WorldWideScience

Sample records for caged ball prosthesis

  1. Bentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis

    OpenAIRE

    Sohns Christian; Wiese Christoph H; Friedrich Martin; Schotola Hanna; Coskun Kasim O; Popov Aron F; Ortmann Philipp; Schmitto Jan D; Mokashi Suyog A; Didilis Vassilios N; Schoendube Friedrich A

    2010-01-01

    Abstract We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic - no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial operation, we performed a Bentall-Procedure to treat an aortic ascendens aneurysm with di...

  2. Titanium ball joint total ossicular replacement prosthesis--experimental evaluation and midterm clinical results.

    Science.gov (United States)

    Gostian, A O; Pazen, D; Luers, J C; Huttenbrink, K B; Beutner, D

    2013-07-01

    During reconstruction of the ossicular chain, there is a need to address the forces and loads caused by the ambient atmospheric pressure variations and the resulting tympanic membrane movements. It is understood that when a rigid middle ear prosthesis is inserted the malleoincudal joint, a keyfactor in controlling pressure variations in the middle ear space is bypassed. In this paper we describe a modified total titanium ossicular replacement prosthesis with an innovative micro ball joint in the headplate which is designed to compensate for tympanic membrane movements caused by atmospheric pressure variations. The characteristics of this modified prosthesis were examined in temporal bone experiments and compared to the standard titanium total ossicular reconstruction prosthesis. Sound-induced stapes footplate movements were investigated by means of a Laser vibrometer and revealed no significant differences between the two prostheses in vitro. Intraoperatively, the insertion of the modified prosthesis required more delicate handling. The angle between the shaft and the headplate was variable and ranged from 60 to 90° as estimated by the surgeon. Twelve consecutive patients were eligible for clinical evaluation. The pure tone average (PTA) air-bone gap after a mean follow up period of 32 months was 18.8 dB. Furthermore, no extrusion, dislocation or other adverse events were observed. We conclude that the modified total ossicular replacement prosthesis with integrated micro ball joint yields similar volume velocities of the stapes footplate in the laboratory experiments compared to the standard rigid prosthesis. The audiological and morphological results are encouraging and show that the mobile prosthesis headplate adjusting to the level of the tympanic membrane is a further step in the development of a physiological middle ear implant. This article is part of a special issue entitled "MEMRO 2012". PMID:23142147

  3. Finite Element Analysis of Squirrel Cage Ball Bearingsfor Gas Turbine Engines

    Directory of Open Access Journals (Sweden)

    Benny George

    2007-03-01

    Full Text Available Squirrel cage ball bearings are used in recent aero engines to overcome the vibration andstability problems associated with rotor systems supported by conventional bearings. The criticaldesign feature of squirrel cage bearing is to provide flexible support to rotor system. The outerring of the bearing is configured such that it acts as a flexible bearing support, and hence, weightis minimised. The bearing is mounted directly on a rigid intermediate casing of a gas turbineengine. Finite element analysis helps to obtain a suitable geometry at the design stage. A 3-Dmodel of the bearing is created using IDEAS software. Finite element analysis using contactelement has been carried out for finding the deformation and stresses in the webs at variouslocations using ANSYS software. The deformations are compared with those of experimentalvalues for an axial load. The deformation in the webs is used to check the pressure balance inthe compressor and the load acting on the bearing. Finally, a procedure for doing the finiteelement analysis of ball bearings for combined axial and radial load is laid down.

  4. A Starr-Edwards mitral prosthesis after 44 years of good performance.

    Science.gov (United States)

    De Santo, Luca Salvatore; De Feo, Marisa; Della Corte, Alessandro; Cerasuolo, Flavio; Santé, Pasquale; Torella, Michele; Nappi, Gianantonio

    2010-06-01

    The Starr-Edwards caged-ball prosthesis has been widely used to replace cardiac valves. The Model 6120 mitral prosthesis was introduced on the market in 1965 to reduce the high incidence of ball variance and thromboembolism of the previous model. We report the case of a Starr-Edwards Model 6120 which had been in place for 44 years and was still well functioning with no apparent structural damage. PMID:20812436

  5. Prosthesis

    Science.gov (United States)

    ... by prosthetic devices. False teeth are known as dental prostheses. An artificial replacement of the jaw bone is called a maxillofacial prosthesis. Penis implants are also known as penile prostheses.

  6. Joint prosthesis and method of bone fixation

    NARCIS (Netherlands)

    Oosterom, R.; Van der Pijl, A.J; Bersee, H.E.N.; Van der Helm, F.C.; Herder, J.L

    2006-01-01

    The invention relates to a joint prosthesis (10), for example, a knee joint or shoulder joint prosthesis comprising a first, socket-holding prosthesis part (11) for attachment to a first bone (12) and a second, ball-holding prosthesis part (13) for attachment to a second bone (14) that intermates wi

  7. Joint prosthesis and method of bone fixation

    OpenAIRE

    Oosterom, R; Pijl, A J; Bersee, H.E.N.; Van der Helm, F.C.; Herder, J. L.

    2006-01-01

    The invention relates to a joint prosthesis (10), for example, a knee joint or shoulder joint prosthesis comprising a first, socket-holding prosthesis part (11) for attachment to a first bone (12) and a second, ball-holding prosthesis part (13) for attachment to a second bone (14) that intermates with the first prosthesis part, wherein the first bone and the second bone are situated at either side of a joint, and wherein the ball (2) of the second prosthesis part is rotatably received in the ...

  8. One-step direct synthesis of mesoporous aluminosilicates Al-SBA-15 with cage-like macropores by using micrometer-sized aluminum balls

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Ordered mesoporous aluminosilicate Al-SBA-15 materials with cage-like macropores have been synthesized by using micrometer-sized aluminum balls as an Al source,tetraethyl orthosilicate(TEOS) as a silica source,and triblock copolymer Pluronic P123 as a template.The resulting materials were fully characterized by XRD,N2 adsorption,SEM,TEM,ICP-AES,and 27Al MAS-NMR.The products(Al-SBA-15) have ordered two-dimensional(2-D) hexagonal mesostructures(space group p6mm).The calcined Al-SBA-15 materials exhibit disordered macropores with diameters of about 70―80 nm and ordered mesopores with a diameter of ~5 nm,a BET surface area of about 500 m2/g,Si/Al ratio of 40―80,and a ratio of tetrahedral Al to octahedral Al sites of about 2:1.This combination of properties gives these materials potential applications in areas such as adsorption,catalysis and separation.

  9. Flexible-body Dynamics Analysis on Cage of High-speed Angular Contact Ball Bearing%高速角接触球轴承保持架柔体动力学分析

    Institute of Scientific and Technical Information of China (English)

    邓四二; 谢鹏飞; 杨海生; 高银涛

    2011-01-01

    在角接触球轴承动力学分析基础上,结合轴承保持架的柔体性,采用修正的Craig-Bampton子结构模态综合法建立高速角接触球轴承保持架柔体动力学方程.利用ADAMS系统开发了角接触球轴承刚柔多体动力学分析程序,对高速角接触球轴承保持架动态性能进行了分析;并采用Gupta的角接触球轴承动力学分析结果加以验证.分析结果表明:角接触球轴承引导间隙与兜孔间隙之比、径向载荷与轴向载荷之比过大或过小都不利于保持架转动的平稳性;相对刚体保持架而言,柔体保持架转动更为平稳.%A dynamic analysis method for the flexible cage dynamic formula of high-speed angular contact ball bearing was described. The flexible cage dynamic formula of high-speed angular contact ball bearing computational formulation was established using a modified Craig-Bampton component mode synthesis method based on angular contact ball bearing dynamics analysis. The dynamic characteristics of cage of high-speed angular contact ball bearing was analyzed using rigid-flexible multi-body dynamic analysis program ADAMS, and was verified by the computation example of Gupta. The results show that the rotary smoothness of cage will be broken if the ratio of pocket clearance to guided clearance and the ratio of radial load to axial load become too large or too small. The flexible cage runs more smoothly compared to the rigid cage.

  10. Prosthesis coupling

    Science.gov (United States)

    Reswick, J. B.; Mooney, V.; Bright, C. W.; Owens, L. J. (Inventor)

    1979-01-01

    A coupling for use in an apparatus for connecting a prosthesis to the bone of a stump of an amputated limb is described which permits a bio-compatible carbon sleeve forming a part of the prosthesis connector to float so as to prevent disturbing the skin seal around the carbon sleeve. The coupling includes a flexible member interposed between a socket that is inserted within an intermedullary cavity of the bone and the sleeve. A lock pin is carried by the prosthesis and has a stem portion which is adapted to be coaxially disposed and slideably within the tubular female socket for securing the prosthesis to the stump. The skin around the percutaneous carbon sleeve is able to move as a result of the flexing coupling so as to reduce stresses caused by changes in the stump shape and/or movement between the bone and the flesh portion of the stump.

  11. Prosthesis Material

    Science.gov (United States)

    2004-01-01

    In this photograph, Amputee Amie Bradly uses a NASA-developed prosthesis to paint her fingernails. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  12. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  13. Holy balls!

    OpenAIRE

    Wright, Michael; Langley, Ken; Belden, Jesse; Truscott, Tadd

    2011-01-01

    We demonstrate the behavior of three balls skipping off of the water surface: a Superball, a racquetball, and a water bouncing ball (Waboba). The three balls have rebound coefficients of 0.9, 0.8 and 0.2, respectively. However, we notice that the Waboba bounces better than the others, but why? The Superball has a high coefficient of restitution, creating large rebounds. Here the impact is angled to the free surface, but the inelastic response and large mass ratio forces the ball underwater wi...

  14. Wispy Prosthesis: A Novel Method in Denture Weight Reduction

    Science.gov (United States)

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Peddinti, Vijaya Kumar

    2016-01-01

    Introduction Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. Aim To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Materials and Methods Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. Results It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. Conclusion This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis. PMID:27190947

  15. Holy balls!

    Science.gov (United States)

    Truscott, Tadd; Belden, Jesse

    2011-11-01

    Why can some balls walk on water while others cannot? We investigate the rebound dynamics of elastic spheres impacting on a free-surface. Several variables determine whether or not a sphere will bounce when impacting a free-surface including velocity, impact angle, size and elasticity. Stiff elastic spheres, such as a racquetball, successfully skip at low impact angles and high velocities, but tend not to bounce when the impact angle becomes too large. However, the more compliant Waboba (WAter BOuncing BAll) bounces marvelously even at very high impact angles. Unlike a stiffer ball, the Waboba flattens out quickly as it is forming a cavity. The cavity lip forms a ramp and the flattened ball then skips off the water surface. We demonstrate how this phenomenon surprisingly resembles a skipping stone. Using high-speed video we explore the rebound dynamics for various values of elasticity, velocity, angle and size and determine when an object will bounce off the water surface.

  16. plasma ball

    CERN Multimedia

    When you touch the ball, by earthing the surface, you increase the voltage difference between it and the centre. So more electrons flow through the gas at that point, creating the filaments of light you see.

  17. Golf Ball

    Science.gov (United States)

    1998-01-01

    The Ultra 500 Series golf balls, introduced in 1995 by Wilson Sporting Goods Company, has 500 dimples arranged in a pattern of 60 spherical triangles. The design employs NASA's aerodynamics technology analysis of air loads of the tank and Shuttle orbiter that was performed under the Space Shuttle External Tank program. According to Wilson, this technology provides 'the most symmetrical ball surface available, sustaining initial velocity longer and producing the most stable ball flight for unmatched accuracy and distance.' The dimples are in three sizes, shapes and depths mathematically positioned for the best effect. The selection of dimples and their placement optimizes the interaction of opposing forces of lift and drag. Large dimples reduce air drag, enhance lift, and maintain spin for distance. Small dimples prevent excessive lift that destabilizes the ball flight and the medium size dimples blend the other two.

  18. Taper Hip Prosthesis

    Medline Plus

    Full Text Available Zimmer M/L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome to this "OR Live" Webcast presentation brought to ... approximately one centimeter to the shoulder of my prosthesis. And then I will simply use the prosthesis ...

  19. Holy balls!

    CERN Document Server

    Wright, Michael; Belden, Jesse; Truscott, Tadd

    2011-01-01

    We demonstrate the behavior of three balls skipping off of the water surface: a Superball, a racquetball, and a water bouncing ball (Waboba). The three balls have rebound coefficients of 0.9, 0.8 and 0.2, respectively. However, we notice that the Waboba bounces better than the others, but why? The Superball has a high coefficient of restitution, creating large rebounds. Here the impact is angled to the free surface, but the inelastic response and large mass ratio forces the ball underwater without skipping. The racquetball has a lower mass ratio and a more elastic response to impacts. Also thrown at a shallow angle, it bounces off of the surface of the water 1-3 times before coming to rest. The Waboba flattens inside the cavity allowing it to skip off of the surface more easily. The flattened ball looks more like a skipping stone than a sphere due to its large elastic deformation at impact. Examining the reaction of a skipping stone we see that the stone creates a cavity in which it planes, slipping out of it...

  20. When to Replace a Prosthesis

    Science.gov (United States)

    ... to Replace a Prosthesis When to Replace a Prosthesis Web Development April 21, 2015 Fact Sheet Last ... workplace, they must be accurately fit with a prosthesis that matches their own anatomy; one that is ...

  1. Science of Ball Lightning (Fire Ball)

    Science.gov (United States)

    Ohtsuki, Yoshi-Hiko

    1989-08-01

    The Table of Contents for the full book PDF is as follows: * Organizing Committee * Preface * Ball Lightning -- The Continuing Challenge * Hungarian Ball Lightning Observations in 1987 * Nature of Ball Lightning in Japan * Phenomenological and Psychological Analysis of 150 Austrian Ball Lightning Reports * Physical Problems and Physical Properties of Ball Lightning * Statistical Analysis of the Ball Lightning Properties * A Fluid-Dynamical Model for Ball Lightning and Bead Lightning * The Lifetime of Hill's Vortex * Electrical and Radiative Properties of Ball Lightning * The Candle Flame as a Model of Ball Lightning * A Model for Ball Lightning * The High-Temperature Physico-Chemical Processes in the Lightning Storm Atmosphere (A Physico-Chemical Model of Ball Lightning) * New Approach to Ball Lightning * A Calculation of Electric Field of Ball Lightning * The Physical Explanation to the UFO over Xinjiang, Northern West China * Electric Reconnection, Critical Ionization Velocity, Ponderomotive Force, and Their Applications to Triggered and Ball Lightning * The PLASMAK™ Configuration and Ball Lightning * Experimental Research on Ball Lightning * Performance of High-Voltage Test Facility Designed for Investigation of Ball Lightning * List of Participants

  2. An improved nipple prosthesis.

    OpenAIRE

    Sainsbury, R.; Walker, V. A.; Smith, P M

    1991-01-01

    A nipple-areola reconstruction of prosthesis completes the process of breast reconstruction. Reconstructions are technically difficult and have poor long-term results, whereas commercial nipple prostheses are unsatisfactory in matching the normal colour and shape. We describe a simple technique for the manufacture of a custom made nipple-areola prosthesis.

  3. Stomatitis sub-prosthesis in patients with superior dental prosthesis

    OpenAIRE

    Antonia Martina Francisco Local; Yoel González Beriau; Ana Gloria Vázquez de León

    2009-01-01

    Background: The stomatitis sub-prosthesis is one of the most frequent changes in hard palate mucous membrane in patients with mucous-supported dental prosthesis. It can be caused by multiple factors, which makes its study and prognosis more difficult. Objective: To describe the occurrence of stomatitis sub-prosthesis and its causes in patients with superior dental prosthesis. Method: Descriptive study including all the patients with superior dental prosthesis examined in the odontology consul...

  4. Custom-made ocular prosthesis

    OpenAIRE

    Rajkumar Gunaseelaraj; Suma Karthikeyan; Kumar, Mohan N.; T Balamurugan; Jagadeeshwaran, A. R.

    2012-01-01

    An ocular defect may affect a patient psychologically. An ocular prosthesis is given to uplift the patient psychologically and improve the confidence. Ocular prosthesis can be custom made or a stock shell. To improve the comfort and matching of the prosthesis with that of the adjacent natural eye an custom made ocular prosthesis is preferred. Different techniques are available to fabricate a custom ocular prosthesis, here we have used paper iris disk technique.

  5. Four ball best ball 1.

    Science.gov (United States)

    Pollard, Geoff; Pollard, Graham

    2010-01-01

    In this paper a four-ball-best-ball (4BBB) model for pairs of golf players is set up. The 4BBB match-play scoring system is seen to satisfy a basic requirement of fairness. It is shown that it is not strictly possible to rate individual players as 4BBB players. However, a (reasonably broad) class of individual players is identified such that it is possible to rate them individually as 4BBB players. The capacity of an individual to play birdies is seen to be a very important determinant in being a successful member of a 4BBB pair, but there are other minor factors as well. Consideration is given to equal and unequal 4BBB pairs. The transitive law is seen to apply for 4BBB pairs. Thus, if pair A is better than pair B, and pair B is better than pair C, then pair A must be better than pair C. Correspondingly, if pair A is equal to pair B, and pair B is equal to pair C, then pair A is equal to pair C. Consideration is given to some strategic issues in 4BBB match-play golf. For example, the conditions under which a player should take a greater risk and have a higher probability of obtaining a bogie in order to achieve a higher probability of scoring a birdie, are determined. Also, the conditions under which a player, noting that his partner is about to have a 'bad' hole and score only a par or a bogie, should 'play safe', are determined. Thirdly, players who can interact in certain ways are seen to have an advantage over those pairs that cannot do this. Finally, one pair's optimal strategy when they see that their opponents are about to score a par or a bogie, but not a birdie, is analyzed. Key pointsA model for four-ball-best-ball match-play golf is established, and used to show that, although there can be other factors, the capacity of an individual to play birdies is a very important determinant in that player being a successful member of a four-ball-best-ball pair.Although it is not possible in general to rate play-ers individually as 4BBB players, a class of indi

  6. The Angelchik prosthesis

    International Nuclear Information System (INIS)

    The Angelchik prosthesis is used in the surgical treatment of gastroesophageal reflux. Operated patients are preliminary examined with imaging techniques, but manometric and acidometric techniques are also used. Although the conventional esophagogram still maintains its diagnostic significance, Computed Tomography (CT) has become the first-choice imaging modality. CT allows the correct evaluation of both the state of the prosthesis and its relationship to the esophagus and gastric fundus. The possible postoperative complications following an incorrect placement of the prosthesis can be accurately diagnosed too. The authors report their experience in the study of 5 patients examined with both conventional radiology and CT

  7. Taper Hip Prosthesis

    Medline Plus

    Full Text Available ... L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome ... hopefully you will see the benefits and the advantages of the new Zimmer Kinectiv System. Thank you. ...

  8. Taper Hip Prosthesis

    Medline Plus

    Full Text Available Zimmer M/L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome to this "OR Live" Webcast presentation brought to you by Zimmer. During ...

  9. FOUR BALL BEST BALL 1

    Directory of Open Access Journals (Sweden)

    Geoff Pollard

    2010-03-01

    Full Text Available In this paper a four-ball-best-ball (4BBB model for pairs of golf players is set up. The 4BBB match-play scoring system is seen to satisfy a basic requirement of fairness. It is shown that it is not strictly possible to rate individual players as 4BBB players. However, a (reasonably broad class of individual players is identified such that it is possible to rate them individually as 4BBB players. The capacity of an individual to play birdies is seen to be a very important determinant in being a successful member of a 4BBB pair, but there are other minor factors as well. Consideration is given to equal and unequal 4BBB pairs. The transitive law is seen to apply for 4BBB pairs. Thus, if pair A is better than pair B, and pair B is better than pair C, then pair A must be better than pair C. Correspondingly, if pair A is equal to pair B, and pair B is equal to pair C, then pair A is equal to pair C. Consideration is given to some strategic issues in 4BBB match-play golf. For example, the conditions under which a player should take a greater risk and have a higher probability of obtaining a bogie in order to achieve a higher probability of scoring a birdie, are determined. Also, the conditions under which a player, noting that his partner is about to have a ‘bad’ hole and score only a par or a bogie, should ‘play safe’, are determined. Thirdly, players who can interact in certain ways are seen to have an advantage over those pairs that cannot do this. Finally, one pair’s optimal strategy when they see that their opponents are about to score a par or a bogie, but not a birdie, is analyzed

  10. Measurement of separator contact forces in ball bearings using a derotation prism

    Science.gov (United States)

    Nypan, L. J.

    1978-01-01

    A derotation prism was used to produce a stationary image of balls deflecting a portion of the separator. Ball to cage contact forces in a 110 mm bearing at speeds to 12,000 rpm were found to be 25 N (five lb) maximum. Inner race land contact force was found to vary up to 20 N (four lb).

  11. [First clinical experiences with ceramic ball attachments for overdentures].

    Science.gov (United States)

    Büttel, Adrian E; Schmidli, Fredy; Marinello, Carlo P; Lüthy, Heinz

    2008-01-01

    In this prospective clinical study on 40 patients with similar clinical conditions (edentulous jaw with 2 interforaminal implants) commercially available ceramic ball attachments (ruby) were compared to commercial titanium ball attachments. The primary aim of the study was to measure the wear of the ball attachments after being 1 year in function. However, in the course of the study already after 7 to 12 months multiple failures with ceramic ball attachments occurred. Twelve (28%) of 43 ceramic ball attachments had to be replaced, mostly because of fractures (8) of the ceramic ball. It seems that ceramic ball attachments of the investigated design are not able to withstand normal intraoral stresses. The short-term susceptibility to fractures didn't allow to examine the ceramic-inherent features such as compressive strength and wear resistance. Furthermore, a secure connection between a titan base and a ceramic ball seems to be challenging. Based on these results, in implant-retained removable prosthesis the use of metal-based retainers is still recommended, although during maintenance a higher wear has to be expected. This wear can be compensated by either activating or changing the matrix or the patrix. PMID:18293602

  12. Stomatitis sub-prosthesis in patients with superior dental prosthesis

    Directory of Open Access Journals (Sweden)

    Antonia Martina Francisco Local

    2009-04-01

    Full Text Available Background: The stomatitis sub-prosthesis is one of the most frequent changes in hard palate mucous membrane in patients with mucous-supported dental prosthesis. It can be caused by multiple factors, which makes its study and prognosis more difficult. Objective: To describe the occurrence of stomatitis sub-prosthesis and its causes in patients with superior dental prosthesis. Method: Descriptive study including all the patients with superior dental prosthesis examined in the odontology consultation “Barrio Adentro” in the state of Miranda, Venezuela, from November, 2005 to March, 2006. The analysed variables were: age, sex, stomatitis level, teeth brushing frequency, prosthesis condition and use, palate mucous condition and frequency of odontology consultations. Results: 89 patients were attended, more 50% of them had superior dental prosthesis and presented stomatitis sub-prosthesis; the group between 35 and 59 years was the most affected, mainly females. Sub-prosthesis stomatitis type II was the most common and the main causes included constant use of the prosthesis and loose prosthesis. Buccal hygiene was not adequate in these patients. Most of them declared never attending to the dentist, or just when presenting some particular problem. Conclusion: Stomatitis prevalence was related with incorrect hygiene habits and lack of knowledge; it shows the importance of performing educative tasks to reduce this disease incidence.  

  13. Taper Hip Prosthesis

    Medline Plus

    Full Text Available Zimmer M/L Taper Hip Prosthesis with Modular Neck Kinectiv® Technology March 12, 2009 7:00 PM EDT Welcome to this "OR Live" Webcast presentation ... an "OR Live" Webcast on the Kinectiv Total Hip System. At this time, let’s join Dr. Maltry ...

  14. Having a Ball with Fitness Balls

    Science.gov (United States)

    McNulty, Betty

    2011-01-01

    Fitness programs can be greatly enhanced with the addition of fitness balls. They are a fun, challenging, economical, and safe way to incorporate a cardiovascular, strength, and stretching program for all fitness levels in a physical education setting. The use of these balls has become more popular during the last decade, and their benefits and…

  15. Ball Screw Actuator Including a Compliant Ball Screw Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2015-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  16. Q-ball metamorphosis

    International Nuclear Information System (INIS)

    Flat directions in the minimal supersymmetric standard model are known to deform into nontopological solitons, Q balls, which generally possess both baryon and lepton asymmetries. We investigate how Q balls evolve if some of the constituent fields of the flat direction decay into light species. It is found that the Q balls takes a new configuration whose energy per charge slightly increases due to the decay. Specifically, we show that all the stable Q balls eventually transform into pure B balls via the decay into neutrinos

  17. Q-ball Metamorphosis

    CERN Document Server

    Kawasaki, Masahiro; Kawasaki, Masahiro; Takahashi, Fuminobu

    2004-01-01

    Flat directions in the minimal supersymmetric standard model are known to deform into non-topological solitons, Q-balls, which generally possess both baryon and lepton asymmetries. We investigate how Q-balls evolve if some of the constituent fields of the flat direction decay into light species. It is found that the Q-balls takes a new configuration whose energy per charge slightly increases due to the decay. Specifically, we show that all the stable Q-balls eventually transform into pure B-balls via the decay into neutrinos.

  18. Biocompatibility of Nitinol Stapes Prosthesis

    OpenAIRE

    Röösli, C; P. Schmid; Huber, A. M.

    2011-01-01

    OBJECTIVE: Use of the SMart piston, a nitinol-based, self-crimping prosthesis in stapes surgery may allow improved functional results because of better sound transmission properties at the incus-prosthesis interface because of the elimination of manual crimping. Possible disadvantages include thermal damage or strangulation of the incus and its mucoperiosteum or nickel intolerance. The goal of this study was to morphologically assess the fixation of this prosthesis to the incus, investigate t...

  19. Doped golden fullerene cages

    OpenAIRE

    Baletto, Francesca; Ferrando, Riccardo

    2015-01-01

    A first-principles investigation of the effect of the doping of golden cages of 32 atoms is proposed. It is shown that Ag and Cu doping affects the geometrical stability of the icosahedral fullerene Au-32 cage, where Ag-doping leads to a new, low symmetric, and prolate motif while Cu-doping leads to a lump, incomplete decahedral shape. Most significantly, the HOMO-LUMO gap depends strongly on the cluster geometry while its dependence on the cluster chemical composition seems to be weaker.

  20. Evidence of hollow golden cages

    OpenAIRE

    Bulusu, Satya; Li, Xi; Wang, Lai-Sheng; Zeng, Xiao Cheng

    2006-01-01

    The fullerenes are the first “free-standing” elemental hollow cages identified by spectroscopy experiments and synthesized in the bulk. Here, we report experimental and theoretical evidence of hollow cages consisting of pure metal atoms, Aun− (n = 16–18); to our knowledge, free-standing metal hollow cages have not been previously detected in the laboratory. These hollow golden cages (“bucky gold”) have an average diameter >5.5 Å, which can easily accommodate one guest atom inside.

  1. John Cage Discusses Fluxus.

    Science.gov (United States)

    Snyder, Ellsworth

    1992-01-01

    Presents an informal discussion with composer John Cage which includes his response to George Maciunas' work, his recollections of Marcel Duchamp, the complex relationship between inelegant material and revealing works of art, neo-Dada and neo-Fluxus, Wittgenstein and the artist's ultimate responsibility to initiate a change in the viewer or…

  2. Actuated Ball Sports

    OpenAIRE

    Clerix, Ben

    2015-01-01

    Ball sports offer many physical, mental and social benefits, however they each require a different set of attributes, such as basketball hoops, volleyball nets, bowling pins, etc. Thus in order to play each of these ball sports, we need to provide and manually set up each of different attributes. Digital ball sports on the other hand virtualise these different attributes at the cost of losing physicality, however they have the possibility to create non-realistic experiences. Without physicali...

  3. Toric symplectic ball packing

    OpenAIRE

    Pelayo, Alvaro

    2007-01-01

    We define and solve the toric version of the symplectic ball packing problem, in the sense of listing all 2n-dimensional symplectic-toric manifolds which admit a perfect packing by balls embedded in a symplectic and torus equivariant fashion. In order to do this we first describe a problem in geometric-combinatorics which is equivalent to the toric symplectic ball packing problem. Then we solve this problem using arguments from Convex Geometry and Delzant theory. Applications to symplectic bl...

  4. The stump and the prosthesis.

    OpenAIRE

    Day, H. J.

    1980-01-01

    In performing amputations the surgeon must bear in mind the biomechanical and other constraints of the prosthesis likely to be fitted and, so far as possible, should fashion the stump accordingly. The various types of prosthesis and their features are discussed in relation to amputations of the lower and upper limbs at all levels.

  5. Physics of ball sports

    Science.gov (United States)

    Cohen, C.; Clanet, C.

    2016-06-01

    Ball sports have been part of human history for thousands of years [1]. Nowadays, 13 of them are part of the Olympic games (badminton, basketball, beach volley, football/soccer, golf, handball, hockey, rugby, table tennis, tennis, volleyball, water polo, ice hockey). All these games differ by launcher (hand, club, racket, bat), ball (size, shape and mass), pitch size and number of players. These differences induce different ball velocities. Apart from the velocities and the way to maximize them, we discuss in this article the ball trajectories and their impact on the size of sports fields.

  6. Large gauged Q balls

    Science.gov (United States)

    Anagnostopoulos, K. N.; Axenides, M.; Floratos, E. G.; Tetradis, N.

    2001-12-01

    We study Q balls associated with local U(1) symmetries. Such Q balls are expected to become unstable for large values of their charge because of the repulsion mediated by the gauge force. We consider the possibility that the repulsion is eliminated through the presence in the interior of the Q ball of fermions with charge opposite to that of the scalar condensate. Another possibility is that two scalar condensates of opposite charge form in the interior. We demonstrate that both these scenarios can lead to the existence of classically stable, large, gauged Q balls. We present numerical solutions, as well as an analytical treatment of the ``thin-wall'' limit.

  7. Design and Control of an Active Electrical Knee and Ankle Prosthesis

    OpenAIRE

    Sup, Frank; Varol, Huseyin Atakan; Mitchell, Jason; Withrow, Thomas; Goldfarb, Michael

    2008-01-01

    This paper presents an overview of the design and control of an electrically powered knee and ankle prosthesis. The prosthesis design incorporates two motor-driven ball screw units to drive the knee and ankle joints. A spring in parallel with the ankle motor unit is employed to decrease the power consumption and increase the torque output for a given motor size. The device’s sensor package includes a custom load cell to measure the sagittal socket interface moment above the knee joint, a cust...

  8. A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

    Science.gov (United States)

    Yang, Z.; Chen, H.; Yu, T.; Li, B.

    2016-08-01

    The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software tema Motion is used to track the spot which marked the cage surface. Finally, by developing the matlab program, a Lissajous' figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

  9. Borner Ball Neutron Detector

    Science.gov (United States)

    2002-01-01

    The Bonner Ball Neutron Detector measures neutron radiation. Neutrons are uncharged atomic particles that have the ability to penetrate living tissues, harming human beings in space. The Bonner Ball Neutron Detector is one of three radiation experiments during Expedition Two. The others are the Phantom Torso and Dosimetric Mapping.

  10. Ball screw inspection setup

    Science.gov (United States)

    Janusz, Rzepka; Sambor, Slawomir; Pienkowski, Janusz; Bielenin, Marcin

    2003-05-01

    In the following paper we describe arrangements of laser interferometer for investigation of screws and for inspection of ball screws. We have constructed two of them, namely: the technological setup for investigations of screw in process of production and the ball screw inspection setup. The former one is used to measure the pitch of screws. The data gathered during measurement is used to calculate the parameters for grinding machine. The later setup is used for testing parameters of complete ball screws. The software supporting this setup makes calculation of parameters of tested ball screw and creation of reports possible. Additionally, the inspection setup is the one that the torque measuring arrangements have been integrated on. Both the arrangements and the software allow for measurements of all parameters during movement of nut in full travel length of the ball screw and make charts and reports.

  11. Enhanced wear resistance of ball-and-socket joints of dental implants by means of titanium gaseous nitriding.

    Science.gov (United States)

    Gil, F J; Canedo, R; Padrós, A; Sada, E

    2002-07-01

    The aim of this research is the surface hardening of the ball-and-socket joint of dental implants by means of heat treatments in order to obtain titanium nitrides. These nitrides minimize the wear of the titanium used in prosthesis. In this paper the optimum heat treatment, the hardness and the wear resistance are described in relation to the ball-and-socket joint without heat treatment. PMID:12222756

  12. Happy Balls, Unhappy Balls, and Newton's Cradle

    Science.gov (United States)

    Kagan, David

    2010-01-01

    The intricacies of Newton's Cradle are well covered in the literature going as far back as the time of Newton! These discussions generally center on the highly elastic collisions of metal spheres. Thanks to the invention of happy and unhappy balls, you can build and study the interaction of less elastic systems (see Fig. 1).

  13. Compact Q-balls

    CERN Document Server

    Bazeia, D; Marques, M A; Menezes, R; da Rocha, R

    2016-01-01

    In this work we deal with non-topological solutions of the Q-ball type in two space-time dimensions, in models described by a single complex scalar field that engenders global symmetry. The main novelty is the presence of stable Q-balls solutions that live in a compact interval of the real line and appear from a family of models controlled by two distinct parameters. We find analytical solutions and study their charge and energy, and show how to control the parameters to make the Q-balls classically and quantum mechanically stable.

  14. Spinning Q-Balls

    OpenAIRE

    Volkov, Mikhail S.; Woehnert, Erik

    2002-01-01

    We present numerical evidence for the existence of spinning generalizations for non-topological Q-ball solitons in the theory of a complex scalar field with a non-renormalizable self-interaction. To the best of our knowledge, this provides the first explicit example of spinning solitons in 3+1 dimensional Minkowski space. In addition, we find an infinite discrete family of radial excitations of non-rotating Q-balls, and construct also spinning Q-balls in 2+1 dimensions.

  15. Rapid fabrication of a digital prosthesis.

    Science.gov (United States)

    Rokaya, Dinesh; Amornvit, Pokpong; Shrestha, Binit

    2015-12-01

    Finger prosthesis often needs refabrication due to its discoloration following use. This article presents a novel, economical, and cost-effective technique to duplicate the patient׳s existing prosthesis to obtain a new wax replica, which is then clinically tried and processed to obtain new silicone finger prosthesis. This technique requires comparatively less clinical and laboratory steps as to fabricate an entirely new prosthesis. The newly fabricated silicone finger prosthesis has the fit and marginal adaptation of the patient׳s existing prosthesis but the esthetics is improved. PMID:26684496

  16. Aerodynamics of sports balls

    Science.gov (United States)

    Mehta, R. D.

    Research data on the aerodynamic behavior of baseballs and cricket and golf balls are summarized. Cricket balls and baseballs are roughly the same size and mass but have different stitch patterns. Both are thrown to follow paths that avoid a batter's swing, paths that can curve if aerodynamic forces on the balls' surfaces are asymmetric. Smoke tracer wind tunnel tests and pressure taps have revealed that the unbalanced side forces are induced by tripping the boundary layer on the seam side and producing turbulence. More particularly, the greater pressures are perpendicular to the seam plane and only appear when the balls travel at velocities high enough so that the roughness length matches the seam heigh. The side forces, once tripped, will increase with spin velocity up to a cut-off point. The enhanced lift coefficient is produced by the Magnus effect. The more complex stitching on a baseball permits greater variations in the flight path curve and, in the case of a knuckleball, the unsteady flow effects. For golf balls, the dimples trip the boundary layer and the high spin rate produces a lift coefficient maximum of 0.5, compared to a baseball's maximum of 0.3. Thus, a golf ball travels far enough for gravitational forces to become important.

  17. Building a better Faraday cage

    Science.gov (United States)

    MartinAlfven; Wright, David; skocpol; Rounce, Graham; Richfield, Jon; W, Nick; wheelsonfire

    2015-11-01

    In reply to the physicsworld.com news article “Are Faraday cages less effective than previously thought?” (15 September, http://ow.ly/SfklO), about a study that indicated, based on mathematical modelling, that conducting wire-mesh cages may not be as good at excluding electromagnetic radiation as is commonly assumed.

  18. Cage-based performance capture

    CERN Document Server

    Savoye, Yann

    2014-01-01

    Nowadays, highly-detailed animations of live-actor performances are increasingly easier to acquire and 3D Video has reached considerable attentions in visual media production. In this book, we address the problem of extracting or acquiring and then reusing non-rigid parametrization for video-based animations. At first sight, a crucial challenge is to reproduce plausible boneless deformations while preserving global and local captured properties of dynamic surfaces with a limited number of controllable, flexible and reusable parameters. To solve this challenge, we directly rely on a skin-detached dimension reduction thanks to the well-known cage-based paradigm. First, we achieve Scalable Inverse Cage-based Modeling by transposing the inverse kinematics paradigm on surfaces. Thus, we introduce a cage inversion process with user-specified screen-space constraints. Secondly, we convert non-rigid animated surfaces into a sequence of optimal cage parameters via Cage-based Animation Conversion. Building upon this re...

  19. Choosing a Breast Prosthesis: A Survivor's Perspective

    Science.gov (United States)

    ... Survivor’s Perspective Print to PDF Choosing a Breast Prosthesis: A Survivor’s Perspective Andrea Zinn June 16, 2015 · ... did you decide to wear a breast form/prosthesis rather than have a reconstruction? Andrea: After weighing ...

  20. Friction moment analysis of space gyroscope bearing with ribbon cage under ultra-low oscillatory motion

    Directory of Open Access Journals (Sweden)

    Jiang Shaona

    2014-10-01

    Full Text Available This paper presents the model of calculating the total friction moment of space gyroscope ball bearings which usually work under ultra-low oscillatory motion and are very sensitive to the friction moment. The aim is to know the proportion of the friction moment caused by each frictional source in the bearing’s total friction moment, which is helpful to optimize the bearing design to deduce the friction moment. In the model, the cage dynamic equations considering six degree-of-freedom and the balls dynamic equations considering two degree-of-freedom were solved. The good trends with different loads between the measured friction moments and computational results prove that the model under constant rate was validated. The computational results show that when the speed was set at 5 r/min, the bearing’s maximum total friction moment when oscillation occurred was obviously larger than that occurred at a constant rate. At the onset of each oscillatory motion, the proportion of the friction moment caused by cage in the bearing’s total friction moment was very high, and it increased with the increasing speed. The analyses of different cage thicknesses and different clearances between cage pocket and ball show that smaller thickness and clearance were preferred.

  1. Friction moment analysis of space gyroscope bearing with ribbon cage under ultra-low oscillatory motion

    Institute of Scientific and Technical Information of China (English)

    Jiang Shaona; Chen Xiaoyang; Gu Jiaming; Shen Xuejin

    2014-01-01

    This paper presents the model of calculating the total friction moment of space gyro-scope ball bearings which usually work under ultra-low oscillatory motion and are very sensitive to the friction moment. The aim is to know the proportion of the friction moment caused by each frictional source in the bearing’s total friction moment, which is helpful to optimize the bearing design to deduce the friction moment. In the model, the cage dynamic equations considering six degree-of-freedom and the balls dynamic equations considering two degree-of-freedom were solved. The good trends with different loads between the measured friction moments and computational results prove that the model under constant rate was validated. The computational results show that when the speed was set at 5 r/min, the bearing’s maximum total friction moment when oscillation occurred was obviously larger than that occurred at a constant rate. At the onset of each oscillatory motion, the proportion of the friction moment caused by cage in the bearing’s total friction moment was very high, and it increased with the increasing speed. The analyses of different cage thicknesses and different clearances between cage pocket and ball show that smaller thickness and clearance were preferred.

  2. [Central auditory prosthesis].

    Science.gov (United States)

    Lenarz, T; Lim, H; Joseph, G; Reuter, G; Lenarz, M

    2009-06-01

    Deaf patients with severe sensory hearing loss can benefit from a cochlear implant (CI), which stimulates the auditory nerve fibers. However, patients who do not have an intact auditory nerve cannot benefit from a CI. The majority of these patients are neurofibromatosis type 2 (NF2) patients who developed neural deafness due to growth or surgical removal of a bilateral acoustic neuroma. The only current solution is the auditory brainstem implant (ABI), which stimulates the surface of the cochlear nucleus in the brainstem. Although the ABI provides improvement in environmental awareness and lip-reading capabilities, only a few NF2 patients have achieved some limited open set speech perception. In the search for alternative procedures our research group in collaboration with Cochlear Ltd. (Australia) developed a human prototype auditory midbrain implant (AMI), which is designed to electrically stimulate the inferior colliculus (IC). The IC has the potential as a new target for an auditory prosthesis as it provides access to neural projections necessary for speech perception as well as a systematic map of spectral information. In this paper the present status of research and development in the field of central auditory prostheses is presented with respect to technology, surgical technique and hearing results as well as the background concepts of ABI and AMI. PMID:19517084

  3. Constructional model of internal oesophageal prosthesis

    OpenAIRE

    L.A. Dobrzański; A. Pusz; A. J. Nowak; M. Górniak

    2010-01-01

    Purpose: The aim of this work is to study of constructional model of internal prosthesis of oesophagus with determined functional features; the prosthesis will replace the upper part of the digestive system – the oesophagus.Design/methodology/approach: Constructional model of internal prosthesis of oesophagus was worked out in the basis of physiological build of oesophagus considering surgical techniques.Findings: Development of optimal constructional model of internal prosthesis of oesophagu...

  4. Followup of a Dog with an Intraocular Silicone Prosthesis Combined with an Extraocular Glass Prosthesis

    OpenAIRE

    Gwendolyna Romkes; Johanna Corinna Eule

    2012-01-01

    Because of unpredictable corneal changes, evisceration and implantation of a silicone prosthesis does not always lead to a satisfying cosmetic result. This paper describes the use of an intraocular silicone prosthesis in combination with an extraocular glass prosthesis and shows a followup of two and a half years in a nonexperimental study. An intraocular silicone prosthesis was implanted after evisceration of the left eye in a five-month-old Bernese mountain dog. A glass prosthesis was fitte...

  5. Tunguska Dark Matter Ball

    CERN Document Server

    Froggatt, C D

    2014-01-01

    It is suggested that the Tunguska event in June 1908 cm-large was due to a cm-large ball of a condensate of bound states of 6 top and 6 anti-top quarks containing highly compressed ordinary matter. Such balls are supposed to make up the dark matter as we earlier proposed. The expected rate of impact of this kind of dark matter ball with the earth seems to crudely match a time scale of 200 years between the impacts. The main explosion of the Tunguska event is explained in our picture as material coming out from deep within the earth, where it has been heated and compressed by the ball penetrating to a depth of several thousand km. Thus the effect has some similarity with volcanic activity as suggested by Kundt. We discuss the possible identification of kimberlite pipes with earlier Tunguska-like events. A discussion of how the dark matter balls may have formed in the early universe is also given.

  6. The bowling balls

    CERN Document Server

    CERN Bulletin

    2010-01-01

    10 November 1972: CERN’s Bent Stumpe places an order for 12 bowling balls for a total cost of 95 US dollars. Although not evident at first sight, he is buying the heart of some of the first tracking devices to be used in the SPS control room. Today, Bent Stumpe’s device would be called a desktop mouse…   The first order for 4 bowling balls later changed to 12 balls. The bowling balls became the heart of Bent Stumpe's mouse. Almost 40 years ago, the web, Wikipedia and Google did not exist and it was much more difficult to know whether other people in other parts of the world or even in the same laboratory were facing the same problems or developing the same tools. At that time, Bent Stumpe was an electronics engineer, newly recruited to work on developments for the SPS Central Control room. One of the things his supervisor asked him to build as soon as possible was a device to control a pointer on a screen, also called a tracker ball. The heart of the device was the...

  7. 21 CFR 878.3550 - Chin prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chin prosthesis. 878.3550 Section 878.3550 Food... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3550 Chin prosthesis. (a) Identification. A chin prosthesis is a silicone rubber solid device intended to be implanted to augment...

  8. 21 CFR 878.3680 - Nose prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nose prosthesis. 878.3680 Section 878.3680 Food... DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3680 Nose prosthesis. (a) Identification. A nose prosthesis is a silicone rubber solid device intended to be implanted to augment...

  9. 21 CFR 878.3610 - Esophageal prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal prosthesis. 878.3610 Section 878.3610...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3610 Esophageal prosthesis. (a) Identification. An esophageal prosthesis is a rigid, flexible, or expandable tubular device...

  10. 21 CFR 876.3750 - Testicular prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Testicular prosthesis. 876.3750 Section 876.3750...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Prosthetic Devices § 876.3750 Testicular prosthesis. (a) Identification. A testicular prosthesis is an implanted device that consists of a solid or gel-filled...

  11. 21 CFR 878.3590 - Ear prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear prosthesis. 878.3590 Section 878.3590 Food and... GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3590 Ear prosthesis. (a) Identification. An ear prosthesis is a silicone rubber solid device intended to be implanted to reconstruct the...

  12. 21 CFR 878.3720 - Tracheal prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheal prosthesis. 878.3720 Section 878.3720...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3720 Tracheal prosthesis. (a) Identification. The tracheal prosthesis is a rigid, flexible, or expandable tubular device made of a...

  13. Blueprints for dodecahedral DNA cages

    International Nuclear Information System (INIS)

    Cage structures engineered from nucleic acids are of interest in nanotechnology, for example as a means of drug delivery (Destito et al 2007). Until now, most experimentally realized DNA cages have crystallographic symmetry, such as the shape of a cube (Chen and Seeman 1991 Nature 350 631-3), a tetrahedron (Goodman et al 2005 Science 310 1661-5), an octahedron (Shih et al 2004 Nature 427 618-21) or a truncated octahedron (Zhang and Seeman 1994 J. Am. Chem. Soc. 116 1661-9). Two examples of cages with non-crystallographic symmetry, a dodecahedron and a buckyball, have been realized recently (He et al 2008 Nature 452 198-201). A characteristic feature of these realizations is the fact that the cages are built from a number of identical building blocks called tiles: 20 for the case of the dodecahedron, and 60 for the case of the buckyball. We derive here a blueprint for the organization of nucleic acid in a dodecahedral cage such that the final product has a minimal number of strands. In particular, we show that a dodecahedral cage can be realized in terms of only two circular DNA molecules. We focus on the dodecahedral cage, because the volume to surface ratio of such a cage is larger than that of its crystallographic counterparts given the same fixed radial distance of the polyhedral vertices from the centre of the structure, whilst still requiring a smaller complexity than the truncated icosahedron (buckyball). We therefore expect that the dodecahedral DNA cages discussed here may be of interest in further applications in nanotechnology

  14. Prosthesis infections after orthopedic joint replacement

    DEFF Research Database (Denmark)

    Song, Zhijun; Borgwardt, Lotte; Høiby, Niels;

    2013-01-01

    Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore......, important to understand the comprehensive interaction between the microbiological situation and the host immune responses that lead to prosthesis infections. Evidence indicates that prosthesis infections are actually biofilm-correlated infections that are highly resistant to antibiotic treatment and the...... microbiological and surgical measures. Recent progress in research into bacterial biofilm and possible future treatment options of prosthesis-related infections are discussed....

  15. Therapeutical attitudes in tooth supported overdentures with ball attachements. Case report

    OpenAIRE

    Țâncu, AM; Melescanu Imre, M; Preoteasa, CT; Preoteasa, E

    2014-01-01

    Tooth supported overdenture with ball attachments has a number of advantages in prosthetics, but presents some difficulties as well, which sometimes make impossible the use of these anchoring systems; these difficulties should be well known. In this regard we present a suggestive case. It is the case of a patient, aged 57, who came for treatment, suffering from subtotal maxillary and mandibular edentulism (present 11 and 21, respectively 33 and 43), previously having an overdenture prosthesis...

  16. Laboratory demonstration of ball lightning

    International Nuclear Information System (INIS)

    A common laboratory facility for creating glowing flying plasmoids akin to a natural ball lightning, allowing a number of experiments to be performed to investigate the main properties of ball lightning, is described. (methodological notes)

  17. Off-pump minimally invasive direct coronary artery bypass in patients with cosmetic prosthesis for pectus excavatum.

    Science.gov (United States)

    Massi, Francesco; Manca, Mario; Muretti, Mirko; Portoghese, Michele

    2016-08-01

    Pectus excavatum can be associated with coronary artery diseases that can become difficult to manage in urgent situations. We describe the use of an off-pump minimally invasive direct coronary artery bypass (MIDCAB) through the fourth intercostal space incision in a patient with pectus excavatum and acute coronary syndrome who previously underwent a cosmetic prosthesis implantation. The patient refused any surgical procedure that could compromise the integrity of his cosmetic prosthesis and a left mini-thoracotomy was a good option to avoid the removal of the prosthesis. The preservation of the integrity of the thoracic cage enhanced chest wall stability and pulmonary function and permitted avoidance of inadvertent cardiac structure iatrogenic injuries. MIDCAB was optimal for the exposure of the left internal thoracic artery and the left anterior descending artery. The deformity of the chest should not be considered as an absolute contraindication to off-pump MIDCAB when other surgical options are not viable, even in emergency situations. PMID:27170745

  18. Elektra prosthesis for trapeziometacarpal osteoarthritis

    DEFF Research Database (Denmark)

    Klahn, A; Nygaard, Mads; Gvozdenovic, R;

    2012-01-01

    We present a prospective follow-up of 39 Elektra prostheses in 37 patients (32 women and five men), with a mean age of 56.5 (range 46-71) years; 34 patients had osteoarthritis and three had rheumatoid arthritis. Patients were followed using clinical examination, including measurement of pain on a...... the key problem in treating trapeziometacarpal osteoarthritis using a total prosthesis....

  19. Nonlinear dynamic model for skidding behavior of angular contact ball bearings

    Science.gov (United States)

    Han, Qinkai; Chu, Fulei

    2015-10-01

    A three-dimensional nonlinear dynamic model is proposed to predict the skidding behavior of angular contact ball bearings under combined load condition. The centrifugal and gyroscopic effects induced by ball rotation and revolution, Hertz contact between the ball and inner/outer races, discontinuous contact between the ball and cage and elastohydrodynamic lubrication are considered in the model. Through comparisons with the tested results of the reference, the dynamic model is verified. Based upon these, variations of ball slipping speed with time and space are discussed for the bearing under combined load condition. It is shown that radial load leads to the fluctuations in the slipping velocity of the ball contacting with inner/outer races, especially for the ball in load-decreasing regions. Adding the radial load would significantly increase the amplitude and range of slipping velocity, indicating that the skidding becomes more serious. As the ball still withstands contact load in the load-decreasing region, large slipping velocity would increase the temperature of both bearing and lubricant oil, intensify the wear and then might shorten the bearing service life. Therefore, the radial load should be considered carefully in the design and monitoring of rotating machinery.

  20. Artificial neural networks for automatic modelling of the pectus excavatum corrective prosthesis

    Science.gov (United States)

    Rodrigues, Pedro L.; Moreira, António H. J.; Rodrigues, Nuno F.; Pinho, ACM; Fonseca, Jaime C.; Correia-Pinto, Jorge; Vilaça, João. L.

    2014-03-01

    Pectus excavatum is the most common deformity of the thorax and usually comprises Computed Tomography (CT) examination for pre-operative diagnosis. Aiming at the elimination of the high amounts of CT radiation exposure, this work presents a new methodology for the replacement of CT by a laser scanner (radiation-free) in the treatment of pectus excavatum using personally modeled prosthesis. The complete elimination of CT involves the determination of ribs external outline, at the maximum sternum depression point for prosthesis placement, based on chest wall skin surface information, acquired by a laser scanner. The developed solution resorts to artificial neural networks trained with data vectors from 165 patients. Scaled Conjugate Gradient, Levenberg-Marquardt, Resilient Back propagation and One Step Secant gradient learning algorithms were used. The training procedure was performed using the soft tissue thicknesses, determined using image processing techniques that automatically segment the skin and rib cage. The developed solution was then used to determine the ribs outline in data from 20 patient scanners. Tests revealed that ribs position can be estimated with an average error of about 6.82+/-5.7 mm for the left and right side of the patient. Such an error range is well below current prosthesis manual modeling (11.7+/-4.01 mm) even without CT imagiology, indicating a considerable step forward towards CT replacement by a 3D scanner for prosthesis personalization.

  1. Frictional performance of ball screw

    International Nuclear Information System (INIS)

    As feed screws, ball screws have become to be adopted in place of trapezoidal threads. The structure of ball screws is complex, but those are the indispensable component of NC machine tools and machining centers, and are frequently used for industrial robots. As the problems in the operation of ball screws, there are damage, life and the performance related to friction. As to the damage and life, though there is the problem of the load distribution on balls, the results of the research on rolling bearings are applied. The friction of ball screws consists of the friction of balls and a spiral groove, the friction of a ball and a ball, the friction in a ball-circulating mechanism and the viscous friction of lubricating oil. It was decided to synthetically examine the frictional performance of ball screws, such as driving torque, the variation of driving torque, efficiency, the formation of oil film and so on, under the working condition of wide range, using the screws with different accuracy and the nuts of various circuit number. The experimental setup and the processing of the experimental data, the driving performance of ball screws and so on are reported. (Kako, I.)

  2. Twenty-Two-Year Experience with Aortic Valve Replacement: Starr-Edwards Ball Valves versus Disc Valves

    OpenAIRE

    Pilegaard, Hans K.; Lund, Ole; Nielsen, Torsten T; Magnussen, Karin; Knudsen, Mary A; Albrechtsen, Ole K.

    1991-01-01

    From 1965 through 1986, 817 patients underwent aortic valve replacement at our institution. Six hundred forty-five patients received Starr-Edwards ball valves, including 286 Silastic ball valves (Models 1200/1260), 165 cloth-covered caged-ball prostheses (Models 2300/2310/2320), and 194 track-valve prostheses (Model 2400). In contrast, 172 patients received disc-valve prostheses, including 126 St. Jude Medical aortic bi-leaflet disc valves, 32 Lillehei-Kaster pivoting disc valves, and 14 Björ...

  3. Hearing results with clothespin ossiculoplasty: preliminary report on the Kraus Modified Schuring Ossicle-Cup Prosthesis (Clothespin Prosthesis).

    Science.gov (United States)

    Kraus, E M

    1993-07-01

    The clothespin partial ossicular replacement prosthesis (PORP) is designed to increase joint stability during incus replacement ossiculoplasty. Fundamental modifications have been made in the Schuring ossicle-cup, which include a forked well, increased well wall thickness and length, and a flexible tip disk added to the shaft. The forked well functions like a straight clothespin rather than an inverted cup. The forked well enables the clothespin prothesis to slide down over the stapes superstructure, between the facial nerve canal and the promontory, to form a stable, mortise-and-tenon prosthesis-stapedial joint. Joint stability is enhanced because the inferior tine of the forked well is able to lever against the inferior surface of the stapes superstructure, creating a counterforce to gravity. This is in contrast to the more unstable ball-and-socket joint created by most partial ossicular replacement prostheses when they articulate with the stapes capitulum. The addition of a flexible disk to the shaft tip produces a tight, stable union between the prosthesis and the ossicular cap by increasing resistance at the shaft-ossicle interface. Fluoroplastic composition maximizes intraoperative versatility and reliability while the ossicle cap minimizes extrusions. One-year hearing results for twelve chronic ear patients with mobile stapes undergoing clothespin ossiculoplasty during intact canal wall tympanomastoidectomy revealed postoperative air-bone gaps within 20 dB in 92% of cases. The mean postoperative air-bone gap was 8.9 dB, and the mean improvement in air-bone gap was 14.4 dB.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8336964

  4. Women's Satisfaction with Their Breast Prosthesis: What Determines a Quality Prosthesis?

    Science.gov (United States)

    Livingston, Patricia M.; White, Victoria M.; Roberts, Susan B.; Pritchard, Emma; Hayman, Jane; Gibbs, Anne; Hill, David J.

    2005-01-01

    The aim of this study is to determine what factors constitute a quality prosthesis and ascertain which factors affect prosthesis satisfaction. Sixty-four women who received full funding for their prosthesis and 38 women who received their hospital's usual funding were recruited. Women rated the information provided about breast prostheses very…

  5. Techniques for Evaluating the Fit of Removable and Fixed Prosthesis

    OpenAIRE

    K Kamalakanth Shenoy; Shetty, Mallika S.

    2011-01-01

    The importance of an accurately fitting fixed prosthesis or a removable prosthesis is essential for the success of the restoration. Ill-fitting prosthesis may cause mechanical failures of the prosthesis, implant systems, or biologic complications of the surrounding tissue. There are several causes related to improper seating of the prosthesis. Some of which can be corrected and the others need to be repeated. Hence the clinician must carefully evaluate the adaptation of the prosthesis using t...

  6. Dosimetry of a silicone breast prosthesis

    International Nuclear Information System (INIS)

    Dose measurements were conducted in a phantom which simulates breast tissue and in another phantom which simulates a breast containing a silicone prosthesis. No detectable difference was found when the irradiations were carried out with tangential beams of 60Co radiation. The degree of backscatter and absorption of radiation by the prosthesis and phantom were also similar. A slight decrease in dose of approximately 8% was found at the interface between the prosthesis and muscle-equivalent material

  7. Practical Artifact Cancellation for Myoelectric Prosthesis Control

    OpenAIRE

    Sæther, Marthe

    2008-01-01

    Prostheses are artificial body parts that can be used by amputees. Myoelectric prostheses are controlled by so-called surface electromyograms (sEMG) that are acquired on the skin surface of the residual limb. A well-known problem in myoelectric prostheses is motion artifacts, these artifacts cause unwanted behaviour of the prosthesis. The purpose of this study is to try to cancel the effect motion artifacts have on myoelectric prosthesis control, in order to avoid unsolicited prosthesis be...

  8. Stretch due to Penile Prosthesis Reservoir Migration

    OpenAIRE

    Baten, E.; Vandewalle, T.; van Renterghem, K.

    2016-01-01

    A 43-year old patient presented to the emergency department with stretch, due to impossible deflation of the penile prosthesis, 4 years after successful implant. A CT-scan showed migration of the reservoir to the left rectus abdominis muscle. Refilling of the reservoir was inhibited by muscular compression, causing stretch. Removal and replacement of the reservoir was performed, after which the prosthesis was well-functioning again. Migration of the penile prosthesis reservoir is extremely ra...

  9. Cementless isoelastic RM total hip prosthesis1

    OpenAIRE

    Bombelli, Renato; Mathys, Robert

    1982-01-01

    Some surgeons are beginning to doubt the reliability of bone cement in joint replacements. In 1967 Robert Mathys conceived the idea of an isoelastic prosthesis made of plastic, which would anchor into the bone without cement. He developed the idea by extensive tests in animals and, in 1973, the first human RM cementless hip prosthesis was inserted by E Morscher. In this paper the concept of the cementless isoelastic prosthesis is developed by Robery Mathys, and Professor Bombelli records his ...

  10. An evaluation of intra-cage ventilation in three animal caging systems.

    Science.gov (United States)

    Keller, L S; White, W J; Snider, M T; Lang, C M

    1989-05-01

    Although temperature and relative humidity have been quantitated and their effects on research data studied, few studies have measured the air turnover rates at cage level. We evaluated the air distribution and air turnover rates in unoccupied shoe-box mouse cages, filter-top covered cages and shoe-box mouse cages housed in a flexible film isolator by using discontinuous gas chromatography/mass spectrometry and smoke. Results showed that air turnover was most rapid in the unoccupied shoe-box mouse cage and slowest in the filter-top covered cage. Placing mice in the filter-top covered cage did not significantly improve the air turnover rate. Although filter-top covered cages reduce cage-to-cage transmission of disease, the poor airflow observed within these cages could lead to a buildup of gaseous pollutants that may adversely affect the animal's health. PMID:2724925

  11. Hip painful prosthesis: surgical view

    OpenAIRE

    SPINARELLI, ANTONIO; Patella, Vittorio; Conserva, Vito; Vicenti, Giovanni; Pesce, Vito; Patella, Silvio

    2011-01-01

    Painful hip prosthesis is the most feared immediate and remote complication of a primary implant and usually represents the failure of one or more therapeutic moments. In cases of aseptic implant failure, the causes invoked may be represented by an incorrect indication, the quality of materials, local and general condition of the patient and especially from a bad joint biomechanics. In cases of septic loosening, however, the cause of failure to be found in the location of pathogens within the...

  12. Contact dermatitis from a prosthesis.

    Science.gov (United States)

    Munoz, Carla A; Gaspari, Anthony; Goldner, Ronald

    2008-01-01

    Patients wearing a prosthesis face a wide variety of medical problems. Skin complications have long been recognized, but their prevalence is still unknown. The most frequently reported disorders are allergic contact dermatitis (ACD), acroangiodermatitis, epidermoid cysts, epidermal hyperplasia, follicular hyperkeratosis, verrucous hyperplasia, bullous diseases, hyperhidrosis, infections, malignancies, and ulcerations. Contact dermatitis represents one-third of the dermatoses in amputees wearing prostheses. All patients who are suspected of having ACD should be patch tested with standard allergen series as well as materials from the patient's own prosthesis, topical medicaments, moisturizers, and cosmetics. We report a patient with an ACD to mixed dialkyl thiourea present in the rubber parts of his below-the-knee prosthesis. Thiourea derivates are used as accelerators in the manufacture of chloroprene rubber and as fixatives in photography and photocopy paper. Allergy to thiourea is relatively uncommon; different studies have shown a prevalence of 0.7% up to 2.4% in patch-tested patients. Thiourea derivates are often the allergic sources in ACD involving high-grade rubber products made of neoprene such as diving suits, protective goggles, knee braces, and continuous positive airway pressure masks. They are also present in the rubber material of prostheses, as in the case of our patient. PMID:18413115

  13. Air flow patterns and noise analysis inside high speed angular contact ball bearings

    Institute of Scientific and Technical Information of China (English)

    翟强; 闫柯; 张优云; 朱永生; 王亚泰

    2015-01-01

    The vortex formed around the rolling ball and the high pressure region formed around the ball−raceway contact zone are the principle factors that barricades the lubricant entering the bearing cavity, and further causes improper lubrication. The investigation of the air phase flow inside the bearing cavity is essential for the optimization of the oil−air two-phase lubrication method. With the revolutionary reference frame describing the bearing motion, a highly precise air phase flow model inside the angular contact ball bearing cavity was build up. Comprehensive factors such as bearing revolution, ball rotation, and cage structure were considered to investigate the influences on the air phase flow and heat transfer efficiency. The aerodynamic noise was also analyzed. The result shows that the ball spinning leads to the pressure rise and uneven pressure distribution. The air phase velocity, pressure and cage heat transfer efficiency increase as the revolving speed increases. The operating noise is largely due to the impact of the high speed external flow on the bearing. When the center of the oil−air outlet fixes near the inner ring, the aerodynamic noise is reduced. The position near the inner ring on the bigger axial side is the ideal position to fix the lubricating device for the angular contact ball bearing.

  14. Cage culture of sea bass in Malaysia

    OpenAIRE

    1994-01-01

    The article discusses the cage culture practice of sea bass (Lates calcarifer) in Malaysia. Problems on feed and seed supply and overcrowding are also discussed. Despite these problems, seabass cage culture still continuously booms.

  15. BLEACHING NEPTUNE BALLS

    Directory of Open Access Journals (Sweden)

    BONET Maria Angeles

    2014-05-01

    Full Text Available Posidonia Oceanic is a seaweed from Mediterranean Sea and it is more concentrated at the Balerian SEA. This implies the Valencian Community also. It forms vaste underwater meadows in the sea and are part of the Mediterranean ecosystem. It is a sea-grass specie with fruits and flowers. Leaves are ribbon-like and they grow in winter and at the end of summer some of them are separated and arrive to some sea line. Fuit is separated and can floate, it is known as “the olive of the sea” mainly in Italy, or as the Neptune Balls. As it can be used in different fields, it is is being studied in order ro have the precitice tests. Some authors have reported the manufacturing of fully bio-based comites with a gluten matrix by hot-press molding. And it has been considered as an effective insulator for building industry or even though to determine the presence of mercure in the Mediterranean sea some years ago. As many applications can be designed from that fibers, it has been considered to be bleached in order to used them in fashionable products. Consequently, its original brown color is not the most suitable one and it should be bleached as many other cellulosic fibers. The aim of this paper is to bleache neptune balls however, the inner fibers were not accessible at all and it implied not to bleach the inner fibers in the neptune ball. Further studiesd will consider bleaching the individualized fibers.

  16. Hurwitz ball quotients

    OpenAIRE

    Stover, Matthew

    2013-01-01

    We consider the analogue of Hurwitz curves, smooth projective curves $C$ of genus $g \\ge 2$ that realize equality in the Hurwitz bound $|\\mathrm{Aut}(C)| \\le 84 (g - 1)$, to smooth compact quotients $S$ of the unit ball in $\\mathbb{C}^2$. When $S$ is arithmetic, we show that $|\\mathrm{Aut}(S)| \\le 288 e(S)$, where $e(S)$ is the (topological) Euler characteristic, and in the case of equality show that $S$ is a regular cover of a particular Deligne--Mostow orbifold. We conjecture that this ineq...

  17. DNA Cages with Icosahedral Symmetry in Bionanotechnology

    Science.gov (United States)

    Jonoska, Nataša; Taormina, Anne; Twarock, Reidun

    Blueprints for polyhedral cages with icosahedral symmetry made of circular DNA molecules are provided. The basic rule is that every edge of the cage is met twice in opposite directions by the DNA strand(s), and vertex junctions are realized by a set of admissible junction types. As nanocontainers for cargo storage and delivery, the icosidodecahedral cages are of special interest because they have the largest volume per surface ratio of all cages discussed here.

  18. A Mobile Phone Faraday Cage

    Science.gov (United States)

    French, M. M. J.

    2011-01-01

    A Faraday cage is an interesting physical phenomenon where an electromagnetic wave can be excluded from a volume of space by enclosure with an electrically conducting material. The practical application of this in the classroom is to block the signal to a mobile phone by enclosing it in a metal can. The background of the physics behind this is…

  19. Holy Balls!: Part Deux

    Science.gov (United States)

    Belden, Jesse; Jandron, Michael; Truscott, Tadd

    2012-11-01

    A Waboba® (WAter BOuncing BAll) demonstrates remarkable water skipping behavior, even at relatively large impact angles. The highly compliant nature of these elastic spheres results in significant deformation into a disk-like shape upon impact. The increased wetted area and force coefficient generates a large hydrodynamic force that more readily lifts the ball off the water surface. However, elasticity introduces some surprising phenomena, such as material waves that propagate on the sphere and interact with the water cavity. Depending upon impact conditions, material waves may propagate in various directions combining to create multiple modes of deformation and complicated fluid-structure interactions. Furthermore, the timescales of deformation and wave propagation depend on the material properties and impact conditions. In this talk, we will discuss skipping regimes in terms of impact parameters and material properties and relate failed skipping behavior to the structure-fluid interaction caused by deformation. The critical timescales for deformation, wave propagation and collision will be related to the relevant physical parameters of the problem.

  20. Provox voice prosthesis — The Indian experience

    OpenAIRE

    Nayak, Umanath K.

    2001-01-01

    Following Total Laryngectomy, Tracheo-oesophageal speech prosthesis offers the most reliable form of voice rehabilitation. Of the various prostheses currently available. The Provox voice prosthesis developed by the Netherlands Cancer Institute has been the most popular due to its superior design and in-dwelling nature.

  1. The design of a reflectionless arterial prosthesis

    OpenAIRE

    Kol, Guy Richard; Woafo, Paul

    2010-01-01

    We propose a new technique to characterize a reflectionless arterial prosthesis. The corresponding transmission and reflection coefficients are determined from the geometric and the elastic properties of the arterial wall, and the interaction between the latter and the prosthesis are studied accordingly.

  2. Brucella endocarditis on double valvular prosthesis.

    OpenAIRE

    Lezaun, R; Teruel, J.; Maître, M. J.; De Artaza, M

    1980-01-01

    The case is reported of a 48-year-old man suffering from Brucella endocarditis on a double prosthesis. The successful medical and surgical treatment is described. So far as the authors know, this is the first report of Brucella endocarditis from a heart valve prosthesis.

  3. Ball lightning: a realistic model

    International Nuclear Information System (INIS)

    Ball lightning is a rare and beautiful phenomenon, still lacking a scientific explanation. Here, the main ideas of a recent topological model are summarized. This model provides reasons for the stability of the ball and it is able to explain some curious contradictions in the reports of the witnesses. (Author) 3 refs

  4. Experimental research on ball lightning

    International Nuclear Information System (INIS)

    Experiments on producing ball lightning were made with discharge in flammable gas and/or aerosol. A long lifetime (2 s) ball lightning was observed in 2.7 % ethane and 100 cm3 cotton fibers, and in 1.5 % methane and 1.9 % ethane

  5. Eddy Current Model of Ball Lightning

    OpenAIRE

    Shelton, J. D.

    2011-01-01

    Eddy Current Model of Ball Lightning Calculations show that high-energy ball lightning may consist of a ball of plasma containing a large circular electric current arising as an eddy current generated by lightning. Synthetic ball lightning might serve as a method of plasma confinement for purposes of nuclear fusion. In this paper, three articles concerning ball lightning and the related phenomenon of large ball lightning are combined to provide insight into this rarely glimpsed occurrence.

  6. 21 CFR 878.3800 - External aesthetic restoration prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External aesthetic restoration prosthesis. 878... External aesthetic restoration prosthesis. (a) Identification. An external aesthetic restoration prosthesis... external prosthesis adhesive. The device is not intended to be implanted. (b) Classification. Class...

  7. Prediction of tar ball formation

    Energy Technology Data Exchange (ETDEWEB)

    Khelifa, A.; Gamble, L. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch

    2006-07-01

    The presence of small tar balls ranging in size from less than a millimetre to 60 centimetres have been observed during cleanup assessment operations following accidental oil spills on water. The tar balls are composed of heavy oil residues and suspended particulate matter (SPM) from the water column. They can be found on shorelines, settled on the seafloor and floating at or near the water surface. Their abundance on the shorelines varies from site to site and depends on the conditions of the spill and mixing conditions. Aggregation between SPM and micro-sized oil droplets occurs naturally in coastal waters and enhances the dispersion of spilled oil. Although tar balls are among the important end states of spilled oil in the marine environment, no model exists to estimate the percentage of the spilled oil that becomes tar balls. This paper offered some insight into the modeling of tar ball formation. Current modeling understanding of oil-SPM aggregate formation was used to predict tar ball formation. The formation of oil droplets was examined with respect to a range of conditions under which the formation of large droplets is expected. The role of aggregation was then presented to demonstrate the effects of concentration and type of SPM on the buoyancy of tar balls. Good agreement was found between modeling results and field data reported in the literature regarding the size and density of tar balls. Oil viscosity and mixing energy were found to be the main factors controlling the formation of tar balls. The aggregation of tar balls with SPM and shoreline material results in significant increases or decreases in density, depending on the type and concentration of SPM. 42 refs., 2 tabs., 6 figs.

  8. Charge-Swapping Q-balls

    CERN Document Server

    Copeland, Edmund J; Zhou, Shuang-Yong

    2014-01-01

    Q-balls are non-topological solitonic solutions to a wide class of field theories that possess global symmetries. Here we show that in these same theories there also exists a tower of novel composite Q-ball solutions where, within one composite Q-ball, positive and negative charges co-exist and swap at a frequency lower than the natural frequency of an individual Q-ball. These charge-swapping Q-balls are constructed by assembling Q-balls and anti-Q-balls tightly such that their nonlinear cores overlap. We explain why charge-swapping Q-balls can form and why they swap charges.

  9. Improvements in ball-point pens

    International Nuclear Information System (INIS)

    A method of treating the surface of balls for use in roller ball pens, comprising the operations of placing a plurality of the said balls in a container in an evacuated enclosure, subjecting the balls to bombardment with a beam of ions, and agitating the balls so that the balls are in a state of continuous motion while they are being subjected to ion bombardment. The beam current is passed through the mass of balls by arcing. The beam may be of N+ ions, to increase wear resistance of the surface of the balls which may be of tungsten carbide. (author)

  10. Electronic cages for living cells.

    Science.gov (United States)

    Al Saeed, Sarah; Bakewell, David J

    2015-08-01

    Design and construction of an electronic cage is described which enables real-time manipulation of live and dead eukaryotic cells. Non-uniform, radio frequency (RF) AC electric fields are used to enable translational and rotational movement of cells, known as dielectrophoresis (DEP) and electro-rotation (EROT), and distinguish their state as viable and non-viable. A concentric multilayered mathematical model, applicable for eukaryotic cells, is also developed, coded and implemented. The simulations predict three dielectric dispersions in the DEP and EROT spectra, though in practice the third is very small so that two are observed. The cage is part of a multi-staged project incorporating controller and DEP/EROT digital signal generator and image processing. PMID:26736401

  11. Patients with hip prosthesis: radiotherapy treatment planning considerations

    International Nuclear Information System (INIS)

    The number of patients with hip prosthesis undergoing radiotherapy for pelvic cancer worldwide is increasing. This might be of importance depending on the materials in the prosthesis and whether any of the treatment fields are involved in the prosthesis. Radiotherapy planning involving the pelvic region of patients having total hip prosthesis has been found to be difficult due to the effect of the prosthesis on the dose distribution. This review is intended to project dosimetric considerations and possible solutions to this uncommon problem

  12. Stemless shoulder prosthesis versus conventional anatomic shoulder prosthesis in patients with osteoarthritis

    OpenAIRE

    Berth, Alexander; Pap, Géza

    2012-01-01

    Background The stemless shoulder prosthesis is a new concept in shoulder arthroplasty. To date, only a few studies have investigated the results of this prosthesis. The aim of this study was to investigate the clinical and radiological midterm results of this implant in comparison with a standard anatomic stemmed shoulder prosthesis. Materials and methods The Constant score, the DASH score, the active range of motion (abduction, anteversion, external rotation), and the radiological results we...

  13. Functional Impression Technique for an Ocular Prosthesis

    OpenAIRE

    Jethwani, Jitendra; Jethwani, Gayathri S.; Verma, A. K.

    2011-01-01

    The loss of an eye is the most devastating, psychologically damaging experience for a patient. All hope to bring such patients back to their accustomed and comfortable life-style rests on a cosmetically acceptable prosthesis. An intra-orbital ocular prosthesis serves the purpose in those defects where the orbital margins are intact. Though the stock eye may match the natural eye’s iris and sclera in color, the fit of the prosthesis to the tissue bed may not be as good as desired. Herein, a fu...

  14. Polymers containing borane or carborane cage compounds and related applications

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, III, Daniel E; Eastwood, Eric A

    2013-04-23

    Polymers comprising residues of cage compound monomers having at least one polyalkoxy silyl substituent are provided. The cage compound monomers are selected from borane cage compound monomers comprising at least 7 cage atoms and/or carborane cage compound monomers comprising 7 to 11 cage compound monomers. Such polymers can further comprise one or more reactive matrices and/or co-monomers covalently bound with the cage compound monomer residues. Articles of manufacture comprising such polymers are also disclosed.

  15. Enhancing the Bounce of a Ball

    Science.gov (United States)

    Cross, Rod

    2010-01-01

    In sports such as baseball, softball, golf, and tennis, a common objective is to hit the ball as fast or as far as possible. Another common objective is to hit the ball so that it spins as fast as possible, since the trajectory of the ball through the air is strongly affected by ball spin. In an attempt to enhance both the coefficient of…

  16. Split-ball resonator

    CERN Document Server

    Kuznetsov, Arseniy I; Fu, Yuan Hsing; Viswanathan, Vignesh; Rahmani, Mohsen; Valuckas, Vytautas; Kivshar, Yuri; Pickard, Daniel S; Lukiyanchuk, Boris

    2014-01-01

    We introduce a new concept of split-ball resonator and demonstrate a strong omnidirectional magnetic dipole response for both gold and silver spherical plasmonic nanoparticles with nanometer-scale cuts. Tunability of the magnetic dipole resonance throughout the visible spectral range is demonstrated by a change of the depth and width of the nanoscale cut. We realize this novel concept experimentally by employing the laser-induced transfer method to produce near-perfect spheres and helium ion beam milling to make cuts with the nanometer resolution. Due to high quality of the spherical particle shape, governed by strong surface tension forces during the laser transfer process, and the clean, straight side walls of the cut made by helium ion milling, magnetic resonance is observed at 600 nm in gold and at 565 nm in silver nanoparticles. Structuring arbitrary features on the surface of ideal spherical resonators with nanoscale dimensions provides new ways of engineering hybrid resonant modes and ultra-high near-f...

  17. Ball-joint grounding ring

    Science.gov (United States)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  18. Studies On Falling Ball Viscometry

    OpenAIRE

    Singh, Amit Vikram; Sharma, Lavanjay; Gupta-Bhaya, Pinaki

    2012-01-01

    A new method of accurate calculation of the coefficient of viscosity of a test liquid from experimentally measured terminal velocity of a ball falling in the test liquid contained in a narrow tube is described. The calculation requires the value of a multiplicative correction factor to the apparent coefficient of viscosity calculated by substitution of terminal velocity of the falling ball in Stokes formula. This correction factor, the so-called viscosity ratio, a measure of deviation from St...

  19. Cleaning Animals' Cages With Little Water

    Science.gov (United States)

    Harman, Benjamin J.

    1989-01-01

    Proposed freeze/thaw method for cleaning animals' cages requires little extra weight and consumes little power and water. Cleaning concept developed for maintaining experimental rat cages on extended space missions. Adaptable as well to similar use on Earth. Reduces cleaning time. Makes use of already available facilities such as refrigerator, glove box, and autoclave. Rat waste adheres to steel-wire-mesh floor of cage. Feces removed by loosening action of freezing-and-thawing process, followed by blast of air.

  20. Penile prosthesis implantation in a transsexual neophallus

    Institute of Scientific and Technical Information of China (English)

    Hui-MengTAN

    2000-01-01

    Reconstruction surgery for a female to male transsexual usually involves mastectomy, hysterectomy and creating an aesthetically appealing neophallus. We have successfully inserted an inflatable prosthesis using the AMS CX prosthesis in a 45 year old transsexual, who had a large bulky neophallus constructed from the anterior abdominal subcutaneous fat, about 9 years ago. The single cylinder CX prosthesis was well anchored to the symphysis pubis using a dacron windsock tubing, the activation pump was placed in the dependent pouch of the right labium and the reservior in the usual perivesical space. The patient subsequently had debulking procedure using liposuction to create a more aesthetic and functional phallus. To date, the inflatable neophallus prosthesis is functioning well. (Asian J Androl 2000 Dec;2:304-306)

  1. LHC gets the ball rolling

    CERN Multimedia

    2007-01-01

    A technique involving a small ball with a transmitter embedded inside it has been successfully tested in Sector 7-8. The ball is sent through the LHC beam pipes to check the LHC interconnections. The multidisciplinary team responsible for the RF ball project to check the interconnections. From left to right: Rhodri Jones (AB/BI), Eva Calvo (AB/BI), Francesco Bertinelli (AT/MCS), Sonia Bartolome Jimenez (TS/IC), Sylvain Weisz (TS/IC), Paul Cruikshank (AT/VAC), Willemjan Maan (AT/VAC), Alain Poncet (AT/MCS), Marek Gasior (AB/BI). During the tests the ball is inserted very carefully into the vacuum chamber.A game of ping-pong at the LHC? On 13 September a rather unusual test was carried out in Sector 7-8 of the accelerator. A ball just a bit smaller than a ping-pong ball was carefully introduced into one of the accelerator’s two vacuum pipes, where it travelled 800 metres in the space of a few mi...

  2. Listening to Cage: Nonintentional philosophy and music

    Directory of Open Access Journals (Sweden)

    Richard Fleming

    2016-12-01

    Full Text Available Listening to Cage: Nonintentional Philosophy and Music threads together the writings of ordinary language philosophy and the music of John Cage, responding specifically to requests made by Cage and Stanley Cavell. While many texts downplay or ignore the philosophical demands in Cage’s music and other texts find grandiose spiritual and philosophical material tied to his work, this text rejects both efforts. It challenges the basic directions of the growing secondary source material on Cage, finding it largely contrary to what Cage himself and his music teaches. That secondary material constantly offers an intentional approach to the music which is to make Cage understandable or easier to understand. The present text makes him appropriately difficult and basically unapproachable, asking the reader for serious acknowledgment of what Cage says he does, namely, “I have nothing to say and I am saying it.” While there is little hope of stopping the Cage industry that academia and publishers have grown, this text wishes at least to try to slow it down. The footnotes of this text include direct conversation material with Cage from the 1980s and 1990s regarding many subjects—his own compositions, our life struggles, remarks on Wittgenstein, Thoreau, philosophy, and music—all with a new context for their hearing.

  3. Development of Receiver Stimulator for Auditory Prosthesis

    OpenAIRE

    K. Raja Kumar; P. Seetha Ramaiah

    2010-01-01

    The Auditory Prosthesis (AP) is an electronic device that can provide hearing sensations to people who are profoundly deaf by stimulating the auditory nerve via an array of electrodes with an electric current allowing them to understand the speech. The AP system consists of two hardware functional units such as Body Worn Speech Processor (BWSP) and Receiver Stimulator. The prototype model of Receiver Stimulator for Auditory Prosthesis (RSAP) consists of Speech Data Decoder, DAC, ADC, constant...

  4. Fracture embolization of a Duromedics mitral prosthesis.

    OpenAIRE

    Baumgartner, F J; Munro, A I; Jamieson, W R

    1997-01-01

    The Duromedics bileaflet pyrolitic carbon mechanical prosthesis was introduced by Hemex in 1982 and subsequently acquired by Baxter. This communication documents a case of sudden leaflet fracture of a Duromedics mitral valve 48 months after implantation, which was managed successfully by replacement with a St. Jude Medical mechanical prosthesis. The patient presented in acute distress with paroxysmal atrial tachycardia and pulmonary edema. Transesophageal echocardiography was used to diagnose...

  5. Humidity and Cage and Bedding Temperatures in Unoccupied Static Mouse Caging after Steam Sterilization

    OpenAIRE

    Ward, Gina M; Cole, Kelly; Faerber, Jennifer; Hankenson, F Claire

    2009-01-01

    Contemporary rodent caging and equipment often are sterilized by steam autoclaves prior to use in facilities. This work assessed the microenvironment of unoccupied static mouse cages after steam sterilization to determine when internal temperatures had cooled to levels appropriate for rodent housing. Polycarbonate static cages containing food and corncob bedding were stacked (10 rows × 7 columns) in duplicate (front and back; n = 140 cages) on a storage truck and autoclaved to 249 °F (121 °C)...

  6. Friction moment analysis of space gyroscope bearing with ribbon cage under ultra-low oscillatory motion

    OpenAIRE

    Jiang Shaona; Chen Xiaoyang; Gu Jiaming; Shen Xuejin

    2014-01-01

    This paper presents the model of calculating the total friction moment of space gyroscope ball bearings which usually work under ultra-low oscillatory motion and are very sensitive to the friction moment. The aim is to know the proportion of the friction moment caused by each frictional source in the bearing’s total friction moment, which is helpful to optimize the bearing design to deduce the friction moment. In the model, the cage dynamic equations considering six degree-of-freedom and the ...

  7. MIPP Plastic Ball electronics upgrade

    International Nuclear Information System (INIS)

    An upgrade electronics design for Plastic Ball detector is described. The Plastic Ball detector was a part of several experiments in the past and its back portion (proposed to be used in MIPP) consists of 340 photomultipliers equipped with a sandwich scintillator. The scintillator sandwich has fast and slow signal component with decay times 10 ns and 1 (micro)s respectively. The upgraded MIPP experiment will collect up to 12,000 events during each 4 second spill and read them out in ∼50 seconds between spills. The MIPP data acquisition system will employ deadtime-less concept successfully implemented in Muon Electronics of Dzero experiment at Fermilab. An 8-channel prototype design of the Plastic Ball Front End (PBFE) implementing these requirements is discussed. Details of the schematic design, simulation and prototype test results are discussed.

  8. MIPP Plastic Ball electronics upgrade

    International Nuclear Information System (INIS)

    An upgrade electronics design for Plastic Ball detector is described. The Plastic Ball detector was a part of several experiments in the past and its back portion (proposed to be used in Main Injector Particle Production (MIPP)) consists of 340 photomultipliers equipped with a sandwich scintillator. The scintillator sandwich has fast and slow signal component with decay times 10 ns and 1 μs, respectively. The upgraded MIPP experiment will collect up to 12,000 events during each 4 s spill and read them out in ∼50 s between spills. The MIPP data acquisition system will employ deadtime-less concept successfully implemented in Muon Electronics of Dzero experiment at Fermilab An 8-channel prototype design of the Plastic Ball Front-End (PBFE) implementing these requirements is discussed. Details of the schematic design, simulation and prototype test results are discussed.

  9. Berkeley High-Resolution Ball

    International Nuclear Information System (INIS)

    Criteria for a high-resolution γ-ray system are discussed. Desirable properties are high resolution, good response function, and moderate solid angle so as to achieve not only double- but triple-coincidences with good statistics. The Berkeley High-Resolution Ball involved the first use of bismuth germanate (BGO) for anti-Compton shield for Ge detectors. The resulting compact shield permitted rather close packing of 21 detectors around a target. In addition, a small central BGO ball gives the total γ-ray energy and multiplicity, as well as the angular pattern of the γ rays. The 21-detector array is nearly complete, and the central ball has been designed, but not yet constructed. First results taken with 9 detector modules are shown for the nucleus 156Er. The complex decay scheme indicates a transition from collective rotation (prolate shape) to single- particle states (possibly oblate) near spin 30 h, and has other interesting features

  10. Body image and prosthesis satisfaction in the lower limb amputee.

    OpenAIRE

    Murray, Craig; Fox, Jezz

    2002-01-01

    Purpose: This study examines the relationship between prosthesis satisfaction and body image in lower limb prosthesis users, and the gendered variations within these relationships. Method: A total of 44 valid responses were obtained to an Internet survey regarding prosthesis satisfaction, body image, and phantom pain. Spearman Rho correlations were calculated for these three domains. Results: Moderate to high negative correlations were observed between Body Image Disturbance and Prosthesis Sa...

  11. Experimental Recognition of Loading Character of Transtibial Prosthesis

    OpenAIRE

    Paloušek, David; Návrat, Tomáš; Rosický, Jiří; Krejčí, Petr; Houfek, Martin

    2008-01-01

    This paper deals with experimental simulation of mechanical properties of transtibial prosthesis. Artificial limb allows patient standing and moving without of using others supporting devices. Therefore, patient returns back to common and active life. Design and prosthesis properties decide about comfort, safeness and reliability of prosthesis. The article summarizes a conclusion of preliminary experiment, which was performed to measurement procedure of prosthesis strain (for real loading of ...

  12. Implant-Retained Auricular Prosthesis: A Case Report

    OpenAIRE

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  13. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2014-11-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  14. Conventional X-ray after shoulder prosthesis

    International Nuclear Information System (INIS)

    Three types of shoulder prostheses are commonly used to cover the different indications of shoulder joint replacements: classical modular, inverse and cup. The modular prosthesis can replace the glenoid as well as the humeral head components. Exact visualization of the interface between the glenoid component and bone (or cement-bone interface) is necessary to detect osteolysis, which is relatively common. Therefore, it is mandatory to make true AP and axial projections. When describing the humeral component, the interface between bone and implant must again be considered. Additionally, the position of the humeral head in relation to the glenoid has to be noted. The glenoid component is usually fixed by screws to the bone and an osteolysis is often present at the inferior pole of the glenoid component due to prosthesis bone notching. If the implants are modular devices (classic modular prosthesis, inverse shoulder prosthesis) there is the possibility of dissociation of components and any suspicion of this should be reported. In case of reporting the conventional x-ray of cup prosthesis, the bone implant interface should be mentioned. Again the position of the humeral head to the glenoid requires attention. In all types of prostheses, dislocation of the glenohumeral joint is obvious and has to be addressed in the medical report. (orig.)

  15. Therapeutical attitudes in tooth supported overdentures with ball attachements. Case report.

    Science.gov (United States)

    Țâncu, A M; Melescanu Imre, M; Preoteasa, C T; Preoteasa, E

    2014-01-01

    Tooth supported overdenture with ball attachments has a number of advantages in prosthetics, but presents some difficulties as well, which sometimes make impossible the use of these anchoring systems; these difficulties should be well known. In this regard we present a suggestive case. It is the case of a patient, aged 57, who came for treatment, suffering from subtotal maxillary and mandibular edentulism (present 11 and 21, respectively 33 and 43), previously having an overdenture prosthesis on natural teeth, with special systems - ball attachment type, dissatisfied with the treatment (due to repeated fractures and functional intolerance to dentures). Clinical examination revealed an increase of the vertical dimension of occlusion and reduced prosthetic space at a correct, functional DVO value, aspects that were explaining the patient's reported complaints. As a therapeutic approach, having into consideration the balance conditions that were favorable for complete dentures and the large ball attachments volume, which did not allow keeping them at a functional DVO at any of the jaws, and the relatively young age of the patient, it was decided to remove the ball attachments and to keep the teeth for a simple overdenture, both to the maxillar and the mandible, over coronary reduced teeth, enough to allow the denture thickness at a functional DVO. Good end result of prosthetics, with stable, functional dentures, which were well tolerated and offered satisfaction to the patient, have led to an increased quality of life. PMID:27057258

  16. Hydraulic-Ball (HY-Ball) Control System

    International Nuclear Information System (INIS)

    The Hy-Ball control system consists of a large number of small tubes vertically penetrating the active core region; the tubes contain movable poison elements (either spherical or cylindrical), which are hydraulically lifted upward from within the active core region to increase core reactivity. Reactor water is the actuating fluid. Hy-Ball columns occupy fuel-element lattice positions in a homogeneous fuel-element configuration. This configuration, with finely subdivided control elements, practically eliminates local water-hole power peaking and provides good control of the radial power distribution. By limitation of the amount of reactivity controlled by a single Hy-Ball column assembly to 0.1% or less, it is unnecessary to operate the poison elements in any position other than either the fully-inserted or fully-withdrawn positions. Elimination of intermediate positions results in simplicity of the system and avoids the inherent axial power perturbation resulting from partially inserted control elements. Physics studies indicate that up to about 40% more power can be obtained from a Hy-Ball-controlled core than from a core with conventional control rods. Tests simulating all reactor operating conditions except radiation are being performed for evaluation of costs, operational characteristics and long-term reliability effects. (author)

  17. 21 CFR 874.3695 - Mandibular implant facial prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mandibular implant facial prosthesis. 874.3695... facial prosthesis. (a) Identification. A mandibular implant facial prosthesis is a device that is... made of materials such as stainless steel, tantalum, titanium, cobalt-chromium based...

  18. 21 CFR 874.3450 - Partial ossicular replacement prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Partial ossicular replacement prosthesis. 874.3450 Section 874.3450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... replacement prosthesis. (a) Identification. A partial ossicular replacement prosthesis is a device intended...

  19. Fabrication of temporary speech bulb prosthesis: A clinical report

    OpenAIRE

    Kasim Mohamed, K.; Anand Kumar, V.; Devi, N; T V Padmanaban

    2010-01-01

    Maxillofacial prosthesis is an art and science which not only replaces the lost structure sometimes it restores the functions also. Pharyngeal obturator is a prosthesis which closes the palatal and pharyngeal defects and improving the speech and other function. The following case report discusses palatopharyngeal insufficiency, impression procedures, fabrication of prosthesis and improvements in speech.

  20. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint polymer constrained prosthesis. 888... constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended... generic type of device includes prostheses that consist of a single flexible across-the-joint...

  1. 21 CFR 884.3650 - Fallopian tube prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fallopian tube prosthesis. 884.3650 Section 884.3650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... § 884.3650 Fallopian tube prosthesis. (a) Identification. A fallopian tube prosthesis is a...

  2. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Glenoid fossa prosthesis. 872.3950 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification. A glenoid fossa prosthesis is a device that is intended to be implanted in the...

  3. 21 CFR 890.3500 - External assembled lower limb prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External assembled lower limb prosthesis. 890.3500... External assembled lower limb prosthesis. (a) Identification. An external assembled lower limb prosthesis... the lower extremity. Examples of external assembled lower limb prostheses are the following:...

  4. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mandibular condyle prosthesis. 872.3960 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw...

  5. Fabrication of a Functional Finger Prosthesis With Simple Attachment

    OpenAIRE

    Pattanaik, Bikash; Pattanaik, Seema

    2012-01-01

    Finger prosthesis is more acceptable by the patient when it allows some of the movement in the prosthesis along with the restoration of a natural appearance to the lost structures of the patient. This article describes a custom-fabricated, custom-colored prostheses made from silicone elastomers with a simple attachment to make the prosthesis functional to imitate some of the movement.

  6. 21 CFR 872.3940 - Total temporomandibular joint prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Total temporomandibular joint prosthesis. 872.3940... prosthesis. (a) Identification. A total temporomandibular joint prosthesis is a device that is intended to be... and Drug Administration on or before March 30, 1999, for any total temporomandibular joint...

  7. 21 CFR 874.3495 - Total ossicular replacement prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Total ossicular replacement prosthesis. 874.3495 Section 874.3495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... replacement prosthesis. (a) Identification. A total ossicular replacement prosthesis is a device intended...

  8. 21 CFR 878.3750 - External prosthesis adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External prosthesis adhesive. 878.3750 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3750 External prosthesis adhesive. (a) Identification. An external prosthesis adhesive is a silicone-type adhesive intended to...

  9. 21 CFR 888.3720 - Toe joint polymer constrained prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint polymer constrained prosthesis. 888.3720 Section 888.3720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... prosthesis. (a) Identification. A toe joint polymer constrained prosthesis is a device made of...

  10. 21 CFR 870.3450 - Vascular graft prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular graft prosthesis. 870.3450 Section 870... prosthesis. (a) Identification. A vascular graft prosthesis is an implanted device intended to repair... Prostheses 510(k) Submissions.”...

  11. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint polymer constrained prosthesis. 888.3780 Section 888.3780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made...

  12. 21 CFR 888.3025 - Passive tendon prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Passive tendon prosthesis. 888.3025 Section 888...) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3025 Passive tendon prosthesis. (a) Identification. A passive tendon prosthesis is a device intended to be implanted made of silicon elastomer or...

  13. 21 CFR 874.3730 - Laryngeal prosthesis (Taub design).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Laryngeal prosthesis (Taub design). 874.3730... (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3730 Laryngeal prosthesis (Taub design). (a) Identification. A laryngeal prosthesis (Taub design) is a device intended to...

  14. 21 CFR 878.3530 - Silicone inflatable breast prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Silicone inflatable breast prosthesis. 878.3530... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3530 Silicone inflatable breast prosthesis. (a) Identification. A silicone inflatable breast prosthesis is a...

  15. Service life investigations of ball bearings at 1200C in a helium atmosphere

    International Nuclear Information System (INIS)

    The generally known rules for the layout of ball bearings do not yield in the case the bearings run in an helium atmosphere contaminated with impurities in the range of microbars. Therefore the layout of bearings put into action in helium has to be supported by tests carried out in a similar environment and for similar loads. With the aim to support the selection of lubricants and the design of the bearings in regard to the economical point of view, the basic principles of tribology in helium have been compiled and forty ball bearings have been tested at 900C and 1200C in helium. The applied loads comply with the usual values in machine construction. The tests show as result that ball bearings suitable for the different fields of applications in helium can be produced by simply exchanging the cages of standardized bearings. Reliable 107 revolutions have been obtained for different materials, also for cages made out of soft metals such as lead bronze, suitable in a radiation environment. In addition lubricants have been tested in order to find out the limits of suitability. (orig.)

  16. Aligner for Elastic Collisions of Dropped Balls.

    Science.gov (United States)

    Mellen, Walter Roy

    1995-01-01

    Discusses an aligner that permits dropping a stack of any number of balls of different sizes, elasticities, hardnesses, or types to observe the rebound of the top ball. Experimental results allow a reasonable comparison with theory. (MVL)

  17. Plutonium destruction with pebble bed type HTGRs using Pu burner balls and breeder balls

    International Nuclear Information System (INIS)

    It was made clear that pebble bed type HTGRs using Pu burner balls (pu balls) and breeder balls (Th balls) possesses a potential to burn weapons-grade Pu to 740 Gwd/TPu. The total amounts of Pu and 239Pu of can reduced to about 20 and 1%, respectively. (author). 10 refs, 4 figs, 2 tabs

  18. Laboratory-produced ball lightning

    Science.gov (United States)

    Golka, Robert K., Jr.

    1994-05-01

    For 25 years I have actively been searching for the true nature of ball lightning and attempting to reproduce it at will in the laboratory. As one might expect, many unidentified lights in the atmosphere have been called ball lightning, including Texas Maffa lights (automobile headlights), flying saucers (UFOs), swamp gas in Ann Arbor, Michigan, etc. For 15 years I thought ball lightning was strictly a high-voltage phenomenon. It was not until 1984 when I was short-circuiting the electrical output of a diesel electric railroad locomotive that I realized that the phenomenon was related more to a high current. Although I am hoping for some other types of ball lightning to emerge such as strictly electrostatic-electromagnetic manifestations, I have been unlucky in finding laboratory provable evidence. Cavity-formed plasmodes can be made by putting a 2-inch burning candle in a home kitchen microwave oven. The plasmodes float around for as long as the microwave energy is present.

  19. A Conjecture Concerning Ball Lightning

    CERN Document Server

    Sturrock, P A

    2016-01-01

    There is at present no theory that can explain the curious properties of ball lightning. This suggests that we may not be using the most appropriate concepts. The concept of a 'parallel space' may point the way to a valid theory.

  20. Generation of Laboratory Ball Lightning

    International Nuclear Information System (INIS)

    The phenomenon of energy conversion in the streams of directed electrons and ions into electromagnetic radiation was found out experimentally and proved theoretically. The direct proofs of the domain mechanism of the charged particles acceleration and mechanism of ball lightning generation were obtained and the theoretical calculations were refined

  1. LHC gets the ball rolling

    CERN Multimedia

    2007-01-01

    1. The multidisciplinary team responsible for the RF ball project to check the interconnections. From left to right: Rhodri Jones (AB/BI), Eva Calvo (AB/BI), Francesco Bertinelli (AT/MCS), Sonia Bartolome Jimenez (TS/IC), Sylvain Weisz (TS/IC), Paul Cruikshank (AT/VAC), Willemjan Maan (AT/VAC), Alain Poncet (AT/MCS), Marek Gasior (AB/BI).2. During the tests the ball is inserted very carefully into the vacuum chamber.1. Le groupe pluridisciplinaire qui a mené le projet de balle RF pour vérifier les interconnexions avec, de gauche à droite, Rhodri Jones (AB/BI), Eva Calvo (AB/BI), Francesco Bertinelli (AT/MCS), Sonia Bartolome Jimenez (TS/IC), Sylvain Weisz (TS/IC), Paul Cruikshank (AT/VAC), Willemjan Maan (AT/VAC), Alain Poncet (AT/MCS) et Marek Gasior (AB/BI).2. Lors des tests, la balle est insérée dans la chambre à vide avec beaucoup de précaution.

  2. SECRET OF A BALL LIGHTNING

    Directory of Open Access Journals (Sweden)

    E.V. Savich

    2013-04-01

    Full Text Available A ball lightning is a natural phenomenon that occurs at a streak lightning stroke with its action by thermal and magnetic energy releasing around the streak lightning channel and transforming, in the end, the surrounding air into a steam cloud that transits into ferroelectric state under the magnetic field action.

  3. Secrets of the Crystal Ball

    Science.gov (United States)

    Croucher, John S.

    2007-01-01

    This article describes how a crystal ball known as "The Flash Mind Reader" is played. "The Flash Mind Reader" is a mathematics game in which the player is invited to select any-two digit number and then subtract the sum of these two digits from the original number. A chart is provided in which the (adjusted) number they obtained will have a symbol…

  4. Active cage model of glassy dynamics.

    Science.gov (United States)

    Fodor, Étienne; Hayakawa, Hisao; Visco, Paolo; van Wijland, Frédéric

    2016-07-01

    We build up a phenomenological picture in terms of the effective dynamics of a tracer confined in a cage experiencing random hops to capture some characteristics of glassy systems. This minimal description exhibits scale invariance properties for the small-displacement distribution that echo experimental observations. We predict the existence of exponential tails as a crossover between two Gaussian regimes. Moreover, we demonstrate that the onset of glassy behavior is controlled only by two dimensionless numbers: the number of hops occurring during the relaxation of the particle within a local cage and the ratio of the hopping length to the cage size. PMID:27575182

  5. Production of porous coating on a prosthesis

    Science.gov (United States)

    Sump, Kenneth R.

    1987-01-01

    Preselected surface areas of a prosthesis are covered by a blend of matching primary metallic particles and expendable particles. The particles are compressed and heated to assure that deformation and metallurgical bonding occurs between them and between the primary particles and the surface boundaries of the prosthesis. Porosity is achieved by removal of the expendable material. The result is a coating including discrete bonded particles separated by a network of interconnected voids presenting a homogeneous porous coating about the substrate. It has strength suitable for bone implant usage without intermediate adhesives, and adequate porosity to promote subsequent bone ingrowth.

  6. Fabrication of a custom ocular prosthesis

    Directory of Open Access Journals (Sweden)

    Tania Sethi

    2014-01-01

    Full Text Available Defects of the eye may follow removal of a part of or the entire orbit. This results in the patient becoming visually, esthetically and psychologically handicapped. Restoring the defect with a silicone- or acrylic-based prosthesis not only restores esthetics but also gives back the lost confidence to the patient. This is a case report of a patient with a `pthisical eye` and details the steps in fabrication of an ocular prosthesis. Particular attention has been given to the laboratory process in this technique to minimize the residual monomer content in the artificial eye.

  7. Compositions containing borane or carborane cage compounds and related applications

    Science.gov (United States)

    Bowen, III, Daniel E; Eastwood, Eric A

    2013-05-28

    Compositions comprising a polymer-containing matrix and a filler comprising a cage compound selected from borane cage compounds, carborane cage compounds, metal complexes thereof, residues thereof, mixtures thereof, and/or agglomerations thereof, where the cage compound is not covalently bound to the matrix polymer. Methods of making and applications for using such compositions are also disclosed.

  8. Compositions containing borane or carborane cage compounds and related applications

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, III, Daniel E; Eastwood, Eric A

    2014-11-11

    Compositions comprising a polymer-containing matrix and a filler comprising a cage compound selected from borane cage compounds, carborane cage compounds, metal complexes thereof, residues thereof, mixtures thereof, and/or agglomerations thereof, where the cage compound is not covalently bound to the matrix polymer. Methods of making and applications for using such compositions are also disclosed.

  9. Compositions containing borane or carborane cage compounds and related applications

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, III, Daniel E.; Eastwood, Eric A.

    2015-09-15

    Compositions comprising a polymer-containing matrix and a filler comprising a cage compound selected from borane cage compounds, carborane cage compounds, metal complexes thereof, residues thereof, mixtures thereof, and/or agglomerations thereof, where the cage compound is not covalently bound to the matrix polymer. Methods of making and applications for using such compositions are also disclosed.

  10. Aerodynamics of a golf ball with grooves

    Science.gov (United States)

    Kim, Jooha; Son, Kwangmin; Choi, Haecheon

    2009-11-01

    It is well known that the drag on a dimpled ball is much lower than that on smooth ball. Choi et al. (Phys. Fluids, 2006) showed that turbulence is generated through the instability of shear layer separating from the edge of dimples and delays flow separation. Based on this mechanism, we devise a new golf ball with grooves on the surface but without any dimples. To investigate the aerodynamic performance of this new golf ball, an experiment is conducted in a wind tunnel at the Reynolds numbers of 0.5 x10^5 - 2.7 x10^5 and the spin ratios (ratio of surface velocity to the free-stream velocity) of α=0 - 0.5, which are within the ranges of real golf-ball velocity and spin rate. We measure the drag and lift forces on the grooved ball and compare them with those of smooth ball. At zero spin, the drag coefficient on the grooved ball shows a rapid fall-off at a critical Reynolds number and maintains a minimum value which is lower by 50% than that on smooth ball. At non-zero α, the drag coefficient on the grooved ball increases with increasing α, but is still lower by 40% than that on smooth ball. The lift coefficient on the grooved ball increases with increasing α, and is 100% larger than that on smooth ball. The aerodynamic characteristics of grooved ball is in general quite similar to that of dimpled ball. Some more details will be discussed in the presentation.

  11. Rehabilitation of Glossectomy Cases with Tongue Prosthesis: A Literature Review.

    Science.gov (United States)

    Balasubramaniam, Muthu Kumar; Chidambaranathan, Ahila Singaravel; Shanmugam, Gokul; Tah, Rajdeep

    2016-02-01

    Tongue is the only movable muscular organ without any bone in the human body. It has very important role in perception of taste and sensations like touch, pressure, heat and cold. The purpose of the article is to review various types of tongue prosthesis and their clinical applications. This review helps the clinician to choose the appropriate type of tongue prosthesis for different clinical situations, retention of tongue prosthesis and material selection for each type of prosthesis. A broad search of published literature was performed using the keyword glossectomy, glossal prosthesis and tongue prosthesis from 1980 to 2014 in Medline, Google scholar, internet and text book. This review gives basic knowledge of glossal prosthesis and selection of the same for various clinical conditions. PMID:27042596

  12. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    OpenAIRE

    Handford, Matthew L.; Manoj Srinivasan

    2016-01-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by si...

  13. Synthesis of caged Garcinia xanthone analogues

    OpenAIRE

    Cho, Woo Cheal

    2009-01-01

    A new synthetic strategy is developed toward the synthesis of the caged Garcinia xanthone analogues. The key to the strategy is a Pd-catalyzed reverse prenylation reaction. This new synthetic approach provides a rapid and efficient access to various caged analogues, including cluvenone which is known to induce apoptosis and exhibit significant cytotoxicity in various cancer cell lines. Evaluation of their growth inhibitory activities also leads to identification of the pharmacophoric motif of...

  14. Welfare assessment of laying hens in furnished cages and non-cage systems: an on-farm comparison

    NARCIS (Netherlands)

    Rodenburg, T.B.; Tuyttens, F.; Reu, de K.; Herman, L.; Zoons, J.; Sonck, B.

    2008-01-01

    From 2012 onwards, all laying hens in Europe will need to be housed either in furnished cages or non-cage systems (aviaries or floor-housing systems). In terms of animal welfare, furnished cages and non-cage systems both have advantages and disadvantages. Data on direct comparisons between the two,

  15. Ceramic Rail-Race Ball Bearings

    Science.gov (United States)

    Balzer, Mark A.; Mungas, Greg S.; Peters, Gregory H.

    2010-01-01

    Non-lubricated ball bearings featuring rail races have been proposed for use in mechanisms that are required to function in the presence of mineral dust particles in very low-pressure, dry environments with extended life. Like a conventional ball bearing, the proposed bearing would include an inner and an outer ring separated by balls in rolling contact with the races. However, unlike a conventional ball bearing, the balls would not roll in semi-circular or gothic arch race grooves in the rings: instead, the races would be shaped to form two or more rails (see figure). During operation, the motion of the balls would push dust particles into the spaces between the rails where the particles could not generate rolling resistance for the balls

  16. Fusion around cervical disc prosthesis: case report.

    NARCIS (Netherlands)

    Bartels, R.H.M.A.; Donk, R.

    2005-01-01

    OBJECTIVE AND IMPORTANCE: Cervical arthroplasty is a relatively new method to maintain motion after cervical anterior discectomy. Two cases are presented in which bony fusion occurred around a cervical disc prosthesis. CLINICAL PRESENTATION: A 30-year-old man and a 49-year-old woman underwent a righ

  17. Argus II retinal prosthesis system: An update.

    Science.gov (United States)

    Rachitskaya, Aleksandra V; Yuan, Alex

    2016-09-01

    This review focuses on a description of the Argus II retinal prosthesis system (Argus II; Second Sight Medical Products, Sylmar, CA) that was approved for humanitarian use by the FDA in 2013 in patients with retinitis pigmentosa with bare or no light perception vision. The article describes the components of Argus II, the studies on the implant, and future directions. PMID:26855177

  18. Determining delay created by multifunctional prosthesis controllers

    Directory of Open Access Journals (Sweden)

    Todd R. Farrell, PhD

    2011-07-01

    Full Text Available I am writing to express a concern that my colleagues from previous laboratories at Northwestern University/Rehabilitation Institute of Chicago (RIC and I have shared for a number of years related to multifunctional prosthesis control. Previous investigations have used a variety of analysis window attributes for their multifunctional prosthesis controllers [1-8]. Researchers have varied the length of the analysis window, the amount of overlap between consecutive windows, and the number of majority votes used in the postprocessing of the classifier decisions. However, we believe that many researchers have made decisions about these attributes with little regard for the overall delay created in the real-time system. (Note that the term classifier typically refers to an element of the controller that uses the inputs provided to it, e.g., electromyographic [EMG] signals, force sensor data, and position sensor data to decide which joint(s of the prosthesis should be actuated. For example, Peleg et al. performed classification decisions on data up to 1.4 seconds after the onset of the contraction [9]. This classifier would require its user to wait on the order of seconds for Peleg et al.'s prosthesis to respond, which would likely be quite frustrating for the user. We are not suggesting that new algorithms should not be explored simply because they may create substantial delays. However, we do believe that these delays should be considered and discussed in each article that is published on this topic. While a particular classifier may create a 1 percent increase in classification accuracy, if it cannot add this increase in accuracy in a reasonable amount of time, it may be a "nonstarter." Continuing in this vein, we would like to discuss some findings that we believe will allow prosthesis controller designers to better understand how their controllers will behave in real time. (For the purpose of this editorial, further use of "we" and "our" indicates

  19. Ball Nut Preload Diagnosis of the Hollow Ball Screw through Sensed Current Signals

    Directory of Open Access Journals (Sweden)

    Yi-Cheng Huang

    2014-08-01

    Full Text Available This paper studies the diagnostic results of hollow ball screws with different ball nut preload levels through the Hilbert-Huang transform (HHT and multiscale entropy (MSE process. The method is tested using ball screw pretension and an oil cooling circulation system. MSE was used to determine the hollow ball screw preload status through the servo motor current signals. Ball screws with maximum dynamic preloads of 2%, 4%, and 6% were predesigned, manufactured, and tested. Signal patterns are discussed and revealed by the Hilbert Spectrum. Different preload features are extracted using HHT and MSE. The irregularity development of the ball screw driving motion current can be discriminated and abstracted via MSE based on complexity perception. Experimental results show that the proposed approach can successfully predict the prognostic status of ball nut preload. A comparative evaluation of MSE allows for smart sensing for the health of the ball screw. This method effectively diagnoses the ball nut preload status.

  20. Exact Wavelets on the Ball

    CERN Document Server

    Leistedt, B

    2012-01-01

    We develop an exact wavelet transform on the three-dimensional ball (i.e. on the solid sphere), which we name the flaglet transform. For this purpose we first construct an exact harmonic transform on the radial line using damped Laguerre polynomials and develop a corresponding quadrature rule. Combined with the spherical harmonic transform, this approach leads to a sampling theorem on the ball and a novel three-dimensional decomposition which we call the Fourier-Laguerre transform. We relate this new transform to the well-known Fourier-Bessel decomposition and show that band-limitness in the Fourier-Laguerre basis is a sufficient condition to compute the Fourier-Bessel decomposition exactly. We then construct the flaglet transform on the ball through a harmonic tiling, which is exact thanks to the exactness of the Fourier-Laguerre transform (from which the name flaglets is coined). The corresponding wavelet kernels have compact localisation properties in real and harmonic space and their angular aperture is i...

  1. Studies On Falling Ball Viscometry

    CERN Document Server

    Singh, Amit Vikram; Gupta-Bhaya, Pinaki

    2012-01-01

    A new method of accurate calculation of the coefficient of viscosity of a test liquid from experimentally measured terminal velocity of a ball falling in the test liquid contained in a narrow tube is described. The calculation requires the value of a multiplicative correction factor to the apparent coefficient of viscosity calculated by substitution of terminal velocity of the falling ball in Stokes formula. This correction factor, the so-called viscosity ratio, a measure of deviation from Stokes limit, arises from non-vanishing values of the Reynolds number and the ball/tube radius ratio. The method, valid over a very wide range of Reynolds number, is based on the recognition of a relationship between two measures of wall effect, the more widely investigated velocity ratio, defined as the ratio of terminal velocity in a confined medium to that in a boundless medium and viscosity ratio. The calculation uses two recently published correlation formulae based on extensive experimental results on terminal velocit...

  2. Ball Screw Actuator Including a Stop with an Integral Guide

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  3. Robotic Arm-The Ball Catcher

    Directory of Open Access Journals (Sweden)

    J.C.Titarmare

    2014-02-01

    Full Text Available Catching a thrown ball with a hand is not easy – neither for humans nor for robots. It demands for a tight interplay of skills in mechanics, control, planning and visual sensing to reach the necessary precision in space and time. Because of this, ball catching has been used for almost 20 years now as a challenging benchmark system to develop and test robotics key technologies. Here we propose a high speed and intelligent robotic arm set up which will capable enough to catch the short range thrown ball in specified environment. The main technique used is a stereo vision system to tracks the ball and predicts the balls trajectory then the point and time required to reach at destination point, and in which orientation the robot should intercept the ball on its trajectory, is determined. Once robots calculate the desired parameters it will try to catch the ball. Expected outcome of the proposed system is to catch the ball by calculating the coming ball path using computer vision techniques and move the robotic arm in order to catch the ball

  4. Structural dynamic analysis of a ball joint

    Science.gov (United States)

    Hwang, Seok-Cheol; Lee, Kwon-Hee

    2012-11-01

    Ball joint is a rotating and swiveling element that is typically installed at the interface between two parts. In an automobile, the ball joint is the component that connects the control arms to the steering knuckle. The ball joint can also be installed in linkage systems for motion control applications. This paper describes the simulation strategy for a ball joint analysis, considering manufacturing process. Its manufacturing process can be divided into plugging and spinning. Then, the interested responses is selected as the stress distribution generated between its ball and bearing. In this paper, a commercial code of NX DAFUL using an implicit integration method is introduced to calculate the response. In addition, the gap analysis is performed to investigate the fitness, focusing on the response of the displacement of a ball stud. Also, the optimum design is suggested through case studies.

  5. Adiabatic Invariance of Oscillons/I-balls

    CERN Document Server

    Kawasaki, Masahiro; Takeda, Naoyuki

    2015-01-01

    Real scalar fields are known to fragment into spatially localized and long-lived solitons called oscillons or $I$-balls. We prove the adiabatic invariance of the oscillons/$I$-balls for a potential that allows periodic motion even in the presence of non-negligible spatial gradient energy. We show that such potential is uniquely determined to be the quadratic one with a logarithmic correction, for which the oscillons/$I$-balls are absolutely stable. For slightly different forms of the scalar potential dominated by the quadratic one, the oscillons/$I$-balls are only quasi-stable, because the adiabatic charge is only approximately conserved. We check the conservation of the adiabatic charge of the $I$-balls in numerical simulation by slowly varying the coefficient of logarithmic corrections. This unambiguously shows that the longevity of oscillons/$I$-balls is due to the adiabatic invariance.

  6. Development and clinical application of a new testicular prosthesis

    Institute of Scientific and Technical Information of China (English)

    Ye Ning; Zhikang Cai; Huixing Chen; Ping Ping; Peng Li; Zhong Wang; Zheng Li

    2011-01-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China.The prosthesis was produced in different sizes to imitate the normal testis of the patient.To investigate the effects and safety of the testicular prosthesis,20 patients receiving testicular prosthesis implantation were recruited for this study.Follow-up after 6 months revealed no complications in the patients.All the patients answered that they were satisfied with their body image and the position of the implants,19 patients were satisfied with the size and 16 patients were satisfied with the weight.These results show that the testicular prosthesis used in this study can meet patient's expectations.Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation.The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction.

  7. Multifractal properties of ball milling dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Budroni, M. A., E-mail: mabudroni@uniss.it; Pilosu, V.; Rustici, M. [Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, Sassari 07100 (Italy); Delogu, F. [Dipartimento di Ingegneria Meccanica, Chimica, e dei Materiali, Università degli Studi di Cagliari, via Marengo 2, Cagliari 09123 (Italy)

    2014-06-15

    This work focuses on the dynamics of a ball inside the reactor of a ball mill. We show that the distribution of collisions at the reactor walls exhibits multifractal properties in a wide region of the parameter space defining the geometrical characteristics of the reactor and the collision elasticity. This feature points to the presence of restricted self-organized zones of the reactor walls where the ball preferentially collides and the mechanical energy is mainly dissipated.

  8. From Schwinger Balls to Curved Space

    CERN Document Server

    Allahbakhshi, Davood

    2016-01-01

    It is shown that the Reissner-Nordstrom black hole is also a gravitational Schwinger ball. It is also shown that both massless and massive-particle gravitational Schwinger balls are thermodynamic systems by deriving the first law of thermodynamics for them. Inconsistency between classical geometrical and microscopic definitions of the horizon is discussed. We propose a new metric, more consistent with microscopic picture of black hole, as gravitational Schwinger ball, by speculations. It has some interesting features.

  9. Dental prosthesis and buccal lesions in the elderly

    OpenAIRE

    Beatriz García Alpizar; Mikhail Benet Rodíguez; Eduardo Enrique Castillo Betancourt

    2010-01-01

    Fundament: Buccal lesions in the elderly are very frequent and they constitute a problem of health due to the consequences that cause. Objective: to describe the characteristics of the removable prosthesis used by the population of 60 and more years age and their relationship with the lesions of the oral mucosa. Methods: We carried out a study descriptive of cross section in 125 elderly with oral prosthesis. The characteristics of the removable prosthesis were described and their relationship...

  10. Difficult factors in Management of Impacted Dental Prosthesis in Esophagus

    OpenAIRE

    Efiaty A. Soepardi

    2005-01-01

    A dental prosthesis which ingested and impacted in esophagus, is an emergency case and life threatening, so require immediate esophagoscopy intervention for removing. The objective of this study is to assess some factors can caused dtfficulties in diagnosing and treating the ingested and impacted dental prosthesis in the esophagus and their complications. This retrospective study analyzed patient’s chart whose underwent esophagoscopy for removing the impacted dental prosthesis in Dr. Cipto Ma...

  11. Self-contained inflatable penile prosthesis: magnetic resonance appearance

    International Nuclear Information System (INIS)

    The appearance of an inflatable penile prosthesis, visualized on a short tau inversion recovery sequence, is reported, in a patient who had magnetic resonance imaging for pelvic pain subsequent to radical cystoprostatectomy for bladder carcinoma. With suppression of adjacent fat signal, the prosthesis is well delineated from adjacent structures. The fluid-containing cylinders of the prosthesis are of very bright signal intensity, with the relief valve assembly of low signal intensity. 5 refs., 2 figs

  12. Biodegradation and biocompatibility of a degradable chitosan vascular prosthesis

    OpenAIRE

    Kong, Xiaoying; Xu, Wenhua

    2015-01-01

    An instrument made by ourselves was used to fabricate biodegradable chitosan-heparin artificial vascular prosthesis with small internal diameter (2 mm) and different crosslinking degree from biodegradable chitosan, chitosan derivates and heparin. In vivo and in vitro degradation studies, inflammatory analysis and electron microscope scanning of this artificial vascular prosthesis were performed. It was observed that 50% of the prosthesis decomposed in vivo and was replaced by natural tissues....

  13. Correlation analysis between the interface membrane and loose hip prosthesis

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To analyze the cause of prosthesis loosening by observing the interface membranes harvested during the hip restoration operation. Methods A total of 28 specimens of interface membrane around the loose prosthesis were harvested from 28 patients undergoing the restoration of total hip replacement. All the specimens underwent the observation of appearance, light microscopy and scanning electronic microscopy(SEM). Results All the gaps around the loose prosthesis were filled with interface membrane of ...

  14. Design and Control of a Powered Transfemoral Prosthesis

    OpenAIRE

    Sup, Frank; Bohara, Amit; Goldfarb, Michael

    2008-01-01

    The paper describes the design and control of a transfemoral prosthesis with powered knee and ankle joints. The initial prototype is a pneumatically actuated powered-tethered device, which is intended to serve as a laboratory test bed for a subsequent self-powered version. The prosthesis design is described, including its kinematic optimization and the design of a three-axis socket load cell that measures the forces and moments of interaction between the socket and prosthesis. A gait controll...

  15. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    Directory of Open Access Journals (Sweden)

    Ataman Köse

    2014-01-01

    Full Text Available It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in literature. In our study, a 52-year-old male patient who had aspirated the front part of his lower dental prosthesis accidentally is presented and the foreign body is extracted by using rigid bronchoscopy. There are many causes of aspiration but dental prosthetic aspirations should be kept in mind during sleep. For this reason, dental apparatus must be taken out while asleep.

  16. Space orientation of total hip prosthesis

    International Nuclear Information System (INIS)

    A method for in vivo determination of orientation and relation in space of components of total hip prosthesis is described. The method allows for determination of the orientation of the prosthetic components in well defined anatomic planes of the body. Furthermore the range of free motion from neutral position to the point of contact between the edge of the acetabular opening and the neck of the femoral component can be determined in various directions. To assess the accuracy of the calculations a phantom prosthesis was studied in nine different positions and the measurements of the space oriented parameters according to the present method correlated to measurements of the same parameters according to Selvik's stereophotogrammetric method. Good correlation ws found. The role of prosthetic malpositioning and component interaction evaluated with the present method in the development of prosthetic loosening and displacement is discussed. (orig.)

  17. The plasma theory of ball lightning

    International Nuclear Information System (INIS)

    The high-energy density inside the ball lightning is due to existence of in ntense plasma oscillations and high kinetic and potential energy of electron gas which form a pulsating ball vibrating relative to the nearly stationary ionic ba all. At sublight velocities of electrons one can neglect the processes of their scattering and recombination. One obtains a relation between parameters of the plasma ball from the condition of equally of excess pressure of ions and that o Madelung forces. The high lifetime of the ball lighting is connected with smal ll Landau damping for the longest wave vibrations

  18. Coefficient of Restitution of Wet Tennis Balls

    OpenAIRE

    Eugene Jang; Tony Kim

    2014-01-01

    The coefficient of restitution of a damp tennis ball is of interest to tennis players. Using a spray bottle, water was added to a tennis ball and the mass of water on the wet ball was determined. The ball was then dropped from a fixed height of 0.86 m. The motion was recorded with a video camera and the bounce height was measured. Using the bounce height and the original height, the coefficient of restitution for that mass of added water was determined. The research found the mass of wa...

  19. Ball Bearing Stacking Automation System

    Directory of Open Access Journals (Sweden)

    Shafeequerrahman S . Ahmed

    2013-01-01

    Full Text Available This document is an effort to introduce the concept of automation in small scale industries and or small workshops that are involved in the manufacturing of small objects such as nuts, bolts and ball bearing in this case. This an electromechanical system which includes certain mechanical parts that involves one base stand on which one vertical metallic frame is mounted and hinged to this vertical stand is an in humanized effort seems inadequate in this era making necessary the use of Electronics, Computer in the manufacturing processes leading to the concept of Automated Manufacturing System (AMS.The ball bearing stack automation is an effort in this regard. In our project we go for stack automation for any object for example a ball bearing, be that is still a manual system there. It will be microcontroller based project control system equipped with microcontroller 89C51 from any manufacturer like Atmel or Philips. This could have been easily implemented if a PLC could be used for manufacturing the staking unit but I adopted the microcontroller based system so that some more modification in the system can be effected at will as to use the same hardware .Although a very small object i.e. ball bearig or small nut and fixture will be tried to be stacked, the system with more precision and more power handling capacity could be built for various requirements of the industry. For increasing more control capacity, we can use another module of this series. When the bearing is ready, it will be sent for packing. This is sensed by an inductive sensor. The output will be proceeds by PLC and microcontroller card which will be driving the assembly in order to put it into pads or flaps. This project will also count the total number of bearings to be packed and will display it on a LCD for real time reference and a provision is made using a higher level language using hyper terminal of the computer

  20. Gingival prosthesis: A treatment modality for recession

    OpenAIRE

    Pallavi Samatha Yalamanchili; Hemchand Surapaneni; Arunima Padmakumar Reshmarani

    2013-01-01

    Gingival recession caused due to periodontal disease disturbs patients because of sensitivity and esthetics. Gingival prosthesis may be fixed or removable and can be made from silicones, acrylics, composite resins or ceramics according to what is best suited for the case. The gingival veneer is esthetically appealing and easy to maintain. This case report describes the use of gingival veneer as a treatment modality for recession.

  1. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    OpenAIRE

    Ataman Köse; Dilek Kostak; Erol Aramagan; Aslıhan Durak; Nur Sezin Seçkin; Serdar Süha Dönmez; Hüseyin Melek

    2014-01-01

    It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in litera...

  2. Custom Ocular Prosthesis: A Palliative Approach

    OpenAIRE

    Prachi Thakkar; JR Patel; Rajesh Sethuraman; Narendra Nirmal

    2012-01-01

    The goal of palliative care is the achievement of the best quality of life for patients and their families. Eyes are generally the first features of the face to be noticed. Loss of an eye is a traumatic event which has a crippling effect on the psychology of the patient. Several ocular and orbital disorders require surgical intervention that may result in ocular defects. An ocular prosthesis is fabricated to restore the structure, function, and cosmetics of the defects created by such conditi...

  3. Trouble shooting with the Tracheo Esophageal Prosthesis

    OpenAIRE

    Thakar, A.; Bahadur, S

    2002-01-01

    Vocal rehabilitation of the laryngectomee can be dramatically improved by the Tracheo-Esophageal Puncture (TEP) technique. The greatest impediment to its increased use in our country has been the failure on the part of the Medical Community to provide these patients with day to day support and guidance on the use of the TEP prosthesis. This article seeks to address this deficiency and provides some guidance on the care and maintenance of the TEP.

  4. Phosphonate Based High Nuclearity Magnetic Cages.

    Science.gov (United States)

    Sheikh, Javeed Ahmad; Jena, Himanshu Sekhar; Clearfield, Abraham; Konar, Sanjit

    2016-06-21

    Transition metal based high nuclearity molecular magnetic cages are a very important class of compounds owing to their potential applications in fabricating new generation molecular magnets such as single molecular magnets, magnetic refrigerants, etc. Most of the reported polynuclear cages contain carboxylates or alkoxides as ligands. However, the binding ability of phosphonates with transition metal ions is stronger than the carboxylates or alkoxides. The presence of three oxygen donor sites enables phosphonates to bridge up to nine metal centers simultaneously. But very few phosphonate based transition metal cages were reported in the literature until recently, mainly because of synthetic difficulties, propensity to result in layered compounds, and also their poor crystalline properties. Accordingly, various synthetic strategies have been followed by several groups in order to overcome such synthetic difficulties. These strategies mainly include use of small preformed metal precursors, proper choice of coligands along with the phosphonate ligands, and use of sterically hindered bulky phosphonate ligands. Currently, the phosphonate system offers a library of high nuclearity transition metal and mixed metal (3d-4f) cages with aesthetically pleasing structures and interesting magnetic properties. This Account is in the form of a research landscape on our efforts to synthesize and characterize new types of phosphonate based high nuclearity paramagnetic transition metal cages. We quite often experienced synthetic difficulties with such versatile systems in assembling high nuclearity metal cages. Few methods have been emphasized for the self-assembly of phosphonate systems with suitable transition metal ions in achieving high nuclearity. We highlighted our journey from 2005 until today for phosphonate based high nuclearity transition metal cages with V(IV/V), Mn(II/III), Fe(III), Co(II), Ni(II), and Cu(II) metal ions and their magnetic properties. We observed that

  5. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report.

    Science.gov (United States)

    Shankaran, Gayatri; Deogade, Suryakant Chhagan; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography. PMID:27536331

  6. Development of Receiver Stimulator for Auditory Prosthesis

    Directory of Open Access Journals (Sweden)

    K. Raja Kumar

    2010-05-01

    Full Text Available The Auditory Prosthesis (AP is an electronic device that can provide hearing sensations to people who are profoundly deaf by stimulating the auditory nerve via an array of electrodes with an electric current allowing them to understand the speech. The AP system consists of two hardware functional units such as Body Worn Speech Processor (BWSP and Receiver Stimulator. The prototype model of Receiver Stimulator for Auditory Prosthesis (RSAP consists of Speech Data Decoder, DAC, ADC, constant current generator, electrode selection logic, switch matrix and simulated electrode resistance array. The laboratory model of speech processor is designed to implement the Continuous Interleaved Sampling (CIS speech processing algorithm which generates the information required for electrode stimulation based on the speech / audio data. Speech Data Decoder receives the encoded speech data via an inductive RF transcutaneous link from speech processor. Twelve channels of auditory Prosthesis with selectable eight electrodes for stimulation of simulated electrode resistance array are used for testing. The RSAP is validated by using the test data generated by the laboratory prototype of speech processor. The experimental results are obtained from specific speech/sound tests using a high-speed data acquisition system and found satisfactory.

  7. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Song [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Wang, Fei [School of Material Science and Engineering, China University of Mining and Technology, Xuzhou 221116 (China); Liao, Zhenhua [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Wang, Qingliang [School of Material Science and Engineering, China University of Mining and Technology, Xuzhou 221116 (China); Liu, Yuhong [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liu, Weiqiang, E-mail: weiqliu@hotmail.com [Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China)

    2015-10-01

    vitro cervical prosthesis simulations according to the literature. - Highlights: • Ball-on-socket contact configuration is designed to simulate an artificial cervical disk in structure. • The model with C-DLC mixed layer is tested based on in vitro simulation standard. • 3 running regimes (PSR, MR and SR) and 4 stages of T-n torque curves are observed. • The wear mechanism is a mix of surface scratch, adhesive wear and abrasive wear for PE. • The wear region and damage mechanism are different from those in ball-on-flat contact.

  8. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk

    International Nuclear Information System (INIS)

    vitro cervical prosthesis simulations according to the literature. - Highlights: • Ball-on-socket contact configuration is designed to simulate an artificial cervical disk in structure. • The model with C-DLC mixed layer is tested based on in vitro simulation standard. • 3 running regimes (PSR, MR and SR) and 4 stages of T-n torque curves are observed. • The wear mechanism is a mix of surface scratch, adhesive wear and abrasive wear for PE. • The wear region and damage mechanism are different from those in ball-on-flat contact

  9. Rehabilitation of a Patient with an Intra Oral Prosthesis and an Extra Oral Orbital Prosthesis Retained with Magnets

    OpenAIRE

    Pattanaik, Seema; Wadkar, Aarti P.

    2011-01-01

    This clinical case report deals with a rehabilitation of a patient with an extensive maxillary and orbital defect using an intra oral prosthesis obturating the maxillary defect and extra oral orbital prosthesis retained with rare-earth magnets for secondary retention; primary retention was derived by snug fit of the prosthesis to underlying and adjacent tissues. The rehabilitation resulted in improved function, esthetics and comfort to the patient thus enabling him to lead a normal life.

  10. Cage RACK ventilation options for laboratory animal facilities.

    Science.gov (United States)

    Stakutis, Richard E

    2003-09-01

    Individually ventilated cage systems have become the method of choice for housing rodents. The author describes the various options for cage ventilation, from using supply and exhaust fans to directly connecting the racks to the building ventilation system. PMID:12966448

  11. High-throughput Transcriptome analysis, CAGE and beyond

    KAUST Repository

    Kodzius, Rimantas

    2008-11-25

    1. Current research - PhD work on discovery of new allergens - Postdoctoral work on Transcriptional Start Sites a) Tag based technologies allow higher throughput b) CAGE technology to define promoters c) CAGE data analysis to understand Transcription - Wo

  12. Chemical contamination of animal feeding systems: evaluation of two caging systems and standard cage-washing equipment.

    Science.gov (United States)

    Fox, J G; Helfrich-Smith, M E

    1980-12-01

    Sodium fluorescein was added as a tracer to an ager gel diet which was fed for 5 day to 90 of 180 rats housed in two different polycarbonate caging systems, shoe-box cages and suspension solid-bottom cages. Cage racks, supplementary equipment, and case washer surfaces were analysed for fluorescein both before and after a complete wash and rinse cycle. Efficacy of washing was greater than 99% for both the inside and outside of the suspended cages and greater than 99% for the inside, but only 93% for the outside, of the shoe-box cages. The shoe-box cages, which were larger than the suspended cages, were spaced closer together on the washer rack, which may account for this variation in cleaning effectiveness. The cage washer surfaces and the water, which was recirculated during each cycle, also became contaminated with fluorescein. Strict adherence to proper cage-washing procedures and careful selection of cage design are important factors in controlling the potential for residual contamination of caging and cage-washing equipment. PMID:7464031

  13. Convective Cage Release in Model Colloidal Glasses.

    Science.gov (United States)

    Jacob, Alan R; Poulos, Andreas S; Kim, Sunhyung; Vermant, Jan; Petekidis, George

    2015-11-20

    The mechanism of flow in glassy materials is interrogated using mechanical spectroscopy applied to model nearly hard sphere colloidal glasses during flow. Superimposing a small amplitude oscillatory motion orthogonal onto steady shear flow makes it possible to directly evaluate the effect of a steady state flow on the out-of-cage (α) relaxation as well as the in-cage motions. To this end, the crossover frequency deduced from the viscoelastic spectra is used as a direct measure of the inverse microstructural relaxation time, during flow. The latter is found to scale linearly with the rate of deformation. The microscopic mechanism of flow can then be identified as a convective cage release. Further insights are provided when the viscoelastic spectra at different shear rates are shifted to scale the alpha relaxation and produce a strain rate-orthogonal frequency superposition, the colloidal analogue of time temperature superposition in polymers with the flow strength playing the role of temperature. Whereas the scaling works well for the α relaxation, deviations are observed both at low and high frequencies. Brownian dynamics simulations point to the origins of these deviations; at high frequencies these are due to the deformation of the cages which slows down the short-time diffusion, while at low frequency, deviations are most probably caused by some mild hydroclustering. PMID:26636876

  14. Stabilizing a 22 karat nanogolden cage

    Science.gov (United States)

    Wang, Q.; Sun, Q.; Jena, P.

    2009-11-01

    Since the discovery of C60 fullerene, considerable efforts have been devoted to find other elements with similar hollow cage structures. However, search for hollow metallic cages with a diameter similar to that of C60 fullerene has been elusive. We describe a procedure for the rational design of metallic cages by suitably choosing their size, composition, and charge state. A 22 karat nanogolden cage with a diameter of about 8.5 Å and consisting of 12 Al and 20 Au atoms is found to be metastable, which can be stabilized by embedding a Mn4 cluster. In contrast to bulk Mn, which is antiferromagnetic, and isolated Mn4 cluster, which is ferromagnetic with a giant magnetic moment of 20μB, the Mn4@Al12Au20 endohedral complex exhibits magnetic bistability with 0μB and 14μB configurations being energetically nearly degenerate. These results, based on density functional theory, open the door to design a novel class of endohedral complexes with possible applications.

  15. 50 CFR 648.75 - Cage identification.

    Science.gov (United States)

    2010-10-01

    ... are issued, or if rendered null and void in accordance with 15 CFR part 904. (d) Return. Tags that... Wildlife and Fisheries FISHERY CONSERVATION AND MANAGEMENT, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION... Clam and Ocean Quahog Fisheries § 648.75 Cage identification. Except as provided in § 648.76,...

  16. An Easy Synthesis of Two Cage Hydrocarbons.

    Science.gov (United States)

    Dong, Dao Cong

    1982-01-01

    Describes a simple, three-step synthesis of two cage molecules, birdcage hydrocarbon (VIII) and its homologue, the homobirdcage hydrocarbon IX. Indicates that all products are easily purified and formed in high yields in this activity suitable for advanced undergraduate laboratory courses. (Author/JN)

  17. Structural and dynamical properties of Yukawa balls

    International Nuclear Information System (INIS)

    To study the structural and dynamical properties of finite 3D dust clouds (Yukawa balls) new diagnostic tools have been developed. This contribution describes the progress towards 3D diagnostics for measuring the particle positions. It is shown that these diagnostics are capable of investigating the structural and dynamical properties of Yukawa balls and gaining insight into their basic construction principles

  18. Fusion characteristics of ball lighting like configurations

    International Nuclear Information System (INIS)

    Assuming that an already proposed self-organization physical scenario is at the origin of both ball lightnings as well as fireballs produced in high intensity electrical discharges, we suggest a new possibility to create fusion relevant ball lightning like configurations in laboratory. Perhaps this becomes possible by prolonging in a controllable way their lifetime and energy content. (author)

  19. Phenomenon of ball lightning and its outgrowths

    International Nuclear Information System (INIS)

    New physical phenomena deduced from properties of ball lightning are considered under assumption that ball lightning is a light bubble comprising of a thin spherical layer of compressed air where an intense light circulates in all possible directions. Explanation of behavior of autonomous luminous objects produced at gas discharge is presented

  20. Are perytons signatures of ball lighting?

    CERN Document Server

    Dodin, I Y

    2014-01-01

    The enigmatic downchirped signals, called "perytons", that are detected by radio telescopes in the GHz frequency range may be produced by an atmospheric phenomenon known as ball lightning. Although this is still a hypothesis, the parallels between perytons and ball lightning are striking.

  1. Some Mathematics and Physics of Ball Games.

    Science.gov (United States)

    Hughes, D. E.

    1985-01-01

    Gives examples on the applications of arithmetic, geometry, and some calculus, vector algebra, and mechanics to ball games. Suggestions for further interesting investigations are provided together with references to other articles and books on applications of mathematics and physics to ball games and sports in general. (JN)

  2. Decomposition of balls in R^d

    OpenAIRE

    Kiss, Gergely; Somlai, Gabor

    2016-01-01

    We investigate the decomposition problem of balls into finitely many congruent pieces in dimension d = 2k. In addition, we prove that the d dimensional unit ball B_d can be divided into finitely many congruent pieces if d = 4 or d ≥ 6. We show that the minimal number of required pieces is less than 20d if d ≥ 10.

  3. Coefficient of Restitution of a Tennis Ball

    Directory of Open Access Journals (Sweden)

    Andre Roux

    2007-06-01

    Full Text Available The coefficient of restitution (COR of a tennis ball was investigated over a range of impact velocities. It was found that the COR of the ball was lower than ATP regulations specify, and that the COR decreased with increasing impact velocity.

  4. Coefficient of Restitution of a Tennis Ball

    OpenAIRE

    Andre Roux; Jennifer Dickerson

    2007-01-01

    The coefficient of restitution (COR) of a tennis ball was investigated over a range of impact velocities. It was found that the COR of the ball was lower than ATP regulations specify, and that the COR decreased with increasing impact velocity.

  5. Flicker Ball, Physical Education: 5551.34.

    Science.gov (United States)

    Stout, Paul L.

    This course outline is a guide for teaching skills of flicker ball in grades 7-12. The course format includes lectures, game situations, class tournaments, and tests that focus on mastery of skills, understanding of rules, and development of techniques in shooting and passing. Course content includes the following: (a) history of flicker ball, (b)…

  6. Soccer Ball Lift Coefficients via Trajectory Analysis

    Science.gov (United States)

    Goff, John Eric; Carre, Matt J.

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin…

  7. A direct bonded fixed partial dental prosthesis: a clinical report.

    Science.gov (United States)

    Tanoue, Naomi; Tanaka, Takuo

    2015-01-01

    A direct bonded fixed partial dental prosthesis, with a composite resin denture tooth as a pontic, a tri-n-butylborane initiated adhesive resin, and screw posts for reinforcement, was still functioning after an observation period of 20 years. The prosthesis was found to be reliable for long-term clinical use when chemically and mechanically reinforced. PMID:25277033

  8. Results of Heart Valve Replacement with the SORIN Prosthesis

    OpenAIRE

    Colombo, Tiziano; Donatelli, Francesco; Quaini, Eugenio; Vitali, Ettore; Pellegrini, Alessandro

    1987-01-01

    From March 1977 to December 1981, 872 patients at our institution underwent valve replacement with a pyrolytic carbon tilting disc prosthesis manufactured in Italy by SORIN-Biomedica. To verify the performance characteristics of this prosthesis, we analyzed the intermediate-term results obtained over a cumulative total of 3,041 patient-years (pt-yr) of follow-up.

  9. Magnet-Retained Facial Prosthesis Combined with Maxillary Obturator

    OpenAIRE

    Mahnaz Hatami; Hamid Badrian; Siamak Samanipoor; Marcelo Coelho Goiato

    2013-01-01

    Prosthetic rehabilitation of the midfacial defects has always perplexed prosthodontists. These defects lead to functional and esthetic deficiencies. The purpose of this clinical case report was the presentation of the prosthetic rehabilitation of an extraoral-intraoral defect using two-piece prosthesis magnetically connected. This prosthesis has dramatically improved the patient’s speech, mastication, swallowing, and esthetic.

  10. Placement of prosthesis after total maxillectomy in edentulous patient

    OpenAIRE

    Sinha, Vikas; Bhowate, R. R.; Raizada, R. M.; Jain, S. K. T.; N.Chaturvedi, V.

    1999-01-01

    It is very difficult to retain the prosthesis in edentulous patient after total maxillectomy as there are no teeth on the opposite side around which clasp can be applied, however if holes are drilled in obturator and in alveolar ridge and wire is passed through it, prosthesis can be retained satisfactorily.

  11. A direct bonded fixed partial dental prosthesis: A clinical report

    OpenAIRE

    Tanoue, Naomi; Tanaka, Takuo

    2015-01-01

    A direct bonded fixed partial dental prosthesis, with a composite resin denture tooth as a pontic, a tri-n-butylborane initiated adhesive resin, and screw posts for reinforcement, was still functioning after an observation period of 20 years. The prosthesis was found to be reliable for long-term clinical use when chemically and mechanically reinforced.

  12. Use of Jonas Silicon-Silver prosthesis in erectile impotence.

    OpenAIRE

    Rowe, P H; Royle, M. G.

    1983-01-01

    Eleven patients presenting over the last three years with erectile impotence who have been treated by the insertion of the Jonas Silicon-Silver penile prosthesis are reviewed. The insertion of this prosthesis is a minor procedure. It has a simple design, low cost, no permanent erection or mechanical problems and an excellent cosmetic and functional result.

  13. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis (interpositional implant) is a device that is intended to be an interface between the natural articulating...

  14. A model for ball lightning

    International Nuclear Information System (INIS)

    A model for ball lightning (BL) is described. It is based upon the vorton model for elementary particles, which exploits the symmetry between electricity and magnetism. The core, or driving engine, of BL in this model is comprised of a vorton-antivorton plasma. The energy of BL, which derives from nucleon decay catalyzed by this plasma, leads, through various mechanisms, to BL luminosity as well as to other BL features. It is argued that this model could also be a suitable explanation for other luminous phenomena, such as the unidentified atmospheric light phenomena seen at Hessdalen. It is predicted that BL and similar atmospheric luminous phenomena should manifest certain features unique to this model, which would be observable with suitable instrumentation

  15. La balle et la plume

    Directory of Open Access Journals (Sweden)

    Peter Marquis

    2012-06-01

    Full Text Available Fin octobre 2008, la nouvelle fit l’effet d’une bombe : Barack Obama, alors candidat à la présidence américaine, demanda à la chaîne câblée Fox News de retarder le début du sixième match de la World Series de base-ball afin de diffuser un spot de campagne. Son adversaire, John McCain, soutenu par le camp républicain et une partie de la population, monta aussitôt au créneau pour dénoncer l’hérésie : s’arroger le droit de perturber cette grande finale du championnat au déroulement immuable reve...

  16. Penile Corporeal Reconstruction during Difficult Placement of a Penile Prosthesis

    Directory of Open Access Journals (Sweden)

    Viet Q. Tran

    2008-01-01

    Full Text Available For some patients with impotence and concomitant severe tunical/corporeal tissue fibrosis, insertion of a penile prosthesis is the only option to restore erectile function. Closing the tunica over an inflatable penile prosthesis in these patients can be challenging. We review our previous study which included 15 patients with severe corporeal or tunical fibrosis who underwent corporeal reconstruction with autologous rectus fascia to allow placement of an inflatable penile prosthesis. At a mean follow-up of 18 months (range 12 to 64, all patients had a prosthesis that was functioning properly without evidence of separation, herniation, or erosion of the graft. Sexual activity resumed at a mean time of 9 weeks (range 8 to 10. There were no adverse events related to the graft or its harvest. Use of rectus fascia graft for coverage of a tunical defect during a difficult penile prosthesis placement is surgically feasible, safe, and efficacious.

  17. Difficult factors in Management of Impacted Dental Prosthesis in Esophagus

    Directory of Open Access Journals (Sweden)

    Efiaty A. Soepardi

    2005-03-01

    Full Text Available A dental prosthesis which ingested and impacted in esophagus, is an emergency case and life threatening, so require immediate esophagoscopy intervention for removing. The objective of this study is to assess some factors can caused dtfficulties in diagnosing and treating the ingested and impacted dental prosthesis in the esophagus and their complications. This retrospective study analyzed patient’s chart whose underwent esophagoscopy for removing the impacted dental prosthesis in Dr. Cipto Mangunkusumo General Hospital, Jakarta, Indonesia during a period between January 1997 and December 2003. Neck-chest X-ray and esophagoscopy were performed in all patients to identify the existence of the dental prosthesis as a diagnostic and treatment procedure. The length of time for removing the dental prosthesis was recorded and stated as a less difficult esophagoscopy when it takes time less than 60 minutes and as a difficult  esophagoscopy takes 60 minutes or longer. Some risk difficulties factors were statistically analyzed. There were 53 patients of ingested dental prosthesis in esophagus. Only 51 cases were analyzed According to the length of time for removing the dental prosthesis by esophagoscopy, 22 patients were recorded as less difficult cases and 29 patients as difficult cases. Two cases among the cases needed cervicotomy after unsuccessful esophagoscopy removal. The difficulties to diagnose an impacted dental prosthesis in the esophagus caused by unreliable clinical history, unclear signs and symptoms, unable to be detected by X-ray and was not found during esophagoscopy. The difficulties in treating due to mucosal laceration, edema, bleeding, failure of the first extraction and conformity with the size and shape, the wire outside the dental prosthesis and the length of time stayed in the esophagus. (Med J Indones 2005; 14: 33-6Keywords: ingested dental prosthesis, radioluscent foreign body, length of time of esophagoscopy

  18. The Nijdam voice prosthesis : A self-retaining valveless voice prosthesis for vocal rehabilitation after total laryngectomy

    NARCIS (Netherlands)

    van den Hoogen, Frank J. A.; Nijdam, Hoite F.; Veenstra, Aalze; Manni, JJ

    1996-01-01

    Voice prosthesis-assisted speech rehabilitation after total laryngectomy has proven to be successful in the majority of patients and exceeds the results of traditional oesophageal speech. Nevertheless 10-30% failure rates are still reported. In part this is due to prosthesis-related problems, in par

  19. Site development interim removable dental prosthesis.

    Science.gov (United States)

    Pasquinelli, Kirk L; Sze, Alexander J; Matosian, Alex J

    2016-07-01

    Transitioning a patient with partial edentulism through hard and soft tissue grafting to an implant restoration with an interim removable dental prosthesis (IRDP) presents a challenge to the restorative dentist. The management of grafted sites requires care, and without the appropriate design, an IRDP may impede surgical outcomes and place the graft at risk for displacement or necrosis. A site development IRDP (SDIRDP) for a grafted site must fulfill restorative goals and promote the surgical objectives for site development. A technique is described for fabricating an SDIRDP that facilitates surgical procedures and maintains prosthetic goals. PMID:26831920

  20. Poor fixation of the Mittelmeier hip prosthesis

    International Nuclear Information System (INIS)

    We have evaluated 30 Mittelmeier hips on an average 3.3 years after the operation. Seven hips had been revised because of severe pain and mechanical loosening and one because of fracture of the threaded ceramic cup. Only five of the remaining 22 hips were asymptomatic. There was radiographic migration of the acetabular and femoral components in more than one third of the hips and increased scintimetric values around the femoral component in all but two hips. Unfavorable design of the Mittelmeier prosthesis may be an important etiologic factor contributing to poor component fixation and inferior clinical results. (author)

  1. Malfunctioned and Fractured Penile Prosthesis Caused by Cross Placement: Case Report

    Directory of Open Access Journals (Sweden)

    Nihat Karakoyunlu

    2015-05-01

    Full Text Available Penile prosthesis is a functional option for patients who have erectile dysfunction after failed medical and intracavernosal treatments. Malleable penile prosthesis is a good alternative. Penile prosthesis implantation is a surgical process. Seldomly complications occur. In this study we presented a 61 y old man who has malfunctioned and broken penile prosthesis due to cross implantation.

  2. Malfunctioned and Fractured Penile Prosthesis Caused by Cross Placement: Case Report

    OpenAIRE

    Nihat Karakoyunlu; Sercan Sarı; Harun Ozdemir; Hikmet Topaloglu; Ugur Ozok; Levent Sagnak; Hamit Ersoy

    2015-01-01

    Penile prosthesis is a functional option for patients who have erectile dysfunction after failed medical and intracavernosal treatments. Malleable penile prosthesis is a good alternative. Penile prosthesis implantation is a surgical process. Seldomly complications occur. In this study we presented a 61 y old man who has malfunctioned and broken penile prosthesis due to cross implantation.

  3. Viscoelastic modelling of tennis ball properties

    International Nuclear Information System (INIS)

    An explicit finite element (FE) tennis ball model which illustrates the effects of the viscoelastic materials of a tennis ball on ball deformation and bounce during normal impacts is presented. A tennis ball is composed of a rubber core and a fabric cover comprised of a wool-nylon mix which exhibit non-linear strain rate properties during high velocity impacts. The rubber core model was developed and validated using low strain rate tensile tests on rubber samples as well as high velocity normal impacts of pressurised cores at velocities ranging from 15 m/s to 50 m/s. The impacts were recorded using a high speed video (HSV) camera to determine deformation, impact time and coefficient of restitution (COR). The material properties of the core model were tuned to match the HSV results. A two component anisotropic fabric model was created which included artificial Rayleigh damping to account for hysteresis effects, and the core model 'tuning' process was used to refine the cloth layer. The ball model's parameters were in good agreement with experimental data at all velocities for both cores and complete balls, and a time sequenced comparison of HSV ball motion and FE model confirmed the validity of the model.

  4. BALL - biochemical algorithms library 1.3

    Directory of Open Access Journals (Sweden)

    Stöckel Daniel

    2010-10-01

    Full Text Available Abstract Background The Biochemical Algorithms Library (BALL is a comprehensive rapid application development framework for structural bioinformatics. It provides an extensive C++ class library of data structures and algorithms for molecular modeling and structural bioinformatics. Using BALL as a programming toolbox does not only allow to greatly reduce application development times but also helps in ensuring stability and correctness by avoiding the error-prone reimplementation of complex algorithms and replacing them with calls into the library that has been well-tested by a large number of developers. In the ten years since its original publication, BALL has seen a substantial increase in functionality and numerous other improvements. Results Here, we discuss BALL's current functionality and highlight the key additions and improvements: support for additional file formats, molecular edit-functionality, new molecular mechanics force fields, novel energy minimization techniques, docking algorithms, and support for cheminformatics. Conclusions BALL is available for all major operating systems, including Linux, Windows, and MacOS X. It is available free of charge under the Lesser GNU Public License (LPGL. Parts of the code are distributed under the GNU Public License (GPL. BALL is available as source code and binary packages from the project web site at http://www.ball-project.org. Recently, it has been accepted into the debian project; integration into further distributions is currently pursued.

  5. Numerical simulation of ball-racket impact

    Science.gov (United States)

    Yu, Yingpang

    The collision of a ball with a tennis racket is usually modeled in terms of rigid body dynamics or an elastic system involving only a few springs. In this paper, we study the impact between a tennis ball and racket, by modeling the tennis ball in two different yaws. One method models the tennis ball as a Hertz elastic body and the other one models the ball by a more accurate finite element analysis. In the first model, we assume that the elastic properties of the ball obeys Hertz's law. In the finite element model, we consider the tennis ball as a shell witch is a elastic system constructed out of many isotropic small linear flat, elements, witch have both elastic and damping properties. The damping in each way is approximated as viscous term. In both methods, we study the static condition of deformation against a rigid surface before applying these models to dynamical processes. We compare these two methods and eventually determine how the racket parameters effect the performance of the racket, using numerical simulations. Comparison with experiment are show to confirm the general conclusion of the model.

  6. Gravitational Waves from Q-ball Formation

    CERN Document Server

    Chiba, Takeshi; Yamaguchi, Masahide

    2009-01-01

    We study the detectability of the gravitational waves (GWs) from the Q-ball formation associated with the Affleck-Dine (AD) mechanism, taking into account both of the dilution effect due to Q-ball domination and of finite temperature effects. The AD mechanism predicts the formation of non-topological solitons, Q-balls, from which GWs are generated. Q-balls with large conserved charge $Q$ can produce a large amount of GWs. On the other hand, the decay rate of such Q-balls is so small that they may dominate the energy density of the universe, which implies that GWs are significantly diluted and that their frequencies are redshifted during Q-ball dominated era. Thus, the detectability of the GWs associated with the formation of Q-balls is determined by these two competing effects. We find that there is a finite but small parameter region where such GWs may be detected by future detectors such as DECIGO or BBO, only in the case when the thermal logarithmic potential dominates the potential of the AD field. Otherw...

  7. Viscoelastic modelling of tennis ball properties

    Science.gov (United States)

    Sissler, L.; Jones, R.; Leaney, P. G.; Harland, A.

    2010-06-01

    An explicit finite element (FE) tennis ball model which illustrates the effects of the viscoelastic materials of a tennis ball on ball deformation and bounce during normal impacts is presented. A tennis ball is composed of a rubber core and a fabric cover comprised of a wool-nylon mix which exhibit non-linear strain rate properties during high velocity impacts. The rubber core model was developed and validated using low strain rate tensile tests on rubber samples as well as high velocity normal impacts of pressurised cores at velocities ranging from 15 m/s to 50 m/s. The impacts were recorded using a high speed video (HSV) camera to determine deformation, impact time and coefficient of restitution (COR). The material properties of the core model were tuned to match the HSV results. A two component anisotropic fabric model was created which included artificial Rayleigh damping to account for hysteresis effects, and the core model 'tuning' process was used to refine the cloth layer. The ball model's parameters were in good agreement with experimental data at all velocities for both cores and complete balls, and a time sequenced comparison of HSV ball motion and FE model confirmed the validity of the model.

  8. Craniofacial reconstruction using rational cubic ball curves.

    Directory of Open Access Journals (Sweden)

    Abdul Majeed

    Full Text Available This paper proposes the reconstruction of craniofacial fracture using rational cubic Ball curve. The idea of choosing Ball curve is based on its robustness of computing efficiency over Bezier curve. The main steps are conversion of Digital Imaging and Communications in Medicine (Dicom images to binary images, boundary extraction and corner point detection, Ball curve fitting with genetic algorithm and final solution conversion to Dicom format. The last section illustrates a real case of craniofacial reconstruction using the proposed method which clearly indicates the applicability of this method. A Graphical User Interface (GUI has also been developed for practical application.

  9. Cohesion in ball lightning and cook plasmas

    International Nuclear Information System (INIS)

    The phenomenon of ball lightning has been observed for a long time, but the nature of these luminous balls has been unknown. It is proposed here that they consist of highly excited Rydberg atoms with large polarizabilities. Thus the cohesion of the balls comes from photon exchange forces (London dispersion forces) rather than electron exchange (chemical) forces. The cohesion in plasmas generated at the back faces of detonating explosives (Cook's plasmas) may have a similar basis. Numerical estimates are given to justify these interpretations

  10. Rotating Boson Stars and Q-Balls

    CERN Document Server

    Kleihaus, B; List, M; Kleihaus, Burkhard; Kunz, Jutta; List, Meike

    2005-01-01

    We consider axially symmetric, rotating boson stars. Their flat space limits represent spinning Q-balls. We discuss their properties and determine their domain of existence. Q-balls and boson stars are stationary solutions and exist only in a limited frequency range. The coupling to gravity gives rise to a spiral-like frequency dependence of the boson stars. We address the flat space limit and the limit of strong gravitational coupling. For comparison we also determine the properties of spherically symmetric Q-balls and boson stars.

  11. Porous Organic Cages for Sulfur Hexafluoride Separation.

    Science.gov (United States)

    Hasell, Tom; Miklitz, Marcin; Stephenson, Andrew; Little, Marc A; Chong, Samantha Y; Clowes, Rob; Chen, Linjiang; Holden, Daniel; Tribello, Gareth A; Jelfs, Kim E; Cooper, Andrew I

    2016-02-10

    A series of porous organic cages is examined for the selective adsorption of sulfur hexafluoride (SF6) over nitrogen. Despite lacking any metal sites, a porous cage, CC3, shows the highest SF6/N2 selectivity reported for any material at ambient temperature and pressure, which translates to real separations in a gas breakthrough column. The SF6 uptake of these materials is considerably higher than would be expected from the static pore structures. The location of SF6 within these materials is elucidated by X-ray crystallography, and it is shown that cooperative diffusion and structural rearrangements in these molecular crystals can rationalize their superior SF6/N2 selectivity. PMID:26757885

  12. Cathodic Cage Plasma Nitriding: An Innovative Technique

    OpenAIRE

    de Sousa, R. R. M.; de Araújo, F. O.; da Costa, J. A. P.; A. de S. Brandim; de Brito, R. A.; Alves, C

    2012-01-01

    Cylindrical samples of AISI 1020, AISI 316, and AISI 420 steels, with different heights, were simultaneously treated by a new technique of ionic nitriding, entitled cathodic cage plasma nitriding (CCPN), in order to evaluate the efficiency of this technique to produce nitrided layers with better properties compared with those obtained using conventional ionic nitriding technique. This method is able to eliminate the edge effect in the samples, promoting a better uniformity of temperature, and...

  13. Titanium mesh cages (TMC) in spine surgery

    OpenAIRE

    Grob, Dieter; Daehn, Sylvia; Mannion, Anne F.

    2004-01-01

    The introduction of the titanium mesh cage (TMC) in spinal surgery has opened up a variety of applications that are realizable as a result of the versatility of the implant. Differing applications of TMCs in the whole spine are described in a series of 150 patients. Replacement and reinforcement of the anterior column represent the classic use of cylindrical TMCs. The TMC as a multisegmental concave support in kyphotic deformities and as a posterior interlaminar spacer or lamina replacement a...

  14. Trace element kinetics in caged Mytilus galloprovincialis

    OpenAIRE

    Richir, Jonathan; Lepoint, Gilles; Donnay, Annick; Gobert, Sylvie

    2014-01-01

    Trace elements (TEs) remain contaminants of concern because of their persistence, ability to concentrate in organisms and toxicity. The Mediterranean mussel Mytilus galloprovincialis Lamarck, 1819 is a relevant bioindicator of TE coastal contamination. However, little research has studied the combined influence of environmental condition changes and physiological processes on their kinetics in that species. Caged M. galloprovincialis were thus immerged in 2 contrasted pristine Corsican (Franc...

  15. Biomechanische Untersuchungen von LWS-Cages

    OpenAIRE

    Gottwald, Maria

    2004-01-01

    Fragestellung: Cages sind Implantate, die der Fusionierung von Wirbelkörpern dienen. Zu ihren wichtigsten biomechanischen Eigenschaften gehört die Gewährleistung einer hohen Stabilität unmittelbar nach Implantation - der Primärstabilität -, die Aufrechterhaltung dieser Stabilität auch nach wiederholten Belastungen - Langzeitstabilität - und eine geringe Sinterungsneigung, worunter man das eindringen der Implantate in die angrenzenden Wirbelkörper versteht. Ziel dieser Arbeit war es nun zwe...

  16. Shah's Indian penile prosthesis placement after phallic reconstruction with radial forearm flap

    OpenAIRE

    Patwardhan, Sujata K; Shah, Rupin; Kulkarni, Vijay; Varma, Radheshyam R.

    2008-01-01

    We report a successful implantation of Indian penile prosthesis after total phallic reconstruction. The differential stiffness of the Shah penile prosthesis is felt to have less potential for erosion, the most common complication of rigid prosthetic stiffening devices when used in a neo-phallus. This prosthesis is an alternative to the inflatable prosthesis in patients who choose a rigid prosthesis due to economical constraints.

  17. Dental prosthesis and buccal lesions in the elderly

    Directory of Open Access Journals (Sweden)

    Beatriz García Alpizar

    2010-02-01

    Full Text Available Fundament: Buccal lesions in the elderly are very frequent and they constitute a problem of health due to the consequences that cause. Objective: to describe the characteristics of the removable prosthesis used by the population of 60 and more years age and their relationship with the lesions of the oral mucosa. Methods: We carried out a study descriptive of cross section in 125 elderly with oral prosthesis. The characteristics of the removable prosthesis were described and their relationship with the lesions of the oral mucosa. The square chi tests and the analysis of relative risk were use to determine the association between the variables, also we used a logistical regression model to determine the independent relationship of each factor with the presence of the lesions. Results: We was a 12% of the people with stomatitis sub prosthesis, 8% presented lesions growth hyperplasic and 5,6% they were have angular queilitis. The lesions in the oral mucosa increased in people with prosthesis in not well state, bad hygiene this and in the female sex. Conclusion: the chronic lesions were the more prevalence in this study and they were very related with factors like: state of the conservation the prosthesis, time use, hygiene this and sex of the individual; but when determining the independent influence from each factor with the presence lesions, we established that only the state of conservation of the prosthesis and their hygiene affected of the important way to the old men of this study.

  18. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  19. Disposition of plutonium with HTGRs using Pu burner balls and Th breeder balls

    International Nuclear Information System (INIS)

    A concept of reactor system was developed with which weapons-grade Plutonium could be made perfectly worthless in use for weapons. It is a pebble bed type HTGR using Pu burner ball fuels and Th breeder ball fuels. The residual amounts of 239Pu in spent Pu balls become less than 1% of the initial loading. The power coefficient was made negative by reducing the parasitic neutron absorption reaction rate of 135Xe. (author)

  20. Staging quantum cryptography with chocolate balls

    OpenAIRE

    Svozil, Karl

    2005-01-01

    Moderated by a director, laymen and students are encouraged to assume the role of quanta and enact a quantum cryptographic protocol. The performance is based on a generalized urn model capable of reproducing complementarity even for classical chocolate balls.

  1. Staging quantum cryptography with chocolate balls

    CERN Document Server

    Svozil, K

    2006-01-01

    Moderated by a director, laymen and students are encouraged to assume the role of quanta and enact a quantum cryptographic protocol. The performance is based on a generalized urn model capable of reproducing complementarity even for classical chocolate balls.

  2. Static Load Distribution in Ball Bearings

    Science.gov (United States)

    Ricci, Mario

    2010-01-01

    A numerical procedure for computing the internal loading distribution in statically loaded, single-row, angular-contact ball bearings when subjected to a known combined radial and thrust load is presented. The combined radial and thrust load must be applied in order to avoid tilting between inner and outer rings. The numerical procedure requires the iterative solution of Z + 2 simultaneous nonlinear equations - where Z is the number of the balls - to yield an exact solution for axial and radial deflections, and contact angles. Numerical results for a 218 angular-contact ball bearing have been compared with those from the literature and show significant differences in the magnitudes of the ball loads, contact angles, and the extent of the loading zone.

  3. On the formation of ball lightning

    International Nuclear Information System (INIS)

    A plasma continuum model for the formation of ball lightning is developed based on a substantial number of reports that the ball is often in the discharge column of a previous lightning stroke. The usual method of setting up the plasma equation for a one-component electron plasma is used. An approximate equation for the plasma is derived from the describing equation which is then solved exactly in terms of the Jacobi elliptic functions. The formation of the ball is based on a nonlinearity of the plasma equation which uner certain circumstances permits the field to collapse into a small region. This collapse is interpreted to be ball lightning. The approximate equation derived for the plasma has the same form as a previous equation used to describe the formation of the fireball plasma. (author)

  4. Aerodynamic drag of modern soccer balls

    OpenAIRE

    Asai, Takeshi; Seo, Kazuya

    2013-01-01

    Soccer balls such as the Adidas Roteiro that have been used in soccer tournaments thus far had 32 pentagonal and hexagonal panels. Recently, the Adidas Teamgeist II and Adidas Jabulani, respectively having 14 and 8 panels, have been used at tournaments; the aerodynamic characteristics of these balls have not yet been verified. Now, the Adidas Tango 12, having 32 panels, has been developed for use at tournaments; therefore, it is necessary to understand its aerodynamic characteristics. Through...

  5. Gravitational waves from Q-ball formation

    International Nuclear Information System (INIS)

    We study the detectability of the gravitational waves (GWs) from the Q-ball formation associated with the Affleck-Dine (AD) mechanism, taking into account both the dilution effects due to Q-ball domination and to finite temperature. The AD mechanism predicts the formation of nontopological solitons, Q-balls, from which GWs are generated. Q-balls with large conserved charge Q can produce a large amount of GWs. On the other hand, the decay rate of such Q-balls is so small that they may dominate the energy density of the Universe, which implies that GWs are significantly diluted and that their frequencies are redshifted during the Q-ball dominated era. Thus, the detectability of the GWs associated with the formation of Q-balls is determined by these two competing effects. We find that there is a finite but small parameter region where such GWs may be detected by future detectors such as DECIGO or BBO, only in the case when the thermal logarithmic potential dominates the potential of the AD field. Otherwise GWs from Q-balls would not be detectable even by these futuristic detectors: ΩGW0-21. Unfortunately, for such parameter region the present baryon asymmetry of the Universe can hardly be explained unless one fine-tunes A-terms in the potential. However the detection of such a GW background may give us an information about the early Universe, for example, it may suggest that the flat directions with B-L=0 are favored.

  6. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    International Nuclear Information System (INIS)

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  7. The bionic eye (electronic visual prosthesis): a review.

    Science.gov (United States)

    Suaning, G J; Lovell, N H; Schindhelm, K; Coroneo, M T

    1998-08-01

    The concept of a visual prosthesis for the blind or partially sighted is not a new one. Indeed, for more than three decades this technology based treatment for blindness has appeared imminent. Despite the concerted efforts of numerous physicians, scientists and engineers, the successful application of a useful visual prosthesis remains elusive. The present review will endeavour to describe past efforts, investigate the present state of the art and indicate the obstacles that must be overcome in order to bring an electronic visual prosthesis to fruition. PMID:9717748

  8. A modified technique for retention of orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sameera R Shaikh

    2011-01-01

    Full Text Available An orbital defect (congenital or acquired causes severe facial asymmetry and disfigurement, which results in psychological and social disturbances to the patient. It becomes a challenging task for a maxillofacial prosthodontist to fabricate a prosthesis that replicates the healthy side of the face. Success of the prosthesis depends primarily on satisfactory retention of the same. This clinical report illustrates rehabilitation of a patient with an orbital defect by fabricating a hollow orbital prosthesis, utilizing anatomical undercuts for retention using an acrylic resin template relined by a resilient denture liner.

  9. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk.

    Science.gov (United States)

    Wang, Song; Wang, Fei; Liao, Zhenhua; Wang, Qingliang; Liu, Yuhong; Liu, Weiqiang

    2015-10-01

    A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in

  10. Heated-Pressure-Ball Monopropellant Rocket Engine

    Science.gov (United States)

    Greene, William D.

    2005-01-01

    A recent technology disclosure presents a concept for a monopropellant thermal spacecraft thruster that would feature both the simplicity of a typical prior pressure-fed propellant supply system and the smaller mass and relative compactness of a typical prior pump-fed system. The source of heat for this thruster would likely be a nuclear- fission reactor. The propellant would be a cryogenic fluid (a liquefied low-molecular-weight gas) stored in a tank at a low pressure. The propellant would flow from the tank, through a feedline, into three thick-walled spherical tanks, denoted pressure balls, that would be thermally connected to the reactor. Valves upstream and downstream of the pressure balls would be operated in a three-phase cycle in which propellant would flow into one pressure ball while the fluid underwent pressurization through heating in another ball and pressurized propellant was discharged from the remaining ball into the reactor. After flowing through the reactor, wherein it would be further heated, the propellant would be discharged through an exhaust nozzle to generate thrust. A fraction of the pressurized gas from the pressure balls would be diverted to maintain the desired pressure in the tank.

  11. A novel eccentric lapping machine for finishing advanced ceramic balls

    OpenAIRE

    Kang, J.; Hadfield, M.

    2001-01-01

    Advanced ceramic balls are used extensively in hybrid precision ball bearings and show advantages in high speed, high temperature, high load and hostile environment. Finishing these balls with high quality, good efficiency and low cost is critical to their widespread application. A brief review of the methods for finishing ceramic balls is presented. The design of a novel eccentric lapping machine for finishing advanced ceramic balls is described. The kinematics of eccentric lapping is analys...

  12. The effect of pesticide residue on caged mosquito bioassays.

    Science.gov (United States)

    Barber, J A S; Greer, Mike; Coughlin, Jamie

    2006-09-01

    Wind tunnel experiments showed that secondary pickup of insecticide residue by mosquitoes in cage bioassays had a significant effect on mortality. Cage bioassays using adult Ochlerotatus taeniorhynchus (Wiedemann) investigated the effect of exposure time to a contaminated surface. Cages were dosed in a wind tunnel using the LC50 for naled (0.124 mg a.i./ml) and an LC25 (0.0772 mg a.i./ml) for naled. Half of the bioassay mosquitoes were moved directly into clean cages with the other half remaining in the sprayed, hence contaminated, cage. Treatment mortality was assessed at 8, 15, 30, 60, 120, 240, and 1,440 min postapplication. Cage contamination had a significant effect on mosquito mortality for both the LC25 and LC50 between 15 and 30 min postapplication. PMID:17067048

  13. Secret of a ball lightning

    OpenAIRE

    E.V. Savich

    2013-01-01

    Шаровая молния – явление природы, происходящее при ударе линейной молнии с ее воздействием тепловой и магнитной энергии, возникающей вокруг канала линейной молнии и в результате образующей из окружающего воздуха облако пара, переходящего под воздействием магнитного поля сегнетоэлектрическое состояние. A ball lightning is a natural phenomenon that occurs at a streak lightning stroke with its action by thermal and magnetic energy releasing around the streak lightning channel and transforming...

  14. A secure and economical system for caging venomous snakes

    OpenAIRE

    Powell, R. L.

    2003-01-01

    This paper describes an inexpensive and secure cage system for housing venomous snakes. The cages are easily constructed from commercially available plastic containers and are lightweight and can be stacked, minimizing the area needed to house numerous animals. They allow easy access to the animal and can be adequately disinfected. These cages can be individually locked and also allow for full viewing of the animal.

  15. PROBLEMS OF BIOFOULING ON FISH–CAGE NETS IN AQUACULTURE

    OpenAIRE

    Merica Slišković; Gorana Jelić

    2002-01-01

    Biofouling on fish–cage netting is a serious technical and economical problem to aquaculture worldwide. Compensation for the effects of biofouling must be included in cage system design and planning, as fouling can dramatically increase both weight and drag. Settlements of sessile plants and animals, with accumulation of the detritus diminish the size of mesh and can rapidly occlude mesh. Negative effect of smaller mesh size is changing in water flow trough the cages. Biofouling problems nece...

  16. THE PROCEDURE AND THE CRITERIA FOR FISH CAGES ALLOCATION

    OpenAIRE

    Valentina Andrić; Gordana Jelić Mrčelić; Merica Slišković; Ivana Miletić

    2010-01-01

    In the Republic of Croatia, fish cage farming is one of the most important economic activities. Fish cage farms inevitably influence the quality of marine environment. Environment protection measures are established in order to minimize negative effects on the stability of ecosystem. The aim of this paper is to give an overview on the procedure of fish cage farm allocation, environment protection measures, as also as program of monitoring before, during and after fish farming allocation.

  17. THE PROCEDURE AND THE CRITERIA FOR FISH CAGES ALLOCATION

    Directory of Open Access Journals (Sweden)

    Valentina Andrić

    2010-10-01

    Full Text Available In the Republic of Croatia, fish cage farming is one of the most important economic activities. Fish cage farms inevitably influence the quality of marine environment. Environment protection measures are established in order to minimize negative effects on the stability of ecosystem. The aim of this paper is to give an overview on the procedure of fish cage farm allocation, environment protection measures, as also as program of monitoring before, during and after fish farming allocation.

  18. Sex therapy for the penile prosthesis recipient.

    Science.gov (United States)

    Schover, L R

    1989-02-01

    In conclusion, the evidence for technical success of the penile prosthesis is clear, but more detailed follow-up studies suggest that a large minority of patients and partners fail to achieve sexual satisfaction. If the goal of surgery is to restore sexual frequency, variety, and pleasure to optimal levels, an integrated treatment program that incorporates sex therapy may be more successful than implantation alone. The type of sex therapy required depends on the risk factors present for postsurgery sexual dissatisfaction. A majority of patients can benefit from several sessions of brief sexual counseling preoperatively, with routine follow-up at 3 and 6 months after surgery to identify problems in resuming sex successfully. I also would point out that an integrated treatment approach is just as applicable to home intracavernosal injection programs. Including sex therapy in the package might reduce the large drop-out rates currently being seen and might decrease the risk of misuse of these medications. PMID:2916282

  19. Metabolics of stair ascent with a powered transfemoral prosthesis.

    Science.gov (United States)

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics. PMID:26737489

  20. Failed total carpometacarpal joint prosthesis of the thumb

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Homilius, Morten

    2010-01-01

    Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis. The...... male:female ratio was 1:4 and the mean duration of observation 32 months (range 6-52). In three patients the revised implant was a MOJE uncemented carpometacarpal joint prosthesis and in seven patients an Elektra uncemented one. At follow-up grip strength was reduced to less than 90% of the other hand...... in eight of 10 patients, but the mean Disabilities of the arm, shoulder, and hand (DASH) scores, self-reported pinch-grip-related function, and pain were comparable with our earlier published results with the Elektra carpometacarpal total joint prosthesis....

  1. Retinal Prosthesis: A Potential Benefit for the Blind

    Institute of Scientific and Technical Information of China (English)

    YANG Xiao-jie

    2009-01-01

    Retinal degenerative diseases may induce the degeneration of outer retina and in turn, blindness. Nevertheless, due to the maintenance of inner retina, the coding and processing of visual neurons responses are still able to be executed naturally. Therefore,an effective retinal prosthesis device may be developed by mimicking the function of outer retina: transferring the visual light into artificial stimulus and delivering the stimulus to the retina aiming to evoke the neural responses. As two main developing directions for current retinal prosthesis,epiretinal (ER) and subretinal (SR) prosthesis are both undergoing experimental stage and possessing advantages and limitations. Further investigations in power supply, biocompatibility, etc.are still required. Additionally, suprachoroidal transretinal stimulation (STS) and neurotransmitter-induced stimulation as some other alternatives in retinal prosthesis are also considered as promising research directions, although they are not mature enough to be applied commercially, either.

  2. Effect of a ball skill intervention on children's ball skills and cognitive functions

    NARCIS (Netherlands)

    Westendorp-Haverdings, Marieke; Houwen, Suzanne; Hartman, Esther; Mombarg, Remo; Smith, Joanne; Visscher, Chris

    2014-01-01

    Purpose: This study examined the effect of a 16-wk ball skill intervention on the ball skills, executive functioning (in terms of problem solving and cognitive flexibility), and in how far improved executive functioning leads to improved reading and mathematics performance of children with learning

  3. Aerodynamic drag of modern soccer balls.

    Science.gov (United States)

    Asai, Takeshi; Seo, Kazuya

    2013-12-01

    Soccer balls such as the Adidas Roteiro that have been used in soccer tournaments thus far had 32 pentagonal and hexagonal panels. Recently, the Adidas Teamgeist II and Adidas Jabulani, respectively having 14 and 8 panels, have been used at tournaments; the aerodynamic characteristics of these balls have not yet been verified. Now, the Adidas Tango 12, having 32 panels, has been developed for use at tournaments; therefore, it is necessary to understand its aerodynamic characteristics. Through a wind tunnel test and ball trajectory simulations, this study shows that the aerodynamic resistance of the new 32-panel soccer ball is larger in the high-speed region and lower in the middle-speed region than that of the previous 14- and 8-panel balls. The critical Reynolds number of the Roteiro, Teamgeist II, Jabulani, and Tango 12 was ~2.2 × 10(5) (drag coefficient, C d  ≈ 0.12), ~2.8 × 10(5) (C d  ≈ 0.13), ~3.3 × 10(5) (C d  ≈ 0.13), and ~2.4 × 10(5) (C d  ≈ 0.15), respectively. The flight trajectory simulation suggested that the Tango 12, one of the newest soccer balls, has less air resistance in the medium-speed region than the Jabulani and can thus easily acquire large initial velocity in this region. It is considered that the critical Reynolds number of a soccer ball, as considered within the scope of this experiment, depends on the extended total distance of the panel bonds rather than the small designs on the panel surfaces. PMID:23705104

  4. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    OpenAIRE

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided...

  5. Ethical issues in the development of a vestibular prosthesis

    OpenAIRE

    Poppendieck, Wigand; Hoffmann, Klaus-Peter; Merfeld, Daniel; Guyot, Jean-Philippe; Micera, Silvestro

    2011-01-01

    During the development of a neural prosthesis, various ethical aspects have to be considered. These range from the basic design of the prosthesis and manufacturing of the various components and the system using biocompatible materials to extensive in vitro and in vivo testing and investigations in the animal model, before taking the final step and going to human trials. As medical systems, neural prostheses have to be proven absolutely safe before considering any clinical study. In this work,...

  6. Nasal Prosthesis Rehabilitation after Partial Rhinectomy: A Clinical Report

    OpenAIRE

    Seçilmiş, Aslı; Öztürk, A. Nilgün

    2007-01-01

    Facial defects resulting from neoplasms, congenital malformations, or trauma can be restorated with facial prostheses using different materials and retention methods to achieve a lifelike look and function. For the successful result, a lot of factors as harmony, texture, color matching, and blending of tissue interface of prosthesis is important. This clinical report describes treatment using a silicone prosthesis with a mechanical - retentined design for a patient who received a partial rhin...

  7. Mastication Improvement After Partial Implant-supported Prosthesis Use

    OpenAIRE

    Gonçalves, T.M.S.V.; Campos, C.H.; Gonçalves, G.M.; Moraes, M; Rodrigues Garcia, R.C.M.

    2013-01-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor...

  8. Treatment Using Functionally Fixed Prosthesis: A Case Report

    OpenAIRE

    Chandra, Sumi; Singh, Ajay; Gupta, Himanshu; Chandra, Chetan

    2013-01-01

    Most dental practitioners as well as their patients prefer to have fixed rather than removable prosthesis. However, there are many clinical situations that prohibit the use of the fixed treatment modality. These clinical cases can vary from, simply not having the proper number of healthy teeth and/or implants to, the esthetically challenging cases of high smile lines and severe loss of alveolar support. The approach of using a traditional removable prosthesis in these situations has always be...

  9. Improving esthetics of finger prosthesis by glove silicone

    OpenAIRE

    Laxman Singh Kaira; Esha Dabral

    2014-01-01

    Finger and partial finger amputations are some of the most frequently encountered forms of partial hand loss. A high quality esthetic prosthesis with passive function can be helpful to the patient since loss or congenital absence or malformation have both a social and psychological impact on the patient. Prosthetics is an art and science, which provides lifelike appearance to the lost structures of the patient. This case report presents the fabrication of a silicone finger prosthesis, which h...

  10. The specialty of bucomaxillofacial prosthesis and its performance in Dentistry

    OpenAIRE

    Fabiano Geronasso SIMÕES; Ricardo Cesar dos REIS; Reinaldo Brito e Dias

    2009-01-01

    Introduction:The human attempt to restore the bucomaxillofacialregion by heteroplasia is as old as the formation of civilizations. Archaeological excavations have revealed Egyptian mummies with artificial eyes, nose and ears.Objective and literature review:The aim of this study was to report the evolution and importance of bucomaxillofacial prosthesis,which might be the greatest challenge ofdental surgeons within the specialties of Dentistry.Conclusion: Thebucomaxillofacial prosthesis outreac...

  11. Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

    OpenAIRE

    Faramarzi, Mohammad; Jahangiri, Reza; Roosta, Sareh

    2016-01-01

    Introduction: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, we decided to perform a study encompassing this issue. Materials and Methods: 105 patients, who were ...

  12. TOTAL ANKLE ARTHROPLASTY: BRAZILIAN EXPERIENCE WITH THE HINTEGRA PROSTHESIS

    OpenAIRE

    Nery, Caio; Fernandes, Túlio Diniz; Réssio, Cibele; Fuchs, Mauro Luiz; Godoy Santos, Alexandre Leme de; Ortiz, Rafael Trevisan

    2015-01-01

    Ankle arthrosis is becoming more and more common. The search for solutions that preserve joint function has led to a new generation of prosthesis with three components and more degrees of freedom. This paper presents the results achieved for ten patients treated with the HINTEGRA Prosthesis (Integra, New Deal), through collaborative action between the Foot and Ankle Groups of the Orthopedics and Traumatology divisions of Escola Paulista de Medicina, Unifesp, and the School of Medicine of the ...

  13. Post Reconstruction Breast Pyoderma Gangrenosum: Early Recognition and Prosthesis Salvage

    OpenAIRE

    Cicuto, Bryan; Cheriyan, Thomas; Rudnicki, Pamela; Guo, Lifei

    2015-01-01

    Summary: We report 3 cases of breast pyoderma gangrenosum in patients undergoing total mastectomy with immediate reconstruction. All three received systemic corticosteroid treatment, resulting in resolution of symptoms. As experience grew, early diagnosis in the third patient helped prosthesis salvage and timely return to the original course of reconstruction. This represents the first report of prosthesis salvage from post breast reconstruction pyoderma gangrenosum, and it demonstrates that ...

  14. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Institute of Scientific and Technical Information of China (English)

    Zhi-Xin Zhao; Liang Wen; Tie-Bing Qu; Li-Li Hou; Dong Xiang; Jia Bin

    2015-01-01

    Background:The goal of total knee arthroplasty (TKA) is to restore knee kinematics.Knee prosthesis design plays a very important role in successful restoration.Here,kinematics models of normal and prosthetic knees were created and validated using previously published data.Methods:Computed tomography and magnetic resonance imaging scans of a healthy,anticorrosive female cadaver were used to establish a model of the entire lower limbs,including the femur,tibia,patella,fibula,distal femur cartilage,and medial and lateral menisci,as well as the anterior cruciate,posterior cruciate,medial collateral,and lateral collateral ligaments.The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis,which was then validated by comparison with a previous study.The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion.Results:Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study,suggesting that this model can be used for further analyses.The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient,or insufficiently aggressive,"rollback" compared with the lateral femur of the normal knee.In addition,a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis.Conclusions:There were still several differences between the kinematics of the PS knee prosthesis and a normal knee,suggesting room for improving the design of the PS knee prosthesis.The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  15. Literature Review on Needs of Upper Limb Prosthesis Users

    OpenAIRE

    Cordella, Francesca; Ciancio, Anna Lisa; Sacchetti, Rinaldo; Davalli, Angelo; Cutti, Andrea Giovanni; Guglielmelli, Eugenio; Zollo, Loredana

    2016-01-01

    The loss of one hand can significantly affect the level of autonomy and the capability of performing daily living, working and social activities. The current prosthetic solutions contribute in a poor way to overcome these problems due to limitations in the interfaces adopted for controlling the prosthesis and to the lack of force or tactile feedback, thus limiting hand grasp capabilities. This paper presents a literature review on needs analysis of upper limb prosthesis users, and points out ...

  16. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Directory of Open Access Journals (Sweden)

    Zhi-Xin Zhao

    2015-01-01

    Full Text Available Background: The goal of total knee arthroplasty (TKA is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Results: Both the output data trends and the measured values derived from the normal knee′s kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  17. Visual prosthesis wireless energy transfer system optimal modeling

    OpenAIRE

    Li, Xueping; Yang, Yuan; Gao, Yong

    2014-01-01

    Background Wireless energy transfer system is an effective way to solve the visual prosthesis energy supply problems, theoretical modeling of the system is the prerequisite to do optimal energy transfer system design. Methods On the basis of the ideal model of the wireless energy transfer system, according to visual prosthesis application condition, the system modeling is optimized. During the optimal modeling, taking planar spiral coils as the coupling devices between energy transmitter and ...

  18. Clinical and functional outcomes of the saddle prosthesis

    OpenAIRE

    Donati, D.; D’Apote, G.; M. Boschi; Cevolani, L.; M.G. Benedetti

    2012-01-01

    Background The implantation of a saddle prosthesis after resection of a pelvic tumor has been proposed as a simple method of reconstruction that provides good stability and reduces the surgical time, thus limits the onset of intraoperative complications. There are no studies in the literature of patients evaluated using gait analysis after being implanted with a saddle prosthesis. The present study is a retrospective case review aimed at illustrating long-term clinical and functional findings...

  19. Preliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis

    OpenAIRE

    Sup, Frank; Varol, Huseyin Atakan; Mitchell, Jason; Withrow, Thomas J.; Goldfarb, Michael

    2009-01-01

    This paper presents a self-contained powered knee and ankle prosthesis, intended to enhance the mobility of transfemoral amputees. A finite-state based impedance control approach, previously developed by the authors, is used for the control of the prosthesis during walking and standing. Experiments on an amputee subject for level treadmill and overground walking are described. Knee and ankle joint angle, torque, and power data taken during walking experiments at various speeds demonstrate the...

  20. Advanced behavioural screening: automated home cage ethology.

    Science.gov (United States)

    Spruijt, Berry M; DeVisser, Leonie

    2006-01-01

    Animal behaviour has been studied using two approaches, (1) well-controlled experiments focusing on specific responses and (2) those with natural - fuzzy - but biologically relevant conditions. Ideally, one behavioural test should be able to address both. The home cage provided with various stimuli is proposed as an all-in-one possibility. This, however, results in an exponential increase in complexity regarding observation and analysis tools. It seems difficult to accept that behavioural expressions need a mathematical approach to unravel its organisation and meaning. Developments in artificial intelligence and data mining are essential to accelerate this necessary evolution in behavioural sciences.: PMID:24980412

  1. Design and Optimization of Sinusoidal Formed Femur Prosthesis

    Directory of Open Access Journals (Sweden)

    Ahmet Zafer ŞENALP

    2015-01-01

    Full Text Available One of the major problems in hip replacement surgery is the hip replacement loosening. Hip replacement loosening occurs over time after the surgery and it is related to the discretization between the bone cement and prosthesis. The underlying factors of this situation are the stress occurring in the bone cement and the shape of the prosthesis. In this study, cortical and trabecular layers of the femur, bone cement and prosthesis were modeled. The models of bone cement and prosthesis were constructed parametrically and two different sinusoidal formed prostheses were developed unlike the former prostheses shapes. Analyses were conducted for these two different sinusoidal forms by using finite element method and optimization was conducted to obtain the appropriate prosthesis stem shape and bone cement thickness by using parametric modeling in finite element analyses. For finite element analyses and optimization, Ansys Workbench software was used and analyses were conducted for 316LS stainless steel material. Finally, the optimum prosthesis stem shape and bone cement thickness was determined by using the results of the analyses in the first stage

  2. Ball Machine Usage in Tennis: Movement Initiation and Swing Timing While Returning Balls from a Ball Machine and from a Real Server

    Science.gov (United States)

    Carboch, Jan; Süss, Vladimir; Kocib, Tomas

    2014-01-01

    Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server). Receivers’ movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing. Key points Players have shorter initial move time when they are facing the ball machine. Using the ball machine results in different swing timing and movement coordination. The use of the ball machine should be limited. PMID:24790483

  3. Flight trajectory of a rotating golf ball with grooves

    Science.gov (United States)

    Baek, Moonheum; Kim, Jooha; Choi, Haecheon

    2014-11-01

    Dimples are known to reduce drag on a sphere by the amount of 50% as compared to a smooth surface. Despite the advantage of reducing drag, dimples deteriorate the putting accuracy owing to their sharp edges. To minimize this putting error but maintain the same flight distance, we have devised a grooved golf ball (called G ball hereafter) for several years. In this study, we modify the shape and pattern of grooves, and investigate the flow characteristics of the G ball by performing wind-tunnel experiments at the Reynolds numbers of 0 . 5 ×105 - 2 . 5 ×105 and the spin ratios (ratio of surface velocity to the free-stream velocity) of 0 - 0.6 that include the real golf-ball velocity and rotational speed. We measure the drag and lift forces on the rotating G ball and compare them with those of a smooth ball and two well-known dimpled balls. The lift-to-drag ratio of the G ball is much higher than that of a smooth ball and is in between those of the two dimpled balls. The trajectories of flying golf balls are computed. The flight distance of G ball is almost the same as that of one dimpled ball but slightly shorter than that of the other dimpled ball. The fluid-dynamic aspects of these differences will be discussed at the talk. Supported by 2011-0028032, 2014M3C1B1033980.

  4. Dark matter balls help supernovae to explode

    Science.gov (United States)

    Froggatt, C. D.; Nielsen, H. B.

    2015-10-01

    As a solution to the well-known problem that the shock wave potentially responsible for the explosion of a supernova actually tends to stall, we propose a new energy source arising from our model for dark matter. Our earlier model proposed that dark matter should consist of cm-large white dwarf-like objects kept together by a skin separating two different sorts of vacua. These dark matter balls or pearls will collect in the middle of any star throughout its lifetime. At some stage during the development of a supernova, the balls will begin to take in neutrons and then other surrounding material. By passing into a ball nucleons fall through a potential of order 10 MeV, causing a severe production of heat — of order 10 foe for a solar mass of material eaten by the balls. The temperature in the iron core will thereby be raised, splitting up the iron into smaller nuclei. This provides a mechanism for reviving the shock wave when it arrives and making the supernova explosion really occur. The onset of the heating due to the dark matter balls would at first stop the collapse of the supernova progenitor. This opens up the possibility of there being two collapses giving two neutrino outbursts, as apparently seen in the supernova SN1987A — one in Mont Blanc and one 4 h 43 min later in both IMB and Kamiokande.

  5. Stress analysis of different prosthesis materials in implant-supported fixed dental prosthesis using 3D finite element method

    OpenAIRE

    Pedram Iranmanesh; Alireza Abedian; Naeimeh Nasri; Ehsan Ghasemi; Saber Khazaei

    2014-01-01

    Introduction: In the present study, the finite element method (FEM) was used to investigate the effects of prosthesis material types on stress distribution of the bone surrounding implants and to evaluate stress distribution in three-unit implant-supported fixed dental prosthesis (FDP). Materials and Methods: A three-dimensional (3D) finite element FDP model of the maxillary second premolar to the second molar was designed. Three load conditions were statically applied on the functional cusps...

  6. Influence of metabolic cage on Wistar rat physiological state

    Directory of Open Access Journals (Sweden)

    Judita Zymantiene

    2016-03-01

    Full Text Available The aim of this study was to investigate the influence of metabolic cage housing on the Wistar rat physiological state and to analyze the correlation between the minerals in blood and urine. Thirty male rats were used in the experiment. Fifteen rats (control group were housed individually in standard polycarbonate cages and fifteen rats (experimental group in metabolic cages (Techniplast, Italy for two weeks. Body weight, respiration rate, water and food consumptions were recorded for each animal at the beginning of the experiment. The same parameters, as well as blood and urine parameters of control and experimental animals were recorded during the experiment after 72 h, 168 h and 336 h of housing in standard cages and metabolic cages. Urine collection was measured only in the experimental group. Rats weight decreased from 3.84 % to 18.59 % (P<0.05, respiration rate from 18.65 % to 24.59 % (P<0.05 when rats were housed in metabolic cages. Consumption of food and water by the rat depended on how long the animal was kept in metabolic cage. Glucose concentration increased on average by 15.37 %, WBC count decreased by 5.83 % in the blood of rats housed in metabolic cages compared to the animals housed in standard cages. We did not observe significant changes of triglycerides concentration, red blood cells count and total protein between all rats. The positive moderate correlation of rat housing in a metabolic cage was between K blood and K urine, P blood and P urine, Na blood and K blood, between Na urine and P urine and significant negative moderate correlation was determined between K urine and P urine. These present study findings indicate that metabolism cage housing significantly affects rat’s physiological parameters and potentially may influence animal health and well being.

  7. Computed tomography measurement of rib cage morphometry in emphysema.

    Directory of Open Access Journals (Sweden)

    Nicola Sverzellati

    Full Text Available BACKGROUND: Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers. METHODS: Rib cage diameters and areas (calculated from the inner surface of the rib cage in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT. CTs were analyzed with software, which allows quantification of total emphysema (emphysema%. The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models. RESULTS: A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1%, and forced vital capacity (FVC% fit best with the rib cage measurements (R(2 = 64% for the rib cage area variation at the lower anatomical level. Gender had the biggest impact on rib cage diameter and area (105.3 cm(2; 95% CI: 111.7 to 98.8 for male lower area. Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm(2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%. Lower rib cage areas decreased as FVC% decreased (5.1 cm(2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation. CONCLUSIONS: This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.

  8. Preinjector for Linac 1, Faraday cage

    CERN Multimedia

    1974-01-01

    The 50 MeV Linac 1 started up in 1958 as injector to the 26 GeV PS, with a 520 kV Cockcroft-Walton generator as its preinjector, housed in a vast Faraday cage, visible here. When the Cockcroft-Walton broke down in 1973, it was replaced by a much smaller SAMES generator, of the kind used for electrostatic separators. From 1980 on, Linac 2 took over as injector for the 800 MeV Booster, and Linac 1 continued as injector for LEAR. In 1984, the electrostatic preinjector (i.e. the Faraday cage with its contents, SAMES generator and all) was replaced by a 520 keV RFQ. At the lower left corner we see the HV connectors to the SAMES generator, at the right edge part of the opened electronics-platform. Jean-Luc Vallet sees to it that all parts are properly grounded. See also 7403073X, 7403074X, 7403081X, 7403083X.

  9. On the Ball-Constrained Weighted Maximin Dispersion Problem

    OpenAIRE

    Wang, Shu; Xia, Yong

    2016-01-01

    The ball-constrained weighted maximin dispersion problem $(\\rm P_{ball})$ is to find a point in an $n$-dimensional Euclidean ball such that the minimum of the weighted Euclidean distance from given $m$ points is maximized. We propose a new second-order cone programming relaxation for $(\\rm P_{ball})$. Under the condition $m\\le n$, $(\\rm P_{ball})$ is polynomial-time solvable since the new relaxation is shown to be tight. In general, we prove that $({\\rm P_{ball}})$ is NP-hard. Then, we propos...

  10. Algorithm on robot soccer pass and shoot a ball

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Introduces of robot soccer's competition software of Harbin Institute of Technology(HIT), the con cept of running range and the method of calculating the running range for both the opponent and our teammates according to the distances Between the ball and robot soccers, and therefore the method of calculating the angle that the robot passes or shoots the ball according to the running ranges of both sides. And gives the examples of passing the ball when the ball's position is in the backcourt and shooting the ball when the ball's position is in the frontcourt.

  11. Flaglets: Exact Wavelets on the Ball

    CERN Document Server

    Leistedt, Boris

    2013-01-01

    We summarise the construction of exact axisymmetric scale-discretised wavelets on the sphere and on the ball. The wavelet transform on the ball relies on a novel 3D harmonic transform called the Fourier-Laguerre transform which combines the spherical harmonic transform with damped Laguerre polynomials on the radial half-line. The resulting wavelets, called flaglets, extract scale-dependent, spatially localised features in three-dimensions while treating the tangential and radial structures separately. Both the Fourier-Laguerre and the flaglet transforms are theoretically exact thanks to a novel sampling theorem on the ball. Our implementation of these methods is publicly available and achieves floating-point accuracy when applied to band-limited signals.

  12. The bouncing ball through a geometrical series

    Science.gov (United States)

    Flores, Sergio; Alfaro, Luis L.; Chavez, Juan E.; Bastarrachea, Aztlan; Hurtado, Jazmin

    2008-10-01

    The mathematical representation of the physical situation related to a bouncing ball on the floor is an important understanding difficulty for most of the students during the introductory mechanics and mathematics courses. The research group named Physics and mathematics in context from the University of Ciudad Juarez is concerned about the versatility in the change from a mathematical representation to the own physical context of any problem under a traditional instruction. In this case, the main idea is the association of the physical properties of the bouncing ball situation to the nearest mathematical model based on a geometrical series. The proposal of the cognitive development is based on a geometrical series that shows the time the ball takes to stop. In addition, we show the behavior of the ratio of the consecutive heights during the motion.

  13. Relativistic-microwave theory of ball lightning.

    Science.gov (United States)

    Wu, H-C

    2016-01-01

    Ball lightning, a fireball sometimes observed during lightnings, has remained unexplained. Here we present a comprehensive theory for the phenomenon: At the tip of a lightning stroke reaching the ground, a relativistic electron bunch can be produced, which in turn excites intense microwave radiation. The latter ionizes the local air and the radiation pressure evacuates the resulting plasma, forming a spherical plasma bubble that stably traps the radiation. This mechanism is verified by particle simulations. The many known properties of ball lightning, such as the occurrence site, relation to the lightning channels, appearance in aircraft, its shape, size, sound, spark, spectrum, motion, as well as the resulting injuries and damages, are also explained. Our theory suggests that ball lighting can be created in the laboratory or triggered during thunderstorms. Our results should be useful for lightning protection and aviation safety, as well as stimulate research interest in the relativistic regime of microwave physics. PMID:27328835

  14. Electrostatic charge bounds for ball lightning models

    International Nuclear Information System (INIS)

    Several current theories concerning the nature of ball lightning predict a substantial electrostatic charge in order to account for its observed motion and shape (Turner 1998 Phys. Rep. 293 1; Abrahamson and Dinniss 2000 Nature 403 519). Using charged soap bubbles as a physical model for ball lightning, we show that the magnitude of charge predicted by some of these theories is too high to allow for the types of motion commonly observed in natural ball lightning, which includes horizontal motion above the ground and movement near grounded conductors. Experiments show that at charge levels of only 10-15 nC, 3-cm-diameter soap bubbles tend to be attracted by induced charges to the nearest grounded conductor and rupture. We conclude with a scaling rule that can be used to extrapolate these results to larger objects and surroundings

  15. Fire ball in LIB-ICF reactor

    International Nuclear Information System (INIS)

    In the design of LIB-ICF Reactor, it is the most impotant probrem to choose the cavity gas. In order to transport the light ion beam without a large collisional loss, the cavity gas density must be low enough. On the other hand, the fusion energy is transported by neutrons, X-ray and pellet deblis. The energy of X-ray and pellet debris is absorbed in the cavity gas and then fire ball is generated. The propagation of fire ball and the load to the cavity wall are varied with the density, temperature, components and mixture-rate of the gas. In the case of liquid-wall reactor, it should be mixed with the cavity gas. In this study, the behavior of fire ball is investigated by using the computer code FIRE, so that the components of the cavity gas and other parameters are determined. (author)

  16. From Schwinger Balls to Black Holes

    CERN Document Server

    Allahbakhshi, Davood

    2016-01-01

    We have shown intriguing similarities between Schwinger balls and black holes. By considering black hole as a gravitational Schwinger ball, we have derived the Bekenstein-Hawking entropy and the first law of black hole thermodynamics as a direct result of the inverse area dependence of the gravitational force. It is also shown that the Planck length is nothing but the gravitational Schwinger length. The relation between the mass and the radius of the black hole is derived by considering the black hole as a Schwinger ball of gravitons. We show how the evolution of the entanglement entropy of the black hole, as Page introduced many years ago, can be obtained by including gravitons in the black hole's evaporation process and using a deformed EPR mechanism. Also this deformed EPR mechanism can solve the information paradox. We show how naive simultaneous usage of Page's argument and equivalence principle leads to firewall problem.

  17. Drag Crisis of Gyro-Balls

    Science.gov (United States)

    Yokoyama, Yoshiyuki; Miyazaki, Takeshi; Himeno, Ryutaro

    2007-11-01

    Using a high-speed video camera, we measured the trajectory and the rotation of a hard baseball thrown by a pitching machine which can launch Gyro-Balls (rifle spinning balls). We determined the drag- and lift- coefficients by analyzing the video images. The measurements were performed in the range of 0.6x10^5ball with SP=0.12,0.23 and 0.35, decreases gradually with Re. However, the drag coefficient of a 2-seam gyro-ball with SP=0.12 decreases in two steps, i.e. in the ranges 0.8x10^5Ball with SP=0.23,0.35 are almost constant below Re=1.6x10^5 and Re=1.3x10^5, respectively. Their minima are attained at Re=1.8x10^5 and Re=1.6x10^5, respectively. These findings confirm the occurrence of the drag crisis for Gyro-Balls. The different Re-dependencies are due to the different seam patterns.

  18. Morphosynthesis of cubic silver cages on monolithic activated carbon.

    Science.gov (United States)

    Wang, Fei; Zhao, Hong; Lai, Yijian; Liu, Siyu; Zhao, Binyuan; Ning, Yuesheng; Hu, Xiaobin

    2013-11-14

    Cubic silver cages were prepared on monolithic activated carbon (MAC) pre-absorbed with Cl(-), SO4(2-), or PO4(3-) anions. Silver insoluble salts served as templates for the morphosynthesis of silver cages. The silver ions were reduced by reductive functional groups on MAC micropores through a galvanic cell reaction mechanism. PMID:24080952

  19. 48 CFR 204.7202-1 - CAGE codes.

    Science.gov (United States)

    2010-10-01

    ...)(1) If a prospective contractor located in the United States must register in the Central Contractor... registrants must obtain a North Atlantic Treaty Organization CAGE (NCAGE) code in order to register in the CCR... dial-up capability; or (D) The Internet to access the CAGE Lookup Server at...

  20. Design of the UHVDC Corona Cage in China

    Institute of Scientific and Technical Information of China (English)

    GUO Jian; LU Jiayu; ZHANG Wenliang

    2013-01-01

    For the purpose of testing and analysing the corona characteristics of UHVDC bundle conductors,UHVDC corona cage would be built in China.Corona cage is one of the indispensable equipments for conductor corona performance researches.Tests of conductor cotona characteristics in corona cages can overcome the shortages of those with test lines.The dimensions of several corona cages constructed overseas were introduced in this paper.Based on foreign experiences and the requirement of State Grid Corporation of China,the UHVDC corona cage was designed as double-cage,double-layer,three-seetions,and catenary shape with the size of 70 m×22 m× 13 m.The corona loss measurement system,radio interference measuring system,and the audible noise measuring system are also detailed,including the measurement theory,connection with the cage,the parameters and the designing basis.The UHVDC corona cage has been put into service.It now undergoes a large amount of audible noise and radio frequency interference tests.

  1. Abnormal Behavior in Relation to Cage Size in Rhesus Monkeys

    Science.gov (United States)

    Paulk, H. H.; And Others

    1977-01-01

    Examines the effects of cage size on stereotyped and normal locomotion and on other abnormal behaviors in singly caged animals, whether observed abnormal behaviors tend to co-occur, and if the development of an abnormal behavior repertoire leads to reduction in the number of normal behavior categories. (Author/RK)

  2. Polymers containing borane or carborane cage compounds and related applications

    Science.gov (United States)

    Bowen, III, Daniel E.; Eastwood, Eric A.

    2012-06-05

    Polymers comprising residues of borane and/or carborane cage compound monomers having at least one polyalkoxy silyl substituent. Such polymers can further comprise one or more reactive matrices and/or co-monomers covalently bound with the cage compound monomer residues. Methods of making and applications for using such polymers are also disclosed.

  3. Ammonia Levels and Urine-Spot Characteristics as Cage-Change Indicators for High-Density Individually Ventilated Mouse Cages.

    Science.gov (United States)

    Washington, Ida M; Payton, Mark E

    2016-01-01

    Mouse cage and bedding changes are potentially stressful to mice and are also labor- and resource-intensive. These changes are often performed on a calendar-based schedule to maintain a clean microenvironment and limit the concentrations of ammonia to which mice and workers are exposed. The current study sought to establish a performance-based approach to mouse cage-changing that uses urine spot characteristics as visual indicators of intracage ammonia levels. Colorimetric ammonia indicators were used to measure ammonia levels in individually-ventilated cages (IVC) housing male or female mice (n =5 per cage) of various strains at 1 to 16 d after cage change. Urine spot characteristics were correlated with ammonia levels to create a visual indicator of the cage-change criterion of 25 ppm ammonia. Results demonstrated a consistent increase in ammonia levels with days since cage change, with cages reaching the cage-change criterion at approximately 10 d for IVC containing male mice and 16 d for those with female mice. Ammonia levels were higher for male than female mice but were not correlated with mouse age. However, urine spot diameter, color, and edge characteristics were strongly correlated with ammonia levels. Husbandry practices based on using urine spot characteristics as indicators of ammonia levels led to fewer weekly cage changes and concomitant savings in labor and resources. Therefore, urine spot characteristics can be used as visual indicators of intracage ammonia levels for use of a performance (urine spot)-based approach to cage-changing frequency that maintains animal health and wellbeing. PMID:27177558

  4. Q-balls in Underground Experiments

    CERN Document Server

    Ouchrif, M

    2000-01-01

    In this paper we present some features of Q-balls and we discuss theirinteractions with matter, and their energy losses in the Earth, for a largerange of velocities. These calculations are used to compute the fractionalgeometrical acceptance of the MACRO detector. Furthermore a systematic analysisof the energy losses of Q-balls in three types of detectors is investigated.More specifically we have computed the light yield in liquid scintillators, theionization in streamer tubes and the Restricted Energy Loss in the CR39 nucleartrack detectors.

  5. Soccer ball lift coefficients via trajectory analysis

    Energy Technology Data Exchange (ETDEWEB)

    Goff, John Eric [Department of Physics, Lynchburg College, Lynchburg, VA 24501 (United States); Carre, Matt J, E-mail: goff@lynchburg.ed [Department of Mechanical Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2010-07-15

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin parameters that have not been obtained by today's wind tunnels. Our trajectory analysis technique is not only a valuable tool for professional sports scientists, it is also accessible to students with a background in undergraduate-level classical mechanics.

  6. Automated estimation of hip prosthesis migration: a feasibility study

    Science.gov (United States)

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  7. Reasonable Ball Size of Ball Mill for Preparing Coal Water Fuel and Forecasting Productive Capacity

    Institute of Scientific and Technical Information of China (English)

    张荣曾; 刘炯天; 徐志强; 郑明

    2002-01-01

    By using the matrix theory, a 5-parameter grinding mathema tical model is established. Based on the properties of feed coal and requirement s for size distribution of final product, the model gives the required grinding probability for various particles and corresponding ball size distribution. By u sing this model, 3 different sizes of ball mill are designed and put into commer cial use for coal water fuel. The forecasted ball mill capacity, the particle si zes and particle size distribution as well as the coal water fuel quality parame ters are all in line with industrial operation results, which have proved the su itability of the model.

  8. Intraoral framework pick-up technique to improve fit of a metal-resin implant prosthesis

    Directory of Open Access Journals (Sweden)

    Mirza Rustum Baig

    2012-01-01

    Full Text Available The achievement of passive fit is an important prerequisite for the prevention of complications in full-arch screw-retained implant prosthesis. With cemented prosthesis, the cementation compensates for the discrepancies in the cast framework, but the lack of retrievability seems undesirable. The aim of this paper is to propose a modified screw-retained prosthesis design for complete arch implant fixed rehabilitation. A technique for the fabrication of a full-arch metal-resin implant-supported screw-retained prosthesis is described. Cementation of the framework to the abutments intraorally improves the passivity of fit of the prosthesis on the implants. Maintenance of screw-access channels in the final prosthesis ensures retrievability. The metal-resin design allows for easy repair and maintenance. The prosthesis is cost-effective compared to conventional options and can be employed as a viable treatment alternative when considering metal-acrylic resin complete arch fixed prosthesis.

  9. Electrofriction method of manufacturing squirrel cage rotors

    Science.gov (United States)

    Hsu, John S.

    2005-04-12

    A method of making a squirrel cage rotor of copper material for use in AC or DC motors, includes forming a core with longitudinal slots, inserting bars of conductive material in the slots, with ends extending out of opposite ends of the core, and joining the end rings to the bars, wherein the conductive material of either the end rings or the bars is copper. Various methods of joining the end rings to the bars are disclosed including electrofriction welding, current pulse welding and brazing, transient liquid phase joining and casting. Pressure is also applied to the end rings to improve contact and reduce areas of small or uneven contact between the bar ends and the end rings. Rotors made with such methods are also disclosed.

  10. Protein Cages as Containers for Gold Nanoparticles.

    Science.gov (United States)

    Liu, Aijie; Verwegen, Martijn; de Ruiter, Mark V; Maassen, Stan J; Traulsen, Christoph H-H; Cornelissen, Jeroen J L M

    2016-07-01

    Abundant and highly diverse, viruses offer new scaffolds in nanotechnology for the encapsulation, organization, or even synthesis of novel materials. In this work the coat protein of the cowpea chlorotic mottle virus (CCMV) is used to encapsulate gold nanoparticles with different sizes and stabilizing ligands yielding stable particles in buffered solutions at neutral pH. The sizes of the virus-like particles correspond to T = 1, 2, and 3 Caspar-Klug icosahedral triangulation numbers. We developed a simple one-step process enabling the encapsulation of commercially available gold nanoparticles without prior modification with up to 97% efficiency. The encapsulation efficiency is further increased using bis-p-(sufonatophenyl)phenyl phosphine surfactants up to 99%. Our work provides a simplified procedure for the preparation of metallic particles stabilized in CCMV protein cages. The presented results are expected to enable the preparation of a variety of similar virus-based colloids for current focus areas. PMID:27135176

  11. Cathodic Cage Plasma Nitriding: An Innovative Technique

    Directory of Open Access Journals (Sweden)

    R. R. M. de Sousa

    2012-01-01

    Full Text Available Cylindrical samples of AISI 1020, AISI 316, and AISI 420 steels, with different heights, were simultaneously treated by a new technique of ionic nitriding, entitled cathodic cage plasma nitriding (CCPN, in order to evaluate the efficiency of this technique to produce nitrided layers with better properties compared with those obtained using conventional ionic nitriding technique. This method is able to eliminate the edge effect in the samples, promoting a better uniformity of temperature, and consequently, a smaller variation of the thickness/height relation can be obtained. The compound layers were characterized by X-ray diffraction, optical microscopy, and microhardness test profile. The results were compared with the properties of samples obtained with the conventional nitriding, for the three steel types. It was verified that samples treated by CCPN process presented, at the same temperature, a better uniformity in the thickness and absence of the edge effect.

  12. Transcription regulatory networks analysis using CAGE

    KAUST Repository

    Tegnér, Jesper N.

    2009-10-01

    Mapping out cellular networks in general and transcriptional networks in particular has proved to be a bottle-neck hampering our understanding of biological processes. Integrative approaches fusing computational and experimental technologies for decoding transcriptional networks at a high level of resolution is therefore of uttermost importance. Yet, this is challenging since the control of gene expression in eukaryotes is a complex multi-level process influenced by several epigenetic factors and the fine interplay between regulatory proteins and the promoter structure governing the combinatorial regulation of gene expression. In this chapter we review how the CAGE data can be integrated with other measurements such as expression, physical interactions and computational prediction of regulatory motifs, which together can provide a genome-wide picture of eukaryotic transcriptional regulatory networks at a new level of resolution. © 2010 by Pan Stanford Publishing Pte. Ltd. All rights reserved.

  13. Metabolic Prosthesis for Oxygenation of Ischemic Tissue

    Energy Technology Data Exchange (ETDEWEB)

    Greenbaum, Elias [ORNL

    2009-01-01

    This communication discloses new ideas and preliminary results on the development of a "metabolic prosthesis" for local oxygenation of ischemic tissue under physiological neutral conditions. We report for the first time the selective electrolysis of physiological saline by repetitively pulsed charge-limited electrolysis for the production of oxygen and suppression of free chlorine. For example, using 800 A amplitude current pulses and <200 sec pulse durations, we demonstrated prompt oxygen production and delayed chlorine production at the surface of a shiny 0.85 mm diameter spherical platinum electrode. The data, interpreted in terms of the ionic structure of the electric double layer, suggest a strategy for in situ production of metabolic oxygen via a new class of "smart" prosthetic implants for dealing with ischemic disease such as diabetic retinopathy. We also present data indicating that drift of the local pH of the oxygenated environment can be held constant using a feedback-controlled three electrode electrolysis system that chooses anode and cathode pair based on pH data provided by local microsensors. The work is discussed in the context of diabetic retinopathy since surgical techniques for multielectrode prosthetic implants aimed at retinal degenerative diseases have been developed.

  14. Detecting supersymmetric Q-balls with neutron stars

    OpenAIRE

    Madsen, Jes

    1998-01-01

    Supersymmetric Q-balls trapped in neutron stars or white dwarfs may cause the stars to explode. Trapping of Q-balls in neutron stars is shown to be less likely, but trapping in neutron star progenitors more likely than hitherto assumed, making neutron stars very sensitive Q-ball "detectors". White dwarfs only trap potentially dangerous Q-balls in a narrow parameter range.

  15. Rehabilitation of orbital defect with silicone orbital prosthesis retained by dental implants

    OpenAIRE

    Satyabodh Shesharaj Guttal; Jhanvi Desai; Adarsh Kudva; Patil, Basavaraj R.

    2016-01-01

    Orbital defects can result from cancer, birth anomalies, or trauma leading to an onslaught of problems in the function and psyche of the patient. These defects are restored by surgical reconstruction and followed by placement of orbital prosthesis for cosmetic makeup. The use of dental implants in retaining orbital prosthesis improves patient acceptance of the prosthesis owing to better retention and stability than conventional adhesive retained prosthesis. This case report describes a custom...

  16. An Alternative Approach to Combine Orbital Prosthesis and Obturator: A Case Report

    OpenAIRE

    Soganci, Gokce; Yalug, Suat; Kocacikli, Mustafa

    2011-01-01

    This report describes a different approach for diminishing the movements of orbital prosthesis during mimic movements and chewing function. Mechanical devices such as magnets are used to enhance the retention in case lack of the implants. However rigid fixation of obturator and orbital prosthesis can result in movements of the orbital prosthesis during mastication. In this case obturator and orbital prosthesis are combined by magnets. However this combination is not rigid because of an active...

  17. Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report

    OpenAIRE

    Sadid-Zadeh, Ramtin; Liu, Perng-Ru; Aponte-Wesson, Ruth; O'Neal, Sandra J

    2013-01-01

    This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a monolithic zirconia generated by CAD/CAM system on eight osseointegrated implants. The prosthesis was copy milled from an interim prosthesis minimizing occlusal adjustments on the definitive prosthesis at the time of delivery. Monolithic zirconia provides high esthetics and reduces the number of metal alloys used in the oral cavity.

  18. Fracture of Both Rods of a Malleable Penile Prosthesis: A Case Report

    OpenAIRE

    Berat Ozgur

    2013-01-01

    Only a few cases with mechanical failure has been reported with the malleable penile prosthesis. A 66 year old man, using the AMS 650® (American Medical Systems, Minnesota) malleable penile prosthesis for five years, was admitted with complaining a difficulty in sexual intercourse in the last weeks. Preoperative radiology and surgical exploration demonstrated a fracture in both rods. The malfunctioning penile prosthesis was removed, and a new AMS 650® malleable penile prosthesis was i...

  19. Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

    OpenAIRE

    Luis M Astudillo; Orlando Santana; Urbandt, Pablo A.; Benjo, Alexandre M.; Lior U Elkayam; Nascimento, Francisco O.; Lamas, Gervasio A.; Joseph Lamelas

    2012-01-01

    OBJECTIVE: We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD: We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of >0.85 cm2/m, 0.85-0.6...

  20. Isolated pump erosion of an inflatable penile prosthesis through the scrotum in a diabetic patient

    OpenAIRE

    Raidh A. Talib; Ahmad Shamsodini; Salem, Emad A.; Onder Canguven; Abdulla Al Ansari

    2013-01-01

    Isolated pump erosion is a rare complication in patients with inflatable penile prosthesis. We describe a case of a diabetic patient who underwent inflatable penile prosthesis implantation with subsequent isolated pump erosion. Repeated attempts of conservative repair of the erosion failed. Finally, the inflatable penile prosthesis was replaced with a malleable one to avoid new pump erosion. In case of isolated pump erosion, replacement of the inflatable penile prosthesis with a malleable one...

  1. Self-Contained Powered Knee and Ankle Prosthesis: Initial Evaluation on a Transfemoral Amputee

    OpenAIRE

    Sup, Frank; Varol, Huseyin Atakan; Mitchell, Jason; Withrow, Thomas J.; Goldfarb, Michael

    2009-01-01

    This paper presents an overview of the design and control of a fully self-contained prosthesis, which is intended to improve the mobility of transfemoral amputees. A finite-state based impedance control approach, previously developed by the authors, is used for the control of the prosthesis during walking and standing. The prosthesis was tested on an unilateral amputee subject for over-ground walking. Prosthesis sensor data (joint angles and torques) acquired during level ground walking exper...

  2. Holomorphic Spaces in the Unit Ball of

    Directory of Open Access Journals (Sweden)

    Augusto Guadalupe Miss Paredes

    2013-01-01

    Full Text Available We introduce the and vector spaces of holomorphic functions defined in the unit ball of , generalizing previous work like Ouyang et al. (1998, Stroethoff (1989, and Choa et al. (1992. Likewise, we characterize those spaces in terms of harmonic majorants as a generalization of Arellano et al. (2000.

  3. A plasma ball in the Microcosm museum

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    Plasma balls, like the one shown here, are displayed in the Microcosm exhibition where families can visit to learn more about the experiments carried out in a research institute like CERN. Hands-on activities allow visitors to get a step closer to the research activities carried out at CERN.

  4. Visitor playing with a plasma ball

    CERN Multimedia

    1997-01-01

    Plasma balls, like the one shown here, are displayed in the Microcosm exhibition where families can visit to learn more about the experiments carried out in a research institute like CERN. Hands-on activities allow visitors to get a step closer to the research activities carried out at CERN.

  5. 4 π physics with the plastic ball

    International Nuclear Information System (INIS)

    4 π data taken with the Plastic Ball show that cluster production in relativistic nuclear collisions depends on both the size of the participant volume and the finite size of the cluster. The measurement of the degree of thermalization and the search for collective flow will permit the study of the applicability of macroscopic concepts such as temperature and density

  6. Dark Matter Balls Help Supernovae to Explode

    CERN Document Server

    Froggatt, Colin D

    2015-01-01

    As a solution to the well-known problem that the shock wave potentially responsible for the explosion of a supernova actually tends to stall, we propose a new energy source arising from our model for dark matter. Our earlier model proposed that dark matter should consist of cm-large white dwarf-like objects kept together by a skin separating two different sorts of vacua. These dark matter balls or pearls will collect in the middle of any star throughout its lifetime. At some stage during the development of a supernova the balls will begin to take in neutrons and then other surrounding material. By passing into a ball nucleons fall through a potential of order 10 MeV, causing a severe production of heat - of order 10 foe for a solar mass of material eaten by the balls. The temperature in the iron core will thereby be raised, splitting up the iron into smaller nuclei. This provides a mechanism for reviving the shock wave when it arrives and making the supernova explosion really occur. The onset of the heating d...

  7. Selection of Parameters in Ball-Spinning

    Institute of Scientific and Technical Information of China (English)

    Maosheng LI; Yongnian YAN; Shihong ZHANG; Dachang KANG

    2004-01-01

    Nowadays, with the development of spinning processes, more and more systematic research about spinning parameters has been published. Based on these results, a routing about how to select spinning parameters has been gradually formed. However, ball spinning, due to its own features plus research lack, is still unclear about its parameter selections. In addition, some manufacture-enterprises only notice the use of this technique whereas ignore the theory creation. The optimal parameters about the ball spinning although have been released from these enterprises but in fact not a helpful theory for other researchers and producers. Focus on selecting the parameters based on the trial-and-error, this article has carried a series of experiments to study the influence on the spinning working course from those parameters, especially the peeling phenomena, and the tube diameter bulging. An optimal graph of the working angle, the axial feeding rate, and the acceptable working course is put forward. Additionally, based on the theory of the minimal reduction rate, the selection of the ball diameter is finally described. Thus, it has given the rules to get the proper parameters in ball spinning.

  8. Crystal Ball results on tau decays

    International Nuclear Information System (INIS)

    This report reviews measurements and upper limit determinations for a number of exclusive 1-prong tau decay modes using the Crystal Ball detector. These results are important input to the apparent discrepancy between the topological and sum-of-exclusive branching fractions in 1-prong tau decays

  9. Fractal Aggregates in Tennis Ball Systems

    Science.gov (United States)

    Sabin, J.; Bandin, M.; Prieto, G.; Sarmiento, F.

    2009-01-01

    We present a new practical exercise to explain the mechanisms of aggregation of some colloids which are otherwise not easy to understand. We have used tennis balls to simulate, in a visual way, the aggregation of colloids under reaction-limited colloid aggregation (RLCA) and diffusion-limited colloid aggregation (DLCA) regimes. We have used the…

  10. The Ball Aptitude Battery (Test Review).

    Science.gov (United States)

    Hall, Alfred E.

    1985-01-01

    The 12 subtests of the Ball Aptitude Battery (BAB) listed in the administration manual were described. The reviewer believes this aptitude battery, designed for use with high school students and adults in job selection and placement, needs major improvements. It is suggested that the BAB be used solely for research purposes. (DWH)

  11. The dynamic behavior of squash balls

    Science.gov (United States)

    Lewis, Gareth J.; Arnold, J. Cris; Griffiths, Iwan W.

    2011-03-01

    The behavior of a squash ball constitutes an excellent case study of the dynamic behavior of rubbery materials. It is shown that the complex viscoelastic behavior of rubber can be investigated using simple drop bounce tests and compression tests. The drop tests show that the coefficient of restitution increases as the ball temperature increases. The compression tests show that as the speed of compression increases or as the ball temperature decreases, the compressive force and the energy loss both increase. These effects are due to the viscoelastic nature of the rubber and are an excellent example of the time-temperature equivalence of polymers. Compression tests were performed on balls with small holes at the base to separate the effects of the internal air pressure from the material deformation. It was found that the internal air pressure contributed about one-third to the compressive force, but contributed little to energy loss. This behavior shows that the rubber material dominates the rebound behavior and that the normal warming up process at the start of a squash game is important to raise the temperature of the rubber rather than to increase the internal air pressure.

  12. Neutrino Balls and Gamma-Ray Bursts

    CERN Document Server

    Holdom, B

    1994-01-01

    We propose a mechanism by which the neutrino emission from a supernova-type explosion can be converted into a gamma-ray burst of total energy $\\sim 10^{50}$ ergs. This occurs naturally if the explosion is situated inside a ball of trapped neutrinos, which in turn may lie at a galactic core. There are possible unique signatures of this scenario.

  13. 4. pi. physics with the plastic ball

    Energy Technology Data Exchange (ETDEWEB)

    Gutbrod, H.H.; Loehner, H.; Poskanzer, A.M.; Renner, T.; Riedesel, H.; Ritter, H.G.; Warwick, A.; Weik, F.; Wieman, H.

    1982-10-01

    4 ..pi.. data taken with the Plastic Ball show that cluster production in relativistic nuclear collisions depends on both the size of the participant volume and the finite size of the cluster. The measurement of the degree of thermalization and the search for collective flow will permit the study of the applicability of macroscopic concepts such as temperature and density.

  14. Soccer Ball Production for Nike in Pakistan

    NARCIS (Netherlands)

    K.A. Siegmann (Karin Astrid)

    2008-01-01

    textabstractThis paper looks at how Nike’s soccer ball suppliers (previous and current) in Sialkot (Pakistan) fare in relation to the company’s code of ethics. While minimum required working conditions are implemented, the criteria for social and environmental compliance are not met with. The multin

  15. Spherical polytropic balls cannot mimic black holes

    Science.gov (United States)

    Saida, Hiromi; Fujisawa, Atsuhito; Yoo, Chul-Moon; Nambu, Yasusada

    2016-04-01

    The so-called black hole shadow is a dark region which is expected to appear in a fine image of optical observation of black holes. It is essentially an absorption cross section of the black hole, and the boundary of shadow is determined by unstable circular orbits of photons (UCOP). If there exists a compact object possessing UCOP but no black hole horizon, it can provide us with the same shadow image as black holes, and detection of a shadow image cannot be direct evidence of black hole existence. This paper examines whether or not such compact objects can exist under some suitable conditions. We investigate thoroughly the static spherical polytropic ball of perfect fluid with single polytrope index, and then investigate a representative example of a piecewise polytropic ball. Our result is that the spherical polytropic ball which we have investigated cannot possess UCOP, if the speed of sound at the center is subluminal (slower than light). This means that, if the polytrope treated in this paper is a good model of stellar matter in compact objects, the detection of a shadow image can be regarded as good evidence of black hole existence. As a by-product, we have found the upper bound of the mass-to-radius ratio of a polytropic ball with single index, M_{ast }/R_{ast } < 0.281, under the condition of subluminal sound speed.

  16. Intelligent monitoring of ball bearing conditions

    Science.gov (United States)

    Liu, T. I.; Mengel, J. M.

    1992-09-01

    Ball bearings are widely used in various kinds of robots, manufacturing machines, and equipment. In order to enhance productivity and improve product quality, an on-line monitoring system is essential to check the status of ball bearings. In this work, peak amplitude in the frequency domain, peak RMS, and the power spectrum were used as indirect indices to develop a system for monitoring and classifying ball bearing defects. These indices were then processed by artificial neural networks. Six different cases of ball bearing states were observed. The data from these observations were then input into neural networks with different architectures to train these neural networks in a learning process. All the trained neural networks are capable of distinguishing the normal bearings from defective bearings with a 100 percent success rate. They can also classify the bearing conditions into six different states with a success rate of up to 97 per cent. The effects of training set sizes and neural network structures on the monitoring performance have also been investigated.

  17. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    International Nuclear Information System (INIS)

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  18. Design and Testing of a Bionic Dancing Prosthesis.

    Science.gov (United States)

    Rouse, Elliott J; Villagaray-Carski, Nathan C; Emerson, Robert W; Herr, Hugh M

    2015-01-01

    Traditionally, prosthetic leg research has focused on improving mobility for activities of daily living. Artistic expression such as dance, however, is not a common research topic and consequently prosthetic technology for dance has been severely limited for the disabled. This work focuses on investigating the ankle joint kinetics and kinematics during a Latin-American dance to provide unique motor options for disabled individuals beyond those of daily living. The objective of this study was to develop a control system for a bionic ankle prosthesis that outperforms conventional prostheses when dancing the rumba. The biomechanics of the ankle joint of a non-amputee, professional dancer were acquired for the development of the bionic control system. Subsequently, a professional dancer who received a traumatic transtibial amputation in April 2013 tested the bionic dance prosthesis and a conventional, passive prosthesis for comparison. The ability to provide similar torque-angle behavior of the biological ankle was assessed to quantify the biological realism of the prostheses. The bionic dancing prosthesis overlapped with 37 ± 6% of the non-amputee ankle torque and ankle angle data, compared to 26 ± 2% for the conventional, passive prosthesis, a statistically greater overlap (p = 0.01). This study lays the foundation for quantifying unique, expressive activity modes currently unavailable to individuals with disabilities. Future work will focus on an expansion of the methods and types of dance investigated in this work. PMID:26285201

  19. A new tracheal prosthesis made from collagen grafted mesh.

    Science.gov (United States)

    Okumura, N; Nakamura, T; Takimoto, Y; Natsume, T; Teramachi, M; Tomihata, K; Ikada, Y; Shimizu, Y

    1993-01-01

    The authors studied the efficacy of a new tracheal prosthesis made from mesh. The prosthesis, 50 mm long and 18-22 mm in diameter, is made from a Marlex mesh cylinder reinforced with a continuous polypropylene spiral that is grafted and coated with porcine collagen to increase its biocompatibility and provide an airtight seal during the initial implantation stage. Circumferential surgical resection and replacement of a seven to nine ring segment of the cervical trachea was performed in 20 adult mongrel dogs. At the time of surgery, a silicone tube was inserted into the tracheal prosthetic lumen to promote secretory transportation until the prosthesis was covered with host tissue. The silicone tube was removed during fiber bronchoscopy 1 month after surgery. With the exception of the prostheses in 3 dogs that died of unrelated causes, all were infiltrated by connective tissue and incorporated completely by the host. One of these 17 dogs died of suffocation caused by luminal stenosis 2.5 months after surgery, but the others survived until they were killed at more than 6 months. The luminal surfaces of the reconstructed tracheae were covered with respiratory epithelium to varying degrees, and in one dog killed at 22 months after surgery, confluent epithelization throughout the length of the prosthesis was confirmed histologically. In eight dogs, prosthetic luminal stenosis occurred because of overgrowth of granulation tissue, which generally was mild in all but three dogs. The authors conclude that this tracheal prosthesis is highly biocompatible and shows promise for clinical application. PMID:8268582

  20. [Design and study of carbon fiber tracheal prosthesis].

    Science.gov (United States)

    Qi, L; Liu, D; Han, Z; Wang, F

    1998-12-01

    32 healty adult dogs were selected for this experiment. 10 of them were subjected to the tracheal biomechanics test using indices including the relation between stretcher ratio (lambda) and stress (T), the squeeze stress (delta jy) of medical silk thread on trachea, the side stress (Ts) inducing the tracheal collapse, the functional maximum angle (psi max) of tracheal, and the sever area torsion angle (theta max) of tracheal functional maximum curved. According to the indices measured, two types of tracheal prosthesis were designed, and were made of carbon fiber and silicon. They were the straight tube type tracheal prosthesis and the bifurcate type tracheal prosthesis. The straight tube type tracheal prosthesis was studied with a design of two groups comprising a total of 11 dogs. In the experiment group (n = 6), the outer surface of the tube was not coated with silicon, the average survival period was 379.8 days. In the control group (n = 5), the outer surface of the tube was coated with silicon, the average survival period was 90.4 days. The bifurcate type tracheal prosthesis was studied in 11 dogs, the average survival period was 4.32 days. The main causes of death in the experiment were infection and anastomotic dehiscent. PMID:12552773

  1. Correlation analysis between the interface membrane and loose hip prosthesis

    Institute of Scientific and Technical Information of China (English)

    Jian-bing Ma; Yu-ming Zhang; Xiang-dong Meng; Miao Liu

    2009-01-01

    Objective To analyze the cause of prosthesis loosening by observing the interface membranes harvested during the hip restoration operation. Methods A total of 28 specimens of interface membrane around the loose prosthesis were harvested from 28 patients undergoing the restoration of total hip replacement. All the specimens underwent the observation of appearance, light microscopy and scanning electronic microscopy(SEM). Results All the gaps around the loose prosthesis were filled with interface membrane of different thickness. The color of the most interface membrane was madder red, and the other one third of membrane was black. The comparatively thicker membrane was similar to scar connective tissue while the thinner was similar to fiber membrane. A large number of wear debris, macrophages and foreign-body giant cells were found under light microscope. With SEM observation a large number of different diameter collagen fibra structures that looked like scar tissues were arranged disorderly in a great mass, foreign particles and bone debris of different size were distributed unevenly, and the fibroblast was distributed in the collagen fiber. Conclusion Wear debris is related to inflammatory cell response around the interface membrane of the loose prosthesis. The wear debris engulfed by macrophage stimulates the interface membrane to release bone resorption factors (such as TNF) which lead to osteolysis, and this is one of the most important causes of the prosthesis loosening.

  2. Split-Framework in Mandibular Implant-Supported Prosthesis

    Directory of Open Access Journals (Sweden)

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  3. Design and Testing of a Bionic Dancing Prosthesis.

    Directory of Open Access Journals (Sweden)

    Elliott J Rouse

    Full Text Available Traditionally, prosthetic leg research has focused on improving mobility for activities of daily living. Artistic expression such as dance, however, is not a common research topic and consequently prosthetic technology for dance has been severely limited for the disabled. This work focuses on investigating the ankle joint kinetics and kinematics during a Latin-American dance to provide unique motor options for disabled individuals beyond those of daily living. The objective of this study was to develop a control system for a bionic ankle prosthesis that outperforms conventional prostheses when dancing the rumba. The biomechanics of the ankle joint of a non-amputee, professional dancer were acquired for the development of the bionic control system. Subsequently, a professional dancer who received a traumatic transtibial amputation in April 2013 tested the bionic dance prosthesis and a conventional, passive prosthesis for comparison. The ability to provide similar torque-angle behavior of the biological ankle was assessed to quantify the biological realism of the prostheses. The bionic dancing prosthesis overlapped with 37 ± 6% of the non-amputee ankle torque and ankle angle data, compared to 26 ± 2% for the conventional, passive prosthesis, a statistically greater overlap (p = 0.01. This study lays the foundation for quantifying unique, expressive activity modes currently unavailable to individuals with disabilities. Future work will focus on an expansion of the methods and types of dance investigated in this work.

  4. Q-balls in the Wick-Cutkosky model

    CERN Document Server

    Nugaev, E Ya

    2016-01-01

    In the present paper Q-ball solutions in the Wick-Cutkosky model are examined in detail. A remarkable feature of the Wick-Cutkosky model is that it admits analytical treatment for the most part of the analysis of Q-balls. An attempt is made to describe Q-balls as bound states of scalar particles.

  5. Interrelation between ball lightning and optically induced forces

    International Nuclear Information System (INIS)

    Optically induced forces are considered as a key factor for explaining the phenomenon of ball lightning. They can provide not only the existence of ball lightning in the form of self-confined intense white light circulating in a spherical shell of air strongly compressed by the light but also the anomalous motion of ball lightning in the terrestrial atmosphere. (paper)

  6. Temperature and Coefficient of Restitution of a Table Tennis Ball

    Directory of Open Access Journals (Sweden)

    Yoonyoung Chang

    2016-01-01

    Full Text Available The coefficient of restitution (COR of a bouncing table tennis ball was measured at varying ball temperatures with a Motion Detector. It was found that there is a negative linear relationship between the COR and the temperature of the table tennis ball for temperatures ranging from 5 to 56 ̊C.

  7. Measuring the Rebound Resilience of a Bouncing Ball

    Science.gov (United States)

    Wadhwa, Ajay

    2012-01-01

    Some balls which are made of high-quality rubber (an elastomeric) material, such as tennis or squash balls, could be used for the determination of an important property of such materials called resilience. Since a bouncing ball involves a single impact we call this property "rebound resilience" and express it as the ratio of the rebound height to…

  8. A short-term study in sheep with the Groningen temporomandibular joint prosthesis

    NARCIS (Netherlands)

    van Loon, JP; de Bont, LGM; Spijkervet, FKL; Verkerke, GJ; Liem, RSB

    2000-01-01

    As part of the pre-clinical testing process of a newly developed temporomandibular joint (TMJ) prosthesis, animal experiments were performed. In 14 sheep, the right TMJ was replaced by the developed TMJ prosthesis. The prosthesis consisted of a skull part, a mandibular part and an intervening polyet

  9. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ...-constrained cemented prosthesis. 888.3490 Section 888.3490 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a...

  10. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a...

  11. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3300 Section 888.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained cemented or uncemented prosthesis is a device intended to be implanted to replace a hip joint. The...

  12. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ...-constrained cemented prosthesis. 888.3520 Section 888.3520 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended...

  13. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthesis modification instrument for ossicular... § 874.3540 Prosthesis modification instrument for ossicular replacement surgery. (a) Identification. A prosthesis modification instrument for ossicular replacement surgery is a device intended for use by...

  14. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... porous-coated uncemented prosthesis. 888.3565 Section 888.3565 Food and Drugs FOOD AND DRUG... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a...

  15. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ...-constrained cemented prosthesis. 888.3530 Section 888.3530 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device...

  16. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3360 Section 888.3360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be...

  17. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3100 Section 888.3100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace...

  18. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3200 Section 888.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/metal constrained uncemented prosthesis. (a) Identification. A finger joint metal/metal constrained uncemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal...

  19. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3660 Section 888.3660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace...

  20. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... constrained cemented prosthesis. 888.3550 Section 888.3550 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a...

  1. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip...

  2. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a...

  3. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... resurfacing uncemented prosthesis. 888.3580 Section 888.3580 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made...

  4. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer prosthesis is a device intended to be implanted made of medical grade silicone elastomer used to replace...

  5. 21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3570 Section 888.3570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium-molybdenum, intended...

  6. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3400 Section 888.3400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic resurfacing prosthesis is a device intended to be implanted to replace a portion of the hip...

  7. 21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3690 Section 888.3690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as...

  8. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3220 Section 888.3220 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal...

  9. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3800 Section 888.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist...

  10. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained cemented prosthesis is a device intended to be implanted to replace a metacarpophalangeal (finger)...

  11. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3160 Section 888.3160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  12. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3650 Section 888.3650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace...

  13. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ...-constrained cemented prosthesis. 888.3500 Section 888.3500 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a...

  14. 21 CFR 888.3180 - Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3180 Section 888.3180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis. (a) Identification. An elbow joint humeral (hemi-elbow) metallic uncemented prosthesis is a device intended to be implanted made of...

  15. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3480 Section 888.3480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Knee joint femorotibial metallic constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metallic constrained cemented prosthesis is a device intended to be implanted to replace part of...

  16. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3110 Section 888.3110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  17. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3150 Section 888.3150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace an elbow joint. It is made...

  18. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace...

  19. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a...

  20. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3120 Section 888.3120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace an ankle joint. The...

  1. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ...-constrained cemented prosthesis. 888.3540 Section 888.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a...

  2. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3590 Section 888.3590 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be...

  3. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3510 Section 888.3510 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace...

  4. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... uncemented prosthesis. 888.3310 Section 888.3310 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted...

  5. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal constrained cemented prosthesis... constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a... as cobalt-chromium-molybdenum, and is limited to those prostheses intended for use with bone...

  6. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... cemented prosthesis. 888.3680 Section 888.3680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket)...

  7. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a hip joint. The device...

  8. 21 CFR 878.3540 - Silicone gel-filled breast prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Silicone gel-filled breast prosthesis. 878.3540... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3540 Silicone gel-filled breast prosthesis. (a) Identification—(1) Single-lumen silicone gel-filled breast prosthesis....

  9. Energy density calculations for ball-lightning-like luminous silicon balls

    International Nuclear Information System (INIS)

    The energy density of a luminous silicon ball [Phys. Rev. Lett. 98 048501 (2007)] is calculated for a model with a metal core surrounded by an atmosphere of silicon oxides. Experimental data combined with the molecular orbital calculations of the oxidation enthalpy lead to a mean energy density of 3.9 MJ m-3, which is within the range of estimates from other ball lightning models. This result provides good evidence to support the silicon-based model. (methodological notes)

  10. Disposition of weapon-grade plutonium with pebble bed type HTGRs using Pu burner balls and Th breeder balls

    International Nuclear Information System (INIS)

    A concept of reactor system was developed with which weapons-grade plutonium could be made perfectly worthless in use for weapons. It is a pebble bed type HTGR using Pu burner ball fuels and Th breeder ball fuels. The residual amounts of 239Pu in spent Pu balls become less than 1% of the initial loading. Furthermore, a method was found that the power coefficient could be made negative by heavy Pu loading in the Pu burner ball fuels

  11. Performance and welfare of rabbit does in various caging systems.

    Science.gov (United States)

    Mikó, A; Matics, Zs; Gerencsér, Zs; Odermatt, M; Radnai, I; Nagy, I; Szendrő, K; Szendrő, Zs

    2014-07-01

    The objective of the study was to compare production and welfare of rabbit does and their kits housed in various types of cages. Female rabbits were randomly allocated to four groups with the following cage types: CN: common wire-mesh flat-deck cage, without footrest; CF: cage similar to the CN but with plastic footrest; ECWP: enlarged cage with wire-mesh platform; and ECPP: extra enlarged cage with plastic-mesh platform. All does were inseminated on the same day, 11 days after kindlings. Reproductive performance was evaluated during the first five consecutive kindlings. Severity of sore hocks was scored at each insemination. Location preference of the does and the platform usage of their kits were evaluated. Kindling rate, litter size (total born, born alive, alive at 21 and 35 days) and kit mortality were not significantly influenced by the cage types. The litter weight at 21 days was higher in ECWP and ECPP cages than in the CF group (3516, 3576 and 3291 g, respectively; P2.5 cm) and 3 to 4 (3=callus opened, cracks present; 4=wounds) were 58%, 60%, 78% and 48%, and 0%, 5%, 0% and 48% in groups ECPP, ECWP, CF and CN, respectively. Higher number of daily nest visits was observed for CF does than for ECWP does (12.5 v. 5.9; P2/day) was higher in the CF group than in the ECWP group (12.1 v. 3.2%; Pplastic footrests and plastic-mesh platforms in conventional and/or large cages reduced sore hocks' problems, plastic-mesh platforms were more used by both does and kits compared with the wire-mesh platforms. PMID:26263030

  12. Nasal prosthesis for a patient with xeroderma pigmentosum

    Directory of Open Access Journals (Sweden)

    Suresh Kumar

    2013-01-01

    Full Text Available Acquired facial defects caused by extirpation of neoplasms, congenital malformations or traumatic injury results in a huge functional, cosmetic and psychological handicap in those patients. These defects can be restored by facial prosthesis using different materials and retention methods to achieve a lifelike appearance and function. This clinical report describes a treatment schedule using silicone nasal prosthesis, which is mechanically retained for a patient who has undergone a partial rhinectomy due to basal cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of patient with a mechanically retained design using a spectacle glass frame without any prosthetic adhesives so that the patient is more comfortable and confident to resume daily activities.

  13. Acetabular prosthesis: Proff of migration with ruler and pencil?

    International Nuclear Information System (INIS)

    Conventional X-ray films were made with varying degrees of tilt of a pelvic phantom containing an acetabular prosthesis. The position of the prosthesis was then reconstructed graphically. The measurement errors were calculated and an estimate was made for the tilt. There is a linear correlation between the measurement error and the tilt of the prosthesis. Therefore a tilt dependent maximum error can be calculated. This error is very small for small degrees of tilt, so that acetabular migration can in this instance be evaluated with greater confidence than with other graphical methods. The error also correlates with the determination of the selected region of the acetabulum, but not with the position of the central focus spot or image magnification. (orig.)

  14. Research, design and development project Myoelectric Prosthesis of Upper Limb

    Energy Technology Data Exchange (ETDEWEB)

    Galiano, L; Montaner, E; Flecha, A [Bioparx, J Hernandez 1101, Parana, ERios (Argentina)

    2007-11-15

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives.

  15. Research, design & development project Myoelectric Prosthesis of Upper Limb

    Science.gov (United States)

    Galiano, L.; Montaner, E.; Flecha, A.

    2007-11-01

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives.

  16. Komposit Laminate Rami Epoksi Sebagai Bahan Alternatif Socket Prosthesis

    Directory of Open Access Journals (Sweden)

    Agustinus P. Irawan

    2009-01-01

    Full Text Available pure plant oil, biofuel, coconut oil, palm oil, jatropha oilSocket is the most important component in a prosthesis making. Performance criteria for prosthetic socket material include strength, durability, minimal weight, comfort, and minimal fabrication cost. This research attempts to analyze the strength of ramie fiber reinforced epoxy laminate composite as an alternative of socket prosthesis. The research based on ASTM D 3039/D 3039M for tensile strength and ASTM D 695 for compressive strength. The ramie fiber used was a continuous fiber 100 % Ne14'S, with Epoxy Resin Bakelite EPR 174 and Epoxy Hardener V-140. The sample test was created using a hand lay-up method. The result of this research is presented in a correlation of finsile strength (st, compression strength (sc, elasticity modulus (E versus fraction volume of fiber (Vf. The result is then being compared with some of the prosthesis material’s strength produced by Otto Bock. The analysis was completed with the mode of the failure observation by using Scanning Electron Microscope (SEM. The result concludes that the ramie fiber reinforced epoxy laminate composite is potentially developed further as a socket prosthesis material on Vf 40 – 50 %. Tensile strength and specific strength that has been generated was higher than that of several materias for socket prosthesis, including fiberglass. The mode of the failure found were a brittle failure on Vf: 10-30%, debonding and delamination on Vf: 40-50%. Abstract in Bahasa Indonesia: Socket merupakan bagian terpenting dalam pembuatan prosthesis. Kriteria bahan socket prosthesis antara lain kekuatan, ketahanan, ringan, kenyamanan dan biaya produksi yang rendah. Penelitian ini bertujuan menganalisis kekuatan komposit laminate berpenguat serat rami epoksi sebagai bahan alternatif socket prosthesis. Pengujian kekuatan mengacu standar ASTM D 3039/D 3039M uji tarik dan ASTM D 695 uji tekan. Serat rami yang digunakan berupa serat kontinyu jenis

  17. Research, design and development project Myoelectric Prosthesis of Upper Limb

    International Nuclear Information System (INIS)

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives

  18. Endohedral dynamics of push-pull rotor-functionalized cages.

    Science.gov (United States)

    Krick, Marcel; Holstein, Julian; Würtele, Christian; Clever, Guido H

    2016-08-16

    A series of [Pd2L4] coordination cages featuring endohedral functionalities in central backbone positions was synthesized. Although attached via C[double bond, length as m-dash]C double bonds, the substituents behave as molecular rotors. This is explained by their pronounced donor-acceptor character which lowers rotational barriers and allows for electronic control over the spinning rates inside the cage. The dynamic behaviour of the free ligands, assembled cages and host-guest complexes is compared with the aid of NMR experiments, X-ray structure analysis and molecular modelling. PMID:27484435

  19. The planimetric unfold method of fullerene cage structure

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Two kinds of planimetric diagrams, which consist of the boat form F6 and F5, the storm petrel form F6 and F5, respectively, were proposed to express the geometric structure of fullerene cage in this study. There are two chief advantages using the diagrams: (ⅰ) the spatial symmetrical characteristic of fullerene cage is not destroyed; (ⅱ) the coordination forms of F5 and F6 in the structure can be clearly expressed. This work has laid the foundation for studying the structural geometry of fullerene cage and its quantum chemistry and property.

  20. Bemisia tabaci: A new clip-cage for biological studies

    OpenAIRE

    Muñiz, M.; Nombela, G.

    2001-01-01

    This new clip-cage has been designed in our laboratory. It is a transparent plastic truncated cone clip-cage (3.6 cm x 2.6 cm diameter; 4 cm high). A very thin polypropylene mesh (30 holes/inch) is attached to the bottom by paraffin wax. We have used this clip-cage attached to the under surface of the leaves in our studies on the biology of both B and Q biotypes of Bemisia tabaci with excellent results.

  1. Comparison of Titanium vs. Polycel Total Ossicular Replacement Prosthesis

    Directory of Open Access Journals (Sweden)

    Mohammad Faramarzi

    2016-01-01

    Full Text Available Introduction: Even though modern technology progresses so rapidly, annals of otology are replete with so many challenging article, which often compare various types of prosthesis. Since there has not been a prospective randomized clinical trial study which compares the hearing result of total ossicular replacement prosthesis made of Titanium with omega connector and Polycel in the literature, we decided to perform a study encompassing this issue.   Materials and Methods: 105 patients, who were in the 2nd stage of their operation and who needed total ossicular replacement prosthesis, were included in this prospective single blind randomized clinical trial study. Patients were classified in two groups: titanium Kurz (TTP™ -Vario system, Kurz GmbH, Dusslingen, Germany with omega connector and Polycel (Sheehy Plastipore Polycel, Medtronic Xomed Inc. The duration of the follow up was 6-12 months. In order to evaluate hearing results, pure tone audiometric in 0.5, 1, 2, and 4 kHz were checked. In addition, speech reception threshold was recorded. A successful surgery was defined as having a postoperative air–bone gap within 20 dB.   Results: We accomplished successful hearing in 64.4% of patients with titanium and 65% of patients with a Polycel prosthesis.Improvement in speech reception threshold was 11.5 dB in the titanium group and 13 dB in the Polycel group. In other words, there was no significant difference between the two groups. In addition, air-bone gap improvement after ossiculoplasty was 11.2 dB in the patients with a titanium prosthesis and 12.4 dB in the Polycel group. In fact, the difference was not significant.   Conclusion: We found that both the titanium and the Polycel prosthesis improve speech reception threshold and air-bone gap closure in a similar manner.

  2. Steel balls forming by cross rolling with upsetting

    Directory of Open Access Journals (Sweden)

    Z. Pater

    2013-01-01

    Full Text Available The paper describes a process of forming four balls with a diameter of 22 mm by means of cross rolling with upsetting. The paper also presents the tool used to form semi-finished balls. Owing to the application of the finite element method (FEM, the course of the rolling process as well as temperature and strain distributions in the obtained balls could be presented. The rolling tests conducted in laboratory conditions at the Lublin University of Technology have proved that the balls produced with the developed rolling method meet the demands for grinding media used in ball mills.

  3. Lawn tennis balls, Rolling friction experiment and Trouton viscosity

    CERN Document Server

    Singh, Ankit; Kulkarni, Kaustubh; Budhraja, Abhishek; Tej, K R Sai; Sankarlingam, Satish; Biswas, Anindya Kumar

    2008-01-01

    Three lawn tennis balls were arbitrarily taken. One ball was new, one was moderately old and another was old. We have fabricated a conveyor belt set-up and measured rolling friction coefficients, $\\mu_{r}$, of the three balls as a function of their angular velocities, $\\omega$. For the new ball, quadratic fit is perfect. For the moderately old ball, linear fit is accurate. In all the three cases, from linear fits, we obtain $k_{rol}$, where, $\\mu_{r}= k_{rol} \\omega + intercept$. We deduce $k_{rol}$ theoretically also, assuming Trouton ratio as three. The experimental results and theoretical estimates are of the same order of magnitude.

  4. Vision-based surface defect inspection of metal balls

    International Nuclear Information System (INIS)

    A machine vision system developed for inspecting metal ball surface defects is presented. The proposed system is capable of inspecting the entire surface of a ball by capturing multiple gray-scale images with two progressive CCD cameras as the ball rolls on an inclined rail. The specular reflectance of the metal surface is lessened by installing a shade around the ball. Defects are detected by simply comparing each captured image with its corresponding reference image. The system built for the experiment could sort two chrome balls per second with a spatial resolution better than 0.1 mm. (technical design note)

  5. In vivo performance of photovoltaic subretinal prosthesis

    Science.gov (United States)

    Mandel, Yossi; Goetz, George; Lavinsky, Daniel; Huie, Phil; Mathieson, Keith; Wang, Lele; Kamins, Theodore; Manivanh, Richard; Harris, James; Palanker, Daniel

    2013-02-01

    We have developed a photovoltaic retinal prosthesis, in which camera-captured images are projected onto the retina using pulsed near-IR light. Each pixel in the subretinal implant directly converts pulsed light into local electric current to stimulate the nearby inner retinal neurons. 30 μm-thick implants with pixel sizes of 280, 140 and 70 μm were successfully implanted in the subretinal space of wild type (WT, Long-Evans) and degenerate (Royal College of Surgeons, RCS) rats. Optical Coherence Tomography and fluorescein angiography demonstrated normal retinal thickness and healthy vasculature above the implants upon 6 months follow-up. Stimulation with NIR pulses over the implant elicited robust visual evoked potentials (VEP) at safe irradiance levels. Thresholds increased with decreasing pulse duration and pixel size: with 10 ms pulses it went from 0.5 mW/mm2 on 280 μm pixels to 1.1 mW/mm2 on 140 μm pixels, to 2.1 mW/mm2 on 70 μm pixels. Latency of the implant-evoked VEP was at least 30 ms shorter than in response evoked by the visible light, due to lack of phototransduction. Like with the visible light stimulation in normal sighted animals, amplitude of the implant-induced VEP increased logarithmically with peak irradiance and pulse duration. It decreased with increasing frequency similar to the visible light response in the range of 2 - 10 Hz, but decreased slower than the visible light response at 20 - 40 Hz. Modular design of the photovoltaic arrays allows scalability to a large number of pixels, and combined with the ease of implantation, offers a promising approach to restoration of sight in patients blinded by retinal degenerative diseases.

  6. Active Bone Conduction Prosthesis: BonebridgeTM

    Science.gov (United States)

    Zernotti, Mario E.; Sarasty, Andrea Bravo

    2015-01-01

    Introduction Bone conduction implants are indicated for patients with conductive and mixed hearing loss, as well as for patients with single-sided deafness (SSD). The transcutaneous technology avoids several complications of the percutaneous bone conduction implants including skin reaction, skin growth over the abutment, and wound infection. The Bonebridge (MED-EL, Austria) prosthesis is a semi-implantable hearing system: the BCI (Bone Conduction Implant) is the implantable part that contains the Bone Conduction-Floating Mass Transducer (BC-FMT), which applies the vibrations directly to the bone; the external component is the audio processor Amadé BB (MED-EL, Austria), which digitally processes the sound and sends the information through the coil to the internal part. Bonebridge may be implanted through three different approaches: the transmastoid, the retrosigmoid, or the middle fossa approach. Objective This systematic review aims to describe the world́s first active bone conduction implant system, Bonebridge, as well as describe the surgical techniques in the three possible approaches, showing results from implant centers in the world in terms of functional gain, speech reception thresholds and word recognition scores. Data Synthesis The authors searched the MEDLINE database using the key term Bonebridge. They selected only five publications to include in this systematic review. The review analyzes 20 patients that received Bonebridge implants with different approaches and pathologies. Conclusion Bonebridge is a solution for patients with conductive/mixed hearing loss and SSD with different surgical approaches, depending on their anatomy. The system imparts fewer complications than percutaneous bone conduction implants and shows proven benefits in speech discrimination and functional gain. PMID:26491482

  7. Active Bone Conduction Prosthesis: Bonebridge(TM).

    Science.gov (United States)

    Zernotti, Mario E; Sarasty, Andrea Bravo

    2015-10-01

    Introduction Bone conduction implants are indicated for patients with conductive and mixed hearing loss, as well as for patients with single-sided deafness (SSD). The transcutaneous technology avoids several complications of the percutaneous bone conduction implants including skin reaction, skin growth over the abutment, and wound infection. The Bonebridge (MED-EL, Austria) prosthesis is a semi-implantable hearing system: the BCI (Bone Conduction Implant) is the implantable part that contains the Bone Conduction-Floating Mass Transducer (BC-FMT), which applies the vibrations directly to the bone; the external component is the audio processor Amadé BB (MED-EL, Austria), which digitally processes the sound and sends the information through the coil to the internal part. Bonebridge may be implanted through three different approaches: the transmastoid, the retrosigmoid, or the middle fossa approach. Objective This systematic review aims to describe the world́s first active bone conduction implant system, Bonebridge, as well as describe the surgical techniques in the three possible approaches, showing results from implant centers in the world in terms of functional gain, speech reception thresholds and word recognition scores. Data Synthesis The authors searched the MEDLINE database using the key term Bonebridge. They selected only five publications to include in this systematic review. The review analyzes 20 patients that received Bonebridge implants with different approaches and pathologies. Conclusion Bonebridge is a solution for patients with conductive/mixed hearing loss and SSD with different surgical approaches, depending on their anatomy. The system imparts fewer complications than percutaneous bone conduction implants and shows proven benefits in speech discrimination and functional gain. PMID:26491482

  8. Modul femur prosthesis for major upper femoral bone defects

    International Nuclear Information System (INIS)

    The Koelner modul femur prosthesis MECROSET represents a device to be composed of standardised units. It allows the surgeon dealing with large bone defects of the upper femoral end to meet the special local requirements by building up the appropriate implant. This device may cope with bone losses of up to 22 cms, measured down from the tip of the major trochanter. Combination with ordinary cups is possible. Indications proven are upper femoral defects following disease, exchange of prosthesis and trauma. The ten patients thus provided did not show any complications during a 2-year period of observation. Long-term results are still to be awaited. (orig.)

  9. Design and characterization of a powered elbow prosthesis.

    Science.gov (United States)

    Bennett, Daniel A; Mitchell, Jason; Goldfarb, Michael

    2015-08-01

    This paper describes the design of a powered elbow prosthesis, which incorporates a belt and cable drive transmission with a brushless DC motor to achieve an output torque of approximately 18.4 Nm, a backdrive torque of 1.5 Nm, and a speed of up to 360 deg/s while remaining within the anthropomorphic envelope with regard to mass and size. The measured torque and speed of the prosthesis is commensurate with nominal capability of the natural limb (for purposes of performing activities of daily living). PMID:26736791

  10. The specialty of bucomaxillofacial prosthesis and its performance in Dentistry

    Directory of Open Access Journals (Sweden)

    Fabiano Geronasso SIMÕES

    2009-09-01

    Full Text Available Introduction:The human attempt to restore the bucomaxillofacialregion by heteroplasia is as old as the formation of civilizations. Archaeological excavations have revealed Egyptian mummies with artificial eyes, nose and ears.Objective and literature review:The aim of this study was to report the evolution and importance of bucomaxillofacial prosthesis,which might be the greatest challenge ofdental surgeons within the specialties of Dentistry.Conclusion: Thebucomaxillofacial prosthesis outreach in health sector is extremelyimportant,and Dentistry plays an essential role in modern society tothe rehabilitation of patients in need of such treatment.

  11. Aspiration of tracheoesophageal prosthesis in a laryngectomized patient

    Directory of Open Access Journals (Sweden)

    Conte Sergio C

    2012-08-01

    Full Text Available Abstract Background The voice prosthesis inserted into a tracheoesophageal fistula has become the most widely used device for voice rehabilitation in patients with total laryngectomy. Case presentation We describe a case of tracheoesophageal prosthesis’ (TEP aspiration in a laryngectomized patient, with permanent tracheal stoma, that appeared during standard cleaning procedure, despite a programme of training for the safe management of patients with voice prosthesis. Conclusions The definitive diagnosis and treatment were performed by flexible bronchoscopy, that may be considered the procedure of choice in these cases, also on the basis of the literature.

  12. Sitting on stability balls: biomechanics evaluation in a workplace setting.

    Science.gov (United States)

    Schult, Tamara M; Awosika, Ebi R; Schmunk, Sandra K; Hodgson, Michael J; Heymach, Bria L; Parker, Celestine Dent

    2013-01-01

    Use of a stability ball alone and stability ball chair were evaluated in the Veterans Health Administration as possible alternatives to incorporate with regular office chair use. The evaluation of stability ball use was conducted under the auspices of a work site health promotion program as a cross-over trial with participants rotating through use of the stability ball, stability ball chair, and regular office chair on a monthly basis for a total duration of 3 months. Rotations on regular office chairs served as the control. Three medical facilities participated. A total of 193 employees completed a baseline questionnaire; 159 completed at least one post-rotation questionnaire. Self-reported measures included perceived posture when sitting, perceptions of overall balance, energy levels, job performance, safety, and pain. Use was associated with improvements in perceived posture (p < 0.0001) and energy levels (p = 0.007) for stability ball users compared with the office chair control, and improvements in perceived posture (p < 0.0001) and overall balance (p = 0.05) for stability ball chair users compared with the control. Use of stability balls at work decreases the likelihood of reporting pain from regular office chair use from approximately 45% to 21%. Alternatively, a high number of participants reported pain with use of the stability ball alone and stability ball chair, 42% and 45%, respectively. The perceived risks and benefits of stability ball use should be weighed when incorporating use. PMID:23252582

  13. Rehabilitation of orbital defect with silicone orbital prosthesis retained by dental implants

    Science.gov (United States)

    Guttal, Satyabodh Shesharaj; Desai, Jhanvi; Kudva, Adarsh; Patil, Basavaraj R

    2016-01-01

    Orbital defects can result from cancer, birth anomalies, or trauma leading to an onslaught of problems in the function and psyche of the patient. These defects are restored by surgical reconstruction and followed by placement of orbital prosthesis for cosmetic makeup. The use of dental implants in retaining orbital prosthesis improves patient acceptance of the prosthesis owing to better retention and stability than conventional adhesive retained prosthesis. This case report describes a custom-made magnetic retentive assembly anchored by a dental implant which offers the orbital prosthesis the simplicity of self-alignment and ease of use. PMID:26953033

  14. Percutaneous Revision of a Testicular Prosthesis is Safe, Cost-effective, and Provides Good Patient Satisfaction

    Directory of Open Access Journals (Sweden)

    Eugene B. Cone

    2015-09-01

    Full Text Available Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.

  15. Ball Machine Usage in Tennis: Movement Initiation and Swing Timing While Returning Balls from a Ball Machine and from a Real Server

    Directory of Open Access Journals (Sweden)

    Jan Carboch, Vladimir Süss, Tomas Kocib

    2014-06-01

    Full Text Available Practicing with the use of a ball machine could handicap a player compared to playing against an actual opponent. Recent studies have shown some differences in swing timing and movement coordination, when a player faces a ball projection machine as opposed to a human opponent. We focused on the time of movement initiation and on stroke timing during returning tennis serves (simulated by a ball machine or by a real server. Receivers’ movements were measured on a tennis court. In spite of using a serving ball speed from 90 kph to 135 kph, results showed significant differences in movement initiation and backswing duration between serves received from a ball machine and serves received from a real server. Players had shorter movement initiation when they faced a ball machine. Backswing duration was longer for the group using a ball machine. That demonstrates different movement timing of tennis returns when players face a ball machine. Use of ball machines in tennis practice should be limited as it may disrupt stroke timing.

  16. Isoguanine octamer: From bowl to ball

    Science.gov (United States)

    Gu, Jiande; Wang, Jing; Leszczynski, Jerzy

    2007-09-01

    Isoguanine (2-oxo-6-amino-guanine, isoG) can form the higher-order self-pairing ionophore structures by regulating the concentration of metal ions. The metal ion coordinated isoG-tetrads adopt bowl-like shape with the metal ion located at the bottom of the bowl. The present study of the formation of the H-bonded octamers ((isoG 4-M +) 2; M + = Na +, K +) illustrates that the bowl-shaped isoG 4-M + complexes are able to form the extraordinary ball-shaped octamers (isoG 4-M +) 2 H-bonded through the H(N6) and N7 sites. A moderate energy barrier predicted for the process of separating the ball-shaped octamer into two bowl-shaped tetrads and the unique structural features of the octamer suggests a possibility towards construction of the self-assembled isoG nanostructures.

  17. Linear diffusion into a Faraday cage.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Lin, Yau Tang; Merewether, Kimball O.; Chen, Kenneth C.

    2011-11-01

    Linear lightning diffusion into a Faraday cage is studied. An early-time integral valid for large ratios of enclosure size to enclosure thickness and small relative permeability ({mu}/{mu}{sub 0} {le} 10) is used for this study. Existing solutions for nearby lightning impulse responses of electrically thick-wall enclosures are refined and extended to calculate the nearby lightning magnetic field (H) and time-derivative magnetic field (HDOT) inside enclosures of varying thickness caused by a decaying exponential excitation. For a direct strike scenario, the early-time integral for a worst-case line source outside the enclosure caused by an impulse is simplified and numerically integrated to give the interior H and HDOT at the location closest to the source as well as a function of distance from the source. H and HDOT enclosure response functions for decaying exponentials are considered for an enclosure wall of any thickness. Simple formulas are derived to provide a description of enclosure interior H and HDOT as well. Direct strike voltage and current bounds for a single-turn optimally-coupled loop for all three waveforms are also given.

  18. La cage qui cache : La Cage Dorée de Ruben Alves

    Directory of Open Access Journals (Sweden)

    Cristina Marinho

    2015-12-01

    Full Text Available The French Comedy La Cage Dorée (produced by the luso descendant Ruben Alves, 2013 success seems to be mainly due to its clichés of Portuguese epics in Paris, and its miseries may not have been underlined enough. Thus, under this apparently naif portrait an intriguing painting of Portuguese immigrants’ French dis-integration may really be hiding, which is the aim of this essay, on one hand, to bring out and, on the other one, to clarify, by questioning comparative critical common denominators of the two countries.

  19. La cage qui cache : La Cage Dorée de Ruben Alves

    Directory of Open Access Journals (Sweden)

    Cristina Marinho

    2015-01-01

    Full Text Available The French Comedy La Cage Dorée (produced by the luso descendant Ruben Alves, 2013 success seems to be mainly due to its clichés of Portuguese epics in Paris, and its miseries may not have been underlined enough. Thus, under this apparently naif portrait an intriguing painting of Portuguese immigrants’ French dis-integration may really be hiding, which is the aim of this essay, on one hand, to bring out and, on the other one, to clarify, by questioning comparative critical common denominators of the two countries.

  20. Evaluation of the pharmacophoric motif of the caged Garcinia xanthones†

    OpenAIRE

    Chantarasriwong, Oraphin; Cho, Woo Cheal; Batova, Ayse; Chavasiri, Warinthorn; Moore, Curtis; Rheingold, Arnold L.; Theodorakis, Emmanuel A.

    2009-01-01

    The combination of unique structure and potent bioactivity exhibited by several family members of the caged Garcinia xanthones, led us to evaluate their pharmacophore. We have developed a Pd(0)-catalyzed method for the reverse prenylation of catechols that, together with a Claisen/Diels–Alder reaction cascade, provides rapid and efficient access to various caged analogues. Evaluation of the growth inhibitory activity of these compounds leads to the conclusion that the intact ABC ring system c...

  1. Cage experiments in an East African mangrove forest: a synthesis

    OpenAIRE

    Schrijvers, J.; Vincx, M.

    1997-01-01

    The impact of epibenthos on endobenthos has frequently been investigated for temperate saltmarsh regions by using cage exclusion experiments. Although the insight into the function of the endobenthos of mangrove forests is crucial for their management, very few cage experiments have so far been carried out in such areas. The present paper summarises the result of such experiments in a typical East African mangrove forest at Gazi Bay about 60 km south of Mombasa, Kenya. Epibenthic animals were...

  2. Catalogue Note on Taner Ceylan's Cage of Flesh (2012)

    OpenAIRE

    Cakirlar, C.; Delice, S.

    2012-01-01

    Cage of Flesh (Ten Kafesi), the most recent piece by the photorealist painter Taner Ceylan, engages with the politics of and the erotics within representation in Orientalist painting by confronting the viewer with a re-imagined figure of an odalisque. Following his highly acclaimed Lost Painting Series that featured Fake World (2011), 1640 (2011), 1879 (2011), 1923 (2010) and 1881 (2010), Cage of Flesh uses an ingenious amalgam of allusions to both Orientalist eroticisation of female flesh an...

  3. Experimental setup for the measurement of induction motor cage currents

    International Nuclear Information System (INIS)

    An experimental setup for measurement of the currents flowing in the rotor bars of induction motors during synchronous no-load tests is described in the paper. The experimental verification of the high-frequency phenomena in the rotor cage is fundamental for a deep insight of the additional loss estimation by numerical methods. The attention is mainly focused on the analysis and design of the transducers developed for the cage current measurement

  4. Soccer Ball Production for Nike in Pakistan

    OpenAIRE

    Siegmann, Karin Astrid

    2008-01-01

    textabstractThis paper looks at how Nike’s soccer ball suppliers (previous and current) in Sialkot (Pakistan) fare in relation to the company’s code of ethics. While minimum required working conditions are implemented, the criteria for social and environmental compliance are not met with. The multinational’s decision to withdraw orders from the previous supplier ostensibly due to allegations of child labour and unauthorised subcontracting hit large sections of the workforce, especially rural,...

  5. Tuned ball absorber acting in one direction

    Czech Academy of Sciences Publication Activity Database

    Pirner, Miroš; Urushadze, Shota

    US : SEM, 2004 - (Wicks, A.), s. 150-158 ISBN 0-912053-86-0. ISSN 1046-6770. [IMAC-XXII Conference on Structural Dynamic s. Dearborn (US), 26.01.2004-29.01.2004] R&D Projects: GA AV ČR KJB2071303 Institutional research plan: CEZ:AV0Z2071913 Keywords : ball absorber * acceleration * frequency Subject RIV: JM - Building Engineering

  6. Independence, low balling and learning effects

    OpenAIRE

    Simons, Dirk

    2007-01-01

    Independent auditors serve as gatekeepers of public securities markets, but ongoing competition among audit firms could harm auditors’ independence. For instance, a Green Paper of the European Union finds that especially audits of large and prestigious clients are hard-fought in terms of price competition. Major concerns are related to a pricing behavior called low balling. Here, the auditor sets the first period’s fee below the audit costs -incurring a loss for the initial audit- in order to...

  7. Ball-thrower's fracture of the humerus

    International Nuclear Information System (INIS)

    A relatively rare case of ball-thrower's fracture of the humerus is presented. Severe muscular action is an uncommon cause of humeral fractures but has been well documented in the orthopedic literature. To our knowledge, this fracture has not been described in the radiology literature, and awareness of this entity could preclude further unnecessary workup. The mechanism of injury and its typical radiographic appearance is described. (orig.)

  8. Gravitational effects on critical Q-balls

    Science.gov (United States)

    Metaxas, D.

    2007-04-01

    In a cosmological phase transition in theories that admit Q-balls there is a value of the soliton charge above which the soliton becomes unstable and expands, converting space to the true vacuum, much like a critical bubble in the case of ordinary tunneling. Here I consider the effects of gravity on these solitons and I calculate the lowest gravitational corrections to the critical radius and charge.

  9. Gravitational effects on critical Q-balls

    CERN Document Server

    Metaxas, D

    2004-01-01

    In a first-order phase transition in theories that admit Q-balls there is a value of the soliton charge above which the soliton becomes unstable and expands, converting space to the true vacuum, much like a critical bubble in the case of ordinary tunneling. Here I consider the effects of gravity on these solitons and I calculate the lowest gravitational corrections to the critical radius and charge.

  10. Low-Wear Ball-Bearing Separator

    Science.gov (United States)

    Hawkinson, Elden L.

    1991-01-01

    Proposed ball-bearing separator for use in cryogenic pump stronger and more resistant to wear. Consists of molded plastic-and-metal composite ring imbued with solid lubricant and containing embedded metal ring. Obtains combination of strength and lubricity. Before molding and machining, ring includes tooling portion for handling and indexing. Molded composite blend of PTFE and fluorinated ethylene/propylene (FEP) filled with brass and bronze powder and molybdenum disulfide powder.

  11. CVD carbon powders modified by ball milling

    Directory of Open Access Journals (Sweden)

    Kazmierczak Tomasz

    2015-09-01

    Full Text Available Carbon powders produced using a plasma assisted chemical vapor deposition (CVD methods are an interesting subject of research. One of the most interesting methods of synthesizing these powders is using radio frequency plasma. This method, originally used in deposition of carbon films containing different sp2/sp3 ratios, also makes possible to produce carbon structures in the form of powder. Results of research related to the mechanical modification of these powders have been presented. The powders were modified using a planetary ball mill with varying parameters, such as milling speed, time, ball/powder mass ratio and additional liquids. Changes in morphology and particle sizes were measured using scanning electron microscopy and dynamic light scattering. Phase composition was analyzed using Raman spectroscopy. The influence of individual parameters on the modification outcome was estimated using statistical method. The research proved that the size of obtained powders is mostly influenced by the milling speed and the amount of balls. Powders tend to form conglomerates sized up to hundreds of micrometers. Additionally, it is possible to obtain nanopowders with the size around 100 nm. Furthermore, application of additional liquid, i.e. water in the process reduces the graphitization of the powder, which takes place during dry milling.

  12. Ball plasma dynamics for FBX BURNER reactor

    International Nuclear Information System (INIS)

    The authors have been conducting fundamental experiments on the moving plasma balls in the major axis direction. This has a fundamental importance for the quasi-steady fusion reactor scheme FBX BURNER. This configuration is the descendants of Spheromak type nuclear fusion scheme but with long toroidal field coils. The main issues have been focused onto the dynamic stability of the moving plasma balls. The second issue is the collision between two successive plasma balls as shown. This shows a basic result from an optical measurement. The comparison with magnetic measurements shows peculiar but interesting features of the system. The dimension of the plasma injector is 2 m in length as a whole. It is in a coaxial configuration. The external electrode is 150 mm in inner diameter and the inner electrode is 50 mm in diameter. This is attached to a 1 m insulation reservoir with same inner diameter. An axial magnetic field up to 0.1 Tesla is applied on the discharge with a current of up to 10 kA in few ms. The authors show their experimental and numerical simulation results on these problems

  13. Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages

    OpenAIRE

    Cabraja Mario; Oezdemir Soner; Koeppen Daniel; Kroppenstedt Stefan

    2012-01-01

    Abstract Background Titanium (TTN) cages have a higher modulus of elasticity when compared with polyetheretherketone (PEEK) cages. This suggests that TTN-cages could show more frequent cage subsidence after anterior cervical discectomy and fusion (ACDF) and therefore might lead to a higher loss of correction. We compared the long term results of stand-alone PEEK- and TTN-cages in a comparable patient collective that was operated under identical operative settings. Methods From 2002 to 2007 15...

  14. Enhanced Neurobehavioral Outcomes of Action Observation Prosthesis Training.

    Science.gov (United States)

    Cusack, William F; Thach, Scott; Patterson, Rebecca; Acker, Dan; Kistenberg, Robert S; Wheaton, Lewis A

    2016-07-01

    Background Previous studies have demonstrated improved neurobehavioral outcomes when prosthesis users learn task-specific behaviors by imitating movements of prosthesis users (matched limb) compared with intact limbs (mismatched limb). Objective This study is the first to use a unique combination of neurophysiological and task performance methods to investigate prosthetic device training strategies from a cognitive motor control perspective. Intact nonamputated prosthesis users (NAPUs) donned specially adapted prosthetic devices to simulate the wrist and forearm movement that persons with transradial limb loss experience. The hypothesis is that NAPUs trained with matched limb imitation would show greater engagement of parietofrontal regions and reduced movement variability compared with their counterparts trained with a mismatched limb. Methods Training elapsed over 3 days comprised alternating periods of video demonstration observation followed by action imitation. At the beginning and end of the training protocol, participants performed a cued movement paradigm while electroencephalography and electrogoniometry data were collected to track changes in cortical activity and movement variability, respectively. Results Matched limb participants showed greater engagement of motor-related areas while mismatched limb participants showed greater engagement of the parietooccipital system. Matched limb participants also showed lower movement variability. Conclusions These results indicate that the type of limb imitated influences neural and behavioral strategies for novel prosthetic device usage. This finding is important, as customary prosthetic rehabilitation with intact therapists involves mismatched limb imitation that may exacerbate challenges in adapting to new motor patterns demanded by prosthesis use. PMID:26438442

  15. Nuclear medicine and articulation prosthesis of the lower limbs

    International Nuclear Information System (INIS)

    Several nuclear medicine procedures can help the surgeons in the diagnosis of the complications of articulations prosthesis of the lower limbs, in particular in case of torpid infection. Even if the diagnosis remains uncertain, the indications and the interpretation of these procedures benefit of a close collaboration between nuclear medicine specialist and clinicians. (author)

  16. Groningen temporomandibular joint prosthesis. Development and first clinical application

    NARCIS (Netherlands)

    van Loon, JP; de Bont, LGM; Stegenga, B; Spijkervet, FKL; Verkerke, GJ

    2002-01-01

    Patients with a severely degenerated temporomandibular joint (TMJ) may benefit from an alloplastic TMJ replacement. The aim of the study was to develop a safe and properly functioning TMJ prosthesis. The design was based on imitation of anterior condylar translation by an inferiorly located centre o

  17. Guest Editorial: Training protocol for powered shoulder prosthesis

    Directory of Open Access Journals (Sweden)

    Linda Resnik, PT, PhD

    2015-01-01

    Full Text Available There is a scarcity of literature on rehabilitation training protocols for upper-limb prosthesis use. Seminal textbooks and articles describe protocols for training individuals to use conventional body-powered, myoelectric, or passive prosthetic devices and were written prior to the introduction of multifunction prosthetic hands and more advanced prosthetic technologies.

  18. Guest Editorial: Training protocol for powered shoulder prosthesis

    OpenAIRE

    Linda Resnik, PT, PhD; Shana Lieberman Klinger, MA; Kathryn Korp, OTR/L, OTD; Lisa Smurr Walters, OTR/L, CHT

    2015-01-01

    There is a scarcity of literature on rehabilitation training protocols for upper-limb prosthesis use. Seminal textbooks and articles describe protocols for training individuals to use conventional body-powered, myoelectric, or passive prosthetic devices and were written prior to the introduction of multifunction prosthetic hands and more advanced prosthetic technologies.

  19. Engineering Design of an Adaptive Leg Prosthesis Using Biological Principles

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Dentel, Andy; Invarsdottir, Thorunn;

    2010-01-01

    The biomimetic design process is explored through a design case: An adaptive leg prosthesis. The aim is to investigate if the biomimetic design process can be carried out with a minimum of biological knowledge and without using advanced design methods. In the design case biomimetic design was...

  20. Histologic analysis of a retrieved hydroxyapatite-coated femoral prosthesis

    DEFF Research Database (Denmark)

    Søballe, K; Gotfredsen, K; Brockstedt-Rasmussen, H;

    1991-01-01

    A hydroxyapatite-coated hip hemi-prosthesis was retrieved from a 98-year-old osteoporotic woman 12 weeks after implantation. Histologic analysis revealed bone and fibrous tissue almost evenly distributed around the surface of the implant circumference. Quantitative histologic analysis showed that...

  1. Strain-stress analysis of surface prosthesis of hip joint

    Czech Academy of Sciences Publication Activity Database

    Návrat, Tomáš; Fuis, Vladimír; Florian, Z.; Hlavoň, Pavel

    Vol. XXI Congress. Taipei, Taiwan : Elsevier, 2007 - (Huiskes, R.). S559-S559 ISBN 9789868299016. ISSN 0021-9290. [ISB 2007. 01.07.2007-05.07.2007, Taipei] R&D Projects: GA ČR GA101/05/0136 Institutional research plan: CEZ:AV0Z20760514 Keywords : surface prosthesis * hip joint * FEM Subject RIV: BO - Biophysics

  2. Strain-stress analysis of surface prosthesis of hip joint

    Czech Academy of Sciences Publication Activity Database

    Návrat, Tomáš; Fuis, Vladimír; Florian, Z.; Hlavoň, Pavel

    2007-01-01

    Roč. 40, č. 2 (2007), S559-S559. ISSN 0021-9290. [ISB 2007. Taipei, 01.07.2007-05.07.2007] R&D Projects: GA ČR GA101/05/0136 Institutional research plan: CEZ:AV0Z20760514 Keywords : surface prosthesis * hip joint * FEM Subject RIV: BO - Biophysics Impact factor: 2.897, year: 2007

  3. Aerodynamics in the classroom and at the ball park

    Science.gov (United States)

    Cross, Rod

    2012-04-01

    Experiments suitable for classroom projects or demonstrations are described concerning the aerodynamics of polystyrene balls. A light ball with sufficient backspin can curve vertically upward through the air, defying gravity and providing a dramatic visual demonstration of the Magnus effect. A ball projected with backspin can also curve downward with a vertical acceleration greater than that due to gravity if the Magnus force is negative. These effects were investigated by filming the flight of balls projected in an approximately horizontal direction so that the lift and drag forces could be easily measured. The balls were also fitted with artificial raised seams and projected with backspin toward a vertical target in order to measure the sideways deflection over a known horizontal distance. It was found that (a) a ball with a seam on one side can deflect either left or right depending on its launch speed and (b) a ball with a baseball seam can also deflect sideways even when there is no sideways component of the drag or lift forces acting on the ball. Depending on the orientations of the seam and the spin axis, a sideways force on a baseball can arise either if there is rough patch on one side of the ball or if there is a smooth patch. A scuff ball with a rough patch on one side is illegal in baseball. The effect of a smooth patch is a surprising new observation.

  4. Evaluation of individually ventilated cage systems for laboratory rodents: cage environment and animal health aspects.

    Science.gov (United States)

    Höglund, A U; Renström, A

    2001-01-01

    The use of individually ventilated cage (IVC) systems has become an attractive housing regime of laboratory rodents. The benefits of IVC systems are, reportedly, a high degree of containment combined with relative ease of handling, and a high degree of protection from allergenes. In the present study we tested whether two IVC systems (BioZone VentiRack, IVC1 and Techniplast SealSafe, IVC2S), in which we held mature male NMRI mice, were constructed to maintain a constant differential pressure, positive or negative, during a prolonged period of time. We also measured ammonia (NH3) concentrations after about 2 weeks of use, and CO2 build-up during a 60 min simulated power failure situation. In addition, animal weight development and bite-wound frequency were recorded (Renström et al. 2000). From the present study it is concluded that the IVC1 air handling system provides a more uniform and balanced differential pressure than the IVC2S. Both systems effectively scavenge NH3 when bedding material is not soaked by urine. Although the IVCs are dependent on the continual function of the fans to work properly, it seems unlikely that CO2 concentrations increase to hazardous levels, as a result of a one hour power failure, with the type of cages used in this study. Differences in weight development and bite-wound occurrence were noted between the two IVC systems. Causes for these differences could not be established and need more investigation. PMID:11201288

  5. 14C-age tracers in global ocean circulation models

    Science.gov (United States)

    Koeve, W.; Wagner, H.; Kähler, P.; Oschlies, A.

    2015-07-01

    The natural abundance of 14C in total CO2 dissolved in seawater (DIC) is a property applied to evaluate the water age structure and circulation in the ocean and in ocean models. In this study we use three different representations of the global ocean circulation augmented with a suite of idealised tracers to study the potential and limitations of using natural 14C to determine water age, which is the time elapsed since a body of water has been in contact with the atmosphere. We find that, globally, bulk 14C-age is dominated by two equally important components, one associated with ageing, i.e. the time component of circulation, and one associated with a "preformed 14C-age". The latter quantity exists because of the slow and incomplete atmosphere-ocean equilibration of 14C particularly in high latitudes where many water masses form. In the ocean's interior, preformed 14C-age behaves like a passive tracer. The relative contribution of the preformed component to bulk 14C-age varies regionally within a given model, but also between models. Regional variability in the Atlantic Ocean is associated with the mixing of waters with very different end members of preformed 14C-age. Here, variations in the preformed component over space and time mask the circulation component to an extent that its patterns are not detectable from bulk 14C-age. Between models, the variability of preformed 14C-age can also be considerable (factor of 2), related to the combination of physical model parameters, which influence circulation dynamics or gas exchange. The preformed component was found to be very sensitive to gas exchange and moderately sensitive to ice cover. In our model evaluation, the choice of the gas-exchange constant from within the currently accepted range of uncertainty had such a strong influence on preformed and bulk 14C-age that if model evaluation would be based on bulk 14C-age, it could easily impair the evaluation and tuning of a model's circulation on global and regional

  6. Multicomponent Protein Cage Architectures for Photocatalysis

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Arunava [Univ. of Alabama, Tuscaloosa, AL (United States); Prevelige, Peter E [Univ. of Alabama, Birmingham, AL (United States)

    2016-01-04

    The primary goal of the project was to develop protein-templated approaches for the synthesis and directed assembly of semiconductor nanomaterials that are efficient for visible light absorption and hydrogen production. In general, visible-light-driven photocatalysis reactions exhibit low quantum efficiency for solar energy conversion primarily because of materials-related issues and limitations, such as the control of the band gap, band structure, photochemical stability, and available reactive surface area of the photocatalyst. Synthesis of multicomponent hierarchical nano-architectures, consisting of semiconductor nanoparticles (NPs) with desired optical properties fabricated to maximize spatial proximity for optimum electron and energy transfer represents an attractive route for addressing the problem. Virus capsids are highly symmetrical, self-assembling protein cage nanoparticles that exist in a range of sizes and symmetries. Selective deposition of inorganic, by design, at specific locations on virus capsids affords precise control over the size, spacing, and assembly of nanomaterials, resulting in uniform and reproducible nano-architectures. We utilized the self-assembling capabilities of the 420 subunit, 60 nm icosahedral, P22 virus capsid to direct the nucleation, growth, and proximity of a range of component materials. Controlled fabrication on the exterior of the temperature stable shell was achieved by genetically encoding specific binding peptides into an externally exposed loop which is displayed on each of the 420 coat protein subunits. Localization of complimentary materials to the interior of the particle was achieved through the use “scaffolding-fusion proteins. The scaffolding domain drives coat protein polymerization resulting in a coat protein shell surrounding a core of approximately 300 scaffolding/fusion molecules. The fusion domain comprises a peptide which specifically binds the semiconductor material of interest.

  7. Amplatzer occlusion of paravalvular leak of mitral mechanical prosthesis following a reoperation for thrombosed mitral mechanical prosthesis

    OpenAIRE

    Nikolic, Aleksandar; Schranz, Ditmaer; HRISTOV, Nikola; Mitrev, Zan

    2008-01-01

    We describe a case of a 46-year-old woman with dehiscence and paravalvular leak of a second-time replaced mitral mechanical prosthesis, successfully treated with Amplatzer occlusion of the paravalvular leak, thus avoiding a second reoperation and improving the patient’s symptoms.

  8. Powered ankle-foot prosthesis for the improvement of amputee ambulation.

    Science.gov (United States)

    Au, Samuel K; Herr, Hugh; Weber, Jeff; Martinez-Villalpando, Ernesto C

    2007-01-01

    This paper presents the mechanical design, control scheme, and clinical evaluation of a novel, motorized ankle-foot prosthesis, called MIT Powered Ankle-Foot Prosthesis. Unlike a conventional passive-elastic ankle-foot prosthesis, this prosthesis can provide active mechanical power during the stance period of walking. The basic architecture of the prosthesis is a unidirectional spring, configured in parallel with a force-controllable actuator with series elasticity. With this architecture, the anklefoot prosthesis matches the size and weight of the human ankle, and is also capable of delivering high mechanical power and torque observed in normal human walking. We also propose a biomimetic control scheme that allows the prosthesis to mimic the normal human ankle behavior during walking. To evaluate the performance of the prosthesis, we measured the rate of oxygen consumption of three unilateral transtibial amputees walking at self-selected speeds to estimate the metabolic walking economy. We find that the powered prosthesis improves amputee metabolic economy from 7% to 20% compared to the conventional passive-elastic prostheses (Flex-Foot Ceterus and Freedom Innovations Sierra), even though the powered system is twofold heavier than the conventional devices. This result highlights the benefit of performing net positive work at the ankle joint to amputee ambulation and also suggests a new direction for further advancement of an ankle-foot prosthesis. PMID:18002631

  9. CAGE BREEDING OF WARM WATER FRESHWATER FISH SPECIES

    Directory of Open Access Journals (Sweden)

    Roman Safner

    2008-10-01

    Full Text Available In the 1970s, Croatia became actively involved in the contemporary trend of breeding fish in floating cages. In addition to various species of marine fishes, breeding was attempted with trout, carp, catfish, cisco and salmon. Of the above freshwater fish species, specific standards were established only for the cage breeding of rainbow trout. Cage breeding of the remaining species remained at the level of occasional attempts, with more of an experimental than a commercial character. The regular attempts to master this technique for cage breeding of warm water freshwater fish species were aimed at achieving the known benefits of such breeding, such as simplicity of implementing technological measures, easier establishment of the breeding system, simpler manipulation, the possibility of denser colonies per unit volume with a high level of production, easier adaptations to market conditions and fewer initial structural investments. Despite the many advantages, the main reasons for the lack of greater implementation of the cage breeding technology for warm water species of freshwater fish include problems in obtaining the appropriate category and quantity of healthy fry, the specificity and applicability of physical and chemical properties of the recipients and human error. In evaluating the advantages and disadvantages, the final decision on the justification of cage breeding for individual warm water freshwater species must be based on both biological and economic factors. Based on the knowledge of cage breeding acquired to date, the rule for virtually all intensive breeding systems is that it is only recommended for those species with high market demand and a high market price. The technology that demands nutrition with highly concentrated feed and other production expenditures is costly, and is therefore not profitable with less expensive fish species. Furthermore, production must be market oriented, i.e. the appropriate market research measures

  10. Q-balls in atomic Bose-Einstein condensates

    CERN Document Server

    Enqvist, K

    2003-01-01

    Relativistic scalar field theories with a conserved global charge Q often possess (meta)stable spherically symmetric soliton solutions, called Q-balls. We elaborate on the perfect formal analogy which exists between Q-balls, and spherically symmetric solitons in certain non-relativistic atomic Bose-Einstein condensates, for which the dominant interatomic interaction can be tuned attractive. The stability of such atomic Q-balls depends on higher-order interatomic interactions, which can render the Q-balls absolutely stable for large Q. In a harmonic trap, present in existing experiments, the Q-ball solution is modified in an essential way. If the trap is significantly prolongated in one direction, however, then genuine solitons do appear, and some of the Q-ball properties studied in a relativistic cosmological context, such as their formation and collisions, can also be addressed experimentally.

  11. Magnetohydrodynamics equilibrium of a self-confined elliptical plasma ball

    International Nuclear Information System (INIS)

    A variational principle is applied to the problem of magnetohydrodynamics (MHD) equilibrium of a self-contained elliptical plasma ball, such as elliptical ball lightning. The principle is appropriate for an approximate solution of partial differential equations with arbitrary boundary shape. The method reduces the partial differential equation to a series of ordinary differential equations and is especially valuable for treating boundaries with nonlinear deformations. The calculations conclude that the pressure distribution and the poloidal current are more uniform in an oblate self-confined plasma ball than that of an elongated plasma ball. The ellipticity of the plasma ball is obviously restricted by its internal pressure, magnetic field, and ambient pressure. Qualitative evidence is presented for the absence of sighting of elongated ball lightning

  12. The methodology of composing the exercises system with fit balls.

    Directory of Open Access Journals (Sweden)

    Voronov N.P.

    2011-02-01

    Full Text Available The original methodology of composing the exercises system with fit balls was considered. More than 10 publications were analysed. On the lesson with fit balls the problem was revealed. In the experiment took part 30 students at the age from 18 till 21. All the famous exercises were systematized. As a result, a big attractiveness and assimilability of the proposed complex was revealed. The effectiveness of the complex of physical exercises with fit balls for students was proved.

  13. Pattern of External Breast Prosthesis Use by Post Mastectomy Breast Cancer Patients in India: Descriptive Study from Tertiary Care Centre.

    Science.gov (United States)

    Ramu, D; Ramesh, Rakesh S; Manjunath, Suraj; Shivakumar; Goel, Vipin; Hemnath, G N; Alexander, Annie

    2015-12-01

    In India, Breast cancer is now the most common cancer in urban and 2nd most common in rural areas [1]. The incidence is rising, more younger women are getting affected and due to increase in survival rates there is an increase in the total number of women suffering from breast Cancer. So far there are no studies evaluating the pattern of breast prosthesis use in Indian scenario. The aim of this study is to address the patterns of external breast prosthesis used in India and view of Indian women on such prosthesis after mastectomy for breast cancer. This was a descriptive longitudinal study. In this study we interviewed (telephonic) 63 people, after three years of completing treatment under The Department of Surgical Oncology, St. Johns medical college, Bangalore. Among the study group, 27 members (40 %) were using various prosthesis, rest 36 women were not using any type of prosthesis. Among the users of prosthesis, silicon prosthesis was used by 6 women, padded cups by 8 women, cloth or cotton by 12 women and 1 woman used other type of prosthesis. Most women use simple items like cloth and cotton (44 %). Next most commonly used prosthesis are padded cups(). Only 22 % of women were found using silicon prosthesis in this study. Most of the well educated patients used external prosthesis either in the form of silicon prosthesis or padded cups. Most of women below age of 50 used external breast prosthesis. Use of prosthesis was more in urban compared to rural population (48 % vs 25 %). Prosthesis users worried more about the body image than women not using prosthesis. 25 % of women using prosthesis had body image issues where as only 5 % of non prosthesis users had such problems. Prosthesis users need improvement in terms of comfort, size, shape and affordability. Most common reasons for not using prosthesis are age, lack of motivation and awareness. Less than half of the women included in this study used external prosthesis after mastectomy for breast cancer

  14. LOW COMPRESSION TENNIS BALLS AND SKILL DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    John Hammond

    2006-12-01

    Full Text Available Coaching aims to improve player performance and coaches have a number of coaching methods and strategies they use to enhance this process. If new methods and ideas can be determined to improve player performance they will change coaching practices and processes. This study investigated the effects of using low compression balls (LCBs during coaching sessions with beginning tennis players. In order to assess the effectiveness of LCBs on skill learning the study employed a quasi-experimental design supported by qualitative and descriptive data. Beginner tennis players took part in coaching sessions, one group using the LCBs while the other group used standard tennis balls. Both groups were administered a skills at the beginning of a series of coaching sessions and again at the end. A statistical investigation of the difference between pre and post-test results was carried out to determine the effect of LCBs on skill learning. Additional qualitative data was obtained through interviews, video capture and the use of performance analysis of typical coaching sessions for each group. The skill test results indicated no difference in skill learning when comparing beginners using the LCBs to those using the standard balls. Coaches reported that the LCBs appeared to have a positive effect on technique development, including aspects of technique that are related to improving power of the shot. Additional benefits were that rallies went on longer and more opportunity for positive reinforcement. In order to provide a more conclusive answer to the effects of LCBs on skill learning and technique development recommendations for future research were established including a more controlled experimental environment and larger sample sizes across a longer period of time

  15. Fourier-Laguerre transform, convolution and wavelets on the ball

    CERN Document Server

    McEwen, J D

    2013-01-01

    We review the Fourier-Laguerre transform, an alternative harmonic analysis on the three-dimensional ball to the usual Fourier-Bessel transform. The Fourier-Laguerre transform exhibits an exact quadrature rule and thus leads to a sampling theorem on the ball. We study the definition of convolution on the ball in this context, showing explicitly how translation on the radial line may be viewed as convolution with a shifted Dirac delta function. We review the exact Fourier-Laguerre wavelet transform on the ball, coined flaglets, and show that flaglets constitute a tight frame.

  16. Biomechanics of Heading a Soccer Ball: Implications for Player Safety

    OpenAIRE

    Charles F. Babbs

    2001-01-01

    To better understand the risk and safety of heading a soccer ball, the author created a set of simple mathematical models based upon Newton�s second law of motion to describe the physics of heading. These models describe the player, the ball, the flight of the ball before impact, the motion of the head and ball during impact, and the effects of all of these upon the intensity and the duration of acceleration of the head. The calculated head accelerations were compared to those during presumab...

  17. Accuracy and Reliability of a New Tennis Ball Machine

    OpenAIRE

    Cyril Brechbuhl, Grégoire Millet, Laurent Schmitt

    2016-01-01

    The aim was to evaluate the reliability of a newly-developed ball machine named 'Hightof', on the field and to assess its accuracy. The experiment was conducted in the collaboration of the 'Hawk-Eye' technology. The accuracy and reliability of this ball machine were assessed during an incremental test, with 1 min of exercise and 30 sec of recovery, where the frequency of the balls increased from 10 to 30 balls·min-1. The initial frequency was 10 and increased by 2 until 22, then by 1 until 30...

  18. RELATIONSHIP BETWEEN MEDICINE BALL EXPLOSIVE POWER TESTS, THROWING BALL VELOCITY AND JUMP PERFORMANCE IN TEAM HANDBALL PLAYERS

    Directory of Open Access Journals (Sweden)

    Mourad Fathloun

    2011-04-01

    Full Text Available In this study, the relationships between medicine ball explosive power tests, jump and handball throwing velocity performance in team handball players were investigated. Explosive test was measured by a medicine ball throw. Specific explosive strength was evaluated by making 3 types of overarm throw: standing position, using an adapted chair (without run-up, T w , a 3-step running throw (T 3-Steps and a jump shot (J S . The jump test (SJ, CMJ and FCMJ were determined using the OptoJump. The medicine ball explosive power test was closely related to T 3-Steps . Significant relationships were observed between medicine ball explosive power tests and (J S and (T w . The Medicine ball explosive power test is also positively related to vertical jump ability represented by Squat Jump (SJ and Countermovement Jump (CMJ. The results suggest an association of the medicine ball explosive power tests to performance in throwing events

  19. Ball Bearing Analysis with the ORBIS Tool

    Science.gov (United States)

    Halpin, Jacob D.

    2016-01-01

    Ball bearing design is critical to the success of aerospace mechanisms. Key bearing performance parameters, such as load capability, stiffness, torque, and life all depend on accurate determination of the internal load distribution. Hence, a good analytical bearing tool that provides both comprehensive capabilities and reliable results becomes a significant asset to the engineer. This paper introduces the ORBIS bearing tool. A discussion of key modeling assumptions and a technical overview is provided. Numerous validation studies and case studies using the ORBIS tool are presented. All results suggest the ORBIS code closely correlates to predictions on bearing internal load distributions, stiffness, deflection and stresses.

  20. Quenching simulation of steel grinding balls

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Hernandez, O.; Reyes, L. A.; Camurri, C.; Carrasco, C.; Garza-Monte-de-Oca, F.; Colas, R.

    2015-07-01

    The phase transformations of high carbon steel during quenching and equalizing were modelled using commercial computer packages based on the finite element method and the kinetic transformation of steel. The model was used to predict the temperature and microstructural changes taking place within balls of two different sizes that are used for grinding mineral ores. A good correlation between the temperatures measured by inserted thermocouples and those predicted by the model was obtained after modifying the thermal conductivity of the steel within the temperature domain at which mixed phases are present. The phase transformations predicted were confirmed by metallographic analyses. (Author)

  1. Tar ball Monitoring Along the Kenyan Beaches.

    OpenAIRE

    Nguta, M.

    1993-01-01

    Observations and measurements of petroleum tar balls on a number of Kenyan beaches were carried out between 1979 and 1982. A large variation in the size and amount of tar deposit at the beaches was recorded. These values ranged from very small pebbles to large lumps of 30 cm in diameter, weighing up to 1.5 kg. The average tar loading during the sampling period ranged from 0-18 g/m2. Between 25-50% by weight of the tar lumps were shell fragments, sand and other nonpetroleum debris. The chemica...

  2. A proposed experiment on ball lightning model

    International Nuclear Information System (INIS)

    Highlights: → We propose to put a glass sphere inside an excited gas. → Then to put a light ray inside the glass in a whispering gallery mode. → If the light is resonant to gas excitation, it will be amplified at every reflection. → In ms time the light in the glass will be amplified, and will melt the glass. → A liquid shell kept integer by electrostriction forces is the ball lightning model. -- Abstract: We propose an experiment for strong light amplification at multiple total reflections from active gaseous media.

  3. Collective flow measured with the Plastic Ball

    International Nuclear Information System (INIS)

    The experimental results from the Plastic Ball detector have contributed vastly to the understanding of the reaction mechanism of nuclear collisions at several hundred MeV per nucleon. The discovery of the collective flow phenomena (bounce-off of spectator fragments, side-splash in the reaction plane, and squeeze-out out of the reaction plane), as they were predicted by hydrodynamical models, has led to the experimental observation of compressed nuclear matter, which is a necessary condition before one can study the equation of state in detail and search for phase transitions at higher energies. 39 refs., 9 figs., 1 tab

  4. Crystal Ball evidence for new states

    International Nuclear Information System (INIS)

    Evidence for three new particles observed in the Crystal Ball detector is presented. The first particle, at 3592 MeV, is seen inclusively in γ transitions from psi', and is thus a candidate for eta/sub c/'. The other two, at 1440 and 1640 MeV, are best seen in exclusive decays of psi involving a prompt γ, and are thus candidates for bound states of two gluons. Detailed reasons are presented to support the contention that these states are distinct from previously observed candidates such as E(1420). Alternative hypotheses are discussed

  5. PROBLEMS OF BIOFOULING ON FISH–CAGE NETS IN AQUACULTURE

    Directory of Open Access Journals (Sweden)

    Merica Slišković

    2002-09-01

    Full Text Available Biofouling on fish–cage netting is a serious technical and economical problem to aquaculture worldwide. Compensation for the effects of biofouling must be included in cage system design and planning, as fouling can dramatically increase both weight and drag. Settlements of sessile plants and animals, with accumulation of the detritus diminish the size of mesh and can rapidly occlude mesh. Negative effect of smaller mesh size is changing in water flow trough the cages. Biofouling problems necessitating purchase of a second sets of nets or more, and frequent cleaning and changing of biofouling. Changing and cleaning frequency depend on many factors such as: location of cages (near the coast or off shore, productivity of that location, time of the year, time period in which the cages are placed on that location (cause of loading of phosphorus and nitrogen from the unconsumed food in the sediment. Net changing and cleaning procedures are labor and capital intensive. Process of the cleaning of the nets is inadequate, especially when there isnžt adequate equipment available as it is case in smaller aquaculture industry. Chemical control of biofouling e. g. use of antifoulants is questioningly cause of their possible negative effects on breeding species and environment.

  6. Femoral hip prosthesis design for Thais using multi-objective shape optimization

    International Nuclear Information System (INIS)

    Highlights: • A multi-objective shape optimization was proposed to design hip prosthesis for Thais. • The prosthesis design was optimized in terms of safety of both cement and prosthesis. • The objective functions used the Soderberg fatigue strength formulations. • Safety factors of the cement and prosthesis are 1.200 and 1.109 respectively. • The newly designed prosthesis also fits well with chosen small-sized Thai femurs. - Abstract: The long-term success of Total Hip Arthroplasty (THA) depends largely on how well the prosthetic components fit the bones. The majority of cemented femoral hip prosthesis failures are due to aseptic loosening, which is possibly caused by cracking of the cement mantle. The strength of cement components is a function of cement mantles having adequate thickness. Since the size and shape of cemented femoral hip prostheses used in Thailand are based on designs for a Caucasian population, they do not properly conform to most Thai patients’ physical requirements. For these reasons, prostheses designed specifically for Thai patients must consider the longevity and functionality of both cement and prosthesis. The objective of this study was to discover a new design for femoral hip prostheses which is not only optimal and safe in terms of both cement and prosthesis, but also fits the selected Thai femur. This study used a small-sized Thai femoral model as a reference model for a new design. Biocompatible stainless steel 316L (SS316L) and polymethylmethacrylate (PMMA) were selected as raw materials for the prosthesis and bone cement respectively. A multi-objective shape optimization program, which is an interface between optimization C program named NSGA-II and a finite element program named ANSYS, was used to optimize longevity of femoral hip prostheses by varying shape parameters at assigned cross-sections of the selected geometry. Maximum walking loads of sixty-kilograms were applied to a finite element model for stress and

  7. [Maxillary prosthesis for better QOL--early setting and faster construction of maxillary prosthesis].

    Science.gov (United States)

    Usui, H; Sakakura, Y; Shimozato, K

    1992-12-01

    The maxillofacial prosthesis (MFP) is well accepted as one of the modalities to ameliolate the postsurgical crippling in the patients with maxillary malignancy. In this report, we analyzed 55 primary cases of MFP out of 100, from July, 1981 to July, 1987 in terms of the time of start after operation, and the duration and procedure of the MFP-making. MFP-making set about within 4 weeks in 35% of patients, 8 weeks in 25%, 12 weeks in 22%, and more than 12 weeks in 18%. The completion of MFP-making averaged 10 days. As a result of simplifying of MFP-making, we shortened a period requiring MFP-making within 3 days in recent 10 cases. There were no adverse effects of early wear of MFP after operation. We believe that early wear of MFP after operation improve the quality of life of patients with maxillary malignancy and considered that wear of MFP is not the completion of treatment, but is one of the procedures of treatment for the patients undergone maxillectomy. PMID:1491275

  8. Influence of Manufacturing Process of Warp-knitted Vascular Prosthesis on the Wall Homogeneity

    Institute of Scientific and Technical Information of China (English)

    王璐; 丁辛

    2003-01-01

    This paper reports the evolution of textile structure and mechanical properties of vascular prosthesis in the level of the whole prosthesis and the constituent filaments with respect to the manufacturing process.The tubular wall of the prosthesis is divided circumferentially into three zones: basic line (BL),remeshing line (RL) and guide line (GL). Some heterogeneity has been observed on the tubular wall in :erms of stitch structure of the prosthesis and linear density of the constituent filaments. The breaking position of the prosthesis under circumferential tensile localizes preferentially in remeshing line that is the weakest zone by warp knitting with double needle bed. Furthermore, the statistical differences of the mechanical properties of the filaments of zone RL, GL and BL have been confirmed too. It is predictable that the deterioration of prosthesis, under physiological loads (periodical pulse blood pressure etc.), could happen firstly in the weaker zone in vivo.

  9. Effects of Furnished Cage Type on Behavior and Welfare of Laying Hens

    OpenAIRE

    LI, XIANG; Chen, Donghua; Li, Jianhong; Bao, Jun

    2015-01-01

    This study was conducted to compare the effects of layout of furniture (a perch, nest, and sandbox) in cages on behavior and welfare of hens. Two hundred and sixteen Hyline Brown laying hens were divided into five groups (treatments) with four replicates per group: small furnished cages (SFC), medium furnished cages type I (MFC-I), medium furnished cages type II (MFC-II), and medium furnished cages type III (MFC-III) and conventional cages (CC). The experiment started at 18 week of age and fi...

  10. Hexaphosphapentaprismane: a new gateway to organophosphorus cage compound chemistry.

    Science.gov (United States)

    al-Ktaifani, Mahmoud M; Bauer, Walter; Bergsträsser, Uwe; Breit, Bernhard; Francis, Matthew D; Heinemann, Frank W; Hitchcock, Peter B; Mack, Andreas; Nixon, John F; Pritzkow, Hans; Regitz, Manfred; Zeller, Matthias; Zenneck, Ulrich

    2002-06-01

    Several independent synthetic routes are described leading to the formation of a novel unsaturated tetracyclic phosphorus carbon cage compound tBu4C4P6 (1), which undergoes a light-induced valence isomerization to produce the first hexaphosphapentaprismane cage tBu4C4P6 (2). A second unsaturated isomer tBu4C4P6 (9) of 1 and the bis-[W(CO)5] complex 13 of 1 are stable towards similar isomerization reactions. Another starting material for the synthesis of the hexaphosphapentaprismane cage tBu4C4P6 (2) is the trimeric mercury complex [(tBu4C4P6)Hg]3 (11), which undergoes elimination of mercury to afford the title compound 2. Single-crystal X-ray structural determinations have been carried out on compounds 1, 2, 9, 11, and 13. PMID:12180342

  11. Biologically tunable reactivity of energetic nanomaterials using protein cages.

    Science.gov (United States)

    Slocik, Joseph M; Crouse, Christopher A; Spowart, Jonathan E; Naik, Rajesh R

    2013-06-12

    The performance of aluminum nanomaterial based energetic formulations is dependent on the mass transport, diffusion distance, and stability of reactive components. Here we use a biologically inspired approach to direct the assembly of oxidizer loaded protein cages onto the surface of aluminum nanoparticles to improve reaction kinetics by reducing the diffusion distance between the reactants. Ferritin protein cages were loaded with ammonium perchlorate (AP) or iron oxide and assembled with nAl to create an oxidation-reduction based energetic reaction and the first demonstration of a nanoscale biobased thermite material. Both materials showed enhanced exothermic behavior in comparison to nanothermite mixtures of bulk free AP or synthesized iron oxide nanopowders prepared without the use of ferritin. In addition, by utilizing a layer-by-layer (LbL) process to build multiple layers of protein cages containing iron oxide and iron oxide/AP on nAl, stoichiometric conditions and energetic performance can be optimized. PMID:23713514

  12. Encapsulation of cobalt nanoparticles in cross-linked-polymer cages

    Energy Technology Data Exchange (ETDEWEB)

    Hatamie, Shadie [Department of Electronic-Science, Fergusson College, Pune 411 004 (India); Dhole, S.D. [Department of Physics, University of Pune, Pune 411 007 (India); Ding, J. [Department of Materials Science and Engineering, National University of Singapore, 7, Engineering Drive 1, Singapore 117574 (Singapore); Kale, S.N. [Department of Electronic-Science, Fergusson College, Pune 411 004 (India)], E-mail: sangeetakale2004@gmail.com

    2009-07-15

    Nanoparticles embedded in polymeric cages give rise to interesting applications ranging from nanocatalysis to drug-delivery systems. In this context, we report on synthesis of cobalt (Co) nanoparticles trapped in polyvinyl alcohol (PVA) matrix to yield self-supporting magnetic films in PVA slime. A 20 nm, Co formed in FCC geometry encapsulated with a weak citrate coat when caged in PVA matrix exhibited persistence of magnetism and good radio-frequency response. Cross-linking of PVA chains to form cage-like structures to arrest Co nanoparticles therein, is believed to be the reason for oxide-free nature of Co, promising applications in biomedicine as well as in radio-frequency shielding.

  13. Mice Do Not Habituate to Metabolism Cage Housing

    DEFF Research Database (Denmark)

    Kalliokoski, Otto; Jacobsen, Kirsten Rosenmaj; Darusman, Huda Shalahudin;

    2013-01-01

    abnormality were monitored. Forced swim tests were conducted to determine whether the animals experienced behavioral despair and the serotonergic integrity was tested using an 8-OH-DPAT challenge. The metabolism cage housed mice excreted approximately tenfold higher amounts of corticosterone metabolites in...... in the present setup. In conclusion, the mice were found not to acclimatize to the metabolism cages whereby concern for animal welfare would dictate that mice should be housed in this way for as short periods as possible. The elevated degree of HPA axis activity, oxidative stress, and increased......The metabolism cage is a barren, non-enriched, environment, combining a number of recognized environmental stressors. We investigated the ability of male BALB/c mice to acclimatize to this form of housing. For three weeks markers of acute and oxidative stress, as well as clinical signs of...

  14. Ion implantation of silicon nitride ball bearings

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.M. [Oak Ridge National Lab., TN (United States); Miner, J.R. [United Technologies, Pratt and Whitney, West Palm Beach, FL (United States)

    1996-09-01

    Hypothesis for ion implantation effect was that stress concentrations reflected into the bulk due to topography such as polishing imperfections, texture in the race, or transferred material, might be reduced due to surface amorphization. 42 control samples were tested to an intended runout period of 60 h. Six ion implanted balls were tested to an extended period of 150 h. Accelerated testing was done in a V groove so that wear was on two narrow wear tracks. Rutherford backscattering, XRPS, profilometry, optical microscopy, nanoindentation hardness, and white light interferometry were used. The balls were implanted with 150-keV C ions at fluence 1.1x10{sup 17}/cm{sup 2}. The samples had preexisting surface defects (C-cracks), so the failure rate of the control group was unacceptable. None of the ion-implanted samples failed in 150 h of testing. Probability of randomly selecting 6 samples from the control group that would perform this well is about 5%, so there is good probability that ion implantation improved performance. Possible reasons are discussed. Wear tracks, microstructure, and impurity content were studied in possible relation to C-cracks.

  15. The method of manufacture of nylon dental partially removable prosthesis using additive technologies

    Science.gov (United States)

    Kashapov, R. N.; Korobkina, A. I.; Platonov, E. V.; Saleeva, G. T.

    2014-12-01

    The article is devoted to the topic of creating new methods of dental prosthesis. The aim of this work is to investigate the possibility of using additive technology to create nylon prosthesis. As a result of experimental studies, was made a sample of nylon partially removable prosthesis using 3D printing has allowed to simplify, accelerate and reduce the coat of manufacturing high-precision nylon dentures.

  16. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  17. Magnetic resonance imaging compatibility test of a cranial prosthesis with titanium screws

    Science.gov (United States)

    Jimenez, R.; Benavides, A.; Flores, D.; Hidalgo, S. S.; Solis, S. E.; Uribe, E.; Rodriguez, A. O.

    2012-10-01

    The follow-up of patients with skull prosthesis is necessary to provide adequate medical care. Skull prostheses for cranioplasty have been developed at the Faculty of Odontology of Universidad Nacional Autonoma de Mexico. We built a skull prosthesis phantom and tested for compatibility with standard magnetic resonance imaging procedures. Results showed full compatibility but susceptibility artefacts occurred due to titanium used to fix the prosthesis to the skull.

  18. The Efficiency of Titanium Middle Ear Prosthesis in Ossicular Chain Reconstruction: Our Experience

    OpenAIRE

    Shah, Kshitij Dhaval; Bradoo, Renuka A.; Joshi, Anagha A.; Sapkale, Deepti D.

    2011-01-01

    Middle ear ossicular reconstruction is a challenging task for any otologist. Over a period of time, surgeons have tried various types of materials as ossicular prosthesis with varying amount of success. In the last decade, numerous studies have been conducted that have proved that titanium prosthesis is biocompatible. We have conducted this study to investigate the efficiency of titanium middle ear prosthesis (Eon Meditech Pvt. Ltd.) in tympanoplasty. Nineteen patients who underwent tympanopl...

  19. Septic failure is not a septic loosening: A case report of a failed shoulder prosthesis

    OpenAIRE

    Yde Engelsma; Pieter Buma; Pieter C Geervliet; Arthur Van Noort

    2012-01-01

    Septic failure of a shoulder arthroplasty due to a low-grade infection is generally called septic loosening. However, it is often not investigated if a prosthesis is genuinely loose. We present a case of a failed resurfacing prosthesis in a 70-year-old woman. This prosthesis failed due to a low-grade infection and a revision procedure was mandatory. All intraoperative cultures were positive and revealed a combination of bacteria. Nevertheless, histology revealed a macroscopic and a microscopi...

  20. Axial penile rigidity influences patient and partner satisfaction after penile prosthesis implantation

    OpenAIRE

    Abdulla Al Ansari; Raidh A. Talib; Onder Canguven; Ahmad Shamsodini

    2013-01-01

    Introduction: Penile prosthesis implantation is one of the treatment choices that is kept for patients who were not satisfied with other treatments. Although penile prosthesis satisfaction rates are higher, there are some dissatisfied patients. The patients’ reasons are mostly shortness and softness of implanted prosthesis. It was previously demonstrated that penile axial rigidity of more than 500 grams is enough for successful vaginal intromission. To our knowledge, there is no study c...