0.4 - 50 Torr mixtures of deuterium, hydrogen, argon, or helium gases. Units operate from 0.2 to >2 W power input. The units have low mass ( 1.2 with more than 95% certainty. It provides a valuable new platform for large-scale exploration of excess heat effects in the gas phase, using low-power inputs in the 0-3 W range, This method proves to be inexpensive, quick, accurate, and easy to perform once the basics are mastered. The authors are interested in testing electrode materials from other sources, especially those that have already been successful in a liquid (electrolytic) environment

  8. Investigation of interaction of phosphorotungstenvanadium heteropolyacids with sodium hydroxide by the methods of calorimetric and potentiometric titration

    International Nuclear Information System (INIS)

    Ganelina, E.Sh.; Borgoyakov, S.A.

    1985-01-01

    Interaction of phosphorotungstenvanadium heteropolyacids (HPA) with alkali (NaOH) is studied by the methods of calorimetric and potentiometric titration. Three stages are singled out: 1) neutralization of ''strong'' hydrogen atoms with a constant thermal effect of 52.0+-1.6 kJ/mol; 2) neutralization of ''weak'' protons, which acidity constant is of order 10 -2 ; 3) interaction of NaOH with hydrogen atoms combined with the internal sphere of HPA, and completed by HPA destruction. The data obtained are compared with the results, calculating the composition of polymer particles inside HPA, and they are discussed from the view point of their micellar structure

  9. Characterisation of lead-calcium alloys ageing in anisothermal conditions by calorimetric, resistance and hardness in-situ measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, F.; Lambertin, M. [Arts et Metiers ParisTech, LaBoMaP, Cluny (France); Delfaut-Durut, L. [CEA, Centre de Valduc, (SEMP, LECM), Is-sur-Tille (France); Maitre, A. [SPCTS, UFR Sciences et techniques, Limoges (France); Vilasi, M. [LCSM, Univ. Nancy I, Vandoeuvre les Nancy (France)

    2010-02-15

    Transformations undergone by lead-calcium alloys are numerous and have different kinetics from a few minutes to a few years. Anisothermal calorimetric measurements were performed to be able to identify these transformations quickly. It was then possible to identify five transformations. Complementary measurements have enabled us to define transformations with an in-situ electrical resistance measurement to follow the evolution of the calcium in solid solution and with an in-situ hardness measurement to characterise the mechanical properties. The aim of these results is to simulate the ageing and overageing of the alloy in isothermal conditions. (orig.)

  10. Calorimetric investigation into interaction in Zr0.8Ti0.2CrFe-H2 system

    International Nuclear Information System (INIS)

    Sirotina, R.A.; Verbetskij, V.N.

    1993-01-01

    For studying Zr 0.8 Ti 0.2 CrFe-H 2 system is applied the calorimetric method with usage of the Tian-Calve type calorimeter. It is shown that up to 488 K in the system there are three characteristic regions: α (hydrogen solution in an intermetallic compounds (IMC)), β (hydrogen solution in a hydride) and α + β (region of coexistence of two phases). Temperature 448 K is near to critical one, when exceeding of which exists only hydrogen solution in a metal matrix. Pressure dependence of hydrogen content in IMC is described satisfactorily by a linear equation

  11. Un Nouveau Monde du Savoir

    International Development Research Centre (IDRC) Digital Library (Canada)

    Si les effets de la mondialisation sur l'économie, la politique ou encore les ..... Il souligne l'importance cruciale d'un plan stratégique d'internationalisation, ...... Lors du recrutement de nouveaux professeurs ( lorsque cette situation est ...

  12. rive gauche du fleuve Rimac

    International Development Research Centre (IDRC) Digital Library (Canada)

    tégée du fleuve et les terrains vagues d'une zone industrielle. .... Ces deux diagnostics sont d'importants outils qui contri- bueront à une meilleure planification ... conditions et instruments nécessaires pour améliorer la situation financière des ...

  13. Voorwoord Forward | du Plessis | Lexikos

    African Journals Online (AJOL)

    J.CM.D. du Plessis. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions ...

  14. Charte du Conseil des Gouverneurs

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    7. favoriser des communications ouvertes et franches entre le personnel, la direction ..... de dresser le procès-verbal des réunions du Conseil et de ses comités et de veiller à ce ... et des résultats qu'il obtient, et non de sa gestion quotidienne.

  15. Bases biologiques du comportement social

    CERN Document Server

    Laborit, H

    1994-01-01

    Pour bien comprendre le comportement humain dans un environnement social,il est necessaire de comprendre comment fonctionne le systÂ?me nerveux central. L'une des principales fonctions du cerveau est de crÂ?er des relations entre leshumains.. .................

  16. POLCAL - POLARIMETRIC RADAR CALIBRATION

    Science.gov (United States)

    Vanzyl, J.

    1994-01-01

    Calibration of polarimetric radar systems is a field of research in which great progress has been made over the last few years. POLCAL (Polarimetric Radar Calibration) is a software tool intended to assist in the calibration of Synthetic Aperture Radar (SAR) systems. In particular, POLCAL calibrates Stokes matrix format data produced as the standard product by the NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). POLCAL was designed to be used in conjunction with data collected by the NASA/JPL AIRSAR system. AIRSAR is a multifrequency (6 cm, 24 cm, and 68 cm wavelength), fully polarimetric SAR system which produces 12 x 12 km imagery at 10 m resolution. AIRSTAR was designed as a testbed for NASA's Spaceborne Imaging Radar program. While the images produced after 1991 are thought to be calibrated (phase calibrated, cross-talk removed, channel imbalance removed, and absolutely calibrated), POLCAL can and should still be used to check the accuracy of the calibration and to correct it if necessary. Version 4.0 of POLCAL is an upgrade of POLCAL version 2.0 released to AIRSAR investigators in June, 1990. New options in version 4.0 include automatic absolute calibration of 89/90 data, distributed target analysis, calibration of nearby scenes with calibration parameters from a scene with corner reflectors, altitude or roll angle corrections, and calibration of errors introduced by known topography. Many sources of error can lead to false conclusions about the nature of scatterers on the surface. Errors in the phase relationship between polarization channels result in incorrect synthesis of polarization states. Cross-talk, caused by imperfections in the radar antenna itself, can also lead to error. POLCAL reduces cross-talk and corrects phase calibration without the use of ground calibration equipment. Removing the antenna patterns during SAR processing also forms a very important part of the calibration of SAR data. Errors in the

  17. Vibration transducer calibration techniques

    Science.gov (United States)

    Brinkley, D. J.

    1980-09-01

    Techniques for the calibration of vibration transducers used in the Aeronautical Quality Assurance Directorate of the British Ministry of Defence are presented. Following a review of the types of measurements necessary in the calibration of vibration transducers, the performance requirements of vibration transducers, which can be used to measure acceleration, velocity or vibration amplitude, are discussed, with particular attention given to the piezoelectric accelerometer. Techniques for the accurate measurement of sinusoidal vibration amplitude in reference-grade transducers are then considered, including the use of a position sensitive photocell and the use of a Michelson laser interferometer. Means of comparing the output of working-grade accelerometers with that of previously calibrated reference-grade devices are then outlined, with attention given to a method employing a capacitance bridge technique and a method to be used at temperatures between -50 and 200 C. Automatic calibration procedures developed to speed up the calibration process are outlined, and future possible extensions of system software are indicated.

  18. Calibration Under Uncertainty.

    Energy Technology Data Exchange (ETDEWEB)

    Swiler, Laura Painton; Trucano, Timothy Guy

    2005-03-01

    This report is a white paper summarizing the literature and different approaches to the problem of calibrating computer model parameters in the face of model uncertainty. Model calibration is often formulated as finding the parameters that minimize the squared difference between the model-computed data (the predicted data) and the actual experimental data. This approach does not allow for explicit treatment of uncertainty or error in the model itself: the model is considered the %22true%22 deterministic representation of reality. While this approach does have utility, it is far from an accurate mathematical treatment of the true model calibration problem in which both the computed data and experimental data have error bars. This year, we examined methods to perform calibration accounting for the error in both the computer model and the data, as well as improving our understanding of its meaning for model predictability. We call this approach Calibration under Uncertainty (CUU). This talk presents our current thinking on CUU. We outline some current approaches in the literature, and discuss the Bayesian approach to CUU in detail.

  19. Ibis ground calibration

    International Nuclear Information System (INIS)

    Bird, A.J.; Barlow, E.J.; Tikkanen, T.; Bazzano, A.; Del Santo, M.; Ubertini, P.; Blondel, C.; Laurent, P.; Lebrun, F.; Di Cocco, G.; Malaguti, E.; Gabriele, M.; La Rosa, G.; Segreto, A.; Quadrini, E.; Volkmer, R.

    2003-01-01

    We present an overview of results obtained from IBIS ground calibrations. The spectral and spatial characteristics of the detector planes and surrounding passive materials have been determined through a series of calibration campaigns. Measurements of pixel gain, energy resolution, detection uniformity, efficiency and imaging capability are presented. The key results obtained from the ground calibration have been: - optimization of the instrument tunable parameters, - determination of energy linearity for all detection modes, - determination of energy resolution as a function of energy through the range 20 keV - 3 MeV, - demonstration of imaging capability in each mode, - measurement of intrinsic detector non-uniformity and understanding of the effects of passive materials surrounding the detector plane, and - discovery (and closure) of various leakage paths through the passive shielding system

  20. Gamma counter calibration system

    International Nuclear Information System (INIS)

    1977-01-01

    A method and apparatus are described for the calibration of a gamma radiation measurement instrument to be used over any of a number of different absolute energy ranges. The method includes the steps of adjusting the overall signal gain associated with pulses which are derived from detected gamma rays, until the instrument is calibrated for a particular absolute energy range; then storing parameter settings corresponding to the adjusted overall signal gain, and repeating the process for other desired absolute energy ranges. The stored settings can be subsequently retrieved and reapplied so that test measurements can be made using a selected one of the absolute energy ranges. Means are provided for adjusting the overall signal gain and a specific technique is disclosed for making coarse, then fine adjustments to the signal gain, for rapid convergence of the required calibration settings. (C.F.)

  1. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Hoefert, M.; Nielsen, M.

    1996-01-01

    In 1995 both the Individual Dosimetry and Calibration Sections worked under the condition of a status quo and concentrated fully on the routine part of their work. Nevertheless, the machine for printing the bar code which will be glued onto the film holder and hence identify the people when entering into high radiation areas was put into operation and most of the holders were equipped with the new identification. As far as the Calibration Section is concerned the project of the new source control system that is realized by the Technical Support Section was somewhat accelerated

  2. Radiation Calibration Measurements

    International Nuclear Information System (INIS)

    Omondi, C.

    2017-01-01

    KEBS Radiation Dosimetry mandate are: Custodian of Kenya Standards on Ionizing radiation, Ensure traceability to International System (SI ) and Calibration radiation equipment. RAF 8/040 on Radioisotope applications for troubleshooting and optimizing industrial process established Radiotracer Laboratory objective is to introduce and implement radiotracer technique for problem solving of industrial challenges. Gamma ray scanning technique applied is to Locate blockages, Locate liquid in vapor lines, Locate areas of lost refractory or lining in a pipe and Measure flowing densities. Equipment used for diagnostic and radiation protection must be calibrated to ensure Accuracy and Traceability

  3. Calibrating Legal Judgments

    Directory of Open Access Journals (Sweden)

    Frederick Schauer

    2017-09-01

    Full Text Available Objective to study the notion and essence of legal judgments calibration the possibilities of using it in the lawenforcement activity to explore the expenses and advantages of using it. Methods dialectic approach to the cognition of social phenomena which enables to analyze them in historical development and functioning in the context of the integrity of objective and subjective factors it determined the choice of the following research methods formallegal comparative legal sociological methods of cognitive psychology and philosophy. Results In ordinary life people who assess other peoplersaquos judgments typically take into account the other judgments of those they are assessing in order to calibrate the judgment presently being assessed. The restaurant and hotel rating website TripAdvisor is exemplary because it facilitates calibration by providing access to a raterrsaquos previous ratings. Such information allows a user to see whether a particular rating comes from a rater who is enthusiastic about every place she patronizes or instead from someone who is incessantly hard to please. And even when less systematized as in assessing a letter of recommendation or college transcript calibration by recourse to the decisional history of those whose judgments are being assessed is ubiquitous. Yet despite the ubiquity and utility of such calibration the legal system seems perversely to reject it. Appellate courts do not openly adjust their standard of review based on the previous judgments of the judge whose decision they are reviewing nor do judges in reviewing legislative or administrative decisions magistrates in evaluating search warrant representations or jurors in assessing witness perception. In most legal domains calibration by reference to the prior decisions of the reviewee is invisible either because it does not exist or because reviewing bodies are unwilling to admit using what they in fact know and employ. Scientific novelty for the first

  4. Calibration of scanning Lidar

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  5. Investigation of a zirconia co-fired ceramic calorimetric microsensor for high-temperature flow measurements

    International Nuclear Information System (INIS)

    Lekholm, Ville; Persson, Anders; Klintberg, Lena; Thornell, Greger

    2015-01-01

    This paper describes the design, fabrication and characterization of a flow sensor for high-temperature, or otherwise aggressive, environments, like, e.g. the propulsion system of a small spacecraft. The sensor was fabricated using 8 mol% yttria stabilized zirconia (YSZ8) high-temperature co-fired ceramic (HTCC) tape and screen printed platinum paste. A calorimetric flow sensor design was used, with five 80 µm wide conductors, separated by 160 µm, in a 0.4 mm wide, 0.1 mm deep and 12.5 mm long flow channel. The central conductor was used as a heater for the sensor, and the two adjacent conductors were used to resistively measure the heat transferred from the heater by forced convection. The two outermost conductors were used to study the influence of an auxiliary heat source on the sensor. The resistances of the sensor conductors were measured using four-point connections, as the gas flow rate was slowly increased from 0 to 40 sccm, with different power supplied through the central heater, as well as with an upstream or downstream heater powered. In this study, the thermal and electrical integrability of microcomponents on the YSZ8 substrate was of particular interest and, hence, the influence of thermal and ionic conduction in the substrate was studied in detail. The effect of the ion conductivity of YSZ8 was studied by measuring the resistance of a platinum conductor and the resistance between two adjacent conductors on YSZ8, in a furnace at temperatures from 20 to 930 °C and by measuring the resistance with increasing current through a conductor. With this design, the influence of ion conductivity through the substrate became apparent above 700 °C. The sensitivity of the sensor was up to 1 mΩ sccm −1 in a range of 0–10 sccm. The results show that the signal from the sensor is influenced by the integrated auxiliary heating conductors and that these auxiliary heaters provide a way to balance disturbing heat sources, e.g. thrusters or other

  6. Compatibilidad química del piracetam determinada por calorimetría diferencial de barrido

    Directory of Open Access Journals (Sweden)

    Luis Octavio Martínez Álvarez

    2013-03-01

    Full Text Available Introducción: en la primera etapa de preformulación de un medicamento se seleccionan los excipientes y es importante la realización de los estudios de compatibilidad química entre el ingrediente activo farmacéutico (IFA y excipientes. Una de las técnicas más rápidas para realizar dichos estudios es la Calorimetría diferencial de barrido (DSC, y como técnica complementaria la Termogravimetría (TG. Objetivo: empleando DSC y TG, se realiza un estudio de compatibilidad química entre IFA y excipientes preseleccionados, para comprobar la existencia o no de interacción química. Métodos: el equipo empleado fue el TA3000Mettler, aco­plado a la celda DSC20 y al horno TG50. El IFA utilizado fue Piracetam, y los excipientes: Kollidon VA 64, Estearato de magnesio, Celulosa microcristalina, Polietilenglicol 20 000 y Aerosil. Dichos excipientes se caracterizaron por DSC al igual que el IFA, al cual se le detectó la transición física de fusión. Para el estudio de compatibilidad se prepararon mezclas físicas binarias en una relación de concentración 1:1 Resultados: la figura 1 muestra la detección del punto de fusión por DSC del IFA. Se obtuvieron dos transiciones endotérmicas, comprobándose por TG cuál era la de fusión. La figura 2 muestra los termogramas de las mezclas formadas entre IFA y excipientes. Conclusiones: no se detectó aparición de nuevos picos, por lo que se infiere que no hay incompatibilidad química entre las sustancias estudiadas y se recomienda el uso de los excipientes para el desarrollo de la formulación farmacéutica.

  7. Advances in High Power Calorimetric Matched Loads for Short Pulses and CW Gyrotrons

    International Nuclear Information System (INIS)

    Bin, W.M.; Bruschi, A.; Cirant, S.; Gandini, F.; Granucci, G.; Mellera, V.; Muzzini, V.; Nardone, A.; Sozzi, C.; Spinicchia, N.

    2006-01-01

    The development of high power gyrotrons for plasma physics research needs proper matched and calorimetric loads able to absorb and measure the power, which nowadays is foreseen to be as high as 2 MW during CW operations. To this end IFP/CNR has developed a family of matched loads useful in the mm-wave frequency band for applications ranging from a few ms to CW in pulse length. The different loads in the family, made of an integrating sphere with a partially reflecting coating on the inner wall, are characterized by having the same absorbing geometry for the incoming beam and a different heat removal system for the specific application. Some important advances have been recently achieved from the point of view of the uniformity of power distribution on the absorbing wall and of the load construction. With high precision achieved in the coating thickness a better control of the heating power distribution is possible by proper shaping of the local reflectivity, in addition to the shaping of the mirror dispersing the input beam. A more sophisticated model describing the power distribution has been developed, taking into account a variable thickness of the absorbing coating, the proper shape of the spreading mirror, the frequency of the incoming radiation and the shape of the input beam. Lower coating thickness is shown to be preferable, at equal local reflectivity, from the point of view of a lower peak temperature and thermal stress. The paper describes a load with variable coating thickness along the meridian of the sphere, showing a uniform power deposition on the inner walls. The cooling pipe is completely electroformed on the spherical copper shell, ensuring the maintenance of the correct curvature of the inner surface and a fast heat conduction from the absorbing coating to the water through the thin copper body. For CW use all heated parts of the load must be cooled and this is achieved by 16 electroformed spiral channels. Both short pulse loads (0.1-1 s) and

  8. Le bureau d'études mécaniques du groupe TS-MME

    CERN Document Server

    Menot, C

    2004-01-01

    Le bureau d'études du groupe MME représente le principal support d'ingénierie mécanique pour le LHC et quelques projets autres. Il est constitué de trois sections au mandat distinct. Ses activités couvrent le design des divers équipements : des aimants supraconducteurs du LHC et leur alimentation électrique, le design pour le système vide et de l'instrumentation et calibration de faisceau. Le groupe a aussi en charge le design de tout système se rapportant aux complexes PS et SPS Les principaux sujets présentés dans ce rapport concernent la structure du bureau d'études et son effectif, les ressources à disposition, son domaine d'activité, son mode de fonctionnement, les outils et les méthodologies développés. La coordination entre sections du groupe, qui apportent chacune son expertise, sera mise en évidence. Une vision du futur avec les besoins en ressources liés aux activités vitales pour le CERN est abordée en conclusion.

  9. Paul Celan in Translation: "Du sei wie du"

    Directory of Open Access Journals (Sweden)

    John Felstiner

    1983-09-01

    Full Text Available Translating the lyric poetry of Paul Celan, especially his later poems, carries not only the endemic challenge and difficulty of any verse translation, but the added incentive of doing justice to a writer whose whole recourse after the Holocaust—whose sanctuary, if he was to have any at all—he sought in language itself, specifically in the Muttersprache , the mother tongue that was as well the tongue of those who murdered his mother and father. This essay exposes a process of translating "Du sei wie du" (1970, which perhaps more than any other poem by Celan, at once solicits and defies translation, moving as it does from modern to medieval German, and closing with Hebrew words from Isaiah— a messianic imperative that shows Celan verging as ever on his Jewish identity.

  10. Le parcours migratoire de jeunes ruraux du bled du kif

    Directory of Open Access Journals (Sweden)

    Khalid Mouna

    2015-06-01

    Full Text Available Cet article analyse le parcours migratoire des jeunes ruraux originaires des zones de production du cannabis, jeunes qui cherchent à briser les chaînes de soumission et d’humiliation vécues au quotidien. Pour les jeunes concernés par notre étude, la migration constitue un moyen de s’intégrer dans des réseaux transnationaux et ainsi d’entamer une carrière de beznass (commerçant du cannabis. Ce parcours « initiatique » permet à ces jeunes de revenir au bled avec de nouvelles idées, des moyens accrus, et de jouer un rôle actif dans l’économie locale – qui reste pour eux focalisée sur la production de cannabis, cette dernière restant néanmoins officiellement interdite.

  11. Bassins versants du Loup, de la Cagne et du Malvan

    OpenAIRE

    Lepère, Cédric; Lautier, Laurence; Pellegrino, Emmanuel

    2013-01-01

    Identifiant de l'opération archéologique : 8453 Date de l'opération : 2007 (PC) ; 2007 (PI) Inventeur(s) : Lepère Cédric (AUT) ; Lautier Laurence (AUT) ; Pellegrino Emmanuel (AUT) Une campagne de prospection inventaire a été effectuée pendant trois mois, dans les bassins-versants de la Cagne, du Loup et du Malvan qui regroupent les communes de Cagnes-sur-Mer, Villeneuve-Loubet, La Colle-sur-Loup, Saint-Paul-de-Vence, Vence, Saint-Jeannet, Bezaudun, Tourrettes-sur-Loup, Roquefort-les-Pins, Le ...

  12. Calorimetric determination of the enthalpy of 1-butyl-3-methylimidazolium bromide synthesis: a key quantity in thermodynamics of ionic liquids.

    Science.gov (United States)

    Paulechka, Yauheni U; Kabo, Andrey G; Blokhin, Andrey V

    2009-11-05

    The enthalpy of the 1-butyl-3-methylimidazolium bromide [C(4)mim]Br ionic liquid synthesis reaction 1-methylimidazole (liq) + 1-bromobutane (liq) --> [C(4)mim]Br (liq) was determined in a homemade small-volume isoperibol calorimeter to be Delta(r)H degrees (298) = -87.7 +/- 1.6 kJ x mol(-1). The activation energy for this reaction in a homogeneous system E(A) = 73 +/- 4 kJ x mol(-1) was found from the results of calorimetric measurements. The formation enthalpies for the crystalline and liquid [C(4)mim]Br were determined from the calorimetric data: Delta(f)H degrees (298)(cr) = -178 +/- 5 kJ x mol(-1) and Delta(f)H degrees (298)(liq) = -158 +/- 5 kJ x mol(-1). The ideal-gas formation enthalpy of this compound Delta(f)H degrees (298)(g) = 16 +/- 7 kJ x mol(-1) was calculated using the methods of quantum chemistry and statistical thermodynamics. The vaporization enthalpy of [C(4)mim]Br, Delta(vap)H degrees (298) = 174 +/- 9 kJ x mol(-1), was estimated from the experimental and calculated formation enthalpies. It was demonstrated that vapor pressure of this ionic liquid cannot be experimentally determined.

  13. Marche du foncier urbain et promotion du logement au Benin ...

    African Journals Online (AJOL)

    Le marché du foncier urbain au Bénin est un secteur qui met en jeu l'intervention de plusieurs acteurs publics et privés mais également de l'informel. La notion de « foncier urbain » utilisée dans cet article englobe les acceptions et les utilisations faites en architecture, en urbanisme, en aménagement et en gestion urbaine.

  14. Gestion du parc agroforestier du terroir de Vipalogo (Burkina Faso ...

    African Journals Online (AJOL)

    Au Burkina Faso, l'arbre rural fait partie des systèmes de production. Le choix des espèces, leur densité, les modes de gestion ainsi que les besoins à satisfaire, obéissent à des critères propres aux producteurs. C'est pour comprendre ces logiques paysannes de la gestion du parc agroforestier que la présente étude a été ...

  15. Malformations du tube neural en chirurgie pediatrique du chu de ...

    African Journals Online (AJOL)

    encéphalocèle et 6 cas de sipina bifida. La cure chirurgicale a été le principal mode de prise en charge des patients. Seuls 91,38% des cas ont été opérés. Pour toutes les malformations du tube neural, nous avons enregistré 7 décès dont 2 décès ...

  16. ECAL Energy Flow Calibration

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    My talk will be covering my work as a whole over the course of the semester. The focus will be on using energy flow calibration in ECAL to check the precision of the corrections made by the light monitoring system used to account for transparency loss within ECAL crystals due to radiation damage over time.

  17. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  18. Calibration bench of flowmeters

    International Nuclear Information System (INIS)

    Bremond, J.; Da Costa, D.; Calvet, A.; Vieuxmaire, C.

    1966-01-01

    This equipment is devoted to the comparison of signals from two turbines installed in the Cabri experimental loop. The signal is compared to the standard turbine. The characteristics and the performance of the calibration bench are presented. (A.L.B.)

  19. Calibration of farmer dosemeters

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Anwar, K.; Arshed, W.; Mubarak, M.A.; Orfi, S.D.

    1984-08-01

    The Farmer Dosemeters of Atomic Energy Medical Centre (AEMC) Jamshoro were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) at PINSTECH, using the NPL Secondary Standard Therapy level X-ray exposure meter. The results are presented in this report. (authors)

  20. Physiotherapy ultrasound calibrations

    International Nuclear Information System (INIS)

    Gledhill, M.

    1996-01-01

    Calibration of physiotherapy ultrasound equipment has long been a problem. Numerous surveys around the world over the past 20 years have all found that only a low percentage of the units tested had an output within 30% of that indicatd. In New Zealand, a survey carried out by the NRL in 1985 found that only 24% had an output, at the maximum setting, within + or - 20% of that indicated. The present performance Standard for new equipment (NZS 3200.2.5:1992) requires that the measured output should not deviate from that indicated by more than + or - 30 %. This may be tightened to + or - 20% in the next few years. Any calibration is only as good as the calibration equipment. Some force balances can be tested with small weights to simulate the force exerted by an ultrasound beam, but with others this is not possible. For such balances, testing may only be feasible with a calibrated source which could be used like a transfer standard. (author). 4 refs., 3 figs

  1. NVLAP calibration laboratory program

    Energy Technology Data Exchange (ETDEWEB)

    Cigler, J.L.

    1993-12-31

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST).

  2. NVLAP calibration laboratory program

    International Nuclear Information System (INIS)

    Cigler, J.L.

    1993-01-01

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST)

  3. Gamma ray calibration system

    International Nuclear Information System (INIS)

    Rosauer, P.J.; Flaherty, J.J.

    1981-01-01

    This invention is in the field of gamma ray inspection devices for tubular products and the like employing an improved calibrating block which prevents the sensing system from being overloaded when no tubular product is present, and also provides the operator with a means for visually detecting the presence of wall thicknesses which are less than a required minimum. (author)

  4. The development of an electrically compensated differential calorimeter for the measurement of in-pile heat evolution (1962); Etude et realisation d'un calorimetre differentiel a compensation electrique pour la mesure des echaufpements en pile (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Ayela, F; Derrien, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    It has been possible with the calorimeter of which we give the principle and details in the present report, to determine the calorific power produced by nuclear radiation in a given sample using simple electrical measurement. It also renders unnecessary all absolute measurements of temperature, all possible calibration, and the use of the thermal or thermoelectric constants of the constituent elements. The possible uses of the apparatus are fairly varied, as shown by the first in-pile experiments which we have carried out and for which we give results. (authors) [French] Le calorimetre, dont nous decrivons le principe et les details dans le present rapport, nous permet de determiner, par de simples mesures electriques, la puissance calorifique liberee par les rayonnements nucleaires dans un echantillon donne. Il nous affranchit aussi, de toute mesure absolue de temperature, de tout etalonnage prealable, et de l'utilisation des constantes thermiques ou thermoelectriques de ses elements constitutifs. Les possibilites d'emploi de l'appareil sont assez variees comme nous le montrent les premiers essais que nous avons effectues en pile et dont nous donnons les resultats. (auteurs)

  5. Determination of electronic stopping powers of 0.05–1 MeV/u {sup 131}Xe ions in C-, Ni- and Au-absorbers with calorimetric low temperature detectors

    Energy Technology Data Exchange (ETDEWEB)

    Echler, A., E-mail: artur.echler@iamp.physik.uni-giessen.de [GSI Helmholtz Center for Heavy Ion Research, Darmstadt (Germany); Institute for Atomic and Molecular Physics, University of Giessen (Germany); Institute for Physics, University of Mainz (Germany); Egelhof, P.; Grabitz, P. [GSI Helmholtz Center for Heavy Ion Research, Darmstadt (Germany); Institute for Physics, University of Mainz (Germany); Kettunen, H. [Department of Physics, University of Jyväskylä (Finland); Kraft-Bermuth, S. [Institute for Atomic and Molecular Physics, University of Giessen (Germany); Laitinen, M. [Department of Physics, University of Jyväskylä (Finland); Müller, K. [Institute for Atomic and Molecular Physics, University of Giessen (Germany); Rossi, M.; Trzaska, W.H.; Virtanen, A. [Department of Physics, University of Jyväskylä (Finland)

    2017-01-15

    A new experimental system for precise determination of electronic stopping powers of heavy ions has been set up at the accelerator laboratory of the University of Jyväskylä. The new setup, combining an established B-ToF system and an array of calorimetric low temperature detectors (CLTDs), has been used for the determination of electronic stopping powers of 0.05–1 MeV/u {sup 131}Xe ions in carbon, nickel and gold. Thereby advantage of the improved linearity and energy resolution of CLTDs as compared to the previously used ionization detector was taken to reduce energy calibration errors and to increase sensitivity for the energy loss determination, in particular at very low energies. The total uncertainties of 3–4% for C- and Ni-targets, and 5–7% for Au-targets, respectively, are dominated by the target properties, i.e. thickness determination and inhomogeneities. The results are compared to data from literature and to predictions of different theoretical computer codes. In the high energy part of the examined energy range the results are in good agreement with previously published data, while new stopping power data for very heavy ions in different Z{sub 2}-materials have been obtained at lower energies. Moreover, unexpectedly strong channeling effects for the transmission of the {sup 131}Xe ions in thin, partly polycrystalline nickel and gold target foils have been observed and investigated.

  6. PLEIADES ABSOLUTE CALIBRATION : INFLIGHT CALIBRATION SITES AND METHODOLOGY

    Directory of Open Access Journals (Sweden)

    S. Lachérade

    2012-07-01

    Full Text Available In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station and Oceans (Calibration over molecular scattering or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  7. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John F. Schabron; Joseph F. Rovani; Susan S. Sorini

    2007-03-31

    The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005, requires that calibration of mercury continuous emissions monitors (CEMs) be performed with NIST-traceable standards. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The traceability protocol will be written by EPA. Traceability will be based on the actual analysis of the output of each calibration unit at several concentration levels ranging from about 2-40 ug/m{sup 3}, and this analysis will be directly traceable to analyses by NIST using isotope dilution inductively coupled plasma/mass spectrometry (ID ICP/MS) through a chain of analyses linking the calibration unit in the power plant to the NIST ID ICP/MS. Prior to this project, NIST did not provide a recommended mercury vapor pressure equation or list mercury vapor pressure in its vapor pressure database. The NIST Physical and Chemical Properties Division in Boulder, Colorado was subcontracted under this project to study the issue in detail and to recommend a mercury vapor pressure equation that the vendors of mercury vapor pressure calibration units can use to calculate the elemental mercury vapor concentration in an equilibrium chamber at a particular temperature. As part of this study, a preliminary evaluation of calibration units from five vendors was made. The work was performed by NIST in Gaithersburg, MD and Joe Rovani from WRI who traveled to NIST as a Visiting Scientist.

  8. Self consistently calibrated photopyroelectric calorimeter for the high resolution simultaneous absolute measurement of the specific heat and of the thermal conductivity

    Directory of Open Access Journals (Sweden)

    U. Zammit

    2012-03-01

    Full Text Available High temperature resolution study of the specific heat and of the thermal conductivity over the smecticA-nematic and nematic-isotropic phase transitions in octylcynobephenyl liquid crystal using a new photopyroelectric calorimetry configuration are reported, where, unlike previously adopted ones, no calibration is required other than the procedure used during the actual measurement. This makes photopyroelectric calorimetry suitable for “absolute” measurements of the thermal parameters like most other existing conventional calorimetric techniques where, however, the thermal conductivity cannot be measured.

  9. L’Harmonie du monde

    Directory of Open Access Journals (Sweden)

    Martine Clouzot

    2003-11-01

    Full Text Available La Bourgogne est particulièrement bien présente et représentée dans l’exposition sur la musique et ses représentations au Moyen Âge organisée par Isabelle Marchesin (université de Poitiers, Christine Laloue (conservatrice du Patrimoine au Musée et Martine Clouzot (université de Bourgogne, au Musée de la Musique à Paris du 26 mars au 27 juin 2004. En Côte-d’Or, à Dijon, la Bibliothèque municipale a donné son accord officiel pour le prêt de la Bible d’Etienne Harding, les Moralia in Job et u...

  10. Les vicissitudes du fret ferroviaire

    OpenAIRE

    DABLANC, L

    2010-01-01

    Dans beaucoup de pays européens, et plus encore en Amérique du Nord et en Asie, le transport de marchandises par le train a augmenté depuis dix ans. Cette activité réduit la part des marchandises acheminées par la route et contribue ainsi au développement durable : un camion émet 8 à 30 fois plus de dioxyde de carbone que le train, pour une distance et une quantité transportée équivalentes. Pourtant, la France a raté ce renouveau. Filiale du groupe public SNCF, la Société Fret SNCF, qui assur...

  11. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Mortensen, Niels Gylling; Hansen, Jens Carsten

    2007-01-01

    A field calibration method and results are described along with the experience gained with the method. The cup anemometers to be calibrated are mounted in a row on a 10-m high rig and calibrated in the free wind against a reference cup anemometer. The method has been reported [1] to improve...... the statistical bias on the data relative to calibrations carried out in a wind tunnel. The methodology is sufficiently accurate for calibration of cup anemometers used for wind resource assessments and provides a simple, reliable and cost-effective solution to cup anemometer calibration, especially suited...

  12. L'energie du moustique

    CERN Document Server

    Augereau, J F

    2002-01-01

    ENSEMBLE DE QUATRE ARTICLES - LARGE HADRON COLLIDER: Le dernier accelerateur de particules du CERN, le LEP, produisait des faisceaux d'electrons de 100 GeV chacun. Le LHC, qui accelere des faisceaux de protons, leur communiquera une energie de 7 TeV chacun. Une energie a la fois colossale et derisoire. Un TeV represente a peu pres l'energie cinetique d'un moustique (1/2 page).

  13. Revision des Symphurus du Siboga

    NARCIS (Netherlands)

    Chabanaud, Paul

    1955-01-01

    Ce m’est un devoir particulièrement agréable que de saisir l’occasion de ce petit mémoire pour remercier M. L. F. DE BEAUFORT, M. H. ENGEL, Directeur du Zoologisch Museum, ainsi que M. J. J. HOEDEMAN de l’accueil qu’à diverses reprises, j’ai reçu de leur part, au Zoölogisch Museum, et aussi des

  14. Actes des 5èmes Journées Scientifiques du GDR3544 Sciences du Bois. Journées Annuelles du GDR 3544 Sciences du Bois

    OpenAIRE

    CHAPLAIN, Myriam; CARE, Sabine; GRIL, Joseph

    2016-01-01

    Le Groupement de Recherche en Sciences du bois (GDR3544 Sciences du Bois) a été créé en 2012 par le CNRS et renouvelé en 2016 pour 5 ans. La mission de ce groupement est : (1) de structurer la recherche sur le bois en France pour lui donner une visibilité nationale, (2) de contribuer au développement de la formation en sciences du bois et (3) de servir de relai aux réseaux internationaux de sciences du bois. Les 5èmes journées annuelles du GDR Bois ont été organisées à Bordeaux, au domaine du...

  15. Original Paper Performances comparées du HDL-cholestérol et du ...

    African Journals Online (AJOL)

    CT/HDL-C) et du HDL-Cholestérol est le meilleur prédicteur du SMet chez les adultes béninois. .... (Canada) et du. Ministère de la Santé du Bénin. Le consentement éclairé écrit a été obtenu de chaque participant avant leur recrutement dans.

  16. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  17. 35 Typologie des eaux de surface du bassin du Sebou par multi ...

    African Journals Online (AJOL)

    PR BOKO

    2Service de protection de la qualité de l'eau, Agence du Bassin Hydraulique du ... pour montrer l'évolution de la qualité biologique des eaux de surface du ..... Biological Indicators of Freshwater Pollution and Environmental Management,.

  18. Régionalisation du recrutement du personnel de santé au Burkina ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Régionalisation du recrutement du personnel de santé au Burkina Faso ... le ministère a adopté une politique de recrutement régionalisé de certaines catégories du ... de comprendre le contexte dans lequel une telle stratégie a été formulée, ...

  19. Comparison of Calibration of Sensors Used for the Quantification of Nuclear Energy Rate Deposition

    Energy Technology Data Exchange (ETDEWEB)

    Brun, J.; Reynard-Carette, C. [Aix Marseille Universite, CNRS, Universite de Toulon, IM2NP UMR 7334, 13397, Marseille (France); Tarchalski, M.; Pytel, K. [National Centre for Nuclear Research A. Soltana 7, 05-400 Swierk (Poland); Lyoussi, A.; Fourmentel, D.; Villard, J.F. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France); Jagielski, J. [National Centre for Nuclear Research A. Soltana 7, 05-400 Swierk (Poland); Institute of Electronic Materials Technolgy, Wolczynska 133, 01-919 Warszawa (Poland)

    2015-07-01

    This present work deals with a collaborative program called GAMMA-MAJOR 'Development and qualification of a deterministic scheme for the evaluation of GAMMA heating in MTR reactors with exploitation as example MARIA reactor and Jules Horowitz Reactor' between the National Centre for Nuclear Research of Poland, the French Atomic Energy and Alternative Energies Commission and Aix Marseille University. One of main objectives of this program is to optimize the nuclear heating quantification thanks to calculation validated from experimental measurements of radiation energy deposition carried out in irradiation reactors. The quantification of the nuclear heating is a key data especially for the thermal, mechanical design and sizing of irradiation experimental devices in specific irradiated conditions and locations. The determination of this data is usually performed by differential calorimeters and gamma thermometers such as used in the experimental multi-sensors device called CARMEN 'Calorimetric en Reacteur et Mesures des Emissions Nucleaires'. In the framework of the GAMMA-MAJOR program a new calorimeter was designed for the nuclear energy deposition quantification. It corresponds to a single-cell calorimeter and it is called KAROLINA. This calorimeter was recently tested during an irradiation campaign inside MARIA reactor in Poland. This new single-cell calorimeter differs from previous CALMOS or CARMEN type differential calorimeters according to three main points: its geometry, its preliminary out-of-pile calibration, and its in-pile measurement method. The differential calorimeter, which is made of two identical cells containing heaters, has a calibration method based on the use of steady thermal states reached by simulating the nuclear energy deposition into the calorimeter sample by Joule effect; whereas the single-cell calorimeter, which has no heater, is calibrated by using the transient thermal response of the sensor (heating and cooling

  20. Comparison of Calibration of Sensors Used for the Quantification of Nuclear Energy Rate Deposition

    International Nuclear Information System (INIS)

    Brun, J.; Reynard-Carette, C.; Tarchalski, M.; Pytel, K.; Lyoussi, A.; Fourmentel, D.; Villard, J.F.; Jagielski, J.

    2015-01-01

    This present work deals with a collaborative program called GAMMA-MAJOR 'Development and qualification of a deterministic scheme for the evaluation of GAMMA heating in MTR reactors with exploitation as example MARIA reactor and Jules Horowitz Reactor' between the National Centre for Nuclear Research of Poland, the French Atomic Energy and Alternative Energies Commission and Aix Marseille University. One of main objectives of this program is to optimize the nuclear heating quantification thanks to calculation validated from experimental measurements of radiation energy deposition carried out in irradiation reactors. The quantification of the nuclear heating is a key data especially for the thermal, mechanical design and sizing of irradiation experimental devices in specific irradiated conditions and locations. The determination of this data is usually performed by differential calorimeters and gamma thermometers such as used in the experimental multi-sensors device called CARMEN 'Calorimetric en Reacteur et Mesures des Emissions Nucleaires'. In the framework of the GAMMA-MAJOR program a new calorimeter was designed for the nuclear energy deposition quantification. It corresponds to a single-cell calorimeter and it is called KAROLINA. This calorimeter was recently tested during an irradiation campaign inside MARIA reactor in Poland. This new single-cell calorimeter differs from previous CALMOS or CARMEN type differential calorimeters according to three main points: its geometry, its preliminary out-of-pile calibration, and its in-pile measurement method. The differential calorimeter, which is made of two identical cells containing heaters, has a calibration method based on the use of steady thermal states reached by simulating the nuclear energy deposition into the calorimeter sample by Joule effect; whereas the single-cell calorimeter, which has no heater, is calibrated by using the transient thermal response of the sensor (heating and cooling

  1. La disparition du temps en gravitation quantique

    OpenAIRE

    Saint-Ours, Alexis de

    2012-01-01

    Le but de ce travail est d’examiner l’incidence philosophique de la gravitation quantique sur le concept de temps. Je cherche à montrer qu’elle conduit à une disparition du temps comme dimension et ouvre la voie à une compréhension du temps comme variation et même à l’idée de variation pure. En l’absence de temps mécanique, il est cependant possible de définir un temps d’origine thermodynamique. Je montre en quoi cette dissociation du temps mécanique et du temps thermodynamique, fait écho à l...

  2. Au fil du temps (1976 ou la loi du seuil

    Directory of Open Access Journals (Sweden)

    Isabelle Singer

    2010-04-01

    Full Text Available Ayant choisi de vivre dans un camion, les héros d’Au fil du temps (film de Wim Wenders de 1976 font du seuil une expérience particulière. Celle de la rupture avec toute idée de foyer et celle du refus d’appartenance à la terre natale, cette terre allemande traversée par une frontière le long de laquelle ils vont voyager, et qui les renvoie à chaque instant aux traumatismes de l’Histoire. Sur le pare-brise du camion, l’extérieur (campagnes indifférenciées, villes à l’abandon… et l’intérieur se superposent. Au fil du temps questionne le paysage : il s’agit d’en décoller un à un les mythes qui le recouvrent. L’image alors n’est plus surface mais volume à traverser, à lacérer et découvrir ce qui est tissé dans le paysage. La démarche de Wenders est alors proche de celle d’un de ses contemporains : Anselm Kiefer. Le paysage allemand provoque le rejet parce qu’il y a là toujours plus que le visible : des strates et des strates de culpabilité que le mythe - et c’est sa fonction - a recouvert. Et qu’il s’agira ici, de soulever. Le choix du nomadisme, c’est celui d’un état de l’humanité antérieur à l’idée de patrie. Et c’est aussi celui de la solitude, comme prix à payer à ce refus d’appartenance et à cette mise à jour des mythes. L’appartenance à la terre allemande et à son Histoire est profondément problématique parce que les pères sont fondamentalement coupables. On se reconnaîtra alors des pères de substitution : des pères de cinéma (Nicholas Ray ou Fritz Lang. Et l’on substituera l’Histoire du cinéma à l’Histoire. Bruno est réparateur ambulant de projecteurs et Au fil du temps dressera, au gré de ses pérégrinations, un état des lieux du cinéma allemand des années soixante-dix : déliquescent, colonisé par les images hollywoodiennes. Il faut que cela change : état du cinéma ; état des protagonistes solitaires en quête d’une identit

  3. Thermogravimetric and calorimetric characteristics during co-pyrolysis of municipal solid waste components.

    Science.gov (United States)

    Ansah, Emmanuel; Wang, Lijun; Shahbazi, Abolghasem

    2016-10-01

    The thermogravimetric and calorimetric characteristics during pyrolysis of wood, paper, textile and polyethylene terephthalate (PET) plastic in municipal solid wastes (MSW), and co-pyrolysis of biomass-derived and plastic components with and without torrefaction were investigated. The active pyrolysis of the PET plastic occurred at a much higher temperature range between 360°C and 480°C than 220-380°C for the biomass derived components. The plastic pyrolyzed at a heating rate of 10°C/min had the highest maximum weight loss rate of 18.5wt%/min occurred at 420°C, followed by 10.8wt%/min at 340°C for both paper and textile, and 9.9wt%/min at 360°C for wood. At the end of the active pyrolysis stage, the final mass of paper, wood, textile and PET was 28.77%, 26.78%, 21.62% and 18.31%, respectively. During pyrolysis of individual MSW components at 500°C, the wood required the least amount of heat at 665.2J/g, compared to 2483.2J/g for textile, 2059.4J/g for paper and 2256.1J/g for PET plastic. The PET plastic had much higher activation energy of 181.86kJ/mol, compared to 41.47kJ/mol for wood, 50.01kJ/mol for paper and 36.65kJ/mol for textile during pyrolysis at a heating rate of 10°C/min. H2O and H2 peaks were observed on the MS curves for the pyrolysis of three biomass-derived materials but there was no obvious H2O and H2 peaks on the MS curves of PET plastic. There was a significant interaction between biomass and PET plastic during co-pyrolysis if the biomass fraction was dominant. The amount of heat required for the co-pyrolysis of the biomass and plastic mixture increased with the increase of plastic mass fraction in the mixture. Torrefaction at a proper temperature and time could improve the grindability of PET plastic. The increase of torrefaction temperature and time did not affect the temperature where the maximum pyrolytic rates occurred for both biomass and plastic but decreased the maximum pyrolysis rate of biomass and increased the maximum pyrolysis

  4. MAVEN SEP Calibrated Data Bundle

    Data.gov (United States)

    National Aeronautics and Space Administration — The maven.sep.calibrated Level 2 Science Data Bundle contains fully calibrated SEP data, as well as the raw count data from which they are derived, and ancillary...

  5. Determination of Fragility in Organic Small Molecular Glass Forming Liquids: Comparison of Calorimetric and Spectroscopic Data and Commentary on Pharmaceutical Importance.

    Science.gov (United States)

    Chakravarty, Paroma; Pandya, Keyur; Nagapudi, Karthik

    2018-03-05

    The fragility index ( m) and conversely the strength parameter ( D) are widely used to categorize glass forming liquids and are used to characterize temperature dependency of viscosity and relaxation time as the supercooled liquid approaches glass transition. The currently used calorimetric methods in pharmaceutical literature lead to wide variability in measured values of m. In this work, a modulated differential scanning calorimetry (DSC) method is introduced that can directly determine m with minimal variability. Although calorimetric fragility is easy to measure due to availability and ease of use of DSC, there is no correlation between calorimetric and dielectric fragility (calculated spectroscopically from relaxation times). In addition, there is also no correlation between calorimetric fragility and the so-called "thermodynamic fragility" that can be calculated using only thermodynamic parameters. No relationship can be found between the crystallization propensity in the supercooled liquid state and D. However, the crystallization propensity shows a reasonable correlation with the Kohlrausch distribution parameter β k , which defines the breadth of the relaxation time distribution.

  6. Isothermal titration calorimetric studies of the acid-base properties of poly(N-isopropylacrylamide-co-4-vinylpyridine) cationic polyelectrolyte colloidal microgels

    International Nuclear Information System (INIS)

    Seidel, J.; Pinkrah, V.T.; Mitchell, J.C.; Chowdhry, B.Z.; Snowden, M.J.

    2004-01-01

    Isothermal titration calorimetry (ITC) and potentiometric titration were used to study the protonation properties of the 4-vinylpyridine (4-VP) moiety in cationic poly(N-isopropylacrylamide-co-4-vinylpyridine) colloidal microgels [poly(NIPAM-co-4-VP)]. Calorimetric pH titrations were performed using microgels of different 4-VP content and the influence of ionic strength and counter ions have been examined. The calorimetric titration output consists of several thermal contributions reflecting the complex nature of the interactions in the aqueous microgel dispersions. In contrast to the potentiometric results, the calorimetric titration data could not be completely described by a theoretical model solely taking into account protonation equilibria. Deviations from the proposed model correlate with swelling or shrinking of the gel particles. The calorimetric results also reveal a pronounced counter-ion effect of perchlorate compared to chloride ions. In the presence of perchlorate ions, small secondary thermal effects accompany protonation of the 4-VP moiety due, in part, to kinetically limited conformational changes in the co-polymer microgel

  7. Ultrasonic calibration assembly

    International Nuclear Information System (INIS)

    1981-01-01

    Ultrasonic transducers for in-service inspection of nuclear reactor vessels have several problems associated with them which this invention seeks to overcome. The first is that of calibration or referencing a zero start point for the vertical axis of transducer movement to locate a weld defect. The second is that of verifying the positioning (vertically or at a predetermined angle). Thirdly there is the problem of ascertaining the speed per unit distance in the operating medium of the transducer beam prior to the actual inspection. The apparatus described is a calibration assembly which includes a fixed, generally spherical body having a surface for reflecting an ultrasonic beam from one of the transducers which can be moved until the reflection from the spherical body is the highest amplitude return signal indicating radial alignment from the body. (U.K.)

  8. Travelling gradient thermocouple calibration

    International Nuclear Information System (INIS)

    Broomfield, G.H.

    1975-01-01

    A short discussion of the origins of the thermocouple EMF is used to re-introduce the idea that the Peltier and Thompson effects are indistinguishable from one another. Thermocouples may be viewed as devices which generate an EMF at junctions or as integrators of EMF's developed in thermal gradients. The thermal gradient view is considered the more appropriate, because of its better accord with theory and behaviour, the correct approach to calibration, and investigation of service effects is immediately obvious. Inhomogeneities arise in thermocouples during manufacture and in service. The results of travelling gradient measurements are used to show that such effects are revealed with a resolution which depends on the length of the gradient although they may be masked during simple immersion calibration. Proposed tests on thermocouples irradiated in a nuclear reactor are discussed

  9. Mesoscale hybrid calibration artifact

    Science.gov (United States)

    Tran, Hy D.; Claudet, Andre A.; Oliver, Andrew D.

    2010-09-07

    A mesoscale calibration artifact, also called a hybrid artifact, suitable for hybrid dimensional measurement and the method for make the artifact. The hybrid artifact has structural characteristics that make it suitable for dimensional measurement in both vision-based systems and touch-probe-based systems. The hybrid artifact employs the intersection of bulk-micromachined planes to fabricate edges that are sharp to the nanometer level and intersecting planes with crystal-lattice-defined angles.

  10. Calibration of germanium detectors

    International Nuclear Information System (INIS)

    Bjurman, B.; Erlandsson, B.

    1985-01-01

    This paper describes problems concerning the calibration of germanium detectors for the measurement of gamma-radiation from environmental samples. It also contains a brief description of some ways of reducing the uncertainties concerning the activity determination. These uncertainties have many sources, such as counting statistics, full energy peak efficiency determination, density correction and radionuclide specific-coincidence effects, when environmental samples are investigated at close source-to-detector distances

  11. Calibration of hydrometers

    Science.gov (United States)

    Lorefice, Salvatore; Malengo, Andrea

    2006-10-01

    After a brief description of the different methods employed in periodic calibration of hydrometers used in most cases to measure the density of liquids in the range between 500 kg m-3 and 2000 kg m-3, particular emphasis is given to the multipoint procedure based on hydrostatic weighing, known as well as Cuckow's method. The features of the calibration apparatus and the procedure used at the INRiM (formerly IMGC-CNR) density laboratory have been considered to assess all relevant contributions involved in the calibration of different kinds of hydrometers. The uncertainty is strongly dependent on the kind of hydrometer; in particular, the results highlight the importance of the density of the reference buoyant liquid, the temperature of calibration and the skill of operator in the reading of the scale in the whole assessment of the uncertainty. It is also interesting to realize that for high-resolution hydrometers (division of 0.1 kg m-3), the uncertainty contribution of the density of the reference liquid is the main source of the total uncertainty, but its importance falls under about 50% for hydrometers with a division of 0.5 kg m-3 and becomes somewhat negligible for hydrometers with a division of 1 kg m-3, for which the reading uncertainty is the predominant part of the total uncertainty. At present the best INRiM result is obtained with commercially available hydrometers having a scale division of 0.1 kg m-3, for which the relative uncertainty is about 12 × 10-6.

  12. Observation models in radiocarbon calibration

    International Nuclear Information System (INIS)

    Jones, M.D.; Nicholls, G.K.

    2001-01-01

    The observation model underlying any calibration process dictates the precise mathematical details of the calibration calculations. Accordingly it is important that an appropriate observation model is used. Here this is illustrated with reference to the use of reservoir offsets where the standard calibration approach is based on a different model to that which the practitioners clearly believe is being applied. This sort of error can give rise to significantly erroneous calibration results. (author). 12 refs., 1 fig

  13. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  14. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ghezzehej, T.

    2004-01-01

    The purpose of this model report is to document the calibrated properties model that provides calibrated property sets for unsaturated zone (UZ) flow and transport process models (UZ models). The calibration of the property sets is performed through inverse modeling. This work followed, and was planned in, ''Technical Work Plan (TWP) for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Sections 1.2.6 and 2.1.1.6). Direct inputs to this model report were derived from the following upstream analysis and model reports: ''Analysis of Hydrologic Properties Data'' (BSC 2004 [DIRS 170038]); ''Development of Numerical Grids for UZ Flow and Transport Modeling'' (BSC 2004 [DIRS 169855]); ''Simulation of Net Infiltration for Present-Day and Potential Future Climates'' (BSC 2004 [DIRS 170007]); ''Geologic Framework Model'' (GFM2000) (BSC 2004 [DIRS 170029]). Additionally, this model report incorporates errata of the previous version and closure of the Key Technical Issue agreement TSPAI 3.26 (Section 6.2.2 and Appendix B), and it is revised for improved transparency

  15. Contribution to the micro-calorimetric study of the characteristics of radio-elements and to their qualitative and quantitative analysis; Contribution a l'etude microcalorimetrique des caracteristiques des radio-elements et a leurs analyses qualitative et quantitative

    Energy Technology Data Exchange (ETDEWEB)

    Ozias, Y [Centre de Production de Plutonium de Marcoule, 30 (France)

    1964-10-01

    The principle of this study consists in using the E. CALVET microcalorimeter for recording the energy flux emitted by radio-elements as a function of time, and in determining from this curve either their characteristics (half-life and radiation energy), or the composition of a mixture of radio-elements. In the first part the theoretical relationships describing radioactivity have been adapted to the microcalorimetric study. In the second part an experimental determination has been made using the E. CALVET microcalorimeter of the characteristics of various radio-elements, yttrium 90, phosphorus 32, sulphur 35, iodine 131, etc and of their mixtures. In particular a study has been made of the isotopic analysis of a {sup 239}Pu - {sup 240}Pu mixture, sometimes in the presence of {sup 241}Pu. The microcalorimetric method is not as sensitive as conventional counting methods, its limit appears to be at the present about 1 micro-watt for the apparatus used, it is however the most direct method in the case of emitters of weakly absorbed radiation ({alpha} and {beta}). For the {gamma} emitters only a part of the energy is absorbed by the walls of the container. The determination of their characteristics and of their masses in the mixtures depends neither on the shape, on the dilution or even less on the auto-absorption of the source. For high activity samples this auto-absorption is the cause of great difficulties in conventional methods which complicate the operations: divisions, dissolutions, dilutions, all of which are liable to introduce errors. The calorimetric method makes it possible to work on the untreated sample. All these measurements have been carried out using the conventional E CALVET calorimeter; to carry out an exact measurement of the energy due to {gamma} radiation, however, it is necessary to build special apparatus with a lead block the size of which is given by the author's calculations. The calorimetric method makes it possible to attain an accuracy

  16. Determination of tritium by counting; Dosage du tritium par comptage

    Energy Technology Data Exchange (ETDEWEB)

    Schott, R; Froment, G; Pinson, J; Genty, C [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1968-07-01

    Ionisation chamber assay of tritium in any gaseous mixture is a simple, fast and accurate method. We used the method of relative determination by comparison to a standard rather than the method of absolute assay in which case the constants are known with too little accuracy. The efficiency of the chamber was studied in connection to the pressure inside the chamber and its total volume. The calibration is linear in the range we are taking into account (1 to 80 millicuries). The reproducibility of the method is good: 13 runs gave a coefficient of variation of 1.6 per cent. The relative accuracy was found equal to {+-} 1.3 per cent. To end the paper, we describe in detail the apparatus and the ways of proceedings. (authors) [French] Le comptage du tritium par chambre d'ionisation est une methode simple, rapide et precise pour determiner la teneur en tritium d'un melange gazeux quelconque. Nous avons prefere utiliser la methode de determination relative par rapport a un etalon car, dans le cas d'une determination absolue, les constantes sont connues avec une trop grande incertitude. L'efficacite de la chambre a ete etudiee en fonction de la variation de la pression d'argon a l'interieur de la chambre et du volume total, de cette derniere. L'etalonnage s'est revele lineaire dans le domaine de mesures qui nous interessaient (1 a 80 millicuries). La reproductibillte de la methode est tres bonne, le coefficient de variation pour une serie de 13 essais etant de 1,6 pour cent, quant a la precision relative, elle a ete evaluee a {+-} 1,3 pour cent. Pour terminer, nous donnons une description detaillee de l'appareillage utilise et du mode operatoire suivi. (auteurs)

  17. Calibration of the cameras of the H.E.S.S. {gamma}-ray astronomy experiment and observations of the Galactic Centre above 100 GeV; Etalonnage des cameras de l'experience d'astronomie {gamma} H.E.S.S. et observations du centre galactique au-dela de 100 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Rolland, L

    2005-05-15

    The H.E.S.S. experiment (High Energy Stereoscopic System) consists of four imaging atmospheric Cherenkov telescopes to study the southern astrophysical sources above 100 GeV. This thesis presents the detector as well as the analysis chain. The calibration methods are described in details and the systematic errors on the image amplitude are derived. Then, an analysis based on a semi-analytical model of the electromagnetic shower development in the atmosphere is presented. Tools to reconstruct the energy spectrum and the morphology of the very high energy {gamma}-ray sources are presented and applied to the Crab Nebula. Systematic errors associated to the spectrum analysis are estimated. All these techniques were applied to study the Galactic Centre emission above 100 GeV. The nature of the source detected in 2003 and 2004 observations is still unknown and its spectrum, variability and morphology are studied. Various candidates are proposed, among them the supermassive black hole Sgr A* located at the dynamical centre of the Milky Way, the supernova remnant Sgr A Est or interactions of accelerated particles with the dense medium of this region. In this thesis, the signal was interpreted in terms of dark matter annihilation (neutralinos or Kaluza-Klein bosons) in a dense halo located at the Galactic Centre. This analysis showed that, in the framework of these models, dark matter annihilation alone can not explain the H.E.S.S. signal. The main component would thus come from astrophysical sources. (author)

  18. Estudio de las interacciones OHÏ€ por espectroscopia infrarroja y calorimetría de solución

    Directory of Open Access Journals (Sweden)

    Nelly Rodríguez C.

    2009-06-01

    Full Text Available Se estudiaron las interacciones moleculares del tipo OH . . . Ï€ existentes entre algunos fenoles y el benceno, usando como solvente tetracloruro de carbono a 25°C, mediante calorimetría de solución y espectroscopia infrarroja. Las entalpias de formación de los complejos, calculadas por métodos calorimétricos en base a las ecuaciones de Bolles-Drago y de Lamberts-Zeegers-Huyskens y de acuerdo a los datos de constantes de equilibrio obtenidos por el método infrarrojo, resultaron ser del orden de —1 a —2 kcal/mol, valores que las sitúan entre las uniones más débiles.

  19. Adsorption of methylene blue on raw and MTZ/imogolite hybrid surfaces: Effect of concentration and calorimetric investigation

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Denis L., E-mail: dlguerra@pq.cnpq.br [Universidade Federal de Mato Grosso, DRM, UFMT, Mato Grosso 78060 900 (Brazil); Batista, Adriano C. [Universidade Estadual do Norte Fluminense, UENF, Rio de Janeiro 28013 02 (Brazil); Viana, Rubia R. [Universidade Federal de Mato Grosso, DRM, UFMT, Mato Grosso 78060 900 (Brazil); Airoldi, Claudio [Chemistry Institute, State University of Campinas, PO Box 6154, 13084-971 Campinas, Sao Paulo (Brazil)

    2010-11-15

    The synthetic imogolite sample was used for organofunctionalization process with 2-mercaptothiazoline (MTZ). The compound 2-mercaptothiazoline was anchored onto imogolite surface by heterogeneous route. Due to the increment of basic centers attached to the pendant chains the dye adsorption capability of the final chelating material, was found to be higher than is precursor. The ability of these materials to remove methylene blue from aqueous solution was followed by a series of adsorption isotherms at room temperature and pH 4.0. The maximum number of moles adsorbed was determined to be 40.32 x 10{sup -2} and 65.13 x 10{sup -2} mmol g{sup -1} for IMO and IMO{sub MTZ}, respectively. The energetic effects caused by dye cations adsorption were determined through calorimetric titrations. Thermodynamics indicated the existence of favorable conditions for such methylene blue-nitrogen and sulfur interactions.

  20. Thermodynamic study of rhodamine 123-calf thymus DNA interaction: determination of calorimetric enthalpy by optical melting study.

    Science.gov (United States)

    Masum, Abdulla Al; Chakraborty, Maharudra; Pandya, Prateek; Halder, Umesh Chandra; Islam, Md Maidul; Mukhopadhyay, Subrata

    2014-11-20

    In this paper, the interaction of rhodamine123 (R123) with calf thymus DNA has been studied using molecular modeling and other biophysical methods like UV-vis spectroscopy, fluoremetry, optical melting, isothermal titration calorimetry, and circular dichroic studies. Results showed that the binding energy is about -6 to -8 kcal/mol, and the binding process is favored by both negative enthalpy change and positive entropy change. A new method to determine different thermodynamic properties like calorimetric enthalpy and heat capacity change has been introduced in this paper. The obtained data has been crossed-checked by other methods. After dissecting the free-energy contribution, it was observed that the binding was favored by both negative hydrophobic free energy and negative molecular free energy which compensated for the positive free energies due to the conformational change loss of rotational and transitional freedom of the DNA helix.

  1. A micromachined calorimetric gas sensor: an application of electrodeposited nanostructured palladium for the detection of combustible gases.

    Science.gov (United States)

    Bartlett, Philip N; Guerin, Samuel

    2003-01-01

    Palladium films with regular nanoarchitectures were electrochemically deposited from the hexagonal (H1) lyotropic liquid crystalline phase of the nonionic surfactant octaethyleneglycol monohexadecyl ether (C16EO8) onto micromachined silicon hotplate structures. The H1-e Pd films were shown to have high surface areas (approximately 28 m2 g(-1)) and to act as effective and stable catalysts for the detection of methane in air on heating to 500 degrees C. The response of the H1-e Pd-coated planar pellistors was found to be linearly proportional to the concentration of methane between 0 and 2.5% in air with a detection limit below 0.125%. Our results show that the electrochemical deposition of nanostructured metal films offers a promising approach to the fabrication of micromachined calorimetric gas sensors for combustible gases.

  2. Determinación de un polimorfo de la cimetidina mediante la calorimetría diferencial de barrido

    Directory of Open Access Journals (Sweden)

    Luis Martínez Álvarez

    1997-12-01

    Full Text Available Se estableció la diferencia entre 2 sustancias de masa molecular similar -la cimetidina A y la B-, pero de estructuras internas distintas, mediante el empleo de la técnica de calorimetría diferencial de barrido donde solamente una de ellas, la cimetidina B, posee la actividad farmacológica requerida, es decir, cumple con las especificaciones de la farmacopea.The difference between two substances of similar mollecular mass but of different internal structuras -cimetidine A and B- was established by using the differential scanning calorimetry. It was proved that only one of them, cimetidine B, has the required pharmacological activity, which means that it fulfills the pharmacopoeia specifications.

  3. An assessment by calorimetric calculations of the potential thermal benefit of warming and humidification of insufflated carbon dioxide.

    Science.gov (United States)

    Roth, Jonathan V; Sea, Stephanie

    2014-06-01

    Heat transfer from a patient to warm and humidify insufflated carbon dioxide (CO2) during laparoscopic surgery may contribute to perioperative hypothermia. The magnitude of this effect was calculated using calorimetric calculations. Warming to 37°C and humidifying to 100%, each 100 L of insufflated CO2 would prevent a heat transfer of 3220 calories, which would result in a decrease of temperature by 0.06°C in a 70 kg patient after total body distribution of heat. We conclude that the thermal benefit of warming and humidifying insufflated CO2 is minor, particularly in comparison with other effective and inexpensive perioperative technologies, some of which are not always used out could easily be used. The decision to use heating and humidification of insufflated CO2 should be based on its other risks, benefits, and costs.

  4. Qualification procedure of the electromagnetic calorimeter of the ATLAS detector; Conception et mise au point de la procedure de qualification du calorimetre electromagnetique a argon liquide du detecteur ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Massol, N

    2000-04-19

    LHC is the next collider based at CERN in Europe. The purpose of this machine is the Higgs boson and SUSY particles search. The detectors must have an excellent electromagnetic calorimetry to measure electron and photon energy. To maximize the signal to noise ratio for a low mass Higgs, it is fundamental to obtain a constant term as small as possible. LAPP is participating in the construction of the liquid argon electromagnetic calorimeter of the ATLAS collaboration. This technology is well adapted to the LHC experimental conditions. A systematic procedure to qualify the modules of this detector is an essential step to guarantee a 0,7% constant term, which is the collaboration objective. The procedure detailed in this thesis consists of quality monitoring during mechanical assembly and of a set of electrical tests such as electrical continuity, cell and cross-talk capacitance measurement, and high-voltage behaviour. For the whole test, it has been necessary to develop dedicated electronic cards, to develop measurement methods, and the whole operation software. Making the procedure automatic will guarantee the quality of each module during assembly, cabling, and test in liquid argon. (author)

  5. Calibration of triaxial fluxgate gradiometer

    International Nuclear Information System (INIS)

    Vcelak, Jan

    2006-01-01

    The description of simple and fast calibration procedures used for double-probe triaxial fluxgate gradiometer is provided in this paper. The calibration procedure consists of three basic steps. In the first step both probes are calibrated independently in order to reach constant total field reading in every position. Both probes are numerically aligned in the second step in order that the gradient reading is zero in homogenous magnetic field. The third step consists of periodic drift calibration during measurement. The results and detailed description of each calibration step are presented and discussed in the paper. The gradiometer is finally verified during the detection of the metal object in the measuring grid

  6. Primary calibration in acoustics metrology

    International Nuclear Information System (INIS)

    Milhomem, T A Bacelar; Soares, Z M Defilippo

    2015-01-01

    SI unit in acoustics is realized by the reciprocity calibrations of laboratory standard microphones in pressure field, free field and diffuse field. Calibrations in pressure field and in free field are already consolidated and the Inmetro already done them. Calibration in diffuse field is not yet consolidated, however, some national metrology institutes, including Inmetro, are conducting researches on this subject. This paper presents the reciprocity calibration, the results of Inmetro in recent key comparisons and the research that is being developed for the implementation of reciprocity calibration in diffuse field

  7. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Joseph Rovani; Mark Sanderson

    2008-02-29

    Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The

  8. Importance of 241 Am Determination in the Characterization of PuO2 Standards for Calorimetric Assay.

    Energy Technology Data Exchange (ETDEWEB)

    Sampson, Thomas E.

    2005-01-01

    Plutonium dioxide (PuO{sub 2}) standards are often used both as heat standards and isotopic standards for calorimetric assay. Calorimetric assay is the combination of the power in watts measured in a calorimeter with the effective specific power (P{sub eff}) in watts/g Pu, determined either by nondestructive gamma-ray assay or by destructive mass spectrometry, to yield the total elemental plutonium mass in the sample. To use a PuO{sub 2} sample as a heat standard for calorimetry, one must determine both the plutonium mass and P{sub eff} with very small uncertainties and then calculate the sample watts from the known plutonium mass, specific powers, and isotopic composition. Well-characterized PuO{sub 2} standards have plutonium mass values determined by analytical chemistry with a precision and accuracy on the order of 0.1%-0.2% relative to the total mass of the sample. Mass spectrometry, typically used to determine the isotopic fractions of plutonium standards, is very accurate and precise for the major isotopes but is somewhat less precise for low-abundance isotopes. The characterization of the {sup 241}Am/Pu ratio in the standard is also of great importance because {sup 241}Am can contribute significantly to P{sub eff} and to the heat output of the standard. The determination of the {sup 241}Am/Pu ratio in a plutonium-bearing sample is a process that is less standardized than mass spectrometry. There are no certified reference materials (CRMs) traceable to the national measurement system for {sup 241}Am in plutonium, and routine analytical {sup 241}Am/Pu ratio measurements often exhibit uncertainties of several percent relative to the total plutonium or greater.

  9. Thermodynamic properties of liquid silver-gallium alloys determined from e.m.f. and calorimetric measurements

    International Nuclear Information System (INIS)

    Jendrzejczyk-Handzlik, Dominika; Fitzner, Krzysztof

    2011-01-01

    The thermodynamic properties of the liquid Ag-Ga alloys were determined using e.m.f. and calorimetric methods. In the e.m.f. method, solid oxide galvanic cells were used with zirconia electrolyte. The cells of the type W,Ag x Ga (1-x) ,Ga 2 O 3 //ZrO 2 +(Y 2 O 3 )//FeO,Fe,W were used in the temperature range from 1098 K to 1273 K, and in the range of mole fraction from x Ga = 0.1 to x Ga = 1.0. At first, the Gibbs free energy of formation of pure solid gallium oxide, Ga 2 O 3 , from pure elements was derived. Using values of the measured e.m.f. for the cell with x Ga = 1.0, the following temperature dependence was obtained: Δ f G m,Ga 2 O 3 0 (±4kJ·mol -1 J)=-1061.7235+0.2899T/K. Next, the activity of the gallium was derived as a function of the alloy composition from the values of the measured e.m.f. Activities of silver were calculated using the Gibbs-Duhem equation. The drop calorimetric measurements were carried out at two temperatures, viz. 923 K and 1123 K, using a Setaram MHTC calorimeter. Integral enthalpies of mixing of liquid binary alloys were determined at those temperatures. Finally, thermodynamic properties of the liquid alloys were described with the Redlich-Kister equation using ThermoCalc software.

  10. Le vide univers du tout et du rien

    CERN Document Server

    Diner, Simon

    1997-01-01

    Pourquoi l'Univers plutôt que le vide ? Le temps et l'espace existent-ils en l'absence de l'Univers ? Que reste-t-il quand tout est enlevé ? Pourquoi quelque chose plutôt que rien ? Depuis des siècles, ces interrogations mobilisent philosophes et physiciens. Mais aujourd'hui, le vide n'est pas le rien. Il serait même l'acteur central de l'histoire de la matière et de l'Univers, le partenaire privilégié de la physique. Vide et matière ne sont plus deux manifestations séparées de la nature, mais deux aspects d'une même réalité. Le vide est l'état de base dont la matière émerge, sans couper son cordon ombilical Le vide comme Univers du rien cède la place au vide comme Univers du tout. Que le vide puisse être conçu par les physiciens comme réservoir potentiel d'univers, voici qui ne devrait laisser personne indifférent. Ce livre ouvre un débat et nous convie à une réflexion surprenante.

  11. Image du savoir, image du pouvoir dans le Lapidaire

    Directory of Open Access Journals (Sweden)

    Marta LACOMBA

    2007-01-01

    Full Text Available À travers le prologue et les enluminures de présentation, le Lapidaire d’Alphonse X oriente l’interprétation de l’œuvre. Ces paratextes mettent en avant le rôle capital du savoir, représenté par la métaphore du trésor caché, qui a ici une valeur topique. Ils mettent également en exergue le rôle que s’attribue le roi dans la transmission de ce savoir, et placent cette nouvelle attribution royale au cœur de son projet politique.A través del prólogo y las miniaturas de presentación, el Lapidario de Alfonso X orienta la interpretación de la obra. Estos paratextos subrayan el papel capital del saber, representado por la metáfora del tesoro escondido, que tiene aquí un valor tópico. Ponen asimismo de manifiesto el papel que se atribuye el monarca en la transmisión de ese saber y colocan esta nueva atribución real en el centro de su proyecto político.

  12. Main: 1DU5 [RPSD[Archive

    Lifescience Database Archive (English)

    Full Text Available 1DU5 トウモロコシ Corn Zea mays L. Zeamatin Precursor. Name=Zlp; Zea Mays Molecule: Zeamatin; Chai...eta Sandwich SWS:ZEAM_MAIZE,P33679|EMBL; U06831; AAA92882.1; -.|PIR; T02075; T02075.|PDB; 1DU5; X-ray; A/B=22-227.|Mai

  13. les cahiers du cread: About this journal

    African Journals Online (AJOL)

    les cahiers du cread: About this journal. Journal Home > les cahiers du cread: About this journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. People. » Contact. Policies.

  14. Les figures multiples du maire.

    Directory of Open Access Journals (Sweden)

    Olivier Lebraud

    2004-06-01

    Full Text Available Alors même que l’ensemble du personnel gouvernemental et parlementaire est sujet à une relative désaffection de la part des citoyens, les maires français jouissent, on le sait, d’une popularité qui fait d’eux les figures centrales de la scène politique. Au-delà de la décentralisation, qui a souvent renforcé leur image de décideurs, ils ont su tirer parti de la dimension identitaire qui caractérise l’échelon communal pour devenir les acteurs indispensables de la vie locale. ...

  15. Vers une anthropologie du Confucianisme

    OpenAIRE

    Rieu , Alain-Marc

    2010-01-01

    Research in Anthropology developed in France by Jean-Pierre Vernant, Marcel Détienne and Philippe Descola opens the possibility to reframe the debate and research on the function of Confucianism in Chinese culture, history and society. This paper shows how Confucianism can be studied as a "mythology"; La fonction du Confucianisme dans l'histoire de la société et de la culture chinoise, les débats et les reconstructions dont il est l'objet et l'enjeu, ouvre la possibilité de l'étudier d'un poi...

  16. Session du Conseil du CERN : le ministre britannique, Robert Jackson, souligne l'intérêt de on pays pour l'avenir du CERN : décisions du Conseil pour la mise en oeuvre des recommandations du Comité d'évaluation du CERN: départ anticipé pour 200 membres au moins du personnel - mise à jour de la méthode de calcule pour les contributions des Etats Membres au budget

    CERN Multimedia

    CERN Press Office. Geneva

    1988-01-01

    Session du Conseil du CERN : le ministre britannique, Robert Jackson, souligne l'intérêt de on pays pour l'avenir du CERN : décisions du Conseil pour la mise en oeuvre des recommandations du Comité d'évaluation du CERN: départ anticipé pour 200 membres au moins du personnel - mise à jour de la méthode de calcule pour les contributions des Etats Membres au budget

  17. The CHEOPS calibration bench

    Science.gov (United States)

    Wildi, F.; Chazelas, B.; Deline, A.; Sarajlic, M.; Sordet, M.

    2017-09-01

    CHEOPS is an ESA Class S Mission aiming at the characterization of exoplanets through the precise measurement of their radius, using the transit method [1]. To achieve this goal, the payload is designed to be a high precision "absolute" photometer, looking at one star at a time. It will be able to cover la large fraction of the sky by repointing. Its launch is expected at the end of 2017 [2, this conference]. CHEOPS' main science is the measure of the transit of exoplanets of radius ranging from 1 to 6 Earth radii orbiting bright stars. The required photometric stability to reach this goal is of 20 ppm in 6 hours for a 9th magnitude star. The CHEOPS' only instrument is a Ritchey-Chretien style telescope with 300 mm effective aperture diameter, which provides a defocussed image of the target star on a single frame-transfer backside illuminated CCD detector cooled to -40°C and stabilized within 10 mK [2]. CHEOPS being in a LEO, it is equipped with a high performance baffle. The spacecraft platform provides a pointing stability of < 2 arcsec rms. This relatively modest pointing performance makes high quality flat-fielding necessary In the rest of this article we will refer to the only CHEOPS instrument simply as "CHEOP" Its behavior will be calibrated thoroughly on the ground and only a small subset of the calibrations can be redone in flight. The main focuses of the calibrations are the photonic gain stability and sensibility to the environment variations and the Flat field that has to be known at a precision better than 0.1%.

  18. CALIBRATED HYDRODYNAMIC MODEL

    Directory of Open Access Journals (Sweden)

    Sezar Gülbaz

    2015-01-01

    Full Text Available The land development and increase in urbanization in a watershed affect water quantityand water quality. On one hand, urbanization provokes the adjustment of geomorphicstructure of the streams, ultimately raises peak flow rate which causes flood; on theother hand, it diminishes water quality which results in an increase in Total SuspendedSolid (TSS. Consequently, sediment accumulation in downstream of urban areas isobserved which is not preferred for longer life of dams. In order to overcome thesediment accumulation problem in dams, the amount of TSS in streams and inwatersheds should be taken under control. Low Impact Development (LID is a BestManagement Practice (BMP which may be used for this purpose. It is a land planningand engineering design method which is applied in managing storm water runoff inorder to reduce flooding as well as simultaneously improve water quality. LID includestechniques to predict suspended solid loads in surface runoff generated over imperviousurban surfaces. In this study, the impact of LID-BMPs on surface runoff and TSS isinvestigated by employing a calibrated hydrodynamic model for Sazlidere Watershedwhich is located in Istanbul, Turkey. For this purpose, a calibrated hydrodynamicmodel was developed by using Environmental Protection Agency Storm WaterManagement Model (EPA SWMM. For model calibration and validation, we set up arain gauge and a flow meter into the field and obtain rainfall and flow rate data. Andthen, we select several LID types such as retention basins, vegetative swales andpermeable pavement and we obtain their influence on peak flow rate and pollutantbuildup and washoff for TSS. Consequently, we observe the possible effects ofLID on surface runoff and TSS in Sazlidere Watershed.

  19. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  20. Self-calibrating interferometer

    International Nuclear Information System (INIS)

    Nussmeier, T.A.

    1982-01-01

    A self-calibrating interferometer is disclosed which forms therein a pair of Michelson interferometers with one beam length of each Michelson interferometer being controlled by a common phase shifter. The transfer function measured from the phase shifter to either of a pair of detectors is sinusoidal with a full cycle for each half wavelength of phase shifter travel. The phase difference between these two sinusoidal detector outputs represents the optical phase difference between a path of known distance and a path of unknown distance

  1. Acquisition of rheological and calorimetric properties of borosilicate glass to determine the free energy of formation

    International Nuclear Information System (INIS)

    Linard, Y.; Advocat, Th.

    2000-01-01

    standard glass chemical potentials based on the measured calorimetric and rheological properties. (authors)

  2. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  3. Piezoelectric trace vapor calibrator

    International Nuclear Information System (INIS)

    Verkouteren, R. Michael; Gillen, Greg; Taylor, David W.

    2006-01-01

    The design and performance of a vapor generator for calibration and testing of trace chemical sensors are described. The device utilizes piezoelectric ink-jet nozzles to dispense and vaporize precisely known amounts of analyte solutions as monodisperse droplets onto a hot ceramic surface, where the generated vapors are mixed with air before exiting the device. Injected droplets are monitored by microscope with strobed illumination, and the reproducibility of droplet volumes is optimized by adjustment of piezoelectric wave form parameters. Complete vaporization of the droplets occurs only across a 10 deg. C window within the transition boiling regime of the solvent, and the minimum and maximum rates of trace analyte that may be injected and evaporated are determined by thermodynamic principles and empirical observations of droplet formation and stability. By varying solution concentrations, droplet injection rates, air flow, and the number of active nozzles, the system is designed to deliver--on demand--continuous vapor concentrations across more than six orders of magnitude (nominally 290 fg/l to 1.05 μg/l). Vapor pulses containing femtogram to microgram quantities of analyte may also be generated. Calibrated ranges of three explosive vapors at ng/l levels were generated by the device and directly measured by ion mobility spectrometry (IMS). These data demonstrate expected linear trends within the limited working range of the IMS detector and also exhibit subtle nonlinear behavior from the IMS measurement process

  4. A Simple Accelerometer Calibrator

    International Nuclear Information System (INIS)

    Salam, R A; Islamy, M R F; Khairurrijal; Munir, M M; Latief, H; Irsyam, M

    2016-01-01

    High possibility of earthquake could lead to the high number of victims caused by it. It also can cause other hazards such as tsunami, landslide, etc. In that case it requires a system that can examine the earthquake occurrence. Some possible system to detect earthquake is by creating a vibration sensor system using accelerometer. However, the output of the system is usually put in the form of acceleration data. Therefore, a calibrator system for accelerometer to sense the vibration is needed. In this study, a simple accelerometer calibrator has been developed using 12 V DC motor, optocoupler, Liquid Crystal Display (LCD) and AVR 328 microcontroller as controller system. The system uses the Pulse Wave Modulation (PWM) form microcontroller to control the motor rotational speed as response to vibration frequency. The frequency of vibration was read by optocoupler and then those data was used as feedback to the system. The results show that the systems could control the rotational speed and the vibration frequencies in accordance with the defined PWM. (paper)

  5. Bases en technique du vide

    CERN Document Server

    Rommel, Guy

    2017-01-01

    Cette seconde édition, 20 ans après la première, devrait continuer à aider les techniciens pour la réalisation de leur système de vide. La technologie du vide est utilisée, à présent, dans de nombreux domaines très différents les uns des autres et avec des matériels très fiables. Or, elle est souvent bien peu étudiée, de plus, c'est une discipline où le savoir-faire prend tout son sens. Malheureusement la transmission par des ingénieurs et techniciens expérimentés ne se fait plus ou trop rapidement. La technologie du vide fait appel à la physique, à la chimie, à la mécanique, à la métallurgie, au dessin industriel, à l'électronique, à la thermique, etc. Cette discipline demande donc de maîtriser des techniques de domaines très divers, et ce n'est pas chose facile. Chaque installation est en soi un cas particulier avec ses besoins, sa façon de traiter les matériaux et celle d'utiliser les matériels. Les systèmes de vide sont parfois copiés d'un laboratoire à un autre et le...

  6. Culture du bambou : diversification des moyens de subsistance des ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Culture du bambou : diversification des moyens de subsistance des petits producteurs de tabac du sud de la province de Nyanza, au Kenya - phase II. Au cours de la première phase du projet (projet no 103765), les chercheurs ont effectué une analyse de marché pour le bambou et les produits du bambou, comparé les ...

  7. On chromatic and geometrical calibration

    DEFF Research Database (Denmark)

    Folm-Hansen, Jørgen

    1999-01-01

    The main subject of the present thesis is different methods for the geometrical and chromatic calibration of cameras in various environments. For the monochromatic issues of the calibration we present the acquisition of monochrome images, the classic monochrome aberrations and the various sources...... the correct interpolation method is described. For the chromatic issues of calibration we present the acquisition of colour and multi-spectral images, the chromatic aberrations and the various lens/camera based non-uniformities of the illumination of the image plane. It is described how the monochromatic...... to design calibration targets for both geometrical and chromatic calibration are described. We present some possible systematical errors on the detection of the objects in the calibration targets, if viewed in a non orthogonal angle, if the intensities are uneven or if the image blurring is uneven. Finally...

  8. Development of portable flow calibrator

    International Nuclear Information System (INIS)

    Akiyama, Kiyomitsu; Iijima, Nobuo

    1995-01-01

    In the nuclear facilities, air sniffer system is often utilized to evaluate atmospheric concentration of radioactivity in the working environment. The system collects airborne dust on the filter during some sampling period. In this method, total air flow during the sampling period is an important parameter to evaluate the radioactivity concentration correctly. Therefore, calibration for the flow meter of air sniffer system must be done periodically according to Japan Industry Standards (JIS). As we have had to available device to calibrate the flow meter in the working area, we had to remove the flow meters from the installed place and carry them to another place where calibration can be made. This work required a great deal of labor. Now we have developed a portable flow calibrator for air sniffer system which enables us to make in-site calibration of the flow meter in the working area more easily. This report describes the outline of portable flow calibrator and it's experimental results. (author)

  9. A method for calorimetric analysis in variable conditions heating; Methode d'analyse calorimetrique en regime variable

    Energy Technology Data Exchange (ETDEWEB)

    Berthier, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    By the analysis of the thermal transition conditions given by the quenching of a sample in a furnace maintained at a high temperature, it is possible to study the thermal diffusivity of some materials and those of solid state structure transformation on a qualitative as well as a quantitative standpoint. For instance the transformation energy of {alpha}-quartz into {beta}-quartz and the Wigner energy stored within neutron-irradiated beryllium oxide have been measured. (author) [French] L'analyse du regime thermique transitoire, obtenu par la trempe d'un echantillon dans l'enceinte d'un four maintenu a tres haute temperature, peut permettre l'etude de la diffusivite thermique de certains materiaux et celle des transformations structurales en phase solide, tant du point de vue qualitatif que du point de vue quantitatif (mesure de l'energie de transformation du quartz {alpha} en quartz {beta} et determination de l'energie Wigner emmagasinee par l'oxyde de beryllium irradie aux neutrons). (auteur)

  10. COMMUNICATION DU CREDIT AGRICOLE - French version only

    CERN Multimedia

    2003-01-01

    La Direction du Crédit Agricole informe son aimable clientèle du CERN des jours et heures d'ouverture de l'agence du site de Prévessin à compter du mardi 14 janvier 2003 : 1. Horaires pour les opérations bancaires courantes 7 jours sur 7 et 24h/24 avec l'espace libre service bancaire. 2. Horaires conseil du mardi au vendredi - Mardi, de 9h. à 12h. et de 14h.15 à 16h.30. - Mercredi, jeudi et vendredi, de 9h. à 12h. et de 13h.30 à 16h.30. Deux collaboratrices au lieu d'une seront désormais présentes toute la journée du mardi au vendredi pour vous accueillir, vous informer et vous conseiller en crédits et placements (réception conseil sur rendez-vous). Autre nouveauté : les mêmes conseillers seront aussi à votre disposition le samedi, sur notre agence de Gex, de 8h.15 à 13h.05, notamment pour les études de financements habitat. La Direction et toute l'équipe de l'agence du Crédit Agricole vous souhaitent une excellent année 2003.

  11. Nouvelles du Centre Aéré de l’Association du Personnel du CERN

    CERN Multimedia

    Jardin d'enfants

    2015-01-01

    Cet été 2015, durant quatre semaines d’été, le Centre Aéré a accueilli plus de 40 enfants âgés de 4 à 6 ans. Devant le succès rencontré, et à la demande des parents, il a été décidé d’en doubler la capacité maximale. A l'été 2016, du 4 au 29 juillet, la structure pourra accueillir les enfants de 4 ans révolus et de moins de 7 ans (nés après le 31/07/2009 mais avant  01/07/2012). Les inscriptions se feront à la semaine durant le mois d'Avril 2016. Les programmes sont en cours d'élaboration cependant nous pouvons déjà vous communiquer le thème conducteur du centre qui sera : à la découverte d'un continent différent chaque ...

  12. Quality Management and Calibration

    Science.gov (United States)

    Merkus, Henk G.

    Good specification of a product’s performance requires adequate characterization of relevant properties. Particulate products are usually characterized by some PSD, shape or porosity parameter(s). For proper characterization, adequate sampling, dispersion, and measurement procedures should be available or developed and skilful personnel should use appropriate, well-calibrated/qualified equipment. The characterization should be executed, in agreement with customers, in a wellorganized laboratory. All related aspects should be laid down in a quality handbook. The laboratory should provide proof for its capability to perform the characterization of stated products and/or reference materials within stated confidence limits. This can be done either by internal validation and audits or by external GLP accreditation.

  13. SURF Model Calibration Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-10

    SURF and SURFplus are high explosive reactive burn models for shock initiation and propagation of detonation waves. They are engineering models motivated by the ignition & growth concept of high spots and for SURFplus a second slow reaction for the energy release from carbon clustering. A key feature of the SURF model is that there is a partial decoupling between model parameters and detonation properties. This enables reduced sets of independent parameters to be calibrated sequentially for the initiation and propagation regimes. Here we focus on a methodology for tting the initiation parameters to Pop plot data based on 1-D simulations to compute a numerical Pop plot. In addition, the strategy for tting the remaining parameters for the propagation regime and failure diameter is discussed.

  14. Calibration of Nanopositioning Stages

    Directory of Open Access Journals (Sweden)

    Ning Tan

    2015-12-01

    Full Text Available Accuracy is one of the most important criteria for the performance evaluation of micro- and nanorobots or systems. Nanopositioning stages are used to achieve the high positioning resolution and accuracy for a wide and growing scope of applications. However, their positioning accuracy and repeatability are not well known and difficult to guarantee, which induces many drawbacks for many applications. For example, in the mechanical characterisation of biological samples, it is difficult to perform several cycles in a repeatable way so as not to induce negative influences on the study. It also prevents one from controlling accurately a tool with respect to a sample without adding additional sensors for closed loop control. This paper aims at quantifying the positioning repeatability and accuracy based on the ISO 9283:1998 standard, and analyzing factors influencing positioning accuracy onto a case study of 1-DoF (Degree-of-Freedom nanopositioning stage. The influence of thermal drift is notably quantified. Performances improvement of the nanopositioning stage are then investigated through robot calibration (i.e., open-loop approach. Two models (static and adaptive models are proposed to compensate for both geometric errors and thermal drift. Validation experiments are conducted over a long period (several days showing that the accuracy of the stage is improved from typical micrometer range to 400 nm using the static model and even down to 100 nm using the adaptive model. In addition, we extend the 1-DoF calibration to multi-DoF with a case study of a 2-DoF nanopositioning robot. Results demonstrate that the model efficiently improved the 2D accuracy from 1400 nm to 200 nm.

  15. Radiological Calibration and Standards Facility

    Data.gov (United States)

    Federal Laboratory Consortium — PNNL maintains a state-of-the-art Radiological Calibration and Standards Laboratory on the Hanford Site at Richland, Washington. Laboratory staff provide expertise...

  16. Portable compact multifunction IR calibrator

    International Nuclear Information System (INIS)

    Wyatt, C.L.; Jacobsen, L.; Steed, A.

    1988-01-01

    A compact portable multifunction calibrator designed for future sensor systems is described which enables a linearity calibration for all detectors simultaneously using a near small-area source, a high-resolution mapping of the focal plane with 10 microrad setability and with a blur of less than 100 microrad, system spectral response calibration (radiometer) using a Michelson interferometer source, relative spectral response (spectrometer) using high-temperature external commercial blackbody simulators, and an absolute calibration using an internal low-temperature extended-area source. 5 references

  17. BXS Re-calibration

    International Nuclear Information System (INIS)

    Welch, J.

    2010-01-01

    Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel

  18. Coordonnateur du bureau d'assistance | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Résumé des fonctions. En tant que membre de l'équipe du Bureau d'assistance au sein de la Section du service à la clientèle (SSC), le coordonnateur du Bureau d'assistance offre au personnel du Centre et aux autres utilisateurs reconnus des installations TI du Centre un soutien de première ligne en matière d'utilisation ...

  19. La population du Moyen-Orient et de l'Afrique du Nord contribue ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    29 avr. 2016 ... Le degré d'apport au contenu varie grandement d'une population à l'autre. Si les habitants du Moyen-Orient et de l'Afrique du Nord (région MENA) utilisent Wikipédia, ils y contribuent cependant moins que les populations d'autres régions du monde. Le contenu au sujet de la région MENA est, le plus ...

  20. L'action du CRDI — le développement du secteur privé

    International Development Research Centre (IDRC) Digital Library (Canada)

    Cathy Egan

    Le CRDI est du nombre. Il reconnaît depuis longtemps la valeur de l'industrie, des échanges et du commerce comme moteurs de la croissance économique. Grâce au soutien concret qu'il a accordé au développement du secteur privé, le CRDI a appris que deux types d'aide peuvent porter fruit : améliorer le con- texte dans ...

  1. Critical temperatures and a critical chain length in saturated diacylphosphatidylcholines: calorimetric, ultrasonic and Monte Carlo simulation study of chain-melting/ordering in aqueous lipid dispersions.

    Science.gov (United States)

    Kharakoz, Dmitry P; Panchelyuga, Maria S; Tiktopulo, Elizaveta I; Shlyapnikova, Elena A

    2007-12-01

    Chain-ordering/melting transition in a series of saturated diacylphosphatidylcholines (PCs) in aqueous dispersions have been studied experimentally (calorimetric and ultrasonic techniques) and theoretically (an Ising-like lattice model). The shape of the calorimetric curves was compared with the theoretical data and interpreted in terms of the lateral interactions and critical temperatures determined for each lipid studied. A critical chain length has been found (between 16 and 17 C-atoms per chain) which subdivides PCs into two classes with different phase behavior. In shorter lipids, the transition takes place above their critical temperatures meaning that this is an intrinsically continuous transition. In longer lipids, the transition occurs below the critical temperatures of the lipids, meaning that the transition is intrinsically discontinuous (first-order). This conclusion was supported independently by the ultrasonic relaxation sensitive to density fluctuations. Interestingly, it is this length that is the most abundant among the saturated chains in biological membranes.

  2. Exposure-rate calibration using large-area calibration pads

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-09-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. A set of large-area, radioelement-enriched concrete pads was constructed by the DOE in 1978 at the Walker Field Airport in Grand Junction for use as calibration standards for airborne gamma-ray spectrometer systems. The use of these pads was investigated by the TMC as potential calibration standards for portable scintillometers employed in measuring gamma-ray exposure rates at Uranium Mill Tailings Remedial Action (UMTRA) project sites. Data acquired on the pads using a pressurized ionization chamber (PIC) and three scintillometers are presented as an illustration of an instrumental calibration. Conclusions and recommended calibration procedures are discussed, based on the results of these data

  3. Sulphite metabolism; Metabolisme du sulfite

    Energy Technology Data Exchange (ETDEWEB)

    Fromageot, P; Chapeville, F [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Although the formation of sulphite by micro-organisms was observed as early as 1914 by Neuberg, it was only in 1932 that Nightingale showed it to be present inside cells, in the case of tomato leaf stalks, its formation being due to the reaction: SO{sub 3}H{sup -} + (S{sub 2}O{sub 3}){sub 2}{sup --} {yields} S{sub 2}O{sub 3}{sup --} + O{sub 3}S{sub 2}O{sub 3}{sup --}. The presence of the thiosulphate formed was shown by the high refractive index of its barium salt. Today we have a certain amount of data concerning the formation and use of sulphite in the living cell, even through the knowledge is still incomplete. In this article we will describe and discuss the facts which are known, with particular reference to the oxidation of sulphite. (author) [French] Si la formation de sulfite par des micro-organismes a ete observee des 1914 par Neuberg, sa presence a l'interieur des cellules a ete demontree pour la premiere fois par Nightingale en 1932, dans des tiges et des feuilles de tomates, par la reaction: SO{sub 3}H{sup -} + (S{sub 2}O{sub 3}){sub 2}{sup --} {yields} S{sub 2}O{sub 3}{sup --} + O{sub 3}S{sub 2}O{sub 3}{sup --}. Le thiosulfate forme etait mis en evidence par l'indice de refraction eleve de son sel de baryum. Aujourd'hui on possede un certain nombre de donnees, cependant encore tres incompletes, sur la formation du sulfite et son utilisation par la cellule vivante. Dans cet expose nous decrirons et discuterons quelques-unes de ces acquisitions, tout particulierement celles relatives a l'oxydation du sulfite. (auteur)

  4. LANL MTI calibration team experience

    Science.gov (United States)

    Bender, Steven C.; Atkins, William H.; Clodius, William B.; Little, Cynthia K.; Christensen, R. Wynn

    2004-01-01

    The Multispectral Thermal Imager (MTI) was designed as an imaging radiometer with absolute calibration requirements established by Department of Energy (DOE) mission goals. Particular emphasis was given to water surface temperature retrieval using two mid wave and three long wave infrared spectral bands, the fundamental requirement was a surface temperature determination of 1K at the 68% confidence level. For the ten solar reflective bands a one-sigma radiometric performance goal of 3% was established. In order to address these technical challenges a calibration facility was constructed containing newly designed sources that were calibrated at NIST. Additionally, the design of the payload and its onboard calibration system supported post launch maintenance and update of the ground calibration. The on-orbit calibration philosophy also included vicarious techniques using ocean buoys, playas and other instrumented sites; these became increasingly important subsequent to an electrical failure which disabled the onboard calibration system. This paper offers various relevant lessons learned in the eight-year process of reducing to practice the calibration capability required by the scientific mission. The discussion presented will include observations pertinent to operational and procedural issues as well as hardware experiences; the validity of some of the initial assumptions will also be explored.

  5. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Kristensen, L.; Jensen, G.; Hansen, A.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statisticalsignificance of the calibration expressions...

  6. Cobalt source calibration

    International Nuclear Information System (INIS)

    Rizvi, H.M.

    1999-01-01

    The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 10 5 rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 10 5 rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 10 5 rad/h to 1.073 x 10 5 rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 10 6 to 9.27 x 10 5 . This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 10 7 rad/h. During irradiation of the Fricke dosimeter solution the Fe 2+ ions ionize to Fe 3+ . When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate

  7. Monnaie du commun et revenu social garanti

    OpenAIRE

    Baronian, Laurent; Vercellone, Carlo

    2015-01-01

    Le but de cet article est de poser les bases d’une approche de la monnaie du commun à partir d’une interrogation évincée par la théorie économique des biens communs. Notre analyse de la relation entre monnaie et théorie du commun s’articulera en trois parties. Dans la première, il s’agit d’établir une conception dynamique du commun au singulier dans laquelle la question de la monnaie et des mutations de la division du travail occupe une place centrale. Cette démarche fondée sur la triade trav...

  8. Paysans du Brésil

    Directory of Open Access Journals (Sweden)

    Dominique Temple

    2007-01-01

    Full Text Available Eric Sabourin, « Paysans du Brésil : Entre échange marchand et réciprocité » Paris, Editions Quae, 241p, 30 euros, (préface de Maxime Haubert, 2007Dans la présentation du livre, Maxime Haubert dit :«Cet ouvrage propose une analyse socio-anthropologique et agronomique des sociétés rurales et paysannes du Brésil et des transformations qu'elles ont connues ces dernières décennies, en particulier face aux interventions de l'Etat et à l'expansion du marché capitaliste (.... «Le livre pose d'abor...

  9. Daphne du Maurier' unustatud jutud / Udo Uibo

    Index Scriptorium Estoniae

    Uibo, Udo, 1956-

    2011-01-01

    Ajalehe "The Independent" teatel kavatseb kirjastus "Virago" maikuus avaldada Daphne Du Maurier lühiproosa kogumiku "Nukk" (The Doll), mille on koostanud tema loomingu suur austaja Ann Willmore ja mis sisaldab 13 unustatud ja seni avaldamata novelli

  10. Liquid Krypton Calorimeter Calibration Software

    CERN Document Server

    Hughes, Christina Lindsay

    2013-01-01

    Calibration of the liquid krypton calorimeter (LKr) of the NA62 experiment is managed by a set of standalone programs, or an online calibration driver. These programs are similar to those used by NA48, but have been updated to utilize classes and translated to C++ while maintaining a common functionality. A set of classes developed to handle communication with hardware was used to develop the three standalone programs as well as the main driver program for online calibration between bursts. The main calibration driver has been designed to respond to run control commands and receive burst data, both transmitted via DIM. In order to facilitate the process of reading in calibration parameters, a serializable class has been introduced, allowing the replacement of standard text files with XML configuration files.

  11. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  12. TIME CALIBRATED OSCILLOSCOPE SWEEP CIRCUIT

    Science.gov (United States)

    Smith, V.L.; Carstensen, H.K.

    1959-11-24

    An improved time calibrated sweep circuit is presented, which extends the range of usefulness of conventional oscilloscopes as utilized for time calibrated display applications in accordance with U. S. Patent No. 2,832,002. Principal novelty resides in the provision of a pair of separate signal paths, each of which is phase and amplitude adjustable, to connect a high-frequency calibration oscillator to the output of a sawtooth generator also connected to the respective horizontal deflection plates of an oscilloscope cathode ray tube. The amplitude and phase of the calibration oscillator signals in the two signal paths are adjusted to balance out feedthrough currents capacitively coupled at high frequencies of the calibration oscillator from each horizontal deflection plate to the vertical plates of the cathode ray tube.

  13. Aux frontières du politique et du religieux

    Directory of Open Access Journals (Sweden)

    Frédéric Sylvanise

    2006-05-01

    Full Text Available The Autobiography of Miss Jane Pittman met en scène de manière spectaculaire deux figures de leadership noir-américain au XIXe siècle (Ned et au XXe siècle (Jimmy. Ned, fils adoptif de Jane Pittman, se rebaptise Professor Douglass en hommage au leader abolitionniste Frederick Douglass. S’il est fondamentalement laïc (il est instituteur, le texte lui confère néanmoins une dimension religieuse, notamment dans le chapitre intitulé « The Sermon at the River » , qui renvoie à la fois à Moïse (le fleuve et à Jésus (le sermon sur la montagne. Abattu par un tueur à gages, Ned est un martyr dont l’histoire était déjà écrite. Le personnage de Jimmy, attendu par toute une communauté comme le messie (alors que lui aussi est un laïc et un homme qui perd la foi, s’inscrit dans la même histoire. Lettré, éloquent et impliqué dans le mouvement pour les droits civils, il est assassiné comme son prédécesseur. Dans les deux cas, le texte lie donc le politique et le biblique comme s’il ne faisait qu’un : être un leader politique, c’est être un preacher et un messie qui guide le peuple. Il est possible de lire l’évocation de ces deux hommes à la lumière d’une certaine actualité. Ned et Jimmy connaissent en effet un sort proche de celui de Malcolm X et de Martin Luther King, récemment assassinés au moment de l’écriture de The Autobiography of Miss Jane Pittman. C’est l’histoire de la répression du leadership noir, au travers du portrait de deux de ses avatars, qui peut donc se lire en creux ici.

  14. Complications du traitement traditionnel des fractures : aspects ...

    African Journals Online (AJOL)

    Tous les patients reçus avec des complications du traitement traditionnel des fractures ont été inclus dans ce travail. Le diagnostic des lésions était clinique et radiologique. Nous avions reçu 51 patients porteurs de complications suite à des traitements de médecine traditionnelle, soit 13,7% du total des patients hospitalisés ...

  15. Le désordre du monde

    African Journals Online (AJOL)

    sulaiman.adebowale

    Le début du XXIe siècle se caractérise par l'accumulation et la consécution ..... Unis a présidé à la naissance aux forceps de cet outil d'équilibre du monde en ... De toute évidence, l'ONU reste l'instrument qui a marqué le siècle dernier,.

  16. Calibrating the Cryogenian

    Science.gov (United States)

    MacDonald, F. A.; Schmitz, M. D.; Crowley, J. L.; Haam, E.; Huybers, P.; Cohen, P. A.; Johnston, D. T.

    2009-12-01

    The IGCP 512 sub-commission on the Neoproterozoic is currently discussing criteria for the definition of the Cryogenian period. Herein we provide new U/Pb ID-TIMS ages and carbon and oxygen isotope data from Fifteenmile and Mt. Harper Groups in the Yukon Territory that inform the basis for the placement of the basal Cryogenian “golden spike”. Our U/Pb ages are from volcanic tuffs interbedded within glaciogenic, fossiliferous, and carbonate strata. With the current lack of Neoproterozoic index fossils and the paucity of radiogenic age constraints, chemo-stratigraphic correlations are particularly important for tuning the Neoproterozoic timescale. In an effort to move beyond conventional 'wiggle matching', chemostratigraphic correlations are determined using a new statistical method1, which indicates that the resulting chemo-stratigraphic correlations are statistically significant. These results permit us to refine and integrate Neoproterozoic climate, microfossil, and geochemical proxy records both regionally and globally. The newly calibrated microfossil record points to a eukaryotic radiation roughly coincident with the Bitter Springs isotopic stage and a barren interval between the Sturtian and Marinoan glaciations. 1 Haam, E. & Huybers, P., 2009, A test for the presence of covariance between time-uncertain series of data with applications to the Dongge Cave speleothem and atmospheric radiocarbon records, Paleoceanography, in press.

  17. pH-tuneable binding of 2′-phospho-ADP-ribose to ketopantoate reductase: a structural and calorimetric study

    International Nuclear Information System (INIS)

    Ciulli, Alessio; Lobley, Carina M. C.; Tuck, Kellie L.; Smith, Alison G.; Blundell, Tom L.; Abell, Chris

    2007-01-01

    A combined crystallographic, calorimetric and mutagenic study has been used to show how changes in pH give rise to two distinct binding modes of 2′-phospho-ADP-ribose to ketopantoate reductase. The crystal structure of Escherichia coli ketopantoate reductase in complex with 2′-monophosphoadenosine 5′-diphosphoribose, a fragment of NADP + that lacks the nicotinamide ring, is reported. The ligand is bound at the enzyme active site in the opposite orientation to that observed for NADP + , with the adenine ring occupying the lipophilic nicotinamide pocket. Isothermal titration calorimetry with R31A and N98A mutants of the enzyme is used to show that the unusual ‘reversed binding mode’ observed in the crystal is triggered by changes in the protonation of binding groups at low pH. This research has important implications for fragment-based approaches to drug design, namely that the crystallization conditions and the chemical modification of ligands can have unexpected effects on the binding modes

  18. pH-tuneable binding of 2′-phospho-ADP-ribose to ketopantoate reductase: a structural and calorimetric study

    Energy Technology Data Exchange (ETDEWEB)

    Ciulli, Alessio [University Chemical Laboratory, Lensfield Road, Cambridge CB2 1EW (United Kingdom); Lobley, Carina M. C. [Department of Biochemistry, University of Cambridge, 80 Tennis Court Road, Cambridge CB2 1GA (United Kingdom); Tuck, Kellie L. [University Chemical Laboratory, Lensfield Road, Cambridge CB2 1EW (United Kingdom); Smith, Alison G. [Department of Plant Sciences, University of Cambridge, Downing Street, Cambridge CB2 3EA (United Kingdom); Blundell, Tom L. [Department of Biochemistry, University of Cambridge, 80 Tennis Court Road, Cambridge CB2 1GA (United Kingdom); Abell, Chris, E-mail: ca26@cam.ac.uk [University Chemical Laboratory, Lensfield Road, Cambridge CB2 1EW (United Kingdom)

    2007-02-01

    A combined crystallographic, calorimetric and mutagenic study has been used to show how changes in pH give rise to two distinct binding modes of 2′-phospho-ADP-ribose to ketopantoate reductase. The crystal structure of Escherichia coli ketopantoate reductase in complex with 2′-monophosphoadenosine 5′-diphosphoribose, a fragment of NADP{sup +} that lacks the nicotinamide ring, is reported. The ligand is bound at the enzyme active site in the opposite orientation to that observed for NADP{sup +}, with the adenine ring occupying the lipophilic nicotinamide pocket. Isothermal titration calorimetry with R31A and N98A mutants of the enzyme is used to show that the unusual ‘reversed binding mode’ observed in the crystal is triggered by changes in the protonation of binding groups at low pH. This research has important implications for fragment-based approaches to drug design, namely that the crystallization conditions and the chemical modification of ligands can have unexpected effects on the binding modes.

  19. Calorimetric study at different temperatures of iodine adsorption from organic solutions on outgassed 'eta' alumina and bayerite

    International Nuclear Information System (INIS)

    Della Gatta, G.; Stradella, L.; Venturello, G.

    1977-01-01

    The adsorption of iodine from solution in n-pentane at 27 0 C and in cyclohexane at 35 0 C and 50 0 C on eta-Al 2 O 3 and bayerite outgassed at R.T. has been studied with a calorimetric technique. The measurements were performed by means of a Calvet type calorimeter using a new cell conceived for the adsorption from solution. The integral molar energies of adsorption show, at low coverages, a very strong interaction of iodine with surface hydroxyl groups, possibly leading to charge-transfer complexes and reactions. A peculiar exothermic effect has been also evidenced before the monolayer completion, in correspondence with a 'step' on the adsorption isotherms. This result is interpreted in terms of cooperative adsorption implying the possible formation of surface clusters around the strongly absorbed molecules. On non-porous samples (bayerite) the adsorption temperature rise decrease the total amounts adsorbed. But on porous ones (eta-Al 2 O 3 ) the adsorption is increased. (orig./HK) [de

  20. Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions

    Science.gov (United States)

    Kilbourne, Caroline; Kraft-Bermuth, S.; Andrianov, V.; Bleile, A.; Echler, A.; Egelhof, P.; Ilieva, S.; Kilbourne, C.; McCammon, D.

    2012-01-01

    The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.

  1. Calorimetric low - temperature detectors for high resolution X-ray spectroscopy on stored highly stripped heavy ions

    International Nuclear Information System (INIS)

    Bleile, A.; Egelhof, P.; Kraft, S.; Meier, H.J.; Shrivastava, A.; Weber, M.; McCammon, D.; Stahle, C.K.

    2001-09-01

    The accurate determination of the Lamb shift in heavy hydrogen-like ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields, not accessible otherwise. For the investigation of the Lyman-α transitions in 208 Pb 81+ or 238 U 91+ with sufficient accuracy, a high resolution calorimetric detector for hard X-rays (E ≤ 100 keV) is presently being developed. The detector modules consist of arrays of silicon thermistors and of X-ray absorbers made of high-Z material to optimize the absorption efficiency. The detectors are housed in a specially designed 3 He/ 4 He dilution refrigerator with a side arm which fits to the internal target geometry of the storage ring ESR at GSI Darmstadt. The detector performance presently achieved is already close to fulfill the demands of the Lamb shift experiment. For a prototype detector pixel with a 0.2 mm 2 x 47 μm Pb absorber an energy resolution of ΔE FWHM = 65 eV is obtained for 60 keV X-rays. (orig.)

  2. A Study of the Deformation, Network, and Aging of Polyethylene Oxide Films by Infrared Spectroscopy and Calorimetric Measurements

    Directory of Open Access Journals (Sweden)

    Carl Bergeron

    2012-01-01

    Full Text Available The calorimetric and infrared (IR spectroscopy measurements of polyethylene oxide (PEO are used to evaluate the deformation and relaxation that films experience during a temperature cycle (30°C–90°C–30°C. After melting, the intensity of some bands decreases by 10 to 70%. During the temperature cycle, the C–O band in the 1100 cm−1 region and the C–C–O deformation bands at 650 and 500 cm−1 show some new features. A network of cooperative oxygen-hydrogen interactions between the PEO chains form in films with special history, namely, in thermally treated films, in thin films prepared from gel forming solutions, and in thick films after aging. The interchain interaction network is suggested from the IR absorption bands in the 1200 and 900 cm−1 region and also from small bands at 1144 and 956 cm−1. The network seems absent or reduced in thin films. IR spectroscopy appears a sensitive technique to study chain conformations in PEO films and in other materials where order, disorder, and the formation of intermolecular interactions coexist.

  3. Evaluation of inductive heating energy of sub-size improved DPC-C conductor by calorimetric method

    International Nuclear Information System (INIS)

    Ito, Toshinobu; Koizumi, Norikiyo; Wakabayashi, Hiroshi; Miura, Yuushi; Fujisaki, Hiroshi; Matsui, Kunihiro; Takahashi, Yoshikazu; Tsuji, Hiroshi

    1996-08-01

    The improved DPC-U conductor consisting of 648 chrome plated NbTi strands was fabricated and its stability has been investigated using 1/24 sub-size conductor. In the stability experiment, the inductive heating method was applied to originate initial normal zone. Since it is difficult to calculate the inductive heating energy deposited on the conductor because of complicate geometry of the twisted multi-strand cable, inductive heating energy had to be experimentally evaluated using calorimetric method. The heating energy is in proportion to integration of square of an applied sinusoidal wave pulsed current over the heating period. The experimental result shows the proportional constants for the conductor and conduit are 2.062 x 10 -3 [J/A 2 s] and 0.771 x 10 -3 [J/A 2 s], respectively. The coupling between the eddy currents in the strands and conduit might take effect on the heating energy put in the strands. It was shown this effect was however small in this experiment. Consequently, the inductive heating energy applied in the strands was estimated to be the proportional constant of 1.291 x 10 -3 [J/A 2 s] from the difference of the heat energies in the conductor and conduit. (author)

  4. Comparison of the calculated neutral beam shinethrough of the Wendelstein VII-A injection with calorimetric measurements

    International Nuclear Information System (INIS)

    Penningsfeld, F.P.

    1987-06-01

    Density profiles of the Wendelstein VII-A plasma as measured by Thomson scattering are used to calculate the temporally and spatially varying power density of the neutral beam shinethrough on the torus calorimeter for several shot series. The total energy deposited by the three beam species is obtained by integrating the transmitted power density in space and time. This global quantity is compared with the calorimetric measurements routinely performed for each shot. The agreement between calculated and measured energy is found to be ΔE/E = 2.3 ± 11% confirming the error estimation for the NEUDEN program used, which was only slightly modified to calculate the power density transmitted in the target plane. From this good agreement it is concluded that the program contains a realistic beam model and reliable cross-sections for the beam attenuation which is important for further applications. Furthermore, the same comparison was done with old results of the ODIN code by analyzing the corresponding raw data as far as they could be recovered, obtaining a similarly good consistency. A possible increase of 10 to 20% of the beam stopping cross section which could be expected for Wendelstein VII-A conditions by the effect of multistep collision processes as suggested by Boley et al. is discussed also. (orig.)

  5. Mercury Continuous Emmission Monitor Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  6. Pru du 2S albumin or Pru du vicilin?

    Science.gov (United States)

    Garino, Cristiano; De Paolis, Angelo; Coïsson, Jean Daniel; Arlorio, Marco

    2015-06-01

    A short partial sequence of 28 amino acids is all the information we have so far about the putative allergen 2S albumin from almond. The aim of this work was to analyze this information using mainly bioinformatics tools, in order to verify its rightness. Based on the results reported in the paper describing this allergen from almond, we analyzed the original data of amino acids sequencing through available software. The degree of homology of the almond 12kDa protein with any other known 2S albumin appears to be much lower than the one reported in the paper that firstly described it. In a publicly available cDNA library we discovered an expressed sequence tag which translation generates a protein that perfectly matches both of the sequencing outputs described in the same paper. A further analysis indicated that the latter protein seems to belong to the vicilin superfamily rather than to the prolamin one. The fact that also vicilins are seed storage proteins known to be highly allergenic would explain the IgE reactivity originally observed. Based on our observations we suggest that the IgE reactive 12kDa protein from almond currently known as Pru du 2S albumin is in reality the cleaved N-terminal region of a 7S vicilin like protein. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Les effets du changement climatique dans le bassin du Congo : la ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    22 avr. 2016 ... Dans le bassin du fleuve Congo, plus de 80 % des habitants vivent exclusivement de l'agriculture, de la pêche, de l'élevage et de la cueillette, qui sont des activités largement tributaires du climat.

  8. Engagez-vous, devenez délégué(e) du personnel du CERN

    CERN Multimedia

    Staff Association

    2017-01-01

    Dans notre ECHO N° 275, nous avons annoncé les élections à venir au Conseil du personnel du CERN. Dans le présent ECHO, nous vous informons du lancement du processus des élections qui débute par le dépôt des candidatures. Tous les titulaires, boursiers et associés, qui sont aussi membres de l’Association du personnel, peuvent s’engager et déposer leur candidature entre le 11 septembre à 08 h 00 et le 13 octobre 2017 à 17 h 00. N’hésitez plus, remplissez le formulaire de candidature, présentez-vous aux élections au Conseil du personnel afin de pouvoir représenter et défendre vos collègues du personnel du CERN. ÊTRE DÉLÉGUÉ(E), C’EST QUOI ? Poser la question à plusieurs d...

  9. X-ray calibration qualities

    International Nuclear Information System (INIS)

    Burns, J.E.

    1998-01-01

    Since the recent publication of IAEA Technical Reports Series No. 374 ''Calibration of Dosimeters Used in Radiotheraphy'', there have been a number of queries about the origin of, and the rationale behind, the X-ray qualities recommended for calibration purposes. The simple answer is that these are the qualities derived at the UK National Physical Laboratory (NPL) in 1971 for calibration of therapy-level dosimeters and which are still in use for that purpose. As some SSDLs may have difficulties in adopting these exact combinations of kV and filtration. This paper discusses the basic ideas involved, and how to go about deriving a different series of qualities

  10. Aux marges du monde arabe

    Directory of Open Access Journals (Sweden)

    Hélène Thiollet

    2004-09-01

    Full Text Available L’étude des migrations contemporaines des Érythréens vers le Yémen au tournant des années quatre-vingt-dix permet d’observer les transformations des dynamiques régionales à l’œuvre dans le monde arabe. Les migrations sont un phénomène sensible aux différents aspects (politiques, économiques, culturels, géographiques de l’intégration régionale. Celle si est envisagée dans cet article à travers une approche doublement marginale : -la marginalité géographique de l’Érythrée arabo-africaine et du Yémen, économi­quement isolé dans la péninsule Arabique, -l’étude des migrations formelles et informelles, élément souvent marginal dans l’étude des institutions et des échanges qui constituent un système régional intégré. Cette étude est fondée sur une série d’entretiens menés au Yémen entre février et avril 2002 auprès des administrations yéménites et de la population érythréenne.

  11. Experimental study of the heat of combustion of electrical cables: Pitcairn/calorimetre test bench; Etude experimentale sur la combustion de cables electriques: le banc d`essais Pitcairn/calorimetre

    Energy Technology Data Exchange (ETDEWEB)

    Gautier, B.; Bosseboeuf, G.

    1995-11-01

    The R and D has been developing for about ten years, through the MAGIC software, a modeling program on the propagation of fire in power plants. The potential fuels in a power plant are mainly limited to the oils existing in engines and control systems, and electric cables. Those cables present a complex combustion due to their fire-resistant design. In order to study that combustion, two test benches, the PITCAIRN oven and the CALORIMETRE EDF/CNRS have been linked. This report presents briefly the experimental installation, then it comments on the first experimental data obtained with two types of samples, a PVC and an EPR-Hypalon cable. The tested cables are selected from those commonly used in French Nuclear Power Plants. They present complex components (fire-retarding chemical agents, mechanical reinforcement). The data show that the behavior of those cables cannot be reduced to a mass loss rate associated to a constant Heat of Combustion. The Heat of Combustion of the PVC cable tested varies little at the beginning of the pyrolysis from 5 kJ.g{sup -1} to 10 kJ.g{sup -1}, then increases quickly up to 30 kJ.g{sup -1}. In the same way, the EPR-Hypalon cable shows a continuous and slow increase of the Heat of Combustion from 1 kJ.g{sup -1} to 20 kJ.g{sup -1} during the pyrolysis, then rises quickly up to 40 kJ.g{sup -1} at the end. Those data corroborate the thesis of the dilution of flammable species by fire-retarding agents, which lower the Heat of combustion but seems to disappear at the end of the pyrolysis. (authors). 7 refs., 6 figs.

  12. Spectrophotometric calibration system for DECam

    Science.gov (United States)

    Rheault, J.-P.; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.; Williams, P.

    2012-09-01

    We describe a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 1nm wide tunable source to measure the instrumental response function of the telescope optics and detector from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function of the telescope during the 5 year survey. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes that allow us to measure the telescope throughput as a function of wavelength. Our system has a peak output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam.

  13. Recommended inorganic chemicals for calibration

    International Nuclear Information System (INIS)

    Moody, J.R.; Greenberg, R.R.; Pratt, K.W.; Rains, T.C.

    1988-01-01

    All analytical techniques depend on the use of calibration chemicals to relate analyte concentration to an instrumental parameter. A fundamental component in the preparation of calibration solutions is the weighing of a pure chemical or metal before preparing a solution standard. The analyst must be assured that the purity, stoichiometry, and assay of the chemical are known. These terms have different meanings, and each has an important influence. This report is intended to assist the analyst in the selection and use of chemical standards for instrumental calibration. Purity, stoichiometry, and preparation of solutions for different purposes are discussed, and a critical evaluation of the best materials available for each element is presented for use in preparing solutions or calibration standards. Information on the chemical form, source, purity, drying, and appropriate precautions is given. In some cases, multiple sources or chemical forms are available. Certain radioactive elements, the transuranic elements, and the noble gases are not considered

  14. Field calibration of cup anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, L.; Jensen, G.; Hansen, A.; Kirkegaard, P.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statistical significance of the calibration expressions. It is concluded that the method has the advantage that many anemometers can be calibrated accurately with a minimum of work and cost. The obvious disadvantage is that the calibration of a set of anemometers may take more than one month in order to have wind speeds covering a sufficiently large magnitude range in a wind direction sector where we can be sure that the instruments are exposed to identical, simultaneous wind flows. Another main conclusion is that statistical uncertainty must be carefully evaluated since the individual 10 minute wind-speed averages are not statistically independent. (au)

  15. Calibration of radiation monitoring instruments

    International Nuclear Information System (INIS)

    1973-01-01

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  16. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  17. Calibration of radiation monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-12-31

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  18. Rotary mode system initial instrument calibration

    International Nuclear Information System (INIS)

    Johns, B.R.

    1994-01-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files

  19. Pressures Detector Calibration and Measurement

    CERN Document Server

    AUTHOR|(CDS)2156315

    2016-01-01

    This is report of my first and second projects (of 3) in NA61. I did data taking and analysis in order to do calibration of pressure detectors and verified it. I analyzed the data by ROOT software using the C ++ programming language. The first part of my project was determination of calibration factor of pressure sensors. Based on that result, I examined the relation between pressure drop, gas flow rate of in paper filter and its diameter.

  20. Cirque du Monde as a health intervention

    Science.gov (United States)

    Fournier, Cynthia; Drouin, Mélodie-Anne; Marcoux, Jérémie; Garel, Patricia; Bochud, Emmanuel; Théberge, Julie; Aubertin, Patrice; Favreau, Gil; Fleet, Richard

    2014-01-01

    Abstract Objective To present Cirque du Soleil’s social circus program, Cirque du Monde, to explore its potential as a primary health care tool for family physicians. Data sources A review of the literature in PubMed, the Cochrane Library, PsycINFO, LaPresse, Eureka, Google Scholar, and Érudit using the key words circus, social circus, Cirque du Monde, and Cirque du Soleil; a Montreal-based initiative, Espace Transition, modeled on Cirque du Monde; and personal communication with Cirque du Soleil’s Social Circus Training Advisor. Study selection The first 50 articles or websites identified for each key word in each of the databases were examined on the basis of their titles and abstracts in the case of articles, and on the basis of their titles and page content in the case of websites. Articles and websites that explored an aspect of social circuses or that described an intervention that involved circuses were then retained for analysis. Because all literature on social circuses was searched, no criterion for year of publication was used. Synthesis No articles on the social circus as a health intervention were found. One study on the use of the circus as an intervention in schools was identified. It demonstrated an increase in self-esteem in the children who took part. One study on the use of the circus in a First Nations community was found; it contained nonspecific, qualitative findings. The other articles identified were merely descriptions of social circuses. One website was identified on the use of the social circus to help youth who had been treated in a hospital setting for major psychiatric disorders to re-enter the community. The team in the pediatric psychiatry department at Centre Hospitalier Universitaire Sainte-Justine, the children’s hospital in Montreal, Que, was contacted; they were leading this project, called Espace Transition. The unpublished preliminary findings of its pilot project demonstrate substantial improvements in overall patient

  1. The KLOE online calibration system

    International Nuclear Information System (INIS)

    Pasqualucci, E.; Alexander, G.; Aloisio, A.

    2001-01-01

    Based on all the features of the KLOE online software, the online calibration system performs current calibration quality checking in real time and starts automatically new calibration procedures when needed. A calibration manager process controls the system, implementing the interface to the online system, receiving information from the run control and translating its state transitions to a separate state machine. It acts as a 'calibration run controller' and performs failure recovery when requested by a set of process checkers. The core of the system is a multi-threaded OO histogram server that receives histogramming commands by remote processes and operates on local ROOT histograms. A client library and C, fortran and C++ application interface libraries allow the user to connect and define his own histogram or read histograms owned by others using an book-like interface. Several calibration processes running in parallel in a distributed, multiplatform environment can fill the same histograms, allowing fast external information check. A monitor thread allow remote browsing for visual inspection. Pre-filtered data are read in non-privileged spy mode from the data acquisition system via the Kloe Integrated Dataflow. The main characteristics of the system are presented

  2. Établissements recevant du public

    CERN Document Server

    2014-01-01

    Synthèse pour les installations électriques, des règles de sécurité contre les risques d’incendie et de panique dans les établissements recevant du public (ERP), selon l’arrêté du 25 juin 1980 modifié. L'ouvrage traite à la fois des dispositions communes aux établissements du 1er groupe (1ère à 4ème catégorie), du 2ème groupe (5ème catégorie) et des règles particulières applicables aux différents types d'établissements (structures d'accueil pour personnes âgées ou handicapées, hôtels, magasins de vente, restaurants et débit de boisson, établissements de soins, administration, châpiteaux, etc...) Sont ainsi notamment traités, dans le cadre des dispositions communes aux établissements du 1er groupe, pour les installations électriques normales : les installations des appareils, tableaux et canalisations, les locaux électriques et installation de machines, l'éclairage normal des locaux accessibles au public, le chauffage et la ventilation, l'installation d'eau chaude sanita...

  3. Sådan kan du bruge optioner og futures

    DEFF Research Database (Denmark)

    Kohl, Niklas

    2017-01-01

    Masterclass. Har du brug for at forsikre værdierne i din portefølje i en periode, hvor du forventer stor uro på finansmarkederne, kan du gøre det med optioner eller futures. Her kan du læse om de forskellige typer – og om de muligheder de giver dig.......Masterclass. Har du brug for at forsikre værdierne i din portefølje i en periode, hvor du forventer stor uro på finansmarkederne, kan du gøre det med optioner eller futures. Her kan du læse om de forskellige typer – og om de muligheder de giver dig....

  4. Thermomechanical and calorimetric behaviours of supported glass-forming films: A study based on thermodynamics with internal variables

    International Nuclear Information System (INIS)

    Lion, Alexander; Engelhard, Marco; Johlitz, Michael

    2012-01-01

    In order to understand the temperature-dependent response behaviour of thin thermoviscoelastic films which are deposited on relative stiff but thermally deformable substrates it is important to consider the lateral geometric constraints. They are generated by differences in the thermal expansion properties between the substrate and the film and provoke internal stresses. Since glass-forming materials exhibit distinct temperature history-dependent thermal expansion and calorimetric properties, primarily in the vicinity of the glass transition, the situation is rather complicated. In this article, a recently developed three-dimensional model of thermodynamics with internal variables is applied and adapted to simulate this type of behaviour. Explicit relations are obtained for the specific heat of the film, the normal strain and the lateral stresses. Numerical simulations demonstrate that the magnitude of the internal stress at temperatures below the glass transition depends strongly on the cooling rate. It is also shown that the specific heat of the supported film is principally different from the isobaric specific heat of the bulk material: the glassy limit of the specific heat of the film is reduced but the glass transition temperature is almost uninfluenced. The simulated behaviour is in accordance with experimental observations from literature. - Highlights: ► For the specific heat, stress and strain of the film, explicit equations were derived. ► The constraints of the substrate reduce the glassy limit of specific heat of the film. ► Glass transition temperatures of free bulk material and supported film are equal. ► Simulations are in good agreement with experimental observations from literature.

  5. Calorimetric low-temperature detectors on semiconductor base for the energy-resolving detection of heavy ions

    International Nuclear Information System (INIS)

    Kienlin, A. von.

    1994-01-01

    In the framework of this thesis for the first time calorimetric low-temperature detectors for the energy-resolving detection of heavy ions were developed and successfully applied. Constructed were two different detector types, which work both with a semiconductor thermistor. The temperature increasement effected by a particle incidence is read out. In the first detector type the thermistor was simutaneously used as absorber. The thickness of the germanium crystals was sufficient in order to stop the studied heavy ions completely. In the second type, a composed calorimeter, a sapphire crystal, which was glued on a germanium thermistor, served as absorber for the incident heavy ions. The working point of the calorimeter lies in the temperature range (1.2-4.2 K), which is reachable with a pumped 4 He cryostat. The temperatur increasement of the calorimeter amounts after the incidence of a single α particle about 20-30 μK and that after a heavy ion incidence up to some mK. An absolute energy resolution of 400-500 keV was reached. In nine beam times the calorimeters were irradiated by heavy ions ( 20 Ne, 40 Ar, 136 Xe, 208 Pb, 209 Bi) of different energies (3.6 MeV/nucleon< E<12.5 MeV/nucleon) elastically scattered from gold foils. In the pulse height spectra of the first detector type relatively broad, complex-structurated line shapes were observed. By systematic measurements dependences of the complex line structures on operational parameters of the detector, the detector temperature, and the position of the incident particle could be detected. Together with the results of further experiments a possible interpretation of these phenomena is presented. Contrarily to the complex line structures of the pure germanium thermistor the line shapes in the pulse height spectra, which were taken up in a composite germanium/sapphire calorimeter, are narrow and Gauss-shaped

  6. Thermogravimetric, Calorimetric, and Structural Studies of the Co3 O4 /CoO Oxidation/Reduction Reaction

    Science.gov (United States)

    Unruh, Karl; Cichocki, Ronald; Kelly, Brian; Poirier, Gerald

    2015-03-01

    To better assess the potential of cobalt oxide for thermal energy storage (TES), the Co3O4/CoO oxidation/reduction reaction has been studied by thermogravimetric (TGA), calorimetric (DSC), and x-ray diffraction (XRD) measurements in N2 and atmospheric air environments. TGA measurements showed an abrupt mass loss of about 6.6% in both N2 and air, consistent with the stoichiometric reduction of Co3O4 to CoO and structural measurements. The onset temperature of the reduction of Co3O4 in air was only weakly dependent on the sample heating rate and occurred at about 910 °C. The onset temperature for the oxidation of CoO varied between about 850 and 875 °C for cooling rates between 1 and 20 °C/min, but complete re-conversion to Co3O4 could only be achieved at the slowest cooling rates. Due to the dependence of the rate constant on the oxygen partial pressure, the oxidation of Co3O4 in a N2 environment occurred at temperatures between about 775 and 825 °C for heating rates between 1 and 20 °C/min and no subsequent re-oxidation of the reduced Co3O4 was observed on cooling to room temperature. In conjunction with a measured transition heat of about 600 J/g of Co3O4, these measurements indicate that cobalt oxide is a viable TES material.

  7. Thermomechanical and calorimetric behaviours of supported glass-forming films: A study based on thermodynamics with internal variables

    Energy Technology Data Exchange (ETDEWEB)

    Lion, Alexander, E-mail: alexander.lion@unibw.de; Engelhard, Marco; Johlitz, Michael

    2012-11-01

    In order to understand the temperature-dependent response behaviour of thin thermoviscoelastic films which are deposited on relative stiff but thermally deformable substrates it is important to consider the lateral geometric constraints. They are generated by differences in the thermal expansion properties between the substrate and the film and provoke internal stresses. Since glass-forming materials exhibit distinct temperature history-dependent thermal expansion and calorimetric properties, primarily in the vicinity of the glass transition, the situation is rather complicated. In this article, a recently developed three-dimensional model of thermodynamics with internal variables is applied and adapted to simulate this type of behaviour. Explicit relations are obtained for the specific heat of the film, the normal strain and the lateral stresses. Numerical simulations demonstrate that the magnitude of the internal stress at temperatures below the glass transition depends strongly on the cooling rate. It is also shown that the specific heat of the supported film is principally different from the isobaric specific heat of the bulk material: the glassy limit of the specific heat of the film is reduced but the glass transition temperature is almost uninfluenced. The simulated behaviour is in accordance with experimental observations from literature. - Highlights: Black-Right-Pointing-Pointer For the specific heat, stress and strain of the film, explicit equations were derived. Black-Right-Pointing-Pointer The constraints of the substrate reduce the glassy limit of specific heat of the film. Black-Right-Pointing-Pointer Glass transition temperatures of free bulk material and supported film are equal. Black-Right-Pointing-Pointer Simulations are in good agreement with experimental observations from literature.

  8. Evaluation of inductive heating energy of a PF insert coil conductor by the calorimetric method (Contract research)

    International Nuclear Information System (INIS)

    Matsui, Kunihiro; Nabara, Yoshihiro; Nunoya, Yoshihiko; Koizumi, Norikiyo; Okuno, Kiyoshi

    2009-02-01

    The PF Insert Coil is a single layer solenoid coil using a superconducting conductor designed for ITER, housed in a Poloidal field coil and installed in the bore of the CS Model Coil. A stability test of the conductor will be performed in a magnetic field generated by the CS Model Coil. In this test, the inductive heat of an inductive heater attached to the conductor will be applied to initiate a normal zone in the conductor. Since the conductor for the PF Insert Coil is a cable-in-conduit conductor, it is quite difficult to estimate inductive heating energy theoretically. Thus, the inductive heating energy is measured experimentally by the calorimetric method. The heating energy is in proportion to a constant multiplied by the integrated square of an applied sinusoidal current wave over the heating period. Experimental results show that the proportional constants of the conductor, cable, conduit and dummy conductor are 0.138 [J/A 2 s], 0.028 [J/A 2 s], 0.118 [J/A 2 s] and 0.009 [J/A 2 s], respectively. The first three denote not only the inductive heating but also the joule heating of the inductive heater. The final value denotes joule heating only. Therefore, subtracting the first three constants by the last one, the proportional constants of inductive heating generated in the conductor, cable and conduit are estimated to be 0.129 [J/A 2 s], 0.019 [J/A 2 s] and 0.109 [J/A 2 s], respectively. (author)

  9. Science et technologie du collage

    CERN Document Server

    Cognard, Jacques

    2003-01-01

    L'Homme a su coller avant de savoir écrire et compter. Le collage est en effet l'une des premières techniques d'assemblage d'une structure que l'homme ait utilisée, technique qui n'est devenue science qu'au début du 20e siècle avec la fabrication des premières colles synthétiques. Cette science de l'adhésion a considérablement progressé ces dix dernières années et ce livre présente l'état actuel des connaissances en décrivant les progrès considérables réalisés dans la compréhension des phénomènes fondamentaux qui font qu'un collage tient bien et durablement. Après l'exposé des bases scientifiques nécessaires et des modèles théoriques récents, l'auteur introduit la distinction entre collages faibles et collages forts puis expose les difficultés rencontrées dans les cas pratiques, difficultés souvent dues à la complexité de la chimie des surfaces et des réactions surface-polymère. L'ouvrage se termine par la présentation de quelques applications récentes, en particulier dans...

  10. Investigation on calibration parameter of mammography calibration facilities at MINT

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Wan Hazlinda Ismail; Md Saion Salikin; Muhammad Jamal Md Isa; Azuhar Ripin; Norriza Mohd Isa

    2004-01-01

    A mammography calibration facility has been established in the Medical Physics Laboratory, Malaysian Institute for Nuclear Technology Research (MINT). The calibration facility is established at the national level mainly to provide calibration services for radiation measuring test instruments or test tools used in quality assurance programme in mammography, which is being implemented in Malaysia. One of the accepted parameters that determine the quality of a radiation beam is the homogeneity coefficient. It is determined from the values of the 1 st and 2 nd Half Value Layer (HVL). In this paper, the consistency of the mammography machine beam qualities that is available in MINT, is investigated and presented. For calibration purposes, five radiation qualities namely 23, 25, 28, 30 and 35 kV, selectable from the control panel of the X-ray machine is used. Important parameters that are set for this calibration facility are exposure time, tube current, focal spot to detector distance (FDD) and beam size at specific distance. The values of homogeneity coefficient of this laboratory for the past few years tip to now be presented in this paper. Backscatter radiations are also considered in this investigation. (Author)

  11. Accroissement du recours aux politiques fiscales dans la lutte ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Incidence de la hausse des taxes sur le tabac et du prix des produits du tabac en Ukraine, en Russie et au Bélarus. La recherche destinée aux responsables des politiques de l'Ukraine, de la Russie et du Bélarus mettra en évidence la façon dont les mesures de taxation des produits du tabac peuvent contribuer.

  12. Couzeix – Les Terres du Puy Dieu

    OpenAIRE

    Maniquet, Christophe

    2013-01-01

    Identifiant de l'opération archéologique : 122281 Date de l'opération : 2005 (EX) Dans le cadre du projet de construction d'un lotissement constitué de trois pavillons au lieu-dit « Les Terres du Puy Dieu », un diagnostic archéologique a été prescrit par le service régional de l'Archéologie. En effet, plusieurs sites archéologiques avaient été inventoriés à proximité immédiate de la zone d'intervention. On notera, en particulier, la découverte en 1982, près du Puy Dieu, au cours de travaux de...

  13. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  14. Profils des porteurs du VIH/SIDA au début du traitement ...

    African Journals Online (AJOL)

    But : Décrire les profils des porteurs de VIH/sida au début du traitement antirétroviral. Matériels et méthode: Les dossiers des porteurs du VIH/sida de la région maritime ont été analysés de mai 2008 à avril 2009 par le comité thérapeutique. Résultats: Parmi les 641 dossiers analysés, 67,40% venaient du district de Yoto.

  15. Distribution spatiale du singe à ventre rouge, Cercopithecus ...

    African Journals Online (AJOL)

    danger et endémique du Dahomey Gap est très peu documenté au Togo. Pour connaître sa ..... chaque secteur prospecté ainsi que celui du complexe en entier. ..... 2008-009 portant loi-cadre sur l'environnement au Togo. JO du 06 juin. 2008.

  16. Directeur, Gestion du risque et audit interne | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Résumé des fonctions En qualité de dirigeant principal de l'audit (DPA), ... président du Centre et au président du Comité des finances et de l'audit une assurance et des ... Il fournit des services de gestion du risque organisationnel et d'autres ...

  17. Compatibilidad química por calorimetría diferencial de barrido y termogravimetría del auranofin tabletas 3 mg

    Directory of Open Access Journals (Sweden)

    Luis Octavio Martínez Álvarez

    2011-03-01

    Full Text Available Como parte de la pre-estabilidad de la preformulación de auranofin tabletas, se realizó un estudio de compatibilidad química, para lo cual se emplearon técnicas de análisis térmico como la calorimetría diferencial de barrido y la termogravimetría. Previo a dichos estudios se caracterizó térmicamente por calorimetría diferencial de barrido el principio activo y cada uno de los excipientes. Posteriormente se procedió a la realización del estudio de compatibilidad química, mediante la preparación de mezclas físicas binarias entre el principio activo y cada uno de los excipientes. Se detectó por ambos métodos que el principio activo tuvo una transición física de fusión, no reportada en la literatura, lo que permitió poder calcular su pureza por calorimetría diferencial de barrido. Mediante la técnica calorimétrica fue posible inferir la ausencia de incompatibilidad química entre el principio activo y los excipientes estudiados. Además, mediante el cálculo de la energía de activación se estableció el siguiente orden de estabilidad térmica: auranofin:PVP> auranofin:lactosa> auranofin:explotab> auranofin:estearato> auranofin:aerosil> auranofin:celulosa, por lo que se recomienda el uso de estos excipientes en la elaboración de la formulación farmacéutica.

  18. The impact of a low glycaemic index (GI) diet on simultaneous measurements of blood glucose and fat oxidation: A whole body calorimetric study.

    Science.gov (United States)

    Kaur, Bhupinder; Quek Yu Chin, Rina; Camps, Stefan; Henry, Christiani Jeyakumar

    2016-06-01

    Low glycaemic index (GI) foods are known to minimize large fluctuations in blood glucose levels and have been suggested to increase fat oxidation. The objective of this study was to simultaneously investigate glucose excursion and substrate oxidation in a whole body calorimetre when Chinese male subjects were provided a low or high GI meal. In a randomized, controlled crossover non blind design, 12 healthy Chinese male adults (BMI 21.8 ± 1.3 kgm -2 ) attended two sessions consisting of either four low or high glycaemic meals (LGI vs HGI). Breakfast, lunch and snack were consumed in a whole body calorimetre while dinner was consumed at home. Daily changes in glycaemic response (GR) and postprandial GR responses were measured using a continuous glucose monitoring system. The GR was further calculated to obtain the incremental area under the curve (iAUC) for glucose concentrations. Glycaemic variability was calculated as mean amplitude of glycaemic excursion (MAGE). Substrate oxidation was calculated by measuring respiratory quotient and urine nitrogen excretion. After LGI meals in the whole body calorimetre, iAUC for glucose (P = 0.008) was lower compared to the HGI session. The HGI treatment produced a significantly greater MAGE than the LGI treatment over the 24 hour period (P fat oxidation and lower carbohydrate oxidation were observed following breakfast and lunch when comparing LGI to HGI (P fat oxidation over carbohydrate oxidation when compared to HGI mixed meals. The consumption of low GI meals may be a strategic approach in improving overall glycaemia and increasing fat oxidation in Asians consuming a high carbohydrate diet.

  19. Webzzle : paradoxal confort du confinement.

    Directory of Open Access Journals (Sweden)

    Marc Dumont

    2007-06-01

    Full Text Available La plupart des agences de « news » technologiques viennent de se faire l’écho du développement de Webzzle , un nouveau moteur de recherche dit « collaboratif ». Ce cas est tout à fait intéressant parce qu’il permet de pointer rapidement quelques grands enjeux du Web 2 que risquent souvent de dissimuler la jungle sémantique et l’enthousiasme qui l’entourent. Pour quelles raisons ? Rappelons d’abord les deux principales perspectives ouvertes par cette nouvelle ...

  20. Krypton purification (1961); Purification du krypton (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Larher, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Institut Fourier, 38 - Grenoble (France)

    1961-07-01

    The amount of xenon in otherwise very pure krypton can be reduced from 1.5 to 0.0025 per cent approximately by passage through an activated carbon column at dry-ice temperature. The circulation of the krypton is effected by condensing at -196 deg. C and then evaporating. (author) [French] Le taux de xenon dans du krypton par ailleurs tres pur est ramene de 1,5 pour cent a 0,0025 pour cent environ au cours d'un passage a travers une colonne de charbon actif a la temperature de la carboglace. La circulation du krypton se fait par condensation a -196 deg. C, puis evaporation. (auteur)

  1. FTIR Calibration Methods and Issues

    Science.gov (United States)

    Perron, Gaetan

    Over the past 10 years, several space-borne FTIR missions were launched for atmospheric research, environmental monitoring and meteorology. One can think of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) launched by the European Space Agency, the Atmospheric Chemistry Experiment (ACE) launched by the Canadian Space Agency, the Tropospheric Emission Spectrometer (TES) launched by NASA and the Infrared Atmospheric Sounding Interferometer (IASI) launched by Eumetsat in Europe. Others are near to be launched, namely the Cross-track Infrared Sounder (CrIS) from the Integrated Program Of- fice in the United States and the Thermal And Near infrared Sensor for carbon Observation (TANSO) from the Japan Aerospace Exploration Agency. Moreover, several missions under definition foresee the use of this technology as sensor, e.g. Meteosat Third Generation (MTG), Eumetsat Polar System (EPS) and the Premier mission, one of the six candidates of the next ESA Earth Explorer Core Mission. In order to produce good quality products, calibration is essential. Calibrated data is the output of three main sub-systems that are tightly coupled: the instrument, the calibration targets and the level 1B processor. Calibration requirements must be carefully defined and propagated to each sub-system. Often, they are carried out by different parties which add to the complexity. Under budget and schedule pressure, some aspects are sometimes neglected and jeopardized final quality. For space-borne FTIR, level 1B outputs are spectra that are radiometrically, spectrally calibrated and geolocated. Radiometric calibration means to assign an intensity value in units to the y-axis. Spectral calibration means to assign to the x-axis the proper frequency value in units. Finally, geolocated means to assign a target position over the earth geoid i.e. longitude, latitude and altitude. This paper will present calibration methods and issues related to space-borne FTIR missions, e.g. two

  2. Automatic calibration of gamma spectrometers

    International Nuclear Information System (INIS)

    Tluchor, D.; Jiranek, V.

    1989-01-01

    The principle is described of energy calibration of the spectrometric path based on the measurement of the standard of one radionuclide or a set of them. The entire computer-aided process is divided into three main steps, viz.: the insertion of the calibration standard by the operator; the start of the calibration program; energy calibration by the computer. The program was selected such that the spectrum identification should not depend on adjustment of the digital or analog elements of the gamma spectrometric measuring path. The ECL program is described for automatic energy calibration as is its control, the organization of data file ECL.DAT and the necessary hardware support. The computer-multichannel analyzer communication was provided using an interface pair of Canberra 8673V and Canberra 8573 operating in the RS-422 standard. All subroutines for communication with the multichannel analyzer were written in MACRO 11 while the main program and the other subroutines were written in FORTRAN-77. (E.J.). 1 tab., 4 refs

  3. Calibration of the SNO+ experiment

    Science.gov (United States)

    Maneira, J.; Falk, E.; Leming, E.; Peeters, S.; SNO+ Collaboration.

    2017-09-01

    The main goal of the SNO+ experiment is to perform a low-background and high-isotope-mass search for neutrinoless double-beta decay, employing 780 tonnes of liquid scintillator loaded with tellurium, in its initial phase at 0.5% by mass for a total mass of 1330 kg of 130Te. The SNO+ physics program includes also measurements of geo- and reactor neutrinos, supernova and solar neutrinos. Calibrations are an essential component of the SNO+ data-taking and analysis plan. The achievement of the physics goals requires both an extensive and regular calibration. This serves several goals: the measurement of several detector parameters, the validation of the simulation model and the constraint of systematic uncertainties on the reconstruction and particle identification algorithms. SNO+ faces stringent radiopurity requirements which, in turn, largely determine the materials selection, sealing and overall design of both the sources and deployment systems. In fact, to avoid frequent access to the inner volume of the detector, several permanent optical calibration systems have been developed and installed outside that volume. At the same time, the calibration source internal deployment system was re-designed as a fully sealed system, with more stringent material selection, but following the same working principle as the system used in SNO. This poster described the overall SNO+ calibration strategy, discussed the several new and innovative sources, both optical and radioactive, and covered the developments on source deployment systems.

  4. Calibration strategies for the Cherenkov Telescope Array

    NARCIS (Netherlands)

    Gaug, M.; Berge, D.; Daniel, M.; Doro, M.; Förster, A.; Hofmann, W.; Maccarone, M.C.; Parsons, D.; de los Reyes Lopez, R.; van Eldik, C.

    2014-01-01

    The Central Calibration Facilities workpackage of the Cherenkov Telescope Array (CTA) observatory for very high energy gamma ray astronomy defines the overall calibration strategy of the array, develops dedicated hardware and software for the overall array calibration and coordinates the calibration

  5. Effets de la microdose sur la production du niébé, du mil et du ...

    African Journals Online (AJOL)

    respectivement pour le sorgho, le mil et le niébé comparativement au témoin. La microdose a été .... Les prix utilisés sont celui du marché local au moment des semis pour les engrais soit 17500 FCFA pour NPK et ..... Projet « Transfert de la.

  6. L’ombre du Condor

    Directory of Open Access Journals (Sweden)

    Franck Gaudichaud

    2003-09-01

    Full Text Available Si l’on observe aujourd’hui, avec un regard d’historien, le Cône Sud à la fin des années soixante soixante-dix et que par, la suite, on tourne une page de quelques années, pour fixer la même partie du monde, le constat est sans appel : le sous-continent latino-américain est passé, en général, d’une phase de forte mobilisation et politisation sociale, montée en puissance de partis et organisations révolutionnaires, surgissements de gouvernements populistes de gauche ou progressistes – appelant à une rupture avec l’impérialisme –, à un reflux généralisé du mouvement ouvrier, une ère de violence politique étatisée, la destruction massive de tous les espaces d’expression et de participation démocratiques, l’écrasement physique et idéologique sans relâche des militants et mouvements révolutionnaires, la mise en place de modèles économiques capitalistes dirigistes puis/ou néolibéraux. Que s’est-il passé ? Quel fil conducteur a été rompu et par quels moyens l’Amérique Latine a été conduite à ce reflux des luttes sociales ? Pour répondre à cette question, nous nous contenterons dans cet article de focaliser notre objectif sur un aspect spécifique et essentiel de ce retournement de tendance que vit alors l���Amérique Latine : celui de la mise en place d’un terrorisme d’Etat contre-révolutionnaire transnational, appuyé par l’impérialisme américain, nommé « l’Opération Condor ». Dans cet article, il s’agit de montrer le fonctionnement d’un terrorisme hégémonique dont l’impact sur les sociétés latino-américaines est considérable en termes de destruction du mouvement social, des activités culturelles et de l’ensemble de la vie sociale et politique qui restent marquées, encore aujourd’hui à des degrés divers, par la violence, la peur et l’atomisation structurelle.Si miramos hoy en día, desde una perspectiva histórica, el Cono Sur hacia finales de

  7. Étude de la qualité des eaux usées des deux retenues du bassin du ...

    African Journals Online (AJOL)

    SARAH

    31 mai 2017 ... Gourou au carrefour de l'Indénié à Abidjan en 2012. 11138. Journal of Applied .... retenues sont nées du projet de gestion intégrée du bassin du Gourou (CI-FAD, ..... Contrôle de la qualité microbiologique des eaux usées ...

  8. 26 Calcul multi-caractéristique du coût du non-qualité via la fonction ...

    African Journals Online (AJOL)

    PR BOKO

    Le coût du non - qualité (CNQ) est un indicateur permettant l'estimation de la marge ..... multicritères de Taguchi en fonction de l'évolution du poids et capacité du ... A Scheduling Example; International Journal of Information and Management.

  9. Le Flaubert de Charles Du Bos

    Directory of Open Access Journals (Sweden)

    Jacques Neefs

    2009-01-01

    Full Text Available Charles Du Bos a porté une attention constante à l’œuvre de Flaubert (à l’exclusion de Bouvard et Pécuchet qui semble ne pas exister pour lui, à Madame Bovary et à L’Éducation sentimentale en particulier. La mise en relation de son étude : « Sur le milieu intérieur chez Flaubert », écrite en 1921, avec des textes du Journal de 1923 et de 1937, les rapprochements avec Gogol, Thomas Hardy, Tolstoï, Baudelaire, Henry James qui traversent les écrits de Du Bos, permettent de suivre ce que celui-ci décrit comme « l’expérience spirituelle » d’une matérialité comprise dans la conquête de la triple exigence du Beau, du Vivant et du Vrai. Du Bos décèle la force de l’œuvre de Flaubert dans la « disproportion » du style, et dans la puissance d’absorption qui fait la densité de cette prose, et qui désigne un extraordinaire travail de conversion. L’obscure expérience spirituelle ainsi poursuivie est celle d’un absolu de l’art, expérience paradoxale d’un « mystique qui ne croit à rien » (comme se désignait Flaubert lui-même, que le critique lie à une interrogation sur sa propre conversion.Charles Du Bos devoted an unflagging attention to Flaubert’s work (except for Bouvard et Pécuchet, which, apparently, according to him did not exist, to Madame Bovary and in particular L’Éducation sentimentale. The connection between his essay “Sur le milieu intérieur chez Flaubert”, written in 1921, and extracts from his Journal, from 1923 to 1937, the comparisons with Gogol, Thomas Hardy, Tolstoy, Baudelaire, and Henry James that run through the writings of Du Bos, allow us to follow what he terms “the spiritual experience” of a materiality encompassed in the conquest of the triple demand of the Beautiful, the Living, the Truth. Du Bos detects the power of Flaubert’s work in the “disproportion” of his style, and the power of absorption that forms the density of his prose, showing an

  10. Calibration pipeline for VIR data

    Science.gov (United States)

    Carraro, F.; Fonte, S.; Coradini, A.; Filacchione, G.; de Sanctis, M. C.; Ammannito, E.; Capria, M. T.; Cartacci, M.; Noschese, R.; Tosi, F.; Capaccioni, F.

    2011-10-01

    During the second quarter of 2011 VIR-MS (VIS and IR Mapping Spectrometer) [1] aboard Dawn mission [2] has approached Vesta in order to start a long period of acquisitions that will end at the beginning of 2012. Data acquired by each instrument always require a calibration process in order to remove all the instrument effects that could affect the scientific evaluations and analysis. VIR-MS instrument team has realized a calibration pipeline which has the goal of producing calibrated (1b level) data starting from the raw (1a level) ones. The other goal of the tool has been the check of the goodness of acquired data by means of the evaluation of a series of minimum requisites of each data file, such as the percentage of the saturated pixels, the presence of spikes or the mean S/N ratio of each qube.

  11. Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Faber, M.H.; Sørensen, John Dalsgaard

    2003-01-01

    The present paper addresses fundamental concepts of reliability based code calibration. First basic principles of structural reliability theory are introduced and it is shown how the results of FORM based reliability analysis may be related to partial safety factors and characteristic values....... Thereafter the code calibration problem is presented in its principal decision theoretical form and it is discussed how acceptable levels of failure probability (or target reliabilities) may be established. Furthermore suggested values for acceptable annual failure probabilities are given for ultimate...... and serviceability limit states. Finally the paper describes the Joint Committee on Structural Safety (JCSS) recommended procedure - CodeCal - for the practical implementation of reliability based code calibration of LRFD based design codes....

  12. Radiation protection dosimetry and calibrations

    International Nuclear Information System (INIS)

    Verhavere, Ph.

    2007-01-01

    At the SCK-CEN different specialised services are delivered for a whole range of external and internal customers in the radiation protection area. For the expertise group of radiation protection dosimetry and calibrations, these services are organized in four different laboratories: dosimetry, anthropogammametry, nuclear calibrations and non-nuclear calibrations. The services are given by a dedicated technical staff who has experience in the handling of routine and specialised cases. The scientific research that is performed by the expertise group makes sure that state-of-the-art techniques are being used, and that constant improvements and developments are implemented. Quality Assurance is an important aspect for the different services, and accreditation according national and international standards is achieved for all laboratories

  13. XRD alignment, calibration and performance

    International Nuclear Information System (INIS)

    Davy, L.

    2002-01-01

    Full text: The quality of any diffractometer system is very much dependent on the alignment, calibration and performance. The three subjects are very much related. Firstly, you must know how to carry out the full diffractometer alignment. XRD alignment is easy once you know how. The presentation will show you step by step to carry out the full alignment. Secondly, you need to know how to calibrate the diffractometer system. The presentation will show you how to calibrate the goniometer, detector etc. Thirdly, to prove the system is working within the manufacturer specification. The presentation will show you how to carry out the resolution, reproducibility and linearity test. Copyright (2002) Australian X-ray Analytical Association Inc

  14. Analyses de la dégradation du lac Kinkony pour la conservation du ...

    African Journals Online (AJOL)

    Le lac Kinkony fait partie des habitats clefs pour la biodiversité du Complexe des ... provide favoured habitat for numerous endemic and endangered avian, fish ... on fauna is essential for developing regional conservation and natural resource ...

  15. Consolidation du leadership en recherche en écosanté en Asie du ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    1 juin 2016 ... Financée par le CRDI, l'Initiative de renforcement du leadership en recherche en écosanté en Asie du Sud‑Est appuie l'exécution, dans la région, de travaux de recherche qui visent à permettre de mieux comprendre les effets de la transformation de l'agriculture sur les écosystèmes et sur la santé humaine ...

  16. Accroissement de la compétitivité du Kenya dans l'économie du ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    La promulgation par le Kenya du Science, Technology and Innovation Bill, 2012 confirme l'intérêt et la volonté du gouvernement de mettre en oeuvre désormais un programme de développement fondé sur la science. La loi offre aussi au CRDI l'occasion d'appuyer le programme de recherche et de politiques de la nouvelle ...

  17. Effets du travail du sol sur le comportement chimique et biologique ...

    African Journals Online (AJOL)

    SARAH

    31 juil. 2017 ... RESUME. Objectif : L'objectif de cette étude est de comparer les effets de six techniques culturales de mise en place du blé tendre sur certaines propriétés chimiques et biologiques du sol et les conséquences sur le rendement grain et ses composantes dans la région «non chernozem» en 7ème années ...

  18. OGM : vers une définition commune du contenu du problème ?

    Directory of Open Access Journals (Sweden)

    Icart Jean-Claude

    2001-07-01

    Full Text Available Les divergences croissantes depuis des années entre experts, responsables économiques, et acteurs sociaux et « citoyens » au sujet des OGM, ont pu être analysées à juste titre, comme exprimant la difficulté de dégager une « définition commune du contenu du problème »1.

  19. Évaluation du nouveau programme d'études du College of Health ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Ces changements étaient jugés nécessaires pour préparer les professionnels de la santé aux nouvelles exigences de la prestation de services de santé décentralisés, pour juguler les nouvelles pandémies comme celles du VIH/sida et du virus Ébola, ainsi que pour répondre aux besoins des malades dans les zones ...

  20. Une force venant du futur chercherait à saboter l'expérience du LHC...

    CERN Multimedia

    Scappaticci, Bruno

    2009-01-01

    "A quelques jours de la reprise de l'expérience du LHC, on ne parle plus de la menace d'un trou noir, mais deux physicines souteinnent aujourd'hui une tout autres hypothèse: la nature, depuis le futur, va continuer de contrarier les travaux du Cern, afin d'éviter à l'Homme de mettre le doigt là où il ne faut pas..." (1.5 pages)

  1. Cartes infographiques du Symposium Afrique de l'Ouest et du Centre

    International Development Research Centre (IDRC) Digital Library (Canada)

    fdieudonne

    VILLES SÛRES ET INCLUSIVES | AFRIQUE DE L'OUEST ET DU CENTRE. Spécificités de violence, d'exclusion, et de lutte contre la criminalité. République démocratique du Congo: Taux de natalité par femme, en moyenne 10 enfants, très élevé. Exclusion sociale exacerbée : des jeunes enfants accusés de sorcellerie.

  2. Une mesure différente du bien-être : l'indice du bonheur national ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    À la lumière de ces données, le Centre for Bhutan Studies publiera, en 2011, un indice du BNB quantitatif. Cette subvention permettra à l'OPHI d'assister le Centre dans la synthèse et l'analyse des résultats de l'enquête de 2010. L'objectif : assurer la validité et la reconnaissance internationale de l'indice du BNB de sorte ...

  3. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  4. Model Calibration in Option Pricing

    Directory of Open Access Journals (Sweden)

    Andre Loerx

    2012-04-01

    Full Text Available We consider calibration problems for models of pricing derivatives which occur in mathematical finance. We discuss various approaches such as using stochastic differential equations or partial differential equations for the modeling process. We discuss the development in the past literature and give an outlook into modern approaches of modelling. Furthermore, we address important numerical issues in the valuation of options and likewise the calibration of these models. This leads to interesting problems in optimization, where, e.g., the use of adjoint equations or the choice of the parametrization for the model parameters play an important role.

  5. Instrument Calibration and Certification Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R. Wesley [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-05-31

    The Amptec 640SL-2 is a 4-wire Kelvin failsafe resistance meter, designed to reliably use very low-test currents for its resistance measurements. The 640SL-1 is a 2-wire version, designed to support customers using the Reynolds Industries type 311 connector. For both versions, a passive (analog) dual function DC Milliameter/Voltmeter allows the user to verify the actual 640SL output current level and the open circuit voltage on the test leads. This procedure includes tests of essential performance parameters. Any malfunction noticed during calibration, whether specifically tested for or not, shall be corrected before calibration continues or is completed.

  6. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  7. Tank calibration; Arqueacao de tanques

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Ana [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    This work relates the analysis of the norms ISO (International Organization for Standardization) for calibration of vertical cylindrical tanks used in fiscal measurement, established on Joint Regulation no 1 of June 19, 2000 between the ANP (National Agency of Petroleum) and the INMETRO (National Institute of Metrology, Normalization and Industrial Quality). In this work a comparison between norms ISO and norms published by the API (American Petroleum Institute) and the IP (Institute of Petroleum) up to 2001 was made. It was concluded that norms ISO are wider than norms API, IP, and INMETRO methods in the calibration of vertical cylindrical tanks. (author)

  8. Maison du Peuple; Jean Prouvè

    DEFF Research Database (Denmark)

    Beim, Anne

    2017-01-01

    The chapter presents a deep analysis of Maison du Peuple, de Clichy in Paris by the French architect and manufacturer Jean Prouvè. The historical context of the original ideas behind the building and how and by which means it was constructed are being examined from a tectonic perspective....

  9. les cahiers du cread - Vol 101 (2012)

    African Journals Online (AJOL)

    Les importations subventionnees de genisses a haut potentiel laitier : Un echec du a l'absence de politique laitiere globale · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Hamida Kheffache, Slimane Bedrani ...

  10. The case of Cirque du Soleil Dralion

    African Journals Online (AJOL)

    Cirque entered this landscape not by competing with the traditional circus, but by redefining it altogether (Leslie ... Amidst the decline in traditional travelling circuses in South Africa, the popularity of sold-out Cirque du Soleil ... about their motives in order to devise effective marketing strategies. Swanson, Davis and Zhao ...

  11. Picholine marocaine clones X Picholine du Languedoc

    African Journals Online (AJOL)

    SERVER

    2007-12-17

    Dec 17, 2007 ... marocaine" cultivar and the "Picholine du Languedoc" cultivar, the descendants and their parents were analysed using 35 ... marocaine" is the most dominant cultivar; more than 98% ... this proportion, a χ2 test was calculated to test the null hypothesis. ... a lethal or semi-lethal locus (Bradshaw and Stettler,.

  12. récolte du melon

    African Journals Online (AJOL)

    SARAH

    30 sept. 2015 ... In vivo, 600 ppm of calcium silicate, calcium hydroxide and calcium oxide inhibited ... En 2013, la production du melon au Maroc a été .... Ca(OH)2, l'oxyde de calcium CaO, le sulfate de calcium ...... rot disease complex.

  13. PREDICTION DE LA CROISSANCE DU BANANIER PLANTAIN ...

    African Journals Online (AJOL)

    Hornik K., Stinchcombe M., White H., Auer P. 1994. Degree of approximation results of feedforward networks approximating unknown mapping et their derivatives. Neur. Net. Comp., 6 : 1262 - 1275. Jannoyer M. 1995. Déterminisme du nombre d'or- ganes reproducteurs d'une inflorescence de bananier (Musa acuminata, ...

  14. Neutron flux measurement and thermal power calibration of the IAN-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sarta Fuentes, Jose A.; Castiblanco Bohorquez, Luis A

    2008-10-29

    The IAN-R1 TRIGA reactor in Colombia was initially fueled with MTR-HEU enriched to 93% U-235, operated since 1965 at 10 kW, and was upgraded to 30 kW in 1980. General Atomics achieved in 1997 the conversion of HEU fuel to LEU fuel TRIGA type, and upgraded the reactor power to 100 kW. Since the IAN-R1 TRIGA reactor was in an extended shutdown during seven years, it was necessary to repeat some results of the commissioning test conducted in 1997. The thermal power calibration was carried out using the calorimetric method. The reactor was operated approximately at 20 kW during 3.5 hours, with manual power corrections since the automatic control system failed and with the forced refrigeration off. During the calorimetric experiment, the pool temperature was measured with a RTD which is installed near to the core. The dates were collected in intervals of 30 minutes. For establishing thermal power reactor, the water temperature versus the running were registered. For a calculated tank volume of 16 m{sup 3}, the tank constant calculated for the IAN-R1 TRIGA reactor is 0.0539 C/kW-hr. The reactor power determined was 19 kW. The core configuration is a rectangular grid plate that holds a combination of 4-rod and 3-rod clusters. The core contains 50 fuel rods with LEU fuel TRIGA (UZr H1.6) type enriched to 19.7%. The radial reflector consists of twenty graphite elements six of which are used for isotope production. The top an bottom reflectors are the cylindrical graphite end reflectors which are installed above and below of the active fuel section in each fuel rod. The spatial dependence of thermal neutron flux was measured axially in the 3-rod clusters 4C, 3D, 5E and in the 4F graphite element. The spatial distribution of the thermal neutron was determined using a self-powered detector and the absolute value of thermal neutron flux was determined by a gold activation detector. The (n, b- ) reaction is applied to determine the relative spatial distribution of thermal

  15. Binding thermodynamics of Diclofenac and Naproxen with human and bovine serum albumins: A calorimetric and spectroscopic study

    International Nuclear Information System (INIS)

    Bou-Abdallah, Fadi; Sprague, Samuel E.; Smith, Britannia M.; Giffune, Thomas R.

    2016-01-01

    phenomena were reported for Diclofenac and Naproxen binding to BSA but not to HSA. Fluorescence quenching data between Diclofenac and the two proteins suggest static collisions and the formation of ground-state protein-drug complexes. The DSC data corroborate the ITC findings and show multiple sequential unfolding events and a strong drug stabilization effect at high drug to protein ratios. Overall, the calorimetric and spectroscopic data provided insights into the nature of these protein-drugs interactions and might offer useful information in future drug discovery studies.

  16. Etude de la transition ferroelectrique-ferroelastique du KD2PO4 forme du front de phase en fonction du gradient thermique

    OpenAIRE

    Kvítek, Zdeněk

    2010-01-01

    Etude de la transition ferroelectrique-ferroelastique du KD2PO4 forme du front de phase en fonction du gradient thermique The thesis explores complex process of first order transition of KD2PO4 crystal from tetragonal phase to ferroelectric - ferroelastic orthorhombic phase and back at temperature 209 K. The experimental set up of nitrogeneous cryostat allowes temperature and temperature gradient variations during simultaneous three axes optical sample observations, dielectric measurements. T...

  17. Néotoponymie contestée à Potchefstroom / Tlokwe (Province du Nord-Ouest, Afrique du Sud

    Directory of Open Access Journals (Sweden)

    Myriam Houssay-Holzschuch

    2010-09-01

    Full Text Available Illustration 1 - Extrait du site de la municipalité de Potchefstroom / TlokweSource : http://www.potch.co.za/newsarchive/streetnames.htmlIllustration 2- Potchefstroom (Afrique du SudAuteur : Béatrice Obry-Guyot, début décembre 2007.Illustration 3 - Extrait du plan Google Map de PotchefstroomSource : Google Map.La question toponymique en Afrique du Sud sur la longue durée porte sur deux thèmes essentiels porteurs de controverses : le plurilinguisme et le marquage symbolique et mémoriel du te...

  18. Scalar Calibration of Vector Magnetometers

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Brauer, Peter; Primdahl, Fritz

    2000-01-01

    The calibration parameters of a vector magnetometer are estimated only by the use of a scalar reference magnetometer. The method presented in this paper differs from those previously reported in its linearized parametrization. This allows the determination of three offsets or signals in the absence...

  19. Uniformity calibration for ICT image

    International Nuclear Information System (INIS)

    Zeng Gang; Liu Li; Que Jiemin; Zhang Yingping; Yin Yin; Wang Yanfang; Yu Zhongqiang; Yan Yonglian

    2004-01-01

    The uniformity of ICT image is impaired by beam hardening and the inconsistency of detector units responses. The beam hardening and the nonlinearity of the detector's output have been analyzed. The correction factors are determined experimentally by the detector's responses with different absorption length. The artifacts in the CT image of a symmetrical aluminium cylinder have been eliminated after calibration. (author)

  20. Calibration of the Wedge Prism

    Science.gov (United States)

    Charles B. Briscoe

    1957-01-01

    Since the introduction of plotless cruising in this country by Grosenbaugh and the later suggestion of using a wedge prism as an angle gauge by Bruce this method of determining basal area has been widely adopted in the South. One of the factors contributing to the occasionally unsatisfactory results obtained is failure to calibrate the prism used. As noted by Bruce the...

  1. Etude des phenomenes dynamiques ultrarapides et des caracteristiques impulsionnelles d'emission terahertz du supraconducteur YBCO

    Science.gov (United States)

    Savard, Stephane

    Les premieres etudes d'antennes a base de supraconducteurs a haute temperature critique emettant une impulsion electromagnetique dont le contenu en frequence se situe dans le domaine terahertz remontent a 1996. Une antenne supraconductrice est formee d'un micro-pont d'une couche mince supraconductrice sur lequel un courant continu est applique. Un faisceau laser dans le visible est focalise sur le micro-pont et place le supraconducteur dans un etat hors-equilibre ou des paires sont brisees. Grace a la relaxation des quasiparticules en surplus et eventuellement de la reformation des paires supraconductrices, nous pouvons etudier la nature de la supraconductivite. L'analyse de la cinetique temporelle du champ electromagnetique emis par une telle antenne terahertz supraconductrice s'est averee utile pour decrire qualitativement les caracteristiques de celle-ci en fonction des parametres d'operation tels que le courant applique, la temperature et la puissance d'excitation. La comprehension de l'etat hors-equilibre est la cle pour comprendre le fonctionnement des antennes terahertz supraconductrices a haute temperature critique. Dans le but de comprendre ultimement cet etat hors-equilibre, nous avions besoin d'une methode et d'un modele pour extraire de facon plus systematique les proprietes intrinseques du materiau qui compose l'antenne terahertz a partir des caracteristiques d'emission de celle-ci. Nous avons developpe une procedure pour calibrer le spectrometre dans le domaine temporel en utilisant des antennes terahertz de GaAs bombarde aux protons H+ comme emetteur et detecteur. Une fois le montage calibre, nous y avons insere une antenne emettrice dipolaire de YBa 2Cu3O7-delta . Un modele avec des fonctions exponentielles de montee et de descente du signal est utilise pour lisser le spectre du champ electromagnetique de l'antenne de YBa 2Cu3O7-delta, ce qui nous permet d'extraire les proprietes intrinseques de ce dernier. Pour confirmer la validite du modele

  2. High Gain Antenna Calibration on Three Spacecraft

    Science.gov (United States)

    Hashmall, Joseph A.

    2011-01-01

    This paper describes the alignment calibration of spacecraft High Gain Antennas (HGAs) for three missions. For two of the missions (the Lunar Reconnaissance Orbiter and the Solar Dynamics Observatory) the calibration was performed on orbit. For the third mission (the Global Precipitation Measurement core satellite) ground simulation of the calibration was performed in a calibration feasibility study. These three satellites provide a range of calibration situations-Lunar orbit transmitting to a ground antenna for LRO, geosynchronous orbit transmitting to a ground antenna fer SDO, and low Earth orbit transmitting to TDRS satellites for GPM The calibration results depend strongly on the quality and quantity of calibration data. With insufficient data the calibration Junction may give erroneous solutions. Manual intervention in the calibration allowed reliable parameters to be generated for all three missions.

  3. Calorimetric analysis of photopolymerization

    International Nuclear Information System (INIS)

    Hoyle, C.E.

    1992-01-01

    This review is divided into several sections. The first section establishes the basis for measurement of the heat evolution during polymerization by focusing on the chemical chain process that results in the exothermic production of heat. The second section describes the types of photocalorimeters and the methods and instrumentation involved in exothermic measurements. Considerable attention is given to the use of the differential scanning calorimeter to record the exothermic curves generated by photopolymerization of monofunctional and multifunctional monomers. The final section presents a thorough coverage of the results obtained by a large number of research groups using photocalorimetric measurements to provide a more accurate description of polymerization processes. 120 refs., 51 figs., 14 tabs

  4. Calorimetric measuring systems

    DEFF Research Database (Denmark)

    Ritchie, Andrew Ewen; Pedersen, John Kim; Blaabjerg, Frede

    2004-01-01

    in the system. If the switching speed can be increased, improvements may be possible (e.g., current ripple in an electrical machine or physical size of passive components may be reduced). On the other hand, increased switching speed may cause additional losses in a power electronic system and increase...... the system cooling requirement. A common problem is that high-frequency phenomena like proximity effect, skin effect, hysteresis losses, and eddy current losses appear in the systems. These losses are very difficult to treat both theoretically and in practice. It is often difficult to measure the effect...

  5. Radiometric Calibration of Osmi Imagery Using Solar Calibration

    Directory of Open Access Journals (Sweden)

    Dong-Han Lee

    2000-12-01

    Full Text Available OSMI (Ocean Scanning Multi-Spectral Imager raw image data (Level 0 were acquired and radiometrically corrected. We have applied two methods, using solar & dark calibration data from OSMI sensor and comparing with the SeaWiFS data, to the radiometric correction of OSMI raw image data. First, we could get the values of the gain and the offset for each pixel and each band from comparing the solar & dark calibration data with the solar input radiance values, calculated from the transmittance, BRDF (Bidirectional Reflectance Distribution Function and the solar incidence angle (¥â,¥è of OSMI sensor. Applying this calibration data to OSMI raw image data, we got the two odd results, the lower value of the radiometric corrected image data than the expected value, and the Venetian Blind Effect in the radiometric corrected image data. Second, we could get the reasonable results from comparing OSMI raw image data with the SeaWiFS data, and get a new problem of OSMI sensor.

  6. SMAP RADAR Calibration and Validation

    Science.gov (United States)

    West, R. D.; Jaruwatanadilok, S.; Chaubel, M. J.; Spencer, M.; Chan, S. F.; Chen, C. W.; Fore, A.

    2015-12-01

    The Soil Moisture Active Passive (SMAP) mission launched on Jan 31, 2015. The mission employs L-band radar and radiometer measurements to estimate soil moisture with 4% volumetric accuracy at a resolution of 10 km, and freeze-thaw state at a resolution of 1-3 km. Immediately following launch, there was a three month instrument checkout period, followed by six months of level 1 (L1) calibration and validation. In this presentation, we will discuss the calibration and validation activities and results for the L1 radar data. Early SMAP radar data were used to check commanded timing parameters, and to work out issues in the low- and high-resolution radar processors. From April 3-13 the radar collected receive only mode data to conduct a survey of RFI sources. Analysis of the RFI environment led to a preferred operating frequency. The RFI survey data were also used to validate noise subtraction and scaling operations in the radar processors. Normal radar operations resumed on April 13. All radar data were examined closely for image quality and calibration issues which led to improvements in the radar data products for the beta release at the end of July. Radar data were used to determine and correct for small biases in the reported spacecraft attitude. Geo-location was validated against coastline positions and the known positions of corner reflectors. Residual errors at the time of the beta release are about 350 m. Intra-swath biases in the high-resolution backscatter images are reduced to less than 0.3 dB for all polarizations. Radiometric cross-calibration with Aquarius was performed using areas of the Amazon rain forest. Cross-calibration was also examined using ocean data from the low-resolution processor and comparing with the Aquarius wind model function. Using all a-priori calibration constants provided good results with co-polarized measurements matching to better than 1 dB, and cross-polarized measurements matching to about 1 dB in the beta release. During the

  7. Présentation du volume

    Directory of Open Access Journals (Sweden)

    Ana Zwitter Vitez

    2012-12-01

    Full Text Available Dans de nombreuses disciplines scientifiques, le discours parlé représente depuis quelques décennies un objet de recherche proéminent. Ce fait s’explique probablement par deux caractéristiques principales du discours parlé: la structure complexe de sa matérialité et les fonctions variées de différentes pratiques langagières. C’est pourquoi le présent numéro réunit les articles basés sur les approches actuelles du discours parlé et sur les pratiques langagières spécifiques. Le volume est introduit par deux articles interdisciplinaires: Peter Garrard et Ahmed Samrah présentent le domaine de la pathologie du langage en donnant une revue fouillée sur les approches actuelles de l’analyse linguistique lors de la détection de la maladie d’Alzheimer, tandis que Harry Hollien donne un aperçu structuré sur le domaine de la phonétique judiciaire destiné à dévoiler l’identité des locuteurs et de détecter la déception dans le discours parlé. Les analyses explorant l’acquisition du langage commencent par l’article de Katharina Zipser qui examine la progression de structures grammaticales en les mettant en comparaison avec la compétence des apprenants et continuent par l’étude de Meta Lah proposant une évaluation des documents audiovisuels proposés aux apprenants de langue étrangère. Vesna Požgaj Hadži, Damir Horga et Tatjana Balažic Bulc remettent en question la corrélation entre la compétence linguistique et la fluence linguistique auprès de locuteurs non-maternels et l'analyse de Gemma Santiago Alonso aborde l'acquisition de l'article défini dans le langage enfantin. Les articles suivants se réunissent autour du domaine de l'interprétation: Jana Zidar Forte présente une approche actuelle dans l'entrainement d'interprètes, Lea Burjan analyse les phénomènes issus de la pratique de l'interprétation juridique et Simona  Šumrada traite de la reformulation dans le discours de la traduction et de

  8. Automated Attitude Sensor Calibration: Progress and Plans

    Science.gov (United States)

    Sedlak, Joseph; Hashmall, Joseph

    2004-01-01

    This paper describes ongoing work a NASA/Goddard Space Flight Center to improve the quality of spacecraft attitude sensor calibration and reduce costs by automating parts of the calibration process. The new calibration software can autonomously preview data quality over a given time span, select a subset of the data for processing, perform the requested calibration, and output a report. This level of automation is currently being implemented for two specific applications: inertial reference unit (IRU) calibration and sensor alignment calibration. The IRU calibration utility makes use of a sequential version of the Davenport algorithm. This utility has been successfully tested with simulated and actual flight data. The alignment calibration is still in the early testing stage. Both utilities will be incorporated into the institutional attitude ground support system.

  9. Automated Calibration of Dosimeters for Diagnostic Radiology

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2015-01-01

    Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)

  10. Crop physiology calibration in the CLM

    Directory of Open Access Journals (Sweden)

    I. Bilionis

    2015-04-01

    scalable and adaptive scheme based on sequential Monte Carlo (SMC. The model showed significant improvement of crop productivity with the new calibrated parameters. We demonstrate that the calibrated parameters are applicable across alternative years and different sites.

  11. Calibration of alpha surface contamination monitor

    International Nuclear Information System (INIS)

    Freitas, I.S.M. de; Goncalez, O.L.

    1990-01-01

    In this work, the results, as well as the methodology, of the calibration of an alpha surface contamination monitor are presented. The calibration factors are obtained by least-squares fitting with effective variance. (author)

  12. Calibration curves for biological dosimetry

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M. . E-mail cgc@nuclear.inin.mx

    2004-01-01

    The generated information by the investigations in different laboratories of the world, included the ININ, in which settles down that certain class of chromosomal leisure it increases in function of the dose and radiation type, has given by result the obtaining of calibrated curves that are applied in the well-known technique as biological dosimetry. In this work is presented a summary of the work made in the laboratory that includes the calibrated curves for gamma radiation of 60 Cobalt and X rays of 250 k Vp, examples of presumed exposure to ionizing radiation, resolved by means of aberration analysis and the corresponding dose estimate through the equations of the respective curves and finally a comparison among the dose calculations in those people affected by the accident of Ciudad Juarez, carried out by the group of Oak Ridge, USA and those obtained in this laboratory. (Author)

  13. Astrid-2 EMMA Magnetic Calibration

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Brauer, Peter; Risbo, Torben

    1998-01-01

    The Swedish micro-satellite Astrid-2 contains a tri-axial fluxgate magnetometer with the sensor co-located with a Technical University of Denmark (DTU) star camera for absolute attitude, and extended about 0.9 m on a hinged boom. The magnetometer is part of the RIT EMMA electric and magnetic fields...... experiment built as a collaboration between the DTU, Department of Automation and the Department of Plasma Physics, The Alfvenlaboratory, Royal Institute of Technology (RIT), Stockholm. The final magnetic calibration of the Astrid-2 satellite was done at the Lovoe Magnetic Observatory under the Geological...... Survey of Sweden near Stockholm on the night of May 15.-16., 1997. The magnetic calibration and the intercalibration between the star camera and the magnetic sensor was performed by measuring the Earth's magnetic field and simultaneously observing the star sky with the camera. The rotation matrix between...

  14. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  15. DU-AGG pilot plant design study

    International Nuclear Information System (INIS)

    Lessing, P.A.; Gillman, H.

    1996-07-01

    The Idaho National Engineering Laboratory (INEL) is developing new methods to produce high-density aggregate (artificial rock) primarily consisting of depleted uranium oxide. The objective is to develop a low-cost method whereby uranium oxide powder (UO[sub 2], U[sub 3]O[sub ]8, or UO[sub 3]) can be processed to produce high-density aggregate pieces (DU-AGG) having physical properties suitable for disposal in low-level radioactive disposal facilities or for use as a component of high-density concrete used as shielding for radioactive materials. A commercial company, G-M Systems, conducted a design study for a manufacturing pilot plant to process DU-AGG. The results of that study are included and summarized in this report. Also explained are design considerations, equipment capacities, the equipment list, system operation, layout of equipment in the plant, cost estimates, and the proposed plan and schedule

  16. L’écologie du coupable.

    Directory of Open Access Journals (Sweden)

    André Ourednik

    2006-04-01

    Full Text Available « Denn dass der Mensch erlöst werde von der Rache  : das ist mir die Brücke zur höchsten Hoffnung und ein Regenbogen nach langen Unwettern. » 1 Nous l’aurions presque oublié, en fouillant parmi les fondations du rapport moral au monde de nos sociétés, nous trouverons encore bien en place deux piliers érigés au cours du processus de la chrétienté : celui de l’ empathie et celui de la culpabilité . Le premier semble offrir le seul appui plausible à notre vivre ...

  17. Satellite imager calibration and validation

    CSIR Research Space (South Africa)

    Vhengani, L

    2010-10-01

    Full Text Available and Validation Lufuno Vhengani*, Minette Lubbe, Derek Griffith and Meena Lysko Council for Scientific and Industrial Research, Defence Peace Safety and Security, Pretoria, South Africa E-mail: * lvhengani@csir.co.za Abstract: The success or failure... techniques specific to South Africa. 1. Introduction The success or failure of any earth observation mission depends on the quality of its data. To achieve optimum levels of reliability most sensors are calibrated pre-launch. However...

  18. Multidetector calibration for mass spectrometers

    International Nuclear Information System (INIS)

    Bayne, C.K.; Donohue, D.L.; Fiedler, R.

    1994-06-01

    The International Atomic Energy Agency's Safeguards Analytical Laboratory has performed calibration experiments to measure the different efficiencies among multi-Faraday detectors for a Finnigan-MAT 261 mass spectrometer. Two types of calibration experiments were performed: (1) peak-shift experiments and (2) peak-jump experiments. For peak-shift experiments, the ion intensities were measured for all isotopes of an element in different Faraday detectors. Repeated measurements were made by shifting the isotopes to various Faraday detectors. Two different peak-shifting schemes were used to measure plutonium (UK Pu5/92138) samples. For peak-jump experiments, ion intensities were measured in a reference Faraday detector for a single isotope and compared with those measured in the other Faraday detectors. Repeated measurements were made by switching back-and-forth between the reference Faraday detector and a selected Faraday detector. This switching procedure is repeated for all Faraday detectors. Peak-jump experiments were performed with replicate measurements of 239 Pu, 187 Re, and 238 U. Detector efficiency factors were estimated for both peak-jump and peak-shift experiments using a flexible calibration model to statistically analyze both types of multidetector calibration experiments. Calculated detector efficiency factors were shown to depend on both the material analyzed and the experimental conditions. A single detector efficiency factor is not recommended for each detector that would be used to correct routine sample analyses. An alternative three-run peak-shift sample analysis should be considered. A statistical analysis of the data from this peak-shift experiment can adjust the isotopic ratio estimates for detector differences due to each sample analysis

  19. Calibrating thermal behavior of electronics

    Science.gov (United States)

    Chainer, Timothy J.; Parida, Pritish R.; Schultz, Mark D.

    2016-05-31

    A method includes determining a relationship between indirect thermal data for a processor and a measured temperature associated with the processor, during a calibration process, obtaining the indirect thermal data for the processor during actual operation of the processor, and determining an actual significant temperature associated with the processor during the actual operation using the indirect thermal data for the processor during actual operation of the processor and the relationship.

  20. Calibration of optically trapped nanotools

    Energy Technology Data Exchange (ETDEWEB)

    Carberry, D M; Simpson, S H; Grieve, J A; Hanna, S; Miles, M J [H H Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Wang, Y; Schaefer, H; Steinhart, M [Institute for Chemistry, University of Osnabrueck, Osnabrueck (Germany); Bowman, R; Gibson, G M; Padgett, M J, E-mail: m.j.miles@bristol.ac.uk [SUPA, Department of Physics and Astronomy, University of Glasgow, Science Road, Glasgow G12 8QQ (United Kingdom)

    2010-04-30

    Holographically trapped nanotools can be used in a novel form of force microscopy. By measuring the displacement of the tool in the optical traps, the contact force experienced by the probe can be inferred. In the following paper we experimentally demonstrate the calibration of such a device and show that its behaviour is independent of small changes in the relative position of the optical traps. Furthermore, we explore more general aspects of the thermal motion of the tool.

  1. Optimal Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Kroon, I. B.; Faber, Michael Havbro

    1994-01-01

    Calibration of partial safety factors is considered in general, including classes of structures where no code exists beforehand. The partial safety factors are determined such that the difference between the reliability for the different structures in the class considered and a target reliability...... level is minimized. Code calibration on a decision theoretical basis is also considered and it is shown how target reliability indices can be calibrated. Results from code calibration for rubble mound breakwater designs are shown....

  2. Technical guidelines for personnel dosimetry calibrations

    International Nuclear Information System (INIS)

    Roberson, P.L.; Fox, R.A.; Hadley, R.T.; Holbrook, K.L.; Hooker, C.D.; McDonald, J.C.

    1983-01-01

    A base of technical information has been acquire and used to evaluate the calibration, design, and performance of selected personnel systems in use at Department of Energy (DOE) facilites. A technical document was prepared to guide DOE and DOE contractors in selecting and evaluating personnel dosimetry systems and calibration. A parallel effort was initiated to intercompare the adiological calibrations standards used to calibrate DOE personnel dosimeters

  3. Calibration of ALIBAVA readout system

    Energy Technology Data Exchange (ETDEWEB)

    Trofymov, Artur [DESY, Hamburg (Germany); Collaboration: ATLAS experiment-Collaboration

    2015-07-01

    The High Luminosity Large Hadron Collider (LH-LHC) is the upgrade of the LHC that foreseen to increase the instantaneous luminosity by a factor ten with a total integrated luminosity of 3000 fb{sup -1}. The ATLAS experiment will need to build a new tracker to operate in the new severe LH-LHC conditions (increasing detector granularity to cope with much higher channel occupancy, designing radiation-hard sensors and electronics to cope with radiation damage). Charge collection efficiency (CCE) of silicon strip sensors for the new ATLAS tracker can be done with ALIBAVA analog readout system (analog system gives more information about signal from all strips than digital). In this work the preliminary results of ALIBAVA calibration using two different methods (with ''source data'' and ''calibration data'') are presented. Calibration constant obtained by these methods is necessary for knowing collected charge on the silicon strip sensors and for having the ability to compare it with measurements done at the test beam.

  4. Calibration of RB reactor power

    International Nuclear Information System (INIS)

    Sotic, O.; Markovic, H.; Ninkovic, M.; Strugar, P.; Dimitrijevic, Z.; Takac, S.; Stefanovic, D.; Kocic, A.; Vranic, S.

    1976-09-01

    The first and only calibration of RB reactor power was done in 1962, and the obtained calibration ratio was used irrespective of the lattice pitch and core configuration. Since the RB reactor is being prepared for operation at higher power levels it was indispensable to reexamine the calibration ratio, estimate its dependence on the lattice pitch, critical level of heavy water and thickness of the side reflector. It was necessary to verify the reliability of control and dosimetry instruments, and establish neutron and gamma dose dependence on reactor power. Two series of experiments were done in June 1976. First series was devoted to tests of control and dosimetry instrumentation and measurements of radiation in the RB reactor building dependent on reactor power. Second series covered measurement of thermal and epithermal neuron fluxes in the reactor core and calculation of reactor power. Four different reactor cores were chosen for these experiments. Reactor pitches were 8, 8√2, and 16 cm with 40, 52 and 82 fuel channels containing 2% enriched fuel. Obtained results and analysis of these results are presented in this document with conclusions related to reactor safe operation

  5. Model Calibration in Watershed Hydrology

    Science.gov (United States)

    Yilmaz, Koray K.; Vrugt, Jasper A.; Gupta, Hoshin V.; Sorooshian, Soroosh

    2009-01-01

    Hydrologic models use relatively simple mathematical equations to conceptualize and aggregate the complex, spatially distributed, and highly interrelated water, energy, and vegetation processes in a watershed. A consequence of process aggregation is that the model parameters often do not represent directly measurable entities and must, therefore, be estimated using measurements of the system inputs and outputs. During this process, known as model calibration, the parameters are adjusted so that the behavior of the model approximates, as closely and consistently as possible, the observed response of the hydrologic system over some historical period of time. This Chapter reviews the current state-of-the-art of model calibration in watershed hydrology with special emphasis on our own contributions in the last few decades. We discuss the historical background that has led to current perspectives, and review different approaches for manual and automatic single- and multi-objective parameter estimation. In particular, we highlight the recent developments in the calibration of distributed hydrologic models using parameter dimensionality reduction sampling, parameter regularization and parallel computing.

  6. DuPont Chemical Vapor Technical Report

    International Nuclear Information System (INIS)

    MOORE, T.L.

    2003-01-01

    DuPont Safety Resources was tasked with reviewing the current chemical vapor control practices and providing preventive recommendations on best commercial techniques to control worker exposures. The increased focus of the tank closure project to meet the 2024 Tri-Party Agreement (TPA) milestones has surfaced concerns among some CH2MHill employees and other interested parties. CH2MHill is committed to providing a safe working environment for employees and desires to safely manage the tank farm operations using appropriate control measures. To address worker concerns, CH2MHill has chartered a ''Chemical Vapors Project'' to integrate the activities of multiple CH2MHill project teams, and solicit the expertise of external resources, including an independent Industrial Hygiene expert panel, a communications consultant, and DuPont Safety Resources. Over a three-month time period, DuPont worked with CH2MHill ESH and Q, Industrial Hygiene, Engineering, and the independent expert panel to perform the assessment. The process included overview presentations, formal interviews, informal discussions, documentation review, and literature review. DuPont Safety Resources concluded that it is highly unlikely that workers in the tank farms are exposed to chemicals above established standards. Additionally, the conventional and radiological chemistry is understood, the inherent chemical hazards are known, and the risk associated with chemical vapor exposure is properly managed. The assessment highlighted management's commitment to addressing chemical vapor hazards and controlling the associated risks. Additionally, we found the Industrial Hygiene staff to be technically competent and well motivated. The tank characterization data resides in a comprehensive database containing the tank chemical compositions and relevant airborne concentrations

  7. Autour du paradigme d’écotourisme

    Directory of Open Access Journals (Sweden)

    Anne-Laure Transler

    2008-02-01

    Full Text Available L’écotourisme ouvre un cadre conceptuel original qui permet d’envisager des démarches renouvelées de développement à partir des revenus issus de consommations touristiques mieux réfléchies et organisées, susceptibles de soutenir des initiatives de développement local s’inscrivant dans un projet global de développement durable. Variante douce du tourisme, loin du tourisme de masse, le champ de l’écotourisme s’étend aux confins du tourisme de nature, du tourisme culturel et des pratiques scientifiques et sportives de plein air. Une définition de l’écotourisme peut être proposée à partir des six points suivants : 1/ nature et culture, 2/ le bien-être des sociétés hôtes, 3/ des touristes responsables, 4/ la participation des sociétés hôtes, 5/ la durabilité, 6/ l’art de la rencontre.Ecotourism provides an original conceptual framework that enables approaches to development that are better able to provide a more equitable distribution of income, as well as better organized and thought through initiatives which are more likely to promote a holistic sustainable local development. With somewhat less negative impact than normal tourism, considerably less that mass tourism, ecotourism can encompass nature tourism, cultural tourism, scientific exploration, and even outdoor sports... A definition of ecotourism should take into account the following six points: 1/ nature and culture, 2/ the welfare of the host community, tourists acting responsibly, 3/ participation by the local community, 5 / sustainability , 6/ promotion of cultural exchanges

  8. Le cas du Brésil

    International Development Research Centre (IDRC) Digital Library (Canada)

    pwust

    important volet des activités de coopération du Brésil dans les pays en développement, ...... attention à l'Amérique latine ou aux Caraïbes, malgré la priorité accordée à .... prudente et sélective face aux opérations triangulaires, afin d'éviter la ...

  9. Fès, la cybercapitale du Maroc

    International Development Research Centre (IDRC) Digital Library (Canada)

    Fès, la cybercapitale du Maroc. La ville de Fès est devenue un modèle primé en matière de mise en œuvre efficace des technologies de l'information et de la communication (TIC) dans les services publics d'un pays africain. ès, au Maroc. Dans une pièce renfermée datant des années 1950, des centaines de documents.

  10. Inventaire des champignons ectomycorhiziens du Maroc

    African Journals Online (AJOL)

    SARAH

    31 juil. 2014 ... RÉSUMÉ. Objectif : Le travail présenté ici a pour objectif de dresser, à partir de la bibliographie, l'inventaire des espèces ectomycorhiziennes du Maroc. Méthodologie et résultats : Les données sur les champignons, recueillies à partir de différents travaux publiés nous ont permis de réaliser un premier ...

  11. Les sens du musée

    Directory of Open Access Journals (Sweden)

    Laurent Grison

    1999-09-01

    Full Text Available Cet article, fondé sur l'exemple de la National Gallery de Londres, porte sur l'intégration dans le cadre urbain, l'aménagement et les dynamiques spatiales du lieu muséal. Sur le même thème, nous relatons un exercice réalisé avec des lycéens.

  12. Technostress et autres revers du travail nomade

    NARCIS (Netherlands)

    Popma, J.

    2013-01-01

    L'Internet et l'utilisation des ordinateurs portables, des téléphones mobiles et des tablettes ont accru l'importance du « travail nomade». Ce type de travail, sans contrainte de lieu ni de temps, peut entraîner, d’après ce working paper, une plus grande autonomie et une plus grande flexibilité pour

  13. KYSTE DERMOÏDE DU PLANCHER BUCCAL

    African Journals Online (AJOL)

    18 juin 2007 ... molle, indolore bien limitée, sessile ou pédiculée, lisse avec un aspect jaune caractéristique[10]. La palpation bidigitale, l'échographie associée à une ponc- tion cytologique, le scanner et au mieux l'IRM sont essen- tiels pour l'orientation étiologique devant toute lésion du plancher buccal [8]. En effet, l'IRM ...

  14. Administration des subventions du CRDI aux institutions :

    International Development Research Centre (IDRC) Digital Library (Canada)

    IDRC CRDI

    Comment puis-je réviser le budget de mon projet ? Le CRDI couvre-t-il les dépenses engagées en sus du montant de la subvention ? De quelle façon le CRDI transmet-il les fonds ? Mon institution doit-elle déposer les fonds reçus pour le projet dans un compte bancaire distinct ? Combien de temps faut-il au CRDI pour ...

  15. PersPectives du Programme acca

    International Development Research Centre (IDRC) Digital Library (Canada)

    à acca@crdi.ca. À propos du programme ACCA. Lancé en 2006, le programme Adaptation aux changements ... Nous pourrions y ajouter, par soucis d'équilibre, les « connus inconnus », c'est- à-dire les connaissances que nous ne ...... marocain m'a déjà dit ceci : « Je comprends vos préoccupations, mais mes questions ...

  16. Les Gammaridae (Crustaces, Amphipodes) du Massif Central

    NARCIS (Netherlands)

    Goedmakers, Annemarie

    1974-01-01

    Une prospection systématique des eaux courantes du Massif Central a permis de reconnaître le nombre d’espèces des Gammaridés présentes dans cette région. On a trouvé les espèces suivantes: Gammarus pulex (Linnaeus, 1758), G. fossarum Koch, 1835, et G. ibericus Margalef, 1951. G. ibericus, espèce

  17. L’écriture du temps dans Robinson Crusoe

    OpenAIRE

    Bulckaen, Denise

    2018-01-01

    “Le récit est une séquence deux fois temporelle... il y a le temps de la chose-racontée et le temps du récit (temps du signifié et temps du signifiant)”. Cette citation se trouve au début du chapitre que Genette consacre à “Ordre” dans Figures III. Elle s'applique à de nombreux romans, mais elle est particulièrement intéressante quand on considère le roman de forme autobiographique. Le décalage entre “le temps du signifié” et “le temps du signifiant” est plus ou moins grand selon les romans. ...

  18. Enfants du soleil histoire de nos origines

    CERN Document Server

    Brahic, André

    1999-01-01

    D'où venons-nous ? Comment le Soleil et la Terre sont-ils apparus ? Nous avons enfin atteint le moment où la science peut apporter des réponses de plus en plus précises, de plus en plus étonnantes. La Nature a décidément plus d'imagination que les hommes ! Depuis l'exploration spatiale, nous en avons plus appris sur notre système solaire et son origine en une génération qu'en quarante siècles. Là où l'on attendait l'uniformité, on a trouvé la plus grande diversité. André Brahic, qui a découvert les anneaux de Neptune, nous présente les multiples facettes du système solaire et nous raconte quatre milliards et demi d'années de son histoire. Les planètes sont les soeurs du Soleil. Nous sommes les enfants du temps et des étoiles. Sommes-nous seuls dans l'Univers ? Les astronomes commencent à apercevoir d'autres planètes autour de quelques soleils proches, Ils espèrent bientôt trouver d'autres Terres...

  19. Ksenia Pimenova, Les sources de savoirs. Le renouveau du bouddhisme et du chamanisme chez les Touvas de la Sibérie du Sud

    OpenAIRE

    Pimenova, Ksenia

    2013-01-01

    Cette thèse présente une étude comparative du « renouveau » post-soviétique du chamanisme et du bouddhisme tibétain (école Guélougpa) chez les Touvas, un des peuples autochtones de la Sibérie du Sud (Russie). Ce phénomène a lieu après des décennies de politique antireligieuse (dès la fin des années 1920 jusqu’aux années 1980) ayant abouti à la destruction de la communauté bouddhique et à la marginalisation du chamanisme. Nous analysons le chamanisme et le bouddhisme post-soviétiques comme deu...

  20. Optimal, Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2002-01-01

    Reliability based code calibration is considered in this paper. It is described how the results of FORM based reliability analysis may be related to the partial safety factors and characteristic values. The code calibration problem is presented in a decision theoretical form and it is discussed how...... of reliability based code calibration of LRFD based design codes....

  1. Code Calibration as a Decision Problem

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Kroon, I. B.; Faber, Michael Havbro

    1993-01-01

    Calibration of partial coefficients for a class of structures where no code exists is considered. The partial coefficients are determined such that the difference between the reliability for the different structures in the class considered and a target reliability level is minimized. Code...... calibration on a decision theoretical basis is discussed. Results from code calibration for rubble mound breakwater designs are shown....

  2. 40 CFR 1065.310 - Torque calibration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Torque calibration. 1065.310 Section... Conditions § 1065.310 Torque calibration. (a) Scope and frequency. Calibrate all torque-measurement systems including dynamometer torque measurement transducers and systems upon initial installation and after major...

  3. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  4. Calibration and simulation of Heston model

    Directory of Open Access Journals (Sweden)

    Mrázek Milan

    2017-05-01

    Full Text Available We calibrate Heston stochastic volatility model to real market data using several optimization techniques. We compare both global and local optimizers for different weights showing remarkable differences even for data (DAX options from two consecutive days. We provide a novel calibration procedure that incorporates the usage of approximation formula and outperforms significantly other existing calibration methods.

  5. Nuclear radiation moisture gauge calibration standard

    International Nuclear Information System (INIS)

    1977-01-01

    A hydrophobic standard for calibrating nuclear radiation moisture gauges is described. Each standard has physical characteristics and dimensions effective for representing to a nuclear gauge undergoing calibration, an infinite mass of homogeneous hydrogen content. Calibration standards are discussed which are suitable for use with surface gauges and with depth gauges. (C.F.)

  6. Calorimetric Study of Phase Transitions Involving Twist-Grain-Boundary TGB{A} and TGB{C} Phases

    Science.gov (United States)

    Navailles, L.; Garland, C. W.; Nguyen, H. T.

    1996-09-01

    High-resolution calorimetry has been used to determine the heat capacity and latent heat associated with phase transitions in the homologous series of chiral liquid crystals nF_2BTFO_1M_7 [ 3-fluoro-4(1-methylheptyloxy)4'-(4''-alkoxy-2'', 3''-difluorobenzoyloxy)tolane] . These compounds exhibit smectic-C^* (SmC^*), twist-grain-boundary (TGBA for n=10, TGBC for n=11, 12) and cholesteric (N^*) phases. All the phase transitions are first order with small to moderate latent heats. There is a large rounded excess heat capacity peak in the N^* phase that is consistent with the predicted appearance of short-range TGB order (chiral line liquid character). This is analogous to the development of an Abrikosov flux vortex liquid in type-II superconductors. Both the n=11 and 12 homologs exhibit two closely spaced transitions in the region where a single TGBC - N^* transition was expected. This suggests the existence of two thermodynamically distinct TGBC phases. Des exprériences de calorimétrie haute résolution ont été réalisées pour déterminer les chaleurs spécifiques et les chaleurs latentes associées aux transitions de phase des homologues de la série crystal liquide nF_2BTFO_1M_7: 3-fluoro-4[1-methyl-heptyloxy]4'-(4''-alcoxy-2'', 3''-difluorobenzoyloxy)tolanes. Ces produits présentent la phase smectique C^* (SmC^*), les phases à torsion par joint de grain (TGBA pour n=10 et TGBC pour n=11, 12) et la phase cholestérique (N^*). Toutes les transitions de phase sont du premier ordre. La chaleur latente associée à ces transitions est faibles ou modérée. Nous observons, dans la phase N^*, un grand pic arrondi qui est en accord avec les prédictions de l'apparition d'un ordre TGB à courte distance (liquide de ligne de dislocation). Ce phénomène est l'analogue du liquide de vortex dans les supraconducteurs de type II. Les composés n=11 et 12 présentent, dans la région où nous attendions une transition TGBC - N^* unique, deux transitions sur un très faible

  7. Ved du, hvad der er i dine varer, når du handler?

    DEFF Research Database (Denmark)

    Phillip, Anja; Smith, Viktor

    2016-01-01

    I supermarkedet på vej hjem køber du ind til madpakken. Ved kølemontren med pålæg ser du en pakke Gårdlykke Hønsesalat. ... Måske vælger du den uden at tænke nærmere over hvorfor, eller fordi emballagen og navnet får hønsesalaten til at fremstå lokal, hjemmelavet eller økologisk. ... Alt dette ba...... bakkes op af resultaterne fra årelang forskning på CBS, hvor universitetets forskergruppe Fair-Speak har undersøgt emballagernes måde at påvirke forbrugerne til at købe produktet....

  8. 98 Etude Comparative du Systeme Phonematique et Tonal des ...

    African Journals Online (AJOL)

    98. Etude Comparative du Systeme Phonematique et Tonal des. Deux Parlers: Le Yoruba du Nigeria et L'itsa Parle en. Republique du Benin. Ajani Akinwumi Lateef et Ayuba G. Ajibabi http://dx.doi./org/10.4314/ujah.v18i3.5. Résume. En ce début de l'époque ou la mondialisation et la coexistence des peuples dans le ...

  9. Carcinome du tube collecteur de Bellini: une nouvelle observation ...

    African Journals Online (AJOL)

    Le carcinome du tube collecteur de Bellini est un type très rare des carcinomes à cellules rénales (CCR), sa fréquence est inférieure à 1%. Il dérive de la partie distale du néphron, plus précisément du tube collecteur. Ses aspects morphologiques sont extrêmement variables, rendant son diagnostic difficile. Nous rapportons ...

  10. Bourse du CRDI aux chercheurs candidats au doctorat 2018 | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Carrières · Communiquez avec nous · Plan du site. Abonnez-vous à notre bulletin pour recevoir les nouvelles du CRDI chaque mois. Abonnez-vous · Droits d'auteur · Éthique de la recherche · Politique de libre accès · Politique de confidentialité · Transparence · Utilisation du site Web. Suivez-nous; Facebook · Twitter ...

  11. Incorporation du coprah et des cuticules de cacao et d'arachide ...

    African Journals Online (AJOL)

    Incorporation du coprah et des cuticules de cacao et d'arachide dans l'aliment du ( tilapia du nil( ( Oreohromis niloticus , linné, 1758) eleve en etang : Effet sur la croissance et la composition biochimique.

  12. Acoustic calibration apparatus for calibrating plethysmographic acoustic pressure sensors

    Science.gov (United States)

    Zuckerwar, Allan J. (Inventor); Davis, David C. (Inventor)

    1995-01-01

    An apparatus for calibrating an acoustic sensor is described. The apparatus includes a transmission material having an acoustic impedance approximately matching the acoustic impedance of the actual acoustic medium existing when the acoustic sensor is applied in actual in-service conditions. An elastic container holds the transmission material. A first sensor is coupled to the container at a first location on the container and a second sensor coupled to the container at a second location on the container, the second location being different from the first location. A sound producing device is coupled to the container and transmits acoustic signals inside the container.

  13. Matere z motnjami v duševnem razvoju

    OpenAIRE

    Kolarič, Sandra

    2015-01-01

    S pregledom tuje literature in že opravljenih raziskav v tujini smo v teoretičnem delu magistrske naloge zajeli značilnosti mater z motnjami v duševnem razvoju, dejavnike, ki vplivajo na uspešnost opravljanja materinske vloge, ter pravice oseb z motnjami v duševnem razvoju do starševstva, v povezavi z zakonodajo na slovenskem. Navedli smo vzroke za omejevanje reprodukcije pri ženskah z motnjami v duševnem razvoju in problematiko odvzema skrbništva materam z motnjami v duševnem razvoju nad otr...

  14. Autonomie du groupe restreint et performance

    Directory of Open Access Journals (Sweden)

    Elke Nissen

    2005-09-01

    Full Text Available Un groupe est autonome lorsqu'il prend lui-même en charge sa gestion (Abric, 1996 et lorsque celle-ci fonctionne bien. L'autonomie du groupe restreint est une caractéristique revendiquée dans le cadre actuel de l'expansion de dispositifs collaboratifs à distance entre apprenants. La question qui se pose alors est de savoir si un groupe restreint autonome est plus performant qu'un groupe moins autonome. L'autonomie d'un groupe d'apprentissage en ligne est-elle en relation avec la qualité de la réalisation de la tâche ? Est-elle en relation avec les progrès réalisés par les membres du groupe ? Dans le cadre de notre étude expérimentale, menée dans deux dispositifs pédagogiques différents (l'environnement d'apprentissage Babbelnet et une formation sur la plate-forme Acolad, des étudiants ont réalisé en groupes restreints, avec l'accompagnement d'un tuteur, une tâche de type actionnel – en l'occurrence une rédaction en langue étrangère (allemand ou anglais. Pour ce faire, ils disposaient d'aides méthodologiques et linguistiques dans l'environnement pédagogique en ligne. Ils ont interagi par le biais d'Internet au moyen de différents outils de communication. Une analyse de l'interaction qui a eu lieu dans chaque groupe, l'évaluation des rédactions réalisées conjointement, deux tests réalisés respectivement avant et après la phase de travail en groupe ainsi qu'un formulaire auto-administré nous permettent de mettre en lien l'autonomie des groupes, d'une part, et leur performance, voire leur apprentissage, d'autre part. Au vu de cette étude, il apparaît que l'autonomie du groupe n'a pas d'influence directe sur l'apprentissage des groupes restreints. En revanche, un rapport est visible entre l'appréciation du fonctionnement du groupe par ses membres et l'évolution de la performance des groupes.

  15. EQUILIBRE GLYCEMIQUE ET COMPLICATIONS MACROANGIOPATHIQUES DU DIABETE

    Directory of Open Access Journals (Sweden)

    Lyse BORDIER

    2017-05-01

    Full Text Available La question de l’efficacité d’un équilibre glycémique optimal dans la prévention des complications macroangiopathiques du diabète a fait l’objet d’une récente polémique. Si les faits sont clairs pour la microangiopathie notamment au cours du diabète de type 1, ils paraissent moins certains pour les complications cardiovasculaires du diabète de type 2. Cette constatation vient de l’intrication des autres facteurs de risque cardiovasculaires qui sont très fréquents chez ces patients. Cependant, les études de suivi sur une longue durée s’inscrivent en faveur de l’intérêt d’un bon équilibre glycémique sur les complications macroangiopathiques. Les résultats négatifs sur la mortalité de l’étude ACCORD et les inquiétudes concernant la rosiglitazone ont conduit à la mise en place d’études sur la sécurité d’utilisation des nouvelles molécules. Tous ces travaux ont abouti à la démonstration de l’absence de risque des iDPP-4 et de l’effet très positif de certaines molécules de la classe des analogues du GLP-1 et des iSGLT2.Il reste à espérer que la récente mise au point de l’Académie de Médecine soulignant que les complications du diabète de type 2 exigent une prévention multifactorielle qui passe obligatoirement par un contrôle optimisé de l'équilibre glycémique mette fin à une polémique inutile et dangereuse pour nos malades.

  16. Visite du Conseil des gouverneurs du CRDI en Afrique de l'Est ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    17 oct. 2017 ... La délégation dans la communauté La délégation à l'école féminine. La délégation avec les membres du Women's Group. Durant la visite, Jean Lebel et Molapo Qhobela, directeur général de la Fondation nationale de la recherche de l'Afrique du Sud, ont annoncé les projets retenus au Kenya et en ...

  17. Calorimetric, FTIR and 1H NMR measurements in combination with DFT calculations for monitoring solid-state changes of dynamics of sibutramine hydrochloride.

    Science.gov (United States)

    Pajzderska, Aleksandra; Chudoba, Dorota M; Mielcarek, Jadwiga; Wąsicki, Jan

    2012-10-01

    Two forms of sibutramine hydrochloride, monohydrate and anhydrous, have been investigated by calorimetric methods, Fourier transform infrared (FTIR) absorption and (1) H nuclear magnetic resonance (NMR) measurements as well as by density functional theory (DFT) of vibrational frequencies and infrared intensities, calculations of steric hindrances and Monte Carlo simulations. The results of FTIR spectra combined with DFT calculations permitted identification of the bands corresponding to the dynamics and vibrations of water molecules. NMR study and Monte Carlo simulations revealed the occurrence of reorientation jumps of the methyl groups in sibutramine cation and also revealed that the reorientation of isopropyl group is possible only in sibutramine monohydrate hydrochloride. The hydration of sibutramine hydrochloride causes a change in the conformation of sibutramine cation. Copyright © 2012 Wiley-Liss, Inc.

  18. Calibration of nuclear medicine gamma counters

    International Nuclear Information System (INIS)

    Orlic, M.; Spasic-Jokic, V.; Jovanovic, M.; Vranjes, S. . E-mail address of corresponding author: morlic@vin.bg.ac.yu; Orlic, M.)

    2005-01-01

    In this paper the practical problem of nuclear medicine gamma counters calibration has been solved by using dose calibrators CRC-15R with standard error ±5%. The samples from technetium generators have been measured both by dose calibrators CRC-15R and gamma counter ICN Gamma 3.33 taking into account decay correction. Only the linear part of the curve has practical meaning. The advantage of this procedure satisfies the requirements from international standards: the calibration of sources used for medical exposure be traceable to a standard dosimetry laboratory and radiopharmaceuticals for nuclear medicine procedures be calibrated in terms of activity of the radiopharmaceutical to be administered. (author)

  19. Cross-calibration of interferometric SAR data

    DEFF Research Database (Denmark)

    Dall, Jørgen

    2003-01-01

    Generation of digital elevation models from interferometric synthetic aperture radar (SAR) data is a well established technique. Achieving a high geometric fidelity calls for a calibration accounting for inaccurate navigation data and system parameters as well as system imperfections. Fully...... automated calibration techniques are preferable, especially for operational mapping. The author presents one such technique, called cross-calibration. Though developed for single-pass interferometry, it may be applicable to multi-pass interferometry, too. Cross-calibration requires stability during mapping...... ground control point is often needed. The paper presents the principles and mathematics of the cross-calibration technique and illustrates its successful application to EMISAR data....

  20. Multiple-Objective Stepwise Calibration Using Luca

    Science.gov (United States)

    Hay, Lauren E.; Umemoto, Makiko

    2007-01-01

    This report documents Luca (Let us calibrate), a multiple-objective, stepwise, automated procedure for hydrologic model calibration and the associated graphical user interface (GUI). Luca is a wizard-style user-friendly GUI that provides an easy systematic way of building and executing a calibration procedure. The calibration procedure uses the Shuffled Complex Evolution global search algorithm to calibrate any model compiled with the U.S. Geological Survey's Modular Modeling System. This process assures that intermediate and final states of the model are simulated consistently with measured values.