WorldWideScience

Sample records for calcutta cyclotron

  1. Calcutta

    Science.gov (United States)

    2001-01-01

    The city of Calcutta appears in this 24 by 34 km (15 by 21 mile) sub-scene, acquired March 29, 2000. In 1690 the British East India Company founded Calcutta as a trading post on the marshy east bank of the Hugli River. Chosen for its easily defensible location and its access to the Bay of Bengal, the site developed into an important trading port. In 1773 Calcutta was made the capital of British India. As merchants and workers from all over the Indian subcontinent flocked to the city, British interests prospered, and British colonizers built mansions and palaces on land reclaimed from the marshes and swampland. In 1912, however, Calcutta lost its position as the colonial capital to Delhi. The end of British rule in India in 1947 cut off many of Calcutta's sources of trade and brought a deluge of immigrants to the city. The Bangladesh war in 1971 exacerbated the influx of refugees. Today this vibrant city has a population of over 5 million, and continues to sprawl to the north and south from the central grid of its old European section. This image was acquired on June 23, 2002, covers an area of 33 x 27 km, and is located at 22.6 degrees north latitude and 88.3 degrees east longitude. The U.S. science team is located at NASA's Jet Propulsion Laboratory, Pasadena, Calif. The Terra mission is part of NASA's Science Mission Directorate. 1995-1997 Microsoft Corporation. All rights reserved.

  2. Contesting Calcutta Canons

    DEFF Research Database (Denmark)

    Roy, Mallarika Sinha

    2009-01-01

    in different districts of West Bengal and several provinces of India. Even though it has been one of the well-studied political and social events in postcolonial West Bengal, the gender dimension, particularly the history of women's participation, remains neglected in the historiography of the movement....... A critical review from the point of view of gender requires contextualisation of gender relations according to class, ethnicity, spatial locations, and cultural environments of men and women Naxalites. Through a discussion of the centrality of Calcutta - the metropolitan centre - in the dominant memory...

  3. Universal immunization in urban areas: Calcutta's success story.

    Science.gov (United States)

    Chaudhuri, E R

    1990-01-01

    The Central Government of Calcutta, India aimed to immunize 85% (85,262) of the city's 12 month old infants against polio, diphtheria, measles, tuberculosis, pertussis and tetanus. The Universal Immunization Program (UIP) achieved this target 3 months earlier than intended. In fact, at the end of December 1990, it achieved 110.6% for DPT3, 142.16% for OPV3, 151.96% for BCG, and 97% for measles. UIP was able to surpass its targets by emphasizing team work. Government, the private sector, UNICEF, and the voluntary sector made up the Apex Coordination Committee on Immunization headed up by the mayor. The committee drafted an action plan which included routine immunization sessions on a fixed day and intensive immunization drives. Further the involved organizations pooled together cold chain equipment. In addition, the District Family Welfare Bureau was the distribution center for vaccines, syringes, immunization cards, report formats, vaccine carriers, and ice packs. Health workers administered immunizations from about 300 centers generally on Wednesday, National Immunization Day. Intensive immunization drives focused on measles immunizations. UIP leaders encouraged all center to routinely record coverage and submit monthly progress reports to the District Family Welfare Bureau. The Calcutta Municipal Corporation coordinated promotion activities and social mobilization efforts. Promotion included radio and TV announcements, newspaper advertisements, cinema slides, billboards, and posters. The original UIP plan to use professional communicators to mobilize communities was ineffective, so nongovernmental organizations entered the slums to encourage people to encourage their neighbors to immunize their children. Further Islamic, Protestant, and Catholic leaders encouraged the faithful to immunize their children. A UNICEF officer noted that this success must be sustained, however.

  4. Hydrogeological investigation of ground water arsenic contamination in south Calcutta.

    Science.gov (United States)

    Chatterjee, A; Mukherjee, A

    1999-01-26

    Typical clinical symptoms of acute arsenic poisoning have been detected in 1000 residents near a factory in P.N. Mitra Lane, Behala, South Calcutta, located in a thickly populated area manufacturing copper acetoarsenite (Paris-Green) an arsenical pesticide for the past 25 years. Soil around the effluent dumping point of the factory was exceptionally contaminated, with arsenic, copper and chromium concentrations of 20,100-35,500 mg kg-1, 33,900-51,100 mg kg-1 and 5300-5510 mg kg-1. Arsenic and copper concentrations in bore-hole soils collected up to a depth of 24.4 m at the effluent dumping point, decreased with depth. Arsenous acid, arsenic acid, methylarsonic acid (MA) and dimethylarsinic acid (DMA) were detected in bore-hole soils up to a depth of 1.37 m, after which only inorganic arsenical compounds were present. A positive correlation was established between arsenic and copper authenticated the Paris-Green waste disposal site as the source of contamination. Mechanism of ground water contamination from this disposal site had been probed by a systematic hydrogeological survey and the arsenic content of the tube-well waters in the surrounding areas. Hydraulic conductivity was maximum in the central part. The site for disposal of the effluent was a ditch located in the zone of discharge. Sparingly soluble Paris-Green cumulatively deposited in the waste disposal site is decomposed by micro-organisms to water-soluble forms and finally percolated to underground aquifers along with rain water through the discharge zone. The contaminant is currently moving towards WNW with ground water flow and the residents in the direction of encroaching contamination are insecure due to penetration of the contaminant.

  5. CLOVERLEAF CYCLOTRON

    Science.gov (United States)

    McMillan, E.M.; Judd, D.L.

    1959-02-01

    A cyclotron is presented embodying a unique magnetic field configuration, which configuration increases in intensity with radius and therefore compensates for the reltivistic mass effect, the field having further convolutions productive of axial stability in the particle beam. By reconciling the seemingly opposed requirements of mass increase compensation on one hand and anial stability on the other, the production of extremely high current particle beams in the relativistie energy range is made feasible. Certain further advantages inhere in the invention, notably an increase in the usable magnet gap, simplified and more efficient extraction of the beam from the accelerator, and ready adaptation to the use of multiply phased excitation as contrasted with the single phased systems herstofore utilized. General

  6. A Study On Utilisation Of Health Services In A Muslim Slum Community Of Calcutta

    Directory of Open Access Journals (Sweden)

    Bhattacharya S.K

    1991-01-01

    Full Text Available A cross- sectional survey of utilization of child immunization and family planning services was carried out in a systematic random sample of 100 families from a Muslim slum community of Calcutta. 15.6% of children (1-4 years were fully immunized (DPT, OPV & BCG. Couple protection rate was 28.4%. But interestingly, the proportion of protected eligible couples in single families (32.8% was significantly higher than in joint families (11.6%.

  7. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  8. Characterization of novel microsatellite markers in Musa acuminata subsp. burmannicoides, var. Calcutta 4

    Directory of Open Access Journals (Sweden)

    Amorim Edson P

    2010-05-01

    Full Text Available Abstract Background Banana is a nutritionally important crop across tropical and sub-tropical countries in sub-Saharan Africa, Central and South America and Asia. Although cultivars have evolved from diploid, triploid and tetraploid wild Asian species of Musa acuminata (A genome and Musa balbisiana (B genome, many of today's commercial cultivars are sterile triploids or diploids, with fruit developing via parthenocarpy. As a result of restricted genetic variation, improvement has been limited, resulting in a crop frequently lacking resistance to pests and disease. Considering the importance of molecular tools to facilitate development of disease resistant genotypes, the objectives of this study were to develop polymorphic microsatellite markers from BAC clone sequences for M. acuminata subsp. burmannicoides, var. Calcutta 4. This wild diploid species is used as a donor cultivar in breeding programs as a source of resistance to diverse biotic stresses. Findings Microsatellite sequences were identified from five Calcutta 4 BAC consensi datasets. Specific primers were designed for 41 loci. Isolated di-nucleotide repeat motifs were the most abundant, followed by tri-nucleotides. From 33 tested loci, 20 displayed polymorphism when screened across 21 diploid M. acuminata accessions, contrasting in resistance to Sigatoka diseases. The number of alleles per SSR locus ranged from two to four, with a total of 56. Six repeat classes were identified, with di-nucleotides the most abundant. Expected heterozygosity values for polymorphic markers ranged from 0.31 to 0.75. Conclusions This is the first report identifying polymorphic microsatellite markers from M. acuminata subsp. burmannicoides, var. Calcutta 4 across accessions contrasting in resistance to Sigatoka diseases. These BAC-derived polymorphic microsatellite markers are a useful resource for banana, applicable for genetic map development, germplasm characterization, evolutionary studies and marker

  9. Characterization of novel microsatellite markers in Musa acuminata subsp. burmannicoides, var. Calcutta 4.

    Science.gov (United States)

    Miller, Robert Ng; Passos, Marco An; Menezes, Natalia Np; Souza, Manoel T; do Carmo Costa, Marcos M; Rennó Azevedo, Vânia C; Amorim, Edson P; Pappas, Georgios J; Ciampi, Ana Y

    2010-05-27

    Banana is a nutritionally important crop across tropical and sub-tropical countries in sub-Saharan Africa, Central and South America and Asia. Although cultivars have evolved from diploid, triploid and tetraploid wild Asian species of Musa acuminata (A genome) and Musa balbisiana (B genome), many of today's commercial cultivars are sterile triploids or diploids, with fruit developing via parthenocarpy. As a result of restricted genetic variation, improvement has been limited, resulting in a crop frequently lacking resistance to pests and disease. Considering the importance of molecular tools to facilitate development of disease resistant genotypes, the objectives of this study were to develop polymorphic microsatellite markers from BAC clone sequences for M. acuminata subsp. burmannicoides, var. Calcutta 4. This wild diploid species is used as a donor cultivar in breeding programs as a source of resistance to diverse biotic stresses. Microsatellite sequences were identified from five Calcutta 4 BAC consensi datasets. Specific primers were designed for 41 loci. Isolated di-nucleotide repeat motifs were the most abundant, followed by tri-nucleotides. From 33 tested loci, 20 displayed polymorphism when screened across 21 diploid M. acuminata accessions, contrasting in resistance to Sigatoka diseases. The number of alleles per SSR locus ranged from two to four, with a total of 56. Six repeat classes were identified, with di-nucleotides the most abundant. Expected heterozygosity values for polymorphic markers ranged from 0.31 to 0.75. This is the first report identifying polymorphic microsatellite markers from M. acuminata subsp. burmannicoides, var. Calcutta 4 across accessions contrasting in resistance to Sigatoka diseases. These BAC-derived polymorphic microsatellite markers are a useful resource for banana, applicable for genetic map development, germplasm characterization, evolutionary studies and marker assisted selection for traits.

  10. ELECTRON CYCLOTRON WAVES

    NARCIS (Netherlands)

    Westerhof, E.

    2010-01-01

    This lecture gives an overview of heating and current drive with electron cyclotron waves. We present the main theoretical aspects of wave propagation, wave absorption, and non-inductive current drive, as well as important technical aspects for the application of high power electron cyclotron waves,

  11. Electron cyclotron waves

    NARCIS (Netherlands)

    Westerhof, E.

    2012-01-01

    This lecture gives an overview of heating and current drive with electron cyclotron waves. We present the main theoretical aspects of wave propagation, wave absorption, and non-inductive current drive, as well as important technical aspects for the application of high power electron cyclotron waves,

  12. Electron cyclotron waves

    NARCIS (Netherlands)

    Westerhof, E.

    2008-01-01

    This lecture gives an overview of heating and current drive with electron cyclotron waves. We present the main theoretical aspects of wave propagation, wave absorption, and non-inductive current drive, as well as important technical aspects for the application of high power electron cyclotron waves,

  13. Studies on macrobenthic organisms in relation to water parameters at East Calcutta Wetlands.

    Science.gov (United States)

    Basu, Arnab; Sengupta, Shruti; Dutta, Sudipta; Saha, Atrayee; Ghosh, Prantik; Roy, Sheela

    2013-07-01

    East Calcutta Wetlands is an internationally important site for natural remediation of domestic sewage and organic waste and their successful recycling into habitat for pisciculture. Macrobenthic fauna is responsible for efficient utilization of sediments and their diversity indicates health of a wetland in accordance to its sediment quality. In the present study, several physico-chemical parameters such as DO (3.03-11.06 ppm), CO2 (4.02-20.0 ppm), alkalinity (36.83-164.0 ppm), total hardness (100.0-270.00 ppm), TDS (450.0-620 ppm), chloride(142.0-364.2 ppm), pH (7.3-8.5), water transparency (8.0-54.2 cm), organic contents like organic carbon (1.03-10.9 mg g(-1)) were studied. Variation in macrobenthic fauna from the selected fields were also examined by calculating Simpson's dominance index, evenness index (Pielou index), Shannon's diversity index. 12 taxa of mollusk and 1 taxa of annelid were found in the study and Bellamyo and Thiara were the most dominant species which indicated clean water of the pond. The correlation between macrobenthic diversity and physico-chemical parameters were also studied in selected ponds from East Calcutta Wetlands.

  14. Analysis of expressed sequence tags from Musa acuminata ssp. burmannicoides, var. Calcutta 4 (AA) leaves submitted to temperature stresses

    NARCIS (Netherlands)

    Santos, C.R.; Martins, N.F.; Horberg, H.M.; Almeida, E.R.P.; Coelho, M.C.F.; Togawa, R.; Silva, F.R.; Caetano, A.R.; Miller, R.N.G.; Souza, M.T.

    2005-01-01

    In order to discover genes expressed in leaves of Musa acuminata ssp. burmannicoides var. Calcutta 4 (AA), from plants submitted to temperature stress, we produced and characterized two full-length enriched cDNA libraries. Total RNA from plants subjected to temperatures ranging from 5°C to 25°C and

  15. Synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The electromagnetic coil which forms the first section of the proton extraction channel in the improved synchro-cyclotron. The photograph shows the positioning gear and the current septum. An extraction efficiency above 50% is expected.

  16. A study on the waste metal remediation using floriculture at East Calcutta Wetlands, a Ramsar site in India.

    Science.gov (United States)

    Chatterjee, Soumya; Singh, Lokendra; Chattopadhyay, Buddhadeb; Datta, Siddhartha; Mukhopadhyay, S K

    2012-08-01

    Use of specific plant species in remediation of heavy metal-contaminated soil and water was a promising eco-friendly technology. The present study indicated the possibilities of phytoremediation of metal-contaminated (namely Ca, Cr, Mn, Fe, Cu, Zn, and Pb) soil by using plant species important for floriculture of East Calcutta Wetlands, a Ramsar site at the eastern fringe of Calcutta city. Plant species like sunflower (Helianthus annuus), marigold (Tagetes patula), and cock's comb (Celocia cristata) grew on soil contaminated by industrial sludge and irrigated regularly with wastewater accumulated different metals in different plant parts in varied concentrations. Pot culture study in the laboratory setup was also done to ascertain the efficiency of these plants for ameliorating contaminated soil. It was found that general accumulation patterns of metals concerned in different plant parts were root > leaf > stem > flower. This work indicated the importance of cultivation of economically important, non-edible, ornamental plant species as an alternative cost-effective practice to remediate heavily contaminated farmlands of East Calcutta Wetlands.

  17. Production of cyclotron radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Yong Sup; Lim, Sang Moo; Yang, Seung Dae; Chun, Kwon Soo; Ahn, Soon Hyuk; Yun, Yong Kee; Park, Hyun; Lee, Ji Sup; Lee, Jong Doo; Chai, Jong Seo; Kim, Yoo Seok; Hong, Sung Suk; Lee, Min Yong; Beak, Seung Ki [Korea Cancer Center Hospital, Seoul (Korea)

    1999-12-01

    In the project, 11,492mCi of {sup 201}Tl, 4,384mCi of {sup 67}Ga, 1,245mCi of {sup 123}l, 523mCi of [{sup 123}I]mlBG and 1,283mCi of {sup 18}FDG were supplied, and the revenue were 304,723,000won. In the production of RI, 13 deg for {sup 201}Tl and {sup 67}Ga, 45 deg for {sup 123}l angle solid target have been used, and liquid target system has been used for {sup 18}F production. For the efficient use of the cyclotron, the MC-50 cyclotron was opened to outside user and basic research project was carried out. The technical supports and radionuclides analysis were done during the execution of the research. Then the facilities of safety supervision and handling techniques of radioisotope production were improved. 7 refs., 9 figs., 8 tabs. (Author)

  18. Production of cyclotron radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kwon Soo; Lim, Sang Moo; Yang, Seung Dae; Suh, Yong Sup; Ahn, Soon Hyuk; Yun, Yong Kee; Park, Hyun; Lee, Ji Sup; Chai, Jong Seo; Kim, Yoo Seok; Hong, Sung Suk; Lee, Min Yong; Beak, Seung Ki; Kim, Jang Hye; Kim, Gi Sup [Korea Cancer Center Hospital, Seoul (Korea)

    2000-12-01

    In the project, 12,077mCi of {sup 201}Tl, 5,717mCi of {sup 67}Ga, 2,096mCi of {sup 123}l, 482mCi of [{sup 123}I]mlBG and 2,738mCi of {sup 18}FDG were supplied, and the revenue were 387,253,000won. In the production of RI, 13 deg for {sup 201}Tl and {sup 67}Ga, 45 deg for {sup 123}l angle solid target have been used, and liquid target system has been used for {sup 18}F production. For the efficient use of the cyclotron, the MC-50 cyclotron was opened to outside user and basic research project was carried out. The technical supports and radionuclides analysis were done during the execution of the research. Then the facilities of safety supervision and handling techniques of radioisotope production were improved. 7 refs., 8 figs., 9 tabs. (Author)

  19. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  20. Ion cyclotron resonance cell

    Science.gov (United States)

    Weller, R.R.

    1995-02-14

    An ion cyclotron resonance cell is disclosed having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions. 5 figs.

  1. EC-5 fifth international workshop on electron cyclotron emission and electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Prater, R.; Lohr, J. [eds.

    1985-12-31

    This report contains papers on the following topics: electron cyclotron emission measurements; electron cyclotron emission theory; electron cyclotron heating; gyrotron development; and ECH systems and waveguide development. These paper have been indexed separately elsewhere. (LSP).

  2. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  3. BEST medical radioisotope production cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Sabaiduc, Vasile; Milton, Bruce; Suthanthiran, Krishnan; Johnson, Richard R. [Best Cyclotron Systems Inc., 7-8765 Ash Street, Vancouver, British Columbia, V6P 6T3 (Canada); Gelbart, W. Z. [Advanced System Designs Inc., 5295 Bear Bay Road, Garden Bay, BC, V0N 1S1 (Canada)

    2013-04-19

    Best Cyclotron Systems Inc (BCSI) is currently developing 14 MeV, 25 MeV, 35MeV and 70MeV cyclotrons for radioisotope production and research applications as well as the entire spectrum of targets and nuclear synthesis modules for the production of Positron Emission Tomography (PET), Single Photon Emission Computed Tomography (SPECT) and radiation therapy isotopes. The company is a subsidiary of Best Medical International, renowned in the field of medical instrumentation and radiation therapy. All cyclotrons have external negative hydrogen ion sources, four radial sectors with two dees in opposite valleys, cryogenic vacuum system and simultaneous beam extraction on opposite lines. The beam intensity ranges from 400 {mu}A to 1000 {mu}A, depending on the cyclotron energy and application.

  4. Cyclotron for Beam Therapy Application

    CERN Document Server

    Alenitsky, Yu G; Karamysheva, G A; Kostromin, S A; Mitsyn, G V; Molokanov, A G; Onishchenko, L M; Samsonov, E V; Vorozhtsov, S B; Zaplatin, N L

    2005-01-01

    The basic parameters of the proton isochronous cyclotron on the fixed energy are considered. The energy of protons is $E_{p}\\sim $ 220~MeV, intensity of the extracted beam is $I_{p}\\sim $ 0.1~$\\mu$A. The cyclotron is projected on the basis of compact magnet with four sectors and the diameter of poles 300 cm. Two dees of the accelerating system are located in valleys.

  5. Immediate hypersensitivity to common food allergens: an investigation on food sensitization in respiratory allergic patients of calcutta, India.

    Science.gov (United States)

    Mandal, Jyotshna; Das, Mahasweta; Roy, Indrani; Chatterjee, Soma; Barui, Nimai Chandra; Gupta-Bhattacharya, Swati

    2009-01-01

    : Food allergy may be defined as an immunoglobulin E-mediated immune response to food proteins. Such studies have previously not been done in Calcutta, India. The present study was therefore undertaken to record the sensitivity to commonly consumed foods in patients with allergic rhinitis and asthma. : A survey of 800 patients (410 males and 390 females) reporting to the Allergy Unit of the Institute of Child Health, Calcutta, were selected for the study conducted from May 2006 to April 2007. Respiratory allergic patients in the age group of 5 to 60 years were evaluated using a standard questionnaire, and skin prick test was performed using common food and aeroallergens. : Out of the 684 patients with a history of food allergy, most of them, that is, 338, are in the age group 16 to 40 years, 192 of them were in the age group 41 to 60 years, and 154 were in the age group 5 to 15 years. Most of the patients with food allergy had asthma (65.05%), rhinitis and asthma (20.03%), and skin allergies (4.97%), such as itching, eczema, and urticaria. The foodstuffs that were found to elicit symptoms of hypersensitivity were egg, milk, wheat, pulses, vegetables, fishes, and fruits.The patients aged between 16 and 40 years (male-female ratio, 1:1.19) were mostly sensitive to prawn, brinjal, banana, ladyfinger, papaya, wheat, and egg. The age group 41 to 60 years (male-female ratio, 1:1.04) had high skin reactivity to brinjal, egg, banana, fish, and Phaseolus mungo. Patients younger than 16 years (male-female ratio, 1:1.33) were sensitized to brinjal, prawn, banana, spinach, and egg. We observed that food hypersensitivity also reflects different genetic factors and variations in cultural and dietary habits of each individual.

  6. Multicavity proton cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    J. L. Hirshfield

    2002-08-01

    Full Text Available A mechanism for acceleration of protons is described, in which energy gain occurs near cyclotron resonance as protons drift through a sequence of rotating-mode TE_{111} cylindrical cavities in a strong nearly uniform axial magnetic field. Cavity resonance frequencies decrease in sequence from one another with a fixed frequency interval Δf between cavities, so that synchronism can be maintained between the rf fields and proton bunches injected at intervals of 1/Δf. An example is presented in which a 122 mA, 1 MeV proton beam is accelerated to 961 MeV using a cascade of eight cavities in an 8.1 T magnetic field, with the first cavity resonant at 120 MHz and with Δf=8 MHz. Average acceleration gradient exceeds 40 MV/m, average effective shunt impedance is 223 MΩ/m, but maximum surface field in the cavities does not exceed 7.2 MV/m. These features occur because protons make many orbital turns in each cavity and thus experience acceleration from each cavity field many times. Longitudinal and transverse stability appear to be intrinsic properties of the acceleration mechanism, and an example to illustrate this is presented. This acceleration concept could be developed into a proton accelerator for a high-power neutron spallation source, such as that required for transmutation of nuclear waste or driving a subcritical fission burner, provided a number of significant practical issues can be addressed.

  7. Hydrodynamic Tests in the N.A.C.A. Tank of a Model of the Hull of the Short Calcutta Flying Boat

    Science.gov (United States)

    Ward, Kenneth E

    1937-01-01

    The hydrodynamic characteristics of a model of the hull of the Short Calcutta (N.A.C.A. Model 47) are presented in non-dimensional form. This model represents one of a series of hulls of successful foreign and domestic flying boats the characteristics of which are being obtained under similar test conditions in the N.A.C.A. tank. The take-off distance and time for a flying boat having the hull of the Calcutta are compared at two values of the gross load with the corresponding distances and times for the same flying boat having hulls of two representative American types, the Sikorsky S-40 and the N.A.C.A. 11-A. This comparison indicates that for hulls of the widely different forms compared, the differences in take-off time and distance are negligible.

  8. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Jong Seo; Lee, Dong Hoon; Kim, You Seok; Park, Chan Won; Lee, Yong Min; Hong, Sung Seok; Lee, Min Yong

    1995-12-01

    The first cyclotron in Korea, MC-59 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-70 .mu.A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed. (author). 8 tabs., 17 figs., 10 refs.

  9. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60{mu}A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed.

  10. Analysis of expressed sequence tags from Musa acuminata ssp. burmannicoides, var. Calcutta 4 (AA) leaves submitted to temperature stresses.

    Science.gov (United States)

    Santos, C M R; Martins, N F; Hörberg, H M; de Almeida, E R P; Coelho, M C F; Togawa, R C; da Silva, F R; Caetano, A R; Miller, R N G; Souza, M T

    2005-05-01

    In order to discover genes expressed in leaves of Musa acuminata ssp. burmannicoides var. Calcutta 4 (AA), from plants submitted to temperature stress, we produced and characterized two full-length enriched cDNA libraries. Total RNA from plants subjected to temperatures ranging from 5 degrees C to 25 degrees C and from 25 degrees C to 45 degrees C was used to produce a COLD and a HOT cDNA library, respectively. We sequenced 1,440 clones from each library. Following quality analysis and vector trimming, we assembled 2,286 sequences from both libraries into 1,019 putative transcripts, consisting of 217 clusters and 802 singletons, which we denoted Musa acuminata assembled expressed sequence tagged (EST) sequences (MaAES). Of these MaAES, 22.87% showed no matches with existing sequences in public databases. A global analysis of the MaAES data set indicated that 10% of the sequenced cDNAs are present in both cDNA libraries, while 42% and 48% are present only in the COLD or in the HOT libraries, respectively. Annotation of the MaAES data set categorized them into 22 functional classes. Of the 2,286 high-quality sequences, 715 (31.28%) originated from full-length cDNA clones and resulted in a set of 149 genes.

  11. Interaction of physical activity level and metabolic syndrome among the adult Asian Indians living in Calcutta, India.

    Science.gov (United States)

    Das, M; Pal, S; Ghosh, A

    2012-01-01

    The present community-based cross-sectional study was aimed to study the interaction of physical activity level (PAL) and metabolic syndrome (MS) among the adult Asian Indians. A total of 448 adult (> 30 years) individuals (males and females) inhabiting in and around Calcutta, India participated in the study. Anthropometric measures, blood pressure, metabolic profiles and intake of dietary fatty acids were obtained from participants using standard guidelines. Metabolic syndrome (MS) was defined accordingly. The dietary intake (gram/week) of fatty acids namely total fat (TFA); saturated fatty acids (SFA); monounsaturated fatty acids (MUFA) and polyunsaturated fatty acids (PUFA) were obtained using nutritive values of Indian foodstuffs. Physical activity level (PAL) was categorized in to three different level: 1) high PAL - who exercised regularly and had physically demanding occupation 2) moderate PAL - who either exercised regularly or had physically demanding occupation, and 3) low PAL - who neither exercised regularly nor had physically demanding occupation. The prevalence of MS was found to be inversely related with PAL. Individuals with low PAL had higher prevalence of MS as compared to their counterparts. Moreover individuals with low PAL had significantly higher BMI, WC, WHR as well as TFA and SFA than individuals with moderate and high PAL. PAL is playing a vital role in the constellation of risk factors associated with MS. Habitual physical activity may be beneficial to prevent growing incidence of MS phenotypes in people of Asian Indian origin.

  12. Cyclotron transitions of bound ions

    Science.gov (United States)

    Bezchastnov, Victor G.; Pavlov, George G.

    2017-06-01

    A charged particle in a magnetic field possesses discrete energy levels associated with particle rotation around the field lines. The radiative transitions between these levels are the well-known cyclotron transitions. We show that a bound complex of particles with a nonzero net charge displays analogous transitions between the states of confined motion of the entire complex in the field. The latter bound-ion cyclotron transitions are affected by a coupling between the collective and internal motions of the complex and, as a result, differ from the transitions of a "reference" bare ion with the same mass and charge. We analyze the cyclotron transitions for complex ions by including the coupling within a rigorous quantum approach. Particular attention is paid to comparison of the transition energies and oscillator strengths to those of the bare ion. Selection rules based on integrals of collective motion are derived for the bound-ion cyclotron transitions analytically, and the perturbation and coupled-channel approaches are developed to study the transitions quantitatively. Representative examples are considered and discussed for positive and negative atomic and cluster ions.

  13. Identification of Differentially-Expressed Genes in Response to Mycosphaerella fijiensis in the Resistant Musa Accession 'Calcutta-4' Using Suppression Subtractive Hybridization.

    Directory of Open Access Journals (Sweden)

    Eduardo Sánchez Timm

    Full Text Available Bananas and plantains are considered an important crop around the world. Banana production is affected by several constraints, of which Black Sigatoka Disease, caused by the fungus Mycosphaerella fijiensis, is considered one of the most important diseases in banana plantations. The banana accession 'Calcutta-4' has a natural resistance to Black Sigatoka; however, the fruit is not valuable for commercialization. Gene identification and expression studies in 'Calcutta-4' might reveal possible gene candidates for resistant to the disease and elucidate mechanisms for resistance. A subtracted cDNA library was generated from leaves after 6, 9 and 12 days inoculated with M. fijiensis conidia on greenhouse banana plants of the accession 'Calcutta-4'. Bioinformatic analysis revealed 99 good quality sequences. Blast2go analysis revealed that 31% of the sequences could not be categorized and, according to the Biological Process Category, 32 and 28 ESTs are related to general metabolic and cellular processes, respectively; while 10 ESTs response to stimulus. Seven sequences were redundant and one was similar to genes that may be involved in pathogen resistance including the putative disease resistance protein RGA1. Genes encoding zinc finger domains were identified and may play an important role in pathogen resistance by inducing the expression of downstream genes. Expression analysis of four selected genes was performed using RT-qPCR during the early stage of the disease development at 6, 9, 12 and 15 days post inoculation showing a peak of up regulation at 9 or 12 days post inoculation. Three of the four genes showed an up-regulation of expression in 'Calcutta-4' when compared to 'Williams' after inoculation with M. fijiensis, suggesting a fine regulation of specific gene candidates that may lead to a resistance response. The genes identified in early responses in a plant-pathogen interaction may be relevant for the resistance response of 'Calcutta-4' to

  14. TRIUMF cyclotron vacuum system refurbishing

    Science.gov (United States)

    Sekachev, I.

    2008-03-01

    The cyclotron at TRIUMF was commissioned to full energy in 1974. The volume of the cyclotron vacuum tank is about 100 m3 and it operates at 5×10-8 Torr pressure during beam production. The pumping is mainly based on a Phillips B-20 cryogenerator (Stirling cycle 4-cylinder engine). The cryogenerator supplies helium gas at 16 K and 70 K to cryopanels in the tank. The decreasing reliability of the B-20 and demanding maintenance requirements triggered the decision to completely overhaul or replace the cryogenerator. Replacement with the LINDE-1630 helium refrigerator was found to be the most attractive (technically and economically) option. The details of the proposal with installation of the helium refrigerator and with a continuous flow liquid nitrogen shield cooling system are presented.

  15. The development of cyclotron radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to developthe radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with {sup 12}'3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism.

  16. Method and apparatus for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  17. 76 FR 80982 - International Cyclotron, Inc., Hato Rey, Puerto Rico; Order Suspending Licensed Activities

    Science.gov (United States)

    2011-12-27

    ...-0292] International Cyclotron, Inc., Hato Rey, Puerto Rico; Order Suspending Licensed Activities I International Cyclotron, Inc. (International Cyclotron; Licensee) is the holder of Byproduct Materials License... International Cyclotron submitted its NRC license application related to the cyclotron, it requested...

  18. Cyclotron Line Measurements with INTEGRAL

    Science.gov (United States)

    Pottschmidt, K.; Kreykenbohm, I.; Caballero, I.; Fritz, S.; Schoenherr, G.; Kretschmar, P.; Wilms, J.; McBride, V. A.; Suchy, S.; Rothschild, R. E.

    2008-01-01

    Due to its broadband energy coverage, INTEGRAL has made important contributions to observing and interpreting cyclotron lines, which are present in the 10-100 keV range of a sample of accreting pulsars. In these systems photons with energies fulfilling the resonance condition inelastically Compton scatter off electrons quantized in the accretion column above the neutron star's magnetic pole(s). This process gives rise to the broad, absorption-like lines or 'cyclotron resonant scattering features' (CRSF). The observed lines allow to directly measure the B-fields of these sources, resulting in values of a few times 1E12G. In this overview I will present recent highlights regarding CRSF observations as well as discuss current ideas and models for the physical conditions in the accretion column. Among the former are the stability of the spectrum of Vela X-1 during giant flares in 2003, the observation of three cyclotron lines during the 2004 outburst of V0332+53, the confirmation of the fundamental line at approximately 45 keV during a 2005 normal outburst of A0535-26, and the simultaneous detection of the two lines in the dipping source 4U 1907+09 (for which also a torque reversal was detected for the first time). Through these and other observations it has become increasingly apparent that two types of observations can potentially be used to constrain the accretion column geometry: the determination of energy ratios for multiple harmonic lines (only two sources with greater than 2 lines are known), was well as the evolution of the fundamental line centroid, which, for different sources, may or may not be correlated with flux. Furthermore, first steps have been taken away from the usual phenomenological description of the lines, towards a physical approach based on self-consistent CRSF modeling. Initial applications are presented.

  19. Radiation surveillance in and around cyclotron facility

    Science.gov (United States)

    Kaur, Amandeep; Sharma, Sarika; Mittal, BR

    2012-01-01

    The cyclotron is the most widely used particle accelerator for producing medically important radio nuclides. Many medical centers in India have installed compact medical cyclotrons for on-site production of short-lived positron-emitting radio nuclides such as 18F, 13N, and 11C. A mandatory requirement for cyclotron installation is radiation control permit from Atomic Energy Regulatory Board. Cyclotron radiation survey is an integral part of the overall radiation safety in the cyclotron facility. Radiation surveillance in and around a newly installed cyclotron was performed using ionization chamber counter and Geiger Muller counter before, during and after operating the cyclotron. The readings were recorded at various locations where a high radiation field was expected. The results were recorded, tabulated and analyzed. The highest exposure level (0.93 μSv) was found at the back wall of the radiochemistry lab facing the cyclotron vault. Reason for the high exposure of 0.93 μSv/h: Synthesis of 18F-Fluoro-Deoxy-Glucose (18F-FDG) was going in the synthesis module and activity (18F) was present in the synthesis module when reading was taken. All other values were found to be below the recommended levels of exposure. PMID:24019654

  20. Developing the smallest possible medical cyclotron

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    Imagine a portable medical cyclotron operated in a conventional radioactive facility at a hospital. Imagine a nurse or technician switching it on and producing isotopes at the patient’s bedside. Sounds like science fiction? Think again.   CERN has teamed up with Spain’s national scientific research centre (CIEMAT) to develop an avant-garde cyclotron to be used for Positron Emission Tomography (PET). “We plan to make a cyclotron that doesn't need an insulated building or ‘vault’: a cyclotron small enough to fit inside a hospital lift,” explains Jose Manuel Perez, who is leading the CIEMAT/CERN collaboration. “It will be the smallest possible medical cyclotron for single patient dose production and will dramatically reduce costs for hospitals.” While PET technology has transformed imaging techniques, many of its medical benefits have remained confined to highly specialised hospitals. “Studies have foun...

  1. Construction and partial sequencing of a subtractive library in Calcutta 4 (Musa AA in early stage of infection with Mycosphaerella fijiensis Morelet

    Directory of Open Access Journals (Sweden)

    Milady Mendoza-Rodríguez

    2006-10-01

    Full Text Available The study of genes involved in plant defense response against pathogen attack, is one of most important steps leading to the elucidation of disease resistance molecular mechanisms. The generation of subtracted deoxyribonucleic acid libraries (cDNA, by means of suppression subtractive hybridization technique (SSH, has been used for this purpose. A subtractive hybridization was made between a cDNA population obtained from ‘Calcutta 4’ inoculated leaves with M. fijiensis (CCIBP-Pf83 and a mixture of cDNA from ‘Calcutta 4’ non inoculated leaves and mycelium. Leaves samples were taken at 6, 10 and 12 days after inoculation. The subtracted library was obtained by cloning and transformation of subtracted products and as a result, 600 recombinants clones were obtained. Sequence analysis of sixty nine clones, revealed redundancy of the expressed sequence tags and most of them showed no homology with reported sequences at databases and only 13 % had a high homology with metalothioneins. The results constitute a step in advance in the molecular study of Musa-Mycosphaerella fijiensis interaction. Key words: Banana-Mycosphaerella fijiensis interaction, BlackSigatoka, Musa spp., suppression subtractive hybridization

  2. Cyclotrons: From Science to Human Health

    Science.gov (United States)

    Craddock, Michael

    2011-04-01

    Lawrence's invention of the cyclotron, whose 80th anniversary we have just celebrated, not only revolutionized nuclear physics, but proved the starting point for a whole variety of recirculating accelerators, from the smallest microtron to the largest synchrotron, that have had an enormous impact in almost every branch of science and in several areas of medicine and industry. Cyclotrons themselves have proved remarkably adaptable, incorporating a variety of new ideas and technologies over the years: frequency modulation, edge focusing, AG focusing, separate magnet sectors, axial and azimuthal injection, ring geometries, stripping extraction, superconducting magnets and rf...... Even FFAGs, those most complex members of the cyclotron (fixed-magnetic-field) family, are making a comeback. Currently there are more than 50 medium or large cyclotrons around the world devoted to research. These provide intense primary beams of protons or stable ions, and correspondingly intense secondary beams of neutrons, pions, muons and radioactive ions, for experiments in nuclear, particle and condensed-matter physics, and in the materials and life sciences. Far outnumbering these, however, are the 800 or so small and medium cyclotrons used to produce radioisotopes for medical and other purposes. In addition, a rapidly growing number of 230-MeV proton cyclotrons are being built for cancer therapy -12 brought into operation since 1998 and as many more in the works. Altogether, cyclotrons are flourishing!

  3. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  4. 10 GHz ECRIS for Warsaw Cyclotron

    CERN Document Server

    Sudlitz, K

    1999-01-01

    Cusp type, 10 GHz ECRIS has been built and tested earlier. For obtaining intensive beams, more relevant for cyclotron, cusp geometry has been replaced by hexapole. Discharge chamber (stainless steel, 50 mm diameter, 250 mm long) is an extension of a coaxial line, feeding RF (9,6 GHz, up to 200 W) to the plasma. The NdFeB hexapole (0,52 T on the surface) has been used. The axial magnetic field is created by water cooled coils. The axial injection line dedicated to K160 isochronous heavy ion cyclotron has been constructed. The line consists of Glaser lenses, double focusing magnet, solenoid and mirror type inflector. The system provides sufficient transmission of the beam from ECR ion source to the firsts orbits of the cyclotron for m/q ranging from 7 to 2. After successful initial tests which were done in July 1997 the ECRIS serves as an external source for Warsaw Cyclotron.

  5. Cyclotron axial ion-beam-buncher system

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

    1982-02-11

    Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

  6. Building 211 cyclotron characterization survey report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  7. Residual radioactivity at the Milan AVF cyclotron

    Science.gov (United States)

    Birattari, C.; Cantone, M. C.; Ferrari, A.; Silari, M.

    1989-08-01

    γ-ray spectrometry measurements have been carried out at the Cyclotron Laboratory at the Department of Physics of the University of Milan, to evaluate the levels of residual radioactivity after about one year from shut down. Measurements were performed inside the cyclotron and at several points in the accelerator vault and target room, as well as on specific components removed from the beam transport system, on samples of the concrete shields and on residues taken from the cyclotron vacuum chamber. The radionuclides identified and the values of specific activity and dose rate are reported. The results indicate that no particular hazard and waste disposal problems should be encountered at the time of the decommissioning of the facility.

  8. Improving cancer treatment with cyclotron produced radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M. Finn, R.D.

    1992-08-04

    This report describes the author's continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program has 3 interactive components: Radiochemistry /Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section under the DOE grant during the 1989--1992 grant period, will be employed in the Pharmacology and Immunology sections of the DOE grant during the 1992--1995 grant period. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  9. A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes

    DEFF Research Database (Denmark)

    Oosterbeek, J.W.; Bürger, A.; Westerhof, E.

    2008-01-01

    An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) beam...

  10. Electron cyclotron resonance heating on TEXTOR

    NARCIS (Netherlands)

    Westerhof, E.; Hoekzema, J. A.; Hogeweij, G. M. D.; Jaspers, R. J. E.; Schüller, F. C.; Barth, C. J.; Bongers, W. A.; Donne, A. J. H.; Dumortier, P.; van der Grift, A. F.; van Gorkom, J. C.; Kalupin, D.; Koslowski, H. R.; Kramer-Flecken, A.; Kruijt, O. G.; Cardozo, N. J. L.; Mantica, P.; van der Meiden, H. J.; Merkulov, A.; Messiaen, A.; Oosterbeek, J. W.; Oyevaar, T.; Poelman, A. J.; Polman, R. W.; Prins, P. R.; Scholten, J.; Sterk, A. B.; Tito, C. J.; Udintsev, V.S.; Unterberg, B.; Vervier, M.; van Wassenhove, G.

    2003-01-01

    The 110 GHz and the new 140 GHz gyrotron systems for electron cyclotron resonance heating (ECRH) and ECCD on TEXTOR are described and results of ECRH experiments with the 110 GHz system are reported. Central ECRH on Ohmic plasmas shows the presence of an internal electron transport barrier near q =

  11. Microwave power coupling with electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    Electron cyclotron resonance (ECR) plasma was produced at 2.45 GHz using 200 – 750 W microwave power. The plasma was produced from argon gas at a pressure of 2 × 10−4 mbar. Three water-cooled solenoid coils were used to satisfy the ECR resonant conditions inside the plasma chamber. The basic parameters of ...

  12. The Data Cyclotron query processing scheme

    NARCIS (Netherlands)

    Goncalves, R.; Kersten, M.

    2011-01-01

    A grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  13. The Data Cyclotron query processing scheme.

    NARCIS (Netherlands)

    R.A. Goncalves (Romulo); M.L. Kersten (Martin)

    2011-01-01

    htmlabstractA grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  14. Electron-cyclotron-resonance ion sources (review)

    Energy Technology Data Exchange (ETDEWEB)

    Golovanivskii, K.S.; Dougar-Jabon, V.D. [People`s Friendship Univ., Moscow (Russian Federation)

    1992-01-01

    The physical principles are described and a brief survey of the present state is given of ion sources based on electron-cyclotron heating of plasma in a mirror trap. The characteristics of ECR sources of positive and negative ions used chiefly in accelerator technology are presented. 20 refs., 10 figs., 3 tabs.

  15. <600> MeV synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    One of the 14 pancakes of the new magnet coils for the 600 MeV synchro-cyclotron which were wound and coated with epoxy resin on the CERN site. These new coils will replace the present ones which have been in use for more than 14 years but are now showing signs of deteriorations.

  16. Development of the cyclotron radioisotope production technology

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Yong Sup; Chun, K.S.; Yang, S.D.; Lee, J.D.; Ahn, S.H.; Yun, Y.K.; Park, H.; Lee, J.S.; Chai, J.S.; Kim, U.S.; Hong, S.S.; Lee, M.Y.; Park, C.W.; Baik, S. K.; Kim, E. H.; Kim, T. K.; Kim, K. S.; Kim, J. H

    1999-04-01

    The purpose of this study is to contribute the advance of nuclear medicine and to the improvement of human health through the development of various accelerator radionuclides and mass production with automization of production. The results obtained from this study are following: 1) In order to introduce 30 MeV high current cyclotron, the specification of cyclotron has been made, the building site was selected and we drew the draw-up of cyclotron. The cyclotron installation contract was postponed until the financial resources could be secured. 2) For a development high purity 1-123 producing system, a Xe-124 target system, a temperature measurement system of the inner part of the target and a target window were fabricated. A Xe-124 gas target recovery system and a full production system of 1-123 was drew up. 3) For a development of a therapeutic nuclide At-211, a target for the production of At-211 via {sup 209}Bi(alpha, 2n) reaction was fabricated. Produced At-211 was separated by distillation method. 4) For development of beta-emitting nuclides, Ti-45, C-11, F{sub 2}-18, beam irradiation system suitable for each target were fabricated. 5) For automatic production of Ga-67, automated module and PLC program was made 6) For the quality control of radiopharmaceuticals, analytical method of thallium and copper by polarography was investigated and established.

  17. Resonant cyclotron scattering in magnetars' emission

    NARCIS (Netherlands)

    Rea, N.; Zane, S.; Turolla, R.; Lyutikov, M.; Götz, D.

    2008-01-01

    We present a systematic fit of a model of resonant cyclotron scattering (RCS) to the X-ray data of 10 magnetars, including canonical and transient anomalous X-ray pulsars (AXPs) and soft gamma repeaters (SGRs). In this scenario, nonthermal magnetar spectra in the soft X-rays (i.e., below ~10 keV)

  18. Ion cyclotron resonance heating system on Aditya

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    1Institute for Plasma Research, Bhat, Gandhinagar 382 428, India. 2Variable Electron Cyclotron .... Requirements for RF generators for fusion research include high power, long pulse duration and reliability. ... Output of pre-driver (triode 3CX5000A7) grounded grid amplifier is made tunable within. 20 to 47 MHz by using a ...

  19. Program Complex For Cyclotron Beam Dynamic Simulations

    CERN Document Server

    Glazov, A A; Karamysheva, G A; Lisenkova, O E

    2004-01-01

    The program complex in MATLAB intended for particle dynamic simulations is described. Programming in an easy-to-use environment permits creation of models in a short space of time. Advanced graphical tools of MATLAB give good visualization features to created models. The beam dynamic modelling results by the example of two different cyclotron designs are presented.

  20. SC Cyclotron and RIB Facilities in Kolkata

    CERN Document Server

    Sinha, Bikash; Chakrabarti, Alok

    2005-01-01

    The superconducting cyclotron under construction at this Centre has bending limit (K-bend) of 520 and focusing limit (K-foc) of 160. It is being constructed, primarily, for nuclear physics experiments with heavy ion beams at intermediate energies. The 100-ton main magnet is currently in the commissioning phase with the main coil already at 4.2K temperature. Magnetic field measurements will be carried out over the next several months. All other systems of the cyclotron are in an advanced stage of fabrication or development. We plan to start assembly of the complete cyclotron around the end of 2005. In the phase-I of the project one beam line has been provided. Construction of three more beam lines and various experimental facilities for nuclear physics as well as irradiation experiments has also been funded and the work is well on its way. An ISOL type Radioactive Ion Beam (RIB) facility is being built with the existing K=130 room temperature cyclotron, VEC, as the primary beam source. In-beam RIB production a...

  1. Tokamak startup with electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed.

  2. Cyclotron-based neutron source for BNCT

    Science.gov (United States)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-01

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation & treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8×109 neutrons/cm2/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with 10B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  3. Cyclotron-based neutron source for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K. [Sumitomo Heavy Industries, Ltd (Japan); Tanaka, H.; Sakurai, Y.; Maruhashi, A. [Kyoto University Research Reactor Institute (Japan)

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  4. EBCO Technologies TR Cyclotrons, Dynamics, Equipment, and Applications

    Science.gov (United States)

    Johnson, R. R.; Erdman, K. L.; Gyles, Wm.; Burbee, J.; VanLier, E.; Kovacs, M.; Perron, F.

    2003-08-01

    The Ebco Technologies TR cyclotrons have a common parent in the 500 MeV negative ion cyclotron at TRIUMF in Vancouver. As such, the TR cyclotrons have features that can be adapted for specific application. The cyclotron design is modularized into ion source and injection system, central region and then extraction. The cyclotron ion source is configured for cyclotron beam currents ranging from 50 microAmps to 2 milliAmps. The injection line can be operated in either continuous (CW) or in pulsed mode. The center region of the cyclotron is configured to match the ion source configuration. The extracted beams are directed either to a local target station or to beam lines and thence to target stations. There has been development both in solid, liquid and gas targets. There has been development in radioisotope handling techniques, target material recovery and radiochemical synthesis.

  5. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

    Science.gov (United States)

    Nagornov, Konstantin O; Kozhinov, Anton N; Tsybin, Yury O

    2017-04-01

    The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω c . In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω c quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω+), whereas the ω c and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω+ quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω c frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω+ frequencies can be reduced to negligible levels relative to peaks close to ω c frequencies. Due to reduced errors with which the ω c quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω+ frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. Graphical Abstract ᅟ.

  6. Operation of a quasioptical electron cyclotron maser

    Energy Technology Data Exchange (ETDEWEB)

    Morse, E.C.; Pyle, R.V.

    1984-12-01

    The electron cyclotron maser or gyrotron concept has been developed to produce sources producing 200 kW at 28 GHz continuously, and higher power outputs and frequencies in pulsed mode. These sources have been useful in electron cyclotron resonance heating (ECRH) in magnetically confined fusion devices. However, higher frequencies and higher power levels will be required in reactor-grade fusion plasmas, with likely requirements of 1.0 MW or more per source at 140 GHz. Conventional gyrotrons follow a trend of decreasing power for increasing frequency. In order to circumvent this problem, the quasioptical electron cyclotron maser was proposed. In this device, the closed resonator of the conventional gyrotron is replaced with an open, Fabry-Perot type resonator. The cavity modes are then the TEM-type modes of an optical laser. The advantage of this configuration is that the cavity size is not a function of frequency, since the length can be any half-integer number of wavelengths. Furthermore, the beam traverses across the cavity transverse to the direction of radiation output, and thus the rf window design is less complicated than in conventional tubes. The rf output, if obtained by diffraction coupling around one of the mirrors, could be in a TEM mode, which would allow for quasioptical transmission of the microwaves into the plasma in fusion devices. 4 references, 1 figure.

  7. Beam stripping extraction from the VINCY cyclotron

    Directory of Open Access Journals (Sweden)

    Ristić-Đurović Jasna L.

    2006-01-01

    Full Text Available The extraction system of a cyclotron guides an ion beam from a spiral acceleration orbit, through an extraction trajectory, into a high energy transport line. The two methods commonly used to direct an ion into the extraction path are deflection, by the electric field of an electrostatic deflector, and ion stripping, by a thin carbon foil. Compared to the electrostatic deflector system, the stripping extraction provides a fast and easy change of the extracted ion energy and is easier to manufacture operate, and maintain. However, the extraction trajectory and dynamics of an ion beam after stripping are highly dependant on the ion energy and specific charge. Thus, when a multipurpose machine such as the VINCY Cyclotron is concerned, it is far from easy to deliver a variety of ion beams into the same high energy transport line and at the same time preserve a reasonable compactness of the extraction system. The front side stripping extraction system of the VINCY Cyclotron provides high (~70 MeV and mid (~30 MeV energy protons, as well as a number of heavy ions in broad energy ranges. The back side stripping extraction system extracts low energy protons (~18 MeV and enables their simultaneous use with high energy protons at the front side of the machine.

  8. Benchmarking of codes for electron cyclotron heating and electron cyclotron current drive under ITER conditions

    NARCIS (Netherlands)

    Prater, R.; Farina, D.; Gribov, Y.; Harvey, R. W.; Ram, A. K.; Lin-Liu, Y. R.; Poli, E.; Smirnov, A. P.; Volpe, F.; Westerhof, E.; Zvonkovo, A.

    2008-01-01

    Optimal design and use of electron cyclotron heating requires that accurate and relatively quick computer codes be available for prediction of wave coupling, propagation, damping and current drive at realistic levels of EC power. To this end, a number of codes have been developed in laboratories

  9. Electron cyclotron emission diagnostics on KSTAR tokamak.

    Science.gov (United States)

    Jeong, S H; Lee, K D; Kogi, Y; Kawahata, K; Nagayama, Y; Mase, A; Kwon, M

    2010-10-01

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

  10. Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project

    NARCIS (Netherlands)

    Deng, B.H.; Hsia, R. P.; Domier, C.W.; Burns, S. R.; Hillyer, T. R.; N C Luhmann Jr.,; Oyevaar, T.; Donne, A. J. H.; R. T. P. Team,

    1999-01-01

    A 16-channel electron cyclotron emission (ECE) imaging diagnostic system has been developed and installed on the Rijnhuizen Tokamak Project for measuring plasma electron cyclotron emission with a temporal resolution of 2 mu s. The high spatial resolution of the system is achieved by utilizing a low

  11. Cyclotron Lines: From Magnetic Field Strength Estimators to ...

    Indian Academy of Sciences (India)

    Chandreyee Maitra

    2017-09-12

    Sep 12, 2017 ... With forty years since the discovery of the first cyclotron line in Her X-1, there have been remarkable ... the important results related to cyclotron lines since its discovery and reviews their significance. ... context can provide, to build a complete picture for the physics of accretion and hence X-ray emission in.

  12. Ion–Cyclotron Resonance Frequency Interval Dependence on the O ...

    Indian Academy of Sciences (India)

    Solar corona—ion–cyclotron waves—coronal heating—. Vlasov equation. 1. Introduction. Heating of solar corona is still an active research area. It has recently been suggested that the ion–cyclotron resonance could play a key role in the problem of coronal heating. It is generally argued that various electromagnetic plasma ...

  13. Unstable plasma characteristics in mirror field electron cyclotron ...

    Indian Academy of Sciences (India)

    Electron cyclotron plasma reactor are prone to instabilities in specific input power [3–. 7] region (150–450 watts). ... Electron cyclotron resonance (ECR) plasma technology has become very important for fabrication of very large scale ... left hand polarized (LHP) wave. Shufflbotham and Thomson [4] observed several distinct.

  14. Electron Cyclotron Resonance Heating of a High-Density Plasma

    DEFF Research Database (Denmark)

    Hansen, F. Ramskov

    1986-01-01

    Various schemes for electron cyclotron resonance heating of tokamak plasmas with the ratio of electron plasma frequency to electron cyclotron frequency, "»pe/^ce* larger than 1 on axis, are investigated. In particular, a mode conversion scheme is investigated using ordinary waves at the fundamental...

  15. High-current cyclotron to drive an electronuclear assembly

    CERN Document Server

    Alenitsky, Yu G

    2002-01-01

    The proposal on creation of a high-current cyclotron complex for driving an electronuclear assembly reported at the 17th Meeting on Accelerators of Charged Particles is discussed. Some changes in the basic design parameters of the accelerator are considered in view of new results obtained in the recent works. It is shown that the cyclotron complex is now the most real and cheapest accelerator for production of proton beams with a power of up to 10 MW. Projects on design of a high-current cyclotron complex for driving an electronuclear subcritical assembly are presented.

  16. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1993-11-01

    This report describes our continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section will be employed in the Pharmacology and Immunology sections during the next year. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  17. Shielding design of the Mayo Clinic Scottsdale cyclotron vault

    Directory of Open Access Journals (Sweden)

    Riper Kenneth A. Van

    2017-01-01

    Full Text Available Mayo Clinic Scottsdale (Scottsdale, Arizona is building a cyclotron vault containing a cyclotron with adjacent targets and a beam line leading to an external target. The targets are irradiated by high energy (15 to 16.5 MeV protons for the production of radioisotopes. We performed Monte Carlo radiation transport simulations to calculate the radiation dose outside of the vault during irradiation of the cyclotron and external targets. We present the Monte Carlo model including the geometry, sources, and variance reduction methods. Mesh tallies surrounding the vault show the external dose rate is within acceptable limits.

  18. Radiation Monitoring System of 30 MeV Cyclotron

    Directory of Open Access Journals (Sweden)

    Lee Jin-Woo

    2017-01-01

    Full Text Available A state-of-the-art radiation monitoring system was implemented at KAERI for a 30-MeV cyclotron. This system consists of several types of radiation measuring systems for ambient dose equivalent rate measurements of outside photon and neutron areas as well as inside the cyclotron, and monitors the alpha and beta particulates released from a stack, as well as the results of worker contamination at the portal of the cyclotron. In addition, an automatic alarm system is also mounted if there are alarms in the measuring systems.

  19. High-Resolution Ion Cyclotron Mobility Spectrometry

    Science.gov (United States)

    Merenbloom, Samuel I.; Glaskin, Rebecca S.; Henson, Zachary B.; Clemmer, David E.

    2009-01-01

    A novel ion mobility spectrometry instrument incorporating a cyclotron geometry drift tube is presented. The drift tube consists of eight regions, four curved drift tubes and four ion funnels. Packets of ions are propagated around the drift tube by changing the drift field at a frequency that is resonant with the ion’s drift time through each region. The approach trims each packet of ions as it leaves and enters each new region. An electrostatic gate allows ions to be kept in the drift tube for numerous cycles, increasing the ability to resolve specified ions. We demonstrate the approach by isolating the [M+2H]2+ or [M+3H]3+ charge state of substance P as well as individual trisaccharide isomers from a mixture of melezitose and raffinose. Resolving powers in excess of 300 are obtainable with this approach. PMID:19143495

  20. Simulation of cyclotron resonant scattering features

    Directory of Open Access Journals (Sweden)

    Schwarm Fritz-Walter

    2014-01-01

    Full Text Available X-ray binary systems consisting of a mass donating optical star and a highly magnetized neutron star, under the right circumstances, show quantum mechanical absorption features in the observed spectra called cyclotron resonant scattering features (CRSFs. We have developed a simulation to model CRSFs using Monte Carlo methods. We calculate Green’s tables which can be used to imprint CRSFs to arbitrary X-ray continua. Our simulation keeps track of scattering parameters of individual photons, extends the number of variable parameters of previous works, and allows for more flexible geometries. Here we focus on the influence of bulk velocity of the accreted matter on the CRSF line shapes and positions.

  1. Ion cyclotron emission by spontaneous emission

    Energy Technology Data Exchange (ETDEWEB)

    Da Costa, O. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Gresillon, D. [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises

    1994-07-01

    The goal of the study is to examine whether the spontaneous emission can account for ICE (ion cyclotron emission) experimental results, or part of them. A straightforward approach to plasma emission is chosen, investigating the near equilibrium wave radiation by gyrating ions, and thus building from the majority and fast fusion ions the plasma fluctuations and emission on the fast magnetoacoustic or compressional Alfven wave mode in the IC frequency range. Similarities with the ICE experiments are shown: the emission temperature in the presence of fast ions (even in a very small amount), the strong fast ion emission increase with the harmonic, the fine double-line splitting of each peak, the linear but not proportional increase of the peak width with the harmonic. 3 refs., 2 figs.

  2. Single-electron detection and spectroscopy via relativistic cyclotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Asner, David M.; Bradley, Rich; De Viveiros Souza Filho, Luiz A.; Doe, Peter J.; Fernandes, Justin L.; Fertl, M.; Finn, Erin C.; Formaggio, Joseph; Furse, Daniel L.; Jones, Anthony M.; Kofron, Jared N.; LaRoque, Benjamin; Leber, Michelle; MCBride, Lisa; Miller, M. L.; Mohanmurthy, Prajwal T.; Monreal, Ben; Oblath, Noah S.; Robertson, R. G. H.; Rosenberg, Leslie; Rybka, Gray; Rysewyk, Devyn M.; Sternberg, Michael G.; Tedeschi, Jonathan R.; Thummler, Thomas; VanDevender, Brent A.; Woods, N. L.

    2015-04-01

    It has been understood since 1897 that accelerating charges should emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spectrometer. We observe the cyclotron radiation emitted by individual electrons that are produced with mildly-relativistic energies by a gaseous radioactive source and are magnetically trapped. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work is a proof-of-concept for future neutrino mass experiments using this technique.

  3. Neutron field inside a PET Cyclotron vault room

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [UAZ, C. Cipres 10, 98068 Zacatecas (Mexico); Mendez, R. [CIEMAT, Ave. Complutense 22, 28040 Madrid (Spain); Iniguez, M.P. [Universidad de Valladolid, Po Prado de la Magdalena s/n, 47011 Valladolid (Spain); Climent, J.M.; Penuelas, I. [Servicio de Medicina Nuclear de la Clinica Universitaria de Navarra, Pamplona (Spain); Barquero, R. [Hospital Universitario Rio Hortega, Valladolid (Spain)]. e-mail: fermineutron@yahoo.com

    2006-07-01

    The neutron field around a Positron Emission Tomography cyclotron was investigated during {sup 18} F radioisotope production with an 18 MeV proton beam. In this study the Ion Beam Application cyclotron, model Cyclone 18/9, was utilized. Measurements were carried out with a Bonner sphere neutron spectrometer with pairs of thermoluminescent dosemeters (TLD600 and TLD700) as thermal neutron detector. The TLDs readouts were utilized to unfold the neutron spectra at three different positions inside the cyclotron's vault room. With the spectra the Ambient dose equivalent was calculated. Neutron spectra unfolding were performed with the BUNKIUT code and the UTA4 response matrix. Neutron spectra were also determined by Monte Carlo calculations using a detailed model of cyclotron and vault room. (Author)

  4. Vacuum Control Systems of the Cyclotrons in VECC, Kolkata

    Science.gov (United States)

    Roy, Anindya; Akhtar, Javed; Yadav, R. C.; Bhole, R. B.; Pal, Sarbajit; Sarkar, D.; Bhandari, R. K.

    2012-11-01

    VECC has undertaken the modernization of the K-130 Room Temperature Cyclotron (RTC) (operational since 1978) and commissioning of K-500 Superconducting Cyclotron (SCC) at present. The control system of RTC vacuum system has been upgraded to Programmable Logic Controller (PLC) based automated system from relay based manual system. A distributed PLC based system is under installation for SCC vacuum system. The requirement of high vacuum in both the cyclotrons (1×10-6 mbar for RTC and 5 × 10-8 mbar SCC) imposes the reliable local and remote operation of all vacuum components and instrumentation. The design and development of the vacuum control system of two cyclotrons using the Experimental Physics and Industrial Control System (EPICS) distributed real-time software tools are presented.

  5. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 23

    Energy Technology Data Exchange (ETDEWEB)

    1967-10-09

    Progress is reported in the design, installation of various components of the cyclotron, including coils, magnets, rf system, and vacuum system. Also reported are measurements on magnets and rf components. (LEW)

  6. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 20

    Energy Technology Data Exchange (ETDEWEB)

    1967-06-30

    Progress is reported in the fabrication and testing of cyclotron components, including magnet system and rf system components. Work on vacuum components and instrumentation and control equipment is also reported. (LEW)

  7. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 32

    Energy Technology Data Exchange (ETDEWEB)

    1968-06-28

    Completion of magnet tests, followed by completion of installation of major cyclotron components, are reported. Intermediate level power tests of the rf system are also reported. Design and fabrication of the control system are reported to be under way. (LEW)

  8. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 26

    Energy Technology Data Exchange (ETDEWEB)

    1968-01-17

    Progress is reported in the fabrication, installation, and testing of cyclotron components, including magnets and coils, rf components, vacuum and control equipment. Also reported are magnet and rf component measurements. (LEW)

  9. Relativistic Cyclotron Resonance Shape in Magnetic Bottle Geonium

    National Research Council Canada - National Science Library

    Hans Dehmelt; Richard Mittleman; Yuan Liu

    1988-01-01

    The thermally excited axial oscillation of the electron through the weak magnetic bottle needed for the continuous Stern-Gerlach effect modulates the cyclotron frequency and produces a characteristic...

  10. Cryogenic system for VECC K500 superconducting cyclotron

    CERN Document Server

    Pal, G; Bhattacharyya, T K; Bhandari, R K

    2009-01-01

    VEC Centre, Kolkata in India is at an advanced stage of commissioning a K500 superconducting cyclotron. The superconducting coil of the magnet for cyclotron is cooled by liquid helium. Three liquid helium cooled cryopanels, placed inside the Dees of the radiofrequency system, maintain the vacuum in the acceleration region of the superconducting cyclotron. The cryogenic system for magnet for cyclotron has been tested by cooling the coil and energizing the magnet. The cryogenic system for cryopanels has also been tested. Heater and temperature sensor were placed on the liquid helium cold head for cryopanel. The temperature of the cold head was observed to be below 20 K upto a heat load of 11.7 watt.

  11. Design of 10 MeV cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    R Solhju

    2015-09-01

    Full Text Available Design and construction of 10MeV cyclotron has been started at Amirkabir University of Technology since 2012. So far, the conceptual and detail engineering design phases have been finalized. The main purpose of this baby cyclotron is to generate proton beam for the production of PET radioisotopes. The cyclotron consists of magnet, cavity, ion source, RF and LLRF system, vacuum system, cooling system, power amplifiers and power supplies system. In this paper, a brief of design principles for all the parts of cyclotron and their final simulation results is presented. It should be noted that these simulations have been performed and optimized by the most accurate softwares such as TOSCA, ANSYS, HFSS, SolidWorks and CST. Also, the manufacturing feasibility of all the parts is performed and their dimensions and parameters are synchronized with manufacturing standards

  12. A new way to measure the electron cyclotron frequency

    Science.gov (United States)

    Palmer, F. L.

    1993-03-01

    A method is described for using spin flips to measure the 0 to 1 cyclotron transition frequency of a single electron in a Penning trap. Detection can be accomplished with magnetic bottles of 10 T/m2 or less, thereby greatly reducing the thermal broadening of the cyclotron line. This method complements a recently published technique for measuring the anomaly frequency, making a more precise measurement of the electron anomaly ratio possible.

  13. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  14. PET computer programs for use with the 88-inch cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Gough, R.A.; Chlosta, L.

    1981-06-01

    This report describes in detail several offline programs written for the PET computer which provide an efficient data management system to assist with the operation of the 88-Inch Cyclotron. This function includes the capability to predict settings for all cyclotron and beam line parameters for all beams within the present operating domain of the facility. The establishment of a data base for operational records is also described from which various aspects of the operating history can be projected.

  15. Ion source and injection line for high intensity medical cyclotron.

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  16. Electromagnetic cyclotron waves near the proton cyclotron frequency in the solar wind

    Science.gov (United States)

    Jian, Lan K.; Boardsen, Scott; Moya, Pablo; Stevens, Michael; Alexander, Robert; Vinas, Adolfo

    2015-04-01

    Strong narrow-band electromagnetic waves around the proton cyclotron frequency (fpc) have been found sporadically in the solar wind from 0.3 to 0.7 AU during MESSENGER spacecraft’s cruise phase. These waves are transverse and circularly polarized, and they propagate in directions quasi-parallel to the magnetic field. The wave power decreases quadratically with heliocentric distance, faster than the trend if assuming the conservation of Poynting flux for wave packets, suggesting there is energy dissipation from the waves, which could contribute to the heating and acceleration of solar wind plasma. Although the wave frequency is a few times of fpc in the spacecraft frame, it is a fraction of fpc in the solar wind plasma frame after removing the Doppler shift effect. In this frequency range, the waves can be left-hand (LH) polarized ion cyclotron waves or right-hand (RH) polarized magnetosonic waves. Because the waves are LH or RH polarized in the spacecraft frame with otherwise nearly identical characteristics, they could be due to Doppler shift of a same type of waves or a mixture of waves with intrinsically different polarizations. Through the assistance of audification, we have studied the long-lasting wave events in 2005 using high-cadence magnetic field data from the Wind mission. Statistically, in contrast with general solar wind, the protons at these waves are distributed closer to the proton instability thresholds, while the alpha particles at these waves are distributed further away from the alpha instability thresholds. For selected events of extensive waves, the ion distribution is analyzed in detail. A mixture of temperature anisotropies for core protons, beam protons, and alpha particles, as well as proton beam drift are often found in such events. We conduct linear wave dispersion analysis using these ion moments to examine whether these waves can be explained by the local generation of kinetic instabilities such as the LH ion cyclotron, the RH

  17. Correlation electron cyclotron emission diagnostic in TCV

    Science.gov (United States)

    Fontana, M.; Porte, L.; Molina Cabrera, P.

    2017-08-01

    The correlation electron cyclotron emission diagnostic of tokamak à configuration variable has recently been upgraded. It now has the choice of three lines of sight: two horizontal lines placed on the low field side of the vessel, perpendicular to the magnetic field, and a dual-axis steerable antenna. The polarization of the radiation collected by the latter can be rotated using a universal polarizer situated in the transmission line. This line is also shared with a reflectometry system, allowing simultaneous measurements of temperature and density fluctuations in the same plasma volumes. When using this line, it is possible to choose between two dedicated front ends characterized by different local oscillator frequencies, adding flexibility in the choice of the plasma region to be studied. The intermediate frequency section is now equipped with six frequency tunable YIG filters allowing the study of turbulence properties in a wide range of radial positions. When studying fluctuations over the whole video bandwidth, the minimum detectable fluctuation level is δ Te/Te˜0.5 % . The new system has been used to measure electron temperature fluctuations over a large fraction of the plasma profiles in a series of plasmas with triangularity varying from 0.6 to -0.6 but comparable collisionality profiles.

  18. Inverse ion-cyclotron damping and excitation of multiharmonic ion-cyclotron waves in the northern magnetospheric cusp

    Science.gov (United States)

    Slapak, Rikard; Gunell, Herbert; Hamrin, Maria

    2017-04-01

    We have investigated a case of inverse ion-cyclotron damping taking place in the northern terrestrial magnetospheric cusp, exciting waves at the ion-cyclotron frequency and its harmonics. Magnetosheath influx in the cusps and the effect of convection and magnetic mirroring give rise to parallel velocity shears, dvallel/dx\\perp, often associated with instabilities in the plasma and corresponding ion-cyclotron waves, whose evolution is described by a damping factor. This damping factor depends on, for example, the wave numbers and the velocity shear itself and can under certain conditions be negative, hence describing inverse damping (or wave growth). However, an additional required condition for inverse ion-cyclotron damping is a velocity shear in the magnetic field-aligned ion-bulk flow, and this condition is only met for magnetosheath influx in the northern cusp, as oppose to the southern cusp. The ion-cyclotron waves are primarily seen as peaks in the magnetic-field spectral densities, as presented by Slapak et al., [GRL (2016), doi:10.1002/2016GL071680]. The corresponding peaks in the electric-field spectral densities are not as profound, suggesting a background electric field noise or other processes of wave generation causing the electric spectral densities to smoothen out more compared to the magnetic counterpart. We note that some ion-cyclotron wave activity is present in a few similar shear events in the southern cusp, which indicates that other mechanisms generating ion-cyclotron waves may also be present during such conditions.

  19. Design of RF system for CYCIAE-230 superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-11

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push–pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  20. Relativistic Cyclotron Resonance Shape in Magnetic Bottle Geonium

    Science.gov (United States)

    Dehmelt, Hans; Mittleman, Richard; Liu, Yuan

    1988-10-01

    The thermally excited axial oscillation of the electron through the weak magnetic bottle needed for the continuous Stern-Gerlach effect modulates the cyclotron frequency and produces a characteristic ≈ 12-kHz-wide vertical rise-exponential decline line shape of the cyclotron resonance. At the same time the relativistic mass shift decreases the frequency by ≈ 200 Hz per cyclotron motion quantum level n. Nevertheless, our analysis of the complex line shape shows that it should be possible to produce an abrupt rise in the cyclotron quantum number n from 0 to ≈ 20 over a small fraction of 200 Hz, when the 160-GHz microwave drive approaches the n = 0 → 1 transition, and a jump of 14 levels over a frequency increment of 200 Hz has already been observed in preliminary work. This realizes an earlier proposal to generate a very sharp cyclotron resonance feature by quasithermal excitation with a square noise band and should provide a way to detect spin flips when a weak bottle is used to reduce the broadening of the g - 2 resonance by a factor of 20.

  1. Design of RF system for CYCIAE-230 superconducting cyclotron

    Science.gov (United States)

    Yin, Zhiguo; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-01

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push-pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  2. Risk assessment of 30 MeV cyclotron facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Gyo Seong; Lee, Jin Woo [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Kim, Chong Yeal [Dept. of Radiation Science and Technology, Chonbuk National University, Jeonju (Korea, Republic of)

    2017-03-15

    A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce 18F, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fres and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a free. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

  3. 75 FR 48939 - National Superconducting Cyclotron Laboratory of Michigan State University; Notice of Decision on...

    Science.gov (United States)

    2010-08-12

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE International Trade Administration National Superconducting Cyclotron Laboratory of Michigan State University...., NW., Washington, DC. Docket Number: 10-043. Applicant: National Superconducting Cyclotron Laboratory...

  4. Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharjee, Tanushyam; Kanti Dey, Malay; Dhara, Partha; Roy, Suvodeep; Debnath, Jayanta; Balakrishna Bhole, Rajendra; Dutta, Atanu; Pradhan, Jedidiah; Pal, Sarbajit; Pal, Gautam; Roy, Amitava; Chakrabarti, Alok [Variable Energy Cyclotron Centre, 1/AF Bidhannagar, Kolkata 700064 (India)

    2013-05-15

    In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

  5. Calibration of the simulation model of the VINCY cyclotron magnet

    Directory of Open Access Journals (Sweden)

    Ćirković Saša

    2002-01-01

    Full Text Available The MERMAID program will be used to isochronise the nominal magnetic field of the VINCY Cyclotron. This program simulates the response, i. e. calculates the magnetic field, of a previously defined model of a magnet. The accuracy of 3D field calculation depends on the density of the grid points in the simulation model grid. The size of the VINCY Cyclotron and the maximum number of grid points in the XY plane limited by MERMAID define the maximumobtainable accuracy of field calculations. Comparisons of the field simulated with maximum obtainable accuracy with the magnetic field measured in the first phase of the VINCY Cyclotron magnetic field measurements campaign has shown that the difference between these two fields is not as small as required. Further decrease of the difference between these fields is obtained by the simulation model calibration, i. e. by adjusting the current through the main coils in the simulation model.

  6. Cyclotron instabilities driven by temperature anisotropy in the solar wind

    Science.gov (United States)

    Noreen, N.; Yoon, P. H.; Zaheer, S.

    2017-10-01

    Kinetic plasma instabilities are important for regulating the temperature anisotropies of electrons and ions in solar wind. For the low beta regime, it is known that electromagnetic ion/electron cyclotron instabilities are important, but in the literature these unstable modes are discussed under the assumption of parallel propagation. The present paper extends the analysis to two (or with cylindrical symmetry, three) dimensions. The analysis is further extended to include quasilinear description with the assumption of the bi-Maxwellian velocity distribution function. Such an analysis lays the foundation for an eventual study in which cyclotron instabilities as well as obliquely propagating unstable modes such as the mirror instability are simultaneously taken into account. The present paper first lays down the basis for such future efforts in which the two- or three dimensional linear and quasilinear theories of cyclotron instabilities in the low beta regime are formulated.

  7. Calibration of the simulation model of the Vincy cyclotron magnet

    CERN Document Server

    Cirkovic, S; Vorozhtsov, A S; Vorozhtsov, S B

    2002-01-01

    The MERMAID program will be used to isochronise the nominal magnetic field of the VINCY Cyclotron. This program simulates the response, i. e. calculates the magnetic field, of a previously defined model of a magnet. The accuracy of 3D field calculation depends on the density of the grid points in the simulation model grid. The size of the VINCY Cyclotron and the maximum number of grid points in the XY plane limited by MERMAID define the maximum obtainable accuracy of field calculations. Comparisons of the field simulated with maximum obtainable accuracy with the magnetic field measured in the first phase of the VINCY Cyclotron magnetic field measurements campaign has shown that the difference between these two fields is not as small as required. Further decrease of the difference between these fields is obtained by the simulation model calibration, i. e. by adjusting the current through the main coils in the simulation model.

  8. Distribution of thermal neutron flux around a PET cyclotron.

    Science.gov (United States)

    Ogata, Yoshimune; Ishigure, Nobuhito; Mochizuki, Shingo; Ito, Kengo; Hatano, Kentaro; Abe, Junichiro; Miyahara, Hiroshi; Masumoto, Kazuyoshi; Nakamura, Hajime

    2011-05-01

    The number of positron emission tomography (PET) examinations has greatly increased world-wide. Since positron emission nuclides for the PET examinations have short half-lives, they are mainly produced using on-site cyclotrons. During the production of the nuclides, significant quantities of neutrons are generated from the cyclotrons. Neutrons have potential to activate the materials around the cyclotrons and cause exposure to the staff. To investigate quantities and distribution of the thermal neutrons, thermal neutron fluxes were measured around a PET cyclotron in a laboratory associating with a hospital. The cyclotron accelerates protons up to 18 MeV, and the mean particle current is 20 μA. The neutron fluxes were measured during both 18F production and C production. Gold foils and thermoluminescent dosimeter (TLD) badges were used to measure the neutron fluxes. The neutron fluxes in the target box averaged 9.3 × 10(6) cm(-2) s(-1) and 1.7 × 10(6) cm(-2) s(-1) during 18F and 11C production, respectively. Those in the cyclotron room averaged 4.1 × 10(5) cm(-2) s(-1) and 1.2 × 10(5) cm(-2) s(-1), respectively. Those outside the concrete wall shielding were estimated as being equal to or less than ∼3 cm s, which corresponded to 0.1 μSv h(-1) in effective dose. The neutron fluxes outside the concrete shielding were confirmed to be quite low compared to the legal limit.

  9. A new RF system for a rejuvenated Synchro-cyclotron

    CERN Multimedia

    1975-01-01

    The Synchro-cyclotron is shown here shortly after the completion of the improvement programme, which left the steel magnet yoke as almost the only remaining component of the original machine. On the left can be seen the rotary condenser which produces the frequency modulation required for the acceleration (one of a pair available -in this instance ROTCO II). (see photo 7506015)

  10. Study of microwave components for an electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    Keywords. Microwave system; microwave studio software; network analyser; electron cyclotron resonance ion source. ... of ∼13 eV was obtained. This article describes various aspects of the microwave system including design, fabrication, characterization and performance studies of the microwave components.

  11. Development of beam instruments at JAERI cyclotron facility

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, Susumu; Fukuda, Mitsuhiro; Ishibori, Ikuo; Agematsu, Takashi; Yokota, Watalu; Nara, Takayuki; Nakamura, Yoshiteru; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A beam phase monitor and two kinds of fluence distribution monitors have been developed for measuring characteristics of cyclotron beams. The beam phase monitor provides a beam phase signal for tuning a beam chopping system and a beam phase selection system. A two-dimensional fluence distribution on a large area is measured with fluence distribution monitors. (author)

  12. The electron cyclotron absorption diagnostic at the Rijnhuizen tokamak project

    NARCIS (Netherlands)

    van Gelder, J. F. M.; Miedema, H. S.; Donne, A. J. H.; Oomens, A. A. M.; Schüller, F. C.

    1997-01-01

    A new 20-channel electron cyclotron absorption diagnostic has been developed at the Rijnhuizen tokamak project. It is the first time the electron pressure profile in a tokamak plasma can be measured directly with a time resolution of 1 ms. The diagnostic measures simultaneously the emission and

  13. Electron cyclotron resonance heating in a short cylindrical plasma ...

    Indian Academy of Sciences (India)

    Electron cyclotron resonance (ECR) plasma is produced and studied in a small cylindrical system. Microwave power is delivered by a CW magnetron at 2.45 GHz in TE10 mode and launched radially to have extraordinary (X) wave in plasma. The axial magnetic field required for ECR in the system is such that the first two ...

  14. Unstable Electrostatic Ion Cyclotron Waves Exited by an Ion Beam

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Electrostatic ion cyclotron waves were observed in a quiescent cesium plasma into which a low‐energy beam of sodium ions was injected. The instability appeared when the beam velocity was above 12 times the ion thermal velocity. The waves propagated along the magnetic field with a velocity somewhat...

  15. Cyclotron Resonance of Electrons Trapped in a Microwave Cavity

    Science.gov (United States)

    Elmore, W. C.

    1975-01-01

    Describes an experiment in which the free-electron cyclotron resonance of electrons trapped in a microwave cavity by a Penning trap is observed. The experiment constitutes an attractive alternative to one of the Gardner-Purcell variety. (Author/GS)

  16. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  17. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  18. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 35

    Energy Technology Data Exchange (ETDEWEB)

    1986-10-29

    Efforts are reported on the installation and checkout of cyclotron components which had been previously fabricated. Final integration of subsystems and major systems leading to internal beam tests is reported near completion. Progress is reported in relation to control system components, focus and steering magnet design, and rf system testing. (LEW)

  19. Wave propagation through an electron cyclotron resonance layer

    NARCIS (Netherlands)

    Westerhof, E.

    1997-01-01

    The propagation of a wave beam through an electron cyclotron resonance layer is analysed in two-dimensional slab geometry in order to assess the deviation from cold plasma propagation due to resonant, warm plasma changes in wave dispersion. For quasi-perpendicular propagation, N-parallel to x

  20. Radiation safety aspects of the AGOR superconducting cyclotron facility

    NARCIS (Netherlands)

    Beijers, JPM; de Meijer, RJ

    1996-01-01

    This paper describes shielding calculations and skyshine estimates for the new AGOR K=600 superconducting cyclotron facility. Both simple, semi-empirical models and Monte-Carlo simulations were used. The calculations are based on a 200 MeV proton beam incident on a trick aluminum target. Also the

  1. Electron cyclotron resonance breakdown studies in a linear plasma ...

    Indian Academy of Sciences (India)

    Abstract. Electron cyclotron resonance (ECR) plasma breakdown is studied in a small linear cylindrical system with four different gases – hydrogen, helium, argon and nitrogen. Microwave power in the experimental system is delivered by a magnetron at 2.45 ± 0.02. GHz in TE10 mode and launched radially to have ...

  2. A micropulse monitor for control of cyclotron beams

    Science.gov (United States)

    Lind, D. A.; Peterson, R. J.; Da Silva, A. G.; Auler, L. T.; de Barros, S.

    1990-07-01

    A system using wall current monitors to observe the time structure of the individual beam current pulses of the Cyclotron Corp. CV28 cyclotron installed at the Instituto de Engenharia Nuclear of CNEN in Rio de Janeiro is described. The monitors are designed to give a faithful representation of the actual beam pulse, so the effects on the longitudinal phase space could be seen as the cyclotron parameters were changed. Beam pulses of width in the range of 1 to 4 ns and with a charge of 7 × 10-16 C or greater can be observed. With two units in the line transit times permit beam energy determination as well as charge distribution. For timing purposes a unit placed in front of a target is used to generate a start signal for time-of-flight measurements, and to monitor the effects of all parameters of the cyclotron tune. By measuring flight times in the beamlines of this machine, the energy for 28 MeV protons can be determined to about 50 keV and for the other available particles to about 30 keV.

  3. Study of microwave components for an electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    rious aspects of the microwave system including design, fabrication, characterization and performance studies of the microwave components. Keywords. Microwave system; microwave studio software; network analyser; electron cyclotron resonance ion source. 1. Introduction. Microwave systems at 2.45 GHz have been ...

  4. The development of technology for the improvement of cyclotron performance

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jong Seo; Kim, Y. S.; Ha, J. H.; Lee, M. Y.; Lee, H. S

    1999-05-01

    We show the first-order beam optics theory which is a simplified theory that can be used to carry out the initial design of a cyclotron. Based on this, a computer program has been developed to determine main cyclotron parameters such as number of magnet sectors, sector angle, hill and valley fields, and overall size of the cyclotron etc. We then show the result of two-dimensional magnetic field calculation using POISSON program. By using this program, one can determine magnet yoke geometry and the average magnetic fields etc. Finally, the three-dimensional computer program OPERA-3D had been invoked to determine magnet pole tips (i.e. sector). Validity of the design can be seen by investigating magnetic fields, radial and vertical focusing frequencies as a function of the beam energy. In this report, we show the results of cyclotron magnet design. And we designed 72 MHz RF system and ion source system. We tested RF resonance each coupling methods. We show the result of RF design and prototype operation. Our developed ion source is PIG type. We described our design methods and implementation. We report the result of getting negative hydrogen ion.

  5. Second-harmonic ion cyclotron resonance heating scenarios of ...

    Indian Academy of Sciences (India)

    ... Refresher Courses · Symposia · Live Streaming. Home; Journals; Pramana – Journal of Physics; Volume 85; Issue 4. Second-harmonic ion cyclotron resonance heating scenarios of Aditya tokamak plasma. Asim Kumar Chattopadhyay S V Kulkarni R Srinivasan Aditya Team. Volume 85 Issue 4 October 2015 pp 713-721 ...

  6. Nuclear physics with superconducting cyclotron at Kolkata: Scopes ...

    Indian Academy of Sciences (India)

    At the same time, the nuclear physics programme and related experimental facility development activities are taking shape. A general review of the nuclear physics research opportunities with the superconducting cyclotron and the present status of the development of different detector arrays and other experimental facilities ...

  7. Unstable plasma characteristics in mirror field electron cyclotron ...

    Indian Academy of Sciences (India)

    Electron cyclotron plasma reactor are prone to instabilities in specific input power [3–7] region (150–450 watts). In this region power absorption by gas molecules in the cavity is very poor and enhanced input power gets reflected substantially without increasing ion density. There are abrupt changes in plasma characteristics ...

  8. Application of compact electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Muramatsu, M.; Kitagawa, A.; Iwata, Y.; Ogawa, H.; Hojo, S.; Kubo, T.; Kato, Y.; Biri, S.; Fekete, E.; Yoshida, Y.; Drentje, A. G.

    The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C(4+) ions; its performance such as beam

  9. Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency

    Science.gov (United States)

    Nagornov, Konstantin O.; Kozhinov, Anton N.; Tsybin, Yury O.

    2017-11-01

    Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) at the cyclotron frequency instead of the reduced cyclotron frequency has been experimentally demonstrated using narrow aperture detection electrode (NADEL) ICR cells. Here, based on the results of SIMION simulations, we provide the initial mechanistic insights into the cyclotron frequency regime generation in FT-ICR MS. The reason for cyclotron frequency regime is found to be a new type of a collective motion of ions with a certain dispersion in the initial characteristics, such as pre-excitation ion velocities, in a highly non-quadratic trapping potential as realized in NADEL ICR cells. During ion detection, ions of the same m/z move in phase for cyclotron ion motion but out of phase for magnetron (drift) ion motion destroying signals at the fundamental and high order harmonics that comprise reduced cyclotron frequency components. After an initial magnetron motion period, ion clouds distribute into a novel type of structures - ion slabs, elliptical cylinders, or star-like structures. These structures rotate at the Larmor (half-cyclotron) frequency on a plane orthogonal to the magnetic field, inducing signals at the true cyclotron frequency on each of the narrow aperture detection electrodes. To eliminate the reduced cyclotron frequency peak upon dipolar ion detection, a number of slabs or elliptical cylinders organizing a star-like configuration are formed. In a NADEL ICR cell with quadrupolar ion detection, a single slab or an elliptical cylinder is sufficient to minimize the intensity of the reduced cyclotron frequency components, particularly the second harmonic. [Figure not available: see fulltext.

  10. Summary of EC-17: the 17th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (Deurne, The Netherlands, 7-10 May 2012)

    NARCIS (Netherlands)

    Westerhof, E.; Austin, M. E.; Kubo, S.; Lin-Liu, Y. R.; Plaum, B.

    2013-01-01

    An overview is given of the papers presented at the 17th Joint Workshop on Electron Cyclotron Emission (ECE) and Electron Cyclotron Resonance Heating (ECRH). The meeting covered all aspects of the research field ranging from theory to enabling technologies. From the workshop, advanced control by

  11. Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project

    Energy Technology Data Exchange (ETDEWEB)

    Deng, B.H.; Hsia, R.P.; Domier, C.W.; Burns, S.R.; Hillyer, T.R.; Luhmann, N.C. Jr. [University of California at Davis, 228 Walker Hall, Davis, California 95616 (United States); Oyevaar, T.; Donne, A.J. [FOM-Inst. voor Plasmafysica Rijnhuizen, Association Euratom-FOM (International organizations without location); RTP team

    1999-01-01

    A 16-channel electron cyclotron emission (ECE) imaging diagnostic system has been developed and installed on the Rijnhuizen Tokamak Project for measuring plasma electron cyclotron emission with a temporal resolution of 2 {mu}s. The high spatial resolution of the system is achieved by utilizing a low cost linear mixer/receiver array. Unlike conventional ECE diagnostics, the sample volumes of the ECE imaging system are aligned vertically, and can be shifted across the plasma cross-section by varying the local oscillator frequency, making possible 2D measurements of electron temperature profiles and fluctuations. The poloidal/radial wavenumber spectra and correlation lengths of T{sub e} fluctuations in the plasma core can also be obtained by properly positioning the focal plane of the imaging system. Due to these unique features, ECE imaging is an ideal tool for plasma transport study. Technical details of the system are described, together with preliminary experimental results. {copyright} {ital 1999 American Institute of Physics.}

  12. Studies of radioisotope production with an AVF cyclotron in TIARA

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, Toshiaki [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    The production of radioisotopes to be used mainly for nuclear medicine and biology is studied with an AVF cyclotron in TIARA. A production method of no-carrier-added {sup 186}Re with the {sup 186}W(p,n){sup 186}Re reaction has been developed; this product may be used as a therapeutic agent in radioimmunotherapy due to the adequate nuclear and chemical properties. For the study of the function of plants using a positron-emitter two-dimensional imaging system, a simple method of producing the positron emitter {sup 18}F in water was developed by taking advantage of a highly-energetic {alpha} beam from the AVF cyclotron. (author)

  13. Target development for diversified irradiations at a medical cyclotron.

    Science.gov (United States)

    Spellerberg, S; Scholten, B; Spahn, I; Bolten, W; Holzgreve, M; Coenen, H H; Qaim, S M

    2015-10-01

    The irradiation facility at an old medical cyclotron (Ep=17 MeV; Ed=10 MeV) was upgraded by extending the beam line and incorporation of solid state targetry. Tests performed to check the quality of the available beam are outlined. Results on nuclear data measurements and improvement of radiochemical separations are described. Using solid targets, with the proton beam falling at a slanting angle of 20°, a few radionuclides, e.g. (75)Se, (120)I, (124)I, etc. were produced with medium currents (up to 20 µA) in no-carrier-added form in quantities sufficient for local use. The extended irradiation facility has considerably enhanced the utility of the medical cyclotron. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Neutron spectra due (13)N production in a PET cyclotron.

    Science.gov (United States)

    Benavente, J A; Vega-Carrillo, H R; Lacerda, M A S; Fonseca, T C F; Faria, F P; da Silva, T A

    2015-05-01

    Monte Carlo and experimental methods have been used to characterize the neutron radiation field around PET (Positron Emission Tomography) cyclotrons. In this work, the Monte Carlo code MCNPX was used to estimate the neutron spectra, the neutron fluence rates and the ambient dose equivalent (H*(10)) in seven locations around a PET cyclotron during (13)N production. In order to validate these calculations, H*(10) was measured in three sites and were compared with the calculated doses. All the spectra have two peaks, one above 0.1MeV due to the evaporation neutrons and another in the thermal region due to the room-return effects. Despite the relatively large difference between the measured and calculated H*(10) for one point, the agreement was considered good, compared with that obtained for (18)F production in a previous work. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Physics of electron cyclotron current drive on DIII-D

    CERN Document Server

    Petty, C C; Harvey, R W; Kinsey, J E; Lao, L L; Lohr, J; Luce, T C; Makowski, M A; Prater, R

    2002-01-01

    OAK A271 PHYSICS OF ELECTRON CYCLOTRON CURRENT DRIVE ON DIII-D. Recent experiments on the DIII-D tokamak have focused on determining the effect of trapped particles on the electron cyclotron current drive (ECCD) efficiency. The measured ECCD efficiency increases as the deposition location is moved towards the inboard midplane or towards smaller minor radius for both co and counter injection. The measured ECCD efficiency also increases with increasing electron density and/or temperature. The experimental ECCD is compared to both the linear theory (Toray-GA) as well as a quasilinear Fokker-Planck model (CQL3D). The experimental ECCD is found to be in better agreement with the more complete Fokker-Planck calculation, especially for cases of high rf power density and/or loop voltage. The narrow width of the measured ECCD profile is consistent with only low levels of radial transport for the current carrying electrons.

  16. Ernest Orlando Lawrence (1901-1958), Cyclotron and Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Chu, William T.

    2005-09-01

    On August 8, 2001, Lawrence Berkeley National Laboratory celebrated the centennial of the birth of its founder (and namesake), Ernest Orlando Lawrence. For the occasion, many speeches were given and old speeches were remembered. We recall the words of the late Luis Alvarez, a Nobel Laureate and one of the Lawrence's closest colleagues: ''Lawrence will always be remembered as the inventor of the cyclotron, but more importantly, he should be remembered as the inventor of the modern way of doing science''. J. L. Heilbron and R. W. Seidel, in the introduction of their book, ''Lawrence and His Laboratory'' stated, ''The motives and mechanisms that shaped the growth of the Laboratory helped to force deep changes in the scientific estate and in the wider society. In the entrepreneurship of its founder, Ernest Orlando Lawrence, these motives, mechanisms, and changes came together in a tight focus. He mobilized great and small philanthropists, state and local governments, corporations, and plutocrats, volunteers and virtuosos. The work they supported, from astrophysics and atomic bombs, from radiochemistry to nuclear medicine, shaped the way we observe, control, and manipulate our environment.'' Indeed, all over the civilized world, the ways we do science changed forever after Lawrence built his famed Radiation Laboratory. In this editorial, we epitomize his legacy of changing the way we do medicine, thereby affecting the health and well being of all humanity. This year marks the 75th anniversary of the invention of the cyclotron by Ernest Orlando Lawrence at the University of California at Berkeley. Lawrence conceived the idea of the cyclotron early in 1929 after reading an article by Rolf Wideroe on high-energy accelerators. In the spring of 1930 one of his students, Nels Edlefsen, constructed two crude models of a cyclotron. Later in the fall of the same year, another student, M. Stanley Livingston

  17. Converting an AEG Cyclotron to H- Acceleration and Extraction

    Science.gov (United States)

    Ramsey, Fred; Carroll, Lewis; Rathmann, Tom; Huenges, Ernst; Bechtold, Matthias Mentler Volker

    2009-03-01

    Clinical Trials are under way to evaluate agents labeled with the nuclide 225Ac and its decay product 213Bi, in targeted alpha-immuno-therapy [1]. 225Ac can be produced on a medium-energy cyclotron via the nuclear reaction 226Ra(p,n)225Ac. To demonstrate proof-of-principle, a vintage AEG cyclotron, Model E33 [2], with an internal target, had been employed in a pilot production program at the Technical University of Munich (TUM). To enhance production capability and further support the clinical studies, the TUM facility has recently been refurbished and upgraded, adding a new external beam-line, automated target irradiation and transport systems, new laboratories, hot cells, etc. [3]. An improved high-power rotating target has been built and installed [4]. The AEG cyclotron itself has also been modified and upgraded to accelerate and extract H- ions. We have designed, built, and tested a new axial Penning-type ion source which is optimized for the production of H- ions. The ion source has continued to evolve through experiment and experience. Steady improvements in materials and mechanics have led to enhanced source stability, life-time, and H- production. We have also designed and built a precision H- charge-exchange beam-extraction system which is equipped with a vacuum lock. To fit within the tight mechanical constraint imposed by the narrow magnet gap, the system incorporates a novel chain-drive foil holder and foil-changer mechanism. The reconfigured cyclotron system has now been in operation for more than 1 year. Three long-duration target irradiations have been conducted. The most recent bombardment ran 160 continuous hours at a beam on target of ˜80 microamperes for a total yield of ˜70 milli-curies of 225Ac.

  18. Shielding simulation of the CDTN cyclotron bunker using MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Dalle, Hugo M.; Campolina, Daniel de A.M., E-mail: dallehm@cdtn.b, E-mail: campolina@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Div. de Reatores e Radiacoes

    2011-07-01

    The Nuclear Technology Development Centre (CDTN/CNEN) has contracted services from General Electric in order to install a cyclotron for radioisotopes production and PET radiopharmaceutical synthesis. The Monte Carlo code MCNP5 was used to determine the TVL (tenth value layer) of the concrete and verify shielding calculations performed by GE. The simulations results show values of equivalent dose rates in agreement with those calculated using the methodology adopted by GE, the NCRP-144 and the NCRP-51. (author)

  19. Cyclotron Auto-Resonance Accelerator for environmental applications

    Science.gov (United States)

    Jiang, Yong; Shchelkunov, Sergey V.; Hirshfield, Jay L.

    2017-03-01

    A MW-level CW electron beam source for environmental remediation based on extensions of the scientifically-proven Cyclotron Auto-Resonance Accelerator, dubbed CARA, is described here. CARA is distinguished by its exceptionally high RF-to-beam efficiency, by its production of a self-scanning beam, and by its proportionately lower specific power loading on a beam output window. Its environmental applications include sterilization, flue gas and waste water treatment.

  20. Electron Cyclotron Waves Polarization in the TJII Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cappa, A.; Martinez-Fernandez, J.; Wagner, D.

    2013-05-01

    This report describes the theoretical calculations related with the electron cyclotron (EC) waves polarization control in the TJII stellarator. Two main aspects will be distinguished: the determination of the vacuum polarization that the wave must exhibit if a given propagation mode in a cold plasma is desired and the calculation of the behavior of the grooved polarizers and other transmission systems used to launch the vacuum wave with the required polarization. (Author) 13 refs.

  1. Ion–Cyclotron Resonance Frequency Interval Dependence on the O ...

    Indian Academy of Sciences (India)

    The frequency intervals in which O VI ions get in resonance with ion–cyclotron waves are calculated using the kinetic model, for the latest six values found in literature on O VI ion number densities in the 1.5–3 region of the NPCH. It is found that the common resonance interval is 1.5 kHz to 3 kHz. The -variations of wave ...

  2. Modern compact accelerators of cyclotron type for medical applications

    Science.gov (United States)

    Smirnov, V.; Vorozhtsov, S.

    2016-09-01

    Ion beam therapy and hadron therapy are types of external beam radiotherapy. Recently, the vast majority of patients have been treated with protons and carbon ions. Typically, the types of accelerators used for therapy were cyclotrons and synchrocyclotrons. It is intuitively clear that a compact facility fits best to a hospital environment intended for particle therapy and medical diagnostics. Another criterion for selection of accelerators to be mentioned in this article is application of superconducting technology to the magnetic system design of the facility. Compact isochronous cyclotrons, which accelerate protons in the energy range 9-30 MeV, have been widely used for production of radionuclides. Energy of 230 MeV has become canonical for all proton therapy accelerators. Similar application of a carbon beam requires ion energy of 430 MeV/u. Due to application of superconducting coils the magnetic field in these machines can reach 4-5 T and even 9 T in some cases. Medical cyclotrons with an ironless or nearly ironless magnetic system that have a number of advantages over the classical accelerators are in the development stage. In this work an attempt is made to describe some conceptual and technical features of modern accelerators under consideration. The emphasis is placed on the magnetic and acceleration systems along with the beam extraction unit, which are very important from the point of view of the facility compactness and compliance with the strict medical requirements.

  3. Quench analysis of a novel compact superconducting cyclotron

    Science.gov (United States)

    Ghosh, Sundeep; Dutta Gupta, Anjan; Kanti Dey, Malay; Pal, Gautam

    2017-02-01

    Design and analysis of a compact superconducting cyclotron dedicated for medical applications in the fields of nuclear medicine and therapy is presently being pursued in our organization. The novelty of this cyclotron lies in the fact that it does not consist of any iron-pole. The cyclotron magnet will be made of a set of NbTi coils comprising of solenoid and sector coils which are housed in two halves on either sides of the median plane. The average magnetic field is 1.74 T and the maximum extraction energy is 25 MeV, which is sufficient for production of 99mTc from Mo. In this paper, quench analyses of the coils have been discussed in details considering adiabatic condition. The entire cryostat magnet along with coils, formers and support links were modelled for the quench simulation. Self and mutual inductances of all the coils were obtained from a separate magnetic analysis and used in the simulation. Parametric analyses were carried out with different quench initiation energy at various critical locations on the coil surface. The corresponding quench behaviour, i.e. maximum temperature rise, maximum voltage and current decay in each of the coils have been studied.

  4. A Suzaku View of Cyclotron Line Sources and Candidates

    Science.gov (United States)

    Pottschmidt, K.; Suchy, S.; Rivers, E.; Rothschild, R. E.; Marcu, D. M.; Barragan, L.; Kuehnel, M.; Fuerst, F.; Schwarm, F.; Kreykenbohm, I.; hide

    2012-01-01

    Seventeen accreting neutron star pulsars, mostly high mass X-ray binaries with half of them Be-type transients, are known to exhibit Cyclotron Resonance Scattering Features (CRSFs) in their X-ray spectra, with characteristic line energies from 10 to 60 keY. To date about two thirds of them, plus a few similar systems without known CRSFs, have been observed with Suzaku. We present an overview of results from these observations, including the discovery of a CRSF in the transient IA1118-61 and pulse phase resolved spectroscopy of OX 301-2. These observations allow for the determination of cyclotron line parameters to an unprecedented degree of accuracy within a moderate amount of observing time. This is important since these parameters vary - e.g., with orbital phase, pulse phase, or luminosity - depending on the geometry of the magnetic field of the pulsar and the properties of the accretion column at the magnetic poles. We briefly introduce a spectral model for CRSFs that is currently being developed and that for the first time is based on these physical properties. In addition to cyclotron line measurements, selected highlights from the Suzaku analyses include dip and flare studies, e.g., of 4U 1907+09 and Vela X-I, which show clumpy wind effects (like partial absorption and/or a decrease in the mass accretion rate supplied by the wind) and may also display magnetospheric gating effects.

  5. Emittance Measurement for Beamline Extension at the PET Cyclotron

    Directory of Open Access Journals (Sweden)

    Sae-Hoon Park

    2016-01-01

    Full Text Available Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV, which can be obtained from high-energy (of tens MeV accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper.

  6. The cyclotron laboratory and the RFQ accelerator in Bern

    Science.gov (United States)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Scampoli, P.; von Bremen, K.; Weber, M.

    2013-07-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  7. The cyclotron laboratory and the RFQ accelerator in Bern

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Scampoli, P. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland and Department of Physical Sciences, University Federico II, Via Cintia, I-60126 Napoli (Italy); Bremen, K. von [SWAN Isotopen AG, Inselspital, CH-3010 Bern (Switzerland)

    2013-07-18

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  8. PRODUCTION OF 11 C-METHIONINE BY CYCLOTRON AVF JAERI

    Directory of Open Access Journals (Sweden)

    Sri Hastini

    2010-06-01

    Full Text Available At the Takasaki-site of JAERI, an AVF cyclotron has been constructed for advanced radiation technology research. The cyclotron produces extracted beams particularly light and heavy ions of proton as well as deutron. Target chamber is available for production of 11CO2 a positron emitter radioisotope, by bombardment of proton from nitrogen gas as a target, by 14 N (p,a 11C reaction. The use of incident energy on target was estimated to be 11 MeV for primary proton energy of 20 MeV and the beam current was 0,1 m A and the irradiation time was 10 minutes for production of 11CO2 and the yield was about 30 MBq (EOBand for irradiation time 15 minutes and the beam current was 1 mA for production of 11C-Methionine, the yield was about 70 MBq (EOB. Remotely operated automatic and semiautomatic processing systems are used for the production of the 11 C-Methionine agent and the radiochemical purity of the product obtained was determined by High Performance Liquid Chromatography (HPLC with cation exchange column was LC 10 AD MERCK LICHROSPHER 100 RP-18 and the mobile phase was 10 mM ammonium phormmate, the mean of retention time was 1,815 minutes and the radiochemical purity to be more than 90 %. The product was used for plant studies and visualized by PETIS (Positron Emission Tracer Imaging System   Keywords: cyclotron, Positron emitter, 11C-Methionine.

  9. EURAC: A liquid target neutron spallation source using cyclotron technology

    Science.gov (United States)

    Perlado, J. M.; Mínguez, E.; Sanz, J.; Piera, M.

    1995-09-01

    Euratom/JRC Ispra led some years ago the design of an accelerator based neutron spallation source EURAC, with special emphasis as a fusion material testing device. DENIM was involved in the development of the last version of this source. EURAC proposes to use a beam of 600 MeV or 1.5 GeV protons, produced by an effective and low cost ring cyclotron with a current of 6 mA impinging in a liquid lead, or lead-bismuth, target. It will use an advanced cyclotron technology which can be implemented in the next future, in the line of the actual technology of the upgraded SIN-type cyclotron. The adjacent rows to the target correspond to the lead, or Li17Pb83, cooled channels where the samples will be located. The available volumes there were shown enough for material testing purposes. Here, proposal of using those experimental areas to introduce small masses of radioactive wastes for testing of transmutation in spallation source is made. In addition, extrapolation of present conceptual design to make available larger volumes under flexible conditions seems to be possible. Neutrons leaking from the test zone drive a subcritical booster (hidrogen moderator in the center.

  10. Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron.

    Science.gov (United States)

    Hojo, S; Katagiri, K; Nakao, M; Sugiura, A; Muramatsu, M; Noda, A; Okada, T; Takahashi, Y; Komiyama, A; Honma, T; Noda, K

    2014-02-01

    The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C(4+) ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8-10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C(4+), for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

  11. Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron

    Science.gov (United States)

    Hojo, S.; Katagiri, K.; Nakao, M.; Sugiura, A.; Muramatsu, M.; Noda, A.; Okada, T.; Takahashi, Y.; Komiyama, A.; Honma, T.; Noda, K.

    2014-02-01

    The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C4+ ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8-10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C4+, for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

  12. Static harmonization of dynamically harmonized Fourier transform ion cyclotron resonance cell.

    Science.gov (United States)

    Zhdanova, Ekaterina; Kostyukevich, Yury; Nikolaev, Eugene

    2017-08-01

    Static harmonization in the Fourier transform ion cyclotron resonance cell improves the resolving power of the cell and prevents dephasing of the ion cloud in the case of any trajectory of the charged particle, not necessarily axisymmetric cyclotron (as opposed to dynamic harmonization). We reveal that the Fourier transform ion cyclotron resonance cell with dynamic harmonization (paracell) is proved to be statically harmonized. The volume of the statically harmonized potential distribution increases with an increase in the number of trap segments.

  13. Magnetic Cyclotron Waves near the Proton Cyclotron Frequency in the Solar Wind: Wind and ACE Observations in 2005

    Science.gov (United States)

    Broiles, T. W.; Jian, L.; Stevens, M. L.; Gary, S. P.; Lepri, S. T.; Vinas, A. F.; Moya, P. S.; Alexander, R.

    2016-12-01

    Strong narrow-band electromagnetic waves near the proton cyclotron frequency (fpc) have been observed extensively in the solar wind throughout the inner heliosphere. They are transverse and near-circularly polarized, and propagate in directions quasi-parallel or anti-parallel to the magnetic field. Their frequency is a few times of fpc in the spacecraft frame and a fraction of fpc in the plasma frame after removing the Doppler shift effect. These waves are left-hand (LH) or right-hand (RH) polarized in the spacecraft frame with otherwise similar characteristics except LH ones appear more often and have higher wave power. Intrinsically they can be LH polarized Alfven-cyclotron waves or RH polarized magnetosonic waves. Through the assistance of audification, we have studied the long-lasting wave events near fpc in 2005 using the high-cadence magnetic field data and well-calibrated plasma data from the Wind mission. A mixture of temperature anisotropies for core protons, beam protons, and alpha particles, as well as proton beam drift are often found for selected events of extensive waves. The wave dispersion analysis using these ion moments indicate these waves are likely to be associated with unstable Alfven-cyclotron anisotropy instability or ion beam instability, and suggest there is a mixture of Alfven-cyclotron waves and magnetosonic waves in the solar wind. Using the conjunction of Wind and ACE spacecraft when they were within 50 Earth radii of each other, we study how often the two spacecraft observe the same waves and whether there is noticeable heating for heavy ions associated with these waves.

  14. Monte Carlo simulation of cyclotron resonant scattering features

    Science.gov (United States)

    Schwarm, Fritz-Walter; Schönherr, Gabriele; Wilms, Joern

    In the regime of very high magnetic fields on the order of 10(12} mathrm{G) the electron momenta perpendicular to the field are quantized due to the discrete Landau levels populated by the electrons. Parallel to the magnetic field the electrons form a continuous momentum distribution. The seed photon continuum is generated for example by bremsstrahlung or blackbody radiation. Resonant scattering of a seed photon by an electron may excite the electron to a higher Landau level. The subsequent de-excitation of the excited electron produces additional photons close to the resonance energy. This way complex cyclotron resonant scattering features (CRSFs) are imprinted on the continuum radiation. Due to the continuous electron momentum distribution parallel to the magnetic field the scattering photon's energy and angle are mixed by Lorentz transformation to the electron rest frame in which the resonant scattering process is being carried out. Therefore synthetic spectra of cyclotron lines can not be accurately calculated analytically. CRSFs have been observed in more than a dozen accreting X-ray binaries. They provide much information about the accretion structure in the observed systems since the exact line shape is sensitive to many parameters in the column. Typical parameters are for example the geometry and the spectral properties of seed photon sources, the geometry of the column, or the magnetic field and temperature within the column. We present an overview over the Monte-Carlo approach to cyclotron line simulation and show results from our texttt{cyclosim} code. Furthermore we investigate the influence of the accretion geometry on the cyclotron line shape. Our code enables us to perform fully relativistic simulations including the correct cyclotron scattering cross sections and the possibility to cope with parameter gradients such as magnetic field, temperature, or velocity gradients within the accretion column. Using a Green's function approach these simulations

  15. Electromagnetic Cyclotron Waves in the Solar Wind: Wind Observation and Wave Dispersion Analysis

    Science.gov (United States)

    Jian, L. K.; Moya, P. S.; Vinas, A. F.; Stevens, M.

    2016-01-01

    Wind observed long-lasting electromagnetic cyclotron waves near the proton cyclotron frequency on 11 March 2005, in the descending part of a fast wind stream. Bi-Maxwellian velocity distributions are fitted for core protons, beam protons, and alpha-particles. Using the fitted plasma parameters we conduct kinetic linear dispersion analysis and find ion cyclotron and/or firehose instabilities grow in six of 10 wave intervals. After Doppler shift, some of the waves have frequency and polarization consistent with observation, thus may be correspondence to the cyclotron waves observed.

  16. Comparison of neutron fluxes in an 18-MeV unshielded cyclotron room and a 16.5-MeV self-shielded cyclotron room.

    Science.gov (United States)

    Fujibuchi, Toshioh; Horitsugi, Genki; Yamaguchi, Ichiro; Eto, Akihisa; Iwamoto, Yasuo; Obara, Satoshi; Iimori, Takashi; Masuda, Yoshitada; Watanabe, Hiroshi; Hatazawa, Jun

    2012-07-01

    Some medical compact cyclotrons have self-shielding to reduce neutron fluxes. Thermal neutron fluxes in an 18-MeV unshielded cyclotron room and in a 16.5-MeV self-shielded cyclotron room were evaluated. In addition, the radioactivities in concrete and metals due to thermal neutrons in the cyclotron rooms for 30 years were calculated of operation such that the sum of the ratio of the nuclide concentration to the nuclide clearance level was equal to 1. The thermal neutron flux from the unshielded cyclotron was approximately 10(2) cm(-2) s(-1), whereas that from the self-shielded cyclotron was approximately 10(2) cm(-2) s(-1). The thermal neutron fluxes for concrete, stainless steel, vessel steel, and aluminum that reached their clearance levels were 9.80 × 10(4), 2.17 × 10(3), 1.87 × 10(4), and 2.41 × 10(5) cm(-2) s(-1), respectively. The specific activities in the cyclotron room were found to be sufficiently below the clearance level when the self-shield was employed.

  17. Practical experience and challenges in the operation of medical cyclotron.

    Science.gov (United States)

    Kumar, Rajeev; Sonkawade, Rajendra G; Pandey, Anil K; Tripathi, Madhavi; Damle, Nishikant A; Kumar, Praveen; Bal, Chandra S

    2017-01-01

    The aim of this article was to share 10 years of operational experience of medical cyclotron and to provide working knowledge on the same. This experience has helped us gain working knowledge on cyclotron operation with practical points, which may help in improving F yield, minimizing the breakdown time, and help in the prevention of the occurrence of unusual events. Our facility has a self-shielded radioisotope delivery system eclipse 111 medical cyclotron with an 11 MeV proton beam in use for the past 10 years to produce positron emitters - namely, F, N, and F-2 gas - for PET imaging. During F production, we have followed a set protocol comprising the following: monitoring target pressure, rinsing the target with O water just immediately after bombardment, ion source feedback, radiofrequency (RF) feedback, and recording any unusual events that occurred during the operation. Besides this, enrichment of O water, target volume, target current, energy of the beam, variation in argon pressure on the target, bombardment duration, target status (new or old target or total number of previous bombardments on the same target), status of the delivery lines from target to the radiochemistry module (old or new) were also recorded. Rinsing with O water immediately after bombardment increases the life of the target and delivery line. The frequent problems encountered were with the ion source, RF, and target foil rupture. These problems were solved by rebuilding the ion source, changing the fuse of RF, and rebuilding the target. F yield can be increased by rinsing with O water immediately after bombardment. The effect of target leak - that is, rupture of vacuum window - can be avoided by immediate stoppage of bombardment.

  18. Electromagnetic waves near the proton cyclotron frequency: Stereo observations

    Energy Technology Data Exchange (ETDEWEB)

    Jian, L. K. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Wei, H. Y.; Russell, C. T. [Institute of Geophysics and Planetary Physics, University of California, Los Angeles, CA 90095 (United States); Luhmann, J. G. [Space Science Laboratory, University of California, Berkeley, CA 94720 (United States); Klecker, B. [Max-Planck-Institut für Extraterrestrische Physik, D-85741 Garching (Germany); Omidi, N. [Solana Scientific Inc., Solana Beach, CA 92075 (United States); Isenberg, P. A. [Institute for the Study of Earth, Oceans, and Space, University of New Hampshire, Durham, NH 03824 (United States); Goldstein, M. L.; Figueroa-Viñas, A. [Heliophysics Science Division, NASA Goddard Space Flight Center, MD 20771 (United States); Blanco-Cano, X., E-mail: lan.jian@nasa.gov [Instituto de Geofisica, Universidad Nacional Autónoma de México, Coyoacán D.F. (Mexico)

    2014-05-10

    Transverse, near-circularly polarized, parallel-propagating electromagnetic waves around the proton cyclotron frequency were found sporadically in the solar wind throughout the inner heliosphere. They could play an important role in heating and accelerating the solar wind. These low-frequency waves (LFWs) are intermittent but often occur in prolonged bursts lasting over 10 minutes, named 'LFW storms'. Through a comprehensive survey of them from Solar Terrestrial Relations Observatory A using dynamic spectral wave analysis, we have identified 241 LFW storms in 2008, present 0.9% of the time. They are left-hand (LH) or right-hand (RH) polarized in the spacecraft frame with similar characteristics, probably due to Doppler shift of the same type of waves or waves of intrinsically different polarities. In rare cases, the opposite polarities are observed closely in time or even simultaneously. Having ruled out interplanetary coronal mass ejections, shocks, energetic particles, comets, planets, and interstellar ions as LFW sources, we discuss the remaining generation scenarios: LH ion cyclotron instability driven by greater perpendicular temperature than parallel temperature or by ring-beam distribution, and RH ion fire hose instability driven by inverse temperature anisotropy or by cool ion beams. The investigation of solar wind conditions is compromised by the bias of the one-dimensional Maxwellian fit used for plasma data calibration. However, the LFW storms are preferentially detected in rarefaction regions following fast winds and when the magnetic field is radial. This preference may be related to the ion cyclotron anisotropy instability in fast wind and the minimum in damping along the radial field.

  19. Cyclotron facilities in Brazil: Current status and licensing aspects

    Energy Technology Data Exchange (ETDEWEB)

    Facure, A.; Carvalho, S.M.; Di Prinzio, R.; Silveira, C.S.; Gasparian, P.B.R.; Franca, W.F., E-mail: facure@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-09-01

    Positron Emission Tomography (PET) is a highly sensitive and accurate nuclear medicine imaging technology but the major problem of this technique is the use of radioisotopes with short half-life, less than two hours. The production and selling of short half-life radioisotopes used to be monopoly of the Brazilian Government. In 2006, a Constitutional Amendment revoked the state monopoly due to the need for the use of short half-life radioisotopes in nuclear medicine centers very far from the government production facilities. The aim of this study is to describe the current status of short half-life radioisotopes production in Brazil and discuss some licensing process. In Brazil, as has been occurring worldwide, the number of nuclear medicine centers is increasing. Currently there are 123 services performing PET scans in Brazil. There are 14 cyclotrons operating in Brazil. The type of licensing process conducted in Brazil does not take into account the population density of each state, with a free competition model being adopted. Because of this there is a lot of equipment concentrated in the Southeast and no cyclotrons operating in the Northern part of the country. One of the biggest obstacles during the licensing process is the designation of qualified personnel as operation workers and radiation safety officers. The number of cyclotron accelerators and PET/CT equipment increased in recent years. However, a number of external factors such as the distance from the nuclear medicine centers, and qualified personnel have proved crucial for the economic viability of this type of facility. (author)

  20. Glow plasma trigger for electron cyclotron resonance ion sources.

    Science.gov (United States)

    Vodopianov, A V; Golubev, S V; Izotov, I V; Nikolaev, A G; Oks, E M; Savkin, K P; Yushkov, G Yu

    2010-02-01

    Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 micros and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10(12) cm(-3), required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T(e) approximately = 20 eV.

  1. Experimental monitoring of ozone production in a PET cyclotron facility

    Energy Technology Data Exchange (ETDEWEB)

    Zanibellato, L. [Department of Energetic, Nuclear and Environmental Control, University of Bologna (Italy); Cicoria, G.; Pancaldi, D. [Department of Medical Physics, University Hospital ' S.Orsola-Malpighi' , Bologna (Italy); Boschi, S. [PET Radiopharmacy Unit, Department of Nuclear Medicine, University Hospital ' S.Orsola-Malpighi' , Bologna (Italy); Mostacci, D. [Department of Energetic, Nuclear and Environmental Control, University of Bologna (Italy); Marengo, M., E-mail: marengo@med.unibo.i [Department of Medical Physics, University Hospital ' S.Orsola-Malpighi' , Bologna (Italy)

    2010-10-15

    Ozone produced from radiolytic processes was investigated as a possible health hazard in the working environment at the University Hospital 'S.Orsola-Malpighi' PET facility. Intense radiation fields can generate ozone, known to be the most toxic gas produced by ionizing radiation around a particle accelerator. To evaluate ozone concentration in air, two different measurement campaigns were conducted with passive diffusion detectors. Comparison of the results with the concentration limits recommended by American Conference of Governmental Industrial Hygienists (ACGIH) demonstrated that ozone poses no health hazard to workers around a biomedical cyclotron.

  2. A new EMIS facility at the Tohoku University cyclotron

    Science.gov (United States)

    Fujioka, M.; Shinozuka, T.; Tanaka, E.; Arai, Y.; Hayashibe, S.; Ishimatsu, T.

    1981-07-01

    An EMIS facility has begun operation at one of the beam lines of a multipurpose cyclotron of K = 50 MeV. The separator is of a Scandinavian type of 55° deflection and 1500 mm dispersion, and is equipped with three beam-transport lines to which are connected a tape-transport system for ISOL study, a retardation system for implantation work and an optical spectrometer for surface analysis. The status and developments of this facility are reported here for the first time.

  3. Coaxial ring cyclotron as a perspective nuclear power engineering machine

    CERN Document Server

    Tumanyan, A R; Mkrtchyan, R L; Amatuni, T A; Avakian, R O; Khudaverdian, A G

    1995-01-01

    Coaxial Ring Cyclotron (CRC) is described, and its main advantages, such as simple injection technique, several injected beams summation option, high efficiency, are considered. The proposed proton accelerator is a perspective machine for the solution of the main problems of the present day nuclear power engineering as well as for the next-generation nuclear power plants, representing a combination of subcritical reactors and particle accelerators. The possibility of installation of CRCs into ring accelerators with an average diameter from 60 to 100m, e.g., the Yerevan electron synchrotron, is considered.

  4. Spot-welding solid targets for high current cyclotron irradiation

    Science.gov (United States)

    Ellison, Paul A.; Valdovinos, Hector F.; Graves, Stephen A.; Barnhart, Todd E.; Nickles, Robert J.

    2016-01-01

    Zirconium-89 finds broad application for use in positron emission tomography. Its cyclotron production has been limited by the heat transfer from yttrium targets at high beam currents. A spot welding technique allows a three-fold increase in beam current, without affecting 89Zr quality. An yttrium foil, welded to a jet-cooled tantalum support base accommodates a 50 μA proton beam degraded to 14 MeV. The resulting activity yield of 48 ± 4 MBq/(μA·hr) now extends the outreach of 89Zr for a broader distribution. PMID:27771445

  5. Calibration of electron cyclotron emission radiometer for KSTAR.

    Science.gov (United States)

    Kogi, Y; Jeong, S H; Lee, K D; Akaki, K; Mase, A; Kuwahara, D; Yoshinaga, T; Nagayama, Y; Kwon, M; Kawahata, K

    2010-10-01

    We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV.

  6. Ion cyclotron resonance heating system in the RT-1 magnetospheric plasma

    Science.gov (United States)

    Nishiura, M.; Kawazura, Y.; Yoshida, Z.; Kenmochi, N.; Yano, Y.; Saitoh, H.; Yamasaki, M.; Mushiake, T.; Kashyap, A.; Takahashi, N.; Nakatsuka, M.; Fukuyama, A.

    2017-08-01

    We have developed an ion cyclotron resonance frequency (ICRF) heating system for the Ring Trap 1 (RT-1) magnetospheric device. We excite slow waves from the polar region of the dipole magnetic field. The target helium plasma is produced by electron cyclotron heating. The electrons comprise high-temperature (>10 keV) and low-temperature (wave electric field in the plasma.

  7. Quantum oscillation of the cyclotron mass in two-dimensional electron systems in silicon

    NARCIS (Netherlands)

    Kaesen, K.F.; Huber, A; Lorenz, H.; Kotthaus, J.P.; Bakker, S.; Klapwijk, T.M

    1996-01-01

    The cyclotron resonance of two-dimensional electron systems in silicon metal-oxide-semiconductor devices is investigated for high electron densities in high magnetic fields. The cyclotron mass, extracted from the resonance frequency, shows an oscillatory behavior. The periodicity of this oscillation

  8. Periodic Beam Current Oscillations Driven by Electron Cyclotron Instabilities in ECRIS Plasmas

    OpenAIRE

    Tarvainen, Olli; Kalvas, Taneli; Koivisto, Hannu; Komppula, Jani; Kronholm, Risto; Laulainen, Janne; Izotov, I.; Mansfeld, D.; Skalyga, V.; Toivanen, V.

    2014-01-01

    Experimental observation of cyclotron instabilities in electron cyclotron resonance ion source plasma operated in cwmode is reported. The instabilities are associated with strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents. The instabilities are shown to restrict the parameter space available for the optimization of high charge state ion currents.

  9. Effect of ion clouds micromotion on measured signal in Fourier transform ion cyclotron resonance: Computer simulation.

    Science.gov (United States)

    Vladimirov, Gleb; Kostyukevich, Yury; Kharybin, Oleg; Nikolaev, Eugene

    2017-08-01

    Particle-in-cell-based realistic simulation of Fourier transform ion cyclotron resonance experiments could be used to generate ion trajectories and a signal induced on the detection electrodes. It has been shown recently that there is a modulation of "reduced" cyclotron frequencies in ion cyclotron resonance signal caused by Coulomb interaction of ion clouds. In this work it was proposed to use this modulation in order to determine frequency difference between an ion of known m/z and all other ions generating signal in ion cyclotron resonance cell. It is shown that with an increase of number of ions in ion cyclotron resonance trap, the modulation index increases, which lead to a decrease in the accuracy of determination of peak intensities by super Fourier transform resolution methods such as filter diagonalization method.

  10. Reduction of axial kinetic energy induced perturbations on observed cyclotron frequency.

    Science.gov (United States)

    Kaiser, Nathan K; Weisbrod, Chad R; Webb, Brian N; Bruce, James E

    2008-04-01

    With Fourier transform ion cyclotron resonance (FTICR) mass spectrometry one determines the mass-to-charge ratio of an ion by measuring its cyclotron frequency. However, the need to confine ions to the trapping region of the ion cyclotron resonance (ICR) cell with electric fields induces deviations from the unperturbed cyclotron frequency. Additional perturbations to the observed cyclotron frequency are often attributed to changes in space charge conditions. This study presents a detailed investigation of the observed ion cyclotron frequency as a function of ion z-axis kinetic energy. In a perfect three-dimensional quadrupolar field, cyclotron frequency is independent of position within the trap. However, in most ICR cell designs, this ideality is approximated only near the trap center and deviations arise from this ideal quadrupolar field as the ion moves both radially and axially from the center of the trap. To allow differentiation between deviations in observed cyclotron frequency caused from changes in space charge conditions or differences in oscillation amplitude, ions with identical molecular weights but different axial kinetic energy, and thus amplitude of z-axis motion, were simultaneously trapped within the ICR cell. This allows one to attribute deviations in observed cyclotron frequency to differences in the average force from the radial electric field experienced by ions of different axial amplitude. Experimentally derived magnetron frequency is compared with the magnetron frequency calculated using SIMION 7.0 for ions of different axial amplitude. Electron promoted ion coherence, or EPIC, is used to reduce the differences in radial electric fields at different axial positions. Thus with the application of EPIC, the differences in observed cyclotron frequencies are minimized for ions of different axial oscillation amplitudes.

  11. Survey of Saturn electrostatic cyclotron harmonic wave intensity

    Science.gov (United States)

    Menietti, J. D.; Averkamp, T. F.; Kurth, W. S.; Ye, S.-Y.; Gurnett, D. A.; Cecconi, B.

    2017-08-01

    We conduct a survey of electrostatic electron cyclotron harmonic (ECH) emissions observed at Saturn by the radio and plasma wave science investigation on board the Cassini spacecraft. These emissions are known to be effective at interacting with electrons in the terrestrial inner magnetosphere, producing electron scattering into the loss cone and acceleration (cf. Horne and Thorne, 2000; Thorne et al., 2010). At Saturn ECH emission occurs with high probability and at strong intensity near the magnetic equator, outside the Enceladus torus in the range 5 < L < 10. Inside the inner boundary of the torus, ECH emissions are also observed near the equator and at higher latitude. Intensity levels of ECH emission are comparable to those observed at Earth, higher than Saturn chorus and Z-mode emission, and are likely to scatter electrons into the loss cone as at Earth. ECH waves are particularly intense and extend to higher harmonics within some plasma injection regions. We present results for a survey of over 8 years of Saturn data for fundamental and up to three harmonics of fce, the electron cyclotron frequency.

  12. New radionuclides production on the isochronous cyclotron U-120M

    Energy Technology Data Exchange (ETDEWEB)

    Stursa, J.; Cihak, M.; Krivanek, M.; Kucera, J.; Lacman, J. [Nuclear Physics Institute, Prague (Czech Republic)

    1999-07-01

    The production of {sup 18}F for positron emission tomography (PET) applications and manufacturing of the {sup 81}Rb for the {sup 81}Rb/{sup 81m}Kr radionuclidic generator (used in lung ventilation studies) have been introduced as a new program of the twenty year old cyclotron U-120M(K=40, A/Z=1-2.8). The cyclotron conversion from positive to H/{sup -}D{sup -} accelerating regimes and the extraction by means of stripping were necessary for obtaining sufficiently high beam intensities. Two possible solutions of H{sup -} gain - either from the external high intensive (1 mA DC) old TRIUMF CUSP ion source or from the internal ion source with a cold cathode developed in our laboratory - are described. Axial injector characteristics for H{sup -} currents up to 1 mA together with optimizing the central region, the ion extraction system and upgrade of the vacuum system are presented. The realization of the enriched H{sub 2}O{sup 18} target, its setting into operation and the first results of {sup 18}F production (average yields {approx} 2 GBq/{mu}A. hour at EOB) are briefly discussed. (authors)

  13. A study of nosocomial diarrhea in Calcutta.

    Science.gov (United States)

    Das, A S; Mazumder, D N; Pal, D; Chattopadhyay, U K

    1996-01-01

    Nosocomial infection is a major problem in hospitalized patients, particularly those who are debilitated. These infections may manifest as diarrhea. The spectrum of infections agents causing nosocomial diarrhea in our country is not known. Thirty-two patients, admitted to the hospital with various complaints, who developed diarrhea during their hospital stay, were studied to identify the causative agents of diarrhea. Hospital food samples were also processed for pathogens. The bacteria isolated from patients included established enteropathogens like Salmonella, enteropathogenic Escherichia coli, Campylobacter species and organisms with low pathogenicity like Serratia marsescens, Pseudomonas aeruginosa and Morganella morganii. The bacterial pathogens isolated were resistant to most antibiotics, suggesting their nosocomial character. Hospital food samples contained Salmonella typhimurium, Campylobacter jejuni (biotype 1) and enteropathogenic Escherichia coli, suggesting that food might have been the vehicle for these infections. Nosocomial infection was found to be an important cause of diarrhea (34%), EPEC and Salmonell being the predominant pathogens. Water, egg and milk were the source of infection in these cases. Special measures to obtain uneffected items will prevent occurrence of nosocomial diarrhea in our hospitals.

  14. Cyclotrons with fast variable and/or multiple energy extraction

    Directory of Open Access Journals (Sweden)

    C. Baumgarten

    2013-10-01

    Full Text Available We discuss the possibility in principle of stripping extraction in combination with reverse bends in isochronous separate-sector cyclotrons (and/or fixed field alternating gradient accelerators. If one uses reverse bends between the sectors (instead of or in combination with drifts and places stripper foils at the sector exit edges, the stripped beam has a reduced bending radius and it should be able to leave the cyclotron within the range of the valley—even if the beam is stripped at less than full energy. We are especially interested in stripping of H_{2}^{+}, as it doubles the charge to mass ratio of the ions. However the method could be applied to other ions or ionized molecules as well. For the production of proton beams by stripping extraction of an H_{2}^{+} beam, we discuss possible designs for three types of machines: First, a low-energy cyclotron for the simultaneous production of several beams at multiple energies—for instance 15, 30, and 70 MeV—thus allowing beam delivery on several isotope production targets. In this case it can be an advantage to have a strong energy dependence of the direction of the extracted beam. Second, we consider a fast variable-energy proton machine for cancer therapy that should allow extraction (of the complete beam at all energies in the range of about 70 MeV to about 250 MeV into the same beam line. Third, we consider a high-intensity high-energy machine, where the main design goals are extraction with low losses, low activation of components, and high reliability. Especially if such a machine is considered for an accelerator driven system (ADS, this extraction mechanism has advantages: Beam trips by the failure of electrostatic elements could be avoided and the turn separation would be less critical, which allows operation at lower main cavity voltages. This would in turn reduce the number of rf trips. The price that has to be paid for these advantages is an increase in size and/or field

  15. Technical note: building a combined cyclotron and MRI facility: implications for interference.

    Science.gov (United States)

    Hofman, Mark B M; Kuijer, Joost P A; de Ridder, Jan Willem; Perk, Lars R; Verdaasdonk, Rudolf M

    2013-01-01

    With the introduction of hybrid PET∕MRI systems, it has become more likely that the cyclotron and MRI systems will be located close to each other. This study considered the interference between a cyclotron and a superconducting MRI system. Interactions between cyclotrons and MRIs are theoretically considered. The main interference is expected to be the perturbation of the magnetic field in the MRI due to switching on or off the magnetic field of the cyclotron. MR imaging is distorted by a dynamic spatial gradient of an external inplane magnetic field larger than 0.5-0.04 μT∕m, depending on the specific MR application. From the design of a cyclotron, it is expected that the magnetic fringe field at large distances behaves as a magnetic dipolar field. This allows estimation of the full dipolar field and its spatial gradients from a single measurement. Around an 18 MeV cyclotron (Cyclone, IBA), magnetic field measurements were performed on 5 locations and compared with calculations based upon a dipolar field model. At the measurement locations the estimated and measured values of the magnetic field component and its spatial gradients of the inplane component were compared, and found to agree within a factor 1.1 for the magnetic field and within a factor of 1.5 for the spatial gradients of the field. In the specific case of the 18 MeV cyclotron with a vertical magnetic field and a 3T superconducting whole body MR system, a minimum distance of 20 m has to be considered to prevent interference. This study showed that a dipole model is sufficiently accurate to predict the interference of a cyclotron on a MRI scanner, for site planning purposes. The cyclotron and a whole body MRI system considered in this study need to be placed more than 20 m apart, or magnetic shielding should be utilized.

  16. Technical Note: Building a combined cyclotron and MRI facility: Implications for interference

    Energy Technology Data Exchange (ETDEWEB)

    Hofman, Mark B. M.; Kuijer, Joost P. A.; Ridder, Jan Willem de; Perk, Lars R.; Verdaasdonk, Rudolf M. [Physics and Medical Technology, VU University Medical Center, Amsterdam 1007 MB (Netherlands) and BV Cyclotron VU, Amsterdam 1081HV (Netherlands)

    2013-01-15

    Purpose: With the introduction of hybrid PET/MRI systems, it has become more likely that the cyclotron and MRI systems will be located close to each other. This study considered the interference between a cyclotron and a superconducting MRI system. Methods: Interactions between cyclotrons and MRIs are theoretically considered. The main interference is expected to be the perturbation of the magnetic field in the MRI due to switching on or off the magnetic field of the cyclotron. MR imaging is distorted by a dynamic spatial gradient of an external inplane magnetic field larger than 0.5-0.04 {mu}T/m, depending on the specific MR application. From the design of a cyclotron, it is expected that the magnetic fringe field at large distances behaves as a magnetic dipolar field. This allows estimation of the full dipolar field and its spatial gradients from a single measurement. Around an 18 MeV cyclotron (Cyclone, IBA), magnetic field measurements were performed on 5 locations and compared with calculations based upon a dipolar field model. Results: At the measurement locations the estimated and measured values of the magnetic field component and its spatial gradients of the inplane component were compared, and found to agree within a factor 1.1 for the magnetic field and within a factor of 1.5 for the spatial gradients of the field. In the specific case of the 18 MeV cyclotron with a vertical magnetic field and a 3T superconducting whole body MR system, a minimum distance of 20 m has to be considered to prevent interference. Conclusions: This study showed that a dipole model is sufficiently accurate to predict the interference of a cyclotron on a MRI scanner, for site planning purposes. The cyclotron and a whole body MRI system considered in this study need to be placed more than 20 m apart, or magnetic shielding should be utilized.

  17. Experiments on ion cyclotron damping at the deuterium fourth harmonic in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Pinsker, R.I.; Petty, C.C. [General Atomics, San Diego, CA (United States); Baity, F.W. [Oak Ridge National Lab., TN (United States); Bernabei, S.; Greenough, N. [Princeton Plasma Physics Lab., NJ (United States); Heidbrink, W.W. [Univ. of California, Irvine, CA (United States); Mau, T.K. [Univ. of California, San Diego, CA (United States); Porkolab, M. [Massachusetts Inst. of Tech., Cambridge, MA (United States)

    1999-05-01

    Absorption of fast Alfven waves by the energetic ions of an injected beam is evaluated in the DIII-D tokamak. Ion cyclotron resonance absorption at the fourth harmonic of the deuteron cyclotron frequency is observed with deuterium neutral beam injection (f = 60 MHz, B{sub T} = 1.9 T). Enhanced D-D neutron rates are evidence of absorption at the Doppler-shifted cyclotron resonance. Characteristics of global energy confinement provide further proof of substantial beam acceleration by the rf. In many cases, the accelerated deuterons cause temporary stabilization of the sawtooth (monster sawteeth), at relatively low rf power levels of {approximately}1 MW.

  18. Analysis for liquid cryogen spillage in the superconducting cyclotron building at VECC

    CERN Document Server

    Roy S ,; Pal, G; Bhandari, R K

    2009-01-01

    The cryogenic system uses liquid helium and liquid nitrogen to cool the superconducting cyclotron magnet and its cryopanels. In order to assess safety scenarios subsequent to an unusual leakage of cryogens from the system, a deterministic analysis has been carried out to estimate the variation of oxygen concentration with time at several locations of superconducting cyclotron building. The entire process is simulated assuming evaporated cryogens mixes instantaneously with air in the confined space, the ventilation system of the cyclotron building is operational, fresh air continuously enters the confined volume and mixes instantaneously with air in the confined space.

  19. Numerical model of electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2015-12-01

    Full Text Available Important features of the electron cyclotron resonance ion source (ECRIS operation are accurately reproduced with a numerical code. The code uses the particle-in-cell technique to model the dynamics of ions in ECRIS plasma. It is shown that a gas dynamical ion confinement mechanism is sufficient to provide the ion production rates in ECRIS close to the experimentally observed values. Extracted ion currents are calculated and compared to the experiment for a few sources. Changes in the simulated extracted ion currents are obtained with varying the gas flow into the source chamber and the microwave power. Empirical scaling laws for ECRIS design are studied and the underlying physical effects are discussed.

  20. The Electron Cyclotron Resonance Light Source Assembly of PTB - ELISA

    CERN Document Server

    Gruebling, P; Ulm, G

    1999-01-01

    In the radiometry laboratory of the Physikalisch-Technische,Bundesanstalt at the Berlin electron storage ring BESSY I, radiation sources for radiometric applications in industry and basic research in the vacuum ultraviolet (VUV) spectral range are developed, characterized and calibrated. Established sources such as deuterium lamps, Penning and hollow cathode discharge sources have limited spectral ranges and in particular their stability and life time suffers from the erosion of the cathode material. To overcome these limitations we have developed a radiation source based on the principle of the electron cyclotron resonance ion source. ELISA is a 10 GHz monomode source with a compact design featuring a tunable cavity and axially positionable permanent magnets. The radiation emission of the source can be detected simultaneously in the VUV and X-ray spectral range via a toroidal grating monochromator and a Si(Li)-detector. The special design of the source allows spectroscopic investigations of the plasma in dep...

  1. One-electron quantum cyclotron (and implications for cold antihydrogen)

    CERN Document Server

    Gabrielse, G; Odom, B; D'Urso, B

    2001-01-01

    Quantum jumps between Fock states of a one-electron oscillator reveal the quantum limit of a cyclotron accelerator. The states live for seconds when spontaneous emission is inhibited by a factor of 140 within a cylindrical Penning trap cavity. Averaged over hours the oscillator is in thermal equilibrium with black-body photons in the cavity. At 80 mK, quantum jumps occur only when resonant microwave photons are introduced into the cavity, opening a route to improved measurements of the magnetic moments of the electron and positron. The temperature demonstrated is about 60 times lower than the 4.2 K temperature at which charged elementary particles were previously stored. Implications for the production of cold antihydrogen are discussed. (21 refs).

  2. Electromagnetic ion/ion cyclotron instability - Theory and simulations

    Science.gov (United States)

    Winske, D.; Omidi, N.

    1992-01-01

    Linear theory and 1D and 2D hybrid simulations are employed to study electromagnetic ion/ion cyclotron (EMIIC) instability driven by the relative streaming of two field-aligned ion beams. The characteristics of the instability are studied as a function of beam density, propagation angle, electron-ion temperature ratios, and ion beta. When the propagation angle is near 90 deg the EMIIC instability has the characteristics of an electrostatic instability, while at smaller angles electromagnetic effects play a significant role as does strong beam coupling. The 2D simulations point to a narrowing of the wave spectrum and accompanying coherent effects during the linear growth stage of development. The EMIIC instability is an important effect where ion beta is low such as in the plasma-sheet boundary layer and upstream of slow shocks in the magnetotail.

  3. Why NASA and the Space Electronics Community Cares About Cyclotrons

    Science.gov (United States)

    LaBel, Kenneth A.

    2017-01-01

    NASA and the space community are faced with the harsh reality of operating electronic systems in the space radiation environment. Systems need to work reliably (as expected for as long as expected) and be available during critical operations such as docking or firing a thruster. This talk will provide a snapshot of the import of ground-based research on the radiation performance of electronics. Discussion topics include: 1) The space radiation environment hazard, 2) Radiation effects on electronics, 3) Simulation of effects with cyclotrons (and other sources), 4) Risk prediction for space missions, and, 5) Real-life examples of both ground-based testing and space-based anomalies and electronics performance. The talk will conclude with a discussion of the current state of radiation facilities in North America for ground-based electronics testing.

  4. A LabVIEW based cyclotron magnetic field mapping system

    Energy Technology Data Exchange (ETDEWEB)

    Marti, F.; Johnson, P. [NSCL, Michigan State University, East Lansing, MI (United States)

    1999-07-01

    This paper describes the application of National Instruments LabVIEW to the NSCL K500 magnet mapping, as part of the Coupled Cyclotron Upgrade. LabVIEW provides a fast development environment for hardware control from a PC running Windows NT. The PC and LabVIEW environment allow non-professional computer programmers to obtain a reliable and flexible system where modifications can be quickly implemented. This program supports the use of motor controllers, data acquisition cards, digital I/O modules and GPIB instruments. A complete map of 360 degrees is obtained in approximately 90 minutes, measuring 185000 field values with a spacing of 1.6 mm in radius every degree. (author)

  5. Mechanism for electron cyclotron heating of collisionless plasma

    Energy Technology Data Exchange (ETDEWEB)

    Golovanivskii, K.S.; Dugard-Jabon, V.D.; Milant' ev, V.P.

    1975-01-01

    The electron distribution with respect to transverse energy is derived for electron cyclotron resonance in a constant, homogeneous magnetic field; weak relativistic effects are taken into account. After the establishment of a steady-state distribution with groups of hot and cold electrons, no energy is pumped from the rf field to the plasma. The rf electrostatic perturbations are studied on the basis of the distribution function found; it is shown that waves of two types are unstable eigenmodes of the plasma at rest and drift waves. The growth rates for the corresponding instabilities are derived. A study is also made of the stability of right-handed circularly polarized electromagnetic wave propagating along the magnetic field. Instabilities occur at frequencies which depend on the degree of anisotropy, analogous to the case of a plasma with a temperature anisotropy.

  6. Recent developments of cyclotron produced radionuclides for nuclear cardiology

    Science.gov (United States)

    Kulkarni, P. V.; Jansen, D. E.; Corbett, J. R.

    1987-04-01

    For over a decade myocardial perfusion imaging with thallium-201, a cyclotron product, has been routinely used in clinical medicine. Recent advances have allowed the efficient production of very high purity (> 99.8%) iodine-123. New metabolically active 123I labeled radiopharmaceuticals, including alkyl and phenyl fatty acids, and norepinephrine analogs, have been developed and are undergoing clinical trials. Fab' fragments of monoclonal antibodies to cardiac myosin have been labeled with indium-111 ( 111In) and are undergoing clinical evaluation for imaging myocardial infarcts. Monoclonal antibodies to platelets, fibrin, and the thrombolytic agent, tissue plasminogen activator (TPA), have recently been labeled with 111In. Together these developments in radiotracers and instrumentation should have a significant impact on the future of cardiovascular nuclear medicine. This manuscript will discuss developments in single photon emitting radiotracers for myocardial imaging.

  7. Alternative optical concept for electron cyclotron emission imaging.

    Science.gov (United States)

    Liu, J X; Milbourne, T; Bitter, M; Delgado-Aparicio, L; Dominguez, A; Efthimion, P C; Hill, K W; Kramer, G J; Kung, C; Kubota, S; Kasparek, W; Lu, J; Pablant, N A; Park, H; Tobias, B

    2014-11-01

    The implementation of advanced electron cyclotron emission imaging (ECEI) systems on tokamak experiments has revolutionized the diagnosis of magnetohydrodynamic (MHD) activities and improved our understanding of instabilities, which lead to disruptions. It is therefore desirable to have an ECEI system on the ITER tokamak. However, the large size of optical components in presently used ECEI systems have, up to now, precluded the implementation of an ECEI system on ITER. This paper describes a new optical ECEI concept that employs a single spherical mirror as the only optical component and exploits the astigmatism of such a mirror to produce an image with one-dimensional spatial resolution on the detector. Since this alternative approach would only require a thin slit as the viewing port to the plasma, it would make the implementation of an ECEI system on ITER feasible. The results obtained from proof-of-principle experiments with a 125 GHz microwave system are presented.

  8. Data processing in Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Qi, Yulin; O'Connor, Peter B

    2014-01-01

    The Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer intricately couples advanced physics, instrumentation, and electronics with chemical and particularly biochemical research. However, general understanding of the data processing methodologies used lags instrumentation, and most data processing algorithms we are familiar with in FT-ICR are not well studied; thus, professional skill and training in FT-ICR operation and data analysis is still the key to achieve high performance in FT-ICR. This review article is focused on FT-ICR data processing, and explains the procedures step-by-step for users with the goal of maximizing spectral features, such as mass accuracy, resolving power, dynamic range, and detection limits. © 2014 Wiley Periodicals, Inc.

  9. Cyclotron Resonance Gain for FIR and THz Radiation in Graphene

    CERN Document Server

    Cole, Nightvid

    2016-01-01

    A cyclotron resonance maser source using low-effective-mass conduction electrons in graphene, if successful, would allow for generation of Far Infrared (FIR) and Terahertz (THz) radiation without requiring magnetic fields running into the tens of Tesla. In order to investigate this possibility, we consider a device in which electrons are effectively injected via pumping from the valence band to the conduction band using an infrared (IR) laser source, subsequently gyrate in a magnetic field applied perpendicular to the plane of the graphene, and give rise to gain for a FIR/THz wave crossing the plane of the graphene. A set of integral expressions is derived by assuming that the non-radiative energy loss processes of the electrons can be adequately represented by a damping force proportional and antiparallel to their momentum. Minimal gain may occur at very short electron damping times of hundreds of femtoseconds.

  10. The NSCL cyclotron gas stopper – Entering commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, S. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Bollen, G. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); Facility for Rare Isotope Beams, East Lansing, MI (United States); Chouhan, S. [Facility for Rare Isotope Beams, East Lansing, MI (United States); Das, J.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Green, M. [Facility for Rare Isotope Beams, East Lansing, MI (United States); Magsig, C. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Morrissey, D.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States); Ottarson, J.; Sumithrarachchi, C. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Villari, A.C.C.; Zeller, A. [Facility for Rare Isotope Beams, East Lansing, MI (United States)

    2016-06-01

    Linear gas stopping cells have been used successfully at NSCL to slow down ions produced by projectile fragmentation from the 100 MeV/u to the keV energy range. These ‘stopped beams’ have first been used for low-energy high precision experiments and more recently for NSCLs re-accelerator ReA. A gas-filled reverse cyclotron is currently under construction by the NSCL to complement the existing stopping cells: Due to its extended stopping length, efficient stopping and fast extraction is expected even for light and medium-mass ions, which are difficult to thermalize in linear gas cells. The device is based on a 2.6 T maximum-field cyclotron-type magnet to confine the injected beam while it is slowed down in ≈100 mbar of LN{sub 2}-temperature helium gas. Once thermalized, the beam will be transported to the center of the device by a traveling-wave RF-carpet system, extracted along the symmetry axis with an ion conveyor and miniature RF-carpets, and accelerated to a few tens of keV of energy for delivery to the users. The superconducting magnet has been constructed on a 60 kV platform and energized to its nominal field strength. The magnet’s two cryostats use 3 cryo-refrigerators each and liquid-nitrogen cooled thermal shields to cool the coil pair to superconductivity. This concept, chosen not to have to rely on external liquid helium, has been working well. Measurements of axial and radial field profiles confirm the field calculations. The individual RF-ion guiding components for low-energy ion transport through the device have been tested successfully. The beam stopping chamber with its 0.9 m-diameter RF carpet system and the ion extraction system are being prepared for installation inside the magnet for low-energy ion transport tests.

  11. A Tuning Method for Electrically Compensated Ion Cyclotron Resonance Mass Spectrometer Traps

    Science.gov (United States)

    Brustkern, Adam M.; Rempel, Don L.; Gross, Michael L.

    2010-01-01

    We describe a method for tuning electrically compensated ion cyclotron resonance (ICR) traps by tracking the observed cyclotron frequency of an ion cloud at different oscillation mode amplitudes. Although we have used this method to tune the compensation voltages of a custom-built electrically compensated trap, the approach is applicable to other designs that incorporate electrical compensation. To evaluate the effectiveness of tuning, we examined the frequency shift as a function of cyclotron orbit size at different z-mode oscillation amplitudes. The cyclotron frequencies varied by ~ 12 ppm for ions with low z-mode oscillation amplitudes compared to those with high z-mode amplitudes. This frequency difference decreased to ~1 ppm by one iteration of trap tuning. PMID:20060743

  12. Realistic simulations of a cyclotron spiral inflector within a particle-in-cell framework

    Science.gov (United States)

    Winklehner, Daniel; Adelmann, Andreas; Gsell, Achim; Kaman, Tulin; Campo, Daniela

    2017-12-01

    We present an upgrade to the particle-in-cell ion beam simulation code opal that enables us to run highly realistic simulations of the spiral inflector system of a compact cyclotron. This upgrade includes a new geometry class and field solver that can handle the complicated boundary conditions posed by the electrode system in the central region of the cyclotron both in terms of particle termination, and calculation of self-fields. Results are benchmarked against the analytical solution of a coasting beam. As a practical example, the spiral inflector and the first revolution in a 1 MeV /amu test cyclotron, located at Best Cyclotron Systems, Inc., are modeled and compared to the simulation results. We find that opal can now handle arbitrary boundary geometries with relative ease. Simulated injection efficiencies and beam shape compare well with measured efficiencies and a preliminary measurement of the beam distribution after injection.

  13. Cyclotron-based nuclear science. Progress report, April 1, 1979-March 31, 1980

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    Research at the cyclotron institute is summarized. These major areas are covered: nuclear structure; nuclear reactions and scattering; polarization studies; interdisciplinary nuclear science; instrumentation and systems development; and publications. (GHT)

  14. Magnetic Alfvén‐cyclotron fluctuations of anisotropic nonthermal plasmas

    National Research Council Canada - National Science Library

    Navarro, Roberto E; Muñoz, Víctor; Araneda, Jaime; Viñas, Adolfo F.‐; Moya, Pablo S; Valdivia, Juan A

    2015-01-01

    .... Here we study magnetic Alfvén‐cyclotron fluctuations propagating along a background magnetic field in a plasma composed of thermal and suprathermal protons and electrons via the fluctuation...

  15. Research of the Electron Cyclotron Emission with Vortex Property excited by high power high frequency Gyrotron

    Science.gov (United States)

    Goto, Yuki; Kubo, Shin; Tsujimura, Tohru; Takubo, Hidenori

    2017-10-01

    Recently, it has been shown that the radiation from a single electron in cyclotron motion has vortex property. Although the cyclotron emission exists universally in nature, the vortex property has not been featured because this property is normally cancelled out due to the randomness in gyro-phase of electrons and the development of detection of the vortex property has not been well motivated. In this research, we are developing a method to generate the vortex radiation from electrons in cyclotron motion with controlled gyro-phase. Electron that rotates around the uniform static magnetic field is accelerated by right-hand circular polarized (RHCP) radiation resonantly when the cyclotron frequency coincides with the applied RHCP radiation frequency. A large number of electrons can be coherently accelerated in gyro-phase by a RHCP high power radiation so that these electrons can radiate coherent emission with vortex feature. We will show that vortex radiation created by purely rotating electrons for the first time.

  16. Measurement of ion cyclotron emissions by use of ICRF heating antennas in LHD

    Energy Technology Data Exchange (ETDEWEB)

    Saito, K. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)], E-mail: saito@nifs.ac.jp; Kasahara, H.; Seki, T.; Kumazawa, R.; Mutoh, T.; Watanabe, T.; Shimpo, F.; Nomura, G.; Osakabe, M. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Ichimura, M. [Tsukuba University, Plasma Research Center, Tsukuba, Ibaraki 305-8577 (Japan); Higaki, H. [Hiroshima University, Higashi-Hiroshima, Hiroshima 739-8530 (Japan); Komori, A. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)

    2009-06-15

    Ion cyclotron emissions (ICEs) were clearly detected in the Large Helical Device (LHD) during perpendicular neutral beam (NB) injection. Antennas for the ion cyclotron range of frequencies (ICRF) heating were used as probes. The frequencies of ICEs were proportional to magnetic field strength. The location of ICE excitation was a peripheral region of plasma and the source particles were lost-ions injected by the perpendicular NB.

  17. Simulation, design, and testing of a high power collimator for the RDS-112 cyclotron.

    Science.gov (United States)

    Peeples, Johanna L; Stokely, Matthew H; Poorman, Michael C; Bida, Gerald T; Wieland, Bruce W

    2015-03-01

    A high power [F-18] fluoride target package for the RDS-112 cyclotron has been designed, tested, and commercially deployed. The upgrade includes the CF-1000 target, a 1.3kW water target with an established commercial history on RDS-111/Eclipse cyclotrons, and a redesigned collimator with improved heat rejection capabilities. Conjugate heat transfer analyses were employed to both evaluate the existing collimator capabilities and design a suitable high current replacement. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Optically detected cyclotron resonance in a single GaAs/AlGaAs heterojunction

    Energy Technology Data Exchange (ETDEWEB)

    Bartsch, Gregor

    2011-09-23

    Optically detected far-infrared cyclotron resonance (FIR-ODCR) in GaAs/AlGaAs HJs is interpreted in the frame of an exciton-dissociation mechanism. It is possible to explain the ODR mechanism by an exciton drag, mediated by ballistically propagating phonons. Furthermore, very narrow resonances are presented and realistic electron mobility values can be calculated. The exceptionally narrow ODCRs allow to measure conduction-band nonparabolicity effects and resolve satellite resonances, close to the main cyclotron resonance line.

  19. Symmetry Properties of Proton Velocity Distributions: a Vlasov Simulation Study of the Ion Cyclotron Instability

    Science.gov (United States)

    Araneda, J. A.; López, R. A.; Vinas, A. F.

    2014-12-01

    The ion cyclotron instability is driven by a sufficiently large proton temperature anisotropy, generating a spectrum of counterpropagating field-aligned ion cyclotron fluctuations. In this work, we use low-noise one-dimensional electromagnetic Vlasov simulations in a magnetized and collisionless plasma of fluid electrons and one ion species to study the evolution of proton velocity distributions during the thermal relaxation process. Special attention is given to deviations from initial bi-Maxwellian shapes.

  20. Determination of Magnet Specification of 13 MeV Proton Cyclotron Based on Opera 3D

    Directory of Open Access Journals (Sweden)

    Taufik

    2014-08-01

    Full Text Available The magnet is one of the main components of a cyclotron, used to form a circular particle beam trajectories and to provide focusing of the beam. To support the mastery of 13-MeV proton cyclotron technologies, cyclotron magnet design must be done to satisfy cyclotron magnet requirements. This research was conducted by studying important parameters in designing the cyclotron magnet which is then used to determine the design requirements. The magnet design was based on the results of a 3D simulation using Opera 3D software. Opera 3D is a software developed by Cobham plc to solve physical problems in 3D such as magnetostatic using finite element methods. The simulation started by drawing a 3D model of the magnet using a modeler, followed by magnetic field calculations by Tosca module in the Opera 3D software. Simulation results were analyzed with the Genspeo software to determine whether the parameters of the cyclotron magnet have met design requirements. The results indicate that the magnet design satisfied the cyclotron magnet design requirement, that B in the median plane of the magnetic pole approached the isochronous curve, providing axial and radial focusing beam, crossing the resonance line at vr = 1 when the particle energy is low and the particle energy is more than 13 MeV, and lead to small enough phase shift of about 13°. The dimension of the cyclotron magnet is 1.96 m × 1.30 m × 1.21 m; its weight is 17.3 ton; its coil current is 88,024 ampere-turn; its center magnetic field is 1.27479 T; its maximum magnetic field is 1.942116 T; its minimum magnetic field is 0.7689 T; its valley gap is 120 mm; its hill gaps are 40 to 50.78 mm; and its hill angles are 35° to 44°.to 44°

  1. Bi-directional Alfv\\'en Cyclotron Instabilities in the Mega-Amp Spherical Tokamak

    CERN Document Server

    Sharapov, S E; Akers, R; Ayed, N Ben; Cecconello, M; Cook, J W C; Cunningham, G; Verwichte, E; Tea, the MAST

    2014-01-01

    Alfv\\'en cyclotron instabilities excited by velocity gradients of energetic beam ions were investigated in MAST experiments with super-Alfv\\'enic NBI over a wide range of toroidal magnetic fields from ~0.34 T to ~0.585 T. In MAST discharges with high magnetic field, a discrete spectrum of modes in the sub-cyclotron frequency range is excited toroidally propagating counter to the beam and plasma current (toroidal mode numbers n < 0).

  2. Coupling of electrostatic ion cyclotron and ion acoustic waves in the solar wind

    Energy Technology Data Exchange (ETDEWEB)

    Sreeraj, T., E-mail: sreerajt13@iigs.iigm.res.in [Indian Institute of Geomagnetism, Navi Mumbai (India); Singh, S. V., E-mail: satyavir@iigs.iigm.res.in; Lakhina, G. S., E-mail: gslakhina@gmail.com [Indian Institute of Geomagnetism, Navi Mumbai (India); University of the Western Cape, Bellville 7535, Capetown (South Africa)

    2016-08-15

    The coupling of electrostatic ion cyclotron and ion acoustic waves is examined in three component magnetized plasma consisting of electrons, protons, and alpha particles. In the theoretical model relevant to solar wind plasma, electrons are assumed to be superthermal with kappa distribution and protons as well as alpha particles follow the fluid dynamical equations. A general linear dispersion relation is derived for such a plasma system which is analyzed both analytically and numerically. For parallel propagation, electrostatic ion cyclotron (proton and helium cyclotron) and ion acoustic (slow and fast) modes are decoupled. For oblique propagation, coupling between the cyclotron and acoustic modes occurs. Furthermore, when the angle of propagation is increased, the separation between acoustic and cyclotron modes increases which is an indication of weaker coupling at large angle of propagation. For perpendicular propagation, only cyclotron modes are observed. The effect of various parameters such as number density and temperature of alpha particles and superthermality on dispersion characteristics is examined in details. The coupling between various modes occurs for small values of wavenumber.

  3. Influence of injection beam emittance on beam transmission efficiency in a cyclotron.

    Science.gov (United States)

    Kurashima, Satoshi; Kashiwagi, Hirotsugu; Miyawaki, Nobumasa; Yoshida, Ken-Ichi; Okumura, Susumu

    2014-02-01

    The JAEA AVF cyclotron accelerates various kinds of high-energy ion beams for research in biotechnology and materials science. Beam intensities of an ion species of the order of 10(-9)-10(-6) ampere are often required for various experiments performed sequentially over a day. To provide ion beams with sufficient intensity and stability, an operator has to retune an ion source in a short time. However, the beam intensity downstream of the cyclotron rarely increases in proportion to the intensity at the ion source. To understand the cause of this beam behavior, transmission efficiencies of a (12)C(5+) beam from an electron cyclotron resonance ion source to the cyclotron were measured for various conditions of the ion source. Moreover, a feasible region for acceleration in the emittance of the injection beam was clarified using a transverse-acceptance measuring system. We confirmed that the beam emittance and profile were changed depending on the condition of the ion source and that matching between the beam emittance and the acceptance of the cyclotron was degraded. However, after fine-tuning to improve the matching, beam intensity downstream of the cyclotron increased.

  4. Towards quantitative simulations of high power proton cyclotrons

    Directory of Open Access Journals (Sweden)

    Y. J. Bi

    2011-05-01

    Full Text Available We describe a large scale simulation effort using Object Oriented Parallel Accelerator Library, that leads to a better quantitative understanding of the existing Paul Scherrer Institut high power proton cyclotron facility. The 1.3 MW of beam power on target poses stringent constraints on the controlled and uncontrolled beam losses. We present initial conditions for the Ring simulation, obtained from the new time-structure measurement and the many profile monitors of the 72 MeV transfer line. A trim coil model is developed, including trim coil TC15, which is needed to avoid the dangerous ν_{r}=2ν_{z} resonance. By properly selecting the injection position and angle (eccentric injection, the flattop voltage, and phase, very good agreement between simulations and measurements at the radial probe RRE4 is obtained. We report on 3–4 orders of magnitude in dynamic range when comparing simulations with measurements. The relation between beam intensity, rms beam size, and accelerating voltage is studied and compared with measurement. The demonstrated capabilities are mandatory in the design and operation of the next generation high power proton drivers. In an outlook we discuss our future plans to include more physics into the model, which eventually leads to an even larger dynamic range in the simulation.

  5. Electron-cyclotron plasma startup in the GDT experiment

    CERN Document Server

    Yakovlev, D V; Gospodchikov, E D; Solomakhin, A L; Savkin, V Ya; Bagryansky, P A

    2016-01-01

    The paper reports on a new plasma startup scenario in the Gas Dynamic Trap (GDT) magnetic mirror device. The primary 5 MW neutral beam injection (NBI) plasma heating system fires into a sufficiently dense plasma target ("seed plasma"), which is commonly supplied by an arc plasma generator. In the reported experiments, a different approach to seed plasma generation is explored. One of the channels of the electron cyclotron resonance (ECR) heating system is used to ionize the neutral gas and build up the density of plasma to a level suitable for NBI capture. After a short transition (about 1 ms) the discharge becomes essentially similar to a standard one initiated by the plasma gun. The paper presents the discharge scenario and experimental data on the seed plasma evolution during ECR heating, along with the dependencies on incident microwave power, magnetic configuration and pressure of a neutral gas. The characteristics of consequent high-power NBI discharge are studied and differences to the conventional sce...

  6. Simulating Electron Cyclotron Maser Emission for Low Mass Stars

    Science.gov (United States)

    Llama, Joe; Jardine, Moira

    2018-01-01

    Zeeman-Doppler Imaging (ZDI) is a powerful technique that enables us to map the large-scale magnetic fields of stars spanning the pre- and main-sequence. Coupling these magnetic maps with field extrapolation methods allow us to investigate the topology of the closed, X-ray bright corona, and the cooler, open stellar wind.Using ZDI maps of young M dwarfs with simultaneous radio light curves obtained from the VLA, we present the results of modeling the Electron-Cyclotron Maser (ECM) emission from these systems. We determine the X-ray luminosity and ECM emission that is produced using the ZDI maps and our field extrapolation model. We compare these findings with the observed radio light curves of these stars. This allows us to predict the relative phasing and amplitude of the stellar X-ray and radio light curves.This benchmarking of our model using these systems allows us to predict the ECM emission for all stars that have a ZDI map and an observed X-ray luminosity. Our model allows us to understand the origin of transient radio emission observations and is crucial for disentangling stellar and exoplanetary radio signals.

  7. Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array.

    Science.gov (United States)

    Park, Sung-Gun; Anderson, Gordon A; Navare, Arti T; Bruce, James E

    2016-01-19

    Mass measurement accuracy is a critical analytical figure-of-merit in most areas of mass spectrometry application. However, the time required for acquisition of high-resolution, high mass accuracy data limits many applications and is an aspect under continual pressure for development. Current efforts target implementation of higher electrostatic and magnetic fields because ion oscillatory frequencies increase linearly with field strength. As such, the time required for spectral acquisition of a given resolving power and mass accuracy decreases linearly with increasing fields. Mass spectrometer developments to include multiple high-resolution detectors that can be operated in parallel could further decrease the acquisition time by a factor of n, the number of detectors. Efforts described here resulted in development of an instrument with a set of Fourier transform ion cyclotron resonance (ICR) cells as detectors that constitute the first MS array capable of parallel high-resolution spectral acquisition. ICR cell array systems consisting of three or five cells were constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. Independent ion populations were injected and trapped within each cell in the array. Upon filling the array, all ions in all cells were simultaneously excited and ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition, parallel mass spectrometry (MS) and MS/MS measurements, and parallel high-resolution acquisition with the MS array system.

  8. Development of helium electron cyclotron wall conditioning on TCV

    Science.gov (United States)

    Douai, D.; Goodman, T.; Isayama, A.; Fukumoto, M.; Wauters, T.; Sozzi, C.; Coda, S.; Blanchard, P.; Figini, L.; Garavaglia, S.; Miyata, Y.; Moro, A.; Ricci, D.; Silva, M.; Theiler, C.; Vartanian, S.; Verhaegh, K.; the EUROfusion MST1 Team; the TCV Team

    2018-02-01

    JT-60SA envisions electron cyclotron wall conditioning (ECWC), as wall conditioning method in the presence of the toroidal field to control fuel and impurity recycling and to improve plasma performance and reproducibility. This paper reports on Helium ECWC experiments on TCV in support of JT-60SA operation. Nearly sixty Helium conditioning discharges have been successfully produced in TCV, at a toroidal field B T  =  1.3 or 1.54 T, with gyrotrons at 82.7 GHz in X2 mode, mimicking ECWC operation in JT-60SA at the second harmonic of the EC wave. Discharge parameters were tuned in order to (i) minimize the time for the onset of ECWC plasmas, thus minimizing absorption of stray radiation by in-vessel components, (ii) improve discharge homogeneity by extending the discharge vertically and radially, and wall coverage, in particular of inboard surfaces where JT-60SA plasmas will be initiated, (iii) assess the efficiency of He-ECWC to deplete carbon walls from fuel. An optimized combination of vertical and radial magnetic fields, with amplitudes typically 0.1 to 0.6% of that of B T, has been determined, which resulted in lowest breakdown time, improved wall coverage and enhanced fuel removal. A standard ohmic D 2-plasma could be then sustained, whereas it would not have been possible without He-ECWC.

  9. High current DC negative ion source for cyclotron.

    Science.gov (United States)

    Etoh, H; Onai, M; Aoki, Y; Mitsubori, H; Arakawa, Y; Sakuraba, J; Kato, T; Mitsumoto, T; Hiasa, T; Yajima, S; Shibata, T; Hatayama, A; Okumura, Y

    2016-02-01

    A filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In Cs-free operation, continuous H(-) beam of 10 mA and D(-) beam of 3.3 mA were obtained stably at an arc-discharge power of 3 kW and 2.4 kW, respectively. In Cs-seeded operation, H(-) beam current reached 22 mA at a lower arc power of 2.6 kW with less co-extracted electron current. The optimum gas flow rate, which gives the highest H(-) current, was 15 sccm in the Cs-free operation, while it decreased to 4 sccm in the Cs-seeded operation. The relationship between H(-) production and the design/operating parameters has been also investigated by a numerical study with KEIO-MARC code, which gives a reasonable explanation to the experimental results of the H(-) current dependence on the arc power.

  10. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 14

    Energy Technology Data Exchange (ETDEWEB)

    1967-01-10

    The past quarter has seen further progress in the solution of the problem of achieving a cyclotron which meets or exceeds the performance requirements. The magnet system, with the exception of the trim coils and their supplies, is all on order or about to be ordered, and a high confidence level exists that the system will meet all requirements. The rf system studies, nearly complete, have indicated that the solution chosen will meet the frequency requirements and will be within the power expected. The center studies, complete in the first phase, have resulted in a preliminary center design of the electrostatic focusing system and a design of the magnetic center which provides the required axial focusing. A high degree of cooperation on the center study programs between the U of M and CSF has efficiently yielded these results. The overall schedule continues to be maintained, and the program is expected to be completed on the 37-month schedule. For better control and greater visibility on schedule progress, two reference points have been selected as more immediate objectives. These are 17 July 1967 for the start of the magnet testing program and 2 October 1967 as the start of the rf high power tests. Each task involved is being analyzed with these dates in mind, and they appear to be reasonable.

  11. Characteristic Experimentations of Degrader and Scatterer at MC-50 Cyclotron

    CERN Document Server

    Lee Seok Ki; Kim, Kye-Ryung; Lee, Hwa-Ryun; Park, Bum-Sik

    2005-01-01

    Building proton beam user facilities, especially deciding beam energy level, depends on the attached proton accelerator and users' needs. To adjust beam energy level, two methods are generally used. One is to directly adjust the beam in the accelerator. The other is to adjust beam energy after extracting from the accelerator. Degrader/Scatterer System has been installed in the MC-50 Cyclotron to adjust energy level of the beam used for various application fields. Its degrader and scatterer are made of Al foils and Au foils, respectively. Al thickness are 2, 1, 0.5, 0.3, 0.2, 0.1, 0.05, 0.03, 0.02, 0.01mm and Au thickness are 0.2, 0.1, 0.05, 0.03, 0.02, 0.01mm, respectively. In this study, suitable beam condition was adjusted through overlapping Al/Au foils of various thickness through simulation results. After that, LET(Linear Energy Transfer) value was indirectly acquired by measuring the bragg peak of the external beam through PMMA plastic Phantom and profile was measured by film dosimetry.

  12. Isotope exchange by Ion Cyclotron Wall Conditioning on JET

    Energy Technology Data Exchange (ETDEWEB)

    Wauters, T., E-mail: t.wauters@fz-juelich.de [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Douai, D.; Kogut, D. [CEA, IRFM, F-13108 St-Paul-Lez-Durance (France); Lyssoivan, A. [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Brezinsek, S. [Forschungszentrum Jülich, Institut für Energie- und Klimaforschung Plasmaphysik, 52425 Jülich (Germany); Belonohy, E. [Max-Planck Institut für Plasmaphysik, 85748 Garching (Germany); Blackman, T. [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Bobkov, V. [Max-Planck Institut für Plasmaphysik, 85748 Garching (Germany); Crombé, K. [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Drenik, A. [Jožef Stefan Institute, 1000 Ljubljana (Slovenia); Graham, M. [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Joffrin, E. [CEA, IRFM, F-13108 St-Paul-Lez-Durance (France); Lerche, E. [Laboratory for Plasma Physics, ERM/KMS, TEC Partner, 1000 Brussels (Belgium); Loarer, T. [CEA, IRFM, F-13108 St-Paul-Lez-Durance (France); Lomas, P.L.; Mayoral, M.-L.; Monakhov, I. [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Oberkofler, M. [Max-Planck Institut für Plasmaphysik, 85748 Garching (Germany); Philipps, V. [Forschungszentrum Jülich, Institut für Energie- und Klimaforschung Plasmaphysik, 52425 Jülich (Germany); Plyusnin, V. [IST, Instituto de Plasmas e Fusão Nuclear, 1049-001 Lisboa (Portugal); and others

    2015-08-15

    The isotopic exchange efficiencies of JET Ion Cyclotron Wall Conditioning (ICWC) discharges produced at ITER half and full field conditions are compared for JET carbon (C) and ITER like wall (ILW). Besides an improved isotope exchange rate on the ILW providing cleaner plasma faster, the main advantage compared to C-wall is a reduction of the ratio of retained discharge gas to removed fuel. Complementing experimental data with discharge modeling shows that long pulses with high (∼240 kW coupled) ICRF power maximizes the wall isotope removal per ICWC pulse. In the pressure range 1–7.5 × 10{sup −3} Pa, this removal reduces with increasing discharge pressure. As most of the wall-released isotopes are evacuated by vacuum pumps in the post discharge phase, duty cycle optimization studies for ICWC on JET-ILW need further consideration. The accessible reservoir by H{sub 2}-ICWC at ITER half field conditions on the JET-ILW preloaded by D{sub 2} tokamak operation is estimated to be 7.3 × 10{sup 22} hydrogenic atoms, and may be exchanged within 400 s of cumulated ICWC discharge time.

  13. Electron cyclotron wave sources and applications for fusion

    Science.gov (United States)

    Thomassen, K. I.

    1990-03-01

    Advances in magnetic fusion research have come as often from the use of new technologies as from the invention of ideas and discovery of phenomena that are then applied to new experiments. The technologies needed for plasma production, heating, confinement, and control have largely been developed and are a major factor in the success of our current experiments. These include high vacuum techniques, normal and superconducting magnets, particle beams, pellet fueling devices, and rf sources in the ion cylotron and lower hybrid range of frequencies. One area where development is especially required, and where the potential impact on fusion research is large, is that of electron cyclotron wave (ECW) sources in the 100-600 GHz range. This journal issue is devoted to methods for ECW generation and transmission, and to applications including heating, current drive, profile shaping, and instability control. To help focus these articles the requirements(1) for a system to heat the Compact Ignition Tokamak (CIT) were used to define the necessary technology. Somewhat lower frequencies, but similar power, is anticipated(2) for the International Thermonuclear Experimental Reactor (ITER), and for future large devices of that class, should they use ECW sources in them.

  14. Applied research with cyclotron beams at FLNR JINR

    Energy Technology Data Exchange (ETDEWEB)

    Oganessian, Yu.Ts.; Apel, P.Yu.; Didyk, A.Yu.; Dmitriev, S.N.; Gulbekian, G.G. [Joint Inst. for Nuclear Research, Dubna, Moscow (Russian Federation). Flerov Lab. of Nuclear Reactions

    1997-03-01

    The Center of Applied Physics at the Flerov Laboratory carries out an R and D program comprising development of track membrane technology, materials research with heavy ion beams and production of radioisotopes. Experiments are performed on three cyclotrons: U-400, U-200 and IC-100 providing a wide variety of ion beams with the energies of 1 to 10 MeV/u. The activity on track membranes (TMs) includes studies of track formation in polymers and latent track structure, track sensitization and etching, methods of membrane testing, development of track membranes on the basis of new materials, surface modification of TMs, design and construction of facilities for track membrane production. Recent experiments on heavy ion-induced radiation damage in non-polymeric substances have been devoted to defect creation in semiconductor and dielectric single crystals. TEM, SEM, STM and `in situ` luminescent spectroscopy are used to investigate heavy ion effects. Methods for producing several isotopes of high radiochemical and isotopic purity for medical, biomedical and environmental protection applications have been developed. (author)

  15. Electron cyclotron plasma startup in the GDT experiment

    Science.gov (United States)

    Yakovlev, D. V.; Shalashov, A. G.; Gospodchikov, E. D.; Solomakhin, A. L.; Savkin, V. Ya.; Bagryansky, P. A.

    2017-01-01

    We report on a new plasma startup scenario in the gas dynamic trap (GDT) magnetic mirror device. The primary 5 MW neutral beam injection (NBI) plasma heating system fires into a sufficiently dense plasma target (‘seed plasma’), which is commonly supplied by an arc plasma generator. In the reported experiments, a different approach to seed plasma generation is explored. One of the channels of the electron cyclotron resonance (ECR) heating system is used to ionize the neutral gas and build up the density of plasma to a level suitable for NBI capture. After a short transition of approximately 1 ms the discharge becomes essentially similar to a standard one initiated by the plasma gun. This paper presents the discharge scenario and experimental data on the seed plasma evolution during ECRH, along with the dependencies on incident microwave power, magnetic configuration and pressure of a neutral gas. The characteristics of the consequent high-power NBI discharge are studied and differences from the conventional scenario are discussed. A theoretical model describing the ECR breakdown and the seed plasma accumulation in a large-scale mirror trap is developed on the basis of the GDT experiment.

  16. Electron cyclotron emission measurements at the stellarator TJ-K

    Energy Technology Data Exchange (ETDEWEB)

    Sichardt, Gabriel; Ramisch, Mirko [Institut fuer Grenzflaechenverfahrenstechnik und Plasmatechnologie, Universitaet Stuttgart (Germany); Koehn, Alf [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany)

    2016-07-01

    Electron temperature (T{sub e}) measurements in the magnetised plasmas of the stellarator TJ-K are currently performed by means of Langmuir probes. The use of these probes is restricted to relatively low temperatures and the measurement of temperature profiles requires the acquisition of the local current-voltage characteristics which limits strongly the sampling rate. As an alternative, T{sub e} can be measured using the electron cyclotron emission (ECE) that is generated by the gyration of electrons in magnetised plasmas. Magnetic field gradients in the plasma lead to a spatial distribution of emission frequencies and thus the measured intensity at a given frequency can be related to its point of origin. The T{sub e} dependence of the intensity then leads to a temperature profile along the line of sight for Maxwellian velocity distributions. A diagnostic system for T{sub e} measurements using ECE is currently being set up at TJ-K. When non-thermal electrons are present the emission spectrum changes dramatically. Therefore, the ECE can also be used to investigate the contribution of fast electrons to previously observed toroidal net currents in TJ-K. Simulations are used to examine the role of electron drift orbits in generating these currents.

  17. On the origin of cyclotron lines in the spectra of X-ray pulsars

    Directory of Open Access Journals (Sweden)

    Mushtukov A. A.

    2014-01-01

    Full Text Available Cyclotron resonance scattering features are observed in the spectra of some X-ray pulsars and show significant changes in the line energy with the pulsar luminosity. In a case of bright sources, the line centroid energy is anti-correlated with the luminosity. Such a behaviour is often associated with the onset and growth of the accretion column, which is believed to be the origin of the observed emission and the cyclotron lines. However, this scenario inevitably implies large gradient of the magnetic field strength within the line-forming region, and it makes the formation of the observed line-like features problematic. Moreover, the observed variation of the cyclotron line energy is much smaller than could be anticipated for the corresponding luminosity changes. We argue that a more physically realistic situation is that the cyclotron line forms when the radiation emitted by the accretion column is reflected from the neutron star surface. The idea is based on the facts that a substantial part of column luminosity is intercepted by the neutron star surface and the reflected radiation should contain absorption features. The reflection model is developed and applied to explain the observed variations of the cyclotron line energy in a bright X-ray pulsar V 0332+53 over a wide range of luminosities.

  18. Support vector machine based fault detection approach for RFT-30 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Young Bae, E-mail: ybkong@kaeri.re.kr; Lee, Eun Je; Hur, Min Goo; Park, Jeong Hoon; Park, Yong Dae; Yang, Seung Dae

    2016-10-21

    An RFT-30 is a 30 MeV cyclotron used for radioisotope applications and radiopharmaceutical researches. The RFT-30 cyclotron is highly complex and includes many signals for control and monitoring of the system. It is quite difficult to detect and monitor the system failure in real time. Moreover, continuous monitoring of the system is hard and time-consuming work for human operators. In this paper, we propose a support vector machine (SVM) based fault detection approach for the RFT-30 cyclotron. The proposed approach performs SVM learning with training samples to construct the classification model. To compensate the system complexity due to the large-scale accelerator, we utilize the principal component analysis (PCA) for transformation of the original data. After training procedure, the proposed approach detects the system faults in real time. We analyzed the performance of the proposed approach utilizing the experimental data of the RFT-30 cyclotron. The performance results show that the proposed SVM approach can provide an efficient way to control the cyclotron system.

  19. mA beam acceleration efforts on 100 MeV H- cyclotron at CIAE

    Science.gov (United States)

    Zhang, Tianjue; An, Shizhong; Lv, Yinlong; Ge, Tao; Jia, Xianlu; Ji, Bin; Yin, Zhiguo; Pan, Gaofeng; Cao, Lei; Guan, Fengping; Yang, Jianjun; Li, Zhenguo; Zhao, Zhenlu; Wu, Longcheng; Zhang, He; Wang, Jingfeng; Zhang, Yiwang; Liu, Jingyuan; Li, Shiqiang; Lu, Xiaotong; Liu, Zhenwei; Li, Yaoqian; Guo, Juanjuan; Cao, Xuelong; Guan, Leilei; Wang, Fei; Wang, Yang; Yang, Guang; Zhang, Suping; Hou, Shigang; Wang, Feng

    2017-09-01

    Various technologies for high current compact H- cyclotron have been developed at CIAE since 1990s. A 375 μA proton beam was extracted from a 30 MeV compact H- cyclotron CYCIAE-30 at the end of 1994. A central region model cyclotron CYCIAE-CRM was developed for the design verification of a 100 MeV high current compact H- cyclotron CYCIAE-100. It is also a 10 MeV proton machine as a prototype for PET application. A 430 μA beam was achieved in 2009. The first beam was extracted from the CYCIAE-100 cyclotron on July 4, 2014, the operation stability has been improved and beam current has been increased gradually. A 1.1 mA proton beam was measured on the internal target in July 2016. The effort for an increasing of proton beam has continued till now. In this paper, the effort on several aspects for mA beam development will be presented, including the multi-cusp source, buncher, matching from the energy of the injected beam, vertical beam line and central region, beam loading of the RF system and instrumentation for beam diagnostics etc.

  20. Modeling whistler wave generation regimes in magnetospheric cyclotron maser

    Directory of Open Access Journals (Sweden)

    D. L. Pasmanik

    2004-11-01

    Full Text Available Numerical analysis of the model for cyclotron instability in the Earth's magnetosphere is performed. This model, based on the self-consistent set of equations of quasi-linear plasma theory, describes different regimes of wave generation and related energetic particle precipitation. As the source of free energy the injection of energetic electrons with transverse anisotropic distribution function to the interaction region is considered. A parametric study of the model is performed. The main attention is paid to the analysis of generation regimes for different characteristics of energetic electron source, such as the shape of pitch angle distributions and its intensity. Two mechanisms of removal of energetic electrons from a generation region are considered, one is due to the particle precipitation through the loss cone and another one is related to the magnetic drift of energetic particles.

    It was confirmed that two main regimes occur in this system in the presence of a constant particle source, in the case of precipitation losses. At small source intensity relaxation oscillations were found, whose parameters are in good agreement with simplified analytical theory developed earlier. At a larger source intensity, transition to a periodic generation occurs. In the case of drift losses the regime of self-sustained periodic generation regime is realized for source intensity higher than some threshold. The dependencies of repetition period and dynamic spectrum shape on the source parameters were studied in detail. In addition to simple periodic regimes, those with more complex spectral forms were found. In particular, alteration of spikes with different spectral shape can take place. It was also shown that quasi-stationary generation at the low-frequency band can coexist with periodic modulation at higher frequencies.

    On the basis of the results obtained, the model for explanation of

  1. Electron-cyclotron heating in the Constance 2 mirror experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mauel, Michael E.

    1982-09-01

    Electron cyclotron heating of a highly-ionized plasma in mirror geometry is investigated. The experimental diagnosis of the electron energy distribution and the comparison of the results of this diagnosis with a two dimensional, time-dependent Fokker-Planck simulation are accomplished in four steps. (1) First, the power balance of the heated and unheated Constance 2 plasma is analyzed experimentally. It is concluded that the heated electrons escape the mirror at a rate dominated by a combination of the influx of cool electrons from outside the mirror and the increased loss rate of the ions. (2) The microwave parameters at the resonance zones are then calculated by cold-plasma ray tracing. High N/sub parallel/ waves are launched and for these waves, strong first-pass absorption is predicted. The absorption strength is qualitatively checked in the experiment by surrounding the plasma with non-reflecting liners. (3) A simplified quasilinear theory including the effect of N/sub parallel/ is developed to model the electrons. An analytic expression is derived for the RF-induced pump-out of the magnetically-confined warm electrons. Results of the Fokker-Planck simulations show the development of the electron energy distribution for several plasma conditions and verify the scaling of the analytic expression for RF-induced diffusion into the loss cone. (4) Sample x-ray and endloss data are presented, and the overall comparison between the simulation and experiment is discussed. The x-ray signals indicate that, for greater RF power, the hot electrondensity increases more rapidly than its temperature. The time history of the endloss data, illustrating RF-enhancement, suggests the predicted scaling for warm-electron pump-out. Finally, a comparison between the measured and predicted energy distribution shows that the bulk, warm and hot components of the heated Constance 2 electrons are indeed reproduced by the simulation.

  2. Electron cyclotron resonance heating in the microwave tokamak experiment

    Energy Technology Data Exchange (ETDEWEB)

    Allen, S.L.; Casper, T.A.; Fenstermacher, M.E. [and others

    1992-09-01

    This paper presents the results from a series of Electron Cyclotron Resonance Heating (ECRH) experiments on the Microwave Tokamak Experiment (MTX). On-axis heating at B{sub T} = 5T (f{sub ce} = 140 GHz) has been performed at electron densities up to cutoff. We have used both a long-pulse gryotron ({approximately}200 kW, {approximately}0.1s) and a pulsed Free Electron Laser (FEL) as microwave sources. Gyrotron experiments with power densities corresponding to 4 MW m{sup {minus}3}. A far infrared (FIR) polarimeter measured peaking of plasma current profiles in some discharges during the ECRH pulse. During high-power single-pulse FEL experiments, single-pass microwave !transmission measurements show nonlinear effects; i.e., higher transmission than predicted by linear theory. A corrugated-wall duct was used in the tokamak port to increase the gradient of the parallel refractive index n{sub parallel} of the incident wave, and increased absorption was observed. Evidence of electron tail heating during FEL pulses was observed on soft x-ray and ECE diagnostics. These results are in agreement with predictions of nonlinear theory; extrapolation of this theory to reactor-like conditions indicates efficient absorption and heating. A Laser Assisted Particle Probe Spectroscopy (LAPPS) diagnostic provided estimates of the vacuum electric field of the FEL which were consistent with the measured power. Multiple pulse operation of the ETA-II accelerator for the FEL has also been demonstrated, indicating the feasibility of high-average power FEL operation.

  3. The study of acceptance and the transmission efficiency of separated sector cyclotron

    Directory of Open Access Journals (Sweden)

    Li Xiaoni

    2015-01-01

    Full Text Available In this paper we present the study of the transversal and longitudinal acceptance and the transmission efficiency in the injection, acceleration, and extraction systems in the separated sector cyclotron of the heavy ion research facility in Lanzhou, China. The study of cyclotron acceptance is done for 238U36+ with energy of 97 MeV/u and for 70Zn10+ with energy of 5.62 MeV/u under the theoretical isochronous and real magnetic field distribution. From the simulation results it can be seen that the transmission efficiency and the acceptances of separated sector cyclotron can be improved by redesign the curvature of MSI3 deflector or by introducing the magnet shim in MSI3 deflector region to change the distribution of the inner magnetic field. [Projekat Ministarstva nauke Republike Srbije, br. OI-171018

  4. Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector

    Science.gov (United States)

    Ashtari Esfahani, A.; Böser, S.; Claessens, C.; de Viveiros, L.; Doe, P. J.; Doeleman, S.; Fertl, M.; Finn, E. C.; Formaggio, J. A.; Guigue, M.; Heeger, K. M.; Jones, A. M.; Kazkaz, K.; LaRoque, B. H.; Machado, E.; Monreal, B.; Nikkel, J. A.; Oblath, N. S.; Robertson, R. G. H.; Rosenberg, L. J.; Rybka, G.; Saldaña, L.; Slocum, P. L.; Tedeschi, J. R.; Thümmler, T.; Vandevender, B. A.; Wachtendonk, M.; Weintroub, J.; Young, A.; Zayas, E.

    2017-09-01

    The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron’s Lorentz factor, this is also a measurement of the electron’s energy. In order to demonstrate the viability of this technique, we have assembled and successfully operated a prototype system, which uses a rectangular waveguide to collect the cyclotron radiation from internal conversion electrons emitted from a gaseous 83m Kr source. Here we present the main design aspects of the first phase prototype, which was operated during parts of 2014 and 2015. We will also discuss the procedures used to analyze these data, along with the features which have been observed and the performance achieved to date.

  5. Optimized feed-forward neural-network algorithm trained for cyclotron-cavity modeling

    Science.gov (United States)

    Mohamadian, Masoumeh; Afarideh, Hossein; Ghergherehchi, Mitra

    2017-01-01

    The cyclotron cavity presented in this paper is modeled by a feed-forward neural network trained by the authors’ optimized back-propagation (BP) algorithm. The training samples were obtained from simulation results that are for a number of defined situations and parameters and were achieved parametrically using MWS CST software; furthermore, the conventional BP algorithm with different hidden-neuron numbers, structures, and other optimal parameters such as learning rate that are applied for our purpose was also used here. The present study shows that an optimized FFN can be used to estimate the cyclotron-model parameters with an acceptable error function. A neural network trained by an optimized algorithm therefore shows a proper approximation and an acceptable ability regarding the modeling of the proposed structure. The cyclotron-cavity parameter-modeling results demonstrate that an FNN that is trained by the optimized algorithm could be a suitable method for the estimation of the design parameters in this case.

  6. Absorption and emission of extraordinary-mode electromagnetic waves near cyclotron frequency in nonequilibrium plasmas

    Science.gov (United States)

    Wu, C. S.; Lin, C. S.; Wong, H. K.; Tsai, S. T.; Zhou, R. L.

    1981-01-01

    An investigation is presented of two cases: (1) weakly relativistic electrons with a loss-cone type distribution, and (2) electrons with a drift velocity parallel to the ambient magnetic field. Numerical computations are given for physical parameters close to those in the polar region of the earth magnetosphere and laboratory experiments, with attention to the fast extraordinary-mode radiation whose frequency is near that of the electron cyclotron frequency. The fast extraordinary mode can escape from a strong field region to the weaker field region and may therefore be measured outside the plasma. It is found that the X mode radiation can be amplified by means of a cyclotron maser effect when the electrons have a loss-cone distribution, and it is concluded that, when the electron energy is sufficiently high, the X mode cutoff frequency may be lower than the cyclotron frequency.

  7. Differentiating Fragmentation Pathways of Cholesterol by Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    Science.gov (United States)

    van Agthoven, Maria A; Barrow, Mark P; Chiron, Lionel; Coutouly, Marie-Aude; Kilgour, David; Wootton, Christopher A; Wei, Juan; Soulby, Andrew; Delsuc, Marc-André; Rolando, Christian; O'Connor, Peter B

    2015-12-01

    Two-dimensional Fourier transform ion cyclotron resonance mass spectrometry is a data-independent analytical method that records the fragmentation patterns of all the compounds in a sample. This study shows the implementation of atmospheric pressure photoionization with two-dimensional (2D) Fourier transform ion cyclotron resonance mass spectrometry. In the resulting 2D mass spectrum, the fragmentation patterns of the radical and protonated species from cholesterol are differentiated. This study shows the use of fragment ion lines, precursor ion lines, and neutral loss lines in the 2D mass spectrum to determine fragmentation mechanisms of known compounds and to gain information on unknown ion species in the spectrum. In concert with high resolution mass spectrometry, 2D Fourier transform ion cyclotron resonance mass spectrometry can be a useful tool for the structural analysis of small molecules. Graphical Abstract ᅟ.

  8. Magnetic field calculation for a 13 MeV PET cyclotron

    CERN Document Server

    Yang, W Y; Oh, S; Chai, J S; Ha, J H

    1999-01-01

    A design study of the main magnet for a 13 MeV cyclotron has been carried out in a joint collaboration between the Korea Cancer Center Hospital (KCCH) and POSTECH. A maximum energy of 13 MeV has been chosen to produce radioisotopes such as /sup 18/F. There are four magnet sectors, each with radial-ridged shape. Maximum magnetic fields are 1.85 T and 0.48 T at hill and valley centers, respectively. The total size of the cyclotron is less than 2 m in diameter. The program TOSCA has been utilized for the field calculation and optimization. In this paper, we describe design parameters of the 13 MeV PET cyclotron, with emphasis on the magnetic field shape and the beam optics calculation. (3 refs).

  9. Experiments on ion cyclotron damping at the deuterium fourth harmonic in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Pinsker, R. I. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Baity, F. W. [Oak Ridge National Laboratory, Oak Ridge, Tennessee (United States); Bernabei, S. [Princeton Plasma Physics Laboratory, Princeton, New Jersey (United States); Greenough, N. [Princeton Plasma Physics Laboratory, Princeton, New Jersey (United States); Heidbrink, W. W. [University of California, Irvine, California (United States); Mau, T. K. [University of California, San Diego, California (United States); Petty, C. C. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Porkolab, M. [Massachusetts Institute of Technology, Cambridge, Massachusetts (United States)

    1999-09-20

    Absorption of fast Alfven waves by the energetic ions of an injected beam is evaluated in the DIII-D tokamak. Ion cyclotron resonance absorption at the fourth harmonic of the deuteron cyclotron frequency is observed with deuterium neutral beam injection (f=60 MHz, B{sub T}=1.9 T). Enhanced D-D neutron rates are evidence of absorption at the Doppler-shifted cyclotron resonance. Characteristics of global energy confinement provide further proof of substantial beam acceleration by the rf. In many cases, the accelerated deuterons cause temporary stabilization of the sawtooth (''monster sawteeth''), at relatively low rf power levels of {approx}1 MW. (c) 1999 American Institute of Physics.

  10. Topological model of composite fermions in the cyclotron band generator picture: New insights

    Science.gov (United States)

    Staśkiewicz, Beata

    2018-03-01

    A combinatorial group theory in the braid groups is correlated with the unusual "anyon" statistic of particles in 2D Hall system in the fractional quantum regime well. On this background has been derived cyclotron band generator as a modification and generalization band generator, first established to solve the word and conjugacy problems in the braid group terms. Topological commensurability condition has been embraced by canonical factors - like, based on the concept of parallel descending cycles. Owing to this we can mathematically capture the general hierarchy of correlated states in the lowest Landau level, describing the fractional quantum Hall effect hierarchy, in terms of cyclotron band generators, especially for those being beyond conventional composite fermions model. It has been also shown that cyclotron braid subgroups, developed for interpretation of Laughlin correlations, are a special case of the right-angled Artin groups.

  11. Improving cancer treatment with cyclotron produced radionuclides. Comprehensive progress report, February 1, 1990--January 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M. Finn, R.D.

    1992-08-04

    This report describes the author`s continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program has 3 interactive components: Radiochemistry /Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section under the DOE grant during the 1989--1992 grant period, will be employed in the Pharmacology and Immunology sections of the DOE grant during the 1992--1995 grant period. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  12. A cyclotron isotope production facility designed to maximize production and minimize radiation dose

    Science.gov (United States)

    Dickie, W. J.; Stevenson, N. R.; Szlavik, F. F.

    1993-06-01

    Continuing increases in requirements from the nuclear medicine industry for cyclotron isotopes is increasing the demands being put on an aging stock of machines. In addition, with the 1990 recommendations of the ICRP publication in place, strict dose limits will be required and this will have an effect on the way these machines are being operated. Recent advances in cyclotron design combined with lessons learned from two decades of commercial production mean that new facilities can result in a substantial charge on target, low personnel dose, and minimal residual activation. An optimal facility would utilize a well engineered variable energy/high current H - cyclotron design, multiple beam extraction, and individual target caves. Materials would be selected to minimize activation and absorb neutrons. Equipment would be designed to minimize maintenance activities performed in high radiation fields.

  13. Comment on the determination of Fermi-liquid parameters from cyclotron-wave measurements using empirical procedures

    DEFF Research Database (Denmark)

    Gordon, R A; Frandsen, J.B.

    1978-01-01

    The application of empirical procedures is shown to lead to a number of ambiguities or errors in the determination of cyclotron-wave dispersion curves. As a result of such ambiguities or errors, it is pointed out that the presently quoted values of the Fermi-liquid parameters {Ai}, i≥2, obtained...... from cyclotron-wave dispersion curves, can not be considered reliable....

  14. [Decommissioning of the medical cyclotron in National Center of Neurology and Psychiatry].

    Science.gov (United States)

    Ito, Kimiteru; Nakata, Yasuhiro; Matsuda, Hiroshi; Sato, Noriko

    2011-05-01

    In Japan, positron emission tomography has prevailed as a useful procedure for detecting malignancy, myocardial viability, and epileptic foci. Consequently, compact medical cyclotrons have been installed in many hospitals. However, reports about the dismantling or decommissioning of compact medical cyclotrons are rare. This report describes the series of steps involved in the decommissioning of a compact medical cyclotron that had been used to produce radioactively tagged substances over a period of fifteen years at the National Center of Neurology and Psychiatry in Japan. Additionally, this report describes the manner in which the radioactive waste was disposed. The plan to decommission the cyclotron was comprised of three phases: a preliminary survey, the dismantling work, and a reports after the dismantling. We complied with the guidelines for the disposal of radioactive waste published by the Ministry of Education, Culture, Sports, Science and Technology. The most radioactive material was the vacuuming foil used in the window of the target chamber, with a dose rate of 17 microSv/h (gamma rays) and 20 x 10(3) cpm (beta rays). The detected radionuclides were mainly 22Na, 57Co, 60Co and 65Zn. The total numbers of radioactive waste containers were thirteen 200 l containers and one 50 l container. We suspect that the long shutdown period of the cyclotron (more than one year) contributed to the decay of the radioactive waste because the amount of containers was smaller than the initial estimation. The shutdown period of a cyclotron may play a significant role in reducing the amount of radioactive waste.

  15. Biomedical research with cyclotron produced radionuclides. Progress report, October 1, 1977--September 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Laughlin, J.S.; Benua, R.S.; Tilbury, R.S.; Bigler, R.E.

    1978-09-30

    Progress is reported on biomedical studies using cyclotron-produced /sup 18/F, /sup 15/O, /sup 11/C, /sup 13/N, /sup 52/Fe, /sup 38/K, /sup 206/Bi, /sup 73/Se, /sup 53/Co, and /sup 43/K. The following research projects are described: tumor detection and diagnosis; neurological studies; radiopharmaceutical development; /sup 38/K as an indicator of blood flow to the myocardium; dosimetry for internally deposited isotopes in animals and man; cyclotron development; positron tomographic imaging with the TOKIM System; and review of positron emission transaxial tomograph instruments. (HLW)

  16. First results of electron cyclotron emission measurements at the GDT magnetic mirror

    CERN Document Server

    Shalashov, A G; Gospodchikov, E D; Lubyako, L V; Yakovlev, D V; Bagryansky, P A

    2016-01-01

    This paper summarizes the results of experiments on electron cyclotron emission (ECE) measurements at the fundamental harmonic recently performed at the axially symmetric magnetic mirror device GDT (Budker Institute, Novosibirsk). New ECE diagnostics is installed to facilitate the successful electron cyclotron resonance heating experiment and operates in the vicinity of the heating frequency of 54.5 GHz. Besides expected emission of thermal electrons, a clearly resolved non-thermal ECE is observed indicating the presence of suprathermal electrons driven by high-power microwave heating. The particulars of plasma emission are studied experimentally in a broad range of discharge scenarios.

  17. Neutron transport calculation for Activation Evaluation for Decommissioning of PET cyclotron Facility

    Science.gov (United States)

    Nobuhara, Fumiyoshi; Kuroyanagi, Makoto; Masumoto, Kazuyoshi; Nakamura, Hajime; Toyoda, Akihiro; Takahashi, Katsuhiko

    2017-09-01

    In order to evaluate the state of activation in a cyclotron facility used for the radioisotope production of PET diagnostics, we measured the neutron flux by using gold foils and TLDs. Then, the spatial distribution of neutrons and induced activity inside the cyclotron vault were simulated with the Monte Calro calculation code for neutron transport and DCHAIN-SP for activation calculation. The calculated results are in good agreement with measured values within factor 3. Therefore, the adaption of the advanced evaluation procedure for activation level is proved to be important for the planning of decommissioning of these facilities.

  18. Cyclotron resonance in InAs/GaSb heterostructure in inclined magnetic field

    CERN Document Server

    Greshnov, A A; Vasilev, Yu B; Suchalkin, S D; Meltser, B Y; Ivanov, S V; Kopev, P S

    2002-01-01

    The mechanism of splitting the cyclotron resonance line in the InAs/GaSb heterostructure in the inclined magnetic field is experimentally and theoretically studied. It is shown that the electrons and holes mixing in leads to the anticrossing Landau levels and consequently to the cyclotron resonance line splitting. Splitting in the case of the inclined magnetic field was not observed which is explained by damping the electrons and holes states mixing in on the account of originating the additional barrier for the electrons and holes by availability of the magnetic field longitudinal constituent

  19. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  20. Solid targets for production of radioisotopes with cyclotron; Blancos solidos para produccion de radioisotopos con ciclotron

    Energy Technology Data Exchange (ETDEWEB)

    Paredes G, L.; Balcazar G, M. [Instituto Nacional de Investigaciones Nucleares, Direccion de Investigacion Tecnologica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The design of targets for production of radioisotopes and radiopharmaceuticals of cyclotron to medical applications requires a detailed analysis of several variables such as: cyclotron operation conditions, choice of used materials as target and their physicochemical characteristics, activity calculation, the yielding of each radioisotope by irradiation, the competition of nuclear reactions in function of the projectiles energy and the collision processes amongst others. The objective of this work is to determine the equations for the calculation for yielding of solid targets at the end of the proton irradiation. (Author)

  1. Unidirectional stripping extraction from a cyclotron which accelerates light as well as heavy ions

    Directory of Open Access Journals (Sweden)

    Jasna L. Ristić-Djurović

    2003-03-01

    Full Text Available The VINCY Cyclotron (VINča CYclotron is a multipurpose machine intended to accelerate light as well as heavy ions. To extract heavy ions with low energy and light ions an extraction system with stripping foil is used. Heavy ions with high energy will be extracted by means of an electrostatic deflector. The former extraction system will be manufactured and used first. The proposed unidirectional stripping extraction system is the optimal balance between the placement of the extraction line and the required diversity and quality of the extracted beam. The available range of extraction directions is set by geometry limitations.

  2. A simple thick target for production of 89Zr using an 11 MeV cyclotron

    Science.gov (United States)

    Link, Jeanne M.; Krohn, Kenneth A.; O’Hara, Matthew J.

    2017-01-01

    The growing interest but limited availability of 89Zr for PET led us to test targets for the 89Y(p,n) reaction. The goal was an easily constructed target for an 11 MeV Siemens cyclotron. Yttrium foils were tested at different thicknesses, angles and currents. A 90° foil tolerated 41 μA without damage and produced ~800 MBq/h, > 20 mCi, an amount adequate for radiochemistry research and human doses in a widely available accelerator. This method should translate to higher energy cyclotrons. PMID:28187357

  3. The electrostatic ion-cyclotron instability-a two-dimensional potential relaxation instability

    DEFF Research Database (Denmark)

    Popa, G.; Schrittwieser, R.; Juul Rasmussen, Jens

    1985-01-01

    An experimental investigation shows that the electrostatic ion-cyclotron instability, driven by an electron current to a positively biased collector, is accompanied by strong coherent two-dimensional fluctuations of the plasma potential in front of the collector. These results suggest that this i......An experimental investigation shows that the electrostatic ion-cyclotron instability, driven by an electron current to a positively biased collector, is accompanied by strong coherent two-dimensional fluctuations of the plasma potential in front of the collector. These results suggest...

  4. The influence of the edge density fluctuations on electron cyclotron wave beam propagation in tokamaks

    DEFF Research Database (Denmark)

    Bertelli, N.; Balakin, A.A.; Westerhof, E.

    2010-01-01

    A numerical analysis of the electron cyclotron (EC) wave beam propagation in the presence of edge density fluctuations by means of a quasi-optical code [Balakin A. A. et al, Nucl. Fusion 48 (2008) 065003] is presented. The effects of the density fluctuations on the wave beam propagation are estim......A numerical analysis of the electron cyclotron (EC) wave beam propagation in the presence of edge density fluctuations by means of a quasi-optical code [Balakin A. A. et al, Nucl. Fusion 48 (2008) 065003] is presented. The effects of the density fluctuations on the wave beam propagation...

  5. Medium to large scale radioisotope production for targeted radiotherapy using a small PET cyclotron

    DEFF Research Database (Denmark)

    Thisgaard, Helge; Jensen, Mikael; Elema, Dennis Ringkjøbing

    2011-01-01

    In recent years the use of radionuclides in targeted cancer therapy has increased. In this study we have developed a high-current solid target system and demonstrated that by the use of a typical low-energy medical cyclotron, it is possible to produce tens of GBq's of many unconventional radionuc......In recent years the use of radionuclides in targeted cancer therapy has increased. In this study we have developed a high-current solid target system and demonstrated that by the use of a typical low-energy medical cyclotron, it is possible to produce tens of GBq's of many unconventional...

  6. ROKCY-12 (KCCH PET-dedicated cyclotron): main features and improvements

    Energy Technology Data Exchange (ETDEWEB)

    Chai, J. S.; Kim, Y. S.; Yang, Y. T.; Jung, I. S.; Hong, S. S.; Lee, M. Y.; Jang, H. S.; Kim, J. H. [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2002-07-01

    In this paper, we describe the development of 13 MeV cyclotron (ROKCY-12) that can be used for a Position Emission Tomography(PET) purpose. This cyclotron with a maximum beam energy of 13 MeV can produce radio isotopes especially {sup 18}F which has a relatively short half lifetime of 110 minutes. First, we show the beam characteristics can be used to carry out the operation of ROCKY-12. Based on this, a computer program has been developed to determine main cyclotron parameters such as cyclotron magnet, RF system, ion source, vacuum system and other cyclotron operation parameters. And then we show the result of design and manufacturing feature of ROKCY-12. By using this design program, one can determines magnet yoke geometry and the average magnetic fields etc. And then the three-dimensional computer program OPERA-3D has been invoked to determine magnet pole tips. Validity of the design can be seen by investigating magnetic fields, radial and vertical focusing frequencies as a function of the beam energy. In this paper, we show the results of cyclotron beam by ROCKY-12. We designed 77.3 MHz RF system and ion source system. We tested RF resonance each coupling methods. We show the result of RF design and prototype operation. Developed ion source is PIG type. We described our design methods and implementation. We report the result of getting negative hydrogen ion. Cyclotron controller asks inputs of every sensor and output of every instrument for notifying current condition to operator. It has independent controllers, for example DC power supply, vacuum system, beam profile system, beam extraction system, RF system, ion source, cooling unit and so on. Basically, each control system uses RS-485 for communication to main control computer. Consumers reward products and services that feature quality, originality, a distinct personality and charm. The International Standardization Organization (ISO) requires, as its mission, that we achieve competitive superiority by

  7. Neutron transport calculation for Activation Evaluation for Decommissioning of PET cyclotron Facility

    Directory of Open Access Journals (Sweden)

    Nobuhara Fumiyoshi

    2017-01-01

    Full Text Available In order to evaluate the state of activation in a cyclotron facility used for the radioisotope production of PET diagnostics, we measured the neutron flux by using gold foils and TLDs. Then, the spatial distribution of neutrons and induced activity inside the cyclotron vault were simulated with the Monte Calro calculation code for neutron transport and DCHAIN-SP for activation calculation. The calculated results are in good agreement with measured values within factor 3. Therefore, the adaption of the advanced evaluation procedure for activation level is proved to be important for the planning of decommissioning of these facilities.

  8. Purification of cyclotron-produced {sup 203}Pb for labeling Herceptin

    Energy Technology Data Exchange (ETDEWEB)

    Garmestani, Kayhan [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States); Milenic, Diane E. [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States); Brady, Erik D. [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States); Plascjak, Paul S. [PET Department, Clinical Center, NIH, Bethesda, MD 20892-1002 (United States); Brechbiel, Martin W. [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States)]. E-mail: martinwb@mail.nih.gov

    2005-04-01

    A simple and rapid procedure was developed for the purification of cyclotron-produced {sup 203}Pb via the {sup 203}Tl(d,2n) {sup 203}Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify {sup 203}Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified {sup 203}Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the {sup 203}Pb radioimmunoconjugate were evaluated.

  9. Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2008-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has recently been developed and installed in order to extend the variety and the intensity of ions at the RCNP coupled cyclotron facility. Production of several ions such as O, N, Ar, Kr, etc., is now under development and some of them have already been used for user experiments. For example, highly charged heavy ion beams like (86)Kr(21+,23+) and intense (16)O(5+,6+) and (15)N(6+) ion beams have been provided for experiments. The metal ion from volatile compounds method for boron ions has been developed as well.

  10. Effects of energetic heavy ions on electromagnetic ion cyclotron wave generation in the plasmapause region

    Science.gov (United States)

    Kozyra, J. U.; Cravens, T. E.; Nagy, A. F.; Fontheim, E. G.; Ong, R. S. B.

    1984-01-01

    An expression for electromagnetic ion cyclotron convective growth rates is derived. The derivation of the dispersion relation and convective growth rates in the presence of a multicomponent energetic and cold plasma is presented. The effects that multiple heavy ions in the ring current and cold plasma produce in the growth and propagation characteristics of ion cyclotron waves are explored. Results of growth rate calculations using parameters consistent with conditions in the plasmapause region during the early recovery phase of geomagnetic storms are presented and compared with ground-based and satellite observations of waves in this region. The geophysical implications of the results are discussed.

  11. New Cyclotron Targetry to Enhance F-18 clinical Position Emission Tomography

    Energy Technology Data Exchange (ETDEWEB)

    J. Michael Doster

    2008-12-19

    This project proposes to develop cyclotron targets that produce F-18 for clinical Positron Emission Tomography (PET) at significantly higher rates than that available from current targetry. This production rate of 18F is directly proportional to the beam current. Higher beam currents would result in increased 18F production but would be accompanied by higher heat loads to the target. The beam power available in most commercial cyclotrons exceeds the heat removal capacity of current target technology by a factor of two to four, significantly limiting the production rate of Fluorine-18.

  12. Electron cyclotron emission at the fundamental harmonic in GDT magnetic mirror

    Science.gov (United States)

    Shalashov, A. G.; Solomakhin, A. L.; Gospodchikov, E. D.; Lubyako, L. V.; Yakovlev, D. V.; Bagryansky, P. A.

    2017-08-01

    New electron cyclotron emission (ECE) diagnostics has been installed to facilitate the successful experiment of electron cyclotron plasma heating (ECRH) in a large open magnetic trap GDT at Budker Institute. The particularities of ECE in the vicinity of the ECRH frequency were studied experimentally for a broad range of discharge scenarios. The measured thermal emission has partly validated the existing physical conceptions about microwave plasma heating in the machine. Besides the expected emission of thermal electrons, a clearly resolved non-thermal ECE was observed which unambiguously confirmed the presence of suprathermal electrons driven by high-power microwave heating.

  13. Status report of the multipurpose superconducting electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Ciavola, G.; Gammino, S.; Barbarino, S.; Celona, L.; Consoli, F.; Gallo, G.; Maimone, F.; Mascali, D.; Passarello, S.; Galata, A.; Tinschert, K.; Spaedtke, P.; Lang, R.; Maeder, J.; Rossbach, J.; Koivisto, H.; Savonen, M.; Koponen, T.; Suominen, P.; Ropponen, T.; Barue, C.; Lechartier, M.; Beijers, J. P. M.; Brandenburg, S.; Kremers, H. R.; Vanrooyen, D.; Kuchler, D.; Scrivens, R.; Schachter, L.; Dobrescu, S.; Stiebing, K.

    Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up

  14. LIBO - boosting medical cyclotron facilities for cancer therapy Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    Length : Energy boost : From 62 to 200 MeVAccelerating gradient : 10 MeV/metreAccelerating frequency : 3 GHz Collaboration : CERN, INFN and University of Milan, INFN and University of Naples and TERA foundation Prototype test in 2001 : SC cyclotron Catania

  15. Modelling third harmonic ion cyclotron acceleration of deuterium beams for JET fusion product studies experiments

    DEFF Research Database (Denmark)

    Schneider, M.; Johnson, T.; Dumont, R.

    2016-01-01

    Recent JET experiments have been dedicated to the studies of fusion reactions between deuterium (D) and Helium-3 (3He) ions using neutral beam injection (NBI) in synergy with third harmonic ion cyclotron radio-frequency heating (ICRH) of the beam. This scenario generates a fast ion deuterium tail...

  16. Analysis of Chaperone Complexes by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    NARCIS (Netherlands)

    Geels, R.B.J.

    2008-01-01

    Investigation of methodologies for analyses of noncovalently bound protein assemblies using Fourier transformation ion cyclotron resonance mass spectrometry (FT-ICR-MS) and quadrupole Time-of-Flight (qToF) mass spectrometry. Specifically, the co-chaperonins GroEL and gp31 are used to perform

  17. Study of the Polarization Strategy for Electron Cyclotron Heating Systems on HL-2M

    Science.gov (United States)

    Zhang, F.; Huang, M.; Xia, D. H.; Song, S. D.; Wang, J. Q.; Huang, B.; Wang, H.

    2016-06-01

    As important components integrated in transmission lines of electron cyclotron heating systems, polarizers are mainly used to obtain the desired polarization for highly efficient coupling between electron cyclotron waves and plasma. The polarization strategy for 105-GHz electron cyclotron heating systems of HL-2M tokamak is studied in this paper. Considering the polarizers need high efficiency, stability, and low loss to realize any polarization states, two sinusoidal-grooved polarizers, which include a linear polarizer and an elliptical polarizer, are designed with the coordinate transformation method. The parameters, the period p and the depth d, of two sinusoidal-grooved polarizers are optimized by a phase difference analysis method to achieve an almost arbitrary polarization. Finally, the optimized polarizers are manufactured and their polarization characteristics are tested with a low-power test platform. The experimental results agree well with the numerical calculations, indicating that the designed polarizers can meet the polarization requirements of the electron cyclotron heating systems of HL-2M tokamak.

  18. Destabilization of fast particle stabilized sawteeth in ASDEX Upgrade with electron cyclotron current drive

    DEFF Research Database (Denmark)

    Igochine, V.; Chapman, I.T.; Bobkov, V.

    2011-01-01

    Upgrade for destabilization of fast particle stabilized sawteeth with electron cyclotron current drive (ECCD). It is shown that moderate ECCD from a single gyrotron is able to destabilize the fast particle stabilized sawteeth. A reduction in sawtooth period by about 40% was achieved in first experiments...

  19. The smooth cyclotron line in Her X-1 as seen with NuSTAR

    DEFF Research Database (Denmark)

    Fuerst, Felix; Grefenstette, Brian W.; Staubert, Ruediger

    2013-01-01

    Her X-1, one of the brightest and best studied X-ray binaries, shows a cyclotron resonant scattering feature (CRSF) near 37 keV. This makes it an ideal target for detailed study with the Nuclear Spectroscopic Telescope Array (NuSTAR), taking advantage of its excellent hard X-ray spectral resolution...

  20. Graphical user interface for yield and dose estimations for cyclotron-produced technetium.

    Science.gov (United States)

    Hou, X; Vuckovic, M; Buckley, K; Bénard, F; Schaffer, P; Ruth, T; Celler, A

    2014-07-07

    The cyclotron-based (100)Mo(p,2n)(99m)Tc reaction has been proposed as an alternative method for solving the shortage of (99m)Tc. With this production method, however, even if highly enriched molybdenum is used, various radioactive and stable isotopes will be produced simultaneously with (99m)Tc. In order to optimize reaction parameters and estimate potential patient doses from radiotracers labeled with cyclotron produced (99m)Tc, the yields for all reaction products must be estimated. Such calculations, however, are extremely complex and time consuming. Therefore, the objective of this study was to design a graphical user interface (GUI) that would automate these calculations, facilitate analysis of the experimental data, and predict dosimetry. The resulting GUI, named Cyclotron production Yields and Dosimetry (CYD), is based on Matlab®. It has three parts providing (a) reaction yield calculations, (b) predictions of gamma emissions and (c) dosimetry estimations. The paper presents the outline of the GUI, lists the parameters that must be provided by the user, discusses the details of calculations and provides examples of the results. Our initial experience shows that the proposed GUI allows the user to very efficiently calculate the yields of reaction products and analyze gamma spectroscopy data. However, it is expected that the main advantage of this GUI will be at the later clinical stage when entering reaction parameters will allow the user to predict production yields and estimate radiation doses to patients for each particular cyclotron run.

  1. The smooth cyclotron line in her x-1 as seen with nuclear spectroscopic telescope array

    DEFF Research Database (Denmark)

    Fuerst, Felix; Grefenstette, Brian W.; Staubert, Ruediger

    2013-01-01

    Her X-1, one of the brightest and best studied X-ray binaries, shows a cyclotron resonant scattering feature (CRSF) near 37 keV. This makes it an ideal target for detailed study with the Nuclear Spectroscopic Telescope Array (NuSTAR), taking advantage of its excellent hard X-ray spectral resolution...

  2. Dispersion equations for field-aligned cyclotron waves in axisymmetric magnetospheric plasmas

    Directory of Open Access Journals (Sweden)

    N. I. Grishanov

    2006-03-01

    Full Text Available In this paper, we derive the dispersion equations for field-aligned cyclotron waves in two-dimensional (2-D magnetospheric plasmas with anisotropic temperature. Two magnetic field configurations are considered with dipole and circular magnetic field lines. The main contribution of the trapped particles to the transverse dielectric permittivity is estimated by solving the linearized Vlasov equation for their perturbed distribution functions, accounting for the cyclotron and bounce resonances, neglecting the drift effects, and assuming the weak connection of the left-hand and right-hand polarized waves. Both the bi-Maxwellian and bi-Lorentzian distribution functions are considered to model the ring current ions and electrons in the dipole magnetosphere. A numerical code has been developed to analyze the dispersion characteristics of electromagnetic ion-cyclotron waves in an electron-proton magnetospheric plasma with circular magnetic field lines, assuming that the steady-state distribution function of the energetic protons is bi-Maxwellian. As in the uniform magnetic field case, the growth rate of the proton-cyclotron instability (PCI in the 2-D magnetospheric plasmas is defined by the contribution of the energetic ions/protons to the imaginary part of the transverse permittivity elements. We demonstrate that the PCI growth rate in the 2-D axisymmetric plasmasphere can be significantly smaller than that for the straight magnetic field case with the same macroscopic bulk parameters.

  3. Tomsk Polytechnic University cyclotron as a source for neutron based cancer treatment.

    Science.gov (United States)

    Lisin, V A; Bogdanov, A V; Golovkov, V M; Musabaeva, L I; Sukhikh, L G; Verigin, D A

    2014-02-01

    In this paper we present our cyclotron based neutron source with average energy 6.3 MeV generated during the 13.6 MeV deuterons interactions with beryllium target, neutron field dosimetry, and dosimetry of attendant gamma fields. We also present application of our neutron source for cancer treatment.

  4. Three-wave interaction during electron cyclotron resonance heating and current drive

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Jacobsen, Asger Schou; Hansen, Søren Kjer

    2016-01-01

    Non-linear wave-wave interactions in fusion plasmas, such as the parametric decay instability (PDI) of gyrotron radiation, can potentially hamper the use of microwave diagnostics. Here we report on anomalous scattering in the ASDEX Upgrade tokamak during electron cyclotron resonance heating...

  5. The electrostatic ion-cyclotron instability excited by a current to a strip collector

    DEFF Research Database (Denmark)

    Juul Rasmussen, Jens; Schrittwieser, R.; Skøelv, Å.

    1986-01-01

    The electrostatic ion-cyclotron instability is excited in a single-ended Q-machine by drawing an electron current to a strip collector crossing the entire plasma column. The instability is most easily excited when the widths of the strip is a few ion Larmor radii. The instability is confined within...

  6. Estimation of activity of air in the cyclotron bunker for PET diagnostics

    Directory of Open Access Journals (Sweden)

    Voskanjan Karen Varuzhanovich

    2012-09-01

    Full Text Available The paper presents the results of the estimation of air activation by argon-41 induced by accelerated protons in 18 MeV Cyclotron. It has been demonstrated that activity of air is below significant minimum at proton current of 150 microamps.

  7. Discrete-Spectrum Waves in the Vicinity of Cyclotron Resonance in Silver

    DEFF Research Database (Denmark)

    Henningsen, J. O.

    1970-01-01

    Cyclotron-resonance studies of silver have revealed two additional series of oscillations, one between the fundamental and the second harmonic, the other above the fundamental resonance. These series are caused by the excitation of weakly damped discrete-spectrum waves propagating perpendicular...

  8. Stability of electrostatic ion cyclotron waves in a multi-ion plasma

    Indian Academy of Sciences (India)

    A detailed numerical study, for parameters relevant to comet Halley, shows that the growth rate is dependent on the magnitude of the frequency. The ion cyclotron waves are driven by the electron drift parallel to the magnetic field; the temperature anisotropy of the oxygen ions only slightly enhance the growth rates for small ...

  9. On-line microseparations with Fourier transform ion cyclotron resonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, J.H.; Hofstadler, S.A.; Zhao, Zhongxi; Gale, D.C.; Smith, R.D. [Pacific Northwest Lab., Richland, WA (United States)

    1994-12-31

    The combination of capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI/MS) is a powerful bioanalytical tool. Accurate charge states are readily obtained through high resolution MS techniques such as Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. In this study, the authors examine the practical considerations that were necessary for successful on-line CE-ESI/FTICR MS.

  10. Theory of the Current-Driven Ion Cyclotron Instability in the Bottomside Ionosphere.

    Science.gov (United States)

    1985-11-11

    Davidson, 1972; Aamodt , 1970]. Recent nonlinear numerical simulations [Pritchett et al., 1981; Okuda and Ashour-Abdalla, 1981] of the collisionless ion...Y -.- d-. .-. .--. W REFERENCES Aamodt , R.E., Particle motion in the presence of three dimensional finite amplitude harmonic cyclotron

  11. Simulation on the electronic wave packet cyclotron motion in a Weyl semimetal slab.

    Science.gov (United States)

    Yao, Haibo; Zhu, Mingfeng; Jiang, Liwei; Zheng, Yisong

    2017-04-20

    We perform a numerical simulation on the time evolution of an electronic wave packet in a Weyl semimetal (WSM) slab driven by a magnetic field. We find that the evolution trajectory of the wave packet depends sensitively on its initial spin state. Only with initial spin state identical to that of the Fermi arc state at the surface it localized, does the wave packet evolution demonstrate the characteristic cyclotron orbit of WSM previously predicted from a semiclassical viewpoint. By analyzing the eigen-expansion of the electronic wave packet, we find the chiral Landau levels (LLs) of the WSM slab, as ingredients of the wave packet, to be responsible for establishing the characteristic WSM cyclotron orbit. In contrast, the nonchiral LLs contribute irregular oscillations to the wave packet evolution, going against the formation of a well-defined cyclotron orbit. In addition, the tilted magnetic field does not affect the motion of the electronic wave packet along the Fermi arcs in the momentum space. It does, however, alter the evolution trajectory of the electronic wave packet in real space and spin space. Finally, the energy disalignment of the Weyl nodes results in a 3D cyclotron orbit in real space.

  12. Closure of the single fluid magnetohydrodynamic equations in presence of electron cyclotron current drive

    NARCIS (Netherlands)

    Westerhof, E.; Pratt, J.

    2014-01-01

    In the presence of electron cyclotron current drive (ECCD), the Ohm's law of single fluid magnetohydrodynamics is modified as E + v × B = η(J – J EC). This paper presents a new closure relation for the EC driven current density appearing in this modified Ohm's law. The new relation

  13. Advanced launcher design options for electron cyclotron current drive on ITER based on remote steering

    NARCIS (Netherlands)

    Graswinckel, M. R.; Bongers, W. A.; M.R. de Baar,; van den Berg, M. A.; Denisov, G.; Donne, A. J. H.; Elzendoorn, B. S. Q.; Goede, A. P. H.; Heidinger, R.; Kuzikov, S.; Kruijt, O. G.; Kruizinga, B.; Moro, A.; Poli, E.; Ronden, D. M. S.; Saibene, G.; Thoen, D. J.; Verhoeven, A. G. A.

    2008-01-01

    Electron cyclotron current drive will become the main scheme on ITER for the stabilization of neoclassical tearing modes (NTMs) and the control of sawtooth oscillations. The effectiveness of this scheme forms the basis for the requirements of the ITER Upper Port Launcher. These requirements include

  14. Cyclotron laboratory of the Institute for Nuclear Research and Nuclear Energy

    Science.gov (United States)

    Tonev, D.; Goutev, N.; Georgiev, L. S.

    2016-06-01

    An accelerator laboratory is presently under construction in Sofia at the Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences. The laboratory will use a TR24 type of cyclotron, which provides a possibility to accelerate a proton beam with an energy of 15 to 24 MeV and current of up to 0.4 mA. An accelerator with such parameters allows to produce a large variety of radioisotopes for development of radiopharmaceuticals. The most common radioisotopes that could be produced with such a cyclotron are PET isotopes like: 11C, 13N, 15O, 18F, 124I, 64Cu, 68Ge/68Ga, and SPECT isotopes like: 123I, 111In, 67Ga, 57Co, 99m Tc. Our aim is to use the cyclotron facility for research in the fields of radiopharmacy, radiochemistry, radiobiology, nuclear physics, solid state physics, applied research, new materials and for education in all these fields including nuclear energy. The building of the laboratory will be constructed nearby the Institute for Nuclear Research and Nuclear Energy and the cyclotron together with all the equipment needed will be installed there.

  15. Neutron Beams from Deuteron Breakup at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, M.A.; Ahle, L.; Bleuel, D.L.; Bernstein, L.; Braquest, B.R.; Cerny, J.; Heilbronn, L.H.; Jewett, C.C.; Thompson, I.; Wilson, B.

    2007-07-31

    Accelerator-based neutron sources offer many advantages, in particular tunability of the neutron beam in energy and width to match the needs of the application. Using a recently constructed neutron beam line at the 88-Inch Cyclotron at LBNL, tunable high-intensity sources of quasi-monoenergetic and broad spectrum neutrons from deuteron breakup are under development for a variety of applications.

  16. Ultralow Frequency Waves In Saturn's Magnetosphere: More Than Ion Cyclotron Waves

    Science.gov (United States)

    Crary, Frank; Dols, Vincent; Usanova, Maria; Meeks, Zachary; Simon, Sven

    2017-04-01

    Electromagnetic waves near the oxygen/water group cyclotron frequency are an ubiquitous feature of Saturn's inner magnetosphere. These left-circularly polarized, transverse waves are generated by the anisotropic velocity distribution of recently produced ions, and reflect the ion production rate. The properties and distribution of these emissions have been previous studies and related to the distribution of neutrals in the system (Leisner et al., 2006; Crary et al., 2013; Meeks et al., 2016.) In addition to these waves, other, related mode have been observed by the Cassini spacecraft. The waves near the W+ (water group) cyclotron frequency sometimes have a compressional component and/or accompanying emission the first (2f) harmonic (implying the waves are oblique rather than parallel propagating. Neither of these properties is predicted by the classic theory of wave growth from a ring-beam distribution. In addition, ion cyclotron waves are also observed near the gyrofrequency of a 32 AMU ion, suggesting production of O2+. While observed, O2+ is a very low abundance species outside of 4 Saturn radii, and in the regions where these waves are present. Finally, strong but linearly polarized waves are sometimes observed near the orbit of Enceladus. The association between these waves and W+ ion cyclotron waves is unclear. We will present the measurements of these ULF waves, their frequency of occurrence with respect to position and time, and discuss their implications for plasma production in Saturn's magnetosphere.

  17. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  18. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature

    NARCIS (Netherlands)

    Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.

    2012-01-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron

  19. Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

    NARCIS (Netherlands)

    Beijers, J. P. M.; Mironov, V.

    We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing

  20. Abrupt variation in ion current with biased disk voltage in the electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Taki, GS; Sarma, PR; Chakraborty, DK; Lhandari, RK; Ray, PK; Drentje, AG; Bhandari, R.K.

    The performance of the biased disk in the 6.4 GHz electron cyclotron resonance ion source at VECC, Kolkata was studied at a pressure of similar to 1 X 10(-7) Torr. We observed an abrupt variation of beam current with bias voltage. For low negative bias voltages (from 0 to -5 V) the beam current

  1. Experiments with biased cylinder in electron cyclotron resonance ion source (plenary)

    NARCIS (Netherlands)

    Drentje, AG; Kitagawa, A; Muramatsu, M; Ogawa, H; Sakamoto, Y

    The shape of the magnetic field of an electron cyclotron resonance ion source (ECRIS) gives rise to different particle fluxes (losses) from the plasma to the end plates (mainly diffusion of electrons), and to the side walls (mainly ions). The electron fluxes to the injection end plate can be reduced

  2. Selective minority-ion heating in the afterglow of an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Nadzeyka, A; Meyer, D; Barzangy, F; Drentje, AG; Wiesemann, K

    We report first experimental results on selective minority-ion heating in the afterglow mode of electron cyclotron resonance ion sources in Bochum and at the KVI (Groningen) in mixtures of Ar/O/He and in pure nitrogen. In addition we measured time resolved vacuum ultraviolet-line intensities of

  3. Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Drentje, A. G.; Kitagawa, A.; Muramatsu, M.

    In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms

  4. An overview of control system for the ITER electron cyclotron system

    NARCIS (Netherlands)

    Purohit, D.; Bigelow, T.; Billava, D.; Bonicelli, T.; Caughman, J.; Darbos, C.; Denisov, G.; Gandini, F.; Gassmann, T.; Henderson, M.; Journeux, J. Y.; Kajiwara, K.; Kobayashi, N.; Nazare, C.; Oda, Y.; Omori, T.; Rao, S. L.; Rasmussen, D.; Ronden, D.; Saibene, G.; Sakamoto, K.; Sartori, F.; Takahashi, K.; Temkin, R.

    2011-01-01

    The ITER electron cyclotron (EC) system having capability of up to 26 MW generated power at 170 GHz is being procured by 5 domestic agencies via 10 procurement arrangements. This implies diverse types of equipment and complex interface management. It also places a challenge on control system

  5. Stability of electrostatic ion cyclotron waves in a multi-ion plasma†

    Indian Academy of Sciences (India)

    Abstract. We have studied the stability of the electrostatic ion cyclotron wave in a plasma consisting of isotropic hydrogen ions (H+) and temperature-anisotropic positively. (O+) and negatively (O−) charged oxygen ions, with the electrons drifting parallel to the magnetic field. Analytical expressions have been derived for the ...

  6. Ion cyclotron waves during the Rosetta approach phase: a magnetic estimate of cometary outgassing

    Directory of Open Access Journals (Sweden)

    M. Volwerk

    2013-12-01

    Full Text Available A theoretical model for the ion cyclotron wave generation during the approach phase of Rosetta to 67P/Churyumov–Gerasimenko is presented. For various activity levels of the comet, the crossing of the observational threshold is determined, whose level is derived from the wave power in the undisturbed solar wind near the comet's location during the approach phase at the appropriate frequency. The Giotto flyby at 27P/Grigg–Skjellerup is used to obtain an estimate of how often water-group ion cyclotron waves are observed, and to get insight into the wave forms. At 67P/Churyumov–Gerasimenko one can expect to observe water-group ion cyclotron waves already at a distance of 600 000 km from the nucleus for a nominal outgassing rate of Q = 350 × 1023 molecules per second. The observed first location of cyclotron waves during the Rosetta approach phase will give an indication of the actual outgassing rate of the comet.

  7. Graphical user interface for yield and dose estimations for cyclotron-produced technetium

    Science.gov (United States)

    Hou, X.; Vuckovic, M.; Buckley, K.; Bénard, F.; Schaffer, P.; Ruth, T.; Celler, A.

    2014-07-01

    The cyclotron-based 100Mo(p,2n)99mTc reaction has been proposed as an alternative method for solving the shortage of 99mTc. With this production method, however, even if highly enriched molybdenum is used, various radioactive and stable isotopes will be produced simultaneously with 99mTc. In order to optimize reaction parameters and estimate potential patient doses from radiotracers labeled with cyclotron produced 99mTc, the yields for all reaction products must be estimated. Such calculations, however, are extremely complex and time consuming. Therefore, the objective of this study was to design a graphical user interface (GUI) that would automate these calculations, facilitate analysis of the experimental data, and predict dosimetry. The resulting GUI, named Cyclotron production Yields and Dosimetry (CYD), is based on Matlab®. It has three parts providing (a) reaction yield calculations, (b) predictions of gamma emissions and (c) dosimetry estimations. The paper presents the outline of the GUI, lists the parameters that must be provided by the user, discusses the details of calculations and provides examples of the results. Our initial experience shows that the proposed GUI allows the user to very efficiently calculate the yields of reaction products and analyze gamma spectroscopy data. However, it is expected that the main advantage of this GUI will be at the later clinical stage when entering reaction parameters will allow the user to predict production yields and estimate radiation doses to patients for each particular cyclotron run.

  8. Wide-aperture Nonintercepting Ionization Sensor For Cyclotron Beam Cross-section Control

    CERN Document Server

    Latushkin, S T; Unezhev, V N; Yudin, L

    2004-01-01

    A new construction of beam cross-section ionization sensor (BCSIS) for use with intense beams is proposed. The aperture of the sensor was increased up to 120×120 mm, and its field of vision - up to 60×60 mm. The sensor is functioning at cyclotron with proton beam energy 32 MeV and current 20 mcA.

  9. Low current performance of the Bern medical cyclotron down to the pA range

    Science.gov (United States)

    Auger, M.; Braccini, S.; Ereditato, A.; Nesteruk, K. P.; Scampoli, P.

    2015-09-01

    A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.

  10. A remotely steered millimetre wave launcher for electron cyclotron heating and current drive on ITER

    NARCIS (Netherlands)

    Bongers, W. A.; M. F. Graswinckel,; Goede, A. P. H.; Kasparek, W.; Danilov, I.; Curto, A. F.; M.R. de Baar,; van den Berg, M. A.; Donne, A. J. H.; Elzendoorn, B. S. Q.; Heidinger, R.; Ivanov, P.; Kruijt, O. G.; Lamers, B.; Meier, A.; Piosczyk, B.; Plaum, B.; Ronden, D. M. S.; Thoen, D. J.; Schmid, M.; Verhoeven, A. G. A.

    2010-01-01

    High-power millimetre wave beams employed on ITER for heating and Current drive at the 170 GHz electron cyclotron resonance frequency require agile steering and tight focusing of the beams to suppress neoclassical tearing modes. This paper presents experimental validation of the remote steering (RS)

  11. Radiologic assessment of a self-shield with boron-containing water for a compact medical cyclotron.

    Science.gov (United States)

    Horitsugi, Genki; Fujibuchi, Toshioh; Yamaguchi, Ichiro; Eto, Akihisa; Iwamoto, Yasuo; Hashimoto, Hiromi; Hamada, Seiki; Obara, Satoshi; Watanabe, Hiroshi; Hatazawa, Jun

    2012-07-01

    The cyclotron at our hospital has a self-shield of boron-containing water. The amount of induced radioactivity in the boron-containing water shield of a compact medical cyclotron has not yet been reported. In this study, we measured the photon and neutron dose rates outside the self-shield during cyclotron operation. We estimated the induced radioactivities of the boron-containing water used for the self-shield and then measured them. We estimated the activation of concrete outside the self-shield in the cyclotron laboratory. The thermal neutron flux during cyclotron operation was estimated to be 4.72 × 10(2) cm(-2) s(-1), and the activation of concrete in a cyclotron laboratory was about three orders of magnitude lower than the clearance level of RS-G-1.7 (IAEA). The activity concentration of the boron-containing water did not exceed the concentration limit for radioactive isotopes in drainage in Japan and the exemption level for Basic Safety Standards. Consequently, the boron-containing water is treatable as non-radioactive waste. Neutrons were effectively shielded by the self-shield during cyclotron operation.

  12. A Kinetic Model of Solar Wind Generation by Oblique Ion-cyclotron Waves

    Science.gov (United States)

    Isenberg, Philip A.; Vasquez, Bernard J.

    2011-04-01

    The fast solar wind is generated by extended perpendicular ion heating in coronal holes, but the kinetic mechanism responsible for this heating has not been determined. One long-standing possibility is the resonant-cyclotron dissipation of ion-cyclotron waves, replenished from a turbulent cascade of interacting counter-propagating Alfvén waves. We present results of a kinetic model for proton heating by the quasilinear resonant-cyclotron wave-particle interaction in a coronal hole. The resonant wave spectrum is taken as a power law in wavenumber, uniformly distributed in propagation direction between 0° and 60° with respect to the large-scale radial magnetic field. We obtain the steady-state solution of the kinetic guiding-center equation for the proton distribution in an expanding coronal hole, including the effects of large-scale forces of gravity, charge-separation electric field, Alfvén wave ponderomotive force, and mirror force, along with the small-scale scattering from the wave dissipation. We find that plausible wave intensities can yield reasonable flow speeds and temperatures in the heliocentric radial range between 2 and 6 solar radii. We address the claim in earlier work that dissipation of parallel-propagating ion-cyclotron waves cannot provide enough acceleration and show that claim to be incorrect. We find that the combined action of the large-scale forces and the resonant-cyclotron scattering produces proton distribution functions with a characteristic structure: compressed in the sunward half of velocity space with a high-density shell separate from the origin, and relatively expanded in the anti-sunward half of velocity space. We suggest that qualitatively similar proton distributions would result from the kinetic evolution of any sufficiently effective perpendicular heating mechanism operating in an expanding coronal hole.

  13. Experimental measurement and Monte Carlo assessment of Argon-41 production in a PET cyclotron facility.

    Science.gov (United States)

    Infantino, Angelo; Valtieri, Lorenzo; Cicoria, Gianfranco; Pancaldi, Davide; Mostacci, Domiziano; Marengo, Mario

    2015-12-01

    In a medical cyclotron facility, (41)Ar (t1/2 = 109.34 m) is produced by the activation of air due to the neutron flux during irradiation, according to the (40)Ar(n,γ)(41)Ar reaction; this is particularly relevant in widely diffused high beam current cyclotrons for the production of PET radionuclides. While theoretical estimations of the (41)Ar production have been published, no data are available on direct experimental measurements for a biomedical cyclotron. In this work, we describe a sampling methodology and report the results of an extensive measurement campaign. Furthermore, the experimental results are compared with Monte Carlo simulations performed with the FLUKA code. To measure (41)Ar activity, air samples were taken inside the cyclotron bunker in sealed Marinelli beakers, during the routine production of (18)F with a 16.5 MeV GE-PETtrace cyclotron; this sampling thus reproduces a situation of absence of air changes. Samples analysis was performed in a gamma-ray spectrometry system equipped with HPGe detector. Monte Carlo assessment of the (41)Ar saturation yield was performed directly using the standard FLUKA score RESNUCLE, and off-line by the convolution of neutron fluence with cross section data. The average (41)Ar saturation yield per one liter of air of (41)Ar, measured in gamma-ray spectrometry, resulted to be 3.0 ± 0.6 Bq/µA*dm(3) while simulations gave a result of 6.9 ± 0.3 Bq/µA*dm(3) in the direct assessment and 6.92 ± 0.22 Bq/µA*dm(3) by the convolution neutron fluence-to-cross section. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Production of high intensity 48Ca for the 88-Inch Cyclotron and other updates.

    Science.gov (United States)

    Benitez, J Y; Franzen, K Y; Hodgkinson, A; Lyneis, C M; Strohmeier, M; Thullier, T; Todd, D; Xie, D

    2014-02-01

    Recently the Versatile ECR for NUclear Science (VENUS) ion source was engaged in a 60-day long campaign to deliver high intensity (48)Ca(11+) beam to the 88-Inch Cyclotron. As the first long term use of VENUS for multi-week heavy-element research, new methods were developed to maximize oven to target efficiency. First, the tuning parameters of VENUS for injection into the cyclotron proved to be very different than those used to tune VENUS for maximum beam output of the desired charge state immediately following its bending magnet. Second, helium with no oxygen support gas was used to maximize the efficiency. The performance of VENUS and its low temperature oven used to produce the stable requested 75 eμA of (48)Ca(11+) beam current was impressive. The consumption of (48)Ca in VENUS using the low temperature oven was checked roughly weekly, and was found to be on average 0.27 mg/h with an ionization efficiency into the 11+ charge state of 5.0%. No degradation in performance was noted over time. In addition, with the successful operation of VENUS the 88-Inch cyclotron was able to extract a record 2 pμA of (48)Ca(11+), with a VENUS output beam current of 219 eμA. The paper describes the characteristics of the VENUS tune used for maximum transport efficiency into the cyclotron as well as ongoing efforts to improve the transport efficiency from VENUS into the cyclotron. In addition, we briefly present details regarding the recent successful repair of the cryostat vacuum system.

  15. Cyclotron resonance in InAs/AlSb quantum wells in magnetic fields up to 45 T

    Energy Technology Data Exchange (ETDEWEB)

    Spirin, K. E., E-mail: spirink@ipmras.ru; Krishtopenko, S. S. [Russian Academy of Sciences, Institute for Physics of Microstructures (Russian Federation); Sadofyev, Yu. G. [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation); Drachenko, O. [Laboratoire National des Champs Magn’etiques Intenses (France); Helm, M. [Forschungszentrum Dresden–Rossendorf, Dresden High-Magnetic-Field Laboratory and Institute of Ion-Beam Physics and Materials Research (Germany); Teppe, F.; Knap, W. [GIS-TERALAB Universite Montpellier II, Laboratoire Charles Coulomb UMR CNRS 5221 (L2C) (France); Gavrilenko, V. I. [Russian Academy of Sciences, Institute for Physics of Microstructures (Russian Federation)

    2015-12-15

    Electron cyclotron resonance in InAs/AlSb heterostructures with quantum wells of various widths in pulsed magnetic fields up to 45 T are investigated. Our experimental cyclotron energies are in satisfactory agreement with the results of theoretical calculations performed using the eight-band kp Hamiltonian. The shift of the cyclotron resonance (CR) line, which corresponds to the transition from the lowest Landau level to the low magnetic-field region, is found upon varying the electron concentration due to the negative persistent photoconductivity effect. It is shown that the observed shift of the CR lines is associated with the finite width of the density of states at the Landau levels.

  16. Ion cyclotron waves at unmagnetized bodies: a comparison of Mars, Venus and Titan

    Science.gov (United States)

    Wei, H.; Russell, C. T.; Cowee, M.; Blanco-Cano, X.; Zhang, T.; Dougherty, M. K.

    2009-12-01

    Mars, Venus and Titan do not have appreciable global magnetic fields. Their high-altitude neutral atmospheres are not shielded from being lost to the solar wind and the Saturnian magnetosphere. When the atmospheric hydrogen atoms of Mars and Venus are ionized and picked up by the solar wind, proton cyclotron waves are created from the free energy of the ring-beam distribution of the pick-up ions. At Mars, proton cyclotron waves observed by Mars Global Surveyor extend from the magnetosheath to over 12 Mars radii, with intermittent occurrence and amplitudes slowly varying with distance. The wave occurrence pattern indicates a disk-shaped hydrogen exosphere of Mars with asymmetry in the direction of the interplanetary electric field. Fast neutrals produced by neutralization of the pickup ions can travel across fieldlines to distant regions where they get re-ionized and produce waves far downstream. Thus the top of Mars exosphere extends in a disk to high altitude, with its orientation controlled by the interplanetary magnetic field. At Venus, plasma waves having properties similar to ion cyclotron waves are observed in the solar wind around the planet by Venus Express, with wave frequencies that range from 0.2 to 5.9 times of the proton gyrofrequency. Statistical study shows that the waves with frequency higher than 1.5 times the proton gyrofrequency are not generated locally and are similar to the waves observed at 0.3 AU and 1 AU which appear to be created near the Sun and convected outward with the solar wind. The rest of the waves are mostly magnetically connected to the bow shock, so they are probably generated by particles backstreaming from the shock and propagate out further from the foreshock. At Titan, ion cyclotron waves are not observed although wave generation is expected due to the large pickup rate of hydrocarbon ions at high altitude of Titan. We attempt to understand the lack of ion cyclotron waves at Titan using hybrid simulations. Studying and

  17. The ion cyclotron turbulence generated by a low frequency kinetic Alfvén wave and turbulent heating of ions

    Science.gov (United States)

    Mikhailenko, V. S.; Mikhailenko, V. V.; Lee, Hae June

    2018-01-01

    The ion cyclotron instability driven by a strong kinetic Alfvén wave is investigated as a possible source of anisotropic heating of ions in the sun's corona. We present a novel model of a plasma with coupled inhomogeneous current and shearing flow, which results from the particle's motion in the electric field of the kinetic Alfvén wave of finite wavelength. The investigation is performed employing the non-modal kinetic theory grounded on the shearing mode approach. The solution of the governing linear integral equation for the perturbed potential displays that the flow velocity shear, which for the corona conditions may be above the growth rate of the ion cyclotron instability in the plasma with steady current, changes the exponential growth of the ion cyclotron potential on the power function of time, that impedes the growth of the unstable ion cyclotron wave and reduces the turbulent heating rate of ions across the magnetic field.

  18. A simple and powerful XY-Type current monitor for 30 MeV IPEN/CNEN-SP cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Barcellos, Henrique; Matsuda, Hylton; Sumyia, Luiz Carlos do A.; Junqueira, Fernando de C.; Costa, Osvaldo L. da, E-mail: hbolivei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    A water-cooled XY-type current monitor was designed and built in the Cyclotrons Laboratory of the Nuclear and Energy Research Institute (IPEN). It is a very simple design and easily adaptable to the cyclotron beam lines. Tests were done demonstrating to be an instrument of great assistance in proton beam position along beam transport line and target port. Nowadays the XY-type current monitor has been widely used in {sup 18}F-FDG routine productions, employing irradiation system which were originally designed for productions on 18 MeV cyclotron accelerator only, however, applying the XY-type current monitor the target port may be exchanged between the 30 MeV and 18 MeV cyclotrons and the observed results are in perfect agreement with expected. (author)

  19. Observation of quasi-periodic frequency sweeping in electron cyclotron emission of nonequilibrium mirror-confined plasma

    CERN Document Server

    Viktorov, M E; Mansfeld, D A; Golubev, S V

    2016-01-01

    Chirping frequency patterns have been observed in the electron cyclotron emission from strongly nonequilibrium plasma confined in a table-top mirror magnetic trap. Such patterns are typical for the formation of nonlinear phase space structures in a proximity of the wave-particle resonances of a kinetically unstable plasma, also known as the "holes and clumps" mechanism. Our data provides the first experimental evidence for acting of this mechanism in the electron cyclotron frequency domain.

  20. The high-order cyclotron modes in Fermi liquid of Q2D layered conductors

    Directory of Open Access Journals (Sweden)

    O.V.Kirichenko

    2005-01-01

    Full Text Available The propagation of electromagnetic waves in layered conductors at the presence of an external magnetic field is investigated theoretically. At certain orientations of a magnetic field concerning the layers of the conductor the collisionless absorption is absent and weakly damping collective modes can propagate even under the strong spatial dispersion. In a short-wave limit the existence of electromagnetic waves with frequencies near the cyclotron resonances is possible at an arbitrary orientation of the wave vector with respect to an external magnetic field. We have obtained the spectrum of waves with the frequencies near the cyclotron resonances of high order with regard to the Fermi-liquid interaction of the electrons.

  1. The design of a correlation electron cyclotron emission system on J-TEXT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z. J.; Xiao, Y.; Ma, X. D.; Pan, X. M.; Xiao, J. S. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2015-04-15

    To study the anomalous transport, a correlation electron cyclotron emission (CECE) was planned to be developed on J-TEXT for electron temperature fluctuation measurement. The spectral decorrelation method was employed for the CECE system. It was developed based on the previous 16-channel electron cyclotron emission system. They shared the optical transmission line and mixer. The CECE part consists of 4 channels. Two fixed frequency narrow band filters were used for two channels and two yttrium iron garnet (YIG) filters for the other two channels. To meet the measuring requirement, some tests have been taken for the YIG filters. The results show good performance of the filters. Gaussian optics is used to produce a good poloidal resolution. Wavenumbers resolved by the CECE diagnostic are k{sub θ} ≤ 1.5 rad/cm and k{sub r} ≤ 12 rad/cm. Some preliminary experiment results are also presented in this paper.

  2. Electrostatic Electron Cyclotron Waves Observed by the Plasma Wave Instrument on Board Polar

    Science.gov (United States)

    Menietti, J. D.; Pickett, J. S.; Gurnett, D. A.; Scudder, J. D.

    2001-01-01

    We report the results of an investigation of waves observed by the Polar spacecraft at high altitudes and latitudes and at frequencies just above the cyclotron frequency. These observations are made frequently when the spacecraft is over the polar cap as well as near the dayside cusp and near the nightside auroral region, and observations are made for ratios of plasma frequency to cyclotron frequency, f(sub p)/f(sub c) = 1. Using the six-channel high-frequency waveform receiver (HFWR) on board the spacecraft, which can provide three-axis electric and three-axis magnetic field measurements, we attempt to identify the wavemode of these emissions and investigate possible source mechanisms including low-energy electron beams. We further observe electromagnetic emission associated with upper hybrid waves near and within the plasmasphere. This emission is consistent with both Z and O modes.

  3. Lorentz force in water: evidence that hydronium cyclotron resonance enhances polymorphism.

    Science.gov (United States)

    D'Emilia, E; Giuliani, L; Lisi, A; Ledda, M; Grimaldi, S; Montagnier, L; Liboff, A R

    2015-01-01

    There is an ongoing question regarding the structure forming capabilities of water at ambient temperatures. To probe for different structures, we studied effects in pure water following magnetic field exposures corresponding to the ion cyclotron resonance of H3O(+). Included were measurements of conductivity and pH. We find that under ion cyclotron resonance (ICR) stimulation, water undergoes a transition to a form that is hydroxonium-like, with the subsequent emission of a transient 48.5 Hz magnetic signal, in the absence of any other measurable field. Our results indicate that hydronium resonance stimulation alters the structure of water, enhancing the concentration of EZ-water. These results are not only consistent with Del Giudice's model of electromagnetically coherent domains, but they can also be interpreted to show that these domains exist in quantized spin states.

  4. Cyclotron-produced radioisotopes and their clinical use at the Austin PET Centre

    Energy Technology Data Exchange (ETDEWEB)

    Tochon-Danguy, H.J. [Centre for PET, Melbourne, VIC (Australia). Austin and Repatriation Medical Centre

    1997-12-31

    A Centre for Positron Emission Tomography (PET) has been established within the Department of Nuclear Medicine at the Austin and Repatriation Medical Centre in Melbourne. PET is a non-invasive technique based on the use of biologically relevant compounds labelled with short-lived positron-emitting radionuclides such as carbon-11, nitrogen-13, oxygen-15 and fluorine-18. The basic equipment consists of a medical cyclotron (10 MeV proton and 5 MeV deuteron), six lead-shielded hot cells with associated radiochemistry facilities and a whole body PET scanner. During its first five years of operation, the Melbourne PET Centre, has pursued a strong radiolabelling development program, leading to an ambitious clinical program in neurology, oncology and cardiology. This presentation will describe the basic principles of the PET technique and review the cyclotron-produced radioisotopes and radiopharmaceuticals. Radiolabelling development programs and clinical applications are also addressed. 30 refs., 1 tab., 1 fig.

  5. Sensitive test for ion-cyclotron resonant heating in the solar wind.

    Science.gov (United States)

    Kasper, Justin C; Maruca, Bennett A; Stevens, Michael L; Zaslavsky, Arnaud

    2013-03-01

    Plasma carrying a spectrum of counterpropagating field-aligned ion-cyclotron waves can strongly and preferentially heat ions through a stochastic Fermi mechanism. Such a process has been proposed to explain the extreme temperatures, temperature anisotropies, and speeds of ions in the solar corona and solar wind. We quantify how differential flow between ion species results in a Doppler shift in the wave spectrum that can prevent this strong heating. Two critical values of differential flow are derived for strong heating of the core and tail of a given ion distribution function. Our comparison of these predictions to observations from the Wind spacecraft reveals excellent agreement. Solar wind helium that meets the condition for strong core heating is nearly 7 times hotter than hydrogen on average. Ion-cyclotron resonance contributes to heating in the solar wind, and there is a close link between heating, differential flow, and temperature anisotropy.

  6. Initial operation of the Sherbrooke EBCO 19 MeV cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, K.L.; Cackette, M.; Dehnel, M.P.; Gyles, W.; Johnson, R.R.; Kovac, B.; Popa, I.; Sabaiduc, V.; Watt, R.; Sliwinski, A. [EBCO Technologies Inc., Richmond BC (Canada); Van Lier, J.E. [Sherbrooke Univ., PQ (Canada). Faculte de Medicine

    1999-07-01

    A variable energy TR19 cyclotron built by EBCO Technologies was installed and commissioned at the Centre Hospitalier Universite de Sherbrooke at the end of 1997. This negative ion cyclotron is capable of accelerating a 150 {mu}Amp of protons to over 19 MeV energy and two simultaneous beams of protons of energies between 13 and 19 MeV can be extracted on opposite sides of the magnet. A novel target changer permits the positioning of the variable energy beams, which leave the magnet at different angles, into long gaseous targets. Properties of the beams used for the production of both PET and SPECT isotopes, made possible by the variable energy feature, are discussed. (authors)

  7. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source.

    Science.gov (United States)

    Yang, Y; Sun, L T; Feng, Y C; Fang, X; Lu, W; Zhang, W H; Cao, Y; Zhang, X Z; Zhao, H W

    2014-08-01

    Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

  8. Results of RIKEN superconducting electron cyclotron resonance ion source with 28 GHz.

    Science.gov (United States)

    Higurashi, Y; Ohnishi, J; Nakagawa, T; Haba, H; Tamura, M; Aihara, T; Fujimaki, M; Komiyama, M; Uchiyama, A; Kamigaito, O

    2012-02-01

    We measured the beam intensity of highly charged heavy ions and x-ray heat load for RIKEN superconducting electron cyclotron resonance ion source with 28 GHz microwaves under the various conditions. The beam intensity of Xe(20+) became maximum at B(min) ∼ 0.65 T, which was ∼65% of the magnetic field strength of electron cyclotron resonance (B(ECR)) for 28 GHz microwaves. We observed that the heat load of x-ray increased with decreasing gas pressure and field gradient at resonance zone. It seems that the beam intensity of highly charged heavy ions with 28 GHz is higher than that with 18 GHz at same RF power.

  9. Observation of ion-cyclotron-frequency mode-conversion flow drive in tokamak plasmas.

    Science.gov (United States)

    Lin, Y; Rice, J E; Wukitch, S J; Greenwald, M J; Hubbard, A E; Ince-Cushman, A; Lin, L; Porkolab, M; Reinke, M L; Tsujii, N

    2008-12-05

    Strong toroidal flow (Vphi) and poloidal flow (Vtheta) have been observed in D-3He plasmas with ion cyclotron range of frequencies (ICRF) mode-conversion (MC) heating on the Alcator C-Mod tokamak. The toroidal flow scales with the rf power Prf (up to 30 km/s per MW), and is significantly larger than that in ICRF minority heated plasmas at the same rf power or stored energy. The central Vphi responds to Prf faster than the outer regions, and the Vphi(r) profile is broadly peaked for r/a or =1.5 MW and increases with power (up to 0.7 km/s per MW). The experimental evidence together with numerical wave modeling suggests a local flow drive source due to the interaction between the MC ion cyclotron wave and 3He ions.

  10. Cyclotron production of Ga-68 for human use from liquid targets: From theory to practice

    Science.gov (United States)

    Alves, F.; Alves, V. H.; Neves, A. C. B.; do Carmo, S. J. C.; Nactergal, B.; Hellas, V.; Kral, E.; Gonçalves-Gameiro, C.; Abrunhosa, A. J.

    2017-05-01

    A fully automated system for the production of 68Ga based on commercially available cyclotron liquid target and synthesis modules is described. A solution containing enriched 68Zn dissolved in a nitric solution is irradiated in a Cyclone 18/9 IBA cyclotron leading to the production of up to about 25 GBq of 68Ga. The irradiated solution is transferred to a Synthera synthesis module in which 68Ga is separated and purified with a yield superior to 85 % and where further labelling is achieved with yields no inferior to 70 %. The developed and implemented method presents an improved approach for the production of 68Ga-radiopharmaceuticals suitable for human use, in a process that takes less than 2 hours. This technique represents an economically viable alternative to 68Ge/68Ga generators with improved characteristics.

  11. Van Allen Probes observations of oxygen cyclotron harmonic waves in the inner magnetosphere

    Science.gov (United States)

    Usanova, M.; Malaspina, D.; Jaynes, A. N.; Bruder, R.; Mann, I. R.; Wygant, J. R.; Ergun, R.

    2016-12-01

    Waves with frequencies in the vicinity of the oxygen cyclotron frequency and its harmonics have been regularly observed on the Van Allen Probes satellites during geomagnetic storms. We focus on properties of these waves and present events from the main phase of two storms on November 1, 2012 and March 17, 2013 and associated dropouts of few MeV electron fluxes. They are electromagnetic, in the frequency range 0.5 - several Hz, and amplitude 0.1- a few nT in magnetic and 0.1- a few mV/m in electric field, with both the wave velocity and the Poynting vector directed almost parallel to the background magnetic field. These properties are very similar to those of electromagnetic ion cyclotron (EMIC) waves, which are believed to contribute to loss of ring current ions and radiation belt electrons and therefore can be also important for inner magnetosphere dynamics.

  12. Gamma ray facilities at the University of Maryland cyclotron. [data acquisition and radiation measurement

    Science.gov (United States)

    Hornyak, W. F.

    1978-01-01

    A special beam line was set up in a separate shielded experimental room to provide a low background station for gamma-ray measurements at the University of Maryland cyclotron. The transmitted beam leaving the target is gathered in by a magnetic quadrupole lens located 1.8 m further downstream and focused on a Faraday cup located on the far side of the 2.5 m thick concrete shielding wall of the experimental room. A software computer program permits timing information ot be obtained using the cyclotron beam fine structure as a time reference for the observed gamma-ray events. Measurements indicate a beam fine structure width of less than 1.2 nanoseconds repeated, for example, in the case of 140 MeV alpha particles every 90 nanoseconds. Twelve contiguous time channels of adjustable width may be set as desired with reference to the RF signal. This allows the creation of 12 separate 8192 channel analyzers.

  13. Understanding the bursty electron cyclotron emission during a sawtooth crash in the HT-7 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Li, Erzhong, E-mail: rzhonglee@ipp.ac.cn; Hu, Liqun; Chen, Kaiyun [Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031 (China)

    2014-01-15

    Bursts in electron cyclotron emission (ECE) were observed during sawtooth crashes in HT-7 in discharges with ion cyclotron resonance heating injected near the q = 1 rational surface (q is the safety factor). The local ECE measurement indicated that the bursty radiation is only observed on channels near but a little away outward from the q = 1 magnetic surface. In conjunction with the soft x-ray tomography analysis, it was determined that, for the first time, only a compression process survives in the later stage of fast magnetic reconnection but before prompt heat transport. The compression enhanced the electron radiation temperature, the increased amplitude of which agreed well with the estimation according to a kinetic compression theory model [R. J. Hastie and T. C. Hender, Nucl. Fusion 28, 585 (1988)]. This paper presents the experimental evidence that there indeed exists a transient compression phase which results in the bursty ECE radiation during a sawtooth crash.

  14. Understanding the bursty electron cyclotron emission during a sawtooth crash in the HT-7 tokamak

    Science.gov (United States)

    Li, Erzhong; Hu, Liqun; Chen, Kaiyun

    2014-01-01

    Bursts in electron cyclotron emission (ECE) were observed during sawtooth crashes in HT-7 in discharges with ion cyclotron resonance heating injected near the q = 1 rational surface (q is the safety factor). The local ECE measurement indicated that the bursty radiation is only observed on channels near but a little away outward from the q = 1 magnetic surface. In conjunction with the soft x-ray tomography analysis, it was determined that, for the first time, only a compression process survives in the later stage of fast magnetic reconnection but before prompt heat transport. The compression enhanced the electron radiation temperature, the increased amplitude of which agreed well with the estimation according to a kinetic compression theory model [R. J. Hastie and T. C. Hender, Nucl. Fusion 28, 585 (1988)]. This paper presents the experimental evidence that there indeed exists a transient compression phase which results in the bursty ECE radiation during a sawtooth crash.

  15. Spin-orbit splitting of the cyclotron resonance in GaAs

    Science.gov (United States)

    Tonello, P.; Lipparini, E.

    2004-08-01

    We have studied the relevance of spin-orbit coupling to the splitting of the cyclotron resonance of electron space-charge layers in GaAs recently observed by Manger [Phys. Rev. B 63, 121203R (2001)]. We show that the spin-orbit interaction couples density and spin-density excitations in the long-wavelength limit and is able to explain all the features observed in the experiment.

  16. SPES: A new cyclotron-based facility for research and applications with high-intensity beams

    Science.gov (United States)

    Maggiore, M.; Campo, D.; Antonini, P.; Lombardi, A.; Manzolaro, M.; Andrighetto, A.; Monetti, A.; Scarpa, D.; Esposito, J.; Silvestrin, L.

    2017-06-01

    In 2016, Laboratori Nazionali di Legnaro (Italy) started the commissioning of a new accelerator facility based on a high-power cyclotron able to deliver proton beams up to 70 MeV of energy and 700 μA current. Such a machine is the core of the Selective Production of Exotic Species (SPES) project whose main goal is to provide exotics beam for nuclear and astrophysics research and to deliver high-intensity proton beams for medical applications and neutrons generator.

  17. Cyclotron production of no-carrier-added palladium-103 by bombardment of rhodium-103 target.

    Science.gov (United States)

    Chunfu, Z; Yongxian, W; Yongping, Z; Xiuli, Z

    2001-10-01

    Electroplated rhodium foil was employed as the target for cyclotron production of palladium-103. An electrodissolution apparatus was found better than other dissolution methods in terms of personnel shielding and palladium-103 yield. The ion-exchange column chromatography method was simple and effective for the purification of palladium-103 and the final stripping agent of NH4Cl + NH3(1:1) was more efficient than other agents.

  18. A real-time intercepting beam-profile monitor for a medical cyclotron

    Science.gov (United States)

    Hendriks, C.; Uittenbosch, T.; Cameron, D.; Kellogg, S.; Gray, D.; Buckley, K.; Schaffer, P.; Verzilov, V.; Hoehr, C.

    2013-11-01

    There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

  19. Preliminary production of 211At at the Texas A&M University Cyclotron Institute.

    Science.gov (United States)

    Martin, Thomas Michael; Bhakta, Vihar; Al-Harbi, Abeer; Hackemack, Michael; Tabacaru, Gabriel; Tribble, Robert; Shankar, Sriram; Akabani, Gamal

    2014-07-01

    A feasibility study for the production of the alpha particle-emitting radionuclide At was performed at the Texas A&M University Cyclotron Institute as part of the Interdisciplinary Radioisotope Production and Radiochemistry Program. The mission of this program centers upon the production of radionuclides for use in diagnostic and therapeutic nuclear medicine with the primary focus on development of novel therapeutic strategies. As a first step in establishing this program, two goals were outlined: (i) verify production of At and compare results to published data, and (ii) evaluate shielding and radiological safety issues for large-scale implementation using an external target. The radionuclide At was produced via the Bi (α, 2n) At reaction using the K500 cyclotron. Two experiments were conducted, using beam energies of 27.8 MeV and 25.3 MeV, respectively. The resulting yields for At were found to be 36.0 MBq μA h and 12.4 MBq μA h, respectively, which fall within the range of published yield data. Strategies for increasing absolute yield and production efficiency were also evaluated, which focused chiefly on using a new target designed for use with the K150 cyclotron, which will enable the use of a higher beam current. Finally, neutron and gamma dose rates during production were evaluated by using the Monte Carlo code MCNPX. It was determined that a simple structure consisting of 4-in thick borated polyethylene will reduce the neutron dose rate within the cyclotron production vault by approximately a factor of 2, thereby decreasing activation of equipment.

  20. Parametric decay instability of an obliquely propagating ordinary wave in the electron cyclotron frequency range

    Science.gov (United States)

    Gusakov, E. Z.; Popov, A. Yu.

    2018-01-01

    The possibility of the low-power-threshold parametric decay of an obliquely propagating ordinary wave to an upper hybrid wave and a low-hybrid wave is analysed under conditions of nonmonotonic plasma density profile in a magnetic trap. The instability threshold and growth rate are derived explicitly. The analytical results are illustrated under the conditions typical of the ordinary mode fundamental electron cyclotron resonance heating harmonic experiments at the FTU tokamak.

  1. A real-time intercepting beam-profile monitor for a medical cyclotron.

    Science.gov (United States)

    Hendriks, C; Uittenbosch, T; Cameron, D; Kellogg, S; Gray, D; Buckley, K; Schaffer, P; Verzilov, V; Hoehr, C

    2013-11-01

    There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

  2. submitter Development of a Superconducting Magnet for a Compact Cyclotron for Radioisotope Production

    CERN Document Server

    Garcia-Tabares, Luis; Calero, Jesus; Gutierrez, Jose L; Munilla, Javier; Obradors, Diego; Perez, Jose M; Toral, Fernando; Iturbe, Rafael; Minguez, Leire; Gomez, Jose; Rodilla, Elena; Bajko, Marta; Michels, Matthias; Berkowitz, Daniel; Haug, Friedrich

    2016-01-01

    The present paper describes the development process of a low critical temperature superconducting magnet to be installed in a compact cyclotron producing single-dose radioisotopes for clinical and preclinical applications. After a brief description of the accelerator, the magnet development process is described, starting from the magnetic, mechanical, quench, and thermal calculations, continuing with the designing process, particularly the support structure of the magnet and the cryogenic supply system, to finish with the fabrication and the first tests than have been performed.

  3. The hydraulic lifting system for the main magnets of CYCIAE-30 cyclotron

    CERN Document Server

    Zhao Zhen Lu; Chen Rong Fan; Chu Cheng Jie

    2002-01-01

    The oil-line structure, control system and their working principles of the hydraulic lifting system for the main magnets of CYCIAE-30 cyclotron are introduced. The six years practice proves that the specification of the system matches the requirements: the oil cylinder maximum stroke of 850 mm, the eight slot positioning dowels repositioning accuracy of +-0.01 mm, the two oil cylinders moving in step accuracy of 5-10 mm. The system is safe, reliable and easy to be operated

  4. Use of maze in cyclotron hoppers; Utilizacao de labirinto em bunker de ciclotron

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fernando A.; Alves, Juliano S.; Fochesatto, Cintia; Cerioli, Luciane; Borges, Joao Alfredo; Gonzalez, Delfin; Silva, Daniel C., E-mail: fernandofernandes@biofarmaco.com.br [Delfin Farmacos e Derivados (Biofarmaco Marcadores Moleculares), Lauro de Freitas, BA (Brazil)

    2013-07-01

    Introduction: the increasing number of cyclotrons in Brazil due to constitutional amendment 49 /06 that enabled the production of radiopharmaceuticals with a short half - life by private companies. The radionuclides used for PET - CT require production centers near or within the diagnostic centers. In order to minimize maintenance and operating risks, gaining efficiency, our facility was the first in Brazil to use the access to a cyclotron bunker via maze, rather than armored door stopper type. Materials: the design calculations were based on the Monte Carlo method (MCNP5 - Monte Carlo N-Particletransportcode version 5). At the ends of the labyrinth are installed a door of polyethylene, for thermalization of neutrons, and other of wood for limiting access. Both legs of the maze have wall thickness of 100cm. In inspection Brazilian CNEN realize measures of dose rate for neutrons and gamma 9 points: 7 around the bunker, 1 over the bunker and 1 in the exhaust with the cyclotron operating with maximum load, double beam of 50uA for 2 hours. After commissioning were carried out around the bunker, the following measures: cumulative dose in three months with dosimeters for neutron rate dose with a gas proportional detector type filled with {sup 3}He and polyethylene neutron moderator and dose rate with a Geiger - Mueller detector for gamma radiation. Readings with neutron detectors were classified as background radiation and dose rates were always below the limits established in standard EN 3.01, and the calculation of the predicted regardless of the intensity of irradiation inside the bunker. Conclusion: the use of labyrinths as a way to access the bunkers cyclotron has been shown to be effective as the radiation shielding and efficient by allowing quick and easy access, virtually eliminating the maintenance.

  5. Comparison of Dispersion Model of Magneto-Acoustic Cyclotron Instability with Experimental Observation of 3He Ion Cyclotron Emission on JT-60U

    Science.gov (United States)

    Sumida, Shuhei; Shinohara, Kouji; Ikezoe, Ryuya; Ichimura, Makoto; Sakamoto, Mizuki; Hirata, Mafumi; Ide, Shunsuke

    2017-12-01

    The Magneto-acoustic Cyclotron Instability (MCI) is a possible emission mechanism for Ion Cyclotron Emissions (ICEs). A dispersion model of the MCI driven by a drifting-ring-type ion velocity distribution has been proposed. In this study, the model was compared with the experimental observations of 3He ICEs [ICEs(3He)] on JT-60U. For this purpose, at first, velocity distributions of deuterium-deuterium fusion produced fast 3He ions at the time of an appearance of the ICE(3He) were evaluated by using a fast ion orbit following code under a realistic condition. The calculated distribution at the edge of the plasma on the midplane on the low field side is shown to have an inverted population and strong anisotropy. This distribution can be reasonably approximated by the drifting-ring-type distribution. Next, dispersions of the MCIs driven by the drifting-ring-type distribution were compared with those of observed ICEs(3He). The comparison shows that toroidal wavenumbers and frequencies of the calculated MCIs agree with those of the observed ICEs(3He).

  6. Electron Cloud Cyclotron Resonances in the Presence of a Short-bunch-length Relativistic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Yu, Jennifer W.

    2008-09-02

    Computer simulations using the 2D code"POSINST" were used to study the formation of the electron cloud in the wiggler section of the positron damping ring of the International Linear Collider. In order to simulate an x-y slice of the wiggler (i.e., a slice perpendicular to the beam velocity), each simulation assumed a constant vertical magnetic field. At values of the magnetic field where the cyclotron frequency was an integral multiple of the bunch frequency, and where the field strength was less than approximately 0.6 T, equilibrium average electron densities were up to three times the density found at other neighboring field values. Effects of this resonance between the bunch and cyclotron frequency are expected to be non-negligible when the beam bunch length is much less than the product of the electron cyclotron period and the beam velocity, for a beam moving at v~;;c. Details of the dynamics of the resonance are described.

  7. Cherenkov-cyclotron instability in a metamaterial loaded waveguide for high power generation

    Science.gov (United States)

    Lu, Xueying; Shapiro, Michael; Temkin, Richard

    2017-10-01

    This work presents the analytical theory for an S-band high power microwave experiment at MIT utilizing a metamaterial (MTM) structure. A 490 kV, 84 A electron beam travels through a rectangular waveguide loaded with two MTM plates in a DC magnetic field B0. The excited waveguide mode is deflecting with a transverse E field on beam axis. Microsecond long megawatt level microwave pulses were generated under a low B0 in the Cherenkov-cyclotron type of interaction. A linear theory has been developed to explain the high power generation due to the Cherenkov-cyclotron instability. The simplified model is a planar waveguide filled with a double negative dispersive medium, and in the mode being studied, the longitudinal E field has an antisymmetric pattern in the direction perpendicular to the MTM plates. We have proved that the Cherenkov-cyclotron instability can happen with a zero initial transverse beam velocity when B0 is below a threshold. Also this instability is a unique feature of the left-handed MTM, since it requires a propagating mode below the cut-off frequency. The minimum beam current to start the instability is calculated, and the scaling law different from that of the traditional backward wave oscillators operated by longitudinal bunching will be discussed. This research was supported by the Air Force Office of Scientific Research within the Multidisciplinary University Research Initiative under Grant No. FA9550-12-1-0489 through the University of New Mexico.

  8. Review on production of 89Zr in a medical cyclotron for PET radiopharmaceuticals.

    Science.gov (United States)

    Kasbollah, Azahari; Eu, Peter; Cowell, Simon; Deb, Pradip

    2013-03-01

    This article is intended to provide an overview of the production and application of (89)Zr for the professional development of nuclear medicine technologists. It outlines the cyclotron targeting, separation and labeling options, and techniques for the preparation of the radionuclide (89)Zr (half-life, 78.4 h [3.3 d]) used in PET. Unlike the commonly used (18)F-FDG, with a 109.7-min half-life, the longer half-life of (89)Zr makes it possible to use high-resolution PET/CT to localize and image tumors with monoclonal antibody radiopharmaceuticals and thus potentially expand the use of PET. This paper briefly reviews the cyclotron technique of (89)Zr production and outlines the range and preparation techniques available for making (89)Y targets as a starting material. It then discusses how cyclotron-produced (89)Zr can be separated, purified, and labeled to monoclonal antibodies for PET/CT of specific tumors. We argue that knowledge and understanding of this long-lived PET radionuclide should be part of the professional development of nuclear medicine technologists because it will lead to better patient outcomes and potentially increase the pool of collaborators in this field of research.

  9. Ion cyclotron and spin-flip emissions from fusion products in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Arunasalam, V.; Greene, G.J.; Young, K.M.

    1993-02-01

    Power emission by fusion products of tokamak plasmas in their ion cyclotron range of frequencies (ICRF) and at their spin-flip resonance frequency is calculated for some specific model fusion product velocity-space distribution functions. The background plasma of say deuterium (D) is assumed to be in equilibrium with a Maxwellian distribution both for the electrons and ions. The fusion product velocity distributions analyzed here are: (1) A monoenergetic velocity space ring distribution. (2) A monoenergetic velocity space spherical shell distribution. (3) An anisotropic Maxwellian distribution with T {perpendicular} {ne} T{parallel}and with appreciable drift velocity along the confining magnetic field. Single ``dressed`` test particle spontaneous emission calculations are presented first and the radiation temperature for ion cyclotron emission (ICE) is analyzed both for black-body emission and nonequilibrium conditions. Thresholds for instability and overstability conditions are then examined and quasilinear and nonlinear theories of the electromagnetic ion cyclotron modes are discussed. Distinctions between ``kinetic or causal instabilities`` and ``hydrodynamic instabilities`` are drawn and some numerical estimates are presented for typical tokamak parameters. Semiquantitative remarks are offered on wave accessibility, mode conversion, and parametric decay instabilities as possible for spatially localized ICE. Calculations are carried out both for k{parallel} = 0 for k{parallel} {ne} 0. The effects of the temperature anisotropy and large drift velocities in the parallel direction are also examined. Finally, proton spin-flip resonance emission and absorption calculations are also presented both for thermal equilibrium conditions and for an ``inverted`` population of states.

  10. Overview of the future upgrade of the INFN-LNS superconducting cyclotron

    Science.gov (United States)

    Calabretta, Luciano; Calanna, Alessandra; Cuttone, Giacomo; D'Agostino, Grazia; Rifuggiato, Danilo; Domenico Russo, Antonio

    2017-06-01

    The LNS Superconducting Cyclotron, named “Ciclotrone Superconduttore” (CS), has been in operation for more than 20 years. A wide range of ion species from hydrogen to lead, with energy in the range 10 to 80 AMeV, have been delivered to users. The maximum beam power is limited to 100 W due to the beam dissipation on the electrostatic deflectors. To fulfil the demand of users aiming at studying rare processes in nuclear physics, an upgrade of the cyclotron is necessarily intended to increase the intensity of ion beams with mass lower than 40 a.m.u. up to a power 10 kW. This will be achieved by means of extraction by stripping. This solution needs to replace the cryostat including the superconducting coils. The present capability of the cyclotron will be maintained, i.e. all the ion species allowed by the operating diagram will be available, being extracted by electrostatic extraction. In addition to the high power beams for nuclear physics, it will be possible to produce medical radioisotopes like 211At using an internal target.

  11. Advances in intense beams, beam delivery, targetry, and radiochemistry at advanced cyclotron systems

    Science.gov (United States)

    Johnson, R. R.; Watt, R.; Kovac, B.; Zyuzin, A.; Van Lier, E.; Erdman, K. L.; Gyles, Wm.; Sabaiduc, V.; McQuarrie, S. A.; Wilson, J.; Backhouse, C.; Gelbart, Wm.; Kuo, T.

    2007-08-01

    The increasing demand for radionuclides for PET and SPECT has resulted in ACSI system improvements starting from the cyclotron and proceeding to the Radiochemistry Modules. With more TR30 cyclotrons installed and operating at full capacity, emphasis has been placed on improving the operational components to reduce both the incidence of failure and subsequent maintenance time. A cyclotron system has been developed that meets the needs of a regional radiopharmacy that supplies both positron and single photon emitters that would not otherwise be available. This new system has been named the TR24. In order to deal with some of the challenges of high currents, a method has been developed for passivating the entrance window foil during high current irradiation of a water target used to produce F-18. A method has been developed for passivating the entrance window foil to reduce unwanted chemical species that interfere with radiopharmaceutical production. Preliminary results for novel radioiodine production technique using the TR19/9 are also discussed.

  12. Analytical study of effects of positron density and temperature anisotropy on electrostatic ion cyclotron instability

    Science.gov (United States)

    Barati Moqadam Niyat, M.; Khorashadizadeh, S. M.; Niknam, A. R.

    2017-03-01

    The effects of the positron concentration and ion temperature anisotropy on the electrostatic ion cyclotron instability are studied analytically, in a magnetized electron-positron-ion plasma with temperature anisotropy, using the linear kinetic theory. Positrons and electrons are supposed to drift either in the same direction or in opposite directions relative to singly ionized stationary ions and parallel to the magnetic field. The dispersion relation of the electrostatic ion cyclotron waves is derived, and then the conditions for exciting the instability of the waves are investigated. Moreover, the condition for the marginally stable state is also studied. It is found that as the positron concentration and perpendicular ion temperature increase, the growth rate of the electrostatic ion cyclotron instability decreases, whereas the critical drift velocity increases. It is also found that for the chosen set of parameters, with electrons and positrons drifting in the same direction, the instability in the plasma is stronger than when the electrons and positrons drift in opposite directions. In addition, a comparison is made to the normal electron-ion plasma.

  13. Cyclotron Lines: From Magnetic Field Strength Estimators to Geometry Tracers in Neutron Stars

    Science.gov (United States)

    Maitra, Chandreyee

    2017-09-01

    With forty years since the discovery of the first cyclotron line in Her X-1, there have been remarkable advancements in the field related to the study of the physics of accreting neutron stars - cyclotron lines have been a major torchbearer in this regard, from being the only direct estimator of the magnetic field strength, a tracer of accretion geometry and an indicator of the emission beam in these systems. The main flurry of activities have centred around studying the harmonic separations, luminosity dependence, pulse phase dependence and more recently, the shapes of the line and the trend for long-term evolution in the line energy. This article visits the important results related to cyclotron lines since its discovery and reviews their significance. An emphasis is laid on pulse phase resolved spectroscopy and the important clues a joint timing and spectral study in this context can provide, to build a complete picture for the physics of accretion and hence X-ray emission in accreting neutron stars.

  14. Optical imaging of irradiated cyclotron target window foils using Cerenkov and radioluminescence imaging

    Science.gov (United States)

    Spinelli, A. E.; Boschi, F.; Calandrino, R.

    2017-05-01

    Radioisotopes production for PET radiopharmaceuticals is performed using cyclotrons resulting in radio activation of different cyclotron components. It is thus necessary to measure the level of radiation exposure and, if possible, to image the areas where most of the radiations are emitted in particular during maintenance or decommissioning procedures. In this work we present a novel optical imaging approach using Cerenkov luminescence imaging (CLI) and radioluminescence imaging (RLI). CLI was performed by placing a glass Cerenkov radiator on a target window (Havar foils) and RLI data were obtained by covering the Havar foils with an intensifying screen. CLI or RLI were acquired using a small animal optical imaging system used in bioluminescence mode without the use of any optical filters. The analysis of the normalized radiance line profiles of both CLI and RLI images showed a similar pattern, however the absolute radiance of the RLI signal is several order of magnitude higher with respect to CLI. We conclude that optical imaging with CLI and RLI can be considered a novel method to detect and image activation areas in irradiated samples from a medical cyclotron.

  15. Calibration and use cases of the electron cyclotron emission diagnostic at Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Hoefel, Udo; Hirsch, Matthias; Ewert, Karsten; Hartfuss, Hans-Juergen; Laqua, Heinrich Peter; Stange, Torsten; Wolf, Robert [Max-Planck-Institut fuer Plasmaphysik, Greifswald (Germany); Collaboration: the W7-X Team

    2016-07-01

    The world's largest stellarator, Wendelstein 7-X (W7-X), is equipped with a 140 GHz electron cyclotron resonance heating (ECRH) system providing up to 5 MW absorbed power in the first operation phase OP1.1. The foreseen X2-heating scenario uses the high absorption of the second harmonic extraordinary electron cyclotron waves, which leads on the other hand to a black body electron cyclotron emission (ECE) being proportional to the local electron temperature. ECE is one of the fundamental operating diagnostics and is planned to yield the electron temperature profile from the very first discharges onwards. Unlike most other ECE diagnostics, the 32 channel ECE radiometer diagnostic (with additional 16 channels with higher radial resolution) at W7-X is absolutely calibrated. It is planned to use this diagnostic for intensive studies on electron heat transport in the upcoming operational phases of W7-X. Simple switch-off experiments for the determination of the energy confinement time should already be possible within the first plasma shots. Due to the high temporal and radial resolution the ECE will be used also to determine the power deposition by modulation of the heating gyrotron. or the localization of a power modulated ECRH to optimize the power deposition. If reasonably equilibrated plasma conditions could be generated in the first operational phase (OP 1.1), first studies on electron thermal diffusivity could also be possible.

  16. Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron.

    Science.gov (United States)

    Jones, Kevin C; Vander Stappen, François; Bawiec, Christopher R; Janssens, Guillaume; Lewin, Peter A; Prieels, Damien; Solberg, Timothy D; Sehgal, Chandra M; Avery, Stephen

    2015-12-01

    To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron. An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone. The acoustic measurements were repeated with increasing proton current and increasing distance between detector and beam. The cyclotron generated proton spills with rise times of 18 μs and a maximum measured instantaneous proton current of 790 nA. Acoustic emissions generated by the proton energy deposition were measured to be on the order of mPa. The origin of the acoustic wave was identified as the proton beam based on the correlation between acoustic emission arrival time and distance between the hydrophone and proton beam. The acoustic frequency spectrum peaked at 10 kHz, and the acoustic pressure amplitude increased monotonically with increasing proton current. The authors report the first observation of acoustic emissions generated by a proton beam from a hospital-based clinical cyclotron. When modulated by an electronic function generator, the cyclotron is capable of creating proton spills with fast rise times (18 μs) and high instantaneous currents (790 nA). Measurements of the proton-generated acoustic emissions in a clinical setting may provide a method for in vivo proton range verification and patient monitoring.

  17. Cyclotron resonant scattering feature simulations. II. Description of the CRSF simulation process

    Science.gov (United States)

    Schwarm, F.-W.; Ballhausen, R.; Falkner, S.; Schönherr, G.; Pottschmidt, K.; Wolff, M. T.; Becker, P. A.; Fürst, F.; Marcu-Cheatham, D. M.; Hemphill, P. B.; Sokolova-Lapa, E.; Dauser, T.; Klochkov, D.; Ferrigno, C.; Wilms, J.

    2017-05-01

    Context. Cyclotron resonant scattering features (CRSFs) are formed by scattering of X-ray photons off quantized plasma electrons in the strong magnetic field (of the order 1012 G) close to the surface of an accreting X-ray pulsar. Due to the complex scattering cross-sections, the line profiles of CRSFs cannot be described by an analytic expression. Numerical methods, such as Monte Carlo (MC) simulations of the scattering processes, are required in order to predict precise line shapes for a given physical setup, which can be compared to observations to gain information about the underlying physics in these systems. Aims: A versatile simulation code is needed for the generation of synthetic cyclotron lines. Sophisticated geometries should be investigatable by making their simulation possible for the first time. Methods: The simulation utilizes the mean free path tables described in the first paper of this series for the fast interpolation of propagation lengths. The code is parallelized to make the very time-consuming simulations possible on convenient time scales. Furthermore, it can generate responses to monoenergetic photon injections, producing Green's functions, which can be used later to generate spectra for arbitrary continua. Results: We develop a new simulation code to generate synthetic cyclotron lines for complex scenarios, allowing for unprecedented physical interpretation of the observed data. An associated XSPEC model implementation is used to fit synthetic line profiles to NuSTAR data of Cep X-4. The code has been developed with the main goal of overcoming previous geometrical constraints in MC simulations of CRSFs. By applying this code also to more simple, classic geometries used in previous works, we furthermore address issues of code verification and cross-comparison of various models. The XSPEC model and the Green's function tables are available online (see link in footnote, page 1).

  18. Effective production of ⁶⁵Zn with a PET cyclotron.

    Science.gov (United States)

    Lucconi, G; Cicoria, G; Pancaldi, D; Malizia, C; Marengo, M

    2012-08-01

    Cyclotrons dedicated to the production of PET radiopharmaceuticals for clinical use can be a resource also for research in other fields of science. In the present study we assessed the feasibility of (65)Zn production via the (65)Cu(p,n)(65)Zn reaction using a 16.5 MeV GE-PETtrace biomedical cyclotron. The radioisotope (65)Zn (t(1/2)=244.26 zd; decay mode: EC 98.3%, β(+) 1.7%) has a wide range of applications, especially in botany and agriculture; its long half life allows storage and delivery to research centers without a cyclotron on site. Natural copper foils (thickness: 100 μm; purity: >99.9%) were irradiated in a solid target station developed in our institution. The EXFOR and IAEA cross sections databases were carefully studied to optimize the irradiation setup in order to maximize the yield of the radionuclide of interest and minimize the production of isotopic impurities. We performed production runs at 20 μA for 30 min. Activity was measured using a calibrated HPGe gamma ray detector and an ionization chamber radionuclide activity meter. These measures showed the presence of two main contaminants: (63)Zn (t(1/2)=38.47 min) and (64)Cu (t(1/2)=12.7h); we produced (65)Zn with a saturation yield of (1.06 ± 0.07) GBq/μA (E(p)=12.65→10.48 MeV). The irradiated target was dissolved in 1 ml of 6N HNO(3) at the temperature of 90°C and then purified through anion exchange chromatography with BIO RAD AG 1×8 resin. The radionuclidic purity of the final solution of (65)Zn in HCl 0.005 N, expressed in activity, resulted superior to (99.921 ± 0.003) %. Copyright © 2012. Published by Elsevier Ltd.

  19. Recent achievements in Tc-99m radiopharmaceutical direct production by medical cyclotrons.

    Science.gov (United States)

    Boschi, Alessandra; Martini, Petra; Pasquali, Micol; Uccelli, Licia

    2017-09-01

    99mTc is the most commonly used radionuclide in the field of diagnostic imaging, a noninvasive method intended to diagnose a disease, assess the disease state and monitor the effects of treatments. Annually, the use of 99mTc, covers about 85% of nuclear medicine applications. This isotope releases gamma rays at about the same wavelength as conventional X-ray diagnostic equipment, and owing to its short half-life (t½ = 6 h) is ideal for diagnostic nuclear imaging. A patient can be injected with a small amount of 99mTc and within 24 h almost 94% of the injected radionuclide would have decayed and left the body, limiting the patient's radiation exposure. 99mTc is usually supplied to hospitals through a 99Mo/99mTc radionuclide generator system where it is produced from the β decay of the parent nuclide 99Mo (t½ = 66 h), which is produced in nuclear reactors via neutron fission. Recently, the interruption of the global supply chain of reactor-produced 99Mo, has forced the scientific community to investigate alternative production routes for 99mTc. One solution was to consider cyclotron-based methods as potential replacement of reactor-based technology and the nuclear reaction 100Mo(p,2n)99mTc emerged as the most worthwhile approach. This review reports some achievements about 99mTc produced by medical cyclotrons. In particular, the available technologies for target design, the most efficient extraction and separation procedure developed for the purification of 99mTc from the irradiated targets, the preparation of high purity 99mTc radiopharmaceuticals and the first clinical studies carried out with cyclotron produced 99mTc are described.

  20. Ion cyclotron and spin-flip emissions from fusion products in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Arunasalam, V.; Greene, G.J.; Young, K.M.

    1993-02-01

    Power emission by fusion products of tokamak plasmas in their ion cyclotron range of frequencies (ICRF) and at their spin-flip resonance frequency is calculated for some specific model fusion product velocity-space distribution functions. The background plasma of say deuterium (D) is assumed to be in equilibrium with a Maxwellian distribution both for the electrons and ions. The fusion product velocity distributions analyzed here are: (1) A monoenergetic velocity space ring distribution. (2) A monoenergetic velocity space spherical shell distribution. (3) An anisotropic Maxwellian distribution with T [perpendicular] [ne] T[parallel]and with appreciable drift velocity along the confining magnetic field. Single dressed'' test particle spontaneous emission calculations are presented first and the radiation temperature for ion cyclotron emission (ICE) is analyzed both for black-body emission and nonequilibrium conditions. Thresholds for instability and overstability conditions are then examined and quasilinear and nonlinear theories of the electromagnetic ion cyclotron modes are discussed. Distinctions between kinetic or causal instabilities'' and hydrodynamic instabilities'' are drawn and some numerical estimates are presented for typical tokamak parameters. Semiquantitative remarks are offered on wave accessibility, mode conversion, and parametric decay instabilities as possible for spatially localized ICE. Calculations are carried out both for k[parallel] = 0 for k[parallel] [ne] 0. The effects of the temperature anisotropy and large drift velocities in the parallel direction are also examined. Finally, proton spin-flip resonance emission and absorption calculations are also presented both for thermal equilibrium conditions and for an inverted'' population of states.

  1. Electron cyclotron resonance near the axis of the gas-dynamic trap

    Science.gov (United States)

    Bagulov, D. S.; Kotelnikov, I. A.

    2012-08-01

    Propagation of an extraordinary electromagnetic wave in the vicinity of electron cyclotron resonance surface in an open linear trap is studied analytically, taking into account inhomogeneity of the magnetic field in paraxial approximation. Ray trajectories are derived from a reduced dispersion equation that makes it possible to avoid the difficulty associated with a transition from large propagation angles to the case of strictly longitudinal propagation. Our approach is based on the theory, originally developed by Zvonkov and Timofeev [Sov. J. Plasma Phys. 14, 743 (1988)], who used the paraxial approximation for the magnetic field strength, but did not consider the slope of the magnetic field lines, which led to considerable error, as has been recently noted by Gospodchikov and Smolyakova [Plasma Phys. Rep. 37, 768-774 (2011)]. We have found ray trajectories in analytic form and demonstrated that the inhomogeneity of both the magnetic field strength and the field direction can qualitatively change the picture of wave propagation and significantly affect the efficiency of electron cyclotron heating of a plasma in a linear magnetic trap. Analysis of the ray trajectories has revealed a criterion for the resonance point on the axis of the trap to be an attractor for the ray trajectories. It is also shown that a family of ray trajectories can still reach the resonance point on the axis if the latter generally repels the ray trajectories. As an example, results of general theory are applied to the electron cyclotron resonance heating experiment which is under preparation on the gas dynamic trap in the Budker Institute of Nuclear Physics [Shalashov et al., Phys. Plasmas 19, 052503 (2012)].

  2. Electron acceleration at Jupiter: input from cyclotron-resonant interaction with whistler-mode chorus waves

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    2013-10-01

    Full Text Available Jupiter has the most intense radiation belts of all the outer planets. It is not yet known how electrons can be accelerated to energies of 10 MeV or more. It has been suggested that cyclotron-resonant wave-particle interactions by chorus waves could accelerate electrons to a few MeV near the orbit of Io. Here we use the chorus wave intensities observed by the Galileo spacecraft to calculate the changes in electron flux as a result of pitch angle and energy diffusion. We show that, when the bandwidth of the waves and its variation with L are taken into account, pitch angle and energy diffusion due to chorus waves is a factor of 8 larger at L-shells greater than 10 than previously shown. We have used the latitudinal wave intensity profile from Galileo data to model the time evolution of the electron flux using the British Antarctic Survey Radiation Belt (BAS model. This profile confines intense chorus waves near the magnetic equator with a peak intensity at ∼5° latitude. Electron fluxes in the BAS model increase by an order of magnitude for energies around 3 MeV. Extending our results to L = 14 shows that cyclotron-resonant interactions with chorus waves are equally important for electron acceleration beyond L = 10. These results suggest that there is significant electron acceleration by cyclotron-resonant interactions at Jupiter contributing to the creation of Jupiter's radiation belts and also increasing the range of L-shells over which this mechanism should be considered.

  3. Direct production of 99mTc using a small medical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Lapi, Suzanne [Washington Univ., St. Louis, MO (United States)

    2017-10-03

    This project describes an investigation towards the production of 99mTc with a small medical cyclotron. This endeavor addresses the current urgent problem of availability of 99mTc due to the ongoing production reactor failures and the upcoming Canadian reactor shut down. Currently, 99mTc is produced via nuclear fission using highly enriched uranium which is a concern due to nuclear proliferation risks. In addition to this, the United States is dependent solely on currently unreliable foreign sources of this important medical isotope. Clearly, a need exists to probe alternative production routes of 99mTc. In the first year, this project measured cross-sections and production yields of potential pathways to 99mTc and associated radionuclidic impurities produced via these pathways using a small 15 MeV medical cyclotron. During the second and third years target systems for the production of 99mTc via the most promising reaction routes were developed and separation techniques for the isolation of 99mTc from the irradiated target material will be investigated. Systems for the recycling of the enriched target isotopes as well as automated target processing systems were examined in years four and five. This project has the potential to alleviate some of the current crisis in the medical community by developing a technique to produce 99mTc on location at a university hospital. This technology will be applicable at many other sites in the United States as many other similar, low energy (<20 MeV) cyclotrons (currently used for a few hours per day for the production of [18F]fluorodeoxyglucose) are available for production of 99mTc though this method, thus leading to job creation and preservation.

  4. Effective dose to immuno-PET patients due to metastable impurities in cyclotron produced zirconium-89

    Science.gov (United States)

    Alfuraih, Abdulrahman; Alzimami, Khalid; Ma, Andy K.; Alghamdi, Ali; Al Jammaz, Ibrahim

    2014-11-01

    Immuno-PET is a nuclear medicine technique that combines positron emission tommography (PET) with radio-labeled monoclonal antibodies (mAbs) for tumor characterization and therapy. Zirconium-89 (89Zr) is an emerging radionuclide for immuno-PET imaging. Its long half-life (78.4 h) gives ample time for the production, the administering and the patient uptake of the tagged radiopharmaceutical. Furthermore, the nuclides will remain in the tumor cells after the mAbs are catabolized so that time series studies are possible without incurring further administration of radiopharmarceuticals. 89Zr can be produced in medical cyclotrons by bombarding an yttrium-89 (89Y) target with a proton beam through the 89Y(p,n)89Zr reaction. In this study, we estimated the effective dose to the head and neck cancer patients undergoing 89Zr-based immune-PET procedures. The production of 89Zr and the impurities from proton irradiation of the 89Y target in a cyclotron was calculated with the Monte Carlo code MCNPX and the nuclear reaction code TALYS. The cumulated activities of the Zr isotopes were derived from real patient data in literature and the effective doses were estimated using the MIRD specific absorbed fraction formalism. The estimated effective dose from 89Zr is 0.5±0.2 mSv/MBq. The highest organ dose is 1.8±0.2 mSv/MBq in the liver. These values are in agreement with those reported in literature. The effective dose from 89mZr is about 0.2-0.3% of the 89Zr dose in the worst case. Since the ratio of 89mZr to 89Zr depends on the cooling time as well as the irradiation details, contaminant dose estimation is an important aspect in optimizing the cyclotron irradiation geometry, energy and time.

  5. Modelling third harmonic ion cyclotron acceleration of deuterium beams for JET fusion product studies experiments

    DEFF Research Database (Denmark)

    Schneider, M.; Johnson, T.; Dumont, R.

    2016-01-01

    Recent JET experiments have been dedicated to the studies of fusion reactions between deuterium (D) and Helium-3 (3He) ions using neutral beam injection (NBI) in synergy with third harmonic ion cyclotron radio-frequency heating (ICRH) of the beam. This scenario generates a fast ion deuterium tail...... ion diagnostics, showing an overall good agreement. Finally, a sawtooth activity for these experiments has been observed and interpreted using SPOT/RFOF simulations in the framework of Porcelli’s theoretical model, where NBI+ICRH accelerated ions are found to have a strong stabilizing effect, leading...

  6. A real-time beam-profile monitor for a PET cyclotron

    Science.gov (United States)

    Hoehr, C.; Uittenbosch, T.; Verzilov, V.; English, W.; Buckley, K.; Gray, D.; Kellog, S.; Cameron, D.; Schaffer, P.

    2012-12-01

    Beam profiles in medical cyclotrons are traditionally measured using techniques that do not provide any information about short-term fluctuations of the beam shape or beam intensity. To overcome this, we have developed a real-time harp beam profile monitor which can withstand beam power in excess of 300 W. The monitor and electronics were constructed and applied toward a 13 MeV proton beam with current of up to 25 μA. Herein are reported preliminary beam-profile measurement results.

  7. Status of the Bio-Nano electron cyclotron resonance ion source at Toyo University

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T., E-mail: uchida-t@toyo.jp [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Minezaki, H.; Ishihara, S. [Graduate School of Engineering, Toyo University, Kawagoe 350-8585 (Japan); Muramatsu, M.; Kitagawa, A.; Drentje, A. G. [National Institute of Radiological Sciences (NIRS), Chiba 263-8555 (Japan); Rácz, R.; Biri, S. [Institute for Nuclear Research (ATOMKI), H-4026 Debrecen (Hungary); Asaji, T. [Oshima National College of Maritime Technology, Yamaguchi 742-2193 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, Suita 565-0871 (Japan); Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Graduate School of Engineering, Toyo University, Kawagoe 350-8585 (Japan)

    2014-02-15

    In the paper, the material science experiments, carried out recently using the Bio-Nano electron cyclotron resonance ion source (ECRIS) at Toyo University, are reported. We have investigated several methods to synthesize endohedral C{sub 60} using ion-ion and ion-molecule collision reaction in the ECRIS. Because of the simplicity of the configuration, we can install a large choice of additional equipment in the ECRIS. The Bio-Nano ECRIS is suitable not only to test the materials production but also to test technical developments to improve or understand the performance of an ECRIS.

  8. Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Asaji, T., E-mail: asaji@oshima-k.ac.jp; Ohba, T. [Oshima National College of Maritime Technology, 1091-1 Komatsu, Suo-oshima, Oshima, Yamaguchi 742-2193 (Japan); Uchida, T.; Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Minezaki, H.; Ishihara, S. [Graduate School of Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Racz, R.; Biri, S. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem Tér 18/c (Hungary); Muramatsu, M.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2014-02-15

    A synthesis technology of endohedral fullerenes such as Fe@C{sub 60} has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C{sub 60} was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.

  9. Wave intensifications near the electron cyclotron frequency within the polar cusp

    Science.gov (United States)

    Farrell, W. M.; Gurnett, D. A.; Menietti, J. D.; Wong, H. K.; Lin, C. S.

    1990-01-01

    As DE 1 flew through the polar cusp, enhanced narrowband electrostatic waves were sometimes observed just above the electron cyclotron frequency. Here, wave and particle measurements from three representative cusp transits are presented in order to characterize these signals and understand the conditions that favor their generation. It was found that the form of the local cusp electron velocity distribution had a direct influence on the wave spectral character. A preliminary study indicates that electron beams in the cusp can generate the enhanced signals, although generation by an anisotropic warm component cannot be ruled out.

  10. Development of a prototype T-shaped fast switching device for electron cyclotron current drive systems

    Science.gov (United States)

    Sekiguchi, Kenji; Nagashima, Koji; Honzu, Toshihiko; Saigusa, Mikio; Oda, Yasuhisa; Takahashi, Koji; Sakamoto, Keishi

    2016-09-01

    A T-shaped high-power switching device composed of circular corrugated waveguides with three ports and double dielectric disks made of sapphire was proposed as a fast switching device based on a new principle in electron cyclotron current drive systems. This switching device has the advantages of operating at a fixed frequency and being compact. The design of the prototype switch was obtained by numerical simulations using a finite-difference time-domain (FDTD) method. The size of these components was optimized for the frequency band of 170 GHz. Low-power tests were carried out in a cross-shaped model.

  11. Interaction of the electron density fluctuations with electron cyclotron waves from the equatorial launcher in ITER

    Science.gov (United States)

    Snicker, A.; Poli, E.; Maj, O.; Guidi, L.; Köhn, A.; Weber, H.; Conway, G. D.; Henderson, M.; Saibene, G.

    2018-01-01

    We present a numerical investigation of electron cyclotron beams interacting with electron density fluctuations in the ITER 15 MA H-mode scenario. In particular, here we study how the beam from the equatorial launcher, which shall be utilized to influence the sawtooth instability, is affected by the fluctuations. Moreover, we present the theory and first estimates of the power that is scattered from the injected O-mode to a secondary X-mode in the presence of the fluctuations. It is shown that for ITER parameters the scattered power stays within acceptable limits and broadening of the equatorial beams is less than those from the upper launcher.

  12. An analytical approach of thermodynamic behavior in a gas target system on a medical cyclotron.

    Science.gov (United States)

    Jahangiri, Pouyan; Zacchia, Nicholas A; Buckley, Ken; Bénard, François; Schaffer, Paul; Martinez, D Mark; Hoehr, Cornelia

    2016-01-01

    An analytical model has been developed to study the thermo-mechanical behavior of gas targets used to produce medical isotopes, assuming that the system reaches steady-state. It is based on an integral analysis of the mass and energy balance of the gas-target system, the ideal gas law, and the deformation of the foil. The heat transfer coefficients for different target bodies and gases have been calculated. Excellent agreement is observed between experiments performed at TRIUMF's 13 MeV cyclotron and the model. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Nonlocal weakly relativistic permittivity tensor of magnetized plasma near electron cyclotron resonances

    Science.gov (United States)

    Sakharov, A. S.

    2017-11-01

    Compact expressions are derived for the nonlocal permittivity tensor of weakly relativistic plasma in a 2D nonuniform magnetic field near the resonances at the second harmonic of the electron cyclotron frequency for an extraordinary wave and at the first harmonic for an ordinary wave. It is shown that the wave equation with allowance for the obtained thermal correction to the permittivity tensor in the form of a differential operator in transverse (with respect to the external magnetic field) coordinates possesses an integral in the form of the energy conservation law.

  14. The Spontaneous Loss of Coherence Catastrophe in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    Science.gov (United States)

    Aizikov, Konstantin; Mathur, Raman; O’Connor, Peter B.

    2009-01-01

    The spontaneous loss of coherence catastrophe (SLCC) is a frequently observed, yet poorly studied, space-charge related effect in Fourier-transform ion cyclotron resonance mass spectrometry (FTICR-MS). This manuscript presents an application of the filter diagonalization method (FDM) in the analysis of this phenomenon. The temporal frequency behavior reproduced by frequency shift analysis using the FDM shows the complex nature of the SLCC, which can be explained by a combination of factors occurring concurrently, governed by electrostatics and ion packet trajectories inside the ICR cell. PMID:19013078

  15. Spectra of KeV Protons Related to Ion-Cyclotron Wave Packets

    Science.gov (United States)

    Khazanov, G. V.; Sibeck, D. G.; Tel'Nikhin, A. A.; Kronberg, T. K.

    2017-01-01

    We use the Fokker-Planck-Kolmogorov equation to study the statistical aspects of stochastic dynamics of the radiation belt (RB) protons driven by nonlinear electromagnetic ion-cyclotron (EMIC) wave packets. We obtain the spectra of keV protons scattered by these waves that showsteeping near the gyroresonance, the signature of resonant wave-particle interaction that cannot be described by a simple power law. The most likely mechanism for proton precipitation events in RBs is shown to be nonlinear wave-particle interaction, namely, the scattering of RB protons into the loss cone by EMIC waves.

  16. Design of the central region in the Gustaf Werner cyclotron at the Uppsala university

    CERN Document Server

    Toprek, D; Lundstrom, B; Wessman, D

    2002-01-01

    This paper describes the design of the central region in the Gustaf Werner cyclotron for h=1, 2 and 3 modes of acceleration. The electric field distribution in the inflector and in the four acceleration gaps has been numerically calculated from an electric potential map produced by the program RELAX3D. The geometry of the central region has been tested with the computations of orbits carried out by means of the computer code CYCLONE. The optical properties of the spiral inflector and the central region were studied by using the programs CASINO and CYCLONE, respectively.

  17. Multiply charged ion dissociation in Fourier transform ion cyclotron resonance mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Qinyuan; Bakhtair, R.; Sherman, M.G.; Hofstadler, S.A.; Smith, R.D. [Pacific Northwest Laboratory, Richland, WA (United States)

    1994-12-31

    Bimolecular ions of up to MDa size with thousands of charges have recently been trapped and studied in this laboratory using electrospray ionization (ESI) and Fourier transform ion cyclotron resonance mass spectrometer (FTICRMS). For structural analysis, multiply charged ions generated by ESI can be dissociated at the interface, by collision induced dissociation (CID) or Surface induced dissociation (SID). However, charge exchange with the surface and charge partition among the fragments significantly complicate the SID and CID spectra of multiply charged large ions. High resolution FTICR is an ideal solution to this problem.

  18. Computer modeling of beam space charge effects in cyclotron injector into JINR phasotron

    CERN Document Server

    Kalinichenko, V V

    2002-01-01

    Charge particle beam dynamics including space charge by direct Coulomb particle-to-particle method was simulated. For this purpose in MATLAB a new code KASKADS was developed. Numerical simulations of the particle motion confirm that it is possible to achieve separated orbits in a 5 MeV, 30 mA separated sector cyclotron (accelerating voltage varies depending on radius from 150 kV in the centre to 240 kV in the extraction region). The aperture of the accelerator must be greater than 3 cm.

  19. New approach in design of efficient low level RF circuit for 10 MeV cyclotron

    Directory of Open Access Journals (Sweden)

    M S Sharifi Asadi Malafeh

    2015-09-01

    Full Text Available The electric field in cavity accelerates charged particles and magnetic field of magnets changes the direction of these particles in cyclotrons. In order to establish the electric field inside the cavity, a noiseless radio frequency (RF signal should be generated, amplified and sent to cavity. The resonant frequency of the cavity could be changed by temperature variation. Variation of resonant frequency will cause reflected power from the cavity. in this work the low level RF circuits with task of signal generation, phase and frequency Adjustment, cavity resonant frequency Adjustment, protection of the RF set from the reflected power and stability of RF system was designed

  20. Theory of electromagnetic cyclotron wave growth in a time-varying magnetoplasma

    Science.gov (United States)

    Gail, William B.

    1990-01-01

    The effect of a time-dependent perturbation in the magnetoplasma on the wave and particle populations is investigated using the Kennel-Petchek (1966) approach. Perturbations in the cold plasma density, energetic particle distribution, and resonance condition are calculated on the basis of the ideal MHD assumption given an arbitrary compressional magnetic field perturbation. An equation is derived describing the time-dependent growth rate for parallel propagating electromagnetic cyclotron waves in a time-varying magnetoplasma with perturbations superimposed on an equilibrium configuration.

  1. Calculating method for confinement time and charge distribution of ions in electron cyclotron resonance sources

    Energy Technology Data Exchange (ETDEWEB)

    Dougar-Jabon, V.D. [Escuela de Fisica, Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia); Umnov, A.M. [Russian Friendship University, 117198 Moscow (Russia); Kutner, V.B. [Joint Institute for Nuclear Research, Dubna (Russia)

    1996-03-01

    It is common knowledge that the electrostatic pit in a core plasma of electron cyclotron resonance sources exerts strict control over generation of ions in high charge states. This work is aimed at finding a dependence of the lifetime of ions on their charge states in the core region and to elaborate a numerical model of ion charge dispersion not only for the core plasmas but for extracted beams as well. The calculated data are in good agreement with the experimental results on charge distributions and magnitudes for currents of beams extracted from the 14 GHz DECRIS source. {copyright} {ital 1996 American Institute of Physics.}

  2. Coupled operation of the Oak Ridge isochronous cyclotron and the 25 MV tandem

    Energy Technology Data Exchange (ETDEWEB)

    Lord, R.S.; Ball, J.B.; Beckers, R.M.; Cleary, T.P.; Hudson, E.D.; Ludemann, C.A.; Martin, J.A.; Milner, W.T.; Mosko, S.W.; Ziegler, N.F.

    1981-01-01

    Coupled operation of the 25 MV tandem and the Oak Ridge Isochronous Cyclotron (ORIC) was achieved on January 27, 1981. A beam of 38 MeV /sup 16/O/sup 2 +/ was injected into ORIC, stripped to 8/sup +/ and accelerated to 324 MeV. Shortly afterwards, the energy was increased to the maximum design value of 25 MeV/amu (400 MeV). A spectrum taken of the scattering of this beam from a thin /sup 208/Pb target in the broad range spectrograh exhibited a resolution of 115 keV (FWHM). Performance of the system was in close agreement with that predicted from calculations.

  3. Preliminary results of ion trajectory tracking in the acceleration region of the VINCY cyclotron

    Directory of Open Access Journals (Sweden)

    Ilić Anđelija Ž.

    2006-01-01

    Full Text Available In an accelerating region of a cyclotron, an ion makes a large number of turns; thus, its n the Runge-Kutta method of the fourth order with the adaptive time step has been developed. The accuracy requirement is simultaneously set on position and momentum calculation. Magnetic fields used as inputs, have been evaluated in terms of the radial fluctuations of the orbital frequency, i.e. their isochronisms. Ion trajectory tracking has been performed for the following four test beams: H-, H+3, 4He+, He+, and 40Ar6+.

  4. Photovoltaic infrared photoresponse of the high-mobility graphene quantum Hall system due to cyclotron resonance

    Science.gov (United States)

    Masubuchi, Satoru; Onuki, Masahiro; Arai, Miho; Yamaguchi, Takehiro; Watanabe, Kenji; Taniguchi, Takashi; Machida, Tomoki

    2013-09-01

    We report on the infrared photoresponse of high-mobility graphene in high magnetic fields. Two types of photoresponse signals were observed that were due to photovoltaic and bolometric effects. The photovoltaic signal was observed in the quantum Hall regime, whereas the bolometric signal was dominant in the quantum Hall transition regime. The photovoltaic effect, which was induced by cyclotron resonance, was observable up to 180 K. The polarity of the photovoltaic photoresponse was shown to be systematically reversed on reversal of the applied magnetic field direction and measurement geometry, suggesting that the photovoltage signals were generated along the quantum Hall edge channel.

  5. Distorted cyclotron line profile in Cep X-4 as observed by NuSTAR

    DEFF Research Database (Denmark)

    Fürst, F.; Pottschmidt, K.; Miyasaka, H.

    2015-01-01

    deviations at the red side of the line. We characterize this asymmetry with a second absorption feature around 19 keV. The line energy of the CRSF, which is not influenced by the addition of this feature, shows a small but significant positive luminosity dependence. With luminosities between (1-6)e36 erg...... a powerlaw with a Fermi-Dirac cutoff at high energies. Cep X-4 has a very strong cyclotron resonant scattering feature (CRSF) around 30 keV. A simple absorption-like line with a Gaussian optical depth or a pseudo-Lorentzian profile both fail to describe the shape of the CRSF accurately, leaving significant...

  6. Filling and Recycling Apparatus of a Cyclotron Target with Enriched Krypton for Production of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    M. Vognar

    2001-01-01

    Full Text Available An apparatus for multiple filling of a cyclotron target with enriched Kr gas is described. The system is based on recycling pressurized gas by cryogenic pumping between the target tube and storage containers. The design and construction makes use of previous experience in the construction and operation of two analogue apparatuses for Xe124 high pressure gas targets, but major modifications have been incorporated, evoked by the different physical properties of Kr, by the character of the nuclear reaction, and by the demand for automation from the side of the end user.

  7. Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics.

    Science.gov (United States)

    Lu, W; Xie, D Z; Zhang, X Z; Xiong, B; Ruan, L; Sha, S; Zhang, W H; Cao, Y; Lin, S H; Guo, J W; Fang, X; Guo, X H; Li, X X; Ma, H Y; Yang, Y; Wu, Q; Zhao, H Y; Ma, B H; Wang, H; Zhu, Y H; Feng, Y C; Li, J Y; Li, J Q; Sun, L T; Zhao, H W

    2012-02-01

    A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

  8. Effect of pulse-modulated microwaves on fullerene ion production with electron cyclotron resonance ion source.

    Science.gov (United States)

    Asaji, T; Uchida, T; Minezaki, H; Oshima, K; Racz, R; Muramatsu, M; Biri, S; Kitagawa, A; Kato, Y; Yoshida, Y

    2012-02-01

    Fullerene plasmas generated by pulse-modulated microwaves have been investigated under typical conditions at the Bio-Nano electron cyclotron resonance ion source. The effect of the pulse modulation is distinct from that of simply structured gases, and then the density of the fullerene plasmas increased as decreasing the duty ratio. The density for a pulse width of 10 μs at the period of 100 μs is 1.34 times higher than that for CW mode. We have studied the responses of fullerene and argon plasmas to pulsed microwaves. After the turnoff of microwave power, fullerene plasmas lasted ∼30 times longer than argon plasmas.

  9. Preparation of Bismuth Titanate Films by Electron Cyclotron Resonance Plasma Sputtering-Chemical Vapor Deposition

    OpenAIRE

    Masumoto, H.; Hirai, T.

    1995-01-01

    Bismuth titanate (Bi4Ti3O12 : BIT) thin films were prepared on the Pt courted MgO(100) substrate by electron cyclotron resonance plasma sputtering-chemical vapor deposition (ECR plasma sputtering-CVD). Bi2O3 was used as a sputtering target and tetra-isopropoxy-titanium [Ti(i-C3H7O)4] as a CVD source. The composition of films was controlled by changing RF power (PRF) of Bi2O3 target and Ti source temperature (TTi). The stoichiometric BIT film was prepared under the condition of PRF=500W, TTi=6...

  10. Phase-resolved optical emission spectroscopy for an electron cyclotron resonance etcher

    Energy Technology Data Exchange (ETDEWEB)

    Milosavljevic, Vladimir [BioPlasma Research Group, Dublin Institute of Technology, Sackville Place, Dublin 1 (Ireland); Biosystems Engineering, University College Dublin, Dublin 4, Ireland and Faculty of Physics, University of Belgrade, Belgrade (Serbia); MacGearailt, Niall; Daniels, Stephen; Turner, Miles M. [NCPST, Dublin City University, Dublin (Ireland); Cullen, P. J. [BioPlasma Research Group, Dublin Institute of Technology, Sackville Place, Dublin 1 (Ireland)

    2013-04-28

    Phase-resolved optical emission spectroscopy (PROES) is used for the measurement of plasma products in a typical industrial electron cyclotron resonance (ECR) plasma etcher. In this paper, the PROES of oxygen and argon atoms spectral lines are investigated over a wide range of process parameters. The PROES shows a discrimination between the plasma species from gas phase and those which come from the solid phase due to surface etching. The relationship between the micro-wave and radio-frequency generators for plasma creation in the ECR can be better understood by the use of PROES.

  11. Remote-Steering Antennas for 140 GHz Electron Cyclotron Heating of the Stellarator W7-X

    Directory of Open Access Journals (Sweden)

    Lechte C.

    2017-01-01

    Full Text Available For electron cyclotron resonance heating of the stellarator W7-X at IPP Greifswald, a 140 GHz/10 MW cw millimeter wave system has been built. Two out of 12 launchers will employ a remote-steering design. This paper describes the overall design of the two launchers, and design issues like input coupling structures, manufacturing of corrugated waveguides, optimization of the steering range, integration of vacuum windows, mitrebends and vacuum valves into the launchers, as well as low power tests of the finished waveguides.

  12. Improving cancer treatment with cyclotron produced radionuclides. Progress report, February 1987--September 1989

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.

    1989-12-31

    This report is divided into six sections, each section dealing with a separate aspect of the program. The six sections are entitled (1) In Vivo Measurement of Amino Acid Transport and Protein Synthesis, (2) Angiogenesis in Human Gliomas: Correlations with Blood Flow and Transport of C-11 AIB, (3) Use of F-18 Fluoropyrimidines for Design and Evaluation of Regional and Systemic Chemotherapeutic Strategies in Human Adenocarcinomas of the Gastrointestinal Tract, (4) Enzymatic Synthesis of Metabolites Labeled with N-13 or C-11, (5) Synthesis of Amino Acids Labeled with C-11, and (6) Instrumentation: Cyclotron and Imaging Systems.

  13. The third generation superconducting 28 GHz electron cyclotron resonance ion source VENUS (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Lyneis, C.; Leitner, D.; Leitner, M.; Taylor, C.; Abbott, S. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California 94720 (United States)

    2010-02-15

    VENUS is a third generation electron cyclotron resonance (ECR) ion source, which incorporates a high field superconducting NbTi magnet structure, a 28 GHz gryotron microwave source and a state of the art closed cycle cryosystem. During the decade from initial concept to regular operation, it has demonstrated both the feasibility and the performance levels of this new generation of ECR ion sources and required innovation on magnet construction, plasma chamber design, and beam transport. In this paper, the development, performance, and major innovations are described as well as a look to the potential to construct a fourth generation ECR ion source.

  14. Remote-Steering Antennas for 140 GHz Electron Cyclotron Heating of the Stellarator W7-X

    Science.gov (United States)

    Lechte, C.; Kasparek, W.; Plaum, B.; Zeitler, A.; Erckmann, V.; Laqua, H.; Schneider, N.; Weissgerber, M.; Bechtold, A.; Busch, M.; Szepaniak, B.

    2017-07-01

    For electron cyclotron resonance heating of the stellarator W7-X at IPP Greifswald, a 140 GHz/10 MW cw millimeter wave system has been built. Two out of 12 launchers will employ a remote-steering design. This paper describes the overall design of the two launchers, and design issues like input coupling structures, manufacturing of corrugated waveguides, optimization of the steering range, integration of vacuum windows, mitrebends and vacuum valves into the launchers, as well as low power tests of the finished waveguides.

  15. The accuracy of heavy-ion mass measurements using time of flight-ion cyclotron resonance in a Penning trap

    Science.gov (United States)

    Bollen, G.; Moore, R. B.; Savard, G.; Stolzenberg, H.

    1990-11-01

    Ion motion in a Penning trap and the electrical signals it can produce have been analyzed for the purpose of identifying the important causes of uncertainty in high-accuracy mass measurements of heavy ions. The role of the azimuthal quadrupole electric field in signal pickup, and its effects on ion motion at the sum frequency of the cyclotron and magnetron motions, have been identified. A useful scheme for calculating the signal strength and strength of the interaction between an applied field and the ion motion has been developed. The important sources of uncertainty in using the sum frequency of the cyclotron and magnetron motions for determining the ion mass are discussed. Particular application is made to the case of cyclotron resonance detection by observation of the time of flight of ejected ions.

  16. Ion cyclotron waves in the Earth’s magnetotail during CASSINI’s Earth swing-by

    Directory of Open Access Journals (Sweden)

    A. T. Bogdanov

    2003-10-01

    Full Text Available The properties of low frequency magnetotail waves observed during CASSINI’s Earth swing-by are examined. A maximum in the distribution of the waves about half the proton cyclotron frequency and a peak at linear polarisation are found and their implications are analysed in detail. Data on the fluid plasma velocity for the observation interval are not available and thus no unique conclusions about Doppler shift influence on the properties of the waves can be made. This determines the need to analyse different hypotheses in order to understand the origin of the waves. The plausibility of competing interpretations, such as off-resonance proton cyclotron waves and bi-ion cyclotron waves at the gyrofrequency of a heavy ion component of the magneto-tail plasma in the form of He ++ ions of solar wind origin is questioned.Key words. Space plasma physics (waves and instabilities – Magnetospheric physics (plasma waves and instabilities; magnetotail

  17. Collision cross section measurements for biomolecules within a high-resolution Fourier transform ion cyclotron resonance cell.

    Science.gov (United States)

    Mao, Lu; Chen, Yu; Xin, Yi; Chen, Yu; Zheng, Li; Kaiser, Nathan K; Marshall, Alan G; Xu, Wei

    2015-04-21

    To understand the role and function of a biomolecule in a biosystem, it is important to know both its composition and structure. Here, a mass spectrometric based approach has been proposed and applied to demonstrate that collision cross sections and high-resolution mass spectra of biomolecule ions may be obtained simultaneously by Fourier transform ion cyclotron resonance mass spectrometry. With this method, the unfolding phenomena for ubiquitin ions that possess different number of charges have been investigated, and results agree well with ion mobility measurements. In the present approach, we extend ion collision cross-section measurements to lower pressures than in prior ion cyclotron resonance (ICR)-based experiments, thereby maintaining the potentially high resolution of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS), and enabling collision cross section (CCS) measurements for high-mass biomolecules.

  18. Numerical Simulation Of The Beam Transmission Efficiency For Design Of Vacuum System Of The Dc-72 Cyclotron

    CERN Document Server

    Tikhomirov, A V; Gulbekyan, G G; Oganesyan, R T

    2004-01-01

    The results of a numerical modelling of the transmission efficiency of ion beams in conditions of ion recharge on the residual gas in the channel of the axial injection, in the cyclotron vacuum chamber, as well as in transport lines of accelerated beams are presented. The computer simulation programs GENAP and VACLOS have been developed and tested on the basis of experiments on four cyclotrons of heavy ions of the Flerov Laboratory of Nuclear Reactions. They estimate beam losses on the basis of calculations of pressure distributions in vacuum chambers of any arbitrary geometry and cross sections of a recharge of ions in exchange reactions by electrons with molecules of residual gas in a wide range of energies and masses of ions. The outcomes of simulation have provided determination of main parameters and technical requirements for the vacuum system of the DC-72 cyclotron.

  19. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Science.gov (United States)

    Zhang, Xu; Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming; Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN-LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  20. Theoretical and experimental study of cyclotronic waves in a fusion plasma; Etude theorique et experimentale des ondes cyclotroniques electroniques dans un plasma de fusion

    Energy Technology Data Exchange (ETDEWEB)

    Vezard, D.

    1994-12-20

    This thesis presents a study concerning cyclotronic waves in a plasma. It starts with an illustration of the elementary interaction between electromagnetic waves and matter.It shows that electrons from tokamak absorbs waves at cyclotronic frequency. Cyclotronic waves are studied by solving the dispersion relation in plasma; it concerns polarisation, absorption, dispersion, extinction. Then, classical theories are reminded in order to speak about decoupled electrons and their interactions. Absorption and emission properties of cyclotronic waves by electrons from a queue are described. After that, cyclotronic waves propagation is studied taking into account resonance. The last part of this thesis is dedicated to the electronic distribution function that is made by a wave spectra at a inferior hybrid frequency. (TEC). 129 refs., 75 figs.

  1. Phase-space resolved measurement of 2nd harmonic ion cyclotron heating using FIDA tomography at the ASDEX Upgrade tokamak

    DEFF Research Database (Denmark)

    Weiland, M.; Bilato, R.; Geiger, B.

    2017-01-01

    Recent upgrades to the FIDA (fast-ion D-alpha) diagnostic at ASDEX Upgrade allow to reconstruct the fast-ion phase space at several radial positions with decent energy and pitch resolution. These new diagnostic capabilities are applied to study the physics of 2nd harmonic ion cyclotron heating......, which is a foreseen heating scenario for ITER. In particular, the acceleration of deuterium beam ions above the injection energy by absorption of ion cyclotron waves at the 2nd harmonic is investigated and compared to theoretical predictions by the TORIC-SSFPQL and TORIC-NUBEAM code packages...

  2. Diagnostic assessment to estimate and minimize neutron dose rates received by occupationally exposed individuals at cyclotron facilities.

    Science.gov (United States)

    Reina, L C; Silva, A X; Suita, J C; Souza, M I S; Facure, A; Silva, J C P; Furlanetto, J A D; Rebello, W

    2010-03-01

    Since 2003, radiopharmaceuticals for medical diagnostic purposes have been produced at the Instituto de Engenharia Nuclear, in Brazil, using two cyclotron accelerators - CV-28 and RDS111. As a result of the ever increasing production, a diagnostic assessment to reduce neutron dose rates received by occupationally exposed individuals during irradiation processes has been developed. The purpose of this work is to present this assessment, which is currently being applied to both the Fluorine and Iodine targets of CV-28 and RDS111 cyclotron accelerators. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Experimental observations of mode-converted ion cyclotron waves in a tokamak plasma by phase contrast imaging.

    Science.gov (United States)

    Nelson-Melby, E; Porkolab, M; Bonoli, P T; Lin, Y; Mazurenko, A; Wukitch, S J

    2003-04-18

    The process of mode conversion, whereby an externally launched electromagnetic wave converts into a shorter wavelength mode(s) in a thermal plasma near a resonance in the index of refraction, is particularly important in a multi-ion species plasma near the ion cyclotron frequency. Using phase contrast imaging techniques (PCI), mode-converted electromagnetic ion cyclotron waves have been detected for the first time in the Alcator C-Mod tokamak near the H-3He ion-ion hybrid resonance region during high power rf heating experiments. The results agree with theoretical predictions.

  4. Study of ion beam transport from the SECRAL electron cyclotron resonance ion source at the Institute of Modern Physics.

    Science.gov (United States)

    Cao, Y; Lu, W; Zhang, W H; Sha, S; Yang, Y; Ma, B H; Wang, H; Zhu, Y H; Guo, J W; Fang, X; Lin, S H; Li, X X; Feng, Y C; Li, J Y; Zhao, H Y; Ma, H Y; Zhang, X Z; Guo, X H; Wu, Q; Sun, L T; Zhao, H W; Xie, D Z

    2012-02-01

    Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

  5. An intrinsically safe facility for forefront research and training on nuclear technologies — An example of accelerator: the SPES cyclotron

    Science.gov (United States)

    Maggiore, M.; Lombardi, A.; Piazza, L. A. C.; Prete, G.

    2014-04-01

    The SPES project, under construction at INFN, Laboratori Nazionali di Legnaro, is a research facility for nuclear and applied physics, based on a high-current H- cyclotron with two exits. One exit will be devoted to supply an ISOL facility for the production of radioactive beams, the second one can be used as driver for the ADS system. The main characteristics of the cyclotron are described together with the main building designed to operate high-current proton beams according to radioprotection rules.

  6. Progress in research, April 1, 1992--March 31, 1993, Texas A and M University Cyclotron Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-07-01

    This Institute annual report for the period 1 April 1992--31 March 1993 covers a period which has seen the initial runs of three new spectrometers which constitute a major portion of the new detection capabilities developed for this facility. These devices are the Proton Spectrometer (PSP), the Mass Achromat Recoil Mass Spectrometer (MARS), and the Multipole dipole Multipole (MDM) Particle Spectrometer. These devices are now available to pursue the studies of Gamow Teller states, reactions of astrophysical interest, and giant resonance studies for which they were constructed, as well as for other experiments. A beam analysis system which will deliver high resolution beams to the MDM spectrometer is currently under construction. With the completion of these spectrometer projects, the facility emphasis is now focused on the development of the full capabilities of the K500 cyclotron and on the research program. During the report period, the ECR-K500 cyclotron combination operated 5,849 hours. Theoretical work reported in this document ranges from nuclear structure calculations using the IBM-2 model to calculations of kaon production and the in-medium properties of the rho and phi mesons, the latter as a probe of the QCD phase transition. Nuclear dynamics and exotic shapes and fragmentation modes of hot nuclei are also addressed. In atomic physics, new measurements of x-ray emission from highly ionized ions, of molecular dissociation and of surface interactions are reported.

  7. Development of a miniature microwave electron cyclotron resonance plasma ion thruster for exospheric micro-propulsion.

    Science.gov (United States)

    Dey, Indranuj; Toyoda, Yuji; Yamamoto, Naoji; Nakashima, Hideki

    2015-12-01

    A miniature microwave electron cyclotron resonance plasma source [(discharge diameter)/(microwave cutoff diameter) micro-propulsion applications in the exosphere. The discharge source uses both radial and axial magnetostatic field confinement to facilitate electron cyclotron resonance and increase the electron dwell time in the volume, thereby enhancing plasma production efficiency. Performance of the ion thruster is studied at 3 microwave frequencies (1.2 GHz, 1.6 GHz, and 2.45 GHz), for low input powers (<15 W) and small xenon mass flow rates (<40 μg/s), by experimentally measuring the extracted ion beam current through a potential difference of ≅1200 V. The discharge geometry is found to operate most efficiently at an input microwave frequency of 1.6 GHz. At this frequency, for an input power of 8 W, and propellant (xenon) mass flow rate of 21 μg/s, 13.7 mA of ion beam current is obtained, equivalent to an calculated thrust of 0.74 mN.

  8. A solvent-extraction module for cyclotron production of high-purity technetium-99m.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan

    2016-12-01

    The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99mTcO4-, in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na99mTcO4, purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99mTc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Improving cancer treatment with cyclotron produced radionuclides. Comprehensive progress report, February 1, 1992--July 15, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1995-07-17

    This research continues the long term goals of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. This program fits into the nuclear medicine component of DOE`s mission, which is aimed at enhancing the beneficial applications of radiation, radionuclides, and stable isotopes in the diagnosis, study and treatment of human diseases. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology/Immunology; and Imaging Physics. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Section under the DOE grant during the 1992--1995 will be employed in the Pharmacology/Immunology component in the period 1996--1999. Imaging Physics resolves relevant imaging related physics issues that arise during the experimentation that results. In addition to the basic research mission, this project also provides a basis for training of research scientists in radiochemistry, immunology, bioengineering and imaging physics.

  10. Electromagnetic Ion Cyclotron Waves in the High-Altitude Cusp: Polar Observations

    Science.gov (United States)

    Le, G.; Blanco-Cano, X.; Russell, C. T.; Zhou, X.-W.; Mozer, F.; Trattner, K. J.; Fuselier, S. A.; Anderson, B. J.

    2005-01-01

    High-resolution magnetic field data from the Polar Magnetic Field Experiment (MFE) show that narrow-band waves at frequencies approx. 0.2-3 Hz are a permanent feature in the vicinity of the polar cusp. The waves have been found in the magnetosphere adjacent to the cusp (both poleward and equatorward of the cusp) and in the cusp itself. The occurrence of waves is coincident with depression of magnetic field strength associated with enhanced plasma density, indicating the entry of magnetosheath plasma into the cusp region. The wave frequencies are generally scaled by the local proton cyclotron frequency and vary between 0.2 and 1.7 times local proton cyclotron frequency. This suggests that the waves are generated in the cusp region by the precipitating magnetosheath plasma. The properties of the waves are highly variable. The waves exhibit both left-handed and right-handed polarization in the spacecraft frame. The propagation angles vary from nearly parallel to nearly perpendicular to the magnetic field. We find no correlation among wave frequency, propagation angle, and polarization. Combined magnetic field and electric field data for the waves indicate that the energy flux of the waves is guided by the background magnetic field and points downward toward the ionosphere.

  11. Electromagnetic Ion Cyclotron Waves in the High Altitude Cusp: Polar Observations

    Science.gov (United States)

    Le, Guan; Blanco-Cano, X.; Russell, C. T.; Zhou, X.-W.; Mozer, F.; Trattner, K. J.; Fuselier, S. A.; Anderson, B. J.; Vondrak, Richard R. (Technical Monitor)

    2001-01-01

    High-resolution magnetic field data from the Polar Magnetic Field Experiment (MFE) show that narrow band waves at frequencies approximately 0.2 to 3 Hz are a permanent feature in the vicinity of the polar cusp. The waves have been found in the magnetosphere adjacent to the cusp (both poleward and equatorward of the cusp) and in the cusp itself. The occurrence of waves is coincident with depression of magnetic field strength associated with enhanced plasma density, indicating the entry of magnetosheath plasma into the cusp region. The wave frequencies are generally scaled by the local proton cyclotron frequency, and vary between 0.2 and 1.7 times local proton cyclotron frequency. This suggests that the waves are generated in the cusp region by the precipitating magnetosheath plasma. The properties of the waves are highly variable. The waves exhibit both lefthanded and right-handed polarization in the spacecraft frame. The propagation angles vary from nearly parallel to nearly perpendicular to the magnetic field. We find no correlation among wave frequency, propagation angle and polarization. Combined magnetic field and electric field data for the waves indicate that the energy flux of the waves is guided by the background magnetic field and points downward toward the ionosphere.

  12. Precision mass measurements using the Phase-Imaging Ion-Cyclotron-Resonance detection technique

    CERN Document Server

    Karthein, Jonas

    This thesis presents the implementation and improvement of the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) detection technique at the ISOLTRAP experiment, located at the ISOLDE / CERN, with the purpose of on-line high-precision and high-resolution mass spectrometry. Extensive simulation studies were performed with the aim of improving the phase-imaging resolution and finding the optimal position for detector placement. Following the outcome of these simulations, the detector was moved out of a region of electric-field distortion and closer to the center of the Penning trap, showing a dramatic improvement in the quality and reproducibility of the phase-imaging measurements. A new image reconstitution and analysis software for the MCP-PS detector was written in Python and ROOT and introduced in the framework of PI-ICR mass measurements. The state of the art in the field of time-of-flight ion-cyclotron-resonance measurements is illustrated through an analysis of on-line measurements of the mirror nuclei $...

  13. NuSTAR Discovery of a Cyclotron Line in KS 1947+300

    Science.gov (United States)

    Furst, Felix; Pottschmidt, Katja; Wilms, Jorn; Kennea, Jamie; Bachetti, Matteo; Bellm, Eric; Boggs, Steven E.; Chakrabarty, Deepto; Christensen, Finn E.; Craig, William W.; hide

    2014-01-01

    We present a spectral analysis of three simultaneous Nuclear Spectroscopy Telescope Array and Swift/XRT observations of the transient Be-neutron star binary KS 1947+300 taken during its outburst in 2013/2014. These broadband observations were supported by Swift/XRTmonitoring snapshots every three days, which we use to study the evolution of the spectrum over the outburst.We find strong changes of the power-law photon index, which shows a weak trend of softening with increasing X-ray flux. The neutron star shows very strong pulsations with a period of P ˜ [almost equal to] 18.8 s. The 0.8-79 keV broadband spectrum can be described by a power law with an exponential cutoff and a blackbody component at low energies. During the second observation we detect a cyclotron resonant scattering feature at 12.5 keV, which is absent in the phase-averaged spectra of observations 1 and 3. Pulse phase-resolved spectroscopy reveals that the strength of the feature changes strongly with pulse phase and is most prominent during the broad minimum of the pulse profile. At the same phases the line also becomes visible in the first and third observation at the same energy. This discovery implies that KS 1947+300 has a magnetic field strength of B ˜ [almost equal to] 1.1 × 1012(1 + z) G, which is at the lower end of known cyclotron line sources.

  14. Ion cyclotron range of frequencies heating of plasma with small impurity production

    Science.gov (United States)

    Ohkawa, Tihiro

    1987-01-01

    Plasma including plasma ions is magnetically confined by a magnetic field. The plasma has a defined outer surface and is intersected by resonance surfaces of respective common ion cyclotron frequency of a predetermined species of plasma ions moving in the magnetic field. A radio frequency source provides radio frequency power at a radio frequency corresponding to the ion cyclotron frequency of the predetermined species of plasma ions moving in the field at a respective said resonance surface. RF launchers coupled to the radio frequency source radiate radio frequency energy at the resonance frequency onto the respective resonance surface within the plasma from a plurality of locations located outside the plasma at such respective distances from the intersections of the respective resonance surface and the defined outer surface and at such relative phases that the resulting interference pattern provides substantially null net radio frequency energy over regions near and including substantial portions of the intersections relative to the radio frequency energy provided thereby at other portions of the respective resonance surface within the plasma.

  15. Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron.

    Science.gov (United States)

    Kurashima, Satoshi; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Okumura, Susumu; Taguchi, Mitsumasa; Fukuda, Mitsuhiro

    2015-07-01

    The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.

  16. Low magnetic field cooling of lepton plasmas via cyclotron-cavity resonance

    Science.gov (United States)

    Hunter, E. D.; Evetts, N.; Fajans, J.; Hardy, W. N.; Landsberger, H.; Mcpeters, R.; Wurtele, J. S.

    2018-01-01

    Pure electron or pure positron plasmas held in magnetic fields B radiate energy because of the cyclotron motion of the plasma particles; nominally, the plasmas should cool to the often cryogenic temperatures of the trap in which they are confined. However, the cyclotron cooling rate for leptons is (1/4 s)(B/1 T)2, and significant cooling is not normally observed unless B ≳ 1 T . Cooling to the trap temperatures of ˜10 K is particularly difficult to attain. Here, we show that dramatically higher cooling rates (×100) and lower temperatures (÷1000) can be obtained if the plasmas are held in electromagnetic cavities rather than in effectively free space conditions. We find that plasmas with up to 107 particles can be cooled in fields close to 0.15 T, much lower than 1 T commonly thought to be necessary to obtain plasma cooling. Appropriate cavities can be constructed with only minor modifications to the standard Penning-Malmberg trap structures.

  17. Direct Technetium radiopharmaceuticals production using a 30MeV Cyclotron

    Science.gov (United States)

    Jalilian, AR.; Targholizadeh, H.; Raisali, GR.; Zandi, H.; Kamali Dehgan, M.

    2011-01-01

    Background and the purpose of the study Technetium-99m is the major radionuclide used in the world and mainly is provided by fission product. However extensive research has been conducted on the use of accelerators for production of 99mTc. This investigation reports the production of 99mTc radioisotope using cyclotrons and the preparation, quality control and biodistribution studies of four major Tc-radiopharmaceuticals. Methods The high purity molybdenum natural target (130 mg/cm2) was irradiated in a Cyclone 30 accelerator using 160 µA of 25 MeV proton beam energy for 1000 µA-h. After dissolution, the technetium radionuclides were extracted using methyl ethyl ketone (MEK) followed by preparation of Tc-MIBI, Tc-DTPA, Tc-DMSA and Tc-phytate as radiopharmaceutical samples. Results The results of quality controls and animal biodistribution studies showed successful production of Tc radionuclides (including 99mTc) in the bombarded target and subsequent labelling of the kit with Tc. Conclusion The developed high power Mo target if constructed using enriched 100Mo, could be a practical method for large-scale production of 99mTc and promising as an alternative to fission product 99Mo-99mTc generators for local applications near cyclotron facilities. PMID:22615656

  18. Cyclotron Production of (99m)Tc using (100)Mo2C targets.

    Science.gov (United States)

    Richards, Vernal N; Mebrahtu, Efrem; Lapi, Suzanne E

    2013-10-01

    An investigative study of the (100)Mo (p,2n)(99m)Tc reaction on a medical cyclotron using (100)Mo2C is reported. This is the first report of this compound being used as a target for this reaction. (100)Mo2C, a refractory carbide with high thermal conductivity, properties which underscore its use on a cyclotron, was synthesized using (100)MoO3. Its ease of oxidation back to (100)MoO3 under air at elevated temperatures facilitates the use of thermo-chromatography, a high temperature gas phase separation technique for the separation and isolation of (99m)Tc. Activity yields for (99m)Tc averaged 84% of the calculated theoretical yields. Additionally, the percent recovery of MoO3, the precursor for Mo2C, was consistently high at 85% ensuring a good life cycle for this target material. The produced (99m)Tc was radio-chemically pure and easily labeled MDP for imaging purposes. © 2013.

  19. Consequences of the Ion Cyclotron Instability in the Inner Magnetospheric Plasma

    Science.gov (United States)

    Khazanov, George V.

    2011-01-01

    The inner magnetospheric plasma is a very unique composition of different plasma particles and waves. Among these plasma particles and waves are Ring Current (RC) particles and Electromagnetic Ion Cyclotron (EMIC) waves. The RC is the source of free energy for the EMIC wave excitation provided by a temperature anisotropy of RC ions, which develops naturally during inward E x B convection from the plasma sheet. The cold plasmasphere, which is under the strong influence of the magnetospheric electric field, strongly mediates the RC-EMIC waves-coupling process, and ultimately becomes part of the particle and energy interplay, generated by the ion cyclotron instability of the inner magnetosphere. On the other hand, there is a strong influence of the RC on the inner magnetospheric electric and magnetic field configurations and these configurations, in turn, are important to RC dynamics. Therefore, one of the biggest needs for inner magnetospheric plasma physics research is the continued progression toward a coupled, interconnected system, with the inclusion of nonlinear feedback mechanisms between the plasma populations, the electric and magnetic fields, and plasma waves.

  20. On nonlinear Alfvén-cyclotron waves in multi-species plasma

    Science.gov (United States)

    Marsch, Eckart; Verscharen, Daniel

    2011-06-01

    Large-amplitude Alfvén waves are ubiquitous in space plasmas and a main component of magnetohydrodynamic (MHD) turbulence in the heliosphere. As pump waves, they are prone to parametric instability by which they can generate cyclotron and acoustic daughter waves. Here, we revisit a related process within the framework of the multi-fluid equations for a plasma consisting of many species. The nonlinear coupling of the Alfvén wave to acoustic waves is studied, and a set of compressive and coupled-wave equations for the transverse magnetic field and longitudinal electric field is derived for waves propagating along the mean-field direction. It turns out that slightly compressive Alfvén waves exert, through induced gyro-radius and kinetic-energy modulations, an electromotive force on the particles in association with a longitudinal electric field, which has a potential that is given by the gradient of the transverse kinetic energy of the particles gyrating about the mean field. This in turn drives electric fluctuations (sound and ion-acoustic waves) along the mean magnetic field, which can nonlinearly react back on the transverse magnetic field. Mutually coupled Alfvén-cyclotron-acoustic waves are thus excited, a nonlinear process that can drive a cascade of wave energy in the plasma, and may generate compressive microturbulence. These driven electric fluctuations might have consequences for the dissipation of an MHD turbulence and, thus, for the heating and acceleration of particles in the solar wind.

  1. Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Anindya, E-mail: r-ani@vecc.gov.in; Bhole, R. B.; Nandy, Partha P.; Yadav, R. C.; Pal, Sarbajit; Roy, Amitava [Variable Energy Cyclotron Centre, 1/AF Bidhan Nagar, Kolkata 700064 (India)

    2015-03-15

    The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.

  2. Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata

    Science.gov (United States)

    Roy, Anindya; Bhole, R. B.; Nandy, Partha P.; Yadav, R. C.; Pal, Sarbajit; Roy, Amitava

    2015-03-01

    The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.

  3. The electron-cyclotron maser instability as a source of plasma radiation. [Solar radio bursts

    Science.gov (United States)

    Winglee, R. M.; Dulk, G. A.

    1986-01-01

    The generation of continuum bursts from the sun at dm and m wavelengths (in particular, type IV bursts) via the electron-cyclotron-maser instability is examined. The maser instability can be driven by an electron distribution with either a loss-cone anisotropy or a peak at large pitch angles. For omega(p)/Omega(e) much greater than 1, the maser emission is produced by electrons interacting through a harmonic (cyclotron) resonance and is electrostatic, being in the upper hybrid mode at frequencies approximately equal to omega(p). Coalescence processes are required to convert the electrostatic waves into transverse radiation which can escape from the source region. Whether the resultant spectrum is nearly a smooth continuum or has a zebra-stripe pattern (both of which occur in type IV bursts) depends on the form of the electron distribution, inhomogeneities in the density and magnetic field, and whether the maser reaches saturation. For at least the case of some type IV dm bursts with fine structure, comparison with observations seems to indicate that the electrons producing the emission are more likely to have a loss-cone distribution, and that the maser instability is not at saturation.

  4. Conceptual design studies of the Electron Cyclotron launcher for DEMO reactor

    Science.gov (United States)

    Moro, Alessandro; Bruschi, Alex; Franke, Thomas; Garavaglia, Saul; Granucci, Gustavo; Grossetti, Giovanni; Hizanidis, Kyriakos; Tigelis, Ioannis; Tran, Minh-Quang; Tsironis, Christos

    2017-10-01

    A demonstration fusion power plant (DEMO) producing electricity for the grid at the level of a few hundred megawatts is included in the European Roadmap [1]. The engineering design and R&D for the electron cyclotron (EC), ion cyclotron and neutral beam systems for the DEMO reactor is being performed by Work Package Heating and Current Drive (WPHCD) in the framework of EUROfusion Consortium activities. The EC target power to the plasma is about 50 MW, in which the required power for NTM control and burn control is included. EC launcher conceptual design studies are here presented, showing how the main design drivers of the system have been taken into account (physics requirements, reactor relevant operations, issues related to its integration as in-vessel components). Different options for the antenna are studied in a parameters space including a selection of frequencies, injection angles and launch points to get the best performances for the antenna configuration, using beam tracing calculations to evaluate plasma accessibility and deposited power. This conceptual design studies comes up with the identification of possible limits, constraints and critical issues, essential in the selection process of launcher setup solution.

  5. Conceptual design studies of the Electron Cyclotron launcher for DEMO reactor

    Directory of Open Access Journals (Sweden)

    Moro Alessandro

    2017-01-01

    Full Text Available A demonstration fusion power plant (DEMO producing electricity for the grid at the level of a few hundred megawatts is included in the European Roadmap [1]. The engineering design and R&D for the electron cyclotron (EC, ion cyclotron and neutral beam systems for the DEMO reactor is being performed by Work Package Heating and Current Drive (WPHCD in the framework of EUROfusion Consortium activities. The EC target power to the plasma is about 50 MW, in which the required power for NTM control and burn control is included. EC launcher conceptual design studies are here presented, showing how the main design drivers of the system have been taken into account (physics requirements, reactor relevant operations, issues related to its integration as in-vessel components. Different options for the antenna are studied in a parameters space including a selection of frequencies, injection angles and launch points to get the best performances for the antenna configuration, using beam tracing calculations to evaluate plasma accessibility and deposited power. This conceptual design studies comes up with the identification of possible limits, constraints and critical issues, essential in the selection process of launcher setup solution.

  6. Long-term cyclotron dynamics of relativistic wave packets: Spontaneous collapse and revival

    Science.gov (United States)

    Demikhovskii, V. Ya.; Maksimova, G. M.; Perov, A. A.; Telezhnikov, A. V.

    2012-02-01

    In this work we study the effects of collapse and revival, as well as the zitterbewegung (ZB) phenomenon, for the relativistic electron wave packets, which are a superposition of the states with quantum numbers sharply peaked around some Landau level n0 of the order of few tens. The probability densities as well as average velocities of the packet center and the average spin components were calculated analytically and their evolution is visualized. Our computations demonstrate that due to the dephasing of the states for times larger than the cyclotron period the initial wave packet (which includes the states with the positive energy only) loses the spatial localization so that the evolution can no longer be described classically. However, at the half-revival time t=TR/2 its reshaping takes place first. It is shown that the behavior of the wave packet containing the states of both energy bands (with En>0 and Ennegative energy) restores at various points of the cyclotron orbit, which makes reshaping of the initial wave packet impossible, entirely unlike the wave packet which consists of states with energies En>0 only. The obtained results can be useful for the description of electromagnetic radiation and absorption in relativistic plasma on astrophysics objects, where superhigh magnetic field has a value of the order 108-109T, as well as for interpretation of experiments with trapped ions.

  7. Theory and observations of electromagnetic ion cyclotron waves in Saturn's inner magnetosphere

    Science.gov (United States)

    Barbosa, D. D.

    1993-01-01

    High-resolution Voyager 1 magnetic field observations of Saturn's inner magnetosphere are examined for the presence of ULF waves. Quasi-circular left-hand polarized transverse oscillations are found in the near-equatorial region of 5-7 Rs with a wave period about 10 s and peak amplitude of about 2 nT. The wave is identified as the electromagnetic oxygen cyclotron mode occurring at a frequency just below the O(+) ion cyclotron frequency. A theoretical model of wave excitation based on gyroresonant coupling through a temperature anisotropy of O(+) pickup ions is developed which accounts for the principal features of the wave spectrum. It is hypothesized that wave-particle interactions provide a level of scattering commensurate with the weak pitch angle diffusion regime but nonetheless one that regulates and maintains a constant thermal anisotropy of ions along the magnetic field. Arguments are also presented that O(+) was the dominant thermal ion of the Dione-Tethys plasma torus at the time of the Pioneer 11 encounter the year previous to the Voyager 1 measurements.

  8. Production of hydrogen and deuterium negative ions in an electron cyclotron resonance driven plasma

    Energy Technology Data Exchange (ETDEWEB)

    Dougar-Jabon, V.D. [Industrial Univ. of Santander, Bucaramanga (Colombia)

    2001-04-01

    An electron cyclotron resonance source with driven plasma rings for hydrogen isotope ion production is studied. Extracted currents of positive and negative ions depending on gas pressure, microwave power value and extraction voltage are obtained. The study shows that the negative ion yield is an order of magnitude higher than the yield of positive particles when a driven ring is in contact with the surface of the plasma electrode. The production of negative ions of deuterium, D{sup -}, is close to the production of negative ions of light hydrogen isotope, H{sup -}. The comparison of the experimental data with the calculated ones shows that the most probable process of the H{sup -} and D{sup -} ion formation in the electron cyclotron driven plasma is dissociative attachment of electrons to molecules in high Rydberg states. For hydrogen ions and ions of deuterium, the negative current at a microwave power of 200 W through a 3-mm aperture and 8 kV extraction voltage are 4.7 mA and 3.1 mA respectively. (orig.)

  9. Accelerated Learning: Undergraduate Research Experiences at the Texas A&M Cyclotron Institute

    Science.gov (United States)

    Yennello, S. J.

    The Texas A&M Cyclotron Institute (TAMU CI) has had an NSF funded Research Experiences for Undergraduates program since 2004. Each summer about a dozen students from across the country join us for the 10-week program. They are each imbedded in one of the research groups of the TAMU CI and given their own research project. While the main focus of their effort is their individual research project, we also have other activities to broaden their experience. For instance, one of those activities has been involvement in a dedicated group experiment. Because not every experimental group will run during those 10 weeks and the fact that some of the students are in theory research groups, a group research experience allows everyone to actually be involved in an experiment using the accelerator. In stark contrast to the REU students' very focused experience during the summer, Texas A&M undergraduates can be involved in research projects at the Cyclotron throughout the year, often for multiple years. This extended exposure enables Texas A&M students to have a learning experience that cannot be duplicated without a local accelerator. The motivation for the REU program was to share this accelerator experience with students who do not have that opportunity at their home institution.

  10. Assessment of single-turn extraction for a superconducting separated-sector cyclotron

    Directory of Open Access Journals (Sweden)

    J.-W. Kim

    1999-04-01

    Full Text Available We have studied the beam dynamics in a high field separated-sector cyclotron to establish conditions required to achieve single-turn extraction. Extraction efficiency above 99% is aimed to avoid beam-induced damages. A sufficient last-turn separation and a preservation of beam quality throughout the acceleration are the prerequisites. The last-turn separation can be enhanced with the orbital precession induced by an off-centering injection as in existent lower field separated-sector cyclotrons. The beam qualities, on the other hand, are affected by the resonances traversed or approached during the acceleration. Acceleration of light nuclei to the energies of 300–400 MeV/u was especially disturbing because of the broadening of radial beamwidth upon crossing the ν_{r}=3/2 resonance. Tolerance to the third harmonic gradient field, which causes the resonance in lowest order, is set to be 0.1 G/cm. The integer resonance ν_{z}=1 can be avoided with a proper design of the yoke. The longitudinal space charge forces were also investigated to estimate the intensity limits determined by the energy spreads of beam assuming simplified charge distributions. Moreover, beam preparations for injection matching are described in view of reducing the beam losses into the extraction elements.

  11. Cyclotron production of {sup 64}Cu by deuteron irradiation of {sup 64}Zn

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, K. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (Vatican City State, Holy See,) (Italy)]. E-mail: kamel.abbas@jrc.it; Kozempel, J. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy); Charles University Prague, Faculty of Science, Department of Organic and Nuclear Chemistry, 128 43 Prague (Czech Republic); Bonardi, M. [LASA, Radiochemistry Laboratory, University and INFN, via F.lli Cervi 201, I-20090 Segrate (MI) (Italy); Groppi, F. [LASA, Radiochemistry Laboratory, University and INFN, via F.lli Cervi 201, I-20090 Segrate (MI) (Italy); Alfarano, A. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy); Holzwarth, U. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy); Simonelli, F. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy); Hofman, H. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy); Horstmann, W. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy); Menapace, E. [ENEA, Applied Physics Division, Bologna (Italy); Leseticky, L. [Charles University Prague, Faculty of Science, Department of Organic and Nuclear Chemistry, 128 43 Prague (Czech Republic); Gibson, N. [Institute for Health and Consumer Protection, Joint Research Centre, European Commission, TP 500, I-21020 Ispra (VA) (Italy)

    2006-09-15

    The short-lived (12.7 h half-life) {sup 64}Cu radioisotope is both a {beta} {sup +} and a {beta} {sup -} emitter. This property makes {sup 64}Cu a promising candidate for novel medical applications, since it can be used simultaneously for therapeutic application of radiolabelled biomolecules and for diagnosis with PET. Following previous work on {sup 64}Cu production by deuteron irradiation of natural zinc, we report here the production of this radioisotope by deuteron irradiation of enriched {sup 64}Zn. In addition, yields of other radioisotopes such as {sup 61}Cu, {sup 67}Cu, {sup 65}Zn, {sup 69m}Zn, {sup 66}Ga and {sup 67}Ga, which were co-produced in this process, were also measured. The evaporation code ALICE-91 and the transport code SRIM 2003 were used to determine the excitation functions and the stopping power, respectively. All the nuclear reactions yielding the above-mentioned radioisotopes were taken into account in the calculations both for the natural and enriched Zn targets. The experimental and calculated yields were shown to be in reasonable agreement. The work was carried out at the Scanditronix MC-40 Cyclotron of the Institute for Health and Consumer Protection of the Joint Research Centre of the European Commission (Ispra site, Italy). The irradiations were carried out with 19.5 MeV deuterons, the maximum deuteron energy obtainable with the MC-40 cyclotron.

  12. Direct Technetium radiopharmaceuticals production using a 30MeV Cyclotron

    Directory of Open Access Journals (Sweden)

    M Kamali Dehgan

    2011-07-01

    Full Text Available Background and purpose of the study: Technetium-99m is the major radionuclide used in the world and mainly is provided by fission product. However extensive research has been conducted on the use of accelerators for production of 99mTc. This investigation reports the production of 99mTc radioisotope using cyclotrons followed by the preparation, quality control and biodistribution studies of four major Tc-radiopharmaceuticals. Methods: The high purity molybdenum natural target (130mg/cm2 was irradiated in a Cyclone 30 accelerator using 160 µA of 25 MeV proton beam energy for 1000 µA-h. After dissolution, the technetium radionuclides were extracted using methyl ethyl ketone (MEK followed by preparation of Tc-MIBI, Tc-DTPA, Tc-DMSA and Tc-phytate as radiopharmaceutical samples. Results: The results of quality controls and animal biodistribution studies showed successful production of Tc radionuclides (including 99mTc in the bombarded target and subsequent labelling of the kit with Tc. Conclusion: The developed high power Mo target if constructed using enriched 100Mo, could be a practical method for large-scale production of 99mTc and promising as an alternative to fission product 99Mo-99mTc generators for local applications near cyclotron facilities.

  13. Analysis of MMS observations of Ion Cyclotron Waves in the Magnetosheath

    Science.gov (United States)

    Boardsen, S. A.; Vinas, A. F.; Gershman, D. J.; Dorelli, J.; Bellan, P. M.; Wendel, D. E.; Avanov, L. A.; Barrie, A. C.; Giles, B. L.; Moore, T. E.; Paterson, W. R.; Pollock, C.; Le, G.; Russell, C. T.; Fuselier, S. A.; Strangeway, R. J.; Torbert, R. B.; Burch, J. L.

    2016-12-01

    We will analyze magnetosheath ion cyclotron waves observed by the Magnetospheric Multiscale (MMS) Spacecraft. One such event occurred on October 7, 2016, in which strong ion cyclotron waves were observed in the magnetosheath, near the bowshock, lasting for 1 hour. We will perform a detailed wave analysis of this and similar events, comparing and contrasting single spacecraft and multi-spacecraft analysis techniques. The later will consist of a) Balikhin's phase difference method, b) Bellan's k-spectral plasma current method, and c) k-Filtering multi-spacecraft technique. For the identified wave mode based on these techniques, the self-consistency between the ion/electron fluctuations and the electric and magnetic field fluctuations of these waves will be explored. No Fast Plasma Investigation burst mode data exists for these events, so trigger data, which is at the same temporal resolution as that of the burst mode will be used to compare the ion/electron fluctuations with that of the electric and magnetic fields

  14. The Berkeley accelerator space effects facility (BASE) - A newmission for the 88-inch cyclotron at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, M.A.

    2005-09-06

    In FY04, the 88-Inch Cyclotron began a new operating mode that supports a local research program in nuclear science, R&D in accelerator technology and a test facility for the National Security Space (NSS) community (the U.S. Air Force and NRO). The NSS community (and others on a cost recovery basis) can take advantage of both the light- and heavy-ion capabilities of the Cyclotron to simulate the space radiation environment. A significant portion of this work involves the testing of microcircuits for single event effects. The experimental areas within the building that are used for the radiation effects testing are now called the Berkeley Accelerator and Space Effects (BASE) facility. Improvements to the facility to provide increased reliability, quality assurance and new capabilities are underway and will be discussed. These include a 16 AMeV ''cocktail'' of beams for heavy ion testing, a neutron beam, more robust dosimetry, and other upgrades.

  15. Spatial dependence of electromagnetic ion cyclotron waves triggered by solar wind dynamic pressure enhancements

    Science.gov (United States)

    Cho, J.-H.; Lee, D.-Y.; Noh, S.-J.; Kim, H.; Choi, C. R.; Lee, J.; Hwang, J.

    2017-05-01

    In this paper, using the multisatellite (the Van Allen Probes and two GOES satellites) observations in the inner magnetosphere, we examine two electromagnetic ion cyclotron (EMIC) wave events that are triggered by Pdyn enhancements under prolonged northward interplanetary magnetic field quiet time preconditions. For both events, the impact of enhanced Pdyn causes EMIC waves at multiple points. However, we find a strong spatial dependence that EMIC waves due to enhanced Pdyn impact can occur at multiple points (likely globally but not necessarily everywhere) but with different wave properties. For Event 1, three satellites situated at a nearly same dawnside zone but at slightly different L shells see occurrence of EMIC waves but in different frequencies relative to local ion gyrofrequencies and with different polarizations. These waves are found inside or at the outer edge of the plasmasphere. Another satellite near noon observes no dramatic EMIC wave despite the strongest magnetic compression there. For Event 2, the four satellites are situated at widely separated magnetic local time zones when they see occurrence of EMIC waves. They are again found at different frequencies relative to local ion gyrofrequencies with different polarizations and all outside the plasmasphere. We propose two possible explanations that (i) if triggered by enhanced Pdyn impact, details of ion cyclotron instability growth can be sensitive to local plasma conditions related to background proton distributions, and (ii) there can be preexisting waves with a specific spatial distribution, which determines occurrence and specific properties of EMIC waves depending on satellite's relative position after an enhanced Pdyn arrives.

  16. Shielding for a cyclotron used for medical isotope production in China.

    Science.gov (United States)

    Pevey, R; Miller, L F; Marshall, B J; Townsend, L W; Alvord, B

    2005-01-01

    Monte Carlo and discrete ordinate calculations have been performed to determine the doses at several locations in a positron emission tomography (PET) facility in China, where the radiation source is a cyclotron that is used for the production of the isotopes necessary for PET scans. The energy-dependent neutron source term is obtained by calculations using the ALICE code, and is interpolated for input to Monte Carlo and discrete ordinate calculations. The building that houses the cyclotron has a labyrinth of walls to minimise dose to operators and to other occupants of the building. Unbiased Monte Carlo calculations did not converge after more than one week of CPU time, whereas direction biasing alone resulted in convergence in several days. A study of several biasing techniques indicated that about a factor of 3 in computational efficiency is obtained using evaluated biasing methods. The use of adjoint fluxes for biasing Monte Carlo calculations can improve computational efficiencies by one or two orders of magnitude for some problems.

  17. Extension of electron cyclotron heating at ASDEX Upgrade with respect to high density operation

    Science.gov (United States)

    Schubert, Martin; Stober, Jörg; Herrmann, Albrecht; Kasparek, Walter; Leuterer, Fritz; Monaco, Francesco; Petzold, Bernhard; Plaum, Burkhard; Vorbrugg, Stefan; Wagner, Dietmar; Zohm, Hartmut

    2017-10-01

    The ASDEX Upgrade electron cyclotron resonance heating operates at 105 GHz and 140 GHz with flexible launching geometry and polarization. In 2016 four Gyrotrons with 10 sec pulse length and output power close to 1 MW per unit were available. The system is presently being extended to eight similar units in total. High heating power and high plasma density operation will be a part of the future ASDEX Upgrade experiment program. For the electron cyclotron resonance heating, an O-2 mode scheme is proposed, which is compatible with the expected high plasma densities. It may, however, suffer from incomplete single-pass absorption. The situation can be improved significantly by installing holographic mirrors on the inner column, which allow for a second pass of the unabsorbed fraction of the millimetre wave beam. Since the beam path in the plasma is subject to refraction, the beam position on the holographic mirror has to be controlled. Thermocouples built into the mirror surface are used for this purpose. As a protective measure, the tiles of the heat shield on the inner column were modified in order to increase the shielding against unabsorbed millimetre wave power.

  18. Development of a low-level RF control system for PET cyclotron CYCIAE-14

    Science.gov (United States)

    Li, Pengzhan; Yin, Zhiguo; Ji, Bin; Zhang, Tianjue; Zhao, Zhenlu

    2014-01-01

    The project of a 14 MeV PET cyclotron aiming at medical diagnosis and treatment was proposed and started at CIAE in 2010. The low-level RF system is designed to stabilize acceleration voltage and control the resonance of the cavity. Based on the experience of the existing CRM Cyclotron in CIAE, a new start-up sequence is developed and tested. The frequency sweeping is used to activate the RF system. Before the tuner is put into use, a new state called "DDS tuning" is applied to trace the resonance frequency to the designed value. This new option state helps to cover the tuning range, if a large frequency variation occurs because of a thermal cavity deformation. The logic control unit detects the spark, reflection, Pulse/CW state and the frequency of the RF source to perform all kinds of protection and state operations. The test bench and on-line test are carried out to verify the initial design.

  19. Extension of electron cyclotron heating at ASDEX Upgrade with respect to high density operation

    Directory of Open Access Journals (Sweden)

    Schubert Martin

    2017-01-01

    Full Text Available The ASDEX Upgrade electron cyclotron resonance heating operates at 105 GHz and 140 GHz with flexible launching geometry and polarization. In 2016 four Gyrotrons with 10 sec pulse length and output power close to 1 MW per unit were available. The system is presently being extended to eight similar units in total. High heating power and high plasma density operation will be a part of the future ASDEX Upgrade experiment program. For the electron cyclotron resonance heating, an O-2 mode scheme is proposed, which is compatible with the expected high plasma densities. It may, however, suffer from incomplete single-pass absorption. The situation can be improved significantly by installing holographic mirrors on the inner column, which allow for a second pass of the unabsorbed fraction of the millimetre wave beam. Since the beam path in the plasma is subject to refraction, the beam position on the holographic mirror has to be controlled. Thermocouples built into the mirror surface are used for this purpose. As a protective measure, the tiles of the heat shield on the inner column were modified in order to increase the shielding against unabsorbed millimetre wave power.

  20. Enhanced Physicochemical and Biological Properties of Ion-Implanted Titanium Using Electron Cyclotron Resonance Ion Sources

    Directory of Open Access Journals (Sweden)

    Csaba Hegedűs

    2016-01-01

    Full Text Available The surface properties of metallic implants play an important role in their clinical success. Improving upon the inherent shortcomings of Ti implants, such as poor bioactivity, is imperative for achieving clinical use. In this study, we have developed a Ti implant modified with Ca or dual Ca + Si ions on the surface using an electron cyclotron resonance ion source (ECRIS. The physicochemical and biological properties of ion-implanted Ti surfaces were analyzed using various analytical techniques, such as surface analyses, potentiodynamic polarization and cell culture. Experimental results indicated that a rough morphology was observed on the Ti substrate surface modified by ECRIS plasma ions. The in vitro electrochemical measurement results also indicated that the Ca + Si ion-implanted surface had a more beneficial and desired behavior than the pristine Ti substrate. Compared to the pristine Ti substrate, all ion-implanted samples had a lower hemolysis ratio. MG63 cells cultured on the high Ca and dual Ca + Si ion-implanted surfaces revealed significantly greater cell viability in comparison to the pristine Ti substrate. In conclusion, surface modification by electron cyclotron resonance Ca and Si ion sources could be an effective method for Ti implants.

  1. A BaF2 crystal array for high energy-ray measurements

    Indian Academy of Sciences (India)

    Abstract. We shall discuss about the scientific motivation and construction of a 7 × 7 BaF2 crystal array at Variable Energy Cyclotron Centre, Calcutta. This detector would be used to measure high energy -ray photons from GDR decay and proton–neutron bremsstrahlung reactions at the present 88'' cyclotron and upcoming ...

  2. Magnetic field and dimensionality-induced population effects in HgSe : Fe quantum wells: the cyclotron resonance

    Science.gov (United States)

    Portugall, O.; Barczewski, M.; von Ortenberg, M.; Schikora, D.; Widmer, T.; Lischka, H.

    1998-02-01

    Line shapes of the high-field cyclotron resonance are investigated both experimentally and theoretically for thin layers of the Fermi-level pinned system HgSe : Fe. Characteristic features are related to a subband population representing the two- and three-dimensional limits as well as intermediate steps.

  3. Effect of finite ωτ on cyclotron-wave propagation in metals in the long-wavelength limit

    DEFF Research Database (Denmark)

    Frandsen, J. B.; Gordon, R A

    1976-01-01

    Exact calculations of cyclotron-wave dispersion curves have been carried out for a degenerate free-electron metal including finite relaxation time effects. The calculated dispersion curves are shown to differ substantially from the experimental dispersion curves in the long-wavelength limit...

  4. Metal impurity transport control in JET H-mode plasmas with central ion cyclotron radiofrequency power injection

    DEFF Research Database (Denmark)

    Valisa, M.; Carraro, L.; Predebon, I.

    2011-01-01

    The scan of ion cyclotron resonant heating (ICRH) power has been used to systematically study the pump out effect of central electron heating on impurities such as Ni and Mo in H-mode low collisionality discharges in JET. The transport parameters of Ni and Mo have been measured by introducing a t...

  5. Design of the ITER upper port electron cyclotron heating and current drive system based on remote steering

    NARCIS (Netherlands)

    M. F. Graswinckel,; van den Berg, M. A.; Bongers, W. A.; Donne, A. J. H.; Goede, A. P. H.; Cardozo, N. L.; Ronden, D. M. S.; Verhoeven, A. G. A.

    2008-01-01

    A design is presented for the electron cyclotron (EC) heating and current drive system of the ITER upper port launchers based on the remote steering (RS) concept. In this concept the millimeter-wave beam is steered by a mirror that is located at the back end of the launcher waveguide. The RS concept

  6. Main-ion temperature and plasma rotation measurements based on scattering of electron cyclotron heating waves in ASDEX Upgrade

    DEFF Research Database (Denmark)

    Pedersen, Morten Stejner; Rasmussen, Jesper; Nielsen, Stefan Kragh

    2017-01-01

    We demonstrate measurements of spectra of O-mode electron cyclotron resonance heating (ECRH) waves scattered collectively from microscopic plasma fluctuations in ASDEX Upgrade discharges with an ITER-like ECRH scenario. The measured spectra are shown to allow determination of the main ion...

  7. Steps Towards a 3 mA, 1.8 MW Proton Beam at the PSI Cyclotron Facility

    CERN Document Server

    Schmelzbach, Pierre A; Adelmann, Andreas; Fitze, Hansruedi; Heidenreich, Gerd; Raguin, Jean-Yves; Rohrer, Urs; Sigg, Peter K

    2005-01-01

    The PSI Cyclotron Facility produces routinely a 1.8-1.9 mA proton beam at 590 MeV. The beam power reaches 1.1 MW at the the pion production targets and 0.7 MW at the neutron spallation target SINQ. The accelerator complex will be analysed in respect to his potential for future improvements. The ongoing developments aiming to increase the beam intensity to 3 mA and hence the beam power to 1.8 MW will be discussed. Smooth extrapolations of the observed machine parameters as well as recent advances in the theoretical treatment of space charge dominated beams show that this goal can be achieved with available technologies. IA new RF-cavity operated at a voltage in excess of 1 MV has been successfully tested and installed in the Ring Cyclotron. Bunchers for the low energy and the medium energy transfer lines are in the design phase. A conceptual study of new accelerating cavities to replace the obsolete flattop-cavities of the Injector Cyclotron has been performed. While the upgrade of the Ring Cyclotron with four...

  8. Three-dimensional simulations of ion dynamics in the plasma of an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Mironov, V.; Beijers, J.P.M.

    The ion production in an electron cyclotron resonance ion source (ECRIS) is modeled using a particle-in-cell Monte-Carlo-collision code in a three-dimensional geometry. Only the heavy particles (ions and atoms) are tracked, while the electrons are represented using a Maxwell-Boltzmann energy

  9. The ion cyclotron turbulence generated by a low frequency kinetic Alfven wave, and the related turbulent heating of ions

    Science.gov (United States)

    Mykhaylenko, Volodymyr S.; Mykhaylenko, Volodymyr V.; Lee, Hae June

    2017-10-01

    The ion cyclotron instability driven by the strong kinetic Alfven wave is investigated as a possible source of the anisotropic heating of ions in the coronal holes and solar wind. We present a novel model of a plasma with coupled inhomogeneous current and the sheared flow, which follows from the studies of the particles motion in the electric field of the kinetic Alfven wave of the finite wavelength. The investigation is performed employing the non-modal kinetic theory grounded on the shearing modes approach. The solution of the governing linear integral equation for the perturbed potential displays that the flow velocity shear, which for the corona conditions may be above the growth rate of the ion cyclotron instability in plasma with steady current, changes the exponential growth of the ion cyclotron potential on the power function of time, that impedes the growth of the unstable ion cyclotron wave and reduces the turbulent heating rate of ions across the magnetic field. This work was funded by National R&D Program through the National Research Foundation of Korea (NRF) (Grant No. NRF-2015R1D1A1A01061160).

  10. Impact of Ring Current Ions on Electromagnetic Ion Cyclotron Wave Dispersion Relation

    Science.gov (United States)

    Khazanov, G. V.; Gamayunov, K. V.

    2007-01-01

    Effect of the ring current ions in the real part of electromagnetic ion Cyclotron wave dispersion relation is studied on global scale. Recent Cluster observations by Engebretson et al. showed that although the temperature anisotropy of is energetic (> 10 keV) ring current protons was high during the entire 22 November 2003 perigee pass, electromagnetic ion cyclotron waves were observed only in conjunction with intensification of the ion fluxes below 1 keV by over an order of magnitude. To study the effect of the ring current ions on the wave dispersive properties and the corresponding global wave redistribution, we use a self-consistent model of interacting ring current and electromagnetic ion cyclotron waves, and simulate the May 1998 storm. The main findings of our simulation can be summarized as follows: First, the plasma density enhancement in the night MLT sector during the main and recovery storm phases is mostly caused by injection of suprathermal plasma sheet H + (approximately wave dispersion relation leads to a qualitative change of the wave patterns in the postmidnight-dawn sector for L > 4.75. This "new" wave activity is well organized by outward edges of dense suprathermal ring current spots, and the waves are not observed if the ring current ions are not included in the real part of dispersion relation. Third, the most intense wave-induced ring current precipitation is located in the night MLT sector and caused by modification of the wave dispersion relation. The strongest precipitating fluxes of about 8 X 10(exp 6)/ (cm(exp 2) - s X st) are found near L=5.75, MLT=2 during the early recovery phase on 4 May. Finally, the nightside precipitation is more intense than the dayside fluxes, even if there are less intense waves, because the convection field moves ring current ions into the loss cone on the nightside, but drives them out of the loss cone on the dayside. So convection and wave scattering reinforce each other in the nightside, but interfere in

  11. Residual radioactivity at the CERN 600 MeV synchro-cyclotron

    Science.gov (United States)

    Carbonez, P.; La Torre, F. P.; Michaud, R.; Silari, M.

    2012-12-01

    The 600 MeV synchro-cyclotron (SC) was the first accelerator that came into operation at CERN in 1957. It provided beams for CERN's first particle and nuclear physics experiments and operated for 33 years until it was shut down in 1990. In view of a planned partial decommissioning of the facility, a range of measurements were carried out to evaluate the levels of residual radioactivity in the accelerator and its surrounding after about 20 years of cooling time. Gamma spectrometry measurements were performed on 113 samples collected inside the three floors of the accelerator vault, on the cyclotron itself and on concrete samples taken from various parts of the building walls, up to a depth of 50 cm in the shield. About 40% of all samples contain traces of neutron-induced radionuclides, mainly 60Co (in metals), 133Ba, 137Cs, 152Eu and 154Eu (in concrete). Values of specific activities range from 5 mBq/g to 781 Bq/g. The maximum activity induced in concrete was observed at the depth of 40 cm in the wall near the cyclotron extraction channel. The laboratory measurements were supplemented by in-situ gamma spectrometry performed with the ISOCS system. A complete dose rate survey was also performed yielding isodose maps of the three levels of the building. The isotope production and the residual radioactivity in the barite walls of the SC bunker were simulated with the FLUKA and JEREMY codes in use at CERN for predicting residual radioactivity in activated accelerator components, and the results compared with the gamma spectrometry data. A detailed comparison of calculated and measured specific activities shows generally good agreement, to within a factor 2 in most cases. These results serve as indirect validation of the capabilities of these codes to correctly predict residual radioactivity with only a very approximate knowledge of the irradiation profile and after a very long (20 years) cooling time. Overall the results provided in this paper may be of use for

  12. STEREO and Wind Observations of Intense Cyclotron Harmonic Waves at the Earth's Bow Shock and Inside the Magnetosheath

    Science.gov (United States)

    Breneman, A. W.; Cattell, C.

    2013-01-01

    We present the first observations of electron cyclotron harmonic waves at the Earth's bow shock from STEREO and Wind burst waveform captures. These waves are observed at magnetic field gradients at a variety of shock geometries ranging from quasi-parallel to nearly perpendicular along with whistler mode waves, ion acoustic waves, and electrostatic solitary waves. Large amplitude cyclotron harmonic waveforms are also observed in the magnetosheath in association with magnetic field gradients convected past the bow shock. Amplitudes of the cyclotron harmonic waves range from a few tens to more than 500 millivolts/meter peak-peak. A comparison between the short (15 meters) and long (100 meters) Wind spin plane antennas shows a similar response at low harmonics and a stronger response on the short antenna at higher harmonics. This indicates that wavelengths are not significantly larger than 100 meters, consistent with the electron cyclotron radius. Waveforms are broadband and polarizations are distinctively comma-shaped with significant power both perpendicular and parallel to the magnetic field. Harmonics tend to be more prominent in the perpendicular directions. These observations indicate that the waves consist of a combination of perpendicular Bernstein waves and field-aligned waves without harmonics. A likely source is the electron cyclotron drift instability which is a coupling between Bernstein and ion acoustic waves. These waves are the most common type of high-frequency wave seen by STEREO during bow shock crossings and magnetosheath traversals and our observations suggest that they are an important component of the high-frequency turbulent spectrum in these regions.

  13. Restoration of accelerator facilities damaged by Great East Japan Earthquake at Cyclotron and Radioisotope Center, Tohoku University.

    Science.gov (United States)

    Wakui, Takashi; Itoh, Masatoshi; Shimada, Kenzi; Yoshida, Hidetomo P; Shinozuka, Tsutomu; Sakemi, Yasuhiro

    2014-08-01

    The Cyclotron and Radioisotope Center (CYRIC) of Tohoku University is a joint-use institution for education and research in a wide variety of fields ranging from physics to medicine. Accelerator facilities at the CYRIC provide opportunities for implementing a broad research program, including medical research using positron emission tomography (PET), with accelerated ions and radioisotopes. At the Great East Japan Earthquake on March 11, 2011, no human injuries occurred and a smooth evacuation was made in the CYRIC, thanks to the anti-earthquake measures such as the renovation of the cyclotron building in 2009 mainly to provide seismic strengthening, fixation of shelves to prevent the falling of objects, and securement of the width of the evacuation route. The preparation of an emergency response manual was also helpful. However, the accelerator facilities were damaged because of strong shaking that continued for a few minutes. For example, two columns on which a 930 cyclotron was placed were damaged, and thereby the 930 cyclotron was inclined. All the elements of beam transport lines were deviated from the beam axis. Some peripheral devices in a HM12 cyclotron were broken. Two shielding doors fell from the carriage onto the floor and blocked the entrances to the rooms. The repair work on the accelerator facilities was started at the end of July 2011. During the repair work, the joint use of the accelerator facilities was suspended. After the repair work was completed, the joint use was re-started at October 2012, one and a half years after the earthquake.

  14. Accurate Monte Carlo modeling of cyclotrons for optimization of shielding and activation calculations in the biomedical field

    Science.gov (United States)

    Infantino, Angelo; Marengo, Mario; Baschetti, Serafina; Cicoria, Gianfranco; Longo Vaschetto, Vittorio; Lucconi, Giulia; Massucci, Piera; Vichi, Sara; Zagni, Federico; Mostacci, Domiziano

    2015-11-01

    Biomedical cyclotrons for production of Positron Emission Tomography (PET) radionuclides and radiotherapy with hadrons or ions are widely diffused and established in hospitals as well as in industrial facilities and research sites. Guidelines for site planning and installation, as well as for radiation protection assessment, are given in a number of international documents; however, these well-established guides typically offer analytic methods of calculation of both shielding and materials activation, in approximate or idealized geometry set up. The availability of Monte Carlo codes with accurate and up-to-date libraries for transport and interactions of neutrons and charged particles at energies below 250 MeV, together with the continuously increasing power of nowadays computers, makes systematic use of simulations with realistic geometries possible, yielding equipment and site specific evaluation of the source terms, shielding requirements and all quantities relevant to radiation protection. In this work, the well-known Monte Carlo code FLUKA was used to simulate two representative models of cyclotron for PET radionuclides production, including their targetry; and one type of proton therapy cyclotron including the energy selection system. Simulations yield estimates of various quantities of radiological interest, including the effective dose distribution around the equipment, the effective number of neutron produced per incident proton and the activation of target materials, the structure of the cyclotron, the energy degrader, the vault walls and the soil. The model was validated against experimental measurements and comparison with well-established reference data. Neutron ambient dose equivalent H*(10) was measured around a GE PETtrace cyclotron: an average ratio between experimental measurement and simulations of 0.99±0.07 was found. Saturation yield of 18F, produced by the well-known 18O(p,n)18F reaction, was calculated and compared with the IAEA recommended

  15. Quasilinear diffusion coefficients in a finite Larmor radius expansion for ion cyclotron heated plasmas

    Science.gov (United States)

    Lee, Jungpyo; Wright, John; Bertelli, Nicola; Jaeger, Erwin F.; Valeo, Ernest; Harvey, Robert; Bonoli, Paul

    2017-05-01

    In this paper, a reduced model of quasilinear velocity diffusion by a small Larmor radius approximation is derived to couple the Maxwell's equations and the Fokker Planck equation self-consistently for the ion cyclotron range of frequency waves in a tokamak. The reduced model ensures the important properties of the full model by Kennel-Engelmann diffusion, such as diffusion directions, wave polarizations, and H-theorem. The kinetic energy change ( W ˙ ) is used to derive the reduced model diffusion coefficients for the fundamental damping (n = 1) and the second harmonic damping (n = 2) to the lowest order of the finite Larmor radius expansion. The quasilinear diffusion coefficients are implemented in a coupled code (TORIC-CQL3D) with the equivalent reduced model of the dielectric tensor. We also present the simulations of the ITER minority heating scenario, in which the reduced model is verified within the allowable errors from the full model results.

  16. Adaptive-array Electron Cyclotron Emission diagnostics using data streaming in a Software Defined Radio system

    Science.gov (United States)

    Idei, H.; Mishra, K.; Yamamoto, M. K.; Hamasaki, M.; Fujisawa, A.; Nagashima, Y.; Hayashi, Y.; Onchi, T.; Hanada, K.; Zushi, H.; the QUEST Team

    2016-04-01

    Measurement of the Electron Cyclotron Emission (ECE) spectrum is one of the most popular electron temperature diagnostics in nuclear fusion plasma research. A 2-dimensional ECE imaging system was developed with an adaptive-array approach. A radio-frequency (RF) heterodyne detection system with Software Defined Radio (SDR) devices and a phased-array receiver antenna was used to measure the phase and amplitude of the ECE wave. The SDR heterodyne system could continuously measure the phase and amplitude with sufficient accuracy and time resolution while the previous digitizer system could only acquire data at specific times. Robust streaming phase measurements for adaptive-arrayed continuous ECE diagnostics were demonstrated using Fast Fourier Transform (FFT) analysis with the SDR system. The emission field pattern was reconstructed using adaptive-array analysis. The reconstructed profiles were discussed using profiles calculated from coherent single-frequency radiation from the phase array antenna.

  17. Improved system for perpendicular electron-cyclotron emission measurements on TMX-Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Lasnier, C.J.; Ellis, R.F.; James, R.A.

    1986-03-07

    Perpendicular electron-cyclotron emission (PECE) is used on TMX-U to diagnose thermal-barrier hot electrons (T/sub H/ approx. 100 to 400 keV); yielding the time history of the temperature of these relativistic electrons. We describe an improved quasi-optical viewing system for these measurements that uses high sensitivity superheterodyne receivers at fixed frequencies of 60, 98, 130, and 196 GHz. The improved viewing and transport system consists of an off-axis ellipsoidal mirror that images the plasma onto a V-band conical collection horn, an overmoded circular waveguide (7/8'' diam) that transports the radiation outside the vacuum vessel where the polarization is selected, and a high absorptivity Macor beam dump to prevent internal wall reflections from entering the viewing system. A relativistic code is used to calculate optically thin PECE signals from relativistic electrons for various energy and pitch angle distributions. 4 refs., 4 figs.

  18. Cyclotron produced {sup 67}Ga, a potential radionuclide for diagnostic and therapeutic applications

    Energy Technology Data Exchange (ETDEWEB)

    Khandaker, Mayeen Uddin, E-mail: mu-khandaker@um.edu.my; Kassim, Hasan Abu [Department of Physics, University of Malaya, 50603 Kuala Lumpur (Malaysia); Haba, Hiromitsu [Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0198 (Japan)

    2015-04-29

    Production cross-sections of the {sup nat}Zn(d,x){sup 67}Ga reactions have been measured from a 24-MeV deuteron energy down to the threshold by using a stacked-foil activation technique combined with HPGe γ-ray spectrometry. An overall good agreement is found with some of the earlier measurements, whereas a partial agreement is obtained with the theoretical data extracted from the TENDL-2013 library. Physical thick target yield for the {sup 67}Ga radionuclide was deduced using the measured cross-sections, and found in agreement with the directly measured yield available in the literature. This study reveals that a low deuteron energy (<11 MeV) cyclotron and an enriched {sup 66}Zn target could be used to obtain {sup 67}Ga in no carrier added form.

  19. Fourier transform ion cyclotron resonance versus time of flight for precision mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kouzes, R.T.

    1993-02-01

    Both Fourier Transform Ion Cyclotron Resonance and ICR Time-of-Flight mass spectroscopy (FTICR-MS and ICR-TOF-MS, respectively) have been applied to precision atomic mass measurements. This paper reviews the status of these approaches and compares their limitations. Comparisons are made of FTICR-MS and ICR-TOF-MS for application to precision atomic mass measurements of stable and unstable nuclei, where the relevant scale is an accuracy of 1 keV and where halflives are longer than 10 milliseconds (optimistically). The atomic mass table is built up from mass chains, and ICR-MS brings a method of producing new types of mass chains to the mass measurement arena.

  20. Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T., E-mail: uchida-t@toyo.jp [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Graduate School of Interdisciplinary New Science, Toyo University, Kawagoe 350-8585 (Japan); Rácz, R.; Biri, S. [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen (Hungary); Muramatsu, M.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, Suita 565-0871 (Japan); Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Faculty of Science and Engineering, Toyo University, Kawagoe 350-8585 (Japan)

    2016-02-15

    We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

  1. First results of the 2.45 GHz Oshima electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Asaji, T., E-mail: asaji@nc-toyama.ac.jp [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan); Nakamura, T.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Hitobo, T. [Tateyama Machine Co., Ltd., 30 Shimonoban, Toyama 930-1305 (Japan); Uchida, T. [Graduate School of Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Muramatsu, M. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2016-02-15

    A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.

  2. Lifetime of Ionic Vacancy Created in Redox Electrode Reaction Measured by Cyclotron MHD Electrode.

    Science.gov (United States)

    Sugiyama, Atsushi; Morimoto, Ryoichi; Osaka, Tetsuya; Mogi, Iwao; Asanuma, Miki; Miura, Makoto; Oshikiri, Yoshinobu; Yamauchi, Yusuke; Aogaki, Ryoichi

    2016-01-21

    The lifetimes of ionic vacancies created in ferricyanide-ferrocyanide redox reaction have been first measured by means of cyclotron magnetohydrodynamic electrode, which is composed of coaxial cylinders partly exposed as electrodes and placed vertically in an electrolytic solution under a vertical magnetic field, so that induced Lorentz force makes ionic vacancies circulate together with the solution along the circumferences. At low magnetic fields, due to low velocities, ionic vacancies once created become extinct on the way of returning, whereas at high magnetic fields, in enhanced velocities, they can come back to their initial birthplaces. Detecting the difference between these two states, we can measure the lifetime of ionic vacancy. As a result, the lifetimes of ionic vacancies created in the oxidation and reduction are the same, and the intrinsic lifetime is 1.25 s, and the formation time of nanobubble from the collision of ionic vacancies is 6.5 ms.

  3. Electron cyclotron resonance plasma reactor for production of carbon stripper foil

    Science.gov (United States)

    Faith Romero, Camille; Kanamori, Keita; Kinsho, Michikazu; Yoshimoto, Masahiro; Wada, Motoi

    2018-01-01

    A graphite antenna for the production of carbon-containing hydrogen plasmas is being developed to prepare impurity-free charge exchange foils for high-energy synchrotrons. Microwave power at 2.45 GHz frequency drives a coaxial structure antenna with a 12-mm-diameter central graphite cylinder and a tapered surrounding cylinder serving as the ground electrode. The antenna was placed in a linear magnetic field to investigate how it performs under an electron cyclotron resonance (ECR) condition. A clear resonance phenomenon was observed in plasma luminosity, microwave power absorption, and microwave power reflection when the induction current used to produce a linear magnetic field was changed. The antenna realized the best microwave coupling to the plasma with the ECR zone formed 5 mm from the end of the center electrode. The antenna realized stable operation for more than 5 h with 100 W input microwave power and with operating hydrogen pressure from 0.5 to 50 Pa.

  4. Demonstration of low energy proton radiography on an 11-MeV cyclotron

    Science.gov (United States)

    Zhang, Xiao Ding; Yang, Guo Jun; Li, Yi Ding; Wei, Tao; He, Xiaozhong; Zhao, Liang Chao; Zhang, Zhuo; Ma, Chaofan; Jiang, Xiaoguo; Shi, Jinshui

    2016-11-01

    Lens focused proton radiograph on thin objects is demonstrated using an 11-MeV proton cyclotron at China Academy of Engineering Physics. The proton beam exiting from the tested objects is focused onto the image plane by a magnetic lens system mitigating image blur caused by multiple Coulomb scattering. Both simulations and experiments show that clear images can be obtained with a lens system for the objects with thickness up to 2.7 × 10-2 g/cm2 and the error for the areal density measurement is measured to be less than 2.3%. For the objects with thickness between 2.7 × 10-3 g/cm2 and 2.7 × 10-2 g/cm2, 100-200 μm of spatial resolution is achieved.

  5. Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification.

    Science.gov (United States)

    Uchida, T; Rácz, R; Muramatsu, M; Kato, Y; Kitagawa, A; Biri, S; Yoshida, Y

    2016-02-01

    We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

  6. Weak-field H3O+ ion cyclotron resonance alters water refractive index.

    Science.gov (United States)

    D'Emilia, E; Ledda, M; Foletti, A; Lisi, A; Giuliani, L; Grimaldi, S; Liboff, A R

    2017-01-01

    Heretofore only observed in living systems, we report that weak-field ion cyclotron resonance (ICR) also occurs in inanimate matter. Weak magnetic field (50 nT) hydronium ICR at the field combination (7.84 Hz, 7.5 µT) markedly changes water structure, as evidenced by finding an altered index of refraction exactly at this combined field. This observation utilizes a novel technique which measures the scattering of a He-Ne laser beam as the sample is exposed to a ramped magnetic field frequency. In addition to the hydronium resonance, we find evidence of ICR coupling to a more massive structure, possibly a tetrahedral combination of three waters and a single hydronium ion. To check our observations, we extended this technique to D2O, successfully predicting the specific ICR charge-to-mass ratio for D3O+ that alters the index of refraction.

  7. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS.

    Science.gov (United States)

    Thomae, R; Conradie, J; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-02-01

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  8. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma.

    Science.gov (United States)

    Kato, Yushi; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu

    2016-02-01

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  9. Capabilities of the ITER Electron Cyclotron Equatorial Launcher for Heating and Current Drive

    Directory of Open Access Journals (Sweden)

    Ramponi G.

    2012-09-01

    Full Text Available The ITER Electron Cyclotron Equatorial Launcher is designed to be one of the heating systems to assist and sustain the development of various ITER plasma scenarios starting with the very first plasma operation. Here the capabilities for Heating and Current Drive of this system are reviewed. In particular, the optimum launching conditions are investigated for two scenarios at burn, comparing toroidal and poloidal steering options. Then, the EC capabilities are investigated for different plasma parameters corresponding to various phases of the ITER plasma discharge, from current ramp-up up to burn, and for a wide range of magnetic field, focusing in particular on the EC potential for heating and for L to H-mode assist. It is found that the EC system can contribute to a wide range of heating scenarios during the ramp-up of the magnetic field, significantly increasing the applicable range as a function of magnetic field.

  10. Modeling of electron cyclotron resonance acceleration in a stationary inhomogeneous magnetic field

    Directory of Open Access Journals (Sweden)

    Valeri D. Dougar-Jabon

    2008-04-01

    Full Text Available In this paper, the cyclotron autoresonance acceleration of electrons in a stationary inhomogeneous magnetic field is studied. The trajectory and energy of electrons are found through a numerical solution of the relativistic Newton-Lorentz equation by a finite difference method. The electrons move along a TE_{112} cylinder cavity in a steady-state magnetic field whose axis coincides with the cavity axis. The magnetic field profile is such that it keeps the phase difference between the electric microwave field and the electron velocity vector within the acceleration phase band. The microwaves amplitude of 6  kV/cm is used for numerical calculations. It is shown that an electron with an initial longitudinal energy of 8 keV can be accelerated up to 260 keV by 2.45 GHz microwaves at a distance of 17 cm.

  11. Stabilization of ion fishbone activities by electron cyclotron resonance heating in a toroidal plasma

    Science.gov (United States)

    Chen, W.; Yu, L. M.; Shi, P. W.; Ma, R.; Ji, X. Q.; Jiang, M.; Zhu, X. L.; Shi, Z. B.; Yu, D. L.; Yuan, B. S.; Li, Y. G.; Yang, Z. C.; Cao, J. Y.; Song, S. D.; Zhong, W. L.; He, H. D.; Dong, J. Q.; Ding, X. T.; Yan, L. W.; Liu, Yi.; Yang, Q. W.; Xu, M.; Duan, X. R.

    2018-01-01

    We report an experimental result on the stabilization of the energetic–ion driven internal kink mode (ion fishbone) by electron cyclotron resonance heating (ECRH), observed for the first time in a toroidal plasma. The mode asserts itself a resistive branch close to the marginal stability point. The resulting fishbone mode depends not only on the injected power but also on the radial deposition location of ECRH, and the instability can be completely suppressed when the injected ECRH power exceeds certain threshold. Analysis by the fishbone dispersion relation, including the resistive effect, suggests that the magnetic Reynolds number plays a key role in the mode stabilization—it weakens the mode growth-rate and enhances the critical energetic–ion beta without changing the energetic–ion population. This ion fishbone stabilization mechanism can be important for future devices such as ITER, which has significant ECRH capability.

  12. Dans l'oeil du cyclotron quand la haute technologie défie le cancer

    CERN Document Server

    Demard, François

    2016-01-01

    Cet ouvrage retrace l'histoire du cyclotron Medicyc, ce pionnier relativement méconnu de la protonthérapie en France qui permit à Nice le premier traitement d'un mélanome de l'oeil au centre Antoine Lacassagne. Fruit d'une étroite collaboration entre l'ingénieur et le médecin et, dès l'origine, dévolu à la radiothérapie des tumeurs et à la production de radio-isotopes médicaux. Aujourd'hui, quelques vingt-cinq ans plus tard, cette protonthérapie connaît un essor considérable dans le monde.

  13. A Proton-Cyclotron Wave Storm Generated by Unstable Proton Distribution Functions in the Solar Wind

    Science.gov (United States)

    Wicks, R. T.; Alexander, R. L.; Stevens, M.; Wilson, L. B., III; Moya, P. S.; Vinas, A.; Jian, L. K.; Roberts, D. A.; O’Modhrain, S.; Gilbert, J. A.; hide

    2016-01-01

    We use audification of 0.092 seconds cadence magnetometer data from the Wind spacecraft to identify waves with amplitudes greater than 0.1 nanoteslas near the ion gyrofrequency (approximately 0.1 hertz) with duration longer than 1 hour during 2008. We present one of the most common types of event for a case study and find it to be a proton-cyclotron wave storm, coinciding with highly radial magnetic field and a suprathermal proton beam close in density to the core distribution itself. Using linear Vlasov analysis, we conclude that the long-duration, large-amplitude waves are generated by the instability of the proton distribution function. The origin of the beam is unknown, but the radial field period is found in the trailing edge of a fast solar wind stream and resembles other events thought to be caused by magnetic field footpoint motion or interchange reconnection between coronal holes and closed field lines in the corona.

  14. Beam orbit simulation in the central region of the RIKEN AVF cyclotron

    CERN Document Server

    Toprek, D; Yano, Y

    1999-01-01

    This paper describes the modification design of the central region for h=2 mode of acceleration in the RIKEN AVF cyclotron. we made a small modification to the electrode shape in the central region for optimization of the beam transmission. The central region is equipped with an axial injection system. The spiral type inflector is used for axial injection. The electric field distribution in the inflector and in four acceleration gaps has been numerically calculated from an electric potential map produced by the program RELAX3D. The magnetic field is measured. The geometry of the central region has been tested with the computations of orbits carried out by means of the computer code CYCLONE. The optical properties of the spiral inflector and the central region are studied by using the program CASINO and CYCLONE, respectively. We have also made an effort to minimize the inflector fringe field effects using the RELAX3D program.

  15. Design of the central region in the Warsaw K-160 cyclotron

    CERN Document Server

    Toprek, D; Choinski, J; Czosnyka, T

    2001-01-01

    This paper describes the design of the central region for h=2 and 3 modes of acceleration in the Warsaw K-160 cyclotron. The central region is unique and compatible with the two above-mentioned harmonic modes of operation. Only one spiral type inflector will be used. The electric field distribution in the inflector and in the four acceleration gaps has been numerically calculated from an electric potential map produced by the program RELAX3D. The geometry of the central region has been tested with the computations of orbits carried out by means of the computer code CYCLONE. The optical properties of the spiral inflector and the central region were studied by using the programs CASINO and CYCLONE, respectively.

  16. Status of charge breeding with electron cyclotron resonance ion sources (invited)

    CERN Document Server

    Lamy, T; Sortais, P; Thuillier, T; 10.1063/1.2149300

    2006-01-01

    Due to the production methods of exotic nuclei, an efficient acceleration of radioactive ion beams needs charge breeding of weakly charged ions. The upgrade of existing isotope separator on-line facilities (TRIUMF-isotope separation and acceleration, CERN-isotope separation on-line detector, etc.) or the development of projects for the acceleration of radioactive ion beams (GANIL-SPIRAL2, MAFF, EURISOL, etc.) requires charge breeders with high efficiency, fast charge breeding time, low background levels, and high intensity acceptance either in continuous or in pulsed mode. The optimization of these parameters is a challenge for the electron cyclotron resonance (ECR) community and is useful to get a better understanding of plasma physics in ECR ion sources (ECRISs). The ECR charge breeding technique has been developed for more than ten years at LPSC (former ISN) Grenoble, typical 1+rightward arrown+ efficiencies are in the 3%-10% range depending on the nature of the incoming beam (metallic, alkaline, and gaseo...

  17. On-line capillary electrophoresis with Fourier transform ion cyclotron resonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hofstadler, S.A.; Wahl, J.H.; Bruce, J.E.; Smith, R.D. (Pacific Northwest Lab., Richland, WA (United States))

    1993-07-28

    The role of capillary electrophoresis (CE) in chemical and biochemical characterization is growing rapidly due to its speed, resolution, and flexibility for the manipulation of extremely small samples. CE was first combined with mass spectrometry (MS) at our laboratory. In this communication we report results for the first on-line combination of CE with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry, an approach that is capable of providing both high CE and MS resolution and high sensitivity. The advantages of FTICR include the ability to simultaneously realize ultrahigh MS resolution/mass measurement accuracy and high sensitivity, as well as the capability for higher order tandem MS methods (i.e., MS[sup n], where n [ge] 2) for structural studies because of its nondestructive detection method. 20 refs., 3 figs.

  18. Analytic fluid theory of beam spiraling in high-intensity cyclotrons

    Directory of Open Access Journals (Sweden)

    A. J. Cerfon

    2013-02-01

    Full Text Available Using a two-dimensional fluid description, we investigate the nonlinear radial-longitudinal dynamics of intense beams in isochronous cyclotrons in the nonrelativistic limit. With a multiscale analysis separating the time scale associated with the betatron motion and the slower time scale associated with space-charge effects, we show that the longitudinal-radial vortex motion can be understood in the frame moving with the charged beam as the nonlinear advection of the beam by the E×B velocity field, where E is the electric field due to the space charge and B is the external magnetic field. This interpretation provides simple explanations for the stability of round beams and for the development of spiral halos in elongated beams. By numerically solving the nonlinear advection equation for the beam density, we find that it is also in quantitative agreement with results obtained in particle-in-cell simulations.

  19. Poloidal rotation driven by electron cyclotron resonance wave in tokamak plasmas

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2017-10-01

    Full Text Available The poloidal electric filed, which is the drive field of poloidal rotation, has been observed and increases obviously after the injection of electron cyclotron resonance wave in HL-2A experiment, and the amplitude of the poloidal electric field is in the order of 103 V/m. Through theoretical analysis using Stringer rotation model, the observed poloidal electric field is of the same order as the theoretical calculation value. In addition, the magnetic pump damping which would damp the poloidal rotation is calculated numerically and the calculation results show that the closer to the core plasmas, the stronger the magnetic pump damping will be. Meanwhile, according to the value of the calculated magnetic pump damping, the threshold of the poloidal electric field which could overcome magnetic pump damping and drive poloidal rotation in tokamak plasmas is given out. Finally, the poloidal rotation velocity over time at different minor radius is studied theoretically.

  20. Ultrathin oxide grown on polysilicon by using an electron cyclotron resonance N sub 2 O plasma

    CERN Document Server

    Han, S Y

    2000-01-01

    We have developed a process for growing ultrathin oxide on a polysilicon layer by using an electron cyclotron resonance (ECR) N sub 2 O plasma. Sub-4-nm thick polyoxides were grown on n sup + and p sup + polysilicon layers and were characterized. These oxides had larger breakdown fields, smaller electron trapping characteristics, and larger Q sub B sub D values than those of thermal polyoxides. The electron trapping characteristics of ECR N sub 2 O plasma polyoxides, which were smaller than those of thermal polyoxides at positive bias, resulted from the smaller roughness of the polysilicon surface after the oxidation process. Under a negative constant-current stress of 20 mA/cm sup 2 for polyoxide on p sup + polysilicon were obtained. These ultrathin plasma polyoxides would be good candidates for future inter-poly dielectrics and gate oxides for thin film transistors.

  1. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  2. A relativistic model of electron cyclotron current drive efficiency in tokamak plasmas

    Directory of Open Access Journals (Sweden)

    Lin-Liu Y.R.

    2012-09-01

    Full Text Available A fully relativistic model of electron cyclotron current drive (ECCD efficiency based on the adjoint function techniques is considered. Numerical calculations of the current drive efficiency in a tokamak by using the variational approach are performed. A fully relativistic extension of the variational principle with the modified basis functions for the Spitzer function with momentum conservation in the electron-electron collision is described in general tokamak geometry. The model developed has generalized that of Marushchenko’s (N.B . Marushchenko, et al. Fusion Sci. & Tech., 2009, which is extended for arbitrary temperatures and covers exactly the asymptotic for u ≫ 1 when Z → ∞, and suitable for ray-tracing calculations.

  3. Cyclotron production of I-123: An evaluation of the nuclear reactions which produce this isotope

    Science.gov (United States)

    Sodd, V. J.; Scholz, K. L.; Blue, J. W.; Wellamn, H. N.

    1970-01-01

    The reactions studied which produce I-123 directly were Sb-121(He-4,2n) I-123, Sb-121(He-3,n) I-123, Te-122(d,n) I-123, Te-122(He-4,p2n) I-123, Te-122(He-3,pn) I-123, and Te-123(He-3,p2n) I-123. Reactions which produce I-123 indirectly through the positron decay of 2.1-hour Xe-123 were Te-122(He-4,3n) Xe-123, Te-122(He-3,2n) Xe-123 and Te-123(He-3,3n) Xe-123. Use of the gas flow I-123 cyclotron target assembly is recommended for the production of I-123 with radiochemical purity greater than 99.995%.

  4. On ion-cyclotron-resonance heating of the corona and solar wind

    Directory of Open Access Journals (Sweden)

    E. Marsch

    2003-01-01

    Full Text Available This paper concisely summarizes and critically reviews recent work by the authors on models of the heating of the solar corona by resonance of ions with high-frequency waves (up to the proton cyclotron frequency. The quasi-linear theory of pitch angle diffusion is presented in connection with relevant solar wind proton observations. Hybrid fluid-kinetic model equations, which include wave-particle interactions and collisions, are derived. Numerical solutions are discussed, representative of the inner corona and near-Sun solar wind. A semi-kinetic model for reduced velocity distributions is presented, yielding kinetic results for heavy ions in the solar corona. It is concluded that a self-consistent treatment of particle distributions and wave spectra is required, in order to adequately describe coronal physics and to obtain agreement with observations.

  5. Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic.

    Science.gov (United States)

    Rowan, W L; Houshmandyar, S; Phillips, P E; Austin, M E; Beno, J H; Hubbard, A E; Khodak, A; Ouroua, A; Taylor, G

    2016-11-01

    Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

  6. Production and decay of chlorine ion excited species in an electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J P; Martins, M C; Parente, F [Centro de Fisica Atomica, CFA, Departamento de Fisica, Faculdade de Ciencias e Tecnologia, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Costa, A M; Marques, J P [Centro de Fisica Atomica, CFA, Departamento de Fisica, Faculdade de Ciencias, FCUL, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Indelicato, P, E-mail: jps@fct.unl.pt [Laboratoire Kastler Brossel, Ecole Normale Superieure, CNRS, Universite P et M Curie-Paris 6, Case 74, 4 place Jussieu, 75252 Paris Cedex 05 (France)

    2011-06-15

    The most important processes for the creation of chlorine ion excited states from the ground configurations of Cl{sup 10+} to Cl{sup 15+} ions in an electron cyclotron resonance ion source, leading to the emission of K x-ray lines, were studied. Theoretical values for inner-shell excitation and ionization cross-sections, including double KL and triple KLL ionization, transition probabilities and energies for the de-excitation processes, were calculated in the framework of the multi-configuration Dirac-Fock method. With reasonable assumptions about the electron energy distribution, a theoretical K{alpha} x-ray spectrum was obtained, which was then compared with recent experimental data.

  7. Comparison of cyclotron and linacs for high-intensity-beam applications

    Energy Technology Data Exchange (ETDEWEB)

    Bhatia, T.S.; Jason, A.; Mottershead, C.T. [Los Alamos National Lab., NM (United States); Cooper, R. [Amparo Corp., NM (United States)

    1998-11-01

    This is the final report of a two-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goals of this project were three-fold: (1) to understand the current level of cyclotron design expertise especially in the areas of space-charge modeling and simulation codes, (2) to develop a better understanding of the capabilities and limitations of circular machines, especially in the area of current limits, and (3) to stay abreast of the developments at other institutions in the area of high-current circular machines. These goals were partially met especially in the area of code development for the application of linac codes to motion of ions in a circular orbit. The authors were also able to continue their interactions with the other institutions working in this area.

  8. Development of Electron Cyclotron Resonance Ion Source for Synthesis of Endohedral Metallofullerenes

    Science.gov (United States)

    Tanaka, K.; Muramatsu, M.; Uchida, T.; Biri, S.; Asaji, T.; Shima, K.; Hanajiri, T.; Kitagawa, A.; Kato, Y.; Yoshida, Y.

    2008-11-01

    A new electron cyclotron resonance ion source (ECRIS) has been constructed for synthesis of endohedral metallofullerenes. The main purpose of the ion source is to produce new biological and medical materials. The design is based on ECRIS for production of multicharged ion beams with a traditional minimum-B magnetic field. An 8-10 GHz traveling wave tube (TWT) amplifier and a 2.45 GHz magnetron have been applied as microwave sources. Fullerene and metal vapor are introduced with a filament heating micro-oven and an induction heating oven, respectively. In preliminary ion-extraction test, Ar+ is 54 μA. Many broken fullerenes such as C58 and C56 are observed in fullerene ion beams.

  9. Compact commercial 9 MeV Deuteron cyclotron with pulsed beam

    Science.gov (United States)

    Erdman, K.; Johnson, D.; Papash, A.; Dehnel, M.; Gyles, B.; Kovac, B.; Medianu, S.; Popa, I.; Sabaiduc, V.; Watt, R.

    2001-12-01

    A Compact commercial Cyclotron to accelerate negative Deutron ionsup to an energy of 9 MeV was built by EBCO Technologies Inc. The Injection line, Central region and Inflector have been designed to accept beam of 15 keV/A injection energy. A short pulse Buncher was provided to ensure acceleration of single beam bursts. Extensive computer simulations of beam injection and beam acceleration were made to find possible solutions for single turn extraction of high intensity beam. Special attention was paid to center accelerated beam to better than 0.8 mm, to minimize dispersion and to keep the radial emittance to less than 0.5 PI mm*mrad.

  10. Time evolution of bremsstrahlung and ion production of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie [Los Alamos National Laboratory; Ropponen, Tommi [UNIV OF JYVASKYLA; Jones, Peter [UNIV OF JYVASKYLA; Peura, Pauli [UNIV OF JYVASKYLA

    2008-01-01

    Bremsstrahlung radiation measurement is one of the most commonly used plasma diagnostics methods. Most of the bremsstrahlung measurements with electron cyclotron resonance (ECR) ion sources have been performed in continuous operation mode yielding information only on the steady state bremsstrahlung emission. This article describes the results of bremsstrahlung and ion current measurement with the JYFL 14 GHz ECRIS operated in pulsed mode. The experiments reveal information about the bremsstrahlung radiation in plasma conditions before reaching the equilibrium. The time scale of bremsstrahlung production is compared to ion production time scale for different charge states. The bremsstrahlung data is presented with 2 millisecond time intervals as a function of neutral gas pressure and microwave power. Data from hundreds of microwave pulses is combined in order to have a sufficient amount of events at each time step. The relevant plasma physics phenomena during both, the leading and the trailing edge of the RF pulse, are discussed.

  11. Cyclotron-resonance-induced photovoltaic effect in high-mobility graphene in the quantum Hall regime

    Science.gov (United States)

    Masubuchi, Satoru; Onuki, Masahiro; Arai, Miho; Watanabe, Kenji; Taniguchi, Takashi; Machida, Tomoki

    2013-03-01

    We have investigated the infrared photoinduced voltage ΔV in high-mobility graphene on hexagonal boron nitride in the quantum Hall regime. We observed ΔV of up to several μV at ν = +/- 2 quantum Hall states under the cyclotron resonance conditions. The dependence of ΔV on the bias current indicates that ΔV signals derive from the photovoltaic effect rather than the bolometric effect. The dependence of ΔV on magnetic field direction and measurement geometry suggest the edge channel transport as an origin of photovoltaic effect. ΔV signals were robust up to T = 180 K, indicating that ΔV signals can be used for developing novel terahertz photodetectors operating at high temperatures.

  12. Study on the electron-cyclotron-emission diagnostics on JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Cheol Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-09-01

    Diagnostic system for electron cyclotron emission(ECE) in JT-60 have been surveyed. At JT-60 there are three different ECE-systems: a Fourier transformed spectroscopy system(FTS), a grating polycromater system(GPS), and a heterodyne radiometer system(HRS). Each of the systems has been examined to understand the instrumental feature with much attention to the sensitivity and the resolution. FTS has been studied with particular interest because of its continuous and wide spectral coverage and reliable characteristics for calibration. Some topics in instrumentation for FTS are discussed to get an insight on the system specifications optimal for tokamak experiments. Finally, experimental results of FTS with black body radiation at liquid-nitrogen temperature are described in connection with the calibration of the light guiding system for ECE from JT-60 plasma. 14 refs. (Author).

  13. The preliminary tests of the superconducting electron cyclotron resonance ion source DECRIS-SC2.

    Science.gov (United States)

    Efremov, A; Bekhterev, V; Bogomolov, S; Drobin, V; Loginov, V; Lebedev, A; Yazvitsky, N; Yakovlev, B

    2012-02-01

    A new compact version of the "liquid He-free" superconducting ECR ion source, to be used as an injector of highly charged heavy ions for the MC-400 cyclotron, is designed and built at the Flerov Laboratory of Nuclear Reactions in collaboration with the Laboratory of High Energy Physics of JINR. The axial magnetic field of the source is created by the superconducting magnet and the NdFeB hexapole is used for the radial plasma confinement. The microwave frequency of 14 GHz is used for ECR plasma heating. During the first tests, the source shows a good enough performance for the production of medium charge state ions. In this paper, we will present the design parameters and the preliminary results with gaseous ions.

  14. Fast wave current drive at high ion cyclotron harmonics on DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Petty, C.C.; Grassie, J.S. de; Pinsker, R.I.; Prater, R. [General Atomics, San Diego, CA (United States); Baity, F.W. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Mau, T.K. [University of California, San Diego, La Jolla, CA (United States); Porkolab, M. [Massachusetts Institute of Technology, Cambridge, MA (United States)

    2001-12-01

    Current driven by the fast Alfven wave is measured at the fourth and eighth harmonics of the deuterium ion cyclotron frequency in identical plasmas on the DIII-D tokamak. In non-sawtoothing discharges with neutral beam injection heating, the radial profile of the fast wave current drive (FWCD) is determined by the response of the loop voltage profile to co- and counter-antenna phasings. The dimensionless current drive efficiency is a factor of two greater for the eighth harmonic case compared to the fourth harmonic case. Modelling of the fast wave absorption using a ray tracing code shows that the decrease in FWCD efficiency for the latter situation can be explained by high harmonic damping of the fast waves on energetic ions. (author)

  15. Modeling of the influences of multiple modulated electron cyclotron current drive on NTMs in rotating plasma

    Science.gov (United States)

    Chen, Long; Liu, Jinyuan; Duan, Ping; Liu, Guangrui; Bian, Xingyu

    2017-02-01

    In this work, physical models of neoclassical tearing modes (NTMs) including bootstrap current and multiple modulated electron cyclotron current drive model are applied. Based on the specific physical problems during the suppression of NTMs by driven current, this work compares the efficiency of continuous and modulated driven currents, and simulates the physical processes of multiple modulated driven currents on suppressing rotating magnetic island. It is found that when island rotates along the poloidal direction, the suppression ability of continuous driven current can be massively reduced due to current deposition outside the island separatrix and reverse deposition direction at the X point, which can be avoided by current drive modulation. Multiple current drive has a better suppressing effect than single current drive. This work gives realistic numerical simulations by optimizing the model and parameters based on the experiments, which could provide references for successful suppression of NTMs in future advanced tokamak such as international thermonuclear experimental reactor.

  16. Electron cyclotron resonance ion source plasma characterization by energy dispersive x-ray imaging

    Science.gov (United States)

    Rácz, R.; Mascali, D.; Biri, S.; Caliri, C.; Castro, G.; Galatà, A.; Gammino, S.; Neri, L.; Pálinkás, J.; Romano, F. P.; Torrisi, G.

    2017-07-01

    Pinhole and CCD based quasi-optical x-ray imaging technique was applied to investigate the plasma of an electron cyclotron resonance ion source (ECRIS). Spectrally integrated and energy resolved images were taken from an axial perspective. The comparison of integrated images taken of argon plasma highlights the structural changes affected by some ECRIS setting parameters, like strength of the axial magnetic confinement, RF frequency and microwave power. Photon counting analysis gives precise intensity distribution of the x-ray emitted by the argon plasma and by the plasma chamber walls. This advanced technique points out that the spatial positions of the electron losses are strongly determined by the kinetic energy of the electrons themselves to be lost and also shows evidences how strongly the plasma distribution is affected by slight changes in the RF frequency.

  17. Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak.

    Science.gov (United States)

    Kim, J B; Lee, W; Yun, G S; Park, H K; Domier, C W; Luhmann, N C

    2010-10-01

    A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment.

  18. New compact and efficient local oscillator optic system for the KSTAR electron cyclotron emission imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Y. B., E-mail: southub@postech.ac.kr; Yun, G. S. [Department of Physics, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Lee, D. J.; Lee, J.; Lee, W. [Ulsan National Institute of Science and Technology, Ulsan 44919 (Korea, Republic of); Kim, C. [Pennsylvania State University, Old Main, State College, Pennsylvania 16801 (United States); Park, H. K. [Ulsan National Institute of Science and Technology, Ulsan 44919 (Korea, Republic of); National Fusion Research Institute, Daejeon 34133 (Korea, Republic of)

    2016-11-15

    Electron cyclotron emission imaging (ECEI) diagnostic on Korean Superconducting Tokamak Advanced Research utilizes quasi-optical heterodyne-detection method to measure 2D (vertical and radial) T{sub e} fluctuations from two toroidally separated poloidal cross section of the plasma. A cylindrical lens local oscillator (LO) optics with optical path length (OPL) 2–2.5 m has been used in the current ECEI system to couple the LO source to the 24 vertically aligned array of ECE detectors. For efficient and compact LO optics employing the Powell lens is proposed so that the OPL of the LO source is significantly reduced from ∼2.0 m to 0.4 m with new optics. The coupling efficiency of the LO source is expected to be improved especially at the edge channels. Results from the optical simulation together with the laboratory test of the prototype optics will be discussed in this paper.

  19. Prospects for advanced electron cyclotron resonance and electron beam ion source charge breeding methods for EURISOL.

    Science.gov (United States)

    Delahaye, P; Galata, A; Angot, J; Ban, G; Celona, L; Choinski, J; Gmaj, P; Jakubowski, A; Jardin, P; Kalvas, T; Koivisto, H; Kolhinen, V; Lamy, T; Lunney, D; Maunoury, L; Porcellato, A M; Prete, G F; Steckiewicz, O; Sortais, P; Thuillier, T; Tarvainen, O; Traykov, E; Varenne, F; Wenander, F

    2012-02-01

    As the most ambitious concept of isotope separation on line (ISOL) facility, EURISOL aims at producing unprecedented intensities of post-accelerated radioactive isotopes. Charge breeding, which transforms the charge state of radioactive beams from 1+ to an n+ charge state prior to post-acceleration, is a key technology which has to overcome the following challenges: high charge states for high energies, efficiency, rapidity and purity. On the roadmap to EURISOL, a dedicated R&D is being undertaken to push forward the frontiers of the present state-of-the-art techniques which use either electron cyclotron resonance or electron beam ion sources. We describe here the guidelines of this R&D.

  20. Innovations in optical coupling of the KSTAR electron cyclotron emission imaging diagnostic.

    Science.gov (United States)

    Liang, T; Tobias, B; Kong, X; Domier, C W; Luhmann, N C; Lee, W; Yun, G S; Park, H K

    2010-10-01

    The installation of a new electron cyclotron emission imaging diagnostic for the Korea Superconducting Tokamak Advanced Research (KSTAR) is underway, making use of a unique optical port cassette design, which allows placement of refractive elements inside the cryostat region without adverse effects. The result is unprecedented window access for the implementation of a state of the art imaging diagnostic. A dual-array optical design has been developed, capable of simultaneously imaging the high and low field sides of the plasma with independent features of focal plane translation, vertical zoom, and radial channel spacing. The number of translating optics has been minimized by making use of a zoom lens triplet and parabolic plasma facing lens for maximum channel uniformity over a continuous vertical zoom range of 3:1. The simulated performance of this design is presented along with preliminary laboratory characterization data.

  1. A study on the irradiation effect of reactor materials using a cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Joon Hwa; Ji, Se Hwan; Kang, Yung Hwan; Park, Duk Keun; Park, Jong Man; Lee, Bong Sang; Oh, Jong Myung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-12-01

    The objectives of the present study are to develop the simulation techniques of neutron irradiation through ion irradiation using a Cyclotron and small specimen techniques and to evaluate radiation effects of reactor materials. Effects of proton or neutron irradiation on domestic 12Cr-1MoV and SA508-3 steels were evaluated by small scale specimen test techniques, i.e, small punch and miniaturized tensile test. In order to study the radiation damage mechanism, irradiation effects of the steels were investigated by means of property change tests such as microstructure, physical and thermal properties. Feasibility study on application of a magnetic non-destructive methods to evaluate radiation effects on RPV materials was performed. 109 figs, 12 tabs, 102 refs. (Author).

  2. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Kuechler, D.; Toivanen, V. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2016-02-15

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  3. Design of a correlation electron cyclotron emission diagnostic for Alcator C-Moda)

    Science.gov (United States)

    Sung, C.; White, A. E.; Irby, J. H.; Leccacorvi, R.; Vieira, R.; Oi, C. Y.; Peebles, W. A.; Nguyen, X.

    2012-10-01

    A correlation electron cyclotron emission (CECE) diagnostic has been installed in Alcator C-Mod. In order to measure electron temperature fluctuations, this diagnostic uses a spectral decorrelation technique. Constraints obtained with nonlinear gyrokinetic simulations guided the design of the optical system and receiver. The CECE diagnostic is designed to measure temperature fluctuations which have kθ ≤ 4.8 cm-1 (kθρs < 0.5) using a well-focused beam pattern. Because the CECE diagnostic is a dedicated turbulence diagnostic, the optical system is also flexible, which allows for various collimating lenses and antenna to be used. The system overview and the demonstration of its operability as designed are presented in this paper.

  4. Ion hole formation and nonlinear generation of electromagnetic ion cyclotron waves: THEMIS observations

    Science.gov (United States)

    Shoji, Masafumi; Miyoshi, Yoshizumi; Katoh, Yuto; Keika, Kunihiro; Angelopoulos, Vassilis; Kasahara, Satoshi; Asamura, Kazushi; Nakamura, Satoko; Omura, Yoshiharu

    2017-09-01

    Electromagnetic plasma waves are thought to be responsible for energy exchange between charged particles in space plasmas. Such an energy exchange process is evidenced by phase space holes identified in the ion distribution function and measurements of the dot product of the plasma wave electric field and the ion velocity. We develop a method to identify ion hole formation, taking into consideration the phase differences between the gyromotion of ions and the electromagnetic ion cyclotron (EMIC) waves. Using this method, we identify ion holes in the distribution function and the resulting nonlinear EMIC wave evolution from Time History of Events and Macroscale Interactions during Substorms (THEMIS) observations. These ion holes are key to wave growth and frequency drift by the ion currents through nonlinear wave-particle interactions, which are identified by a computer simulation in this study.

  5. Investigations of proton beam energy of the MC-50 cyclotron at KIRAMS

    Science.gov (United States)

    Khandaker, Mayeen Uddin; Kim, Guinyun; Kim, Kwangsoo; Bin Abu Kassim, Hasan; Nikouravan, Bijan

    2011-07-01

    The accuracy of the measured excitation functions of nuclear reactions largely depend on the precise measurements of the exposed beam energy in activation experiment. We investigated the proton beam energy of the MC-50 cyclotron at the Korea Institute of Radiological and Medical Sciences (KIRAMS) employing the method natCu(p,xn)62Zn / natCu(p,xn)65Zn together with a stacked-foil activation technique. The beam energy along with the stacked samples was also theoretically calculated using computer program SRIM-2003. The measured beam energy showed generally a good agreement with the calculated ones, and this fact demonstrated that the energy (<30 MeV) of the proton beam could be determined by irradiating thin metallic Cu foil target with natural isotopic compositions. Hence, this may be considered as a useful technique for beam monitoring purposes in activation experiment.

  6. Cyclotron produced 198gAu, a potential radionuclide for diagnostic and therapeutic applications

    Science.gov (United States)

    Khandaker, Mayeen Uddin; Haba, Hiromitsu; Kassim, Hasan Abu

    2016-02-01

    Production cross-sections of the natPt(d,x)198Au reactions have been measured from a 24-MeV deuteron energy down to the threshold by using a stacked-foil activation technique combined with HPGe γ-ray spectrometry. Only a partial agreement is obtained with the existing literature data and the theoretical data extracted from the TENDL-2013 library. Physical thick target yield for the 198Au radionuclide was deduced using the measured cross-sections, and found a general agreement with the directly measured yield available in the literature. This study reveals that a low deuteron energy (<15 MeV) cyclotron and an enriched 198Pt (100%) target could be used to obtain 198Au in no carrier added form.

  7. Cyclotron produced 67Ga, a potential radionuclide for diagnostic and therapeutic applications

    Science.gov (United States)

    Khandaker, Mayeen Uddin; Haba, Hiromitsu; Kassim, Hasan Abu

    2015-04-01

    Production cross-sections of the natZn(d,x)67Ga reactions have been measured from a 24-MeV deuteron energy down to the threshold by using a stacked-foil activation technique combined with HPGe γ-ray spectrometry. An overall good agreement is found with some of the earlier measurements, whereas a partial agreement is obtained with the theoretical data extracted from the TENDL-2013 library. Physical thick target yield for the 67Ga radionuclide was deduced using the measured cross-sections, and found in agreement with the directly measured yield available in the literature. This study reveals that a low deuteron energy (<11 MeV) cyclotron and an enriched 66Zn target could be used to obtain 67Ga in no carrier added form.

  8. Specific features of reactor or cyclotron {alpha}-particles irradiated beryllium microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Khomutov, A.M. [A.A.Bochvar All-Russia Research Inst. of Inorganic Materials (VNIINM), Moscow (Russian Federation); Gromov, B.F.; Karabanov, V.N. [and others

    1998-01-01

    Studies were carried out into microstructure changes accompanying helium swelling of Be reactor neutron irradiated at 450degC or {alpha}-particles implanted in cyclotron to reach the same volume accumulation of He (6-8 ncm{sup 3} He/cm{sup 3} Be). The microstructures of reactor irradiated and implanted samples were compared after vacuum anneal at 600-800degC up to 50h. The irradiated samples revealed the etchability along the grain boundaries in zones formed by adequately large equilibrium helium pores. The width of the zones increased with the annealing time and after 50h reached 30{mu}. Depleted areas 2-3{mu} dia were observed in some regions of near grain boundary zones. The roles of grain boundaries and manufacturing pores as vacancies` sources and helium sinks are considered. (author)

  9. Trap density of GeNx/Ge interface fabricated by electron-cyclotron-resonance plasma nitridation

    Science.gov (United States)

    Fukuda, Yukio; Otani, Yohei; Toyota, Hiroshi; Ono, Toshiro

    2011-07-01

    We have investigated GeNx/Ge interface properties using Si3N4(7 nm)/GeNx(2 nm)/Ge metal-insulator-semiconductor structures fabricated by the plasma nitridation of Ge substrates using an electron-cyclotron-resonance-generated nitrogen plasma. The interface trap density (Dit) measured by the conductance method is found to be distributed symmetrically in the Ge band gap with a minimum Dit value lower than 3 × 1011 cm-2eV-1 near the midgap. This result may lead to the development of processes for the fabrication of p- and n-Ge Schottky-barrier (SB) source/drain metal-insulator-semiconductor field-effect transistors using chemically and thermally robust GeNx dielectrics as interlayers for SB source/drain contacts and high-κ gate dielectrics.

  10. Kinetic structure of slow shocks - Effects of the electromagnetic ion/ion cyclotron instability

    Science.gov (United States)

    Omidi, N.; Winske, D.

    1992-01-01

    The structure of slow magnetosonic shocks in the low beta regime is analyzed with attention given to ion heating and the effects of waves upstream of the electromagnetic ion/ion cyclotron (EMIIC) instability. Shock formation is assessed by means of three methods - a relaxation method and two based on dynamic flow interactions - to determine the effects of initialization and boundary conditions on the formation. Good solutions are found with the piston method and the similar flow-flow method in which the plasma is injected from two boundaries to form two slow shocks. Plasma parameters and shock normal angle are found to be the key variables dictating the structure of the magnetosonic shocks. Four unique classes of resultant shock structures are described in which classical, steady, or nonsteady behavior is found. The analysis also yields insight into the relationship between EMIIC instability and ion dissipation.

  11. Developing laser ablation in an electron cyclotron resonance ion source for actinide detection with AMS

    Energy Technology Data Exchange (ETDEWEB)

    Bauder, W. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Pardo, R.C.; Kondev, F.G.; Kondrashev, S.; Nair, C.; Nusair, O. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Palchan, T. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel); Scott, R.; Seweryniak, D.; Vondrasek, R. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Collon, P. [University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Paul, M. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel)

    2015-10-15

    A laser ablation material injection system has been developed at the ATLAS electron cyclotron resonance (ECR) ion source for use in accelerator mass spectrometry experiments. Beam production with laser ablation initially suffered from instabilities due to fluctuations in laser energy and cratering on the sample surface by the laser. However, these instabilities were rectified by applying feedback correction for the laser energy and rastering the laser across the sample surface. An initial experiment successfully produced and accelerated low intensity actinide beams with up to 1000 counts per second. With continued development, laser ablation shows promise as an alternative material injection scheme for ECR ion sources and may help substantially reduce cross talk in the source.

  12. Studies for the ion cyclotron range of frequency heating in a tokamak fusion experimental device

    Energy Technology Data Exchange (ETDEWEB)

    Saigusa, Mikio [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1996-02-01

    Ion cyclotron range of frequency heating has been investigated as an efficient additional plasma heating and non-inductive current driving methods in a tokamak type fusion experimental device. At first, an ICRF antenna coupling code was developed for the estimation of the coupling properties of phased antenna array, so that the ICRF antennas were designed for JT-60 and JT-60U ICRF heating systems using the coupling codes. The ICRF heating experiments had been performed in JT-60 and JT-60U. The coupling properties of ICRF antenna, the physics of peripheral plasma and energy confinement by ICRF heating in various heating regimes have been investigated. Next, the Toroidicity induced Alfven Eigen (TAE) mode have been studied using minority ICRF heating for producing energetic ions which can excite TAE mode. The TAE mode could be suppressed by current profile control using current ramp operation and lower hybrid current drive. (author) 74 refs.

  13. Progress in research, April 1, 1991--March 31, 1992, Texas A and M University Cyclotron Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-06-01

    Reports on research activities, facility operation, and facility development of the Texas A and M Cyclotron Institute for the period 1 April 1991--31 March 1992 are presented in this document. During the report period, the ECR-K500 Cyclotron Combination operated 4,377 hours. Of this time, 832 hours was used for beam development, 942 hours was used for tuning and optics, and the beam was available for experiments 2,603 hours. This time was used in a variety of studies including elastic and inelastic scattering, projectile break-up, the production and decay of giant resonances, fusion and fission dynamics, intermediate mass fragment emission, e{sup +}e{sup {minus}} production and molecular dissociation. In addition, studies of surfaces and metastable states in highly charged ions were carried out using the ECR source. Completion of two 19-element BaF{sub 2} arrays, of the focal plane detector for the proton spectrometer and installation of the HiLi multidetector have provided significant new experimental capabilities which have been further enhanced by major additions to the computer network. Progress on the Mass Achromat Recoil Spectrometer (MARS) is such that first operation of that device should occur this summer. Funding for installation of the MDM spectrometer was obtained at the beginning of this year. As this report is being completed, the Enge Split Pole Spectrometer is being disassembled and removed to make room for the MDM spectrometer. The split-pole will be shipped to CEBAF for use in experiments there. Installation of the MDM should be completed within the next year. Also expected in the next year is a 92 element plastic-CsI ball.

  14. (44g)Sc production using a water target on a 13MeV cyclotron.

    Science.gov (United States)

    Hoehr, Cornelia; Oehlke, Elisabeth; Benard, Francois; Lee, Chris Jaeil; Hou, Xinchi; Badesso, Brian; Ferguson, Simon; Miao, Qing; Yang, Hua; Buckley, Ken; Hanemaayer, Victoire; Zeisler, Stefan; Ruth, Thomas; Celler, Anna; Schaffer, Paul

    2014-01-01

    Access to promising radiometals as isotopes for novel molecular imaging agents requires that they are routinely available and inexpensive to obtain. Proximity to a cyclotron center outfitted with solid target hardware, or to an isotope generator for the metal of interest is necessary, both of which can introduce significant hurdles in development of less common isotopes. Herein, we describe the production of ⁴⁴Sc (t1/2=3.97 h, Eavg,β⁺=1.47MeV, branching ratio=94.27%) in a solution target and an automated loading system which allows a quick turn-around between different radiometallic isotopes and therefore greatly improves their availability for tracer development. Experimental yields are compared to theoretical calculations. Solutions containing a high concentration (1.44-1.55g/mL) of natural-abundance calcium nitrate tetrahydrate (Ca(NO₃)2·4 H₂O) were irradiated on a 13MeV proton-beam cyclotron using a standard liquid target. (44g)Sc was produced via the ⁴⁴Ca(p,n)(44g)Sc reaction. (44g)Sc was produced for the first time in a solution target with yields sufficient for early radiochemical studies. Saturation yields of up to 4.6 ± 0.3 MBq/μA were achieved using 7.6 ± 0.3 μA proton beams for 60.0 ± 0.2 minutes (number of runs n=3). Experimental data and calculation results are in fair agreement. Scandium was isolated from the target mixture via solid-phase extraction with 88 ± 6% (n=5) efficiency and successfully used for radiolabelling experiments. The demonstration of the production of ⁴⁴Sc in a liquid target greatly improves its availability for tracer development. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    H. W. Zhao

    2017-09-01

    Full Text Available The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24–28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of ^{40}Ar^{12+} and ^{129}Xe^{26+} have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL, China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24+18  GHz heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  16. Mechanical design control and implementation of a new movable diagnostic probe for the TRIUMF cyclotron

    Science.gov (United States)

    Ries, Thomas C.

    1994-10-01

    A new movable probe has been installed into the TRIUMF H- cyclotron. It is intended to measure the distribution of betatron amplitudes, in the vertical plane, of the circulating beam and to scrape halo. The probe, however, may also be scanned in the radial direction. The head may be positioned vertically and horizontally to an accuracy of 0.002`. The device is mechanically modular to facilitate fast and easy handling for maintenance in a radioactive area. The beam sensor on the probe head is a 1.25`×3`×0.003` tantalum foil and its overall coverage is 3.00`×7.25` in a vertical plane orthogonal to, and crossing through the beam orbit plane. Presently its radial center line location corresponds to a proton beam energy of about 430 MeV at radius 296`, however, the probe device may be easily relocated to operate from any 4` port, and, with an adaptor port flange, may be installed into any port in the cyclotron vacuum tank. A stationary catcher below the probe path collects those electrons stripped from the H- beam and scattered out from the probe head. The probe axis is vertical and the tank aperture is narrow so a worm gear arrangement combined with a modified ``Evans''-parallel linkage mechanism is used to transform vertical rotary motion into horizontal linear motion. The actuators are dc servo motors with tachometers driven by pulse width modulated servo amplifiers. Position sensing is done by variable reluctance type absolute rotary encoders and the higher level positioning is performed by TRIMAC based control software. The precision of movement and jitter was measured in the laboratory. Examples will be given of the probe use with beam.

  17. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  18. Ion cyclotron emission in tokamak plasmas; Emission cyclotronique ionique dans les plasmas de tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Fraboulet, D.

    1996-09-17

    Detection of {alpha}(3.5 MeV) fusion products will be of major importance for the achievement of self sustained discharges in fusion thermonuclear reactors. Due to their cyclotronic gyration in the confining magnetic field of a tokamak, {alpha} particles are suspected to radiate in the radio-frequency band [RF: 10-500 MHz]. Our aim is to determine whether detection of RF emission radiated from a reactor plasma can provide information concerning those fusion products. We observed experimentally that the RF emission radiated from fast ions situated in the core of the discharge is detectable with a probe located at the plasma edge. For that purpose, fast temporal acquisition of spectral power was achieved in a narrow frequency band. We also propose two complementary models for this emission. In the first one, we describe locally the energy transfer between the photon population and the plasma and we compute the radiation equilibrium taking place in the tokamak. {alpha} particles are not the unique species involved in the equilibrium and it is necessary to take into account all other species present in the plasma (Deuterium, Tritium, electrons,...). Our second model consists in the numerical resolution of the Maxwell-Vlasov with the use of a variational formulation, in which all polarizations are considered and the 4 first cyclotronic harmonics are included in a 1-D slab geometry. The development of this second model leads to the proposal for an experimental set up aiming to the feasibility demonstration of a routine diagnostic providing the central {alpha} density in a reactor. (author). 166 refs.

  19. External beam's nozzle design for the CRC cyclotron PIXE/PIGE

    Science.gov (United States)

    Choi, Yeon-Gyeong; Kim, Yu-Seok

    2015-02-01

    Recently, 13-MeV proton cyclotrons have been applied to non-destructive trace element analytical techniques, such as proton-induced X-ray emission (PIXE) and proton-induced gamma-ray emission (PIGE). A new extended beam line has been designed for PIXE/PIGE measurements in order to deliver protons to the target with minimal losses, thus reducing secondary radiation. A target chamber for PIXE/PIGE measurements is installed at the end of the extended beam line, and the beam size may be optimized by using a series of collimators that are located in front of the target. The optimized proton beam, with low currents (˜nA) for PIXE/PIGE experiments, requires a small beam size with variable energies from ˜10 keV to 3 MeV. Based on the ionization cross-section curve, a 3-MeV proton beam has been determined to be suitable for PIXE/PIGE measurements. Therefore, the 13-MeV protons extracted from the cyclotron must be reduced to 3 MeV, and this is achieved through the incorporation of an energy degrader. The appropriate thickness of the energy degrader has been estimated by using the stopping range in matter (SRIM) program. Also, suitable materials must be used for the construction of the collimator and the energy degrader in order to meet the requirements of low neutron activation due to the application of protons. In this study, we evaluated a number of suitable materials with low neutron yields and with little energy spread as the beam passes through the energy degrader and collimator. The appropriate thickness of the energy degrader for the reduction of the proton energy from 13 MeV to 3 MeV was determined using the SRIM code. Also, the neutron yield at the nozzle was estimated using the MCNPX code.

  20. Ion Bernstein instability as a possible source for oxygen ion cyclotron harmonic waves

    Science.gov (United States)

    Min, Kyungguk; Denton, Richard E.; Liu, Kaijun; Gary, S. Peter; Spence, Harlan E.

    2017-05-01

    This paper demonstrates that an ion Bernstein instability can be a possible source for recently reported electromagnetic waves with frequencies at or near the singly ionized oxygen ion cyclotron frequency, ΩO+, and its harmonics. The particle measurements during strong wave activity revealed a relatively high concentration of oxygen ions (˜15%) whose phase space density exhibits a local peak at energy ˜20 keV. Given that the electron plasma-to-cyclotron frequency ratio is ωpe/Ωe≳1, this energy corresponds to the particle speed v/vA≳0.3, where vA is the oxygen Alfvén speed. Using the observational key plasma parameters, a simplified ion velocity distribution is constructed, where the local peak in the oxygen ion velocity distribution is represented by an isotropic shell distribution. Kinetic linear dispersion theory then predicts unstable Bernstein modes at or near the harmonics of ΩO+ and at propagation quasi-perpendicular to the background magnetic field, B0. If the cold ions are mostly protons, these unstable modes are characterized by a low compressibility (|δB∥|2/|δB|2≲0.01), a small phase speed (vph˜0.2vA), a relatively small ratio of the electric field energy to the magnetic field energy (between 10-4 and 10-3), and the Poynting vector directed almost parallel to B0. These linear properties are overall in good agreement with the properties of the observed waves. We demonstrate that superposition of the predicted unstable Bernstein modes at quasi-perpendicular propagation can produce the observed polarization properties, including the minimum variance direction on average almost parallel to B0.