  1. State of the art analysis of online fault location on AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Gudmundsdottir, Unnur Stella; Bak, Claus Leth

    2011-01-01

    In this article the state of the art research for online fault location on cross-bonded transmission level cables is presented. The article is focused on the difficulties in using the algorithms developed for OHL-systems and distribution cables directly on cross-bonded transmission cables. Impeda...

  2. Online Fault Location on AC Cables in Underground Transmission Systems using Sheath Currents

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Nanayakkarab, Kasun; Rajapakse, Athula

    2014-01-01

    This paper studies online travelling wave methods for fault location on a crossbonded cable system using sheath currents. During the construction of the electrical connection to the 400 MW off shore wind farm Anholt, it was possible to perform measurements on a 38.4 km crossbonded cable system. A...

  3. Online fault location on AC cables in underground transmission systems using screen currents

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Nanayakkara, O.M.K.K; Rajapakse, Athula

    This paper studies online travelling wave methods for fault location on a crossbonded cable system using screen currents. During the construction of the electrical connection to the 400 MW off shore wind farm Anholt, it was possible to perform measurements on a 38.4 km crossbonded cable system. A...

  4. Online fault location on AC cables in underground transmission systems using screen currents

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Nanayakkara, O.M.K.K; Rajapakse, Athula

    This paper studies online travelling wave methods for fault location on a crossbonded cable system using screen currents. During the construction of the electrical connection to the 400 MW off shore wind farm Anholt, it was possible to perform measurements on a 38.4 km crossbonded cable system...... coils if the screen currents contain the necessary information for accurate fault location. In this paper, this is examined by analysis of field measurements and through a study of simulations. The wavelet transform and visual inspection methods are used and the accuracy is compared. Field measurements...... and simulations are compared for testing the reliability of using simulations for studying fault location methods....

  5. Online Location of Faults on AC Cables in Underground Transmission Systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær

    parts; The preliminaries, a part which deals with the use of impedance-based fault location methods on crossbonded cables, a part which deals with travelling wave-based fault location, a part listing the conclusions and contributions of the thesis and an appendix. A state-of-the-art analysis......A transmission grid is normally laid out as an almost pure overhead line (OHL) network. The introduction of transmission voltage level XLPE cables and the increasing interest in the environmental impact of OHL has resulted in an increasing interest in the use of underground cables on transmission...... level. In Denmark for instance, the entire 150 kV, 132 kV and 220 kV and parts of the 400 kV transmission network will be placed underground before 2030. To reduce the operating losses of a cable-based transmission system, crossbonding schemes are normally used. The use of crossbonding introduces new...

  6. First Field Experience of On-line Partial Discharge Monitoring of MV Cable Systems with location

    Energy Technology Data Exchange (ETDEWEB)

    Van der Wielen, P.; Steennis, F.

    2009-06-15

    A new measuring system is presented for the on-line monitoring and location of partial discharges (PDs) in medium-voltage power cables. The system uses two inductive sensors, each at one cable end. The measuring system is called PD-OL, which stands for PD detection Online with Location. A pulse injection system is used for the time synchronization of the data intake at both cable ends and for the on-line calibration. PD data is send via internet to the KEMA Control Center for interpretation and final presentation, made visible on a secured website for the network owners. This paper discusses the basics of PD-OL and a number of measurement results.

  7. VT Cable Systems 2013

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable dataset (CABLE2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013 in addition to...

  8. Online fault location on crossbonded AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    F. Jensen, Christian; Bak, Claus Leth; Gudmundsdottir, Unnur Stella

    2014-01-01

    system are identified. The fault locator system uses the Wavelet Transform both to create reliable triggers in the units and to estimate the fault location based on time domain signals obtained in the substations by two fault locator units. Field measurements of faults artificially created on a section...

  9. Development of buried cable location survey system by underground rader for power distribution cables under pavements. Haiden chichuka no tame no chika radar ni yoru maisetsukan tansa system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K.; Kitano, K.

    1990-06-01

    To execute construction work for power distribution cables under pavements reasonably, it is important to develop a technology capable of non-destructive detection of the location of existing buried cables from the ground surface. This study is to clarify the principle, measurement method, effectiveness, and limitation of the underground radar system which is at present considered as the most effective survey method for buried cables. In this system, accuracy in measuring the depth of underground cable location by a separated type antenna has been improved, software to improve resolution by a migration process has been developed, and a compact survey system which can analyze the data on the site has been realized. As aresult of the survey at city areas, all pipes buried less than 1m in depth with the resistivity value of more than 100 {Omega} m were detected as well as those less than 2m in depth with more than some 100 {Omega} m. However, non-metal pipes buried deeper than 1m in the ground of less than 100 {Omega} m were not detected. Consequently, improvement of the system is necessary in future. 7 refs., 23 figs., 6 tabs.

  10. New Passive Methodology for Power Cable Monitoring and Fault Location

    Science.gov (United States)

    Kim, Youngdeug

    The utilization of power cables is increasing with the development of renewable energy and the maintenance replacement of old overhead power lines. Therefore, effective monitoring and accurate fault location for power cables are very important for the sake of a stable power supply. The recent technologies for power cable diagnosis and temperature monitoring system are described including their intrinsic limitations for cable health assessment. Power cable fault location methods are reviewed with two main categories: off-line and on-line data based methods. As a diagnostic and fault location approach, a new passive methodology is introduced. This methodology is based on analyzing the resonant frequencies of the transfer function between the input and output of the power cable system. The equivalent pi model is applied to the resonant frequency calculation for the selected underground power cable transmission system. The characteristics of the resonant frequencies are studied by analytical derivations and PSCAD simulations. It is found that the variation of load magnitudes and change of positive power factors (i.e., inductive loads) do not affect resonant frequencies significantly, but there is considerable movement of resonant frequencies under change of negative power factors (i.e., capacitive loads). Power cable fault conditions introduce new resonant frequencies in accordance with fault positions. Similar behaviors of the resonant frequencies are shown in a transformer (TR) connected power cable system with frequency shifts caused by the TR impedance. The resonant frequencies can be extracted by frequency analysis of power signals and the inherent noise in these signals plays a key role to measure the resonant frequencies. Window functions provide an effective tool for improving resonant frequency discernment. The frequency analysis is implemented on noise laden PSCAD simulation signals and it reveals identical resonant frequency characteristics with theoretical

  11. VT Cable Modem Systems 2013

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013. This data...

  12. VT Cable Modem Systems 2005

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2005) includes lines depicting the extent of Vermont's cable modem broadband system as of 12/31/2005. This...

  13. 14 CFR 23.689 - Cable systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cable systems. 23.689 Section 23.689... Systems § 23.689 Cable systems. (a) Each cable, cable fitting, turnbuckle, splice, and pulley used must meet approved specifications. In addition— (1) No cable smaller than 1/8 inch diameter may be used...

  14. Buoyant Cable Antenna System

    Science.gov (United States)

    2008-07-02

    comprise a mechanical jacket surrounding a hollow core enclosing the seismic sensor and signal transfer means. Elongated axial stress elements for...to S. H. Bittleston, discloses a semi-dry marine seismic streamer cable that consists of a number of connected streamer cable sections which each...transmitting axial loads and a radial reinforcement member for relieving radial loads are provided in the jacket . The core is filled with a fluid or fluid

  15. 14 CFR 25.689 - Cable systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cable systems. 25.689 Section 25.689... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a) Each cable, cable fitting, turnbuckle, splice, and pulley must be approved. In addition— (1) No...

  16. Thermal analysis of underground power cable system

    Science.gov (United States)

    Rerak, Monika; Ocłoń, Paweł

    2017-10-01

    The paper presents the application of Finite Element Method in thermal analysis of underground power cable system. The computations were performed for power cables buried in-line in the ground at a depth of 2 meters. The developed mathematical model allows determining the two-dimensional temperature distribution in the soil, thermal backfill and power cables. The simulations studied the effect of soil and cable backfill thermal conductivity on the maximum temperature of the cable conductor. Also, the effect of cable diameter on the temperature of cable core was studied. Numerical analyses were performed based on a program written in MATLAB.

  17. Cable vibration control with both lateral and rotational dampers attached at an intermediate location

    Science.gov (United States)

    Chen, Lin; Sun, Limin; Nagarajaiah, Satish

    2016-09-01

    Lateral dampers have been extensively studied and implemented for supplementing modal damping in cable vibration mitigation. When considering the cable flexural stiffness that is actually present, albeit small, there is another degree of freedom of the cable at the lateral damper, namely the rotation, that can be constrained by a rotational damper to achieve larger additional damping. This is of particular significance for long cables where the near-anchorage lateral damper alone is usually insufficient. The problem of a cable with bending stiffness, attached with both lateral and rotational dampers at an intermediate point, is therefore considered in this study. The characteristic equation of the resulting system is formulated by assembling the dynamic stiffness from the two segments divided by the damper, which is subsequently solved using argument principle method. Dynamics of the controlled system is thus discussed in general through parametric analysis. For the case where the damper location is close to the anchorage, asymptotic solutions for complex frequency and damping ratio are provided; explicit formulas for determining the optimal damper coefficients are also derived. It is found that when the lateral and rotational damper coefficients are properly balanced, the proposed strategy can achieve up to 30 percent damping enhancement compared to the case with only the lateral damper, in practical cable bending stiffness range.

  18. temperature distribution in underground cable system

    Directory of Open Access Journals (Sweden)

    Rerak Monika

    2017-01-01

    Full Text Available The paper presents a mathematical model of heat transfer in the underground cable system. The computations were performed for flat formation of power cables buried in the ground at a depth of 2 meters. The model allows determining the two-dimensional temperature distribution in the soil, thermal backfill and power cables. The simulations studied the effect of soil thermal conductivity on the maximum temperature of the cable conductor. Furthermore, the effect of thermal backfill soil conductivity on the cable conductor temperature was studied. Numerical analyses were performed based on a program written in MATLAB.

  19. Fault location in underground cables using ANFIS nets and discrete wavelet transform

    Directory of Open Access Journals (Sweden)

    Shimaa Barakat

    2014-12-01

    Full Text Available This paper presents an accurate algorithm for locating faults in a medium voltage underground power cable using a combination of Adaptive Network-Based Fuzzy Inference System (ANFIS and discrete wavelet transform (DWT. The proposed method uses five ANFIS networks and consists of 2 stages, including fault type classification and exact fault location. In the first part, an ANFIS is used to determine the fault type, applying four inputs, i.e., the maximum detailed energy of three phase and zero sequence currents. Other four ANFIS networks are utilized to pinpoint the faults (one for each fault type. Four inputs, i.e., the maximum detailed energy of three phase and zero sequence currents, are used to train the neuro-fuzzy inference systems in order to accurately locate the faults on the cable. The proposed method is evaluated under different fault conditions such as different fault locations, different fault inception angles and different fault resistances.

  20. 47 CFR 76.640 - Support for unidirectional digital cable products on digital cable systems.

    Science.gov (United States)

    2010-10-01

    ... products on digital cable systems. 76.640 Section 76.640 Telecommunication FEDERAL COMMUNICATIONS... Standards § 76.640 Support for unidirectional digital cable products on digital cable systems. (a) The requirements of this section shall apply to digital cable systems. For purposes of this section, digital...

  1. Diagnostics and testing of high voltage cable systems

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, P.; Oyegoke, B.; Aro, M.

    2003-07-01

    Reliability demands on electricity generation and distribution are increasing. Power utilities have faced new challenges due to liberalisation of electricity markets, increasing authors regulation and new claims for compensation of unexpected power shut downs. As a result power utilities have to concentrate more on asset management to reduce costs, to postpone investments, to optimise technical management keeping at the same time reliability and power quality at high level. Nowadays it is important to do right things at right place at right time. Maintenance strategy is changing from predictive or repairing maintenance to the condition based maintenance (CBM). Success of CBM depends partly on how good and reliable tools are available to determine condition of electrical apparatus. Cables have been used in electricity distribution since beginning of 20th century. Oldest still in use cables in Finland has been installed late 1940's. Nowadays almost all new distribution systems in urban areas are done using cables. Wide variety of cables are in use. Knowledge of condition and history of cables is not so well documented. Professional skill to install cable systems is disappearing due to outsourcing of maintenance groups. There is a worry about increasing amount of after installation faults due to loosing of professional skills to install cable systems. Wide variety of cable insulation systems and large variety in ages of cables still in use will place hard challenges for cable condition assessment. Earlier studies showed that measurement of insulation resistance is almost only diagnostic measurement performed to cable systems. Knowledge and experience of new diagnostic method is not so widely distributed. Based on previous project, dielectric response (DR) measurement and partial discharge (PD) measurement seemed to be most promising tools for the condition assessment of cable systems. Increased moisture content in oil-paper insulated cable or water trees in

  2. An Online Monitoring and Fault Location Methodology for Underground Power Cables

    Science.gov (United States)

    Govindarajan, Sudarshan

    With the growing importance of underground power systems and the need for greater reliability of the power supply, cable monitoring and accurate fault location detection has become an increasingly important issue. The presence of inherent random fluctuations in power system signals can be used to extract valuable information about the condition of system equipment. One such component is the power cable, which is the primary focus of this research. This thesis investigates a unique methodology that allows online monitoring of an underground power cable. The methodology analyzes conventional power signals in the frequency domain to monitor the condition of a power cable. First, the proposed approach is analyzed theoretically with the help of mathematical computations. Frequency domain analysis techniques are then used to compute the power spectral density (PSD) of the system signals. The importance of inherent noise in the system, a key requirement of this methodology, is also explained. The behavior of resonant frequencies, which are unique to every system, are then analyzed under different system conditions with the help of mathematical expressions. Another important aspect of this methodology is its ability to accurately estimate cable fault location. The process is online and hence does not require the system to be disconnected from the grid. A single line to ground fault case is considered and the trend followed by the resonant frequencies for different fault positions is observed. The approach is initially explained using theoretical calculations followed by simulations in MATLAB/Simulink. The validity of this technique is proved by comparing the results obtained from theory and simulation to actual measurement data.

  3. Self-contained cable systems offer advantages

    Energy Technology Data Exchange (ETDEWEB)

    Morello, A.S.; Occhini, E.

    1977-05-01

    Low-pressure oil-filled (LPOF) cable systems, while seldom used in this country, have several advantages of interest to engineers. Less oil and insulating paper is required for low-pressure than for the more commonly used high-pressure systems because of the single core. The lower pessure offers safety features in the event of accidental oil loss. LPOF cables are used internationally because of their good thermal characteristics. Applications besides ac transmission lines include underground and submarine cables, such as those connecting islands with mainland facilities. Cooling can be accomplished either by circulating oil inside the central duct or circulating water through parallel nonmetallic pipes. Forced-cooling of the LPOF cables is less complicated, which allows them to have higher current ratings and makes them more adaptable to thermal transients. Conductor cooling, which increases capacity but prohibits overloads in LPOF cables, is the only system available to high voltage (HVDC) cables. Several experimental and demonstration cable systems are described. (DCK)

  4. Cable system transients theory, modeling and simulation

    CERN Document Server

    Ametani, Akihiro; Nagaoka, Naoto

    2015-01-01

    A systematic and comprehensive introduction to electromagnetic transient in cable systems, written by the internationally renowned pioneer in this field Presents a systematic and comprehensive introduction to electromagnetic transient in cable systems Written by the internationally renowned pioneer in the field Thorough coverage of the state of the art on the topic, presented in a well-organized, logical style, from fundamentals and practical applications A companion website is available

  5. Field application of a cable NDT system for cable-stayed bridge using MFL sensors integrated

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Choi, Jun Sung; Park, Seung Hee [Sungkyunkwan University, Seoul (Korea, Republic of); Lee, Eun Chan [Korea Maintance Co., Ltd., Seoul (Korea, Republic of)

    2014-02-15

    In this study, an automated cable non-destructive testing(NDT) system was developed to monitor the steel cables that are a core component of cable-stayed bridges. The magnetic flux leakage(MFL) method, which is suitable for ferromagnetic continuum structures and has been verified in previous studies, was applied to the cable inspection. A multi-channel MFL sensor head was fabricated using hall sensors and permanent magnets. A wheel-based cable climbing robot was fabricated to improve the accessibility to the cables, and operating software was developed to monitor the MFL-based NDT research and control the climbing robot. Remote data transmission and robot control were realized by applying wireless LAN communication. Finally, the developed element techniques were integrated into an MFL-based cable NDT system, and the field applicability of this system was verified through a field test at Seohae Bridge, which is a typical cable-stayed bridge currently in operation.

  6. Two-way cable television system characterization

    Science.gov (United States)

    Schauer, Paul T.

    1995-11-01

    This presentation is a report of the testing activities of the CableLabs Network Integrity Working Group. The working group consisted of several CableLabs member companies which conducted rf analog and digital bit-error testing at five CATV networks in the U.S. and Canada. The purpose of the working group was to measure the reliability and availability of the contemporary CATV network as specified by traditional switched access telephony performance parameters. Transmission data was collected for both forward and reverse (sub- split) paths of the rf broadband network, in both traditional and hybrid fiber/coax architectures, and for baseline and controlled variation events. The basic premise of this testing was to ascertain which cable television network elements adversely affected transmission of a 'generic' digital communications system and how they can be managed or controlled. The digital transmission utilized in the test was a QPSK modulated, T-1 rate (1.544 Mbit/second), modem without error correction. The intent was not to derive the necessary modulation technique and error correction scheme to properly operate in every cable television system, but rather to determine the principal sources of impairments existing in these networks and deduce corrective measures. The full report of the Network Integrity Working Group is published by CableLabs, Inc., and is titled, 'Two-Way Cable Television System Characterization -- Final Report', April 1995.

  7. 47 CFR 76.614 - Cable television system regular monitoring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system regular monitoring. 76.614 Section 76.614 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76.614 Cable television system regular monitoring. Cable television...

  8. 47 CFR 76.403 - Cable television system reports.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The operator of every operational cable...

  9. Sensitivity analyses of cables to suspen-dome structural system

    Institute of Scientific and Technical Information of China (English)

    高博青; 翁恩豪

    2004-01-01

    The construction of the cables is a key step for erecting suspen-dome structures. In practical engineering, it is difficult to ensure that the designed pre-stresses of cables have been exactly introduced into the structures in the site; so it is necessary to evaluate the influence of the variation of the pre-stresses on the structural behavior. In the present work, an orthogonal design method was employed to investigate the pre-stressed cables' sensitivity to the suspen-dome system. The investigation was concentrated on a Kiewitt suspen-dome. Parametric studies were carried out to study the sensitivity of the structure's static behavior, dynamic behavior, and buckling loads when the pre-stresses in the cables varied. The investigation indicated that suspen-dome structures are sensitive to the pre-stresses in all cables; and that the sensitivity depended on the location of the cables and the kind of structural behavior. Useful suggestions are given at the end of the paper.

  10. Sensitivity analyses of cables to suspen-dome structural system

    Institute of Scientific and Technical Information of China (English)

    高博青; 翁恩豪

    2004-01-01

    The construction of the cables is a key step for erecting suspen-dome structures. In practical engineering, it is difficult to ensure that the designed pre-stresses of cables have been exactly introduced into the structures in the site; so it is necessary to evaluate the influence of the variation of the pre-stresses on the structural behavior. In the present work, an orthogonal design method was employed to investigate the pre-stressed cables'sensitivity to the suspen-dome system. The investigation was concentrated on a Kiewitt suspen-dome. Parametric studies were carried out to study the sensitivity of the structure's static behavior, dynamic behavior, and buckling loads when the pre-stresses in the cables varied. The investigation indicated that suspen-dome structures are sensitive to the pre-stresses in all cables; and that the sensitivity depended on the location of the cables and the kind of structural behavior. Useful suggestions are given at the end of the paper.

  11. Single-end Partial Discharge Location in Power Cables Based on Phase Difference Method%Single-end Partial Discharge Location in Power Cables Based on Phase Difference Method

    Institute of Scientific and Technical Information of China (English)

    Redy Mardiana

    2011-01-01

    This paper describes the application of phase difference method for locating partial discharge (PD) in power cables from single-end measurement. The phase difference between the direct and reflected waves of a PD pulse at various frequencies can be obtained from the cross Fourier spectral density function. After implementing a phase unwrapping algorithm, the defect in the cable can be located. Unlike the time-domain reflectometry (TDR) methods, this technique does not need to estimate the arrival time of the PD signals. Laboratory experiments on a model of a 3.3 kV, 50 m underground cable have been carried out. The experimental results indicate that the proposed technique has better location accuracy compared to the commonly used time-domain methods.

  12. Parameters analysis for assistant cables of system for transient main cable and catwalk of long-span suspension bridges at construction stages

    Science.gov (United States)

    Li, Shengli; Ou, Jinping

    2009-03-01

    On the basis of static, dynamic and transient analysis for the prestressing cable structures, the parameters to control the vibration of the system for transient main cables and catwalk of some long-span suspension bridge at the construction stages with the assistant cables are investigated adopting the method of the finite element considering the geometry nonlinearity. The review and prospect to control vibration with assistant cables are summarized, the finite element modeling of the system for transient main cables and catwalk is established, and the influence of the position of the assistant cables, disposed fashion and the tensile forces upon the critical frequencies of the system for transient main cables and catwalk is researched. At the same time, the effect of the damp and the tensile forces of the assistant cables on the equivalent damping ratio of the system for transient main cables and catwalk inside and outside the plane is studied and the effect to control the vibration of the system is analysed. In the end, the influence of the transformation for the tensile forces about assistant cables upon those of the transient main cables and catwalk is also investigated. Results show that, to increase the critical frequencies of the system, the assistant cables should be laid vertically with the main cables and be located in interim span or between the tower and interim span, and to increase the amount of the assistant cables can increase the critical frequencies ,and to increase the rigidities of the assistant cables can improve the ones of the transient main cables but decrease the anti-torsion ability of the catwalks, and to increase the damp of the assistant cables can improve the vibration of the transient main cables inside and outside the plane but the result is little outside the plane, and in addition the effect of the rigidities of the assistant cables is larger outside the plane but is little inside the plane. The results also show that the

  13. Cryogenic cooling system for HTS cable

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeru [Taiyo Nippon Sanso, Tsukuba (Japan)

    2017-06-15

    Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

  14. Fast location of fiber cable troubles%快速光缆故障定位

    Institute of Scientific and Technical Information of China (English)

    董淑福; 倪延辉; 李维民; 魏会贤

    2001-01-01

    指出了光缆故障定位的措施,总结了各种光缆故障的原因及现象,分析了OTDR进行各种故障准确定位时所得后向散射信号曲线的特征。%In this paper the ways to locate fiber cable troubles fast are pointed out, the reasons and phenom-ena of various fiber cable troubles are also discussed. At last, the features of backscattering signal curveusing OTDR are analyzed when locating fiber cable trouble accurately.

  15. Distance and Cable Length Measurement System

    Directory of Open Access Journals (Sweden)

    Jonay Toledo

    2009-12-01

    Full Text Available A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement.

  16. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  17. 37 CFR 256.2 - Royalty fee for compulsory license for secondary transmission by cable systems.

    Science.gov (United States)

    2010-07-01

    ... section, 3.75 per centum of the gross receipts of the cable systems for each distant signal equivalent... market, (i) .599 per centum of such gross receipts for the first distant signal equivalent; (ii) .377 per... additional distant signal equivalent thereafter; (2) For cable systems located wholly or in part within...

  18. 30 CFR 75.817 - Cable handling and support systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Cable handling and support systems. 75.817... High-Voltage Longwalls § 75.817 Cable handling and support systems. Longwall mining equipment must be provided with cable-handling and support systems that are constructed, installed and maintained to...

  19. New Sensor Cable for the Detection and Location of Leaks in Pipelines for Transportation of Hydrocarbons

    Directory of Open Access Journals (Sweden)

    E.Orduña-Reyes

    2012-08-01

    Full Text Available At present, hydrocarbon leaks, generated mainly by corrosion of pipelines, cause large economic losses for Mexico.These leaks constitute a problem of serious consequences in Mexico and in other countries in the world. This workdescribes the results of the tests conducted on a new sensor cable for the detection and location of leaks in pipelinesfor transportation of hydrocarbons. When a liquid or gas enters in contact with the wall of the sensor cable, it causes ashort circuit in the wires; changing the measurement of the resistance may detect and locate the leak. The new sensorcable that is presented in this article has advantages over cables with similar characteristic made in other countries.The use of this sensor cable in pipelines of PEMEX will avoid economic losses, environmental damage and risks ofpossible explosions to the population. The experimental results demonstrate these advantages.

  20. OVERLOAD CAPABILITY OF POWER CABLES IN ACTUAL POWER CONSUMPTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    L.A. Szhebenyuk

    2013-09-01

    Full Text Available Results of overload capability calculations for 6-kV power cables are analyzed. The work is aimed at creating a computation system for the current rating of high-voltage cross-linked polyethylene power cables.

  1. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    Power transmission is facing its largest challenges ever with regards to handling a transition from today’s fossil‐based power production into renewable sources of generation. We can no longer place power plants close to centres of consumption; they must be located where the natural resources...... the role of interconnecting these generation/load centres, ensuring fair reliability and redundancy of supply. Nowadays, the power transmission system must be able to handle the various sources of renewable generation in a flexible electricity market. This has the consequence that the original layout...... cables is given, and secondly, the modelling approach and validation of this is discussed. Thirdly, making up the main core of the work presented, dynamics of underground cable systems are discussed and important cases to study are highlighted, and next, protection and fault location are discussed...

  2. Dynamic Analysis of Towed and Variable Length Cable Systems

    Institute of Scientific and Technical Information of China (English)

    WANG Shu-xin; WANG Yan-hui; LI Xiao-ping

    2007-01-01

    Towed cable systems are frequently used in marine measurements where the length of the towed cable varies during launch and recovery. In this paper a novel method for modeling variable length cable systems is introduced based on the finite segment formulation. The variable length of the towed cable is described by changing the length of the segment near the towing point and by increasing or decreasing the number of the discrete segments of the cable. In this way, the elastic effects of the cable can be easily handled since geometry and material properties of each segment are kept constant. Experimental results show that the dynamic behavior of the towed cable is consistent between the model and the physical cable. Results show that the model provides numerical efficiency and simulation accuracy for the variable length towed system.

  3. A Flexible Recommendation System for Cable TV

    OpenAIRE

    Goncalves, Diogo; Costa, Miguel; Couto, Francisco M.

    2016-01-01

    Recommendation systems are being explored by Cable TV operators to improve user satisfaction with services, such as Live TV and Video on Demand (VOD) services. More recently, Catch-up TV has been introduced, allowing users to watch recent broadcast content whenever they want to. These services give users a large set of options from which they can choose from, creating an information overflow problem. Thus, recommendation systems arise as essential tools to solve this problem by helping users ...

  4. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  5. Dynamic model and workspace analysis of novel incompletely restrained cable-suspension swing system driven by two cables

    Directory of Open Access Journals (Sweden)

    Naige Wang

    2017-03-01

    Full Text Available The incompletely restrained cable-suspension swing system driven by two cables is introduced in this article. Based on wrench of forces theory and Lagrange’s equation of first kind, the static and dynamics models of incompletely restrained cable-suspension swing system driven by two cables are established, respectively. In order to obtain an intuitive understanding of the trajectory analysis, a dynamics model consisting of governing equation and geometric constraint conditions which is a set of the mixed differential-algebraic equation in mathematics is established. A typical feedback controller and an inverse model were set up to estimate the driving function. The effective workspace, which is used to guarantee an efficient swing process, mostly depends on the geometrical shape rather than the volume itself which was calculated by trajectory analysis. In order to estimate system features and ensure a limited range of tension in underconstrained spatial cable system, the probable location of unbalanced loading was evaluated by pointwise evaluation techniques during normal work.

  6. Security television monitoring using a wideband radio-frequency cable system

    Energy Technology Data Exchange (ETDEWEB)

    Russell, J.A.; Case, A.L.; Crutcher, R.I.; Wetzell, F.E.

    1981-01-01

    The Oak Ridge National Laboratory (ORNL) was equipped with a multichannel, bidirectional rf cable television system for security assessment. The multichannel cable system was selected over a more conventional video cable system that has separate cables to each camera. Primary considerations for election of the rf cable system were initial cost and ease of midification or additions to the system. Two, 300-MHz cables, having a capacity of approx. 60 channels, and modulators and demodulators for 40 channels were installed. The modulators, located in buildings or building complexes, receive video signals from 40 TV cameras. These signals are transmitted as rf signals by the cable system to centralized emergency control center (ECC) where they are demodulated, processed, and displayed by the video equipment. TV monitors, digital video motion detectors, and recorders enable the dispatcher in the ECC to evaluate and document the video information. This paper covers the justification for a TV system and the reasons for selecting an rf cable system. It includes a discussion of the design criteria, installation, and expansion capabilities of the system.

  7. 47 CFR 1.1155 - Schedule of regulatory fees and filing locations for cable television services.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Schedule of regulatory fees and filing locations for cable television services. 1.1155 Section 1.1155 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND PROCEDURE Schedule of Statutory Charges and Procedures for Payment § 1.1155 Schedule of regulatory fees and filing...

  8. Study on the Fault Location Method for Power Cables using the Time-frequency Analysis

    Science.gov (United States)

    Kobayashi, Shin'ichi; Morimoto, Nozomi; Miyajima, Kazuhisa; Hozumi, Naohiro

    The pulse radar method is one of fault location methods for power cables. It locates the breakdown point by measuring the delay time of the echo or the discharge signal coming from the breakdown point. The equipment for the pulse radar method is more compact compared with the Murray loop bridge, and its operation is more simple because sensitive adjustments of proportion are not needed. However the signal propagating through the cable is distorted depending on the distance and frequency, leading to a poor accuracy for the location. In this report, signal processing in the time-frequency domain is proposed to solve this problem. The pulse waveforms received at two different terminals of the cable were extracted by a window function, and subsequently Fourier transformed in order to calculate the phase difference at an appropriate frequency. A special care was taken for un-wrapping the folded phase spectrum. The phase difference was interpreted as the time lag at an identical frequency. The technique was applied to the fault location for a full size XLPE cable line.

  9. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  10. Pulse Response Measurement Aiming for Locating Water Tree Degradation in XLPE Cables

    Science.gov (United States)

    Hiei, Susumu; Hozumi, Naohiro; Kurihara, Takashi; Okamoto, Tatsuki; Uchida, Katsumi; Tsuji, Taizo

    Water treeing is a degradation mode of power cable with polymeric insulation. A water tree is composed of small droplets filled with water. As the conductivity in water tree is very high, it leads to dielectric breakdown when it grows up. As inside of the water tree is filled with trap sites, it is polarized with a certain distribution of relaxation time when a DC poling voltage is applied. Although its depolarization process after removing the poling voltage is determined by ambient temperature, applying a “depolarizing voltage” with the opposite polarity can accelerate the process. If a short pulse propagating through the cable is employed as a depolarization voltage, we may locate the water tree through looking at the time-resolved pulse response. This would lead to a diagnosing method with spatial resolution. In order to retain 100 m of spatial resolution, the response should be as sharp as 1 μs. As a preliminary study, a coaxial communication cable was aged to form water trees. A DC poling voltage was applied followed by a pulse voltage with opposite polarity. The rising time of the pulse was several hundreds of microseconds. A sharp pulse current response with 50 μs in width was observed, suggesting that a rapid depolarization took place. No such response was seen when the cable specimen was not aged. We concluded that the technique is quite feasible. As the response was found to be as quick as several microseconds, an experiment using 405 m-long cable, with 5 m of degraded length in the middle, was performed. It was shown that the degraded point was successfully located.

  11. Modeling and Experiments of Spray System for Cable Painting Robot

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jia-liang; Lü Tian-sheng; LI Bei-zhi

    2008-01-01

    Many cable-stayed bridges have been built in the world in the past decades,and cable-stayed structures have been adopted in many large constructions.The cable painting robot is safe and economically efficient for stay cable maintenance.In order to satisfy the need for spraying cables in hiigh attitude,an automatic cable spray system for cable painting robots is presented in this paper.Using the βdistribution,paint thickness distribution on a cylinder surface is modeled.The spray gun's number,angle and movement are analyzed to get coat evenness.Then a robotic spray system engineering prototype has been developed,which includes a cable electric running climbing base,a spray cover,four airless spray guns and a pressurized paint container.Experiments indicate that four airless spray guns can guarantee good coat quality for general stay cables.The field tests have been successfully conducted on Nanpu Bridge,Shanghai.

  12. Brillouin distributed temperature sensing system for monitoring of submarine export cables of off-shore wind farms

    Science.gov (United States)

    Marx, Benjamin; Rath, Alexander; Kolm, Frederick; Schröder, Andreas; Buntebarth, Christian; Dreß, Albrecht; Hill, Wieland

    2016-05-01

    For high-voltage cables, the maximum temperature of the insulation must never be exceeded at any location and at any load condition. The local temperatures depend not only on the cable design and load history, but also on the local thermal environment of the cable. Therefore, distributed temperature monitoring of high-voltage cables is essential to ensure the integrity of the cable at high load. Especially, the load of the export cables of wind farms varies strongly in dependence on weather conditions. In this field study, we demonstrate the measurement performance of a new, robust Brillouin distributed temperature sensing system (Brillouin-DTS). The system is based on spontaneous Brillouin scattering and does not require a fibre loop. This is essential for long submarine high-voltage cables, where normally no loop can be formed in the seabed. It is completely passively cooled and does not contain any moving or wearing parts. The instrument is dedicated for use in industrial and other rough environments. With a measuring time below 10 min, the temperature resolution is better than 1 °C for distances up to 50 km. In the field study, the submarine export cable of an off-shore wind farm has been monitored. The temperature profile of the export cable shows several hot spots, mostly located at cable joints, and also several cold spots.

  13. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  14. Design of Experiments to Determine Causes of Flex Cable Solder Wicking, Discoloration and Hole Location Defects

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, Larry

    2009-04-22

    Design of Experiments (DoE) were developed and performed in an effort to discover and resolve the causes of three different manufacturing issues; large panel voids after Hot Air Solder Leveling (HASL), cable hole locations out of tolerance after lamination and delamination/solder wicking around flat flex cable circuit lands after HASL. Results from a first DoE indicated large panel voids could be eliminated by removing the pre-HASL cleaning. It also revealed eliminating the pre-HASL bake would not be detrimental when using a hard press pad lamination stackup. A second DoE indicated a reduction in hard press pad stackup lamination pressure reduced panel stretch in the y axis approximately 70%. A third DoE illustrated increasing the pre-HASL bake temperature could reduce delamination/solder wicking when using a soft press pad lamination stackup.

  15. Cryogenic System for a High Temperature Superconducting Power Transmission Cable

    Energy Technology Data Exchange (ETDEWEB)

    Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

    1999-07-12

    High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed.

  16. Couplings in parametrically excited inclined cables systems

    OpenAIRE

    Michon, Guilhem; Berlioz, Alain; Lamarque, Claude-Henri

    2008-01-01

    Cables in stayed bridges are subjected to important dynamic solicitations for which dynamic model are now well established. Due to their design, such structures highlight resonance phenomena and instabilities frequently observed. Nevertheless, some structures exhibit important vibration amplitudes that can not be explained simply. Measurement recently performed on a bridge point a coupling of the cable with the deck or the pillar. The present paper suggests to consider the deck flexibility co...

  17. Geostar - Navigation location system

    Science.gov (United States)

    Keyser, Donald A.

    The author describes the Radiodetermination Satellite Service (RDSS). The initial phase of the RDSS provides for a unique service enabling central offices and headquarters to obtain position-location information and receive short digital messages from mobile user terminals throughout the contiguous United States, southern Canada, and northern Mexico. The system employs a spread-spectrum, CDMA modulation technique allowing multiple customers to use the system simultaneously, without preassigned coordination with fellow users. Position location is currently determined by employing an existing radio determination receiver, such as Loran-C, GPS, or Transit, in the mobile user terminal. In the early 1990s position location will be determined at a central earth station by time-differential ranging of the user terminals via two or more geostationary satellites. A brief overview of the RDSS system architecture is presented with emphasis on the user terminal and its diverse applications.

  18. Intelligent background noise reduction technology in cable fault locator using the magneto-acoustic synchronous method

    Science.gov (United States)

    Mi, JianWei; Huang, JiFa; Fang, XiaoLi; Fan, LiBin

    2017-01-01

    The magneto-acoustic synchronous method has found wide application in accurate positioning of power cable fault due to its advantages of high accuracy and strong ability to reject interference. In the view of principle, the magneto-acoustic synchronous method needs to detect the discharge sound signal and electromagnetic signal emitted from the fault point, but the discharge sound signal is easy to be interfered by the ambient noise around and the magnetic sound synchronization. Therefore, it is challenging to quickly and accurately detect the fault location of cable especially in strong background noise environment. On the other hand, the spectral subtraction is a relatively traditional and effective method in many intelligent background noise reduction technologies, which is characterized by a relatively small computational cost and strong real-time performance. However, its application is limited because the algorithm displays poor performance in low Signal to Noise Ratio (SNR) environment. Aiming at the shortcoming of the spectral subtraction that de-noising effect is weak in low SNR environment, this paper proposes an improved spectral subtraction combining the magnetic sound synchronous principle and analyzing the properties of discharging sound. This method can accurately estimate noise in real time and optimize the performance of the basic spectral subtraction thus solving the problem that the magneto-acoustic synchronous method is unsatisfactory for positioning cable fault in the strong background noise environment.

  19. Design and development of 500 m long HTS cable system in the KEPCO power grid, Korea

    Science.gov (United States)

    Sohn, S. H.; Lim, J. H.; Yang, B. M.; Lee, S. K.; Jang, H. M.; Kim, Y. H.; Yang, H. S.; Kim, D. L.; Kim, H. R.; Yim, S. W.; Won, Y. J.; Hwang, S. D.

    2010-11-01

    In Korea, two long-term field demonstrations for high temperature superconducting (HTS) cable have been carried out for several years; Korea Electric Power Corporation (KEPCO) and LS Cable Ltd. (LSC) independently. Encouraged at the result of the projects performed in parallel, a new project targeting the real grid operation was launched in the fourth quarter of 2008 with the Korean government's financial support. KEPCO and LSC are jointly collaborating in the selection of substation, determination of cable specification, design of cryogenic system, and the scheme of protection coordination. A three phase 500 m long HTS cable at a distribution level voltage of 22.9 kV is to be built at 154/22.9 kV Icheon substation located in near Seoul. A hybrid cryogenic system reflecting the contingency plan is being designed including cryocoolers. The HTS cable system will be installed in the second quarter of 2010, being commissioned by the fall of 2010. This paper describes the objectives of the project and design issues of the cable and cryogenic system in detail.

  20. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with Ac Cables) research project. The main topics are discussed...

  1. Land cable systems for the connection of wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Brueggmann, Jan [Duisburg-Essen Univ., Duisburg (Germany). Inst. of Energy Transport and -Storage; Frisch, Walter [IFK Gesellschaft m.b.H., Salzburg (Austria). CEO

    2011-07-01

    This paper reports about the application of earth ploughs for the installation of high-voltage and extra-high-voltage cables. In the first part, there is a general description of the ploughing process with its features, the plough and the plough-cavity itself as well as some impressions of installation process. The second part analyzes the current rating of a cable system, installed by earth ploughs. Beside steady-state loads, time varying loads are assumed. The temperature profile in the soil is displayed and conclusions for the moisture content of the soil are drawn. The application of new filling materials for cables in pipes is introduced. (orig.)

  2. Cable Damage Detection System and Algorithms Using Time Domain Reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G A; Robbins, C L; Wade, K A; Souza, P R

    2009-03-24

    This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model

  3. Cable Damage Detection System and Algorithms Using Time Domain Reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G A; Robbins, C L; Wade, K A; Souza, P R

    2009-03-24

    This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model

  4. Ocean Observing using SMART subsea telecommunications cable systems

    Science.gov (United States)

    Howe, B. M.

    2015-12-01

    Planning is underway to integrate ocean sensors into SMART subsea cable systems providing basin and ultimately global array coverage within the next decades (SMART: Scientific Monitoring And Reliable Telecommunications). SMART cables will: contribute to the understanding of ocean dynamics and climate; improve knowledge of earthquakes and forecasting of tsunamis; and complement and enhance existing satellite and in-situ observing systems. SMART cables will be a first order addition to the ocean observing system, with unique contributions, strengthening and complementing satellite and in situ systems. Cables spanning the ocean basins with repeaters every ~50 km will host sensors/mini-observatories, providing power and real-time communications. The current global infrastructure of commercial submarine telecommunications cable systems consists of 1 Gm of cable with ~20,000 repeaters (to boost optical signals); the overall system is refreshed and expanded on time scales of 10 - 20 years and individual systems have lifetimes in excess of 25 years. Initial instrumentation of the cables with bottom temperature, pressure and acceleration sensors will provide unique information for monitoring and studying climate change and for improved tsunami and earthquake warning. These systems will be a new highly reliable, long-lived component of the ocean observing system, complementing satellite, float and other in situ platforms and measurements. Several UN agencies, the International Telecommunication Union, the World Meteorological Organization, and the UNESCO Intergovernmental Oceanographic Commission have formed a Joint Task Force to move this concept to fruition (ITU/WMO/IOC JTF; http://www.itu.int/en/ITU-T/climatechange/task-force-sc). A review of the overall planning effort and two NASA-funded workshops focusing on the ocean circulation and climate is presented. [Funding provided by NASA.

  5. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research......This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with AC Cables) research project. The main topics are discussed...

  6. Copper Cable Recycling System - The INEEL LSDDP Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Conner, Craig C; Meservey, Richard Harlan; Rosenberger, S.

    2001-02-01

    The United States Department of Energy (DOE) continually seeks safer and more cost-effective technologies for the deactivation and decommissioning (D&D) of nuclear facilities. The Deactivation and Decommissioning Focus Area (DDFA) and the DOE’s office of Science and Technology (OST) sponsors Large Scale Demonstration and Deployment Projects (LSDDPs). The increasing number of deactivation and decommissioning (D&D) activities at nuclear facilities can generate hundreds of tons of cables per facility consuming valuable resources such as disposal space and copper. Driven by increasing environmental concerns as well as economical pressures there is a developing need for the recycling of the uncontaminated copper. As part of the LSDDP program the NUKEM Copper Cable Recycling System (CCRS) was demonstrated November 1999 at the Idaho National Engineering and Environmental Laboratory (INEEL). This process allows recovering and recycling the uncontaminated copper contained in surface contaminated cables. The NUKEM CCRS was originally developed in Germany for the use during the D&D of commercial power plants. Up to date the CCRS has successfully processed in Germany more than 200 metric tons of contaminated cables resulting in virtually 100% free release of copper under the German standards. A total of 13.5 tons non and surrogate contaminated cables in a wide variety of sizes were successfully processed during the technology demonstration at INEEL. The assessment has demonstrated the mobility and flexibility of this new process.

  7. Development of Integrated Assessment System for Underground Power Cable Performance: A Case Study

    Science.gov (United States)

    Turan, Faiz Mohd; Johan, Kartina; Soliha Sahimi, Nur; Nor, Nik Hisyamudin Muhd

    2017-08-01

    The basic operation of any electrical machines that is catered to serve needs of civilization involves electrical power which is the main source to trigger the internal mechanism in the machines then transfer the power to other form of energy such as mechanical, light, sound and etc. The supplies of electrical does not happen just by providing the source itself, it has load carrying agent which in many cases, user would refer to it as cable. Specifically, it is the power cable which its ampacity depends significantly on the operation temperature and load stress on it. Apart from having to focus on providing improvement on improving efficiency on the source itself, power cable plays and important role because without it, current ranging from low to high could not be transmitted and hence a failure of the power system generally. Studies have conducted to discuss whether which factor contributes relatively more to the causes of power cable failure or breakdown. Such factors can be narrowed down to the three major causes which are over temperature, over voltage and stress caused by over current. Over current is one of the factor which is depends on the usage of the power system itself. The higher the usage of the power system, higher the chances of over current to take place. This will then produce load stress on the cable which eventually destroy the insulator of the cable and slowly reach the core of the cable. It is believed that an assessment method should be implemented in order to predict the performance and failure rate of the power cable and use this prediction as reference rather than just letting power failure to happen anytime unpredictable which cause huge inconvenience to users and industries. Not only do a method should be implemented, it should be as easy to be used and understood by large range of users and integrated by a graphical user interface to be used. Therefore, this research will further narrow down on the approaches to do so and the location

  8. A superconducting transformer system for high current cable testing.

    Science.gov (United States)

    Godeke, A; Dietderich, D R; Joseph, J M; Lizarazo, J; Prestemon, S O; Miller, G; Weijers, H W

    2010-03-01

    This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10,464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

  9. A new cable truss support system for coal roadways affected by dynamic pressure

    Institute of Scientific and Technical Information of China (English)

    Hong Yan; Fulian He

    2012-01-01

    The support of coal roadways is seriously affected by intense dynamic pressures.This can lead to problems with large deformation of the roof and the two side walls of coal roadways.Rapid convergence of the walls and roof,a high damage rate to the bolts and cables,or even abrupt roof collapse or rib spalling can occur during the service period of these coal roadways.Analyzing the main support measures used in China leads to a proposed new cable truss supporting system.Thorough study of the entire structure shows the superiority of this design for roadways suffering under dynamic pressure.A corresponding mechanical model of the rock surrounding the cable truss system is described in this paper and formulas for calculating pre-tightening forces of the truss cable,and the minimum anchoring forces,were deduced.The new support system was applied to a typical roadway affected by intensive dynamic pressure that is located in the Xinyuan Coal Mine.The results show that the largest subsidence of the roof was 97 mm,the convergence of the two sides was less than 248 mm,and the average depth of the loose,fractured layer was only 6.12 mm.This proves that the new support system is feasible and effective.

  10. Simple system for locating ground loops.

    Science.gov (United States)

    Bellan, P M

    2007-06-01

    A simple low-cost system for rapid identification of the cables causing ground loops in complex instrumentation configurations is described. The system consists of an exciter module that generates a 100 kHz ground loop current and a detector module that determines which cable conducts this test current. Both the exciter and detector are magnetically coupled to the ground circuit so there is no physical contact to the instrumentation system under test.

  11. 47 CFR 76.934 - Small systems and small cable companies.

    Science.gov (United States)

    2010-10-01

    ... consumer prices; (iv) The rates, as a whole, for all the cable programming, cable equipment, and cable...) The system may adjust its maximum permitted rate in accordance with the price cap requirements set... external costs, inflation or channel additions until the system has re-established initial permitted rates...

  12. Expert Locator System

    Data.gov (United States)

    US Agency for International Development — ELS is a system based out of the E3 Bureau that provides information on E3 staff, including name, contact information, geographic/sector focus, and expertise. While...

  13. Application Designs of Cable Modem System%Cable Modem系统应用设计

    Institute of Scientific and Technical Information of China (English)

    占亿民; 潘永跃; 王晖; 夏卉

    2002-01-01

    本文总结了Cable Modem系统的原理和CMTS的关键功能,系统介绍了南京电视台Cable Modem系统的设计思路和设计方法.采用源IP地址路由技术实现了用户子网划分和区分服务,并且支持基于Cable Modem系统的专网接入业务.

  14. HVAC cable systems with forced water cooling for wind energy transmission

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Zhang, Dongping [Duisburg-Essen Univ., Duisburg (DE). Dept. Energy Transport and Storage (ETS)

    2008-07-01

    This paper presents a solution for an efficient wind energy transmission onshore: HVAC cable system with forced water cooling, which provides a substantial increase of the cable ampacity without any modification of the cable construction and design. This work shows the projecting and planning of such HVAC cable systems in combination with a cooling system, especially considering the faulty (n-1)-case. The efficiency utilizing the short-term load capacity of the cable systems transmitting wind energy is shown by computations provided by specialized and adapted FEM (Finite Element Method) software. (orig.)

  15. Propylene based systems for high voltage cable insulation applications

    Energy Technology Data Exchange (ETDEWEB)

    Hosier, I L; Vaughan, A S; Swingler, S G [ECS, University of Southampton, Highfield, Southampton, SO17 1BJ (United Kingdom); Cozzarini, L, E-mail: ILH@ecs.soton.ac.u [DMRN, University of Trieste, Via Valerio 6A, 34127 Trieste (Italy)

    2009-08-01

    Crosslinked polyethylene (XLPE) remains the material of choice for extruded high voltage cables, possessing excellent thermo-mechanical and electrical properties. However, it is not easily recyclable posing questions as to its long term sustainability. Whilst both polyethylene and polypropylene are widely recycled and provide excellent dielectric properties, polypropylene has significantly better mechanical integrity at high temperatures than polyethylene. However, while isotactic polypropylene is too stiff at room temperature for incorporation into a cable system, previous studies by the authors have indicated that this limitation can be overcome by using a propylene-ethylene copolymer. Whilst these previous studies considered unrelated systems, the current study aims to quantify the usefulness of a series of related random propylene-ethylene co-polymers and assesses their potential for replacing XLPE.

  16. A cable detection lidar system for helicopters

    Science.gov (United States)

    Grossmann, Benoist; Capbern, Alain; Defour, Martin; Fertala, Remi

    1992-01-01

    Helicopters in low-level flight are endangered by power lines or telephone wires, especially when flying at night and under poor visibility conditions. In order to prevent 'wire strike', Thomson has developed a lidar system consisting of a pulsed diode laser emitting in the near infrared region (lambda = 0.9 microns). The HOWARD (Helicopter Obstacle Warning and Detection) System utilizes a high repetition rate diode laser (PRE = 20 KHz) along with counter-rotating prisms for laser beam deflection with a total field of view of 30 degrees. This system was successfully field tested in 1991. HOWARD can detect one inch wires at ranges up to 200 meters. We are presently in the process of developing a flyable compact lidar system capable of detection ranges in the order of 400 meters.

  17. Holbrook Substation Superconductor Cable System, Long Island, New York Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, James; McNamara, Joseph

    2010-06-25

    The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and

  18. Transient analysis of an HTS DC power cable with an HVDC system

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo

    2013-11-01

    The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  19. Directly modulated cable television transport systems using negative dispersion fiber

    Science.gov (United States)

    Lu, Hai-Han; Liaw, Je-Wei; Lee, Yi-Shiuan; Tsai, Wan-Lin; Ji, Yu-Jie

    2005-03-01

    A directly modulated AM-VSB cable-television transport system using negative dispersion fiber (NDF) as the transmission medium is proposed and successfully demonstrated. Good performances of carrier-to-noise radio, composite second order, and composite triple beat were obtained over a 70-km NDF transport without optical amplification. The directly modulated laser has a positive chirp, while NDF has a negative dispersion property in the transmission fiber. This negative dispersion property compensates for the laser chirp and results in a system with better transmission performance.

  20. A planar shock isolation system with high-static-low-dynamic-stiffness characteristic based on cables

    Science.gov (United States)

    Ma, Yanhui; He, Minghua; Shen, Wenhou; Ren, Gexue

    2015-12-01

    In this paper, a simple and designable shock isolation system with ideal high-static-low-dynamic-stiffness (HSLDS) is proposed, which is intended for the horizontal plane shock isolation application. In this system, the isolated object is suspended by several bearing cables and constrained by a number of uniformly distributed pretensioned cables in the horizontal plane, where the low dynamic stiffness of the system is main controlled by the pretension of the planar cables, whilst the high static stiffness is determined by the axial stiffness of the planar cables and their geometric settings. To obtain the HSLDS characteristic of the system, a brief theoretical description of the relationship between the restoring force and displacement is derived. By obtaining the three-order Taylor expansion with sufficient accuracy of the restoring force, influence of planar cable parameters on the low dynamic and high static stiffness is thus given, therefore, the required HSLDS isolator can be easily designed by adjusting the planar cable length, pretension and tensile stiffness. Finally, the isotropy characteristic of the restoring force of the system with different numbers of planar cables is investigated. To evaluate the performance of the system, a rigid isolated object and flexible cables coupling simulation model considering the contacts of the system is established by using multibody dynamics approach. In this model, flexible cables are simulated by 3-node cable element based on the absolute nodal coordinate formulation; the contact between cable and isolated object is simulated based on Hertz contact theory. Finally, the time-domain shock excitation is converted from the design shock spectrum on the basis of BV043/85 criterion. The design procedure of this isolator and some useful guidelines for choosing cable parameters are presented. In addition, a summary about the performance of the isolators with different numbers of cables shocking in an arbitrary direction is

  1. UtilityTelecom_CABLE2005

    Data.gov (United States)

    Vermont Center for Geographic Information — The VT Cable System dataset (CABLE2005) includes lines depicting the extent of Vermont's cable system as of 12/31/2005. Numerous cable companies provide service in...

  2. Cable Television: Technical Considerations in Franchising Major Market Systems.

    Science.gov (United States)

    Pilnick, Carl

    The 1972 Federal Communications Commission's (FCC) regulations on cable television were intended to assist the penetration of cable television into the large metropolitan regions of the United States. In these major market areas, the task for developing an appropriate franchise is complicated by the changing functional nature of the cable systems…

  3. 基于小波变换的电力电缆故障测距研究%Research of Power Cable Fault Location Based on Wavelet Transform

    Institute of Scientific and Technical Information of China (English)

    廖晓辉; 梁恒娜; 丁倩

    2013-01-01

    With wide application of power cable in transmission and distribution systems,the demand for cable fault location accuracy is improved.In order to locate cable fault accurately,the wavelet transform is applied in detecting the traveling wave signal of power cable.According to the principle of singularity detection of signals,the traveling wave starting pulse and reflection pulse time point is determined by searching modulus maximum,and then locating by single terminal traveling wave method for the online fault location.The experimen tal results show that the traveling wave singularity point can be detected by using localized time-frequencycharacteristic of wavelet transform,thereby the accurate time of pulse arrival is obtained.This method is not affected by fault type and the range error is small,which can achieve a higher fault location accuracy.%随着电力电缆的广泛应用,对电缆故障测距的精确度要求也日益提高.为了实现电缆故障的精确定位,引入小波变换的方法对电缆故障行波信号进行检测和分析,根据信号的奇异性检测原理,采用搜索模极大值的方法确定行波信号起始脉冲和反射脉冲时间点,应用单端行波在线故障测距方法进行测距,实验结果表明,利用小波变换的时频局部化特性可有效聚焦到电缆行波信号的奇异点,从而得到精确的脉冲到达时刻.该方法不受电缆故障类型的影响,测距误差小,可获得较高的故障定位精度.

  4. Production process for advanced space satellite system cables/interconnects.

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, Luis A.

    2007-12-01

    This production process was generated for the satellite system program cables/interconnects group, which in essences had no well defined production process. The driver for the development of a formalized process was based on the set backs, problem areas, challenges, and need improvements faced from within the program at Sandia National Laboratories. In addition, the formal production process was developed from the Master's program of Engineering Management for New Mexico Institute of Mining and Technology in Socorro New Mexico and submitted as a thesis to meet the institute's graduating requirements.

  5. Transient analysis of an HTS DC power cable with an HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@cwnu.ac.kr [Department of Electrical Engineering, Changwon National University, 9 Sarim-Dong, Changwon 641-773 (Korea, Republic of); Yang, Byeongmo [Korea Electric Power Research Institute, 105 Munji-Ro, Yuseong-Gu, Daejon 305-760 (Korea, Republic of)

    2013-11-15

    Highlights: •A model of an HTS DC power cable was developed using real time digital simulator. •The simulations of the HTS DC power cable in connection with an HVDC system were performed. •The transient analysis results of the HTS DC power cable were presented. -- Abstract: The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  6. Research of PD on-line Monitoring System for DC Cable

    Directory of Open Access Journals (Sweden)

    Duan Da-Peng

    2014-01-01

    Full Text Available In order to monitor the insulation of XLPE cable of rail system, an On-line Partial Discharge (PD Monitoring System applied for 1500V DC cables of Shanghai Traction Substation is described, including its hardware and software structure. After installed, this system successfully detected one PD signal. The results demonstrated that this system worked stably and reliably.

  7. Fiber optical cable and connector system (FOCCoS) for PFS/ Subaru

    Science.gov (United States)

    de Oliveira, Antonio Cesar; de Oliveira, Lígia Souza; de Arruda, Marcio V.; Souza Marrara, Lucas; dos Santos, Leandro H.; Ferreira, Décio; dos Santos, Jesulino B.; Rosa, Josimar A.; Junior, Orlando V.; Pereira, Jeferson M.; Castilho, Bruno; Gneiding, Clemens; Junior, Laerte S.; de Oliveira, Claudia M.; Gunn, James; Ueda, Akitoshi; Takato, Naruhisa; Shimono, Atsushi; Sugai, Hajime; Karoji, Hiroshi; Kimura, Masahiko; Tamura, Naoyuki; Wang, Shiang-Yu; Murray, Graham; Le Mignant, David; Madec, Fabrice; Jaquet, Marc; Vives, Sebastien; Fisher, Charlie; Braun, David; Schwochert, Mark; Reiley, Daniel J.

    2014-07-01

    FOCCoS, "Fiber Optical Cable and Connector System" has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition. All optical fibers from Cable C, protected by tubes, pass through the motors' bench plate, three modular plates and a strain relief box, terminating at the Tower Connector. Cable B is permanently installed at Subaru Telescope structure, as a link between Cable C and Cable A. This cable B starts at the Tower Connector device, placed on a lateral structure of the telescope, and terminates at the Gang Connector device. Cable B will be routed to minimize the compression, torsion and bending caused by the cable weight and telescope motion. In the spectrograph room, Cable A starts at the Gang Connector, crosses a

  8. Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru

    CERN Document Server

    de Oliveira, Antonio Cesar; de Arruda, Márcio V; Marrara, Lucas Souza; Santos, Leandro H dos; Ferreira, Décio; Santos, Jesulino B dos; Rosa, Josimar A; Junior, Orlando V; Pereira, Jeferson M; Castilho, Bruno; Gneiding, Clemens; Junior, Laerte S; de Oliveira, Claudia M; Gunn, James E; Ueda, Akitoshi; Takato, Naruhisa; Shimono, Atsushi; Sugai, Hajime; Karoji, Hiroshi; Kimura, Masahiko; Tamura, Naoyuki; Wang, Shiang-Yu; Murray, Graham; Mignant, David Le; Madec, Fabrice; Jaquet, Marc; Vives, Sebastien; Fisher, Charlie; Braun, David; Schwochert, Mark; Reiley, Daniel J

    2014-01-01

    FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-sta...

  9. Feasibility Study of a 270V DC Flat Cable Aircraft Electrical Power Distribution System.

    Science.gov (United States)

    1982-01-01

    POWER CABLE (27&A) 62 SPLICE ENVIRGNIMENT FIREWALL PENETRATION SPLICE I CU/2 C Fi gure 3.5.9.9 High, AmpacitY F/at Cable Replacemnt Harness InstallatiOn...NADC-82023-60 FEASIBILITY STUDY OF A.270V 0C FLAT CABLE AIRCRAFT ELECTRICAL POWER DISTRIBUTION SYSTEM SM.J. Musga R. J. Rinehart Boeing Aerospace Co...PERIOD COVEIRED FEASIBILITY STUDY OF A 270V DC FLAT CABLE Final Report AIRCRAFT ELECTRICAL POWER DISTRIBUTION SYSTEM 30 Dec. 1980 to Jan. 19824

  10. Analysis of FCL effect caused by superconducting DC cables for railway systems

    Science.gov (United States)

    Nishihara, Taichi; Hoshino, Tsutomu; Tomita, Masaru

    2017-02-01

    DC superconducting cable that is expected for railway system has been developed in the world, since the introduction effects were expected to energy saving. However, behaviour under unsteady states such as a short circuit accident are not entirely clear, and appropriate method of protection has not been established. Therefore, simulation model of the superconducting cable under direct current system was built and analyzed. Analysis result suggests the superconducting cable has the effect of Fault Current Limited (FCL) and critical current rise was effective method for temperature-rise suppression under unsteady states. Trade-off between cable temperature rise and overcurrent was confirmed.

  11. A Minicomputer Software System for Administering Interactive Instructional Programs via Two-Way Cable Television.

    Science.gov (United States)

    Zenaty, Jayne W.; And Others

    1979-01-01

    Describes a minicomputer software system for the administration of instructional programs combining interactive cable television and computer aided instruction for potentially large populations at relatively low cost. Both basic two-way cable television technology and the system developed by Michigan State University are discussed. (Author)

  12. Interactive full channel teletext system for cable television nets

    Science.gov (United States)

    Vandenboom, H. P. A.

    1984-08-01

    A demonstration set-up of an interactive full channel teletext (FCT) system for cable TV networks with two-way data communication possibilities was designed and realized. In FCT all image lines are used for teletext data lines. The FCT decoder was placed in the mini-star, and the FCT encoder which provides the FCT signal was placed in the local center. From the FCT signal a number of data lines are selected using an extra FCT decoder. They are placed on the image lines reserved for teletext so that a normal TV receiver equipped with a teletext decoder, can process the selected data lines. For texts not on hand in the FCT signal, a command can be sent to the local center via the data communication path. A cheap and simple system is offered in which the number of commanded pages or books is in principle unlimited, while the used waiting time and channel capacity is limited.

  13. Payout tension control system for reel mounted cable

    Science.gov (United States)

    Winkler, Gerhard B.

    1992-06-01

    A payout control arm is angularly displaceable about a brake shaft during payout of a cable from a storage reel in response to tensioning forces transmitted through the cable from a payout load with the cable being entrained about a pulley rotatably carried on the control arm in spaced relation to the brake shaft. Gearing drivingly connects the pulley to the brake shaft to stop payout and cause the cable to frictionally grip the pulley in response to brake engagement thereby preventing continued transmittal of tensioning forces to the reel.

  14. A 245 kV XLPE (X-Linked PolyEthylene) cable systems. 245 kV XLPE kabelsystemen

    Energy Technology Data Exchange (ETDEWEB)

    Schoonakker, P.; Willems, H.M.J. (Hoogspannings Research Laboratorium, Nederlandse Kabel Fabriek BV (NKF), Waddinxveen (Netherlands))

    1991-12-01

    High-voltage extruded cables up to and including 170 kV have acquired a good service record in the Netherlands during the last decade. These cables are rapidly replacing the conventional paper-insulated cables. The next step is the introduction of extruded cable systems for 245 kV. The Dutch Cable Factory (NKF) started the development of a 245 kV XLPE cable system several years ago. The development is based on well-defined design parameters, a controlled production, a sound test program, and a good quality control system. 12 figs., 1 tab.

  15. Application of Gliding Scaffold System In Cable-Stayed Bridge Construction

    Institute of Scientific and Technical Information of China (English)

    YU Bao-chu; ZHANG Zhe; Chang Fu-ping

    2005-01-01

    Gonghe bridge is a double level cable-stayed concrete bridge with a single-cable-plane of single cable tower. Its span is 114+120 m and a whole length of 236 m. The gliding scaffold equipment is used for the first time in the long span cable-stayed bridge construction to reduce the construction time limit. In the process of construction, to make sure a safe connection among concrete objects with different ages, the single-supporting and single-suspension system is adopted before the concrete pouring. While the double-supporting and single-suspension system is applied after concrete pouring. These construction systems with gliding scaffold equipment are first introduced in long span cable-stayed bridge and presented in detail[1]. The practice shows that these gliding scaffold systems have many advantages over the traditional ones.

  16. Design of Power Cable UAV Intelligent Patrol System Based on Adaptive Kalman Filter Fuzzy PID Control

    Directory of Open Access Journals (Sweden)

    Chen Siyu

    2017-01-01

    Full Text Available Patrol UAV has poor aerial posture stability and is largely affected by anthropic factors, which lead to some shortages such as low power cable tracking precision, captured image loss and inconvenient temperature measurement, etc. In order to solve these disadvantages, this article puts forward a power cable intelligent patrol system. The core innovation of the system is a 360° platform. This collects the position information of power cables by using far infrared sensors and carries out real-time all-direction adjustment of UAV lifting platform through the adaptive Kalman filter fuzzy PID control algorithm, so that the precise tracking of power cables is achieved. An intelligent patrol system is established to detect the faults more accurately, so that a high intelligence degree of power cable patrol system is realized.

  17. Analysis of a Liquid Nitrogen-Cooled Tri-Axial High-Temperature Superconducting Cable System

    Science.gov (United States)

    Demko, J. A.; Lue, J. W.; Gouge, M. J.; Fisher, P. W.; Lindsay, D.; Roden, M.

    2004-06-01

    This tri-axial high-temperature superconducting (HTS) cable design uses three concentric superconducting layers for the phase conductors, separated by a cold dielectric material. The design offers an efficient HTS cable configuration by reducing the amount of superconductor needed and places all three phases in a single cryostat. The tri-axial cable cooling circuit analyzed includes heat loads at the ends for the cable terminations and cable heat loads due to ac, dielectric, and thermal losses. The HTS cable critical current and ac loss are functions of the local temperature that must be determined by the analysis. The radial heat transfer also has an influence on these parameters due to the relatively low thermal conductivity of the dielectric material separating the HTS phases. The study investigates whether the tri-axial cable must be cooled both inside the former and outside of the cable. In this study, the range of operating parameters for a tri-axial HTS cable system and refrigeration requirements are determined based on expected HTS tape performance.

  18. DSBCS modulation scheme for hybrid wireless and cable television system.

    Science.gov (United States)

    Peng, P C; Wang, H Y; Chang, C H; Hu, H L; Yang, W Y; Wu, F K

    2014-01-13

    This work develops and demonstrates a double sideband with optical carrier suppression (DSBCS) modulation scheme for a hybrid wireless and cable television system based on a phase modulator (PM) and a polarization beam splitter (PBS). A carrier suppression ratio greater than 20 dB is achieved between two sidebands. In addition, the values of carrier-to-noise ratio, composite second-order and composite triple beat in various channels after 25 km of transmission are higher than the threshold value, and the power penalty of microwave signal in back-to-back and 25 km transmission perform well. Additionally, the constellation diagram of upstream signal is successfully recovered. Above results demonstrate that the proposed scheme is highly promising for practical applications.

  19. Underwater Acoustic Beacon Location System

    Science.gov (United States)

    2016-12-23

    transpose operator is a standard operator in linear or matrix algebra . The transpose operator converts the row vector   T aaaa z,y,x=P to a column...February 2017 The below identified patent application is available for licensing. Requests for information should be addressed to...300087 1 of 31 UNDERWATER ACOUSTIC BEACON LOCATION SYSTEM [0001] The present application claims the benefit of United States Provisional

  20. Study of High Voltage AC Underground Cable Systems

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Wiechowski, Wojciech T.

    2010-01-01

    High-Voltage cables are starting to be more often used to transmit electric energy at high-voltage levels, introducing in the electric grid phenomena that are uncommon when using Overhead Lines. Under the phenomena worthy of special attention are those related with the cable energisation and deen...

  1. Information Delivery Systems--The Alternative of Cable TV.

    Science.gov (United States)

    Bardwell, John

    Cable television offers great benefits in its large information carrying capacity, its local and selective character, and its two-way capability. A key fact in the history of cable television is that in 1971 the PCC required that one channel be reserved for educational use. Planning for the "wired city" has presented problems for both town…

  2. Nuclear-Hardfibre Optic Cable Assemblies for Tactical Systems,

    Science.gov (United States)

    A nuclear hard fibre optic cable assembly has been developed for the US Army FOTS(LH) programme on behalf of CECOM, Fort Monmouth. The fibre is based...built equipment. The fibre optic cable assembly is completed with expanded beam hermaphrodite connectors. An extensive qualification test programme has

  3. Microcomputer design and analysis of the cable catenary large space antenna system

    Science.gov (United States)

    Akle, W.

    1984-01-01

    The use of microcomputers in the design of a cable catenary large space antenna system is discussed. The development of a system design capability, data base utilization, systems integration, program structure and logic, and integrated graphics output are discussed.

  4. Field test and theoretical analysis of electromagnetic pulse propagation velocity on crossbonded cable systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Bak, Claus Leth; Gudmundsdottir, Unnur Stella

    2014-01-01

    In this paper, the electromagnetic pulse propagation velocity on a three-phase cable system, consisting of three single core (SC) cables in flat formation with an earth continuity conductor is under study. The propagation velocity is an important parameter for most travelling wave off- and online...

  5. CABPRO: An expert system for process planning multiwire cables. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, R.M.

    1994-04-01

    CABPRO (CABle PROcessor) is a set of computer programs using Artificial Intelligence programming to automatically generate process plans and work instructions in support of the manufacture of multiwire cables. Development of these programs required selecting appropriate hardware and software tools, defining engineering process planning activities, acquiring and representing process planning knowledge, and creating a prototype system. A successful prototype was developed and demonstrated.

  6. Method and system for controlling chemical reactions between superconductors and metals in superconducting cables

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Tengming

    2016-11-15

    A method, system, and apparatus for fabricating a high-strength Superconducting cable comprises pre-oxidizing at least one high-strength alloy wire, coating at least one Superconducting wire with a protective layer, and winding the high-strength alloy wire and the Superconducting wire to form a high-strength Superconducting cable.

  7. System and method for sub-sea cable termination

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Qin; Yin, Weijun; Zhang, Lili

    2016-04-05

    An electrical connector includes a first cable termination chamber configured to receive a first power cable having at least a first conductor sheathed at least in part by a first insulating layer and a first insulation screen layer. Also, the electrical connector includes a first non-linear resistive layer configured to be coupled to a portion of the first conductor unsheathed by at least the first insulation screen layer and configured to control a direct current electric field generated in the first cable termination chamber. In addition, the electrical connector includes a first deflector configured to be coupled to the first power cable and control an alternating current electric field generated in the first cable termination chamber.

  8. Mechanical behavior of a shelter system based on cable-strut structures

    Institute of Scientific and Technical Information of China (English)

    Jian-guo CAI; Ya ZHOU; Jian FENG; Yi-xiang XU

    2012-01-01

    A shelter system based on cable-strut structures,consisting of compressive struts and high-tensile elements,is described in this paper.The deployment of the shelter is achieved by tightening inclined cables.Lower cables are used to terminate the deployment.The state of self-stress of the cable-strut structures in the fully deployed configuration is given,and the minimum strut length and the maximum load design of the shelter are discussed.The mechanical behavior of the system was studied under symmetrical and asymmetrical load cases.The results show that the shelter in the deployed configuration satisfies the ultimate limit and the serviceability limit state conditions.Finally,the stability of the cable-strut system is investigated,considering the effect of imperfections on the buckling of the shelter.We conclude that the influence of imperfections based on the consistent imperfection mode method is not significant.

  9. Research development of digital maintenance and management system for long-span cable-stayed bridges

    Institute of Scientific and Technical Information of China (English)

    REN Yuan; HUANG Qiao; SUN Yong-ming

    2009-01-01

    Digital cable-stayed bridge maintenance and management system (DCBMS) was developed for the need of maintenance and management of long-span cable-stayed bridges. In this paper, the major functions and theoretical application of eight modules were systematically stated with the background of Harbin Songhua River cable-stayed bridge, which include data management module, inspection and measurement module, assessment module, finite element analysis module, disease diagnosis and prediction module, maintenance module, query module and help module. By analyzing and calculating the data from manual inspection database, basic database and health monitoring subsystem, DCBMS can accomplish the functions like life prediction, disease diagnosis, comprehensive assessment, maintenance and management of bridges. Therefore, the maintenance and management of long-span cable-stayed bridges can be made digital, professional and scientific. By running this system, a real-time and specific technical guidance can be provided for the maintainers and managers of longspan cable-stayed bridges.

  10. High voltage pulse cable and connector experience in the kicker systems at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Harris, K.; Artusy, M.; Donaldson, A.; Mattison, T.

    1991-05-01

    The SLAC 2-mile linear accelerator uses a wide variety of pulse kicker systems that require high voltage cable and connectors to deliver pulses from the drivers to the magnet loads. Many of the drivers in the SLAC kicker systems use cable lengths up to 80 feet and are required to deliver pulses up to 40 kV, with rise and fall time on the order of 20 ns. Significant pulse degradation from the cable and connector assembly cannot be tolerated. Other drivers are required to deliver up to 80 kV, 20 {mu}s pulses over cables 20 feet long. Several combinations of an applicable high voltage cable and matching connector have been used at SLAC to determine the optimum assembly that meets the necessary specifications and is reliable. 14 refs., 3 figs., 1 tab.

  11. The insulation coordination and surge arrester design for HTS cable system in Icheon substation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hansang, E-mail: Hansang80@korea.ac.kr [School of Railway and Electrical Engineering, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Yoon, Dong-Hee [Department of New and Renewable Energy, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Lee, Seung-Ryul [Korea Electrotechnology Research Institute, Naeson-dong, Uiwang-si, Gyeonggi-do 437-080 (Korea, Republic of); Yang, Byeong-Mo [Korea Electric Power Research Institute, Munji-dong, Yuseong-gu, Daejeon 305-760 (Korea, Republic of); Jang, Gilsoo, E-mail: gjang@korea.ac.kr [School of Electrical Engineering, Korea University, Anam-dong 5-ga, Seongbuk-gu, Seoul 136-713 (Korea, Republic of)

    2013-01-15

    Highlights: ► It is necessary to study lightning response of the HTS cable. ► The analytic model has been developed for the HTS cable in the Icheon substation. ► Well-designed surge arrester has been verified through PSCAD/EMTDC simulations. -- Abstract: This paper proposes an insulation coordination and surge arrester design for HTS (High-Temperature Superconducting) cable system in Icheon substation in Korea. In the aspect of the economic analysis, since the HTS cable is very expensive, the insulation coordination to prevent the dielectric breakdown caused by the lightning surge should be considered carefully. Also, in the aspect of the power system reliability, since the HTS cable has much more capacity compared than conventional power cables and the ripple effect from the HTS cable failure may lead to the wide area blackout, an intensive study for insulation coordination from lightning surge is one of the most important considerations. In this paper, the insulation coordination for lightning surge is verified using HTS cable and power equipment models and the design of the proper surge arrester is proposed.

  12. Analysis and prevention of accident-caused faults in power cable lines

    Directory of Open Access Journals (Sweden)

    Susakova Tatyana V.

    2017-01-01

    Full Text Available To ensure fault-free operation of power cable lines it is essential to make a thorough analysis of the type of faults and their location. The paper considers the most common type of faults and main reasons for cable damage. The case study of cable faults at an urban network (Zabaikalsky Krai shows that the root cause is insulation deterioration, especially with the cables reaching the end of their 35 year lifetime. Therefore, to prevent faults and mitigate the threats it is necessary to increase surveillance of cable systems and use cables with higher reliability and functionality, e.g., XLPE cables.

  13. Development of cable fed flash X-ray (FXR) system

    Science.gov (United States)

    Menon, Rakhee; Mitra, S.; Patel, A. S.; Kumar, R.; Singh, G.; Senthil, K.; Kumar, Ranjeet; Kolge, T. S.; Roy, Amitava; Acharya, S.; Biswas, D.; Sharma, Archana

    2017-08-01

    Flash X-ray sources driven by pulsed power find applications in industrial radiography, and a portable X-ray source is ideal where the radiography needs to be taken at the test site. A compact and portable flash X-ray (FXR) system based on a Marx generator has been developed with the high voltage fed to the FXR tube via a cable feed-through arrangement. Hard bremsstrahlung X-rays of few tens of nanosecond duration are generated by impinging intense electron beams on an anode target of high Z material. An industrial X-ray source is developed with source size as low as 1 mm. The system can be operated from 150 kV to 450 kV peak voltages and a dose of 10 mR has been measured at 1 m distance from the source window. The modeling of the FXR source has been carried out using particle-in-cell and Monte Carlo simulations for the electron beam dynamics and X-ray generation, respectively. The angular dose profile of X-ray has been measured and compared with the simulation.

  14. Investigation of Tension Forces in A Stay Cable System of A Road Bridge Using Vibration Methods

    Directory of Open Access Journals (Sweden)

    Hawryszków Paweł

    2015-01-01

    Full Text Available In the article author presents method of investigation of tension forces in stay cable systems using dynamical methods. Research was carried out during stay cable system installation on WN-24 viaduct near Poznań, that is way it was possible to compare tension forces indicated directly by devices using for tensioning of cable-stayed bridges with results achieved indirectly by means of dynamical methods. Discussion of results was presented. Advantages of dynamical methods and possible fields of application was described. This method, which has been rarely used before, may occur interesting alternative in diagnostics of bridges in comparison to traditional methods.

  15. Magnetohydrodynamic (MHD) nuclear weapons effects on submarine cable systems. Volume 1. Experiments and analysis. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1987-06-01

    This report presents a study of the nuclear weapons magnetohydrodynamic (MHD) effects on submarine communications cables. The study consisted of the analysis and interpretation of currently available data on submarine cable systems TAT-4, TAT-6, and TAT-7. The primary result of the study is that decrease of the effective resistivity with frequency over the available experimental range, coupled with the model results, leads to quite small effective resistivities at the MHD characteristic frequencies, and hence small earth potential differences. Thus, it appears that submarine cable systems are less susceptible to an MHD threat than their land-based counter-parts.

  16. ICE Online Detainee Locator System

    Data.gov (United States)

    Department of Homeland Security — The Online Detainee Locator datasets provide the location of a detainee who is currently in ICE custody, or who was release from ICE custody for any reason with the...

  17. A Cable-Passive Damper System for Sway and Skew Motion Control of a Crane Spreader

    Directory of Open Access Journals (Sweden)

    La Duc Viet

    2015-01-01

    Full Text Available While the crane control problem is often approached by applying a certain active control command to some parts of the crane, this paper proposes a cable-passive damper system to reduce the vibration of a four-cable suspended crane spreader. The residual sway and skew motions of a crane spreader always produce the angle deflections between the crane cables and the crane spreader. The idea in this paper is to convert those deflections into energy dissipated by the viscous dampers, which connect the cables and the spreader. The proposed damper system is effective in reducing spreader sway and skew motions. Moreover, the optimal damping coefficient can be found analytically by minimizing the time integral of system energy. The numerical simulations show that the proposed passive system can assist the input shaping control of the trolley motion in reducing both sway and skew responses.

  18. Non destructive testing of medium and high voltage cables with a transportable radiography system

    OpenAIRE

    2010-01-01

    A power cable is the most important part in a power transmission system. The cables must be total quality dedicated andcertified for development, manufacturing and installation, however are exposed to a corrosive environment. The purpose ofthis paper is to show that the fast neutron radiography with a transportable system is a solution to find defects in the cablesand reduce the cost of inspection. The design, regarding the materials considered, was compatible with the European UnionDirective...

  19. The Design of Partial Discharge On-Line Monitoring System for XLPE Power Cable

    OpenAIRE

    Chen Rui-Long; Qian Yong; Ye Hai-Feng; Sheng Ge-Hao; Jiang Xiu-Chen

    2013-01-01

    Partial discharge detection is an important means to assess the situation of XLPE power cable’s insulation. This study has developed an on-line monitoring system which applies to the medium voltage XLPE cable on partial discharge, described its working principle, components of hardware, software designing and program implementation in details. Through monitoring the partial discharge signal in grounding lines of the XLPE cable’s shield, the system integrated assess the situation of XLPE cable...

  20. Limit span of self-anchored cable-stayed suspension cooperation system bridge based on strength

    Institute of Scientific and Technical Information of China (English)

    Zhe ZHANG; Huili WANG; Sifeng QIN; Xiaomeng GE

    2009-01-01

    The limit span of self-anchored cable-stayed suspension bridge is deduced. The relations among the geometrical parameters, loads and material characteristics are also analyzed. Based on the material strength and commonly used materials, the limit spans of self-anchored cable-stayed suspension bridges with concrete girder or steel girder under vertical static load are discussed in detail.The corresponding upper limit spans and the effect of the factors on the span are given. The results indicate that increasing rise-span ratio, height-span ratio and cable-stayed segment length or reducing the second dead load could increase the cooperation system span.

  1. LONG TERM OPERATION ISSUES FOR ELECTRICAL CABLE SYSTEMS IN NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Dr Leonard S [Pacific Northwest National Laboratory (PNNL); Duckworth, Robert C [ORNL; Glass III, Dr. Samuel W. [Pacific Northwest National Laboratory (PNNL)

    2016-01-01

    Nuclear power plants contain hundreds of kilometers of electrical cables including cables used for power, for instrumentation, and for control. It is essential that safety-related cable systems continue to perform following a design-basis event. Wholesale replacement of electrical cables in existing plants facing licensing period renewal is both impractical and cost-prohibitive. It is therefore important to understand the long term aging of cable materials to have confidence that aged cables will perform when needed. It is equally important in support of cable aging management to develop methods to evaluate the health of installed cables and inform selective cable replacement decisions. The most common insulation materials for electrical cables in nuclear power plants are cross-linked polyethylene and ethylene-propylene rubber. The mechanical properties of these materials degrade over time in the presence of environmental stresses including heat, gamma irradiation, and moisture. Mechanical degradation of cable insulation beyond a certain threshold is unacceptable because it can lead to insulation cracking, exposure of energized conductors, arcing and burning or loss of the ability of the cable system to function during a design-basis accident. While thermal-, radiation-, and moisture-related degradation of polymer insulation materials has been extensively studied over the last few decades, questions remain regarding the long-term performance of cable materials in nuclear plant-specific environments. Identified knowledge gaps include an understanding of the temperature-dependence of activation energies for thermal damage and an understanding of the synergistic effects of radiation and thermal stress on polymer degradation. Many of the outstanding questions in the aging behavior of cable materials relate to the necessity of predicting long-term field degradation using accelerated aging results from the laboratory. Materials degrade faster under more extreme

  2. SC Power leads and cables - Nominal Current Test Performance of 2 kA-Class High-Tc Superconducting Cable Conductors and Its Implications for Cooling Systems for Utility Cables

    DEFF Research Database (Denmark)

    Willen, D. W. A; Daumling, M.; Rasmussen, C. N.

    2000-01-01

    at high currents. The critical currents of these conductors are in the range of 1-3 kA, and ac losses smaller than 1 W/m are measured at 2 kArms. AC currents with peak values exceeding the dc critical currents are applied. Increased losses, in excess of the expected magnitization losses are observed when...... individual layers in the cables saturate. The loss-contributions from other components of the cable system are discussed,and the implications for the cooling apparatus for superconducting utility cables are determined....

  3. The Application of Geographic Information System on Telecommunication Cable Management System

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Geographic Information System (GIS) is a computer system tomanage the geographically distributed data. It combines the process of geographic informat ion and attribute information. Telecommunication bureau has great requirements f or GIS and corresponding software platforms due to the speciality of the telecom m unication system. The design ideas, solutions and basic functions of the telecommunication GIS for the cable design and maintenance are discussed .

  4. A fiber-optical cable television system using a reflective semiconductor optical amplifier

    Science.gov (United States)

    Peng, P. C.; Shiu, K. C.; Liu, W. C.; Chen, K. J.; Lu, H. H.

    2013-02-01

    This investigation demonstrates a fiber-optical cable television system using a reflective semiconductor optical amplifier (RSOA) for uplink transmission. The downstream signal is cable television and the upstream signal is generated by remodulating the downstream signal via an RSOA with a radio-frequency signal. Favorable carrier-to-noise ratio, composite second-order, and composite triple beat are obtained for the downstream and the upstream signal is successfully transmitted over 60 km of single-mode fiber.

  5. Simulation of cutting process in the cable recycling system

    Science.gov (United States)

    Li, Yang; Luo, Zhen; Song, Kailei; Ao, Sansan; Wang, Rui

    2011-05-01

    The utilization of Waste Electrical and Electronic Equipment is a hot spot in environmental protection field presently and the resource utilization of cable wastes is an important subject. An enormous amount of electrical cable is disposed of as scrap each year. In order to recycle the valuable copper wires, cable granulator technique is used widely. However, one of the shortcomings of this technique is it has serious tool wear. In order to better understand the reason for tool wear, this paper simulates the stress and strain distribution in the cutting tool and copper during the cutting process in cable granulator by finite element method. The result shows that a tensile stress region, which is the main reason for blade tipping, appeared in the upper blade. Besides, the tensile stress in the right side of upper blade is higher than that in the left side. Therefore, in order to extend the life of cutter, we suggest using different materials in different stress zone to manufacture cutting tool. After the cutter was worn out, the right side of the blade can be renovated using material with well tensile performance through overlaying welding, as well as the left side of the blade can be renovated by material with high red hardness, high wear resistance, and high compression strength through overlaying welding. This method can reduce the consumption of precious metals and raise the utilization rate of materials.

  6. Space charge accumulation in polymeric high voltage DC cable systems

    NARCIS (Netherlands)

    Bodega, R.

    2006-01-01

    One of the intrinsic properties of the polymeric high voltage (HV) direct current (DC) cable insulation is the accumulation of electrostatic charges. Accumulated charges distort the initial Laplacian distribution of the electric field, leading to a local field enhancement that may cause insulation d

  7. UtilityTelecom_CABLE2013

    Data.gov (United States)

    Vermont Center for Geographic Information — The VT Cable dataset (CABLE2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013 in addition to those companies who do...

  8. Dynamics analysis of planar armored cable motion in deep-sea ROV system

    Institute of Scientific and Technical Information of China (English)

    全伟才; 张竺英; 张艾群

    2014-01-01

    The armored cable used in a deep-sea remotely operated vehicle (ROV) may undergo large displacement motion when subjected to dynamic actions of ship heave motion and ocean current. A novel geometrically exact finite element model for two-dimensional dynamic analysis of armored cable is presented. This model accounts for the geometric nonlinearities of large displacement of the armored cable, and effects of axial load and bending stiffness. The governing equations are derived by consistent linearization and finite element discretization of the total weak form of the armored cable system, and solved by the Newmark time integration method. To make the solution procedure avoid falling into the local extreme points, a simple adaptive stepping strategy is proposed. The presented model is validated via actual measured data. Results for dynamic configurations, motion and tension of both ends of the armored cable, and resonance-zone are presented for two numerical cases, including the dynamic analysis under the case of only ship heave motion and the case of joint action of ship heave motion and ocean current. The dynamics analysis can provide important reference for the design or product selection of the armored cable in a deep-sea ROV system so as to improve the safety of its marine operation under the sea state of 4 or above.

  9. Onshore continuation of bipolar cable systems for bulk wind power transmission

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Brueggmann, Jan; Stammen, Joerg [Duisburg-Essen Univ., Duisburg (Germany). Dept. of Electrical Engineering

    2009-07-01

    Offshore windfarms have to be connected to the onshore grid by means of high voltage submarine cables. Typical windfarms (pilot-phase) may have an installed power of 400 MW. Several windfarms can be arranged to a cluster with a common grid connection which has to be designed for e.g. 2000 MW. For such tasks of bulk power transmission, the HVAC bipolar cable system was proposed. By use of three 245 kV bipolar four-core submarine cables, the desired 2000 MW can be transmitted over distances of more than 150 km. Hence, HVAC bipolar systems offer an efficient bulk power transmission with flexibility in installation and operation. Onshore, such connections have to find a continuation by use of land cables. In order to enable extreme transmission capacities, cable routes are analysed, which are equipped with standard 245 kV single-core XLPE-cables in bipolar configurations and with special, thermally improved backfill. Time varying loads and partially dried-out soil are considered. (orig.)

  10. Test-based approach to cable tray support system analysis and design: Behavior and test methods

    Energy Technology Data Exchange (ETDEWEB)

    Reigles, Damon G., E-mail: dreigles@engnovex.com [engNoveX, Inc., 19C Trolley Square, Wilmington, DE 19806 (United States); Brachmann, Ingo; Johnson, William H. [Bechtel Nuclear, Security & Environmental, 12011 Sunset Hills Rd, Suite 110, Reston, VA 20190 (United States); Gürbüz, Orhan [Tobolski Watkins Engineering, Inc., 4125 Sorrento Valley Blvd, Suite B, San Diego, CA 92121 (United States)

    2016-06-15

    Highlights: • Describes dynamic response behavior of unistrut type cable tray supports. • Summarizes observations from past full-scale shake table test programs. • Outlines testing methodologies necessary to identify key system parameters. - Abstract: Nuclear power plant safety-related cable tray support systems subjected to seismic loadings were originally understood and designed to behave as linear elastic systems. This behavioral paradigm persisted until the early 1980s when, due to evolution of regulatory criteria, some as-installed systems needed to be qualified to higher seismic motions than originally designed for. This requirement prompted a more in-depth consideration of the true seismic response behavior of support systems. Several utilities initiated extensive test programs, which demonstrated that trapeze strut-type cable tray support systems exhibited inelastic and nonlinear response behaviors with plastic hinging at the connections together with high damping due to bouncing of cables in the trays. These observations were used to demonstrate and justify the seismic adequacy of the aforementioned as-installed systems. However, no formalized design methodology or criteria were ever established to facilitate use of these test data for future evaluations. This paper assimilates and reviews the various test data and conclusions for the purpose of developing a design methodology for the seismic qualification of safety-related cable tray support systems.

  11. Dynamic Simulation and Tension Compensation Research on Subsea Umbilical Cable Laying System

    Institute of Scientific and Technical Information of China (English)

    Guojun Bi; Shaohua Zhu; Jun Liu; Xiaoming Fang; Liquan Wang

    2013-01-01

    For studying the dynamic performance of subsea umbilical cable laying system and achieving the goal of cable tension and laying speed control, the rigid finite element method is used to discrete and transform the system into a rigid-flexible coupling multi-body system which consists of rigid elements and spring-damping elements. The mathematical model of subsea umbilical cable laying system kinematic chain is presented with the second order Lagrange equation in the joint coordinate system, and dynamic modeling and simulation is performed with ADAMS. The dynamic analysis is conducted assuming the following three statuses:ideal laying, practical laying under wave disturbance, and practical laying with tension compensation. Results show that motion disturbances of the laying budge under sea waves, especially with heaving and pitching, will cause relatively serious fluctuations in cable tension and laying speed. Tension compensation, i.e., active back tension torque control can restrict continuous tension increasing or decreasing effectively and rapidly, thus avoiding cable breach or buckling.

  12. Dynamic simulation and tension compensation research on subsea umbilical cable laying system

    Science.gov (United States)

    Bi, Guojun; Zhu, Shaohua; Liu, Jun; Fang, Xiaoming; Wang, Liquan

    2013-12-01

    For studying the dynamic performance of subsea umbilical cable laying system and achieving the goal of cable tension and laying speed control, the rigid finite element method is used to discrete and transform the system into a rigid-flexible coupling multi-body system which consists of rigid elements and spring-damping elements. The mathematical model of subsea umbilical cable laying system kinematic chain is presented with the second order Lagrange equation in the joint coordinate system, and dynamic modeling and simulation is performed with ADAMS. The dynamic analysis is conducted assuming the following three statuses: ideal laying, practical laying under wave disturbance, and practical laying with tension compensation. Results show that motion disturbances of the laying budge under sea waves, especially with heaving and pitching, will cause relatively serious fluctuations in cable tension and laying speed. Tension compensation, i.e., active back tension torque control can restrict continuous tension increasing or decreasing effectively and rapidly, thus avoiding cable breach or buckling.

  13. Cable Television: Franchising Considerations.

    Science.gov (United States)

    Baer, Walter S.; And Others

    This volume is a comprehensive reference guide to cable television technology and issues of planning, franchising, and regulating a cable system. It is intended for local government officials and citizens concerned with the development of cable television systems in their communities, as well as for college and university classes in…

  14. Cable Television: Franchising Considerations.

    Science.gov (United States)

    Baer, Walter S.; And Others

    This volume is a comprehensive reference guide to cable television technology and issues of planning, franchising, and regulating a cable system. It is intended for local government officials and citizens concerned with the development of cable television systems in their communities, as well as for college and university classes in…

  15. Privacy Preserving Location Proof Updating System

    Directory of Open Access Journals (Sweden)

    Dhinesh Kumar S.

    2015-11-01

    Full Text Available Location-sensitive service broadcasting on user’s mobile devices to discover the current location. A privacy preserving Location proof updating system(APPLAUS,which does not rely on the wide deployement of network infrastructure or the expensive trusted computing module.In APPLAUS, Bluetooth enabled mobile devices in range mutually generate location proofs,which are uploaded to a untrusted location proof. An authorized verifier can query and retrieve location proofs from the server.Moreover,our location proof system guarantees user location privacy from every party.Bluetooth enabled mobile devices in range mutually generate location proofs.CA used to be the bridges between the verifier and the location proof server.

  16. Privacy Preserving Location Proof Updating System

    Directory of Open Access Journals (Sweden)

    Dhinesh Kumar S.

    2014-03-01

    Full Text Available Location-sensitive service broadcasting on user’s mobile devices to discover the current location. A privacy preserving Location proof updating system(APPLAUS,which does not rely on the wide deployement of network infrastructure or the expensive trusted computing module.In APPLAUS, Bluetooth enabled mobile devices in range mutually generate location proofs,which are uploaded to a untrusted location proof. An authorized verifier can query and retrieve location proofs from the server.Moreover,our location proof system guarantees user location privacy from every party.Bluetooth enabled mobile devices in range mutually generate location proofs.CA used to be the bridges between the verifier and the location proof server..

  17. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    are to be found. One very good example of this is offshore wind power plants. The current transmission system is laid out in a traditional manner, which is based on the idea of not transporting power over longer distances as the power plants have been located near centres of consumption. It has merely played....... Many interesting research topics are still open, especially with regards to asset management tools....

  18. Research on communication system of underground safety management based on leaky feeder cable

    Institute of Scientific and Technical Information of China (English)

    CHEN Jian-hong; ZHANG Tao; CHENG Yun-cai; ZHANG Han

    2007-01-01

    According to the current working status of underground safety management and production scheduling, the importance and existed problem of underground mine radio communication were summarized, and the basic principle and classification of leaky feeder cable were introduced and the characteristics of cable were analyzed specifically in depth, and the application model of radio communication system for underground mine safety management was put forward. Meanwhile, the research explanation of the system component, function and evaluation was provided. The discussion result indicates that communication system of underground mine safety management which is integrated two-way relay amplifier and other equipment has many communication functions, and underground mine mobile communication can be achieved well.

  19. Analytical and numerical construction of equivalent cables.

    Science.gov (United States)

    Lindsay, K A; Rosenberg, J R; Tucker, G

    2003-08-01

    The mathematical complexity experienced when applying cable theory to arbitrarily branched dendrites has lead to the development of a simple representation of any branched dendrite called the equivalent cable. The equivalent cable is an unbranched model of a dendrite and a one-to-one mapping of potentials and currents on the branched model to those on the unbranched model, and vice versa. The piecewise uniform cable, with a symmetrised tri-diagonal system matrix, is shown to represent the canonical form for an equivalent cable. Through a novel application of the Laplace transform it is demonstrated that an arbitrary branched model of a dendrite can be transformed to the canonical form of an equivalent cable. The characteristic properties of the equivalent cable are extracted from the matrix for the transformed branched model. The one-to-one mapping follows automatically from the construction of the equivalent cable. The equivalent cable is used to provide a new procedure for characterising the location of synaptic contacts on spinal interneurons.

  20. Energy conservation research of dehumidification system for main cable anticorrosion of suspension bridge

    Institute of Scientific and Technical Information of China (English)

    Chen Ce; Fan Liangkai; Feng Zhaoxiang; Pen Guanzhong

    2011-01-01

    The necessity of the main cable anticorrosion for suspension bridge is described, and operating principles and composition of main cable dehumidification system are analyzed. An idea using the waste heat of high temperature outlet air of dehumidification system to heat up regeneration air of rotary-type dehumidifier is put forward in this paper. The concrete scheme is to install a heat exchanger on air-out pipeline of roots blower and air-in pipeline of regeneration electric heater of rotary dehumidifier. Air preheated by the heat exchanger enters regeneration electric heater of rotary-type dehumidifier. Energy conservation of main cable dehumidification system for the Yangtze River highway bridge is calculated, and the results show that energy conservation rate can reach 44 %.

  1. Field Test and Simulation of a 400 kV Cross-Bonded Cable System

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Gustavsen, Bjørn; Bak, Claus Leth

    2011-01-01

    for measurements on a 400 kV cable system with cross bonded sheaths. The paper describes in detail the modeling procedure for the cable system and compares simulation results with the transient field test results. It is shown that although the main characteristics of the waveforms are well reproduced...... in the initial transient, there are significant deviations between the simulation and measurement results. An analysis indicates that the main cause for the deviation is inadequate representation of the current distribution on conductors as the modeling approach does not take into account proximity effects...

  2. Cable television monitoring system based on fiber laser and FBG sensor

    Science.gov (United States)

    Peng, Peng-Chun; Huang, Jun-Han; Wu, Shin-Shian; Yang, Wei-Yuan; Shen, Po-Tso

    2015-05-01

    We propose and experimentally demonstrate a cable television monitoring system based on a linear-cavity fiber laser and fiber Bragg grating (FBG) sensors. The linear-cavity fiber laser comprises a hybrid amplifier with an erbium-doped fiber amplifier and a semiconductor optical amplifier, a fiber loop mirror with a polarization controller and an optical coupler as a cavity mirror, and the FBG sensors acting as another cavity mirrors. Experimental results showed the feasibility of the monitoring system with sufficient of signal-to-noise ratio over 30 dB and stable output power, and the link of cable television signals on fiber link can monitored in real time. Excellent performances of carrier-to-noise ratio after long-distance transmission are obtained for cable television applications.

  3. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  4. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  5. HTS Transmission Cable System for installation in the Long Island Power Grid

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Frank [American Superconductor Corporation, Devens, MA (United States); Durand, Fabien [American Superconductor Corporation, Devens, MA (United States); Maguire, James [American Superconductor Corporation, Devens, MA (United States)

    2015-10-05

    Department of Energy (DOE) Award DE-FC26-07NT43240 was issued on October 1, 2007. Referred to as LIPA2, the principal objectives of the project were to develop key components required to deploy and demonstrate second-generation (2G) high temperature superconductor (HTS) cables in a 600 meter (2000 feet) underground segment of a 138kV three-phase transmission circuit of the Long Island Power Authority (LIPA) power grid. A previous effort under DOE Award DE-FC36-03GO13032 (referred to as LIPA1) resulted in installation (and subsequent successful operation) of first-generation (1G) HTS cables at the LIPA site. As with LIPA1, American Superconductor (AMSC) led the effort for LIPA2 and was responsible for overall management of the project and producing sufficient 2G wire to fabricate the required cable. Nexans' tasks included design/manufacture/installation of the cable, joint (splice), cable terminations and field repairable cryostat; while work by Air Liquide involved engineering and installation support for the refrigeration system modifications.

  6. Installation of seafloor cabled seismic and tsunami observation system developed by using ICT

    Science.gov (United States)

    Shinohara, Masanao; Yamada, Tomoaki; Sakai, Shin'ichi; Shiobara, Hajime; Kanazawa, Toshihiko

    2017-04-01

    A seafloor cabled system is useful for study of earth science and disaster mitigation, because real-time and long-term observation can be performed. Therefore seafloor cabled systems with seismometers and tsunami-meters have been used over the past 25 years around Japan. Because increase of a number of sensors is needed, a new system with low costs for production, deployment and operation is expected. In addition, the new system should have sufficient for flexibility of measurements after installation. To achieve these demands, we started development of a new system using Information and Communication Technologies (ICT) for data transmission and system control. The new system can be made compact since software processes various measurements. Reliability of the system is kept by using redundant system which is easily constructed using the ICT. The first system based on this concept was developed as Ocean Bottom Cabled Seismometer (OBCS) system and deployed in Japan Sea. Development of the second system started from 2012. The Ocean Bottom Cabled Seismometer and Tsunami-meter (OBCST) system has both seismometers and tsunami-meters. Each observation node has a CPU and FPGAs. The OBCST system uses standard TCP/IP protocol with a speed of 1 Gbps for data transmission, system control and monitoring. IEEE-1588 (PTP) is implemented to synchronize a real-time clock, and accuracy is less than 300 ns. We developed two types of observation node. One equips a pressure gauge as tsunami sensor, and another has an external port for additional observation sensor using PoE. Deployment of the OBCST system was carried out in September 2015 by using a commercial telecommunication cable ship. The noise levels at the OBCST system are comparable to those at the existing cabled system off Sanriku. It is found that the noise levels at the OBCST system are low at frequencies greater than 2 Hz and smaller than 0.1 Hz. This level of ambient seismic noise is close to a typical system noise. From

  7. Power transmission cable development for the Space Station Freedom electrical power system

    Science.gov (United States)

    Schmitz, Gregory V.; Biess, John J.

    1989-01-01

    Power transmission cable is presently being evaluated under a NASA Lewis Research Center advanced development contract for application in the Space Station Freedom (SSF) electrical power system (EPS). Evaluation testing has been performed by TRW and NASA Lewis Research Center. The results of this development contract are presented. The primary cable design goals are to provide (1) a low characteristic inductance to minimize line voltage drop at 20 kHz, (2) electromagnetic compatibility control of the 20-kHz ac power current, (3) a physical configuration that minimizes ac resistance and (4) release of trapped air for corona-free operation.

  8. Elastin Cables Define the Axial Connective Tissue System in the Murine Lung.

    Science.gov (United States)

    Wagner, Willi; Bennett, Robert D; Ackermann, Maximilian; Ysasi, Alexandra B; Belle, Janeil; Valenzuela, Cristian D; Pabst, Andreas; Tsuda, Akira; Konerding, Moritz A; Mentzer, Steven J

    2015-11-01

    The axial connective tissue system is a fiber continuum of the lung that maintains alveolar surface area during changes in lung volume. Although the molecular anatomy of the axial system remains undefined, the fiber continuum of the lung is central to contemporary models of lung micromechanics and alveolar regeneration. To provide a detailed molecular structure of the axial connective tissue system, we examined the extracellular matrix of murine lungs. The lungs were decellularized using a 24 hr detergent treatment protocol. Systematic evaluation of the decellularized lungs demonstrated no residual cellular debris; morphometry demonstrated a mean 39 ± 7% reduction in lung dimensions. Scanning electron microscopy (SEM) demonstrated an intact structural hierarchy within the decellularized lung. Light, fluorescence, and SEM of precision-cut lung slices demonstrated that alveolar duct structure was defined by a cable line element encased in basement membrane. The cable line element arose in the distal airways, passed through septal tips and inserted into neighboring blood vessels and visceral pleura. The ropelike appearance, collagenase resistance and anti-elastin immunostaining indicated that the cable was an elastin macromolecule. Our results indicate that the helical line element of the axial connective tissue system is composed of an elastin cable that not only defines the structure of the alveolar duct, but also integrates the axial connective tissue system into visceral pleura and peripheral blood vessels.

  9. 47 CFR 76.905 - Standards for identification of cable systems subject to effective competition.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Standards for identification of cable systems subject to effective competition. 76.905 Section 76.905 Telecommunication FEDERAL COMMUNICATIONS... cognizable investment if the sum of the interests other than those held by or through “passive investors”...

  10. Line Differential Protection Scheme Modelling for Underground 420 kV Cable Systems

    DEFF Research Database (Denmark)

    Sztykiel, Michal; Bak, Claus Leth; Dollerup, Sebastian

    2011-01-01

    Based on the analysis of a specific relay model and an HVAC (High Voltage Alternating Current) cable system, a detailed approach to EMTDC/PSCAD modelling of protective relays is presented. Such approach allows to create complex and accurate relay models derived from the original algorithms. Relay...

  11. Line Differential Protection Scheme Modelling for Underground 420 kV Cable Systems

    DEFF Research Database (Denmark)

    Sztykiel, Michal; Bak, Claus Leth; Wiechowski, Wojciech

    2010-01-01

    Based on the analysis of a specific relay model and an HVAC (High Voltage Alternating Current) cable system, a new approach to EMTDC/PSCAD modelling of protective relays is presented. Such approach allows to create complex and accurate relay models derived from the original algorithms. Relay mode...

  12. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Science.gov (United States)

    2010-10-01

    ... signal. (ii) For all other TV interface devices, 346.4 times the square root of (R) for the video signal... devices must be designed to: (i) Distribute multiple television signals at the same time; (ii) Distribute... demonstrated with a radio frequency input signal of 0 to 25 dBmV. (e) For cable system terminal devices and...

  13. Power System Technical Performance Issues Related to the Application of Long HVAC Cables

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    The aim of this TB is to serve as a practical guide for preparing models and performing studies necessary during the assessment of the technical performance of HV/EHV systems with a large share of (long) AC cables. The brochure follows all phases of planning and analysis of a typical underground...

  14. Submarine Optical Fiber Cable Systems for High Speed Growth Developments in Optical Communication Networks

    Directory of Open Access Journals (Sweden)

    Ahmed Nabih Zaki Rashed

    2012-07-01

    Full Text Available Optical Submarine Cable systems play a principal role in international telecommunications, thanks to their superiority over satellite systems in terms of stability, latency and upgradability. The business of constructing and then maintaining and selling capacity over submarine fiber optic cables is fascinating, and is absolutely fundamental to modern day communications. The sector has its own unique challenges due to the extraordinarily rapid pace of development in transmission technologies as well as the timescales and levels of investment required to build new systems. In the present paper, ultimate optical transmission of ultra multi channels huge submarine cables under different depth conditions has been investigated over wide range of the affecting parameters. The double impact of both temperature and pressure is also analyzed. We have employed multiplexing technique namely UW-WDM to be merged number of 10000 transmitted channels on the same submarine optical transmission links respectively. Based on experimental data, both the deep ocean water temperature and pressure are tailored as functions of the water depth. The product of the transmitted bit rate and the repeater spacing is processed over wide ranges of the affecting parameters. As well as we have taken into account the estimation of the total cost planning and transmission data rate capacity of the submarine fiber cable system for this multiplexing technique under study.

  15. Power System Technical Performance Issues Related to the Application of Long HVAC Cables

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    The aim of this TB is to serve as a practical guide for preparing models and performing studies necessary during the assessment of the technical performance of HV/EHV systems with a large share of (long) AC cables. The brochure follows all phases of planning and analysis of a typical underground ...

  16. Wi-Fi real time location systems

    Science.gov (United States)

    Doll, Benjamin A.

    This thesis objective was to determine the viability of utilizing an untrained Wi-Fi. real time location system as a GPS alternative for indoor environments. Background. research showed that GPS is rarely able to penetrate buildings to provide reliable. location data. The benefit of having location information in a facility and how they might. be used for disaster or emergency relief personnel and their resources motivated this. research. A building was selected with a well-deployed Wi-Fi infrastructure and its. untrained location feature was used to determine the distance between the specified. test points and the system identified location. It was found that the average distance. from the test point throughout the facility was 14.3 feet 80% of the time. This fell within. the defined viable range and supported that an untrained Wi-Fi RTLS system could be a. viable solution for GPS's lack of availability indoors.

  17. Location Systems An Introduction to the Technology Behind Location Awareness

    CERN Document Server

    LaMarca, Anthony

    2008-01-01

    Advances in electronic location technology and the coming of age of mobile computing have opened the door for location-aware applications to permeate all aspects of everyday life. Location is at the core of a large number of high-value applications ranging from the life-and-death context of emergency response to serendipitous social meet-ups. For example, the market for GPS products and services alone is expected to grow to US200 billion by 2015. Unfortunately, there is no single location technology that is good for every situation and exhibits high accuracy, low cost, and universal coverage.

  18. Cryogenic helium gas circulation system for advanced characterization of superconducting cables and other devices

    Science.gov (United States)

    Pamidi, Sastry; Kim, Chul Han; Kim, Jae-Ho; Crook, Danny; Dale, Steinar

    2012-04-01

    A versatile cryogenic test bed, based on circulating cryogenic helium gas, has been designed, fabricated, and installed at the Florida State University Center for Advanced Power Systems (FSU-CAPS). The test bed is being used to understand the benefits of integrating the cryogenic systems of multiple superconducting power devices. The helium circulation system operates with four sets of cryocooler and heat exchanger combinations. The maximum operating pressure of the system is 2.1 MPa. The efficacy of helium circulation systems in cooling superconducting power devices is evaluated using a 30-m-long simulated superconducting cable in a flexible cryostat. Experiments were conducted at various mass flow rates and a variety of heat load profiles. A 1-D thermal model was developed to understand the effect of the gas flow parameters on the thermal gradients along the cable. Experimental results are in close agreement with the results from the thermal model.

  19. Integrated system of structural health monitoring and intelligent management for a cable-stayed bridge.

    Science.gov (United States)

    Chen, Bin; Wang, Xu; Sun, Dezhang; Xie, Xu

    2014-01-01

    It is essential to construct structural health monitoring systems for large important bridges. Zhijiang Bridge is a cable-stayed bridge that was built recently over the Hangzhou Qiantang River (the largest river in Zhejiang Province). The length of Zhijiang Bridge is 478 m, which comprises an arched twin-tower space and a twin-cable plane structure. As an example, the present study describes the integrated system of structural health monitoring and intelligent management for Zhijiang Bridge, which comprises an information acquisition system, data management system, evaluation and decision-making system, and application service system. The monitoring components include the working environment of the bridge and various factors that affect bridge safety, such as the stress and strain of the main bridge structure, vibration, cable force, temperature, and wind speed. In addition, the integrated system includes a forecasting and decision-making module for real-time online evaluation, which provides warnings and makes decisions based on the monitoring information. From this, the monitoring information, evaluation results, maintenance decisions, and warning information can be input simultaneously into the bridge monitoring center and traffic emergency center to share the monitoring data, thereby facilitating evaluations and decision making using the system.

  20. Identification of aeroelastic forces on bridge cables from full-scale measurements

    DEFF Research Database (Denmark)

    Acampora, Antonio; Macdonald, J.H.G.; Georgakis, Christos

    2011-01-01

    Despite much research in recent years, large amplitude vibrations of inclined cables continue to be of concern for cable-stayed bridges. Various mechanisms have been suggested for their excitation, including rain-wind excitation, dry inclined cable galloping, high reduced velocity vortex shedding...... Bridge. The system records wind conditions and weather conditions, as well as accelerations of certain cables and a few locations on the deck and tower. Using state-of-the-art methods of output-only system identification, the vibration modes of the cables have been identified. From these modes...

  1. Identification of aeroelastic forces on bridge cables from full-scale measurements

    DEFF Research Database (Denmark)

    Acampora, Antonio; Macdonald, J.H.G.; Georgakis, Christos

    2011-01-01

    Despite much research in recent years, large amplitude vibrations of inclined cables continue to be of concern for cable-stayed bridges. Various mechanisms have been suggested for their excitation, including rain-wind excitation, dry inclined cable galloping, high reduced velocity vortex shedding...... Bridge. The system records wind conditions and weather conditions, as well as accelerations of certain cables and a few locations on the deck and tower. Using state-of-the-art methods of output-only system identification, the vibration modes of the cables have been identified. From these modes...

  2. Study on 10 kVDC powered junction box for a cabled ocean observatory system

    Science.gov (United States)

    Chen, Yan-hu; Yang, Can-jun; Li, De-jun; Jin, Bo; Chen, Ying

    2013-04-01

    A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with 1 Gigabit/sec Ethernet communication, can be transmitted from the shore to the seafloor through an umbilical armored cable. A subsea junction box is fixed at a cable terminal, enabling the extension of up to nine connections. The box consists of three main pressure vessels that perform power conversion, power distribution, and real-time communication functions. A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments. A power distribution system and an Ethernet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station, respectively. Specific validations of all sections were qualified in a laboratory environment prior to the sea trial. The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test. The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations.

  3. Study on 10 kVDC Powered Junction Box for A Cabled Ocean Observatory System

    Institute of Scientific and Technical Information of China (English)

    CHEN Yan-hu; YANG Can-jun; LI De-jun; JIN Bo; CHEN Ying

    2013-01-01

    A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed.A 10 kV direct current (kVDC) with up to 10 kW power,along with 1 Gigabit/sec Ethemet communication,can be transmitted from the shore to the seafloor through an umbilical armored cable.A subsea junction box is fixed at a cable terminal,enabling the extension of up to nine connections.The box consists of three main pressure vessels that perform power conversion,power distribution,and real-time communication functions.A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments.A power distribution system and an Ethernet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station,respectively.Specific validations of all sections were qualified in a laboratory environnent prior to the sea trial.The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test.The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations.

  4. Smart monitoring system based on adaptive current control for superconducting cable test

    Energy Technology Data Exchange (ETDEWEB)

    Arpaia, Pasquale [Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125 Napoli (Italy); Technology Department, European Organization for Nuclear Research (CERN), 1217 Geneva (Switzerland); Ballarino, Amalia; Montenero, Giuseppe [Technology Department, European Organization for Nuclear Research (CERN), 1217 Geneva (Switzerland); Daponte, Vincenzo [Technology Department, European Organization for Nuclear Research (CERN), 1217 Geneva (Switzerland); Department of Electronics, Information, and Bioengineering, Polytechnic of Milan, 20133 Milano (Italy); Svelto, Cesare [Department of Electronics, Information, and Bioengineering, Polytechnic of Milan, 20133 Milano (Italy)

    2014-12-15

    A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, “Performance improvement of a measurement station for superconducting cable test,” Rev. Sci. Instrum.83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.

  5. Smart monitoring system based on adaptive current control for superconducting cable test.

    Science.gov (United States)

    Arpaia, Pasquale; Ballarino, Amalia; Daponte, Vincenzo; Montenero, Giuseppe; Svelto, Cesare

    2014-12-01

    A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, "Performance improvement of a measurement station for superconducting cable test," Rev. Sci. Instrum. 83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.

  6. Practical Applications of Cables and Ropes in the ISS Countermeasures System

    Science.gov (United States)

    Moore, Cherice; Svetlik, Randall; Williams, Antony

    2017-01-01

    As spaceflight durations have increased over the last four decades, the effects of weightlessness on the human body are far better understood, as are the countermeasures. A combination of aerobic and resistive exercise devices contribute to countering the losses in muscle strength, aerobic fitness, and bone strength of today's astronauts and cosmonauts that occur during their missions on the International Space Station. Creation of these systems has been a dynamically educational experience for designers and engineers. The ropes and cables in particular have experienced a wide range of challenges, providing a full set of lessons learned that have already enabled improvements in on-orbit reliability by initiating system design improvements. This paper examines the on-orbit experience of ropes and cables in several exercise devices and discusses the lessons learned from these hardware items, with the goal of informing future system design.

  7. Non destructive testing of medium and high voltage cables with a transportable radiography system

    Directory of Open Access Journals (Sweden)

    D. V. Bandekas

    2010-01-01

    Full Text Available A power cable is the most important part in a power transmission system. The cables must be total quality dedicated andcertified for development, manufacturing and installation, however are exposed to a corrosive environment. The purpose ofthis paper is to show that the fast neutron radiography with a transportable system is a solution to find defects in the cablesand reduce the cost of inspection. The design, regarding the materials considered, was compatible with the European UnionDirective on “Restriction of Hazardous Substances” (RoHS 2002/95/EC, hence excluding the use of cadmium and lead.Wide width values for the collimator ratio were calculated. With suitable collimator design it was possibly to optimize theneutron radiography parameters. Finally the shielding design was examined closely. The proposed system has been simulatedusing the MCNPX code.

  8. 400 MW grid connection to the Anholt offshore wind farm in a single 220 kV cable system

    Energy Technology Data Exchange (ETDEWEB)

    Kvarts, Thomas [Energinet.dk (Denmark); Bailleul, March; Douima, Youssef; Petitot, Francois [General Cable Group, Silec, Cachan (France); Domingo, Jose M. [General Cable Group (Spain); Jensen, Anders; Salwin, Sven T. [nkt cables (Denmark)

    2011-07-01

    In 2012, the so far largest wind farm in Denmark, Anholt offshore wind farm, will bring 400 MW more electrical power to Denmark. To that effect, Energinet.dk, Denmark's transmission system operator, will install and operate an 85-km-long grid connection from the Anholt platform to the Danish electricity transmission grid. This connection is composed of: (1) a single 24 km 245 kV submarine, 3 core cable, delivered and installed by nkt cables, and (2) a 60 km 245 kV underground cable system, delivered by the General Cable group. (3) an offshore transformer platform. (4) reactive compensation and transformation onshore. This aim of this paper is to present the characteristics of this project, the first at 245 kV in Denmark, and one of the first 245 kV 3 core submarine cables worldwide. We will first discuss the reasons that prevailed in defining the link's design: routes, voltage, cables dimensioning, impact of capitalized losses etc. Then, the submarine and underground cable systems' characteristics and necessary type test are presented. Finally, we present an overview of the actual implementation of each solution. (orig.)

  9. Service Water System Inspection Locator (SWSIL)

    Energy Technology Data Exchange (ETDEWEB)

    Pytel, M.L.; Tang, S.S.; Carney, C.E.; Licina, G.J. (Structural Integrity Associates, Inc., San Jose, CA (United States))

    1993-04-01

    Inspection and maintenance of a service water system is a key to reliable system operation. As emphasized by NRC Generic Letter 89-13, service water system reliability in nuclear plants must by assured since the SWS may support safety related equipment The diversity of design, water chemistry, and operating regimens, coupled with the tremendous size of these systems (literally miles of piping and hundreds of heat exchangers) makes the selection of locations to be inspected a difficult chore. In cooperation with the Electric Power Research Institute (EPRI) and the New York Power Authority (NYPA), a Service Water System Inspection Locator (SWSIL) has been developed to explore the feasibility of using an expert system to evaluate the corrosion susceptibility of the thousands of locations and components associated with nuclear service water systems (SWS). Such an expert system provides utilities with a method for planning and prioritizing inspections. SWSIL, Version 1.0, has been applied to the emergency diesel generator service water cooling loop of the emergency service water (ESW) system of the James A. FitzPatrick plant. The feasibility demonstration described in this report provided a framework for applying SWSIL to a system of any size. The demonstration also showed that refinement of the plant data input interface and flow modeling are required. Applicability of SWSIL in its current configuration to large systems is limited and awaits these improvements.

  10. Attenuation of fibrosis with selective inhibition of c-Abl by siRNA in systemic sclerosis dermal fibroblasts.

    Science.gov (United States)

    Karimizadeh, Elham; Motamed, Nasrin; Mahmoudi, Mahdi; Jafarinejad-Farsangi, Saeideh; Jamshidi, Ahmadreza; Faridani, Habibeh; Gharibdoost, Farhad

    2015-03-01

    Cellular abelson (c-Abl), a non-receptor tyrosine kinase, is an important molecule in the pathogenesis of systemic sclerosis. There have been reports of beneficial effects of pharmacological tyrosine kinase inhibitors, such as imatinib mesylate, on fibrosis. However, these inhibitors affect multiple tyrosine kinases including c-Abl, c-kit, and platelet-derived growth factor receptor. The effects of selective inhibition of c-Abl using small interfering RNA (siRNA) on dermal fibrosis have not yet been explored. The aim of this study is to evaluate whether specific inhibition of c-Abl by siRNA can influence the transforming growth factor-β1 (TGF-β1)-induced fibrotic responses. Dermal fibroblasts from systemic sclerosis patients and healthy controls were transfected with c-Abl siRNA. The expression levels of collagen type I, fibronectin, connective tissue growth factor (CTGF), and α-smooth muscle actin (α-SMA) were measured at both the mRNA and protein levels in the absence or presence of TGF-β1 pro-fibrotic cytokine. In healthy dermal fibroblasts, the expression of collagen type 1, fibronectin, α-SMA, and CTGF mRNAs and proteins that were upregulated after stimulation with TGF-β1 was markedly decreased by c-Abl siRNA. Silencing of c-Abl via siRNA efficiently reduced the basal synthesis of collagen type I, fibronectin, α-SMA, and CTGF mRNAs and proteins in systemic sclerosis fibroblasts, but it had no effect on the baseline expression of these genes and proteins in healthy dermal fibroblasts. In conclusion, specific c-Abl gene silencing using siRNA effectively reduced fibrosis-related gene expression. Inhibition of c-Abl by siRNA may be a potential therapeutic approach for fibrotic diseases such as systemic sclerosis.

  11. Feasibility study of superconducting power cables for DC electric railway feeding systems in view of thermal condition at short circuit accident

    Science.gov (United States)

    Kumagai, Daisuke; Ohsaki, Hiroyuki; Tomita, Masaru

    2016-12-01

    A superconducting power cable has merits of a high power transmission capacity, transmission losses reduction, a compactness, etc., therefore, we have been studying the feasibility of applying superconducting power cables to DC electric railway feeding systems. However, a superconducting power cable is required to be cooled down and kept at a very low temperature, so it is important to reveal its thermal and cooling characteristics. In this study, electric circuit analysis models of the system and thermal analysis models of superconducting cables were constructed and the system behaviors were simulated. We analyzed the heat generation by a short circuit accident and transient temperature distribution of the cable to estimate the value of temperature rise and the time required from the accident. From these results, we discussed a feasibility of superconducting cables for DC electric railway feeding systems. The results showed that the short circuit accident had little impact on the thermal condition of a superconducting cable in the installed system.

  12. Assessment of 69 kV Underground Cable Thermal Ratings using Distributed Temperature Sensing

    Science.gov (United States)

    Stowers, Travis

    Underground transmission cables in power systems are less likely to experience electrical faults, however, resulting outage times are much greater in the event that a failure does occur. Unlike overhead lines, underground cables are not self-healing from flashover events. The faulted section must be located and repaired before the line can be put back into service. Since this will often require excavation of the underground duct bank, the procedure to repair the faulted section is both costly and time consuming. These added complications are the prime motivators for developing accurate and reliable ratings for underground cable circuits. This work will review the methods by which power ratings, or ampacity, for underground cables are determined and then evaluate those ratings by making comparison with measured data taken from an underground 69 kV cable, which is part of the Salt River Project (SRP) power subtransmission system. The process of acquiring, installing, and commissioning the temperature monitoring system is covered in detail as well. The collected data are also used to evaluate typical assumptions made when determining underground cable ratings such as cable hot-spot location and ambient temperatures. Analysis results show that the commonly made assumption that the deepest portion of an underground power cable installation will be the hot-spot location does not always hold true. It is shown that distributed cable temperature measurements can be used to locate the proper line segment to be used for cable ampacity calculations.

  13. Development and Improvement of an Intelligent Cable Monitoring System for Underground Distribution Networks Using Distributed Temperature Sensing

    OpenAIRE

    Jintae Cho; Jae-Han Kim; Hak-Ju Lee; Ju-Yong Kim; Il-Keun Song; Joon-Ho Choi

    2014-01-01

    With power systems switching to smart grids, real-time and on-line monitoring technologies for underground distribution power cables have become a priority. Most distribution components have been developed with self-diagnostic sensors to realize self-healing, one of the smart grid functions in a distribution network. Nonetheless, implementing a real-time and on-line monitoring system for underground distribution cables has been difficult because of high cost and low sensitivity. Nowadays, opt...

  14. Design, construction, and operation of an actively controlled deep-sea CO2 enrichment experiment using a cabled observatory system

    Science.gov (United States)

    Kirkwood, William J.; Walz, Peter M.; Peltzer, Edward T.; Barry, James P.; Herlien, Robert A.; Headley, Kent L.; Kecy, Chad; Matsumoto, George I.; Maughan, Thom; O'Reilly, Thomas C.; Salamy, Karen A.; Shane, Farley; Brewer, Peter G.

    2015-03-01

    We describe the design, testing, and performance of an actively controlled deep-sea Free Ocean CO2 Enrichment (dp-FOCE) system for the execution of seafloor experiments relating to the impacts of ocean acidification on natural ecosystems. We used the 880 m deep MARS (Monterey Accelerated Research System) cable site offshore Monterey Bay, California for this work, but the Free Ocean CO2 Enrichment (FOCE) system concept is designed to be scalable and can be modified to be used in a wide variety of ocean depths and locations. The main frame is based on a flume design with active thruster control of flow and a central experimental chamber. The unit was allowed to free fall to the seafloor and connected to the cable node by remotely operated vehicle (ROV) manipulation. For operation at depth we designed a liquid CO2 containment reservoir which provided the CO2 enriched working fluid as ambient seawater was drawn through the reservoir beneath the more buoyant liquid CO2. Our design allowed for the significant lag time associated with the hydration of the dissolved CO2 molecule, resulting in an e-folding time, τ, of 97 s between fluid injection and pH sensing at the mean local T=4.31±0.14 °C and pHT of 7.625±0.011. The system maintained a pH offset of ~0.4 pH units compared to the surrounding ocean for a period of ~1 month. The unit allows for the emplacement of deep-sea animals for testing. We describe the components and software used for system operation and show examples of each. The demonstrated ability for active control of experimental systems opens new possibilities for deep-sea biogeochemical perturbation experiments of several kinds and our developments in open source control systems software and hardware described here are applicable to this end.

  15. Cable Tester Box

    Science.gov (United States)

    Lee, Jason H.

    2011-01-01

    Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

  16. KGS Based Control for Parking Brake Cable Manufacturing System

    OpenAIRE

    Geeta Khare; R.S. Prasad

    2011-01-01

    In today’s competitive production environment, process industries, demand a totally integrated control and optimization solution that can increase productivity, reliability and quality while minimizing cost. Automation is a step beyond mechanization. For automation of production plant either centralized or distributed control system are used. There are standardized approaches and standard hardware & software available worldwide as per the requirement. Investment in process control system is a...

  17. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    , and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program......A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface...

  18. Electrical power cable engineering

    CERN Document Server

    Thue, William A

    2011-01-01

    Fully updated, Electrical Power Cable Engineering, Third Edition again concentrates on the remarkably complex design, application, and preparation methods required to terminate and splice cables. This latest addition to the CRC Press Power Engineering series covers cutting-edge methods for design, manufacture, installation, operation, and maintenance of reliable power cable systems. It is based largely on feedback from experienced university lecturers who have taught courses on these very concepts.The book emphasizes methods to optimize vital design and installation of power cables used in the

  19. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  20. Cable historical operating temperature estimator

    Energy Technology Data Exchange (ETDEWEB)

    Leon de, F.; St-Roch, P.; Beauregard, C. [Cyme International, St-Bruno, PQ (Canada)

    2006-07-01

    A tool designed to accurately determine the thermal age of underground cables was described. The cable historical operating temperature estimate (CHOTE) is a software application designed to identify which cables have exceeded their normal and emergency operating temperatures. CHOTE is also capable of predicting when cables are likely to reach their maximum design temperature in the future. The system operates by processing archived loading information from data acquisition systems in order to automatically analyze all the thermal sections of a system. Cables that exceed their emergency and normal temperatures for the longest amount of time are ranked first, and outputs display when and where the hot spots have occurred. CHOTE is also able to study the impact of the addition of new cables and to determine the remaining ampacity of cables installed in a given duct bank. It was concluded that the CHOTE system can help in the efficient management of cable repairs and installations. 28 refs., 7 figs.

  1. Power system technical performance issues related to the application of long HVAC cables

    DEFF Research Database (Denmark)

    Wiechowski, on behalf of Cigre WG C4.502, W.; Sluis, L. V. der; Ohno, Teruo

    2011-01-01

    This paper reports the progress of work of Cigre Working Group C4.502 “Power system technical performance issues related to the application of long HVAC cables”. The primary goal of the WG C4.502 is to write a technical brochure that will serve as practical guide for performing studies necessary...... for assessing the technical performance of HV/EHV systems with large share of AC cable lines. This paper besides providing a background for formulation of WG C4.502 and its overall aim, describes the tasks that were accomplished before the interim report was submitted to Study Committee C4 System Technical...

  2. Power System Technical Performance Issues related to the Application of Long HVAC Cables

    DEFF Research Database (Denmark)

    Wiechowski, W.; der Sluis, L.V.; Ohno, Teruo

    2011-01-01

    This paper reports the progress of work of Cigre Working Group C4.502 “Power system technical performance issues related to the application of long HVAC cables”. The primary goal of the WG C4.502 is to write a technical brochure that will serve as practical guide for performing studies necessary...... for assessing the technical performance of HV/EHV systems with large share of AC cable lines. This paper besides providing a background for formulation of WG C4.502 and its overall aim, describes the tasks that were accomplished before the interim report was submitted to Study Committee C4 System Technical...

  3. A Ku-band satellite system for the cable television industry

    Science.gov (United States)

    Napoli, Joseph

    This paper describes the satellite requirements for the Ku-band used for satellite delivery of television programming. The case for using the Ku-band is reviewed, including the business benefits to the cable industry, the superior protection against failure, the pace of technical advances, and the channel capacity. The characteristics of the satellites carrying the Ku-band are described, and a protection plan for the satellites is considered. The technical characteristics of the Ku-band and related systems considerations are addressed. Signal outage at the Ku-band is discussed, and Ku-band receiving system design is examined, including system installation and operations.

  4. Design of optical fiber cable television distribution systems using erbium-doped fiber amplifiers

    Science.gov (United States)

    Zhang, Jian-Guo; Sharma, A. B.; Ritthisoonthorn, Pichet

    1998-04-01

    Optical fiber distribution systems with intensity- modulation/direct-detection and erbium-doped fiber amplifiers are designed for cable television (CATV) applications. Two types of system configurations are considered, i.e., the passive power splitter with optically preamplified receivers (PPS-OPR) scheme and the hybrid passive-and-active power splitter (HPAPS) scheme. The receiver sensitivity is calculated for various system parameters. We compare both schemes through the number of CATV subscribers and show that the HPAPS scheme is superior to the PPS-OPR scheme for large- scale CATV distribution applications.

  5. The Design of Partial Discharge On-Line Monitoring System for XLPE Power Cable

    Directory of Open Access Journals (Sweden)

    Chen Rui-Long

    2013-09-01

    Full Text Available Partial discharge detection is an important means to assess the situation of XLPE power cable’s insulation. This study has developed an on-line monitoring system which applies to the medium voltage XLPE cable on partial discharge, described its working principle, components of hardware, software designing and program implementation in details. Through monitoring the partial discharge signal in grounding lines of the XLPE cable’s shield, the system integrated assess the situation of XLPE cable’s insulation. The results of running show that the system is stable and reliable.

  6. 一种光缆故障定位方法研究%Study on the method of fault location for a fiber optic cable

    Institute of Scientific and Technical Information of China (English)

    马小平; 朱杰

    2015-01-01

    With mobile transmission network becomes more and more huge, maintenance, network security is particularly important, this paper from the specific maintenance technical point of view proposed a practical cable fault location method, to solve the problem of resource model and the fiber core monitoring data exchange technology convergence, effectively improve the fault handling efficiency.%随着移动传输网络的日趋庞大,维护网络安全尤其重要,本文从具体维护技术角度,提出了一种实用的光缆故障定位方法,解决了资源模型和纤芯监测数据互通技术中衔接的问题,有效提高了故障处理效率.

  7. Research on Power Cable Fault Location Based on Traveling Wave Method and Wavelet Transform%基于小波变换和行波法的电缆故障测距方法研究

    Institute of Scientific and Technical Information of China (English)

    于泽; 费明

    2011-01-01

    To find out the singularity of the high coefficients of fault signal, the method of searching modulus maxima is adopted and realized the precise rangefinder fault. Through the simulation platform of MATLAB, the power cable fault system simulation model is established and obtaind the cable faults fluctuations in the end. The relative error of different locations of the different faults simulation data is less than 4% , that shows that this method is feasible and accuracy.. At the same time a kind range finder formula is put forward and developed that doesn' t include wave velocity v. That makes the calculation of the fault distance to dispense the affect from wave velocity theoretically.%采用搜索模极大值的方法,进而实现故障的精确测距.通过MATLAB仿真平台,建立了电力电缆故障系统的仿真模型,得出电缆故障波形图.不同位置的不同故障的仿真数据相对误差均小于4%,验证了该方法的可行性和准确性.同时提出并推导一种不包含波速v的测距公式,使得在计算故障距离从理论上摆脱了波速对测距结果的影响.

  8. Power and Submarine Cable Systems for the KM3NeT kilometre cube Neutrino Telescope

    CERN Document Server

    Sedita, M; Hallewell, G

    2009-01-01

    The KM3NeT EU-funded consortium, pursuing a cubic kilometre scale neutrino telescope in the Mediterranean Sea, is developing technical solutions for the construction of this challenging project, to be realized several kilometres below the sea level. In this framework a proposed DC/DC power system has been designed, maximizing reliability and minimizing difficulties and expensive underwater activities. The power conversion, delivery, transmission and distribution network will be described with particular attention to: the main electro-optical cable, on shore and deep sea power conversion, the subsea distribution network and connection systems, together with installation and maintenance issues.

  9. Computational analysis of nonlinearities within dynamics of cable-based driving systems

    Science.gov (United States)

    Anghelache, G. D.; Nastac, S.

    2017-08-01

    This paper deals with computational nonlinear dynamics of mechanical systems containing some flexural parts within the actuating scheme, and, especially, the situations of the cable-based driving systems were treated. It was supposed both functional nonlinearities and the real characteristic of the power supply, in order to obtain a realistically computer simulation model being able to provide very feasible results regarding the system dynamics. It was taken into account the transitory and stable regimes during a regular exploitation cycle. The authors present a particular case of a lift system, supposed to be representatively for the objective of this study. The simulations were made based on the values of the essential parameters acquired from the experimental tests and/or the regular practice in the field. The results analysis and the final discussions reveal the correlated dynamic aspects within the mechanical parts, the driving system, and the power supply, whole of these supplying potential sources of particular resonances, within some transitory phases of the working cycle, and which can affect structural and functional dynamics. In addition, it was underlines the influences of computational hypotheses on the both quantitative and qualitative behaviour of the system. Obviously, the most significant consequence of this theoretical and computational research consist by developing an unitary and feasible model, useful to dignify the nonlinear dynamic effects into the systems with cable-based driving scheme, and hereby to help an optimization of the exploitation regime including a dynamics control measures.

  10. Superconductor cable

    Science.gov (United States)

    Allais, Arnaud; Schmidt, Frank; Marzahn, Erik

    2010-05-04

    A superconductor cable is described, having a superconductive flexible cable core (1) , which is laid in a cryostat (2, 3, 4), in which the cable core (1) runs in the cryostat (2, 3, 4) in the form of a wave or helix at room temperature.

  11. Flat conductor cable commercialization project

    Science.gov (United States)

    Hogarth, P.; Wadsworth, E.

    1977-01-01

    An undercarpet flat conductor cable and a baseboard flat conductor cable system were studied for commercialization. The undercarpet system is designed for use in office and commercial buildings. It employs a flat power cable, protected by a grounded metal shield, that terminates in receptacles mounted on the floor. It is designed to interface with a flat conductor cable telephone system. The baseboard system consists of a flat power cable mounted in a plastic raceway; both the raceway and the receptacles are mounted on the surface of the baseboard. It is designed primarily for use in residential buildings, particularly for renovation and concrete and masonry construction.

  12. Modelling, Simulation and Testing of a Reconfigurable Cable-Based Parallel Manipulator as Motion Aiding System

    Directory of Open Access Journals (Sweden)

    Gianni Castelli

    2010-01-01

    Full Text Available This paper presents results on the modelling, simulation and experimental tests of a cable-based parallel manipulator to be used as an aiding or guiding system for people with motion disabilities. There is a high level of motivation for people with a motion disability or the elderly to perform basic daily-living activities independently. Therefore, it is of great interest to design and implement safe and reliable motion assisting and guiding devices that are able to help end-users. In general, a robot for a medical application should be able to interact with a patient in safety conditions, i.e. it must not damage people or surroundings; it must be designed to guarantee high accuracy and low acceleration during the operation. Furthermore, it should not be too bulky and it should exert limited wrenches after close interaction with people. It can be advisable to have a portable system which can be easily brought into and assembled in a hospital or a domestic environment. Cable-based robotic structures can fulfil those requirements because of their main characteristics that make them light and intrinsically safe. In this paper, a reconfigurable four-cable-based parallel manipulator has been proposed as a motion assisting and guiding device to help people to accomplish a number of tasks, such as an aiding or guiding system to move the upper and lower limbs or the whole body. Modelling and simulation are presented in the ADAMS environment. Moreover, experimental tests are reported as based on an available laboratory prototype.

  13. Field Test and Simulation of a 400 kV Cross-Bonded Cable System

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Gustavsen, Bjørn; Bak, Claus Leth

    2011-01-01

    This paper discusses cable modeling for long high voltage AC underground cables. In investigating the possibility of using long cables instead of overhead lines, the simulation results must be trustworthy. Therefore, model validation is of great importance. This paper gives a benchmark case...

  14. Research on Far-Field Wavelet's Extraction and Application of Vertical Cable System

    Science.gov (United States)

    Wang, Xiangchun; Xiao, Qingsong; Xia, Changliang; Wu, Zhongliang; Xie, Chengliang

    2017-03-01

    In marine seismic exploration, ghost wave and bubble effect reduce the vertical resolution and interpretation accuracy seriously. Here firstly the far-field wavelet including source wavelet, ghost wave and bubble effect recorded by the vertical cable system (VCS) is extracted. Then, filters are designed using the extracted far-field wavelet to eliminate ghost wave, bubble effect and source wavelet. At last, the designed filters are applied to the seismic data of VCS. The results show that this method can eliminate ghost wave, bubble effect and source wavelet effectively and the vertical resolution of the seismic data is improved obviously.

  15. Intelligent geocoding system to locate traffic crashes.

    Science.gov (United States)

    Qin, Xiao; Parker, Steven; Liu, Yi; Graettinger, Andrew J; Forde, Susie

    2013-01-01

    State agencies continue to face many challenges associated with new federal crash safety and highway performance monitoring requirements that use data from multiple and disparate systems across different platforms and locations. On a national level, the federal government has a long-term vision for State Departments of Transportation (DOTs) to report state route and off-state route crash data in a single network. In general, crashes occurring on state-owned or state maintained highways are a priority at the Federal and State level; therefore, state-route crashes are being geocoded by state DOTs. On the other hand, crashes occurring on off-state highway system do not always get geocoded due to limited resources and techniques. Creating and maintaining a statewide crash geographic information systems (GIS) map with state route and non-state route crashes is a complicated and expensive task. This study introduces an automatic crash mapping process, Crash-Mapping Automation Tool (C-MAT), where an algorithm translates location information from a police report crash record to a geospatial map and creates a pinpoint map for all crashes. The algorithm has approximate 83 percent mapping rate. An important application of this work is the ability to associate the mapped crash records to underlying business data, such as roadway inventory and traffic volumes. The integrated crash map is the foundation for effective and efficient crash analyzes to prevent highway crashes.

  16. Feasibility Study on Tension Estimation Technique for Hanger Cables Using the FE Model-Based System Identification Method

    Directory of Open Access Journals (Sweden)

    Kyu-Sik Park

    2015-01-01

    Full Text Available Hanger cables in suspension bridges are partly constrained by horizontal clamps. So, existing tension estimation methods based on a single cable model are prone to higher errors as the cable gets shorter, making it more sensitive to flexural rigidity. Therefore, inverse analysis and system identification methods based on finite element models are suggested recently. In this paper, the applicability of system identification methods is investigated using the hanger cables of Gwang-An bridge. The test results show that the inverse analysis and systemic identification methods based on finite element models are more reliable than the existing string theory and linear regression method for calculating the tension in terms of natural frequency errors. However, the estimation error of tension can be varied according to the accuracy of finite element model in model based methods. In particular, the boundary conditions affect the results more profoundly when the cable gets shorter. Therefore, it is important to identify the boundary conditions through experiment if it is possible. The FE model-based tension estimation method using system identification method can take various boundary conditions into account. Also, since it is not sensitive to the number of natural frequency inputs, the availability of this system is high.

  17. Development and Improvement of an Intelligent Cable Monitoring System for Underground Distribution Networks Using Distributed Temperature Sensing

    Directory of Open Access Journals (Sweden)

    Jintae Cho

    2014-02-01

    Full Text Available With power systems switching to smart grids, real-time and on-line monitoring technologies for underground distribution power cables have become a priority. Most distribution components have been developed with self-diagnostic sensors to realize self-healing, one of the smart grid functions in a distribution network. Nonetheless, implementing a real-time and on-line monitoring system for underground distribution cables has been difficult because of high cost and low sensitivity. Nowadays, optical fiber composite power cables (OFCPCs are being considered for communication and power delivery to cope with the increasing communication load in a distribution network. Therefore, the application of distributed temperature sensing (DTS technology on OFCPCs used as underground distribution lines is studied for the real-time and on-line monitoring of the underground distribution power cables. Faults can be reduced and operating ampacity of the underground distribution system can be increased. This paper presents the development and improvement of an intelligent cable monitoring system for the underground distribution power system, using DTS technology and OFCPCs as the underground distribution lines in the field.

  18. Final Report: MaRSPlus Sensor System Electrical Cable Management and Distributed Motor Control Computer Interface

    Science.gov (United States)

    Reil, Robin

    2011-01-01

    The success of JPL's Next Generation Imaging Spectrometer (NGIS) in Earth remote sensing has inspired a follow-on instrument project, the MaRSPlus Sensor System (MSS). One of JPL's responsibilities in the MSS project involves updating the documentation from the previous JPL airborne imagers to provide all the information necessary for an outside customer to operate the instrument independently. As part of this documentation update, I created detailed electrical cabling diagrams to provide JPL technicians with clear and concise build instructions and a database to track the status of cables from order to build to delivery. Simultaneously, a distributed motor control system is being developed for potential use on the proposed 2018 Mars rover mission. This system would significantly reduce the mass necessary for rover motor control, making more mass space available to other important spacecraft systems. The current stage of the project consists of a desktop computer talking to a single "cold box" unit containing the electronics to drive a motor. In order to test the electronics, I developed a graphical user interface (GUI) using MATLAB to allow a user to send simple commands to the cold box and display the responses received in a user-friendly format.

  19. Final Report: MaRSPlus Sensor System Electrical Cable Management and Distributed Motor Control Computer Interface

    Science.gov (United States)

    Reil, Robin

    2011-01-01

    The success of JPL's Next Generation Imaging Spectrometer (NGIS) in Earth remote sensing has inspired a follow-on instrument project, the MaRSPlus Sensor System (MSS). One of JPL's responsibilities in the MSS project involves updating the documentation from the previous JPL airborne imagers to provide all the information necessary for an outside customer to operate the instrument independently. As part of this documentation update, I created detailed electrical cabling diagrams to provide JPL technicians with clear and concise build instructions and a database to track the status of cables from order to build to delivery. Simultaneously, a distributed motor control system is being developed for potential use on the proposed 2018 Mars rover mission. This system would significantly reduce the mass necessary for rover motor control, making more mass space available to other important spacecraft systems. The current stage of the project consists of a desktop computer talking to a single "cold box" unit containing the electronics to drive a motor. In order to test the electronics, I developed a graphical user interface (GUI) using MATLAB to allow a user to send simple commands to the cold box and display the responses received in a user-friendly format.

  20. Live-Grid Operation and Maintenance of the 35 kV/121 MVA Superconducting Cable System

    Institute of Scientific and Technical Information of China (English)

    Huan-Huan Li; An-Lin Ren; Ying Xin; Hui Hong; Zhi-Li Chen; Lin-Na Shi

    2008-01-01

    A 33.5 m, 35 kV/121 MVA, three-phase, warm dielectric HTS power cable system was successfully installed and activated in China Southern Power Grid at the Puji substation in Kunming on April 19th of 2004, supplying electricity to four industrial customers (including two metallurgical refineries) and a residential population of about 100000. In this paper, we give an update on the operation and maintenance status of the system and comments on reliability issues. We conclude that the superconducting cable system is currently quite robust and feasible for particular utility applications, and it will be improved by advancement in cryogenic equipment and system technology.

  1. Space Flight Cable Model Development

    Science.gov (United States)

    Spak, Kaitlin

    2013-01-01

    This work concentrates the modeling efforts presented in last year's VSGC conference paper, "Model Development for Cable-Harnessed Beams." The focus is narrowed to modeling of space-flight cables only, as a reliable damped cable model is not yet readily available and is necessary to continue modeling cable-harnessed space structures. New experimental data is presented, eliminating the low-frequency noise that plagued the first year's efforts. The distributed transfer function method is applied to a single section of space flight cable for Euler-Bernoulli and shear beams. The work presented here will be developed into a damped cable model that can be incorporated into an interconnected beam-cable system. The overall goal of this work is to accurately predict natural frequencies and modal damping ratios for cabled space structures.

  2. High Temperature Superconducting Underground Cable

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, Roger, A.

    2010-02-28

    The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

  3. Telemetry systems on cable tv networks (HFC); Sistema de telemetria sobre redes de TV a cabo (HFC)

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, Christina [Furukawa Industrial S.A. Produtos Eletricos, Curitiba, PR (Brazil). E-mail: christi@furukawa.com.br

    1999-07-01

    This paper presents a telemetry system on the cable TV (Hybrid Fiber Coaxial network). This system conducts remote electric power using the HFC network as physical way. The telemetry system represents an aggregated value on this type of network. The HFC network is a network prepared for data transport under the concept of a future wide single band network.

  4. Modern Fiber Optic Submarine Cable Telecommunication Systems Planning for Explosive Bandwidth Needs at Different Deployment Depths

    Directory of Open Access Journals (Sweden)

    Ahmed Nabih Zaki Rashed

    2012-10-01

    Full Text Available The explosive bandwidth needs, especially in the inter data center market, have pushed transmission data rates to 100 Gbit/sec and beyond. Current terrestrial fibers are inadequate for long haul, high bandwidth deployments. To solve these problems a new fiber is introduced for terrestrial high bandwidth deployments: different polymeric core fibers with enlarged effective area with a significant optical signal to noise ratio improvement over other conventional terrestrial single mode fibers. To ensure the new fiber may be deployed robustly a new coating structure was employed. A rigorous cable structure was then chosen for evaluation. Based on experimental data, both the deep ocean water temperature and pressure are tailored as functions of the water depth. As well as the product of the transmitted bit rate and the repeater spacing is processed over wide ranges of the affecting parameters. It is taken into account the estimation of the total cost of the submarine fiber cable system for transmission technique under considerations. The system capacity as well as the spectral losses, and the dispersion effects are parametrically investigated over wide range ranges of the set of affecting parameters {wavelength, ocean depth (and consequently the ocean pressure and temperature, and the chemical structure}.

  5. Modern Fiber Optic Submarine Cable Telecommunication Systems Planning for Explosive Bandwidth Needs at Different Deployment Depths

    Directory of Open Access Journals (Sweden)

    Ahmed Nabih Zaki Rashed

    2012-05-01

    Full Text Available The explosive bandwidth needs, especially in the inter data center market, have pushed transmission data rates to 100 Gbit/sec and beyond. Current terrestrial fibers are inadequate for long haul, high bandwidth deployments. To solve these problems a new fiber is introduced for terrestrial high bandwidth deployments: different polymeric core fibers with enlarged effective area with a significant optical signal to noise ratio improvement over other conventional terrestrial single mode fibers. To ensure the new fiber may be deployed robustly a new coating structure was employed. A rigorous cable structure was then chosen for evaluation. Based on experimental data, both the deep ocean water temperature and pressure are tailored as functions of the water depth. As well as the product of the transmitted bit rate and the repeater spacing is processed over wide ranges of the affecting parameters. It is taken into account the estimation of the total cost of the submarine fiber cable system for transmission technique under considerations. The system capacity as well as the spectral losses, and the dispersion effects are parametrically investigated over wide range ranges of the set of affecting parameters {wavelength, ocean depth (and consequently the ocean pressure and temperature, and the chemical structure}.

  6. Position-Controlled Data Acquisition Embedded System for Magnetic NDE of Bridge Stay Cables

    Directory of Open Access Journals (Sweden)

    Rouven Christen

    2010-12-01

    Full Text Available This work presents a custom-tailored sensing and data acquisition embedded system, designed to be integrated in a new magnetic NDE inspection device under development at Empa, a device intended for routine testing of large diameter bridge stay cables. The data acquisition (DAQ system fulfills the speed and resolution requirements of the application and is able to continuously capture and store up to 2 GB of data at a sampling rate of 27 kS/s, with 12-bit resolution. This paper describes the DAQ system in detail, including both hardware and software implementation, as well as the key design challenges nd the techniques employed to meet the specifications. Experimental results showing the performance of the system are also presented.

  7. Economical Aspects of Superconducting Cable

    Science.gov (United States)

    Ohya, Masayoshi

    High-temperature superconducting (HTS) cables are expected to resolve technical problems with power grids because they put large-capacity, low-loss power transmission into a compact package. One problem is replacing old 275-kV oil filled (OF) cables with cross-linked polyethylene insulated vinyl sheath cables (XLPE cables). This is difficult because XLPE cable has a lower transmission capacity than OF cable. In addition, the high concentration of public infrastructure underground makes it extremely difficult to build new ones. However, if 66-kV HTS cables can be installed inside existing underground conduits and can achieve a power capacity equivalent to conventional 275-kV cables, construction costs could be significantly reduced. Moreover, if XLPE cables are used for a 1,000 MVA-class transmission line, then three circuits of nine 275-kV single-core cables would be required, which would incur a transmission loss of 90 W/m/cct. Three circuits of three 66-kV Three-in-One HTS cables, however, with an AC loss of 1 W/m/ph@3 kA, heat invasion of 2 W/m, and cooling system efficiency of 0.1, would reduce transmission loss to less than three-fifths that of XLPE cables.

  8. 14 CFR 27.1365 - Electric cables.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would...

  9. Cable Television: Citizen Participation in Planning.

    Science.gov (United States)

    Yin, Robert K.

    The historical background of citizen participation in local affairs and its relevance at the onset of community concern about cable television are briefly discussed in this report. The participation of citizens, municipal officials, and cable operators in laying the groundwork for a cable system as well as the pros and cons of cable television as…

  10. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals.

    Science.gov (United States)

    Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf

    2017-08-01

    Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.

  11. Cable-truss supporting system for gob-side entry driving in deep mine and its application

    Institute of Scientific and Technical Information of China (English)

    Yin Qian; Jing Hongwen; Dai Dapeng; Zhu Tantan; Zhao Honghui; Meng Bo

    2016-01-01

    In order to solve the large deformation controlling problem for surrounding rock of gob-side entry driving under common cable anchor support in deep mine, site survey, physical modeling experiment, numerical simulation and field measurement were synthetically used to analyze the deformation and failure char-acteristics of surrounding rock. Besides, applicability analysis, prestress field distribution characteristics of surrounding rock and the control effect on large deformation of surrounding rock were also further studied for the gob-side entry driving in deep mine using the cable-truss supporting system. The results show that, first, compared with no support and traditional bolt anchor support, roof cable-truss system can effectively restrain the initiation and propagation of tensile cracks in the roof surrounding rock and arc shear cracks in the two sides, moreover, the broken development of surrounding rock, roof separation and extrusion deformation between the two sides of the roadway are all controlled;second, a prestressed belt of trapezoidal shape is generated in the surrounding rock by the cable-truss supporting system, and the prestress field range is wide. Especially, the prestress concentration belt in the shallow surrounding rock can greatly improve the anchoring strength and deformation resisting capability of the rock stratum;third, an optimized support system of‘roof and side anchor net beam, roof cable-truss supporting system and anchor cable of the narrow coal pillar” was put forward, and the support optimization design and field industrial test were conducted for the gob-side entry driving of the working face 5302 in Tangkou Mine, from which a good supporting effect was obtained.

  12. Identification of problems when using long high voltage AC cable in transmission system II: Resonance & Harmonic resonance

    DEFF Research Database (Denmark)

    Rahimi, Saeed; Wiechowski, W.; Randrup, M.;

    2008-01-01

    cable in transmission system. The objective of this paper and the companion paper is to address the most important problems expected in transmission system with relatively larger share of long HV underground cables. The end goal will be a guideline to special solutions and precautions to avoid dangerous...... over voltage problems and also resonance problems in a transmission network with future increased share of cables. Two major categories of problems are switching transient and resonance problems. In each category of the possible problems, first some theoretical background is provided...... and then the problem and countermeasures are discussed. In this paper most important resonance problems are addressed and discussed. Three main categories of resonance problems are: Near Resonance, Harmonic resonance and Ferroresonance....

  13. Open Location Management in Automated Warehousing Systems

    NARCIS (Netherlands)

    Y. Yu (Yugang); M.B.M. de Koster (René)

    2009-01-01

    textabstractA warehouse needs to have sufficient open locations to be able to store incoming shipments of various sizes. In combination with ongoing load retrievals open locations gradually spread over the storage area. Unfavorable positions of open locations negatively impact the average load retri

  14. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Directory of Open Access Journals (Sweden)

    Tongzhi Zhang

    2016-11-01

    Full Text Available We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  15. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System.

    Science.gov (United States)

    Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun

    2016-11-30

    We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa ) . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  16. Parametric Vibration and Vibration Reduction of Cables in Cable-stayed Space Latticed Structure

    Institute of Scientific and Technical Information of China (English)

    BAO Yan; ZHOU Dai; LIU Jie

    2008-01-01

    Mechanical model and vibration equation of a cable in cable-stayed sparse latticed structure (CSLS) under external axial excitation were founded. Determination of the mass lumps and natural frequencies supplied by the space latticed structure (SLS) was analyzed. Multiple scales method (MSM) was introduced to analyze the characteristics of cable's parametric vibration, and the precise time-integration method (PTIM) was used to solve vibration equation. The vibration behavior of a cable is closely relative to the frequency ratio of the cable and SLS. The cable's parametric vibration caused by the external axial excitation easily occurs if the frequency ratio of the cable and SLS is in a certain range, and the cable's vibration amplitude varies greatly even if the initial disturbance supplied by SLS changes a little. Furthermore, the mechanical model and vibration equation of the composite cable system consisting of main cables and assistant cables were studied. The parametric analysis such as the pre-tension level and arrangement of the assistant cables was carried out. Due to the assistant cables, the single-cable vibration mode can be transferred to the global vibration mode, and the stiffness and damping of the cable system are enhanced. The natural frequencies of the composite cable system with the curve line arrangement of assistant cables are higher than those with the straight-line arrangement and the former is more effective than the latter on the cable's vibration suppression.

  17. Full-Scale Measurements and System Identification on Sutong Cable-Stayed Bridge during Typhoon Fung-Wong

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2014-01-01

    Full Text Available The structural health monitoring system (SHMS provides an effective tool to conduct full-scale measurements on existing bridges for essential research on bridge wind engineering. In July 2008, Typhoon Fung-Wong lashed China and hit Sutong cable-stayed bridge (SCB in China. During typhoon period, full-scale measurements were conducted to record the wind data and the structural vibration responses were collected by the SHMS installed on SCB. Based on the statistical method and the spectral analysis technique, the measured data are analyzed to obtain the typical parameters and characteristics. Furthermore, this paper analyzed the measured structural vibration responses and indicated the vibration characteristics of the stay cable and the deck, the relationship between structural vibrations and wind speed, the comparison of upstream and downstream cable vibrations, the effectiveness of cable dampers, and so forth. Considering the significance of damping ratio in vibration mitigation, the modal damping ratios of the SCB are identified based on the Hilbert-Huang transform (HHT combined with the random decrement technique (RDT. The analysis results can be used to validate the current dynamic characteristic analysis methods, buffeting calculation methods, and wind tunnel test results of the long-span cable-stayed bridges.

  18. Full-scale measurements and system identification on Sutong cable-stayed bridge during Typhoon Fung-Wong.

    Science.gov (United States)

    Wang, Hao; Tao, Tianyou; Guo, Tong; Li, Jian; Li, Aiqun

    2014-01-01

    The structural health monitoring system (SHMS) provides an effective tool to conduct full-scale measurements on existing bridges for essential research on bridge wind engineering. In July 2008, Typhoon Fung-Wong lashed China and hit Sutong cable-stayed bridge (SCB) in China. During typhoon period, full-scale measurements were conducted to record the wind data and the structural vibration responses were collected by the SHMS installed on SCB. Based on the statistical method and the spectral analysis technique, the measured data are analyzed to obtain the typical parameters and characteristics. Furthermore, this paper analyzed the measured structural vibration responses and indicated the vibration characteristics of the stay cable and the deck, the relationship between structural vibrations and wind speed, the comparison of upstream and downstream cable vibrations, the effectiveness of cable dampers, and so forth. Considering the significance of damping ratio in vibration mitigation, the modal damping ratios of the SCB are identified based on the Hilbert-Huang transform (HHT) combined with the random decrement technique (RDT). The analysis results can be used to validate the current dynamic characteristic analysis methods, buffeting calculation methods, and wind tunnel test results of the long-span cable-stayed bridges.

  19. Design, Observing and Data Systems, and Final Installation of the NEPTUNE Canada Regional Cabled Ocean Observatory

    Science.gov (United States)

    Barnes, C. R.; Best, M. M.; Johnson, F. R.; Phibbs, P.; Pirenne, B.

    2009-05-01

    /climate dynamics, including acidification and nutrient fluxes; deep-sea ecosystems dynamics; and engineering and computer science research. NC's software system interfaces between users and cabled observatory and responds to a three-fold mandate: acquire data from various instruments/sensors underwater; provide lifetime storage and redistribution capabilities for all data; and allow authorized users to remotely and interactively control experiments. Data Management and Archiving System (DMAS) is being developed in-house, with adoption of Service-Oriented Architecture (SOA) and using Web Services to expose the functionality of DMAS' various components. An internal messaging bus allows various functional components to interact through the publish and subscribe paradigm, using Java programming language. DMAS is developing a modern environment for users: data access, data processing and experimentation control within a Web 2.0 environment. This will allow users, on top of data and instrumentation access, to perform data visualization and analysis on-line with either default or custom processing code, as well as simultaneously interacting with each other. These social networking aspects will be within NC's new Oceans 2.0 environment. The observatory is designed to be expandable in its footprint, nodes and instruments and provides a magnificent facility for testing prototypes of new technologies monitored and demonstrated in real-time. NC and ONC invite new scientific and industrial participation, experiments, instrumentation and data services.

  20. Modelling of long High Voltage AC Cables in the Transmission System

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella

    , EMTDC/PSCAD is provided. A typical HV AC underground power cable is formed by 4 main layers, namely; Conductor-Insulation-Screen-Insulation. In addition to these main layers, the cable also has semiconductive screens, swelling tapes and metal foil. For high frequency modelling in EMT-based software...... and field measurement results. This is because of intersheath mode reflecting from the crossbonding points. The second main part of the work deals with improving the cable model based on the findings from analysis of the field measurements. The existing EMT-based models have the configuration for cables...

  1. Facilitating location independence with computerized conversation systems

    OpenAIRE

    E J Menasse Noble; J.; Adler

    1996-01-01

    Location independence for organizations is desirable if they wish to achieve a given spatial distribution in a regional development plan. An organization's interaction with its environment forms the basis of its daily work and takes the form of 'information links' composed of fundamental indivisible blocks called 'conversations'. To achieve location independence it is necessary for organizations to develop and maintain environment interactions independent of their location. Information techno...

  2. Cryogenic design of liquid-nitrogen circulation system for long-length HTS cables with altitude variation

    Science.gov (United States)

    Chang, Ho-Myung; Ryu, Ki Nam; Yang, Hyung Suk

    2017-04-01

    Liquid-nitrogen (LN2) circulation systems with altitude variation are investigated and designed for application to practical long-length HTS cables. This study is motivated by the KEPCO's immediate plan to install new HTS cables in existing utility tunnels including inclined and vertical sections. The distribution of pressure and temperature along the LN2 circulation loop is examined for various geographic conditions, taking into account the gravitational effect of altitude variation. The cryogenic cooling requirements are defined in terms of the pressure and temperature of LN2, and a design process is graphically demonstrated on phase diagram. It is concluded that the LN2 flow rate along the cable with altitude variation should be carefully determined with the constraints on pressure and temperature, and the proposed graphical method is useful in the design.

  3. the automatic lightening location system and its implications for the ...

    African Journals Online (AJOL)

    ES Obe

    systems. The implications of the lightening location system for the Nigerian electric power system are also highlighted ... to be protected from the ground flash. ... measuring the lightening flash density ..... lightning location equipment in Norway,.

  4. New Compact Ocean Bottom Cabled Seismic and Tsunami Observation System Using ICT

    Science.gov (United States)

    Shinohara, M.; Yamada, T.; Sakai, S.; Shiobara, H.; Kanazawa, T.

    2013-12-01

    The Pacific plate is subducting below the northeastern Japan islands arc. The 2011 Tohoku earthquake occurred at the plate boundary between the Pacific plate and the landward plate below landward slope of the Japan Trench. In 1996, Earthquake Research Institute (ERI), University of Tokyo had installed seismic and tsunami observation system using seafloor optical fiber in the off-Sanriku area. The continuous real-time observation has been carried out since the installation. The system observed seismic waves and tsunamis generated by the 2011 Tohoku earthquake, and the data from the system are indispensable to estimate accurate position of the source faults and the source process of the 2011 event. However, the landing station of the system was damaged by huge tsunami 30 minutes after the mainshock, and the observation is discontinued. Because the data from the real-time system on seafloor are important, we decide to restore the existing system and install newly developed Ocean Bottom Cabled Seismic and Tsunami (OBCST) observation system off Sanriku for additional observation and/or replacement of the existing system. In this paper, we present a system of the new OBCST in detail, and installation plan. Until 2010, we had already developed and installed the new compact Ocean Bottom Cabled Seismometer (OBCS) system near Awashima-island in the Japan Sea. After the installation, the OBCS system is being operated continuously and we have continuous seismic data for approximately 3 years at the present. The new OBCST system for off-Sanriku area is based on this system, and is characterized by system reliability using TCP/IP technology and down-sizing of an observation node using up-to-date electronics. The new OBCST has three accelerometers as seismic sensors. Signals from accelerometers are 24-bit digitized with a sampling rate of 1 kHz and sent to a landing station using standard TCP/IP data transmission. A precise pressure gauge is also equipped as a tsunami sensor. The

  5. 同向回转拉索锚固体系斜拉索施工技术%Construction Techniques for Stay Cables Provided with Isodirectionally Turning Stay Cable Anchor System

    Institute of Scientific and Technical Information of China (English)

    李景丰; 周伟明

    2015-01-01

    安徽五河定淮淮河特大桥主桥为独塔双索面混合梁斜拉桥,跨径布置为246 m+125 m,该桥采用钢绞线斜拉索,斜拉索采用同向回转拉索锚固体系,即斜拉索穿过桥面一侧锚具,绕过桥塔后锚回到桥面另一侧锚具,形成同一对编号斜拉索。同向回转拉索锚固体系由钢绞线拉索系统、夹持型大转角鞍座锚索系统及主梁锚拉板锚索系统3部分组成。斜拉索采用三角提升原理安装,利用穿索机推送及卷扬机牵引将主梁一侧的钢绞线送入HDPE外套管中,穿过鞍座后,通过穿索机推送及另外一台卷扬机牵引钢绞线回到主梁另一侧锚固区,钢绞线穿索就位后,采用单股对称张拉法进行斜拉索张拉,张拉到位后进行封锚处理。%The main bridge of Dinghuai Huaihe River Bridge in Wuhe ,Anhui is a hybrid girder cable‐stayed bridge with a single pylon ,double cable planes and with span arrangement 246 m+125 m .The stay cables of the bridge are the steel wire strand cables and are anchored by the isodi‐rectionally turning stay cable anchor system .That is ,a full long stay cable of the bridge is firstly extended out of its anchor at one side of the bridge deck and is led to the saddle in the pylon ,then the cable transversely turns around at the saddle and is finally led downwards and extended into the anchor at the other side of the deck to consequently form a pair of the cables of the same numbe‐ring .The isodirectionally turning stay cable anchor system is comprised of 3 parts of the stay cable system ,large turning angle clamping saddle anchor in the pylon and the anchor tensile plate anchor in the main girder .The stay cables of the bridge are installed ,using the principle of the triangle‐shape lifting .By the delivering of the cable threading machine and the hauling of the winch ,the steel wire strands of a cable on one side of the deck are led into the HDPE sheaths and the sheathed

  6. Line Differential Protection Scheme Modelling for Underground 420 kV Cable Systems, EMTDC/PSCAD Relays Modelling

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sztykiel, Michal; Dollerup, Sebastian

    2011-01-01

    Based on the analysis of a specific relay model and an HVAC (High Voltage Alternating Current) cable system, a new approach to EMTDC/PSCAD modelling of protective relays is presented. Such approach allows creating complex and accurate relay models derived from the original algorithms. Relay model...

  7. Design of a cryogenic system for a 20m direct current superconducting MgB2 and YBCO power cable

    Science.gov (United States)

    Cheadle, Michael J.; Bromberg, Leslie; Jiang, Xiaohua; Glowacki, Bartek; Zeng, Rong; Minervini, Joseph; Brisson, John

    2014-01-01

    The Massachusetts Institute of Technology, the University of Cambridge in the United Kingdom, and Tsinghua University in Beijing, China, are collaborating to design, construct, and test a 20 m, direct current, superconducting MgB2 and YBCO power cable. The cable will be installed in the State Key Laboratory of Power Systems at Tsinghua University in Beijing beginning in 2013. In a previous paper [1], the cryogenic system was briefly discussed, focusing on the cryogenic issues for the superconducting cable. The current paper provides a detailed discussion of the design, construction, and assembly of the cryogenic system and its components. The two-stage system operates at nominally 80 K and 20 K with the primary cryogen being helium gas. The secondary cryogen, liquid nitrogen, is used to cool the warm stage of binary current leads. The helium gas provides cooling to both warm and cold stages of the rigid cryostat housing the MgB2 and YBCO conductors, as well as the terminations of the superconductors at the end of the current leads. A single cryofan drives the helium gas in both stages, which are thermally isolated with a high effectiveness recuperator. Refrigeration for the helium circuit is provided by a Sumitomo RDK415 cryocooler. This paper focuses on the design, construction, and assembly of the cryostat, the recuperator, and the current leads with associated superconducting cable terminations.

  8. Design and Tests of A Cable Detection Laser Imaging Radar System

    Institute of Scientific and Technical Information of China (English)

    WANG Wei-ran; YUAN Jin

    2005-01-01

    Rotorcraft in low-level flight is endangered by power lines or telephone wires. The development of automation tools that can detect obstacles in the flight path and warn the crew would significantly reduce pilot workload and increase safety. Therefore, a cable detection radar system is developed. The real-time dynamic imaging synchronizing with radar space scanning has been implemented in developed ladar system. The requirements of the flight mission to prevent "wire strike"are analyzed and estimated, the advantages and disadvantages of the millimeter wave system with the laser system are weighted. The result shows that Laser system is the best suited for helicopter avoidance obstacle. In addition, several design gist of detecting wire radar that was used in the developed ladar system is proposed and the developed zero backlash imaging technology and several advanced warning function are described. The detailed results of system ground tests and the performances description are presented. The ground test of the developed ladar system has demonstrated that the developed imaging ladar system performance can achieve and satisfy the requirements of the mission to prevent "wire strike".

  9. Derivation of Theoretical Formulas of Sequence Currents on Underground Cable System

    DEFF Research Database (Denmark)

    Ohno, Teruo; Ametani, Akihiro; Bak, Claus Leth

    the installation and it is difficult to predict these values beforehand with good accuracy. This paper derives theoretical formulas of the sequence currents for a cross-bonded cable and a normal-bonded cable. The accuracy of the proposed formulas is verified through a comparison with EMTP simulations....

  10. Location - Global Positioning System (GPS) Photos

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — Digital photos tagged with GPS location information. The St. Paul District maintains a digital library of over 10,000 GPS photos. Photos are often associated with...

  11. Semiannual report for the period October 1, 1978 to March 31, 1979 of work on: (1) superconducting power transmission system development; and (2) cable insulation development

    Energy Technology Data Exchange (ETDEWEB)

    1979-05-11

    The objective of the program is to develop an underground superconducting power transmission system which is economical and technically attractive to the utility industry. The system would be capable of carrying very large blocks of electric power, thus enabling it to supplant overhead lines in urban and suburban areas and regions of natural beauty. The program consisted initially of work in the laboratory to develop suitable materials, cryostats, and cable concepts. The materials work covers the development and testing of suitable superconductors, and dielectric insulation. The laboratory work has now been extended to an outside test facility which represents an intermediate step between the laboratory scale and a full-scale system. The facility will allow cables several hundred feet long to be tested under realistic conditions. In addition, the refrigerator has been designed for optimum service for utility applications. Progress in cable conductor and cable insulation development and in the engineering facilities for fabricating and testing the superconducting cables is reported. (LCL)

  12. Multipurpose locator tag system : LDRD 65145 final report.

    Energy Technology Data Exchange (ETDEWEB)

    Greenway, Douglas Jr.; Schuster, Gary R.

    2003-11-01

    This report summarizes work performed to determine the capability of the Pinpoint Locator system, a commercial system designed and manufactured by RF Technologies. It is intended for use in finding people with locator badges in multi-story buildings. The Pinpoint system evaluated is a cell-based system, meaning it can only locate badges within an area bordered by its antennas.

  13. Composite active control system of roof and side truss cable for large section coal roadway in fold coal pillar area

    Institute of Scientific and Technical Information of China (English)

    Sheng-Rong XIE; Er-Peng LI; Fu-Lian HE; Shou-Bao ZHANG; Guang-Chao ZHANG; Mao-Yu PANG

    2013-01-01

    In order to solve the surrounding rock control problem of large section gangue replacement roadway under complicated conditions,this paper analyzed the impact to the roadway controlling produced by the geological conditions such as high ground stress,folded structure tilted roof asymmetry and soft wall rock,and built the tilt layered roof structural mechanics model to clarify the increase span mechanism of the weak coal instability.Then,we proposed the combined control system including roof inclined truss cable,coal-side cable-channel steel and intensive bolt support.And then by building the structural mechanics model of roof inclined truss cable system,the support principle was described.Besides,according to this model,we deduced the calculation formula of cable anchoring force and its tensile stress.Finally surrounding rock control technology of large section roadway in fold coal pillar area was formed.Field practice shows that the greatest roof convergence of gangue replacement roadway is 158 mm and coal-side deformation is 243 mm.Roadway deformation is controlled effectively and technical support is provided for replacement mining.

  14. Robotic Arm Biobarrier Cable

    Science.gov (United States)

    2008-01-01

    This image, taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander on the 14th Martian day of the mission (June 7, 2008), shows the cable that held the Robotic Arm's biobarrier in place during flight has snapped. The cable's springs retracted to release the biobarrier right after landing. To the lower right of the image a spring is visible. Extending from that spring is a length of cable that snapped during the biobarrier's release. A second spring separated from the cable when it snapped and has been photographed on the ground under the lander near one of the legs. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. Robotic Arm Biobarrier Cable

    Science.gov (United States)

    2008-01-01

    This image, taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander on the 14th Martian day of the mission (June 7, 2008), shows the cable that held the Robotic Arm's biobarrier in place during flight has snapped. The cable's springs retracted to release the biobarrier right after landing. To the lower right of the image a spring is visible. Extending from that spring is a length of cable that snapped during the biobarrier's release. A second spring separated from the cable when it snapped and has been photographed on the ground under the lander near one of the legs. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  16. Cable tensiometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, B.V

    1989-05-30

    This patent describes a weight beam for measuring load on a cable. The weight beam consists of: a beam body; load cell means mounted on the beam body, the load cell means being spaced a predetermined distance from the beam body; clamp means connected to the load cell means and adapted to grip a cable whose tension is to be measured; and adjusting means connected to the load cell to deflect the cable and put the load cell under a tension load, the clamp means and the adjusting means being structurally distinct.

  17. Design of an All-dielectric Self-supporting Cable System

    Institute of Scientific and Technical Information of China (English)

    George G. Karady; Kumaraguru Prabakar

    2011-01-01

    All-dielectric self-supporting (ADSS) cables are installed along with transmission line for the purpose of communication. During installation the outer layer of the cable is hydrophobic and is not prone to dry band arcing. These cables become less hydrophobic over time and become vulnerable to dry band arcing. This loss in hydrophobici- ty is because of the contamination formed on the outer layer due to pollution. This is one of the reasons which cause cable failure. Considerable amount of losses will be incurred on the occurrence of a cable failure as the cables are also leased to other companies. An improved equivalent circuit is used to calculate the voltage and current distribution of the double circuit line. A three-phase single circuit line and a three-phase double circuit line are used to calculate their corresponding voltage distribution and current distribution. The results could be used to predict dry band arcing on similar models. The method used considers sag, span and pollution on ADSS cable.

  18. Research for the Cable Layout Way of the Bypass Operation System in Agricultural Power Supply Network

    Science.gov (United States)

    Niu, Jie; Li, Jinliang; Zou, Dehua; Yang, Qi; Li, Xu; Yan, Yu; Li, Tang

    2017-05-01

    Non-blackout working of agricultural power supply network is significant to shorten the outage time, decrease the outage loss, and improve the supply reliability and safety. It is impossible to hang the wire rope first and then suspend the cable because of the poor bearing ability of the pole in agricultural power supply network. A kind of new cable arrangement way, its matching tools and the flexible cable that can bear the tension by itself are needed to be put forward and developed. It is necessary to calculate the electric field intensity of the flexible cable to verify that the electric field intensity meets the insulation demand. In this new design, the fiber layer is added into the flexible cable and its maximum tension force is measured to reach to 4000 N. Based on the features of live working in the agricultural power supply network, the new layout way of the cable is proposed; the matching tools and the new flexible cable that can bear the tension by itself are developed as well in this paper. All of the research achievements can give references for the live working of the agricultural power supply network.

  19. AC Cable: Yokohama Project

    Science.gov (United States)

    Masuda, Takato

    High Temperature Superconducting (HTS) cables can transmit large amounts of electricity in a compact size with minimal losses. Therefore, they are expected to save the construction cost of underground lines in urban areas and decrease transmission losses. Several HTS cables have recently been demonstrated in networks around the world, and full-scale commercialization is expected in the near future. In Japan, the development of compact HTS cables suitable for urban deployment has been underway since the early 1990s. In 2007, a national project was started to verify their operational performance and long-term reliability in the grid. An HTS cable 240 m long was installed at the Asahi substation of the Tokyo Electric Power Company (TEPCO) in Yokohama; then a joint, terminations and cooling system was constructed in 2011. After successful performance tests, the cable was connected to the grid for the first time in Japan, and started to deliver electricity to 70,000 households in October 2012. This trouble-free in-grid service continued for over a year. We can conclude that the HTS cable system performs well and has the stability required for long-term in-grid operations.

  20. The design and fabrication of a reverse Brayton cycle cryocooler system for the high temperature superconductivity cable cooling

    Science.gov (United States)

    Park, Jae Hong; Kwon, Yong Ha; Kim, Young Soo

    2005-01-01

    A high temperature superconductivity cable must be cooled below the nitrogen liquefaction temperature to apply the cable to power generation and transmission systems under superconducting state. To maintain the superconducting state, a reliable cryocooler system is also required. The design and fabrication of a cryocooler system have been performed with a reverse Brayton cycle using neon gas as a refrigerant. The system consists of a compressor, a recuperator, a cold-box, and control valves. The design of the system is made to have 1 kW cooling capacity. The heat loss through multilayer insulators is calculated. Conduction heat loss is about 7 W through valves and access ports and radiation heat loss is about 18 W on the surface of a cryocooler. The design factors are discussed in detail.

  1. Superconductor cable

    Science.gov (United States)

    Allais, Arnaud; Schmidt, Frank (Langenhagen, DE

    2009-12-15

    A superconductor cable includes a superconductive cable core (1) and a cryostat (2) enclosing the same. The cable core (1) has a superconductive conductor (3), an insulation (4) surrounding the same and a shielding (5) surrounding the insulation (4). A layer (3b) of a dielectric or semiconducting material is applied to a central element (3a) formed from a normally conducting material as a strand or tube and a layer (3c) of at least one wire or strip of superconductive material is placed helically on top. The central element (3a) and the layer (3c) are connected to each other in an electrically conducting manner at the ends of the cable core (1).

  2. Cable networks, services, and management

    CERN Document Server

    2015-01-01

    Cable Networks, Services, and Management is the first book to cover cable networks, services, and their management, in-depth, for network operators, engineers, researchers, and students. Thirteen experts in various fields have contributed their knowledge of network architectures and services, Operations, Administration, Maintenance, Provisioning, Troubleshooting (OAMPT) for residential and business services, cloud, Software Defined Networks (SDN), as well as virtualization concepts and their applications as part of the future directions of cable networks. The book begins by introducing architecture and services for Data Over Cable Service Interface Specification (DOCSIS) 3.0/ 3.1, Converged Cable Access Platform (CCAP), Content Distribution Networks (CDN, IP TV, and Packet Cable and Wi-Fi for Residential Services. Topics that are discussed in proceeding chapters include: operational systems and management architectures, service orders, provisioning, fault manageme t, performance management, billing systems a...

  3. The Lighthouse Ocean Research Initiative: Sustained Cabled Ocean Observing Systems in the Sea of Oman and Arabian Sea

    Science.gov (United States)

    Ingle, S.; Du Vall, K.; Dimarco, S. F.

    2011-12-01

    In 2003 Lighthouse R & D Enterprises, Inc. began developing an ocean observing system that would help the Sultanate of Oman better manage the health of their fisheries. The resulting cutting-edge, fiber-optic cabled ocean observatory was installed in the northern Sea of Oman and became operational in August of 2005; this summer the system surpassed the milestone of 2100 days of successful operation. A second, deepwater cabled observatory was installed farther to the south, where the Sea of Oman meets the Arabian Sea, in January, 2010. Both systems monitor physical properties throughout the water column including current velocity, temperature, pressure, conductivity, dissolved oxygen and turbidity. The entirely subsea nature of the fiber-optic cabled observatory capitalizes on several advantages over traditional buoyed systems including a lack of exposure to environmental wear and tear, collision, vandalism and theft. The systems are both cabled to nearby shore facilities, where the data are relayed instantly to Houston via satellite for processing, analysis and modeling - the data may also be used in making real time decisions. Many challenges were encountered between the design / development stage and the operation a reliable, long-term, real-time observing system in a dynamic marine environment. Examples of obstacles we encountered and overcame include: maintaining upright mooring strings under differential current velocities; minimizing points of weakness in the system, especially the number of wet mates; recognizing the need for cathodic protection in unanticipated places; protecting vulnerable sensors from biofouling; developing a climate-controlled shore facility in a harsh and remote environment; ensuring an uninterrupted power supply and availability of additional power bursts when required; and lengthening the life of the system while reducing the need for maintenance. The design and obstacles and scientific questions being addressed by the Lighthouse

  4. Dynamic testing of cable structures

    Directory of Open Access Journals (Sweden)

    Caetano Elsa

    2015-01-01

    Full Text Available The paper discusses the role of dynamic testing in the study of cable structures. In this context, the identification of cable force based on vibration measurements is discussed. Vibration and damping assessment are then introduced as the focus of dynamic monitoring systems, and particular aspects of the structural behaviour under environmental loads are analysed. Diverse application results are presented to support the discussion centred on cable-stayed bridges, roof structures, a guyed mast and a transmission line.

  5. Research and Application of Multiaxial-cable Parallel Control System%多轴柔索并联控制系统的分析与应用

    Institute of Scientific and Technical Information of China (English)

    刘建国; 何雨彤

    2016-01-01

    分析舞台新型运动控制系统——柔索驱动系统的单轴柔索独立控制和多轴柔索并联控制两方面的系统设计及其应用。%In this paper , the author analysised the system design and application of uniaxial-cable independence control and multiaxial-cable parallel control in the cable-driven system which was new stage motion control system.

  6. 76 FR 66666 - Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics Equipment

    Science.gov (United States)

    2011-10-27

    ... Electronics Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule. SUMMARY: In this... consumer electronics equipment for most subscribers. At the same time, however, we recognize that some... Act), Congress recognized that compatibility problems between cable service and consumer...

  7. Tensile force identification in cable-stayed structures: Hybrid system identification algorithm and experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Myung Hyun [POSCO, Incheon (Korea, Republic of); Hu, Jong Wan [Incheon National University, Incheon (Korea, Republic of)

    2014-11-15

    In this study, we investigate a method to detect tensile forces in cable-stayed structures using the combined sensitivity updating method and the advanced hybrid microgenetic algorithm. The proposed method allows us not only to avoid the trap of minimum at initial searching stage but also to find their final solutions in better numerical efficiency. The validity of the technique is numerically verified using a set of dynamic data obtained from a simulation of the cable model modeled using the finite element method. Then, the hybrid algorithm is applied to vibrating sagged cables in the laboratory scale test. The results obtained are in good agreement with the semi-analytical solutions and experimental results reported by other investigators. The results indicate that the new method is computationally efficient in characterizing the tensile force variation for cable-stayed structures.

  8. Lightweight Metal Rubber Wire and Cable for Space Power Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this NASA STTR program is to produce ultra-lightweight electrical wire and cable harnesses to reduce the liftoff weight of future space flight...

  9. The power supply system model of the process submersible device with AC power transmission over the cable-rope

    Science.gov (United States)

    Rulevskiy, V. M.; Bukreev, V. G.; Kuleshova, E. O.; Shandarova, E. B.; Shandarov, S. M.; Vasilyeva, Yu Z.

    2017-02-01

    A practical problem of power supply system modeling for the process submersible device with AC power transmission over the cable-rope was considered. The problem is highly relevant in developing and operation of submersible centrifugal pumps and submersibles. The results of modeling a symmetrical three-phase power supply system and their compliance with the real data are given at the paper. The obtained results in the mathematical and simulation models were similar.

  10. A project plan for construction and cabling of picture archiving and communication system network

    Institute of Scientific and Technical Information of China (English)

    罗敏; 王小林; 罗松; 雷文勇; 王学健; 温洪宇; 吴红星

    2003-01-01

    Objective To determine a network solution to meet the network requirements of the heavy data flow, load balance, and potential network storms from expansion of picture archiving and communication system (PACS) application.Methods Intel Netstructure 480T Giga Switch was used as the main switch and connected to each building by fiber channel at 1 Giga speed to archive 100 MB/s to each port. At the same time, the in-dependence of the original network construction was physically kept. The layer 3 and 4 switchers were used as load balance to reduce the heavy load of the network, and all the cabling for PACS used the super CAT5 along with the Intel NetStructure 1520 to prepare for potential network storms.Results An advanced intranet was set up to fully meet the high standard requirement of the PACS. The foundation for upgrading the whole network system to 1 Giga application was built to achieve sharing and transmission of images, information, and patient data within the hospital. The base was established for the standardized management of the hospital.Conclusion Good planning is the first step in setting up PACS, and the equipment from the necessary platform to run PACS and all kinds of hospital information system (HIS). The networking construction is the foundation of e-hospital.

  11. 47 CFR 32.2426 - Intrabuilding network cable.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Intrabuilding network cable. 32.2426 Section 32... Intrabuilding network cable. (a) This account shall include the original cost of cables and wires located on the... between buildings on one customer's same premises. Intrabuilding network cables are used to...

  12. 46 CFR 58.60-5 - Industrial systems: Locations.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Industrial systems: Locations. 58.60-5 Section 58.60-5... MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-5 Industrial systems: Locations. An industrial system under this subpart must not be in a...

  13. Impact of cross-tie design on the in-plane stiffness and local mode formation of cable networks on cable-stayed bridges

    Science.gov (United States)

    Ahmad, Javaid; Cheng, Shaohong; Ghrib, Faouzi

    2016-02-01

    Suppressing unfavorable stay cable vibrations using cross-ties is becoming more popular on cable-stayed bridges though the mechanics of the formed cable network is yet fully understood. In practice, the main task in designing cross-ties or cable networks is to choose the cross-tie installation location, stiffness and number based on the main cable properties in the network. To have a more comprehensive picture of how to choose these design parameters to achieve higher in-plane network stiffness while minimizing the number of excited local modes, it is imperative to examine dynamic behavior of cable networks with general configurations. In the current study, an analytical model of a general cable network consisting of multiple main cables interconnected by multiple lines of transverse flexible cross-ties will be developed. A new term, defined as the local mode cluster, will be introduced to assess the severity of local mode excitation. Criteria for identifying the presence of local mode cluster will be proposed. A parametric study will be conducted to evaluate the impact of cross-tie installation location, stiffness and number on the network modal response. Results obtained from the present study will provide deeper insight into the selection of these system parameters to achieve the combined benefits of increasing network in-plane stiffness and minimizing the excitation of local modes.

  14. Field validation of cable monitoring and rating system (CMARS) laboratory model. Semi-annual report, 1 May 1979-31 December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Englehardt, J.; Harris, H.; Kasny, E.; Orifice, D.; Patton, R.; Sottovia, P.

    1980-01-01

    One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)

  15. A cable position sorting method for the balance of current distribution of parallel connected cables

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.Y. [Northern Taiwan Inst. of Science and Technology, Taipei, Taiwan (China); Yu, C.S. [National Defence Univ., Taoyuan, Taiwan (China); Wang, S.C. [Lung Hwa Univ. of Science and Technology, Taoyuan, Taiwan (China); Chen, Y.L. [MingChi Univ. of Technology, Taipei, Taiwan (China)

    2006-07-01

    In order to meet the high ampacity requirement of a low voltage main feeder, single-core power cables are usually connected in parallel in Taiwan's industrial and commercial power distribution systems. However, parallel connected cables can be problematic due to unequal current distributions among cables of the same phase, causing excessive temperature rise in the heavier loading cables, thus reducing the life expectancy of cable insulation. One of the most effective and economical methods of balancing current distributions is a properly designed cable position arrangement. This paper proposed a cable position sorting method for the balance of current distribution of parallel connected cables. A current distribution calculation method was developed based on mutual inductance theorem and the numerical iteration technique. In order to implement the sorting algorithm, two current distribution indices were proposed for the power loss of all cables and for the largest cable current value. The index values of different cable arrangement patterns generated by a novel permutation reduction method were determined and sorted and 3 cable configurations were studied. Recommendations for the arrangement of cable positions, aiming for more balanced current distributions, were also presented. It was concluded that dividing the cables into subgroups, including only one cable per phase in a subgroup, and arranging the cables in symmetric form can achieve a very balanced current distribution. 5 refs., 14 tabs., 7 figs.

  16. STATIC ANALYSIS OF CABLE STRUCTURE

    Institute of Scientific and Technical Information of China (English)

    HUANG Yan; LAN Wei-ren

    2006-01-01

    Based on the nonlinear geometric relation between strain and displacement for flexible cable, the equilibrium equation under self-weight and influence of temperature was established and an analytical solution of displacement and tension distribution defined in Eulerian coordinate system was accurately obtained. The nonlinear algebraic equations caused by cable structure were solved directly using the modified Powell hybrid algorithm with high precision routine DNEQNE of Fortran. For example, a cable structure consisting of three cables jointly supported by a vertical spring and all the other ends fixed was calculated and compared with various methods by other scholars.

  17. Localization of troubles in telephone cable networks

    Energy Technology Data Exchange (ETDEWEB)

    Chuxin Chen; Hollidge, T.L.; Sharma, D.D. [Pacific Bell, San Ramon, CA (United States)

    1996-12-31

    This paper describes an intelligent system which detects the location of troubles in a local telephone cable network. Such a task is very challenging, tedious, and requires human experts with years of experience and high analytical skills. Our system captures the expertise and knowledge required for this task, along with automated access to database systems, so that the system can help a human analyst to pin-point network trouble location more efficiently and accurately, ultimately reducing the cost of maintenance and repair. The system utilizes probabilistic reasoning techniques and logical operators to determine which plant component has the highest failure probability. This is achieved by building a topology of the local cable network, constructing a causal net which contains belief of failure for each plant component, given their current status, history data, cable pair distribution, and connectivity to other components. The Trouble Localization (TL) Module described in this paper is a crucial part of a larger system: Outside Plant Analysis System (OPAS) which has been deployed Statewide for over nine months at Pacific Bell PMAC centers. The TL system module utilizes AI and Object-Oriented technology. It is implemented in C++ on Unix workstations, and its graphical user interface is in an X Window environment.

  18. New Mexico Minerals Industry Locator System (MILS)

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This contains all Mineral Industry Systems in the state of New Mexico. It is in a vector digital structure digitized from a 1:500,000 scale map of the state of New...

  19. The commodification of location: Dynamics of power in location-based systems

    DEFF Research Database (Denmark)

    Shklovski, Irina; Vertesi, Janet; Troshynski, Emily;

    2009-01-01

    Location-based ubiquitous computing systems are entering mainstream society and becoming familiar parts of everyday life. However, the settings in which they are deployed are already suffused with complex social dynamics. We report on a study of parole officers and parolees whose relationships...... are being transformed by location-based technologies. While parolees are clearly subjects of state discipline, the parole officers also find themselves subject to new responsibilities. This study highlights the complexities of power in sociotechnical systems and what happens when location becomes a tradable...

  20. Outages of electric power supply resulting from cable failures Boston Edison Company system

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-07-01

    Factual data are provided regarding 5 electric power supply interruptions that occurred in the Boston Metropolitan area during April to June, 1979. Common to all of these outages was the failure of an underground cable as the initiating event, followed by multiple equipment failures. There was significant variation in the voltage ratings and types of cables which failed. The investigation was unable to delineate a single specific Boston Edison design operating or maintenance practice that could be cited as the cause of the outages. After reviewing the investigative report the following actions were recommended: the development and implementation of a plan to eliminate the direct current cable network; develop a network outage restoration plan; regroup primary feeder cables wherever possible to minimize the number of circuits in manholes, and to separate feeders to high load density areas; develop a program to detect incipient cable faults; evaluate the separation of the north and south sections of Back Bay network into separate networks; and, as a minimum, install the necessary facilities to make it possible to re-energize one section without interfering with the other; and re-evaluate the cathodic protection scheme where necessary. (LCL)

  1. Study on the model of single cable fault location based on zero sequence DC%基于零序直流原理的单分支故障电缆测距模型的研究

    Institute of Scientific and Technical Information of China (English)

    夏伟伟; 袁振海; 黄锋; 饶日嵩; 徐铮

    2011-01-01

    The conclusion that the linear relationship between the ratio of detective currents and the location of fault cable is drawn by studying the model of single fault cable location based on zero sequence DC, thereby the effect of the power grid voltage fluctuation and fault resistance on the detective current is eliminated. Considering that value of current is small and easy to be disturbed by external signals, a series of measures such as reducing earthing resistance and changing detective resistance are taken to improve the detective accuracy by the method of partial derivative of current ratio with respect to fault location. Based on this, the theory mentioned above is confirmed by simulations and experiments, which indicate the relations between the detective currents and various parameters of model of fault location cable and lay the foundation for further constructing algorithm of single cable fault location.%对近期提出的基于零序直流原理的单分支故障电缆测距模型做了理论分析,提出检测电流的比值与故障电缆距离之间的线性关系,从而消除了电网电压波动和故障电阻对检测电流的影响.考虑到检测电流值很小且容易受外部信号的干扰,进一步将电流比值对故障距离求偏导,指出了减小接地电阻和改变检测电阻值等提高检测精度的措施.在此基础上通过仿真和实验验证了上述理论,揭示了检测电流与故障电缆测距模型中各个参数之间的关系,为进一步构造单分支故障电缆测距算法奠定了基础.

  2. An experimental investigation of the equilibrium and stability of long towed cable systems

    Science.gov (United States)

    Obligado, Martin; Bourgoin, Mickaël

    2013-04-01

    The dynamics of towed objects in a fluid environment is of interest for many practical situations. We investigate experimentally the equilibrium and stability of the trajectory of a sphere towed at constant velocity at the tip of a cable with an unprecedented large length-to-diameter aspect ratio, exceeding 104. The towing configuration is artificially obtained by considering a steady cable (with one fixed end and a free end to which a sphere is eventually attached) in a low-turbulence wind tunnel. We consider three different configurations: (i) the cable towed by itself; (ii) a light millimetric towed sphere made of expanded polystyrene; and (iii) a denser millimetric towed sphere made of lead. The trajectory of the cable tip is monitored using high-speed Lagrangian tracking, which allows one to characterize the average position and the dynamical fluctuations of the towed object. We show that the mean equilibrium position is well predicted by a simple model including the aerodynamical forces acting along the cable and on the towed sphere (when present). Concerning stability issues, we find that the heavy lead particle is always towed in stable conditions (within the accessible range of velocities) with only very low energy oscillations related to a weak pendulum-like motion. In contrast, the free end and light sphere cases are shown to become unstable when the towing velocity exceeds a certain threshold. Spectral analysis shows a flutter-type instability for the sphere, with a dominant oscillatory motion, while the cable alone develops a divergence-type instability with random fluctuations.

  3. Observability of Airborne Passive Location System with Phase Difference Measurements

    Institute of Scientific and Technical Information of China (English)

    Deng Xinpu; Wang Qiang; Zhong Danxing

    2008-01-01

    With a pair of antennas spaced apart, an airborne passive location system measures phase differences of emitting signals. Regarded as cyclic ambiguities, the moduli of the measurements traditionally are resolved by adding more antenna elements. This paper models the cyclic ambiguity as a component of the system state, of which the observability is analyzed and compared to that of the bear- ings-only passive location system. It is shown that the necessary and sufficient observability condition for the bearings-only passive location system is only the necessary observability condition for the passive location system with phase difference measurements, and that when the system state is observable, the cyclic ambiguities can be estimated by accumulating the phase difference measurements, thereby making the observer able to locate the emitter with high-precision.

  4. Research on techniques to improve accuracy in SBL locating systems

    Institute of Scientific and Technical Information of China (English)

    SHI Jie; LIU Bo-sheng; SONG Hai-yan

    2008-01-01

    Short baseline system (SBL), which is a kind of underwater acoustic locating technology, has widely applicable value. In order to examine the capability of ship model design, the ship model experimentation should have high accuracy. This paper focuses on the key techniques of high accuracy locating system, including high accuracy sub-array position emendation, divisional locating, anti multi-path interference measure, etc. Experiments show that the SBL locating systems has received the satisfying effect owing to these key techniques proposed in this paper.

  5. Optical FIBer Intrusion LOCation Sensor System (FIBLOC) for Surface and Subsurface Perimeter Protection. Phase 2

    Science.gov (United States)

    1994-01-01

    barrier sensors. C.3.7 Pressure Sensitive Sensors. An example of a simple pressure sensitive sensor is the familiar air-filled rubber hose stretched across...the location at which an intruder cromsed the perim- A rmdica trama to the semor cable 8, such as one eter of a protectd aes. A light source 2

  6. Study on fault locating technology for satellite power system

    Institute of Scientific and Technical Information of China (English)

    LONG Bing; JIANG Xing-wei; SONG Zheng-ji

    2005-01-01

    It is currently prevalent to locate faults for a satellite power system based on an expert system, not utilizing all the available information provided by tests. The casual network model for a satellite power system is presented. Considerations for failure probability of each component of the power system, the cost of applying each test, the influence of a precedent test result on the next test selection, and an optimal sequential testing algorithm for fault location is presented. This program is applied to locate the failure component of the power system of a satellite. The results show this program is very effective and it is very fast to generate an optimal diagnosis tree.

  7. Long-term monitoring of a cable stayed bridge using a SCADA system

    Science.gov (United States)

    Torbol, Marco; Kim, Sehwan; Shinozuka, Masanobu

    2012-04-01

    DuraMote is a MEMS-based remote sensing system, which is developed for the NIST TIP project, Next Generation SCADA for Prevention and Mitigation of Water System Infrastructure Disaster. It is designed for supervisory control and data acquisition (SCADA) of pipe ruptures in water distribution systems. In this project, a method is developed to detect the pipe ruptures by analyzing the acceleration data gathered by DuraMote which consists of two primary components; the first, "Gopher" contains the accelerometers and are attached to the water pipe surface noninvasively, and the second, "Roocas" is placed above ground supplying the power to, and retrieving the data from the multiple Gophers, and then transmit the data through Wi-Fi to a base station. The relays support the Wi-Fi network to facilitate the transmission. A large scale bridge provides an ideal test-bet to validate the performance of such a complex monitoring system as DuraMote for its accuracy, reliability, robustness, and user friendliness. This is because a large bridge is most of the time subjected to susceptible level of ambient vibration due to passing loads, wind, etc. DuraMote can record the acceleration time history arising from the vibration making it possible to estimate the frequency values of various bridge vibration modes. These estimated frequency values are then compared with the values computed from analytical model of the bridge for the verification of the accuracy of DuraMote. It is noted that such a verification method cannot be used practically by deploying DuraMote on a water distribution network since the dynamic behavior of a pipe network, either above or underground, is too complex to model analytically for this purpose, and in addition, the network generally lacks conveniently recordable ambient vibration. In this experiment, the performance of DuraMote system was tested being installed on the Hwamyung Bridge, a 500 m long RC cable stayed bridge in Korea for long term monitoring. In

  8. 47 CFR 73.685 - Transmitter location and antenna system.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Transmitter location and antenna system. 73.685... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.685 Transmitter location and antenna system... and antenna height above average terrain employed, the following minimum field strength in dB...

  9. Horizon-T Experiment Calibrations - Cables

    CERN Document Server

    Beznosko, D; Iakovlev, A; Makhataeva, Z; Vildanova, M I; Yelshibekov, K; Zhukov, V V

    2016-01-01

    An innovative detector system called Horizon-T is constructed to study Extensive Air Showers (EAS) in the energy range above 1016 eV coming from a wide range of zenith angles (0o - 85o). The system is located at Tien Shan high-altitude Science Station of Lebedev Physical Institute of the Russian Academy of Sciences at approximately 3340 meters above the sea level. The detector consists of eight charged particle detection points separated by the distance up to one kilometer as well as optical detector to view the Vavilov-\\v{C}erenkov light from the EAS. Each detector connects to the Data Acquisition system via cables. The calibration of the time delay for each cable and the signal attenuation is provided in this article.

  10. Calculation and measurement of space charge in MV-size xxtruded cables systems under load conditions

    NARCIS (Netherlands)

    Morshuis, P.H.F.; Bodega, R.; Fabiani, D.; Montanari, G.C.; Dissado, L.A; Smit, J.J.

    2007-01-01

    A load current in dc high voltage cables results in a temperature drop across the insulation and hence a radial distribution of the insulation conductivity is found. Direct consequence is an accumulation of space charge in the bulk of the nsulation, that may significantly affect its reliability. Thi

  11. Haines - Scagway Submarine Cable Intertie Project, Haines to Scagway, Alaska Final Technical and Construction Report

    Energy Technology Data Exchange (ETDEWEB)

    See, Alan; Rinehart, Bennie N; Marin, Glen

    1998-11-01

    The Haines to Skagway submarine cable project is located n Taiya Inlet, at the north end of Lynn Canal, in Southeast Alaska. The cable is approximately 15 miles long, with three landings and splice vaults. The cable is 35 kV, 3-Phase, and armored. The cable interconnects the Goat Lake Hydro Project near Skagway with the community of Haines. Both communities are now on 100% hydroelectric power. The Haines to Skagway submarine cable is the result of AP&T's goal of an alternative, economic, and environmentally friendly energy source for the communities served and to eliminate the use of diesel fuel as the primary source of energy. Diesel units will continue to be used as a backup system.

  12. Improved Method for PD-Quantification in Power Cables

    DEFF Research Database (Denmark)

    Holbøll, Joachim T.; Villefrance, Rasmus; Henriksen, Mogens

    1999-01-01

    n this paper, a method is described for improved quantification of partial discharges(PD) in power cables. The method is suitable for PD-detection and location systems in the MHz-range, where pulse attenuation and distortion along the cable cannot be neglected. The system transfer function...... was calculated and measured in order to form basis for magnitude calculation after each measurements. --- Limitations and capabilities of the method will be discussed and related to relevant field applications of high frequent PD-measurements. --- Methods for increased signal/noise ratio are easily implemented...

  13. Pediatrics and Cable Television.

    Science.gov (United States)

    Wallerstein, Edward; And Others

    The Department of Community Medicine of the Mount Sinai School of Medicine (New York City), in cooperation with the TelePrompTer Corporation and with funding from the Health Services and Mental Health Administration of the Department of Health, Education, and Welfare, has developed a bidirectional television system using coaxial cable which links…

  14. Handbook for photovoltaic cabling

    Energy Technology Data Exchange (ETDEWEB)

    Klein, D. N.

    1980-08-01

    This volume, originally written as part of the Interim Performance Criteria Document Development Implementation Plan and Procedures for Photovoltaic Energy Systems, is an analysis of the several factors to be considered in selecting cabling for photovoltaic purposes. These factors, correspoonding to chapter titles, are electrical, structural, safety, durability/reliability, and installation. A glossary of terms used within the volume is included for reference.

  15. Nonlinear Analysis of Cable Vibration of a Multispan Cable-Stayed Bridge under Transverse Excitation

    OpenAIRE

    Kun Lin; Dujian Zou; Minghai Wei

    2014-01-01

    The nonlinear vibrations of cable in a multispan cable-stayed bridge subjected to transverse excitation are investigated. The MECS (multielements cable system) model, where multielements per cable stay are used, is built up and used to analyze the model properties of the multispan cable-stayed bridges. Then, a simplified two-degrees-of-freedom (2-DOFs) model, where the tower or the deck is reduced to a beam, is proposed to analyze the nonlinear dynamic behaviors of the beam and cable. The res...

  16. A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes

    Directory of Open Access Journals (Sweden)

    M. Brad Eppard

    2011-05-01

    Full Text Available In Part 1 of this paper, we presented the engineering design and instrumentation of the Juvenile Salmon Acoustic Telemetry System (JSATS cabled system, a nonproprietary sensing technology developed by the U.S. Army Corps of Engineers, Portland District (Oregon, USA to meet the needs for monitoring the survival of juvenile salmonids through the hydroelectric facilities within the Federal Columbia River Power System. Here in Part 2, we describe how the JSATS cabled system was employed as a reference sensor network for detecting and tracking juvenile salmon. Time-of-arrival data for valid detections on four hydrophones were used to solve for the three-dimensional (3D position of fish surgically implanted with JSATS acoustic transmitters. Validation tests demonstrated high accuracy of 3D tracking up to 100 m upstream from the John Day Dam spillway. The along-dam component, used for assigning the route of fish passage, had the highest accuracy; the median errors ranged from 0.02 to 0.22 m, and root mean square errors ranged from 0.07 to 0.56 m at distances up to 100 m. For the 2008 case study at John Day Dam, the range for 3D tracking was more than 100 m upstream of the dam face where hydrophones were deployed, and detection and tracking probabilities of fish tagged with JSATS acoustic transmitters were higher than 98%. JSATS cabled systems have been successfully deployed on several major dams to acquire information for salmon protection and for development of more “fish-friendly” hydroelectric facilities.

  17. North American Submarine Cable Association (NASCA) Submarine Cables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data show the locations of in-service and out-of-service submarine cables that are owned by members of NASCA and located in U.S. territorial waters. More...

  18. A Wearable Computing System for Dynamic Locating of Parking Spaces

    Directory of Open Access Journals (Sweden)

    Damian Mrugala

    2010-07-01

    Full Text Available This paper describes a dynamic locating system implemented in an autonomous wearable computing system for the automobile warehouse management application. Since the first prototype is developed as jacket [1], this prototype is miniaturized and therefore realized as holster which consists of several modules for identification, communication and localization. It is worn by employees during warehousing of automobiles. The modules collect data, which are used by the operating system to calculate the location of parking spaces dynamically.

  19. Submerged Medium Voltage Cable Systems at Nuclear Power Plants. A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bernstein, Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); White, II, Gregory Von [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Glover, Steven F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neely, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pena, Gary [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Williamson, Kenneth Martin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zutavern, Fred J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gelbard, Fred [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    and industrial literature was performed to identify : 1) findings regarding the degradation mechanisms of submerged cabling and 2) condition monitoring methods that may prove useful in predict ing the remaining lifetime of submerged medium voltage p ower cables . The re search was conducted by a multi - disciplinary team , and s ources includ ed official NRC reports, n ational l aboratory reports , IEEE standards, conference and journal proceedings , magazine articles , PhD dissertations , and discussions with experts . The purpose of this work was to establish the current state - of - the - art in material degradation modeling and cable condition monitoring techniques and to identify research gaps . Subsequently, future areas of focus are recommended to address these research gaps and thus strengthen the efficacy of the NRC's developing cable condition monitoring program . Results of this literature review and details of the test ing recommendations are presented in this report . FOREWORD To ensure the safe, re liable, and cost - effective long - term operation of nuclear power plants, many systems, structures, and components must be continuously evaluated. The Nuclear Regulatory Commission (NRC) has identified that cables in submerged environments are of concern, particularly as plants are seeking license renewal. To date, there is a lack of consensus on aging and degradation mechanisms even though the area of submerged cables has been extensively studied. Consequently, the ability to make lifetime predictions for submerged cable does not yet exist. The NRC has engaged Sandia National Laboratories (SNL) to lead a coordinated effort to help elucidate the aging and degradation of cables in submerged environments by collaborating with cable manufacturers, utilities, universities, and other government agencies. A team of SNL experts was assembled from the laboratories including electrical condition monitoring, mat erial science, polymer degradation, plasma physics

  20. TWRS information locator database system administrator`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Knutson, B.J., Westinghouse Hanford

    1996-09-13

    This document is a guide for use by the Tank Waste Remediation System (TWRS) Information Locator Database (ILD) System Administrator. The TWRS ILD System is an inventory of information used in the TWRS Systems Engineering process to represent the TWRS Technical Baseline. The inventory is maintained in the form of a relational database developed in Paradox 4.5.

  1. Cable Harness Assembly Planning in Virtual Environment

    Institute of Scientific and Technical Information of China (English)

    LIU Jianhua; NING Ruxin; BAI Shuqing; WANG Bile

    2006-01-01

    Based on the analysis of characteristic of cable harness planning in virtual environment, a discrete control node modeling (DCNM) method of cable harness in virtual environment and the cable harness assembly routing technique based on it are proposed. DCNM converts a cable harness into continuous flexed line segments connected by a series of section center points, and the design can realize cable harness planning through controlling those control nodes. This method of cable harness routing in the virtual environment breaks the status that virtual assembly process planning is just suitable for the rigid components at present, and impulse the virtual assembly process planning to be more practical. Relation algorithms have been verified in a self-developed system named virtual cable harness assembly planning (VCHAP) system, and this VCHAP system has been applied in assembly process planning of aerospace-related products.

  2. Internal Location Based System for Mobile Devices Using Passive RFID

    CERN Document Server

    Vhatkar, Kapil N

    2010-01-01

    We have explored our own innovative work about the design & development of internal location-identification system for mobile devices based on integration of RFID and wireless technology. The function of our system is based on strategically located passive RFID tags placed on objects around building which are identified using an RFID reader attached to a mobile device. The mobile device reads the RFID tag and through the wireless network, sends the request to the server. The server resolves the request and sends the desired location-based information back to the mobile device. We had addressed that we can go through the RFID technology for internal location identification (indoor), which provides us better location accuracy because of no contact between the tag and the reader, and the system requires no line of sight. In this paper we had also focused on the issues of RFID technologies i.e. Non-line-of-sight & High inventory speeds.

  3. Fault Location Method of Underground Cable Based on Wavelet Analysis and Neural Network%基于小波分析和神经网络的井下电缆故障测距方法

    Institute of Scientific and Technical Information of China (English)

    田书; 赵敏

    2012-01-01

    In order to solve problems of poor reliability and accuracy of existing fault location methods of underground cable, the paper introduced a fault location method of underground cable based on wavelet analysis and neural network, and compared performance of BP neural network and RBF neural network used in the method. The method uses 3B-spline semi-orthogonal wavelet to do wavelet transformation for transient-state zero-sequence current so as to get modulus maxima of transient-state zero-sequence current in specific frequency bands. The modulus maxima is taken as inputting signals of neural network, and realizes fault location according to mapping relationship between the modulus maxima and position of fault point. The simulation results showed that the method can realize fault location of underground cable, and the method with RBP neural network is better than BF neural network in location error and network training.%针对现有的井下电缆故障测距方法存在可靠性差、精度低的问题,介绍了一种基于小波分析理论和神经网络的井下电缆故障测距方法,并比较了BP神经网络和RBF神经网络用于该方法的测距性能.该故障测距方法采用3次B样条半正交小波对暂态零序电流信号进行小波变换,得到特定频带内的暂态零序电流模极大值,并将该模极大值作为神经网络的输入信号,根据模极大值与故障点位置的映射关系实现故障定位.仿真结果表明,该故障测距方法能够较好地进行井下电缆故障测距,且RBF神经网络的测距误差及训练速度均优于BP神经网络.

  4. 连续油管电缆安装系统的开发%Development of a Coiled Tubing Cable Installation System

    Institute of Scientific and Technical Information of China (English)

    杨社民

    2015-01-01

    A system has been developed which installs and de-installs an electric wireline cable in Coiled Tubing (CT) while the CT is still on the reel. This paper discuss the need for such a system, the theory used to develop this system, the various concepts considered, the system that was developed and test installation cases. The working pressure of this cable installation system is 51.72 MPa(7 500 psi). This cable installation system reduces the cost of a cable installation significantly compared with previous installation methods, and can fully meet the requiremetns of installation cable in long coiled tubing.%开发出了一个可以缠绕在卷筒上的连续油管内注入、注出电力电缆安装系统。介绍了该安装系统的油田需求、开发此系统所用理论、该安装系统的各部分装置以及应用案例。该电缆安装系统工作压力为51.72 MPa(7500 psi),与以前的安装方法相比,大大降低了电缆安装成本,完全满足在较长连续油管内安装电缆的需求。

  5. Nonlinear distortion evaluation in a directly modulated distributed feedback laser diode-based fiber-optic cable television transport system

    Science.gov (United States)

    Li, Chung-Yi; Ying, Cheng-Ling; Lin, Chun-Yu; Chu, Chien-An

    2015-12-01

    This study evaluated a directly modulated distributed feedback (DFB) laser diode (LD) for cable TV systems with respect to carrier-to-nonlinear distortion of LDs. The second-order distortion-to-carrier ratio is found to be proportional to that of the second-order coefficient-to-first-order coefficient of the DFB laser diode driving current and to the optical modulation index (OMI). Furthermore, the third-order distortion-to-carrier ratio is proportional to that of the third-order coefficient-to-first-order coefficient of the DFB laser diode driving current, and to the OMI2.

  6. Development of sensor system for indoor location based service implementation

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Joo Heon; Lee, Kyung Ho [Kookmin Univ., Seoul (Korea, Republic of)

    2012-11-15

    This paper introduces a sensor system based on indoor locations in order to implement the Building Energy Management System. This system consists of a thermopile sensor and an ultrasonic sensor. The sensor module is rotated by 360 .deg. and yawed up and down by two electric motors. Therefore, it can simultaneously detect the number and location of the inhabitants in the room. It uses wireless technology to communicate with the building manager or the smart home server, and it can save electric energy by controlling the lighting system or heating/air conditioning equipment automatically. We also demonstrate the usefulness of the proposed system by applying it to a real environment.

  7. Location Update Accuracy in Human Tracking system using Zigbee modules

    CERN Document Server

    Amutha, B

    2009-01-01

    A location and tracking system becomes very important to our future world of pervasive computing. An algorithm for accurate location information is being incorporated in the human walking model and in the blind human walking model. We want to implement an accurate location tracking mechanism using Zigbee along with GPS, we have incorporated Markov chain algorithm for establishing accuracy. Normal Human and blind human walking steps were actually taken in the known environment within our campus and the Markov chain algorithm was used for smoothening the stepwise variation in location updates. A comparison module is also implemented to show the difference between normal human and blind human walking step variations. This accuracy is used for designing a blind tracking device so that the device can be used by the blind for finding the path without obstacles. We present a system level approach to localizing and tracking Human and blind users on a basis of different sources of location information [GPS plus Zigbee...

  8. Cable Sliding at Supports in Cable Structures

    Institute of Scientific and Technical Information of China (English)

    魏建东

    2004-01-01

    To develop an effective numerical method for the cable sliding problem in cable structures, two-node catenary cable element was built to model the cables based on analytical solution of elastic catenary. Cooperated with Newton method, continuation method was used to solve the nonlinear equations. This approach is more efficient than using Newton method only and has a wider range to select initial values for the process to converge. The relationship between the tension on a cable segment and its unstrained length was derived and used to calculate the unbalanced cable tensions at the supports. An example is presented to show the correctness and efficiency of the proposed method.

  9. Fault Location in Power Electrical Traction Line System

    Directory of Open Access Journals (Sweden)

    Yimin Zhou

    2012-11-01

    Full Text Available In this paper, methods of fault location are discussed in electrical traction single-end direct power supply network systems. Based on the distributed parameter model of the system, the position of the short-circuit fault can be located with the aid of the current and voltage value at the measurement end of the electrical traction line. Furthermore, the influence of the transient resistance, the position of the locomotive, locomotive load for fault location are also discussed. MATLAB simulation tool is used for the simulation experiments. Simulation results are proved the effectiveness of the proposed algorithms.

  10. Seismic Passive Control of Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    Hosam-Eddin M. Ali

    1995-01-01

    Full Text Available A three-dimensional modeling procedure is proposed for cable-stayed bridges with rubber, steel, and lead energy dissipation devices. The passive control technique is investigated by considering the response of bridge models with and without energy dissipation devices. The impact of various design parameters on the seismic response of current and future bridge designs is studied. Appropriate locations and properties of the passive devices can achieve better performance for cable-stayed bridges by balancing the significant reduction in earthquake-induced forces against tolerable displacements. Proper design of passive systems can help provide solutions for retro-fitting some existing bridges.

  11. Optimal Sensor and Actuator Location for Unstable Systems

    DEFF Research Database (Denmark)

    Shaker, Hamid Reza; Tahavori, Maryamsadat

    2013-01-01

    on the processes. Dually the problem of placing actuators on the processes is equally important. In this paper, the problem of determining optimal sensor and actuator locations for the linear systems is addressed. The problem of the sensor locations is viewed as the problem of maximizing the output energy...... proposed so far, only support stable systems. However, in industrial practices it is often the case that the system, which is needed to be controlled, is not stable. The method which is proposed in this paper is a general method in the sense that it supports both stable and unstable systems. The technique...

  12. Location tracking system using wearable on-body GPS antenna

    Directory of Open Access Journals (Sweden)

    Sabapathy Thennarasan

    2017-01-01

    Full Text Available An on-body location tracking system is developed and integrated with a wearable GPS antenna. Such system is beneficial in human location tracking of patients and elderly within a radius of 1 km. The system consists of a wearable antenna, a GPS module, a low cost microcontroller, two RF modules and a local monitoring system. A user equipped with the GPS antenna, GPS module and a RF transmitter is able send his/her location to the local monitoring system via a RF receiver. The proposed wearable antenna is validated to be safe for human use in terms of specific absorption rate (SAR. This antenna was then incorporated into the complete prototype and tested. Several suggestions for future improvements are also proposed and discussed.

  13. Online location of seismic damage to a water distribution system

    Institute of Scientific and Technical Information of China (English)

    梁建文

    2003-01-01

    As one of the most important urban lifeline systems, a water distribution system can be damaged under a strong earthquake, and the damage cannot easily be located, especially immediately after the event. This often causes tremendous difficulties to post-earthquake emergency response and recovery activities. This paper proposes a methodology to locate seismic damage to a water distribution system by monitoring watcr head online at some nodes in the water distribution system. An artificial neural network-based inverse analysis method is developed to estimate the water head variations at all nodes that are not monitored based on the water head variations at the nodes that are monitored. The methodology provides a quick, effective, and practical way to locate seismic damage to a water distribution system.

  14. Gjoea power cable; a green solution

    Energy Technology Data Exchange (ETDEWEB)

    Dretvik, Svein-Egil

    2010-07-01

    An alternative to today's power generation offshore using either gas or diesel, is alternating current (AC) electric power cable from shore. The power from shore through the AC cable gives high savings for the environment. The cable replaces 4 gas turbines with a total CO2 disposal of 240 00 tonnes each year which represents the disposal of 100 000 cars. ABB was awarded the contract which includes engineering, fabrication and installation of the power cable from Mongstad to the Gjoea platform which will be the longest AC cable in the world with a total length of 100 km. The presentation will include system design, qualification of dynamic power cable, cable fabrication experiences, testing at fabrication yard and installation aspects. (Author)

  15. Research on Construction Monitoring Techniques for Cable Replacement of the Cable-Stayed Bridge

    Directory of Open Access Journals (Sweden)

    Dai Pu

    2013-09-01

    Full Text Available Due to various reasons, some cable-stayed bridges require the replacement of part or all stay cables after operating for a period of time. In this study, based on some engineering practices of stay cable replacement, the condition of bridge structure before replacement is analyzed with Finite Element Analysis method for plane member system. The theoretical calculations, cable force measurement, replacement methods and process monitoring for cable replacement are introduced to find out the key technical problems. From the specified bridge monitoring practices, we suggest monitoring cable tension and the main beam alignment during the process of cable replacement, to make sure the cable-stayed bridge reaches its design conditions.

  16. Optimization of Regulation Valve Location for Heating System

    Institute of Scientific and Technical Information of China (English)

    LIU Ling-ling; CHEN Hong-bing; LI De-ying

    2009-01-01

    This paper mainly studied how to determine the best location of the self-operated flow control valve at the heating system entrance.Since the location of regulating valve directly affects the pipe network per-formance,the simulation and analysis of pressure change in heating system WaS carried out with ComputationalFluid Dynamics(CFD)software.The study shows the best location of regulating valve varies with the change of the supply and return pipe length when the heating area of each user is small,and when the heating area of each user is large(2000000~3000000m2),the best location is on the supply pipe.

  17. Tapping the television cable.

    Science.gov (United States)

    Clarke, M; Findlay, A; Canac, J F; Vergez, A

    1996-01-01

    Immediate access to patient data is essential to support good clinical decision making and support. However, away from the surgery, the doctor is currently unable to have any access to the clinical database. Solutions exist to support remote access, such as modems or radio data networks, but these are slow, with typical speeds in the 2-10 kbaud region. We propose a novel solution, to use the TV cable already installed in many homes. Using this technology, a suitably equipped computer (RF modern) is capable of connecting at speeds in excess of 500 kbaud and will run applications in exactly the same way as if connected to a surgery network: the cable TV becomes a LAN, but on a metropolitan scale. Brunel University, in collaboration with the Cable Corporation, has been piloting such a network. Issues include not only levels of service, but also security on the network and access, since the data are being effectively received in every home. However, close scrutiny of channel use can create closed networks reserved for specific users. The technology involves use of an RF modem to transmit data on a reverse channel (based at 16 MHz) on each subnet to a router at the head end of the cable network. This frequency translates the packet and retransmits it to all the subnets on a forward channel (based at 178 MHz). Each channel occupies the bandwidth normally allocated to one TV channel. Access is based on a modified CSMA/CD protocol, so treating the cable network as single multiple access network. The modem comes as a standard card installed in a PC and appears much as an ethernet card, but at reduced speed. With an NDIS driver it is quite able to support almost any network software, and has successfully demonstrated Novell and TCP/IP. We describe the HomeWorker network and the results from a pilot study being undertaken to determine the performance of the system and its impact on working practice.

  18. Submerged Medium Voltage Cable Systems at Nuclear Power Plants. A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bernstein, Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); White, II, Gregory Von [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Glover, Steven F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neely, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pena, Gary [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Williamson, Kenneth Martin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zutavern, Fred J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gelbard, Fred [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    and industrial literature was performed to identify : 1) findings regarding the degradation mechanisms of submerged cabling and 2) condition monitoring methods that may prove useful in predict ing the remaining lifetime of submerged medium voltage p ower cables . The re search was conducted by a multi - disciplinary team , and s ources includ ed official NRC reports, n ational l aboratory reports , IEEE standards, conference and journal proceedings , magazine articles , PhD dissertations , and discussions with experts . The purpose of this work was to establish the current state - of - the - art in material degradation modeling and cable condition monitoring techniques and to identify research gaps . Subsequently, future areas of focus are recommended to address these research gaps and thus strengthen the efficacy of the NRC's developing cable condition monitoring program . Results of this literature review and details of the test ing recommendations are presented in this report . FOREWORD To ensure the safe, re liable, and cost - effective long - term operation of nuclear power plants, many systems, structures, and components must be continuously evaluated. The Nuclear Regulatory Commission (NRC) has identified that cables in submerged environments are of concern, particularly as plants are seeking license renewal. To date, there is a lack of consensus on aging and degradation mechanisms even though the area of submerged cables has been extensively studied. Consequently, the ability to make lifetime predictions for submerged cable does not yet exist. The NRC has engaged Sandia National Laboratories (SNL) to lead a coordinated effort to help elucidate the aging and degradation of cables in submerged environments by collaborating with cable manufacturers, utilities, universities, and other government agencies. A team of SNL experts was assembled from the laboratories including electrical condition monitoring, mat erial science, polymer degradation, plasma physics

  19. Fault-Tolerant Systems with Concurrent Error-Locating Capability

    Institute of Scientific and Technical Information of China (English)

    JIANG JianHui(江建慧); MIN YingHua(闵应骅); PENG ChengLian(彭澄廉)

    2003-01-01

    Fault-tolerant systems have found wide applications in military, industrial andcommercial areas. Most of these systems are constructed by multiple-modular redundancy or er-ror control coding techniques. They need some fault-tolerant specific components (such as voter,switcher, encoder, or decoder) to implement error-detecting or error-correcting functions. However,the problem of error detection, location or correction for fault-tolerance specific components them-selves has not been solved properly so far. Thus, the dependability of a whole fault-tolerant systemwill be greatly affected. This paper presents a theory of robust fault-masking digital circuits forcharacterizing fault-tolerant systems with the ability of concurrent error location and a new schemeof dual-modular redundant systems with partially robust fault-masking property. A basic robustfault-masking circuit is composed of a basic functional circuit and an error-locating corrector. Sucha circuit not only has the ability of concurrent error correction, but also has the ability of concurrenterror location. According to this circuit model, for a partially robust fault-masking dual-modularredundant system, two redundant modules based on alternating-complementary logic consist of thebasic functional circuit. An error-correction specific circuit named as alternating-complementarycorrector is used as the error-locating corrector. The performance (such as hardware complexity,time delay) of the scheme is analyzed.

  20. Understanding losses in three core armoured submarine cables

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Ebdrup, Thomas; Bak, Claus Leth

    2016-01-01

    . For practical an economical reasons the preferred choice of cable for both the array and the transmission cables are three-core armoured submarine cables. Therefore, it has becoming increasingly important to be able to calculate the ampacity of such cables accurately. At present time, the ampacity of three......-core armoured submarine cables is calculated according to IEC 60287-1-1 [1]. Various measurements conducted both by cable manufacturers and transmission system operators (TSO) have shown that using the cable rating method stated in IEC 60287-1-1 underestimates the cable ampacity [2]-[6]. Furthermore....... However, research performed in this paper shows that while the armour is responsible for the extra losses, the main calculation error for typical HVAC submarine cables may be in the screen’s loss factor (λ1). Overestimation of the cable losses may result in core cross-sections too large with more material...

  1. Cable Television Service; Cable Television Relay Service.

    Science.gov (United States)

    Federal Register, 1972

    1972-01-01

    The rules and regulations of the Federal Communications Commission (FCC) concerning cable television service and cable relay service are presented along with the comments of the National Cable Television Association, the National Association of Broadcasters, the Association of Maximum Service Telecasters, and a major group of program suppliers.…

  2. Emergency Locator Transmitter System Performance During Three Full-Scale General Aviation Crash Tests

    Science.gov (United States)

    Littell, Justin D.; Stimson, Chad M.

    2016-01-01

    Full-scale crash tests were conducted on three Cessna 172 aircraft at NASA Langley Research Center's Landing and Impact Research facility during the summer of 2015. The purpose of the three tests was to evaluate the performance of commercially available Emergency Locator Transmitter (ELT) systems and support development of enhanced installation guidance. ELTs are used to provide location information to Search and Rescue (SAR) organizations in the event of an aviation distress situation, such as a crash. The crash tests simulated three differing severe but survivable crash conditions, in which it is expected that the onboard occupants have a reasonable chance of surviving the accident and would require assistance from SAR personnel. The first simulated an emergency landing onto a rigid surface, while the second and third simulated controlled flight into terrain. Multiple ELT systems were installed on each airplane according to federal regulations. The majority of the ELT systems performed nominally. In the systems which did not activate, post-test disassembly and inspection offered guidance for non-activation cause in some cases, while in others, no specific cause could be found. In a subset of installations purposely disregarding best practice guidelines, failure of the ELT-to-antenna cabling connections were found. Recommendations for enhanced installation guidance of ELT systems will be made to the Radio Technical Commission for Aeronautics (RTCA) Special Committee 229 for consideration for adoption in a future release of ELT minimum operational performance specifications. These recommendations will be based on the data gathered during this test series as well as a larger series of crash simulations using computer models that will be calibrated based on these data

  3. Architecture for Multi-Technology Real-Time Location Systems

    Directory of Open Access Journals (Sweden)

    Javier Rodas

    2013-02-01

    Full Text Available The rising popularity of location-based services has prompted considerable research in the field of indoor location systems. Since there is no single technology to support these systems, it is necessary to consider the fusion of the information coming from heterogeneous sensors. This paper presents a software architecture designed for a hybrid location system where we can merge information from multiple sensor technologies. The architecture was designed to be used by different kinds of actors independently and with mutual transparency: hardware administrators, algorithm developers and user applications. The paper presents the architecture design, work-flow, case study examples and some results to show how different technologies can be exploited to obtain a good estimation of a target position.

  4. A Wearable Computing System for Dynamic Locating of Parking Spaces

    OpenAIRE

    Damian Mrugala; Alexander Dannies; Walter Lang

    2010-01-01

    This paper describes a dynamic locating system implemented in an autonomous wearable computing system for the automobile warehouse management application. Since the first prototype is developed as jacket [1], this prototype is miniaturized and therefore realized as holster which consists of several modules for identification, communication and localization. It is worn by employees during warehousing of automobiles. The modules collect data, which are used by the operating system to calculate ...

  5. An Optimization Model for Fiber-Optic Cable Installation Aboard Naval Vessels

    Science.gov (United States)

    2013-06-01

    of the most impressive components of Site B’s cable installation process was their real time tracking system. When a cable arrives at the shipyard...This is important because fiber-optic cables can be run in the same wireways or trays as heavier power cable (Cables Plus USA). 2. Specification Value

  6. Cable Tensiometer for Aircraft

    Science.gov (United States)

    Nunnelee, Mark (Inventor)

    2008-01-01

    The invention is a cable tensiometer that can be used on aircraft for real-time, in-flight cable tension measurements. The invention can be used on any aircraft cables with high precision. The invention is extremely light-weight, hangs on the cable being tested and uses a dual bending beam design with a high mill-volt output to determine tension.

  7. Full-scale fire experiments on vertical horizontal cable trays

    Energy Technology Data Exchange (ETDEWEB)

    Mangs, J.; Keski-Rahkonen, O. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1997-10-01

    Two full-scale fire experiments on PVC cables used in nuclear power plants were carried out, one with cables in vertical position and one with cables in horizontal position. The vertical cable bundle, 3 m high, 300 mm wide and 30 mm thick, was attached to a steel cable ladder. The vertical bundle experiment was carried out in nearly free space with three walls near the cable ladder guiding air flow in order to stabilise flames. The horizontal cable experiment was carried out in a small room with five cable bundles attached to steel cable ladders. Three of the 2 m long cable bundles were located in an array, equally spaced above each other near one long side of the room and two correspondingly near the opposite long side. The vertical cable bundle was ignited with a small propane gas burner beneath the lower edge of the bundle. The horizontal cable bundles were ignited with a small propane burner beneath the lowest bundle in an array of three bundles. Rate of heat release by means of oxygen consumption calorimetry, mass change, CO{sub 2}, CO and smoke production rate and gas, wall and cable surface temperatures were measured as a function of time, as well as time to sprinkler operation and failure of test voltage in cables. Additionally, the minimum rate of heat release needed to ignite the bundle was determined. This paper concentrates on describing and recording the experimental set-up and the data obtained. (orig.)

  8. Emergency Department Real Time Location System Patient and Equipment Tracking

    Science.gov (United States)

    2013-10-01

    solution complies with all RF transmission guidelines to avoid interference with Hospital’s wireless communication systems and clinical...technology path that the messages will follow is, AgileTrac ESB services will capture real time updates of patient locations and push that

  9. GSM Base Stations Location Monitoring using Geographic Information System

    Directory of Open Access Journals (Sweden)

    Kuboye B. M.

    2013-06-01

    Full Text Available Global System for Mobile Communication (GSM is a digital system developed to meet the desires of the entire public. As the population of a particular area, city or country increases, the number of mobile subscribers increases too. GSM network operators have to reduce congestion on their networks in order to satisfy their subscribers, therefore, a means of monitoring the base stations' locations and the geographical area of where they are located are important factor to achieve this purpose. This work provides a simple step-by-step approach on how to monitor the location of the base stations. A review of GSM and Global Positioning System (GPS technology and their applications to the Geographic Information System (GIS are presented. The means of taken the coordinates of base stations using a GPS device is also presented. ESRI's ArcView application software was used to design the map that shows the location of the base station and thereafter was integrated into the web. It concluded with the recommendation to GSM operators in Nigeria. If the recommendations are given necessary attention, the planning and optimization of cell sites will be enhanced and thereby reduce congestion on network. As a result, the performance of Network will improve, and it will give rise to subscribers' satisfaction and increasing profit returns to the operators.

  10. Measuring long-term location privacy in vehicular communication systems

    NARCIS (Netherlands)

    Ma, Zhendong; Kargl, Frank; Weber, Michael

    2010-01-01

    Vehicular communication systems are an emerging form of communication that enables new ways of cooperation among vehicles, traffic operators, and service providers. However, many vehicular applications rely on continuous and detailed location information of the vehicles, which has the potential to i

  11. MARVEL: A System for Recognizing World Locations with Stereo Vision

    Science.gov (United States)

    1990-05-01

    Baxandall 1983]) to plan their daily commutes or vacation excursions. 147 148 CHAPTER 9. LOCATION RECOGNITION AND THE WORFLD MODEL 9.1 Introduction...Inc. 1982. Baxandall , L. World Guide to Nude Beaches and Recreation. New York: Harmony Books. 1983. Binford, T. 0. Survey of stereo mapping systems

  12. Carbon Fiber Reinforced Polymer for Cable Structures—A Review

    Directory of Open Access Journals (Sweden)

    Yue Liu

    2015-10-01

    Full Text Available Carbon Fiber Reinforced Polymer (CFRP is an advanced composite material with the advantages of high strength, lightweight, no corrosion and excellent fatigue resistance. Therefore, unidirectional CFRP has great potential for cables and to replace steel cables in cable structures. However, CFRP is a typical orthotropic material and its strength and modulus perpendicular to the fiber direction are much lower than those in the fiber direction, which brings a challenge for anchoring CFRP cables. This paper presents an overview of application of CFRP cables in cable structures, including historical review, state of the art and prospects for the future. After introducing properties of carbon fibers, mechanical characteristics and structural forms of CFRP cables, existing CFRP cable structures in the world (all of them are cable bridges are reviewed. Especially, their CFRP cable anchorages are presented in detail. New applications for CFRP cables, i.e., cable roofs and cable facades, are also presented, including the introduction of a prototype CFRP cable roof and the conceptual design of a novel structure—CFRP Continuous Band Winding System. In addition, other challenges that impede widespread application of CFRP cable structures are briefly introduced.

  13. System Finds Horizontal Location of Center of Gravity

    Science.gov (United States)

    Johnston, Albert S.; Howard, Richard T.; Brewster, Linda L.

    2006-01-01

    An instrumentation system rapidly and repeatedly determines the horizontal location of the center of gravity of a laboratory vehicle that slides horizontally on three air bearings (see Figure 1). Typically, knowledge of the horizontal center-of-mass location of such a vehicle is needed in order to balance the vehicle properly for an experiment and/or to assess the dynamic behavior of the vehicle. The system includes a load cell above each air bearing, electronic circuits that generate digital readings of the weight on each load cell, and a computer equipped with software that processes the readings. The total weight and, hence, the mass of the vehicle are computed from the sum of the load-cell weight readings. Then the horizontal position of the center of gravity is calculated straightforwardly as the weighted sum of the known position vectors of the air bearings, the contribution of each bearing being proportional to the weight on that bearing. In the initial application for which this system was devised, the center- of-mass calculation is particularly simple because the air bearings are located at corners of an equilateral triangle. However, the system is not restricted to this simple geometry. The system acquires and processes weight readings at a rate of 800 Hz for each load cell. The total weight and the horizontal location of the center of gravity are updated at a rate of 800/3 approx. equals 267 Hz. In a typical application, a technician would use the center-of-mass output of this instrumentation system as a guide to the manual placement of small weights on the vehicle to shift the center of gravity to a desired horizontal position. Usually, the desired horizontal position is that of the geometric center. Alternatively, this instrumentation system could be used to provide position feedback for a control system that would cause weights to be shifted automatically (see Figure 2) in an effort to keep the center of gravity at the geometric center.

  14. Location-aware News Recommendation System with Using Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    Mehdi Nejati

    2016-10-01

    Full Text Available with release of a huge amount of news on the Internet and the trend of users to Web-based news services.it is necessary to have a recommendation system. To grab attentions to news, news services use a number of criteria that called news values and user location is an important factor for it. In this paper, LONEF is proposed as a tow stage recommendation system. In first stage news are ranked by user’s locations and in second stage news are recommended by location Preferences, recency, Trustworthiness, groups priorities and popularity. To reduce ambiguity these properties is used tow Mamdani fuzzy interference and case-based decision systems. In Mamdani fuzzy interference system, it is tried to increase the system speed by optimizing selection of rules and membership functions and because of ambiguous feedback implementation, a decision making system is used to enable better simulation of user’s activities. Performance of our proposed approach is demonstrated in the experiments on different news groups.

  15. A system for coarse-grained location-based synchronisation

    CERN Document Server

    Coelho, André; Silva, Mário; José, Rui

    2010-01-01

    This paper describes a system for supporting coarse-grained location-based synchronisation. This type of synchronisation may occur when people need only some awareness about the location of others within the specific context of an on-going activity. We have identified a number of reference scenarios for this type of synchronisation and we have implemented and deployed a prototype to evaluate the type of support provided. The results of the evaluation suggest a good acceptance of the overall concept, indicating that this might be a valuable approach for many of the indicated scenarios, possibly replacing or complementing existing synchronisation practices.

  16. Results from the Danish high temperature superconducting power cable project

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob

    2002-01-01

    For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying approxim......For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying...

  17. Location-based resource allocation for OFDMA cognitive radio systems

    KAUST Repository

    Nam, Haewoon

    2010-01-01

    In cognitive radio systems, in order for the secondary users to opportunistically share the spectrum without interfering the primary users, an accurate spectrum measurement and a precise estimation of the interference at the primary users are necessary but are challenging tasks. Since it is impractical in cognitive radio systems to assume that the channel state information of the interference link is available at the cognitive transmitter, the interference at the primary users is hard to be estimated accurately. This paper introduces a resource allocation algorithm for OFDMA-based cognitive radio systems, which utilizes location information of the primary and secondary users instead of the channel state information of the interference link. Simulation results show that it is indeed effective to incorporate location information into resource allocation so that a near-optimal capacity is achieved.

  18. Lightning location system supervising Swedish power transmission network

    Science.gov (United States)

    Melin, Stefan A.

    1991-01-01

    For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

  19. Using Kalman filters to reduce noise from RFID location system.

    Science.gov (United States)

    Abreu, Pedro Henriques; Xavier, José; Silva, Daniel Castro; Reis, Luís Paulo; Petry, Marcelo

    2014-01-01

    Nowadays, there are many technologies that support location systems involving intrusive and nonintrusive equipment and also varying in terms of precision, range, and cost. However, the developers some time neglect the noise introduced by these systems, which prevents these systems from reaching their full potential. Focused on this problem, in this research work a comparison study between three different filters was performed in order to reduce the noise introduced by a location system based on RFID UWB technology with an associated error of approximately 18 cm. To achieve this goal, a set of experiments was devised and executed using a miniature train moving at constant velocity in a scenario with two distinct shapes-linear and oval. Also, this train was equipped with a varying number of active tags. The obtained results proved that the Kalman Filter achieved better results when compared to the other two filters. Also, this filter increases the performance of the location system by 15% and 12% for the linear and oval paths respectively, when using one tag. For a multiple tags and oval shape similar results were obtained (11-13% of improvement).

  20. Braided tubular superelastic cables provide improved spinal stability compared to multifilament sublaminar cables.

    Science.gov (United States)

    Tremblay, Jaëlle; Mac-Thiong, Jean-Marc; Brailovski, Vladimir; Petit, Yvan

    2015-09-01

    This study investigates the use of braided tubular superelastic cables, previously used for sternum closure following sternotomy, as sublaminar fixation method. It compares the biomechanical performance of spinal instrumentation fixation systems with regular sublaminar cables and proprietary superelastic cables. A hybrid experimental protocol was applied to six porcine L1-L4 spinal segments to compare multifilament sublaminar cables (Atlas, Medtronic Sofamor Danek, Memphis, TN) with proprietary superelastic cables. First, intact total range of motion was determined for all specimens using pure moment loading. Second, pure moments were imposed to the instrumented specimens until these intact total ranges of motion were reproduced. Compared to the intact specimens, the use of superelastic cables resulted in stiffer instrumented specimens than the use of multifilament cables for all the loading modes except axial torsion. Consequently, the superelastic cables limited the instrumented segments mobility more than the multifilament cables. Spinal instrumentation fixation systems using superelastic cables could be a good alternative to conventional sublaminar cables as it maintains a constant stabilization of the spine during loading.

  1. Brookhaven superconducting cable test facility

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, E.B.; Gibbs, R.J.

    1976-08-17

    Construction has started on an outdoor testing station for flexible ac superconducting power transmission cables. It is intended to serve as an intermediate step between laboratory-scale experiments and qualification testing of prototype-scale cables. The permanent equipment includes a 500 W supercritical helium refrigerator using a screw compressor and multistage turbine expanders. Helium storage for 250,000 cu ft of helium at 250 psi is provided. Initially, the cables will be tested in a horizontal cryostat some 250 ft long. High-voltage 60 Hz tests will be performed with the cable in a series resonant mode with a maximum line to ground capability of 240 kV, this is adequate for a 138 kV system design. Impulse testing up to about 650 kV is planned. The cable conductor will be energized by current transformers, initially at about 4 kA and later up to fault levels of 40 kA. The refrigerator is now at the site and testing on a dummy load will commence in the Fall of 1976. The cryostat will be installed in 1977 followed about a year later by the first cable tests.

  2. Design of a TDOA location engine and development of a location system based on chirp spread spectrum.

    Science.gov (United States)

    Wang, Rui-Rong; Yu, Xiao-Qing; Zheng, Shu-Wang; Ye, Yang

    2016-01-01

    Location based services (LBS) provided by wireless sensor networks have garnered a great deal of attention from researchers and developers in recent years. Chirp spread spectrum (CSS) signaling formatting with time difference of arrival (TDOA) ranging technology is an effective LBS technique in regards to positioning accuracy, cost, and power consumption. The design and implementation of the location engine and location management based on TDOA location algorithms were the focus of this study; as the core of the system, the location engine was designed as a series of location algorithms and smoothing algorithms. To enhance the location accuracy, a Kalman filter algorithm and moving weighted average technique were respectively applied to smooth the TDOA range measurements and location results, which are calculated by the cooperation of a Kalman TDOA algorithm and a Taylor TDOA algorithm. The location management server, the information center of the system, was designed with Data Server and Mclient. To evaluate the performance of the location algorithms and the stability of the system software, we used a Nanotron nanoLOC Development Kit 3.0 to conduct indoor and outdoor location experiments. The results indicated that the location system runs stably with high accuracy at absolute error below 0.6 m.

  3. Experimental and analytical studies on the vibration serviceability of pre-stressed cable RC truss floor systems

    Science.gov (United States)

    Zhou, Xuhong; Cao, Liang; Chen, Y. Frank; Liu, Jiepeng; Li, Jiang

    2016-01-01

    The developed pre-stressed cable reinforced concrete truss (PCT) floor system is a relatively new floor structure, which can be applied to various long-span structures such as buildings, stadiums, and bridges. Due to the lighter mass and longer span, floor vibration would be a serviceability concern problem for such systems. In this paper, field testing and theoretical analysis for the PCT floor system were conducted. Specifically, heel-drop impact and walking tests were performed on the PCT floor system to capture the dynamic properties including natural frequencies, mode shapes, damping ratios, and acceleration response. The PCT floor system was found to be a low frequency (<10 Hz) and low damping (damping ratio<2 percent) structural system. The comparison of the experimental results with the AISC's limiting values indicates that the investigated PCT system exhibits satisfactory vibration perceptibility, however. The analytical solution obtained from the weighted residual method agrees well with the experimental results and thus validates the proposed analytical expression. Sensitivity studies using the analytical solution were also conducted to investigate the vibration performance of the PCT floor system.

  4. Development of Heat-resistant XLPE Cable and Accessories

    Science.gov (United States)

    Yamada, Hiroyuki; Nakagawa, Shinichi; Murata, Yoshinao; Kishi, Kouji; Katakai, Shoshi

    We have developed heat-resistant XLPE cable and accessories that can be operated at 105°C as the maximum permissible conductor temperature in normal operation. Through this cable system, greater transmission capacity can be achieved using existing cable ducts and without increasing the conductor size of the cable. We have developed heat-resistant XLPE insulation material which has a higher melting point than that of conventional XLPE. The breakdown strength of heat-resistant XLPE cable at 105°C is almost the same as that of conventional XLPE cable at 90°C. The heat deformation of the new cable at 105°C is almost the same as that of conventional XLPE cable at 90°C. Conventional self-pressurized rubber joints can be applied to heat-resistant cable lines with the new waterproof joint compound with low heat resistivity.

  5. Assessment of sodium conductor distribution cable

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The study assesses the barriers and incentives for using sodium conductor distribution cable. The assessment considers environmental, safety, energy conservation, electrical performance and economic factors. Along with all of these factors considered in the assessment, the sodium distribution cable system is compared to the present day alternative - an aluminum conductor system. (TFD)

  6. Damage Detection for Long-Span Cable-Stayed Bridge

    Institute of Scientific and Technical Information of China (English)

    Zhao Ling; Li Aiqun; Miao Changqing; Wang Yonglan

    2006-01-01

    Based on the updated finite-element model of a cable-stayed bridge, this study investigates the technique of identifying damage existing in cable or girder by means of numerical simulation. The modal analysis is performed to identify the changes in modal frequencies and curvatures caused by damage, and the static analysis is executed to detect the influence of damage on cable force. The results indicate a relatively significant decrease in frequencies of lower vertical bending modes due to the damage in cable and little change of frequencies due to damage in girder. Different sensitivities to the location of damaged cable are observed from the frequency changes of different bending modes, which can be used to initially locate the damaged cable. The damage in either cable or girder can be further localized by the most significant change in curvature of girder. The damage occurred in a cable produces a remarkable change in force of nearby cables, whereas the damage in girder brings little change of cable forces. In addition, a pragmatic approach for localizing the damage in girder or cable is proposed based on a comprehensive utilization of the changes in frequency of vertical bending modes, modal curvature of girder, and force in cables.

  7. Bayesian techniques to analyze and merge lightning locating system data

    Science.gov (United States)

    Bitzer, Phillip M.; Burchfield, Jeffrey C.

    2016-12-01

    As more lightning locating systems (LLSs) become available, there is a growing need to assess how each LLS performs and how to best merge data from multiple LLSs. A Bayesian analysis is used to compare the worldwide data of LLSs from three providers for November 2014 to October 2015: Earth Networks Total Lightning Network (ENTLN, Earth Networks), the combined data from the Global Lightning Detection 360 and National Lightning Detection Network (Vaisala), and the World Wide Lightning Location Network (WWLLN, University of Washington). By using the union of the data sets we are able to determine an estimate for the upper limit of the absolute detection efficiency of each system. Globally, ENTLN detected 56.8% of the discharges, the combined Vaisala networks detected 59.8%, and WWLLN detected 7.9%. In addition, there were 2.842 × 109 unique discharges detected by these LLSs, an average of 90.1 strokes/s.

  8. Design of the iLocater Acquisition Camera Demonstration System

    CERN Document Server

    Bechter, Andrew; Ketterer, Ryan; Crepp, Justin R; King, David; Zhao, Bo; Reynolds, Robert; Hinz, Philip; Brooks, Jack; Bechter, Eric

    2015-01-01

    Existing planet-finding spectrometers are limited by systematic errors that result from their seeing-limited design. Of particular concern is the use of multi-mode fibers (MMFs), which introduce modal noise and accept significant amounts of background radiation from the sky. We present the design of a single-mode fiber-based acquisition camera for a diffraction-limited spectrometer named "iLocater." By using the "extreme" adaptive optics (AO) system of the Large Binocular Telescope (LBT), iLocater will overcome the limitations that prevent Doppler instruments from reaching their full potential, allowing precise radial velocity (RV) measurements of terrestrial planets around nearby bright stars. The instrument presented in this paper, which we refer to as the acquisition camera "demonstration system," will measure on-sky single-mode fiber (SMF) coupling efficiency using one of the 8.4m primaries of the LBT in fall 2015.

  9. Enabling affordable and efficiently deployed location based smart home systems.

    Science.gov (United States)

    Kelly, Damian; McLoone, Sean; Dishongh, Terry

    2009-01-01

    With the obvious eldercare capabilities of smart environments it is a question of "when", rather than "if", these technologies will be routinely integrated into the design of future houses. In the meantime, health monitoring applications must be integrated into already complete home environments. However, there is significant effort involved in installing the hardware necessary to monitor the movements of an elder throughout an environment. Our work seeks to address the high infrastructure requirements of traditional location-based smart home systems by developing an extremely low infrastructure localisation technique. A study of the most efficient method of obtaining calibration data for an environment is conducted and different mobile devices are compared for localisation accuracy and cost trade-off. It is believed that these developments will contribute towards more efficiently deployed location-based smart home systems.

  10. Safer cables; Des cables plus surs

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2005-02-01

    Sixteen years after its adoption, the European construction products directive (CPD) will have soon a strong impact on the characteristics of electrical and communication cables used in European buildings and facilities. Among the six main requirements of this directive, the fire protection safety is a growing up concern and the electric cables have to be tested with respect to their fire resistance to become conformable with the directive. The cable industry has taken up the challenge. (J.S.)

  11. Nonlinear Analysis of Cable Vibration of a Multispan Cable-Stayed Bridge under Transverse Excitation

    Directory of Open Access Journals (Sweden)

    Kun Lin

    2014-01-01

    Full Text Available The nonlinear vibrations of cable in a multispan cable-stayed bridge subjected to transverse excitation are investigated. The MECS (multielements cable system model, where multielements per cable stay are used, is built up and used to analyze the model properties of the multispan cable-stayed bridges. Then, a simplified two-degrees-of-freedom (2-DOFs model, where the tower or the deck is reduced to a beam, is proposed to analyze the nonlinear dynamic behaviors of the beam and cable. The results of MECS model analysis show that the main tower in the multispan cable-stayed bridge is prone to the transverse vibration, and the local vibration of cables only has a little impact on the frequency values of the global modes. The results of simplified model analysis show that the energy can be transformed between the modes of the beam and cable when the nature frequencies of them are very close. On the other hand, with the transverse excitation changing, the cable can exhibit richer quasi-periodic or chaotic motions due to the nonlinear terms caused by the coupled mode between the beam and cable.

  12. Development of a Plug-and-Play Monitoring System for Cabled Observatories in the East China Sea

    Directory of Open Access Journals (Sweden)

    Yang Yu

    2015-07-01

    Full Text Available Seafloor observatories enable long term, continuous and multidisciplinary observations, promising major breakthroughs in marine environment research. The effort to remotely control in situ multidisciplinary equipment performing individual and cooperative tasks is both a challenge and a guarantee for the stable operations of functional observatories. With China starting to establish ocean observatory sensor networks, in this study we describe a monitoring system for cabled observatories in the East China Sea (ESOMS that enables this effort in a plug and play way. An information oriented monitoring architecture for ESOMS was first introduced, derived from a layered control model for ocean observatory sensor network. The architecture contained three components and enabled bidirectional information flow of observation data and commands, based on which architecture components were designed to enable plug-and-play control within related model layers. A control method enabled by general junction box (GJB and ocean sensor markup language (OSML was thus proposed as the plug-and-play solution for implementing ESOMS. The GJB-OSML enabled control method (GOE Control Method mainly actualized two processes, one of which was that the in situ GJB interfaced and represented every attached sensor as a Sensing Endpoint in the cabled observatory network. The other process was that the remote ESOMS utilized the same IP/Port related information modeled by OSML to create/operate a Function Node acted as agent of the in situ sensor. A case study for using ESOMS in the Xiaoqushan Seafloor Observatory was finally presented to prove its performance and applicability. Given this successful engineering trial, the ESOMS design and implementation could be applicable and beneficial for similar efforts in future construction of seafloor observatory network both at home and abroad.

  13. Nonlinear Finite Element Analysis of Ocean Cables

    Institute of Scientific and Technical Information of China (English)

    Nam-Il KIM; Sang-Soo JEON; Moon-Young KIM

    2004-01-01

    This study has focused on developing numerical procedures for the dynamic nonlinear analysis of cable structures subjected to wave forces and ground motions in the ocean. A geometrically nonlinear finite element procedure using the isoparametric curved cable element based on the Lagrangian formulation is briefly summarized. A simple and accurate method to determine the initial equilibrium state of cable systems associated with self-weights, buoyancy and the motion of end points is presented using the load incremental method combined with penalty method. Also the Newmark method is used for dynamic nonlinear analysis of ocean cables. Numerical examples are presented to validate the present numerical method.

  14. How do you like them cables?

    CERN Multimedia

    Sergei Malyukov

    Cabling work is not for clautrophobic people! Cables are like the blood vessels and nervous system of ATLAS. With the help of all these cables, we can power ATLAS, control the detector and read out the data. Like the human blood vessels, they penetrate inside the ATLAS volume, reaching each of its elements. The ATLAS developers started to think about design of services, cables and pipes at the very first stages of the project. The cabling project has been developing most intensively during the last five years, passing through the projection and CAD design phases, then the installation of cable trays and finally the cables. The cable installation itself took two and a half years and was done by teams of technicians from several institutes from Russia, the Czech Republic and Poland. Here are some numbers to illustrate the scale of the ATLAS cabling system. More than 25000 optical fiber channels are used for reading the information from the sub-detectors and delivering the timing signals. The total numbe...

  15. Energy losses of superconducting power transmission cables in the grid

    DEFF Research Database (Denmark)

    Østergaard, Jacob; Okholm, Jan; Lomholt, Karin

    2001-01-01

    One of the obvious motives for development of superconducting power transmission cables is reduction of transmission losses. Loss components in superconducting cables as well as in conventional cables have been examined. These losses are used for calculating the total energy losses of conventional...... as well as superconducting cables when they are placed in the electric power transmission network. It is concluded that high load connections are necessary to obtain energy saving by the use of HTSC cables. For selected high load connections, an energy saving of 40% is expected. It is shown...... that the thermal insulation and cooling machine efficiency are the most important loss element in a superconducting cable system...

  16. Online Cable Tester and Rerouter

    Science.gov (United States)

    Lewis, Mark; Medelius, Pedro

    2012-01-01

    Hardware and algorithms have been developed to transfer electrical power and data connectivity safely, efficiently, and automatically from an identified damaged/defective wire in a cable to an alternate wire path. The combination of online cable testing capabilities, along with intelligent signal rerouting algorithms, allows the user to overcome the inherent difficulty of maintaining system integrity and configuration control, while autonomously rerouting signals and functions without introducing new failure modes. The incorporation of this capability will increase the reliability of systems by ensuring system availability during operations.

  17. 46 CFR 113.10-3 - Cable runs.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs...

  18. Results of aircraft open-loop tests of an experimental magnetic leader cable system for guidance during roll-out and turnoff

    Science.gov (United States)

    Bundick, W. Thomas; Middleton, David B.; Poole, William L.

    1990-01-01

    An experimental magnetic leader cable (MLC) system designed to measure aircraft lateral displacement from centerline and heading relative to centerline during rollout, turnoff, and taxi was tested at NASA's Wallops Flight Facility using NASA's Transport System Research Vehicle (TSRV), a modified B-737. The MLC system consisted of ground equipment that produced a magnetic field about a wire along runway centerline and airborne equipment that detected the strength and direction of this field and computed displacement and heading. Results of these tests indicate that estimates of aircraft displacement from centerline produced by the magnetic leader cable system using either of the two algorithms appear to be adequate for use by an automatic control system during rollout, turnoff, and taxi. Estimates of heading, however, are not sufficiently accurate for use, probably because of distortion of the magnetic field by the metal aircraft.

  19. On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

  20. Stability improvement of a four cable-driven parallel manipulator using a center of mass balance system

    Science.gov (United States)

    Salafian, Iman; Stewart, Blake; Newman, Matthew; Zygielbaum, Arthur I.; Terry, Benjamin

    2017-04-01

    A four cable-driven parallel manipulator (CDPM), consisting of sophisticated spectrometers and imagers, is under development for use in acquiring phenotypic and environmental data over an acre-sized crop field. To obtain accurate and high quality data from the instruments, the end effector must be stable during sensing. One of the factors that reduces stability is the center of mass offset of the end effector, which can cause a pendulum effect or undesired tilt angle. The purpose of this work is to develop a system and method for balancing the center of mass of a 12th-scale CDPM to minimize vibration that can cause error in the acquired data. A simple method for balancing the end effector is needed to enable end users of the CDPM to arbitrarily add and remove sensors and imagers from the end effector as their experiments may require. A Center of Mass Balancing System (CMBS) is developed in this study which consists of an adjustable system of weights and a gimbal for tilt mitigation. An electronic circuit board including an orientation sensor, wireless data communication, and load cells was designed to validate the CMBS. To measure improvements gained by the CMBS, several static and dynamic experiments are carried out. In the experiments, the dynamic vibrations due to the translational motion and static orientation were measured with and without CMBS use. The results show that the CMBS system improves the stability of the end-effector by decreasing vibration and static tilt angle.

  1. Free vibrations of a taut cable with a general viscoelastic damper modeled by fractional derivatives

    Science.gov (United States)

    Sun, Limin; Chen, Lin

    2015-01-01

    This study extends dynamic understanding of a taut cable with a viscous damper at arbitrary location to that with a general linear viscoelastic (VE) damper portrayed by a five-parameter fractional derivative model (FDM). The FDM is able to describe a generalized relationship between force and deformation of viscoelastic dampers (material) in a wide frequency range, which can simulate a practical damper including its support condition or a secondary tie between neighboring cables. Free vibrations of the passively controlled cable system have then been formulated analytically through complex modal analysis. For the restricted case that the FDM is installed close to one cable anchorage, asymptotic solutions for the system complex frequency and modal damping are presented; explicit formulas have also been derived to determine the maximal attainable damping and corresponding optimum FDM parameters, based on which effects of frequency-dependent damper properties are appreciated. Considering the FDM located at arbitrary location, the three distinct regimes of frequency evolutions observed for a cable with a viscous damper have been generalized to that with a VE damper; also, new characteristics of the regime diagram and the frequency evolution in each regime are observed.

  2. 76 FR 32866 - Cable Landing Licenses; Correction

    Science.gov (United States)

    2011-06-07

    ... Systems Agency in the regulations that we published in the Federal Register of January 14, 2002, 67 FR... COMMISSION 47 CFR Part 1 Cable Landing Licenses; Correction AGENCY: Federal Communications Commission. ACTION... streamlined processing of cable landing license applications. Need for Correction As published, the...

  3. First Russian long length HTS power cable

    Science.gov (United States)

    Volkov, Eduard P.; Vysotsky, Vitaly S.; Firsov, Valery P.

    2012-11-01

    The Russian R&D Program for superconducting power devices is underway, supported both by government and electric power companies. In this program R&D on HTS power cables is considered as most advanced and close to commercialization. In the framework of the program, several, heavily instrumented, 5 m cables have been tested following by the 30 m - 3 phase experimental power cable development and testing in 2008-2009. The latest achievement is development and testing of the first long length 3 × 200 m power cable with rating 1.5/2 kA-20 kV. In parallel with just the cable development the innovative cryogenic system has been developed as well for the cable cooling. The system is using neon as working substance and radial turbo-machines in refrigerator. Cooling power is up to ∼8 kW at 65 K, inter-maintenance time ∼30,000 h. The cryogenic pump with superconducting motor can be used to provide subcooled liquid nitrogen flow ∼0.1-1.5 kg/s at 0.1-2.5 MPa pressure. After extensive tests at special test facility, HTS power cable and cryogenic system are planning to be installed at some substation in Moscow utility grid. In this review some details about Russian HTS power application program, 200 m cable and cryogenic system designs and tests results are presented.

  4. The Selling of Cable Television 1972.

    Science.gov (United States)

    National Cable Television Association, Inc., Washington, DC.

    The 1972 Cable Television Marketing Workshop reviewed in depth a wide variety of marketing and public relations techniques as they pertain to cable television. The workshop was attended by representatives of commercial television systems throughout the United States; it was intended to disseminate the sales and marketing experience of those…

  5. Colleges and Cable Franchising.

    Science.gov (United States)

    Glenn, Neal D.

    After noting issues of audience appeal and financial and philosophical support for educational broadcasting, this paper urges community colleges to play an active role in the process of cable franchising. The paper first describes a cable franchise as a contract between a government unit and the cable television (CATV) company which specifies what…

  6. Cable Supported Bridges

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    Cable supported bridges in the form of suspension bridges and cable-stayed bridges are distinguished by their ability to overcome large spans.The book concentrates on the synthesis of cable supported bridges, covering both design and construction aspects. The analytical part covers simple methods...

  7. Seamless Location Measuring System with Wifi Beacon Utilized and GPS Receiver based Systems in Both of Indoor and Outdoor Location Measurements

    OpenAIRE

    Kohei Arai

    2015-01-01

    A seamless location measuring system with WiFi beacon utilized and GPS receiver based systems in both of indoor and outdoor location measurements is proposed. Through the experiments in both of indoor and outdoor, it is found that location measurement accuracy is around 2-3 meters for the locations which are designated in both of indoor and outdoor.

  8. Equipment location in hospitals using RFID-based positioning system.

    Science.gov (United States)

    Shirehjini, Ali Asghar Nazari; Yassine, Abdulsalam; Shirmohammadi, Shervin

    2012-11-01

    Throughout various complex processes within hospitals, context-aware services and applications can help to improve the quality of care and reduce costs. For example, sensors and radio frequency identification (RFID) technologies for e-health have been deployed to improve the flow of material, equipment, personal, and patient. Bed tracking, patient monitoring, real-time logistic analysis, and critical equipment tracking are famous applications of real-time location systems (RTLS) in hospitals. In fact, existing case studies show that RTLS can improve service quality and safety, and optimize emergency management and time critical processes. In this paper, we propose a robust system for position and orientation determination of equipment. Our system utilizes passive (RFID) technology mounted on flooring plates and several peripherals for sensor data interpretation. The system is implemented and tested through extensive experiments. The results show that our system's average positioning and orientation measurement outperforms existing systems in terms of accuracy. The details of the system as well as the experimental results are presented in this paper.

  9. A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 1. Engineering Design and Instrumentation

    Directory of Open Access Journals (Sweden)

    M. Brad Eppard

    2011-05-01

    Full Text Available In 2001 the U.S. Army Corps of Engineers, Portland District (OR, USA, started developing the Juvenile Salmon Acoustic Telemetry System, a nonproprietary sensing technology, to meet the needs for monitoring the survival of juvenile salmonids through eight large hydroelectric facilities within the Federal Columbia River Power System (FCRPS. Initial development focused on coded acoustic microtransmitters and autonomous receivers that could be deployed in open reaches of the river for detection of the juvenile salmonids implanted with microtransmitters as they passed the autonomous receiver arrays. In 2006, the Pacific Northwest National Laboratory began the development of an acoustic receiver system for deployment at hydropower facilities (cabled receiver for detecting fish tagged with microtransmitters as well as tracking them in two or three dimensions for determining route of passage and behavior as the fish passed at the facility. The additional information on route of passage, combined with survival estimates, is used by the dam operators and managers to make structural and operational changes at the hydropower facilities to improve survival of fish as they pass the facilities through the FCRPS.

  10. A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation

    Directory of Open Access Journals (Sweden)

    Grapow Martin TR

    2012-06-01

    Full Text Available Abstract Background Wire closure still remains the preferred technique despite reasonable disadvantages. Associated complications, such as infection and sternal instability, cause time- and cost-consuming therapies. We present a new tool for sternal closure with its first clinical experience and results. Methods The sternal ZipFixTM System is based on the cable-tie principle. It primarily consists of biocompatible Poly-Ether-Ether-Ketone implants and is predominantly used peristernally through the intercostal space. The system provides a large implant-to-bone contact for better force distribution and for avoiding bone cut through. Results 50 patients were closed with the ZipFixTM system. No sternal instability was observed at 30 days. Two patients developed a mediastinitis that necessitated the removal of the device; however, the ZipFixTM were intact and the sternum remained stable. Conclusions In our initial evaluation, the short-term results have shown that the sternal ZipFixTM can be used safely and effectively. It is fast, easy to use and serves as a potential alternative for traditional wire closure.

  11. Optimal Energy Harvesting from Vortex-Induced Vibrations of Cables

    CERN Document Server

    Antoine, G O; Michelin, S

    2016-01-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy toward this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with ...

  12. Lattice Based Mix Network for Location Privacy in Mobile System

    Directory of Open Access Journals (Sweden)

    Kunwar Singh

    2015-01-01

    Full Text Available In 1981, David Chaum proposed a cryptographic primitive for privacy called mix network (Mixnet. A mixnet is cryptographic construction that establishes anonymous communication channel through a set of servers. In 2004, Golle et al. proposed a new cryptographic primitive called universal reencryption which takes the input as encrypted messages under the public key of the recipients not the public key of the universal mixnet. In Eurocrypt 2010, Gentry, Halevi, and Vaikunthanathan presented a cryptosystem which is an additive homomorphic and a multiplicative homomorphic for only one multiplication. In MIST 2013, Singh et al. presented a lattice based universal reencryption scheme under learning with error (LWE assumption. In this paper, we have improved Singh et al.’s scheme using Fairbrother’s idea. LWE is a lattice hard problem for which till now there is no polynomial time quantum algorithm. Wiangsripanawan et al. proposed a protocol for location privacy in mobile system using universal reencryption whose security is reducible to Decision Diffie-Hellman assumption. Once quantum computer becomes a reality, universal reencryption can be broken in polynomial time by Shor’s algorithm. In postquantum cryptography, our scheme can replace universal reencryption scheme used in Wiangsripanawan et al. scheme for location privacy in mobile system.

  13. Recommender systems for location-based social networks

    CERN Document Server

    Symeonidis, Panagiotis; Manolopoulos, Yannis

    2014-01-01

    Online social networks collect information from users' social contacts and their daily interactions (co-tagging of photos, co-rating of products etc.) to provide them with recommendations of new products or friends. Lately, technological progressions in mobile devices (i.e. smart phones) enabled the incorporation of geo-location data in the traditional web-based online social networks, bringing the new era of Social and Mobile Web. The goal of this book is to bring together important research in a new family of recommender systems aimed at serving Location-based Social Networks (LBSNs). The chapters introduce a wide variety of recent approaches, from the most basic to the state-of-the-art, for providing recommendations in LBSNs. The book is organized into three parts. Part 1 provides introductory material on recommender systems, online social networks and LBSNs. Part 2 presents a wide variety of recommendation algorithms, ranging from basic to cutting edge, as well as a comparison of the characteristics of t...

  14. Forced vibration of a ball attached to a cable

    Directory of Open Access Journals (Sweden)

    Douglas Oliver

    2000-01-01

    Full Text Available This work describes an analytic solution to predict the forced oscillation of a suspended cable and an attached ball. The oscillations are driven by a sinusoidal movement at the fixed end of the cable. This problem may be used in the verification of numerical software which is commonly used to design systems with suspended cables.

  15. Results from the Danish high temperature superconducting power cable project

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob

    2002-01-01

    For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying approxim...

  16. Regulation of Cable Television by the State of New York.

    Science.gov (United States)

    Jones, William K.

    In order to determine the appropriate role for the State of New York in relation to cable television, a comprehensive report was prepared for the state Public Service Commission by one of its members. In addition to background detail on the technology and potential of cable television, the report investigates current cable systems and current…

  17. 46 CFR 111.60-6 - Fiber optic cable.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fiber optic cable. 111.60-6 Section 111.60-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-6 Fiber optic cable. Each fiber optic cable must— (a)...

  18. 14 CFR 23.1365 - Electric cables and equipment.

    Science.gov (United States)

    2010-01-01

    ...) Electrical cables must be installed such that the risk of mechanical damage and/or damage cased by fluids... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electric cables and equipment. 23.1365... Electrical Systems and Equipment § 23.1365 Electric cables and equipment. (a) Each electric connecting...

  19. Comparison of Tension-Band Wiring With the Cable Pin System in Patella Fractures: A Randomized Prospective Study.

    Science.gov (United States)

    Tian, Qing-xian; Hai, Yong; Du, Xin-ru; Xu, Zi-yu; Lu, Tie; Shan, Lei; Liu, Yang; Zhou, Jun-lin

    2015-12-01

    To compare the outcome of tension-band wiring (TBW) with the cable pin system (CPS) for transverse fractures of the patella. Randomized prospective study. Academic Level I trauma center. From February 2008 to December 2011, 73 consecutive patients with transverse fractures of the patella were prospectively enrolled in this study. The patients were randomly divided into 2 groups: one group was treated using the CPS, and the other group was treated using the modified TBW. The clinical outcome assessment included analyses of the radiographic images, the modified Hospital for Special Surgery scoring system, and complications. The follow-up time ranged from 12 to 29 months. All fractures healed, with a union rate of 100%. The fracture healing time was significantly shorter in the CPS group (8.51 ± 2.59 weeks, n = 34) compared with the TBW group (11.79 ± 3.04 weeks, n = 39). Postoperative complications in the CPS and TBW groups were observed in 1 and 9 patients, respectively, a difference that was statistically significant. The mean Hospital for Special Surgery score for the CPS group (90.53 ± 5.19 points) was significantly higher than that for the TBW group (81.36 ± 12.71 points). The CPS is a viable option for transverse fractures of the patella and is associated with a shorter healing time, fewer complications, and better function than TBW. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  20. 4D measurement system for automatic location of anatomical structures

    Science.gov (United States)

    Witkowski, Marcin; Sitnik, Robert; Kujawińska, Małgorzata; Rapp, Walter; Kowalski, Marcin; Haex, Bart; Mooshake, Sven

    2006-04-01

    Orthopedics and neurosciences are fields of medicine where the analysis of objective movement parameters is extremely important for clinical diagnosis. Moreover, as there are significant differences between static and dynamic parameters, there is a strong need of analyzing the anatomical structures under functional conditions. In clinical gait analysis the benefits of kinematical methods are undoubted. In this paper we present a 4D (3D + time) measurement system capable of automatic location of selected anatomical structures by locating and tracing the structures' position and orientation in time. The presented system is designed to help a general practitioner in diagnosing selected lower limbs' dysfunctions (e.g. knee injuries) and also determine if a patient should be directed for further examination (e.g. x-ray or MRI). The measurement system components are hardware and software. For the hardware part we adapt the laser triangulation method. In this way we can evaluate functional and dynamic movements in a contact-free, non-invasive way, without the use of potentially harmful radiation. Furthermore, opposite to marker-based video-tracking systems, no preparation time is required. The software part consists of a data acquisition module, an image processing and point clouds (point cloud, set of points described by coordinates (x, y, z)) calculation module, a preliminary processing module, a feature-searching module and an external biomechanical module. The paper briefly presents the modules mentioned above with the focus on the feature-searching module. Also we present some measurement and analysis results. These include: parameters maps, landmarks trajectories in time sequence and animation of a simplified model of lower limbs.

  1. 基于Wi-Fi物联网技术的电缆隧道安全管理系统%Cable Tunnel Safety Management System Based on Wi-Fi IOT Technology

    Institute of Scientific and Technical Information of China (English)

    吕海晶

    2013-01-01

    In view of the ubiquitous hidden dangers existed in cable tunnel, such as, unknowing personnel-location is not known, communication blind district, poor environment and low oxygen content, the cable tunnel safety management system was developed by advanced Wi-Fi internet of things technology, realizing accurate personnel position, voice scheduling, video surveillance and online environment monitoring. The system has good compatibility, offers a platform shared by multi-modules. The whole scheme is feasible and economic.%针对电缆隧道普遍存在的隧道内人员位置不可知、通信存在盲区、环境恶劣、含氧量低等安全隐患,采用先进的Wi-Fi物联网技术,开发了电缆隧道安全管理系统,实现人员的精准定位、语音调度、视频监控以及隧道内环境在线监测等功能,多个模块共用一套平台,系统具有很好的兼容性,经济运行比高。

  2. Locomotor training through a 3D cable-driven robotic system for walking function in children with cerebral palsy: a pilot study.

    Science.gov (United States)

    Wu, Ming; Kim, Janis; Arora, Pooja; Gaebler-Spira, Deborah J; Zhang, Yunhui

    2014-01-01

    Locomotor training using treadmill has been shown to elicit significant improvements in locomotor ability for some children with cerebral palsy (CP), the functional gains are relatively small and it requires greater involvement from a physical therapist. Current robotic gait training systems are effective in reducing the strenuous work of a physical therapist during locomotor training, but are less effective in improving locomotor function in some children with CP due to the limitations of the systems. Thus, a 3D cable-driven robotic gait training system was developed and tested in five children with CP through a 6 week of long-term gait training. Results indicated that both overground walking speed and 6 minute walking distance improved after robot assisted treadmill training through the cable-driven robotic system, and partially retained at 8 weeks after the end of training. Results from this pilot study indicated that it seems feasible to conduct locomotor training in children with CP through the 3D cable-driven robotic system.

  3. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges

    Institute of Scientific and Technical Information of China (English)

    孙炳楠; 汪至刚; 高赞明; 倪一清

    2003-01-01

    This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced.

  4. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges"

    Institute of Scientific and Technical Information of China (English)

    孙炳楠; 汪至刚; 高赞明; 倪一清

    2003-01-01

    This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced.

  5. 振荡电压下电缆典型缺陷局部放电的统计特征及定位研究%Statistical Characteristic and Location of Partial Discharge Caused by Typical Defects in Power Cable Under Damped Oscillation Voltage

    Institute of Scientific and Technical Information of China (English)

    常文治; 葛振东; 时翔; 马国明; 陈志勇; 崔潇; 李成榕; 陈雪薇; 唐志国

    2013-01-01

    Oscillating wave test system (OWTS) possesses such advantages as calibratable detection results,not causing deterioration in power cable insulation,especially suitable to field testing and so on while it is utilized to detect partial discharge (PD) occurred at the position of power cable,where defects exist,under damped oscillation voltage.To research statistical characteristic of PD caused by power cable defects under damped oscillation voltage,four circumstances are preset to simulate four typical cable defects,they are:A) incorrect winding-up of insulation adhesive tape at intermediate joint core,B) a nadel at the surface of conductor core pricking into insulation layer of cable,C) breakage of outer semiconducting layer of cable body and D) a extrinsic metal pin pricking into main insulation layer of cable but not touching with both surfaces of conductor core and inner semiconducting layer.Using self-developed OWTS,the PD signals caused by preset circumstances are measured,and then the phasic statisticalcircumstances are measured,and then the phasic statistical characteristics of PD caused by the four circumstances with different severities are analyzed by the phase analysis of oscillation voltage.Analysis results show that all location errors of the four preset circumstances do not exceed 10cm.The PD signals caused by circumstance A concentrate within two phase intervals of oscillation voltage from 20° to 70° and from 200° to 280° respectively and the densest distribution appears nearby 230°,and in grey image they sparsely distribute in triangle shape,and the discharge density in the negative half-cycle is slightly denser than in positive half-cycle; the PD signals caused by circumstance B concentrate within two phase intervals of oscillation voltage from 20° to 110° and from 200° to 280° respectively and in grey image they symmetrically distribute in rectangular shape,and the distribution densities in positive and negative half-cycle are basically

  6. Umbilical Cable Recovery Load Analysis

    Institute of Scientific and Technical Information of China (English)

    YAN Shu-wang; JIA Zhao-lin; FENG Xiao-wei; LI Shi-tao

    2013-01-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field.The severe ocean environment makes great challenges to umbilical maintenance and repair work.Damaged umbilical is usually recovered for the regular operation of the offshore production system.Analysis on cables in essence is a two-point boundary problem.The tension load at the mudline must be known first,and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation.The recovery analysis also involves umbilicalsoil interaction and becomes more complicated.Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed.The analysis results provide a theoretical reference for offshore on-deck operation.

  7. Umbilical cable recovery load analysis

    Science.gov (United States)

    Yan, Shu-wang; Jia, Zhao-lin; Feng, Xiao-wei; Li, Shi-tao

    2013-06-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field. The severe ocean environment makes great challenges to umbilical maintenance and repair work. Damaged umbilical is usually recovered for the regular operation of the offshore production system. Analysis on cables in essence is a two-point boundary problem. The tension load at the mudline must be known first, and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation. The recovery analysis also involves umbilical-soil interaction and becomes more complicated. Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed. The analysis results provide a theoretical reference for offshore on-deck operation.

  8. Collection System Cable Routing and Wake Losses Optimization in Offshore Wind Farms

    NARCIS (Netherlands)

    Fragoso Rodrigues, S.M.; Bauer, P.; Bosman, P.A.N.; Pierik, J.

    2014-01-01

    Offshore wind farms with high installed capacities and located further from the shore are starting to be built by northern European countries. Furthermore, it is expected that by 2020, several dozens of large offshore wind farms will be built in the Baltic, Irish and North seas. These wind farms wil

  9. On-line Monitoring System of Circulating Current of XLPE Cables%XLPE电缆金属护套环流在线监测系统

    Institute of Scientific and Technical Information of China (English)

    喻世根; 张亮; 李锰; 吴畏

    2011-01-01

    XLPE cable has been widely applied in the grid because of its good electrical properties. Its insulation state directly relates to the safe and reliable operation of power system, how to effectively monitor the insulation state of XLPE cables is very important for power system. In order to meet the needs of power system, XLPE cables metal sheath circulation current on-line monitoring system is designed based on LabVIEW and described the hardware and software designed methods in this paper.%XLPE电缆由于其良好的电气性能在电网中得到了广泛地应用,XLPE电缆的绝缘状况直接影响到电力系统的安全和稳定,如何有效地监测XLPE电缆的绝缘状态对电力系统的安全稳定运行意义重大.为了满足电力系统的需要,有效地监测电缆绝缘状况,以LabVIEW图形可视化编程软件作为开发工具,设计了XLPE电缆金属护套环流在线监测系统,以此监测电缆的绝缘状况,文中阐述了监测系统的硬件组成和软件设计方法.

  10. Effects of fundamental factors on coupled vibration of wind-rail vehicle-bridge system for long-span cable-stayed bridge

    Institute of Scientific and Technical Information of China (English)

    张明金; 李永乐; 汪斌

    2016-01-01

    In a wind-vehicle-bridge (WVB) system, there are various interactions among wind, vehicle and bridge. The mechanism for coupling vibration of wind-vehicle-bridge systems is explored to demonstrate the effects of fundamental factors, such as mean wind, fluctuating wind, buffeting, rail irregularities, light rail vehicle vibration and bridge stiffness. A long cable-stayed bridge which carries light rail traffic is regarded as a numerical example. Firstly, a finite element model is built for the long cable-stayed bridge. The deck can generally be idealized as three-dimensional spine beam while cables are modeled as truss elements. Vehicles are modeled as mass-spring-damper systems. Rail irregularities and wind fluctuation are simulated in time domain by spectrum representation method. Then, aerodynamic loads on vehicle and bridge deck are measured by section model wind tunnel tests. Eight vertical and torsional flutter derivatives of bridge deck are identified by weighting ensemble least-square method. Finally, dynamic responses of the WVB system are analyzed in a series of cases. The results show that the accelerations of the vehicle are excited by the fluctuating wind and the track irregularity to a great extent. The transverse forces of wheel axles mainly depend on the track irregularity. The displacements of the bridge are predominantly determined by the mean wind and restricted by its stiffness. And the accelerations of the bridge are enlarged after adding the fluctuating wind.

  11. Location and acquisition of objects in unpredictable locations. [a teleoperator system with a computer for manipulator control

    Science.gov (United States)

    Sword, A. J.; Park, W. T.

    1975-01-01

    A teleoperator system with a computer for manipulator control to combine the capabilities of both man and computer to accomplish a task is described. This system allows objects in unpredictable locations to be successfully located and acquired. By using a method of characterizing the work-space together with man's ability to plan a strategy and coarsely locate an object, the computer is provided with enough information to complete the tedious part of the task. In addition, the use of voice control is shown to be a useful component of the man/machine interface.

  12. A Multiscale Finite Element Model Validation Method of Composite Cable-Stayed Bridge Based on Structural Health Monitoring System

    Directory of Open Access Journals (Sweden)

    Rumian Zhong

    2015-01-01

    Full Text Available A two-step response surface method for multiscale finite element model (FEM updating and validation is presented with respect to Guanhe Bridge, a composite cable-stayed bridge in the National Highway number G15, in China. Firstly, the state equations of both multiscale and single-scale FEM are established based on the basic equation in structural dynamic mechanics to update the multiscale coupling parameters and structural parameters. Secondly, based on the measured data from the structural health monitoring (SHM system, a Monte Carlo simulation is employed to analyze the uncertainty quantification and transmission, where the uncertainties of the multiscale FEM and measured data were considered. The results indicate that the relative errors between the calculated and measured frequencies are less than 2%, and the overlap ratio indexes of each modal frequency are larger than 80% without the average absolute value of relative errors. These demonstrate that the proposed method can be applied to validate the multiscale FEM, and the validated FEM can reflect the current conditions of the real bridge; thus it can be used as the basis for bridge health monitoring, damage prognosis (DP, and safety prognosis (SP.

  13. Power systems locational marginal pricing in deregulated markets

    Science.gov (United States)

    Wang, Hui-Fung Francis

    Since the beginning of the 1990s, the electricity business is transforming from a vertical integrating business to a competitive market operations. The generation, transmission, distribution subsystem of an electricity utility are operated independently as Genco (generation subsystem), Transco (transmission subsystem), and Distco (distribution subsystem). This trend promotes more economical inter- and intra regional transactions to be made by the participating companies and the users of electricity to achieve the intended objectives of deregulation. There are various types of electricity markets that are implemented in the North America in the past few years. However, transmission congestion management becomes a key issue in the electricity market design as more bilateral transactions are traded across long distances competing for scarce transmission resources. It directly alters the traditional concept of energy pricing and impacts the bottom line, revenue and cost of electricity, of both suppliers and buyers. In this research, transmission congestion problem in a deregulated market environment is elucidated by implementing by the Locational Marginal Pricing (LMP) method. With a comprehensive understanding of the LMP method, new mathematical tools will aid electric utilities in exploring new business opportunities are developed and presented in this dissertation. The dissertation focuses on the development of concept of (LMP) forecasting and its implication to the market participants in deregulated market. Specifically, we explore methods of developing fast LMP calculation techniques that are differ from existing LMPs. We also explore and document the usefulness of the proposed LMP in determining electricity pricing of a large scale power system. The developed mathematical tools use of well-known optimization techniques such as linear programming that are support by several flow charts. The fast and practical security constrained unit commitment methods are the

  14. Location Sharing System Using GPS Technology for Minimizing SMS Delivery

    Directory of Open Access Journals (Sweden)

    C.Manikandan

    2016-05-01

    Full Text Available Enhanced Privacy in Mobile Online Social Networks to providing the location information to the User /server in the online location server. MOSNs, more and more users‘ location information will be collected by the service providers in mOSN. The users‘ privacy, including location privacy and social network privacy can be improved using the User Registration & encryption of the data stored into the server. It should aiming at achieving enhanced privacy against the insider attack launched by the service providers in mOSNs, we introduce a new architecture with multiple location servers for the first time and propose a secure solution supporting location sharing among friends and strangers in location-based applications. In our construction, the user‘s friend set in each friend‘s query submitted to the location servers is divided into multiple subsets by the social network server randomly. Location-based services (LBSs are one of the most important components in mOSNs, which provides information and entertainment service based on the geographical position of the mobile device. The entity of users, with mobile devices, is able to communicate with other users and share their locations. Online social network Server manages users‘ identity-related information such as users‘ profiles and friend lists. Location server stores users‘ location information and provides LBSs according to the requests sent from users. Here we are going to improve the user location privacy, social network privacy.

  15. 港口集装箱吊具电缆随动系统改造%Improvement on Cable Servo-system for Container Spreader in Harbor

    Institute of Scientific and Technical Information of China (English)

    颜全生; 丘俊

    2011-01-01

    Most cable servo-systems for container spreaders in harbors are unreliable, which makes cables slide out of cable brackets frequently and affects the perfomaance of spreaders. In this paper, the automatic control system is improved by PLC, VLT5022 frequency converter of Danfoss, which proves that the rate of accidents is on the decrease and operating efficiency is improved greatly after using this new control system.%针对港口集装箱岸桥吊具的电缆因岸桥吊随动系统不太可靠,使电缆频繁跑出电缆筐,直接影响岸桥吊作业的现状,使用PLC和丹佛斯VLT5022变频器组成的自动控制系统对其进行改造,较好地优化了港口集装箱岸桥吊具系统功能,提高了作业效率.

  16. Power applications for superconducting cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Hansen, Steen; Jørgensen, Preben

    2000-01-01

    High temperature superconducting (HTS) cables for use in electric ac power systems are under development around the world today. There are two main constructions under development: the room temperature dielectric design and the cryogenic dielectric design. However, theoretical studies have shown...

  17. Cable Television: Developing Community Services.

    Science.gov (United States)

    Carpenter-Huffman, Polly; And Others

    The final volume of a four-volume study focuses on community use of cable television systems. Four separate aspects are discussed extensively: the possibilities of public access, use in municipal service applications, uses in education, and a guide for education planners. Each section contains several appendixes and the education sections include…

  18. Superconducting power cables in Denmark - a case study

    DEFF Research Database (Denmark)

    Østergaard, Jacob

    1997-01-01

    A case study of a 450 MVA, 132 kV high temperature superconducting (HTS) power transmission cable has been carried out. In the study, a superconducting cable system is compared to a conventional cable system which is under construction for an actual transmission line in the Danish grid. The study...... that HTS cables will be less expensive for high power ratings, have lower losses for lines with a high load, and have a reduced reactive power production. The use of superconducting cables in Denmark accommodate plans by the Danish utility to make a substantial conversion of overhead lines to underground...

  19. Cable Television for Librarians. Cable Television Primer

    Science.gov (United States)

    Briscoe, Wallace C.

    1973-01-01

    The development of cable television, its present state, and future prospects, including a possible role for libraries, are discussed. (Other conference materials are LI 503071 and 503073 through 503084.) (SJ)

  20. HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV

    Directory of Open Access Journals (Sweden)

    T.Yu. Antonets

    2015-12-01

    Full Text Available In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables. Tests to heat of cables for XLPE-polyethylene are used as a solid dielectric insulation. The line to XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. When single-core cables are installed in parallel the load current may not share equally between the parallel cables. This is because a significant proportion of the impedance of large conductors is due to self reactance and mutual reactance. Hence the spacing and relative location of each cable will have an effect on the current sharing. Calculation for each cable configuration is necessary. Possibility of using for determining the thermal properties of XLPE-cables a sheath applied over the cable surface with coefficient convection heat transfer between cable surface and the air region about it of equal zero. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

  1. Deck and Cable Dynamic Testing of a Single-span Bridge Using Radar Interferometry and Videometry Measurements

    Science.gov (United States)

    Piniotis, George; Gikas, Vassilis; Mpimis, Thanassis; Perakis, Harris

    2016-03-01

    This paper presents the dynamic testing of a roadway, single-span, cable-stayed bridge for a sequence of static load and ambient vibration monitoring scenarios. Deck movements were captured along both sideways of the bridge using a Digital Image Correlation (DIC) and a Ground-based Microwave Interfererometer (GBMI) system. Cable vibrations were measured at a single point location on each of the six cables using the GBMI technique. Dynamic testing involves three types of analyses; firstly, vibration analysis and modal parameter estimation (i. e., natural frequencies and modal shapes) of the deck using the combined DIC and GBMI measurements. Secondly, dynamic testing of the cables is performed through vibration analysis and experimental computation of their tension forces. Thirdly, the mechanism of cable-deck dynamic interaction is studied through their Power Spectra Density (PSD) and the Short Time Fourier Transform (STFT) analyses. Thereby, the global (deck and cable) and local (either deck or cable) bridge modes are identified, serving a concrete benchmark of the current state of the bridge for studying the evolution of its structural performance in the future. The level of synergy and complementarity between the GBMI and DIC techniques for bridge monitoring is also examined and assessed.

  2. Location, location, location

    NARCIS (Netherlands)

    Anderson, S.P.; Goeree, J.K.; Ramer, R.

    1997-01-01

    We analyze the canonical location-then-price duopoly game with general log- concave consumer densities. A unique pure-strategy equilibrium to the two-stage game exists if the density is not "too asymmetric" and not "too concave." These criteria are satisfied by many commonly used densities. Equilibr

  3. Operation experiences with a 30 kV/100 MVA high temperature superconducting cable system

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Däumling, Manfred; Jensen, Kim Høj;

    2004-01-01

    of 1157 A. The operation experiences include over-currents of 6 kA due to faults on peripheral lines, commissioning, servicing and failure responses on the cooling system, continuous 24 h, 7 day per week monitoring and performance of the alarm system. The implications of these experiences for the future...

  4. Current Status of Cable Television in the Top-100 Broadcast Markets.

    Science.gov (United States)

    Kaplan, Stuart J.

    1978-01-01

    A study of the status of cable television in the major broadcast markets suggests that the cable industry has made very little progress in penetrating the top-100 markets, that the rate of development of new cable systems in the top-100 markets has slowed in recent years, and that the primary function of cable television is to retransmit…

  5. The Cable Television Industry's Ongoing Commitment to Education and America's Teachers, Children and Families.

    Science.gov (United States)

    National Cable Television Association, Inc., Washington, DC.

    This cable television industry report provides a sampling of case studies and overviews which describe cable operator, multiple system operator (MSO), and program networks' initiatives, resources, and support for education and the communities they serve. The information focuses on the following categories: Cable in the Classroom; cable's high…

  6. 现代架空线输电系统中的高压电缆段%Aspects of High Voltage Cable Sections in Modern Overhead Line Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Electrical power transmission is dominated by overhead line systems at present. This is mainly based on more than hundred years of experience of utilities in running overhead lines. Furthermore, overhead lines have proven their operational reliability and functional assurance. In the past, cables were used in distribution networks in urban areas for the most part with the exception of direct current submarine cables. New developments of high voltage XLPE cables make it possible to use this technology for EHV level applications in transmission networks. Within this paper, mixed network configurations, consisting of overhead lines and high voltage cables, are investigated. An exemplary EHV transmission line with a total length of about 100 km, which is quite typical for Central Europe, has been studied. Several different line combinations are discussed with varied rates between overhead line sections and cable sections length in practice. The length of the cable sections are ranging from several kilometers up to lengths of 100 km. In this paper the work focuses on the transient behavior of combined 400 kV overhead and cable lines during switching processes and lightning impacts. A number of calculations were carried out to get an overview of the transient stress in numerous network nodes along the transmission system. Numerical programs like ATP/EMTP have been used for these simulations. Peak values and wave shapes of the transient voltage stress have been evaluated, based on different systems and within possible combinations. In respect of the insulation coordination and transient stress at network nodes, the voltage-time trends are also analyzed. The combination of high voltage overhead and cable transmission systems, especially such with lengths of more than about 50 km, are making tightened and extended demands to the network design, to the operational management and of course to the network protection also. As an output of this investigations, the results might

  7. 3D beam shape estimation based on distributed coaxial cable interferometric sensor

    Science.gov (United States)

    Cheng, Baokai; Zhu, Wenge; Liu, Jie; Yuan, Lei; Xiao, Hai

    2017-03-01

    We present a coaxial cable interferometer based distributed sensing system for 3D beam shape estimation. By making a series of reflectors on a coaxial cable, multiple Fabry–Perot cavities are created on it. Two cables are mounted on the beam at proper locations, and a vector network analyzer (VNA) is connected to them to obtain the complex reflection signal, which is used to calculate the strain distribution of the beam in horizontal and vertical planes. With 6 GHz swept bandwidth on the VNA, the spatial resolution for distributed strain measurement is 0.1 m, and the sensitivity is 3.768 MHz mε ‑1 at the interferogram dip near 3.3 GHz. Using displacement-strain transformation, the shape of the beam is reconstructed. With only two modified cables and a VNA, this system is easy to implement and manage. Comparing to optical fiber based sensor systems, the coaxial cable sensors have the advantage of large strain and robustness, making this system suitable for structure health monitoring applications.

  8. Development of Compact Seafloor Cabled Seismic and Tsunami Observation System Using ICT and Installation Plan to Off-Sanriku Region, Japan

    Science.gov (United States)

    Shinohara, M.; Yamada, T.; Sakai, S.; Shiobara, H.; Kanazawa, T.

    2014-12-01

    A seismic and tsunami observation system using seafloor optical fiber had been installed off Sanriku, northeastern Japan in 1996. The objectives of the system are to obtain exact seismic activity related to plate subduction and to observe tsunami on seafloor. The continuous real-time observation has been carried out since the installation. In March 2011, the Tohoku earthquake occurred at the plate boundary near the Japan Trench, and the system recorded seismic waves and tsunamis by the mainshock. These data are useful to obtain accurate position of the source faults and source region of tsunami generated by the event. However, the landing station of the system was damaged by huge tsunami, and the observation was suspended. Because the real-time seafloor observation by cabled system is important in this region, we decide to reconstruct a landing station and install newly developed Ocean Bottom Cabled Seismic and Tsunami (OBCST) observation system for additional observation and/or replacement of the existing system. From 2005, we have been developed the new compact Ocean Bottom Cabled Seismometer (OBCS) system using Information and Communication Technology (ICT). Our system is characterized by securement of reliability by using TCP/IP technology and down-sizing of an observation node using up-to-date electronics technology. In 2010, the first OBCS was installed near Awashima-island in the Japan Sea, and is being operated continuously. The new OBCST system is placed as the second generation of our system, and has two types of observation nodes. Both types have accelerometers as seismic sensors. One type of observation nodes equips a crystal oscillator type pressure gauge as tsunami sensor. Another type has an external port for additional observation sensor by using Power over Ethernet technology. Clocks in observation nodes can be synchronized through TCP/IP protocol with an accuracy of 300 ns (IEEE 1588). A simple canister for tele-communication seafloor cable is

  9. Analytical Solution for the Current Distribution in Multistrand Superconducting Cables

    CERN Document Server

    Bottura, L; Fabbri, M G

    2002-01-01

    Current distribution in multistrand superconducting cables can be a major concern for stability in superconducting magnets and for field quality in particle accelerator magnets. In this paper we describe multistrand superconducting cables by means of a distributed parameters circuit model. We derive a system of partial differential equations governing current distribution in the cable and we give the analytical solution of the general system. We then specialize the general solution to the particular case of uniform cable properties. In the particular case of a two-strand cable, we show that the analytical solution presented here is identical to the one already available in the literature. For a cable made of N equal strands we give a closed form solution that to our knowledge was never presented before. We finally validate the analytical solution by comparison to numerical results in the case of a step-like spatial distribution of the magnetic field over a short Rutherford cable, both in transient and steady ...

  10. Location-Based Resource Allocation for OFDMA Cognitive Radio Systems

    KAUST Repository

    Ghorbel, Mahdi

    2011-05-01

    Cognitive radio is one of the hot topics for emerging and future wireless communication. It has been proposed as a suitable solution for the spectrum scarcity caused by the increase in frequency demand. The concept is based on allowing unlicensed users, called cognitive or secondary users, to share the unoccupied frequency bands with their owners, called the primary users, under constraints on the interference they cause to them. In order to estimate this interference, the cognitive system usually uses the channel state information to the primary user, which is often impractical to obtain. However, we propose to use location information, which is easier to obtain, to estimate this interference. The purpose of this work is to propose a subchannel and power allocation method which maximizes the secondary users\\' total capacity under the constraints of limited budget power and total interference to the primary under certain threshold. We model the problem as a constrained optimization problem for both downlink and uplink cases. Then, we propose low-complexity resource allocation schemes based on the waterfilling algorithm. The simulation results show the efficiency of the proposed method with comparison to the exhaustive search algorithm.

  11. Airborne system for detection and location of radio interference sources

    Science.gov (United States)

    Audone, Bruno; Pastore, Alberto

    1992-11-01

    The rapid expansion of telecommunication has practically saturated every band of Radio Frequency Spectrum; a similar expansion of electrical and electronic devices has affected all radio communications which are, in some way, influenced by a large amount of interferences, either intentionally or unintentionally produced. Operational consequences of these interferences, particularly in the frequency channels used for aeronautical services, can be extremely dangerous, making mandatory a tight control of Electromagnetic Spectrum. The present paper analyzes the requirements and the problems related to the surveillance, for civil application, of the Electromagnetic Spectrum between 20 and 1000 MHz, with particular attention to the detection and location of radio interference sources; after a brief introduction and the indication of the advantages of an airborne versus ground installation, the airborne system designed by Alenia in cooperation with Italian Ministry of Post and Telecommunication, its practical implementation and the prototype installation on board of a small twin turboprop aircraft for experimentation purposes is presented. The results of the flight tests are also analyzed and discussed.

  12. Practical Applications of Cables and Ropes in the ISS Countermeasures System

    Science.gov (United States)

    Svetlik, Randall G.; Moore, Cherice; Williams, Antony

    2017-01-01

    National Aeronautics and Space Administration (NASA) uses exercise countermeasures on the International Space Station (ISS) to maintain crew health and combat the negative effects of long-duration spaceflight on the human body. Most ISS exercise countermeasures system (CMS) equipment rely heavily on the use of textile and wire ropes to transmit resistive loads and provide stability in a microgravity environment. For a variety of reasons, including challenges in simulating microgravity environments for testing and limits on time available for life cycle testing, the textiles and wire ropes have contributed significantly to on-orbit planned and unplanned maintenance time. As a result, continued ground testing and on-orbit experience since the first expedition on the ISS in 2000 provide valuable data and lessons learned in materials selection, applications, and design techniques to increase service life of these ropes. This paper will present a review of the development and failure history of textile and wire ropes for four exercise countermeasure systems-the Treadmill with Vibration Isolation and Stabilization (TVIS) System, Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) System, Interim Resistive Exercise Device (IRED), and the Advanced Resistive Exercise Device (ARED)-to identify lessons learned in order to improve future systems. These lessons learned, paired with thorough testing on the ground, offer a forward path towards reduced maintenance time and up-mass for future space missions.

  13. Hybrid Lateral Transshipments in a Multi-Location Inventory System

    NARCIS (Netherlands)

    Teunter, Ruud; Paterson, Colin; Glazebrook, K.

    2010-01-01

    In managing networks of stock holding locations, two approaches to the pooling of inventory have been proposed. Reactive transshipm nts respond to stockouts at a location by moving inventory from elsewhere within the network, while proactive redistribution of stock seeks to minimise the chance of fu

  14. Identification of problems when using long high voltage AC cable in transmission system I: Switching transient problems

    DEFF Research Database (Denmark)

    Rahimi, Saeed; Wiechowski, W.; Randrup, M

    2008-01-01

    Due to political and environmental pressures from the public and government side, upgrading and building new transmission facilities are becoming more and more difficult and in some cases the expansion of overhead transmission lines are impossible. This means that underground cable technology...

  15. Stochastic Response of an Inclined Shallow Cable with Linear Viscous Dampers under Stochastic Excitation

    DEFF Research Database (Denmark)

    Zhou, Qiang; Nielsen, Søren R.K.; Qu, Weilian

    2010-01-01

    at the dampers location and the first sine term as shape functions, a reduced four-degree-of-freedom system of nonlinear stochastic ordinary differential equations are derived to describe dynamic response of the cable. Since only polynomial-type terms are contained, the fourth-order cumulant-neglect closure......Considering the coupling between the in-plane and out-of-plane vibration, the stochastic response of an inclined shallow cable with linear viscous dampers subjected to Gaussian white noise excitation is investigated in this paper. Selecting the static deflection shape due to a concentrated force...

  16. The Analysis of Static Performance of Geiger System Cable Dome and System Improvement%盖格体系索穹顶静力特性分析及体系改进

    Institute of Scientific and Technical Information of China (English)

    郭远翔; 林亮洪

    2011-01-01

    This essay is based on a calculation example, to analyse it with the help of SAP2000, then discuss the relationship of the change of internal forces of different structural memebers and nodal displacements with the change of various load sizes for cable dome of Geiger system, obtain the static structural characteristics of such cable dome system. With the analizing of the calculation results, conclude the point that should be noted seriously when designing cable dome of Geiger system-the inner ring of cable is very easy to relax, at the same time discusses the solution to this problem. Then the effectiveness of the approach of replacing the easy-to-relax cable with rigid cable by analyzing an example is demonstrated.%从一个算例出发,运用sap2000对算例进行计算.讨论盖格体系索穹顶各节点位移以及各构件内力随荷载大小的变化情况,得出盖格体系索穹顶的结构静力特性.从对计算结果的分析,得出盖格体系设计时需十分注意的问题——内圈脊索很容易松弛,并对解决这一问题的方法进行探讨,且以一个实例论证用劲性索替换容易松弛的索这一方法的有效性.

  17. Optimal energy harvesting from vortex-induced vibrations of cables.

    Science.gov (United States)

    Antoine, G O; de Langre, E; Michelin, S

    2016-11-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension.

  18. Optimal energy harvesting from vortex-induced vibrations of cables

    Science.gov (United States)

    Antoine, G. O.; de Langre, E.; Michelin, S.

    2016-11-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension.

  19. Subpixel Target Location Techniques for 3-D Coordinate Measuring System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The close photogrammetric 3-D coordinate measurement is a new measuring technology in the fields of the coordinate measurement machine (CMM) in recent years. In this method, we usually place some targets on the measured object and take image of targets to determine the object coordinate. The subpixel location of target image plays an important role in high accuracy 3-D coordinate measuring procedure. In this paper, some subpixel location methods are reviewed and some factors which affect location precision are analyzed. Then we propose bilinear interpolation centroid algorithm. The experiments have shown this algorithm can improve accuracy of target centroid by increasing available pixels.

  20. A novel assistance data processing method for AGPS location system

    Institute of Scientific and Technical Information of China (English)

    LEI Jian-jun; XIA Ying; Haeyoung Bae

    2007-01-01

    A method for efficiently transmitting location assistance information to an MS (mobile station) over a control channel with minimal impact on the capacity of the control channel. A location server provides a difference between satellite positions that have been computed using Almanac data and Ephemeris data. Sending only the difference between the positions and satellite clock corrections computed using the two different data types. The total amount of information to be transmitted to a MS is significantly reduced. Furthermore, by providing rate of change information, the method allows the location assistance information to remain valid for a relatively long time after it has been received by the MS.

  1. Single Ended Fault Location Estimation for EHV Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qing-chao张庆超; LI Hui李晖; D. W. P. Thomas

    2004-01-01

    A novel numerical algorithm for fault location estimation of single-phase-to-earth fault on EHV transmission lines is presented in this paper. The method is based on one-terminal voltage and current data and is used in a procedure that provides the automatic determination of faulted types and phases, rather than requires engineer to specify them. The loop and nodal equations comparing the faulted phase to non-faulted phases of multi-parallel lines are introduced in the fault location estimation models, in which source impedance of remote end is not involved. Precise algorithms of locating fault are derived. The effect of load flow and fault resistance,on the location accuracy, are effectively eliminated. The algorithms are demonstrated by digital computer simulations.

  2. Multistrand superconductor cable

    Science.gov (United States)

    Borden, Albert R.

    1985-01-01

    Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.

  3. Technologies for Improved Reliability of Shielded Power Cable and Characterization of Capacitor Film Energy Density

    Science.gov (United States)

    Shu, Wen

    Partial Discharge (PD), a partial breakdown of insulation between high voltage electrodes, reduces cable reliability. Understanding electromagnetic propagation of PD-induced pulses in shielded power cable, including attenuation and dispersion, is essential to the application of PD diagnostics and, especially, PD location. Dispersion is caused by the transition of cable semicon-ducting layers (between the cable conductors and dielectric) from "resistive" at low frequency to "capacitive" at high frequency. Methods are presented to compute dispersion as a function of semiconducting material properties and evaluate the effect of dispersion on pulse characteristics (amplitude, shape, and width, etc.) as a function of distance propagated, the results of which are applied to investigate the effects of dispersion for PD detection and location. The location error induced by dispersion can be compensated from calibration. Electrochemical degradation of cable dielectrics, known as "water treeing", is one of the leading cause of premature failures in underground shielded power cable. Silane-based fluid has been used successfully for decades to rejuvenate HMWPE and XLPE dielectric cables to "cure" existing water trees and extend cable life. However the ability of the treatment to inhibit future water tree initiation is not known. A method for silane fluid treatment of un-aged cable insulation and semicon was developed based on the use of GC/MS to determine curing of the fluid within the dielectric. A wet electrical aging test at 5 kV/mm (127 V/mil) based on a sample which includes semicon electrodes on both sides of the XLPE insulation with a water electrode in contact with one semicon layer was used to age untreated samples, samples treated prior to the test, and samples treated at the mid-time of the test (3500 hrs). The result of aging is analyzed by microscopic examination to determine the number, length and types of water trees. The mechanism by which the silane

  4. The Impact of Intelligent Transport Systems on Office Location Attractiveness: Testing the Predictive Validity of a Location Choice Model

    NARCIS (Netherlands)

    Argiolu, R.; Van der Heijden, R.; Bos, I.; Marchau, V.A.W.J.

    2013-01-01

    In recent years, a model was developed describing effects of Intelligent Transport Systems (ITS) on location preferences of office-keeping organisations in urbanised. The model is based on a Hierarchical Information Integration Approach, using Stated Preference data. The model indicates that ITS

  5. Estimation of Medium Voltage Cable Parameters for PD Detection

    DEFF Research Database (Denmark)

    Villefrance, Rasmus; Holbøll, Joachim T.; Henriksen, Mogens

    1998-01-01

    Medium voltage cable characteristics have been determined with respect to the parameters having influence on the evaluation of results from PD-measurements on paper/oil and XLPE-cables. In particular, parameters essential for discharge quantification and location were measured. In order to relate...

  6. Ground Loop Impedance of Long EHV Cable Lines

    DEFF Research Database (Denmark)

    Ohno, Teruo; Bak, Claus Leth; Sørensen, Thomas K.

    2012-01-01

    The distance protection scheme without communication is often applied to the backup protection of EHV cable lines. For a reliable operation of a ground distance relay, the ground loop impedance of EHV cable lines needs to have a linear relationship to the distance from the relay location to the f...

  7. Assessment of seafloor burial of proposed OTEC power-transmission cables

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    This study assesses the need for protection of the seafloor OTEC power transmission cables, identifies the means, or development requirements, for accomplishing the required protection, and determines the costs and benefits associated with this protection. Protection of the bottom cable along the entire route from the shoreline to the riser cable were evaluated at four specific sites. Three of the four sites are ''island sites''; they are immediately offshore of: (1) Kahe Point, Oahu, Hawaii; (2) Punta Yeguas, Puerto Rico; and (3) Cabras Island, Guam. The fourth site is in the Gulf of Mexico, due West of Tampa, Florida. All four sites are located in the tropical zones and are fully exposed to open ocean wind waves and currents. Cable routes from the shore to platform site are generally normal to the depth contours fronting the offshore slopes. All four sites are subject to severe hurricane winds and wave action. A total of 1061 sumarine communication cable faults were accumulated and analyzed during the initial portion of this study. These faults cover 101 years (1879 to 1980) of data collection and are reported in probabilistic terms keyed to water depth. Chafing and corrosion were found to be the most common hazard causing just over half of the reported incidents. Fishing activities, specifically trawlers and dredgers, wee the second most common hazard, accounting for approximately one-quarter of the reported incidents. The status of seafloor cable protection technology is also addressed in this study. A comprehensive summary identifying the most suitable commercial systems has been conducted. Both cable and pipeline protection systems were included as well as previous relevant experience and operating conditions.

  8. Offshore Substation Locating in Wind Farms Based on Prim Algorithm

    DEFF Research Database (Denmark)

    Hou, Peng; Hu, Weihao; Chen, Zhe

    2015-01-01

    The investment of offshore wind farm is large while the cost on electrical system can take up to 15% of the total costs. In order to reduce the cost, it is desirable to optimize the electrical system layout in design phase. Since the location of offshore substation (OS) is highly related to the e......The investment of offshore wind farm is large while the cost on electrical system can take up to 15% of the total costs. In order to reduce the cost, it is desirable to optimize the electrical system layout in design phase. Since the location of offshore substation (OS) is highly related...... to the electrical system layout, the optimal layout design work should be done with the consideration of the impact of the location of offshore substation on the submarine cable connection layout to minimize the investment of cables. This paper addresses a new method to optimize the OS location together...

  9. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  10. Total Magnetic Field Signatures over Submarine HVDC Power Cables

    Science.gov (United States)

    Johnson, R. M.; Tchernychev, M.; Johnston, J. M.; Tryggestad, J.

    2013-12-01

    Mikhail Tchernychev, Geometrics, Inc. Ross Johnson, Geometrics, Inc. Jeff Johnston, Geometrics, Inc. High Voltage Direct Current (HVDC) technology is widely used to transmit electrical power over considerable distances using submarine cables. The most commonly known examples are the HVDC cable between Italy and Greece (160 km), Victoria-Tasmania (300 km), New Jersey - Long Island (82 km) and the Transbay cable (Pittsburg, California - San-Francisco). These cables are inspected periodically and their location and burial depth verified. This inspection applies to live and idle cables; in particular a survey company could be required to locate pieces of a dead cable for subsequent removal from the sea floor. Most HVDC cables produce a constant magnetic field; therefore one of the possible survey tools would be Marine Total Field Magnetometer. We present mathematical expressions of the expected magnetic fields and compare them with fields observed during actual surveys. We also compare these anomalies fields with magnetic fields produced by other long objects, such as submarine pipelines The data processing techniques are discussed. There include the use of Analytic Signal and direct modeling of Total Magnetic Field. The Analytic Signal analysis can be adapted using ground truth where available, but the total field allows better discrimination of the cable parameters, in particular to distinguish between live and idle cable. Use of a Transverse Gradiometer (TVG) allows for easy discrimination between cable and pipe line objects. Considerable magnetic gradient is present in the case of a pipeline whereas there is less gradient for the DC power cable. Thus the TVG is used to validate assumptions made during the data interpretation process. Data obtained during the TVG surveys suggest that the magnetic field of a live HVDC cable is described by an expression for two infinite long wires carrying current in opposite directions.

  11. Application study on the first cable-stayed bridge with CFRP cables in China

    Directory of Open Access Journals (Sweden)

    Kuihua Mei

    2015-08-01

    Full Text Available In order to push forward the development of CFRP cable-stayed bridge and accumulate experiences, the study on the application of the first cable-stayed bridge with CFRP cables in China was carried out. The design essentials of main components of the bridge were introduced and its integral performances, including static properties, dynamic properties and seismic response were analyzed using finite element method. A new bond-type anchorage was developed and the processes of fabricating and installing CFRP cables were elaborated. Based on the results of construction simulation, a tension scheme for bridge was propound. During constructing, the stresses and displacement of girder and pylon, as well as the forces and stresses of cables, were tested. The results indicate that all sections of the bridge could meet the requirements of the ultimate bearing capacity and normal service; the performance of the anchorage is good and the stresses in each cable system are similar; the tested values accord well with the calculated values. Further, creep deformation of the resin in anchorages under service load is not obvious. All these results demonstrate that the first application of CFRP cables in the cable-stayed bridge in China is successful.

  12. Cable Fault Traveling Wave on Line Monitoring System Based on LabVIEW%基于LabVIEW的电缆故障行波在线监测系统

    Institute of Scientific and Technical Information of China (English)

    段金英

    2011-01-01

    The buried cables effected by complex, uneven electric field and thermal field, the surrounding environment and many other factors,has high rate of accidents. This paper presented a better real-time monitoring system,with the use of the development platform of National Instruments Corporation Lab VIEW virtual instrument and data acquisition cards, collects the continuous voltage,current of cable line and other parameters,to monitor the operation of transmission lines,The monitoring system realizes the fault current on-line monitoring through the device at the scene access to the Hall sensor cable voltage and current signals from the data acquisition card on the fault wave pop electric high-speed sampling and storage control, with the use of graphical programming language designed to monitor PC interface. Experimental results show that the system can accurately record fault current waveforms, amplitude, provide important data analysis of fault type and location.%针对埋地电缆敷设复杂,发生事故率高的情况,提出了使用LabVIEW和数据采集卡,不间断采集电缆线路上的电压、电流等参数,监视输电线路运行状况,并通过TCP节点,构建了一个实时性较好的监测系统.该监控系统通过装在现场的霍尔传感器获取电缆的电压电流信号,由数据采集卡对故障电流行波进行高速采样和存储控制,利用具有图形化的编程语言设计上位机监控界面,实现了故障电流的在线监测.试验结果表明:该系统能够准确地记录故障电流波形、幅值,为故障类型分析和定位提供了重要数据.

  13. 33 CFR 209.310 - Representation of submarine cables and pipelines on nautical charts.

    Science.gov (United States)

    2010-07-01

    ... cables and pipelines on nautical charts. 209.310 Section 209.310 Navigation and Navigable Waters CORPS OF... of submarine cables and pipelines on nautical charts. (a) The policy of the Corps of Engineers with respect to showing the locations of submarine cables and pipelines on nautical charts published by...

  14. Enhanced lateral transshipments in a multi-location inventory system

    NARCIS (Netherlands)

    Paterson, Colin; Teunter, Ruud; Glazebrook, Kevin

    2012-01-01

    In managing an inventory network, two approaches to the pooling of stock have been proposed. Reactive transshipments respond to shortages at a location by moving inventory from elsewhere within the network, while proactive stock redistribution seeks to minimize the chance of future stockouts. This p

  15. Reconfigurable Buoyant Cable Antenna with Improved Gain

    Science.gov (United States)

    2010-07-28

    consists of a number of connected streamer cable sections, which each comprise a mechanical jacket surrounding a hollow core enclosing seismic sensor and...of insulation. A buoyancy layer/ jacket is either injection molded or extruded in place onto the core to make the final structure a solid object...systems: [0008] U.S. Patent No. 5,745,436, issued April 28, 1998, to Bittleston, discloses a semi-dry marine seismic streamer cable that

  16. 77 FR 61351 - Cable Television Technical and Operational Requirements

    Science.gov (United States)

    2012-10-09

    ...In this document, the Federal Communications Commission proposes to update technical and operational rules related to cable television systems and other multichannel video programming distributors that operate coaxial cable systems. The Commission seeks comments on rules that would update its minimum signal quality standards and signal leakage detection and monitoring for digital transmission. Additionally, the Commission proposes numerous corrections and updates to its to its cable television technical rules.

  17. OPF-Based Optimal Location of Two Systems Two Terminal HVDC to Power System Optimal Operation

    Directory of Open Access Journals (Sweden)

    Mehdi Abolfazli

    2013-04-01

    Full Text Available In this paper a suitable mathematical model of the two terminal HVDC system is provided for optimal power flow (OPF and optimal location based on OPF such power injection model. The ability of voltage source converter (VSC-based HVDC to independently control active and reactive power is well represented by the model. The model is used to develop an OPF-based optimal location algorithm of two systems two terminal HVDC to minimize the total fuel cost and active power losses as objective function. The optimization framework is modeled as non-linear programming (NLP and solved by Matlab and GAMS softwares. The proposed algorithm is implemented on the IEEE 14- and 30-bus test systems. The simulation results show ability of two systems two terminal HVDC in improving the power system operation. Furthermore, two systems two terminal HVDC is compared by PST and OUPFC in the power system operation from economical and technical aspects.

  18. Condition Monitoring of Power Cables

    OpenAIRE

    Lewin, P L; L. Hao; Swaffield, D J; Swingler, S.G.

    2007-01-01

    A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, funded through the EPSRC Supergen V, UK Energy Infrastructure (AMPerES) grant in collaboration with UK ...

  19. Cable Television; A Bibliographic Review.

    Science.gov (United States)

    Schoenung, James

    This bibliographic review of publications in the field of cable television begins with an introduction to cable television and an outline of the history and development of cable television. Particular attention is given to the regulatory activities of the Federal Communications Commission and the unfulfilled potential of cable television. The…

  20. Coding of object location in the vibrissal thalamocortical system.

    Science.gov (United States)

    Yu, Chunxiu; Horev, Guy; Rubin, Naama; Derdikman, Dori; Haidarliu, Sebastian; Ahissar, Ehud

    2015-03-01

    In whisking rodents, object location is encoded at the receptor level by a combination of motor and sensory related signals. Recoding of the encoded signals can result in various forms of internal representations. Here, we examined the coding schemes occurring at the first forebrain level that receives inputs necessary for generating such internal representations--the thalamocortical network. Single units were recorded in 8 thalamic and cortical stations in artificially whisking anesthetized rats. Neuronal representations of object location generated across these stations and expressed in response latency and magnitude were classified based on graded and binary coding schemes. Both graded and binary coding schemes occurred across the entire thalamocortical network, with a general tendency of graded-to-binary transformation from thalamus to cortex. Overall, 63% of the neurons of the thalamocortical network coded object position in their firing. Thalamocortical responses exhibited a slow dynamics during which the amount of coded information increased across 4-5 whisking cycles and then stabilized. Taken together, the results indicate that the thalamocortical network contains dynamic mechanisms that can converge over time on multiple coding schemes of object location, schemes which essentially transform temporal coding to rate coding and gradual to labeled-line coding.

  1. The Coupling Effect of Spatial Reticulated Shell Structure with Cables

    Institute of Scientific and Technical Information of China (English)

    MA Jun; ZHOU Dai; FU Xu-chen

    2005-01-01

    The spatial reticulated shell structure with cables (RSC) is a kind of coupling working system, which consists of flexible cables, reticulated shell structure (RS) and tower columns. The dynamic analysis of RSC based on the coupling model was carried out. Three kinds of elements such as the spatial bar element, cable element and beam element were introduced to analyze the reticulated shell, cable and tower column respectively. Furthermore,such parameter influences as structural boundary conditions, grid configuration, the span-to-depth ratio and the arrangement of cable system upon structural dynamics were analyzed. The structural vibration modes can be divided into four groups based on some numerical examples. And the frequencies in the same group are very close while the frequencies in different groups are different from each other obviously. It is clear that the sequence of the appearance of the each mode group heavily depends on the comparative stiffness of the tower column system, RS and cables.

  2. Practical Damping Identification of FAST Cable Suspension

    Directory of Open Access Journals (Sweden)

    Jinghai Sun

    2014-03-01

    Full Text Available FAST focus cabin is suspended and driven by 6 parallel large span cables. Low stiffness of cables makes the cabin sensitive to disturbance and difficult to control. Structural damping then becomes a key factor that can improve control ability. Therefore, a reasonable damping estimation is important for system design. In this paper, a practical damping identification method is developed based on Ibrahim-time-domain algorithm. The method shows satisfied performance on accuracy and reliability in simulation test and is utilized in vibration experiments to identify damping ratios of both single cable model and FAST 3 m scale cable suspension model. Finally, a preliminary analysis of the damping properties is given out based on the results of identification.

  3. Energy dispatching analysis of lightning surges on underground cables in a cable connection station

    Energy Technology Data Exchange (ETDEWEB)

    Hong-Chan Chang; Fu-Hsien Chen; Tai-Hsiang Chen [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei (China); Cheng-Chien Kuo [Department of Electrical Engineering, St. John' s University, 499, Sec. 4, TamKing Rd., Tamsui, Taipei (China)

    2011-01-15

    The paper aimed to simulate the transient over-voltage phenomena which occur at 345 kV and 161 kV underground cables, when lighting strikes on or near the cable connection station, by using the Electro-Magnetic Transients Program (EMTP). A feasibility study on changing related parameters, as well as cable connections and grounding methods to reduce the impact caused by lightning strikes, will be thoroughly conducted. The various components required for a detailed simulation including; lightning surges, transmission line and tower, arrester, and underground cables are all considered. Then, the transient voltage of the cables will be analyzed under different situations including; connection methods, grounding locations, length of the grounding wire of arrester, and the grounding resistance for different locations. The simulation results show that the length of the grounding wire is more sensitive to the transient over-voltage which occurred when a common grounding topology was adopted. In contrast, the use of an independent grounding topology resulted in a reduction of the grounding resistance, which effectively decreased the over-voltage, thereby avoiding surpassing the shielding voltage level of the cable, caused by the rise of ground voltage. (author)

  4. Energy dispatching analysis of lightning surges on underground cables in a cable connection station

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hong-Chan, E-mail: hcchang@mail.ntust.edu.t [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei, Taiwan (China); Chen, Fu-Hsien, E-mail: fu@mail.sju.edu.t [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei, Taiwan (China); Kuo, Cheng-Chien, E-mail: cckuo@mail.sju.edu.t [Department of Electrical Engineering, St. John' s University, 499, Sec. 4, TamKing Rd., Tamsui, Taipei, Taiwan (China); Chen, Tai-Hsiang, E-mail: thchen@yahoo.com.t [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei, Taiwan (China)

    2011-01-15

    The paper aimed to simulate the transient over-voltage phenomena which occur at 345 kV and 161 kV underground cables, when lighting strikes on or near the cable connection station, by using the Electro-Magnetic Transients Program (EMTP). A feasibility study on changing related parameters, as well as cable connections and grounding methods to reduce the impact caused by lightning strikes, will be thoroughly conducted. The various components required for a detailed simulation including; lightning surges, transmission line and tower, arrester, and underground cables are all considered. Then, the transient voltage of the cables will be analyzed under different situations including; connection methods, grounding locations, length of the grounding wire of arrester, and the grounding resistance for different locations. The simulation results show that the length of the grounding wire is more sensitive to the transient over-voltage which occurred when a common grounding topology was adopted. In contrast, the use of an independent grounding topology resulted in a reduction of the grounding resistance, which effectively decreased the over-voltage, thereby avoiding surpassing the shielding voltage level of the cable, caused by the rise of ground voltage.

  5. End moldings for cable dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Roose, L.D.

    1993-12-31

    End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble- free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves.

  6. Electromagnetic Transients in Power Cables

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    of electromagnetic phenomena associated to their operation, among them electromagnetic transients, increased as well. Transient phenomena have been studied since the beginning of power systems, at first using only analytical approaches, which limited studies to more basic phenomena; but as computational tools became...... concerning HVAC cables. An important topic that is not covered in this book is measurements protocols/ methods. The protocols used when performing measurements on a cable depend on what is to be measured, the available equipment and accessibility. Readers interested in the topic are referred to search....... The chapter ends by proposing a systematic method that can be used when doing the insulation co-ordination study for a line, as well as the modelling requirements, both modelling depth and modelling detail of the equipment, for the study of the different types of transients followed by a step-by-step generic...

  7. Research and Design of On-line Monitoring System of XLPE Cable Based on Water Tree Phenomenon%基于水树枝现象XLPE电缆在线监测系统的研究与设计

    Institute of Scientific and Technical Information of China (English)

    周笑阳; 杨建华; 卢伟

    2015-01-01

    基于交联聚乙烯(XLPE)电缆水树状老化的原理,直流分量法和交流叠加法是两种有效的XLPE电缆在线监测方法。设计了综合上述两种方法的在线监测系统,其中包括设计方案、系统构成、关键技术等。结果表明:设计的XLPE电缆在线监测系统能够反映运行中电缆绝缘的老化程度,实现了XLPE电缆的在线监测。%Based on the theory of water tree ageing of XLPE cable, the DC component method and AC superposition method are effective methods for on-line monitoring of XLPE cable. An on-line monitoring system of XLPE cable based on the above two methods was designed, which included design plan, system construction, and key technology. The experiment results show that the on-line monitoring system can reflect the ageing degree of the running cable, and realize the on-line monitoring of the cable.

  8. Study on the Configuration of Towed Flexible Cables

    Institute of Scientific and Technical Information of China (English)

    陈敏康; 张仁颐

    2003-01-01

    Based on the fundamental equation of flexible cable dynamics for a towed system, an easily solved mathematical model is set up in this paper by means of appropriate simplification. Several regular patterns of spatial motion of towed flexible cables in water are obtained through numerical simulation with the finite difference method, and then modification and verification by trial results at sea. A technical support is provided for the towing ship to maneuver properly when a flexible cable is towed. Furthermore, the relations between two towed flexible cables, which are towed simultaneously by a ship, are investigated. The results show that the ship towing two flexible cables is safe under the suggested arrangement of two winches for the towing system, and the coiling/uncoiling sequences of the cables as well as the suggested way of maneuvering.

  9. ALOHA Cabled Observatory (ACO): Acoustic Doppler Current Profiler (ADCP): Temperature

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The University of Hawaii's ALOHA ("A Long-term Oligotrophic Habitat Assessment") Cabled Observatory (ACO) is located 100 km north of the island of Oahu, Hawaii (22...

  10. ALOHA Cabled Observatory (ACO): Acoustic Doppler Current Profiler (ADCP): Velocity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The University of Hawaii's ALOHA ("A Long-term Oligotrophic Habitat Assessment") Cabled Observatory (ACO) is located 100 km north of the island of Oahu, Hawaii (22...

  11. Modeling of cable vibration effects of cable-stayed bridges

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The analysis of dynamic responses of cable-stayed bridges subjected to wind and earthquake loads generallyconsiders only the motions of the bridge deck and pylons. The influence of the stay cable vibration on the responses of the bridgeis either ignored or considered by approximate procedures. The transverse vibration of the stay cables, which can be significant insome cases, are usually neglected in previous research. In the present study, a new three-node cable element has been developed tomodel the transverse motions of the cables. The interactions between the cable behavior and the other parts of the bridgesuperstructure are considered by the concept of dynamic stiffness. The nonlinear effect of the cable caused by its self-weight isincluded in the formulation. Numerical examples are presented to demonstrate the accuracy and efficiency of the proposed model.The impact of cable vibration behavior on the dynamic characteristics of cable-stayed bridges is discussed.

  12. Aerodynamic stability of cable-supported bridges using CFRP cables

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xin-jun; YING Lei-dong

    2007-01-01

    To gain understanding of the applicability of carbon fiber reinforced polymer (CFRP) cable in cable-supported bridges, based on the Runyang Bridge and Jinsha Bridge, a suspension bridge using CFRP cables and a cable-stayed bridge using CFRP stay cables are designed, in which the cable's cross-sectional area is determined by the principle of equivalent axial stiffness.Numerical investigations on the aerodynamic stability of the two bridges are conducted by 3D nonlinear aerodynamic stability analysis. The results showed that as CFRP cables are used in cable-supported bridges, for suspension bridge, its aerodynamic stability is superior to that of the case using steel cables due to the great increase of the torsional frequency; for cable-stayed bridge,its aerodynamic stability is basically the same as that of the case using steel stay cables. Therefore as far as the wind stability is considered, the use of CFRP cables in cable-supported bridges is feasible, and the cable's cross-sectional area should be determined by the principle of equivalent axial stiffness.

  13. Smart Waste Collection System Based on Location Intelligence

    DEFF Research Database (Denmark)

    Lopez, Jose Manuel Guterrez Lopez; Jensen, Michael; Andreasen, Morten Henius

    2015-01-01

    (IoT) integration with data access networks, Geographic Information Systems (GIS), combinatorial optimization, and electronic engineering can contribute to improve cities’ management systems. We present a waste collection solution based on providing intelligence to trashcans, by using an IoT prototype...

  14. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  15. Environmental Monitoring, Air Quality - MO 2011 Facility Air Locations - Missouri Emmissions Inventory System (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — This data set includes locations from the Missouri Emissions Inventory System (MOEIS) database. Locational data was obtained using a variety of methods including but...

  16. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be...

  17. Dimensioning of Photovoltaic Generation Systems Located in Medellin City

    Directory of Open Access Journals (Sweden)

    Laura Herrera

    2013-11-01

    Full Text Available Photovoltaic systems are one of the most efficient solutions to the energy crisis of the last decades. The implementation of these systems will be economically feasible in most cases, due to extensive number of advantages that they exhibit. However, for the sake of better economic performance, it is important to generate different strategies for their management. This paper presents an optimization strategy based on the redistribution of power generated, which seeks to stop spending as it is produced to take advantage of those times when energy rates are higher, making use of a storage system. The steps for the photovoltaic system design with these criteria and economic analysis will be presented.

  18. Potential applications of cable television (CATV) to the FEMA (Federal Emergency Management Agency) communications mission

    Science.gov (United States)

    Gilligan, D. D.; Abtahi, H.; Becker, J. R., Jr.; Frantz, S. W.

    1983-07-01

    The history, technology, economics, regulation and vulnerability to electromagnetic pulse (EMP) effects of cable television are examined. Recommendations are made concerning FEMA integration of cable television systems into the FEMA emergency communications system and the protection of cable television systems for EMP effects.

  19. ACCURACY ANALYSIS OF PASSIVE LOCATION SYSTEM WITH PHASE DIFFERENCE RATE MEASUREMENT

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The conventional mono-station passive location techniques of direction finding are low in speed and accuracy, due to the little information available. In this paper, a novel measurement-rate (derivative) of phase difference from a two-element antenna array (interferometer) is introduced, accuracy of a passive location system with this measurement and directions of arrival (DOA) is analyzed, and the Cramer-Rao bound of location error of this system for 3D location is examined by simulations.

  20. Optimal PMU location in power systems using MICA

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Taher

    2016-03-01

    Full Text Available This study presented a modified imperialist competitive algorithm (MICA for optimal placement of phasor measurement units (PMUs in normal and contingency conditions of power systems. The optimal PMU placement problem is used for full network observability with the minimum number of PMUs. For this purpose, PMUs are installed in strategic buses. Efficiency of the proposed method is shown by the simulation results of IEEE 14, 30, 57, and 118-bus test systems. Results of the numerical simulation on IEEE-test systems indicated that the proposed technique provided maximum redundancy measurement and minimum request of PMUs so that the whole system could be topologically observable by installing PMUs on the minimum system buses. To verify the proposed method, the results are compared with those of some recently reported methods. When MICA is used for solving optimal PMU placement (OPP, the number of PMUs would be usually equal to or less than those of the other existing methods. Results indicated that MICA is a very fast and accurate algorithm for OPP solution.

  1. Truncated Cables1 causes agenesis of the corpus callosum in mice.

    Science.gov (United States)

    Mizuno, Seiya; Tra, Dinh T H; Mizobuchi, Atsushi; Iseki, Hiroyoshi; Mizuno-Iijima, Saori; Kim, Jun-Dal; Ishida, Junji; Matsuda, Yoichi; Kunita, Satoshi; Fukamizu, Akiyoshi; Sugiyama, Fumihiro; Yagami, Ken-ichi

    2014-03-01

    Agenesis of the corpus callosum (ACC) is a congenital abnormality of the brain structure. More than 60 genes are known to be involved in corpus callosum development. However, the molecular mechanisms underlying ACC are not fully understood. Previously, we produced a novel transgenic mouse strain, TAS, carrying genes of the tetracycline-inducible expression system that are not involved in brain development, and inherited ACC was observed in the brains of all homozygous TAS mice. Although ACC was probably induced by transgene insertion mutation, the causative gene and the molecular mechanism of its pathogenesis remain unclear. Here, we first performed interphase three-color fluorescence in situ hybridization (FISH) analysis to determine the genomic insertion site. Transgenes were inserted into chromosome 18 ∼12.0 Mb from the centromere. Gene expression analysis and genomic PCR walking showed that the genomic region containing exon 4 of Cables1 was deleted by transgene insertion and the other exons of Cables1 were intact. The mutant allele was designated as Cables1(TAS). Interestingly, Cables1(TAS) mRNA consisted of exons 1-3 of Cables1 and part of the transgene that encoded a novel truncated Cables1 protein. Homozygous TAS mice exhibited mRNA expression of Cables1(TAS) in the fetal cerebrum, but not that of wild-type Cables1. To investigate whether a dominant negative effect of Cables1(TAS) or complete loss of function of Cables1 gives rise to ACC, we produced Cables1-null mutant mice. ACC was not observed in Cables1-null mutant mice, suggesting that a dominant negative effect of Cables1(TAS) impairs callosal formation. Moreover, ACC frequency in Cables1(+/TAS) mice was significantly lower than that in Cables1(-/TAS) mice, indicating that wild-type Cables1 interfered with the dominant negative effect of Cables1(TAS). This study indicated that truncated Cables1 causes ACC and wild-type Cables1 contributes to callosal formation.

  2. Mobile system for locating and tracking vehicles in distress

    Science.gov (United States)

    Landi, Giuliano; Stoica, Axente D.

    2000-02-01

    This report relates to a mobile system for tracking and protection of vehicles owned by some banking organizations, security institutions or by some social service for fire, medical rescue or taxicabs, by an operator placed also aboard of a vehicle in which he has at his disposal all the necessary means for precise determination of the position and the state of each vehicle from the fleet that is under his surveying. Therefore in contrast to the operating mode of the localization systems known in present and which have in its composition a stable center for permanent surveying, the operator of the system presented in this report can intervene personally and in an efficient mode in the aid of the vehicle in distress.

  3. Statics and Dynamics of Offshore Cable and Flexible Pipe Systems Statique et dynamique des câbles flexibles en mer

    Directory of Open Access Journals (Sweden)

    Peyrot A. H.

    2006-11-01

    Full Text Available A new method for the static and dynamic analysis of offshore cable structures is presented. These structures may consist of floating platform, buoys, weights, anchors, etc. interconnected by arbitrary arrangements of cables and flexible pipes. Displacements or forces can be specified at any number of nodal points and wave or current interaction be simulated. The efficiency of the method is demonstrated by several applications: dynamic response of deep-water oil production platform, anchor drop, sonar towing, dynamic stiffness of mooring lines, tanker loading systems with flexible pipes, etc. Cet article présente une méthode de calcul pour les structures marines comportant des câbles et des tuyaux flexibles. La méthode est applicable à des réseaux de câbles ou de flexibles reliant des plates-formes flottantes, des bouées, des ancrages, etc. Des déplacements ou des forces peuvent être imposés en un nombre quelconque de nSuds. L'action du courant et de la houle est prise en compte. La méthode a été utilisée pour l'étude de nombreux systèmes de câbles et de flexibles. Les résultats indiquent une excellente performance des calculs proposés.

  4. 唐山市基于有线电视的智能家居系统%The Smart Home System Based on Cable TV in Tangshan

    Institute of Scientific and Technical Information of China (English)

    康利利

    2016-01-01

    The article briefly introduces the smart home system based on cable TV of tangshan.Smart home is a new generation of information technology support,the next generation of urban form in the innovation envi-ronment of the knowledge society.Smart home,based on Internet of things,is the application of the tools and methods of the comprehensive integration means,i.e.,a new generation of information technology such as cloud computing,and wikis,social networking,FabLab,LivingLab,etc.It is conducive to the ecology of in-novating.Thus this paper briefly introduces the construction of smart home based on cable TV in Tangshan.%智能家居是新一代信息技术支撑、知识社会下一代创新环境下的城市形态,是基于物联网、云计算等新一代信息技术以及维基、社交网络、FabLab、LivingLab、综合集成法等工具和方法的应用,营造有利于创新涌现的生态。基于此,简要介绍唐山市基于有线电视智能家居系统的构建情况。

  5. Vertical vibration control system for PC cable-stayed bridge during cantilever construction; Shuketa jogedo seishin sochi ni yoru haridashi sekoji no PC shachokyo no seishin

    Energy Technology Data Exchange (ETDEWEB)

    Oshio, M.; Nakano, R.; Niihara, Y.; Yano, K.; Takeda, T. [Kajima Corp., Tokyo (Japan)

    1995-12-20

    A PC cable-stayed bridge under extension construction having long span length may have long-cycle vibration generated because of wind. The vibration puts workers working on main girders into a state of seasick causing the workability to drop. Therefore, with an objective to reduce vibration occurring on the main girders during construction, discussions were given on application of an active type vertical vibration absorbing device. The vibration absorbing device is an active system that a weight is driven vertically by a hydraulic actuator. The device was developed with a target that damping ratio when a maximum extension is 120 m becomes three times that when no vibration is absorbed for a 5-span continuous PC cable-stayed bridge with a length of 675 m, a central span of 260 m, and a width of 11 m. A cage housing the weight is connected with the actuator at its top by using pins, and the weight is supported being suspended from the top of the actuator. Vibration is absorbed by utilizing reactive force generated when the weight is driven vertically by the hydraulic actuator. The hydraulic actuator contains a gas spring that supports the dead weight of the weight. Experiments have verified the effectiveness of the vertical vibration absorbing device. 4 refs., 12 figs., 3 tabs.

  6. Optical Fiber Grating Sensor for Force Measurement of Anchor Cable

    Institute of Scientific and Technical Information of China (English)

    JIANG Desheng; FU Jinghua; LIU Shengchun; SUI Lingfeng; FU Rong

    2006-01-01

    The development of the sensor suitable for measuring large load stress to the anchor cable becomes an important task in bridge construction and maintenance. Therefore, a new type of optical fiber sensor was developed in the laboratory - optical fiber grating sensor for force measurement of anchor cable (OFBFMAC). No similar report about this kind of sensor has been found up to now in China and other countries. This sensor is proved to be an effective way of monitoring in processes of anchor cable installation, cable cutting, cable force regulation, etc, with the accurate and repeatable measuring results. Its successful application in the tie bar cable force safety monitoring for Wuhan Qingchuan bridge is a new exploration of optical fiber grating sensing technology in bridge tie bar monitoring system.

  7. Electrothermal Coordination in Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Gudmundsdottir, Unnur Stella

    2013-01-01

    Electrothermal coordination (ETC) is introduced for cable based transmission grids. ETC is the term covering operation and planning of transmission systems based on temperature, instead of current. ETC consists of one part covering the load conditions of the system and one covering the thermal...... to be beneficial for both operator and system planner. It is shown how the thermal behavior can be monitored in real-time during normal dynamic load and during emergencies. In that way, ETC enables cables to be loaded above their normal rating, while maintaining high reliability of the system, which potentially...

  8. 47 CFR 73.6025 - Antenna system and station location.

    Science.gov (United States)

    2010-10-01

    ... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6025 Antenna system and station... should be used for the maximum radiation. The plot of the pattern should be oriented so that 0 degrees (True North) corresponds to the maximum radiation of the directional antenna or, alternatively in...

  9. 46 CFR 113.50-20 - Distribution of cable runs.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Distribution of cable runs. 113.50-20 Section 113.50-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Public Address Systems § 113.50-20 Distribution of cable runs. (a)...

  10. Analysis of the Sherlock II tip location system for inserting peripherally inserted central venous catheters.

    Science.gov (United States)

    Lelkes, Valdis; Kumar, Abhishek; Shukla, Pratik A; Contractor, Sohail; Rutan, Thomas

    2013-01-01

    Peripherally inserted central catheters (PICCs) are frequently placed at the bedside. The purpose of our study was to evaluate the efficacy of the Sherlock II tip location system (Bard Access Systems, Salt Lake City, UT), which offers electromagnetic detection of the PICC tip to assist the operator in guiding the tip to a desired location. We performed a retrospective review of patients who had a bedside PICC using the Sherlock II tip location system. Three hundred seventy-five of 384 patients (97.7%) had the catheter tip positioned appropriately. Our results suggest that the Sherlock II tip location system is an efficacious system for bedside PICC placement.

  11. 缆系海底观测网原型系统设计%Design of a prototype system for cabled seafloor observatory networks

    Institute of Scientific and Technical Information of China (English)

    吕枫; 彭晓彤; 周怀阳; 岳继光; 何斌

    2012-01-01

    A prototype system for cabled seafloor observatory networks was designed to continuously monitor the deep ocean with real-time and in-situ experiments. The system adopts up to 10 kV direct current power transmission and 100 Mb/s fiber-optic communication techniques. It consists of an undersea science node, an electro-optic submarine cable and a shore control station. The science node consists of an in-situ chemical analyzer, a dynamic environment monitor and a node junction box. The users could download science data from the data management subsystem in real-time , remotely monitor the instrument status with the power monitoring subsystem and carry out seafloor in-situ experiments. After tested under high pressure and in the laboratory tank for several times, the system has been operated stably in the East China Sea shallow water trial and the US Monterey Accelerated Research System (MARS) deep-sea experiment, and has obtained a large amount of high-resolution science data. Experiment results prove that the system design is reasonable and feasible, and the cabled seafloor observatory networks show advantages over traditional ocean observation approaches.%针对长期、实时和原位观测深海大洋的科学需求,设计了采用10 kV直流输电和100 Mb/s光纤通信的缆系海底观测网原型系统.该系统由海底科学节点、光电复合海缆和海岸控制基站组成,其中海底科学节点包括原位化学分析仪器、动力环境监测仪器和节点接驳盒.用户从数据管理子系统实时获取科学数据,从电能监控子系统远程监控仪器状态,进行海底原位实验.多次压力实验和水池联调后,该系统在中国东海浅海试验和美国蒙特雷湾海底观测网深海并网试验中运行稳定,从海底获取了大量高分辨率的科学数据.试验证明该设计合理可行,并体现缆系海底观测网较传统海洋观测方式有较大优势.

  12. Photovoltaic Power System and Power Distribution Demonstration for the Desert RATS Program

    Science.gov (United States)

    Colozza, Anthony; Jakupca, Ian; Mintz, Toby; Herlacher, Mike; Hussey, Sam

    2012-01-01

    A stand alone, mobile photovoltaic power system along with a cable deployment system was designed and constructed to take part in the Desert Research And Technology Studies (RATS) lunar surface human interaction evaluation program at Cinder Lake, Arizona. The power system consisted of a photovoltaic array/battery system. It is capable of providing 1 kW of electrical power. The system outputs were 48 V DC, 110 V AC, and 220 V AC. A cable reel with 200 m of power cable was used to provide power from the trailer to a remote location. The cable reel was installed on a small trailer. The reel was powered to provide low to no tension deployment of the cable. The cable was connected to the 220 V AC output of the power system trailer. The power was then converted back to 110 V AC on the cable deployment trailer for use at the remote site. The Scout lunar rover demonstration vehicle was used to tow the cable trailer and deploy the power cable. This deployment was performed under a number of operational scenarios, manned operation, remote operation and tele-robotically. Once deployed, the cable was used to provide power, from the power system trailer, to run various operational tasks at the remote location.

  13. BEHAVIOR OF ELASTIC TOWING CABLES IN SHEAR CURRENTS

    Institute of Scientific and Technical Information of China (English)

    HOU Guo-xiang; LI Hong-bin; ZHANG Sheng-jun; YANG Yun-tao; XU Shi-hua; XIE Wei

    2005-01-01

    The formulation and solution of governing equations that can be used to analyse the three-dimensional behaviour of elastic towing cables subjected to arbitrary sheared currents were presented in this paper. The elastic cable geometry was described in terms of two angles, elevation and azimuth, which are related to Cartesian co-ordinates by geometry compatibility relations. These relations were combined with the cable equilibrium equations to obtain a system of non-linear differential equations. In the end, results for cable tension, angles, geometry and elongation are presented for example cases.

  14. The Impact of Cable Television Services on the Use of Competing Media

    Science.gov (United States)

    Kaplan, Stuart J.

    1978-01-01

    This study suggests that cable television services currently available on high capacity cable systems receive frequent use and have considerable impact on the subscriber's use of competing media. (Author/STS)

  15. A new approach to underground cable performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Al-Saud, M.S.; El-Kady, M.A.; Findlay, R.D. [Department of Electrical and Computer Engineering, McMaster University, Hamilton, Ontario L8S 4K1 (Canada)

    2008-05-15

    This paper presents a new approach to thermal field sensitivities and ampacity computations of underground power cables using a proposed algorithm of perturbed finite-element analysis. The new approach involves the use of derived sensitivity coefficients associated with various cable parameters of interest, and use these coefficients to achieve optimal cable performance. The proposed model provides a quick methodology, based on the finite-element model, to assess the cable thermal performance subject to variations in the cable thermal circuit parameters. The developed algorithm was applied to various practical cable systems. The effect of multilayered thermal conductivities and boundary parameters variations on the actual cable system ampacity was investigated using the proposed methodology. A comparison was made of the obtained results with the conventional finite-element approach in order to show the applicability and usefulness of the developed methodology. Our objective was to assess the effects of operating parameter variations in a straightforward manner, without repeating the thermal field analysis for each parameter change. The thermal field of an underground power cable sample directly buried in the soil was measured in the laboratory using a developed full-size experimental setup. The investigations involve all parts of the thermal circuit parameters representing cable composition, surrounding soil and boundary phenomena. The experimental setup was used to validate the simulation model by comparing the simulation results with the real laboratory measurements. Such experimental verification confirmed the accuracy of the new introduced finite-element sensitivity methodology. (author)

  16. US8,994,532 "Data Center Equipment Location and Monitoring System"

    DEFF Research Database (Denmark)

    2014-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...

  17. A model for the evaluation of heat loss from underground cables in non-uniform soil to optimize the system design

    Directory of Open Access Journals (Sweden)

    Salata F.

    2015-01-01

    Full Text Available With the proliferation of technologies and underground systems, analysis of thermal fields in soil has become a topic of great interest in the developing technology of buried structures. In this work, we have investigated the steady state temperature field (from linear heat sources - buried cable - in a different type of soil and excavation geometry. In a laboratory, a physical model was built on scale, which reproduces an "undisturbed" area containing a linear thermal source. This scale model was produced for experimental activity. A measuring chain was made to analyze the thermal field in various types of soils, by varying the electrical current through the line source. The physical model was recreated using a finite volume calculation software. Analysis of the different field system configurations were completed and we have studied a model for the improvement of the design method.

  18. Method and system for capturing hydrocarbons from a leaking oilwell at a predetermined seabed location

    NARCIS (Netherlands)

    Van Nauta Lemke, A.H.A.; Willemse, C.A.

    2013-01-01

    Method and system for capturing hydrocarbons from a leaking oilwell at a predetermined seabed location, in which the steps are applied of: a. deploying a dome near the predetermined seabed location; b. moving the dome to the predetermined seabed location; c. capturing the hydrocarbons from the leaki

  19. Baseline System Costs for 50.0 MW Enhanced Geothermal System -- A Function of: Working Fluid, Technology, and Location, Location, Location

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Paul [Gas Equipment Engineering Corp., Milford, CT (United States); Selman, Nancy [Gas Equipment Engineering Corp., Milford, CT (United States); Volpe, Anthony Della [Gas Equipment Engineering Corp., Milford, CT (United States); Moss, Deborah [Gas Equipment Engineering Corp., Milford, CT (United States); Mobley, Rick [Plasma Energy Services, LLC, Putnam, CT (United States); Dickey, Halley [Turbine Air Systems, Houston, TX (United States); Unruh, Jeffery [Fugro NV/Wm. Lettis & Associates, Houston, TX (United States); Hitchcock, Chris [Fugro NV/Wm. Lettis & Associates, Houston, TX (United States); Tanguay, Jasmine [Conservation Law Foundation/CLF Ventures, Boston, MA (United States); Larsen, Walker [Conservation Law Foundation/CLF Ventures, Boston, MA (United States); Sanyal, Sabir [GeothermEx, Inc., San Pablo, CA (United States); Butler, Steven [GeothermEx, Inc., San Pablo, CA (United States); Stacey, Robert [GeothermEx, Inc., San Pablo, CA (United States); Robertson-Tait, Ann [GeothermEx, Inc., San Pablo, CA (United States); Pruess, Karsten [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gutoski, Greg [Fairbanks Morse Engines (FME), Beloit, WI (United States); Fay, Jamie M. [Fort Point Associates, Boston, MA (United States); Stitzer, John T. [Fort Point Associates, Boston, MA (United States); Oglesby, Ken [Impact Technologies LLC, Tulsa, OK (United States)

    2012-04-30

    Substantial unexploited opportunity exists for the US, and the world, in Enhanced Geothermal Systems (EGS). As a result of US DOE investment, new drilling technology, new power generation equipment and cycles enable meaningful power production, in a compact and modular fashion; at lower and lower top side EGS working fluid temperatures and in a broader range of geologies and geographies. This cost analysis effort supports the expansion of Enhanced Geothermal Systems (EGS), furthering DOE strategic themes of energy security and sub goal of energy diversity; reducing the Nation's dependence on foreign oil while improving the environment.

  20. Cable-Dispensing Cart

    Science.gov (United States)

    Bredberg, Alan S.

    2003-01-01

    A versatile cable-dispensing cart can support as many as a few dozen reels of cable, wire, and/or rope. The cart can be adjusted to accommodate reels of various diameters and widths, and can be expanded, contracted, or otherwise reconfigured by use of easily installable and removable parts that can be carried onboard. Among these parts are dispensing rods and a cable guide that enables dispensing of cables without affecting the direction of pull. Individual reels can be mounted on or removed from the cart without affecting the other reels: this feature facilitates the replacement or reuse of partially depleted reels, thereby helping to reduce waste. Multiple cables, wires, or ropes can be dispensed simultaneously. For maneuverability, the cart is mounted on three wheels. Once it has been positioned, the cart is supported by rubber mounts for stability and for prevention of sliding or rolling during dispensing operations. The stability and safety of the cart are enhanced by a low-center-of-gravity design. The cart can readily be disassembled into smaller units for storage or shipping, then reassembled in the desired configuration at a job site.

  1. The Research of Cable Network EPON ONU Automatic Authentication System%有线电视网络EPON ONU自动认证系统的研究

    Institute of Scientific and Technical Information of China (English)

    郭浩; 张华锋; 赵晗笑

    2016-01-01

    在政策激励、宽带提速及光进铜退趋势的推动下,高速数据、超高清点播及OTT等新业务的出现,有线电视网络运营商逐渐开始采用FTTH技术建设双向网络。本文结合原有HFC网络认证系统及光纤到户EPON系统的特点,提出了一种ONU自动认证系统,充分利用已有的LDAP认证服务器及EPON网管,实现了ONU在OLTPON端口的自动认证及ONU业务的自动认证,保障了光纤到户网络业务的快速开通。%With the promotion of policy incentives, broadband speeding-up , fiber-instead-cable operation, some new business like high-speed data service, high-definition VOD and OTT appeared. Cable TV network oper-ators are beginning to adopt FTTH to construct the access networks. According to the characters of HFC authen-tication system and the FTTH EPON system, we propose a system of ONU Automatic authentication, taking full advantage of the LADP and the network management of EPON system, achieving the functions of ONU Automatic authentication in the port of OLT, guaranteeing the FTTH network business developed effectively.

  2. Recent progress of HTS cable project

    Science.gov (United States)

    Masuda, T.; Yumura, H.; Watanabe, M.

    2008-09-01

    A lot of developments of HTS wires and their applications have been conducted since the discovery of HTS materials in the world. It has been recently reported that critical current of BSCCO wires improved to more than 200 A at 77 K and a large amount of wire was provided with high quality as industrial products. This improvement can be expected to accelerate the commercialization of HTS applications such as an HTS cable, HTS motor and so on. As the proofs of such trends, Sumitomo Electric constructed two HTS cable systems and started their operations in the USA and Korea last year. One of them is the HTS cable in Albany, NY, which has a capacity of 34.5 kV and 800 A and 350 m in length. It has been operated in a real grid without any trouble for 9 months. The other is the HTS cable in Korea, which has a capacity of 22.9 kV and 1250 A and 100 m in length. Its operation also started in the KEPCO testing yard last year. These results demonstrate reliance and stability of its operation. Recently, a new national project of an HTS cable has just started in Japan to demonstrate the operation in a real grid and study the system operations including a monitoring method, an alarm system, a maintenance method, etc. This paper reports the results of Albany and Korea projects and an outline of the new project.

  3. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  4. Semiannual report for the period April 1 to September 30, 1978 of work on: (1) superconducting power transmission system development; (2) cable insulation development. Power Transmission Project technical note No. 83

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-07

    Progress in the development, fabrication and testing of superconductors for HVAC power transmission systems is reported. Information is included on the materials evaluation of superconducting alloys, production of tapes from these alloys, principally Nb/sub 3/Sn cable insulation requirements and development, and the cryogenic equipment used in this research program. (LCL)

  5. The Danish Superconducting Cable Project

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1997-01-01

    The design and construction of a superconducting cable is described. The cable has a room temperature dielectric design with the cryostat placed inside the electrical insulation.BSCCO 2223 superconducting tapes wound in helix form around a former are used as the cable conductor. Results from...

  6. An Integrated Learning Management System for Location-Based Mobile Learning

    Science.gov (United States)

    Sailer, Christian; Kiefer, Peter; Raubal, Martin

    2015-01-01

    This paper discusses the relevance and challenges of a location-based learning platform that supports mobile learning in education. We present the design of an integrated management system for location-based mobile learning. Independent of the taught subject, the objective of the system is an easy-to-understand user interface for both - teachers…

  7. Outdoor Education Support System with Location Awareness Using RFID and Symbology Tags

    Science.gov (United States)

    Osawa, Noritaka; Noda, Katsuji; Tsukagoshi, Satoru; Noma, Yutaka; Ando, Akikazu; Shibuya, Tomoharu; Kondo, Kimio

    2007-01-01

    A support system for outdoor learning using exploratory observation was developed. The system uses radio frequency identification (RFID) tags and two-dimensional (2D) symbology tags to locate positions on a horticultural farm and its surrounding forests. Students were able to get a location-dependent description and an educational hint for…

  8. Comparison of various procedures for progressive collapse analysis of cable-stayed bridges

    Institute of Scientific and Technical Information of China (English)

    Jian-guo CAI; Yi-xiang XU; Li-ping ZHUANG; Jian FENG; Jin ZHANG

    2012-01-01

    Alternate path (AP) method is the most widely used method for the progressive collapse analysis,and its application in frame structures has been well proved.However,the application of AP method for other structures,especially for cable-stayed structures,should be further developed.The four analytical procedures,i.e.,linear static,nonlinear static,linear dynamic,and nonlinear dynamic were firstly improved by taking into account the initial state.Then a cable-stayed structure was studied using the four improved methods.Furthermore,the losses of both one cable and two cables were discussed.The results show that for static and dynamic analyses of the cable-stayed bridges,there is large difference between the results obtained from simulations starting with either a deformed or a nondeformed configuration at the time of cable loss.The static results are conservative in the vicinity of the ruptured cable,but the dynamic effect of the cable loss in the area farther away from the loss-cable cannot be considered.Moreover,the dynamic amplification factor of 2.0 is found to be a good estimate for static analysis procedures,since linear static and linear dynamic procedures yield approximately the same maximum vertical deflection.The results of the comprehensive evaluation of the cable failure show that the tread of the progressive failure of the cable-stayed bridges decreases when the location of the failed cables is closer to the pylon.

  9. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.607 Breaking trailing cable and power cable connections. Trailing cable and power cable connections...

  10. On the Optimal Location of Sensors for Parametric Identification of Linear Systems

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Brincker, Rune

    1994-01-01

    An outline of the field of optimal location of sensors for parametric identification of linear structural systems is presented. There are few papers devoted to the case of optimal location of sensors in which the measurements are modeled by a random field with non-trivial covariance function...... with variations in the number and location of sensors. Further, the influence of noise on the optimal location of the sensors is investigated. It is found that the optimal locations of sensors seem to become less sensitive to e.g. the noise-to-signal ratio within increasing number of sensors....

  11. Cable Aerodynamic Control

    DEFF Research Database (Denmark)

    Kleissl, Kenneth

    to a categorization of the different control technics together with an identification of two key mechanisms for reduction of the design drag force. During this project extensive experimental work examining the aerodynamics of the currently used cable surface modifications together with new innovative proposals have...

  12. Comparison of cable ageing

    Science.gov (United States)

    Plaček, Vít; Kohout, Tomáš

    2010-03-01

    Two cable types, which currently are used in nuclear power plants (NPP) and which are composed by jacket/insulation materials, i.e. PVC/PVC and PVC/PE, were exposed to accelerated ageing conditions, in order to simulate their behavior after 10 years in service. The cables were aged under two different test conditions: With relatively high accelerating ageing speed:Radiation ageing was carried out at room temperature at a dose rate of 2900 Gy/h, followed by thermal ageing at 100 °C. This accelerated ageing condition was fairly fast, but still in compliance with the standards. With moderate ageing speed:The radiation and thermal ageing was performed simultaneously (superimposed) at a dose rate of 2.7-3.7Gy/h and a temperature of 68-70 °C. Such a test condition seems to be very close to the radiation and temperature impact onto the cables in the real NPP service. Finally, mechanical properties were measured to characterize the ageing status of the cables. The purpose of this study was to compare degradation effects, derived from both ageing methods, and to demonstrate that results obtained from high values of accelerating parameters and from fast ageing simulation can be very different from reality. The observed results corroborated this assumption.

  13. Lightweight Electric Power Cable.

    Science.gov (United States)

    1982-09-01

    8I~ .4 111 162 MICROCi Pi RL’ LUHION TESI CHARI "LIGHTWEIGHT ELECTRIC POWER CABLE" FINAL TECHNICAL REPORT SEPTEMBER 30, 1981 to SEPTEMBER 30, 1982... Vulcanized by heat to crosslink. TPE (Thermoplastic Elastomer) - Polymers having elastomeric proper- ties. Used as thermoplastics - melt formed by

  14. 30 CFR 77.804 - High-voltage trailing cables; minimum design requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; minimum design... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.804 High-voltage trailing cables; minimum design requirements. (a) High-voltage trailing cables used in resistance grounded systems shall...

  15. On-site Testing and PD Diagnosis of High Voltage Power Cables

    NARCIS (Netherlands)

    Gulski, E.; Cichecki, P.; Wester, F.; Smit, J.J.; Bodega, R.; Hermans, T.J.W.H.; Seitz, P.P.; Quak, B.; De Vries, F.

    2008-01-01

    In addition to after-laying of new-installed high voltage (HV) power cables the use of on-site non-destructive on-site testing and diagnosis of service aged power cables is becoming an important issue to determine the actual condition of the cable systems and to determine the future performances. In

  16. Development of (RE)BCO cables for HTS power transmission lines

    Science.gov (United States)

    Mukoyama, S.; Yagi, M.; Masuda, T.; Amemiya, N.; Ishiyama, A.; Kashima, N.; Nagaya, S.; Aoki, Y.; Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y.

    2009-10-01

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I c and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  17. Development of (RE)BCO cables for HTS power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Mukoyama, S., E-mail: mukoyama@ch.furukawa.co.j [Furukawa Electric Co. Ltd., Ichihara 290-8555 (Japan); Yagi, M. [Furukawa Electric Co. Ltd., Ichihara 290-8555 (Japan); Masuda, T. [Sumitomo Electric Industries, Ltd., Osaka 554-0024 (Japan); Amemiya, N. [Kyoto University, Kyoto 615-8510 (Japan); Ishiyama, A. [Waseda University, Tokyo 169-8555 (Japan); Kashima, N.; Nagaya, S. [Chubu Electric Power Co. Inc., Nagoya 459-8522 (Japan); Aoki, Y. [Showa Cable System Co. Ltd., Sagamihara 229-1133 (Japan); Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y. [Superconductivity Research Laboratory, Tokyo 135-0062 (Japan)

    2009-10-15

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I{sub c} and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  18. Electric Propulsion Cables For Milli-Newton Thrusters

    Science.gov (United States)

    Jakob, Manfred; Bertrand, Arnaud; El-Idrissi, Mohamed; Schaper, Wolfgang, , Dr.

    2011-10-01

    AXON' Kabel GmbH, is developing and manufacturing cables and connectors up to complete interconnect systems for all types of applications needed in Space. As a request from ESA, AXON has developed a new generation of cables suitable for current and future applications to feed electric propulsion thruster systems in spacecraft with electric power. Under this project the main objectives were to find and select materials for the composition to produce a cable withstanding quite strongrequirements for operating temperature, radiation resistance, high voltage application and in variants to various current ratings (A); the cable construction will also include ESD immunisation. The paper will summarise the specification achieved and will give an overview on the test results with the prototype cables.

  19. SUPPORTING SALESPERSONS' CRM EFFORTS THROUGH LOCATION-BASED MOBILE SUPPORT SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    Chihab BENMOUSSA

    2005-01-01

    This paper aims at assessing how location-based mobile support systems can support salespersons' CRM efforts when they are operating within a highly mobile work environment. After briefly discussing the state-of-the-art issues associated with mobile location technologies, the paper conceptualizes key dimensions for location-based mobile support systems. The paper then discusses the dual role of salespersons in CRM. A fourth section suggests a categorization of salespersons'CRM tasks based on both properties of location-based mobile support and the areas of salespersons'CRM-related tasks that may be affected by mobile location technologies. Finally, the paper suggests potential mobile location services and applications that can help salespersons perform effectively their everyday CRM tasks and link such applications to the determinant of salespersons' performance. The paper concludes with a discussion of some critical issues and suggests areas for further research.

  20. Future services for cable television networks

    Science.gov (United States)

    Powell, William H.

    1995-11-01

    This paper examines the evolutionary potential of hybrid fiber coaxial systems for new services. It is shown that the cost of building dual (or 'overlay') cable TV and telecom networks is higher than adding telephony to a cable TV network on the hybrid fiber coax principle. It is shown that other services including Ethernet access to the Internet can also be added at low incremental cost. The potential of modems carrying ATM traffic to carry an even wider range of services is also considered.

  1. Dynamic Loadability of Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt

    This thesis is the product of three years research within the field of dynamic loadability of cable based transmission grids. The report contains a summary of the three year PhD project which has been conducted in a collaboration between the Danish Transmission System Operator (TSO), Energinet...... supervised 2 master projects, as well as 5 special courses at DTU. Furthermore I created and taught a cable course, with approximately 25 students, throughout 13 weeks during the spring of 2011. The PhD project has until now contributed with 3 journal papers and 4 conference papers. Selected papers can...

  2. XLPE电缆局部放电在线监测系统的研制%The Development of an On-line Monitoring System Adopting Partial D ischarge of XLPE Cables

    Institute of Scientific and Technical Information of China (English)

    陈瑞龙; 钱勇; 叶海峰; 董越; 江秀臣

    2014-01-01

    局部放电检测是判断XLPE 电力电缆绝缘状况的重要手段。设计并开发了一套用于中压XLPE 电缆的局部放电在线监测系统,详细阐述了其工作原理、硬件组成、软件设计及实现方案。通过监测XLPE 电缆屏蔽层接地线中的高频电流信号,来分析评估XLPE 电缆的绝缘状况。现场运行结果显示,系统稳定可靠,能满足整个变电站中压XLPE 电缆绝缘监测的需要。%Partial discharge detection is an important means to judge the situation of XLPE power cables insulation.This paper designs and develops a partial discharge online monitoring system used for the medium-voltage XLPE cable,and describes details on its working principle,hardware composition,software design and implementation schemes.By monitoring the high-frequency current signal in the grounding line of the shielded layers of the XLPE cables,this system analyzes and assesses the insulation of these cables.The result of on-site operation indicates that it is a stable,reliable system which can meet the requirement on insulation monitoring of medium-voltage XLPE cables of the whole sub-station.

  3. Wireless Location Determination for Mobile Objects Based on GSM in Intelligent Transportation Systems

    Institute of Scientific and Technical Information of China (English)

    徐志扬; 施鹏飞

    2003-01-01

    The mobile object (MO) location determination technologies which can be used in intelligent transportation system (ITS) are studied in this paper. The principles and characteristics of wireless location determination technologies are introduced and the characteristics of GSM useful for location determination are also summarized. An experimental positioning system based on GSM is proposed, and the architecture is described. TOA method based on GSM signals and TDOA method are used in the experimental system. Moreover, the methods are simulated. The performance of the positioning methods is assessed in the simulation environment, and the accuracy for 67% mobile stations (MS) is 70m in urban areas.

  4. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  5. Cable Overheating Risk Warning Method Based on Impedance Parameter Estimation in Distribution Network

    Science.gov (United States)

    Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao

    2017-05-01

    Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.

  6. Extracting modal parameters of a cable on shaky motion pictures

    Science.gov (United States)

    Hwa Kim, Byeong

    2014-12-01

    A set of modal parameters of a cable are extracted from a motion picture captured by a digital camera operated with shaking hands. It is difficult to identify the center of the targets attached to the cable surface from the blurred motion image of the cable, because of the high-speed motion of the cable, low sampling frequency of the camera, and the effect of shaking hands on the motion pictures. This paper proposes a multi-template matching algorithm to solve these difficulties. In addition, a sensitivity-based system identification algorithm is proposed for extracting the natural frequencies and the damping ratios from ambient cable vibration data. Three sets of vibration tests are performed to examine the validity of the proposed algorithms. The results show that the proposed approach of using these two algorithms is fairly feasible for extracting modal parameters from severely blurred motion pictures.

  7. Field measurement of wind pressure and wind-induced vibration of large-span spatial cable-truss system under strong wind or typhoon

    Directory of Open Access Journals (Sweden)

    ZHANG Zhihong

    2013-10-01

    Full Text Available In order to ensure wind-resistance safety of large-span pre-stressed flexible system in southeast coast area of China,and to prepare something for revising of current codes of practice or technical standards,the present paper conducts field measurement of wind pressure and wind-induced vibration of a practical and typical large-span spatial cable-truss system-lunar stadium in Yueqing city.Wind loading and wind effects on full-scale structure under strong wind or typhoon in real architectural environment can be obtained directly and effectively.Field measurement is the best way to investigate the wind loading property,wind effects,and wind-structure interactions of large-span flexible system.Measured data will be highly valuable for scientific research and practical design.On the other hand,it also provides the basis of wind-resistance safety design of this kind of tension structures.If any creative development,it would dramatically improve the research level of large-span pre-stressed flexible system in our country.

  8. Nonlinear Dynamic Reliability of Coupled Stay Cables and Bridge Tower

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Nonlinear vibration can cause serious problems in long span cable-stayed bridges. When the internal resonance threshold is reached between the excitation frequency and natural frequency,large amplitudes occur in the cable. Based on the current situation of lacking corresponding constraint criteria, a model was presented for analyzing the dynamic reliability of coupling oscillation between the cable and tower in a cable-stayed bridge. First of all, in the case of cable sag, the d'Alembert principle is applied to studying the nonlinear dynamic behavior of the structure, and resonance failure interval of parametric oscillation is calculated accordingly. Then the dynamic reliability model is set up using the JC method. An application of this model has been developed for the preliminary design of one cable-stayed bridge located on Hai River in Tianjin, and time histories analysis as well as reliability indexes have been obtained. When frequency ratio between the cable and tower is approaching 1∶2, the reliability index is 0.98, indicating high failure probability. And this is consistent with theoretical derivation and experimental results in reference. This model, which is capable of computing the reliability index of resonance failure, provides theoretical basis for the establishment of corresponding rule.

  9. Passive location using CDMA mobile communication system based on repeater equipment

    Institute of Scientific and Technical Information of China (English)

    TIAN Zeng-shan; ZHOU Fei; ZHANG Tian-qi

    2008-01-01

    To overcome the drawback of a short operation range and low-resolution of a passive location system using a civil communication signal, the new idea that utilizes code division multiple access (CDMA) signal and repeater is disposed off. First, the CDMA passive location model and observation function are given, and the error source and error range are analyzed. Subsequently, the CDMA passive location algorithm in a repeater environment is described and simulated. The simulation result shows that the algorithm can provide the location value with high accuracy.

  10. Method to improve superconductor cable

    Science.gov (United States)

    Borden, A.R.

    1984-03-08

    A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

  11. Test Results For a 25-m Prototype Fault Current Limiting HTS Cable for Project Hydra

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Christopher M [ORNL; Duckworth, Robert C [ORNL; Demko, Jonathan A [ORNL; Ellis, Alvin R [ORNL; Gouge, Michael J [ORNL; James, David Randy [ORNL; Tuncer, Enis [ORNL

    2010-01-01

    The Oak Ridge National Laboratory (ORNL) has tested a 25-m long prototype High Temperature Superconducting (HTS) cable with inherent Fault-Current Limiting (FCL) capability at its recently upgraded HTS cable test facility in Oak Ridge, TN. The HTS-FCL cable and terminations were designed and fabricated by Ultera, which is a joint venture of Southwire and nkt cables with FCL features and HTS wire provided by American Superconductor Corporation. The overall project is sponsored by the U.S. Department of Homeland Security. The ultimate goal of the 25-m HTS-FCL cable test program was to verify the design and ensure the operational integrity for the eventual installation of a ~ 200-m fully functional HTS-FCL cable in the Consolidated Edison electric grid located in downtown New York City. The 25-m HTS-FCL cable consisted of a three-phase (3- ) Triax design with a cold dielectric between the phases. The HTS-FCL cable had an operational voltage of 13.8 kV phase-to-phase and an operating current of 4000 Arms per phase, which is the highest operating current to date of any HTS cable. The 25-m HTS-FCL cable was subjected to a series of cryogenic and electrical tests. Test results from the 25-m HTS-FCL cable are presented and discussed.

  12. Design and implementation of urban logistics distribution center location optimization system

    Directory of Open Access Journals (Sweden)

    Peng GUO

    2017-02-01

    Full Text Available In order to improve the efficiency of urban logistics distribution center location selection, and to overcome the shortcomings of the traditional method based on human aided calculation, the online map is used to obtain the path distance information. Considering the practical construction and operation situation of the logistics distribution center, the cost related impact factors are determined and the location optimization frame is described. Then the mathematical formulation is proposed for minimizing the total cost, and the genetic algorithm based on integer code is designed to solve the problem under consideration. The corresponding system is implemented by C# language. The system is tested based on the practical data, and the computational results demonstrate that the proposed system can automatically obtain the distance information between various nodes and perform the location optimization. Finally the optimal feasible location scheme is delivered by the proposed system.

  13. Implant overdenture and Locator system in edentulous patient with severely resorbed mandible - a case report.

    Science.gov (United States)

    Ionescu, Camelia; Gălbinaşu, Bogdan Mihai; Manolea, Horia; Pătraşcu, Ion

    2014-01-01

    Clinical studies have revealed that the main objective of implants in the edentulous jaw is to provide support for fixed prostheses or to stabilize complete dentures. Various attachment systems were developed for universal use in partially and completely edentulous patients such as clasps, cone-shape telescope copings, magnets, bar systems, locators. The aim of this case report is to present the Locator attachment that does not use the splinting of implants. Four implants were placed in the foraminal region and the Locator attachment system was used to connect overdentures to mandibular dental implants. The results proved that the Locator attachment system offers the possibility to obtain a higher retention and an improved stability for overdentures in edentulous patients with a severely resorbed mandible and lack of vertical space between the arches.

  14. EIGENFREQUENCY ANALYSIS OF CABLE STRUCTURES WITH INCLINED CABLES

    Institute of Scientific and Technical Information of China (English)

    William Paulsen; Greg Slayton

    2006-01-01

    The approximate eigenfrequencies for the in-plane vibrations of a cable structure consisting of inclined cables, together with point masses at various points were computed. It was discovered that the classical transfer matrix method was inadequate for this task, and hence the larger exterior matrices were used to determine the eigenfrequency equation. Then predictions of the dynamics of the general cable structure based on the asymptotic estimates of the exterior matrices were made.

  15. A new monitoring method of cable tension of cable-stayed bridge-fiber Bragg grating method

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xu-she; DU Yan-liang; NING Chen-xiao

    2005-01-01

    A new on-line monitoring method based on fiber Bragg grating (FBG) for cable tension of cable-stayed bridge was introduced. The major structure of sensing head using in the test of cable tension is elastic annular. The FBG is attached inflexibility to the exterior surface of annulus and form straight-through sensing head. Sensing headis installed between the anchor device and stow-board of funiculus holes of the cable-stayed bridge. Accompany with the change of the outside pressure, the Bragg center reflective wavelength of optical fiber grating changed correspondingly. According to this characteristic, through demodulating the△λ, the value of the cable tension can be determined. The experiment results and the theory indicate that the test system has simple structure, good stability and linear,wide response capacity, and has no special request for tester, The measurement method for the test of ca ble tension is practical and effective.

  16. Automated correction of room location errors in anesthesia information management systems.

    Science.gov (United States)

    Epstein, Richard H; Dexter, Franklin; Piotrowski, Elizabeth

    2008-09-01

    Anesthesia information management systems (AIMS) and operating room information management systems (ORIMS) are both used in operating rooms (OR). Anesthesia providers use AIMS to document their care in near real-time, including milestone events, and these systems automatically record vital signs from patient monitors. Circulating nurses use ORIMS primarily to document procedural information. Because of automatic documentation, AIMS would be ideal platforms for OR managerial decision support if the correct locations of cases in progress were known accurately. Trust is diminished if recommendations are poor. We compiled room location error rates from prior analyses of ORIMS data. Data from 24 consecutive 4-wk periods (45,459 cases) were analyzed from one hospital where both ORIMS and AIMS data were available. The actual location of cases was inferred from the physical location of the workstation recording the majority of pulse oximetry saturations. These were compared to the listed location in the AIMS and the final corrected location in the ORIMS. The scheduled and final ORIMS locations were compared to determine how often location changes were updated before the start of anesthesia. The location of cases was inferred in near real-time by using the identifier of the AIMS workstation transmitting pulse oximetry saturated electrocardiogram heart rate, and end-tidal CO(2) partial pressures. Location error rates ranged from 0% to 7.5% at 42 hospitals. The error rate at the studied hospital was just 0.4%, showing that the hospital was suitable for investigation. The 0.4% error rate was based on cases listed as overlapping in the same OR, and thus under-estimated the actual error rate in the ORIMS (1.0%). With education, there was a decrease in the moved cases in the ORIMS whose location was not changed before the start of anesthesia (9.3%-2.0%, P < 10(-5)). Despite the significant improvement (P < 10(-5)) in the error rate between the AIMS listed and actual locations

  17. A study for high accuracy real-time 3D ultrasonic location system.

    Science.gov (United States)

    Zhou, Ping; Ha, Zhang; Zhou, Kangyuan

    2006-12-22

    We discussed a high accuracy real-time 3D ultrasonic location system in this article. The signal received was sampled after it passed the TGC and the logarithmic amplifier. Inside the DSP, we used the dynamic threshold tracing technique to improve the accuracy. The result was processed with Weighted Arithmetic Average. By testing the 40 kHz 3D location system, we have arrived at the accuracy of 1 cm.

  18. Recommendation System for Product Using User Interest, Social Circle and Location of User

    Directory of Open Access Journals (Sweden)

    Himgauri D. Ambulkar , Apashabi Pathan

    2016-07-01

    Full Text Available Recommendation System (RS is used to discover users interested items. The present testimonial framework is not efficient as desire. It has to require enhancement in framework for current and future necessities to getting best results for recommendation qualities. This paper combines four factors such as users interest, personal interest similarity, interpersonal impact and user’s location information. In propose system we add user location in dataset also use PCC similarity method which reduce the RMSE and MAE errors

  19. An Experimental Study on Non-Compression X-Bracing Systems Using Carbon Fiber Composite Cable for Seismic Strengthening of RC Buildings

    Directory of Open Access Journals (Sweden)

    Kang Seok Lee

    2015-09-01

    Full Text Available Cross-bracing (X-bracing is one of the most popular methods of seismic retrofitting, and has been shown to significantly increase the structural stiffness and strength of buildings. Conventional steel X-bracing methods typically exhibit brittle failure at the connection between the brace and the building, or buckling failure of the braces. This study investigated the structural properties of a new type of non-compression X-bracing system using carbon fiber composite cable (CFCC. This non-compression X-bracing system uses CFCC bracing and bolt connections between structural members and the terminal fixer of the CFCC, instead of conventional steel bracing. The aim is to overcome the brittle and buckling failures that can occur at the connection and bracings with conventional steel X-bracing methods. We carried out cyclic loading tests, and the maximum load carrying capacity and deformation were investigated, as well as hysteresis in the lateral load–drift relations. The test results revealed that the CFCC X-bracing system installed in reinforced concrete frames enhanced the strength markedly, and buckling failure of the bracing was not observed.

  20. On the control performance of motors driven by long cables for remote handling at ITER

    Energy Technology Data Exchange (ETDEWEB)

    Sol, Enrique del, E-mail: enrique.delsol@oxfordtechnologies.co.uk [Oxford Technologies Ltd., 7 Nuffield Way, Abingdon OX141RL (United Kingdom); Meek, Richard [Oxford Technologies Ltd., 7 Nuffield Way, Abingdon OX141RL (United Kingdom); Ruiz Morales, Emilio; Vitelli, Ricardo; Esqué, Salvador [Fusion for Energy, Josep Pla, 2, Barcelona 08019 (Spain)

    2016-06-15

    Highlights: • We show the dangerous effects of reflections on the actuator’s system. • We prove how to solve the reflections issue with a commercial LC filter. • We study the filter influence for short cables on two control modes. • We show the filter performance under a real remote handling operation. • We study the excellent performance of the filter for different cable lengths. - Abstract: Pulse Width Modulation (PWM) is nowadays the most used method for controlling a servo-motor. When combining PWM with motors and long cables, such as the ones that will be found at ITER, the standing waves originated are potentially very harmful for both actuator’s life span and control performance. Several methods have been investigated to cope with this issue, such as the use of chokes, filters, snubbers or active modification of the PWM signal. Of all possible locations where an electrical servo-motor could be used at ITER, the most critical scenario arises when mounting a low power motor, with a low gear ratio, in a dexterous manipulator for bilateral teleoperation. In those circumstances cable lengths of more than 150 m are expected between manipulator and control cubicle. In this paper, the effects of long cables in the system safety are analysed on a custom made test bench. The most common solutions to cope with this issue are analysed and a commercial LC filter is selected for further experimentation. An extensive set of experiments are carried out in order to validate the proposed solution for being used on remote handling equipment at ITER.