WorldWideScience

Sample records for cables

  1. Superconductor cable

    Science.gov (United States)

    Allais, Arnaud; Schmidt, Frank; Marzahn, Erik

    2010-05-04

    A superconductor cable is described, having a superconductive flexible cable core (1) , which is laid in a cryostat (2, 3, 4), in which the cable core (1) runs in the cryostat (2, 3, 4) in the form of a wave or helix at room temperature.

  2. Cable compliance

    Science.gov (United States)

    Kerley, J.; Eklund, W.; Burkhardt, R.; Rossoni, P.

    1992-06-01

    The object of the investigation was to solve mechanical problems using cable-in-bending and cable-in-torsion. These problems included robotic contacts, targets, and controls using cable compliance. Studies continued in the use of cable compliance for the handicapped and the elderly. These included work stations, walkers, prosthetic knee joints, elbow joints, and wrist joints. More than half of these objects were met, and models were made and studies completed on most of the others. It was concluded that the many different and versatile solutions obtained only opened the door to many future challenges.

  3. VT Cable Systems 2005

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable System dataset (CABLE2005) includes lines depicting the extent of Vermont's cable system as of 12/31/2005. Numerous cable companies...

  4. VT Cable Systems 2007

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable System dataset (CABLE2007) includes lines depicting the extent of Vermont's cable system as of 12/31/2007. Numerous cable companies...

  5. Superconductor cable

    Science.gov (United States)

    Smith, Jr., Darrell F.; Lake, Bill L.; Ballinger, Ronald G.

    1988-01-01

    A superconducting cable comprising an in-situ-formed type II superconductor, e.g. Nb.sub.3 Sn, in association with a stabilizing conductor both in heat transfer relationship with at least one passage adapted to carry liquified gaseous refrigerant. The conductor and said at least one passage are enclosed by a sheath comprising an alloy consisting essentially of about 49% nickel, about 4% chromium, about 3% niobium, about 1.4% titanium, about 1% aluminum, balance essentially iron.

  6. VT Cable Systems 2013

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable dataset (CABLE2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013 in addition to...

  7. CABLES MUSCULARES

    Directory of Open Access Journals (Sweden)

    Alejandro Gómez

    Full Text Available Los cables musculares o fibras de nitinol presentan una excelente alternativa a los actuadores convencionales, con una fuerza de actuación muy alta, equivalente a la de los actuadores hidráulicos, proporcionalmente a su peso, además de su acción silenciosa. Este material, inventado en 1963, aún no es muy conocido y de ahí que se haya realizado una recopilación de sus propiedades. Entre ellas, la temperatura de transición es la más importante, por ser la que activa la aleación. Muchos sistemas se han creado para alcanzar adecuadamente la temperatura de transición, y también se continúa en la investigación de métodos que ayuden a lograr un control preciso del movimiento de la aleación con memoria de forma (SMA.

  8. Cable Supported Bridges

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    Cable supported bridges in the form of suspension bridges and cable-stayed bridges are distinguished by their ability to overcome large spans.The book concentrates on the synthesis of cable supported bridges, covering both design and construction aspects. The analytical part covers simple methods...... to quantify the different structural configurations and allows a preliminary optimization of the main structure.Included are the most recent advances in structural design, corrosion protection of cables, aerodynamic safety, and erection procedures....

  9. Molds for cable dielectrics

    Science.gov (United States)

    Roose, L.D.

    1996-12-10

    Molds for use in making end moldings for high-voltage cables are described wherein the dielectric insulator of a cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. 5 figs.

  10. Cable Aerodynamic Control

    DEFF Research Database (Denmark)

    Kleissl, Kenneth

    This dissertation investigates the possibility of preventing wind-induced cable vibrations on cable-stayed bridges using passive aerodynamic means in the form of cable surface modifications. Especially the phenomenon of rainwind induced vibrations, which is known as the most common type of these ......This dissertation investigates the possibility of preventing wind-induced cable vibrations on cable-stayed bridges using passive aerodynamic means in the form of cable surface modifications. Especially the phenomenon of rainwind induced vibrations, which is known as the most common type...... to a categorization of the different control technics together with an identification of two key mechanisms for reduction of the design drag force. During this project extensive experimental work examining the aerodynamics of the currently used cable surface modifications together with new innovative proposals have...

  11. Cable Tester Box

    Science.gov (United States)

    Lee, Jason H.

    2011-01-01

    Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

  12. Optical Cable Design

    Science.gov (United States)

    Aggarwal, I. D.

    1984-08-01

    Optical cable applications can be divided into four major market segments. These are telecommunication, data, video and military communication. For the majority of the telecommunication, data, and video applications, a loose tube or loose ribbon design can be manufactured without incurring a microbending loss penalty. Fibre performance in the loose tube cables can be maximized by optimizing the lay length, tube dimension and pitch diameter. At present, high quality cables using both single and multimode fibre are being manufactured in volume with no additional microbending loss. For example, single and multimode cables with loss of 0.5 dB/km 1300 nm and very high bandwidths or low dispersion have been successfully installed in many cities. An example of this cable is shown in Figure 1. These cables have been used for direct buried, duct system, aerial or underwater installations.

  13. Cable suspended windmill

    Science.gov (United States)

    Farmer, Moses G. (Inventor)

    1990-01-01

    A windmill is disclosed which includes an airframe having an upwind end and a downwind end. The first rotor is rotatably connected to the airframe, and a generator is supported by the airframe and driven by the rotor. The airframe is supported vertically in an elevated disposition by poles which extend vertically upwardly from the ground and support cables which extend between the vertical poles. Suspension cables suspend the airframe from the support cable.

  14. Electrical power cable engineering

    CERN Document Server

    Thue, William A

    2011-01-01

    Fully updated, Electrical Power Cable Engineering, Third Edition again concentrates on the remarkably complex design, application, and preparation methods required to terminate and splice cables. This latest addition to the CRC Press Power Engineering series covers cutting-edge methods for design, manufacture, installation, operation, and maintenance of reliable power cable systems. It is based largely on feedback from experienced university lecturers who have taught courses on these very concepts.The book emphasizes methods to optimize vital design and installation of power cables used in the

  15. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  16. Automated Cable Preparation for Robotized Stator Cable Winding

    Directory of Open Access Journals (Sweden)

    Erik Hultman

    2017-04-01

    Full Text Available A method for robotized cable winding of the Uppsala University Wave Energy Converter generator stator has previously been presented and validated. The purpose of this study is to present and validate further developments to the method: automated stand-alone equipment for the preparation of the winding cables. The cable preparation consists of three parts: feeding the cable from a drum, forming the cable end and cutting the cable. Forming and cutting the cable was previously done manually and only small cable drums could be handled. Therefore the robot cell needed to be stopped frequently. The new equipment was tested in an experimental robot stator cable winding setup. Through the experiments, the equipment was validated to be able to perform fully automated and robust cable preparation. Suggestions are also given on how to further develop the equipment with regards to performance, robustness and quality. Hence, this work represents another important step towards demonstrating completely automated robotized stator cable winding.

  17. Multistrand superconductor cable

    Science.gov (United States)

    Borden, Albert R.

    1985-01-01

    Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.

  18. Robotic Arm Biobarrier Cable

    Science.gov (United States)

    2008-01-01

    This image, taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander on the 14th Martian day of the mission (June 7, 2008), shows the cable that held the Robotic Arm's biobarrier in place during flight has snapped. The cable's springs retracted to release the biobarrier right after landing. To the lower right of the image a spring is visible. Extending from that spring is a length of cable that snapped during the biobarrier's release. A second spring separated from the cable when it snapped and has been photographed on the ground under the lander near one of the legs. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  19. AC Cable: Yokohama Project

    Science.gov (United States)

    Masuda, Takato

    High Temperature Superconducting (HTS) cables can transmit large amounts of electricity in a compact size with minimal losses. Therefore, they are expected to save the construction cost of underground lines in urban areas and decrease transmission losses. Several HTS cables have recently been demonstrated in networks around the world, and full-scale commercialization is expected in the near future. In Japan, the development of compact HTS cables suitable for urban deployment has been underway since the early 1990s. In 2007, a national project was started to verify their operational performance and long-term reliability in the grid. An HTS cable 240 m long was installed at the Asahi substation of the Tokyo Electric Power Company (TEPCO) in Yokohama; then a joint, terminations and cooling system was constructed in 2011. After successful performance tests, the cable was connected to the grid for the first time in Japan, and started to deliver electricity to 70,000 households in October 2012. This trouble-free in-grid service continued for over a year. We can conclude that the HTS cable system performs well and has the stability required for long-term in-grid operations.

  20. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  1. VT Cable Modem Systems 2013

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013. This data...

  2. VT Cable Modem Systems 2007

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2007) includes lines depicting the extent of Vermont's cable modem broadband system as of 12/31/2007. This...

  3. VT Cable Modem Systems 2005

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2005) includes lines depicting the extent of Vermont's cable modem broadband system as of 12/31/2005. This...

  4. Economical Aspects of Superconducting Cable

    Science.gov (United States)

    Ohya, Masayoshi

    High-temperature superconducting (HTS) cables are expected to resolve technical problems with power grids because they put large-capacity, low-loss power transmission into a compact package. One problem is replacing old 275-kV oil filled (OF) cables with cross-linked polyethylene insulated vinyl sheath cables (XLPE cables). This is difficult because XLPE cable has a lower transmission capacity than OF cable. In addition, the high concentration of public infrastructure underground makes it extremely difficult to build new ones. However, if 66-kV HTS cables can be installed inside existing underground conduits and can achieve a power capacity equivalent to conventional 275-kV cables, construction costs could be significantly reduced. Moreover, if XLPE cables are used for a 1,000 MVA-class transmission line, then three circuits of nine 275-kV single-core cables would be required, which would incur a transmission loss of 90 W/m/cct. Three circuits of three 66-kV Three-in-One HTS cables, however, with an AC loss of 1 W/m/ph@3 kA, heat invasion of 2 W/m, and cooling system efficiency of 0.1, would reduce transmission loss to less than three-fifths that of XLPE cables.

  5. High Temperature Superconducting Underground Cable

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, Roger, A.

    2010-02-28

    The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

  6. The Danish Superconducting Cable Project

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1997-01-01

    The design and construction of a superconducting cable is described. The cable has a room temperature dielectric design with the cryostat placed inside the electrical insulation.BSCCO 2223 superconducting tapes wound in helix form around a former are used as the cable conductor. Results from...

  7. The Coaxial Cable

    Indian Academy of Sciences (India)

    metal pipe you see direct proof that electromagnetic energy does propagate through a tube. Light is an electromagnetic wave! Then why do cable TV operators put in an inner wire? To find the answer, we need to write down all the relevant equations and solve them. This looks like a problem in calculus, but, as you will see, ...

  8. Exceptional Cable Television.

    Science.gov (United States)

    Hunt, Edmund B.; Reid, John E., Jr.

    1987-01-01

    Ways in which the resources of a university's special education, communication arts, and library services can be combined with those of special education consortiums or parent organizations to provide exceptional children and their parents and teachers with high-quality cable educational television programs that meet their varied needs are…

  9. Development of inspection robots for bridge cables.

    Science.gov (United States)

    Yun, Hae-Bum; Kim, Se-Hoon; Wu, Liuliu; Lee, Jong-Jae

    2013-01-01

    This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented.

  10. Development of Inspection Robots for Bridge Cables

    Directory of Open Access Journals (Sweden)

    Hae-Bum Yun

    2013-01-01

    Full Text Available This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented.

  11. Method to improve superconductor cable

    Science.gov (United States)

    Borden, A.R.

    1984-03-08

    A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

  12. Cable networks, services, and management

    CERN Document Server

    2015-01-01

    Cable Networks, Services, and Management is the first book to cover cable networks, services, and their management, in-depth, for network operators, engineers, researchers, and students. Thirteen experts in various fields have contributed their knowledge of network architectures and services, Operations, Administration, Maintenance, Provisioning, Troubleshooting (OAMPT) for residential and business services, cloud, Software Defined Networks (SDN), as well as virtualization concepts and their applications as part of the future directions of cable networks. The book begins by introducing architecture and services for Data Over Cable Service Interface Specification (DOCSIS) 3.0/ 3.1, Converged Cable Access Platform (CCAP), Content Distribution Networks (CDN, IP TV, and Packet Cable and Wi-Fi for Residential Services. Topics that are discussed in proceeding chapters include: operational systems and management architectures, service orders, provisioning, fault manageme t, performance management, billing systems a...

  13. Non-Intrusive Cable Tester

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.

  14. Dynamic testing of cable structures

    Directory of Open Access Journals (Sweden)

    Caetano Elsa

    2015-01-01

    Full Text Available The paper discusses the role of dynamic testing in the study of cable structures. In this context, the identification of cable force based on vibration measurements is discussed. Vibration and damping assessment are then introduced as the focus of dynamic monitoring systems, and particular aspects of the structural behaviour under environmental loads are analysed. Diverse application results are presented to support the discussion centred on cable-stayed bridges, roof structures, a guyed mast and a transmission line.

  15. Electromagnetic transients in power cables

    CERN Document Server

    da Silva, Filipe Faria

    2013-01-01

    From the more basic concepts to the most advanced ones where long and laborious simulation models are required, Electromagnetic Transients in Power Cables provides a thorough insight into the study of electromagnetic transients and underground power cables. Explanations and demonstrations of different electromagnetic transient phenomena are provided, from simple lumped-parameter circuits to complex cable-based high voltage networks, as well as instructions on how to model the cables.Supported throughout by illustrations, circuit diagrams and simulation results, each chapter contains exercises,

  16. Motility of electric cable bacteria

    DEFF Research Database (Denmark)

    Bjerg, Jesper Tataru; Damgaard, Lars Riis; Holm, Simon Agner

    2016-01-01

    Cable bacteria are filamentous bacteria that electrically couple sulfide oxidation and oxygen reduction at centimeter distances, and observations in sediment environments have suggested that they are motile. By time-lapse microscopy, we found that cable bacteria used gliding motility on surfaces...

  17. Cable Bacteria in Freshwater Sediments

    DEFF Research Database (Denmark)

    Risgaard-Petersen, Nils; Kristiansen, Michael; Frederiksen, Rasmus

    2015-01-01

    In marine sediments cathodic oxygen reduction at the sediment surface can be coupled to anodic sulfide oxidation in deeper anoxic layers through electrical currents mediated by filamentous, multicellular bacteria of the Desulfobulbaceae family, the so-called cable bacteria. Until now, cable...... bacteria have only been reported from marine environments. In this study, we demonstrate that cable bacteria also occur in freshwater sediments. In a first step, homogenized sediment collected from the freshwater stream Giber Å, Denmark, was incubated in the laboratory. After 2 weeks, pH signatures...... marine cable bacteria, with the genus Desulfobulbus as the closest cultured lineage. The results of the present study indicate that electric currents mediated by cable bacteria could be important for the biogeochemistry in many more environments than anticipated thus far and suggest a common evolutionary...

  18. Length of a Hanging Cable

    Directory of Open Access Journals (Sweden)

    Eric Costello

    2011-01-01

    Full Text Available The shape of a cable hanging under its own weight and uniform horizontal tension between two power poles is a catenary. The catenary is a curve which has an equation defined by a hyperbolic cosine function and a scaling factor. The scaling factor for power cables hanging under their own weight is equal to the horizontal tension on the cable divided by the weight of the cable. Both of these values are unknown for this problem. Newton's method was used to approximate the scaling factor and the arc length function to determine the length of the cable. A script was written using the Python programming language in order to quickly perform several iterations of Newton's method to get a good approximation for the scaling factor.

  19. 10BASE5 Ethernet Cable & Vampire Tap

    CERN Multimedia

    1983-01-01

    10BASE5 Thick Ethernet Cable, 10Mbit/sec. In the 1980s and early 1990's, Ethernet became more popular and provided a much faster data transmission rate. This cable is one of the first ethernet cables from 1983, a thick, bulky affair. Computers were attached via "Vampire Taps" which were connectors screwed straight through the shielding of the cable.

  20. 14 CFR 27.1365 - Electric cables.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat...

  1. Thermal analysis of underground power cable system

    Science.gov (United States)

    Rerak, Monika; Ocłoń, Paweł

    2017-10-01

    The paper presents the application of Finite Element Method in thermal analysis of underground power cable system. The computations were performed for power cables buried in-line in the ground at a depth of 2 meters. The developed mathematical model allows determining the two-dimensional temperature distribution in the soil, thermal backfill and power cables. The simulations studied the effect of soil and cable backfill thermal conductivity on the maximum temperature of the cable conductor. Also, the effect of cable diameter on the temperature of cable core was studied. Numerical analyses were performed based on a program written in MATLAB.

  2. Air flow around suspended cables

    Science.gov (United States)

    Gołębiowska, Irena; Dutkiewicz, Maciej

    The impact of wind on construction structures is essential issue in design and operation. In particular, the wind can cause the dengerous vibrations of slender structures with low rigidity, eg. vibrations of cables of suspension and cable-stayed bridges or high voltage transmision lines, thus understanding of wind flow around such constructions is significant. In the paper the results of the analysis of wind flow around the cables for different Reynolds number is presented. The analysed flow meets the Navier-Stokes and continuity equations. The circle and elipse section of the cable is analysed. The discusion of vorticity, drag and lift coefficients and cases due to different angle of wind flow action is presented. The boundary layer and its infuence on total flow is analysed.

  3. Air flow around suspended cables

    Directory of Open Access Journals (Sweden)

    Gołębiowska Irena

    2017-01-01

    Full Text Available The impact of wind on construction structures is essential issue in design and operation. In particular, the wind can cause the dengerous vibrations of slender structures with low rigidity, eg. vibrations of cables of suspension and cable-stayed bridges or high voltage transmision lines, thus understanding of wind flow around such constructions is significant. In the paper the results of the analysis of wind flow around the cables for different Reynolds number is presented. The analysed flow meets the Navier-Stokes and continuity equations. The circle and elipse section of the cable is analysed. The discusion of vorticity, drag and lift coefficients and cases due to different angle of wind flow action is presented. The boundary layer and its infuence on total flow is analysed.

  4. Motility of electric cable bacteria

    DEFF Research Database (Denmark)

    Bjerg, Jesper Tataru; Damgaard, Lars Riis; Holm, Simon Agner

    2016-01-01

    Cable bacteria are filamentous bacteria that electrically couple sulfide oxidation and oxygen reduction at centimeter distances, and observations in sediment environments have suggested that they are motile. By time-lapse microscopy, we found that cable bacteria used gliding motility on surfaces...... with a highly variable speed of 0.50.3 ms1 (meanstandard deviation) and time between reversals of 155108 s. They frequently moved forward in loops, and formation of twisted loops revealed helical rotation of the filaments. Cable bacteria responded to chemical gradients in their environment, and around the oxic......-anoxic interface, they curled and piled up, with straight parts connecting back to the source of sulfide. Thus, it appears that motility serves the cable bacteria in establishing and keeping optimal connections between their distant electron donor and acceptors in a dynamic sediment environment....

  5. Cable SGEMP Code Validation Study

    Energy Technology Data Exchange (ETDEWEB)

    Ballard, William Parker [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Center for CA Weapons Systems Engineering

    2013-05-01

    This report compared data taken on the Modular Bremsstrahlung Simulator using copper jacketed (cujac) cables with calculations using the RHSD-RA Cable SGEMP analysis tool. The tool relies on CEPXS/ONBFP to perform radiation transport in a series of 1D slices through the cable, and then uses a Green function technique to evaluate the expected current drive on the center conductor. The data were obtained in 2003 as part of a Cabana verification and validation experiment using 1-D geometries, but were not evaluated until now. The agreement between data and model is not adequate unless gaps between the dielectric and outer conductor (ground) are assumed, and these gaps are large compared with what is believed to be in the actual cable.

  6. Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables

    Directory of Open Access Journals (Sweden)

    Xu Xie

    2014-06-01

    Full Text Available In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance.

  7. An overview of the ITER cabling network and cable database management

    Energy Technology Data Exchange (ETDEWEB)

    Sonara, Jashwant, E-mail: jashwant.Sonara@iter.org [ITER Organization, Route de Vinon sur Verdon, CS 90 046-13067, Saint Paul Lez Durance (France); Beltran, David; Pintea, Bogdan; Hourtoule, Joel; Benfatto, Ivone [ITER Organization, Route de Vinon sur Verdon, CS 90 046-13067, Saint Paul Lez Durance (France); Kim, Sung Hoon; Lee, Kun Ho; Jung, Sun Kyung; Lee, Cheoung-Joon [KEPCO E& C, Yonggudaero, Giheung-gu, Yongin-si, Gyeonggi-do, 446-713 (Korea, Republic of)

    2015-10-15

    Highlights: • More than 80,000 cables have been registered into ITER centralized cable database. • This cabling represents 28 ITER plant systems and 21,000 equipments including 61,000 non-safety cables and 7300 safety cables. • Development of unique cable engineering management system for diversified cabling requirement. • Use of 2D and 3D softwares and integration of both softwares into bespoke software which can handle 2D and 3D features of the tray network. - Abstract: ITER is a nuclear fusion facility, where many systems with varying functional and physical characteristics coexist. This makes the cabling requirements diverse too. The design of the ITER demands extensive integration of many systems interfaces. This process starts by collating cable requirement data to form a giant cable database with scope for approximately 120,000 cables in total. Ultimately the cabling installation will be approximately twice the size of one required for a 3rd generation nuclear fission power plant, with cables spanning more than 12,000 km to be installed within approximately 200 km of cable trays. Considering the differing cabling requirements, the raceway network and cables shall be routed in a prescribed manner to comply with French Nuclear Safety standards. This paper describes an overview of the ITER cabling network, the cable engineering design workflow, development and management of the cable database and integration between the software tools.

  8. ELECTROSTATIC PROCESSES IN POWER CABLES

    Directory of Open Access Journals (Sweden)

    G.V. Bezprozvannych

    2013-09-01

    Full Text Available Observation of contact electrification of power cable samples is made. It is revealed that the contact potential difference and the capacity formed under separation of free charges on the surfaces of the contacting materials depend on cable design, applied materials, and inspection schemes. Time series of capacity drift and dielectric loss tangent caused by instability of triboelectric charging of the contacting surfaces are presented.

  9. Cable Driven Devices for Telemanipulation

    OpenAIRE

    Ferraresi, Carlo; Pescarmona, Francesco

    2010-01-01

    Cable driven robotic devices present peculiar aspects, requiring the solution of very specific problems. As regards the determination of the main operational characteristics, like the workspace, it is necessary to consider that such devices are often parallel and redundant structures. Moreover, cables can only exert traction forces. As a consequence, the development of such structures requires coping with two main aspects: (a) the solution of forward kinematics and inverse statics, necessary ...

  10. Optical Measurement of Cable and String Vibration

    Directory of Open Access Journals (Sweden)

    Y. Achkire

    1998-01-01

    Full Text Available This paper describes a non contacting measurement technique for the transverse vibration of small cables and strings using an analog position sensing detector. On the one hand, the sensor is used to monitor the cable vibrations of a small scale mock-up of a cable structure in order to validate the nonlinear cable dynamics model. On the other hand, the optical sensor is used to evaluate the performance of an active tendon control algorithm with guaranteed stability properties. It is demonstrated experimentally, that a force feedback control law based on a collocated force sensor measuring the tension in the cable is feasible and provides active damping in the cable.

  11. Static and Dynamic Mechanical Properties of Long-Span Cable-Stayed Bridges Using CFRP Cables

    Directory of Open Access Journals (Sweden)

    Mei Kuihua

    2017-01-01

    Full Text Available The elastic modulus and deadweight of carbon fiber-reinforced polymer (CFRP cables are different from those of steel cables. Thus, the static and dynamic behaviors of cable-stayed bridges using CFRP cables are different from those of cable-stayed bridges using steel cables. The static and dynamic performances of the two kinds of bridges with a span of 1000 m were studied using the numerical method. The effects of geometric nonlinear factors on static performance of the two kinds of cable-stayed bridges were analyzed. The live load effects and temperature effects of the two cable-stayed bridges were also analyzed. The influences of design parameters, including different structural systems, the numbers of auxiliary piers, and the space arrangement types of cable, on the dynamic performance of the cable-stayed bridge using CFRP cables were also studied. Results demonstrate that sag effect of the CFRP cable is much smaller than that of steel cable. The temperature effects of CFRP cable-stayed bridge are less than those of steel cable-stayed bridge. The vertical bending natural vibration frequency of the CFRP cable-stayed bridge is generally lower than that of steel cable-stayed bridge, whereas the torsional natural vibration frequency of the former is higher than that of the latter.

  12. Data Base On Cables And Connectors

    Science.gov (United States)

    Bowen, Arlen R.; Oliver, John D.

    1995-01-01

    Report describes Connector Adapter Cable Information Data Base (CONNAID) computer program, managing data base containing necessary information concerning electrical connectors, breakout boxes, adapter cables, backshells, and pertinent torque specifications for engineering project.

  13. Equalization of data transmission cable

    Science.gov (United States)

    Zobrist, G. W.

    1975-01-01

    The paper describes an equalization approach utilizing a simple RLC network which can obtain a maximum slope of -12dB/octave for reshaping the frequency characteristics of a data transmission cable, so that data may be generated and detected at the receiver. An experimental procedure for determining equalizer design specifications using distortion analysis is presented. It was found that for lengths of 16 PEV-L cable of up to 5 miles and data transmission rates of up to 1 Mbs, the equalization scheme proposed here is sufficient for generation of the data with acceptable error rates.

  14. Online Cable Tester and Rerouter

    Science.gov (United States)

    Lewis, Mark; Medelius, Pedro

    2012-01-01

    Hardware and algorithms have been developed to transfer electrical power and data connectivity safely, efficiently, and automatically from an identified damaged/defective wire in a cable to an alternate wire path. The combination of online cable testing capabilities, along with intelligent signal rerouting algorithms, allows the user to overcome the inherent difficulty of maintaining system integrity and configuration control, while autonomously rerouting signals and functions without introducing new failure modes. The incorporation of this capability will increase the reliability of systems by ensuring system availability during operations.

  15. Trenchless Replacement of Buried Cable Lines

    Directory of Open Access Journals (Sweden)

    Hans-Joachim Bayer

    2007-01-01

    Full Text Available An enormous amount of underground electricity and telecommunication cables have been worn over the time with technical defects or need capacity increases. Thus, new lines need to be installed. In urban areas, even in smaller communities and in natural reserves, open trenching is difficult and often not permitted.In response, new patented methods of trenchless cable replacement using the HDD equipment have been developed by the TT Group. The new technology is called “Wash-over-cable-replacement” and applies specially designed drill heads, cutting around the old cable string in various configurations (completely closed, U-shape or S-shape embracing, depending to the coating type of the old cable. This special cable replacement drill head separates the cable from the surrounding adhesive soil or the sand bedding by creating a very small annular space around the cable thus enabling the pulling or dragging out of the old cable section between the start and the exit pit. After the old cable has been loosened from the surrounding soil by means of the wash over process and pulled out, the new cable can be smoothly pulled into the void using the drill rods and embedding the new cable in a rich bed of Bentonite.The wash-over drill heads are slim and have inner and outer nozzles for Bentonite and bits to handle roots, pebbles, gravel and the like. These drill heads perform very quickly (up to 3 meters per minute to effectively wash over existing cables without damaging the cable coating and prepare the ground for a fast new laying of a new cable in the existing line. Network owners also benefit from the fact that new geodetic or topographic surveys and documentations of the new cable are not necessary. Only the documents, remarks, technical codes and existing geodetic data need to be updated.The paper will outline the technological background and include several practical job examples.

  16. North American Submarine Cable Association (NASCA) Submarine Cables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data show the locations of in-service and out-of-service submarine cables that are owned by members of NASCA and located in U.S. territorial waters. More...

  17. Integrated Cable System Aging Management Guidance: Low-Voltage Cable

    Energy Technology Data Exchange (ETDEWEB)

    Denny, W M

    2003-01-02

    The document provides insights into common aging issues and symptoms and includes pictures and descriptions of deterioration that is observable. The report provides a rapid review of the important information necessary to assess the aging of the low-voltage cable system used in nuclear power plants.

  18. Using Cable Television for Library Data Transmission.

    Science.gov (United States)

    Whitaker, Douglas A.

    1985-01-01

    Discusses information gained from a test of cable data circuits on a Geac bibliographic control system at the Wayne Oakland Library Federation (WOLF) (Michigan). Highlights include an introduction to cable, hardware profile, the WOLF experience, and key questions that will affect the future use of cable for data transmission. (EJS)

  19. Cable Television and Satellite Broadcasting

    Science.gov (United States)

    1990-05-31

    homes by the end teevision per week. However, accorigtthIne op that de a ay anthr 4 million hoesby - tohoe pendent Broadcast Authority’s (IBA...France to create a leisure desire to buy cable TV. park and a production studio for cartoons. 8 The Role of Public Service Providers In the Next Decade

  20. Power applications for superconducting cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Hansen, Steen; Jørgensen, Preben

    2000-01-01

    High temperature superconducting (HTS) cables for use in electric ac power systems are under development around the world today. There are two main constructions under development: the room temperature dielectric design and the cryogenic dielectric design. However, theoretical studies have shown...

  1. Offshore Cable Installation - Lillgrund. Lillgrund Pilot Project

    Energy Technology Data Exchange (ETDEWEB)

    Unosson, Oscar (Vattenfall Vindkraft AB, Stockholm (Sweden))

    2009-01-15

    This report describes the installation method and the experiences gained during the installation of the submarine cables for the offshore wind farm at Lillgrund. The wind farm consists of 48 wind turbines and is expected to produce 0.33 TWh annually. Different aspects of the installation, such as techniques, co-operation between the installation teams, weather conditions and regulatory and environmental issues are described in this report. In addition, recommendations and guidelines are provided, which hopefully can be utilised in future offshore wind projects. The trenches, in which the submarine cables were laid, were excavated weeks before the cable laying. This installation technique proved to be successful for the laying of the inter array cables. The export cable, however, was laid into position with difficulty. The main reason why the laying of the export cable proved more challenging was due to practical difficulties connected with the barge entrusted with the cable laying, Nautilus Maxi. The barge ran aground a number of times and it had difficulties with the thrusters, which made it impossible to manoeuvre. When laying the inter array cables, the method specification was closely followed, and the laying of the cables was executed successfully. The knowledge and experience gained from the offshore cable installation in Lillgrund is essential when writing technical specifications for new wind plant projects. It is recommended to avoid offshore cable installation work in winter seasons. That will lower the chances of dealing with bad weather and, in turn, will reduce the risks

  2. Parallel monostrand stay cable bending fatigue

    DEFF Research Database (Denmark)

    Winkler, Jan Pawel

    of a cable stayed bridge. Characterization of a bridge monitoring data is shown and a generic method for the analysis of a cable fatigue in cable supported bridge structure is proposed. With this research, one of the most basic oversights in the lifetime assessment of cablesupported structures, namely......This dissertation investigates the bending fatigue response of high-strength steel monostrands and multistrand stay cables to cyclic transverse deformations. Increasing bridge stock numbers and a push for longer cable-supported span lengths have led to an increased number of reported incidents...... of damage and replacement of bridge stay cables due to wind and traffic-induced fatigue. The understanding of fatigue mechanisms in most steel structures is well established. However, in the case of cables composed of steel strands, many important aspects related with bending fatigue remain to be clarified...

  3. Tubing and cable cutting tool

    Science.gov (United States)

    Mcsmith, D. D.; Richardson, J. I. (Inventor)

    1984-01-01

    A hand held hydraulic cutting tool was developed which is particularly useful in deactivating ejection seats in military aircraft rescue operations. The tool consists primarily of a hydraulic system composed of a fluid reservoir, a pumping piston, and an actuator piston. Mechanical cutting jaws are attached to the actuator piston rod. The hydraulic system is controlled by a pump handle. As the pump handle is operated the actuator piston rod is forced outward and thus the cutting jaws are forced together. The frame of the device is a flexible metal tubing which permits easy positioning of the tool cutting jaws in remote and normally inaccessible locations. Bifurcated cutting edges ensure removal of a section of the tubing or cable to thereby reduce the possibility of accidental reactivation of the tubing or cable being severed.

  4. Initial tension loss in cerclage cables.

    Science.gov (United States)

    Ménard, Jérémie; Émard, Maxime; Canet, Fanny; Brailovski, Vladimir; Petit, Yvan; Laflamme, George Y

    2013-10-01

    Cerclage cables, frequently used in the management of fractures and osteotomies, are associated with a high failure rate and significant loosening during surgery. This study compared the capacity to maintain tension of different types of orthopaedic cable systems. Multifilament Cobalt-Chrome (CoCr) cables with four different crimp/clamp devices (DePuy, Stryker, Zimmer and Smith&Nephew) and one non-metallic Nylon (Ny) cable from Kinamed were instrumented with a load cell to measure tension during insertion. Significant tension loss was observed with crimping for all cables (Ptensioner led to an additional unexpected tension loss (CoCr-DePuy: 18%, CoCr-Stryker: 29%, CoCr-Smith&Nephew: 33%, Ny: 46%, and CoCr-Zimmer: 52%). The simple CoCr (DePuy) cable system outperformed the more sophisticated locking devices due to its significantly better ability to prevent tension loss. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Field application of a cable NDT system for cable-stayed bridge using MFL sensors integrated

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Choi, Jun Sung; Park, Seung Hee [Sungkyunkwan University, Seoul (Korea, Republic of); Lee, Eun Chan [Korea Maintance Co., Ltd., Seoul (Korea, Republic of)

    2014-02-15

    In this study, an automated cable non-destructive testing(NDT) system was developed to monitor the steel cables that are a core component of cable-stayed bridges. The magnetic flux leakage(MFL) method, which is suitable for ferromagnetic continuum structures and has been verified in previous studies, was applied to the cable inspection. A multi-channel MFL sensor head was fabricated using hall sensors and permanent magnets. A wheel-based cable climbing robot was fabricated to improve the accessibility to the cables, and operating software was developed to monitor the MFL-based NDT research and control the climbing robot. Remote data transmission and robot control were realized by applying wireless LAN communication. Finally, the developed element techniques were integrated into an MFL-based cable NDT system, and the field applicability of this system was verified through a field test at Seohae Bridge, which is a typical cable-stayed bridge currently in operation.

  6. Fatigue of cable anchorage of large cable stayed bridge; Daikibo shachokyo cable teichaku kozo no hiro

    Energy Technology Data Exchange (ETDEWEB)

    Endo, T.; Matsumoto, T. [Honshu-Shikoku Bridge Authority, Tokyo (Japan); Tsukahara, H. [Yokogawa Bridge Corp., Tokyo (Japan); Miki, C. [Tokyo Institute of Technology, Tokyo (Japan)

    1995-10-21

    Design considerations such as design schemes, the assemblage and welding of steel plates, and safety for fatigue of welded connections have to be taken for the cable anchorages of the steel cable stayed bridges. In this study, two full scale models, which have different shape of box anchorages welded to the web of the main girder, were made to investigate fatigue characteristics as well as assemblage of plate and gelding details. Finite element analyses for both test models and actual bridges here carried out to compare stress distribution. It was confirmed that the assemblage and welding of both types of box anchorage were attainable kith required quality and accuracy. According to the fatigue test, fatigue cracks originated from the weldings of the bearing plate to which the load from cable socket applied directly were caused by out-of-plane bending of the bearing plate. It was proved that the slight modifications of the details around the bearing plate resulted in sufficient fatigue strength in both types of anchorage. 1 ref., 23 figs., 2 tabs.

  7. How do you like them cables?

    CERN Multimedia

    Sergei Malyukov

    Cabling work is not for clautrophobic people! Cables are like the blood vessels and nervous system of ATLAS. With the help of all these cables, we can power ATLAS, control the detector and read out the data. Like the human blood vessels, they penetrate inside the ATLAS volume, reaching each of its elements. The ATLAS developers started to think about design of services, cables and pipes at the very first stages of the project. The cabling project has been developing most intensively during the last five years, passing through the projection and CAD design phases, then the installation of cable trays and finally the cables. The cable installation itself took two and a half years and was done by teams of technicians from several institutes from Russia, the Czech Republic and Poland. Here are some numbers to illustrate the scale of the ATLAS cabling system. More than 25000 optical fiber channels are used for reading the information from the sub-detectors and delivering the timing signals. The total numbe...

  8. Managing cable thermal stress through predictive ratings

    OpenAIRE

    Huang, R.; Pilgrim, J.A.; Lewin, P.L.; Scott, D.; Morrice, D.

    2015-01-01

    The majority of high voltage cables are sized and operated by a continuous current rating which is based on the worst-case assumptions. However, the load on the cables themselves may vary significantly depending upon the time and season. In this paper, a dynamic thermal model for a cable in air installation is built using the finite difference method. The real-time load current and ambient conditions are accessible to allow improved cable modelling. This model is then used to support the rati...

  9. Cable fire tests in France

    Energy Technology Data Exchange (ETDEWEB)

    Kaercher, M. [Electricite de France (EDF), 69 - Villeurbanne (France)

    2000-05-01

    Modifications are being carried out in all French nuclear power plants to improve fire safety. These modifications are based on a three level defense in depth concept: fire preventing, fire containing and fire controlling. Fire containing requires many modifications such as protection of cable races and assessment of fire propagation which both need R and D development. On one hand, cable wraps made with mineral wool were tested in all configurations including effect of aging, overheating and fire and qualified for the use as protection from common failure modes. On the other hand, cables races in scale one were subject to gas burner or solvent pool fire to simulate ignition and fire propagation between trays and flash over situations. These tests have been performed under several typical lay out conditions. The results of the tests can be used as input data in computer modelling for validation of fire protection measures. (orig.) [German] Modifikationen werden in allen franzoesischen Kernkraftwerken durchgefuehrt, um die Brandschutzsicherung zu verbessern. Die Modifikationen sind auf einem Dreistufenkonzept begruendet: brandvorbeugende Massnahmen, begrenzter Brandschutz und Brandkontrolle. Begrenzter Brandschutz verlangt viele Modifikationen wie Brandschutz von Kabelanlagen und Kenntnisse ueber Feuerentwicklung, die Forschung und Entwicklung brauchen. Einerseits werden die aus Mineralwolle hergestellten Kabelhuellen fuer alle moeglichen Faelle geprueft, einschliesslich der Auswirkung von Alterung, Ueberhitzung und Feuer, um so die Huellen als Schutz zu nutzen. Andererseits werden Kabelanlagen der Stufe eins mit Gas und Loesungsmitteln entzuendet, um Entzuendung, Feuerentwicklung und Feueruebersprung zu simulieren. Diese Versuche werden unter unterschiedlichen Anlagenbedingungen durchgefuehrt. Die Ergebnisse koennen fuer Computermodelle zur Pruefung von Brandschutztechniken benutzt werden. (orig.)

  10. POTS to broadband ... cable modems.

    Science.gov (United States)

    Kabachinski, Jeff

    2003-01-01

    There have been 3 columns talking about broadband communications and now at the very end when it's time to compare using a telco or cableco, I'm asking does it really matter? So what if I can actually get the whole 30 Mbps with a cable network when the website I'm connecting to is running on an ISDN line at 128 Kbps? Broadband offers a lot more bandwidth than the connections many Internet servers have today. Except for the biggest websites, many servers connect to the Internet with a switched 56-Kbps, ISDN, or fractional T1 line. Even with the big websites, my home network only runs a 10 Mbps Ethernet connection to my cable modem. Maybe it doesn't matter that the cable lines are shared or that I can only get 8 Mbps from an ADSL line. Maybe the ISP that I use has a T1 line connection to the Internet so my new ADSL modem has a fatter pipe than my provider! (See table 1). It all makes me wonder what's in store for us in the future. PC technology has increased exponentially in the last 10 years with super fast processor speeds, hard disks of hundreds of gigabytes, and amazing video and audio. Internet connection speeds have failed to keep the same pace. Instead of hundreds of times better or faster--modem speeds are barely 10 times faster. Broadband connections offer some additional speed but still not comparable growth as broadband connections are still in their infancy. Rather than trying to make use of existing communication paths, maybe we need a massive infrastructure makeover of something new. How about national wireless access points so we can connect anywhere, anytime? To use the latest and fastest wireless technology you will simply need to buy another $9.95 WLAN card or download the latest super slick WLAN compression/encryption software. Perhaps it is time for a massive infra-restructuring. Consider the past massive infrastructure efforts. The telcos needed to put in their wiring infrastructure starting in the 1870s before telephones were useful to the

  11. A new multiconstraint method for determining the optimal cable stresses in cable-stayed bridges.

    Science.gov (United States)

    Asgari, B; Osman, S A; Adnan, A

    2014-01-01

    Cable-stayed bridges are one of the most popular types of long-span bridges. The structural behaviour of cable-stayed bridges is sensitive to the load distribution between the girder, pylons, and cables. The determination of pretensioning cable stresses is critical in the cable-stayed bridge design procedure. By finding the optimum stresses in cables, the load and moment distribution of the bridge can be improved. In recent years, different research works have studied iterative and modern methods to find optimum stresses of cables. However, most of the proposed methods have limitations in optimising the structural performance of cable-stayed bridges. This paper presents a multiconstraint optimisation method to specify the optimum cable forces in cable-stayed bridges. The proposed optimisation method produces less bending moments and stresses in the bridge members and requires shorter simulation time than other proposed methods. The results of comparative study show that the proposed method is more successful in restricting the deck and pylon displacements and providing uniform deck moment distribution than unit load method (ULM). The final design of cable-stayed bridges can be optimised considerably through proposed multiconstraint optimisation method.

  12. Nonlinear Analysis of Cable Vibration of a Multispan Cable-Stayed Bridge under Transverse Excitation

    Directory of Open Access Journals (Sweden)

    Kun Lin

    2014-01-01

    Full Text Available The nonlinear vibrations of cable in a multispan cable-stayed bridge subjected to transverse excitation are investigated. The MECS (multielements cable system model, where multielements per cable stay are used, is built up and used to analyze the model properties of the multispan cable-stayed bridges. Then, a simplified two-degrees-of-freedom (2-DOFs model, where the tower or the deck is reduced to a beam, is proposed to analyze the nonlinear dynamic behaviors of the beam and cable. The results of MECS model analysis show that the main tower in the multispan cable-stayed bridge is prone to the transverse vibration, and the local vibration of cables only has a little impact on the frequency values of the global modes. The results of simplified model analysis show that the energy can be transformed between the modes of the beam and cable when the nature frequencies of them are very close. On the other hand, with the transverse excitation changing, the cable can exhibit richer quasi-periodic or chaotic motions due to the nonlinear terms caused by the coupled mode between the beam and cable.

  13. A New Multiconstraint Method for Determining the Optimal Cable Stresses in Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    B. Asgari

    2014-01-01

    Full Text Available Cable-stayed bridges are one of the most popular types of long-span bridges. The structural behaviour of cable-stayed bridges is sensitive to the load distribution between the girder, pylons, and cables. The determination of pretensioning cable stresses is critical in the cable-stayed bridge design procedure. By finding the optimum stresses in cables, the load and moment distribution of the bridge can be improved. In recent years, different research works have studied iterative and modern methods to find optimum stresses of cables. However, most of the proposed methods have limitations in optimising the structural performance of cable-stayed bridges. This paper presents a multiconstraint optimisation method to specify the optimum cable forces in cable-stayed bridges. The proposed optimisation method produces less bending moments and stresses in the bridge members and requires shorter simulation time than other proposed methods. The results of comparative study show that the proposed method is more successful in restricting the deck and pylon displacements and providing uniform deck moment distribution than unit load method (ULM. The final design of cable-stayed bridges can be optimised considerably through proposed multiconstraint optimisation method.

  14. Switching Restrikes in HVAC Cable Lines and Hybrid HVAC Cable/OHL Lines

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Balle Holst, Per

    2011-01-01

    The disconnection of HV underground cables may, if unsuccessful, originate a restrike in the circuit breaker, leading to high overvoltages, and potentially damaging the cable and near equipment. Due to the cable high capacitance and low resistance the voltage damping is slow, resulting, half...... a cycle after the disconnection, in a voltage of approximately 2 pu at the circuit breaker terminals. In case of restrike in that instant, it is theoretical possible to attain an overvoltage of 3 pu. The overvoltage can be even larger in hybrid cable-Overhead Lines (OHL), due to voltage magnifications...... in the junction point. This paper explains the phenomenon for pure cable lines and hybrid cable-OHL lines, and uses Denmark’s high voltage transmission grid, as planned for the year 2030, as test system. The accuracy of different cable models, and the number of substations from the transient event requiring...

  15. Wind-induced vibration of stay cables

    Science.gov (United States)

    2007-08-01

    Cable-stayed bridges have become the form of choice over the past several decades for bridges in the medium- to long-span range. In some cases, serviceability problems involving large amplitude vibrations of stay cables under certain wind and rain co...

  16. MVAC Submarine cable, impedance measurements and analysis

    DEFF Research Database (Denmark)

    Arentsen, Martin Trolle; Pedersen, Morten Virklund; Expethit, Adrian

    2017-01-01

    Due to environmental concerns an increase in off-shore windfarms has been observed in recent years, leading to an increased demand for three-core-wire-armoured submarine cables. However, the IEC Standard 60287 used to calculate the ampacity of these cables is widely recognized as being not accurate...

  17. 30 CFR 18.45 - Cable reels.

    Science.gov (United States)

    2010-07-01

    ... constitute an integral part of a circuit for transmitting electrical energy. (d) Cable reels for shuttle cars... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.45 Cable reels. (a) A self-propelled machine, that receives electrical energy through a portable...

  18. Pay Cable: A Viable Advertising Medium?

    Science.gov (United States)

    Krugman, Dean M.; Barban, Arnold M.

    Cable television, which cannot only clarify local signals to weak signal areas but can also bring in distant signals to areas which have been receiving few signals, has the capacity to present special television programs to customers for extra fees. The number of pay cable subscribers is growing and industry projections are that it will reach 20…

  19. The Status of Cable Communications in Libraries.

    Science.gov (United States)

    Kenney, Brigitte L.

    Librarians are and will be using cable television technologies to enhance and extend their services. While questions remain in regard to the technology itself, the health and viability of the industry, and government policy, librarians are seeing cable communications as an opportunity to gain credibility and visibility, and also as an extension of…

  20. When is hardwood cable logging economical?

    Science.gov (United States)

    Chris B. LeDoux

    1985-01-01

    Using cable logging to harvest eastern hardwood logs on steep terrain can result in low production rates and high costs per unit of wood produced. Logging managers can improve productivity and profitability by knowing how the interaction of site-specific variables and cable logging equipment affect costs and revenues. Data from selected field studies and forest model...

  1. Assessment of sodium conductor distribution cable

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The study assesses the barriers and incentives for using sodium conductor distribution cable. The assessment considers environmental, safety, energy conservation, electrical performance and economic factors. Along with all of these factors considered in the assessment, the sodium distribution cable system is compared to the present day alternative - an aluminum conductor system. (TFD)

  2. Frequency Dependent Losses in Transmission Cable Conductors

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Guðmundsdóttir, Unnur Stella

    2011-01-01

    and economical gain, such severe network changes necessitate correct estimation and optimisation of load conditions in the cable grid. Both IEC and IEEE have published standards for rating transmission cables' current carrying capacity. These standards are based on assumptions of a number of parameters......, such as thermal conditions in and around the cable, as well as the heat generated in conductors, screens, armours etc., taking into account proximity and skin effects. The work performed and presented in this paper is concerned with an improved determination of the losses generated in the conductor, by means...... of better calculation of the AC resistance of transmission cable conductors, in particular regarding higher frequencies. In this way, also losses under harmonics can be covered. Furthermore, the model is suitable for modelling of transient attenuation in high voltage cables. The AC resistance is calculated...

  3. Counter-balanced, multiple cable construction crane

    Science.gov (United States)

    Mikulas, Martin M., Jr. (Inventor); Yang, Li-Farn (Inventor)

    1993-01-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  4. Nuclear power plant cable materials :

    Energy Technology Data Exchange (ETDEWEB)

    Celina, Mathias C.; Gillen, Kenneth T; Lindgren, Eric Richard

    2013-05-01

    A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostly inert aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on

  5. Wind-induced cable vibrations and countermeasures of cables of PC cable-stayed bridge. PC syachokyo keburu no kaze ni yoru shindo to sono taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M. (Kawada Industries Inc., Tokyo (Japan))

    1994-05-01

    In recent years, long span of cable-stayed bridges is remarkable. The wind-induced cable vibration called as line vibration and wake galloping was given as an important problem not only in the steel cable-stayed bridges but also in the PC cable-stayed bridges. The technical engineers in design of the cable-stayed bridges have many times to confront the problems on the vibration control of cables, it is considered that sufficient understand of the wind-induced vibration and countermeasures for cables of the PC cable-stayed bridges is necessary. Many reports on the countermeasure examples and trend of vibration control centred on cables of the cable-stayed bridges have been published. In this paper, the wind-induced vibration of cables in the cable-stayed bridges was reviewed, the examples of countermeasures of vibration control on cables in the PC cable-stayed bridges was mainly introduced. The remaining tasks and future prospects on vibration control of the PC cable-stayed bridges were described. 14 refs., 13 figs., 4 tabs.

  6. Self-healing cable for extreme environments

    Science.gov (United States)

    Huston, Dryver R. (Inventor); Tolmie, Bernard R. (Inventor)

    2009-01-01

    Self-healing cable apparatus and methods disclosed. The self-healing cable has a central core surrounded by an adaptive cover that can extend over the entire length of the self-healing cable or just one or more portions of the self-healing cable. The adaptive cover includes an axially and/or radially compressible-expandable (C/E) foam layer that maintains its properties over a wide range of environmental conditions. A tape layer surrounds the C/E layer and is applied so that it surrounds and axially and/or radially compresses the C/E layer. When the self-healing cable is subjected to a damaging force that causes a breach in the outer jacket and the tape layer, the corresponding localized axially and/or radially compressed portion of the C/E foam layer expands into the breach to form a corresponding localized self-healed region. The self-healing cable is manufacturable with present-day commercial self-healing cable manufacturing tools.

  7. Non-linear stochastic response of a shallow cable

    DEFF Research Database (Denmark)

    Larsen, Jesper Winther; Nielsen, Søren R.K.

    2004-01-01

    The paper considers the stochastic response of geometrical non-linear shallow cables. Large rain-wind induced cable oscillations with non-linear interactions have been observed in many large cable stayed bridges during the last decades. The response of the cable is investigated for a reduced two...

  8. Choice Of Computer Networking Cables And Their Effect On Data ...

    African Journals Online (AJOL)

    Computer networking is the order of the day in this Information and Communication Technology (ICT) age. Although a network can be through a wireless device most local connections are done using cables. There are three main computer-networking cables namely coaxial cable, unshielded twisted pair cable and the optic ...

  9. 46 CFR 111.60-4 - Minimum cable conductor size.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-4 Minimum cable conductor size. Each cable conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...

  10. Multiconductor Short/Open Cable Tester

    Science.gov (United States)

    Eichenberg, Dennis

    1994-01-01

    Frequent or regular testing of multiconductor cables terminated in multipin conductors tedious, if not impossible, task. This inexpensive circuit simplifies open/short testing and is amenable to automation. In operation, pair of connectors selected to match pair of connectors installed on each of cables to be tested. As many connectors accommodated as required, and each can have as many conductors as required. Testing technique implemented with this circuit automated easily with electronic controls and computer interface. Printout provides status of each conductor in cable, indicating which, if any, of conductors has open or short circuit.

  11. Wire in the Cable-Driven System of Surgical Robot

    Science.gov (United States)

    Wang, X. F.; Lv, N.; Mu, H. Z.; Xue, L. J.

    2017-07-01

    During the evolution of the surgical robot, cable plays an important role. It translates motion and force precisely from surgeon’s hand to the tool’s tips. In the paper, the vertical wires, the composition of cable, are mathematically modeled from a geometric point of view. The cable structure and tension are analyzed according to the characteristics of wire screw twist. The structural equations of the wires in different positions are derived for both non-bent cable and bent cable, respectively. The bending moment formula of bent cable is also obtained. This will help researchers find suitable cable and design more matched pulley.

  12. What Is Data Cabling and Why It's Necessary for Businesses

    OpenAIRE

    IT Support

    2017-01-01

    What is Data Cabling? A structured cabling system is a type of network construction that is open and is used by different systems like data, access management, telephony, building automation, along with many other similar capabilities. It is an extremely flexible and economical set up. Usually, a cabling system such as this can be broken into six components: work space, horizontal cabling, backbone cabling, gear space, telecommunication closet (room) and entrance ways. Common Network ...

  13. MIMO Device Performance Testing with the Wireless Cable Method

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Hentilä, Lassi

    2018-01-01

    Conducted cable testing has been dominantly utilized in the industry to evaluate multiple-input multiple-output (MIMO) capable mobile terminals. Desired testing signals can be guided directly to the antenna ports on the mobile terminal by radio frequency (RF) coaxial cables in the conducted cable...... of the wireless cable method is done both in simulation and active throughput measurements. Future directions and applicability of the wireless cable method are also discussed....

  14. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges.

    Science.gov (United States)

    Sun, Bing-nan; Wang, Zhi-gang; Ko, J M; Ni, Y Q

    2003-01-01

    This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced.

  15. On the Minimum Cable Tensions for the Cable-Based Parallel Robots

    Directory of Open Access Journals (Sweden)

    Peng Liu

    2014-01-01

    Full Text Available This paper investigates the minimum cable tension distributions in the workspace for cable-based parallel robots to find out more information on the stability. First, the kinematic model of a cable-based parallel robot is derived based on the wrench matrix. Then, a noniterative polynomial-based optimization algorithm with the proper optimal objective function is presented based on the convex optimization theory, in which the minimum cable tension at any pose is determined. Additionally, three performance indices are proposed to show the distributions of the minimum cable tensions in a specified region of the workspace. An important thing is that the three performance indices can be used to evaluate the stability of the cable-based parallel robots. Furthermore, a new workspace, the Specified Minimum Cable Tension Workspace (SMCTW, is introduced, within which all the minimum tensions exceed a specified value, therefore meeting the specified stability requirement. Finally, a camera robot parallel driven by four cables for aerial panoramic photographing is selected to illustrate the distributions of the minimum cable tensions in the workspace and the relationship between the three performance indices and the stability.

  16. Ecology: Electrical Cable Bacteria Save Marine Life

    DEFF Research Database (Denmark)

    Nielsen, Lars Peter

    2016-01-01

    Animals at the bottom of the sea survive oxygen depletion surprisingly often, and a new study identifies cable bacteria in the sediment as the saviors. The bacterial electrical activity creates an iron 'carpet', trapping toxic hydrogen sulfide....

  17. Thermally induced EMF in unirradiated MI cables

    Science.gov (United States)

    Vila, R.; Hodgson, E. R.

    2007-08-01

    Radiation and temperature induced currents and voltages in mineral insulated (MI) cables, (generally termed RIEMF and TIEMF, respectively) have recently been the object of discussion and study. The problem is due to a possible electromagnetic force (EMF) generated along the centre conductor of ITER magnetic diagnostic coils in a radiation field, and the difficulty of separating radiation and temperature effects from the required signal. Previous work has shown the importance of temperature gradient effects. To address this problem further, studies of TIEMF have been carried out on an MI cable across the ends of the centre conductor at temperatures up to 550 °C, making point-by-point measurements, as well as annealing tests. It has been confirmed that voltage maxima appear in well-localized regions of the cable, indicating that some inhomogeneity is present. No geometric variations were observed by X-ray imaging of the cable.

  18. Bias in Cable News: Persuasion and Polarization

    OpenAIRE

    Martin, Gregory J; Ali Yurukoglu

    2014-01-01

    We measure the persuasive effects of slanted news and tastes for like-minded news, exploiting cable channel positions as exogenous shifters of cable news viewership. Channel positions do not correlate with demographics that predict viewership and voting, nor with local satellite viewership. We estimate that Fox News increases Republican vote shares by 0.3 points among viewers induced into watching 2.5 additional minutes per week by variation in position. We then estimate a model of voters who...

  19. Cable system transients theory, modeling and simulation

    CERN Document Server

    Ametani, Akihiro; Nagaoka, Naoto

    2015-01-01

    A systematic and comprehensive introduction to electromagnetic transient in cable systems, written by the internationally renowned pioneer in this field Presents a systematic and comprehensive introduction to electromagnetic transient in cable systems Written by the internationally renowned pioneer in the field Thorough coverage of the state of the art on the topic, presented in a well-organized, logical style, from fundamentals and practical applications A companion website is available

  20. A Cable-Shaped Lithium Sulfur Battery.

    Science.gov (United States)

    Fang, Xin; Weng, Wei; Ren, Jing; Peng, Huisheng

    2016-01-20

    A carbon nanostructured hybrid fiber is developed by integrating mesoporous carbon and graphene oxide into aligned carbon nanotubes. This hybrid fiber is used as a 1D cathode to fabricate a new cable-shaped lithium-sulfur battery. The fiber cathode exhibits a decent specific capacity and lifespan, which makes the cable-shaped lithium-sulfur battery rank far ahead of other fiber-shaped batteries. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Two-way cable television system characterization

    Science.gov (United States)

    Schauer, Paul T.

    1995-11-01

    This presentation is a report of the testing activities of the CableLabs Network Integrity Working Group. The working group consisted of several CableLabs member companies which conducted rf analog and digital bit-error testing at five CATV networks in the U.S. and Canada. The purpose of the working group was to measure the reliability and availability of the contemporary CATV network as specified by traditional switched access telephony performance parameters. Transmission data was collected for both forward and reverse (sub- split) paths of the rf broadband network, in both traditional and hybrid fiber/coax architectures, and for baseline and controlled variation events. The basic premise of this testing was to ascertain which cable television network elements adversely affected transmission of a 'generic' digital communications system and how they can be managed or controlled. The digital transmission utilized in the test was a QPSK modulated, T-1 rate (1.544 Mbit/second), modem without error correction. The intent was not to derive the necessary modulation technique and error correction scheme to properly operate in every cable television system, but rather to determine the principal sources of impairments existing in these networks and deduce corrective measures. The full report of the Network Integrity Working Group is published by CableLabs, Inc., and is titled, 'Two-Way Cable Television System Characterization -- Final Report', April 1995.

  2. Environmental assessment of submarine power cables

    Energy Technology Data Exchange (ETDEWEB)

    Isus, Daniel; Martinez, Juan D. [Grupo General Cable Sistemas, S.A., 08560-Manlleu, Barcelona (Spain); Arteche, Amaya; Del Rio, Carmen; Madina, Virginia [Tecnalia Research and Innovation, 20009 San Sebastian (Spain)

    2011-03-15

    Extensive analyses conducted by the European Community revealed that offshore wind energy have relatively benign effects on the marine environment by comparison to other forms of electric power generation [1]. However, the materials employed in offshore wind power farms suffer major changes to be confined to the marine environment at extreme conditions: saline medium, hydrostatic pressure... which can produce an important corrosion effect. This phenomenon can affect on the one hand, to the material from the structural viewpoint and on the other hand, to the marine environment. In this sense, to better understand the environmental impacts of generating electricity from offshore wind energy, this study evaluated the life cycle assessment for some new designs of submarine power cables developed by General Cable. To achieve this goal, three approaches have been carried out: leaching tests, eco-toxicity tests and Life Cycle Assessment (LCA) methodologies. All of them are aimed to obtaining quantitative data for environmental assessment of selected submarine cables. LCA is a method used to assess environmental aspects and potential impacts of a product or activity. LCA does not include financial and social factors, which means that the results of an LCA cannot exclusively form the basis for assessment of a product's sustainability. Leaching tests results allowed to conclude that pH of seawater did not significantly changed by the presence of submarine three-core cables. Although, it was slightly higher in case of broken cable, pH values were nearly equals. Concerning to the heavy metals which could migrate to the aquatic medium, there were significant differences in both scenarios. The leaching of zinc is the major environmental concern during undersea operation of undamaged cables whereas the fully sectioned three-core cable produced the migration of significant quantities of copper and iron apart from the zinc migrated from the galvanized steel. Thus, the tar

  3. Study of an YBCO HTS transmission cable system

    Energy Technology Data Exchange (ETDEWEB)

    Mukoyama, S. [Furukawa Electric Co., Ltd., Ecology and Energy Laboratory, 6, Yawata-Kaigandori, Ichihara, Chiba 290-8555 (Japan)], E-mail: mukoyama@ch.furukawa.co.jp; Yagi, M.; Hirano, N. [Furukawa Electric Co., Ltd., Ecology and Energy Laboratory, 6, Yawata-Kaigandori, Ichihara, Chiba 290-8555 (Japan); Amemiya, N. [Yokohama National University, Yokohama 240-8501 (Japan); Kashima, N.; Nagaya, S. [Chubu Electric Power Company, Nagoya 459-8522 (Japan); Izumi, T.; Shiohara, Y. [Superconductivity Research Laboratory, Tokyo 135-0062 (Japan)

    2007-10-01

    HTS transmission cables offer an innovative transmission line that differs from conventional technologies because HTS cables can send bulk power with extremely low loss. The HTS cable will contribute to energy saving and the prevention of global warming technologically. Reduction of cable loss is the most important development in economical cables for power networks. Today, second generation (2G) wires, such as an YBCO tape, are considered to have the potential to reduce AC loss. We developed YBCO power cables and succeeded in reducing AC loss to one-sixth the loss of BSCCO cable. According to our estimations, the total loss of an YBCO cable will be half the conventional (normal conducting) cable but yield the same power capacity.

  4. Application study on the first cable-stayed bridge with CFRP cables in China

    Directory of Open Access Journals (Sweden)

    Kuihua Mei

    2015-08-01

    Full Text Available In order to push forward the development of CFRP cable-stayed bridge and accumulate experiences, the study on the application of the first cable-stayed bridge with CFRP cables in China was carried out. The design essentials of main components of the bridge were introduced and its integral performances, including static properties, dynamic properties and seismic response were analyzed using finite element method. A new bond-type anchorage was developed and the processes of fabricating and installing CFRP cables were elaborated. Based on the results of construction simulation, a tension scheme for bridge was propound. During constructing, the stresses and displacement of girder and pylon, as well as the forces and stresses of cables, were tested. The results indicate that all sections of the bridge could meet the requirements of the ultimate bearing capacity and normal service; the performance of the anchorage is good and the stresses in each cable system are similar; the tested values accord well with the calculated values. Further, creep deformation of the resin in anchorages under service load is not obvious. All these results demonstrate that the first application of CFRP cables in the cable-stayed bridge in China is successful.

  5. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  6. Evaluation of cable ageing in Nuclear Power Plants; Evaluacion del envejecimiento de cables en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Vergara, T. [Empresarios Agrupados, A. I. E. Madrid (Spain); Alonso Chicote, J. [TECNATOM, S. A. (Spain); Burnay, S. [AEA Technology (UK)

    2000-07-01

    The majority of power, control and instrumentation cables in nuclear power plants use polymers as their basic material for insulation and jacket. In many cases, these cables form part of safety-related circuits and should therefore be capable of operating correctly under both normal and accident conditions. Since polymeric materials are degraded by the long term action of the radiation and thermal environments found in the plant, it is important to be able to establish the cable condition during the plant lifetime. Nowadays there are a number of different methods to evaluate the remaining lifetime of cables. In the case of new plants, or new cables in old plants, accelerated ageing tests and predictive models can be used to establish the behaviour of the cable materials under operating conditions. There are verified techniques and considerable experience in the definition of predictive models. This type of approach is best carried out during the commissioning stage or in the early stages of operation. In older plants, particularly where there is a wide range of cable types in use, it is more appropriate to use condition monitoring methods to establish the state of degradation of cables in-plant. Over the last 10 years there have been considerable developments in methods for condition monitoring of cables and a tool-box of practical techniques are now available. There is no single technique which is suitable for all cable materials but the range of methods covers nearly all of the types currently in use, at present, the most established methods are the indented, thermal analysis (OIT, OITP and TGA) and dielectric loss measurements, All of these are either non-destructive methods or require only micro-samples of material. (Author) 15 refs.

  7. Detonator cable initiation system safety investigation: Consequences of energizing the detonator and actuator cables

    Energy Technology Data Exchange (ETDEWEB)

    Osher, J.; Chau, H.; Von Holle, W.

    1994-03-01

    This study was performed to explore and assess the worst-case response of a W89-type weapons system, damaged so as to expose detonator and/or detonator safing strong link (DSSL) cables to the most extreme, credible lightning-discharge, environment. The test program used extremely high-current-level, fast-rise-time (1- to 2-{mu}s) discharges to simulate lightning strikes to either the exposed detonator or DSSL cables. Discharges with peak currents above 700 kA were required to explode test sections of detonator cable and launch a flyer fast enough potentially to detonate weapon high explosive (HE). Detonator-safing-strong-link (DSSL) cables were exploded in direct contact with hot LX-17 and Ultrafine TATB (UFTATB). At maximum charging voltage, the discharge system associated with the HE firing chamber exploded the cables at more than 600-kA peak current; however, neither LX-17 nor UFTATB detonated at 250{degree}C. Tests showed that intense surface arc discharges of more than 700 kA/cm in width across the surface of hot UFTATB [generally the more sensitive of the two insensitive high explosives (IHE)] could not initiate this hot IHE. As an extension to this study, we applied the same technique to test sections of the much-narrower but thicker-cover-layer W87 detonator cable. These tests were performed at the same initial stored electrical energy as that used for the W89 study. Because of the narrower cable conductor in the W87 cables, discharges greater than 550-kA peak current were sufficient to explode the cable and launch a fast flyer. In summary, we found that lightning strikes to exposed DSSL cables cannot directly detonate LX-17 or UFTATB even at high temperatures, and they pose no HE safety threat.

  8. High voltage pulsed cable design: a practical example

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Boicourt, G.P.

    1979-01-01

    The design of optimum high voltage pulse cable is difficult because very little emperical data are available on performance in pulsed applications. This paper follows the design and testing of one high voltage pulse cable, 40/100 trigger cable. The design was based on an unproven theory and the impressive outcome lends support to the theory. The theory is outlined and it is shown that there exists an inductance which gives a cable of minimum size for a given maximum stress. Test results on cable manufactured according to the design are presented and compared with the test results on the cable that 40/100 replaces.

  9. Energy losses of superconducting power transmission cables in the grid

    DEFF Research Database (Denmark)

    Østergaard, Jacob; Okholm, Jan; Lomholt, Karin

    2001-01-01

    One of the obvious motives for development of superconducting power transmission cables is reduction of transmission losses. Loss components in superconducting cables as well as in conventional cables have been examined. These losses are used for calculating the total energy losses of conventional...... as well as superconducting cables when they are placed in the electric power transmission network. It is concluded that high load connections are necessary to obtain energy saving by the use of HTSC cables. For selected high load connections, an energy saving of 40% is expected. It is shown...... that the thermal insulation and cooling machine efficiency are the most important loss element in a superconducting cable system...

  10. Stability Measurements of Rutherford Cables with Various Treatments

    CERN Document Server

    Kim, S W; Wilson, M N; Ghosh, A; Sampson, W B

    1999-01-01

    To improve the stability of Rutherford type superconducting cables, various methods of treating cables were considered and tested. These treatments include strand coating, partial soldering, "barber-pole" insulation and "porous $9 metal" solder filling. To study the effect of these treatments, several cables were prepared and MQE (minimum quench energy) values were measured. Coating, partial soldering or "barber-pole insulation" improved the relative stability $9 for some cables. The "porous metal" filled cables showed higher MQE. However the results suggest that the porous metal process needs to be improved. The measured data for cables with various treatments are presented. (8 refs).

  11. Development of innovative superconducting DC power cable

    Energy Technology Data Exchange (ETDEWEB)

    Matsushita, Teruo; Kiuchi, Masaru [Dept. of Computer Science and Electronics Kyushu Institute of Technology, Iizuka (Japan)

    2017-09-15

    It is required to reduce the cost of superconducting cable to realize a superconducting DC power network that covers a wide area in order to utilize renewable energy. In this paper a new concept of innovative cable is introduced that can enhance the current-carrying capacity even though the same superconducting tape is used. Such a cable can be realized by designing an optimal winding structure in such a way that the angle between the tape and magnetic field becomes small. This idea was confirmed by preliminary experiments for a single layer model cable made of Bi-2223 tapes and REBCO coated conductors. Experiments of three and four layer cables of practical sizes were also done and it was found that the current-carrying capacity increased as theoretically predicted. If the critical current properties of commercial superconducting tapes are further improved in a parallel magnetic field, the enhancement will become pronounced and this technology will surely contribute to realization of superconducting DC power network.

  12. Coaxial cable distribution plant performance simulation

    Science.gov (United States)

    Carangi, Mark D.; Chen, Walter Y.; Kerpez, Kenneth J.; Valenti, Craig F.

    1995-11-01

    The CATV system delivers analog video signals from a centralized headend through a tree- and-branch fiber/coax network. That architecture is very cost effective for delivering broadcast video channels to a vast area. The introduction of interactive TV, data and telephony services requires an upstream link from customers to the headend. Although equipment for upstream transmission is available, CATV systems are primarily engineered for the delivery of one way analog broadcast TV programs. In this paper, issues related to two-way digital transmission through the coaxial cable distribution plant are examined. The objective is to establish a reliable computer modeling environment for the study and simulation of general and advanced transmission systems over the coaxial cable distribution plant. The discussions are focused on three general topics: the coaxial cable distribution plant transmission channel, the corresponding noise environment, and applicable transmission system architectures. Two- port network models are developed for the components (coaxial cable, taps, etc.) of the coaxial cable distribution plant. A realistic distribution plant channel model can be constructed based on these component models. The distribution plant noise level is analyzed based on thermal noise level, amplifier noise figure, and the funneling effect. The upstream ingress noise model is also developed. Three advanced transmission systems, adaptive transmitter, frame based equalization, and discrete multitone (DMT), are presented. End to end computer simulation results are presented using QPSK upstream.

  13. The glass story: fibre optic cable

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2000-12-01

    Fibre optic cable has become the glamour pinup among cables as a result of its ability to carry billions of digital bits of information per second. Fibre optic cables consist of hair-thin fibres of high purity silica glass; enclosed in its protective shield and glass cladding, the cable is immune to electromagnetic interference and carries out its task without the need for boosting. It is the perfect answer to the ever-increasing need for speed and capacity of today's high-speed computers. This paper describes the nature of fibre optics, the two major optical fibre categories of multi-mode and single-mode, and the various possible applications for each type. Although the optical performance of fibres is relatively standardized regardless of the manufacturer, physical characteristics do vary across the industry. Fibre type and fibre parameters are usually defined by the transmission system application, whereas the cable design is usually determined by the physical environment of the particular installation. 1 tab., 5 figs.

  14. Electrothermal Coordination in Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Gudmundsdottir, Unnur Stella

    2013-01-01

    behavior of the components. The dynamic temperature calculations of power cables are suggested to be based on thermoelectric equivalents (TEEs). It is shown that the thermal behavior can be built into widely used load flow software, creating a strong ETC tool. ETC is, through two case scenarios, proven......Electrothermal coordination (ETC) is introduced for cable based transmission grids. ETC is the term covering operation and planning of transmission systems based on temperature, instead of current. ETC consists of one part covering the load conditions of the system and one covering the thermal...... to be beneficial for both operator and system planner. It is shown how the thermal behavior can be monitored in real-time during normal dynamic load and during emergencies. In that way, ETC enables cables to be loaded above their normal rating, while maintaining high reliability of the system, which potentially...

  15. Computer-Aided Engineering Of Cabling

    Science.gov (United States)

    Billitti, Joseph W.

    1989-01-01

    Program generates data sheets, drawings, and other information on electrical connections. DFACS program, centered around single data base, has built-in menus providing easy input of, and access to, data for all personnel involved in system, subsystem, and cabling. Enables parallel design of circuit-data sheets and drawings of harnesses. Also recombines raw information to generate automatically various project documents and drawings, including index of circuit-data sheets, list of electrical-interface circuits, lists of assemblies and equipment, cabling trees, and drawings of cabling electrical interfaces and harnesses. Purpose of program to provide engineering community with centralized data base for putting in, and gaining access to, functional definition of system as specified in terms of details of pin connections of end circuits of subsystems and instruments and data on harnessing. Primary objective to provide instantaneous single point of interchange of information, thus avoiding

  16. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  17. Distance and Cable Length Measurement System

    Directory of Open Access Journals (Sweden)

    Jonay Toledo

    2009-12-01

    Full Text Available A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement.

  18. Analysis of Electrical Coupling Parameters in Superconducting Cables

    CERN Document Server

    Bottura, L; Rosso, C

    2003-01-01

    The analysis of current distribution and redistribution in superconducting cables requires the knowledge of the electric coupling among strands, and in particular the interstrand resistance and inductance values. In practice both parameters can have wide variations in cables commonly used such as Rutherford cables for accelerators or Cable-in-Conduits for fusion and SMES magnets. In this paper we describe a model of a multi-stage twisted cable with arbitrary geometry that can be used to study the range of interstrand resistances and inductances that is associated with variations of geometry. These variations can be due to cabling or compaction effects. To describe the variations from the nominal geometry we have adopted a cable model that resembles to the physical process of cabling and compaction. The inductance calculation part of the model is validated by comparison to semi-analytical results, showing excellent accuracy and execution speed.

  19. Energy analysis of vehicle-to-cable barrier impacts.

    Science.gov (United States)

    2013-06-01

    An accident reconstruction technique was developed for estimating the energy absorbed during an impact with a cable barrier system as well as the initial impact velocity. The kinetic energy absorbed during a cable barrier system impact is comprised o...

  20. Superconducting power cables in Denmark - a case study

    DEFF Research Database (Denmark)

    Østergaard, Jacob

    1997-01-01

    that HTS cables will be less expensive for high power ratings, have lower losses for lines with a high load, and have a reduced reactive power production. The use of superconducting cables in Denmark accommodate plans by the Danish utility to make a substantial conversion of overhead lines to underground......A case study of a 450 MVA, 132 kV high temperature superconducting (HTS) power transmission cable has been carried out. In the study, a superconducting cable system is compared to a conventional cable system which is under construction for an actual transmission line in the Danish grid. The study...... considers the design and development of a calculation model for an HTS cable system including auxiliary facilities. From calculations of the selected transmission line, conclusions on the feasibility of HTS cables in Denmark are made. HTS cables appear to be feasible in Denmark. Calculations indicate...

  1. Modeling of the power cable production line

    Energy Technology Data Exchange (ETDEWEB)

    Kosar, Vanja; Gomzi, Zoran [Faculty of Chemical Engineering and Technology, Department of Reaction Engineering and Catalysis, University of Zagreb, Savska c. 16, HR-10000 Zagreb (Croatia)

    2007-06-15

    During the manufacturing of a power cable insulated with the cross-linkable polyethylene, the hot polymer is applied to the conductor by extrusion, below temperatures of the rapid cross-linking. The coated cable passes into a high-pressure tube (filled with nitrogen under the pressure of 10 bar) in order to heat up the insulation to temperatures at which the cross-linking agent is highly active. This is the continuous vulcanization (CV) tube. Changes of process variables associated with the CV tube can cause changes in the physical properties, the aging characteristics, and especially the heat resistance of the cable insulation. Performance of insulating compounds in this area of the cross-linking process can determine maximum output rates of a power cable manufacturing facility. The mathematical model describes cross-linking process in the vulcanization tube, which is in fact a tubular reactor. In the vulcanization tube heat is transferred by convection, conduction and radiation. Also, the reaction heat is liberated by the chemical reaction and the heat balance describes all four impacts. Formal part of the mathematical model is a material balance that describes the reactions kinetics. Heat and mole balance are connected with reaction rate and mathematically present a system of partial differential equations which will be numerically solved for chosen boundary conditions, both for the reaction part and for the cooling part of a process. On the basis of the real process parameters and the presented mathematical model simulation of the process was conducted. From the presented simulation the optimal process parameters such as process temperatures, cable linear velocity (u) and cable cooling properties of CV line are predicted and evaluated. (author)

  2. Ecuador: David y Goliat en el cable

    Directory of Open Access Journals (Sweden)

    Blasco Fernando Checa Montúfar

    2015-01-01

    Full Text Available Hay un enorme desequilibrio en la televisión ecuatoriana pagada, por un lado la existencia solo de dos operadores de cable, uno de los cuales capta el 90 por ciento del mercado actual y por otro, la histórica supremacía de Estados Unidos en la pantalla electrónica latinoamericana es más dramática en el cable ecuatoriano: en algún caso, el 80 por ciento de canales ofertados provienen de ese país. Es necesaria una "honda" sostenida, compartida y plural para derribar esta supremacía.

  3. Calorimetric measurements of losses in HTS cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Veje, Niels Erling Winsløv; Rasmussen, Carsten

    2001-01-01

    A calorimetric test rig is used to investigate various loss components in a 10 m long superconducting cable model. A calorimetric technique, based on thermocouple measurements, is used to measure the losses of the 10 m long superconducting cable model. The current dependent losses are also measured...... electrically and compared with the losses obtained with the calorimetric method. The results obtained by the two methods are consistent. Based on an I2 (current) fitting procedure, the loss, caused by the eddy current generated in the stainless steel cryostat housing, and the hysteresis loss generated...

  4. Flat conductor cable for electrical packaging

    Science.gov (United States)

    Angele, W.

    1972-01-01

    Flat conductor cable (FCC) is relatively new, highly promising means for electrical packaging and system integration. FCC offers numerous desirable traits (weight, volume and cost savings, flexibility, high reliability, predictable and repeatable electrical characteristics) which make it extremely attractive as a packaging medium. FCC, today, finds wide application in everything from integration of lunar equipment to the packaging of electronics in nuclear submarines. Described are cable construction and means of termination, applicable specifications and standards, and total FCC systems. A list of additional sources of data is also included for more intensive study.

  5. Power applications for superconducting cables in Denmark

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob; Olsen, S. Krüger

    1999-01-01

    In Denmark a growing concern for environmental protection has lead to wishes that the open country is kept free of overhead lines as far as possible. New lines under 100 kV and existing 60/50 kV lines should be established as underground cables. Superconducting cables represent an interesting...... can be combined with other new technologies such as HVDC light transmission using isolated gate bipolar transistors (IGBTs). The network needed in a system with a substantial wind power generation has to be very strong in order to handle energy fluctuations. Such a network will be possible...

  6. Influence of Icing on Bridge Cable Aerodynamics

    DEFF Research Database (Denmark)

    Koss, Holger; Frej Henningsen, Jesper; Olsen, Idar

    2013-01-01

    °C may lead to large amplitude vibrations of bridge cables under wind action. For the prediction of aerodynamic instability quasi-steady models have been developed estimating the cable response magnitude based on structural properties and aerodynamic force coefficients for drag, lift and torsion....... The determination of these force coefficients require a proper simulation of the ice layer occurring under the specific climatic conditions, favouring real ice accretion over simplified artificial reproduction. The work presented in this paper was performed to study the influence of ice accretion on the aerodynamic...

  7. The Protection of Undersea Cables: A Global Security Threat

    Science.gov (United States)

    2012-03-07

    10 Samuel Morse demonstrated “ Morse Code” in 1844 and patented the design in 1850. The first undersea ( telegraph ) cable was laid between England... telegraph cable linked London with the new world, via Newfoundland.2 The 143 words transmitted in 10 hours, replaced a one-way dispatch that would...Cable History The history of undersea cables started in 1795 when a Spaniard named Salva suggested the idea of underwater telegraphic communication

  8. 24 CFR 3285.906 - Telephone and cable TV.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Telephone and cable TV. 3285.906... Installation Instructions § 3285.906 Telephone and cable TV. It is recommended that the installation instructions explain that telephone and cable TV wiring should be installed in accordance with requirements of...

  9. 24 CFR 3285.704 - Telephone and cable TV.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Telephone and cable TV. 3285.704....704 Telephone and cable TV. Refer to § 3285.906 for considerations pertinent to installation of telephone and cable TV. ...

  10. Results from the Danish high temperature superconducting power cable project

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob

    2002-01-01

    For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying...

  11. Perturbation of near-field scan from connected cables

    DEFF Research Database (Denmark)

    Sørensen, Morten; Franek, Ondrej; Pedersen, Gert Frølund

    2012-01-01

    The perturbation of near-fields scan from connected cables are investigated and how to handle the cables is discussed. A connected cable induced small but theoretical detectable changes in the near-field. This change can be seen in Huygens’ box simulations (equivalent source currents on a box) at...

  12. Cable Television 1980: Status and Prospect for Higher Education.

    Science.gov (United States)

    Baus, F., Ed.

    Baseline information for the would-be cable television educational programer is provided by two papers, one an overview of the state of the cable television industry, and the other a report on a marketing study conducted to determine consumer attitudes toward cable TV as an educational medium. In "The Promise and Reality of Cable…

  13. North Sea submarine cable disruptions and fishing activity

    NARCIS (Netherlands)

    Hintzen, N.T.; Machiels, M.A.M.

    2014-01-01

    At the North Sea seafloor, numerous submarine cables are positioned that connect telecommunication networks between countries. Worldwide, human activities cause most of the cable disruptions with fisheries accounting for nearly half of all reported faults. Due to a recent increase of submarine cable

  14. Numerical solutions of the current distribution in superconducting cables

    NARCIS (Netherlands)

    Hartmann, R.A.; Rem, P.C.; van de Klundert, L.J.M.

    1987-01-01

    Superconducting cables are described by current sheets using the continuum model of W. Carr Jr. [1] and assuming an anisotropic conductivity. Two different situations are considered: a) finite length of cable in spatially independent magnetic field; b) infinitely long cable in a periodical magnetic

  15. FCC Commissioner, Legal Assistant and Staff Perceptions of Cable TV.

    Science.gov (United States)

    Krugman, Dean M.

    1979-01-01

    Describes a methodology used in interviewing Federal Communications Commission commissioners, legal assistants, and Cable Bureau staff members about their attitudes toward the cable industry and regulation; reports results of the interviews, noting respondents' disappointment in the lack of cable growth. (GT)

  16. Understanding losses in three core armoured submarine cables

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Ebdrup, Thomas; Bak, Claus Leth

    2016-01-01

    As the number of offshore wind farms increases so does the number of array cables. The array cables are used to interconnect the wind turbines in a wind farm and to connect the wind farm to a collector platform, whereas the connection to shore is performed by means of a HV transmission cable. For...

  17. 47 CFR 76.111 - Cable sports blackout.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  18. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  19. 46 CFR 111.60-6 - Fiber optic cable.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fiber optic cable. 111.60-6 Section 111.60-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-6 Fiber optic cable. Each fiber optic cable must— (a) Be...

  20. 30 CFR 75.600-1 - Approved cables; flame resistance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved cables; flame resistance. 75.600-1 Section 75.600-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... cables; flame resistance. Cables shall be accepted or approved by MSHA as flame resistant. ...

  1. 30 CFR 75.600 - Trailing cables; flame resistance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; flame resistance. 75.600 Section 75.600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... cables; flame resistance. Trailing cables used in coal mines shall meet the requirements established by...

  2. Broadband Wireline Provider Service: Cable Modem - Other; BBRI_cableOther12

    Data.gov (United States)

    University of Rhode Island Geospatial Extension Program — This dataset represents the availability of wireline broadband Internet access in Rhode Island via "Cable Modem - Other" technology. Broadband availability is...

  3. Broadband Wireline Provider Service: Cable Modem - DOCSIS 3.0; BBRI_cableDOCSIS12

    Data.gov (United States)

    University of Rhode Island Geospatial Extension Program — This dataset represents the availability of wireline broadband Internet access in Rhode Island via "Cable Modem - DOCSIS 3.0" technology. Broadband availability is...

  4. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  5. Microminiature coaxial cable and method of manufacture

    Science.gov (United States)

    Bongianni, Wayne L.

    1989-01-01

    A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

  6. Microminiature coaxial cable and methods of manufacture

    Science.gov (United States)

    Bongianni, W.L.

    1983-12-29

    A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 ..mu..m thick and from 150 to 200 ..mu..m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dieleectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

  7. Microminiature coaxial cable and methods manufacture

    Science.gov (United States)

    Bongianni, Wayne L.

    1986-01-01

    A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

  8. Microminiature coaxial cable and method of manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Bongianni, W.L.

    1989-03-28

    A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

  9. Microminiature coaxial cable and methods manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Bongianni, W.L.

    1986-04-08

    A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

  10. 14 CFR 25.689 - Cable systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cable systems. 25.689 Section 25.689 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... smaller than 1/8 inch in diameter may be used in the aileron, elevator, or rudder systems; and (2) Each...

  11. History of cable-stayed bridges

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    1999-01-01

    The principle of supporting a bridge deck by inclined tension members leading to towers on either side of the span has been known for centuries. However, the real development of cable-stayed bridges did not begin before the 1950s. Since then the free span has been increased from 183 m in the Strö...

  12. Space charge fields in DC cables

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C; Pedersen, Aage

    1996-01-01

    The space charge that accumulates in DC cables can, mathematically, be resolved into two components. One is related to the temperature and the other to the magnitude of the electric field strength. Analytical expressions for the electric fields arising from each of these space charge components...

  13. Submarine Telecommunication Cables in Disputed Maritime Areas

    NARCIS (Netherlands)

    van Logchem, Youri

    2014-01-01

    There are a considerable number of maritime areas where no boundary exists, or where a boundary is delimited only in part. This article deals with the issue of submarine telecommunication cables, which are sometimes placed on the seabed or buried in the subsoil of areas that are claimed by multiple

  14. Cinema Futures: Cain, Abel or Cable?

    NARCIS (Netherlands)

    Elsaesser, Thomas; Hoffmann, Kay

    1998-01-01

    In the late 1960s, the cinema was pronounced dead. Television, like a Biblical Cain had slain his brother Abel. Some thirty years later, a remarkable reversal: rarely has the cinema been more popular. And yet, rarely has the cinema's future seemed more uncertain. Cinema Futures: Cain, Abel or Cable?

  15. Power laws from linear neuronal cable theory

    DEFF Research Database (Denmark)

    Pettersen, Klas H; Lindén, Henrik Anders; Tetzlaff, Tom

    2014-01-01

    suggested to be at the root of this phenomenon, we here demonstrate a possible origin of such power laws in the biophysical properties of single neurons described by the standard cable equation. Taking advantage of the analytical tractability of the so called ball and stick neuron model, we derive general...

  16. Study on Impedance Characteristics of Aircraft Cables

    Directory of Open Access Journals (Sweden)

    Weilin Li

    2016-01-01

    Full Text Available Voltage decrease and power loss in distribution lines of aircraft electric power system are harmful to the normal operation of electrical equipment and may even threaten the safety of aircraft. This study investigates how the gap distance (the distance between aircraft cables and aircraft skin and voltage frequency (variable frequency power supply will be adopted for next generation aircraft will affect the impedance of aircraft cables. To be more precise, the forming mechanism of cable resistance and inductance is illustrated in detail and their changing trends with frequency and gap distance are analyzed with the help of electromagnetic theoretical analysis. An aircraft cable simulation model is built with Maxwell 2D and the simulation results are consistent with the conclusions drawn from the theoretical analysis. The changing trends of the four core parameters of interest are analyzed: resistance, inductance, reactance, and impedance. The research results can be used as reference for the applications in Variable Speed Variable Frequency (VSVF aircraft electric power system.

  17. Galloping instability to chaos of cables

    CERN Document Server

    Luo, Albert C J

    2017-01-01

    This book provides students and researchers with a systematic solution for fluid-induced structural vibrations, galloping instability and the chaos of cables. They will also gain a better understanding of stable and unstable periodic motions and chaos in fluid-induced structural vibrations. Further, the results presented here will help engineers effectively design and analyze fluid-induced vibrations.

  18. Observation of polyphosphate granules in cable bacteria

    Science.gov (United States)

    Yang, T.; Nielsen, L. P.; Risgaard-Petersen, N.

    2015-12-01

    Cable bacteria are long filamentous bacteria that capable for long distance electron transport: transporting electrons derived from oxidizing sulfide in anoxic layers, to oxygen at the sediment surface, over a distance of centimeters. Cable bacteria are found in many types of freshwater and marine sediment all over the world, with density of approximately thousands of kilometers per square meter. These long filaments are composed by individual cells closely related to Desulfobulbaceae, connected with a shared outer membrane inside which the strings structure are presumed to be highly conductive. The observed doubling time of cells within the filament is about 20 min, which is among the shortest compare to other bacteria. In these cable cells, we constantly observed polyphosphate granules (poly-P), regardless of cell dimension and shape. This is very interesting since it has long been recognized that the microbial polyP content is low during rapid growth and increases under unfavorable conditions, for example, increasing sulfide concentration and anoxia resulted in a decomposition of poly-P in Beggiatoa. Here, we investigated marine cable bacteria from Netherland and Aarhus Bay, focusing on the poly-P dynamics under various redox conditions. In poly-P stained cells, typically there are two big poly-P granules locate at each polar. In dividing cells, however, the morphology of poly-P changed to six small granules precisely arranged to two row. Moreover, the cells seem be able to continuously divide more than one time without elongation step. These varied poly-P morphologies demonstrate that poly-P is closely related to the cell growth and cell division, by an unknown mechanism. Individual cable filaments were picked up and were exposed to different redox conditions; our primary data indicated the cable cells could suffer anoxic condition better than oxic condition. We also detected decomposition of poly-P under anoxia. These results call for an in-depth examination

  19. Proposal for using commercial submarine telecommunications cables for monitoring earthquakes and tsunamis - the SMART cable concept

    Science.gov (United States)

    Tilmann, Frederik; Howe, Bruce; Butler, Rhett; Strollo, Angelo; Weinstein, Stuart

    2017-04-01

    Hundreds of thousands of kilometres of commercial telecommunications cables traverse the world's oceans, many of them crossing large ocean basins, which are otherwise poorly sampled by geophysical sensors (seismometers or pressure gauges), or running along active continental margins, where additional observations would be particularly valuable for allowing observation of subduction zone earthquakes and offshore plate deformation from the updip end. However, as of today these cables are unaware of their environment. These cables are equipped with repeaters spaced at 50 km intervals to boost the telecom signal, though. These repeaters in principle offer access to power and bandwidth, providing the opportunity to add sensor capability to future "SMART" cables (Science Monitoring and Reliable Telecommunications). In a workshop held in early November 2016 at the German Research Centre for Geosciences in Potsdam (GFZ) research scientists, practitioners from earthquake observatories and tsunami warning centers, and engineers discussed possible applications of such SMART cables both from the viewpoint of fundamental research, i.e. Earth imaging and the study of earthquake processes and possibly plate deformation, as well as technical aspects of possible implementations by drawing on the expertise of operators of existing cabled networks. In this presentation, we will summarise the outcomes of this workshop.

  20. Shape accuracy optimization for cable-rib tension deployable antenna structure with tensioned cables

    Science.gov (United States)

    Liu, Ruiwei; Guo, Hongwei; Liu, Rongqiang; Wang, Hongxiang; Tang, Dewei; Song, Xiaoke

    2017-11-01

    Shape accuracy is of substantial importance in deployable structures as the demand for large-scale deployable structures in various fields, especially in aerospace engineering, increases. The main purpose of this paper is to present a shape accuracy optimization method to find the optimal pretensions for the desired shape of cable-rib tension deployable antenna structure with tensioned cables. First, an analysis model of the deployable structure is established by using finite element method. In this model, geometrical nonlinearity is considered for the cable element and beam element. Flexible deformations of the deployable structure under the action of cable network and tensioned cables are subsequently analyzed separately. Moreover, the influence of pretension of tensioned cables on natural frequencies is studied. Based on the results, a genetic algorithm is used to find a set of reasonable pretension and thus minimize structural deformation under the first natural frequency constraint. Finally, numerical simulations are presented to analyze the deployable structure under two kinds of constraints. Results show that the shape accuracy and natural frequencies of deployable structure can be effectively improved by pretension optimization.

  1. Sixty-four-Channel Inline Cable Tester

    Science.gov (United States)

    2008-01-01

    Faults in wiring are a serious concern for the aerospace and aeronautics (commercial, military, and civil) industries. A number of accidents have occurred because faulty wiring created shorts or opens that resulted in the loss of control of the aircraft or because arcing led to fires and explosions. Some of these accidents have resulted in the massive loss of lives (such as in the TWA Flight 800 accident). Circuits on the Space Shuttle have also failed because of faulty insulation on wiring. STS-93 lost power when a primary power circuit in one engine failed and a second engine had a backup power circuit fault. Cables are usually tested on the ground after the crew reports a fault encountered during flight. Often such failures result from vibration and cannot be replicated while the aircraft is stationary. It is therefore important to monitor faults while the aircraft is in operation, when cables are more likely to fail. Work is in progress to develop a cable fault tester capable of monitoring up to 64 individual wires simultaneously. Faults can be monitored either inline or offline. In the inline mode of operation, the monitoring is performed without disturbing the normal operation of the wires under test. That is, the operations are performed unintrusively and are essentially undetectable for the test signal levels are below the noise floor. A cable can be monitored several times per second in the offline mode and once a second in the inline mode. The 64-channel inline cable tester not only detects the occurrence of a fault, but also determines the type of fault (short/open) and the location of the fault. This will enable the detection of intermittent faults that can be repaired before they become serious problems.

  2. Simulation of power cable ohm heat by using labview

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Y. H.; Kim, J. S.; Jung, I. S. [Korea Electric Power Research Institue, Taejon (Korea, Republic of)

    2003-07-01

    Even it is necessary to consider the ohm heat of cable conductor for the evaluation of cable aging, temperature measurement of cable conductor for the evaluation of cable aging, temperature measurement of cable conductor is impractical due to untouchable condition of cable conductor which is surrounded by insulation and jacket. We have studied the way how to get the ohm heat of conductor by measuring the surface temperature of cable jacket. We verified that jacket temperature can be controlled under the 10% error limit by applying the PI control in LabView program. The relation between surface temperature of jacket and ohm heat of conductor can be predicted after this type of experiment. This study show that the ohm heat can be delivered from temperature monitoring of jacket surface.

  3. submitter On Roebel Cable Geometry for Accelerator Magnet

    CERN Document Server

    Fleiter, J; Ballarino, A

    2016-01-01

    Roebel-type cables made of a ReBCO conductor are potential candidates for high-field accelerator magnets. The necessity to promote a large effective transverse section in a Roebel cable to avoid local overstress leading to degradation in electrical performance has been recently addressed. In this paper, a new geometry of meander tapes for a Roebel cable that enhances both the transverse effective section and the current margin at crossing segments is discussed. As Roebel cables are bent at the coil ends, the modulation of the bending radius of strands along the cable pitch leads to a shift of the strands with respect to each other. The shift magnitude is analytically investigated in this paper as a function of both cable features and coil geometry. Finally, the minimum transposition pitch of Roebel cables is determined on the basis of coil characteristics.

  4. Development of an underwater ROV system for submarine cable maintenance. Kaitei cable maintenance yo suichu robot no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iyama, T.; Takahashi, Y.; Kaya, F.; Shigemitsu, T. (Ishikawajima-Harima Heavy Industries, Co. Ltd., Tokyo (Japan))

    1992-07-01

    For the purpose of repairing, burying, and inspecting submarine telecommunication cables more speedily and at greater depth than conventional processes, an underwater remotely operated robot system for submarine cable maintenance has been developed. The system is composed of an underwater remotely operated vehicle (ROV), tether cables, a tether management system, umbilical cables, a launch and recovery system, control units, and electric power units. The ROV is loaded with thrusters for propulsion, a television camera, a cable location system, manipulators, a cable gripper/cutter unit, a cable burier/digger unit, a variable ballast unit, various sensors, et al. Since its entrance into service in October, 1989, the system has been successfully operated in various sea areas around Japan with a crew of three or four for operation and maintenance. This paper describes the outline of the system configuration and their specifications. 12 figs., 1 tab.

  5. Automated wireless monitoring system for cable tension using smart sensors

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jongwoong; Cho, Soojin; Spencer, Billie F.; Yun, Chung-Bang

    2013-04-01

    Cables are critical load carrying members of cable-stayed bridges; monitoring tension forces of the cables provides valuable information for SHM of the cable-stayed bridges. Monitoring systems for the cable tension can be efficiently realized using wireless smart sensors in conjunction with vibration-based cable tension estimation approaches. This study develops an automated cable tension monitoring system using MEMSIC's Imote2 smart sensors. An embedded data processing strategy is implemented on the Imote2-based wireless sensor network to calculate cable tensions using a vibration-based method, significantly reducing the wireless data transmission and associated power consumption. The autonomous operation of the monitoring system is achieved by AutoMonitor, a high-level coordinator application provided by the Illinois SHM Project Services Toolsuite. The monitoring system also features power harvesting enabled by solar panels attached to each sensor node and AutoMonitor for charging control. The proposed wireless system has been deployed on the Jindo Bridge, a cable-stayed bridge located in South Korea. Tension forces are autonomously monitored for 12 cables in the east, land side of the bridge, proving the validity and potential of the presented tension monitoring system for real-world applications.

  6. Offshore wind farm electrical cable layout optimization

    Science.gov (United States)

    Pillai, A. C.; Chick, J.; Johanning, L.; Khorasanchi, M.; de Laleu, V.

    2015-12-01

    This article explores an automated approach for the efficient placement of substations and the design of an inter-array electrical collection network for an offshore wind farm through the minimization of the cost. To accomplish this, the problem is represented as a number of sub-problems that are solved in series using a combination of heuristic algorithms. The overall problem is first solved by clustering the turbines to generate valid substation positions. From this, a navigational mesh pathfinding algorithm based on Delaunay triangulation is applied to identify valid cable paths, which are then used in a mixed-integer linear programming problem to solve for a constrained capacitated minimum spanning tree considering all realistic constraints. The final tree that is produced represents the solution to the inter-array cable problem. This method is applied to a planned wind farm to illustrate the suitability of the approach and the resulting layout that is generated.

  7. Water-tree resistant cable formulations

    Energy Technology Data Exchange (ETDEWEB)

    Sarma, H.; Dobbin, C.J.B.

    1992-10-06

    Polyethylene compositions are disclosed which are suitable for use as cable insulation for high voltage power distribution cables and, more particularly, contain an additive to inhibit the propagation of water trees in the insulation. The polyethylene composition of the invention is obtained by cross-linking a composition comprising ca 95 wt % of a low-density crosslinkable polyethylene and at least 1 wt % of a hydrolyzed terpolymer of ethylene, vinyl acetate, and vinyl alcohol. The terpolymer is obtained from the at least 95% hydrolysis of an ethylene-vinyl acetate copolymer having a 20-30 wt % vinyl acetate content. The polyethylene and the terpolymer have a substantially similar melt index. Tests conducted to evaluate insulation compositions of the invention are described. 1 fig., 4 tabs.

  8. Development of polymer packaging for power cable

    Directory of Open Access Journals (Sweden)

    S. Sremac

    2014-10-01

    Full Text Available This paper discusses the issues of product design and the procedure of developing polymer packaging as one of the most important engineering tasks. For the purpose of packing power cables a polymer packaging has been designed in the form of drum. Packaging and many other consumer products are largely produced using polymeric materials due to many positive features. High Density Polyethylene is the type of polyethylene proposed for packaging purposes due to its low degree of branching and strong intermolecular forces. Transport and storage processes were automated based on the radio-frequency identification technology. The proposed system is flexible in terms of its possibility of accepting and processing different types of cables and other products.

  9. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  10. Occupational Asthma in a Cable Manufacturing Company

    Science.gov (United States)

    Attarchi, Mirsaeed; Dehghan, Faezeh; Yazdanparast, Taraneh; Mohammadi, Saber; Golchin, Mahdie; Sadeghi, Zargham; Moafi, Masoud; Seyed Mehdi, Seyed Mohammad

    2014-01-01

    Background: During the past decade, incidence of asthma has increased, which might have been due to environmental exposures. Objectives: Considering the expansion of cable manufacturing industry in Iran, the present study was conducted to evaluate the prevalence of occupational asthma in a cable manufacturing company in Iran as well as its related factors. Patients and Methods: This study was conducted on employees of a cable manufacturing company in Yazd, Iran, in 2012. The workers were divided into two groups of exposure (to toluene diisocyanate, polyvinyl chloride, polyethylene or polypropylene) and without exposure. Diagnosis of occupational asthma was made based on the subjects’ medical history, spirometry and peak flowmetry, and its frequency was compared between the two groups. Results: The overall prevalence of occupational asthma was 9.7%. This rate was 13.8% in the exposed group. Logistic regression analysis showed that even after adjustment for confounding factors, a significant correlation existed between the frequency of occupational asthma and exposure to the produced dust particles (P < 0.05). In addition, age, work experience, body mass index, cigarette smoking and shift work had significant correlations with the prevalence of occupational asthma (P < 0.05). Conclusions: Considering the high prevalence of occupational asthma among cable manufacturing company workers in Iran, this issue needs to be addressed immediately in addition to reduction of exposure among subjects. Reduction in work shift duration, implementation of tobacco control and cessation programs for the personnel, and performing spirometry tests and respiratory examinations in shorter periods may be among effective measures for reducing the incidence of occupational asthma in this industry. PMID:25558389

  11. Examining cable plant bandwidth for FDDI

    Science.gov (United States)

    Hayes, James E.

    1991-02-01

    Networks designed around the ANSI X3T9. 5 standard called Fiber Distributed Data Interface (FDDI) are limited in distance by the bandwidth not the attenuation of the fiber optic cable. The magnitude of this limitation is defined and potential options in sources and fibers are examined. Since FDDI is limited in distance by the bandwidth of the cable plant not the attenuation many end users have put a bandwidth specification in their fiber optic cable purchase specifications. Some have even specified testing for bandwidth. This has caused much controversy between vendors installers and users. As a test equipment vendor we have " refereed" quite a few of these already and we have found that more myths are believed than realities are understood. What Limits Fiber Bandwidth? Two things limit fiber bandwidth: modal dispersion and chromatic dispersion. Modal dispersion is caused by the fact that the graded index profile of the fiber isn''t perfect so all modes do not have exactly the same transit time through the fiber. Chromatic dispersion is caused by the fact that the velocity of light in the fiber is dependent on the wavelength of the fiber. Fibers are designed for a zero dispersion wavelength light of any other wavelength will have some dispersion. Sources of wide spectral width like LEDs will suffer from more dispersion than narrow spectral width sources like laser diodes. In most circumstances one can

  12. Occupational asthma in a cable manufacturing company.

    Science.gov (United States)

    Attarchi, Mirsaeed; Dehghan, Faezeh; Yazdanparast, Taraneh; Mohammadi, Saber; Golchin, Mahdie; Sadeghi, Zargham; Moafi, Masoud; Seyed Mehdi, Seyed Mohammad

    2014-10-01

    During the past decade, incidence of asthma has increased, which might have been due to environmental exposures. Considering the expansion of cable manufacturing industry in Iran, the present study was conducted to evaluate the prevalence of occupational asthma in a cable manufacturing company in Iran as well as its related factors. This study was conducted on employees of a cable manufacturing company in Yazd, Iran, in 2012. The workers were divided into two groups of exposure (to toluene diisocyanate, polyvinyl chloride, polyethylene or polypropylene) and without exposure. Diagnosis of occupational asthma was made based on the subjects' medical history, spirometry and peak flowmetry, and its frequency was compared between the two groups. The overall prevalence of occupational asthma was 9.7%. This rate was 13.8% in the exposed group. Logistic regression analysis showed that even after adjustment for confounding factors, a significant correlation existed between the frequency of occupational asthma and exposure to the produced dust particles (P company workers in Iran, this issue needs to be addressed immediately in addition to reduction of exposure among subjects. Reduction in work shift duration, implementation of tobacco control and cessation programs for the personnel, and performing spirometry tests and respiratory examinations in shorter periods may be among effective measures for reducing the incidence of occupational asthma in this industry.

  13. Hybrid modeling for dynamic analysis of cable-pulley systems with time-varying length cable and its application

    Science.gov (United States)

    Wang, Jing; Qi, Zhaohui; Wang, Gang

    2017-10-01

    The dynamic analysis of cable-pulley systems is investigated in this paper, where the time-varying length characteristic of the cable as well as the coupling motion between the cable and the pulleys are considered. The dynamic model for cable-pulley systems are presented based on the principle of virtual power. Firstly, the cubic spline interpolation is adopted for modeling the flexible cable elements and the virtual 1powers of tensile strain, inertia and gravity forces on the cable are formulated. Then, the coupled motions between the cable and the movable or fixed pulley are described by the input and output contact points, based on the no-slip assumption and the spatial description. The virtual powers of inertia, gravity and applied forces on the contact segment of the cable, the movable and fixed pulleys are formulated. In particular, the internal node degrees of freedom of spline cable elements are reduced, which results in that only the independent description parameters of the nodes connected to the pulleys are included in the final governing dynamic equations. At last, two cable-pulley lifting mechanisms are considered as demonstrative application examples where the vibration of the lifting process is investigated. The comparison with ADAMS models is given to prove the validity of the proposed method.

  14. 47 CFR 1.1155 - Schedule of regulatory fees and filing locations for cable television services.

    Science.gov (United States)

    2010-10-01

    ... locations for cable television services. 1.1155 Section 1.1155 Telecommunication FEDERAL COMMUNICATIONS... Schedule of regulatory fees and filing locations for cable television services. Fee amount Address 1. Cable Television Relay Service $315 FCC, Cable, P.O. Box 979084, St. Louis, MO 63197-9000 2. Cable TV System (per...

  15. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator

    Science.gov (United States)

    Moses, Matthew S.; Murphy, Ryan J.; Kutzer, Michael D. M.; Armand, Mehran

    2016-01-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy. PMID:27818607

  16. Antenna mechanism of length control of actin cables

    CERN Document Server

    Mohapatra, Lishibanya; Kondev, Jane

    2014-01-01

    Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This antenna mechanism involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentra...

  17. Guy cable design and damping for vertical axis wind turbines

    Science.gov (United States)

    Carne, T. G.

    1981-01-01

    Guy cables are frequently used to support vertical axis wind turbines since guying the turbine reduces some of the structural requirements on the tower. The guys must be designed to provide both the required strength and the required stiffness at the top of the turbine. The axial load which the guys apply to the tower, bearings, and foundations is an undesirable consequence of using guys to support the turbine. Limiting the axial load so that it does not significantly affect the cost of the turbine is an important objective of the cable design. The lateral vibrations of the cables is another feature of the cable design which needs to be considered. These aspects of the cable design are discussed, and a technique for damping cable vibrations was mathematically analyzed and demonstrated with experimental data.

  18. Dynamic wind effects on suspension and cable-stayed bridges

    Science.gov (United States)

    Larsen, Allan; Larose, Guy L.

    2015-01-01

    Cable supported bridges are flexible structures which may be excited into oscillations by the wind. The excitation forces acting on cable supported bridges are aerodynamic by nature, but are for a large part set into play by the underlying structural dynamics of the bridge structures. The paper discusses the various types of dynamic wind effects commonly encountered for suspension and cable-stayed bridges emphasizing the importance of the structural dynamics.

  19. Distance Protection of Cross-Bonded Transmission Cable-Systems

    OpenAIRE

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable systems are being laid around the world. Differential protection is often used for the main protection of cables. As a backup protection, distance protection is very often the preferred choice. Therefore,...

  20. The Performance of Aircraft Control Cables Under Service Conditions

    Science.gov (United States)

    1976-04-01

    wires in the cables is illustr;tcd in Ifigs. I ald 2. Fatigue tests were also carried out on samples of galvanised steel cable (5 cwt. (2.49kN) minimumil...sheave ratio using the MIL-C-151I cable of 2.38 mm (3:32 in.) diameter would have been 13.3. For a satisfactory fatigue performance for 7 x 19 galvanised ...critical region in which cable life is relatively low". Reference 13 recommends a sheave ratio of 18 for 7 x 19 galvanised and stainless ,ables and a

  1. Strand critical current degradation in $Nb_{3}$ Sn Rutherford cables

    CERN Document Server

    Barzi, E; Higley, H C; Scanlan, R M; Yamada, R; Zlobin, A V

    2001-01-01

    Fermilab is developing 11 Tesla superconducting accelerator magnets based on Nb/sub 3/Sn superconductor. Multifilamentary Nb/sub 3/Sn strands produced using the modified jelly roll, internal tin, and powder-in-tube technologies were used for the development and test of the prototype cable. To optimize the cable geometry with respect to the critical current, short samples of Rutherford cable with packing factors in the 85 to 95% range were fabricated and studied. In this paper, the results of measurements of critical current, n-value and RRR made on the round virgin strands and on the strands extracted from the cable samples are presented. (5 refs).

  2. Simulations of a moored power cable at OBSEA platform

    OpenAIRE

    Prat Farran, Joana d'Arc; Río Fernandez, Joaquín del

    2013-01-01

    New green energy sources deployed at sea in mobile platforms use power cables in order to transport green energy at sea surface to the bottom. Theses power cables are exposed to the dynamic behaviour of the platform movements due to waves, currents and wind. OBSEA is a seafloor cabled observatory at 20 m depth in front of Vilanova, in Catalan coast. OBSEA captures data in real time like current, waves and wind among others. In this paper, a model of a moored power cable installed at OBS...

  3. A PSO Driven Intelligent Model Updating and Parameter Identification Scheme for Cable-Damper System

    Directory of Open Access Journals (Sweden)

    Danhui Dan

    2015-01-01

    Full Text Available The precise measurement of the cable force is very important for monitoring and evaluating the operation status of cable structures such as cable-stayed bridges. The cable system should be installed with lateral dampers to reduce the vibration, which affects the precise measurement of the cable force and other cable parameters. This paper suggests a cable model updating calculation scheme driven by the particle swarm optimization (PSO algorithm. By establishing a finite element model considering the static geometric nonlinearity and stress-stiffening effect firstly, an automatically finite element method model updating powered by PSO algorithm is proposed, with the aims to identify the cable force and relevant parameters of cable-damper system precisely. Both numerical case studies and full-scale cable tests indicated that, after two rounds of updating process, the algorithm can accurately identify the cable force, moment of inertia, and damping coefficient of the cable-damper system.

  4. 47 CFR 76.640 - Support for unidirectional digital cable products on digital cable systems.

    Science.gov (United States)

    2010-10-01

    ... Cable Network Interface Standard” (incorporated by reference, see § 76.602), provided however that with... reference, see § 76.602), when available from the content provider. With respect to in-band transport: (A... the transport stream. This twelve-hour period corresponds to delivery of the following event...

  5. 76 FR 77533 - Mandatory Electronic Filing for Cable Special Relief Petitions and Cable Show Cause Petitions...

    Science.gov (United States)

    2011-12-13

    ...: This document announces the implementation of electronic filing of Cable Special Relief (CSR) Petitions... filing of CSR and CSC petitions will be permitted through January 3, 2012, when electronic filing will... Tillery of the Media Bureau at (202) 418-1056. SUPPLEMENTARY INFORMATION: This is a summary of the CSR and...

  6. Kinetostatic Analysis of Cable-Driven Parallel Robots with Consideration of Sagging and Pulleys

    OpenAIRE

    Gouttefarde, Marc; Nguyen, Dinh Quan; Baradat, Cédric

    2014-01-01

    International audience; Cable-driven parallel robots manipulating heavy payloads typically use cables having non-negligible diameters and mass. The associated cable guiding pulleys may then have non-negligible radii whose influence on the robot kinematics can hardly be neglected. This paper focuses on the output pulleys from which the cables extend to the robot mobile platform. A kinetostatic analysis of cable-driven parallel robots considering both cable mass and output pulleys is presented.

  7. Two-way cable television project

    Science.gov (United States)

    Wilkens, H.; Guenther, P.; Kiel, F.; Kraus, F.; Mahnkopf, P.; Schnee, R.

    1982-02-01

    The market demand for a multiuser computer system with interactive services was studied. Mean system work load at peak use hours was estimated and the complexity of dialog with a central computer was determined. Man machine communication by broadband cable television transmission, using digital techniques, was assumed. The end to end system is described. It is user friendly, able to handle 10,000 subscribers, and provides color television display. The central computer system architecture with remote audiovisual terminals is depicted and software is explained. Signal transmission requirements are dealt with. International availability of the test system, including sample programs, is indicated.

  8. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    This paper describes shortly the status of superconducting transmission lines and assesses what impact the recently discovered BSCCO superconductors may have on the design of the cables.Two basically different insulation systems are discussed:1) The room temperature dielectric design, where...... the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept...

  9. Dynamic Loadability of Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt

    . Kinectrics is a large consultancy who employ, among others, one of the experts within loadability calculations, Dr. George Anders. During my stay, I obtained much insight i into dynamic rating techniques, practical issues with loadability calculations and the mathematics behind. During the PhD project I...... supervised 2 master projects, as well as 5 special courses at DTU. Furthermore I created and taught a cable course, with approximately 25 students, throughout 13 weeks during the spring of 2011. The PhD project has until now contributed with 3 journal papers and 4 conference papers. Selected papers can...

  10. Experimental Investigation of Aerodynamic Instability of Iced Bridge Cable Sections

    DEFF Research Database (Denmark)

    Koss, Holger; Lund, Mia Schou Møller

    2013-01-01

    of bridge cables under wind action. This paper describes the experimental simulation of ice accretion on a real bridge cable sheet HDPE tube segment (diameter 160mm) and its effect on the aerodynamic load. Furthermore, aerodynamic instability will be estimated with quasi-steady theory using the determined...

  11. Vortex-Induced Vibration of a Cable-Stayed Bridge

    Directory of Open Access Journals (Sweden)

    M. T. Song

    2016-01-01

    Full Text Available The dynamic response of a cable-stayed bridge that consists of a simply supported four-cable-stayed deck beam and two rigid towers, subjected to a distributed vortex shedding force on the deck beam with a uniform rectangular cross section, is studied in this work. The cable-stayed bridge is modeled as a continuous system, and the distributed vortex shedding force on the deck beam is modeled using Ehsan-Scanlan’s model. Orthogonality conditions of exact mode shapes of the linearized undamped cable-stayed bridge model are employed to convert coupled governing partial differential equations of the original cable-stayed bridge model with damping to a set of ordinary differential equations by using Galerkin method. The dynamic response of the cable-stayed bridge is calculated using Runge-Kutta-Felhberg method in MATLAB for two cases with and without geometric nonlinear terms. Convergence of the dynamic response from Galerkin method is investigated. Numerical results show that the geometric nonlinearities of stay cables have significant influence on vortex-induced vibration of the cable-stayed bridge. There are different limit cycles in the case of neglecting the geometric nonlinear terms, and there are only one limit cycle and chaotic responses in the case of considering the geometric nonlinear terms.

  12. Levitation of Superconductive Cable in Earth Magnetic Field

    Directory of Open Access Journals (Sweden)

    Pavel Karban

    2006-01-01

    Full Text Available The paper represents an introductory study about a superconductive cable levitating in Earth’s magnetic field. Built are two mathematical models of the problem providing both the shape of the arc of the cable and forces acting along it. The theoretical analysis is supplemented with an illustrative example.

  13. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended for...

  14. Low Friction Cryostat for HTS Power Cable of Dutch Project

    DEFF Research Database (Denmark)

    Chevtchenko, Oleg; Zuijderduin, Roy; Smit, Johan

    2012-01-01

    . A flexible dummy HTS cable was inserted into this cryostat and sub-cooled liquid nitrogen was circulated in the annulus between the dummy cable surface and the inner cryostat surface. In the paper details are presented of the cryostat, of the measurement setup, of the experiment and of the results....

  15. Chemical oxidation of cable insulating oil contaminated soil

    NARCIS (Netherlands)

    Jinlan Xu,; Pancras, T.; Grotenhuis, J.T.C.

    2011-01-01

    Leaking cable insulating oil is a common source of soil contamination of high-voltage underground electricity cables in many European countries. In situ remediation of these contaminations is very difficult, due to the nature of the contamination and the high concentrations present. Chemical

  16. Critical Current Measurements of the Main LHC Superconducting Cables

    CERN Document Server

    Verweij, A P

    2007-01-01

    For the main dipole and quadrupole magnets of the LHC, CERN has ordered from industry about 7000 km of superconducting Nb-Ti Rutherford type cables, delivered between 1999 and 2005. The strands of these cables are produced by six different companies, and cabled on five different machines. In the framework of the US contribution to the LHC, BNL has been testing and analyzing the electrical properties of samples of these cables. The main purpose of these tests was to qualify the critical current of the entire cable production in the frame of the quality assurance program implemented by CERN to assure the overall strand and cable performances. In total more than 2100 cable samples have been evaluated at 4.3 K in terms of critical current $I_{C}$, n-value and the residual resistance ratio, RRR. This paper will present an overview of the results, and show the correlations of the critical current and n-value between virgin strands, extracted strands, and cables. Also described are correlations of $I_{C}$ measured a...

  17. Optimized and practical electrical joints for CORC type HTS cables

    CERN Document Server

    Mulder, T; van der Laan, D C; Mentink, M G T; Dhallé, M; ten Kate, H H J

    2015-01-01

    Within CERN the development of REBCO-CORC (Conductor On Round Core) type cables is pursued in view of possible application in future detector and accelerator magnets. An important issue is the design and qualification of terminations for connecting CORC cables mutually or to bus-bars. A termination design is envisaged that combines a simple manufacturing process with a lowest possible joint terminal resistance in the few nΩ range at 4.2 K, first for a single CORC cable and subsequently for CORC based Cable-in-Conduit Conductors. The investigation concerns the effect of tapering the CORC cable within the joint to form a staircase like geometry, which allows current to pass more directly from the copper joint casing to the inner REBCO layers of the CORC cable. Simulations have shown a substantial decrease in joint resistance at operating current in the case both CORC cable and joint casing are tapered. The CORC cable and new joint were tested at CERN. In this paper, some details of the new joint design, fabric...

  18. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  19. Metal flame spray coating protects electrical cables in extreme environment

    Science.gov (United States)

    Brady, R. D.; Fox, H. A.

    1967-01-01

    Metal flame spray coating prevents EMF measurement error in sheathed instrumentation cables which are externally attached to cylinders which were cooled on the inside, but exposed to gamma radiation on the outside. The coating provides a thermoconductive path for radiation induced high temperatures within the cables.

  20. Analyses Of High Voltage Transmission Cables In South Western ...

    African Journals Online (AJOL)

    This paper presents the report of an investigation of the electrical and structural integrity of overhead and underground electrical cables in the south western part of Nigeria. Overhead and underground transmission cables were collected around the Obafemi Awolowo University environment, melted and cast into cylindrical ...

  1. Modeling and simulation of HTS cables for scattering parameter analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Su Sik; Lee, Geon Seok; Kwon, Gu-Young; Lee, Yeong Ho; Chang, Seung Jin; Lee, Chun-Kwon [School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03772 (Korea, Republic of); Sohn, Songho; Park, Kijun [Korea Electric Power Corporation Research Institute, Daejeon, 34056 (Korea, Republic of); Shin, Yong-June, E-mail: yongjune@yonsei.ac.kr [School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03772 (Korea, Republic of)

    2016-11-15

    Most of modeling and simulation of high temperature superconducting (HTS) cables are inadequate for high frequency analysis since focus of the simulation’s frequency is fundamental frequency of the power grid, which does not reflect transient characteristic. However, high frequency analysis is essential process to research the HTS cables transient for protection and diagnosis of the HTS cables. Thus, this paper proposes a new approach for modeling and simulation of HTS cables to derive the scattering parameter (S-parameter), an effective high frequency analysis, for transient wave propagation characteristics in high frequency range. The parameters sweeping method is used to validate the simulation results to the measured data given by a network analyzer (NA). This paper also presents the effects of the cable-to-NA connector in order to minimize the error between the simulated and the measured data under ambient and superconductive conditions. Based on the proposed modeling and simulation technique, S-parameters of long-distance HTS cables can be accurately derived in wide range of frequency. The results of proposed modeling and simulation can yield the characteristics of the HTS cables and will contribute to analyze the HTS cables.

  2. Double Layered Sheath in Accurate HV XLPE Cable Modeling

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Silva, J. De; Bak, Claus Leth

    2010-01-01

    This paper discusses modelling of high voltage AC underground cables. For long cables, when crossbonding points are present, not only the coaxial mode of propagation is excited during transient phenomena, but also the intersheath mode. This causes inaccurate simulation results for high frequency...

  3. Cable route optimization for offshore wind farms in morphodynamic areas

    NARCIS (Netherlands)

    Roetert, T.J.; Raaijmakers, T.; Borsje, Bastiaan Wijnand

    2017-01-01

    The aim of this paper is to optimize power cable routing in a wind farm based on the expected morphological behaviour in the design lifetime of an offshore wind farm. Up to now methods to optimize cable route layout in offshore wind farms are only based on a flat seabed and do not take the seabed

  4. Surface Plasmons in Coaxial Metamaterial Cables

    Science.gov (United States)

    Kushwaha, Manvir S.; Djafari-Rouhani, Bahram

    2013-07-01

    Thanks to Victor Veselago for his hypothesis of negative index of refraction, meta-materials — engineered composites — can be designed to have properties difficult or impossible to find in nature: they can have both electrical permittivity (ɛ) and magnetic permeability (μ) simultaneously negative. The metamaterials — henceforth negative-index materials (NIMs) — owe their properties to subwavelength structure rather than to their chemical composition. The tailored electromagnetic response of the NIMs has had a dramatic impact on classical optics: they are becoming known to have changed many basic notions related with electromagnetism. The present article is focused on gathering and reviewing fundamental characteristics of plasmon propagation in coaxial cables fabricated of the right-handed medium (RHM) (with ɛ > 0, μ > 0) and the left-handed medium (LHM) (with ɛ cloaking devices in particular. A recent surge in efforts on invisibility and the cloaking devices seems to have spoiled the researchers worldwide: proposals include not only a way to hide an object without having to wrap the cloak around it, but also to replace a given object with another, thus adding to the deception even further! All this is attributed as much to the fundamental as to the practical advances made in the fabrication and characterization of NIMs. The article concludes briefly addressing the anticipated implications of plasmon observation in the multicoaxial cables and suggesting future dimensions worth adding to the problem. The background provided is believed to make less formidable the task of future writers of reviews in this field.

  5. Losses in armoured three-phase submarine cables

    DEFF Research Database (Denmark)

    Ebdrup, Thomas; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2014-01-01

    increases the losses in armoured cables compared to unarmoured cables. In this paper a thorough state of the art analysis is conducted on armour losses in three-phase armoured submarine power cables. The analysis shows that the IEC 60287-1-1 standard overestimates the armour losses which lead...... to the installation of cables with excessive phase conductor cross section. This paper also presents an example of the potential economic benefits of having a better knowledge of the losses introduced by the armour.......The number of offshore wind farms will keep increasing in the future as a part of the shift towards a CO2 free energy production. The energy harvested from the wind farm must be brought to shore, which is often done by using a three-phase armoured submarine power cable. The use of an armour...

  6. The Offshore Wind Farm Array Cable Layout Problem

    DEFF Research Database (Denmark)

    Bauer, Joanna; Lysgaard, Jens

    2014-01-01

    In an offshore wind farm (OWF), the turbines are connected to a transformer by cable routes that cannot cross each other. Finding the minimum cost array cable layout thus amounts to a vehicle routing problem with the additional constraints that the routes must be embedded in the plane. For this p......In an offshore wind farm (OWF), the turbines are connected to a transformer by cable routes that cannot cross each other. Finding the minimum cost array cable layout thus amounts to a vehicle routing problem with the additional constraints that the routes must be embedded in the plane....... For this problem, both exact and heuristic methods are of interest. We optimize cable layouts for real-world OWFs by a hop-indexed integer programming formulation, and develop a heuristic for computing layouts based on the Clarke and Wright savings heuristic for vehicle routing. Our heuristic computes layouts...

  7. Non-Intrusive Impedance-Based Cable Tester

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A non-intrusive electrical cable tester determines the nature and location of a discontinuity in a cable through application of an oscillating signal to one end of the cable. The frequency of the oscillating signal is varied in increments until a minimum, close to zero voltage is measured at a signal injection point which is indicative of a minimum impedance at that point. The frequency of the test signal at which the minimum impedance occurs is then employed to determine the distance to the discontinuity by employing a formula which relates this distance to the signal frequency and the velocity factor of the cable. A numerically controlled oscillator is provided to generate the oscillating signal, and a microcontroller automatically controls operation of the cable tester to make the desired measurements and display the results. The device is contained in a portable housing which may be hand held to facilitate convenient use of the device in difficult to access locations.

  8. First International Conference on Cable-Driven Parallel Robots

    CERN Document Server

    Pott, Andreas; Cable-Driven Parallel Robots

    2013-01-01

    This publication presents the outcome of the "First International Conference on Cable-Driven Parallel Robots" in 2012. This is the first conference to bring together the cable robot community and dedicate a forum for the international experts of this field. It contains the Know-how, ideas and experiences of active researchers developing cable-driven robots. The book presents the state of the art, including summarizing contributions and latest research results and, where relevant, the future outlook. The book covers the essential topics for cable-driven robots: classification and definition, kinematics, workspace analysis, cable modeling, control and calibration, design methodology, hardware/prototype development, experimental evaluation, application reports and new application concepts.

  9. Life-assessment technique for nuclear power plant cables

    Energy Technology Data Exchange (ETDEWEB)

    Bartonicek, B.; Hnat, V.; Placek, V

    1998-06-01

    The condition of polymer-based cable material can be best characterized by measuring elongation at break of its insulating materials. However, it is not often possible to take sufficiently large samples for measurement with the tensile testing machine. The problem has been conveniently solved by utilizing differential scanning calorimetry technique. From the tested cable, several microsamples are taken and the oxidation induction time (OIT) is determined. For each cable which is subject to the assessment of the lifetime, the correlation of OIT with elongation at break and the correlation of elongation at break with the cable service time has to be performed. A reliable assessment of the cable lifetime depends on accuracy of these correlations. Consequently, synergistic effects well known at this time - dose rate effects and effects resulting from the different sequence of applying radiation and elevated temperature must be taken into account.

  10. Ground Loop Impedance of Long EHV Cable Lines

    DEFF Research Database (Denmark)

    Ohno, Teruo; Bak, Claus Leth; Sørensen, Thomas K.

    2012-01-01

    The distance protection scheme without communication is often applied to the backup protection of EHV cable lines. For a reliable operation of a ground distance relay, the ground loop impedance of EHV cable lines needs to have a linear relationship to the distance from the relay location...... to the fault location. The discontinuity of the ground loop impedance at cross-bonding points may have an ill effect on the reliable operation of the ground distance relay. However, the cause and parameters of the discontinuity and its effects on the ground distance relay protection have not been discussed...... in literature. Through the calculation of the ground loop impedance for cable lines, it has been found that, for long EHV cable lines, the reliable operation of the ground distance relay is possible with a typical relay setting. Effects of parameters, such as substation grounding, cable layouts...

  11. A dc transmission cable prototype using high-temperature superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Beales, T.P.; Friend, C.M. [BICC Cables Ltd, Hedgeley Road, Hebburn, Tyne and Wear NE31 1XR (United Kingdom); Segir, W.; Ferrero, E. [Ceat Cavi Industrie srl, Via Brescia 16, 10036 Settimo Torinese (Italy); Vivaldi, F.; Ottonello, L. [Ansaldo Ricerche srl, Corso Perrone 25, 16161 Genoa (Italy)

    1996-01-01

    This paper gives the results from a recent collaboration between BICC Cables Ltd, its Italian subsidiary Ceat Cavi srl, and Ansaldo Ricerche srl on the design and testing of a high-temperature superconducting dc transmission cable prototype. The cable was designed to carry 10 000 A at 40 kV, operating at 40 K. Qualification testing was carried out from 4.2 K up to 40 K. At an operating temperature of 31 K the prototype cable had a current capacity of 11 067 A (the largest dc current reported in a high-temperature prototype to date), which represents a tenfold increase in current over a conventional 1000 mm{sup 2} copper cable. (author)

  12. Potential Impact of Submarine Power Cables on Crab Harvest

    Science.gov (United States)

    Bull, A. S.; Nishimoto, M.

    2016-02-01

    Offshore renewable energy installations convert wave or wind energy to electricity and transfer the power to shore through transmission cables laid on or buried beneath the seafloor. West coast commercial fishermen, who harvest the highly prized Dungeness crab (Metacarcinus magister) and the rock crab (Cancer spp.), are concerned that the interface of crabs and electromagnetic fields (EMF) from these cables will present an electrified fence on the seafloor that their target resource will not cross. Combined with the assistance of professional fishermen, submarine transmission cables that electrify island communities and offshore oil platforms in the eastern Pacific provide an opportunity to test the harvest of crab species across power transmission cables. In situ field techniques give commercial crab species a choice to decide if they will cross fully energized, EMF emitting, power transmission cables, in response to baited traps. Each independent trial is either one of two possible responses: the crab crosses the cable to enter a trap (1) or the crab does not cross the cable to enter a trap (0). Conditions vary among sample units by the following categorical, fixed factors (i.e., covariates) of cable structure (buried or unburied); direction of cable from crab position (west or east, north or south); time and season. A generalized linear model is fit to the data to determine whether any of these factors affect the probability of crabs crossing an energized cable to enter baited traps. Additionally, the experimental design, aside from the number of runs (set of sample trials) and the dates of the runs, is the same in the Santa Barbara Channel for rock crab and Puget Sound for Dungeness crab, and allows us to compare the capture rates of the two species in the two areas. We present preliminary results from field testing in 2015.

  13. Improved practical formulas for estimation of cable tension by vibration method; Shindoho ni yoru cable choryoku jitsuyo santeishiki no hosei

    Energy Technology Data Exchange (ETDEWEB)

    Zui, H. [Setsunan University, Osaka (Japan). Faculty of Engineering; Shinke, T. [Kobe Technical College, Kobe, Kobe (Japan); Hamazaki, Y. [Kobe Steel, Ltd., Kobe (Japan)

    1995-10-21

    The vibration method is usually utilized on the measurement of cable tension during construction of cable bridge such as Nielsen bridges or cable stayed bridges. Practical formula for the vibration method previously proposed by authors is often used where bending rigidity is taken into account. These formula, however, have a certain limit of application and do not yield good results when the cable is not slender or not enough mentioned. The practical formula is modified to improve the accuracy and new formulas are made. The new practical formulas are applicable to any cables, regardless of its length and tension in it. The accuracy is confirmed through comparison of the value obtained by practical formulas with measured values and calculated value by F.E.M. 2 refs., 4 figs., 1 tab.

  14. Design of anti-theft/cable cut real time alert system for copper cable using microcontroller and GSM technology

    Science.gov (United States)

    Lim, E. K.; Norizan, M. N.; Mohamad, I. S.; Yasin, M. N. M.; Murad, S. A. Z.; Baharum, N. A.; Jamalullail, N.

    2017-09-01

    This paper presents the design of anti-theft/cable cut real time alert system using microcontroller and GSM technology. The detection part is using the electrical circuit wire connection in detecting the voltage drop of the cable inside the microcontroller digital input port. The GSM wireless modem is used to send the location of cable cut directly to the authority mobile phone. Microcontroller SK40C with Microchip PIC16F887 is used as a controller to control the wireless modem and also the detection device. The device is able to detect and display the location of the cable cut on the LCD display besides of and sending out the location of the cable break to the authority mobile phone wirelessly via SMS.

  15. Aerodynamics of the cable of cable-stayed bridges; Shachokyo cable no kuriki shindo tokusei no rikai to soreni motozuku kuriki seishinho no teian

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, M. [Kyoto University, Kyoto (Japan). Faculty of Engineering; Aoki, J.; Fuji, D. [West Japan Railway Company, Osaka (Japan); Kitayama, N. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan); Daito, Y. [Kyoto University, Kyoto (Japan)

    1996-07-21

    Wind tunnel tests were conducted assuming the aerodynamics of the cable of cable-stayed bridges especially in the case of strong wind with rain. Based on the results, an aerodynamic damping method was proposed. Factors of the rain vibration generation include the three-dimensional axial flow behind the cable, which is formed by the wind direction deviation angle, the upper side water flow on the cable surface formed by the rain, and the Karman vortex shedding, which are not uniform in the span direction. Newly proposed cable with elliptical plates showed an effective dumping performance. It restrains the formation of water flow due to its profile, and is effective for unstableness due to water flow formation. Distribution of the axial flow in the cable span direction was made clear. Three-dimensionality of the vortex shedding was greatly affected by this axial flow. Frequency of the Karman vortex shedding changed in the wide band by the axial flow. It was suggested that three-dimensionality of the flow field is enhanced by the rolling vibration, resulting in the unstableness of heaving vibration. 5 refs., 15 figs.

  16. PCACE- PERSONAL COMPUTER AIDED CABLING ENGINEERING

    Science.gov (United States)

    Billitti, J. W.

    1994-01-01

    A computerized interactive harness engineering program has been developed to provide an inexpensive, interactive system which is designed for learning and using an engineering approach to interconnection systems. PCACE is basically a database system that stores information as files of individual connectors and handles wiring information in circuit groups stored as records. This directly emulates the typical manual engineering methods of data handling, thus making the user interface to the program very natural. Data files can be created, viewed, manipulated, or printed in real time. The printed ouput is in a form ready for use by fabrication and engineering personnel. PCACE also contains a wide variety of error-checking routines including connector contact checks during hardcopy generation. The user may edit existing harness data files or create new files. In creating a new file, the user is given the opportunity to insert all the connector and harness boiler plate data which would be part of a normal connector wiring diagram. This data includes the following: 1) connector reference designator, 2) connector part number, 3) backshell part number, 4) cable reference designator, 5) cable part number, 6) drawing revision, 7) relevant notes, 8) standard wire gauge, and 9) maximum circuit count. Any item except the maximum circuit count may be left blank, and any item may be changed at a later time. Once a file is created and organized, the user is directed to the main menu and has access to the file boiler plate, the circuit wiring records, and the wiring records index list. The organization of a file is such that record zero contains the connector/cable boiler plate, and all other records contain circuit wiring data. Each wiring record will handle a circuit with as many as nine wires in the interface. The record stores the circuit name and wire count and the following data for each wire: 1) wire identifier, 2) contact, 3) splice, 4) wire gauge if different from standard

  17. Longest cable-stayed bridge TATARA; Longest shachokyo Tatara Ohashi

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, K. [Hiroshima University, Hiroshima (Japan). Faculty of Engineering

    1998-06-15

    The world`s longest cable-stayed bridge Tatara having a central span of 890 m had the both ends closed in August 1997, linking Namakuchi Island and Omishima Island. Final finishing work is continuing for opening of the West Seto Expressway in the spring of 1999. A cable-stayed bridge supports the bridge girders by perpendicular components of tensile force of cables stayed obliquely. On the other hand, there is a concern that the girders may have axial compression force generated due to horizontal components of the force from the cable tensile force, which can cause buckling of the girders. Therefore, in order to suspend the girders efficiently by increasing the perpendicular components of the cable force, and moreover to suppress the axial compression force on the girders, it is more advantageous to make bridge towers high, hence the towers of this bridge are highest among the bridges on the Shimanami Ocean Road. This bridge whose long girders are stayed with 21-stage multi cables presented a problem in designing the buckling in steel girders near the towers due to the horizontal components of the force generated by the bridge. Discussions were given, therefore, by using load withstanding force experiments using a whole bridge model of 1/50 scale, buckling experiments on full-size reinforcing plate models, and load withstanding force analysis using a tower model. A number of other technical discussions were repeated, by which the world`s longest cable-stayed bridge was completed. 9 figs., 1 tab.

  18. Antenna Mechanism of Length Control of Actin Cables.

    Directory of Open Access Journals (Sweden)

    Lishibanya Mohapatra

    2015-06-01

    Full Text Available Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This "antenna mechanism" involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentration of myosin motors delivering Smy1. These results provide testable predictions of the antenna mechanism of actin-cable length control.

  19. Current distribution in Cable-In-Conduit Conductors

    Energy Technology Data Exchange (ETDEWEB)

    Ferri, M.A.

    1994-05-01

    A numerical study of the current distribution in Cable-In-Conduit Conductors (CICC`s) experiencing linearly ramping transport currents and transverse magnetic fields was conducted for both infinitely long, periodic cables and finite length cables terminated in low resistance joints. The goal of the study was to gain insight into the phenomenon known as Ramp Rate Limitation, an as yet unexplained correspondence between maximum attainable current and the ramp time taken to reach that current in CICC superconducting magnets. A discrete geometric model of a 27 strand multiply twisted CICC was developed to effectively represent the flux linkages, mutual inductances, and resistive contact points between the strands of an experimentally tested cable. The results of the numerical study showed that for fully periodic cables, the current imbalances due to ramping magnetic fields and ramping transport currents are negligible in the range of experimentally explored operating conditions. For finite length, joint terminated cables, however, significant imbalances can exist. Unfortunately, quantitative results are limited by a lack of knowledge of the transverse resistance between strands in the joints. Nonetheless, general results are presented showing the dependency of the imbalance on cable length, ramp time, and joint resistance for both ramping transverse magnet fields and ramping transport currents. At the conclusion of the study, it is suggested that calculated current imbalances in a finite length cable could cause certain strands to prematurely ``quench`` -- become non-superconducting --thus leading to an instability for the entire cable. This numerically predicted ``current imbalance instability`` is compared to the experimentally observed Ramp Rate Limitation for the 27 strand CICC sample.

  20. Low AC Loss in a 3 kA HTS Cable of the Dutch Project

    NARCIS (Netherlands)

    Chevtchenko, O.; Zuijderduin, R.; Smit, J.; Willen, D.; Lentge, H.; Thidemann, C.; Traeholt, C.; Melnik, I.; Geschiere, A.

    2012-01-01

    are: a cable has to fit in an annulus of 160 mm, with two cooling stations at the cable ends only. Existing solutions for HTS cables would lead to excessively high coolant pressure drop in the cable, potentially affecting public acceptance of the project. A way out would be to substantially reduce

  1. HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV

    Directory of Open Access Journals (Sweden)

    T.Yu. Antonets

    2015-12-01

    Full Text Available In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables. Tests to heat of cables for XLPE-polyethylene are used as a solid dielectric insulation. The line to XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. When single-core cables are installed in parallel the load current may not share equally between the parallel cables. This is because a significant proportion of the impedance of large conductors is due to self reactance and mutual reactance. Hence the spacing and relative location of each cable will have an effect on the current sharing. Calculation for each cable configuration is necessary. Possibility of using for determining the thermal properties of XLPE-cables a sheath applied over the cable surface with coefficient convection heat transfer between cable surface and the air region about it of equal zero. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

  2. 47 CFR 76.611 - Cable television basic signal leakage performance criteria.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television basic signal leakage...) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76.611 Cable television basic signal leakage performance criteria. (a) No cable television system shall commence or...

  3. Numerical Modeling of Physic-Chemical Processes of Multicore Cable in the Polymerization

    Directory of Open Access Journals (Sweden)

    Abramova A.V.

    2015-01-01

    Full Text Available There are developed mathematical model of physical and chemical processes of polymerization adhesive coating stranded cable. There are found time of full polymerization in the shell of the multicore cable product. There are compared with the single-core cable. Also the necessity of changing the speed of the cable pulling the multilayer product compared with single-core.

  4. 47 CFR 76.905 - Standards for identification of cable systems subject to effective competition.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Standards for identification of cable systems... Regulation § 76.905 Standards for identification of cable systems subject to effective competition. (a) Only the rates of cable systems that are not subject to effective competition may be regulated. (b) A cable...

  5. Comparison of several innovative bridge cable surface modifications

    DEFF Research Database (Denmark)

    Kleissl, Kenneth; Georgakis, Christos T.

    Over the last two decades, several bridge cable manufacturers have introduced surface modifications on the high-density polyethylene (HDPE) sheathing that is installed for the protection of inner cable strands or wires. The modifications are based on research undertaken predominantly in Europe...... and Japan, with two different prevailing systems: HDPE tubing fitted with helical fillets and tubing with pattern-indented surfaces. In the US and Europe, helical fillets dominate, whilst pattern indented sur-faces are more common in Asia, particularly for long-span cable-stayed bridges. Research...

  6. Cable fire risk of a nuclear power plant; Ydinvoimalaitoksen kaapelipaloriski

    Energy Technology Data Exchange (ETDEWEB)

    Aulamo, H.

    1998-02-01

    The aim of the study is to carry out a comprehensive review of cable fire risk issues of nuclear power plants (NPP) taking into account latest fire and risk assessment research results. A special emphasis is put on considering the fire risk analysis of cable rooms in the framework of TVO Olkiluoto NPP probabilistic safety assessment. The assumptions made in the analysis are assessed. The literature study section considers significant fire events at nuclear power plants, the most severe of which have nearly led to a reactor core damage (Browns Ferry, Greifswald, Armenia, Belojarsk, Narora). Cable fire research results are also examined. 62 refs.

  7. High-Density Optical Cable For Public Communications

    Science.gov (United States)

    Trunk, Jonas; Monteiro, Ricardo

    1988-02-01

    Optical fiber networks for public communications are moving toward the subscribers and therefore feeder optical cables with relative great amount of fibers are needed. A 120 fibers cable has been designed with ten UV curable acrilate coated fibers accommodate together inside each plastic loose tube, and twelve these tubes are stranded around a central strength member resulting in a high packaging density construction. A cable prototipe has been manufactured and some tests was made under conditions which simulate the situations found during installation and after due to hostile environments.

  8. Arc tracking energy balance for copper and aluminum aeronautic cables

    Science.gov (United States)

    André, T.; Valensi, F.; Teulet, P.; Cressault, Y.; Zink, T.; Caussé, R.

    2017-04-01

    Arc tracking tests have been carried out between two voluntarily damaged aeronautic cables. Copper or aluminum conductors have been exposed to short circuits under alternating current. Various data have been recorded (arc voltage and current, radiated power and ablated mass), enabling to determine a power balance, in which every contribution is estimated. The total power is mainly transferred to the cables (between 50 and 65%, depending on the current and the cable type), and causes the melting and partial vaporization of the metallic core and insulating material, or is conducted or radiated. The other part is deposited into the arc column, being either radiated, convected or conducted.

  9. Cable Damage Detection System and Algorithms Using Time Domain Reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G A; Robbins, C L; Wade, K A; Souza, P R

    2009-03-24

    This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model

  10. Cubierta de doble curvatura de cables pretensados (Finlandia

    Directory of Open Access Journals (Sweden)

    Bergholt, K.

    1966-03-01

    Full Text Available A new ice hockey stadium has been built in Tampere, Finland. It has a reinforced concrete structure and a light, double curvature, roof suspended from a network of prestressed cables. It has a rectangular planform, 63x92 m, and it can accommodate 10,000 spectators. The hockey rink is in the centre. After a brief comparison of various types of suspended roofs, the author describes his own design, and discusses the most delicate aspects of the project. The cables are anchored in lateral arched beams, whose stability is provided by external prestressed concrete ribs. The author emphasizes the importance of these beams for the overall efficiency of the project. Special care was taken to avoid curvature of the cables where these penetrate into the lateral beams, without, however, restricting the freedom of the cables to oscillate. The article describes the placing of the cables, the details of the cables themselves, and their stretching: all of which is a technology that is now well know and tried.El nuevo estadio para hockey sobre hielo, construido, en Tampere, Finlandia, a base de una estructura en hormigón armado y una cubierta ligera de doble curvatura formada por una red de cables pretensados, tiene forma rectangular con planta de 63,2 x 92 m; está previsto para 10.000 espectadores y lleva en el centro la cancha para hockey. Después de una ligera comparación de los distintos tipos de cubiertas suspendidas, el autor describe su obra y analiza las partes más sensibles de la cubierta suspendida por él proyectada. Los cables están anclados en vigas o arcos laterales cuya estabilidad está asegurada por tirantes exteriores de hormigón pretensado. El autor subraya la particular importancia que tiene la concepción de estas vigas o arcos laterales para la economía de la obra. Se tuvo especial cuidado en evitar codos en los cables donde éstos entran en las vigas o arcos laterales, sin por eso restringa la necesaria libertad de movimiento de

  11. Sediment Biogeochemistry After the Entrance of Cable Bacteria

    DEFF Research Database (Denmark)

    Risgaard-Petersen, Nils

    , sulfide-rich coastal sediments, salt marshes seasonally hypoxic basins, subtidal coastal mud plains, as well as freshwater sediments and waterlogged soils. In this talk I will review our current knowledge on how cable bacteria influence the biogeochemistry of sediments. The cable bacteria form electric...... and the formation of sulfate[3] Field studies conducted in the marine environment indicate that some of these effects are expressed in a way that marine systems with active cable bacteria populations have elevated phosphorus-retention{Sulu-Gambari, 2016 #1501} and acts as strong buffers against adverse stage...

  12. Simultaneous Thermal and Gamma Radiation Aging of Cable Polymers

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S.; Liu, Shuaishuai; Bowler, Nicola

    2016-12-19

    Polymers used in nuclear power plant electrical cable systems experience aging and degradation over time due to environmental stress including heat and gamma irradiation. Prediction of long-term cable performance has been based on results of short-term accelerated laboratory aging studies, but questions remain regarding the correlation of accelerated aging to long-term, in-plant aging. This work seeks to increase understanding of the combined effects of heat and radiation on cable polymer material aging toward addressing these questions.

  13. Fiber Optic Cable Thermal Preparation to Ensure Stable Operation

    Science.gov (United States)

    Thoames Jr, William J.; Chuska, Rick F.; LaRocca, Frank V.; Switzer, Robert C.; Macmurphy, Shawn L.; Ott, Melanie N.

    2008-01-01

    Fiber optic cables are widely used in modern systems that must provide stable operation during exposure to changing environmental conditions. For example, a fiber optic cable on a satellite may have to reliably function over a temperature range of -50 C up to 125 C. While the system requirements for a particular application will dictate the exact method by which the fibers should be prepared, this work will examine multiple ruggedized fibers prepared in different fashions and subjected to thermal qualification testing. The data show that if properly conditioned the fiber cables can provide stable operation, but if done incorrectly, they will have large fluctuations in transmission.

  14. A preliminary bending fatigue spectrum for steel monostrand cables

    DEFF Research Database (Denmark)

    Winkler, Jan; Fischer, Gregor; Georgakis, Christos T.

    2011-01-01

    This paper presents the results of the experimental study on the bending fatigue resistance of high-strength steel monostrand cables. From the conducted fatigue tests in the high-stress, low-cycle region, a preliminary bending fatigue spectrum is derived for the estimation of monostrand cable...... service life expectancy. The presented preliminary bending fatigue spectrum of high-strength monostrands is currently unavailable in the published literature. The presented results provide relevant information on the bending mechanism and fatigue characteristics of monostrand steel cables in tension...

  15. Aerodynamic instability of cables in transmission power lines; Inestabilidad aerodinamica en cables de lineas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Lopez, Alberto; Vilar Rojas, Jorge Ivan; Munoz Black, Celso J. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    One of the aerodynamic instabilities of transmission power lines cables is galloping, which consists in the appearance of important cable vibrations, mainly when the wind hits orthogonally the power line. In some cases the maximum amplitude that occurs reaches several meters, even when the wind velocities in a region are well below the value used for the mechanical design of the power lines. In general terms, galloping is associated with particular climatic conditions such as low temperatures and high humidities. In these conditions a coating of ice that adheres to the cable is formed, changing its transverse cross section, propitiating the galloping, although some authors have reported galloping without ice. These climatic conditions are presented mainly in the Northern part of our country and in the high regions of the mountain zones; nevertheless, the galloping phenomenon has been reported in few cases by Comision Federal de Electricidad (CFE). The possible expansion of the power lines in these regions of the country leads to prevent the measures needed to diminish the appearance of this phenomenon. In this paper mention is made in particular of the solution adopted to the galloping problem that has appeared in the transmission power line of Salamayuca to Reforma, Ciudad Juarez, Chihuahua (CFE,1991). [Espanol] Una de las inestabilidades aerodinamicas que se presentan en los cables de lineas de transmision es el galopeo, el cual consiste en la aparicion de vibraciones importantes de los cables, sobre todo cuando el flujo del viento incide ortogonalmente a la linea. En algunos casos las amplitudes maximas que se presentan llegan a ser de varios metros, aun cuando las velocidades del viento en una region esten muy por debajo del valor empleado para el diseno mecanico de las lineas. Generalmente, el galopeo se asocia con condiciones climaticas particulares como son las bajas temperaturas y altas humedades. En estas condiciones se forma una cubierta de hielo que se

  16. Impact of Cross-Tie Properties on the Modal Behavior of Cable Networks on Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    Javaid Ahmad

    2015-01-01

    Full Text Available Dynamic behaviour of cable networks is highly dependent on the installation location, stiffness, and damping of cross-ties. Thus, these are the important design parameters for a cable network. While the effects of the former two on the network response have been investigated to some extent in the past, the impact of cross-tie damping has rarely been addressed. To comprehend our knowledge of mechanics associated with cable networks, in the current study, an analytical model of a cable network will be proposed by taking into account both cross-tie stiffness and damping. In addition, the damping property of main cables in the network will also be considered in the formulation. This would allow exploring not only the effectiveness of a cross-tie design on enhancing the in-plane stiffness of a constituted cable network, but also its energy dissipation capacity. The proposed analytical model will be applied to networks with different configurations. The influence of cross-tie stiffness and damping on the modal response of various types of networks will be investigated by using the corresponding undamped rigid cross-tie network as a reference base. Results will provide valuable information on the selection of cross-tie properties to achieve more effective cable vibration control.

  17. Impact of Cross-Tie Properties on the Modal Behavior of Cable Networks on Cable-Stayed Bridges.

    Science.gov (United States)

    Ahmad, Javaid; Cheng, Shaohong; Ghrib, Faouzi

    2015-01-01

    Dynamic behaviour of cable networks is highly dependent on the installation location, stiffness, and damping of cross-ties. Thus, these are the important design parameters for a cable network. While the effects of the former two on the network response have been investigated to some extent in the past, the impact of cross-tie damping has rarely been addressed. To comprehend our knowledge of mechanics associated with cable networks, in the current study, an analytical model of a cable network will be proposed by taking into account both cross-tie stiffness and damping. In addition, the damping property of main cables in the network will also be considered in the formulation. This would allow exploring not only the effectiveness of a cross-tie design on enhancing the in-plane stiffness of a constituted cable network, but also its energy dissipation capacity. The proposed analytical model will be applied to networks with different configurations. The influence of cross-tie stiffness and damping on the modal response of various types of networks will be investigated by using the corresponding undamped rigid cross-tie network as a reference base. Results will provide valuable information on the selection of cross-tie properties to achieve more effective cable vibration control.

  18. Simple Program to Investigate Hysteresis Damping Effect of Cross-Ties on Cables Vibration of Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    Panagis G. Papadopoulos

    2012-01-01

    Full Text Available A short computer program, fully documented, is presented, for the step-by-step dynamic analysis of isolated cables or couples of parallel cables of a cable-stayed bridge, connected to each other and possibly with the deck of the bridge, by very thin pretensioned wires (cross-ties and subjected to variation of their axial forces due to traffic or to successive pulses of a wind drag force. A simplified SDOF model, approximating the fundamental vibration mode, is adopted for every individual cable. The geometric nonlinearity of the cables is taken into account by their geometric stiffness, whereas the material nonlinearities of the cross-ties include compressive loosening, tensile yielding, and hysteresis stress-strain loops. Seven numerical experiments are performed. Based on them, it is observed that if two interconnected parallel cables have different dynamic characteristics, for example different lengths, thus different masses, weights, and geometric stiffnesses, too, or if one of them has a small additional mass, then a single pretensioned very thin wire, connecting them to each other and possibly with the deck of the bridge, proves effective in suppressing, by its hysteresis damping, the vibrations of the cables.

  19. SC Power leads and cables - Nominal Current Test Performance of 2 kA-Class High-Tc Superconducting Cable Conductors and Its Implications for Cooling Systems for Utility Cables

    DEFF Research Database (Denmark)

    Willen, D. W. A; Daumling, M.; Rasmussen, C. N.

    2000-01-01

    configurations. The conductors are characterised under dc and ac conditions. The current and voltage is recorded during the tests in order to determine the impedances and the losses of the cable models. Using a phase-sensitive measurement with two lock-in amplifiers, small losses can be accurately measured...... individual layers in the cables saturate. The loss-contributions from other components of the cable system are discussed,and the implications for the cooling apparatus for superconducting utility cables are determined....

  20. Switching studies for the Horns Rev 2 wind farm main cable

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Faria da Silva, Filipe; Bak, Claus Leth

    2011-01-01

    sections with a total length of 57.7 km and a 42 km long submarine cable. The submarine cable is a three phase type of cable, and three single conductor cables are used for the land cable. Methods of recalculating the physical cable parameters, given in the data sheet, to parameters suitable for the cable......This article proposes a method of constructing a PSCAD model suitable for switching studies in a system containing long HVAC cables. The transmission network connection to the 215 MW offshore wind farm Horns Rev 2 is used as a case study. The connection to Horns Rev 2 consists of two land cable......, and the use of different cable models....

  1. On the stiffness analysis of a cable driven leg exoskeleton.

    Science.gov (United States)

    Sanjeevi, N S S; Vashista, Vineet

    2017-07-01

    Robotic systems are being used for gait rehabilitation of patients with neurological disorder. These devices are externally powered to apply external forces on human limbs to assist the leg motion. Patients while walking with these devices adapt their walking pattern in response to the applied forces. The efficacy of a rehabilitation paradigm thus depends on the human-robot interaction. A cable driven leg exoskeleton (CDLE) use actuated cables to apply external joint torques on human leg. Cables are lightweight and flexible but can only be pulled, thus a CDLE requires redundant cables. Redundancy in CDLE can be utilized to appropriately tune a robot's performance. In this work, we present the stiffness analysis of CDLE. Different stiffness performance indices are established to study the role of system parameters in improving the human-robot interaction.

  2. Wind-induced vibration of stay cables : brief

    Science.gov (United States)

    2005-02-01

    The objectives of this project were to: : Identify gaps in current knowledge base : Conduct analytical and experimental research in critical areas : Study performance of existing cable-stayed bridges : Study current mitigation methods...

  3. Dynamic properties of stay cables on the Penobscot Narrows bridge.

    Science.gov (United States)

    2014-09-01

    Cable-stayed bridges have been recognized as the most efficient and cost effective structural form for medium to long : span bridges over the past several decades. With their widespread use, cases of serviceability problems associated with : large am...

  4. Plastic molds reduce cost of encapsulating electric cable connectors

    Science.gov (United States)

    Knott, D.

    1964-01-01

    Resin casting of the aluminum master pattern forms a plastic mold for encapsulating a cable connector. An elastomer is injected into the mold and cured. The mold is disassembled leaving an elastomeric encapsulation around the connector.

  5. The Electrical Resistance of Rutherford-Type Superconducting Cable Splices

    CERN Document Server

    Heck, C; Fleiter, J; Bottura, L

    2015-01-01

    The electrical resistance of Large Hadron Collider main busbar cable lap splices produced by soft soldering has been measured with two independent methods as a function of intercable contact area and for splices made of cables with various defects. For defect-free lap splices, the resistance increases from 0.3 to 10 nΩ (at 4.3 K in self-field) when reducing the cable overlap length from 120 to 3 mm, as expected assuming that the resistance is inversely proportional to the intercable contact area. The resistance of bridge splices that connect side-by-side cables can be predicted from the lap splice resistances and the overlap areas involved.

  6. Application of Superconducting Power Cables to DC Electric Railway Systems

    Science.gov (United States)

    Ohsaki, Hiroyuki; Lv, Zhen; Sekino, Masaki; Tomita, Masaru

    For novel design and efficient operation of next-generation DC electric railway systems, especially for their substantial energy saving, we have studied the feasibility of applying superconducting power cables to them. In this paper it is assumed that a superconducting power cable is applied to connect substations supplying electric power to trains. An analysis model line was described by an electric circuit, which was analyzed with MATLAB-Simulink. From the calculated voltages and currents of the circuit, the regenerative brake and the energy losses were estimated. In addition, assuming the heat loads of superconducting power cables and the cryogenic efficiency, the energy saving of the total system was evaluated. The results show that the introduction of superconducting power cables could achieve the improved use of regenerative brake, the loss reduction, the decreased number of substations, the reduced maintenance, etc.

  7. 78 FR 12967 - Broadcast Services; Children's Television; Cable Operators

    Science.gov (United States)

    2013-02-26

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 73 Broadcast Services; Children's Television; Cable Operators AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of effective date. SUMMARY: This document announces...

  8. Stability of Superconducting Rutherford Cables For accelerator magnets

    CERN Document Server

    Willering, GP; Verweij, A P

    2009-01-01

    The stability of superconducting magnets has a high priority for particle accelerators, since the operational time and operational collision energy depend strongly on it. Local heat dissipation due to beam loss and conductor movement is inevitable, causing local hot spots in the conductor, possibly leading to magnet quench. For stability against local and transient energy deposition, the cable is the most important unit to investigate. Most superconducting accelerator magnets are wound from Rutherford cables with a flat cable layout, consisting of twisted strands. The mechanisms of normal zone propagation in Rutherford cables have been described in detail with experimental and modeling data. The onset of a local normal zone forces current to redistribute in adjacent neighboring superconducting strands, reducing the longitudinal normal zone propagation. Transversal normal zone propagation in adjacent and crossing strands is caused by the redistribution of current and by heat exchange. The mechanism of normal z...

  9. Magnetic Flux Leakage Sensing-Based Steel Cable NDE Technique

    National Research Council Canada - National Science Library

    Park, Seunghee; Kim, Ju-Won; Lee, Changgil; Lee, Jong-Jae

    2014-01-01

    .... This inspection system measures magnetic flux to detect the local faults (LF) of steel cable. To verify the feasibility of the proposed damage detection technique, an 8-channel MFL sensor head prototype was designed and fabricated...

  10. ALOHA Cabled Observatory (ACO): Acoustic Doppler Current Profiler (ADCP): Temperature

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The University of Hawaii's ALOHA ("A Long-term Oligotrophic Habitat Assessment") Cabled Observatory (ACO) is located 100 km north of the island of Oahu, Hawaii (22...

  11. Applicability of cable theory to vascular conducted responses

    DEFF Research Database (Denmark)

    Hald, Bjørn Olav; Jensen, Lars Jørn; Sørensen, Preben Graae

    2012-01-01

    Conduction processes in the vasculature have traditionally been described using cable theory, i.e., locally induced signals decaying passively along the arteriolar wall. The decay is typically quantified using the steady-state length-constant, ¿, derived from cable theory. However......, the applicability of cable theory to blood vessels depends on assumptions that are not necessarily fulfilled in small arteries and arterioles. We have employed a morphologically and electrophysiologically detailed mathematical model of a rat mesenteric arteriole to investigate if the assumptions hold and whether...... ¿ adequately describes simulated conduction profiles. We find that several important cable theory assumptions are violated when applied to small blood vessels. However, the phenomenological use of a length-constant from a single exponential function is a good measure of conduction length. Hence, ¿ should...

  12. 78 FR 1823 - Cable Television Technical and Operational Requirements

    Science.gov (United States)

    2013-01-09

    ... From the Federal Register Online via the Government Publishing Office ] FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 79 Cable Television Technical and Operational Requirements AGENCY: Federal Communications Commission. ACTION: Proposed rule; extension of reply comment period. SUMMARY: In this document...

  13. Calculating Parameters for a ReBCO Cable Joint Terminal

    CERN Document Server

    Vipp, Venno

    2016-01-01

    The aim of this project was to evaluate the effects of temperature and length on the design of a joint for a 6-around 1 CORC based conductor and optimize the terminal geometry for a single strand cable.

  14. Loss and Inductance Investigation in Superconducting Cable Conductors

    DEFF Research Database (Denmark)

    Olsen, Søren Krüger; Tønnesen, Ole; Træholt, Chresten

    1999-01-01

    An important parameter in the design and optimization of a superconducting cable conductor is the control of the current distribution among single tapes and layers. This distribution is to a large degree determined by inductances, since the resistances are low. The self and mutual inductances...... of the layers are therefore studied theoretically. The current distribution between the superconducting layers is monitored as a function of transport current, and the results are compared with the expected current distribution given by our electrical circuit model.The AC-losses are measured as a function...... of transport current and current distribution.This presentation is based on a number of experiments performed on prototype superconducting cable conductors. The critical current (1uV/cm) of the conductor at 77K was 1590 A (cable #1) and 3240 A (cable #2) respectively.At an rms current of 2 kA (50 Hz) the AC...

  15. Development of YBCO HTS cable with low AC loss

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, M. [Energy Transmission Research Department Ecology and Energy Laboratory, Furukawa Electric Co., Ltd., 6, Yawata-Kaigandori, Ichihara, Chiba 290-8555 (Japan)], E-mail: m-yagi@ch.furukawa.co.jp; Mukoyama, S. [Energy Transmission Research Department Ecology and Energy Laboratory, Furukawa Electric Co., Ltd., 6, Yawata-Kaigandori, Ichihara, Chiba 290-8555 (Japan); Amemiya, N. [Yokohama National University, 79-5, Tokiwadai, Hodogaya, Yokohama 240-8501 (Japan); Nagaya, S.; Kashima, N. [Chubu Electric Power Co., Inc., 20-1, Kitasekiyama, Ohdaka-cho, Midori-ku, Nagoya 459-8522 (Japan); Shiohara, Y. [Superconductivity Research Laboratory, 1-10-13, Shinonome, Koto-ku, Tokyo 135-0062 (Japan)

    2008-09-15

    High temperature superconducting (HTS) cables using YBCO tapes are expected to be more economical because AC losses will be much smaller than conventional cables. To reduce AC loss, 10 mm wide YBCO tapes were divided into five strips using a YAG laser. Using narrower strips and optimizing the space between the strips were effective in reducing AC loss. A 1 m conductor was fabricated, and AC loss was 0.048 W/m at 1 kA and 50 Hz. Based on the successful AC loss reduction in the 1 m conductor, we will fabricate a 10 m HTS cable with a three-layer HTS conductor, electrical insulation, and a one-layer HTS shield and cupper protection layer for overcurrent. In addition, we have developed a prototype of the HTS cable joint that can withstand an overcurrent condition of 31.5 kA for 2 s.

  16. LOFT 3C cable tray and ladder seismic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mosby, W.R.

    1979-03-26

    The LOFT 3C cable tray and ladder were analyzed for LOCE and Safe Shutdown Earthquake (SSE) seismic loads by using equivalent static loads. Design changes were recommended to alleviate overstress conditions.

  17. ALOHA Cabled Observatory (ACO): Acoustic Doppler Current Profiler (ADCP): Velocity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The University of Hawaii's ALOHA ("A Long-term Oligotrophic Habitat Assessment") Cabled Observatory (ACO) is located 100 km north of the island of Oahu, Hawaii (22...

  18. Emerging Subsea Networks: SMART Cable Systems for Science and Society

    Science.gov (United States)

    Howe, B. M.; Butler, R.; Joint Task Force, U.

    2016-02-01

    The subsea telecommunications cable industry is approaching a prospective new era: deploying SMART subsea cable systems (SMART = Science Monitoring And Reliable Telecommunication). The current global, commercial cable infrastructure consists of 1 Gm of cable, being refreshed now and expanding in the future. The SMART concept is to add a small external sensor package along the cable system at its optical repeaters to transmit important real-time environmental data via a dedicated wavelength or overhead channel in the transmission system, avoiding any impact on the commercial traffic. These small, reliable, existing sensors would precisely measure temperature, pressure and three-axis acceleration across the world's ocean floor over an extended period of time, being deployed using standard cable-laying procedures on new or refurbished cables, but not requiring maintenance through the 2-3 decade life of the cable systems. The game-changing factor is the urgent international need for ocean environmental data related to mitigating climate and sea-level change and improving tsunami and slope failure hazard warnings. Societal costs incurred by these are reaching billions of dollars and hundreds of thousands of deaths. Pressures for new and urgent public policies are evident from the 5th IPCC Assessment, USA-China agreement on limiting greenhouse gas emissions, clear evidence for rapid global warming, 21st Session of the Conference of the Parties to the UNFCCC (December 2015, Paris), and the scale of the costs of inaction. To support revised public policies and actions, decision-makers, industry leaders, and the public are seeking key scientific data, which will necessitate new sources of funding. Hence, the emergence of new SMART cable systems offered by the subsea telecommunications industry will provide new market opportunities, engage additional non-traditional users, and make profound societal contributions. The Joint Task Force (JTF) on SMART Subsea Cable Systems

  19. An enhanced fire hazard assessment model and validation experiments for vertical cable trays

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lu [Sate Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027 (China); Huang, Xianjia, E-mail: huangxianjia@gziit.ac.cn [Joint Laboratory of Fire Safety in Nuclear Power Plants, Institute of Industry Technology Guangzhou & Chinese Academy of Sciences, Guangzhou 511458 (China); Bi, Kun; Liu, Xiaoshuang [China Nuclear Power Design Co., Ltd., Shenzhen 518045 (China)

    2016-05-15

    Highlights: • An enhanced model was developed for vertical cable fire hazard assessment in NPP. • The validated experiments on vertical cable tray fires were conducted. • The capability of the model for cable tray with different cable spacing were tested. - Abstract: The model, referred to as FLASH-CAT (Flame Spread over Horizontal Cable Trays), was developed to estimate the heat release rate for vertical cable tray fire. The focus of this work is to investigate the application of an enhanced model to the single vertical cable tray fires with different cable spacing. The experiments on vertical cable tray fires with three typical cable spacing were conducted. The histories of mass loss rate and flame length were recorded during the cable fire. From the experimental results, it is found that the space between cable lines intensifies the cable combustion and accelerates the flame spread. The predictions by the enhanced model show good agreements with the experimental data. At the same time, it is shown that the enhanced model is capable of predicting the different behaviors of cable fires with different cable spacing by adjusting the flame spread speed only.

  20. Electromagnetic analysis of current distribution in multistrand superconducting cables

    CERN Document Server

    Bottura, L; Negrini, F; Ribani, P L; Sandiumenge, F; Fontcuberta, J

    2000-01-01

    A new electromagnetic model for the simulation of transients in superconducting coils is presented. The model takes into account the non uniform current distribution in a multistrand cable. From Maxwell equations, a system of partial differential equations is obtained which describes the space and time dependence of current in the strands of the cable. The system is numerically solved by means of the finite element method. Comparison of numerical results with experimental ones is shown. (6 refs).

  1. Assessing Resilience in the Global Undersea Cable Infrastructure

    Science.gov (United States)

    2012-06-01

    Helena, Ascension , and Tristan da Cunha 6,724 143 Vanuatu 5,656 144 Virgin Islands 4,876 145 Papua New Guinea 4,847 146 Micronesia, Federated States... earthquakes , tsunamis, and undersea landslides occur less 9 frequently but typically affect multiple cables. Considering these natural and... earthquake along the southern coast of Taiwan triggered submarine landslides over large areas of the ocean floor and broke nine undersea cables in the

  2. CECOM Index of Technical Papers, International Wire and Cable Symposia,

    Science.gov (United States)

    1982-10-18

    PEIIFLUROALKOXY FLUOROCARBON RESIN PROPERTIES RELATING TO ELECTRICAL AN) ELECTRONIC APPLICATIONS BY: BJRO, Mole MC CANE, Del * ALLEN, 0.8.e StEED9 J.C...BIEBOHAVE. PIE . POLYFTHVLCNE. STALPETH. ALPETM) 2 A HIANLY EXPANDED POLYTVYLENE INSULATED CATV COAXIAL CARLE 51 TRUNK CABLE) CAIV SYSTEM OPERATION C CALE TEL...TUERHERD COMMUNICATION EAGLES 106 ARCO ALUMINUM STEEL CORmUNICATIDN PTPE 541 EpOS IN nESIGN AND INVTALLATION Or SBMARINE CONHMUNICATION CABLE EXPERIENEE

  3. Usage of Cable Bolts for Gateroad Maintenance in Soft Rocks

    Directory of Open Access Journals (Sweden)

    Iurii Khalymendyk

    2014-01-01

    Originality/value: 1. There are no regulations and state standards in regard to cable bolt installation parameters in the mines of Ukraine, consequently the usage of cable bolts for gateroad maintenance required preliminary testing under geological conditions at the Western Donbass mines with soft enclosing rocks. 2. Combining levelling with observations using extensometers allowed for the detection of the rock layers' uniform sagging zone in the roof of the gateroad.

  4. Thermoplastic high performance cable insulation systems for flexible system operation

    OpenAIRE

    Vaughan, A.S.; Green, C.D.; Hosier, I.L.; Stevens, G.C.; Pye, A.; Thomas, J.L.; Sutton, S.J.; Guessens, T.

    2015-01-01

    Crosslinked polyethylene (XLPE) has been the cable insulation material of choice in many different transmission and distribution applications for many years and, while this material has many desirable characteristics, its thermo-mechanical properties have consequences for both continuous and emergency cable ratings which, in turn, have implications for system operational flexibility. In this paper, we describe the principles and two embodiments through which new thermoplastic insulation syste...

  5. Design and Installation of Nearshore Ocean Cable Protection Systems,

    Science.gov (United States)

    1979-11-01

    SUPPLEMENTARY NOTATION 17. COSATI CODES 18. SUBJECT TERMS (Continue on reverse if nec.) FIELD GROUP SUB-GROUP Design. Cable installation retrieval & repair...Cable protection 19. ABSTRACT (Continue on reverse if necessary & identify by block number) The U.S. Navy currentlyhas a requirment to install and...2-26 Data Requirements .. ....... ....... .. 2-26 Reporting .. .. ........ ....... .... 2-26 2.4.2 Logistcs

  6. High temperature superconductor cable concepts for fusion magnets

    CERN Document Server

    AUTHOR|(CDS)2078397

    2013-01-01

    Three concepts of high temperature superconductor cables carrying kA currents (RACC, CORC and TSTC) are investigated, optimized and evaluated in the scope of their applicability as conductor in fusion magnets. The magnetic field and temperature dependence of the cables is measured; the thermal expansion and conductivity of structure, insulation and filling materials are investigated. High temperature superconductor winding packs for fusion magnets are calculated and compared with corresponding low temperature superconductor cases.

  7. Break-even zones for cable yarding by log size

    Science.gov (United States)

    Chris B. LeDoux

    1984-01-01

    The use of cable logging to extract small pieces of residue wood may result in low rates of production and a high cost per unit of wood produced. However, the logging manager can improve yarding productivity and break-even in cable residue removal operations by using the proper planning techniques. In this study, break-even zones for specific young-growth stands were...

  8. A New Cable-Pulley Algorithm in RFEM

    Directory of Open Access Journals (Sweden)

    Štekbauer Hynek

    2016-11-01

    Full Text Available The cable-pulley system is widely used for its advantages. In this paper, application of a new algorithm for the calculation of cables on pulleys is presented. Unlike other algorithms, this algorithm enables to take the magnitude of the radius of each pulley into account. This new algorithm is implemented in the RFEM program because of its higher accuracy and efficiency. Comparison of the commonly used algorithm, which ignores pulley radius, and the new algorithm is presented.

  9. Development of Vertical Cable Seismic System

    Science.gov (United States)

    Asakawa, E.; Murakami, F.; Sekino, Y.; Okamoto, T.; Ishikawa, K.; Tsukahara, H.; Shimura, T.

    2011-12-01

    In 2009, Ministry of Education, Culture, Sports, Science and Technology(MEXT) started the survey system development for Hydrothermal deposit. We proposed the Vertical Cable Seismic (VCS), the reflection seismic survey with vertical cable above seabottom. VCS has the following advantages for hydrothermal deposit survey. (1) VCS is an efficient high-resolution 3D seismic survey in limited area. (2) It achieves high-resolution image because the sensors are closely located to the target. (3) It avoids the coupling problems between sensor and seabottom that cause serious damage of seismic data quality. (4) Because of autonomous recording system on sea floor, various types of marine source are applicable with VCS such as sea-surface source (GI gun etc.) , deep-towed or ocean bottom source. Our first experiment of 2D/3D VCS surveys has been carried out in Lake Biwa, JAPAN, in November 2009. The 2D VCS data processing follows the walk-away VSP, including wave field separation and depth migration. Seismic Interferometry technique is also applied. The results give much clearer image than the conventional surface seismic. Prestack depth migration is applied to 3D data to obtain good quality 3D depth volume. Seismic Interferometry technique is applied to obtain the high resolution image in the very shallow zone. Based on the feasibility study, we have developed the autonomous recording VCS system and carried out the trial experiment in actual ocean at the water depth of about 400m to establish the procedures of deployment/recovery and to examine the VC position or fluctuation at seabottom. The result shows that the VC position is estimated with sufficient accuracy and very little fluctuation is observed. Institute of Industrial Science, the University of Tokyo took the research cruise NT11-02 on JAMSTEC R/V Natsushima in February, 2011. In the cruise NT11-02, JGI carried out the second VCS survey using the autonomous VCS recording system with the deep towed source provided by

  10. Design Improvements to Cables and Connectors in the MAJORANA DEMONSTRATOR

    Science.gov (United States)

    Reine, Anna; Haufe, Christopher; Majorana Collaboration

    2017-09-01

    The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The DEMONSTRATOR uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at each detector's point contact. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the MAJORANA DEMONSTRATOR are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors, the initial performance of our improved designs, and applications for development of LEGEND, a next-generation tonne-scale 76Ge experiment. This material is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, the Particle Astrophysics and Nuclear Physics Programs of the National Science Foundation, and the Sanford Underground Research Facility.

  11. Over-current characteristics of YBCO superconducting cable

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X., E-mail: wan-x-don@waseda.j [Waseda University, Department of Electrical Engineering and Bioscience, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Ueda, H.; Ishiyama, A. [Waseda University, Department of Electrical Engineering and Bioscience, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Yagi, M.; Mukoyama, S. [Furukawa Electric Co., Ltd., Ecology and Energy Laboratory, Ichihara 290-8555 (Japan); Kashima, N.; Nagaya, S. [Chubu Electric Power Co., Inc., Nagoya (Japan); Shiohara, Y. [International Superconductivity Technology Center, Superconductivity Research Laboratory, 1-10-13 Shinonome, Koto-ku, Tokyo 135-0062 (Japan)

    2009-10-15

    To achieve large current capacity and high mechanical flexibility, YBa{sub 2}Cu{sub 3}O{sub 7} (YBCO) superconducting cables consist of a number of YBCO coated conductors that are assembled and wound spirally on a Cu former. In practical applications, superconducting cables are vulnerable to short-circuit fault currents that are 10-30 times greater than the operating current. Therefore, in order to ensure the stability of YBCO superconducting cables in such a situation and to protect them from the fault currents, it is important to investigate the redistribution of the transport current and electromagnetic coupling between the conductor layer, shield layer, and Cu former. In this study, we carried out experiments on a 10-m-long YBCO model cable, which was manufactured by Furukawa Electric. An over-current with a peak of 31.8 kA{sub rms} and a duration of 2.02 s was applied to the model cable. We performed numerical simulations using a novel computer program developed using the 3D finite element method to elucidate the electromagnetic and thermal behavior of the YBCO model cable in the presence of an over-current.

  12. Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments

    Science.gov (United States)

    Ramesham, Rajeshuni; Lindensmith, Christian A.; Roberts, William T.; Rainen, Richard A.

    2011-01-01

    Means have been developed for enabling fiber optic cables of the Laser Induced Breakdown Spectrometer instrument to survive ground operations plus the nominal 670 Martian conditions that include Martian summer and winter seasons. The purpose of this development was to validate the use of the rover external fiber optic cabling of ChemCam for space applications under the extreme thermal environments to be encountered during the Mars Science Laboratory (MSL) mission. Flight-representative fiber optic cables were subjected to extreme temperature thermal cycling of the same diurnal depth (or delta T) as expected in flight, but for three times the expected number of in-flight thermal cycles. The survivability of fiber optic cables was tested for 600 cumulative thermal cycles from -130 to +15 C to cover the winter season, and another 1,410 cumulative cycles from -105 to +40 C to cover the summer season. This test satisfies the required 3 times the design margin that is a total of 2,010 thermal cycles (670 x 3). This development test included functional optical transmission tests during the course of the test. Transmission of the fiber optic cables was performed prior to and after 1,288 thermal cycles and 2,010 thermal cycles. No significant changes in transmission were observed on either of the two representative fiber cables subject through the 3X MSL mission life that is 2,010 thermal cycles.

  13. Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-30

    This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are

  14. Estimation of cables’ tension of cable-stayed footbridge using measured natural frequencies

    Directory of Open Access Journals (Sweden)

    Jakiel Przemysław

    2017-01-01

    Full Text Available This paper presents analysis of cables’ tension of steel cable-stayed footbridge using their field-test natural frequencies. A vibration method is usually used for the measured cable tension during the construction of cable systems stiffened with inclined cables. Practical formulas for the vibration method applied herein, mainly based on cable-sag and vertical angle effects (a survey measurement, have been verified on the one-tower steel cable-stayed bridge. The bridge is situated in Sieradz (Poland and it was the structure with the longest span concerning all the cable-stayed bridges in Poland until 1999. The obtained cable axial forces for estimated natural frequencies of low- and high-order modes are verified using FEM models. The final conclusions drawn on the basis of conducted studies can be useful for technical diagnosis, monitoring programs and repair works of similar class of cable-stayed bridges.

  15. Damping Estimation from Free Decay Responses of Cables with MR Dampers

    Directory of Open Access Journals (Sweden)

    Felix Weber

    2015-01-01

    Full Text Available This paper discusses the damping measurements on cables with real-time controlled MR dampers that were performed on a laboratory scale single strand cable and on cables of the Sutong Bridge, China. The control approach aims at producing amplitude and frequency independent cable damping which is confirmed by the tests. The experimentally obtained cable damping in comparison to the theoretical value due to optimal linear viscous damping reveals that support conditions of the cable anchors, force tracking errors in the actual MR damper force, energy spillover to higher modes, and excitation and sensor cables hanging on the stay cable must be taken into consideration for the interpretation of the identified cable damping values.

  16. Damping Estimation from Free Decay Responses of Cables with MR Dampers

    Science.gov (United States)

    Weber, Felix; Distl, Hans

    2015-01-01

    This paper discusses the damping measurements on cables with real-time controlled MR dampers that were performed on a laboratory scale single strand cable and on cables of the Sutong Bridge, China. The control approach aims at producing amplitude and frequency independent cable damping which is confirmed by the tests. The experimentally obtained cable damping in comparison to the theoretical value due to optimal linear viscous damping reveals that support conditions of the cable anchors, force tracking errors in the actual MR damper force, energy spillover to higher modes, and excitation and sensor cables hanging on the stay cable must be taken into consideration for the interpretation of the identified cable damping values. PMID:26167537

  17. Design, analysis and control of cable-suspended parallel robots and its applications

    CERN Document Server

    Zi, Bin

    2017-01-01

    This book provides an essential overview of the authors’ work in the field of cable-suspended parallel robots, focusing on innovative design, mechanics, control, development and applications. It presents and analyzes several typical mechanical architectures of cable-suspended parallel robots in practical applications, including the feed cable-suspended structure for super antennae, hybrid-driven-based cable-suspended parallel robots, and cooperative cable parallel manipulators for multiple mobile cranes. It also addresses the fundamental mechanics of cable-suspended parallel robots on the basis of their typical applications, including the kinematics, dynamics and trajectory tracking control of the feed cable-suspended structure for super antennae. In addition it proposes a novel hybrid-driven-based cable-suspended parallel robot that uses integrated mechanism design methods to improve the performance of traditional cable-suspended parallel robots. A comparative study on error and performance indices of hybr...

  18. Ocean Observing using SMART subsea telecommunications cable systems

    Science.gov (United States)

    Howe, B. M.

    2015-12-01

    Planning is underway to integrate ocean sensors into SMART subsea cable systems providing basin and ultimately global array coverage within the next decades (SMART: Scientific Monitoring And Reliable Telecommunications). SMART cables will: contribute to the understanding of ocean dynamics and climate; improve knowledge of earthquakes and forecasting of tsunamis; and complement and enhance existing satellite and in-situ observing systems. SMART cables will be a first order addition to the ocean observing system, with unique contributions, strengthening and complementing satellite and in situ systems. Cables spanning the ocean basins with repeaters every ~50 km will host sensors/mini-observatories, providing power and real-time communications. The current global infrastructure of commercial submarine telecommunications cable systems consists of 1 Gm of cable with ~20,000 repeaters (to boost optical signals); the overall system is refreshed and expanded on time scales of 10 - 20 years and individual systems have lifetimes in excess of 25 years. Initial instrumentation of the cables with bottom temperature, pressure and acceleration sensors will provide unique information for monitoring and studying climate change and for improved tsunami and earthquake warning. These systems will be a new highly reliable, long-lived component of the ocean observing system, complementing satellite, float and other in situ platforms and measurements. Several UN agencies, the International Telecommunication Union, the World Meteorological Organization, and the UNESCO Intergovernmental Oceanographic Commission have formed a Joint Task Force to move this concept to fruition (ITU/WMO/IOC JTF; http://www.itu.int/en/ITU-T/climatechange/task-force-sc). A review of the overall planning effort and two NASA-funded workshops focusing on the ocean circulation and climate is presented. [Funding provided by NASA.

  19. Estimation of Cable Forces of a Guyed Mast from Dynamic Measurements

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Hansen, Lars Pilegaard

    This paper presents how the tension forces in the cables of a 200 m. high guyed mast have been estimated from natural frequencies obtained from acceleration measurements.The mast is guyed at five levels with three guys at 120 degree intervals at each level. The accelerations in three directions...... were measured in five cables. The relationship between frequencies and cable forces have been establish assuming the cables to behave in linear manner. The results show that estimated cables forces correspond very well to the expected. The results obtained showed that it was possible to obtain reliable...... estimates for cables forces based on measured natural frequencies....

  20. Switching Overvoltages in 60 kV reactor compensated cable grid due to resonance after disconnection

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Baldursson, Haukur; Oumarou, Abdoul M.

    2008-01-01

    power could be directly connected to long cables. Switching both cable and reactor together will cause resonance to occur between the cable capacitance and the inductance of the cable during last end disconnection. Similar type of resonance condition is known to have caused switching overvoltages......Some electrical distribution companies are nowadays replacing overhead lines with underground cables. These changes from overhead to underground cable provoke an increased reactive power production in the grid. To save circuit breakers the reactors needed for compensating this excessive reactive...

  1. ALOHA Cabled Observatory: Continuing lessons and results

    Science.gov (United States)

    Howe, B. M.; Lukas, R.

    2012-12-01

    Since June 2011, the ALOHA Cabled Observatory (ACO) is providing 1 kW power, 100 Mbs network communications and PPS timing to a seafloor node and instruments at 4728 m water depth 100 km north of Oahu. Station ALOHA is the field site of the Hawaii Ocean Time-series (HOT) program that has investigated physical and biogeochemical variability of the water column near-monthly since 1988. The abyssal near bottom acoustic Doppler profiler data are showing stronger than expected internal tide flows and turbulence 20-80 m above bottom. In this oligotrophic environment, the video camera has detected significant biological activity. Acoustic data collected on two hydrophones clearly show very high call density of baleen whales during September-May and sperm whale choruses spread throughout the year. Recent Navy exercises provided examples of anthropogenic sounds. We are also monitoring in real time an acoustic "heartbeat" signal from the nearby HOT Profiler mooring (M. Alford et al.). ACO operation over the last year continues to provide valuable lessons. Several failures occurred at or during deployment, including two ground faults that have isolated two CTDs, a fluorometer, and an acoustic modem from the system. Two independent LED light systems failed after 4 and 6 weeks. Most recently, the pressure sensor has failed perhaps due to loss of vacuum in the quartz crystal chamber. The one remaining conductivity/temperature sensor is episodically, but strongly, affected by thermal plume signatures from the nearby power supply. Understanding the reasons for these failures and limitations will be necessary to improve the methodologies for sustained long-term abyssal measurements. This will be well worth the effort, as suggested by the surprisingly rich video, ADCP, and acoustic data sets.

  2. Los prensacables como sistema de amarre de cables

    Directory of Open Access Journals (Sweden)

    Ana Patricia Garzón Fuentes

    2011-01-01

    Full Text Available En Colombia, uno de los elementos más comúnmente usados en el amarre y sujeción de cables de acero dentro de sus diferentes aplicaciones, son los prensacables o grapas, los cuales se conocen más corrientemente como perros. A pesar de ser tan conocidos y utilizados, es poca la información técnica que se tiene acerca de estos elementos, debido a que no ha existido la suficiente investigación pertinente. Esto hace que exista una gran incertidumbre respecto a la colocación, montaje, resistencia y comportamiento de los prensacables. En recientes ensayos se ha demostrado que los prensacables usados para asegurar los cables de acero en diferentes tipos de estructuras se deslizan a una carga menor que la carga de rotura de los cables que amarran. Actualmente, los diseños se realizan según la carga de rotura de los cables, por lo cual es importante estimar la carga de desIizamiento de los prensacables para que los diseños sean adecuados. Preocupada por esta situación, la Unidad de Estructuras de la Universidad Nacional de Colombia realizó un estudio tendiente a minimizar la incertidumbre existente en el empleo de esos elementos de sujeción. Para tal erecto, se efectuaren una serie de ensayos de tensión sobre probetas de cable de 1/2" y 3/4" de diámetro, amarradas con diferentes números de prensa cables de diámetros respectivos. Se utilizaron prensacables de tres marcas, dos nacionales y una importada. Con base en estos ensayos se encontré que el torque aplicado ala tuerca del prensacable cuando se realiza el montaje de éste sobre un cable, es el parámetro fundamental para un adecuado comportamiento del mismo. Además, debe colocarse una cantidad mínima de prensacables del mismo diámetro del cable que se va a amarrar para que haya una adecuada sujeción. Otro parámetro que se encontró importante fue la orientación de los prensacables en el montaje respecto a la punta muerta (lado corto del cable.

  3. Validation of shielding effectiveness of cables with pigtails

    Science.gov (United States)

    Blocher, Timothy W.

    1990-03-01

    This report focuses on the validation of experimental data used to develop the field-to-wire coupling algorithm in the Intrasystem Electromagnetic Compatibility Analysis Program (IEMCAP). IEMCAP is a computer code used to assess the electromagnetic compatibility (EMC) of Air Force systems. The experimental data of interest was obtained by measuring, in a mode tuned reverberation chamber (MTRC), the shielding effectiveness (SE) of coaxial cables terminated in pigtails. The results of these measurements indicate that a coaxial cable terminated in pigtail has no shielding from electromagnetic interference (EMI). When repeating these measurements, it was found that coaxial cables terminated in pigtails can have a degree of SE. Due to the opposing results, the various characteristics of pigtails, such as length and construction, are investigated to determine which pigtail attributes critically reduce the SE of coaxial cables. From this investigation, the parameters that critically reduce the SE of coaxial cables are identified. Recommendations are then made regarding the field-to-wire coupling algorithm in IEMCAP and regarding follow-up investigations.

  4. Seismic response of cable stayed bridges under multi support excitation

    Directory of Open Access Journals (Sweden)

    Mahmoud Reza ُُShiravand

    2017-07-01

    Full Text Available In this Study, the seismic response of cable stayed bridges have been evaluated under multi-support excitations. There are three sources that cause the earthquake wave characteristics change during its propagation path. Local site effect, loss of coherency and wave passage effect are three sources of spatial variation of seismic ground motions. In long span structures, such as cable supported bridges, this phenomenon is more evident and traditional analyzing (uniform excitation may not be valid and be conservative. Thus, it is necessary to investigate the response of cable stayed bridges under non-uniform excitations. For this purpose, the non-uniform time histories were artificially generated using Kriging method based on a set of known time history in the west support of bridge. Nonlinear time history analysis was performed and cables axial force, deck moment, pylons moment and finally drift ratio of bridge have been examined in order to investigate how non-uniform excitation change the seismic response of bridge compared with uniform excitations. Results show non-uniform excitation in some bridge components increase responses and decreases in the others. In non-uniform excitation, although total time history energy is lesser than uniform excitation, it can significantly change the distribution of the forces and makes differential displacement between cables supports and increase the possibility of failure.

  5. Kinematic and Dynamic Analysis of a Cable-Climbing Robot

    Directory of Open Access Journals (Sweden)

    Xu Fengyu

    2015-07-01

    Full Text Available To inspect broken cables or a cracked protective layer on cable-stayed bridges, a cable-climbing robot has been proposed and designed. In this paper, the complex 3D obstacles that may be encountered on cables are theoretically described, in order to investigate the obstacle-climbing capability of the cable-climbing robot. A climbing model is then proposed and used to design the robot. In the climbing model, two driven wheels are independently supported with a spring. Kinematics and dynamics models are further derived for the obstacle-climbing capabilities of the driving and driven wheels of the robot. In addition, the robot's obstacle-climbing tracks and its obstacle-climbing performance are simulated. Payload and obstacle-climbing experiments were conducted on the climbing robot in the laboratory. Based on the results of the simulation and the experiments, we obtained the variation of the driving torque in obstacle climbing. The contribution of this paper is intended to provide a basis for the precise motion control of the robot.

  6. Touch DNA-The prospect of DNA profiles from cables.

    Science.gov (United States)

    Lim, Sharon; Subhani, Zuhaib; Daniel, Barbara; Frascione, Nunzianda

    2016-05-01

    Metal theft in the railroad industry poses significant challenges to transport investigators. Cable sheaths left behind at crime scenes, if appropriately analysed, could provide valuable evidence in a forensic investigation, but attempts at recovering DNA are not routinely made. Experiments were set up to ascertain the success in DNA recovery from the surface of cable sheaths after deposition of (a) sweat, (b) extracted DNA and (c) fingermarks. Since investigators try to collect fingermarks and often treat the cables with cyanoacrylate fuming (CNA fuming) or wet powder suspensions (WPS) to enhance the marks this study investigated the recovery of DNA from fingermarks pre- and post-enhancement. The double-swab technique and mini-taping were compared as options to recover DNA from the cable sheaths. Results demonstrate that generally, there is no significant difference between using swabs or mini-tapes to recover the DNA from the non-porous cables (p>0.05). It was also illustrated that CNA fuming performed better than WPS in terms of subsequent recovery and profiling of DNA. CNA fuming resulted in an average increase in DNA recovered via swabbing and taping (more than 4× and 8×, respectively), as compared to no treatment, with 50% of the DNA recovered after CNA fuming generating full DNA profiles. Copyright © 2016 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Dynamic tensile test of single PET textile cables

    Directory of Open Access Journals (Sweden)

    Pasco F.

    2012-08-01

    Full Text Available The tyres conception involves for certain applications, the use of textile cables as reinforcement. During its use, the tyre undergoes temperatures variations and dynamic loading rates. The consideration of these conditions during the numeric simulations requires the knowledge of the sensitivity of the mechanical behaviour to loading rate and temperature. In this paper, we developed an experimental methodology for testing textile cable up to high strain rate. The main difficulty of testing cables is the optimization of cable fixing on the machine. For that purpose, we adapted the solution of fixing by progressive binding already used in quasi-static, while taking into account constraints inherent to high strain tests. Firstly, the mass of grips was decreased in order to get force signal less sensitive to grips inertia. The method was developed on a high speed hydraulic machine equipped with a thermal enclosure. The investigated temperatures and strain rates range from room temperature to 373 ∘K (100 ∘C and from 0,01 to 100/s, respectively. In addition, the hydraulic machine was equipped with a high speed video camera. The obtained images were analysed by a tracking technique to measure the average strain in the cable (from 50 to 20000 f/s.

  8. Some considerations on special spacers with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges; Heiretsu cable yo gensui kino tsuki supesa no gensui fuka tokusei ni kansuru 2,3 no kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M. [Kinki Univ., Higashi-Osaka, Osaka (Japan). Faculty of Science and Technology] Setouchi, H. [Kawada Industries Inc., Osaka (Japan)

    1998-03-20

    Cable vibration called wake galloping appears on cable-stayed bridges with parallel arranged cables and its suppression is an important problem. Various methods have been proposed for spacers with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges. But, comparison of damping performances of various methods have not been discussed sufficiently. This paper deals with a type in which dampers are equipped on the midway of the tandem cables through the spacer jig and a type in which dampers are equipped on each surface of the tandem cables to generate shear deformation between them and circular spacer jig moiety and complex eigenvalue analyses are carried out on the two types with changing center spacing and diameters of the cables. The results clarify the relation between the structural damping characteristics and the cable spacing and the effect of torsional rigidity of the cables and also clarify of damping characteristics of the two types. 16 refs., 14 figs., 4 tabs.

  9. Development of (RE)BCO cables for HTS power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Mukoyama, S., E-mail: mukoyama@ch.furukawa.co.j [Furukawa Electric Co. Ltd., Ichihara 290-8555 (Japan); Yagi, M. [Furukawa Electric Co. Ltd., Ichihara 290-8555 (Japan); Masuda, T. [Sumitomo Electric Industries, Ltd., Osaka 554-0024 (Japan); Amemiya, N. [Kyoto University, Kyoto 615-8510 (Japan); Ishiyama, A. [Waseda University, Tokyo 169-8555 (Japan); Kashima, N.; Nagaya, S. [Chubu Electric Power Co. Inc., Nagoya 459-8522 (Japan); Aoki, Y. [Showa Cable System Co. Ltd., Sagamihara 229-1133 (Japan); Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y. [Superconductivity Research Laboratory, Tokyo 135-0062 (Japan)

    2009-10-15

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I{sub c} and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  10. Optimum design of concrete cable-stayed bridges

    Science.gov (United States)

    Martins, Alberto M. B.; Simões, Luís M. C.; Negrão, João H. J. O.

    2016-05-01

    The design of cable-stayed bridges involves a significant number of design variables and design objectives. The concrete cable-stayed bridge optimization is formulated here as a multi-objective optimization problem with objectives of minimum cost, minimum deflections and minimum stresses. A numerical method is developed to obtain the optimum design of such structures. This numerical method includes: structural analysis, sensitivity analysis and optimization. The structural analysis accounts for all the relevant effects (concrete time-dependent effects, construction stages and geometrical nonlinear effects). The structural response to changes in the design variables is achieved by a discrete direct sensitivity analysis procedure, and an entropy-based approach was used for structural optimization. The features and applicability of the proposed method are demonstrated by numerical examples concerning the optimization of a real-sized concrete cable-stayed bridge.

  11. Optimizing wind farm cable routing considering power losses

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    2017-01-01

    that must be spent immediately in cable and installation costs, and the future reduced revenues due to power losses. The latter goal has not been addressed in previous work. We present a Mixed-Integer Linear Programming approach to optimize the routing using both exact and math-heuristic methods...... it is important to optimize o shore inter-array cable routing. The routing should connect all turbines to one (or more) o shore sub-station(s) while respecting cable capacities, no-cross restrictions, connection-limits at the substation, and obstacles at the site. The objective is to minimize both the capital....... In the power losses computation, wind scenarios are handled eciently as part of the preprocessing, resulting in a MIP model of only slightly larger size. A library of real-life instances is introduced and made publicly available for benchmarking. Computational results on this testbed show the viability of our...

  12. Optimizing wind farm cable routing considering power losses

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    that must be spent immediately in cable and installation costs, and the future reduced revenues due to power losses. The latter goal has not been addressed in previous work. We present a Mixed-Integer Linear Programming approach to optimize the routing using both exact and math-heuristic methods...... it is important to optimize o shore inter-array cable routing. The routing should connect all turbines to one (or more) o shore sub-station(s) while respecting cable capacities, no-cross restrictions, connection-limits at the substation, and obstacles at the site. The objective is to minimize both the capital....... In the power losses computation, wind scenarios are handled eciently as part of the preprocessing, resulting in a MIP model of only slightly larger size. A library of real-life instances is introduced and made publicly available for benchmarking. Computational results on this testbed show the viability of our...

  13. Laplace Synthesis Validation through Measurements on Underground Transmission Cables

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-10-01

    Full Text Available Underground cable electrical parameters ZY as well as their modal propagation characteristics are highly frequency dependent which in certain cases turns its analysis difficult. To perform electromagnetic transient studies of cables the calculation of electrical parameters is essential to obtain the waves propagation solution through the multiconductor system. At the same time this requires to solve the inverse Laplace transform on a numerical form. Although the analytic Laplace transform has an indisputable accuracy, the application of its numerical version up-to-date has not been completely accepted. A complete methodology is developed in this work to guide analyst engineers or graduate students in the calculation of electromagnetic transients of underground cable systems. Finally, to help the validation of the numerical inverse Laplace transform a scaled prototype experiment is performed in the laboratory in which a transient step-response at the remote end of an energized conductor is measured.

  14. Design of a Micro Cable Tunnel Inspection Robot

    Science.gov (United States)

    Song, Wei; Liu, Lei; Zhou, Xiaolong; Wang, Chengjiang

    2016-11-01

    As the ventilation system in cable tunnel is not perfect and the environment is closed, it is easy to accumulate toxic and harmful gas. It is a serious threat to the life safety of inspection staff. Therefore, a micro cable tunnel inspection robot is designed. The whole design plan mainly includes two parts: mechanical structure design and control system design. According to the functional requirements of the tunnel inspection robot, a wheel arm structure with crawler type is proposed. Some sensors are used to collect temperature, gas and image and transmit the information to the host computer in real time. The result shows the robot with crawler wheel arm structure has the advantages of small volume, quick action and high performance-price ratio. Besides, it has high obstacle crossing and avoidance ability and can adapt to a variety of complex cable tunnel environment.

  15. Vibrations of a Shallow Cable with a Viscous Damper

    DEFF Research Database (Denmark)

    Krenk, Steen; Nielsen, Søren R. K.

    2002-01-01

    The optimal tuning and effect in terms of modal damping of a viscous damper mounted near the end of a shallow cable are investigated. The damping properties of free vibrations are extracted from the complex wavenumber. The full solution for the lower modes is evaluated numerically, and an explicit...... and rather accurate analytical approximation is obtained, generalizing recent results for a taut cable. It is found that the effect of the damper on the nearly antisymmetric modes is independent of the sag and the stiffness parameter. In contrast, the nearly symmetric modes develop regions of reduced motion...... near the ends, with increasing cable stiffness, and this reduces the effect of the viscous damper. Explicit results are obtained for the modal damping radio and for optimal tuning of the damper....

  16. Approximate Series Solutions for Nonlinear Free Vibration of Suspended Cables

    Directory of Open Access Journals (Sweden)

    Yaobing Zhao

    2014-01-01

    Full Text Available This paper presents approximate series solutions for nonlinear free vibration of suspended cables via the Lindstedt-Poincare method and homotopy analysis method, respectively. Firstly, taking into account the geometric nonlinearity of the suspended cable as well as the quasi-static assumption, a mathematical model is presented. Secondly, two analytical methods are introduced to obtain the approximate series solutions in the case of nonlinear free vibration. Moreover, small and large sag-to-span ratios and initial conditions are chosen to study the nonlinear dynamic responses by these two analytical methods. The numerical results indicate that frequency amplitude relationships obtained with different analytical approaches exhibit some quantitative and qualitative differences in the cases of motions, mode shapes, and particular sag-to-span ratios. Finally, a detailed comparison of the differences in the displacement fields and cable axial total tensions is made.

  17. Effects of ice accretion on the aerodynamics of bridge cables

    DEFF Research Database (Denmark)

    Demartino, C.; Koss, Holger; Georgakis, Christos T.

    2015-01-01

    Undesirable wind induced vibrations of bridge cables can occur when atmospheric conditions are such to generate ice accretion. This paper contains the results of an extensive investigation of the effects of ice accretion due to in-cloud icing, on the aerodynamic characteristics of bridge hangers...... and stay cables. The aim of this paper is twofold; first, it was investigated the ice accretion process and the final shape of the ice accreted; then the aerodynamics of the ice accreted bridge cables was characterized, and related to the ice shape. Different climatic conditions, i.e. combinations...... of the ice accretions is given in the paper. Only for the bridge hanger case, a short description of the evolution of the ice accretions is given. The aerodynamic force coefficients were then measured with varying yaw angle, angle of attack and wind speed, and are presented and discussed in the paper...

  18. Median guard cable performance in relation with median slope on Interstate 70.

    Science.gov (United States)

    2010-01-01

    The current study was conducted along the entire Interstate 70 to investigate how median slopes influence guard cable : effectiveness. It was found out that the success rates for guard cables installed on both steeper and flatter slopes are high. Med...

  19. DC performance and AC loss of cable-in-conduit conductors for International Thermonuclear Experimental Reactor

    National Research Council Canada - National Science Library

    Zhou, Wei; Fang, Xin-Yu; Fang, Jin; Liu, Bo

    2016-01-01

    ...) cable-in-conduit conductors(CICCs);however,the calculation of AC loss of ITER CICCs is a cumbersome task due to the complicated geometry of the multistage cables and the extreme operating conditions...

  20. Switching Overvoltages in 60 kV reactor compensated cable grid due to resonance after disconnection

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Baldursson, Haukur; Oumarou, Abdoul M.

    2008-01-01

    Some electrical distribution companies are nowadays replacing overhead lines with underground cables. These changes from overhead to underground cable provoke an increased reactive power production in the grid. To save circuit breakers the reactors needed for compensating this excessive reactive...

  1. Development of Vertical Cable Seismic System (3)

    Science.gov (United States)

    Asakawa, E.; Murakami, F.; Tsukahara, H.; Mizohata, S.; Ishikawa, K.

    2013-12-01

    The VCS (Vertical Cable Seismic) is one of the reflection seismic methods. It uses hydrophone arrays vertically moored from the seafloor to record acoustic waves generated by surface, deep-towed or ocean bottom sources. Analyzing the reflections from the sub-seabed, we could look into the subsurface structure. Because VCS is an efficient high-resolution 3D seismic survey method for a spatially-bounded area, we proposed the method for the hydrothermal deposit survey tool development program that the Ministry of Education, Culture, Sports, Science and Technology (MEXT) started in 2009. We are now developing a VCS system, including not only data acquisition hardware but data processing and analysis technique. We carried out several VCS surveys combining with surface towed source, deep towed source and ocean bottom source. The water depths of the survey are from 100m up to 2100m. The target of the survey includes not only hydrothermal deposit but oil and gas exploration. Through these experiments, our VCS data acquisition system has been completed. But the data processing techniques are still on the way. One of the most critical issues is the positioning in the water. The uncertainty in the positions of the source and of the hydrophones in water degraded the quality of subsurface image. GPS navigation system are available on sea surface, but in case of deep-towed source or ocean bottom source, the accuracy of shot position with SSBL/USBL is not sufficient for the very high-resolution imaging. We have developed another approach to determine the positions in water using the travel time data from the source to VCS hydrophones. In the data acquisition stage, we estimate the position of VCS location with slant ranging method from the sea surface. The deep-towed source or ocean bottom source is estimated by SSBL/USBL. The water velocity profile is measured by XCTD. After the data acquisition, we pick the first break times of the VCS recorded data. The estimated positions of

  2. Optimizing wind farm cable routing considering power losses

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    2017-01-01

    Wind energy is the fastest growing source of renewable energy, but as wind farms are getting larger and more remotely located, installation and infrastructure costs are rising. It is estimated that the expenses for electrical infrastructure account for 15-30% of the overall initial costs, hence...... it is important to optimize o shore inter-array cable routing. The routing should connect all turbines to one (or more) o shore sub-station(s) while respecting cable capacities, no-cross restrictions, connection-limits at the substation, and obstacles at the site. The objective is to minimize both the capital...

  3. Improved Method for PD-Quantification in Power Cables

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Villefrance, Rasmus; Henriksen, Mogens

    1999-01-01

    n this paper, a method is described for improved quantification of partial discharges(PD) in power cables. The method is suitable for PD-detection and location systems in the MHz-range, where pulse attenuation and distortion along the cable cannot be neglected. The system transfer function...... was calculated and measured in order to form basis for magnitude calculation after each measurements. --- Limitations and capabilities of the method will be discussed and related to relevant field applications of high frequent PD-measurements. --- Methods for increased signal/noise ratio are easily implemented...

  4. ALOHA Cabled Observatory: On-going results and new instruments

    Science.gov (United States)

    Howe, B. M.; Lukas, R.

    2013-12-01

    Since June 2011, the ALOHA Cabled Observatory (ACO) has been collecting abyssal oceanographic data. The ACO is at Station ALOHA 100 km north of Oahu, the field site of the Hawaii Ocean Time-series (HOT) program that has collected biological, physical, and chemical oceanographic data since 1988. At 4728 m water depth, it is the world's deepest operating cabled observatory. On-going results will be presented along with results from two new instrument packages to be deployed: a basic sensor package (CTDO2, fluorometer, acoustic modem, ADCP), and a video/light/hydrophone combination. Plans for future research will be discussed. [Work supported by the National Science Foundation.

  5. SSME Electrical Harness and Cable Development and Evolution

    Science.gov (United States)

    Abrams, Russ; Heflin, Johnny; Burns, Bob; Camper, Scott J.; Hill, Arthur J.

    2010-01-01

    The Space Shuttle Main Engine (SSME) electrical harness and cable system consists of the various interconnecting devices necessary for operation of complex rocket engine functions. Thirty seven harnesses incorporate unique connectors, backshell adapters, conductors, insulation, shielding, and physical barriers for a long maintenance-free life while providing the means to satisfy performance requirements and to mitigate adverse environmental influences. The objective of this paper is to provide a description of the SSME electrical harness and cable designs as well as the development history and lessons learned.

  6. Statistical Distribution of Energization Overvoltages of EHV Cables

    DEFF Research Database (Denmark)

    Ohno, Teruo; Bak, Claus Leth; Ametani, Akihiro

    2013-01-01

    Statistical distributions of switching overvoltages have been used for decades for the determination of insulation levels of extremely high voltage (EHV) systems. Existing statistical distributions obtained in the 1970s are for overhead lines, and statistical distributions of switching overvoltages...... those on the overhead lines with respect to maximum, 2%, and mean values. As the minimum value is almost at the same level, standard deviations are smaller for the cables. The obtained statistical distributions in this paper are of a great importance in considering insulation levels of cable systems....

  7. Seismic Passive Control of Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    Hosam-Eddin M. Ali

    1995-01-01

    Full Text Available A three-dimensional modeling procedure is proposed for cable-stayed bridges with rubber, steel, and lead energy dissipation devices. The passive control technique is investigated by considering the response of bridge models with and without energy dissipation devices. The impact of various design parameters on the seismic response of current and future bridge designs is studied. Appropriate locations and properties of the passive devices can achieve better performance for cable-stayed bridges by balancing the significant reduction in earthquake-induced forces against tolerable displacements. Proper design of passive systems can help provide solutions for retro-fitting some existing bridges.

  8. Semi-active control of stay cables using nonlinear friction damper

    Science.gov (United States)

    Wang, Huiping; Sun, Limin

    2013-04-01

    Stay cables of long span cable-stayed bridges are easy to vibrate under wind or wind/rain loads owning to their very low inherent damping. To install cable dampers near to the anchorages of cable has become a common practice for cable vibration control of cable-stayed bridge structures. The performance of passive linear viscous dampers has been widely studied. However, even the optimal passive device can only add a small amount of damping to the cable when attached a reasonable distance from the cable anchorage. This paper investigates the potential for improved damping using semiactive devices based on nonlinear frictional type of dampers. The equations of motion of a cable with a friction damper were derived using an assumed modes approach and the analytical solution for the motion equations was obtained. The results show that the friction damper evokes linearly decaying of free vibrations of the cable as long as the damper does not lock the cable. The equivalent modal damping ratio of cable with the friction damper is strongly amplitude dependent. Based on the characteristics of friction damper, the authors proposed a semi-active control strategy for cable control with dampers. According to the semi-active control law, the damper force has to be adjusted in proportion to the cable amplitude at damper position. The effectiveness of passive linear viscous dampers is reviewed. The response of a cable with passive and semi-active dampers is studied. The response with a semi-active damper is found to be dramatically reduced compared to the optimal passive linear viscous damper, thus demonstrating the potential benefits using a semi-active damper for absorbing cable vibratory energy.

  9. Comparison of losses in an armoured and unarmoured three phase cable

    DEFF Research Database (Denmark)

    Ebdrup, Thomas; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2015-01-01

    In this article, measurements of a 245 kV 3x1x630 mm2 armoured and unarmoured cable is presented along with a description of the data processing of the measured quantities. The results of the measurements show that the losses in the armoured cable are larger than the losses in the unarmoured cable....... The measurements also show that the equivalent phase resistance of the cable increases as a function of the current....

  10. New method of trenchless cable replacement by the new HDD wash over technology

    Directory of Open Access Journals (Sweden)

    Hans-Joachim Bayer

    2007-01-01

    Full Text Available An enormous amount of underground electricity and telecommunication cables have become time-worn technical defects or need a capacity increase. Thus, new lines need to be installed. In urban areas, even in smaller communities and in nature reserves, open trenching is difficult and often not permitted.New patented methods of trenchless cable replacement by using the HDD equipment have been developed by the TT Group. The new technology is called “Wash-over-cable-replacement” and applies specially designed drill heads, reaming around the old cable string in various configurations (completely closed, U-shaped or sigmoidal embracing, depending on the coating structure of the old cable. The cable replacement drill heads separate the cable from adhesive or contacting soil or sand bedding, create a very small annular space around the cable which enables a pulling or dragging out of the old cable section between a start and an exit pit. After the old cable has been loosened from the surrounding soil by means of the wash over process and pulled out, the new cable is smoothly pulled into the void using the drill rods embedding the new cable into a rich bed of Bentonite.The replacement drill heads are slim and have inner and outer nozzles for Bentonite and bits in order to handle roots, pebbles, gravel and the like. These drill heads can very fast (up to 3 meters per minute and effectively wash over existing cables without damaging the cable coating and prepare the ground for a fast new laying of a new cable in the existing line. Network owners also benefit from the fact that new geodetic or topographic surveys and documentations of the new cable are not necessary, only, the documents, remarks, technical codes and existing geodetic data need to be updated.The paper will outline the technological background and includes many practical job examples.

  11. Fabrication of a superconducting cable for construction of Hi-Lumi Magnet

    CERN Multimedia

    2016-01-01

    A Rutherford cabling machine is operated in the superconducting laboratory in building 163. The machine was used for the production of the Nb-Ti cables in the LHC magnets. Today, it is operated for the assembly of the high-performance cables made from state-of-the-art Nb3Sn conductor. The video shows the production of a long length Nb3Sn cable that will be use in a 11 T High Luminosity LHC dipole magnet.

  12. An Overview of the Development for Cable-Driven Parallel Manipulator

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Tang

    2014-02-01

    Full Text Available In the last two decades, cable-driven parallel robots have attracted a lot of attention in robot community as a hot topic of robot research. In this paper, the development of the cable-driven parallel manipulator is first introduced in general. Second, the latest advance in theory and applications of cable-driven parallel manipulator is presented in detail, especially some notable implementations. Finally, an other probable application foresight with this cable manipulator is proposed and discussed.

  13. Optimizing of the cable bedding and the ampacity of underground power cables in trefoil formation by using the gravitational search algorithm

    Directory of Open Access Journals (Sweden)

    Perović Bojan D.

    2016-01-01

    Full Text Available This paper considers the problem of the determination of the optimum values for dimensions of cable trench and cable bedding, interaxial spacings between power cables in trefoil formation and cable ampacities. This non-linear multi-objective optimization problem with constraints is solved by using the gravitational search algorithm (GSA. The procedure used in this paper has allowed the simultaneous inclusion of all control variables into the optimization process and the determination of an optimal solution in accordance with specified optimization criteria. in the present case, the optimal solution is obtained based on the following optimization criteria: (i minimization of the total installation cost for cable line, (ii maximization of the cable ampacity and (iii a simultaneous application of the minimization of the total installation cost for cable line and the maximization of the cable ampacity. The constraints on control variables are introduced through penalty factors which expand the objective function, it is also assumed that the cable ampacity corresponds to a load factor of 0.8. The procedure is carried out with respect to the drying out effect in the soil surrounding the cables.

  14. Análisis de falla en cable de acero Análisis de falla en cable de acero

    Directory of Open Access Journals (Sweden)

    E. A. Ossa

    2005-12-01

    Full Text Available Este artículo describe el análisis de falla realizado en dos muestras de cables de acero que sufrieron falla súbita bajo condiciones de carga de trabajo normales. La falla fue causada por una carga menor a la capacidad nominal. Luego de inspección óptica se evidenció que la falla fue ocasionada por fatiga del material de uno de los cables.This paper describes the failure analysis of two wire ropes fractured during normal working conditions. The failure was caused by a load well below the nominal maximum resistance of the ropes. Optical microscopy indicated fatigue failure of one of the cables.

  15. Crystal River 3 Cable Materials for Thermal and Gamma Radiation Aging

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Correa, Miguel [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zwoster, Andy [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-07

    The Expanded Materials Degradation Assessment Volume 5: Aging of Cables and Cable Systems (EMDA) summarizes the state of knowledge of materials, constructions, operating environments, and aging behavior of low voltage and medium cables in nuclear power plants (NPPs) and identifies potential knowledge gaps with regard to cable operation beyond 60 years. The greatest area of uncertainty relates to how well the accelerated aging used in the original equipment qualification (EQ) processes predicts the performance of cable materials in extended operation. General opinion and utility experience have indicated that actual operating environments of in-plant cables are not as severe, however, as the operating and design basis environments used in the qualification process. Better understanding of the long term aging behavior of cable insulation materials in service conditions and the analysis of actual cable operating environments are the objectives of ongoing research to support subsequent license renewal activities in particular and long term cable aging management in general. A key component of the effort to better understand cable material aging behavior is the availability of representative samples of cables that have been installed in operating light water reactors and have experienced long term service. Unique access to long term service cables, including relatively rich information on cable identity and history, occurred in 2016 through the assistance of the Electric Power Research Institute (EPRI). EPRI facilitated DOE receipt of harvested cables from the decommissioned Crystal River Unit 3 (CR3) pressurized water reactor representing six of the nine most common low voltage cable manufacturers (EPRI 103841R1): Rockbestos, Anaconda Wire and Cable Company (Anaconda), Boston Insulated Wire (BIW), Brand-Rex, Kerite and Okonite. Cable samples received had been installed in the operating plant for durations ranging from 10 years to 36 years. These cables provide the

  16. Cable Overheating Risk Warning Method Based on Impedance Parameter Estimation in Distribution Network

    Science.gov (United States)

    Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao

    2017-05-01

    Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.

  17. AC losses in a prototype NbTi cable for LHC dipole magnets

    NARCIS (Netherlands)

    Roovers, A.J.M.; van Pelt, A.J.; van de Klundert, L.J.M.

    1990-01-01

    In this paper loss measurements on a prototype NbTi cable for the Large Hadron Collider dipole magnets are presented. The cable is meant to be used for the outer layer of the magnets. It is a trapezium-shaped (key-stoned) Rutherford cable. The experimental results were obtained in a Twente test

  18. Parametric studh on coupling loss in subsize ITER Nb3Sn cabled specimens

    NARCIS (Netherlands)

    Nijhuis, Arend; ten Kate, Herman H.J.; Bruzzone, Pierluigi; Bottura, Luca

    1996-01-01

    The cable in conduit conductors for the various ITER coils are required to function under pulse conditions and fields up to 13 T. A parametric study, restricted to a limited variation of the reference cable lay out, is carried out to clarify the quantitative impact of various cable parameters on the

  19. 47 CFR 76.1611 - Political cable rates and classes of time.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Political cable rates and classes of time. 76... SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Notices § 76.1611 Political cable rates and classes of time. If a system permits a candidate to use its cablecast facilities, the system shall...

  20. Lightning in hybrid cable-overhead lines and consequent transient overvoltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Schultz Pedersen, Kasper; Bak, Claus Leth

    2017-01-01

    Whereas lines that consist entirely of underground cable are naturally protected from lightning, the phenomenon must be considered for lines that are a mix of overhead lines and underground cables. The difference between overhead lines and underground cables wave impedances may lead to transient......, Transient Overvoltages...

  1. Network Patch Cables Demystified: A Super Activity for Computer Networking Technology

    Science.gov (United States)

    Brown, Douglas L.

    2004-01-01

    This article de-mystifies network patch cable secrets so that people can connect their computers and transfer those pesky files--without screaming at the cables. It describes a network cabling activity that can offer students a great hands-on opportunity for working with the tools, techniques, and media used in computer networking. Since the…

  2. Canadian Cable Television and Education. New Technologies in Canadian Education Series. Paper 10.

    Science.gov (United States)

    Rosen, Thelma; Wieczorek, Conrad

    This paper identifies some of the major developments and activities in cable television in relation to education in Canada. It begins by providing a general overview of the cable industry from 1952 to 1983, including the revision of the Broadcasting Act in 1968 to give jurisdiction over the cable television industry to the newly created Canadian…

  3. 77 FR 24228 - Condition Monitoring Techniques for Electric Cables Used in Nuclear Power Plants

    Science.gov (United States)

    2012-04-23

    ... COMMISSION Condition Monitoring Techniques for Electric Cables Used in Nuclear Power Plants AGENCY: Nuclear... Techniques for Electric Cables Used in Nuclear Power Plants.'' This guide describes techniques that the staff of the NRC considers acceptable for condition monitoring of electric cables for nuclear power plants...

  4. Recent developments in cabling technology used to manufacture superconducting accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Royet, J.; Scanlan, R.M.

    1993-09-20

    The cable is the heart of superconducting accelerator magnets. Since the initial development of the Rutherford cable, more than twenty years ago, many improvements in manufacturing techniques have increased the current carrying capacity. An experimental cabling machine was designed and constructed at LBL in 1984.

  5. 30 CFR 75.810 - High-voltage trailing cables; splices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; splices. 75.810... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.810 High-voltage trailing cables; splices. In the case of high-voltage cables used as trailing...

  6. 30 CFR 75.907 - Design of trailing cables for medium-voltage circuits.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Design of trailing cables for medium-voltage... Medium-Voltage Alternating Current Circuits § 75.907 Design of trailing cables for medium-voltage circuits. Trailing cables for medium-voltage circuits shall include grounding conductors, a ground check...

  7. 30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; minimum design... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.804 High-voltage trailing cables; minimum design requirements. (a) High-voltage trailing cables used in resistance grounded systems shall be...

  8. Effect of gland quality on the screening effectiveness of cable-connector assemblies

    NARCIS (Netherlands)

    Deschénes, Patrick; Bijman, Rob; Leferink, Frank Bernardus Johannes

    2015-01-01

    An extensive number of standards provide various transfer impedance requirements and test methods for individual cables, but just a few are related to connectors. Only two stand-ards describe how to test cable-gland-connector-receptacle as-semblies. The cable-gland-connector receptacle assembly has

  9. Numerical solution of the transverse resistivity of superconducting cables under AC conditions

    NARCIS (Netherlands)

    Hartmann, R.A.; Hartmann, R.A.; van Beckum, F.P.H.; van de Klundert, L.J.M.; van de Klundert, L.J.M.; Dijkstra, D.

    1989-01-01

    The authors develop a numerical method for calculating the transverse resistivity of superconducting cables. A superconducting cable consists of a twisted bundle of strands with a nonconducting inner region. If such a cable is placed in an external magnetic field, the induced currents will not

  10. Cost of wetland protection using a Christy cable yarder

    Science.gov (United States)

    Chris B. LeDoux; John E. Baumgras; Edwin S. Miyata

    1990-01-01

    Forest managers, loggers, land-use planners, and other decision makers need an understanding of estimating the cost of protecting wetlands using cable logging systems to harvest timber products. Results suggest that protection costs can range from $245 to $490 per acre depending on the degree of protection desired.

  11. Metal clad aramid fibers for aerospace wire and cable

    Science.gov (United States)

    Tokarsky, Edward W.; Dunham, Michael G.; Hunt, James E.; Santoleri, E. David; Allen, David B.

    1995-01-01

    High strength light weight metal clad aramid fibers can provide significant weight savings when used to replace conventional metal wire in aerospace cable. An overview of metal clad aramid fiber materials and information on performance and use in braided electrical shielding and signal conductors is provided.

  12. A superconducting transformer system for high current cable testing.

    Science.gov (United States)

    Godeke, A; Dietderich, D R; Joseph, J M; Lizarazo, J; Prestemon, S O; Miller, G; Weijers, H W

    2010-03-01

    This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10,464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

  13. Long span cable supported bridges - present technology and trends

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    1998-01-01

    The activity within the field of long-span cable supported bridges has never been larger than at the end of the 20th century. The technology is well advanced to cope with the present challenges but it is also approaching its limits so if the trend towards ever increasing spans continues...

  14. Considerations about an improved superconducting cable for Linear Collider Detectors

    CERN Document Server

    Gaddi, A

    2009-01-01

    This note puts together arguments, discussed within the Linear Collider Detector community in the last months, about setting up an R&D program aiming to demonstrate the industrial feasibility and build a significant prototype length (tbd) of superconducting cable for next HEP detector magnets.

  15. Probabilistic Approach to Fatigue Assessment for Stay Cables

    DEFF Research Database (Denmark)

    Baussaron, Julien; Sørensen, John Dalsgaard; Toft, Henrik Stensgaard

    2013-01-01

    Many parameters used for predicting times to failure of structure due to fatigue are uncertain and their variations have a big influence on the real lifetime. This paper focus on a global methodology to take main sources of variability in fatigue prediction for stay cables into account. The first...

  16. Cryostat for a high-temperature superconducting power cable

    NARCIS (Netherlands)

    Chevtchenko, O.A.; Smit, J.J.; Geschiere, A.

    2010-01-01

    Cryostat for a high-temperature superconducting power cable, comprising concentric tubes, an annular region between said tubes, wherein a multilayer thermal insulation and getter material for supporting high vacuum conditions are provided in said annular region, and wherein the multilayer insulation

  17. Real Time Load Optimisation of Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Guðmundsdottir, Unnur Stella

    2011-01-01

    Energinet.dk has launched an investigation of dynamic current ratings of cable based transmission grids, where both internal and external parameters are variables. The first topic was to investigate state of the art within calculating the current carrying capacity (ampacity or loadability...

  18. MIMO Terminal Performance Evaluation with a Novel Wireless Cable Method

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Hentilä, Lassi

    2017-01-01

    Conventional conductive method, where antennas on the device under test (DUT) are disconnected from antenna ports and replaced with radio frequency (RF) coaxial cables, has been dominantly utilized in industry to evaluate multiple-input multiple-output (MIMO) capable terminals. However, direct RF...

  19. Adaptive Semiactive Cable Vibration Control: A Frequency Domain Perspective

    Directory of Open Access Journals (Sweden)

    Z. H. Chen

    2017-01-01

    Full Text Available An adaptive solution to semiactive control of cable vibration is formulated by extending the linear quadratic Gaussian (LQG control from time domain to frequency domain. Frequency shaping is introduced via the frequency dependent weights in the cost function to address the control effectiveness and robustness. The Hilbert-Huang transform (HHT technique is further synthesized for online tuning of the controller gain adaptively to track the cable vibration evolution, which also obviates the iterative optimal gain selection for the trade-off between control performance and energy in the conventional time domain LQG (T-LQG control. The developed adaptive frequency-shaped LQG (AF-LQG control is realized by collocated self-sensing magnetorheological (MR dampers considering the nonlinear damper dynamics for force tracking control. Performance of the AF-LQG control is numerically validated on a bridge cable transversely attached with a self-sensing MR damper. The results demonstrate the adaptivity in gain tuning of the AF-LQG control to target for the dominant cable mode for vibration energy dissipation, as well as its enhanced control efficacy over the optimal passive MR damping control and the T-LQG control for different excitation modes and damper locations.

  20. Fusion reactor handling operations with cable-driven parallel robots

    Energy Technology Data Exchange (ETDEWEB)

    Izard, Jean-Baptiste, E-mail: jeanbaptiste.izard@tecnalia.com; Michelin, Micael; Baradat, Cédric

    2015-10-15

    Highlights: • CDPR allow 6DOF positioning of loads using cable as links without payload swag. • Conceptual design of a CDPR for carrying and positioning tokamak sectors is given. • A CDPR for threading stellarator coils (6D trajectory following) is provided. • Both designs are capable of fullfilling the required precision without tooling. - Abstract: Cable-driven parallel robots (CDPR) are in their concept cranes with inclined cables which allow control of all the degrees of freedom of its payload, and therefore stability of all the degrees of freedom, including rotations. The workspace of a CDPR is only limited by the length of the cables, and the payload capacity related to the mass of the whole robot is very important. Besides, the control being based on kinematic models, the behavior of a CDPR is really that of a robot capable of automated trajectories or remote handling. The present paper gives a presentation of two use case studies based on some of the assembly phases and remote handling actions as designed for the recent fusion machines. Based on the use cases already in place in fusion reactor baselines, the opportunity of using CDPR for assembly of structural elements and coils is discussed. Finally, prospects for remote handling equipment from the reactor in hot cells are envisioned based on current CDPR research.

  1. A second look at cable logging in the Appalachians

    Science.gov (United States)

    Harry G. Gibson; Cleveland J. Biller

    1975-01-01

    Cable logging, once used extensively in the Appalachians, is being re-examined to see if smaller, more mobile systems can help solve some of the timber-managment problems on steep slopes. A small Austrian skyline was tested in West Virginia to determine its feasibility for harvesting enstern hardwoods. The short-term test included both selection and clearcut harvesting...

  2. Layout Of Antennas And Cables In A Large Array

    Science.gov (United States)

    Logan, Ronald T., Jr.

    1995-01-01

    Layout devised to minimize total land area occupied by large phased array of antennas and to minimize total length of cables in array. In original intended application, array expanded version of array of paraboloidal-dish microwave communication antennas of Deep Space Network. Layout also advantageous for other phased arrays of antennas and antenna elements, including notably printed-circuit microwave antenna arrays.

  3. Layout and cabling considerations for a large communications antenna array

    Science.gov (United States)

    Logan, R. T., Jr.

    1993-01-01

    Layout considerations for a large deep space communications antenna array are discussed. A fractal geometry for the antenna layout is described that provides optimal packing of antenna elements, efficient cable routing, and logical division of the array into identical sub-arrays.

  4. 77 FR 61351 - Cable Television Technical and Operational Requirements

    Science.gov (United States)

    2012-10-09

    ... section 624(e) of the Communications Act to establish a statutory mandate for cable TV signal quality... on rules that would update its minimum signal quality standards and signal leakage detection and... accuracy of the Commission's burden estimates; (c) ways to enhance the quality, utility, and clarity of the...

  5. MVAC Submarine cable, magnetic fields measurements and analysis

    DEFF Research Database (Denmark)

    Expethit, Adrian; Sørensen, Sebastian Bille; Arentsen, Martin Trolle

    2017-01-01

    to measure how the magnetic field varies between wires, above a wire, inside the wire arrangement and at sections without armour. The magnetic field tests are compared to a COMSOL model of the specified cable showing good compliance between experimental and simulated results. It is concluded that at low core...

  6. Probabilistic FE analysis of a cable stayed composite bridge

    NARCIS (Netherlands)

    Boer, A. de; Waarts, P.H.

    1999-01-01

    This paper describes the design of a new cable stayed composite bridge near Kampen in the Netherlands. In the design process, the safety of bridges is insured by means of partial safety factors for both strength and load parameters. As a result it is generally accepted that the structure as a whole

  7. 30 CFR 18.36 - Cables between machine components.

    Science.gov (United States)

    2010-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction... circuits extending from permissible equipment will be exempted from the requirements of conduit enclosure... heavy jackets, the sizes of which are stated in Table 6 of Appendix I. Cables (cords) provided with hose...

  8. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research...

  9. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students resea...

  10. 78 FR 11987 - Cable Television Act of 1992

    Science.gov (United States)

    2013-02-21

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 76 Cable Television Act of 1992 AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of effective date. SUMMARY: This document announces the effective date of rules...

  11. 78 FR 11988 - Cable Television Act of 1992

    Science.gov (United States)

    2013-02-21

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 76 Cable Television Act of 1992 AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of effective date. SUMMARY: This document announces the effective date of rules...

  12. 75 FR 59099 - Cable Television Act of 1992

    Science.gov (United States)

    2010-09-27

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 76 Cable Television Act of 1992 AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of effective date. SUMMARY: This document announces the effective date of rules...

  13. Integrated cable vibration control system using wireless sensors

    Science.gov (United States)

    Jeong, Seunghoo; Cho, Soojin; Sim, Sung-Han

    2017-04-01

    As the number of long-span bridges is increasing worldwide, maintaining their structural integrity and safety become an important issue. Because the stay cable is a critical member in most long-span bridges and vulnerable to wind-induced vibrations, vibration mitigation has been of interest both in academia and practice. While active and semi-active control schemes are known to be quite effective in vibration reduction compared to the passive control, requirements for equipment including data acquisition, control devices, and power supply prevent a widespread adoption in real-world applications. This study develops an integrated system for vibration control of stay-cables using wireless sensors implementing a semi-active control. Arduino, a low-cost single board system, is employed with a MEMS digital accelerometer and a Zigbee wireless communication module to build the wireless sensor. The magneto-rheological (MR) damper is selected as a damping device, controlled by an optimal control algorithm implemented on the Arduino sensing system. The developed integrated system is tested in a laboratory environment using a cable to demonstrate the effectiveness of the proposed system on vibration reduction. The proposed system is shown to reduce the vibration of stay-cables with low operating power effectively.

  14. Status of the LHC Superconducting Cable Mass Production

    CERN Document Server

    Adam, J D; Cavallari, Giorgio; Charifoulline, Z; Denarié, C H; Le Naour, S; Leroy, D F; Oberli, L R; Richter, D; Verweij, A P; Wolf, R

    2002-01-01

    Six contracts have been placed with industrial companies for the production of 1200 tons of the superconducting (SC) cables needed for the main dipoles and quadrupoles of the Large Hadron Collider (LHC). In addition, two contracts have been placed for the supply of 470 tons of NbTi and 26 tons of Nb sheets. The main characteristic of the specification is that it is functional. This means that the physical, mechanical and electrical properties of strands and cables are specified without defining the manufacturing processes. Facilities for the high precision measurements of the wire and cable properties have been implemented at CERN, such as strand and cable critical current, copper to superconductor ratio, interstrand resistance, magnetisation, RRR at 4.2 K and 1.9 K. The production has started showing that the highly demanding specifications can be fulfilled. This paper reviews the organisation of the contracts, the test facilities installed at CERN, the various types of measurements and the results of the ma...

  15. Torsional Buckling and Writhing Dynamics of Elastic Cables and DNA

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, S; Perkins, N C; Lee, C L

    2003-02-14

    Marine cables under low tension and torsion on the sea floor can undergo a dynamic buckling process during which torsional strain energy is converted to bending strain energy. The resulting three-dimensional cable geometries can be highly contorted and include loops and tangles. Similar geometries are known to exist for supercoiled DNA and these also arise from the conversion of torsional strain energy to bending strain energy or, kinematically, a conversion of twist to writhe. A dynamic form of Kirchhoff rod theory is presented herein that captures these nonlinear dynamic processes. The resulting theory is discretized using the generalized-method for finite differencing in both space and time. The important kinematics of cross-section rotation are described using an incremental rotation ''vector'' as opposed to traditional Euler angles or Euler parameters. Numerical solutions are presented for an example system of a cable subjected to increasing twist at one end. The solutions show the dynamic evolution of the cable from an initially straight element, through a buckled element in the approximate form of a helix, and through the dynamic collapse of this helix through a looped form.

  16. Modelling of wander ratios, travel speeds and productivity of cable ...

    African Journals Online (AJOL)

    The objective of this study was to develop predictive models for cable and grapple skidder wander ratios, travel speeds (loaded and unloaded), and productivity in softwood roundwood sawtimber harvesting operations. For field data collection, the study utilised on-board computing systems supported by manual time study.

  17. Subsea Cable Tracking by Autonomous Underwater Vehicle with Magnetic Sensing Guidance.

    Science.gov (United States)

    Xiang, Xianbo; Yu, Caoyang; Niu, Zemin; Zhang, Qin

    2016-08-20

    The changes of the seabed environment caused by a natural disaster or human activities dramatically affect the life span of the subsea buried cable. It is essential to track the cable route in order to inspect the condition of the buried cable and protect its surviving seabed environment. The magnetic sensor is instrumental in guiding the remotely-operated vehicle (ROV) to track and inspect the buried cable underseas. In this paper, a novel framework integrating the underwater cable localization method with the magnetic guidance and control algorithm is proposed, in order to enable the automatic cable tracking by a three-degrees-of-freedom (3-DOF) under-actuated autonomous underwater vehicle (AUV) without human beings in the loop. The work relies on the passive magnetic sensing method to localize the subsea cable by using two tri-axial magnetometers, and a new analytic formulation is presented to compute the heading deviation, horizontal offset and buried depth of the cable. With the magnetic localization, the cable tracking and inspection mission is elaborately constructed as a straight-line path following control problem in the horizontal plane. A dedicated magnetic line-of-sight (LOS) guidance is built based on the relative geometric relationship between the vehicle and the cable, and the feedback linearizing technique is adopted to design a simplified cable tracking controller considering the side-slip effects, such that the under-actuated vehicle is able to move towards the subsea cable and then inspect its buried environment, which further guides the environmental protection of the cable by setting prohibited fishing/anchoring zones and increasing the buried depth. Finally, numerical simulation results show the effectiveness of the proposed magnetic guidance and control algorithm on the envisioned subsea cable tracking and the potential protection of the seabed environment along the cable route.

  18. Subsea Cable Tracking by Autonomous Underwater Vehicle with Magnetic Sensing Guidance

    Directory of Open Access Journals (Sweden)

    Xianbo Xiang

    2016-08-01

    Full Text Available The changes of the seabed environment caused by a natural disaster or human activities dramatically affect the life span of the subsea buried cable. It is essential to track the cable route in order to inspect the condition of the buried cable and protect its surviving seabed environment. The magnetic sensor is instrumental in guiding the remotely-operated vehicle (ROV to track and inspect the buried cable underseas. In this paper, a novel framework integrating the underwater cable localization method with the magnetic guidance and control algorithm is proposed, in order to enable the automatic cable tracking by a three-degrees-of-freedom (3-DOF under-actuated autonomous underwater vehicle (AUV without human beings in the loop. The work relies on the passive magnetic sensing method to localize the subsea cable by using two tri-axial magnetometers, and a new analytic formulation is presented to compute the heading deviation, horizontal offset and buried depth of the cable. With the magnetic localization, the cable tracking and inspection mission is elaborately constructed as a straight-line path following control problem in the horizontal plane. A dedicated magnetic line-of-sight (LOS guidance is built based on the relative geometric relationship between the vehicle and the cable, and the feedback linearizing technique is adopted to design a simplified cable tracking controller considering the side-slip effects, such that the under-actuated vehicle is able to move towards the subsea cable and then inspect its buried environment, which further guides the environmental protection of the cable by setting prohibited fishing/anchoring zones and increasing the buried depth. Finally, numerical simulation results show the effectiveness of the proposed magnetic guidance and control algorithm on the envisioned subsea cable tracking and the potential protection of the seabed environment along the cable route.

  19. Field Test and Simulation of a 400 kV Cross-Bonded Cable System

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Gustavsen, Bjørn; Bak, Claus Leth

    2011-01-01

    This paper discusses cable modeling for long high voltage AC underground cables. In investigating the possibility of using long cables instead of overhead lines, the simulation results must be trustworthy. Therefore, model validation is of great importance. This paper gives a benchmark case...... for measurements on a 400 kV cable system with cross bonded sheaths. The paper describes in detail the modeling procedure for the cable system and compares simulation results with the transient field test results. It is shown that although the main characteristics of the waveforms are well reproduced...

  20. Identification of aeroelastic forces on bridge cables from full-scale measurements

    DEFF Research Database (Denmark)

    Acampora, Antonio; Macdonald, J.H.G.; Georgakis, Christos

    2011-01-01

    Despite much research in recent years, large amplitude vibrations of inclined cables continue to be of concern for cable-stayed bridges. Various mechanisms have been suggested for their excitation, including rain-wind excitation, dry inclined cable galloping, high reduced velocity vortex shedding...... Bridge. The system records wind conditions and weather conditions, as well as accelerations of certain cables and a few locations on the deck and tower. Using state-of-the-art methods of output-only system identification, the vibration modes of the cables have been identified. From these modes...

  1. Research achievements in under-deck and combined cable-stayed bridges

    OpenAIRE

    Ruiz-Teran, Ana M.; Aparicio, Angel C.

    2010-01-01

    Under-deck cable-stayed bridges and combined cable-stayed bridges constitute two innovative bridge types that have been designed and built on only a few occasions over the last thirty years by outstanding structural engineers, such as Leonhardt, Schlaich, Menn, Virlogeux, Manterola, and Cremer. In these bridge types, the stay cables have unconventional layouts: below the deck, in the case of under-deck cable-stayed bridges, and above and below the deck, in the case of combined cable-stayed br...

  2. Manufacturing of superconducting cable for the LHC-Key technology and statistical analysis

    CERN Document Server

    Shimada, T; Nagasu, Y; Takagi, A; Wada, K; Shimizu, H; Kimura, A; Meguro, S

    2002-01-01

    Manufacturing of superconducting cable for the LHC main dipole magnet is in progress at The Furukawa Electric Co., Ltd. (here after referred to as "FEC"). Fabrication technology of Rutherford type cable for accelerator magnets has made a remarkable advance through development of the LHC Cable2 Key technology includes many different things such as multi-filament billet design, assembly, control of copper to superconductor ratio, optimization of thermo-mechanical heat treatment, drawing process, Sn-Ag coating and cabling. The well- balanced Cable2 with high quality was developed, and all of the electrical and mechanical performances met the specification requirements. (7 refs).

  3. Frequency domain reflectometry NDE for aging cables in nuclear power plants

    Science.gov (United States)

    Glass, S. W.; Jones, A. M.; Fifield, L. S.; Hartman, T. S.

    2017-02-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable's ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable's ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that

  4. Human movement training with a cable driven ARm EXoskeleton (CAREX).

    Science.gov (United States)

    Mao, Ying; Jin, Xin; Gera Dutta, Geetanjali; Scholz, John P; Agrawal, Sunil K

    2015-01-01

    In recent years, the authors have proposed lightweight exoskeleton designs for upper arm rehabilitation using multi-stage cable-driven parallel mechanism. Previously, the authors have demonstrated via experiments that it is possible to apply "assist-as-needed" forces in all directions at the end-effector with such an exoskeleton acting on an anthropomorphic machine arm. A human-exoskeleton interface was also presented to show the feasibility of CAREX on human subjects. The goals of this paper are to 1) further address issues when CAREX is mounted on human subjects, e.g., generation of continuous cable tension trajectories 2) demonstrate the feasibility and effectiveness of CAREX on movement training of healthy human subjects and a stroke patient. In this research, CAREX is rigidly attached to an arm orthosis worn by human subjects. The cable routing points are optimized to achieve a relatively large "tensioned" static workspace. A new cable tension planner based on quadratic programming is used to generate continuous cable tension trajectory for smooth motion. Experiments were carried out on eight healthy subjects. The experimental results show that CAREX can help the subjects move closer to a prescribed circular path using the force fields generated by the exoskeleton. The subjects also adapt to the path shortly after training. CAREX was also evaluated on a stroke patient to test the feasibility of its use on patients with neural impairment. The results show that the patient was able to move closer to a prescribed straight line path with the "assist-as-needed" force field.

  5. MARS: a cabled observatory testbed in Monterey Bay

    Science.gov (United States)

    McNutt, M.; Massion, G.; Raybould, K.; Bellingham, J.; Paull, C.

    2003-04-01

    With funding from the U.S. National Science Foundation and the David and Lucile Packard Foundation, the Monterey Bay Aquarium Research Institute (MBARI) will be installing a deep-sea observatory in Monterey Bay, California, that will serve as a test bed for a future regional-scale cabled observatory. Monterey Bay offers a variety of active processes for scientific inquiry, including a very productive zone of ocean upwelling, a seismically active strand of the San Andreas fault system, cold seeps, and a very dynamic submarine canyon. The MARS (Monterey Accelerated Research System) cable will extend more than 60 km offshore to an instrument node at a depth of approximately 1.2 km. Extension cords can be run by remotely operated vehicles (ROVs) from the cable node up to several kilometers away in order to provide greater flexibility in siting instruments. The observatory will be serviced using ROVs and will serve as a test bed for developing new sensors, instruments systems, experiment protocols, and mobile platforms for which submarine cables will provide power and two-way communications. In addition to serving as a test bed for instrumentation and platforms, the MARS project will demonstrate models for how to operate, service, and manage a community facility of this sort. In cooperation with our outreach partner, the Monterey Bay Aquarium, we will be examining ways to exploit the full potential of deep-sea observatories for student education and public information. We will also be preparing a proposal to the Integrated Ocean Drilling Program (IODP) to provide a nearby drill hole for connecting bore-hole experiments to the MARS cable, thereby accelerating the development of new tools for probing Earth beneath the oceans.

  6. Assessment of the burning behavior of protected and unprotected cables and cable trays in nuclear installations using small- and large-scale experiments

    Energy Technology Data Exchange (ETDEWEB)

    Siemon, Matthias; Riese, Olaf; Zehfuss, Jochen [Technische Univ. Braunschweig (Germany). Inst. fuer Baustoffe, Massivbau und Brandschutz (iBMB)

    2015-12-15

    Electric installations and cables are a main fire risk source in industrial buildings and power plants. In general, cables and cable systems are associated with flash-over phenomena due to pyrolysis of fuel gases induced by the heat of an adjacent fire, fire spread along cable trays affecting additional areas besides the fire origin, being an ignition source due to malfunction. If burning, cables can emit large amounts of smoke and toxic products affecting occupants as well as the long-term functionality of structure and installations. Paying attention to these risks has led to the development of fire retardant non-corrosive (non-halogenated) cables which are qualified to reduce the individual or all of the risks mentioned. For existing installations in industrial buildings and power plants with halogenated cables, different protection measures are available and widely applied retroactively. Important protective measures are intumescent or ablative coatings, cable casings and bindings. For qualification of the effects of the protection measures, small-scale tests investigating a single cable specimen as well as large-scale cable tray test setups have been developed and carried out in the last 20 years at iBMB. In this paper, these test results are analysed regarding their effects on the heat release, ignition time and fire spread over cable trays. Furthermore, national and international research projects have investigated the burning behaviour of different cable types, tray installations, tray loading and spacing and ventilation conditions. As a conclusion, the main outcomes of past researches are summarized. Influence factors (e.g. pre-heating due to high power utilization, influence of cable aging) which have not been accounted for in detail are emphasized. The modelling of unprotected cables has been internationally studied in recent years. For future applications, the question of applicability of recently developed sub-models on the fire behaviour of protected

  7. Interstrand Coupling Properties of LARP High Gradient Quadrupole Cables in Response to Variations in Cable Design and Heat Treatment Condition

    NARCIS (Netherlands)

    Collings, E.W.; Sumption, M.D.; Majoros, M.; Wang, Xiaorong; Dietderich, D.R.; Yagotyntsev, Kostyantyn; Nijhuis, Arend

    Calorimetric measurement of coupling loss versus frequency has been measured on two sets of cored and uncored large Hadron Collider Accelerator Research Program high gradient quadrupole Nb3Sn Rutherford cables. Studied are the responses of the resulting interstrand contact resistances (ICR) to

  8. The Coupling Fields Characteristics of Cable Joints and Application in the Evaluation of Crimping Process Defects

    Directory of Open Access Journals (Sweden)

    Fan Yang

    2016-11-01

    Full Text Available The internal defects of cable joints always accelerate the deterioration of insulation, until finally accidents can arise due to the explosion of the joints. The formation process of this damage often involves changes in the electromagnetic, temperature and stress distribution of the cable joint, therefore, it is necessary to analyze the electromagnetic-thermal-mechanical distribution of cable joints. Aiming at solving this problem, the paper sets up a 3-D electromagnetic-thermal-mechanical coupling model of cable joints under crimping process defects. Based on the model, the electromagnetic losses distribution, temperature distribution and stress distribution of a cable joint and body are calculated. Then, the coupling fields characteristics in different contact coefficient k, ambient temperature Tamb and load current I were analyzed, and according to the thermal-mechanical characteristics of a cable joint under internal defects, the temperature difference ΔTf and stress difference Δσf of cable surface are applied to evaluate the internal cable joint defects. Finally, a simplified model of the cable joint is set up to verify the accuracy of the coupling field model proposed in this paper, which indicates that the model can be used to analyze the coupling fields characteristics of cable joints and the method can be applied to evaluate crimping process defects of cable joints.

  9. The use of Classical Rolling Pendulum Bearings (CRPB for vibration control of stay-cables

    Directory of Open Access Journals (Sweden)

    Papastergiou Georgia

    2018-01-01

    Full Text Available Cables are efficient structural elements that are used in cable-stayed bridges, suspension bridges and other cable structures. A significant problem which arose from the praxis is the cables’ rain-wind induced vibrations as these cables are subjected to environmental excitations. Rain-wind induced stay-cable vibrations may occur at different cable eigenfrequencies. Large amplitude Rain-Wind-Induced-Vibrations (RWIV of stay cables are a challenging problem in the design of cable-stayed bridges. Several methods, including aerodynamic or structural means, have been investigated in order to control the vibrations of bridge’s stay-cables. The present research focuses on the effectiveness of a movable anchorage system with a Classical Rolling Pendulum Bearing (CRPB device. An analytical model of cable-damper system is developed based on the taut string representation of the cable. The gathered integral-differential equations are solved through the use of the Lagrange transformation. . Finally, a case study with realistic geometrical parameters is also presented to establish the validity of the proposed system.

  10. Operating experience of the southwire high-temperature superconducting cable project

    Science.gov (United States)

    Hughey, R. L.; Lindsay, D.

    2002-01-01

    Southwire Company of Carrollton, Georgia in cooperation with Oak Ridge National Laboratory has designed, built, installed and is operating the world's first field installation of a High Temperature Superconducting (HTS) cable system. The cables supply power to three Southwire manufacturing facilities and part of the corporate headquarters building in Carrollton, GA. The system consists of three 30-m single phase cables rated at 12.4 kV, 1250 Amps, liquid nitrogen cooling system, and the computer-based control system. The cables are built using BSCCO-2223 powder-in-tube HTS tapes and a proprietary cryogenic dielectric material called Cryoflex™. The cables are fully shielded with a second layer of HTS tapes to eliminate any external magnetic fields. The Southwire HTS cables were first energized on january 6, 2000. Since that time they have logged over 8,500 hours of operation while supplying 100% of the required customer load. To date, the cables have worked without failure and operations are continuing. The cable design has passed requisite testing for this class of conventional cables including 10× over current to 12,500 Amps and BIL testing to 110 kV. Southwire has also successfully designed and tested a cable splice. System heat loads and AC Losses have been measured and compared to calculated values. On June 1, 2001 on-site monitoring was ceased and the system was changed to unattended operation to further prove the reliability of the HTS cable system. .

  11. Experimental Verification for Cable Force Estimation Using Handheld Shooting of Smartphones

    Directory of Open Access Journals (Sweden)

    Xuefeng Zhao

    2017-01-01

    Full Text Available Currently, due to the rapid development and popularization of smartphones, the usage of ubiquitous smartphones has attracted growing interest in the field of structural health monitoring (SHM. The portable and rapid cable force measurement for cable-supported structures, such as a cable-stayed bridge and a suspension bridge, has an important and practical significance in the evaluation of initial damage and the recovery of transportation networks. The extraction of dynamic characteristics (natural frequencies of cable is considered as an essential issue in the cable force estimation. Therefore, in this study, a vision-based approach is proposed for identifying the natural frequencies of cable using handheld shooting of smartphone camera. The boundary of cable is selected as a target to be tracked in the region of interest (ROI of video image sequence captured by smartphone camera, and the dynamic characteristics of cable are identified according to its dynamic displacement responses in frequency domain. The moving average is adopted to eliminate the noise associated with the shaking of smartphone camera during measurement. A laboratory scale cable model test and a pedestrian cable-stayed bridge test are carried out to evaluate the proposed approach. The results demonstrate the feasibility of using smartphone camera for cable force estimation.

  12. Stability analysis of an F/A-18 E/F cable mount m odel

    Science.gov (United States)

    Thompson, Nancy; Farmer, Moses

    1994-01-01

    A full-span F/A-18 E/F cable mounted wind tunnel model is part of a flutter clearance program at the NASA Langley Transonic Dynamics Tunnel. Parametric analysis of this model using GRUMCBL software was conducted to assess stability for wind tunnel tests. Two configurations of the F/A-18 E/F were examined. The parameters examined were pulley-cable friction, mach number, dynamic pressure, cable geometry, center of gravity location, cable tension, snubbing the model, drag, and test medium. For the nominal cable geometry (Cable Geometry 1), Configuration One was unstable for cases with higher pulley-cable friction coefficients. A new cable geometry (Cable Geometry 3) was determined in which Configuration One was stable for all cases evaluated. Configuration Two with the nominal center of gravity position was found to be unstable for cases with higher pulley-cable friction coefficients; however, the model was stable when the center of gravity moved forward 1/2. The model was tested using the cable mount system during the initial wind tunnel entry and was stable as predicted.

  13. Workers in the VAB test SRB cables on STS-98 solid rocket boosters

    Science.gov (United States)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- United Space Alliance SRB technician Richard Bruns attaches a cable end cover to a cable pulled from the solid rocket booster on Space Shuttle Atlantis. The Shuttle was rolled back from Launch Pad 39A in order to conduct tests on the SRB cables. A prior extensive evaluation of NASA'''s SRB cable inventory on the shelf revealed conductor damage in four (of about 200) cables. Shuttle managers decided to prove the integrity of the system tunnel cables already on Atlantis before launching. Workers are conducting inspections, making continuity checks and conducting X-ray analysis on the cables. The launch has been rescheduled no earlier than Feb. 6.

  14. The role of cable stiffness in the dynamic behaviours of submerged floating tunnel

    Directory of Open Access Journals (Sweden)

    Muhammad Naik

    2017-01-01

    Full Text Available Submerged floating tunnel (SFT is a new solution for the transportation infrastructure through sea straits, fjords, and inland waters and can be a good alternative to long span suspension bridges and immersed tunnels. The mooring cables/anchors are main structural components to provide restoring capacity to the SFT. The time domain dynamic problem of SFT moored by vertical and inclined mooring cables/anchors is formulated. The dynamic analysis of SFT subjected to hydrodynamic and seismic excitations is performed. As the cable stiffness determines the deformation ability of SFT, therefore it becomes crucial to evaluate the effect of mooring cable stiffness on the response of SFT. The displacements and internal forces of SFT clearly specify that the vertical/tension leg mooring cables provide very small stiffness as compared to inclined mooring cables. In order to keep the SFT displacements within an acceptable limit, the effect of cable stiffness should be properly evaluated for practical design of SFT.

  15. GENERAL QUESTIONS AS TO PROVIDING ELECTROMAGNETIC COMPATIBILITY OF POWER CABLE LINES, THEIR AMPERAGE CAPACITY AND TYPES OF SHIELD CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    I.A. Kostiukov

    2013-09-01

    Full Text Available Works studying ways of reducing magnetic fields of cross-linked polyethylene power cable lines are reviewed. Different aspects of single-phase power cable shield construction influence on thermal conditions of a three-phase power cable line are analyzed. Questions concerning electromagnetic compatibility of power cables are considered.

  16. Fiber optical cable and connector system (FOCCoS) for PFS/ Subaru

    Science.gov (United States)

    de Oliveira, Antonio Cesar; de Oliveira, Lígia Souza; de Arruda, Marcio V.; Souza Marrara, Lucas; dos Santos, Leandro H.; Ferreira, Décio; dos Santos, Jesulino B.; Rosa, Josimar A.; Junior, Orlando V.; Pereira, Jeferson M.; Castilho, Bruno; Gneiding, Clemens; Junior, Laerte S.; de Oliveira, Claudia M.; Gunn, James; Ueda, Akitoshi; Takato, Naruhisa; Shimono, Atsushi; Sugai, Hajime; Karoji, Hiroshi; Kimura, Masahiko; Tamura, Naoyuki; Wang, Shiang-Yu; Murray, Graham; Le Mignant, David; Madec, Fabrice; Jaquet, Marc; Vives, Sebastien; Fisher, Charlie; Braun, David; Schwochert, Mark; Reiley, Daniel J.

    2014-07-01

    FOCCoS, "Fiber Optical Cable and Connector System" has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition. All optical fibers from Cable C, protected by tubes, pass through the motors' bench plate, three modular plates and a strain relief box, terminating at the Tower Connector. Cable B is permanently installed at Subaru Telescope structure, as a link between Cable C and Cable A. This cable B starts at the Tower Connector device, placed on a lateral structure of the telescope, and terminates at the Gang Connector device. Cable B will be routed to minimize the compression, torsion and bending caused by the cable weight and telescope motion. In the spectrograph room, Cable A starts at the Gang Connector, crosses a

  17. ATOC/Pioneer Seamount cable after 8 years on the seafloor: Observations, environmental impact

    Science.gov (United States)

    Kogan, Irina; Paull, Charles K.; Kuhnz, Linda A.; Burton, Erica J.; von Thun, Susan; Gary Greene, H.; Barry, James P.

    2006-04-01

    A study was conducted on the impacts of the presence of the Acoustic Thermometry of Ocean Climate (ATOC)/Pioneer Seamount cable on the benthos from nearshore waters adjacent to its origin at Pillar Point Air Force Station in Half Moon Bay, California to its terminus 95 km along its length on Pioneer Seamount. The coaxial Type SD cable was installed, unburied on the seafloor in 1995. Thirteen sites along the cable route were surveyed using the Monterey Bay Aquarium Research Institute (MBARI) ROVs Ventana and Tiburon equipped with cable-tracking tools. Quantitative comparisons of biological communities and seafloor features between cable and control sites were performed at nine stations. Forty-two hours of video footage and 138 push cores were collected over 15.1 km of seafloor. Approximately 12.1 km of the cable was observed (13% of the cable route). This study documents the appearance and condition of the cable and the underlying seafloor, and the effects of the cable on biological communities along its route. Limited self-burial of the cable has occurred during the 8-year deployment, particularly over the continental shelf and upper slope. Cable strumming by nearshore wave action has incised rocky siltstone outcrops. Several observations of kinks and snags in the cable on the upper slope (˜240 m depth) suggest contact with trawling gear. Few changes in the abundance or distribution of benthic fauna were detectable from video observations (epifaunal) and sediment core samples (infauna). Of 17 megafaunal groups and 19 infaunal taxa, no tests evaluating the overall effect of the cable were statistically significant. While these results indicate that the biological impacts of the cable are minor at most, three megafaunal groups exhibited cable-related changes at one or more stations. Actiniarians (sea anemones) colonized the cable when it was exposed on the seafloor, and were therefore generally more abundant on the cable than in surrounding, sediment

  18. Assessment of NDE for key indicators of aging cables in nuclear power plants - Interim status

    Science.gov (United States)

    Glass, S. W.; Ramuhalli, P.; Fifield, L. S.; Prowant, M. S.; Dib, G.; Tedeschi, J. R.; Suter, J. D.; Jones, A. M.; Good, M. S.; Pardini, A. F.; Hartman, T. S.

    2016-02-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable's ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored

  19. New Technologies for Repairing Aging Cables in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, Kevin L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westman, Matthew P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-11

    The goal of this project is to demonstrate a proof-of-concept for a technique to repair aging cables that have been subjected to degradation associated with long-term thermal and radiation exposure in nuclear power plants. The physical degradation of the aging cables manifests itself primarily as cracking and increased brittleness of the polymeric electrical insulation. Therefore, the proposed cable-repair concept comprises development of techniques to impart a softening agent within the deteriorated polymer insulation jacket so as to regain the ability of the insulation to stretch without failing and possibly to heal existing cracks in the insulation. Our approach is to use commercially available ethylene-propylene rubber (EPR) as the relevant test material, demonstrate the adsorption of chemical treatments in the EPR and quantify changes in resulting physical and mechanical properties. EPR cable samples have been thermally treated in air to produce specimens corresponding to the full range of cable age-performance points from new (>350% elongation at break) to end-of-life (<50% elongation at break). The current focus is on two chemical treatments selected as candidates for restoring age-related cable elasticity loss: a rubber plasticizer and a reactive silane molecule. EPR specimens of 200, 150, 100, and 50% elongation at break have been soaked in the candidate chemical treatments and the kinetics of chemical uptake, measured by change in mass of the samples, has been determined. Mechanical properties as a function of aging and chemical treatment have been measured including ultimate tensile strength, tensile modulus at 50% strain, elongation at break, and storage modulus. Dimensional changes with treatment and changes in glass transition temperature were also investigated. These ongoing experiments are expected to provide insight into the physical-chemical nature of the effect of thermal degradation on EPR rejuvenation limits and to advance novel methods for

  20. Theoretical and Numerical Analysis of 1 : 1 Main Parametric Resonance of Stayed Cable Considering Cable-Beam Coupling

    Directory of Open Access Journals (Sweden)

    Li-Na Zhang

    2017-01-01

    Full Text Available For the 1 : 1 main parametric resonances problems of cable-bridge coupling vibration, a main parametric resonances model considering cable-beam coupling is developed and dimensionless parametric resonances differential equations are derived. The main parametric resonances characteristics are discussed by means of multiscale approximation solution methods. Using an actual cable of cable-stayed bridge project for research object, numerical simulation analysis under a variety of conditions is illustrated. The results show that when the coupling system causes 1 : 1 parametric resonance, nonlinear main parametric resonances in response are unrelated to initial displacement of the cable, but with the increase of deck beam end vertical initial displacement increases, accompanied with a considerable “beat” vibration. When the vertical initial displacement of deck beam end is 10−6 m order of magnitude or even smaller, “beat” vibration phenomenon of cable and beam appears. Displacement amplitude of the cable is small and considerable amplitude vibration may not occur at this time, only making a slight stable “beat” vibration in the vicinity of the equilibrium position, which is different from 2 : 1 parametric resonance condition of cable-bridge coupling system. Therefore, it is necessary to limit the initial displacement excitation amplitude of beam end and prevent the occurrence of amplitude main parametric excitation resonances.

  1. Field instrumentation and measured response of the I-295 cable-stayed bridge : interim report on construction period strains in cable stays.

    Science.gov (United States)

    1991-01-01

    During the construction of the I-295 cable-stayed bridge, a number of the stays on the main span cantilever were instrumented with electrical resistance strain gages mounted directly on the wires of the seven-wire strands making up the stay cables. M...

  2. Practical cable tension adjustment based upon the satisfaction concept of bridge designers; Sekkeisha no manzokudo wo koryo shita fuzzy cable choryoku choseiho

    Energy Technology Data Exchange (ETDEWEB)

    Kaneyoshi, M.; Tanaka, H. [Hitachi Zosen, Tokyo (Japan)] Furuta, H. [Kansai Univ., Osaka (Japan)

    1998-07-21

    Cable tension adjustment of bridge beam of cable stayed bridge and so forth that uses cable as a structural element is classified into (1) pre-stress adjustment of cable at design level, (2) slim adjustment required at erection level. The former deals with the structurally high dimensional statically indeterminate structures like cable-stayed bridges and is a process for carrying out economical design by making the stress resultant of main girder small due to the introduction of appropriate pre-stress stress on this cable. The later is the process of getting rid off the errors caused in cable tension and camber of girder and tower regarding various errors such as design, fabrication and erection errors. The authors developed analysis method using fuzzy regression analysis and this has been applied in number of practical bridges. In this research, much more practical method is developed where the aspire of designer can be introduced easily by applying the satisfaction concept. By using this, pre-stress adjustment and shim adjustment of cable can be possible in a practical way. 9 refs., 7 figs., 8 tabs.

  3. Impact of cross-tie design on the in-plane stiffness and local mode formation of cable networks on cable-stayed bridges

    Science.gov (United States)

    Ahmad, Javaid; Cheng, Shaohong; Ghrib, Faouzi

    2016-02-01

    Suppressing unfavorable stay cable vibrations using cross-ties is becoming more popular on cable-stayed bridges though the mechanics of the formed cable network is yet fully understood. In practice, the main task in designing cross-ties or cable networks is to choose the cross-tie installation location, stiffness and number based on the main cable properties in the network. To have a more comprehensive picture of how to choose these design parameters to achieve higher in-plane network stiffness while minimizing the number of excited local modes, it is imperative to examine dynamic behavior of cable networks with general configurations. In the current study, an analytical model of a general cable network consisting of multiple main cables interconnected by multiple lines of transverse flexible cross-ties will be developed. A new term, defined as the local mode cluster, will be introduced to assess the severity of local mode excitation. Criteria for identifying the presence of local mode cluster will be proposed. A parametric study will be conducted to evaluate the impact of cross-tie installation location, stiffness and number on the network modal response. Results obtained from the present study will provide deeper insight into the selection of these system parameters to achieve the combined benefits of increasing network in-plane stiffness and minimizing the excitation of local modes.

  4. [Biomechanical performance of different wires and cable fixation devices in posterior instrumentation for atlantoaxial instability].

    Science.gov (United States)

    Liu, Tie-long; Yan, Wang-jun; Han, Yu; Ye, Xiao-jian; Jia, Lian-shun; Li, Jia-shun; Yuan, Wen

    2010-05-01

    To compare the biomechanical performances of different wires and cable fixation devices in posterior instrumentation for atlantoaxial instability, and test the effect of different fixation strengths and fixation approaches on the surgical outcomes. Six specimens of the atlantoaxial complex (C0-C3) were used to establish models of the normal complex, unstable complex (type II odontoid fracture) and fixed complex. On the wd-5 mechanical testing machine, the parameters including the strength and rigidity of anti-rotation, change and strength of stress, and stability were measured for the normal complex, atlantoaxial instability complex, the new type titanium cable fixation system, Atlas titanium cable, Songer titanium cable, and stainless wire. The strength and rigidity of anti-rotation, change and strength of stress, stability of flexion, extension and lateral bending of the unstable atlantoaxial complex fixed by the new double locking titanium cable fixation system were superior to those of the Songer or Atlas titanium cable (Pmedical stainless wire (P<0.05). Simultaneous cable fastening on both sides resulted in better fixation effect than successive cable fastening (P<0.05). Better fixation effect was achieved by fastening the specimen following a rest (P<0.05). The fixation effects can be enhanced by increased fastening strengths. The new type double locking titanium cable fixation system has better biomechanical performance than the conventional Songer and Atlas titanium cables. Fastening the unstable specimens after a rest following simultaneous fastening of the specimen on both sides produces better fixation effect.

  5. Relating Corroded Seven-Strand, Posttensioned Cable Cross-Sectional Properties to Load Capacity

    Directory of Open Access Journals (Sweden)

    Richard Haskins

    2016-01-01

    Full Text Available Multistrand anchors have seen widespread use, providing strength and stability at hydraulic Corps facilities. However, these steel tendons are subject to strength reduction as an effect of corrosion. Methods for evaluating the corroded cable strength do not exist to accurately estimate the time until tendon cables would have to be replaced (at great expense. The following five research tasks are used to address this deficiency: laboratory accelerated corrosion; pull-tests on pristine and laboratory corroded cables; optical scanning; data collection correlated with cross-sectional properties of cables; and development of a method to relate this data to the field. The pull-tests provide measured capacities for seven-strand, posttensioned (PT cables. An optical scan of the corroded cables provides cross-sectional properties of individual wires within the pulled cables. Trendlines are established for the related peak cable capacities and cross-sectional properties in an effort to determine their correlations. Trendlines for minimum wire area and second-moment short axis diameter are found with low error, making them good predictors of loaded cable capacity. This pull-test dataset has been related back to cable failure in the field, assuming a linear rate of corrosion loss for the cross-sectional properties and required PT capacity.

  6. Research on Collapse Process of Cable-Stayed Bridges under Strong Seismic Excitations

    Directory of Open Access Journals (Sweden)

    Xuewei Wang

    2017-01-01

    Full Text Available In order to present the collapse process and failure mechanism of long-span cable-stayed bridges under strong seismic excitations, a rail-cum-road steel truss cable-stayed bridge was selected as engineering background, the collapse failure numerical model of the cable-stayed bridge was established based on the explicit dynamic finite element method (FEM, and the whole collapse process of the cable-stayed bridge was analyzed and studied with three different seismic waves acted in the horizontal longitudinal direction, respectively. It can be found from the numerical simulation analysis that the whole collapse failure process and failure modes of the cable-stayed bridge under three different seismic waves are similar. Furthermore, the piers and the main pylons are critical components contributing to the collapse of the cable-stayed bridge structure. However, the cables and the main girder are damaged owing to the failure of piers and main pylons during the whole structure collapse process, so the failure of cable and main girder components is not the main reason for the collapse of cable-stayed bridge. The analysis results can provide theoretical basis for collapse resistance design and the determination of critical damage components of long-span highway and railway cable-stayed bridges in the research of seismic vulnerability analysis.

  7. Study on Elastic Helical TDR Sensing Cable for Distributed Deformation Detection

    Directory of Open Access Journals (Sweden)

    Qing Li

    2012-07-01

    Full Text Available In order to detect distributed ground surface deformation, an elastic helical structure Time Domain Reflectometry (TDR sensing cable is shown in this paper. This special sensing cable consists of three parts: a silicone rubber rope in the center; a couple of parallel wires coiling around the rope; a silicone rubber pipe covering the sensing cable. By analyzing the relationship between the impedance and the structure of the sensing cable, the impedance model shows that the sensing cable impedance will increase when the cable is stretched. This specific characteristic is verified in the cable stretching experiment which is the base of TDR sensing technology. The TDR experiment shows that a positive reflected signal is created at the stretching deformation point on the sensing cable. The results show that the deformation section length and the stretching elongation will both affect the amplitude of the reflected signal. Finally, the deformation locating experiments show that the sensing cable can accurately detect the deformation point position on the sensing cable.

  8. Study of Materials and Adhesives for Superconducting Cable Feedthroughs

    CERN Document Server

    Perin, A; Métral, L

    2002-01-01

    Powering superconducting magnets requires the use of cryogenic feedthroughs for the superconducting cables capable of withstanding severe thermal, mechanical and electrical operating conditions. Such feedthrough shall provide the continuity of the superconducting circuit while ensuring a hydraulic separation at cryogenic temperature. A study about the adhesive and polymers required for the production of thermal shock resistant feedthroughs is presented. The strength of the busbar to adhesive joints was first investigated by compression/shear tests as well as pin and collar tests performed with four epoxy adhesives. After the selection of the most appropriate adhesive, pin and collar tests were performed with four different polymers. Based on the results, a superconducting cable feedthrough for 6 busbars of 6 kA and 12 busbars of 120 A was constructed and successfully tested.

  9. Dynamic space charge behaviour in polymeric DC cables

    DEFF Research Database (Denmark)

    Rasmussen, Claus Nygaard; Holbøll, Joachim; Henriksen, Mogens

    2002-01-01

    The use of extruded insulation for DC cables involves a risk of local electric field enhancement, caused by a space charge build-up within the dielectric. In this work, the theory of charge generation and transport in polymers is applied in a numerical computer model in order to predict...... the formation and transport of space charges in a polymeric dielectric. The model incorporates the processes of field assisted electron-hole pair generation from impurity atoms, trapping and charge injection at the electrodes. Its aim has been to study the field- and temperature dependent dynamic behaviour...... of a dielectric. Results obtained using this model-based framework are compared to measurement results obtained from Laser Induced Pressure Pulse (LIPP) space charge measurements as well as conductivity measurements on selected cable type samples....

  10. Fireset and Cable Design for Support of Detonator Diagnostic Development

    Science.gov (United States)

    Trujillo, Christopher; Francois, Elizabeth; Gibson, John; Lodes, Rylie; Nakamoto, Teagan; Smith, Dalton; Tasker, Douglas; Parrack, Kristina; Wilde, Zakary

    2017-06-01

    The performance of detonators can be affected by porosity effects in high explosive (HE) materials. In an effort to understand how these effects characterize performance, experiments are to be performed implementing new approaches with advanced diagnostics. This presentation will include the design choices and implementation of diagnostics within two primary components in the experimental test set up, the fire-set and cables. The fire-set contains a current viewing resistor (CVR) which characterizes the electrical performance of the detonator. The cable between the fire-set and detonator includes a Rogowski coil to measure the induced current passing to the detonator. We will present the experimental results and discuss the relevance of these data in the context of the overall experiments.

  11. Cable Capacitance Attack against the KLJN Secure Key Exchange

    Directory of Open Access Journals (Sweden)

    Hsien-Pu Chen

    2015-10-01

    Full Text Available The security of the Kirchhoff-law-Johnson-(like-noise (KLJN key exchange system is based on the fluctuation-dissipation theorem of classical statistical physics. Similarly to quantum key distribution, in practical situations, due to the non-idealities of the building elements, there is a small information leak, which can be mitigated by privacy amplification or other techniques so that unconditional (information-theoretic security is preserved. In this paper, the industrial cable and circuit simulator LTSPICE is used to validate the information leak due to one of the non-idealities in KLJN, the parasitic (cable capacitance. Simulation results show that privacy amplification and/or capacitor killer (capacitance compensation arrangements can effectively eliminate the leak.

  12. Probabilistic Approach to Fatigue Assessment for Stay Cables

    DEFF Research Database (Denmark)

    Baussaron, Julien; Sørensen, John Dalsgaard; Toft, Henrik Stensgaard

    2013-01-01

    points of the structures, develop into critical cracks and failure due to fatigue. Many parameters used for predicting times to failure of structure due to fatigue are uncertain and their variations have a big influence on the real lifetime. This paper will focus on a global methodology to take...... into account main sources of variability in fatigue prediction for stay cables in cable stayed bridges. The first step of this methodology is to model the variability of each parameter. Loading is one of the most important sources of variability. Another important source of variability is the fatigue strength...... of the material. Probabilistic Wöhler curves are fitted using available data, and used to represent the variability of material fatigue behaviour. Finally, the reliability is assessed using Monte Carlo simulations....

  13. Performance Improvement of a Measurement Station for Superconducting Cable Test

    CERN Document Server

    Arpaia, P; Montenero, G; Le Naour, S

    2012-01-01

    A fully digital system, improving measurements flexibility, integrator drift, and current control of superconducting transformers for cable test, is proposed. The system is based on a high-performance integration of Rogowski coil signal and a flexible direct control of the current into the secondary windings. This allows state-of-the-art performance to be overcome by means of out-of-the-shelf components: on a full-scale of 32 kA, current measurement resolution of 1 A, stability below 0.25 Amin-1, and controller ripple less than 50 ppm. The system effectiveness has been demonstrated experimentally on the superconducting transformer of the Facility for the Research of Superconducting Cables at the European Organization for Nuclear Research (CERN).

  14. CABLE MOULDING – MOVEMENT AND DYNAMISM IN ORNAMENT ART

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2013-11-01

    Full Text Available The paper intends to present an ornament, less used in decoration because of the practical difficulties in manufacturing, either manually or in the industrial system. In the paper are presented the elements related to the design (geometry of the cable mouldings, both for constant and variable pitch type and also the kinematics of generating these ornaments. Finally the working schemes of processing these ornaments in the wood industrial system are presented, the ornaments being used to decorate pieces of furniture. The cable moulding type decoration gives to furniture and building products a certain dynamism and vigor, wherefore remains permanently in the attention of designers in construction and furniture fields and also of the interior designers.

  15. Method and device for tensile testing of cable bundles

    Science.gov (United States)

    Robertson, Lawrence M; Ardelean, Emil V; Goodding, James C; Babuska, Vit

    2012-10-16

    A standard tensile test device is improved to accurately measure the mechanical properties of stranded cables, ropes, and other composite structures wherein a witness is attached to the top and bottom mounting blocks holding the cable under test. The witness is comprised of two parts: a top and a bottom rod of similar diameter with the bottom rod having a smaller diameter stem on its upper end and the top rod having a hollow opening in its lower end into which the stem fits forming a witness joint. A small gap is present between the top rod and the larger diameter portion of the bottom rod. A standard extensometer is attached to the top and bottom rods of the witness spanning this small witness gap. When a force is applied to separate the mounting blocks, the gap in the witness expands the same length that the entire test specimen is stretched.

  16. Aerodynamic force coefficients of plain bridge cables in wet conditions

    DEFF Research Database (Denmark)

    Matteoni, Giulia; Georgakis, Christos T.

    In this paper, the aerodynamic forces and force coefficients from preliminary static wind tunnel tests on a plain cable in wet conditions are presented. The presented results are for several different relative cable wind-angles. A comparison is made with tests in dry conditions. In dry conditions...... in the drag coefficient with increasing Reynolds number, accompanied by a near-zero lift coefficient, was observed. A theoretical evaluation of the aerodynamic damping assuming quasi-steady conditions reveals that changes in drag and lift coefficient are nonetheless not sufficient to generate negative...... aerodynamic damping. Analysis of the fluctuating lift component shows the presence of “enhanced” vortex shedding at specific wind velocities – similar to what might be observed in the presence of a tripping wire....

  17. Interaction between Current Imbalance and Magnetization in LHC Cables

    CERN Document Server

    Bottura, L; Kuijper, A; den Ouden, A; ten Haken, B; ten Kate, H H J

    2001-01-01

    The quality of the magnetic field in superconducting accelerator magnets is associated with the properties of the superconducting cable. Current imbalances due to coupling currents DI, as large as 100 A, are induced by spatial variations of the field sweep rate and contact resistances. During injection at a constant field all magnetic field components show a decay behavior. The decay is caused by a diffusion of coupling currents into the whole magnet. This results in a redistribution of the transport current among the strands and causes a demagnetization of the superconducting cable. As soon as the field is ramped up again after the end of injection, the magnetization rapidly recovers from the decay and follows the course of the original hysteresis curve. In order to clarify the interactions between the changes in current and magnetization during injection we performed a number of experiments. A magnetic field with a spatially periodic pattern was applied to a superconducting wire in order to simulate the cou...

  18. Effects of submarine power transmission cables on a glass sponge reef and associated megafaunal community.

    Science.gov (United States)

    Dunham, A; Pegg, J R; Carolsfeld, W; Davies, S; Murfitt, I; Boutillier, J

    2015-06-01

    We examined the effects of submarine power transmission cable installation and operation on glass sponge reef condition and associated megafauna. Video and still imagery were collected using a Remotely Operated Vehicle twice a year for 4 years following cable installation. The effects of cables on glass sponges were assessed by comparing sponge cover along fixed transects and at marked index sites. Megafauna counts along transects were used to explore the effects on associated community. We found no evidence of cable movement across the sponge reef surface. Live sponge cover was found to be consistently lower along cable transects and at cable index sites compared to controls. Live sponge cover was the lowest (55 ± 1.1% decrease) at cable index sites 1.5 years after installation and recovered to 85 ± 30.6% of the original size over the following 2 years. Our data suggest 100% glass sponge mortality along the direct cable footprint and 15% mortality in the surrounding 1.5 m corridor 3.5 years after cable installation. Growth rate of a new glass sponge was 1 and 3 cm/year in first and second year, respectively, and appeared to be seasonal. We observed a diverse megafaunal community with representatives from 7 phyla and 14 classes. Total megafauna, spot prawn, and other Arthropoda abundances were slightly lower along cable transects although the effect of cable presence was not statistically significant. The following measures could be taken to reduce the amount of damage to glass sponge reefs and associated fauna: routing the cable around reefs, whenever possible, minimizing cable movement across the surface of the reef at installation and routine operation, and assessing potential damage to glass sponges prior to decommissioning. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  19. Analytical Solution of Generalized Space-Time Fractional Cable Equation

    OpenAIRE

    Ram K. Saxena; Zivorad Tomovski; Trifce Sandev

    2015-01-01

    In this paper, we consider generalized space-time fractional cable equation in presence of external source. By using the Fourier-Laplace transform we obtain the Green function in terms of infinite series in H-functions. The fractional moments of the fundamental solution are derived and their asymptotic behavior in the short and long time limit is analyzed. Some previously obtained results are compared with those presented in this paper. By using the Bernstein characterization theorem we find ...

  20. Ultra Low Loss Optical Fiber Cable Assemblies. Volume 1.

    Science.gov (United States)

    1983-06-07

    Cable Development Plan The method of investigation followed in leveloping the individual components was to assign each task as a separate and parallel...induce the chemical reaction is supplied by a traversing oxyhydrogen flame applied externally to the tube. After the glass deposition is completed, the...process or separately during an off-line operation. 22 I[ ____.... 3.1.1.3.2.3 Furnace Purge Gas A 50/50 mixture by volume of argon and helium gas is used

  1. Modal analysis of cable-stayed UHPC bridge

    Directory of Open Access Journals (Sweden)

    Tej Petr

    2017-01-01

    Full Text Available This paper deals with the dynamic analysis of cable-stayed UHPC bridge over the Vltava river near town Melnik in Czech Republic, Europe. Bridge serves for pedestrians and cyclists. This work aims to familiarize the reader with dynamic calculations carried out and the results obtained, describing the dynamic properties of proposed bridge. The construction of bridge is designed as a cable-stayed structure with prestressed bridge deck consisting of prefabricated UHPC panels and reversed “V” shaped steel pylon with height of approximately 40 meters. The deck is anchored using 24 steel hangers in one row in a steel pylon - 17 ropes in the main span and 7 cables on the other side. Range of the main span is 99.18 meters and the secondary span is 31.9 m. Deck width is 4.5 meters with 3.0 meters passing space. The bridge is designed for the possibility of passage of vehicles weighting up to 3.5 tonnes. Deck panels are made of UHPC with reinforcement. At the edge of the bridge on the side of the shorter span the bridge deck is firmly connected with abutment and on the other deck it is stored using a pair of sliding bearings.

  2. Unusual Attenuation Recovery Process After Fiber Optic Cable Irradiation

    Science.gov (United States)

    Konečná, Z.; Plaček, V.; Havránek, P.

    2017-11-01

    At present, the number of optical cables in nuclear power plants has been increasing. Fiber optic cables are commonly used at nuclear power plants in instrumentation and control systems but they are usually used in environments without radiation. Nevertheless, currently, the number of applications in NPP containment with radiation is increasing. One of the most prevalent effects of radiation exposure is an increase of signal attenuation (signal loss). This is the result of fiber darkening due to radiation exposure and it is the main limitation factor in application of fiber optics in radiation environment. However, after the irradiation, the fiber optics go through a “recovery process” during which the optical properties improve again; i.e. attenuation decreases. However, we have found cable, where the expected healing process after few days changed its trend and the attenuation increased again to a value well above the attenuation just after the irradiation. This paper describes experiments that were carried out to explain this unusual recovery behaviour.

  3. Structural behavior of suspension bridge with a stabilizing cable

    Directory of Open Access Journals (Sweden)

    Konovalov Anatoliy

    2017-01-01

    Full Text Available Suspended structures are commonly used in construction of motorway and pedestrian bridges. These structures allow wide spans without the need for intermediate supports. Suspension bridges are noted for lower structural stiffness as compared to beam bridges and arc bridges. The stiffness control depending on the environment and external effects (moving loads, wind, seismic forces, etc. is a real-life challenge [1, 2]. The authors of this paper have evaluated the use of stabilizing cable installed in the central span under the stiffening girder as the means of stiffness control. A plane 3D model of a suspension bridge was developed using the ANSYS software. The study compared the stress deformed state and dynamic properties of the models with and without a stabilizing cable. The displacement in the model equipped with a stabilizing cable, as compared to the one without, was noted to be lower in all relevant sections: 2.6 times in the middle of the central span of the stiffening girder; 15 times in the middle of the end span; and displacement of the tower top was 3.5 times lower.

  4. Dynamically Scaled Model Experiment of a Mooring Cable

    Directory of Open Access Journals (Sweden)

    Lars Bergdahl

    2016-01-01

    Full Text Available The dynamic response of mooring cables for marine structures is scale-dependent, and perfect dynamic similitude between full-scale prototypes and small-scale physical model tests is difficult to achieve. The best possible scaling is here sought by means of a specific set of dimensionless parameters, and the model accuracy is also evaluated by two alternative sets of dimensionless parameters. A special feature of the presented experiment is that a chain was scaled to have correct propagation celerity for longitudinal elastic waves, thus providing perfect geometrical and dynamic scaling in vacuum, which is unique. The scaling error due to incorrect Reynolds number seemed to be of minor importance. The 33 m experimental chain could then be considered a scaled 76 mm stud chain with the length 1240 m, i.e., at the length scale of 1:37.6. Due to the correct elastic scale, the physical model was able to reproduce the effect of snatch loads giving rise to tensional shock waves propagating along the cable. The results from the experiment were used to validate the newly developed cable-dynamics code, MooDy, which utilises a discontinuous Galerkin FEM formulation. The validation of MooDy proved to be successful for the presented experiments. The experimental data is made available here for validation of other numerical codes by publishing digitised time series of two of the experiments.

  5. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten

    2001-01-01

    Overcurrents in the power grid can have a magnitude of up to 20 times or higher than the rated current. This may cause problems and permanent damage to electrical equipment in the grid. High temperature superconducting (HTS) tapes are known to be sensitive to currents much larger than their criti......Overcurrents in the power grid can have a magnitude of up to 20 times or higher than the rated current. This may cause problems and permanent damage to electrical equipment in the grid. High temperature superconducting (HTS) tapes are known to be sensitive to currents much larger than...... their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...

  6. High-Density Superconducting Cables for Advanced ACTPol

    Science.gov (United States)

    Pappas, C. G.; Austermann, J.; Beall, J. A.; Duff, S. M.; Gallardo, P. A.; Grace, E.; Henderson, S. W.; Ho, S. P.; Koopman, B. J.; Li, D.; hide

    2016-01-01

    Advanced ACTPol (AdvACT) is an upcoming Atacama Cosmology Telescope (ACT) receiver upgrade, scheduled to deploy in 2016, that will allow measure- ment of the cosmic microwave background polarization and temperature to the highest precision yet with ACT. The AdvACT increase in sensitivity is partly provided by an increase in the number of transition-edge sensors (TESes) per array by up to a factor of two over the current ACTPol receiver detector arrays. The high-density AdvACT TES arrays require 70 µ m pitch superconducting flexible cables (flex) to connect the detec- tor wafer to the first-stage readout electronics. Here, we present the flex fabrication process and test results. For the flex wiring layer, we use a 400-nm-thick sputtered alu- minum film. In the center of the cable, the wiring is supported by a polyimide substrate, which smoothly transitions to a bare (uncoated with polyimide) silicon substrate at the ends of the cable for a robust wedge wire-bonding interface. Tests on the first batch of flex made for the first AdvACT array show that the flex will meet the requirements for AdvACT, with a superconducting critical current above 1 mA at 500 mK, resilience to mechanical and cryogenic stress, and a room temperature yield of 97%.

  7. AC losses of the 5 m BSCCO cables with shield

    Science.gov (United States)

    Ryu, K.; Ma, Y. H.; Li, Z. Y.; Hwang, S. D.; Song, H. J.

    2010-11-01

    In order to research the AC loss characteristics of a multi-layered conductor and a shield in a high temperature superconductor (HTS) cable, we prepared two short cable samples, which are the same as the 22.9 kV/50 MVA HTS-cable installed at Gochang test yard of Korea Electric Power Corporation, and attached voltage-leads to both the conductor and the shield. To investigate the effect of transport period on their AC losses, we also applied current with the same magnitude and opposite direction to the conductor and the shield from a few cycles to several minutes. The tests show that the AC loss measured from the lead attached to the shield (shield-lead) is constant regardless of transport period. But the measured loss from the lead attached to the conductor (conductor-lead) is greatly dependent on transport period. It seems to be caused by difficulty in heat transfer to the surrounding coolant due to thick insulator around the conductor. As transport period becomes longer, the conductor's temperature rises and thus the AC loss measured from the conductor-lead increases. In addition, the measured loss from the conductor-lead is 1.5 times larger than that from the shield-lead, particularly for the transport period of a few cycles.

  8. Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, Kevin L.; Fifield, Leonard S.; Westman, Matthew P.; Ramuhalli, Pradeep; Pardini, Allan F.; Tedeschi, Jonathan R.; Jones, Anthony M.

    2013-09-27

    The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early

  9. Energy cables: defects pre-localization by echo-metry; Cables d'energie: prelocalisation des defauts par echometrie

    Energy Technology Data Exchange (ETDEWEB)

    Kuzyk, H. [Electricite de France (EDF), 75 - Paris (France)

    2006-05-15

    Echo-metric methods, based on the analysis of a cable response to an electromagnetic pulse, allow the pre-localization of defects. The precise localization is performed with a shock wave generator. This article describes the different echo-metric methods: 1 - low voltage pulse echo-metric methods: classical method, arc reflection method; 2 - current pulse echo-metric methods: direct voltage method, comparison methods, direct shock method, differential comparison method. (J.S.)

  10. A wireless smart sensor network for automated monitoring of cable tension

    Science.gov (United States)

    Sim, Sung-Han; Li, Jian; Jo, Hongki; Park, Jong-Woong; Cho, Soojin; Spencer, Billie F., Jr.; Jung, Hyung-Jo

    2014-02-01

    As cables are primary load carrying members in cable-stayed bridges, monitoring the tension forces of the cables provides valuable information regarding structural soundness. Incorporating wireless smart sensors with vibration-based tension estimation methods provides an efficient means of autonomous long-term monitoring of cable tensions. This study develops a wireless cable tension monitoring system using MEMSIC’s Imote2 smart sensors. The monitoring system features autonomous operation, sustainable energy harvesting and power consumption, and remote access using the internet. To obtain the tension force, an in-network data processing strategy associated with the vibration-based tension estimation method is implemented on the Imote2-based sensor network, significantly reducing the wireless data transmission and the power consumption. The proposed monitoring system has been deployed and validated on the Jindo Bridge, a cable-stayed bridge located in South Korea.

  11. Application of Microwave Remote Sensing to Dynamic Testing of Stay-Cables

    Directory of Open Access Journals (Sweden)

    Carmelo Gentile

    2009-12-01

    Full Text Available Recent advances in radar techniques and systems have favoured the development of microwave interferometers, suitable for the non-contact vibration monitoring of large structures. The paper addresses the application of microwave remote sensing to the measurement of the vibration response in the stay-cables of cable-stayed bridges. The reliability and accuracy of the proposed technique were investigated by comparing the natural frequencies (and the cable tensions predicted from natural frequencies identified from radar data and the corresponding quantities obtained using more conventional techniques. The investigation, carried out on the cables of two different cable-stayed bridges, clearly highlights: (a the accuracy of the results provided by the microwave remote sensing; (b the simplicity of use of the radar technique (especially when compared with conventional approaches and its effectiveness to simultaneously measuring the dynamic response of all the stay-cables of an array.

  12. A construction and a tension element comprising a cable and one or more strakes

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a construction comprising a structural element and at least one cable (101) arranged in tension to carry at least a part of the weight of the structural element. The cable defines an outer surface (102) onto which at least one strake (104) forms a protrusion for reducing rain...... and wind induced vibrations. The strake has a height being a distance from a strake root part connected to the outer surface of the cable and a strake end part terminating the strake outwards away from the cable, and the strake has a width being transverse to the height, the width decreasing...... in the direction from the strake root part towards the strake end part. The height is less than 5 percent of the diameter of the cable. Furthermore, the strake comprises a first strake surface portion facing away from the cable, which first strake surface portion is concave or straight....

  13. A construction and a tension element comprising a cable and a plurality of strakes

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a construction comprising a structural element and at least one cable (100) arranged in tension to carry at least a part of the weight of the structural element. The cable defines an outer surface (102) onto which a plurality of strakes (104) form protrusions for reducing...... rain and wind induced vibrations. Each strake has a height being a distance from a strake root part connected to the outer surface of the cable and a strake end part terminating the strake outwards form the cable, a width being transverse to the height, and a length transverse to the height and width...... and along which length the strake is connected to the cable. The length of each strake is shorter than the circumference of the outer surface, and the height is less than 5 percent of the diameter of the cable....

  14. Aerodynamic coefficients of stationary dry inclined bridge cables in laminar flow

    DEFF Research Database (Denmark)

    Matteoni, Giulia; Georgakis, Christos; Ricciardelli, Francesco

    2011-01-01

    Stay cables are the most flexible elements of cable-stayed bridges. When exposed to wind loading, they often undergo large amplitude vibrations, thus motivating serious design concerns. In most cases, vibrations are observed in the presence of water rivulets or ice accretions, which lead to an ef......Stay cables are the most flexible elements of cable-stayed bridges. When exposed to wind loading, they often undergo large amplitude vibrations, thus motivating serious design concerns. In most cases, vibrations are observed in the presence of water rivulets or ice accretions, which lead...... experimental and theoretical research in the last two decades, even though a definitive understanding of the flow around inclined cables under various surface conditions has not been achieved. A comparative study on the aerodynamic coefficients of stationary inclined stay cables, under various surface...

  15. Workers in the VAB remove cable covers from STS-98 SRB's for inspection

    Science.gov (United States)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- Near the bottom of the solid rocket booster, a worker in the Vehicle Assembly Building begins to detach the SRB system tunnel cover on the 36 cables inside. The SRB is part of Space Shuttle Atlantis, rolled back from Launch Pad 39A in order to conduct tests on the cables. A prior extensive evaluation of NASA'''s SRB cable inventory on the shelf revealed conductor damage in four (of about 200) cables. Shuttle managers decided to prove the integrity of the system tunnel cables already on Atlantis before launching. Workers are conducting inspections, making continuity checks and conducting X-ray analysis on the cables. The launch has been rescheduled no earlier than Feb. 6.

  16. INFLUENCE OF CONSTRUCTIVE AND TECHNOLOGICAL DEFECTS ON COAXIAL RADIO-FREQUENCY CABLE IMPEDANCE

    Directory of Open Access Journals (Sweden)

    G.V. Bezprozvannych

    2013-04-01

    Full Text Available Coaxial user's radio-frequency cables belong to a category of cable television network elements parameters of which essentially specify the system capabilities as a whole. The cable working frequency spectrum spreading to 1000 MHz along with digital television and soundtrack signals transmission and high-definition television introduction causes more rigid requirements for wave impedance and, consequently, for the cable design. The established norms on user's cable impedance deviations fail to answer the state-of-the-art requirements for granting a complex of interactive services. On the basis of calculations performed, values of internal and external conductor diameters deviations as well as dielectric permeability of the insulation material are validated. For up-to-date user's radio-frequency cables, the impedance deviation from the normalized average value of 75 Ohm should not exceed ± 2 Ohm.

  17. Error Correction of EMTDC Line and Cable Series Impedance Calculations Compared to Traditional Methods

    DEFF Research Database (Denmark)

    Sørensen, Stefan; Nielsen, Hans Ove

    2002-01-01

    In this paper we present comparison of different line and cable series impedance calculation methods, where the correction of a discovered PSCAD/EMIDC v.3.0.8 calculation error of the cable series impedance results n deviation under 0.1% instead of the previous method which gave approximately 10%......% deviation to other methods. The correction is done by adjusting he earth return path impedance for the cable model, and will thereby form the basis for a future comparison with measured data from a real full scale earth fault experiment on a mixed line and cable network.......In this paper we present comparison of different line and cable series impedance calculation methods, where the correction of a discovered PSCAD/EMIDC v.3.0.8 calculation error of the cable series impedance results n deviation under 0.1% instead of the previous method which gave approximately 10...

  18. Fabrication and performance of $Nb_{3}Sn$ Rutherford-type cable with Cu added as a separate component

    CERN Document Server

    Coccoli, M; Calvi, M; Caspi, S; Chiesa, L; Hafalia, R R; Higley, H C; Dietderich, D R; Gourlay, S A; Lietzke, A F; McInturff, A D; Sabbi, G L

    2004-01-01

    From the standpoint of overall conductor cost, it is desirable to minimize the amount of Cu that is co-processed with the superconductor during strand fabrication. We are investigating several approaches for fabricating multistrand cables in which the Cu is added at the final, i.e. cabling, stage of manufacture. These include mixed strand Rutherford-type cables with pure Cu strands cabled together with superconductor strands that have a low volume fraction of Cu, Cu added as a core to a Rutherford-type cable, and Cu strip added to the surface of the cable. Results on fabrication of several alternate types of Nb3Sn cables are presented. The more promising types of mixed strand and cored cables are being evaluated in short sample and small magnet tests. These results will be presented and the performance will be compared with conventional Rutherford cables where the Cu is an integral component of the superconductor strand.

  19. Biomechanical cadaveric comparison of patellar ligament suture protected by a steel cable versus a synthetic cable.

    Science.gov (United States)

    Bouget, P; Breque, C; Beranger, J S; Faure, J P; Khiami, F; Vendeuvre, T

    2017-12-01

    Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. There is no significant difference in protection of the ligament suture between the "terylene" and "steel" groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of

  20. Development of the Nb3Sn Rutherford Cable for the EuCARD High Field Dipole Magnet FRESCA2

    CERN Document Server

    Oberli, l

    2013-01-01

    This paper reports on the development of the Nb3Sn Rutherford cable for the EuCARD high field dipole magnet FRESCA2 designed to achieve a central field of 13 T at 4.2 K in a 100 mm bore. The FRESCA2 cable is rectangular and made of 40 strands of 1.0 mm diameter. The cable shall be able to carry a current of 15.7 kA at 4.2 K in a field of 15 T. In the first stage of cable development, focus was put on the cable parameters (cable width, cable mid-thickness and pitch length) to provide a cable made with Nb3Sn PIT strands achieving both a minimal critical current reduction of the strand during cabling and a good mechanical stability of the cable for coil winding. In the second stage of cable development, the cable was produced with Nb3Sn RRP strands. The cables, which were produced following an iterative process, were characterized and the results of the critical current measurements of extracted strands are discussed together with the cabling parameters and the type of strand.

  1. Effect of oxygen concentration on fire growth of various types of cable bending in horizontal and vertical orientations

    Science.gov (United States)

    Pangaribuan, Adrianus; Dhiputra, I. M. K.; Nugroho, Yulianto S.

    2017-03-01

    Electrical cable is a whole of the material including metal (cooper) conductor and its insulation, when an electrical cable is flowed by electric current, based on its own capacity, the temperature of cable conductor increases gradually. If the current flows above the cable carrying capacity, then an extreme temperature rises are expected. When temperature increase, the electric current flow inside cable conductor will decrease gradually related to the resistance and could occur repeatedly in a period. Since electrical faults on electrical cable system are often suspected as the cause of fires, thus this research aims to investigate measures of preventing the fire to start by means of controlling oxygen concentration in a cable compartment. The experimental work was conducted in laboratory by using electrical power cable of 1.5 mm2 size. Two transparent chambers were applied for studying the effect of vertical and horizontal orientations on the cable temperature rise, under various oxygen concentration of the gas streams. In the present work, the electrical was maintained at a constant level during a typical test run. Parametric studies reported in the paper include the use of a bare and insulated cables as well as the bending shape of the cable lines of a straight cable, coiled cable and randomly bent cable which were loaded with the same electric load and oxygen concentration in the gas supply.

  2. Tests of industrial ethylene-propylene rubber high voltage cable for cryogenic use

    CERN Document Server

    Balhan, B; Goddard, B; Muratori, G; Otwinowski, S; Rieubland, Jean Michel; Wang, H; CERN. Geneva. SPS and LEP Division

    1999-01-01

    At the beginning of 1999 UCLA has received a prototype High Voltage Cryogenic Cable supplied fee of charge by Pirelli. The cable is intended for more than ten years of service at 100 kV D.C. and liquid argon temperature. Thecable uses an all welded construction, whichi is axially tight and free of ionizable voids. The cable was submitted to a number of mechanical and electrical tests as described below.

  3. Status Report and Research Plan for Cables Harvested from Crystal River Unit 3 Nuclear Generating Plant

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-20

    Harvested cables from operating or decommissioned nuclear power plants present an important opportunity to validate models, understanding material aging behavior, and validate characterization techniques. Crystal River Unit 3 Nuclear Generating Plant is a pressurized water reactor that was licensed to operate from 1976 to 2013. Cable segments were harvested and made available to the Light Water Reactor Sustainability research program through the Electric Power Research Institute. Information on the locations and circuits within the reactor from whence the cable segments came, cable construction, sourcing and installation information, and photographs of the cable locations prior to harvesting were provided. The cable variations provided represent six of the ten most common cable insulations in the nuclear industry and experienced service usage for periods from 15 to 42 years. Subsequently, these cables constitute a valuable asset for research to understand aging behavior and measurement of nuclear cables. Received cables harvested from Crystal River Unit 3 Nuclear Generating Plant consist of low voltage, insulated conductor surrounded by jackets in lengths from 24 to 100 feet each. Cable materials will primarily be used to investigate aging under simultaneous thermal and gamma radiation exposure. Each cable insulation and jacket material will be characterized in its as-received condition, including determination of the temperatures associated with endothermic transitions in the material using differential scanning calorimetry and dynamic mechanical analysis. Temperatures for additional thermal exposure aging will be selected following the thermal analysis to avoid transitions in accelerated laboratory aging that do not occur in field conditions. Aging temperatures above thermal transitions may also be targeted to investigate the potential for artifacts in lifetime prediction from rapid accelerated aging. Total gamma doses and dose rates targeted for each material

  4. Lateral Vibrations of a Cable-Stayed Bridge under Crowd Excitation

    OpenAIRE

    Lijun Ouyang; Caihong Wang; Bin Zhen; Jian Xu

    2015-01-01

    A cable-stayed bridge model under crowd excitation is established in this paper by considering the geometric nonlinear property of the cables. Lateral vibrations of the model are investigated by employing the center manifold theory, and the first-order approximation solution of the periodic vibration of the bridge is derived by using the energy method. Numerical simulations are carried out to verify the validity of our analytical expressions. Our research shows that the existence of the cable...

  5. Online fault location on AC cables in underground transmission systems using screen currents

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Nanayakkara, O.M.K.K; Rajapakse, Athula

    . At 31.4 km, all cables were accessible which made it possible to apply a fault using an arc free breaker and measure the travelling waves at each end of the cable. On a crossbonded cable system, the sheath is short circuited and grounded at both ends. This makes possible the use of low voltage Rogowski...... and simulations are compared for testing the reliability of using simulations for studying fault location methods....

  6. Online Fault Location on AC Cables in Underground Transmission Systems using Sheath Currents

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Nanayakkarab, Kasun; Rajapakse, Athula

    2014-01-01

    . At 31.4 km, all cables were accessible which made it possible to apply a fault using an arc free breaker and measure the travelling waves at each end of the cable. On a crossbonded cable system, the sheaths are short circuited and grounded at both ends. This makes possible the use of low voltage...... measurements and simulations are compared for testing the reliability of using simulations for studying fault location methods....

  7. State of the art analysis of online fault location on AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Gudmundsdottir, Unnur Stella; Bak, Claus Leth

    2011-01-01

    In this article the state of the art research for online fault location on cross-bonded transmission level cables is presented. The article is focused on the difficulties in using the algorithms developed for OHL-systems and distribution cables directly on cross-bonded transmission cables....... Impedance based methods, methods based on solving the line differential equations, methods based on traveling wave methods and methods based on artificial intelligence networks are presented and discussed....

  8. Ground return effect on wave propagation parameters of overhead power cables

    Energy Technology Data Exchange (ETDEWEB)

    Malo Machado, V.M.; Brandao Faria, J.A.; Borges da Silva, J.F. (Centro de Electrotecnia da Univ. Tecnia de Lisboa, Inst. Superior Tecnico, Dept. of Electrical Engineering, 1096 Lisboa Codex (PT))

    1990-04-01

    The propagation properties of overhead three-phase cables are usually analyzed assuming that the pipe conductor establishes a perfect shielding between the inner conductor set and any outer conductor, i.e., the power cable is assumed as an isolated system. The influence of a lossy ground plane in the neighborhood of the cable is examined in this paper. The propagation parameters for both approaches are compared---significative differences being found to exist, in the zero mode, at low working frequencies.

  9. Development, characteristics and comparative structural analysis of tensegrity type cable domes

    National Research Council Canada - National Science Library

    Nenadović Aleksandra

    2010-01-01

    Tensegrity type cable domes are three-dimensional structural configurations, prestressed inside the perimeter compression ring, in which the continuous tension throughout the roof structure is made...

  10. Electromagnetic coupling into two standard calibration shields on the Sandia cable tester

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Basilio, Lorena I.; Langston, William L.; Chen, Kenneth C.; Hudson, Howard Gerald; Morris, M. E.; Stronach, S.L.; Johnson, W. A.; Derr, W.

    2014-02-01

    This report presents analytic transmission line models for calculating the shielding effectiveness of two common calibration standard cables. The two cables have different canonical aperture types, which produce the same low frequency coupling but different responses at resonance. The dominant damping mechanism is produced by the current probe loads at the ends of the cables, which are characterized through adaptor measurements. The model predictions for the cables are compared with experimental measurements and good agreement between the results is demonstrated. This setup constitutes a nice repeatable geometry that nevertheless exhibits some of the challenges involved in modeling non-radio frequency geometries.

  11. Out-of-plane free vibration analysis of a cable-arch structure

    Science.gov (United States)

    Kang, H. J.; Zhao, Y. Y.; Zhu, H. P.

    2013-02-01

    Cable-arch structure has been widely used in many long-span structures such as cable roofs and cable-stayed arch bridges, but its dynamics is still not well understood. In this paper, the out-of-plane dynamic behavior of a cable-arch structure is investigated. The equations governing the out-of-plane free vibration of the structure are derived using d'Alembert's principle. A transfer matrix method is used to solve the governing equations and determine the frequencies of the out-of-plane vibration. The theories are then used to study two specific cases: free vibration of a model cable-arch and simulation of an arch erection process. The effects of some key parameters of cable and arch, such as tension of cable and radius, open-angle and shape of arch, are examined. The results indicate that in-plane and spatial cables can largely improve the out-of-plane dynamic behavior of arch structures, which are further verified by analyzing the out-of-plane buckling of cable-arch structures. The present work should be valuable and significant not only for the fundamental research but also engineering design of roofs and bridges.

  12. Modeling and analysis of the in-plane vibration of a complex cable-stayed bridge

    Science.gov (United States)

    Cao, D. Q.; Song, M. T.; Zhu, W. D.; Tucker, R. W.; Wang, C. H.-T.

    2012-12-01

    The in-plane vibration of a complex cable-stayed bridge that consists of a simply-supported four-cable-stayed deck beam and two rigid towers is studied. The nonlinear and linear partial differential equations that govern transverse and longitudinal vibrations of the cables and transverse vibrations of segments of the deck beam, respectively, are derived, along with their boundary and matching conditions. The undamped natural frequencies and mode shapes of the linearized model of the cable-stayed bridge are determined, and orthogonality relations of the mode shapes are established. Numerical analysis of the natural frequencies and mode shapes of the cable-stayed bridge is conducted for various symmetrical and non-symmetrical bridge cases with regards to the sizes of the components of the bridge and the initial sags of the cables. The results show that there are very close natural frequencies when the bridge model is symmetrical and/or partially symmetrical, and the mode shapes tend to be more localized when the bridge model is less symmetrical. The relationships between the natural frequencies and mode shapes of the cable-stayed bridge and those of a single fixed-fixed cable and the single simply-supported deck beam are analyzed. The results, which are validated by commercial finite element software, demonstrate some complex classical resonance behavior of the cable-stayed bridge.

  13. Seismic Fragility Assessment of an Isolated Multipylon Cable-Stayed Bridge Using Shaking Table Tests

    Directory of Open Access Journals (Sweden)

    Yutao Pang

    2017-01-01

    Full Text Available In recent decades, cable-stayed bridges have been widely built around the world due to the appealing aesthetics and efficient and fast mode of construction. Numerous studies have concluded that the cable-stayed bridges are sensitive to earthquakes because they possess low damping characteristics and high flexibility. Moreover, cable-stayed bridges need to warrant operability especially in the moderate-to-severe earthquakes. The provisions implemented in the seismic codes allow obtaining adequate seismic performance for the cable-stayed bridge components; nevertheless, they do not provide definite yet reliable rules to protect the bridge. To date, very few experimental tests have been carried out on the seismic fragility analysis of cable-stayed bridges which is the basis of performance-based analyses. The present paper is aimed at proposing a method to derive the seismic fragility curves of multipylon cable-stayed bridge through shake table tests. Toward this aim, a 1/20 scale three-dimensional model of a 22.5 m cable-stayed bridge in China is constructed and tested dynamically by using the shaking table facility of Tongji University. The cable-stayed bridge contains three pylons and one side pier. The outcomes of the comprehensive shaking table tests carried out on cable-stayed bridge have been utilized to derive fragility curves based on a systemic approach.

  14. Novel cable coupling technique for improved shallow distributed acoustic sensor VSPs

    Science.gov (United States)

    Munn, Jonathan D.; Coleman, Thomas I.; Parker, Beth L.; Mondanos, Michael J.; Chalari, Athena

    2017-03-01

    Vertical seismic profiles (VSPs) collected using fiber optic distributed acoustic sensors (DAS) are becoming increasingly common; yet, ensuring good cable coupling with the borehole wall remains a persistent challenge. Traditional cable deployment techniques used in the petroleum industry are either not possible or do not provide data of sufficient quality for shallow applications. Additionally, no direct field comparison of coupling techniques in the same borehole exists to determine the impacts of poor coupling on DAS VSP data quality. This paper addresses these issues by: (1) presenting a novel cable coupling solution using a removable and relatively inexpensive FLUTe™ flexible borehole liner; and (2) presenting field examples of DAS VSPs under different coupling conditions. The proposed coupling technique is analogous to a fully cemented deployment in that the cable is continuously coupled directly to the formation. Field experiments conducted to assess and validate the technique demonstrate a marked improvement in VSP data quality when the cable is coupled with a flexible borehole liner. Without the liner, seismic profiles are dominated by a high-amplitude cable wave and the p-wave arrival is not observed; however, with cable coupling provided by a borehole liner inflated using hydrostatic pressure, the cable wave is suppressed and clear p-wave arrivals are visible. Additional tests examining the influence of fiber optic cable structure on seismic responses demonstrate that tight buffered fibers are more sensitive to dynamic strain than loose tube fibers making them potentially better suited for certain DAS applications.

  15. On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy

    Science.gov (United States)

    Chen, Zhe; Agostinelli, Alfred; Nath, Ravinder

    1998-03-01

    The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to ). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated that an additional error of up to 4% could be introduced if the unshielded cable's spatial

  16. Structural Health Monitoring approach for detecting ice accretion on bridge cable using the Haar Wavelet Transform

    DEFF Research Database (Denmark)

    Andre, Julia; Kiremidjian, Anne; Liao, Yizheng

    2016-01-01

    of the structure. In this paper, an ice accretion detection algorithm is presented based on the Continuous Wavelet Transform (CWT). In the proposed algorithm, the acceleration signals obtained from bridge cables are transformed using wavelet method. The damage sensitive features (DSFs) are de fined as a function...... of the wavelet energy at specific wavelet scales. It is found that as ice accretes on the cables, the mass of cable increases, thus changing the wavelet energies. Hence, the DSFs can be used to track the change of cables mass. To validate the proposed algorithm, we use the data collected from a laboratory...

  17. A full 3D time-dependent electromagnetic model for Roebel cables

    DEFF Research Database (Denmark)

    Rodriguez Zermeno, Victor Manuel; Grilli, Francesco; Sirois, Frederic

    2013-01-01

    current sharing among them. However, since Roebel cables have a true 3D structure and are made of several high aspect ratio coated conductors, modelling and simulation of their electromagnetic properties is very challenging. Therefore, a realistic model taking into account the actual layout of the cable...... is unavoidably a large scale computational problem. In this work, we present a full 3D model of a Roebel cable with 14 strands. The model is based on the H-formulation, widely used for 2D problems. In order to keep the 3D features of the cable (in particular the magnetization currents near the transpositions...

  18. Simplified frequency-dependent formulae for series-impedance matrices of single-core HVAC cables

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da

    2015-01-01

    The installation of HVAC underground cables became more common in recent years, a trend expected to continue in the future. Underground cables are more complex than overhead lines and the calculation of their resistance and reactance can be challenging and time consuming for frequencies that are ......The installation of HVAC underground cables became more common in recent years, a trend expected to continue in the future. Underground cables are more complex than overhead lines and the calculation of their resistance and reactance can be challenging and time consuming for frequencies...

  19. Geometrical Configuration of Cabling as Factor Influencing the Reproducibility of EMC Immunity Tests

    Directory of Open Access Journals (Sweden)

    I. Szolik

    2006-12-01

    Full Text Available The paper deals with analysis of the influence of geometrical configuration of device cabling upon voltages induced in cable interfaces. The analyzed properties are the cable height and the cable length for common mode disturbance, and the loop width for differential mode disturbance. The analysis is solved both by analytical calculation and by numerical simulation. Achieved results are compared mutually as well as with results obtained by measurements performed according to standardized procedures. Finally the analyzed parameters are ordered in correspondence of their importance for objectivity and reproducibility of immunity tests against electromagnetic field.

  20. Fiscal 1997 report on the results of the international standardization R and D. Development of a test method of halogen-free flame-retardant cables and a study of the cable standards; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Non halogen nannen cable no shiken hoho kaihatsu narabini cable kikaku no kento

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    As for halogen-free flame-retardant cables with high recyclability and safety (HFFR cables), the development is being promoted in many countries as a next generation cable. The standard of HFFR cables has been set up by some countries and groups in the U.S. and Europe, but the international standard has not yet been established independently. The purpose of this R and D is the development of a test method to appropriately evaluate the performance of HFFR cables and its standardization, and the proposal of the international standardization on common items of the cable standard. A study group was sent to the U.S. and Europe to investigate the development, application status and test methods of the HFFR cable overseas. The ion chromatography and FT-IR method were studied as methods to evaluate corrosivity/toxicity of the gases emitted in combustion. The performance of HFFR cables in Japan and abroad was also evaluated mainly by IEC standards. Further, considering the results of the overseas surveys, the structure and details of the international standard plan on HFFR cables were studied, and approaches to the international standardization were studied. 32 refs., 31 figs., 54 tabs.

  1. Lightning insulation coordination for a +600kV dc gas insulated cable

    Energy Technology Data Exchange (ETDEWEB)

    Hileman, A.R.; Flugman, R.W.; Garrity, T.F.; Main, C.T.

    1982-11-01

    To determine the required BIL of a +600 kV dc gas-insulated cable, a probabilistic insulation coordination study was performed. An equation was developed to determine the maximum voltage on the cable as a function of directly connected highly nonlinear surge protective devices (MO). After estimating the distribution of surge voltage magnitudes and shapes which arrive at the line-cable junction, the probability of flashover within the cable was determined. The results, analyzed in terms of mean time between failures, MTBF, verified that a 1300 kV BIL was adequate.

  2. What threat do turbidity currents and submarine landslides pose to submarine telecommunications cable infrastructure?

    Science.gov (United States)

    Clare, Michael; Pope, Edward; Talling, Peter; Hunt, James; Carter, Lionel

    2016-04-01

    The global economy relies on uninterrupted usage of a network of telecommunication cables on the seafloor. These submarine cables carry ~99% of all trans-oceanic digital data and voice communications traffic worldwide, as they have far greater bandwidth than satellites. Over 9 million SWIFT banks transfers alone were made using these cables in 2004, totalling 7.4 trillion of transactions per day between 208 countries, which grew to 15 million SWIFT bank transactions last year. We outline the challenge of why, how often, and where seafloor cables are broken by natural causes; primarily subsea landslides and sediment flows (turbidity currents and also debris flows and hyperpycnal flows). These slides and flows can be very destructive. As an example, a sediment flow in 1929 travelled up to 19 m/s and broke 11 cables in the NE Atlantic, running out for ~800 km to the abyssal ocean. The 2006 Pingtung earthquake triggered a sediment flow that broke 22 cables offshore Taiwan over a distance of 450 km. Here, we present initial results from the first statistical analysis of a global database of cable breaks and causes. We first investigate the controls on frequency of submarine cable breaks in different environmental and geological settings worldwide. We assess which types of earthquake pose a significant threat to submarine cable networks. Meteorological events, such as hurricanes and typhoons, pose a significant threat to submarine cable networks, so we also discuss the potential impacts of future climate change on the frequency of such hazards. We then go on to ask what are the physical impacts of submarine sediment flows on submerged cables? A striking observation from past cable breaks is sometimes cables remain unbroken, whilst adjacent cables are severed (and record powerful flows travelling at up to 6 m/s). Why are some cables broken, but neighbouring cables remain intact? We provide some explanations for this question, and outline the need for future in

  3. Cryogenic and Electrical Test Results of 30 M Hts Power Cable

    Science.gov (United States)

    Sytnikov, V. E.; Vysotsky, V. S.; Fetisov, S. S.; Nosov, A. A.; Shakaryan, Yu. G.; Kochkin, V. I.; Kiselev, A. N.; Terentyev, Yu. A.; Patrikeev, V. M.; Zubko, V. V.

    2010-04-01

    In the framework of the Russian R&D Program for HTS power devices, 3×30 m cable with operating current of ˜1.5-2 kA and operating voltage of 20 kV was delivered by Russian Scientific R&D Cable Institute as the first stage of the HTS power cables project. Different basic HTS materials, cryostats and current leads were used for the cable design in this essentially research part of the project. The cable is being tested at special test facility for superconducting power devices developed at the R&D Center for Power Engineering. The cryogenic system for the test facility was provided by Stirling. The basic cryogenic system was equipped with a specially developed flow distribution unit. This unit permits variation and control of liquid nitrogen flows, pressures and temperatures in all three cable phases. Dependencies on temperature of critical currents of each phase were measured during cable tests. The results of the project]s first stage were used to develop and produce a 3×200 m cable system for Moscow distribution grid. In the paper results of cryogenic system tests and cable electrical tests are presented.

  4. Nonlinear observer design for a nonlinear string/cable FEM model using contraction theory

    DEFF Research Database (Denmark)

    Turkyilmaz, Yilmaz; Jouffroy, Jerome; Egeland, Olav

    model is presented in the form of partial differential equations (PDE). Galerkin's method is then applied to obtain a set of ordinary differential equations such that the cable model is approximated by a FEM model. Based on the FEM model, a nonlinear observer is designed to estimate the cable......Contraction theory is a recently developed nonlinear analysis tool which may be useful for solving a variety of nonlinear control problems. In this paper, using Contraction theory, a nonlinear observer is designed for a general nonlinear cable/string FEM (Finite Element Method) model. The cable...

  5. Efficiency of using cables on 6-110 kV with sticked polyethylene isolation

    Directory of Open Access Journals (Sweden)

    Korotkevich Michail

    2017-01-01

    Full Text Available The expediency of using more expensive 6-10 kV cables with XLPE insulation was proved by us on the basis of the method of multi-purpose optimization, which took into account both the resulted costs for the construction and operation of cable lines, and the reliability of its operation, as well as the convenience of installation. Without compensation of capacitive currents, permissible difference in the height of the cable laying, the effect of cable lines on the environment.

  6. Characterization of Nb3Sn Rutherford cables for the LHC 11-T Dipole Magnet

    CERN Document Server

    Wuis, A J; Ballarino, A; Oberli, L; Ten Kate, H H J

    2013-01-01

    The so-called CERN-LHC DS upgrade relies on the use of 11 T dipole magnets. For these magnets 40 strands Nb3Sn type Rutherford cables based on 0.7 mm wires are being developed. Recently four samples of the cables were characterized in the CERN FRESCA cable test station. The critical current and the premature quench current due to magneto-thermal instability were measured at 1.9 K and 4.3 K in a background magnetic field between 0 and 9.6 T (the peak magnetic field on the conductor, including the self-field of the cable, ranges from ~ 2 T to ~ 12 T). Two cable samples were based on Powder-In-Tube (PIT) wire and two on Restacked-Rod-Process (RRP) wire. The PIT samples were identical and without a core in the cable while one of the RRP samples features a 25 μm thick stainless steel core. All cables samples tested have a width and a thickness of about 14.7 mm and 1.25 mm, respectively. Cables and sample holders were manufactured at CERN. In this paper we report and discuss the cable test results and compare them...

  7. Response of Nuclear Power Plant Instrumentation Cables Exposed to Fire Conditions.

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    This report presents the results of instrumentation cable tests sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research and performed at Sandia National Laboratories (SNL). The goal of the tests was to assess thermal and electrical response behavior under fire-exposure conditions for instrumentation cables and circuits. The test objective was to assess how severe radiant heating conditions surrounding an instrumentation cable affect current or voltage signals in an instrumentation circuit. A total of thirty-nine small-scale tests were conducted. Ten different instrumentation cables were tested, ranging from one conductor to eight-twisted pairs. Because the focus of the tests was thermoset (TS) cables, only two of the ten cables had thermoplastic (TP) insulation and jacket material and the remaining eight cables were one of three different TS insulation and jacket material. Two instrumentation cables from previous cable fire testing were included, one TS and one TP. Three test circuits were used to simulate instrumentation circuits present in nuclear power plants: a 4–20 mA current loop, a 10–50 mA current loop and a 1–5 VDC voltage loop. A regression analysis was conducted to determine key variables affecting signal leakage time.

  8. Assessing potential impacts of energized submarine power cables on crab harvests

    Science.gov (United States)

    Love, Milton S.; Nishimoto, Mary M.; Clark, Scott; McCrea, Merit; Bull, Ann Scarborough

    2017-12-01

    Offshore renewable energy facilities transmit electricity to shore through submarine power cables. Electromagnetic field emissions (EMFs) are generated from the transmission of electricity through these cables, such as the AC inter-array (between unit) and AC export (to shore) cables often used in offshore energy production. The EMF has both an electric component and a magnetic component. While sheathing can block the direct electric field, the magnetic field is not blocked. A concern raised by fishermen on the Pacific Coast of North America is that commercially important Dungeness crab (Metacarcinus magister Dana, 1852)) might not cross over an energized submarine power cable to enter a baited crab trap, thus potentially reducing their catch. The presence of operating energized cables off southern California and in Puget Sound (cables that are comparable to those within the arrays of existing offshore wind energy devices) allowed us to conduct experiments on how energized power cables might affect the harvesting of both M. magister and another commercially important crab species, Cancer productus Randall, 1839. In this study we tested the questions: 1) Is the catchability of crabs reduced if these animals must traverse an energized power cable to enter a trap and 2) if crabs preferentially do not cross an energized cable, is it the cable structure or the EMF emitted from that cable that deters crabs from crossing? In field experiments off southern California and in Puget Sound, crabs were given a choice of walking over an energized power cable to a baited trap or walking directly away from that cable to a second baited trap. Based on our research we found no evidence that the EMF emitted by energized submarine power cables influenced the catchability of these two species of commercially important crabs. In addition, there was no difference in the crabs' responses to lightly buried versus unburied cables. We did observe that, regardless of the position of the cable

  9. Analysis of FCL effect caused by superconducting DC cables for railway systems

    Science.gov (United States)

    Nishihara, Taichi; Hoshino, Tsutomu; Tomita, Masaru

    2017-02-01

    DC superconducting cable that is expected for railway system has been developed in the world, since the introduction effects were expected to energy saving. However, behaviour under unsteady states such as a short circuit accident are not entirely clear, and appropriate method of protection has not been established. Therefore, simulation model of the superconducting cable under direct current system was built and analyzed. Analysis result suggests the superconducting cable has the effect of Fault Current Limited (FCL) and critical current rise was effective method for temperature-rise suppression under unsteady states. Trade-off between cable temperature rise and overcurrent was confirmed.

  10. Offshore Wind Farm Cable Connection Configuration Optimization using Dynamic Minimum Spanning Tree Algorithm

    DEFF Research Database (Denmark)

    Hou, Peng; Hu, Weihao; Chen, Zhe

    2015-01-01

    Anew approach, Dynamic Minimal Spanning Tree (DMST) algorithm, whichisbased on the MST algorithm isproposed in this paper to optimizethe cable connectionlayout for large scale offshore wind farm collection system. The current carrying capacity of the cable is considered as the main constraint....... Thedynamic changing of the cable capacity, therefore, the cost during the searching process is presented in this work. Twowind farms arechosen as the studied case and the final results showthat the proposed methodcan save the investment on cables 1.07% and 6.10% respectively compared with MST method...

  11. External electromagnetic transient sources: analysis of its effect in underground power cables; Fuentes transitorias electromagneticas externas: analisis de su efecto en los cables de potencia subterraneos

    Energy Technology Data Exchange (ETDEWEB)

    Escamilla Paz, Antonio

    2009-07-01

    In most of the electrical power systems that operate at present, the subterranean cables are only a complement. The cost of these cables is generally higher than the one of the aerial power lines, thus its use is restricted only to those areas where the construction of the aerial power lines is not feasible. It is estimated that for voltages lower than 110 kV this cost is up to seven times greater than the one of an aerial power line and for voltages higher than 380 kV it can be up to twenty times greater. Nevertheless, important reasons exist to construct a subterranean cable system such as: a) the fast growth of the urban centers and the industrial zones, which brings about restrictions of the rights of way for the construction of aerial power lines, b) the crossing of large water bodies, c) the congestion of aerial power lines near the generating substations or power plants, d) the crossing of air lines and e) the laws and the regulations, to mention some of them. The importance of the underground transmission systems of high and extra high voltage will be increased in the medium and the long term, therefore, it is considered that the effects of the external phenomena in these systems, like the inductions produced by the electromagnetic transient sources, will be more severe. In this research work the atmospheric discharges are defined as the external electromagnetic transient sources. The large dimension cables such as the power cables, behave as large collectors of the interferences produced by the atmospheric discharges, which can bring about damages in the components of a system. In order to avoid the damages and to increase the reliability of the subterranean cable systems it is necessary to use protective devices and appropriate insulation levels, mainly. If the phenomenon and the behavior of the system are properly represented, it is possible to more accurately determine the characteristics that the equipment must have to resist the over voltages and the

  12. Experimental investigation on wake galloping appeared in tandem cables of cable-stayed bridges subjected to wind in skewed direction; Normal narabini dimple tsuki heiretsu cable ni senpu ga sayoshita baai no wake galloping tokusei ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M.; Miyachi, S.; Edamoto, K.; Mochizuki, H.; Setouchi, H. [Kawada Industries Inc., Tokyo (Japan)

    1996-03-20

    Concerning the smooth surface and dimpled surface cables, experiments were conducted to investigate relationship between their wake galloping characteristics and aerostatic force characteristics they demonstrate when exposed to wind blowing in a skewed direction. The wind tunnel used for the experiment was a closed type measuring wind tunnel, 2.0m wide, 2.5m high, and 15.0m long. In the wind tunnel, two cables were arranged with the distance between the cable centers three times as large as the cable diameter D, and with relative vertical difference of 0.25-0.50D, and spring-supported experiments for evaluating wake galloping characteristics and aerostatic force coefficient determining experiments were carried out. It was deemed as the result that turbulence exerts influence on the wake galloping characteristics of the dimpled surface cable more than on those of the smooth surface cable, that on a real bridge the effect of turbulence may be expected in case of exposure to natural wind of turbulence with intensity higher than 5-7%, and that therefore application of some damping by dampers will adequately damp wake galloping even in case of the 0.37D vertical difference. 12 refs., 23 figs.

  13. Compilation of radiation damage test data cable insulating materials

    CERN Document Server

    Schönbacher, H; CERN. Geneva

    1979-01-01

    This report summarizes radiation damage test data on commercially available organic cable insulation and jacket materials: ethylene- propylene rubber, Hypalon, neoprene rubber, polyethylene, polyurethane, polyvinylchloride, silicone rubber, etc. The materials have been irradiated in a nuclear reactor to integrated absorbed doses from 5*10/sup 5/ to 5*10/sup 6/ Gy. Mechanical properties, e.g. tensile strength, elongation at break, and hardness, have been tested on irradiated and non-irradiated samples. The results are presented in the form of tables and graphs, to show the effect of the absorbed dose on the measured properties. (13 refs).

  14. Production process for advanced space satellite system cables/interconnects.

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, Luis A.

    2007-12-01

    This production process was generated for the satellite system program cables/interconnects group, which in essences had no well defined production process. The driver for the development of a formalized process was based on the set backs, problem areas, challenges, and need improvements faced from within the program at Sandia National Laboratories. In addition, the formal production process was developed from the Master's program of Engineering Management for New Mexico Institute of Mining and Technology in Socorro New Mexico and submitted as a thesis to meet the institute's graduating requirements.

  15. Insulation coordination for HV AC underground cable systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Increasing environmental and aesthetic concerns regarding the utilisation of overhead electrical power transmission lines are resulting in a growing need to progress the use of underground alternatives. This increases the importance of looking for opportunities to further reduce the cost ratio between overhead and underground distribution and transmission. One approach is to address the inherent costs associated with the cable system by reducing the required withstand capability in line with the actual service requirements rather than traditional levels in particular the transient overvoltage performance. (author)

  16. Analytical Solution of Generalized Space-Time Fractional Cable Equation

    Directory of Open Access Journals (Sweden)

    Ram K. Saxena

    2015-04-01

    Full Text Available In this paper, we consider generalized space-time fractional cable equation in presence of external source. By using the Fourier-Laplace transform we obtain the Green function in terms of infinite series in H-functions. The fractional moments of the fundamental solution are derived and their asymptotic behavior in the short and long time limit is analyzed. Some previously obtained results are compared with those presented in this paper. By using the Bernstein characterization theorem we find the conditions under which the even moments are non-negative.

  17. Numerical simulation of fractional Cable equation of spiny neuronal dendrites.

    Science.gov (United States)

    Sweilam, N H; Khader, M M; Adel, M

    2014-03-01

    In this article, numerical study for the fractional Cable equation which is fundamental equations for modeling neuronal dynamics is introduced by using weighted average of finite difference methods. The stability analysis of the proposed methods is given by a recently proposed procedure similar to the standard John von Neumann stability analysis. A simple and an accurate stability criterion valid for different discretization schemes of the fractional derivative and arbitrary weight factor is introduced and checked numerically. Numerical results, figures, and comparisons have been presented to confirm the theoretical results and efficiency of the proposed method.

  18. Numerical simulation of fractional Cable equation of spiny neuronal dendrites

    Directory of Open Access Journals (Sweden)

    N.H. Sweilam

    2014-03-01

    Full Text Available In this article, numerical study for the fractional Cable equation which is fundamental equations for modeling neuronal dynamics is introduced by using weighted average of finite difference methods. The stability analysis of the proposed methods is given by a recently proposed procedure similar to the standard John von Neumann stability analysis. A simple and an accurate stability criterion valid for different discretization schemes of the fractional derivative and arbitrary weight factor is introduced and checked numerically. Numerical results, figures, and comparisons have been presented to confirm the theoretical results and efficiency of the proposed method.

  19. Micro-tunneling as an alternative to submarine cable

    Energy Technology Data Exchange (ETDEWEB)

    Russo, D.A. [Seattle City Light, WA (United States); Hansen, D. [CH2M Hill, Bellevue, WA (United States)

    1994-12-31

    The geography that gives Seattle its beauty can pose unique challenges for the engineers attempting to provide service to the customers who live near or upon these features. Steep, wooded hills and greenbelts create familiar problems of construction and right-of-way maintenance. The waterways and adjoining shoreline zones present a more difficult set of requirements. When Seattle City Light determined it was necessary to install 2-26 KV feeders across the Salmon Bay waterway, they discovered that submarine cables could not be used. Shallow angle directional drilling and micro-tunneling were examined and it was fond that a microtunneled duct bank was the best method to use.

  20. Succession of cable bacteria and electric currents in marine sediment

    DEFF Research Database (Denmark)

    Schauer, Regina; Risgaard-Petersen, Nils; Kjeldsen, Kasper Urup

    2014-01-01

    ][mu]m, with a general increase over time and depth, and yet they shared 16S rRNA sequence identity of >98%. Comparison of the increase in biovolume and electric current density suggested high cellular growth efficiency. While the vertical expansion of filaments continued over time and reached 30[thinsp]mm, the electric...... current density and biomass declined after 13 and 21 days, respectively. This might reflect a breakdown of short filaments as their solid sulphide sources became depleted in the top layers of the anoxic zone. In conclusion, cable bacteria combine rapid and efficient growth with oriented movement...

  1. Field Test of 3 phase, 22.9kV, 100m HTS Cable System in KEPCO

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, S H [Superconductivity and Application Group, Korea Electric Power Research Institute (Korea, Republic of); Choi, H S [Superconductivity and Application Group, Korea Electric Power Research Institute (Korea, Republic of); Kim, H R [Superconductivity and Application Group, Korea Electric Power Research Institute (Korea, Republic of); Hyun, O B [Superconductivity and Application Group, Korea Electric Power Research Institute (Korea, Republic of); Yim, S W [Department of superconductivity, University of Tokyo (Japan); Masuda, T [HTS R and D Department, Sumitomo Electric Industries Ltd (Japan); Yatsuka, K [HTS R and D Department, Sumitomo Electric Industries Ltd (Japan); Watanabe, M [HTS R and D Department, Sumitomo Electric Industries Ltd (Japan); Ryoo, H S [Underground System Group, Korea Electrotechnology Research Institute (Korea, Republic of); Yang, H S [High Magnetic Field R and D Team, Korea Basic Science Institute (Korea, Republic of); Kim, D L [High Magnetic Field R and D Team, Korea Basic Science Institute (Korea, Republic of); Hwang, S D [Superconductivity and Application Group, Korea Electric Power Research Institute (Korea, Republic of)

    2006-06-01

    Starting from investigation of feasibility and basic studies, KEPCO/KEPRI has carried an enterprising project for HTS cable system since 2002. The objectives of this project are to demonstrate HTS cable system and evaluate the feasibility in electricity utility's view. The installation of 100m/3phase/22.9kV/50MVA HTS cable system is undergoing in KEPCO's test yard, located in Gochang, Korea. The HTS cable system consists of 100m long cable, two terminations and a cooling system. To simulate the actual cable installation, the 55m section of the 100m long cable was installed into an underground tunnel. Commissioning test is scheduled at the end of September, 2005 and followed by long term operation test. In this paper, the installation of HTS cable system and initial results of system operation will be summarized.

  2. 75 FR 79025 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-Cable Television...

    Science.gov (United States)

    2010-12-17

    ... Television Laboratories, Inc. Notice is hereby given that, on November 4, 2010, pursuant to Section 6(a) of...''), Cable Television Laboratories, Inc. (``CableLabs'') has filed written notifications simultaneously with...

  3. 78 FR 58559 - Notice Pursuant to the National Cooperative Research and Production Act of 1993-Cable Television...

    Science.gov (United States)

    2013-09-24

    ... Television Laboratories, Inc. Notice is hereby given that, on August 26, 2013, pursuant to Section 6(a) of...''), Cable Television Laboratories, Inc. (``CableLabs'') has filed written notifications simultaneously with...

  4. 77 FR 74877 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; Cable Television...

    Science.gov (United States)

    2012-12-18

    ... Television Laboratories, Inc. Notice is hereby given that, on November 13, 2012, pursuant to Section 6(a) of...''), Cable Television Laboratories, Inc. (``CableLabs'') has filed written notifications simultaneously with...

  5. 37 CFR 201.17 - Statements of Account covering compulsory licenses for secondary transmissions by cable systems.

    Science.gov (United States)

    2010-07-01

    ... charges for security, alarm or facsimile services, charges for late payments, or charges for pay cable or... apartment house) which is charged by the cable system for the basic service of providing secondary...

  6. submitter Performance Test of an 8 kA @ 10-T 4.2-K ReBCO-CORC Cable

    CERN Document Server

    Mulder, Tim; Mentink, Matthias; van der Laan, Danko; Dhalle, Marc; ten Kate, Herman

    2016-01-01

    CERN is developing high-current ReBCO conductor on round core (CORC) cables for application in future detector and accelerator magnets. A characterization test on a ReBCO-CORC cable sample and its joints is performed in the 10-T FRESCA cable test facility at CERN. The sample is taken from the first 12-m-long CORC production. Key is the characterization of the field- and temperature-dependent critical currents of the CORC cable at 1.9 K and 4.2 K. Secondary objectives include evaluating the response of the CORC cable to quenches and the performance of cylindrical low resistive cable terminals especially designed and manufactured for use on CORC cables. The 7.6-mm CORC cable features 8 kA at 4.2 K and 10 T, and the joint terminals show a 25 ± 5 - nΩ resistance for 20-cm length.

  7. From Cabling the Atlantic to Wiring the World: A Review Essay on the 150th Anniversary of the Atlantic Telegraph Cable of 1866.

    Science.gov (United States)

    Müller, Simone M

    The year 2016 witnesses the 150th anniversary of laying the first successful transatlantic telegraph cables. This review essay offers a critical rereading of existing scholarship while simultaneously suggesting new perspectives for research. Telegraphy = globalization, the history of wiring the world commencing with the Atlantic cable of 1866 seems to suggest. At the same time, this essay argues, this equation should make scholars uneasy and cautious of a possible technological determinism retracing its steps back into the middle of scholarly debates on globalization. More attention needs to be paid to whose globalization we are talking about, what the globalization of politics, markets, and media means in connection to communication, and whether the cables really started something radically new. 150 years after laying the "first" Atlantic cable, there is still room for research. New spaces, theories, and methodologies, as well as alternate user groups including women and subalterns, offer avenues to test established scholarship on global communications.

  8. Thermoelectric Outer Planets Spacecraft (TOPS) electronic packaging and cabling development summary report

    Science.gov (United States)

    Dawe, R. H.; Arnett, J. C.

    1974-01-01

    Electronic packaging and cabling activities performed in support of the Thermoelectric Outer Planets Spacecraft (TOPS) Advanced Systems Technology (AST) project are detailed. It describes new electronic compartment, electronic assembly, and module concepts, and a new high-density, planar interconnection technique called discrete multilayer (DML). Development and qualification of high density cabling techniques, using small gage wire and microminiature connectors, are also reported.

  9. Dynamics of actin cables in polarized growth of the filamentous fungus Aspergillus nidulans

    Directory of Open Access Journals (Sweden)

    Anna eBergs

    2016-05-01

    Full Text Available Highly polarized growth of filamentous fungi requires a continuous supply of proteins and lipids to the hyphal tip. This transport is managed by vesicle trafficking via the actin and microtubule cytoskeletons and their associated motor proteins. Particularly, actin cables originating from the hyphal tip are essential for hyphal growth. Although specific marker proteins to visualize actin cables have been developed in filamentous fungi, the exact organization and dynamics of actin cables has remained elusive. Here we visualized actin cables using tropomyosin (TpmA and Lifeact fused to fluorescent proteins in Aspergillus nidulans and studied the dynamics and regulation. GFP tagged TpmA visualized dynamic actin cables formed from the hyphal tip with cycles of elongation and shrinkage. The elongation and shrinkage rates of actin cables were similar and approximately 0.6 μm/s. Comparison of actin markers revealed that high concentrations of Lifeact reduced actin dynamics. Simultaneous visualization of actin cables and microtubules suggests temporally and spatially coordinated polymerization and depolymerization between the two cytoskeletons. Our results provide new insights into the molecular mechanism of ordered polarized growth regulated by actin cables and microtubules.

  10. Comparison of the cable coupling effects under two kinds of HEMP environment

    CERN Document Server

    Sun Bei Yun; Xie Yan Zhao

    2002-01-01

    There are various kinds of HEMP environment definitions. The coupling effects of electronic system are more different under different HEMP environment. The responds of cable of different length are investigated under 1976 HEMP and 1996 HEMP environment. The results indicate that the cable coupling effects under 1976 HEMP environment are more serious than those under 1996 HEMP environment

  11. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false TV interface devices, including cable system... FREQUENCY DEVICES Unintentional Radiators § 15.115 TV interface devices, including cable system terminal devices. (a) Measurements of the radiated emissions of a TV interface device shall be conducted with the...

  12. ESTIMATION CRITERIA FOR DEGREE OF PAPER-IMPREGNATED INSULATED POWER CABLE AGEING

    Directory of Open Access Journals (Sweden)

    G.V. Bezprozvannych

    2013-09-01

    Full Text Available Correlation between parameters characterizing mechanical and thermal ageing of paper-impregnated insulation of medium voltage power cables is revealed. On the basis of linear and exponential regression analysis at confidence coefficient of 0.95, critical values of dielectric loss tangent of wrapping and phase insulation corresponding to the cable life termination are found.

  13. Compressive sampling based approach for identification of moving loads distribution on cable-stayed bridges

    Science.gov (United States)

    Bao, Yuequan; Li, Hui; Zhang, Fujian; Ou, Jinping

    2013-04-01

    A moving loads distribution identification method for cable-stayed bridges based on compressive sampling (CS) technique is proposed. CS is a technique for obtaining sparse signal representations to underdetermined linear measurement equations. In this paper, CS is employed to localize moving loads of cable-stayed bridges by limit cable force measurements. First, a vehicle-bridge model for cable-stayed bridges is presented. Then the relationship between the cable force and moving loads is constructed based on the influence lines. With the hypothesis of sparsity distribution of vehicles on bridge deck (which is practical for long-span bridges), the moving loads are identified by minimizing the `l2-norm of the difference between the observed and simulated cable forces caused by moving vehicles penalized by the `l1-norm' of the moving load vector. The resultant minimization problem is convex and can be solved efficiently. A numerical example of a real cable-stayed bridge is carried out to verify the proposed method. The robustness and accuracy of the identification approach with limit cable force measurement for multi-vehicle spatial localization are validated.

  14. Study of special spacer with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges and its application to full scale bridge; Nendanseitai wo riyoshita heiretsu cable yo gensui kinotsuki spacer to sono jikkyo cable eno tekiyo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M.; Setouchi, H.; Yoshioka, A. [Kawada Industries Inc., Tokyo (Japan); Shimoda, I.; Kawahara, S. [Oiles Corp., Tokyo (Japan)

    1996-12-20

    Cable vibration called wake galloping occurs in a cable-stayed bridge, in which cables are arranged tandem, and suppression of the vibration is an extremely important discussion item. This paper describes a complex eigen value analysis performed on tandem cables having lengths of 200 m and 100 m. The analysis revealed that damping characteristics added by a spacer system with a damping device (a type to install a visco-elastic body at about middle of the tandem cables via a jig) depend largely on torsional rigidity of the cables; and the characteristics may vary with difference in intervals between cable centers and that in cable diameters. A visco-elastic damping material of an asphalt system and a spacer with a damping device used as a spring material were fabricated and applied to a full scale bridge to identify quantitatively the damping addition characteristics of this system. Furthermore, the results of tests on the full scale bridge were compared with the result of the complex eigen value analysis, from which findings useful for actual works were obtained. 18 refs., 17 figs., 6 tabs.

  15. 47 CFR 76.1507 - Competitive access to satellite cable programming.

    Science.gov (United States)

    2010-10-01

    ... programming. 76.1507 Section 76.1507 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST... access to satellite cable programming. (a) Any provision that applies to a cable operator under §§ 76... provides video programming on its open video system, except as limited by paragraph (a) (1)-(3) of this...

  16. Thermal Behaviour of Low Voltage Cables in Smart Grid - Related Environments

    NARCIS (Netherlands)

    N.F. Höning (Nicolas); E. de Jong (Erik); G. Bloemhof; J.A. La Poutré (Han); Ö. Usta

    2014-01-01

    htmlabstractLow voltage cables in distribution grids will operate under harmful conditions more often in the near future, due to the integration of renewable energy sources and the addition of powerful consumption appliances. It is crucial to evaluate smart solutions that can prolong cable

  17. INVESTIGATION OF LOSSES IN INSULATION OF HIGH-VOLTAGE CABLES WITH XLPE INSULATION

    Directory of Open Access Journals (Sweden)

    L.A. Shchebeniuk

    2016-09-01

    Full Text Available In this paper the authors calculate the losses in insulation system cable with XLPE-polyethylene as a solid dielectric insulation and with semiconductor polyethylene used as a conductor screen and a insulation screen. The paper is devoted to the investigation of losses in the insulation system of high- voltage XLPE-cables. The line of XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. The dielectric losses are voltage depended and related to the insulation system materials being used. All current in this insulation system are complex quantities containing both real (Re(I and imaginary (Im(I parts. Values of the loss factor of the insulation system at power frequency tgd are given astgd = Re(I/Im(I. It was proposed the quantities criterion of the loss factor of the insulation system to high voltage XLPE-cables. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

  18. 75 FR 59645 - Radio Broadcast Services and Multichannel Video and Cable Television Service; Clarification...

    Science.gov (United States)

    2010-09-28

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Parts 73 and 76 Radio Broadcast Services and Multichannel Video and Cable Television... number of requirements related to Radio Broadcast Services and Multichannel Video and Cable Television...

  19. Interference to cable television due to mobile usage in the Digital Dividend - Analysis

    NARCIS (Netherlands)

    Robijns, Jan; Schiphorst, Roelof

    2011-01-01

    The use of mobile applications in the 800 MHz band, which forms part of the ‘Digital Dividend’, may cause interference to cable TV signals under certain conditions. The new mobile applications (called LTE, Long Term Evolution) use frequency bands also used in cable TV networks. This paper discusses

  20. 77 FR 60333 - Verification of Statements of Account Submitted by Cable Operators and Satellite Carriers

    Science.gov (United States)

    2012-10-03

    ... Copyright Office 37 CFR Part 201 Verification of Statements of Account Submitted by Cable Operators and... Statements of Account and royalty payments that are deposited with the Office by cable operators and... request for comments concerning a new regulation that will allow copyright owners to audit the Statements...

  1. A cable-driven parallel mechanism for the interaction with hemispherical surfaces

    NARCIS (Netherlands)

    Voss, K.H.J.; van der Wijk, V.; Herder, Justus Laurens; Viadero, Fernando; Ceccarelli, Marco

    2012-01-01

    In this paper, a device based upon a specific cable-driven parallel mechanism to interact with hemispherical surfaces is proposed and investigated. This device could be of use in, for example, the automated cleaning of glass domes. Because the cables move on the hemispherical surface, they are

  2. Laboratory Results from Dielectric Spectroscopy of Field Aged XLPE Cables with Respect to Water Trees

    DEFF Research Database (Denmark)

    Pedersen, Kenneth; Sedding, Howard; Fenger, Mark

    2006-01-01

    This paper deals with the application of frequency domain dielectric spectroscopy for the detection of water trees in XLPE cables. During the research, dielectric spectroscopy measurements have been carried out on cable samples with and without water trees while it was attempted to preserve many ...

  3. High temperature superconductors as a technological discontinuity in the power cable industry

    Energy Technology Data Exchange (ETDEWEB)

    Beales, T.P.; McCormack, J.S. [BICC Cables Ltd., Hebburn (United Kingdom)

    1994-12-31

    The advent of superconductivity above 77 K represents to the power cable industry a technological discontinuity analogous to that seen in the copper telecommunications industry by the arrival of optical fibres. This phenomenon is discussed along with technical criteria and performance targets needed for high temperature superconducting wire to have an economic impact in transmission cables.

  4. Harmonic modelling, propagation and mitigation for large wind power plants connected via long HVAC cables

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Hjerrild, Jesper; Kocewiak, Łukasz

    2016-01-01

    be reduced and operational availability and the reliability can be improved. Challenges hereto include lower resonance frequencies due to the long cables, frequency dependent modelling of long submarine cables, passive filtering, and PLL dynamics in the control loops (from a harmonic stability point of view)....

  5. 7 CFR 1755.902 - Minimum performance Specification for fiber optic cables.

    Science.gov (United States)

    2010-01-01

    ...) Environmental stress crack resistance test. For large cables (outside diameter ≥ 30 mm (1.2 inch)), test per... Bonding-to-Metal, Heat Sealability, Lap-Shear and Moisture Resistance requirements of Type I, Class 2... exceed 0.05 dB which allows for measurement noise that may be encountered during the test. The cable must...

  6. Assessing the feasibility and profitability of cable logging in southern upland hardwood forests

    Science.gov (United States)

    Chris B. LeDoux; Dennis M. May; Tony Johnson; Richard H. Widmann

    1995-01-01

    Procedures developed to assess available timber supplies from upland hardwood forest statistics reported by the USDA Forest Services' Forest Inventory and Analysis unit were modified to assess the feasibility and profitability of cable logging in southern upland hardwood forests. Depending on the harvest system and yarding distance used, cable logging can be...

  7. Fatigue of threaded rods in cable anchorages due to Vortex shedding

    NARCIS (Netherlands)

    Maljaars, J.; Snijder, H.H.

    2013-01-01

    The 'Hovenring' is a bicycle roundabout flyover built as a signature bridge with a central steel pylon carrying a circular bridge deck suspended through stay-cables. Shortly after installation of the bridge, the stay-cables turned out to vibrate in the wind due to vortex shedding. These vibrations

  8. Fatigue failure analysis of stay cables with initial defects: Ewijk bridge case study

    NARCIS (Netherlands)

    Maljaars, J.; Vrouwenvelder, A.C.W.M.

    2014-01-01

    A failure assessment method of stay cables containing fractured wires is presented through an example of an existing bridge. The wires constituting the stay cables of the bridge contained many initial defects that were formed during the rolling process of these wires. Despite moderate loading,

  9. 49 CFR 234.219 - Gate arm lights and light cable.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Gate arm lights and light cable. 234.219 Section... Maintenance, Inspection, and Testing Maintenance Standards § 234.219 Gate arm lights and light cable. Each gate arm light shall be maintained in such condition to be properly visible to approaching highway...

  10. The insulation coordination and surge arrester design for HTS cable system in Icheon substation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hansang, E-mail: Hansang80@korea.ac.kr [School of Railway and Electrical Engineering, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Yoon, Dong-Hee [Department of New and Renewable Energy, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Lee, Seung-Ryul [Korea Electrotechnology Research Institute, Naeson-dong, Uiwang-si, Gyeonggi-do 437-080 (Korea, Republic of); Yang, Byeong-Mo [Korea Electric Power Research Institute, Munji-dong, Yuseong-gu, Daejeon 305-760 (Korea, Republic of); Jang, Gilsoo, E-mail: gjang@korea.ac.kr [School of Electrical Engineering, Korea University, Anam-dong 5-ga, Seongbuk-gu, Seoul 136-713 (Korea, Republic of)

    2013-01-15

    Highlights: ► It is necessary to study lightning response of the HTS cable. ► The analytic model has been developed for the HTS cable in the Icheon substation. ► Well-designed surge arrester has been verified through PSCAD/EMTDC simulations. -- Abstract: This paper proposes an insulation coordination and surge arrester design for HTS (High-Temperature Superconducting) cable system in Icheon substation in Korea. In the aspect of the economic analysis, since the HTS cable is very expensive, the insulation coordination to prevent the dielectric breakdown caused by the lightning surge should be considered carefully. Also, in the aspect of the power system reliability, since the HTS cable has much more capacity compared than conventional power cables and the ripple effect from the HTS cable failure may lead to the wide area blackout, an intensive study for insulation coordination from lightning surge is one of the most important considerations. In this paper, the insulation coordination for lightning surge is verified using HTS cable and power equipment models and the design of the proper surge arrester is proposed.

  11. Instrument comprising a cable or tube provided provided with a propulsion device

    NARCIS (Netherlands)

    Breedveld, P.

    2006-01-01

    The invention relates to an instrument (1) comprising a cable or tube (3), at a distal end of which a propulsion device (4) is provided for moving the cable or tube in a hollow space, the propulsion device being shaped like a donut lying in a plane at right angles to the longitudinal direction of

  12. submitter Geometrical Behavior of $Nb_{3}Sn$ Rutherford Cables During Heat Treatment

    CERN Document Server

    Durante, Maria; Ferracin, Paolo; Manil, Pierre; Perez, Juan Carlos; Rifflet, Jean-Michel; Rondeaux, Francoise

    2016-01-01

    In $Nb_{3}Sn$ accelerator magnets, non-superconducting precursor cables are wound into their final coil shape and then heat treated at a high temperature to form the A15 superconducting phase. The growth of cable strands during reaction and the differential thermal dilatation in the coil components lead to both stress in the cable and geometrical deformations of the winding, with possible consequences on magnet performances. An experimental campaign on different types of Rutherford cables has been carried out at CEA Saclay, in collaboration with CERN, in order to measure cable dimension changes in all directions, with respect to cable configuration and winding geometry. A 700-mm-long versatile test bench has been designed for several cable topologies up to 22 mm in width. This paper describes the tooling and presents the results of the experimental campaign led on the cables, made of powder-in-tube and restacked-rod-process strands, of FRESCA2, a 13-T dipole magnet

  13. Measuring ac-loss in high temperature superconducting cable-conductors using four probe methods

    DEFF Research Database (Denmark)

    Kühle (fratrådt), Anders Van Der Aa; Træholt, Chresten; Olsen, Søren Krüger

    1999-01-01

    Measuring the ac-loss of superconducting cable conductors have many aspects in common with measuring the ac-loss of single superconducting tapes. In a cable conductor all tapes are connected to each other and to the test circuit through normal metal joints in each end. This makes such measurements...

  14. Influence of Frequency Converters on Insulation of Power Supply Cables at Oil-Producing Stations

    Directory of Open Access Journals (Sweden)

    D. I. Zalizny

    2011-01-01

    Full Text Available The paper considers consequences of negative frequency converter influence on insulation of  power supply cables used for submersible installations of electric-centrifugal pumps at oil-producing stations. The possible approaches to the solution of the problem are proposed on the basis of a harmonic analysis of actually measured voltages and currents in a cable.  

  15. 49 CFR 236.108 - Insulation resistance tests, wires in trunking and cables.

    Science.gov (United States)

    2010-10-01

    ... dry. Insulation resistance tests shall be made between all conductors and ground, and between conductors in each multiple conductor cable, and between conductors in trunking, when wires or cables are... annually. (c) In no case shall a circuit be permitted to function on a conductor having an insulation...

  16. 49 CFR 234.267 - Insulation resistance tests, wires in trunking and cables.

    Science.gov (United States)

    2010-10-01

    ... be made between all conductors and ground, between conductors in each multiple conductor cable, and between conductors in trunking. Insulation resistance tests shall be performed when wires, cables, and... be made annually. (d) A circuit with a conductor having an insulation resistance of less than 200,000...

  17. First superconductor cables manufactured at CERN. Gianfalco Pozzo briefs visitors from industry.

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    At the MSC Workshop in Bld 108: on the table some samples of cable of different diameter. A cable of this type was used for the construction of a very light solenoid needed for the experiment R108 at the ISR. M.Morpurgo and G. Pozzo, Fabrication of an aluminium stabilized superconductor (see Cryogenics, February 1977, p.87).

  18. Method and system for controlling chemical reactions between superconductors and metals in superconducting cables

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Tengming

    2018-01-02

    A method, system, and apparatus for fabricating a high-strength Superconducting cable comprises pre-oxidizing at least one high-strength alloy wire, coating at least one Superconducting wire with a protective layer, and winding the high-strength alloy wire and the Superconducting wire to form a high-strength Superconducting cable.

  19. Static Dissipative Cable Ties, Such as for Radiation Belt Storm Probes

    Science.gov (United States)

    Langley, Patrick T. (Inventor); Siddique, Fazle E. (Inventor)

    2015-01-01

    An article, such as, but not limited to, a cable strap to wrap, support, or secure one or more wires or cables, is formed by cyclically heating and cooling and/or irradiating an article formed of a static dissipative ethylene tetrafluoroethylen (ETFE) resin, to reduce an electrical resistivity and/or to increase a tensile strength of the article.

  20. Difference in Stability Between Edge and Center in a Rutherford Cable

    NARCIS (Netherlands)

    Willering, G.P.; Verweij, A.P.; Scheuerlein, C.; den Ouden, A.; ten Kate, Herman H.J.

    Keystoned superconducting Rutherford cables are widely used in accelerator magnets like in the LHC at CERN. An essential requirement in the cable design is its stability against local heat releases in the magnet windings originating from for example, strand movement or beam loss. Beam loss is the