WorldWideScience

Sample records for c-urea breath test

  1. ( sup 14 C)urea breath test for diagnosis of Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Ormand, J.E.; Talley, N.J.; Carpenter, H.A.; Shorter, R.G.; Conley, C.R.; Wilson, W.R.; DiMagno, E.P.; Zinsmeister, A.R.; Phillips, S.F. (Mayo Clinic, Rochester, MN (USA))

    1990-07-01

    H. pylori is a potent urease producer, a characteristic that has been exploited in the development of the (14C)- and (13C)urea breath tests. The prevalence of H. pylori infection also is known to increase with advancing age; however, the individual patient's age has not routinely been considered when interpreting urea breath test results. The aim of this study was to validate a short, age-adjusted (14C)urea breath test for use in diagnosing H. pylori infections. Forty-one subjects (28 volunteers, 13 patients) underwent esophagogastroduodenoscopy with biopsies. Subjects were defined as being H. pylori-positive if histology or culture was positive. In addition, all subjects completed a 120-min (14C)urea breath test. A logistic regression analysis adjusting for age was used to estimate the probability of H. pylori positivity as a function of the 14C values generated. Sixteen subjects were H. pylori-positive, and 25 were H. pylori-negative. The 14C values generated between 15 and 80 min were found to be equally predictive in identifying H. pylori-positive subjects. Advancing age was associated with a higher probability of H. pylori-positivity. By taking advantage of the statistical probabilities, older patients could be accurately diagnosed with H. pylori at lower 14C values. We found that (14C)urea breath test to be both a sensitive and specific test that can be abbreviated to a 30-min examination (total test time). Moreover, our mathematical model indicates that a patient's age should be considered in order to optimize interpretation of the (14C)urea breath test, although further observations are needed to confirm this model.

  2. sup 14 C-urea breath test for the detection of Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.; Jalali, S.; Rshid, F.A.; Bowen, B.M.; Goldie, J.; Goodacre, R.L.; Riddell, R.H.; Hunt, R.H. (McMaster Univ., Hamilton, Ontario (Canada))

    1990-04-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a {sup 14}C-urea breath test which uses 5 microCi {sup 14}C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positive predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled {sup 14}CO{sub 2} which correlated with histological improvement in gastritis. The {sup 14}C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture.

  3. Validation of {sup 14} C-urea breath test for diagnosis of Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Mattar, Rejane; Silva, Fernando Marcuz; Alexandrino, Ana Maria; Laudanna, Antonio Atilio [Sao Paulo Univ., SP (Brazil). Hospital das Clinicas. Dept. de Gastroenterologia]. E-mail: shiroineko@uol.com.br

    1999-02-01

    The aim of this study was to validate the {sup 14} C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H pylori IgG entered the study. Fasting patients drank 5 uCi of {sup 14} C-urea in 20 ml of water. Breath samples were collected at O, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p < 0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). {sup 14} C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection. (author)

  4. Does low dose13C-urea breath test maintain a satisfactory accuracy in diagnosing Helicobacter pylori infection?

    Directory of Open Access Journals (Sweden)

    Luiz Gonzaga Vaz Coelho

    2011-06-01

    Full Text Available CONTEXT: The standard doses of 13C-urea in 13C-urea breath test is 75 mg. OBJECTIVE: To assess the diagnostic accuracy of 13C-urea breath test containing 25 mg of 13C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. METHODS: Two hundred seventy adult patients (96 males, 174 females, median age 41 years performed the standard 13C-urea breath test (75 mg 13C-urea and repeated the 13C-urea breath test using only 25 mg of 13C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. RESULTS: One hundred sixty-one (59.6% patients were H. pylori negative and 109 (40.4% were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg 13C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3 at our setting. Therefore, we obtained to 25 mg 13C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9, sensitivity 83.5% (95% CI: 75.4-89.3, specificity 99.4% (95% CI: 96.6-99.9, positive predictive value 98.3% (95% CI: 92.4-99.4, and negative predictive value 93.0% (95% CI: 88.6-96.1. CONCLUSIONS: Low-dose 13C-urea breath test (25 mg 13C-urea does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of 13C-urea in the urea breath test.

  5. Accuracy of the {sup 14} C-urea breath test for the diagnosis of Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Ana Thereza Britto [Bahia Univ., Salvador (Brazil). Faculdade de Medicina; Coelho, Luciano Kowalsky [Faculdade de Medicina de Blumenau, SC (Brazil); Secaf, Marie [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Modena, Jose Luiz Pimenta; Troncon, Luiz Ernesto de Almeida; Oliveira, Ricardo Brandt de [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Medicina

    2002-05-01

    The development of simple, accurate and low-expense techniques for detection of Helicobacter pylori infection has great relevance. The objective was to determine the accuracy of a rapid {sup 14} C-urea breath test (UBT) employing a very simple device for breathed air collection. One hundred and thirty-seven adult patients who underwent upper gastrointestinal endoscopy in the Clinical Hospital. The main measurements were histology for Helicobacter pylori (HP); urease test; urea breath test (UBT). One hundred and fifteen patients were infected by HP (HP +) according to both histology and the urease test, and 22 patients were HP-negative (HP-), according to the same two tests. UBT was capable of discriminating between HP + and HP- in a way that was similar to the combination of urease test and histology. When this combination of results is taken as the 'gold standard' for HP infection, the sensitivity and specificity of UBT are both greater than 90% for a range of cut-off points and breathed air collection times. It was concluded that the rapid UBT employing a simple device for air collection has a high accuracy in determining HP infection. (author)

  6. An optimized 13C-urea breath test for the diagnosis of H pylori infection

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of-H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy.METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2)and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol.RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity,specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively.CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost.

  7. The fate of ingested [sup 14]C-urea in the urea breath test for Helicobacter pylori infection

    Energy Technology Data Exchange (ETDEWEB)

    Munster, D.J.; Chapman, B.A.; Burt, M.J.; Dobbs, B.R.; Allardyce, R.A.; Bagshaw, P.F.; Troughton, W.D.; Cook, H.B. (Christchurch Hospital (New Zealand))

    1993-08-01

    The metabolic fate of the radioactive carbon in the [sup 14]C-urea breath test for Helicobacter pylori was investigated in 18 subjects. After ingestion of labelled urea, breath was sampled for 24 h, and urine was collected for 3 days. Subjects were designated high or low expirers on the basis of their breath counts, and this agreed well with H. pylori serologic analyses. When given 185 or 37 kBq of [sup 14]C-urea, 51% of the label was recovered from the breath of high expirers, and 7% from the breath of low expirers. The mean combined urinary and breath recovery for high expirers was 86%, and for low expirers it was 97%. It is concluded that the long-term retention of [sup 14]C from ingested [sup 14]C-urea is low. The results enable a more accurate estimation to be made of radiation exposure resulting from the [sup 14]C-urea breath test. 16 refs., 3 figs., 2 tabs.

  8. Capsule 13C-urea breath test for the diagnosis of Helicobacter pylori infection

    Institute of Scientific and Technical Information of China (English)

    Nan-Jing Peng; Ping-I Hsu; Kwok-Hung Lai; Ren-Shyan Liu; Shui-Cheng Lee; Daw-Guey Tsay; Ching-Chu Lo; Huei-Hwa Tseng; Wen-Keui Huang; Gin-Ho Lo

    2005-01-01

    AIM: To compare the accuracy of capsule 13C-urea breath test (UBT) with conventional invasive methods for the diagnosis of Helicobacter pylori infection.METHODS: One hundred patients received CLO test,histological examination, culture and 100- or 50-mg capsule UBT for the diagnosis of Hpyloriinfection. Hpylori infection was defined as those with positive culture or positive results from both histology and CLO test.RESULTS: Both the sensitivity and specificity of the 100-mg capsule UBT (n = 50) were 100%. The sensitivity and specificity of the 50-mg capsule UBT (n = 50) were 96.4and 100%, respectively. Taken together, the accuracy of capsule UBT (n=100) was higher than that of CLO test,histology and culture (100% vs 92%, 91% and 89%,respectively; P= 0.035, 0.018 and 0.005, respectively). Our data showed that the optimal timing of sampling for 100-and 50-mg capsule UBT was 15-30 and 6-15 min, respectively.CONCLUSION: Capsule UBT has a higher accuracy compared with biopsy-based tests. It is an ideal method for the diagnosis of Hpyloriinfection.

  9. {sup 13}C-urea breath test analyzed with infrared isotope spectrometry for the diagnosis of Helicobacter pylori; {sup 13}C-urea-pusteproeve som dagnostisk metode ved Helicobacter pylori-infeksjon

    Energy Technology Data Exchange (ETDEWEB)

    Dahlberg, M.; Schoensby, H. [Aker Sykehus, Oslo (Norway)

    1998-10-01

    The authors have evaluated a {sup 13}C-urea breath test for the diagnosis of Helicobacter pylori infection. The {sup 13}C-test was analyzed with isotope-selective non-dispersive infrared spectrometry and compared with a {sup 14}C-urea breath test and the urease test in gastric mucosal biopsies. 46 patients were analyzed with breath tests, 23 patients were negative and 22 patients were positive with both methods. One patients was positive with {sup 14}C-method and negative with the {sup 13}C-urea breath test. 61 patients were analyzed with the {sup 13}C-urea breath test and the urease test. 30 patients were negative and 30 patients were positive with both methods, whereas one patient with a negative urease test had a positive breath test. {sup 13}C-urea breath test analyzed with isotope-selective non-dispersive infrared spectrometry is a fast, simple, non-radioactive, non-invasive, convenient and reliable method for the diagnosis of Helicobacter pylori infection. 12 refs., 2 figs., 1 tab.

  10. Microdose 14C urea breath test for the diagnosis of Helicobacter pylori: a survey in Iranian population

    Directory of Open Access Journals (Sweden)

    Reza Dowlatabadi Bazaz

    2005-01-01

    Full Text Available The carbon -14 urea breath test (UBTis a non-invasive and simple method for the diagnosis of Helicobacter pylori infection. Attempts have been made to use lower doses of 14C-urea in the UBT in order to reduce the radiation risk of the test. The aim of this study was to assess the accuracy of a microdose (1 µCi [37 KBq] 14C-UBT in Iranian population for validation of its diagnostic accuracy against gold standard methods. Eighty and two patients were subjected to upper gastrointestinal endoscopy as well as 14C-UBT in one week. Rapid urease test and histological examinations were used as gold standard. Breath samples were collected 10, 20 and 30 minute after ingestion of 1 µCi of 14C- urea solution and their activities were measured using a scintillation counter and expressed as counts per minute (cpm and disintegration per minute (dpm. Good agreement was observed between the 14C-UBT and gold standard for samples which were collected 20 minutes after 14C-urea administration. The 14CUBT showed 100% sensitivity, 95% specificity, 95.45% positive predictive value, 100% negative predictive value and 97.50% accuracy. The results of this study showed good concordance between the 14C-UBT and invasive methods.

  11. Nondispersive isotope-selective infrared spectroscopy: A new analytical method for {sup 13}C-urea breath tests

    Energy Technology Data Exchange (ETDEWEB)

    Braden, B.; Schaefer, F.; Caspary, W.F.; Lembcke, B. [Johann Wolfgang Goethe Univ., Frankfurt am Main (Germany)

    1996-05-01

    Currently, stable isotope techniques in breath tests using {sup 13}C-labeled substrates are limited to a few centers equipped with expensive and complex isotope spectrometry (IRMS). Although breath samples can be mailed to these centers, widespread application of {sup 13}C-breath tests would be more feasible with a cheaper and more practicable analysis system at hand. The authors therefore tested the newly developed nondispersive isotope-selective infrared spectrometer (NDIRS) with reference to IRMS in a clinical setting, comparing the results of both techniques in 538 consecutive {sup 13}C-urea breath tests performed for the detection of helicobacter pylori infection. With NDIRS five false-positive and three false-negative results were observed; that is, the sensitivity of NDIRS was 98.3%, and the specificity was 98.6%. When running this large number of breath tests in 3 days, the NDIRS proved to be a reliable, stable, and easy-to-operate analytical tool, which is well qualified for gastroenterologic application in the diagnostic routine. Both the price and the easy handling of NDIRS will facilitate the widespread use of the noninvasive stable isotope technique for {sup 13}C breath test. 22 refs., 3 figs., 1 tab.

  12. 13[C]-urea breath test as a novel point-of-care biomarker for tuberculosis treatment and diagnosis.

    Directory of Open Access Journals (Sweden)

    Mandeep S Jassal

    Full Text Available BACKGROUND: Pathogen-specific metabolic pathways may be detected by breath tests based on introduction of stable isotopically-labeled substrates and detection of labeled products in exhaled breath using portable infrared spectrometers. METHODOLOGY/PRINCIPAL FINDINGS: We tested whether mycobacterial urease activity could be utilized in such a breath test format as the basis of a novel biomarker and diagnostic for pulmonary TB. Sensitized New-Zealand White Rabbits underwent bronchoscopic infection with either Mycobacterium bovis or Mycobacterium tuberculosis. Rabbits were treated with 25 mg/kg of isoniazid (INH approximately 2 months after infection when significant cavitary lung pathology was present. [(13C] urea was instilled directly into the lungs of intubated rabbits at selected time points, exhaled air samples analyzed, and the kinetics of delta(13CO(2 formation were determined. Samples obtained prior to inoculation served as control samples for background (13CO(2 conversion in the rabbit model. (13CO(2, from metabolic conversion of [(13C]-urea by mycobacterial urease activity, was readily detectable in the exhaled breath of infected rabbits within 15 minutes of administration. Analyses showed a rapid increase in the rate of (13CO(2 formation both early in disease and prior to treatment with INH. Following INH treatment, all evaluable rabbits showed a decrease in the rate of (13CO(2 formation. CONCLUSIONS/SIGNIFICANCE: Urea breath testing may provide a useful diagnostic and biomarker assay for tuberculosis and for treatment response. Future work will test specificity for M. tuberculosis using lung-targeted dry powder inhalation formulations, combined with co-administering oral urease inhibitors together with a saturating oral dose of unlabeled urea, which would prevent the delta(13CO(2 signal from urease-positive gastrointestinal organisms.

  13. Validation of low activity {sup 14}C-urea breath test in diagnosis of ``Helicobacter pylori``in humans

    Energy Technology Data Exchange (ETDEWEB)

    Bielanski, W.; Konturek, S.J.; Dobrzanka, M.J.; Plonka, M.; Sito, E.; Stachura, J. [Uniwersytet Jagiellonski, Cracow (Poland); Hoffman, S.R.; Marshall, B.J. [Tri-Med Specialtis, Charlottenville, VA (United States)

    1996-12-31

    Etiologic role for ``Helicobacter pylori`` (HP) seems to be well established in gastric pathology. The high urease activity of HP can be used to detect this bacterium by non-invasive urea breath tests (UBT). We validated the low activity version of the test in which 37 kBq {sup 14}C-urea is given orally in capsule. With the cut off value {>=} 1.66 Bq (100 DPM) as positive, UBT results correlated highly significant with combined results for invasive methods, i.e. CLO-test + Histology score. The reproducibility of the test was 100%. The results obtained for the breath test performed locally were almost identical with that read at remote laboratory. The data found for fasting and fed states of subjects agreed in 87%. When {sup 14}C-urea was confined in the mouth of both HP positive and HP negative patients UBT showed the presence of urease activity in the mouth cavity. (author). 21 refs, 2 figs, 1 tab.

  14. Validation of the 13C-urea breath test for use in cheetahs (Acinonyx jubatus) with Helicobacter.

    Science.gov (United States)

    Chatfield, Jenifer; Citino, Scott; Munson, Linda; Konopka, Stanley

    2004-06-01

    Historically, therapeutic monitoring for prescribed eradication treatment of Helicobacter in cheetahs (Acinonyx jubatus) with associated gastritis has been accomplished only through endoscopic biopsies. The 13C-urea breath test (UBT) can offer an alternative to repeated biopsies for therapeutic monitoring. Five male and five female cheetahs and one male Sumatran tiger (Panthera tigris) were studied. All were clinically healthy before and after this investigation. Breath samples of end-tidal expiration were taken before and after administration of a 13C-enriched urea solution through a gastroesophageal tube. Twenty-milliliter breath samples were taken at 10, 20, 30, and 40 min after administration of the urea solution. The results of the breath analysis were compared with the results of rapid urease testing, histopathologic examination, and impression smears of gastric biopsies taken at the time of the breath test. The sensitivity and specificity for the 13C-UBT in this investigation were 100%. and the positive predictive value and negative predictive value were both 100%. Although the 13C-UBT is a good noninvasive diagnostic tool for monitoring the presence of Helicobacter sp. in the gastric mucosa, endoscopy should still be used for initial diagnosis and grading of gastritis and for monitoring the progression of disease in cheetahs. The 13C-UBT is a valuable, simple, accurate, and sensitive tool for monitoring eradication of Helicobacter during therapy for clinical gastritis.

  15. Investigation of the association between glaucoma and Helicobacter pylori infection using the {sup 14}C-urea breath test

    Energy Technology Data Exchange (ETDEWEB)

    Tuzcu, Esra Ayhan; Aydogan, Fusun; Motor, Vicdan Koksaldi; Ilhan, Ozgur; Daglioglu, Mutlu Cihan; Coskun, Mesut; Parlakfikirer, Nihan; Keskin, Ugurcan, E-mail: drayhant@hotmail.com [Medical Faculty, Mustafa Kemal University, Hatay (Turkey)

    2015-07-01

    Purpose: to investigate the association between glaucoma and Helicobacter pylori infection by evaluating for the presence of H. pylori infection in patients with glaucoma using the 14C-urea breath test (14C-UBT). Methods: Using 14C-UBT, H. pylori infection positivity was compared between a group of patients with primary open-angle glaucoma and a control group with normal intraocular pressure and a normal optic disc or normal perimetry. Results: the 14C-UBT was positive in 18 (51.42%) out of 35 patients in the glaucoma group and in 15 (42.85%) out of 35 patients in the control group. H. pylori infection positivity rates were similar between the glaucoma and control groups (p>0.05). Conclusion: according to the 14C-UBT, there is no association between primary open-angle glaucoma and H. pylori infection. (author)

  16. 14C-urea breath test in patients undergoing anti-tuberculosis therapy

    Institute of Scientific and Technical Information of China (English)

    Sayed Amir Mirbagheri; Amir Ali Sohrabpour; Mehrdad Hasibi; Babak Moghimi; Mehdi Mohamadnejad

    2005-01-01

    AIM: Urea breath test (UBT) is a non-invasive diagnostic test for detecting the presence of Helicobacter pylori(H pylori).In this study we evaluated the effect of anti-tuberculosis therapy on the results of 14C-UBT.METHODS: Patients, with the diagnosis of tuberculosis (TB) who had a positive UBT at the point of starting antiTB therapy, were included. None had a history of peptic ulcer disease or had taken antibiotics, bismuth compounds and/or PPI in the previous month, 14C-UBT was repeated at the end of the second month and the end of treatment period and one month after completion of treatment course.RESULTS: Thirty-five patients (23 males) were enrolled.14C-UBT was negative in all 35 patients (100%) at the end of the second month and remained negative in 30cases (85.7%) at the end of the treatment course. One month after completion of treatment course, UBT remained negative in 13 patients (37.1%).CONCLUSION: Our report underscores the need for caution while interpreting urea breath test results in patients undergoing anti-TB therapy. Furthermore, the combination of drugs used in this study resulted in H pylori eradication in a minority of patients.

  17. Turnover of carbon in the {sup 13}C-urea breath test for the detection of Helicobacter pylori infection

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Vladimir E.; Andreazzi, Mariana; Cury, Caio S.; Bassetto Junior, Carlos A.Z.; Rodrigues, Maria A.M.; Ducatti, Carlos, E-mail: vladimir@ibb.unesp.br, E-mail: ducatti@ibb.unesp.br, E-mail: mariana.andreazazi@gmail.com, E-mail: caiocury@hotmail.com, E-mail: juniorbassett@hotmail.com, E-mail: mariar@fmb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2013-07-01

    To obtain a standard protocol for the application of {sup 13}C-urea breath test ({sup 13}C-UBT) analyzed by Isotope Ratio Mass Spectrometer (IRMS) to detect helicobacter pylori infection in the population is necessary to know the behavior of the turnover of {sup 13}C during the test in different individuals. The aims of this study was to find out a pattern for the turnover of the {sup 13}C in the {sup 13}C-UBT, analyzed by IRMS, in patients infected with H. pylori, in a Brazilian population, to define a protocol test application. We found that the isotopic ratio {sup 13}C/{sup 12}C in expired CO{sub 2} from patients infected with H. pylori and subjected to {sup 13}C-UBT does not follow a single pattern of behavior. However this behavior can be similar in subjects having the same maximum values following an inverse proportional relationship between the maximum value and the time of appearance in the curve. (author)

  18. Performance of Helicobacter pylori acid extract and urease enzyme-linked immunosorbent assays in relation to 14C-urea breath test.

    Science.gov (United States)

    von Wulffen, H; Gatermann, S; Windler, E; Gabbe, E; Heinrich, H C

    1993-09-01

    The 14C-urea breath test has been shown to be a reliable non-invasive method to detect the presence or absence of H. pylori infection. Alternatively, a number of techniques have been devised to detect circulating antibodies against H. pylori in serum, the most commonly used being enzyme-linked immunosorbent assays (ELISA). In the present study we compared the value of two ELISA antigen preparations, an acid glycine extract and a urease preparation, in relation to the results achieved in a 14C-urea breath test. Seventy-five gastroenterology outpatients were screened for the presence of H. pylori infection using the urea breath test. At the same time serum specimens were obtained. Thirty-seven patients had a positive breath test, i.e. they expired more than 2% of the oral 14C test dose within 60 min. Using the breath test as reference, sensitivity and specificity for the acid extract were 89.2% and 84.2% respectively, and for the urease ELISA 81.1% and 89.5%. Agreement between the two ELISAs was found in 82.7%, overall agreement between all three tests was observed in 77.3%. All three tests were found to be useful for monitoring therapy directed against H. pylori.

  19. Comparison of the diagnostic performance of {sup 14}C-urea breath test according to counting method for the diagnosis of Helicobacter pylori infection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Woo; Lim, Seok Tae; Lee, Seung Ok; Sohn, Myung Hee [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2005-02-15

    {sup 14}C-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylon, (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid {sup 14}C-UBT (Heliprobe method), which was equipped with Geiger-Muller counter and compared the results with those obtained by using the conventional method. Forty-nine patients with dyspepsia underwent gastroduodenoscopy and {sup 14}C-UBT. A 37 KBq {sup 14}C-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Heliprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.

  20. Application of isotope-selective non-dispersive infrared spectrometry for the evaluation of the 13C-urea breath test: comparison with three concordant methods

    Directory of Open Access Journals (Sweden)

    Coelho L.G.V.

    1999-01-01

    Full Text Available The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT, urease test and histologic examination for the diagnosis of H. pylori (HP infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21 days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9 for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71 for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg, the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18 in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17. IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.

  1. {sup 14}C urea breath test kit- an evaluation of a compact, cost-effective kit for the detection of H. pylori

    Energy Technology Data Exchange (ETDEWEB)

    Bellon, M.S. [Royal Adelaide Hospital, SA (Australia). Dept of Nuclear Medicine

    1998-03-01

    Full text: Helicobacter pylori infection of the gastric mucosa causes active chronic gastritis and peptic ulceration. Carbon-14 urea breath testing has been well documented in its ability to detect the presence of H. pylori. The aims of this study were to evaluate and refine the test to substantially reduce costs and improve its simplicity, availability and accuracy. We reviewed the results of 138 patients who underwent {sup 14}C urea breath testing for the detection of H. pylori utilising a kit developed at the Royal Adelaide Hospital. Modifications to the standard technique that were assessed included the relevance of buccal cleansing, single sample v multiple sampling, use of alternative CO{sub 2} absorbers and sampling techniques. In those patients with positive biopsy results, a test sensitivity of 100% was achieved. No buccal cleansing is necessary (45% oral contamination without brushing teeth v 41% with). A single breath sample only at 15 min resulted in 100% sensitivity. Alternative (cheaper and safer) CO{sub 2} absorbers such as KOH can be used. Based on these results, modifications to this well documented test have enabled us to substantially reduce costs, improve simplicity and safety and increase accuracy and availability of the test for the detection of Helicobacter pylori.

  2. Efficacy and cost-effectiveness of the 13C-urea breath test as the primary diagnostic investigation for the detection of Helicobacter pylori infection compared to invasive and non-invasive diagnostic tests

    Directory of Open Access Journals (Sweden)

    Greiner, Wolfgang

    2009-10-01

    Full Text Available Background: Helicobacter pylori (H. pylori is one of the most common bacterial infections in humans. There is a risk factor for gastric or duodenal ulcers, gastric cancer and MALT (Mucosa Associated Lymphoid Tissue-Lymphomas. There are several invasive and non-invasive methods available for the diagnosis of H. pylori. The 13C-urea breath test is a non-invasive method recommended for monitoring H. pylori eradication therapy. However, this test is not yet used for primary assessment of H. pylori in Germany. Objectives: What are the clinical and health economic benefits of the 13C-urea breath test in the primary assessment of H. pylori compared to other invasive and non-invasive methods? Methods: A systematic literature search including a hand search was performed for studies investigating test criteria and cost-effectiveness of the 13C-urea breath test in comparison to other methods used in the primary assessment of H. pylori. Only studies that directly compared the 13C-urea breath test to other H. pylori-tests were included. For the medical part, biopsy-based tests were used as the gold standard. Results: 30 medical studies are included. Compared to the immunoglobulin G (IgG test, the sensitivity of the 13C-urea breath test is higher in twelve studies, lower in six studies and one study reports no differences. The specificity is higher in 13 studies, lower in three studies and two studies report no differences. Compared to the stool antigen test, the sensitivity of the 13C-urea breath test is higher in nine studies, lower in three studies and one study reports no difference. The specificity is higher in nine studies, lower in two studies and two studies report no differences. Compared to the urease test, the sensitivity of the 13C-urea breath test is higher in four studies, lower in three studies and four studies report no differences. The specificity is higher in five studies, lower in five studies and one study reports no difference. Compared

  3. A simplified 13C-Urea breath test (13C-UBT) in the diagnosis of Helicobacter pylori (HP) infection

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, T.; Bartholomeusz, F.D. L.; Bellon, M.S.; Chatterton, B.E. [Royal Adelaide Hospital, Adelaide. SA (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The Urea Breath Test (UBT) is an accurate, noninvasive means of assessing the presence of Helicobacter pylori in the stomach. Two tests are currently available, using 13C- and 14C-labelled urea, respectively. 13C is a nonradioactive isotope, unlike 14C, but the 13C-UBT is technically more challenging. The aim of this study was to determine the accuracy of a simplified 13C-UBT with no test meal, using the 14C-UBT as the previously validated standard. 76 studies were performed on 72 patients; 4 patients performed the test twice. 28 patients were female, 44 male. The mean age was 51.1 years (range 23-86 years). 42 patients presented for post-eradication follow up, and 30 for initial diagnosis. All subjects underwent a 14C-UBT with a 15 minute sample. The 13C-UBT was then performed without a test meal and the breath samples obtained at baseline and 20 minutes. Of the 14C-UBT studies, 27 were positive, ranging from 1372 to 10,987 DPM (Normal <1000 DPM), and 49 were negative, range 177-946 DPM. 26 of the 13C-UBT studies were positive, with a Delta value ranging from 4.29-47.89 (Normal: Delta <3.5), and 50 were negative, range -0.20-2.80. There were 1 false-positive and 2 false-negative 13-UBT studies. This yielded a sensitivity of 92.6% and specificity of 98.0% for the simplified 13C-UBT. From these results we conclude that the simplified 13C-UBT is an accurate means of detecting the presence of Helicobacter pylori within the stomach

  4. Cost effectiveness analysis of population-based serology screening and 13C-Urea breath test for Helicobacter pylori to prevent gastric cancer: A markov model

    Institute of Scientific and Technical Information of China (English)

    Feng Xie; Nan Luo; Hin-Peng Lee

    2008-01-01

    AIM: To compare the costs and effectiveness of no screening and no eradication therapy, the populationbased Hdlicobacter pylori (H pylori) serology screening with eradication therapy and 13C-Urea breath test (UBT)with eradication therapy.METHODS: A tarkov model simulation was carried out in all 237900 Chinese males with age between 35 and 44 from the perspective of the public healthcare provider in Singapore. The main outcome measures were the costs, number of gastric cancer cases prevented, life years saved, and quality-adjusted life years (QALYs)gained from screening age to death. The uncertainty surrounding the cost-effectiveness ratio was addressed by one-way sensitivity analyses.RESULTS: Compared to no screening, the incremental cost-effectiveness ratio (ICER) was $16166 per life year saved or $13571 per QALY gained for the serology screening, and $38792 per life year saved and $32525 per QALY gained for the UBT. The ICER was $477079 per life year saved or $390337 per QALY gained for the UBT compared to the serology screening. The costeffectiveness of serology screening over the UBT was robust to most parameters in the model.CONCLUSION: The population-based serology screening for H pylori was more cost-effective than the UBT in prevention of gastric cancer in Singapore Chinese males.

  5. A new, practical, low-dose {sup 14}C-urea breath test for the diagnosis of Helicobacter pylori infection: clinical validation and comparison with the standard method

    Energy Technology Data Exchange (ETDEWEB)

    Oeztuerk, Emel; Ilgan, Seyfettin; Arslan, Nuri; Oezgueven, Mehmet [Department of Nuclear Medicine, Guelhane Military Medical Academy and Medical School, 06018, Etlik, Ankara (Turkey); Yesilova, Zeki; Erdil, Ahmet; Dagalp, Kemal [Department of Gastroenterology, Guelhane Military Medical Academy and Medical School, Etlik, Ankara (Turkey); Celasun, Buelent [Department of Pathology, Guelhane Military Medical Academy and Medical School, Etlik, Ankara (Turkey); Ovali, Oender [Department of Internal Medicine, Guelhane Military Medical Academy and Medical School, Etlik, Ankara (Turkey); Bayhan, Hikmet [Department of Nuclear Medicine, Acbadem Hospital, Istanbul (Turkey)

    2003-11-01

    The carbon-14 urea breath test (UBT) is a reliable and non-invasive technique for the diagnosis of Helicobacter pylori (HP) infection. In this study we evaluated the diagnostic performance of a new, practical and low-dose {sup 14}C-UBT system for the diagnosis of HP and compared the results with those obtained using the standard method. Seventy-five patients (56 female, 19 male) with dyspepsia underwent {sup 14}C-UBT and endoscopy with antral biopsies for histological analysis. The rapid urease test (CLO test) was applied to 50 of these patients. After a 6-h fasting period, a 37-kBq {sup 14}C-urea capsule was swallowed for UBT. Breath samples were collected and counted using two different methods, the Heliprobe method and the standard method. In the Heliprobe method, patients exhaled into a special dry cartridge system (Heliprobe BreathCard) at 10 min. The activities of the cartridges were counted using a designated small GM counter system (Heliprobe analyser). Results were expressed both as counts per minute (HCPM) and as grade (0, not infected; 1, equivocal; 2, infected) according to the counts. In the standard method, breath samples were collected by trapping in a liquid CO{sub 2} absorber. Radioactivity was counted as disintegrations per minute (SDPM) using a liquid scintillation counter after addition of a liquid scintillation cocktail. Histological examination was used as a gold standard. Two patients were excluded from the study because of inadequate biopsy sampling. Forty-eight patients (65%) were found to be HP positive on histology. The Heliprobe method correctly classified 48 of 48 HP-positive patients and 19 of 25 HP-negative patients (sensitivity 100%, specificity 76%, PPV 88%, NPV 100%, accuracy 91%). The standard method correctly classified 48 of 48 HP-positive patients and 20 of 25 HP-negative patients (sensitivity 100%, specificity 80%, PPV 90%, NPV 100%, accuracy 93%). On the other hand, the CLO test identified 26 of 32 HP-positive and 12 of 16 HP

  6. MIN {sup 14}C UBT: A combination of gastric basal transit and {sup 14}C-urea breath test for the detection of helicobacter pylori infection in human beings

    Energy Technology Data Exchange (ETDEWEB)

    Zubillaga, M.; Oliveri, P.; Calcagno, M.L.; Goldman, C.; Caro, R.; Mitta, A.; Degrossi, O.; Boccio, J

    1997-08-01

    The purpose of this work is to demonstrate that the {sup 14}C-urea breath test (UBT) performed at different times combined with the study of the gastric basal transit, which evaluates the intragastric displacement of a labeled solution under fasting conditions, has the advantage of being representative of the whole stomach surface and constitutes a non-aggressive test for the detection of H. pylori. This test, which has been called MIN {sup 14}C UBT, is a modification of the conventional {sup 14}C UBT in which low volumes of a solution of {sup 14}C-urea together with {sup 99m}Tc-sulfur colloid are administered. The {sup 99m}Tc-sulfur colloid is not absorbed in the gastrointestinal tract and has the great advantage of allowing the 'visualization' of the transit of the {sup 14}C-urea within the gastrointestinal tract. This modification allows the simultaneous determination of the production of the {sup 14}CO{sub 2} and the place where this process occurs. The results show that there is a good correlation between the images obtained and the breath samples collected. We found that this test has a sensitivity of 98% and a specificity of 96% for H. pylori detection.

  7. Diagnosis of Helicobacter pylori infection; Culture, microscopy of biopsy smears, and the rapid urease test compared with the sup 14 C-urea breath test. Diagnostikk av Helicobacter pylori-infeksjon; Urease hurtigtest, mikroskopi av utstryk, og dyrking av ventrikkelbiopsi sammenlignet med sup 14 C-urea-pusteproeven

    Energy Technology Data Exchange (ETDEWEB)

    Nysaeter, G.; Berstad, K.; Weberg, R.; Berstad, A.; Hardardottir, H. (Haukeland Hospital, Bergen (Norway))

    1992-08-01

    By employing the {sup 14}C-urea breath test as the reference methods the authors determined the specificity and sensitivity of three bioptic methods for diagnosis of Helicobacter pylori infection in 103 subjects. All biopsy specimens were obtained from the gastric antrum. For culture the specificity was 100%. Its applicability was reduced, however, by a low sensitivity (73.8%) and a delay of several days before the final result was available. Microscopy of Loeffler-stained biopsy smears yielded a specificity of 100% and a sensitivity of 92.9%, but the method was regarded time-consuming. The rapid urease test yielded a specificity of 98.4% and a sensitivity of 85.7%. Being quick, simple and inexpensive, the rapid urease test is well suited for routine use in gastroscopy. 17 refs., 4 tabs.

  8. Comparison of a monoclonal antigen stool test (Hp StAR) with the 13C-urea breath test in monitoring Helicobacter pylori eradication therapy

    Institute of Scientific and Technical Information of China (English)

    Francesco Perri; Michele Quitadamo; Rosalba Ricciardi; Ada Piepoli; Rosa Cotugno; Annamaria Gentile; Alberto Pilotto; Angelo Andriulli

    2005-01-01

    AIM: To evaluate the agreement between a mAb-based stool test (HP StAR) and the urea breath test (UBT) in monitoring (H pylori) infection after eradication therapy.METHODS: Patients with discordant results on UBT and Hp StAR underwent endoscopy with biopsies for rapid urease test, culture, and histology to confirm H pylori status.RESULTS: Among 250 patients (50±14 years), 240 (96.0%) had concordant UBT and Hp StAR tests with a significant correlation between DOB and A values (R = 0.87; P<0.0001).The remaining 10 (4.0%) patients had discordant tests (positive Hp StAR and negative UBT) with the Hp StAR inaccurate in five cases (false positive) and UBT inaccurate in the other five cases (false negative). The "maximal expected" sensitivity, specificity, +PV, -PV, +LR, and -LR were 91%, 100%, 100%, 97.4%, ∞, and 8.2 respectively,for the UBT, and 100%, 97.4%, 91%, 100%, 38.8, and 0,respectively, for the Hp StAR. Overall accuracy for both tests was 98%.CONCLUSION: Both the UBT and the Hp StAR are equally accurate in monitoring H pylori infection. Nowadays,the choice of the "best" non-invasive H pylori test in the post-treatment setting should be done not only in terms of diagnostic accuracy but also in view of cost and local facilities.

  9. VALIDATION OF 14C-UREA BREATH TEST FOR DIAGNOSIS OF Helicobacter pylori Validação do teste expiratório com 14C-uréia para o diagnóstico do Helicobacter pylori

    Directory of Open Access Journals (Sweden)

    Rejane MATTAR

    1999-01-01

    Full Text Available The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (pO teste expiratório com 14C-uréia diagnostica infecção pelo Helicobacter pylori no estômago. A urease, produzida por esta bactéria, quebra a 14C-uréia, resultando em HCO3- e NH4+, sendo expirado 14CO2 pelos pulmões e quantificado, então, por contador Beta. O objetivo do nosso estudo foi validar o teste expiratório com 14C-uréia, determinando o tempo ideal de coleta da amostra e o valor de corte. Foi definido o tempo de 20 min para coleta do exame após a ingestão de 5 uCi de 14C-uréia com valor de corte de 562 cpm. A sensibilidade e a especificidade do teste foram de 100% aos 20 min. As diferenças de contagens entre os grupos Helicobacter pylori negativos e Helicobacter pylori positivos foram estatisticamente significativas (p<0,0001. As pacientes do sexo feminino, aos 20 min apresentaram contagens superiores às dos pacientes do sexo masculino (p=0,005. É preciso verificar se as mulheres têm maior densidade bacteriana, ou se é pelo fato dos homens expirarem mais CO2, diluindo a amostra. O teste expiratório com 14C-uréia é método diagnóstico não invasivo, muito sensível, específico e barato.

  10. Comparison of three stool antigen assays with the 13C- urea breath test for the primary diagnosis of Helicobacter pylori infection and monitoring treatment outcome.

    LENUS (Irish Health Repository)

    Hooton, Carmel

    2012-02-03

    BACKGROUND: The urea breath test (UBT) is the gold-standard non-invasive test for the detection of Helicobacter pylori infection, however, the lack of availability of the UBT due to the high cost of the test, and in particular the need for expensive analytical instrumentation, limits the usefulness of this method. Stool antigen assays may offer an alternative non-invasive method for the diagnosis of infection. OBJECTIVE: To compare the accuracy of three stool antigen assays (HpSA, IDEIA HpStAR, and ImmunoCard STAT) against the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome. METHODS: A total of 102 patients attending two gastroenterology day-case clinics for the investigation of dyspepsia were included. Each patient provided breath and stool samples for analysis. Patients who tested positive for H. pylori by the validated UBT were prescribed triple therapy and invited to return for repeat breath and stool sample analysis 6 weeks post-treatment. RESULTS: Of the 102 patients tested, 48 were diagnosed with H. pylori infection by the UBT. The HpSA assay interpreted 38 of these as positive (79% sensitive). Of the 54 UBT-negative patients the HpSA assay interpreted all 54 as negative (100% specific). The IDEIA HpStAR assay correctly identified 44 patients as positive (92% sensitive) and 50 as negative (92.5% specific). The ImmunoCard STAT assay interpreted 38 patients as positive (79% sensitive) and 52 as negative (96.3% specific). CONCLUSION: The findings indicate that the IDEIA HpStAR stool antigen kit is the most accurate assay of the three assays evaluated, and possibly represents a viable alternative to the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome.

  11. 口臭患者14C呼气试验检测的结果分析%Analysis of 14C-Urea Breath Test in Patients with Halitosis

    Institute of Scientific and Technical Information of China (English)

    陈建中; 张旭峰; 张斌; 李黎; 童妙春; 陈驰

    2012-01-01

    Objective To explore the relationship between halitosis and the infection of helicobacter pylori (HP). Methods The results of l4C-urea breath test of 59 normal people, 50 patients with halitosis only and 56 patients infected by both halitosis and digestive diseases were analyzed. Results It showed that the 14C content and HP positive rate in group infected by both halitosis and digestive diseases were much higher than that of halitosis only group and normal people group (P <0.05). Conclusion The infection of Helicobacter pylori is an important factor but not only factor of halitosis.%目的 探讨口臭与幽门螺旋杆菌及其它因素的关系.方法 对59名正常组、50例单纯口臭组患者、56例口臭伴消化道疾病组患者14C 呼气试验的结果进行分析.结果 分析结果表明,口臭伴消化道疾病组14C呼气试验含量明显高于单纯口臭组和正常组(P<0.05),阳性率也明显高于单纯口臭组和正常组(P<0.05).结论 幽门螺旋杆菌感染是口臭的重要原因,但不是唯一原因.

  12. A methodological aspect of the {sup 14}C-urea breath test used in Helicobacter pylori diagnosis; Wybrany aspekt metodologiczny testu oddechowego z mocznikiem znakowanym stosowanego w diagnostyce zakazenia Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Kopanski, Z.; Niziol, J.; Micherdzinski, J.; Wasilewska-Radwanska, M.; Cienciala, A.; Lasa, J.; Witkowska, B. [Szpital Wojskowy, Cracow (Poland)]|[Institute of Physics and Nuclear Techniques, Academy of Mining and Metallurgy, Cracow (Poland)]|[Institute of Nuclear Physics, Cracow (Poland)

    1996-12-31

    The main purpose of those investigations was optimisation of the performing time of the breath test with {sup 14}C-labelled urea which reveals Helicobacter pylori infection. It was analysed 117 species, preselected according to endoscopy and histopathology results, 56 of them have suffered from chronic gastritis and 61 from gastric ulcer disease. Using microbiology diagnosis (culture + IFP test) it was found that 86 species were H. pylori infected. This group of patients were next subject to investigations with the breath test with {sup 14}C-labelled urea. Measurements of radioactivity of breathe air have been carried out for 30 minutes. The obtained results allow us to maintain that the optimal time of duration of the test described above is 30 minutes. (author) 38 refs, 2 tabs, 1 fig

  13. Validación de método simplificado de la prueba en aliento con urea-13C para diagnóstico de infección por Helicobacter pylori Validation of a simplified method of the 13C urea breath test for diagnosis of Helicobacter pylori

    Directory of Open Access Journals (Sweden)

    N. X. Ortiz-Olvera Nayeli

    2007-07-01

    Full Text Available Objetivo: validar un método simplificado de la prueba en aliento con urea-13C (PAU-13Cs para el diagnóstico de infección por Helicobacter pylori (H. pylori, con administración simultánea de 50 mg de urea-13C y 2 g de ácido cítrico. Material y métodos: se estudiaron 88 pacientes (49 mujeres y 39 hombres; con promedio de edad 45 ± 15 años, referidos para endoscopia gastrointestinal y toma de biopsias. La PAU-13Cs se realizó en ayuno. Se recolectaron las muestras de aire espirado en tubos de cristal de 10 ml, antes y 30 minutos después de administrar simultáneamente 50 mg de urea-13C y 2 g de ácido cítrico disueltos en 200 ml de agua. Las muestras se analizaron por espectrometría de masas. El diagnóstico de infección se consideró cuando el cultivo y/o la biopsia y serología fueron positivas para H. pylori. Resultados: cincuenta y un pacientes (57,95% fueron positivos, 30 (34,10% negativos para H. pylori y 7 (7,95% casos se consideraron indeterminados. La sensibilidad, especificidad, valor predictivo positivo y negativo de PAU-13Cs fue de 90,2, 93,3, 95,8 y 84,8%, respectivamente. Con exactitud de 91,4%. Conclusión: la administración simultánea de 50 mg de urea-13C y 2 g de ácido cítrico, representa una alternativa para el diagnóstico no invasivo de infección por H. pylori, debido a que conserva la certeza diagnóstica de la PAU-13C.Objective: to validate a simplified 13C-urea breath test (13C-UBT method for the diagnosis of H. pylori infection. Material and methods: patients referred for gastrointestinal endoscopy and biopsy were included, and a 13C-UBT was performed after a 6-hour fast. Breath samples were collected in 10 ml glass tubes before and 30 min after the simultaneous administration of 50 mg of 13C-urea and 2 g of citric acid in 200 ml of water. All breath samples were analyzed using isotope ratio mass spectrometry. The diagnosis of H. pylori infection was established with a positive culture and/or positive

  14. The interest of the {sup 13}C urea breath test for the diagnostic and monitoring of chronic duodenal ulcer; Interet du test respiratoire a l`uree {sup 13}C dans le diagnostic et le suivi de l`ulcere duodenal chronique

    Energy Technology Data Exchange (ETDEWEB)

    Rousseau-Tsangaris, M. [INBIOMED, 69 - Lyon (France); Centarti, M.; Mion, F.; Minaire, Y. [Hopital Edouard-Herriot, 69 - Lyon (France); Brazier, J.L. [Faculte de Pharmacie, 69 - Lyon (France)

    1994-12-31

    Duodenal ulcer is very frequently associated with Helicobacter pylori (Hp) present in the gastric mucous membrane. Breath tests with {sup 13}C-labelled urea have been carried out for the detection of Hp; these tests could be more sensitive than gastric biopsies, because of the heterogenous distribution of the bacteria in the mucous membrane. This breath test may be used repetitively and allows for a non-intrusive monitoring of the Hp eradication after treatment. 12 refs.

  15. Breath alcohol test

    Science.gov (United States)

    Alcohol test - breath ... There are various brands of breath alcohol tests. Each one uses a different method to test the level of alcohol in the breath. The machine may be electronic or manual. One ...

  16. Optoacoustic 13C-breath test analyzer

    Science.gov (United States)

    Harde, Hermann; Helmrich, Günther; Wolff, Marcus

    2010-02-01

    The composition and concentration of exhaled volatile gases reflects the physical ability of a patient. Therefore, a breath analysis allows to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that employs a compact and simple set-up based on photoacoustic spectroscopy. It consists of two identical photoacoustic cells containing two breath samples, one taken before and one after capturing an isotope-marked substrate, where the most common isotope 12C is replaced to a large extent by 13C. The analyzer measures simultaneously the relative CO2 isotopologue concentrations in both samples by exciting the molecules on specially selected absorption lines with a semiconductor laser operating at a wavelength of 2.744 μm. For a reliable diagnosis changes of the 13CO2 concentration of 1% in the exhaled breath have to be detected at a concentration level of this isotope in the breath of about 500 ppm.

  17. A 20-minute breath test for helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, B.J.; Plankey, M.W.; Hoffman, S.R.; Boyd, C.L.; Dye, K.R.; Frierson, H.F. Jr.; Guerrant, R.L.; McCallum, R.W. (Univ. of Virginia Health Sciences Center, Charlottesville (USA))

    1991-04-01

    In this study, we evaluated a simplified rapid {sup 14}C-urea breath test for the diagnosis of Helicobacter pylori. Fasting patients undergoing initial assessment for H. pylori drank 5 microCi of {sup 14}C-urea in 20 ml of water. Breath was collected at intervals for 30 min. Samples were counted in a beta-counter, and the results were expressed as counts per minute (cpm). In the same week, patients underwent endoscopy, and a blinded investigator examined biopsy samples of gastric mucosa by culture and histology for H. pylori. There were 49 H. pylori-negative (HP-) and 104 H. pylori-positive (HP+) patients in the study. HP+ patients expired a mean of 4398 cpm (SD 2468) per mmol CO{sub 2} in a sample taken 20 min after ingestion of the isotope. In contrast, HP--patients expired only 340 cpm (SD 196). If the mean +3 SD of HP- patients was used as a cutoff value, the 20-minute sample gave a sensitivity of 97% and a specificity of 100% for detecting H. pylori. The radiation exposure from this test is less than 1% of that received from an upper gastrointestinal series, and the short collection time makes it both convenient and cost effective.

  18. Almagate interference in breath test results for the diagnosis of Helicobacter pylori infection

    Directory of Open Access Journals (Sweden)

    Carles Pons

    2014-08-01

    Full Text Available Background: Infection by Helicobacter pylori is common and affects both genders at any age. The 13C-urea breath test is a widely used test for the diagnosis of this infection. However, multiple drugs used for the treatment of Helicobacter pylori infection symptoms have interactions with this breath test that generate false negative results. This observational study was to assess the potential interaction between almagate and the breath test. Methods: Thirty subjects on almagate therapy who underwent a breath test were included. If the result was negative, almagate was withdrawn for a month and the breath test was then repeated. Results: In general, 51.9 % of assessed subjects had a negative result after the first test, and 100 % of these also had a negative result after the second test. Conclusions: It was concluded that the use of almagate does not interfere in breath test results. These results provide a drug therapy option for the treatment of symptoms associated with Helicobacter pylori infection during the diagnostic process.

  19. Utilization of urea micro dose with {sup 14} C in breath test to detect the Helicobacter pylori; Utilizacao de micro dose de ureia com {sup 14} C no teste respiratorio para diagnosticar a presenca de Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Chausson, Yvon [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil); Coelho, Luiz Gonzaga V.; Passos, Maria do Carmo F.; Andrade, Angela A.M.; Simal, Carlos J.R.; Paula Castro, Luiz de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Hospital das Clinicas; Fernandes, M.L.; Yazaki, F.R. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Estatistica

    1995-12-31

    A lower dose is used in the {sup 14} C-urea breath test to detect the Helicobacter pylori (Hp). Such dose produce trivial radiation doses. The results shown that the use of this desirable dose is possible. (author). 4 refs., 1 fig.

  20. [Breath-analysis tests in gastroenetrological diagnosis].

    Science.gov (United States)

    Caspary, W F

    1975-12-01

    The introduction of a simple method for analysis of 14CO2 in breath allowed a more widely application of breath-tests in the diagnosis of gastroenterological diseases. During a breath-test a 14C-labelled compound is administered orally and 14CO2 is subsequently measured in breath by discontinuous samplings of 14CO2 by virtue of a trapping solution (hyamine hydroxide). Most helpful tests in gastroenterology are the 14C-glycyl-cholate breath test for detecting increased deconjugation of bile acids due to small intestinal bacterial overgrowth or bile acid malabsorption in ileal resection or Crohn's disease of the ileum, the 14C-lactose breath test in lactase deficiency, whereas the 14C-tripalmitin test seems less helpful in the diagnosis of fat malabsorption. A 14C-aminopyrine breath test may turn out to be a simple and valuable liver function test. Oral loading tests with breath analysis of H2 have shown to be helpful in the diagnosis of carbohydrate malabsorption, determination of intestinal transit time and intestinal gas production. Due to technical reasons (gas-chromatographie analysis) H2-breath analysis is still limited to research centers. Despite low radiation doses after oral administration of 14C-labelled compounds oral loading tests with H2- or 13C-analysis might be preferable in the future.

  1. Can Breath Test Detect Stomach Cancers Earlier?

    Science.gov (United States)

    ... news/fullstory_163342.html Can Breath Test Detect Stomach Cancers Earlier? New technology may also spot esophageal cancers ... the only way to diagnose esophageal cancer or stomach cancer is with endoscopy. This method is expensive, invasive ...

  2. Clinical Applications of CO2 and H2 Breath Test

    OpenAIRE

    ZHAO Si-qian; Chen, Bao-Jun; LUO Zhi-fu

    2016-01-01

    Breath test is non-invasive, high sensitivity and high specificity. In this article, CO2 breath test, H2 breath test and their clinical applications were elaborated. The main applications of CO2 breath test include helicobacter pylori test, liver function detection, gastric emptying test, insulin resistance test, pancreatic exocrine secretion test, etc. H2 breath test can be applied in the diagnosis of lactose malabsorption and detecting small intestinal bacterial overgrowth. With further res...

  3. Validation of a simplified carbon-14-urea breath test for routine use for detecting Helicobacter pylori noninvasively

    Energy Technology Data Exchange (ETDEWEB)

    Henze, E.; Malfertheiner, P.; Clausen, M.; Burkhardt, H.; Adam, W.E. (Univ. of Ulm (West Germany))

    1990-12-01

    A carbon-14 ({sup 14}C) urea breath test for detecting Helicobacter pylori with multiple breath sampling was developed. Carbon-14-urea (110 kBq) administered orally to 18 normal subjects and to 82 patients with Helicobacter infection. The exhaled {sup 14}C-labeled CO{sub 2} was trapped at 10-min intervals for 90 min. The total {sup 14}C activity exhaled over 90 min was integrated and expressed in %activity of the total dose given. In normals, a mean of 0.59% +/- 0.24% was measured, resulting in an upper limit of normal of 1.07%. In 82 patients, a sensitivity of 90.2%, a specificity of 83.8%, and a positive predictive value of 90.2% was found. The single probes at intervals of 40-60 min correlated best with the integrated result, with r ranging from 0.986 to 0.990. The test's diagnostic accuracy did not change at all when reevaluated with the 40-, 50-, or 60-min sample data alone. Thus, the {sup 14}C-urea breath test can be applied routinely as a noninvasive, low-cost and one-sample test with high diagnostic accuracy in detecting Helicobacter pylori colonization.

  4. 21 CFR 862.3080 - Breath nitric oxide test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath nitric oxide test system. 862.3080 Section... Systems § 862.3080 Breath nitric oxide test system. (a) Identification. A breath nitric oxide test system is a device intended to measure fractional nitric oxide in human breath. Measurement of changes...

  5. 42 CFR 84.88 - Breathing bag test.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bag test. 84.88 Section 84.88 Public... RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated...

  6. 42 CFR 84.91 - Breathing resistance test; exhalation.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing resistance test; exhalation. 84.91...-Contained Breathing Apparatus § 84.91 Breathing resistance test; exhalation. (a) Resistance to exhalation...-circuit apparatus with a breathing machine as described in § 84.88, and the exhalation resistance...

  7. Validity and cost comparison of "carbon urea breath test for diagnosis of H Pylori in dyspeptic patients

    Institute of Scientific and Technical Information of China (English)

    Shahid Rasool; Shahab Abid; Wasim Jafri

    2007-01-01

    AIM: To validate and compare the cost of microdose 14C urea breath test (UBT) with histology and rapid urease test for the diagnosis of H Pylori.METHODS: Ninety-four consecutive patients with dyspeptic symptoms undergoing gastroscopy were enrolled. Gastric biopsies were taken for histology and rapid urease test. UBT was performed after gastroscopy by microdose "C urea capsules. Sensitivity, specificity and accuracy of UBT were calculated and compared with histology and rapid urease test. Cost comparison of these tests was also performed.RESULTS: H pylori was diagnosed by histology and rapid urease test in 66 (70%) and 61 (65%) patients, while 14C UBT detected infection in 63 (67%). Accuracy of UBT was 93% in comparison with histology while its positive and negative predictive values were 97% and 84%, respectively. Comparison of 14C UBT with rapid urease test gives an accuracy of 96%, with positive and negative predictive values of 95% and 97%, respectively. These results were highly reproducible with a Kappa test (P value < 0.001). Cost of histology or rapid urease test with gastroscopy was 110 USD or 95 USD respectively while the cost of UBT was 15 USD.CONCLUSION: Microdose 14C UBT was comparable to histology and rapid urease test. 14C UBT is an economical, self sufficient and suitable test to diagnose active Hpylori infection in less developed countries.

  8. 42 CFR 84.90 - Breathing resistance test; inhalation.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing resistance test; inhalation. 84.90...-Contained Breathing Apparatus § 84.90 Breathing resistance test; inhalation. (a) Resistance to inhalation airflow will be measured in the facepiece or mouthpiece while the apparatus is operated by a...

  9. 42 CFR 84.122 - Breathing resistance test; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing resistance test; minimum requirements. 84... Masks § 84.122 Breathing resistance test; minimum requirements. (a) Resistance to airflow will be measured in the facepiece or mouthpiece of a gas mask mounted on a breathing machine both before and...

  10. 46 CFR 197.450 - Breathing gas tests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing gas tests. 197.450 Section 197.450 Shipping....450 Breathing gas tests. The diving supervisor shall insure that— (a) The output of each air... or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked...

  11. Follow up of serial urea breath test results in patients after consumption of antibiotics for non-gastric infections

    Institute of Scientific and Technical Information of China (English)

    Wai-Keung Leung; Lawrence Cheung-Tsui Hung; Carrie Ka-Li Kwok; Rupert Wing-Loong Leong; Daniel Kwok-Keung Ng; Joseph Jao-Yiu Sung

    2002-01-01

    AIM: The widespread use of antibacterial therapy hasbeen suggested to be the cause for the decline in theprevalence of Helicobacter pyloriinfection. This studyexamine the serial changes of urea breath test resultsin a group of hospitalized patients who were givenantibacterial therapy for non-gastric infections.METHODS: Thirty-five hospitalized patients who weregiven antibacterial therapy for clinical infections,predominantly chest and urinary infections, werestudied. Most (91%) patients were given singleantibiotic of either a penicillin or cephalosporin group.Serial 13C-urea breath tests were performed within 24hours of initiation of antibiotics, at one-week and atsix-week post-therapy. H. pylori infection wasdiagnosed when one or more urea breath tests waspositive.RESULTS: All 35 patients completed three serial ureabreath tests and 26 (74 %) were H. pylori-positive. Ten(38 %) H. pylori-infected patients had at least onenegative breath test results during the study period.The medium delta 13C values were significantly lowerat baseline (8.8) than at one-week (20.3) and six-week(24.5) post-treatment in H. pylori-positive individuals(P=0.022). Clearance of H. pyloriat six-week was onlyseen in one patient who had received anti-helicobactertherapy from another source.CONCLUSION: Our results suggested that one-third ofH. pylori-infected individuals had transient false-negative urea breath test results during treatment withantibacterial agent. However, clearance of H. pyloriinfection by regular antibiotic consumption is rare.

  12. 42 CFR 84.203 - Breathing resistance test; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing resistance test; minimum requirements. 84.203 Section 84.203 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Chemical Cartridge Respirators § 84.203 Breathing resistance test; minimum requirements. (a) Resistance...

  13. Breath testing and personal exposure--SIFT-MS detection of breath acetonitrile for exposure monitoring.

    Science.gov (United States)

    Storer, Malina; Curry, Kirsty; Squire, Marie; Kingham, Simon; Epton, Michael

    2015-05-26

    Breath testing has potential for the rapid assessment of the source and impact of exposure to air pollutants. During the development of a breath test for acetonitrile using selected ion flow tube mass spectrometry (SIFT-MS) raised acetonitrile concentrations in the breath of volunteers were observed that could not be explained by known sources of exposure. Workplace/laboratory exposure to acetonitrile was proposed since this was common to the volunteers with increased breath concentrations. SIFT-MS measurements of acetonitrile in breath and air were used to confirm that an academic chemistry laboratory was the source of exposure to acetonitrile, and quantify the changes that occurred to exhaled acetonitrile after exposure. High concentrations of acetonitrile were detected in the air of the chemistry laboratory. However, concentrations in the offices were not significantly different across the campus. There was a significant difference in the exhaled acetonitrile concentrations of people who worked in the chemistry laboratories (exposed) and those who did not (non-exposed). SIFT-MS testing of air and breath made it possible to determine that occupational exposure to acetonitrile in the chemistry laboratory was the cause of increased exhaled acetonitrile. Additionally, the sensitivity was adequate to measure the changes to exhaled amounts and found that breath concentrations increased quickly with short exposure and remained increased even after periods of non-exposure. There is potential to add acetonitrile to a suite of VOCs to investigate source and impact of poor air quality.

  14. The Influence of Age on Interaction between Breath-Holding Test and Single-Breath Carbon Dioxide Test.

    Science.gov (United States)

    Trembach, Nikita; Zabolotskikh, Igor

    2017-01-01

    Introduction. The aim of the study was to compare the breath-holding test and single-breath carbon dioxide test in evaluation of the peripheral chemoreflex sensitivity to carbon dioxide in healthy subjects of different age. Methods. The study involved 47 healthy volunteers between ages of 25 and 85 years. All participants were divided into 4 groups according to age: 25 to 44 years (n = 14), 45 to 60 years (n = 13), 60 to 75 years (n = 12), and older than 75 years (n = 8). Breath-holding test was performed in the morning before breakfast. The single-breath carbon dioxide (SB-CO2) test was performed the following day. Results. No correlation was found between age and duration of breath-holding (r = 0.13) and between age and peripheral chemoreflex sensitivity to CO2 (r = 0.07). In all age groups there were no significant differences in the mean values from the breath-holding test and peripheral chemoreflex sensitivity tests. In all groups there was a strong significant inverse correlation between breath-holding test and SB-CO2 test. Conclusion. A breath-holding test reflects the sensitivity of the peripheral chemoreflex to carbon dioxide in healthy elderly humans. Increasing age alone does not alter the peripheral ventilatory response to hypercapnia.

  15. 13C-urea and15N2-urea : Elegant markers to define location and kinetics of in vivo release from a colon-targeted delivery device in men

    NARCIS (Netherlands)

    Schellekens, R.C.A.; Olsder, G.; Maurer, M.; Kosterink, J.; Woerdenbach, H.J.; Wutzke, K.D.; Frijlink, H.W.; Stellaard, F.

    2010-01-01

    Background:13C-urea may be a suitable marker to assess the in vivo fate of colon-targeted dosage forms given by mouth. Release in the colon would lead to fermentation of13C-urea into13CO2and excretion of13CO2in breath, release in the small intestine to detection of13C-urea in blood and urine. The di

  16. 42 CFR 84.152 - Breathing tube test; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... Respirators § 84.152 Breathing tube test; minimum requirements. (a)(1) Type A and Type B supplied-air respirators shall employ one or two flexible breathing tubes of the nonkinking type which extend from the... employed on Type C supplied-air respirators of the continuous flow class shall meet the...

  17. Hydrogen and methane breath tests for evaluation of resistant carbohydrates

    DEFF Research Database (Denmark)

    Rumessen, J J

    1992-01-01

    This review considers in detail the background, principles, techniques, limitations and advantages of the hydrogen and methane breath tests. Resistant food carbohydrates, defined as dietary carbohydrates partly or totally escaping small intestinal assimilation, are fermented in the human colon...... carbohydrates. Methane breath tests may supplement the information gained from hydrogen measurements, but further evaluations are needed. The hydrogen breath technique is rapid, simple and non-invasive as well as non-radioactive. It may be carried out in a large number of intact individuals under physiological...

  18. Breathing simulator of workers for respirator performance test.

    Science.gov (United States)

    Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio

    2015-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.

  19. A Systematic Approach to Multiple Breath Nitrogen Washout Test Quality

    Science.gov (United States)

    Klingel, Michelle; Pizarro, Maria Ester; Hall, Graham L.; Ramsey, Kathryn; Foong, Rachel; Saunders, Clare; Robinson, Paul D.; Webster, Hailey; Hardaker, Kate; Kane, Mica; Ratjen, Felix

    2016-01-01

    Background Accurate estimates of multiple breath washout (MBW) outcomes require correct operation of the device, appropriate distraction of the subject to ensure they breathe in a manner representative of their relaxed tidal breathing pattern, and appropriate interpretation of the acquired data. Based on available recommendations for an acceptable MBW test, we aimed to develop a protocol to systematically evaluate MBW measurements based on these criteria. Methods 50 MBW test occasions were systematically reviewed for technical elements and whether the breathing pattern was representative of relaxed tidal breathing by an experienced MBW operator. The impact of qualitative and quantitative criteria on inter-observer agreement was assessed across eight MBW operators (n = 20 test occasions, compared using a Kappa statistic). Results Using qualitative criteria, 46/168 trials were rejected: 16.6% were technically unacceptable and 10.7% were excluded due to inappropriate breathing pattern. Reviewer agreement was good using qualitative criteria and further improved with quantitative criteria from (κ = 0.53–0.83%) to (κ 0.73–0.97%), but at the cost of exclusion of further test occasions in this retrospective data analysis. Conclusions The application of the systematic review improved inter-observer agreement but did not affect reported MBW outcomes. PMID:27304432

  20. A Systematic Approach to Multiple Breath Nitrogen Washout Test Quality.

    Directory of Open Access Journals (Sweden)

    Renee Jensen

    Full Text Available Accurate estimates of multiple breath washout (MBW outcomes require correct operation of the device, appropriate distraction of the subject to ensure they breathe in a manner representative of their relaxed tidal breathing pattern, and appropriate interpretation of the acquired data. Based on available recommendations for an acceptable MBW test, we aimed to develop a protocol to systematically evaluate MBW measurements based on these criteria.50 MBW test occasions were systematically reviewed for technical elements and whether the breathing pattern was representative of relaxed tidal breathing by an experienced MBW operator. The impact of qualitative and quantitative criteria on inter-observer agreement was assessed across eight MBW operators (n = 20 test occasions, compared using a Kappa statistic.Using qualitative criteria, 46/168 trials were rejected: 16.6% were technically unacceptable and 10.7% were excluded due to inappropriate breathing pattern. Reviewer agreement was good using qualitative criteria and further improved with quantitative criteria from (κ = 0.53-0.83% to (κ 0.73-0.97%, but at the cost of exclusion of further test occasions in this retrospective data analysis.The application of the systematic review improved inter-observer agreement but did not affect reported MBW outcomes.

  1. Data Mining Techniques Applied to Hydrogen Lactose Breath Test

    Science.gov (United States)

    Nepomuceno-Chamorro, Isabel; Pontes-Balanza, Beatriz; Hernández-Mendoza, Yoedusvany; Rodríguez-Herrera, Alfonso

    2017-01-01

    In this work, we present the results of applying data mining techniques to hydrogen breath test data. Disposal of H2 gas is of utmost relevance to maintain efficient microbial fermentation processes. Objectives Analyze a set of data of hydrogen breath tests by use of data mining tools. Identify new patterns of H2 production. Methods Hydrogen breath tests data sets as well as k-means clustering as the data mining technique to a dataset of 2571 patients. Results Six different patterns have been extracted upon analysis of the hydrogen breath test data. We have also shown the relevance of each of the samples taken throughout the test. Conclusions Analysis of the hydrogen breath test data sets using data mining techniques has identified new patterns of hydrogen generation upon lactose absorption. We can see the potential of application of data mining techniques to clinical data sets. These results offer promising data for future research on the relations between gut microbiota produced hydrogen and its link to clinical symptoms. PMID:28125620

  2. A Proof of Concept Study to Detect Urease Producing Bacteria in Lungs Using Aerosolized 13C-Urea

    Science.gov (United States)

    Timmins, Graham; Davies, Lea; Heynekamp, Theresa; Harkins, Michelle; Sharp, Zachary D.; Kelly, H. William

    2016-01-01

    This is a “proof of concept” study to determine whether inhalation of 13C-urea can be safely used to detect the presence of urease producing bacteria in the airways of patients with cystic fibrosis (CF) by detecting 13CO2 in breath. This was a prospective, 2-part, open label, single-center, single-arm, single-administration, dose-escalation investigational device exemption trial. First, the safety of 20 and 50 mg inhaled 13C-urea was evaluated in 6 healthy adult participants. Then, 3 adult CF participants colonized with Pseudomonas aeruginosa were enrolled for each dose of inhaled 13C-urea. The safety of inhaled 13C-urea was assessed by spirometry and physical examination. 13C-urea was administered using a jet nebulizer, followed by serial spirometry (10 min and 30 min post inhalation) and collection of exhaled breath at 5, 10, and 15 min post inhalation. There was no clinical significant change in any of the spirometry values compared to baseline in healthy participants and CF patients. Mean of 13CO2/12CO2 delta over baseline (DOB) values in CF participants at 5, 10, and 15 min post inhalation was as follows: 20 mg dose 4‰ (2.2‰–4.9‰), 1‰ (1.0‰–1.4‰), and 1‰ (0.4‰–1.5‰); 50 mg dose: 10‰ (6.2‰–14.5‰), 3‰ (2.1‰–4.3‰), and 1.5‰ (0.6‰–2.3‰). Inhaled 13C-urea for detection of urease producing bacteria was safe, and preliminary data suggest that 13CO2/12CO2 DOB values may be higher in CF patients with P. aeruginosa at 5–10 min after inhalation of 13C-urea. A future direction is to investigate use of inhaled 13C-urea in young children who have difficulty producing sputum for culturing. PMID:27458537

  3. Biokinetics and radiation doses for carbon-14 urea in adults and children undergoing the Helicobacter pylori breath test

    Energy Technology Data Exchange (ETDEWEB)

    Leide-Svegborn, S.; Olofsson, M.; Mattsson, S.; Nosslin, B.; Pau, K. [Department of Radiation Physics, Lund University, Malmoe University Hospital, Malmoe (Sweden); Stenstroem, K.; Erlandsson, B.; Hellborg, R. [Department of Nuclear Physics, Lund University, Lund (Sweden); Nilsson, L. [Department of Clinical Physiology, Lund University, Malmoe University Hospital, Malmoe (Sweden); Johansson, L. [Department of Radiation Physics, Umeaa University, Umeaa University Hospital, Umeaa (Sweden); Skog, G. [Radiocarbon Dating Laboratory, Department of Quaternary Geology, Lund University, Lund (Sweden)

    1999-06-01

    The long-term biokinetics and dosimetry of carbon-14 were studied in nine adults and eight children undergoing carbon-14 urea breath test for Helicobacter pylori (HP) infection. The elimination of {sup 14}C via exhaled air and urine was measured with the liquid scintillation counting technique and with accelerator mass spectrometry. After the subjects had been given 110 kBq {sup 14}C-urea (children: 55 kBq) orally, samples of exhaled air were taken up to 180 days after administration and samples of urine were collected up to 40 days. Sixteen of the subjects were found to be HP-negative. In these subjects a total of 91.1%{+-}3.9% (mean of adults and children {+-} standard error of the mean) of the administered {sup 14}C activity was recovered. The majority of the administered activity, 88.3%{+-}6.2% in adults and 87.7%{+-}5.0% in children, was excreted via the urine within 72 h after administration. A smaller fraction was exhaled. In adults 4.6%{+-}0.6% of the activity was exhaled within 20 days and in children 2.6%{+-}0.3%. Uncertainties in the biokinetic results are mainly due to assumptions concerning endogenous CO{sub 2} production and urinary excretion rate and are estimated to be less than 30%. The absorbed dose to various organs and the effective dose were calculated using the ICRP model for urea and CO{sub 2}. The urinary bladder received the highest absorbed dose: in adults, 0.15{+-}0.01 mGy/MBq and in children of various ages (7-14 years), 0.14-0.36 mGy/MBq. The findings indicate that an investigation with {sup 14}C-urea gives an effective dose to adults of 2.1{+-}0.1 {mu}Sv (for 110 kBq) and to children of 0.9-2.5 {mu}Sv (for 55 kBq). From a radiation protection point of view, there is thus no reason for restrictions on even repeated screening investigations with {sup 14}C-urea in whole families, including children. (orig.) With 5 figs., 4 tabs., 32 refs.

  4. Dual therapy for third-line Helicobacter pylori eradication and urea breath test prediction

    Institute of Scientific and Technical Information of China (English)

    Toshihiro Nishizawa; Hidekazu Suzuki; Takama Maekawa; Naohiko Harada; Tatsuya Toyokawa; Toshio Kuwai; Masanori Ohara

    2012-01-01

    We evaluated the efficacy and tolerability of a dual therapy with rabeprazole and amoxicillin (AMX) as an empiric third-line rescue therapy.In patients with failure of first-line treatment with a proton pump inhibitor (PPI)-AMX-clarithromycin regimen and second-line treatment with the PPI-AMX-metronidazole regimen,a third-line eradication regimen with mbeprazole (10 mg q.i.d.) and AMX (500 mg q.i.d.) was prescribed for 2 wk.Eradication was confirmed by the results of the 13C-urea breath test (UBT) at 12 wk after the therapy.A total of 46 patients were included; however,two were lost to followup.The eradication rates as determined by per-protocol and intention-to-treat analyses were 65.9% and 63.0%,respectively.The pretreatment UBT results in the subjects showing eradication failure; those patients showing successful eradication comprised 32.9 ± 28.8 permil and 14.8 ± 12.8 permil,respectively.The pretreatment UBT results in the subjects with eradication failure were significantly higher than those in the patients with successful eradication (P =0.019).A low pretreatment UBT result (≤ 28.5 permil) predicted the success of the eradication therapy with a positive predictive value of 81.3% and a sensitivity of 89.7%.Adverse effects were reported in 18.2% of the patients,mainly diarrhea and stomatitis.Dual therapy with rabeprazole and AMX appears to serve as a potential empirical third-line strategy for patients with low values on pretreatment UBT.

  5. 21 CFR 862.3050 - Breath-alcohol test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... diagnosis of alcohol intoxication. (b) Classification. Class I....

  6. Development of Synthetic Methods of Breath Test Drug Carbon Labeled Methacetin

    Institute of Scientific and Technical Information of China (English)

    ZHAO; Si-qian; CHEN; Bao-jun; LUO; Zhi-fu

    2013-01-01

    The accurate detection of liver function has important clinical significance.Breath test,due to it’s many advantages such as noninvasive,simple as well as good accuracy when applied to liver function test,has been deeply researched and applied in clinic.There are some common breath tests to reflect hepatocyte microsome function:Aminopyrine breath

  7. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices...

  8. Biokinetics and radiation dosimetry of {sup 14}C-labelled triolein, urea, glycocholic acid and xylose in man. Studies related to nuclear medicine 'breath tests' using accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Gunnarsson, Mikael

    2002-08-01

    {sup 14}C-labelled substances have been used in biomedical research and clinical medicine for over 50 years. Physicians and scientists however, often hesitate to use these substances in patients and volunteers because the radiation dosimetry is unclear. In this work detailed long-term biokinetic and dosimetric estimation have been carried out for four clinically used {sup 14}C-breath tests: {sup 14}C-triolein (examination of fat malabsorption), urea (detection of Helicobacter pylori infection in the stomach), glycocholic acid and xylose (examination of bacterial overgrowth in the small intestine) by using the highly sensitive accelerator mass-spectrometry (AMS) technique. The AMS technique has been used to measure low {sup 14}C concentrations in small samples of exhaled air, urine, faeces and tissue samples and has improved the base for the estimation of the absorbed dose to various organs and tissues and the effective dose to man. The high sensitivity of the AMS system has also made it possible to perform {sup 14}C breath tests on patient groups which were earlier subject for restriction (e.g. small children). In summary, our results show that for adult patients - and in the case of {sup 14}C-urea breath test also for children down to 3 years of age - the dose contributions are comparatively low, both described as organ doses and as effective doses. For adults, the latter is: {sup 14}C-glycocholic acid - 0.4 mSv/MBq, {sup 14}C-triolein - 0.3 mSv/MBq, {sup 14}C-xylose - 0.1 mSv/MBq and {sup 14}C-urea - 0.04 mSv/MBq. Thus, from a radiation protection point of view there is no reason for restrictions in using any of the {sup 14}C-labelled radiopharmaceutical included in this work in the activities normally used (0.07-0.2 MBq for a 70 kg patient)

  9. 13C-methacetin breath test parameter S for liver diseases diagnosis

    Institute of Scientific and Technical Information of China (English)

    曾文炳; 张维成; 许士元; 杨志忠; 刘纯; 朱德平; 文启彬; 申岐祥; 王先彬

    1996-01-01

    The mechanism of 13C-methacetin breath test is set forth clearly with the analysis of pharmacokinetics mode, and the measuring method of 13C-methacetin breath test and its clinical applications in the diagnosis of liver diseases are reported in detail. On the basis of comprehensive analysis of the clinical test data, the advanced diagnostic parameter S is of important significance for the application and development of breath test.

  10. Aspiration tests in aqueous foam using a breathing simulator

    Energy Technology Data Exchange (ETDEWEB)

    Archuleta, M.M.

    1995-12-01

    Non-toxic aqueous foams are being developed by Sandia National Laboratories (SNL) for the National Institute of Justice (NIJ) for use in crowd control, cell extractions, and group disturbances in the criminal justice prison systems. The potential for aspiration of aqueous foam during its use and the resulting adverse effects associated with complete immersion in aqueous foam is of major concern to the NIJ when examining the effectiveness and safety of using this technology as a Less-Than-Lethal weapon. This preliminary study was designed to evaluate the maximum quantity of foam that might be aspirated by an individual following total immersion in an SNL-developed aqueous foam. A.T.W. Reed Breathing simulator equipped with a 622 Silverman cam was used to simulate the aspiration of an ammonium laureth sulfate aqueous foam developed by SNL and generated at expansion ratios in the range of 500:1 to 1000:1. Although the natural instinct of an individual immersed in foam is to cover their nose and mouth with a hand or cloth, thus breaking the bubbles and decreasing the potential for aspiration, this study was performed to examine a worst case scenario where mouth breathing only was examined, and no attempt was made to block foam entry into the breathing port. Two breathing rates were examined: one that simulated a sedentary individual with a mean breathing rate of 6.27 breaths/minute, and one that simulated an agitated or heavily breathing individual with a mean breathing rate of 23.7 breaths/minute. The results of this study indicate that, if breathing in aqueous foam without movement, an air pocket forms around the nose and mouth within one minute of immersion.

  11. Lactose malabsorption during gastroenteritis, assessed by the hydrogen breath test.

    OpenAIRE

    Gardiner, A J; Tarlow, M J; Sutherland, I T; Sammons, H G

    1981-01-01

    Thirty-eight infants and young children with gastroenteritis were investigated for lactose malabsorption. Each of them was given an oral lactose load of either 0.5 g/kg or 2 g/kg after which breath hydrogen excretion was measured, and each was observed to see if he had clinical symptoms of lactose intolerance. Only one patient, given 2 g/kg lactose, had clinical intolerance. His breath hydrogen excretion however was negative. Three of 18 patients given 0.5 g/kg lactose had positive breath hyd...

  12. Accuracy of a rapid 10-minute carbon-14 urea breath test for the diagnosis of Helicobacter pylori-associated peptic ulcer disease

    Energy Technology Data Exchange (ETDEWEB)

    Kao Chiahung (Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine); Wang Shyhjen (Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine); Hsu Chungyuan (Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine); Lin Wanyu (Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine); Huang Chihkua (Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Gastroenterology); Chen Granhum (Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Gastroenterology)

    1993-08-01

    Urease in the human gastric mucosa is a marker for infection with Helicobacter pylori (HP), an organism which is associated with peptic ulcer disease. To detect gastric urease, we examined 184 patients (144 males, 40 females; mean age: 49.8[+-]15.6 years) with suspected peptic ulcer disease. Fasting patients were given orally 5 [mu]Ci of carbon-14 labelled urea. For each patient only one breath sample was collected in hyamine at 10 min. The amount of [sup 14]C collected at 10 min was expressed as follows: (DPM/mmol CO[sub 2] collected)/(DPM administered)x100xbody weight (kg). The presence of HP colonization was determined by examination of multiple endoscopic prepyloric antral biopsy specimens subjected to culture or a rapid urease test. For the purpose of this study, HP-positive patients were defined as those with characteristic bacteria as indicated by a positive result of either the culture or the rapid urease test; HP-negative patients were defined as those with negative findings on both the culture and the rapid urease test. Of the 184 cases, 99 (53.8%) were positive for HP infection, and 85 (46.2%), negative. The sensitivity and specificity of the rapid 10 min [sup 14]C-urea breath test for the diagnosis of HP-associated peptic ulcer disease were evaluated by a receiver operating characteristic (ROC) curve with a variable cut-off value from 1.5 to 4.5. When a cut-off value of 1.5 was selected, the sensitivity was 100% and the specificity, 83.5%; when a cut-off value of 4.5 was selected, the sensitivity was 54.5% and the specificity, 97.6%. (orig.)

  13. Breath hydrogen test in infants and children with blind loop syndrome.

    Science.gov (United States)

    Nose, O; Kai, H; Harada, T; Ogawa, M; Maki, I; Tajiri, H; Kanaya, S; Kimura, S; Shimizu, K; Yabuuchi, H

    1984-06-01

    Breath hydrogen production after oral lactose loading was examined in infants and children with stagnant loop syndrome, blind loop syndrome, or both. All six infants under 3 years of age had bacteriological evidence of small intestinal colonization. The characteristics of the breath hydrogen test in this syndrome are: (a) extremely high basal excretion of breath hydrogen (after overnight fasting); (b) an earlier and greater breath hydrogen value (0.293 +/- 0.201 ml/min/m2: mean +/- SD) after oral lactose administration than formed in lactose malabsorption alone (0.050 +/- 0.041 ml/min/m2); and (c) the observation of a sustained hydrogen rise over several hours. This investigation demonstrated that the breath hydrogen test is a promising and noninvasive tool for diagnosing blind (or stagnant) loop syndrome.

  14. Urease-positive bacteria in the stomach induce a false-positive reaction in a urea breath test for diagnosis of Helicobacter pylori infection.

    Science.gov (United States)

    Osaki, Takako; Mabe, Katsuhiro; Hanawa, Tomoko; Kamiya, Shigeru

    2008-07-01

    This study investigated the influence of urease-positive non-Helicobacter pylori bacteria on the results of a urea breath test (UBT) to evaluate the diagnostic utility of a UBT using film-coated [(13)C]urea tablets. The UBT was performed in 102 patients treated with a proton pump inhibitor and antibiotics for the eradication of H. pylori. Urease-producing bacteria other than H. pylori were isolated and identified from the oral cavity and stomach. In 4/102 patients, the UBT gave false-positive results. These false-positive results were found to be caused by the presence of urease-positive bacteria in the oral cavity and stomach. Five bacterial species with urease activity (Proteus mirabilis, Citrobacter freundii, Klebsiella pneumoniae, Enterobacter cloacae and Staphylococcus aureus) were subsequently isolated from the oral cavity and/or stomach. As there was no correlation between the in vitro urease activity of urease-positive non-H. pylori bacteria and the UBT value, and all of the patients with a false-positive UBT result were suffering from atrophic gastritis, it is possible that the false-positive results in the UBT were a result of colonization of urease-positive bacteria and gastric hypochlorhydric conditions. Thus, for the diagnosis of H. pylori infection using a UBT, the influence of stomach bacteria must be considered when interpreting the results.

  15. Pre-treatment urea breath test results predict the efficacy of Helicobacter pylori eradication therapy in patients with active duodenal ulcers

    Institute of Scientific and Technical Information of China (English)

    Yung-Chih Lai; Jyh-Chin Yang; Shih-Hung Huang

    2004-01-01

    AIM: To evaluate the association of pre-treatment 13C-urea breath test (UBT) results with H pyloridensity and efficacy of eradication therapy in patients with active duodenal ulcers.METHODS: One hundred and seventeen consecutive outpatients with active duodenal ulcer and H pyloriinfection were recruited. H pylori density was histologically graded according to the Sydney system. Each patient received lansoprazole (30 mg b.i.d.), clarithromycin (500 mg b.i.d.) and amoxicillin (1 g b.i.d.) for 1 week. According to pre-treatment UBT values, patients were allocated into low (<16%o),intermediate (16-35%o), and high (>35%o) UBT groups.RESULTS: A significant correlation was found between pre-treatment UBT results andHpyloridensity (P<0.001).H pylorieradication rates were 94.9%, 94.4% and 81.6%in the low, intermediate and high UBT groups, respectively (per protocol analysis, P=0.11). When patients were assigned into two groups (UBT results ≤35%o and >35%o),the eradication rates were 94.7% and 81.6%, respectively (P=0.04).CONCLUSION: The intragastric bacterial load of H pylori can be evaluated by UBT, and high pre-treatment UBT results can predict an adverse outcome of eradication therapy.

  16. The Effects of Gastroesophageal Reflux Disease on Forensic Breath Alcohol Testing.

    Science.gov (United States)

    Booker, James L; Renfroe, Kathryn

    2015-11-01

    Fifteen test subjects, 10 of whom were diagnosed with gastroesophageal reflux disease (GERD), were dosed with alcohol to BACs above 0.150 g/dL. Blood and breath assays taken at 20-min intervals for 8 h after dosing demonstrated close agreement between postabsorptive BAC and BrAC values. Three subjects exhibited elevated breath alcohol concentrations up to 0.105 g/dL during the absorptive phase that were apparently due to the passage of gastric alcohol through the lower esophageal sphincter not attributable to eruction or regurgitation. The effect of gastric alcohol was not consistently proportional to the amount of unabsorbed gastric alcohol. Absorption of alcohol in the esophagus explains the nonproportionality. Breath samples contaminated by GERD-related alcohol leakage from the stomach into a breath sample were found only when there was a high concentration of alcohol in the stomach. When contaminated breath samples were encountered, they were irreproducible in magnitude.

  17. Critical appraisal of 13C breath tests for microsomal liver function: aminopyrine revisited.

    Science.gov (United States)

    Pijls, Kirsten E; de Vries, Hanne; Nikkessen, Suzan; Bast, Aalt; Wodzig, Will K W H; Koek, Ger H

    2014-04-01

    As liver diseases are a major health problem and especially the incidence of metabolic liver diseases like non-alcoholic fatty liver disease (NAFLD) is rising, the demand for non-invasive tests is growing to replace liver biopsy. Non-invasive tests such as carbon-labelled breath tests can provide a valuable contribution to the evaluation of metabolic liver function. This review aims to critically appraise the value of the (13) C-labelled microsomal breath tests for the evaluation of metabolic liver function, and to discuss the role of cytochrome P450 enzymes in the metabolism of the different probe drugs, especially of aminopyrine. Although a number of different probe drugs have been used in breath tests, the perfect drug to assess the functional metabolic capacity of the liver has not been found. Data suggest that both the (13) C(2) -aminopyrine and the (13) C-methacetin breath test can play a role in assessing the capacity of the microsomal liver function and may be useful in the follow-up of patients with chronic liver diseases. Furthermore, CYP2C19 seems to be an important enzyme in the N-demethylation of aminopyrine, and polymorphisms in this gene may influence breath test values, which should be kept in mind when performing the (13) C(2) -aminopyrine breath test in clinical practice.

  18. Potential effect of alcohol content in energy drinks on breath alcohol testing.

    Science.gov (United States)

    Lutmer, Brian; Zurfluh, Carol; Long, Christopher

    2009-04-01

    Since the advent of energy drinks in the U.S. marketplace, some defendants have claimed that positive breath alcohol test results have occurred due to the ingestion of non-alcoholic energy drinks. A variety of energy drinks were tested by gas chromatography and some 88.9% (24 of 27) were found to contain low concentrations of ethanol (5-230 mg/dL). Drinks were then consumed (24.6-32 oz) by volunteers to determine the extent of reaction that could be achieved on a portable breath-testing instrument. Eleven of 27 (40.7%) beverages gave positive results on a portable breath-testing instrument (0.006-0.015 g/210 L) when samples were taken within 1 min of the end of drinking. All tests taken by portable breath test, DataMaster, and Intox EC/IR II at least 15 min after the end of drinking resulted in alcohol-free readings (0.000 g/210 L). Affording subjects a minimum 15-min observation period prior to breath-alcohol testing eliminates the possibility that a small false-positive alcohol reading will be obtained.

  19. Breath and string test: A diagnostic package for the identification of treatment failure and antibiotic resistance of Helicobacter pylori without the necessity of upper gastrointestinal endoscopy

    Institute of Scientific and Technical Information of China (English)

    Andreas Leodolter; Kathlen Wolle; Ulrike von Arnim; Stefan Kahl; Gerhard Treiber; Matthias P. Ebert; Ulrich Peitz; Peter Malfertheiner

    2005-01-01

    AIM: Helicobacter pylori ( H pylofi) resistance after failed eradication has a major impact on the outcome of a further treatment regimen. The aim of this study was to assess the validity of a non-invasive strategy using the 13C-urea breath test (UBT) and the gastric string test in identifying post-treatment resistance of Hpylori.METHODS: The UBT was routinely performed 4 to 6 wk after H pylorieradication therapy. Forty-two patients (24 females, 18 males, mean age 48 years) with a positive UBT were included in the study. A gastric string test using a capsule containing a 90 cm-long nylon fiber was performed.Before the capsule was swallowed, the free end of the string was taped to the cheek. After one hour in the stomach, the string was withdrawn. The distal 20 cm of the string was inoculated onto an agar plate and processed under microaerophilic conditions. Following the string test, upper gastrointestinal endoscopy was performed to obtain gastric biopsies for conventional culture.RESULTS: H pyloriwas successfully cultured from the gastric string in 34 patients (81%), but not in 5 patients due to contamination with oropharyngeal flora. Hpyloriwas cultured from the gastric biopsies obtained at endoscopy in 39 patients (93%).CONCLUSION: The UBT followed by the gastric string test in the case of treatment failure is a valid diagnostic strategy with the aim of determining the post-therapeutic antibiotic resistance of Hpyloriwith little inconvenience to the patient.Upper GI-endoscopy can be avoided in several cases by applying consequently this diagnostic package.

  20. Fructose breath hydrogen test--is it really a harmless diagnostic procedure?

    Science.gov (United States)

    Müller, P; Meier, C; Böhme, H J; Richter, T

    2003-01-01

    Usage of hydrogen breath tests has become one of the standard procedures in diagnosing chronic unspecific abdominal pain. These tests are said to be of sufficient specificity and sensitivity, are easily done, non-invasive and are more often practiced in outpatients. A 13-year-old boy is reported with chronic unspecific abdominal pain and growth retardation and so far misdiagnosed hereditary fructose intolerance (HFI), who developed life-threatening adverse effects during the fructose breath hydrogen test. It is concluded that the possibility of HFI should be excluded first by a carefully explored dietary history before the fructose breath test is performed under medical supervision. If there is any suspicion of HFI, a molecular genetic analysis should be preferred.

  1. Ten years experience of isotopic breath test with special reference to Helicobacter pylori detection

    Energy Technology Data Exchange (ETDEWEB)

    Verhas, M.; Tricht, L.Van; Verschaeren, A.; Delmotte, E.; Martin, P

    1997-12-31

    The use of the carbon 14 urea breath test by comparison with culture for campylobacter of gastric endoscopic biopsies is studied in 91 patients. They were divided into 2 groups. The first group consisted of 53 patients examined by gastric endoscopy and carbon 14 urea breath test. In this population, gastric biopsies were taken at different regions of the stomach and duodenum. The breath test was performed within 3 hours after endoscopy. The second group consisted of 38 asymptomatic patients whom 23 were parent of children with campylobacter positive gastritis. For the whole population, neither antibiotic therapy nor bismuth medication was administrated within the 15 days before the realization of the test. Results were expressed in % of injected dose/mmole of CO{sub 2} after correction of endogenous production of CO{sub 2}. In conclusion, carbon 14 urea breath test is a reliable noninvasive test for detection and follow-up of gastritis caused by a widespread microorganism. Also, the precision of both tests, {sup 14} C-UBT and {sup 13} C-UBT, are compared simultaneously in 84 adults patients. The results were expressed as % of administered dose expired in 30 minutes. A better precision is observed with the {sup 13} C-UBT

  2. FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests

    Science.gov (United States)

    Sukul, Pritam; Schubert, Jochen K.; Oertel, Peter; Kamysek, Svend; Taunk, Khushman; Trefz, Phillip; Miekisch, Wolfram

    2016-06-01

    Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.

  3. Dosimetry and reproducibility of a capsule-based C-14 urea breath test

    Energy Technology Data Exchange (ETDEWEB)

    Combs, M.J.; Stubbs, J.B.; Buck, D.A. [Univ. of Virginia, Charlottesville, VA (United States)]|[Oak Ridge Inst. for Science and Education, TN (United States)] [and others

    1995-05-01

    The aims of this study were (1) to determine the excretion of the C-14 and associated radiation dose and (2) to examine the reproducibility of a commercial C-14 urea breath test for H.pylori diagnosis. Tests were performed on twenty consenting volunteers (13M, 7F, 24-48 yr). Breath samples containing 1 mmol CO{sub 2} were obtained at 0,5,10,15,20,25,30 min. and 1,2,3,4,5,6,12, 24 hrs following administration of the 37kBq C-14 urea test capsule. A 24 hr urine collection was performed with each voiding collected separately. A repeat breath test was performed 24 hr after the first. H. pylori positive (HP+) was defined as a 15 minute breath sample >=50 dpm. Total urine excretion was obtained directly. Breath excretion was modeled by estimating the area under the excretion curve and using a constant factor of 884 mmol CO{sub 2}/ hr. Urine and breath excretion data in HP+ and H. pylori-negative (HP-) volunteers were pooled and fit to a monoexponential function thus estimating the cumulative urinary excretion of unmetabolized urea. Previously reported biokinetic models of C-14 urea and bicarbonate were used to estimate radiation doses form each compound. Weighted sums were calculated for each dose estimate using each group`s excretion fraction distribution. Both HP+ and HP- volunteers excreted an average of 73% of the C-14 over the first 24 hr. HP+ excretion was evenly divided between breath (34%) and urine (38%). HP-excretion is almost solely by the urinary pathway. The maximum dose for HP= was to the red marrow (0.0033 mGy) and a maximum of 0.0054 mGy to the urinary bladder wall for HP-. There was no difference between 15 inch breath samples on the two days (t-test, p>0.6). The minimum HP+ result at 15 inch was 270 dpm and the maximum HP- result at 15 inch was 18 dpm, indicating great separation between HP+ and HP- results. This study verifies previous dose estimates using C-14 excretion data. The test is sensitive and reproducible with a low radiation dose.

  4. Additional Value of CH₄ Measurement in a Combined (13)C/H₂ Lactose Malabsorption Breath Test: A Retrospective Analysis.

    Science.gov (United States)

    Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin

    2015-09-07

    The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H₂) excretion after an oral dose of lactose. We use a combined (13)C/H₂ lactose breath test that measures breath (13)CO₂ as a measure of lactose digestion in addition to H₂ and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 (13)C/H₂ lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH₄ in addition to H₂ and (13)CO₂. Based on the (13)C/H₂ breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH₄ further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H₂-excretion were found to excrete CH₄. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH₄-concentrations has an added value to the (13)C/H₂ breath test to identify methanogenic subjects with lactose malabsorption or SIBO.

  5. Comparison of the analytical capabilities of the BAC Datamaster and Datamaster DMT forensic breath testing devices.

    Science.gov (United States)

    Glinn, Michele; Adatsi, Felix; Curtis, Perry

    2011-11-01

    The State of Michigan uses the Datamaster as an evidential breath testing device. The newest version, the DMT, will replace current instruments in the field as they are retired from service. The Michigan State Police conducted comparison studies to test the analytical properties of the new instrument and to evaluate its response to conditions commonly cited in court defenses. The effects of mouth alcohol, objects in the mouth, and radiofrequency interference on paired samples from drinking subjects were assessed on the DMT. The effects of sample duration and chemical interferents were assessed on both instruments, using drinking subjects and wet-bath simulators, respectively. Our testing shows that Datamaster and DMT results are essentially identical; the DMT gave accurate readings as compared with measurements made using simulators containing standard ethanol solutions and that the DMT did not give falsely elevated breath alcohol results from any of the influences tested.

  6. [The clinical application of 13C-breath tests in pancreatic diseases].

    Science.gov (United States)

    Cherniavskiĭ, V V

    2014-11-01

    Maldigestion persists in most patients with chronic pancreatitis (GP). The objective lipase and amylase insufficiency diagnosis is needed to achieve an adequate clinical response to oral pancreatic enzyme substitution therapy. The novel data is presented in the article about the role of 13C-mixed triglyceride and 13C-corn starch breath tests as a tools for exocrine pancreatic insufficiency diagnosis, for evaluating fat and starch malabsorbtion in CP patients. 135 patients were included in the investigation. It has been shown, that 13C-breath tests could be useful tools in clinical practice for CP diagnosis. They are well correlate with fecal elastase-1 level, has high sensitivity and specificity for diagnosis of lipase and amylase deficiency. Tests make it possible to choose the initial pancreatic enzyme dosage and are beneficial during the treatment for pancreatic enzyme dose correction.

  7. Panic disorder in a breath-holding challenge test: a simple tool for a better diagnosis

    Directory of Open Access Journals (Sweden)

    Nardi Antonio E.

    2003-01-01

    Full Text Available OBJECTIVE: Our aim was to observe if anxiety disorder patients - DSM-IV - respond in a similar way to the induction of panic attacks by a breath-holding challenge test. METHOD: We randomly selected 29 panic disorder (PD patients, 27 social anxiety disorder (SAD patients, 21 generalized anxiety disorder (GAD patients. They were induced to breath-hold for as long as possible four times with two-minute interval between them. Anxiety scales were applied before and after the test. RESULTS: A total of 44.8% (n=13 PD patients, 14.8% (n=4 SAD patients, 9.5% (n=2 GAD patients had a panic attack after the test (c²= 21.44, df= 2, p=0.001. There was no heart rate or anxiety levels difference among the groups before and after the test. CONCLUSION: In this breath-holding challenge test the panic disorder patients were more sensitive than other anxiety disorder patients.

  8. Update on diagnostic value of breath test in gastrointestinal and liver diseases

    Institute of Scientific and Technical Information of China (English)

    Imran Siddiqui; Sibtain Ahmed; Shahab Abid

    2016-01-01

    In the field of gastroenterology,breath tests(BTs) are used intermittently as diagnostic tools that allow indirect,non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered.The aim of this review is to have an insight into the principles,methods of analysis and performance parameters of various hydrogen,methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection,small intestinal bacterial overgrowth,and carbohydrate malabsorption.Evaluation of gastric emptying is routinely performed by scintigraphy which is however,difficult to perform and not suitable for children and pregnant women,this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges.A new development such as electronic nose test is also highlighted.Moreover we have also explored the limitations and constraints restraining the wide use of these BT.We conclude that breath testing has an enormous potential to be used as a diagnostic modality.In addition it offers distinct advantages over the traditional invasive methods commonly employed.

  9. 13CO2 breath test to measure the hydrolysis of various starch formulations in healthy subjects.

    OpenAIRE

    Hiele, M; Ghoos, Y; Rutgeerts, P; Vantrappen, G; de Buyser, K

    1990-01-01

    13CO2 starch breath test was used to study the effect of physicochemical characteristics of starch digestion. As starch is hydrolysed to glucose, which is subsequently oxidised to CO2, differences in 13CO2 excretion after ingestion of different starch products must be caused by differences in hydrolysis rate. To study the effect of the degree of chain branching, waxy starch, containing 98% amylopectin, was compared with high amylose starch, containing 30% amylopectin, and normal crystalline s...

  10. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    Directory of Open Access Journals (Sweden)

    Yong-Jian Ma

    2016-01-01

    Full Text Available This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0±5.9 d rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0±4.0 d, and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0±2.9 d were statistically similar (all p>0.05 to and linearly correlated (r=0.96, p<0.01 with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0±2.7 d; RIB10, 33.0±1.3 d; and RIB20, 27.0±0.8 d. The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models.

  11. Evaluation of small intestine bacterial overgrowth in patients with functional dyspepsia through H2 breath test

    Directory of Open Access Journals (Sweden)

    Michelle Bafutto Gomes Costa

    2012-12-01

    Full Text Available CONTEXT: Functional dyspepsia is a condition in which symptoms are not related to organic underlying disease; its pathogenesis is not well known. The small intestinal bacterial overgrowth (SIBO is characterized by the increase in the number and/or type of colonic bacteria in the upper gastrointestinal tract. The hypothesis of SIBO being associated to functional dyspepsia must be considered, since the impaired motility of the gastrointestinal tract is one of the main etiologic factors involved on both pathologies. OBJECTIVE: To determine if there is SIBO in patients with functional dyspepsia. METHODS: Case-control study, evaluating 34 patients: 23 functional dyspeptic and 11 non-dyspeptic (control group. Questionnaire applied based on Rome III criteria. The patients underwent H2-lactulose breath test, considered positive when: H2 peak exceeding 20 ppm, in relation to fasting, or two peaks exceeding 10 ppm sustained until 60 minutes. RESULTS: Of the 23 dyspeptic patients, 13 (56.5% obtained positive results for SIBO trough the H2-lactulose breath test. On control group, SIBO was not observed. The association between the dyspeptic group and the control group regarding SIBO was statistically significant, with P = 0.0052. In the group of dyspeptic patients, 12 (52.2% were using proton pump inhibitor; of these 9 (75% were positive for SIBO. In the control group, none of the 11 patients used proton pump inhibitors and SIBO was not observed. The association of the dyspeptic group using proton pump inhibitor that were positive for SIBO and the control group was statistically significant, with P = 0.0011. CONCLUSION: It was found that, patients with functional dyspepsia presented SIBO, when they underwent to H2-lactulose breath test, compared to the non-dyspeptic. In addition, it was observed a higher prevalence of SIBO in dyspeptic patients that were using proton pump inhibitors, compared to control group.

  12. Valutazione comparativa di un test immunocromatografico “Helicobacter pylori Antigen Onestep Test” e di due test immunoenzimatici “Fecal-clean H. pylori Ag” e “Amplified IDEIATM Hp StARTM” per la diagnosi di infezione da Helicobacter pylori attraverso ric

    Directory of Open Access Journals (Sweden)

    Antonella Marangoni

    2004-03-01

    Full Text Available Helicobacter pylori causes gastritis and peptic ulcer disease and has been associated with gastric malignancies. During recent years, non invasive diagnostic tests have gained in significance.Well-established non invasive tests are serology and the [13C] urea breath test. Serology, however, is not suitable for an early follow-up examination due to the slow reduction of the anti-H. pylori antibody titer after successful treatment. The [13C] urea breath test-delivering accurate results both in the pretreatment examination of infected individuals and in the early post treatment control-fulfills the demands for such a test. However, expensive instrumentation and a specialized technician are required. Since infected individuals excrete H. pylori in stool specimens, a sufficiently accurate test using feces would be an important alternative to [13C] urea breath test. In this study we compared the diagnostic performances of the immunocromatographic test “Helicobacter pylori Antigen Onestep Test” with those of two enzyme linked immunoassay tecniques “Fecal-clean H. pylori Ag” and “Amplified IDEIATM Hp StARTM” for detection of H. pylori antigens in stool specimens.The values of agreement ranged from 89.6% to 93.6%.

  13. Interpretation of non-invasive breath tests using 13C-labeled substrates - a preliminary report with 13C-methacetin

    Directory of Open Access Journals (Sweden)

    Lock JF

    2009-12-01

    Full Text Available Abstract Non-invasive breath tests can serve as valuable diagnostic tools in medicine as they can determine particular enzymatic and metabolic functions in vivo. However, methodological pitfalls have limited the actual clinical application of those tests till today. A major challenge of non-invasive breath tests has remained the provision of individually reliable test results. To overcome these limitations, a better understanding of breath kinetics during non-invasive breaths tests is essential. This analysis compares the breath recovery of a 13C-methacetin breath test with the actual serum kinetics of the substrate. It is shown, that breath and serum kinetics of the same test are significantly different over a period of 60 minutes. The recovery of the tracer 13CO2 in breath seems to be significantly delayed due to intermediate storage in the bicarbonate pool. This has to be taken into account for the application of non-invasive breath test protocols. Otherwise, breath tests might display bicarbonate kinetics despite the metabolic capacity of the particular target enzyme.

  14. New Zealand's breath and blood alcohol testing programs: further data analysis and forensic implications.

    Science.gov (United States)

    Stowell, A R; Gainsford, A R; Gullberg, R G

    2008-07-01

    Paired blood and breath alcohol concentrations (BAC, in g/dL, and BrAC, in g/210 L), were determined for 11,837 drivers apprehended by the New Zealand Police. For each driver, duplicate BAC measurements were made using headspace gas chromatography and duplicate BrAC measurements were made with either Intoxilyzer 5000, Seres 679T or Seres 679ENZ Ethylometre infrared analysers. The variability of differences between duplicate results is described in detail, as well as the variability of differences between the paired BrAC and BAC results. The mean delay between breath and blood sampling was 0.73 h, ranging from 0.17 to 3.1 8h. BAC values at the time of breath testing were estimated by adjusting BAC results using an assumed blood alcohol clearance rate. The paired BrAC and time-adjusted BAC results were analysed with the aim of estimating the proportion of false-positive BrAC results, using the time-adjusted BAC results as references. When BAC results were not time-adjusted, the false-positive rate (BrAC>BAC) was 31.3% but after time-adjustment using 0.019 g/dL/h as the blood alcohol clearance rate, the false-positive rate was only 2.8%. However, harmful false-positives (defined as cases where BrAC>0.1 g/210L, while BACtest results were used as the evidential results instead of the means, the harmful false-positive rate dropped to 0.04%.

  15. Food restriction normalizes chylomicron remnant metabolism in murine models of obesity as assessed by a novel stable isotope breath test.

    Science.gov (United States)

    Martins, Ian J; Tran, J M L; Redgrave, Trevor G

    2002-02-01

    Evidence is increasing that defective metabolism of postprandial remnants of triglyceride-rich lipoproteins contributes to atherogenesis. In obesity, postprandial lipemia is increased by mechanisms that are not currently established. In the present study, a recently developed (13)CO(2) breath test was used to assess the metabolism of chylomicron remnants (CR) in obese mice. Six murine obese models ob/ob, fat/fat, New Zealand Obese (NZO), db/db, gold thioglucose (GTG)-treated and agouti (A(y)) were studied. All obese mice were hyperphagic and their breath test metabolism was markedly impaired (P obese models such as db/db were diabetic, our data suggest that the defective breath test was independent of diabetes because all obese and diabetic models responded similarly to food restriction. Impaired hepatic catabolism of CR was excluded as a cause of the abnormal breath tests. In summary, the impairment (P < 0.05) in remnant metabolism as assessed by the breath test in obese mice was corrected by food restriction, associated with improvements in plasma glucose, triglyceride and cholesterol levels.

  16. Carbon-14 urea breath test for the diagnosis of Campylobacter pylori associated gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, B.J.; Surveyor, I.

    1988-01-01

    Urease in the human gastric mucosa is a marker for infection with Campylobacter pylori (CP), an organism suspected of causing chronic gastritis and peptic ulceration. To detect gastric urease, we examined 32 patients who were being evaluated for possible peptic ulcer disease. Fasting patients were given 10 microCi (370 kBq) of /sup 14/C-labeled urea. Breath samples were collected in hyamine at intervals between 1 and 30 min. The amount of /sup 14/C collected at these times was expressed as: body weight X (% of administered dose of /sup 14/C in sample)/(mmol of CO/sub 2/ collected). The presence of C. pylori colonization was also determined by examination of multiple endoscopic gastric biopsy specimens. On average, patients who were proven to have C. pylori infection exhaled 20 times more labeled CO/sub 2/ than patients who were not infected. The difference between infected patients and C. pylori negative control patients was highly significant at all time points between 2 and 30 min after ingestion of the radionuclide (p less than 0.0001). The noninvasive urea breath is less expensive than endoscopic biopsy of the stomach and more accurate than serology as a means of detecting Campylobacter pylori infection. Because the test detects actual viable CP organisms, it can be used to confirm eradication of the bacterium after antibacterial therapy.

  17. Early postoperative erythromycin breath test correlates with hepatic cytochrome P4503A activity in liver transplant recipients

    DEFF Research Database (Denmark)

    Schmidt, L E; Olsen, A K; Stentoft, K;

    2001-01-01

    milligram of protein, and the activity determined by testosterone 6beta-hydroxylation ranged from 0.030 to 0.627 nmol per minute per milligram of protein. Significant correlation was demonstrated between the erythromycin breath test and both the erythromycin demethylation (Spearman correlation coefficient......: R = 0.76, R (2) = 0.57; P =.0004) and the testosterone 6beta-hydroxylation (Spearman correlation coefficient: R = 0.79, R (2) = 0.63; P =.0001) assays. The erythromycin breath test also correlated with the CYP3A protein level (Spearman correlation coefficient: R = 0.60, R (2) = 0.36; P =.01...

  18. Comparison of breath-alcohol screening test results with venous blood alcohol concentration in suspected drunken drivers.

    Science.gov (United States)

    Kriikku, Pirkko; Wilhelm, Lars; Jenckel, Stefan; Rintatalo, Janne; Hurme, Jukka; Kramer, Jan; Jones, A Wayne; Ojanperä, Ilkka

    2014-06-01

    Hand-held electronic breath-alcohol analyzers are widely used by police authorities in their efforts to detect drunken drivers and to improve road-traffic safety. Over a three month period, the results of roadside breath-alcohol tests of drivers apprehended in Finland were compared with venous blood alcohol concentration (BAC). The mean (median) time between sampling blood and breath was 0.71h (0.58h) with a range from 0 to 6h. Some hand-held instruments gave results as the concentration of alcohol in breath and were converted into BAC assuming a blood-breath alcohol ratio (BBR) of 2260. The mean venous BAC (1.82g/kg) in traffic offenders was higher than the result predicted by the hand-held breath analyzers (1.72g/kg). In 1875 roadside tests, the relationship between venous BAC (x) and BrAC (y) was defined by the regression equation y=0.18+0.85x. The coefficients show both a constant bias (y-intercept 0.18g/kg) and a proportional bias (slope=0.85). The residual standard deviation (SD), an indicator of random variation, was ±0.40g/kg. After BAC results were corrected for the time elapsed between sampling blood and breath, the y-intercept decreased to 0.10g/kg and 0.004g/kg, respectively, when low (0.1g/kg/h) and high (0.25g/kg/h) rates of alcohol elimination were used. The proportional bias of 0.85 shows that the breath-alcohol test result reads lower than the actual BAC by 15% on average. This suggests that the BBR of 2260 used for calibration should be increased by about 15% to give closer agreement between BAC and BrAC. Because of the large random variation (SD±0.40g/kg), there is considerable uncertainty if and when results from the roadside screening test are used to estimate venous BAC. The roadside breath-alcohol screening instruments worked well for the purpose of selecting drivers above the statutory limit of 0.50g/kg.

  19. Relationship between postoperative erythromycin breath test and early morbidity in liver transplant recipients

    DEFF Research Database (Denmark)

    Schmidt, Lars E; Rasmussen, Allan; Kirkegaard, Preben;

    2003-01-01

    BACKGROUND: Interindividual variability in dosage requirements of the calcineurin inhibitor immunosuppressive agents cyclosporine and tacrolimus after liver transplantation may result from differences in the CYP3A activity of the liver graft. Early postoperative erythromycin breath test (ERMBT......) is an in vivo measure of graft CYP3A activity. This study evaluates the usefulness of an early postoperative ERMBT in predicting early morbidity in liver transplant recipients. METHODS: In 26 liver transplant recipients, ERMBT was performed within 2 hr after transplantation. Main end points were the occurrence...... with low postoperative ERMBT values (0.21%+/-0.15% 14C/hr vs. 1.09%+/-0.72% 14C/hr, P=0.002). CONCLUSION: An early postoperative ERMBT may be useful in predicting the development of cyclosporine and tacrolimus nephrotoxicity, severe graft dysfunction, or even graft loss in liver transplant recipients when...

  20. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Science.gov (United States)

    2010-10-01

    ... test using a saliva ASD or a breath tube ASD? 40.245 Section 40.245 Transportation Office of the... Alcohol Screening Tests § 40.245 What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the...

  1. Mathematical analysis of [13CO2]-expiration curves from human breath tests using [1-13C]-amino acids as oral substrate

    NARCIS (Netherlands)

    Schreurs, V.V.A.M.; Krawielitzki, K.

    2003-01-01

    A [13CO2]-breath test examines the expiration of [13CO2] as function of time after oral intake of a [13C]-labelled test substrate (single dose). In clinical settings, breath test studies are often used as a simple and non-invasive tool to diagnose the activity of metabolic functions. From a nutritio

  2. [Cardiopulmonary exercise testing in chronic obstructive pulmonary disease (COPD) - breath-functional characterization and disease severity assessment].

    Science.gov (United States)

    Mühle, A; Obst, A; Winkler, J; Ewert, R

    2015-09-01

    COPD is a heterogeneous disease with a wide range of clinical phenotypes and breath-functional dysfunctions. Cardiopulmonary exercise testing (CPET) allows describing all component parts of breathing and determining exercise capacity and the mechanisms of exercise limitation. From these aspects 64 COPD patient stages II, III and IV according to the conventional GOLD classification were examined by means of CPET to evaluate whether CPET can provide a better functional characterization of COPD than the standard investigation procedures in pulmonary practice.We could show that in pulmonary practice CPET is safely and effectively practicable in stable COPD patients of all GOLD stages. This method allowed a clinical and prognostic disease severity assessment of all patients, proving important differences of peak oxygen uptake in each GOLD stage, so that patients in spite of identical GOLD disease severity were to be assigned to different prognostic groups according CPET criteria. Furthermore, we found relevant differences of individual breath-functional patterns in exercise, which can neither be objectified nor be prognosticated by standard investigation procedures at rest.Therefore CPET allows, aside from an objective clinical and prognostic disease severity assessment, also a breath-functional evaluation in a subtly way in COPD patients reflecting the multidimensional background of the disease with variable dysfunctions in pulmonary ventilation, gas exchange, circulation and muscular function as well as associated cardio vascular comorbidities. The breath-functional phenotyping of the COPD patient seems to be meaningful in particular for an individualised therapy management.

  3. Employing components-of-variance to evaluate forensic breath test instruments.

    Science.gov (United States)

    Gullberg, Rod G

    2008-03-01

    The evaluation of breath alcohol instruments for forensic suitability generally includes the assessment of accuracy, precision, linearity, blood/breath comparisons, etc. Although relevant and important, these methods fail to evaluate other important analytical and biological components related to measurement variability. An experimental design comparing different instruments measuring replicate breath samples from several subjects is presented here. Three volunteers provided n = 10 breath samples into each of six different instruments within an 18 minute time period. Two-way analysis of variance was employed which quantified the between-instrument effect and the subject/instrument interaction. Variance contributions were also determined for the analytical and biological components. Significant between-instrument and subject/instrument interaction were observed. The biological component of total variance ranged from 56% to 98% among all subject instrument combinations. Such a design can help quantify the influence of and optimize breath sampling parameters that will reduce total measurement variability and enhance overall forensic confidence.

  4. Non-invasive detection of low-intestinal lactase activity in children by use of a combined (CO2)-C-13/H-2 breath test

    NARCIS (Netherlands)

    Koetse, HA; Stellaard, F; Bijleveld, CMA; Elzinga, H; Boverhof, R; van der Meer, R; Vonk, RJ; Sauer, PJJ

    1999-01-01

    Background: The aim of the study was to diagnose hypolactasia with a higher accuracy than with the traditional H-2 breath test. Methods: We used a combined C-13-lactose (CO2)-C-13/H-2 breath test, which was performed in 33 patients in whom lactase activity was measured. Results: Lactase activity was

  5. Solubility testing of actinides on breathing-zone and area air samples

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L. [Radiation Safety Engineering, Inc., Chandler, AZ (United States)

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS{reg_sign}) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U{sub 3}O{sub 8}. Profiles developed for U{sub 3}O{sub 8} samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills.

  6. Additional Value of CH4 Measurement in a Combined 13C/H2 Lactose Malabsorption Breath Test: A Retrospective Analysis

    Directory of Open Access Journals (Sweden)

    Els Houben

    2015-09-01

    Full Text Available The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2 excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO, and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO.

  7. The influence of breathing type, expiration and cervical posture on the performance of the cranio-cervical flexion test in healthy subjects.

    Science.gov (United States)

    Cagnie, Barbara; Danneels, Lieven; Cools, Ann; Dickx, Nele; Cambier, Dirk

    2008-06-01

    The cranio-cervical flexion test (CCF-T) is used as a clinical evaluation tool for the deep cervical flexors (DCF). The influence of breathing type, expiration and cervical posture on the performance of the test is evaluated in asymptomatic subjects. Thirty volunteers participated in the study and were classified according to their breathing type: costo-diaphragmatic breathing type and upper costal breathing type. Sternocleidomastoid (SCM) electromyographic (EMG) activity was recorded during five incremental levels of CCF during normal breathing as well as during expiration. The cranio-vertebral angle of each subject was measured to quantify cervical posture. During normal inspiration, higher EMG activity of the SCM muscles was observed in subjects with an upper costal breathing pattern compared to costo-diaphragmatic breathing subjects. This difference was statistically significant (Pangle and the EMG activity of the SCM muscles. Performing the CCF-T during slow expiration diminishes the activity of the SCM muscles in subjects with a predominantly upper costal breathing pattern. Using a costo-diaphragmatic breathing pattern while performing the test will optimize the performance. Studies on neck pain patients are required to further clarify this issue.

  8. Validation of ten-minute single sample carbon-14 urea breath test for diagnosis of Helicobacter pylori infection

    Energy Technology Data Exchange (ETDEWEB)

    Prabakaran, K.; Fernandes, V.; McDonald, J. [Illawarra Regional Hospital, Wollongong, NSW (Australia). Depts of Nuclear Medicine and Gastroenterology

    1996-09-01

    Helicobacter pylori infection is traditionally diagnosed by endoscopy followed by gastric biopsy and histologic demonstration of organisms, rapid urease test and culture. The non-invasive carbon-14-urea breath test has been widely accepted now for the diagnosis of this bacterium. This study was aimed to establish and validate normal and abnormal values for an Australian population, for a single sample carbon-14-urea breath test at ten minutes. A dose of 185 kBq was used in order to achieve reasonable counting statistics. The derived values were validated with the results of the rapid urease test. This method has a high sensitivity, specificity and greater patient acceptance, and could be used in many clinical settings as the first modality for the diagnosis of H. pylori infection and for documenting response or cure after antibiotic therapy for eradication. 11 refs., 1 tab., 4 figs.

  9. Gastric emptying rate in subjects with malocclusion examined by [(13) C] breath test.

    Science.gov (United States)

    Koike, S; Sujino, T; Ohmori, H; Shimazaki, K; Fukuyama, E; Kanai, T; Hibi, T; Ono, T

    2013-08-01

    Masticatory function is significantly lower in individuals with malocclusion than in those with normal occlusion. Although several studies suggest that masticatory function influences gastrointestinal digestive function, the relationship between malocclusion and gastrointestinal symptoms has not been studied extensively. We hypothesised that insufficient masticatory function would increase the functional burden of the stomach and have some influence on the gastrointestinal system. The purpose of this study was to investigate masticatory function and gastric emptying rate in subjects with malocclusion. Eleven healthy dentate female volunteers and eleven female patients with maloc-clusion underwent a (13) C-acetate breath test with a liquid meal. Maximum (13) CO2 exhalation time (Tmax ) was compared statistically between both groups. Masticatory function was assessed by colour-changeable chewing gum. In addition, the frequency scale for the symptoms of gastroeso-phageal reflux disease (FSSG) and questionnaires on food intake were given to both groups. The mean Tmax of the malocclusion group was significantly longer than that of the normal occlusion group (P = 0·007). Masticatory performance, measured by colour-changeable gum and questionnaires, was significantly lower in the malocclusion group than in the normal occlusion group (P = 0·023, P = 0·003). There was no significant difference in the FSSG results between the two groups (P = 0·262). This study suggested that there was a correlation between malocclusion and gastric emptying function in women.

  10. Assessment of antibacterial effect of garlic in patients infected with Helicobacter pylori using urease breath test

    Science.gov (United States)

    Zardast, Mahmoud; Namakin, Kokab; Esmaelian Kaho, Jamil; Hashemi, Sarira Sadat

    2016-01-01

    Objective: Helicobacter pylori (H. pylori) is the most common pathogenic bacteria in the stomach. The aim of the current study was to explore the effect of oral garlic administration on bacterial urease activity inside the stomach and its contribution to the treatment of H. pylori infection. Materials and Methods: In this clinical trial, 15 patients were studied quantitatively with Urease Breath Test (UBT). The patients with gastrointestinal symptoms and a positive serum H. pylori IgG were enrolled. UBT was performed for each patient in three sessions as follows: at the beginning of the study, an initial UBT was performed based on which, the positive cases entered the study and the negative ones were excluded. Second UBT was done three days later in patients who were not receiving any treatment and were considered as the control, whereas the third UBT was performed three days after prescribing two medium-sized cloves of garlic (3 g) with their meal, twice a day (at noon and in the evening). The collected data were analyzed using ANOVA and Bonferroni tests and the significance level was set at p<0.05. Results: the mean UBT significantly differed before and after treatment with garlic cloves, being significantly lower after garlic consumption. No meaningful difference was observed in the mean UBT without garlic consumption between the first and second steps. Conclusion: Raw garlic has anti-bacterial effects against H. pylori residing in the stomach and may be prescribed along with routine drugs for the treatment of gastric H. pylori infection. PMID:27761418

  11. Breath test measurements in combination with indirect calorimetry for estimation of 13C-leucine oxidation in mink (Mustela vison)

    DEFF Research Database (Denmark)

    Tauson, Anne-Helene; Ali, Abdalla; Kanska, Katarzyna

    2000-01-01

    Gas exchange measurements by means of indirect calorimetry can be used to calculate quantitative substrate oxidation. The results represents average net oxidation values (substrate disappearance rate), but they cannot describe the dynamics of the oxidation processes. Breath test measurements...... to feeding and fasting. Twelve 1-year-old male mink (Mustela vison) were measured in each five consecutive periods by means of indirect calorimetry and simultaneous breath test. In Periods 1, 3 and 5, each lasting 3 days, the animals were fed ad libitum and Periods 2 and 4 were fasting periods, each of 48 h....... In Periods 1 and 5 all animals were fed a diet with a high quality fish meal (FISH; n=12), while in Period 3 half of the animals received the FISH diet (n=6) and the other half a diet with soy protein concentrate (SOY; n=6) as main protein source. An intraperitoneal injection of 1-13C-leucine was given...

  12. Evaluation of a simple non-invasive 13C breath test to evaluate diet effects on gastric emptying in pigs

    DEFF Research Database (Denmark)

    Jørgensen, Henry; Strathe, Anders Bjerring; Theil, Peter Kappel

    2010-01-01

    to feeding (15.5 h after the previous meal) on the day when the 5 h sample was taken. In the breath test four pregnant sows were placed in respiration chambers and the 13C marker was added in the morning meal and air samples were collected up to 18 h at the outlet from the chambers and detected on an infra...

  13. Effects of tetrahydrobiopterin and phenylalanine on in vivo human phenylalanine hydroxylase by phenylalanine breath test.

    Science.gov (United States)

    Okano, Yoshiyuki; Takatori, Kazuhiko; Kudo, Satoshi; Sakaguchi, Tomoko; Asada, Minoru; Kajiwara, Masahiro; Yamano, Tsunekazu

    2007-12-01

    BH(4) administration results in the reduction of blood phenylalanine level in patients with tetrahydrobiopterin (BH(4))-responsive phenylalanine hydroxylase (PAH) deficiency. The mechanism underlying BH(4) response remains unknown. Here, we studied the effects of BH(4) and phenylalanine on in vivo PAH activity of normal controls using the phenylalanine breath test (PBT) by converting l-[1-(13)C] phenylalanine to (13)CO(2). Phenylalanine oxidation rates were expressed as Delta(13)C ((13)CO(2)/(12+13)CO(2), per thousand) and cumulative recovery rates over 120min (CRR(120), %; total amount of (13)CO(2)/the administered dose of (13)C-phenylalanine). Under physiological conditions of blood phenylalanine, BH(4) administration reduced the Delta(13)C peak from 40.8 per thousand to 21.6 per thousand and CRR(120) from 16.9% to 10.2%. Under high blood phenylalanine conditions, administration of BH(4) increased the Delta(13)C peak from 30.7 per thousand to 46.0 per thousand, while the CRR(120) was similar between phenylalanine (19.9%) and phenylalanine+BH(4) (21.1%) groups. Corrected Delta(13)C and CRR(120) were calculated against serum phenylalanine levels to remove the effects of phenylalanine loading. After BH(4) administration, the corrected Delta(13)C peak increased from 82.7 per thousand to 112.6 per thousand, while the corrected CRR(120) was similar (47.6% and 45.6%). These results indicate that phenylalanine worked as a regulator of in vivo PAH by serving as both a substrate and an activator for the enzyme. Excessive dosages of BH(4) inhibited PAH under normal phenylalanine conditions and activated PAH under conditions of high phenylalanine. The regulation system is therefore designed to maintain phenylalanine levels in the human body. Appropriate BH(4) supplementation must be reviewed in patients with BH(4)-responsive PAH deficiency.

  14. Use of naturally enriched mixed food in 13C breath tests applied in young suckling calves.

    Science.gov (United States)

    Metges, C C; Schmidt, H L; Eichinger, H

    1992-01-01

    Utilization of three milk diets including cream, casein or whey, each naturally labelled with 13C (1 mmol 13C excess) from C4 sources, by six young male calves of the Deutsche Fleckvieh breed was investigated in a Latin-square split-plot design. Each milk diet was examined under resting conditions and during a short period of physical exercise on a treadmill. Delta 13C values (/1000) in carbon dioxide in expired air were measured at intervals of about 1 h during 6.5 h after food intake. Expired air samples for CO2 isolation, subsequent isotopic analysis, measurement of CO2 production and respiratory quotient were taken at about hourly intervals and 13C recovery rates over 6.5 h were calculated. Feeding milk containing enriched milk casein, cream, or whey resulted in maximal significant 13C enrichments over background (delta 13C) in CO2 of +1, +2.4 and +2.2 /1000, and recovery rates of 3.6, 9.9 and 12.2% respectively. This comparison shows the different kinetic behaviour of the main nutrients during the oxidation in tissues. The short exercise period (5 min at 1 J/s per kg body-weight +5 min at 2 J/s per kg body-weight) did not influence the recovery rates significantly. However, after 10 min of muscular exercise there was a brief decrease in delta 13C value of expired air which disappeared within the first 5 min of rest. These experiments demonstrate for the first time the applicability of the 13C breath test with naturally enriched diets in animal nutrition research and that quantitative results may be obtained.

  15. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    Science.gov (United States)

    Khng, Kiat Hui

    2016-09-26

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  16. Breathing Problems

    Science.gov (United States)

    ... getting enough air. Sometimes you can have mild breathing problems because of a stuffy nose or intense ... panic attacks Allergies If you often have trouble breathing, it is important to find out the cause.

  17. Metallo-Dielectric Multilayer Structure for Lactose Malabsorption Diagnosis through H2 Breath Test

    CERN Document Server

    Cioffi, N; De Sario, M; D'Orazio, A; Petruzzelli, V; Prudenzano, F; Scalora, M; Trevisi, S; Vincenti, M A

    2007-01-01

    A metallo-dielectric multilayer structure is proposed as a novel approach to the analysis of lactose malabsorption. When lactose intolerance occurs, the bacterial overgrowth in the intestine causes an increased spontaneous emission of H2 in the human breath. By monitoring the changes in the optical properties of a multilayer palladium-polymeric structure, one is able to detect the patient's disease and the level of lactose malabsorption with high sensitivity and rapid response.

  18. Fourier-transformed infrared breath testing after ingestion of technical alcohol.

    Science.gov (United States)

    Laakso, Olli; Haapala, Matti; Pennanen, Teemu; Kuitunen, Tapio; Himberg, Jaakko-Juhani

    2007-07-01

    The study aim was to evaluate the feasibility of a Fourier-transformed infrared (FT-IR) analyzer for out-of-laboratory use by screening the exhalations of inebriated individuals, and to determine analysis quality using common breath components and solvents. Each of the 35 inebriated participants gave an acceptable sample. Because of the metabolism of 2-propanol, the subjects exhaled high concentrations of acetone in addition to ethanol. Other volatile ingredients of technical ethanol products (methyl ethyl ketone, methyl isobutyl ketone, and 2-propanol) were also detected. The lower limits of quantification for the analyzed components ranged from 1.7 to 12 microg/L in simulated breath samples. The bias was +/-2% for ethanol and -11% for methanol. Within-day and between-day coefficients of variation were <1% for ethanol and <4% for methanol. The bias of ethanol and methanol analyses due to coexisting solvents ranged from -0.8 to +2.2% and from -5.6 to +2.9%, respectively. The FT-IR method proved suitable for use outside the laboratory and fulfilled the quality criteria for analysis of solvents in breath.

  19. Radiation exposure of the patient in diagnostic nuclear medicine. Experimental studies of the biokinetics of {sup 111}In-DTPA-D-Phe{sup 1}-octreotide, {sup 99m}Tc-MIBI, {sup 14}C-triolein and {sup 14}C-urea, and development of dosimetric models

    Energy Technology Data Exchange (ETDEWEB)

    Leide Svegborn, S

    1999-03-01

    Biokinetic and dosimetric models for a number of clinically used radiopharmaceuticals, for which information on the radiation dosimetry is scarce, have been produced. On patients undergoing investigations with {sup 111}In-DTPA-D-Phe{sup 1}-octreotide (for diagnosis of neuroendocrine tumours) and {sup 99m}Tc-MIBI (for myocardial perfusion imaging), whole body gamma camera scanning was performed several times after administration of the radiopharmaceutical. Total body and organ activity content was determined using the geometric mean of the number of counts in two 180 deg opposed planar images. A thorough investigation of sources influencing the accuracy of the quantification of activity was carried out, showing an overall uncertainty varying from 10% to 30% for organs with a significant uptake and 5% for the whole body. The activity in blood and urine was also measured. {sup 111}In-DTPA-D-Phe{sup 1}-octreotide was predominantly excreted via the kidney-bladder system and a typical investigation with 1200 MBq resulted in an effective dose of 8.4 mSv (0.076 mSv/MBq). {sup 99m}Tc-MIBI was to a great extent excreted via the gastrointestinal tract and an investigation with 1200 MBq resulted in an effective dose of 13 mSv (0.011 mSv/MBq). Accelerator mass spectrometry (AMS) was used to investigate the possibility to measure ultra-low activity concentrations of {sup 14}CO{sub 2}, in exhaled air from patients undergoing {sup 14}C-breath tests, with special application to {sup 14}C-triolein (for study of fat malabsorption). AMS was proven to be a useful technique for long-term retention studies of {sup 14}C, and was used together with liquid scintillation counting in an investigation of the biokinetics of {sup 14}C-urea in adult and paediatric patients (for diagnosis of Helicobacter pylori infection in the upper gastrointestinal tract). The effective dose for {sup 14}C-urea was 0.019 mSv/MBq for adults and from 0.041 to 0.019 mSv/MBq for seven- to fourteen -year-old children

  20. Measurement of liver function for patients with cirrhosis by 13C-methacetin breath test compared with Child-Pugh score and routine liver function tests

    Institute of Scientific and Technical Information of China (English)

    LIU Yun-xiang; HUANG Liu-ye; WU Cheng-rong; CUI Jun

    2006-01-01

    @@ 13C-methacetin breath test was used for the evaluation of liver function, as for quantitative data could be achieved using this method, it had the characteristics of safety,quantification, and repetition and got recognition gradually through the world.1,2 We began this 13C-methacetin test to assess liver function of patients with cirrhosis from January 2002. The aim of this study was to explore the characteristic of this test for liver function evaluation and explore the correlation of this method with some clinical liver biochemical parameters and Child-Pugh score.

  1. Lactose Malabsorption Testing in Daily Clinical Practice: A Critical Retrospective Analysis and Comparison of the Hydrogen/Methane Breath Test and Genetic Test (C/T-13910 Polymorphism Results

    Directory of Open Access Journals (Sweden)

    Dietmar Enko

    2014-01-01

    Full Text Available The aim of this study was to establish a retrospective evaluation and comparison of the hydrogen/methane (H2/CH4 breath test and genetic test (C/T−13910 polymorphism results in lactose malabsorption testing. In total 263 consecutive patients with suspected lactose malabsorption were included in this study. They underwent the H2/CH4 breath test following the ingestion of 50 g lactose and were tested for the C/T−13910 polymorphism. In total 51 patients (19.4% had a C/C−13910 genotype, indicating primary lactose malabsorption. Only 19 patients (7.2% also had a positive H2/CH4 breath test. All in all 136 patients (51.69% had a C/T−13910 and 76 patients (28.91% a T/T−13910 genotype, indicating lactase persistence. Four patients (1.5% with the C/T−13910 genotype and one patient (0.4% with the T/T−13910 genotype had a positive H2/CH4 breath test result, indicating secondary lactose malabsorption. Cohen's Kappa measuring agreement between the two methods was 0.44. Twenty patients (7.6% with a positive H2/CH4 peak within 60 minutes after lactose ingestion were classified as patients with lactose-dependent small intestinal bacterial overgrowth (SIBO. In conclusion, only moderate agreement between the breath test and the genetic test was shown. Secondary lactose malabsorption as well as preanalytical limitations of the combined H2/CH4 breath test procedure can cause discrepant results. This trial is registered with K-42-13.

  2. Molecular hydrogen in human breath: a new strategy for selectively diagnosing peptic ulcer disease, non-ulcerous dyspepsia and Helicobacter pylori infection.

    Science.gov (United States)

    Maity, Abhijit; Pal, Mithun; Maithani, Sanchi; Ghosh, Barnali; Chaudhuri, Sujit; Pradhan, Manik

    2016-07-22

    The gastric pathogen Helicobacter pylori utilizes molecular hydrogen (H2) as a respiratory substrate during colonization in the gastric mucosa. However, the link between molecular H2 and the pathogenesis of peptic-ulcer disease (PUD) and non-ulcerous dyspepsia (NUD) by the enzymatic activity of H. pylori still remains mostly unknown. Here we provide evidence that breath H2 excretion profiles are distinctly altered by the enzymatic activity of H. pylori for individuals with NUD and PUD. We subsequently unravelled the potential molecular mechanisms responsible for the alteration of H2 in exhaled breath in association with peptic ulcers, encompassing both gastric and duodenal ulcers, along with NUD. We also established that carbon-isotopic fractionations in the acid-mediated bacterial environment regulated by bacterial urease activity cannot discriminate the actual disease state i.e. whether it is peptic ulcer or NUD. However, our findings illuminate the unusual molecular H2 in breath that can track the precise evolution of PUD and NUD, even after the eradication of H. pylori infection. This deepens our understanding of the pathophysiology of PUD and NUD, reveals non-invasively the actual disease state in real-time and thus offers a novel and robust new-generation strategy for treating peptic-ulcer disease together with non-ulcer related complications even when the existing (13)C-urea breath test ((13)C-UBT) fails to diagnose.

  3. Fabry-Perot microcavity sensor for H2-breath-test analysis

    Science.gov (United States)

    Vincenti, Maria Antonietta; De Sario, Marco; Petruzzelli, V.; D'Orazio, Antonella; Prudenzano, Francesco; de Ceglia, Domenico; Scalora, Michael

    2007-10-01

    Leak detection of hydrogen for medical purposes, based on the monitoring of the optical response of a simple Fabry-Perot microcavity, is proposed to investigate either the occurrence of lactose intolerance, or lactose malabsorption condition. Both pathologic conditions result in bacterial overgrowth in the intestine, which causes increased spontaneous emission of H2 in the human breath. Two sensitivity figures of merit are introduced to inspect changes in the sensor response, and to relate the microcavity response to a pathologic condition, which is strictly related to a different level of exhaled hydrogen. Different sensor configurations using a metal-dielectric microcavity are reported and discussed in order to make the most of the well-known ability of palladium to spontaneously absorb hydrogen.

  4. Quantification of Helicobacter pylori infection in gastritis and ulcer disease using a simple and rapid carbon-14-urea breath test

    Energy Technology Data Exchange (ETDEWEB)

    Debongnie, J.C.; Pauwels, S.; Raat, A.; de Meeus, Y.; Haot, J.; Mainguet, P. (Department of Nuclear Medicine, University of Louvain Medical School, Brussels (Belgium))

    1991-06-01

    Gastric urease was studied isotopically in 230 patients with biopsy-proven normal mucosa or chronic gastritis, including 59 patients with ulcer disease. Carbon-14-urea was given in 25 ml of water without substrate carrier or nutrient-dense meal, and breath samples were collected over a 60-min period. The amount of 14CO2 excreted at 10 min was independent of the rate of gastric emptying and was not quantitatively influenced by the buccal urease activity. The 10-min 14CO2 values discriminated well between Helicobacter pylori positive and negative patients (94% sensitivity, 89% specificity) and correlated with the number of organisms assessed by histology. The test was a good predictor of chronic gastritis (95% sensitivity and 96% specificity), and a quantitative relationship was observed between 14CO2 values and the severity and activity of the gastritis. In H. pylori positive patients, breath 14CO2 was found to be similar in patients with and without ulcer disease, suggesting that the number of bacteria is not a determining factor for the onset of ulceration.

  5. Impaired gastric emptying of a solid test meal in patients with Parkinson's disease using 13C-sodium octanoate breath test.

    Science.gov (United States)

    Goetze, Oliver; Wieczorek, Joerg; Mueller, Thomas; Przuntek, Horst; Schmidt, Wolfgang E; Woitalla, Dirk

    2005-03-03

    Up to now gastric emptying in patients with Parkinson's disease was determined by radioscintigraphy. The 13C-sodium octanoate breath test (OBT) has been established for the non-invasive evaluation of gastric emptying with a solid test meal. The aim of the study was to evaluate the OBT in patients with Parkinson's disease and to investigate the prevalence of delayed gastric emptying for solids in PD and the relationship to clinical staging patterns. Twenty-two healthy subjects and 36 patients with different clinical stages of PD classified using Hoehn and Yahr (H&Y) and Unified Parkinson's Disease Rating Scale (UPDRS) were studied. Each fasting control and patient received a solid test meal (241 kcal) labelled with 100 mg of 13C-sodium octanoate. Breath samples were obtained before substrate administration and then in 15-min intervals over 4 h. The 13CO2/12CO2 ratio was determined in each breath sample as delta over baseline. Time to peak (t(peak)), gastric half emptying time (t1/2b), lag phase (t(lagb)) and gastric emptying coefficient (GEC) were calculated. Significant differences in t(peak), t1/2b, t(lagb) and GEC were found between patients and healthy volunteers (p<0.0001), with a 60% delay in gastric half emptying time in the patient group. Gastric half emptying time was different between clinical disease groups (H&Y 0-2 versus H&Y 2.5-5, p=0.001; UPDRS 0-30 versus UPDRS 61-92, p<0.05). The OBT detects a significant delay in gastric emptying of a solid test meal in patients with PD. Delayed gastric emptying for solids is associated with disease severity.

  6. Measurement of hepatic functional mass by means of 13C-methacetin and 13C-phenylalanine breath tests in chronic liver disease: Comparison with Child-Pugh score and serum bile acid levels

    Institute of Scientific and Technical Information of China (English)

    D. Festi; P. Portincasa; E. Roda; A. Colecchia; S. Capodicasa; L. Sandri; L. Colaiocco-Ferrante; T. Staniscia; E. Vitacolonna; A. Vestito; P. Simoni; G. Mazzella

    2005-01-01

    AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels.METHODS: One hundred and forty patients (50 HCV-related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated.RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids.Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test.CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients.

  7. Estimation of Insulin Resistance in Mexican Adults by the [13C]Glucose Breath Test Corrected for Endogenous Total CO2 Production

    Directory of Open Access Journals (Sweden)

    Erika Ibarra-Pastrana

    2012-01-01

    Full Text Available Objective. To evaluate the efficacy of the [13C]glucose breath test for measuring insulin resistance in Mexican adults with different glycemic states. Research Design and Methods. Fifty-eight adults underwent a [13C]glucose breath test with simultaneous measurement of total CO2 production by indirect calorimetry, at baseline and 90 minutes after the ingestion of 15 g of dextrose and 25 mg of [13C]glucose. HOMA was used as a marker of insulin resistance. Results. We found an inverse correlation between HOMA and the breath test δ13CO2 (‰, r=-0.41 (P=0.001. After adjusting for total CO2 production, correlations between HOMA and fasting glucose were less strong but remained significant. An ROC curve was constructed using δ13CO2 (‰ and HOMA values; the cut-off point was 9.99‰ δ13CO2, corresponding to a sensitivity of 80.0 (95% CI: 51.9, 95.7 and a specificity of 67.4 (95% CI: 51.5, 80.9. Conclusions. The [13C]glucose breath test is a simple noninvasive procedure but was not sufficiently robust for an accurate diagnosis of insulin resistance. Our findings suggest that the test might be helpful in identifying individuals who are not IR, which in turn may contribute to improved diabetes prevention.

  8. Can the C-14 urea breath test reflect the extent and degree of ongoing helicobacter pylori infection

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seok Tae; Sohn, Myung Hee; Lee, Seung Ok; Lee, Soo Taik; Jeong, Myung Ja [Chonbuk National Univ., Chonju (Korea, Republic of)

    2001-02-01

    The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). One hundred fifty patients (M:F=83:67,age 48.6{+-}11.2 yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive ({>=}200 dpm), intermediate ( 50 {approx} 199 dpm) or negative ( < 50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4(diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were 45 {+-} 27 dpm in grade 0, 707 {+-}584 dpm in grade 1, 1558{+-}584 dpm in grade 2, 1851{+-}604 dpm in grade 3, and 2719 {+-} 892 dpm in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  9. Validation in an animal model of the carbon 13-labeled mixed triglyceride breath test for the detection of intestinal fat malabsorption

    NARCIS (Netherlands)

    Kalivianakis, M; Elstrodt, J; Havinga, R; Kuipers, F; Stellaard, F; Sauer, PJJ; Vonk, RJ; Verkade, HJ

    1999-01-01

    Objective: To determine, in a rat model of fat malabsorption, the potency of the carbon 13-labeled mixed triglyceride (C-13-MTG) breath test as a noninvasive, patient-friendly replacement for classic fat balance studies, Study design: Comparison of the percentage of Fat absorption, detected by fat b

  10. Hydrogen breath test for the diagnosis of lactose intolerance, is the routine sugar load the best one?

    Institute of Scientific and Technical Information of China (English)

    Fiorenza Argnani; Mauro Di Camillo; Vanessa Marinaro; Tiziana Foglietta; Veronica Avallone; Carlo Cannella; Piero Vernia

    2008-01-01

    AIM: To evaluate the prevalence of lactose intolerance (LI) following a load of 12.5 g in patients diagnosed as high-grade malabsorbers using the hydrogen breath test (HBT)-25. METHODS: Ninety patients showing high-grade malabsorption at HBT-25 were submitted to a second HBT with a lactose load of 12.5 g. Peak hydrogen production, area under the curve of hydrogen excretion and occurrence of symptoms were recorded. RESULTS: Only 16 patients (17.77%) with positive HBT-25 proved positive at HBT-12.5. Hydrogen production was lower as compared to HBT-25 (peak value 21.55 parts per million (ppm)±29.54 SD vs 99.43 ppm±40.01 SD; P<0.001). Symptoms were present in only 13 patients. The absence of symptoms during the high-dose test has a high negative predictive value (0.84) for a negative low-dose test. The presence of symptoms during the first test was not useful for predicting a positive low-dose test (positive predictive value 0.06-0.31). CONCLUSION: Most patients with a positive HBT-25 normally absorb a lower dose of lactose and a strict lactose restriction on the basis of a "standard" HBT is, in most instances, unnecessary. Thus, the 25 g lactose tolerance test should probably be substituted by the 12.5 g test in the diagnosis of LI, and in providing dietary guidelines to patients with suspected lactose malabsorption/intolerance.

  11. Breath test for differential diagnosis between small intestinal bacterial overgrowth and irritable bowel disease: An observation on non-absorbable antibiotics

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To estimate the prevalence of small intestine bacterial overgrowth (SIBO) among patients with an earlier diagnosis of irritable bowel disease (IBS) in our geographical area, and to collect information on the use of locally acting non-absorbable antibiotics in the management of SIBO.METHODS: A non-interventional study was conducted in 73 consecutive patients with a symptom-based diagnosis..RESULTS: When the patients underwent a "breath test", 33 (45.2%) showed the presence of a SIBO. After treatment with rifaximin 1200 mg/d for seven days in 32 patients, 19 (59.4%) showed a negative "breath test" one week later as well as a significant reduction of symptoms, thus confirming the relationship between SIBO and many of the symptoms claimed by patients. In the other 13 patients, "breath test" remained positive,and a further cycle of treatment with ciprofloxacin 500mg/d was given for 7 additional days, resulting in a negative "breath test" in one atient only.CONCLUSION: (1) about half of the patients with a symptomatic diagnosis of IBS have actually SIBO, which is responsible for most of the symptoms attributed to IBS; (2) only a "breath test" with lactulose (or with glucose in subjects with an intolerance to lactose) can provide a differential diagnosis between IBS and SIBO,with almost identical symptoms; and (3) the use of non-absorbable antibiotics may be useful to reduce the degree of SIBO and related symptoms; it must be accompanied, however, by the correction of the wrong alimentary habits underlying SIBO.

  12. Measurement of Uncertainty for Aqueous Ethanol Wet-Bath Simulator Solutions Used with Evidential Breath Testing Instruments.

    Science.gov (United States)

    Hwang, Rong-Jen; Beltran, Jada; Rogers, Craig; Barlow, Jeremy; Razatos, Gerasimos

    2016-09-01

    Aqueous ethanol wet-bath simulator solutions are used to perform calibration adjustments, calibration checks, proficiency testing, and inspection of breath alcohol instruments. The Toxicology Bureau of the New Mexico Department of Health has conducted a study to estimate a measurement of uncertainty for the preparation and testing of these wet-bath simulator solutions. The measurand is identified as the mass concentration of ethanol (g/100 mL) determined through dual capillary column headspace gas chromatography with flame ionization detector analysis. Three groups were used in the estimation of the aqueous ethanol wet-bath simulator solutions uncertainty: GC calibration adjustment, GC analytical, and certified reference material. The standard uncertainties for these uncertainty sources were combined using the method of root-sum-squares to give uc = 0.8598%. The combined standard uncertainty was expanded to U = 1.7% to reflect a confidence level of 95% using a coverage factor of 2. This estimation applies to all aqueous ethanol wet-bath simulator solution concentrations produced by this laboratory.

  13. Testing Procedures for Closed-Circuit and Semi-Closed Circuit Underwater Breathing Apparatus

    Science.gov (United States)

    1974-01-29

    a water or mercury manometer prior to each major test. Recheck calibration at the end of the test. The flowmeters are factory calibrated and should...calibrated against a water or mercury manometer ; the thermisters against 321F. water and room temperature. c. The flowmeter and gauges normally do not need... mercury manometer ; the thermistors against 320 F water and room temperature. 3) The flowmeter and gauges normally do not need daily calibration. 4) All

  14. Liver breath tests non-invasively predict higher stages of non-alcoholic steatohepatitis

    NARCIS (Netherlands)

    Portincasa, Piero; Grattagliano, Ignazio; Lauterburg, Bernhard H.; Palmieri, Vincenzo O.; Palasciano, Giuseppe; Stellaard, Frans

    2006-01-01

    Effectively assessing subtle hepatic metabolic functions by novel non-invasive tests might be of clinical utility in scoring NAFLD (non-alcoholic fatty liver disease) and in identifying altered metabolic pathways. The present study was conducted on 39 (20 lean and 19 obese) hypertransaminasemic pati

  15. Intestinal transport and fermentation of resistant starch evaluated by the hydrogen breath test

    DEFF Research Database (Denmark)

    Olesen, M; Rumessen, J J; Gudmand-Høyer, E

    1994-01-01

    To study fermentability of different samples of resistant starch (RS), compared to one another and to lactulose, and to study the effect on gastric emptying of addition of RS to test meal. Finally to study if adaptation to RS results in a measurable change in fermentation pattern, (H2/CH4 product...... production). Sources of RS: Raw potato starch (RPS), 58% RS; corn flakes (CF), 5% RS; hylon VII high amylomaize starch, extrusion cooked and cooled (HAS) 30% RS; highly retrograded hylon VII high amylomaize starch (HRA) 89% RS.......To study fermentability of different samples of resistant starch (RS), compared to one another and to lactulose, and to study the effect on gastric emptying of addition of RS to test meal. Finally to study if adaptation to RS results in a measurable change in fermentation pattern, (H2/CH4...

  16. First-time urea breath tests performed at home by 36,629 patients

    DEFF Research Database (Denmark)

    Dahlerup, Søren; Andersen, Rikke Charlotte; Nielsen, Birgitte Sperling Wilms;

    2011-01-01

    , positive H. pylori declined over the time course of the study (women: 19.6% in 2003 to 17.6% in 2009, p H. pylori results than younger patients. CONCLUSIONS: A test......-and-treat system was possible to implement that allowed patients to perform UBTs at their homes. The results of the first-time UBTs demonstrated that approximately one of five patients who presented with dyspepsia in the clinical setting of Danish primary care was infected with H. pylori....

  17. Prognostic value of 13C-phenylalanine breath test on predicting survival in patients with chronic liver failure

    Institute of Scientific and Technical Information of China (English)

    I Gallardo-Wong; S Morán; G Rodríguez-Leal; B Casta(n)eda-Romero; R Mera; J Poo; M Uribe; M Dehesa

    2007-01-01

    AIM: To evaluate the prognostic value of percentage of 13C-phenylalanine oxidation (13C-PheOx) obtained by 13C-phenylalanine breath test (13C-PheBT) on the survival of patients with chronic liver failure.METHODS: The hepatic function was determined by standard liver blood tests and the percentage of 13C-PheOx in 118 chronic liver failure patients. The follow-up period was of 64 mo. Survival analysis was performed by the Kaplan-Meier method and variables that were significant (P < 0.10) in univariate analysis and subsequently introduced in a multivariate analysis according to the hazard model proposed by Cox.RESULTS: Forty-one patients died due to progressive liver failure during the follow-up period. The probability of survival at 12, 24, 36, 48 and 64 mo was 0.88, 0.78,0.66, 0.57 and 0.19, respectively. Multivariate analysis demonstrated that Child-Pugh classes, age, creatinine and the percentage of 13C-PheOx (HR 0.338, 95% CI:0.150-0.762, P = 0.009) were independent predictors of survival. When Child-Pugh classes were replaced by all the parameters of the score, only albumin, bilirubin,creatinine, age and the percentage of 13C-PheOx (HR 0.449, 95% CI: 0.206-0.979, P = 0.034) were found to be independent predictors of survival.CONCLUSION: Percentage of 13C-PheOx obtained by 13C-PheBT is a strong predictor of survival in patients with chronic liver disease.

  18. Evaluation of CYP2D6 enzyme activity using a Dextromethorphan Breath Test in Women Receiving Adjuvant Tamoxifen

    Science.gov (United States)

    Safgren, Stephanie L.; Suman, Vera J.; Kosel, Matthew L.; Gilbert, Judith A; Buhrow, Sarah A.; Black, John L.; Northfelt, Donald W.; Modak, Anil S.; Rosen, David; Ingle, James N.; Ames, Matthew M.; Reid, Joel M.; Goetz, Matthew P.

    2015-01-01

    Background In tamoxifen-treated patients, breast cancer recurrence differs according to CYP2D6 genotype and endoxifen steady state concentrations (Endx Css). The 13Cdextromethorphan breath test (DM-BT), labeled with 13C at the O-CH3 moiety, measures CYP2D6 enzyme activity. We sought to examine the ability of the DM-BT to identify known CYP2D6 genotypic poor metabolizers and examine the correlation between DMBT and Endx Css. Methods DM-BT and tamoxifen pharmacokinetics were obtained at baseline (b), 3 month (3m) and 6 months (6m) following tamoxifen initiation. Potent CYP2D6 inhibitors were prohibited. The correlation between bDM-BT with CYP2D6 genotype and Endx Css was determined. The association between bDM-BT (where values ≤0.9 is an indicator of poor in vivo CYP2D6 metabolism) and Endx Css (using values ≤ 11.2 known to be associated with poorer recurrence free survival) was explored. Results 91 patients were enrolled and 77 were eligible. CYP2D6 genotype was positively correlated with b, 3m and 6m DMBT (r ranging from 0.457-0. 60 p 11.2 nM. Conclusions In patients not taking potent CYP2D6 inhibitors, DM-BT was associated with CYP2D6 genotype and 3m and 6 m Endx Css but did not provide better discrimination of Endx Css compared to CYP2D6 genotype alone. Further studies are needed to identify additional factors which alter Endx Css. PMID:25714002

  19. An anthropomorphic breathing phantom of the thorax for testing new motion mitigation techniques for pencil beam scanning proton therapy

    Science.gov (United States)

    Perrin, R. L.; Zakova, M.; Peroni, M.; Bernatowicz, K.; Bikis, C.; Knopf, A. K.; Safai, S.; Fernandez-Carmona, P.; Tscharner, N.; Weber, D. C.; Parkel, T. C.; Lomax, A. J.

    2017-03-01

    Motion-induced range changes and incorrectly placed dose spots strongly affect the quality of pencil-beam-scanned (PBS) proton therapy, especially in thoracic tumour sites, where density changes are large. Thus motion-mitigation techniques are necessary, which must be validated in a realistic patient-like geometry. We report on the development and characterisation of a dynamic, anthropomorphic, thorax phantom that can realistically mimic thoracic motions and anatomical features for verifications of proton and photon 4D treatments. The presented phantom is of an average thorax size, and consists of inflatable, deformable lungs surrounded by a skeleton and skin. A mobile ‘tumour’ is embedded in the lungs in which dosimetry devices (such as radiochromic films) can be inserted. Motion of the tumour and deformation of the thorax is controlled via a custom made pump system driving air into and out of the lungs. Comprehensive commissioning tests have been performed to evaluate the mechanical performance of the phantom, its visibility on CT and MR imaging and its feasibility for dosimetric validation of 4D proton treatments. The phantom performed well on both regular and irregular pre-programmed breathing curves, reaching peak-to-peak amplitudes in the tumour of  feasible with Gamma Index agreements (4%/4 mm) between film dose and planned dose  >90% in the central planes of the target. The results of this study demonstrate that this anthropomorphic thorax phantom is suitable for imaging and dosimetric studies in a thoracic geometry closely-matched to lung cancer patients under realistic motion conditions.

  20. Rapid shallow breathing

    Science.gov (United States)

    Tachypnea; Breathing - rapid and shallow; Fast shallow breathing; Respiratory rate - rapid and shallow ... Shallow, rapid breathing has many possible medical causes, including: Asthma Blood clot in an artery in the lung Choking Chronic obstructive ...

  1. Breathing difficulties - first aid

    Science.gov (United States)

    Difficulty breathing - first aid; Dyspnea - first aid; Shortness of breath - first aid ... Breathing difficulty is almost always a medical emergency. An exception is feeling slightly winded from normal activity, ...

  2. Validation of the string test for the recovery of Helicobacter pylori from gastric secretions and correlation of its results with urea breath test results, serology, and gastric pH levels.

    Science.gov (United States)

    Torres, J; Camorlinga, M; Pérez-Peréz, G; Gonzalez, G; Muñoz, O

    2001-04-01

    The efficacy of the string culture test to isolate Helicobacter pylori from gastric secretions of 28 volunteers was studied. With the urea breath test (UBT) as the "gold standard," the string culture test showed a sensitivity of 75% and a specificity of 100%. The results of string culture did not correlate with the UBT results, with serum antibody levels, or with the pH levels of gastric secretions.

  3. Early functional recovery for a graft after hepatic transplantation: interest of the aminopyrine-{sup 13}C breath test; Reprise precoce de fonction du greffon apres transplantation hepatique: interet du test respiratoire a l`aminopyrine-{sup 13}C

    Energy Technology Data Exchange (ETDEWEB)

    Mion, F.; Queneau, P.E.; Boillot, O.; Minaire, Y.; Delafosse, B. [Hopital Edouard-Herriot, 69 - Lyon (France); Rousseau, M. [Inbiomed, 69 - Lyon (France); Brazier, J.L. [LEACM, 69 - Lyon (France)

    1994-12-31

    {sup 13}C-aminopyrine breath tests were carried out on 8 patients, just after liver transplantation, in order to examine the recovery of the graft metabolic functions. Test results are compared to usual data from hepatic biology and histology. Quantitative measures on hepatic functional mass are obtained. The relative sensitivity of the test could allow for detection of moderate hepatic dysfunctions. 4 figs., 8 refs.

  4. Point-of-care continuous 13C-methacetin breath test improves decision making in acute liver disease: Results of a pilot clinical trial

    Institute of Scientific and Technical Information of China (English)

    Gadi Lalazar; Tomer Adar; Yaron Ilan

    2009-01-01

    AIM: To assess the role of the 13C-methacetin breath test (MBT) in patients with acute liver disease. METHODS: Fifteen patients with severe acute liver disease from diverse etiologies were followed-up with 13C-MBT during the acute phase of their illnesses (range 3-116 d after treatment). Patients fasted for 8 h and ingested 75 mg of methacetin prior to the MBT. We compared results from standard clinical assessment, serum liver enzymes, synthetic function, and breath test scores. RESULTS: Thirteen patients recovered and two patients died. In patients that recovered, MBT parameters improved in parallel with improvements in lab results. Evidence of consistent improvement began on day 3 for MBT parameters and between days 7 and 9 for blood tests. Later convergence to normality occurred at an average of 9 d for MBT parameters and from 13 to 28 d for blood tests. In both patients that died, MBT parameters remained low despite fluctuating laboratory values. CONCLUSION: The 13C-MBT provides a rapid, noninvasive assessment of liver function in acute severe liver disease of diverse etiologies. The results of this pilot clinical trial suggest that the MBT may offer greater sensitivity than standard clinical tests for managing patients with severe acute liver disease.

  5. Utility of the wireless motility capsule and lactulose breath testing in the evaluation of patients with Parkinson's disease who present with functional gastrointestinal symptoms

    Science.gov (United States)

    Su, Andrew; Gandhy, Rita; Barlow, Carrolee; Triadafilopoulos, George

    2017-01-01

    Background The aetiology and origin of gastrointestinal symptoms in Parkinson's disease (PD) remains poorly understood. Gastroparesis, small bowel transit delay and bacterial overgrowth may, individually or collectively, play a role. Aims In patients with PD and functional gastrointestinal symptoms, we aimed to determine the utility of the wireless motility capsule and lactulose breath tests in further defining their symptoms' aetiology. Methods In this retrospective cohort study, consecutive patients with PD and functional gastrointestinal symptoms underwent clinical assessment, as well as wireless motility capsule and lactulose breath testing using standard protocols. Results We studied 65 patients with PD and various gastrointestinal symptoms. 35% exhibited gastroparesis by the wireless motility capsule study, 20% small bowel transit delay, while 8% had combined transit abnormalities, suggestive of overlapping gastric and small bowel dysmotility. Small bowel bacterial overgrowth was seen in 34% of cases. Symptoms of abdominal pain, regurgitation, bloating, nausea, vomiting, belching and weight loss could not distinguish between patients with or without gastroparesis, although bloating was significantly more prominent (p<0.001) overall and specifically more so in patients with slow small bowel transit (p<0.01). There was no relationship between delayed small bowel transit time and bacterial overgrowth (p=0.5); PD scores and duration were not correlated with either the transit findings or small bowel bacterial overgrowth. Conclusions Functional gastrointestinal symptoms in patients with PD may reflect gastroparesis, small bowel transit delay or both, suggesting motor and/or autonomic dysfunction, and may be associated with small bowel bacterial overgrowth. The wireless motility capsule and lactulose breath testing are non-invasive and useful in the assessment of these patients.

  6. Teste de caminhada e rendimento escolar em crianças respiradoras bucais Walk test and school performance in mouth-breathing children

    Directory of Open Access Journals (Sweden)

    Ana Paula Dias Vilas Boas

    2013-04-01

    Full Text Available Nas últimas décadas, vários trabalhos sobre respiração bucal (RB têm surgido na literatura; em contrapartida, pouco se conhece sobre vários aspectos desta síndrome, incluindo gravidade, repercussões sobre o rendimento físico e escolar. OBJETIVO: Comparar o rendimento físico pelo teste de caminhada de seis minutos (TC6' e rendimento escolar de crianças e adolescentes com RB e respiradores nasais (RN. MÉTODO: Estudo de corte transversal descritivo e prospectivo em crianças RB e RN que foram submetidas ao TC6' e avaliação do rendimento escolar. RESULTADOS: Foram incluídos 156 escolares, 87 meninas (60 RN e 27 RB e 69 meninos (44 RN e 25 RB. Foram analisadas variáveis durante o TC6': frequência cardíaca (FC, frequência respiratória, saturação periférica de oxigênio, distância percorrida em seis minutos e escala de Borg modificada. Todos os valores das variáveis estudadas foram estatisticamente diferentes entre os grupos RB e RN, com exceção do rendimento escolar e FC no TC6'. CONCLUSÃO: A RB afeta o rendimento físico e não o rendimento escolar, sendo observado padrão alterado no TC6' no grupo RB. Uma vez que os RB desse estudo foram classificados como não graves outros estudos comparando as variáveis de rendimento escolar e TC6' são necessários para o melhor entendimento do processo dos desempenhos físico e escolar em crianças com RB.In recent decades, many studies on mouth breathing (MB have been published; however, little is known about many aspects of this syndrome, including severity, impact on physical and academic performances. OBJECTIVE: Compare the physical performance in a six minutes walk test (6MWT and the academic performance of MB and nasal-breathing (NB children and adolescents. METHOD: This is a descriptive, cross-sectional, and prospective study with MB and NB children submitted to the 6MWT and scholar performance assessment. RESULTS: We included 156 children, 87 girls (60 NB and 27 MB and 69

  7. SU-D-BRE-01: A Realistic Breathing Phantom of the Thorax for Testing New Motion Mitigation Techniques with Scanning Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, R; Peroni, M; Bernatowicz, K; Zakova, M; Knopf, A; Safai, S [Paul Scherrer Institut, Psi-villigen, Aargau (Switzerland); Parkel, T [CSEM, Swiss Centre of Electronics and Microtechnology, Landquart, Graubunden (Switzerland)

    2014-06-01

    Purpose: A prototype breathing phantom (named LuCa) has been developed which simulates the anatomy and motion of a patient thorax.In this work, we describe the results of the first commissioning tests with LuCa. Methods: The phantom provides a close representation of the human thorax. The lungs,contained within a tissue-equivalent ribcage and skin,are made from a polymer foam,which is inflated and deflated using a custommade ventilator. A tumor is simulated using a wooden ball with cutplanes for placing GafChromic films. The ventilator,controlled with Labview software,simulates a full range of breathing motion types.Commissioning tests were performed to assess its performance using imaging (CT and radiographic) and film dosimetry as follows:i)maximum Tumor excursion at acceptable pressure ranges, ii)tumor Motion repeatability between breathing periods,iii)reproducibility between measurement days,iv)tumor-to-surface motion correlation and v)reproducibility of film positioning in phantom. Results: The phantom can generate repeatable motion patterns with sin{sup 4},sin,breath-hold (tumor amplitude repeatability <0.5mm over 10min),aswell as patient-specific motion types. Maximum excursions of the tumor are 20mm and 14mm for the large and small tumor inserts respectively. Amplitude reproducibility (Coefficient of Variation) averaged at 16% for the workable pressure range over 2 months. Good correlation between tumor and surface motion was found with R{sup 2}=0.92. Reproducibility of film positioning within the thorax was within 0.9mm, and maximum 3° error from the coronal plane. Film measurements revealed that the film repositioning error yields relative errors in the mean dose over the planned target volume (PTV) of up to 2.5% and 4.5% for films at the center and on the edge of the PTV respectively. Conclusion: Commissioning tests have shown that the LuCa phantom can produce tumor motion with excellent repeatability. However,a poorer performance in reproducibility of

  8. Effects of Ergot Alkaloids on Liver Function of Piglets as Evaluated by the 13C-Methacetin and 13C-α-Ketoisocaproic Acid Breath Test

    Directory of Open Access Journals (Sweden)

    Sonja Diers

    2013-01-01

    Full Text Available Ergot alkaloids (the sum of individual ergot alkaloids are termed as total alkaloids, TA are produced by the fungus Claviceps purpurea, which infests cereal grains commonly used as feedstuffs. Ergot alkaloids potentially modulate microsomal and mitochondrial hepatic enzymes. Thus, the aim of the present experiment was to assess their effects on microsomal and mitochondrial liver function using the 13C-Methacetin (MC and 13C-α-ketoisocaproic acid (KICA breath test, respectively. Two ergot batches were mixed into piglet diets, resulting in 11 and 22 mg (Ergot 5-low and Ergot 5-high, 9 and 14 mg TA/kg (Ergot 15-low and Ergot 15-high and compared to an ergot-free control group. Feed intake and live weight gain decreased significantly with the TA content (p < 0.001. Feeding the Ergot 5-high diet tended to decrease the 60-min-cumulative 13CO2 percentage of the dose recovery (cPDR60 by 26% and 28% in the MC and KICA breath test, respectively, compared to the control group (p = 0.065. Therefore, both microsomal and mitochondrial liver function was slightly affected by ergot alkaloids.

  9. CO2呼气试验和 H2呼气试验的临床应用%Clinical Applications of CO2 and H2 Breath Test

    Institute of Scientific and Technical Information of China (English)

    赵思倩; 陈宝军; 罗志福

    2016-01-01

    呼气试验简单无创、灵敏度高、特异性较强,受到研究者的关注。本文介绍了CO2呼气试验和 H2呼气试验的临床应用。CO2呼气试验的主要应用有胃幽门螺杆菌检测、肝功能检测、胃排空检测、胰岛素抵抗检测和胰腺外分泌测定等。 H2呼气试验可用于诊断乳糖吸收不良和检测小肠细菌过度生长。随着进一步的研究,呼气试验因其高灵敏度,非侵入性,有望应用于更多疾病的诊断。%Breath test is non‐invasive ,high sensitivity and high specificity .In this arti‐cle ,CO2 breath test ,H2 breath test and their clinical applications were elaborated .The main applications of CO2 breath test include helicobacter pylori test , liver function detection ,gastric emptying test ,insulin resistance test ,pancreatic exocrine secretion test ,etc .H2 breath test can be applied in the diagnosis of lactose malabsorption and detecting small intestinal bacterial overgrow th .With further research ,the breath test is expected to be applied in more diseases diagnosis .

  10. News from the Breath Analysis Summit 2011.

    Science.gov (United States)

    Corradi, Massimo; Mutti, Antonio

    2012-06-01

    This special section highlights some of the important work presented at the Breath Analysis Summit 2011, which was held in Parma (Italy) from 11 to 14 September 2011. The meeting, which was jointly organized by the International Association for Breath Research and the University of Parma, was attended by more than 250 delegates from 33 countries, and offered 34 invited lectures and 64 unsolicited scientific contributions. The summit was organized to provide a forum to scientists, engineers and clinicians to present their latest findings and to meet industry executives and entrepreneurs to discuss key trends, future directions and technologies available for breath analysis. A major focus was on nitric oxide, exhaled breath condensate, electronic nose, mass spectrometry and newer sensor technologies. Medical applications ranged from asthma and other respiratory diseases to gastrointestinal disease, occupational diseases, critical care and cancer. Most people identify breath tests with breathalysers used by police to estimate ethanol concentration in blood. However, breath testing has far more sophisticated applications. Breath analysis is rapidly evolving as a new frontier in medical testing for disease states in the lung and beyond. Every individual has a breath fingerprint-or 'breathprint'-that can provide useful information about his or her state of health. This breathprint comprises the many thousands of molecules that are expelled with each breath we exhale. Breath research in the past few years has uncovered the scientific and molecular basis for such clinical observations. Relying on mass spectrometry, we have been able to identify many such unique substances in exhaled breath, including gases, such as nitric oxide (NO) and carbon monoxide (CO), and a wide array of volatile organic compounds. Exhaled breath also carries aerosolized droplets that can be collected as an exhaled breath condensate that contains endogenously produced non-volatile compounds. Breath

  11. Is Hydrogen Breath Test with Lactulose Feasible for Measuring Gastrocecal Transit in Critically Ill Children? Pilot Study about Modification of the Technique

    Science.gov (United States)

    Sánchez, C.; González, R.; Solana, M. J.; Urbano, J.; Tolín, M.

    2017-01-01

    Introduction. Gastrocecal transit time (GCTT) can be measured by exhaled hydrogen after lactulose intake (lactulose-eH2 test). The objectives were to assess whether it is possible to carry out this test in critically ill children with and without mechanical ventilation (MV) and to analyze whether the results are consistent with clinical findings. Methods. Patients admitted to the Pediatric Intensive Care Unit (PICU) for more than 3 days were included. Those with gastrointestinal disease prior to admission were excluded. A modified technique to obtain eH2 from the ventilator tubes was performed. Results. Sixteen patients (37.5% boys) with a median age of 19 (5–86.5) months were included. Five patients (31.2%) were breathing spontaneously but lactulose-eH2 test could not be performed while it could be performed successfully in the 11 patients with MV. Seven patients (63.3%) did not show an eH2 peak. The other 4 showed a median time of 130 min (78.7–278.7 min) from lactulose intake to a 10 ppm eH2 peak. Children with an eH2 peak had intestinal movements earlier [6.5 (1.5–38.5) versus 44 (24–72) hours p = 0.545]. Conclusion. Although the designed adaption is useful for collecting breath samples, lactulose-eH2 test may not be useful for measuring GCTT in critically ill children. PMID:28246601

  12. What Causes Bad Breath?

    Science.gov (United States)

    ... A Week of Healthy Breakfasts Shyness What Causes Bad Breath? KidsHealth > For Teens > What Causes Bad Breath? A A A en español ¿Qué es lo que provoca el mal aliento? Bad breath, or halitosis , can be a major problem, ...

  13. Application of LaserBreath-001 for breath acetone measurement in subjects with diabetes mellitus

    Science.gov (United States)

    Wang, Zhennan; Sun, Meixiu; Chen, Zhuying; Zhao, Xiaomeng; Li, Yingxin; Wang, Chuji

    2016-11-01

    Breath acetone is a promising biomarker of diabetes mellitus. With an integrated standalone, on-site cavity ringdown breath acetone analyzer, LaserBreath-001, we tested breath samples from 23 type 1 diabetic (T1D) patients, 312 type 2 diabetic (T2D) patients, 52 healthy subjects. In the cross-sectional studies, the obtained breath acetone concentrations were higher in the diabetic subjects compared with those in the control group. No correlation between breath acetone and simultaneous BG was observed in the T1D, T2D, and healthy subjects. A moderate positive correlation between the mean individual breath acetone concentrations and the mean individual BG levels was observed in the 20 T1D patients without ketoacidosis. In a longitudinal study, the breath acetone concentrations in a T1D patient with ketoacidosis decreased significantly and remained stable during the 5-day hospitalization. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone concentrations, fast (diabetic screening and management under a specifically controlled condition.

  14. Ontogeny and nutritional status influence oxidative kinetics of nutrients and whole-animal bioenergetics in zebra finches, Taeniopygia guttata: new applications for (13)C breath testing.

    Science.gov (United States)

    McCue, Marshall D; McWilliams, Scott R; Pinshow, Berry

    2011-01-01

    Rapidly growing animals or those that are recovering from nutritional stress may use exogenous nutrients differently from well fed adults. To test this possibility, we compared the rates of exogenous nutrient oxidation among fledgling, fasted adult, and refed adult zebra finches using a technique called breath testing, where animals are fed (13)C-labeled nutrients and (13)C in the exhaled breath is collected and quantified. In order to identify the possible mechanisms responsible for differences in oxidative kinetics of ingested nutrients, we also compared body mass (m(b)), organ mass, core body temperature (T(b)), and metabolic rate (MR). We found that fasted birds had lower T(b), relative liver and intestine masses, MR, and respiratory exchange ratios (RERs) than fed adults. Adult birds recovering from nutritional stress had much lower rates of exogenous nutrient oxidation than fed birds; this difference was particularly evident for fatty acids. Differences in oxidative kinetics were correlated with reduced RER, m(b), and liver mass, suggesting that previously fasted birds were using recently assimilated nutrients to replenish exhausted fuel stores. Rapidly growing fledglings oxidized exogenous nutrients as quickly as fed adults, despite their significantly lower m(b) and T(b). We suggest that fledglings had higher mass-specific rates of exogenous nutrient oxidation because they must compensate for the relatively low conversion efficiency of feather production and other lean tissue growth, which was not taking place in the adults. Although this study demonstrates that ontogeny and nutritional status influence the way that birds oxidize exogenous nutrients, it also underscores the likelihood that environmental and endogenous factors shape how other types of animals spend the nutrients they ingest.

  15. Prevalence of Helicobacter Pylori Infection in School and Pre-School Aged Children with C-14 Urea Breath Test and the Association with Familial and Environmental Factors

    Directory of Open Access Journals (Sweden)

    Alev Çınar

    2015-06-01

    Full Text Available Objective: To investigate the prevalence of Helicobacter pylori (Hp infection in pre-school and school age children with C-14 urea breath test, and to explore its association with age and socioeconomic factors in Turkey. Methods: Hp infection status was determined by using Urea Breath Test (UBT. Patients who had previous gastric surgery, Hp eradication treatment or equivocal UBT results were excluded. A questionnaire was administered to elicit information on gender, age, ABO/Rh blood group type, presence of gastric disease in the family, domestic animal in the household, and treatment for idiopathic Iron Deficiency Anemia (IDA. Results: This retrospective study included 500 pediatric patients (179 boys, 321 girls, mean age 10.7±4.3 years of whom 62 (12.4% were aged ≤6 years and 438 (87.6% were aged 7 to 16 years. Helicobacter pylori (Hp was positive in 245 (49% cases. In the pre-school age group, 21/62 cases (34% had positive UBT while in the school age group 224/438 children (51% had positive UBT. A family history of dyspepsia and pet ownership were not associated with Hp positivity. Hp positive 76 (29.8% children were on IDA treatment but this was not statistically significant. Conclusion: The Hp infection positivity rate was 49% in the pediatric age study group. The positivity rate was significantly lower at preschool age than school age, and it increased with age. There was no association with gender, ABO/Rh blood groups, presence of domestic pets, IDA, or history of gastric disease in the family.

  16. The non-invasive 13C-methionine breath test detects hepatic mitochondrial dysfunction as a marker of disease activity in non-alcoholic steatohepatitis

    Directory of Open Access Journals (Sweden)

    Banasch M

    2012-06-01

    Full Text Available Abstract Introduction Mitochondrial dysfunction plays a central role in the general pathogenesis of non-alcoholic fatty liver disease (NAFLD, increasing the risk of developing steatosis and subsequent hepatocellular inflammation. We aimed to assess hepatic mitochondrial function by a non-invasive 13C-methionine breath test (MeBT in patients with histologically proven NAFLD. Methods 118 NAFLD-patients and 18 healthy controls were examined by MeBT. Liver biopsy specimens were evaluated according to the NASH scoring system. Results Higher grades of NASH activity and fibrosis were independently associated with a significant decrease in cumulative 13C-exhalation (expressed as cPDR(%. cPDR1.5h was markedly declined in patients with NASH and NASH cirrhosis compared to patients with simple steatosis or borderline diagnosis (cPDR1.5h: 3.24 ± 1.12% and 1.32 ± 0.94% vs. 6.36 ± 0.56% and 4.80 ± 0.88% respectively; p 13C-exhalation further declined in the presence of advanced fibrosis which was correlated with NASH activity (r = 0.36. The area under the ROC curve (AUROC for NASH diagnosis was estimated to be 0.87 in the total cohort and 0.83 in patients with no or mild fibrosis (F0-1. Conclusion The 13C-methionine breath test indicates mitochondrial dysfunction in non-alcoholic fatty liver disease and predicts higher stages of disease activity. It may, therefore, be a valuable diagnostic addition for longitudinal monitoring of hepatic (mitochondrial function in non-alcoholic fatty liver disease.

  17. [Quantification of the drug-metabolizing enzyme system in liver diseases: a comparison between antipyrine saliva clearance and the aminopyrine breath test].

    Science.gov (United States)

    von Mandach, U; Jost, G; Preisig, R

    1985-05-11

    The metabolic activity of the hepatic cytochrome P450 system was studied in 53 ambulatory subjects. 18 of these were cirrhotics and 23 had non-cirrhotic liver disease, documented by biopsy, serologic, ultrasound or computerized tomography findings, and characterized by quantitative liver function tests, such as galactose elimination capacity and indocyanine green fractional clearance. For comparison, 12 normal control subjects were also included. All subjects were given 10 mg/kg body weight antipyrine and saliva concentrations determined with an HPLC-method at 24 and 48 hours after dosing. Antipyrine saliva clearance (ASC) was calculated according to a two-point method (Cl1), and compared with a one-point method (Cl2) using the 24 h sample only. These subjects also underwent an aminopyrine breath test (ABT), breath samples being collected at regular intervals during 60 minutes following injection of a tracer dose of 1.5 muCi (14C-dimethylamino)antipyrine. Cl1 and Cl2 correlated strongly (r = 0.93). On the basis of smaller variations (particularly in control subjects), better definition of disease severity and convenience and time saving, Cl2 is to be preferred. Comparison of Cl2 with ABT showed that both procedures apparently quantify overlapping enzymatic activities. However, the relationship between Cl2 and ABT values, albeit highly significant (r = 0.72), suggests that only about half of the variables are subject to the same determinant. In addition, a positive intercept of the regression line extrapolated to the Cl2 axis points to quantitatively important extrahepatic breakdown of antipyrine. The results suggest that, in view of the wide variation in normal values (presumably in part influenced by exogenous pollutants), ASC only provides an approximation of hepatic metabolic activity.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. The 13C-Glucose Breath Test for Insulin Resistance Assessment in Adolescents: Comparison with Fasting and Post-Glucose Stimulus Surrogate Markers of Insulin Resistance

    Science.gov (United States)

    Maldonado-Hernández, Jorge; Martínez-Basila, Azucena; Salas-Fernández, Alejandra; Navarro-Betancourt, José R.; Piña-Aguero, Mónica I.; Bernabe-García, Mariela

    2016-01-01

    Objective: To evaluate the use of the 13C-glucose breath test (13C-GBT) for insulin resistance (IR) detection in adolescents through comparison with fasting and post-glucose stimulus surrogates. Methods: One hundred thirty-three adolescents aged between 10 and 16 years received an oral glucose load of 1.75 g per kg of body weight dissolved in 150 mL of water followed by an oral dose of 1.5 mg/kg of U-13C-Glucose, without a specific maximum dose. Blood samples were drawn at baseline and 120 minutes, while breath samples were obtained at baseline and at 30, 60, 90, 120, 150, and 180 minutes. The 13C-GBT was compared to homeostasis model assessment (HOMA) IR (≥p95 adjusted by gender and age), fasting plasma insulin (≥p90 adjusted by gender and Tanner stage), results of 2-h oral glucose tolerance test (OGTT), insulin levels (≥65 μU/mL) in order to determine the optimal cut-off point for IR diagnosis. Results: 13C-GBT data, expressed as adjusted cumulative percentage of oxidized dose (A% OD), correlated inversely with fasting and post-load IR surrogates. Sexual development alters A% OD results, therefore individuals were stratified into pubescent and post-pubescent. The optimal cut-off point for the 13C-GBT in pubescent individuals was 16.3% (sensitivity=82.8% & specificity=60.6%) and 13.0% in post-pubescents (sensitivity=87.5% & specificity=63.6%), when compared to fasting plasma insulin. Similar results were observed against HOMA and 2-h OGTT insulin. Conclusion: The 13C-GBT is a practical and non-invasive method to screen for IR in adolescents with reasonable sensitivity and specificity. PMID:27354200

  19. Lactose tolerance tests

    Science.gov (United States)

    Hydrogen breath test for lactose tolerance ... Two common methods include: Lactose tolerance blood test Hydrogen breath test The hydrogen breath test is the preferred method. It measures the amount of hydrogen ...

  20. Diagnosis of adult-type hypolactasia/lactase persistence: genotyping of single nucleotide polymorphism (SNP C/T-13910 is not consistent with breath test in Colombian Caribbean population

    Directory of Open Access Journals (Sweden)

    Evelyn Mendoza Torres

    2012-03-01

    Full Text Available CONTEXT: Genotyping of single nucleotide polymorphism (SNP C/T-13910 located upstream of the lactase gene is used to determine adult-type hypolactasia/lactase persistence in North-European Caucasian subjects. The applicability of this polymorphism has been studied by comparing it with the standard diagnostic methods in different populations. OBJECTIVE: To compare the lactose hydrogen breath test with the genetic test in a sample of the Colombian Caribbean population. METHODS: Lactose hydrogen breath test and genotyping of SNP C/T-13910 were applied to 128 healthy individuals (mean age 35 ± 1. A positive lactose hydrogen breath test was indicative of hypolactasia. Genotyping was done using polymerase chain reaction/restriction fragment length polymorphism. The kappa index was used to establish agreement between the two methods. RESULTS: Seventy-six subjects (59% were lactose-maldigesters (hypolactasia and 52 subjects (41% were lactose-digesters (lactase persistence. The frequencies of the CC, CT and TT genotypes were 80%, 20% and 0%, respectively. Genotyping had 97% sensitivity and 46% specificity. The kappa index = 0.473 indicates moderate agreement between the genotyping of SNP C/T-13910 and the lactose hydrogen breath test. CONCLUSION: The moderate agreement indicates that the genotyping of the SNP C/T-13910 is not applicable to determine adult-type hypolactasia/lactase persistence in the population participating in this study.

  1. From breathing to respiration.

    Science.gov (United States)

    Fitting, Jean-William

    2015-01-01

    The purpose of breathing remained an enigma for a long time. The Hippocratic school described breathing patterns but did not associate breathing with the lungs. Empedocles and Plato postulated that breathing was linked to the passage of air through pores of the skin. This was refuted by Aristotle who believed that the role of breathing was to cool the heart. In Alexandria, breakthroughs were accomplished in the anatomy and physiology of the respiratory system. Later, Galen proposed an accurate description of the respiratory muscles and the mechanics of breathing. However, his heart-lung model was hampered by the traditional view of two non-communicating vascular systems - veins and arteries. After a period of stagnation in the Middle Ages, knowledge progressed with the discovery of pulmonary circulation. The comprehension of the purpose of breathing progressed by steps thanks to Boyle and Mayow among others, and culminated with the contribution of Priestley and the discovery of oxygen by Lavoisier. Only then was breathing recognized as fulfilling the purpose of respiration, or gas exchange. A century later, a controversy emerged concerning the active or passive transfer of oxygen from alveoli to the blood. August and Marie Krogh settled the dispute, showing that passive diffusion was sufficient to meet the oxygen needs.

  2. Decreased chewing activity during mouth breathing.

    Science.gov (United States)

    Hsu, H-Y; Yamaguchi, K

    2012-08-01

    This study examined the effect of mouth breathing on the strength and duration of vertical effect on the posterior teeth using related functional parameters during 3 min of gum chewing in 39 nasal breathers. A CO(2) sensor was placed over the mouth to detect expiratory airflow. When no airflow was detected from the mouth throughout the recording period, the subject was considered a nasal breather and enrolled in the study. Electromyographic (EMG) activity was recorded during 3 min of gum chewing. The protocol was repeated with the nostrils occluded. The strength of the vertical effect was obtained as integrated masseter muscle EMG activity, and the duration of vertical effect was also obtained as chewing stroke count, chewing cycle variation and EMG activity duration above baseline. Baseline activity was obtained from the isotonic EMG activity during jaw movement at 1.6 Hz without making tooth contact. The duration represented the percentage of the active period above baseline relative to the 3-min chewing period. Paired t-test and repeated analysis of variance were used to compare variables between nasal and mouth breathing. The integrated EMG activity and the duration of EMG activity above baseline, chewing stroke count and chewing cycle significantly decreased during mouth breathing compared with nasal breathing (Pmouth breathing was significantly greater than nasal breathing (PMouth breathing reduces the vertical effect on the posterior teeth, which can affect the vertical position of posterior teeth negatively, leading to malocclusion.

  3. Fast-starting for a breath: Air breathing in Hoplosternum littorale

    DEFF Research Database (Denmark)

    Domenici, Paolo; Norin, Tommy; Bushnell, Peter G.

    by the fall of a prey item on the water surface, and in tapping motions of goldfish, a behaviour that was interpreted to be food-related. Little is known about C-starts being used outside the context of escaping or feeding. Here, we test the hypothesis that air-breathing fish may use C-starts when gulping air...... at the surface. Air breathing is a common behaviour in many fish species when exposed to hypoxia, although certain species perform air-breathing in normoxia to fill their swim bladders for buoyancy control and/or sound transduction. Hoplosternum littorale is an air-breathing freshwater catfish found in South......, with those of mechanically-triggered C-start escape responses. Our results show that these two behaviours overlap considerably in their kinematics (turning rates and distance covered), suggesting that air breathing in this species is performed using escapelike C-start motions. This demonstrates that C...

  4. An introduction to the psychophysiology of breathing.

    Science.gov (United States)

    Ley, R

    1994-06-01

    Breathing can be viewed as an independent variable which affects emotion, cognition, and behavior as well as a dependent variable which reflects changes in emotion, cognition, and behavior. This bidirectional interaction is basic to an appreciation of the significance of breathing in terms of its relevance in research and application. The underlying premise of the present article is that since breathing is a behavior that is under voluntary as well as reflexive control, it can be modified according to the principles of both instrumental training (operant conditioning) and Pavlovian (classical) conditioning. The implications of this premise are relevant to theory, diagnosis, and treatment of stress and anxiety-related disorders (e.g., panic disorder, phobias, test anxiety, occupational strain, and related psychosomatic disorders), and to basic and applied research in the psychophysiology of breathing.

  5. Take a Deep Breath

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Everyone involved in Beijing’s Olympic Games held their breath last week, not because of the city’s famously polluted air , but in anticipation of the results of an experiment that could help to clean it up.

  6. Minimizing Shortness of Breath

    Science.gov (United States)

    ... is also placed on proper use of the abdominal muscles to better control episodes of shortness of breath, ... Treatment & Programs Health Insights Doctors & Departments Research & Science Education & Training Make a Donation Make an Appointment Contact ...

  7. Breathing difficulty - lying down

    Science.gov (United States)

    ... short of breath. Considerations This is a common complaint in people with some types of heart or ... ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow ...

  8. Investigation of Metabolism of Exogenous Glucose at the Early Stage and Onset of Diabetes Mellitus in Otsuka Long-Evans Tokushima Fatty Rats Using [1, 2, 3-13C]Glucose Breath Tests.

    Science.gov (United States)

    Kawagoe, Naoyuki; Kano, Osamu; Kijima, Sho; Tanaka, Hideki; Takayanagi, Masaaki; Urita, Yoshihisa

    2016-01-01

    This study aimed to evaluate changes in glucose metabolism at the early stage and onset of diabetes in Otsuka Long-Evans Tokushima Fatty (OLETF) rats. Specifically, after the oral administration of [1, 2, 3-13C]glucose, the levels of exhaled 13CO2, which most likely originated from pyruvate decarboxylation and tricarboxylic acid, were measured. Eight OLETF rats and eight control rats (Long-Evans Tokushima Otsuka [LETO]) were administered 13C-glucose. Three types of 13C-glucose breath tests were performed thrice in each period at 2-week intervals. [3-13C]glucose results in a 13C isotope at position 1 in the pyruvate molecule, which provides 13CO2. The 13C at carbons 1 and 2 of glucose is converted to 13C at carbons 2 and 1 of acetate, respectively, which produce 13CO2. Based on metabolic differences of the labeled sites, glucose metabolism was evaluated using the results of three breath tests. The increase in 13CO2 excretion in OLETF rats was delayed in all three breath tests compared to that in control rats, suggesting that OLETF rats had a lower glucose metabolism than control rats. In addition, overall glucose metabolism increased with age in both groups. The utilization of [2-13C]glucose was suppressed in OLETF rats at 6-12 weeks of age, but they showed higher [3-13C]glucose oxidation than control rats at 22-25 weeks of age. In the [1-13C]glucose breath test, no significant differences in the area under the curve until 180 minutes (AUC180) were observed between OLETF and LETO rats of any age. Glucose metabolism kinetics were different between the age groups and two groups of rats; however, these differences were not significant based on the overall AUC180 of [1-13C]glucose. We conclude that breath 13CO2 excretion is reduced in OLETF rats at the primary stage of prediabetes, indicating differences in glucose oxidation kinetics between OLETF and LETO rats.

  9. Automatic Recognition of Breathing Route During Sleep Using Snoring Sounds

    Science.gov (United States)

    Mikami, Tsuyoshi; Kojima, Yohichiro

    This letter classifies snoring sounds into three breathing routes (oral, nasal, and oronasal) with discriminant analysis of the power spectra and k-nearest neighbor method. It is necessary to recognize breathing route during snoring, because oral snoring is a typical symptom of sleep apnea but we cannot know our own breathing and snoring condition during sleep. As a result, about 98.8% classification rate is obtained by using leave-one-out test for performance evaluation.

  10. Effect of slow deep breathing (6 breaths/min) on pulmonary function in healthy volunteers

    OpenAIRE

    Shravya Keerthi G, Hari Krishna Bandi, Suresh M, Mallikarjuna Reddy

    2013-01-01

    We designed this study to test the hypothesis that whether 10 minutes of slow deep breathing have any effect on pulmonary function in healthy volunteers. The main objective was to study the immediate effect of slow deep breathing on Forced vital capacity (FVC), Forced expiratory volume in the first second (FEV1), Forced expiratory volume percent (FEV1/FVC%), Peak expiratory flow rate (PEFR), Forced expiratory flow 25-75%(FEF25-75%), Maximum voluntary ventilation (MVV), Slow vital capacity (SV...

  11. A simple optical fiber interferometer based breathing sensor

    Science.gov (United States)

    Li, Xixi; Liu, Dejun; Kumar, Rahul; Ng, Wai Pang; Fu, Yong-qing; Yuan, Jinhui; Yu, Chongxiu; Wu, Yufeng; Zhou, Guorui; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang

    2017-03-01

    A breathing sensor has been experimentally demonstrated based on a singlemode–multimode–singlemode (SMS) fiber structure which is attached to a thin plastic film in an oxygen mask. By detecting power variations due to the macro bending applied to the SMS section by each inhalation and exhalation process, the breath state can be monitored. The proposed sensor is capable of distinguishing different types of breathing conditions including regular and irregular breath state. The sensor can be used in a strong electric/magnetic field and radioactive testing systems such as magnetic resonance imaging (MRI) systems and computed tomography (CT) examinations where electrical sensors are restricted.

  12. Breathing exercises for dysfunctional breathing/hyperventilation syndrome in adults

    OpenAIRE

    2013-01-01

    Copyright © 2013 The Cochrane Collaboration. Published by JohnWiley & Sons, Ltd. Background: Dysfunctional breathing/hyperventilation syndrome (DB/HVS) is a respiratory disorder, psychologically or physiologically based, involving breathing too deeply and/or too rapidly (hyperventilation) or erratic breathing interspersed with breath-holding or sighing (DB). DB/HVS can result in significant patient morbidity and an array of symptoms including breathlessness, chest tightness, dizziness, tre...

  13. Lung cancer biomarkers in exhaled breath.

    Science.gov (United States)

    Amann, Anton; Corradi, Massimo; Mazzone, Peter; Mutti, Antonio

    2011-03-01

    Lung cancer is the leading cause of cancer-related mortality worldwide. Methods for early detection of lung cancer, such as computerized tomography scanning technology, often discover a large number of small lung nodules, posing a new problem to radiologists and chest physicians. The vast majority of these nodules will be benign, but there is currently no easy way to determine which nodules represent very early lung cancer. Adjuvant testing with PET imaging and nonsurgical biopsies has a low yield for these small indeterminate nodules, carries potential morbidity and is costly. Indeed, purely morphological criteria seem to be insufficient for distinguishing lung cancer from benign nodules at early stages with sufficient confidence, therefore false positives undergoing surgical resection frequently occur. A molecular approach to the diagnosis of lung cancer through the analysis of exhaled breath could greatly improve the specificity of imaging procedures. A biomarker-driven approach to signs or symptoms possibly due to lung cancer would represent a complementary tool aimed at ruling out (with known error probability) rather than diagnosing lung cancer. Volatile and nonvolatile components of the breath are being studied as biomarkers of lung cancer. Breath testing is noninvasive and potentially inexpensive. There is promise that an accurate lung cancer breath biomarker, capable of being applied clinically, will be developed in the near future. In this article, we summarize some of the rationale for breath biomarker development, review the published literature in this field and provide thoughts regarding future directions.

  14. Breath hydrogen analysis in patients with ileoanal pouch anastomosis

    DEFF Research Database (Denmark)

    Bruun, E; Meyer, J N; Rumessen, J J;

    1995-01-01

    The possible influence on functional outcomes of hydrogen production in the ileoanal pouch after restorative proctocolectomy was investigated by means of lactulose H2 breath tests. Eight of 15 patients had significant increases in breath hydrogen after 10 g lactulose. One patient declined to part...

  15. The Air We Breathe

    Science.gov (United States)

    Davila, Dina

    2010-01-01

    Topics discussed include NASA mission to pioneer the future in space exploration, scientific discovery and aeronautics research; the role of Earth's atmosphere, atmospheric gases, layers of the Earth's atmosphere, ozone layer, air pollution, effects of air pollution on people, the Greenhouse Effect, and breathing on the International Space Station.

  16. The Breath of Chemistry

    DEFF Research Database (Denmark)

    Josephsen, Jens

    The present preliminary text is a short thematic presentation in biological inorganic chemistry meant to illustrate general and inorganic (especially coordination) chemistry in biochemistry. The emphasis is on molecular models to explain features of the complicated mechanisms essential to breathing...

  17. Breathing Like a Fish

    Science.gov (United States)

    Katsioloudis, Petros J.

    2010-01-01

    Being able to dive and breathe underwater has been a challenge for thousands of years. In 1980, Fuji Systems of Tokyo developed a series of prototype gills for divers as a way of demonstrating just how good its membranes are. Even though gill technology has not yet reached the point where recipients can efficiently use implants to dive underwater,…

  18. Breath biomarkers and non-alcoholic fatty liver disease: preliminary observations.

    Science.gov (United States)

    Solga, S F; Alkhuraishe, A; Cope, K; Tabesh, A; Clark, J M; Torbenson, M; Schwartz, P; Magnuson, T; Diehl, A M; Risby, T H

    2006-01-01

    Breath biomarkers have the potential to offer information that is similar to conventional clinical tests or they are entirely unique. Preliminary data support the use of breath biomarkers in the study of liver disease, in particular non-alcoholic fatty liver disease (NAFLD). It was evaluated whether breath ethanol, ethane, sulfur compounds and acetone would be associated with hepatic histopathology amongst morbidly obese patients presenting for bariatric surgery. Breath samples were collected during a preoperative visit and compared with liver biopsies obtained during the surgery. A Student's two-tailed t-test was used to compare differences between the two groups. Linear regression was used to analyse associations between the concentrations of breath molecules and independent predictor variables. It was found that breath ethanol, ethane and acetone can be useful biomarkers in patients with NAFLD. In particular, breath ethanol can be associated with hepatic steatosis, and breath acetone can be associated with non-alcoholic steatohepatitis.

  19. Breathing Better with a COPD Diagnosis

    Science.gov (United States)

    Now that you kNow it’s CoPD, here’s how to breathe better. You have taken the important step of being aware of your symptoms, and seeing your doctor ... care provider for testing and a diagnosis. While COPD (Chronic Obstructive Pulmonary Disease) is a serious lung ...

  20. Upper limb kinematic differences between breathing and non-breathing conditions in front crawl sprint swimming.

    Science.gov (United States)

    McCabe, Carla B; Sanders, Ross H; Psycharakis, Stelios G

    2015-11-26

    The purpose of this study was to determine whether the breathing action in front crawl (FC) sprint swimming affects the ipsilateral upper limb kinematics relative to a non-breathing stroke cycle (SC). Ten male competitive swimmers performed two 25m FC sprints: one breathing to their preferred side (Br) and one not breathing (NBr). Both swim trials were performed through a 6.75m(3) calibrated space and recorded by six gen-locked JVC KY32 CCD cameras. A paired t-test was used to assess statistical differences between the trials, with a confidence level of pswim performance is compromised by the inclusion of taking a breath in sprint FC swimming. It was proposed that swimmers aim to orient their ipsilateral shoulder into a stronger position by stretching and rolling the shoulders more in the entry phase whilst preparing to take a breath. Swimmers should focus on lengthening the push phase by extending the elbow more and not accelerating the hand too quickly upwards when preparing to inhale.

  1. [Prevalence of mouth breathing in children from an elementary school].

    Science.gov (United States)

    Felcar, Josiane Marques; Bueno, Izabele Rafael; Massan, Ana Carolina Silva; Torezan, Roberta Pereira; Cardoso, Jefferson Rosa

    2010-03-01

    The objective of this article is to identify the prevalence of mouth breathing in children from an elementary school. 496 questionnaires were answered by 1st and 4th grade children's parents or sponsors in order to identify mouth-breathing. There were questions about habits, sleeping, behavior, eating, personal care and breathing. Mann-Whitney and the Chi-square tests were used to compare the variables between mouth-breathing and nose-breathing among the groups. To measure the exposure effect of the explanatory variables on mouth breathing, the test of logistic regression was used and its magnitude was calculated through Odds Ratio. The statistical significance was set at 5%, and the rate of returned questionnaires was 84.5%. The prevalence of the mouthbreathing over this population was 56.8%. The average age was 7 years old (6-9). There was no significant statistical difference between genders, considering 49.1% male and 50.9% female. The final model of logistic regression identified the variables dribble, sleeps well (negative association) and snores as factors that predict the occurrence of the mouth-breathing. The prevalence of mouthbreathing was similar to related in the literature. The variables dribble, sleeps well (negative association) and snores may be factors that predict the occurrence of mouth-breathing.

  2. Breath Figures Formation

    OpenAIRE

    Guadarrama-Cetina, J.; González-Viñas, W

    2013-01-01

    We present experimental observations of Breath Figures (BF) which are formed by the dew of water when it condenses on a cold surface. The experiments were done in specific conditions and configurations of temperature, surfaces and mixes in controlled concentration of miscibles and immiscibles substances like the salt saturated solution, alcohol and silicon oil (C_6H_18O_2Si). The hydrophobic surfaces used on those observations are thin glasses coated with ITO (Indium Tin Oxide), 3M ECG-1700 w...

  3. Learn More Breathe Better

    Centers for Disease Control (CDC) Podcasts

    2011-11-16

    Chronic obstructive pulmonary disease (COPD) is a serious lung disease that makes breathing very difficult and can affect your quality of life. Learn the causes of COPD and what you can do to prevent it.  Created: 11/16/2011 by National Center for Chronic Disease Prevention and Health Promotion, Division of Adult and Community Health (NCCDPHP, DACH).   Date Released: 11/16/2011.

  4. A fully integrated standalone portable cavity ringdown breath acetone analyzer

    Science.gov (United States)

    Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji

    2015-09-01

    Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.

  5. Effect of dietary fiber on carbohydrate absorption in humans with 13C-breath test%13C呼气试验评价膳食纤维对人体碳水化合物吸收的影响

    Institute of Scientific and Technical Information of China (English)

    江旻; 王洪允; 李宁; 胡蓓; 江骥

    2012-01-01

    目的 采用13C呼气试验和血糖测定的方法评价非水溶性膳食纤维对健康成年人碳水化合物吸收的影响,比较其敏感度.方法 入选10例中国健康成年受试者,随机分成2组.采用开放、双周期、交叉试验设计,在每个试验周期,受试者分别服用无膳食纤维或高膳食纤维试验餐,采集空腹和餐后系列时间点血样和呼气样本,测定血糖和13CO2丰度.两个周期间隔1d的清洗期.结果 高膳食纤维组的餐后血糖峰值低于无膳食纤维组,达峰时间延迟,但差异无统计学意义(P>0.05);餐后0~3 h血糖曲线下面积在两组间差异无统计学意义(P>0.05);13C呼气试验结果与血糖代谢动态变化趋势一致,但13C丰度变化曲线清晰显示膳食纤维对人体对碳水化合物吸收的作用(高纤维膳食组650.35 delta.min,无纤维膳食组723.31 delta.min).结论 与血糖测定相比,13C呼气试验能够更加灵敏地反映膳食纤维对人体碳水化合物吸收的影响.%Objective To investigate the effect of non-soluble dietary fiber on the absorption of carbohydrate with 13C-breath test and serum glucose, and compare the sensitivity of the two methods. Methods In this open-label, two-period and crossover study, 10 healthy Chinese adult volunteers were enrolled and randomized into 2 groups. On each study period, the subjects received fiber-free or high-fiber test meals. Serial blood and breath samples were collected pre- and post-meal. Serum glucose and 13C abundances were measured. Results Compared with the dietary fiber free group, the peak values of postprandial serum glucose was slightly lower in the high dietary fiber group and the peak time was delayed, but there was no statistical significance (P > 0.05); area under curve 0~3 h in the two groups was not statistically different (P > 0.05). Metabolic kinetics observed in the 13C-breath test was similar to that of the serum glucose, but the effect of dietary fiber on

  6. Influence of condensation temperature on selected exhaled breath parameters

    Directory of Open Access Journals (Sweden)

    Manini Paola

    2005-09-01

    Full Text Available Abstract Background The effects of changes in cooling temperature on biomarker levels in exhaled breath condensate have been little investigated. The aim of the study was to test the effect of condensation temperature on the parameters of exhaled breath condensate and the levels of selected biomarkers. Methods Exhaled breath condensate was collected from 24 healthy subjects at temperatures of -10, -5, 0 and +5 C degrees. Selected parameters (condensed volume and conductivity and biomarkers (hydrogen peroxide, malondialdehyde were measured. Results There was a progressive increase in hydrogen peroxide and malondialdehyde concentrations, and condensate conductivity as the cooling temperature increased; total condensate volume increased as the cooling temperature decreased. Conclusion The cooling temperature of exhaled breath condensate collection influenced selected biomarkers and potential normalizing factors (particularly conductivity in different ways ex vivo. The temperature of exhaled breath condensate collection should be controlled and reported.

  7. Diagnostic accuracy of a rapid fecal test to confirm H pylori eradication after therapy: Prospective comparison with a laboratory stool test

    Institute of Scientific and Technical Information of China (English)

    Lucio Trevisani; Viviana Cifalà; Nadia Fusetti; Giuseppe Gilli; Paola Tombesi; Marco Torchiaro; Sergio Boccia; Vincenzo Abbasciano

    2007-01-01

    AIM: To investigate the clinical performances of rapid stool test (ImmunoCard STAT HpSA, Meridian Diagnostic Inc.) in the evaluation of eradication therapy of H pylori and to compare it with a well-known and validated laboratory stool test (Amplified IDEA Hp StAR, Dako).METHODS: Stool samples of 122 patients were evaluated after eradication therapy of H pylori. H pyloristatus was assessed by 13C-urea breath test (UBT).Stool specimens were tested using either the rapid immunoassay kit or the laboratory immunoassay kit.RESULTS: Forty-three patients were infected and 79 non-infected. Sensitivity and specificity of ImmunoCard STAT and Hp StAR were 58.14% and 76.4%, and 97.47% and 98.73%, respectively (P > 0.05). Overall agreement between the two tests was 92.6% (113 of 122 cases).CONCLUSION: ImmunoCard STAT seems to have rather low performances, and it cannot be regarded as a reliable tool in the post-treatment setting. Also Hp StAR cannot be recommended to confirm H pylori eradication after treatment.

  8. Breathing pattern, thoracoabdominal motion and muscular activity during three breathing exercises

    Directory of Open Access Journals (Sweden)

    G.M. Tomich

    2007-10-01

    Full Text Available The objective of the present study was to evaluate breathing pattern, thoracoabdominal motion and muscular activity during three breathing exercises: diaphragmatic breathing (DB, flow-oriented (Triflo II incentive spirometry and volume-oriented (Voldyne incentive spirometry. Seventeen healthy subjects (12 females, 5 males aged 23 ± 5 years (mean ± SD were studied. Calibrated respiratory inductive plethysmography was used to measure the following variables during rest (baseline and breathing exercises: tidal volume (Vt, respiratory frequency (f, rib cage contribution to Vt (RC/Vt, inspiratory duty cycle (Ti/Ttot, and phase angle (PhAng. Sternocleidomastoid muscle activity was assessed by surface electromyography. Statistical analysis was performed by ANOVA and Tukey or Friedman and Wilcoxon tests, with the level of significance set at P < 0.05. Comparisons between baseline and breathing exercise periods showed a significant increase of Vt and PhAng during all exercises, a significant decrease of f during DB and Voldyne, a significant increase of Ti/Ttot during Voldyne, and no significant difference in RC/Vt. Comparisons among exercises revealed higher f and sternocleidomastoid activity during Triflo II (P < 0.05 with respect to DB and Voldyne, without a significant difference in Vt, Ti/Ttot, PhAng, or RC/Vt. Exercises changed the breathing pattern and increased PhAng, a variable of thoracoabdominal asynchrony, compared to baseline. The only difference between DB and Voldyne was a significant increase of Ti/Ttot compared to baseline. Triflo II was associated with higher f values and electromyographic activity of the sternocleidomastoid. In conclusion, DB and Voldyne showed similar results while Triflo II showed disadvantages compared to the other breathing exercises.

  9. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Compressed breathing gas and liquefied breathing... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing gas and liquefied breathing gas containers; minimum requirements. (a) Compressed breathing gas...

  10. Structure Form and Testing of Mine Breathing and Discharge Fluid Ex component%矿用呼吸和排液Ex元件结构形式与试验

    Institute of Scientific and Technical Information of China (English)

    周伟锋

    2012-01-01

    Combined with the requirements of GB3836.2 -2010, explosion - proof flame arrester principle, structure form, materials used and installation means of mine breathing and discharge fuluid Ex components are introduced. Requirements and methods of flam- proof enclosure type test of its pressure capacity test, thermal test, not - transmission explosion test of interna lignition and other tests are analyzed. At the same time, a few notes in the process of designing, applying and testing process are discussed.%结合GB3836.2—2010的要求,对矿用呼吸和排液Ex元件的防爆阻火原理、结构形式、使用材料与安装方式进行了介绍,对其的承受压力能力试验、热试验、内部点燃不传爆试验等防爆型式试验的要求与方法进行了分析,同时对设计、使用、试验过程中的几个注意事项进行了探讨。

  11. Fast-starting for a breath: Air breathing in Hoplosternum littorale

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2012-01-01

    overlap considerably in their kinematics (turning rates and distance covered), suggesting that air breathing in this species is performed using escapelike C-start motions. This demonstrates that C-starts in fish do not need external stimulation and can be spontaneous behaviours used outside the context...... to be food-related. Little is known about C-starts being used outside the context of escaping or feeding. Here, we test the hypothesis that air-breathing fish may use C-starts when gulping air at the surface. Air breathing is a common behaviour in many fish species when exposed to hypoxia, although certain...... of Denmark, Denmark), John F. Steffensen (University of Copenhagen, Denmark), Morten Svendsen (Technical University of Denmark, Denmark) and Augusto Abe (Unlversidade Estadual Paulista, Brazil) Fast starts are brief accelerations commonly observed in fish within the context of predator-prey interactions...

  12. Tongue Scrapers Only Slightly Reduce Bad Breath

    Science.gov (United States)

    ... your desktop! more... Tongue Scrapers Only Slightly Reduce Bad Breath Article Chapters Tongue Scrapers Only Slightly Reduce ... oral cavity. Reviewed: January 2012 Related Articles: Halitosis (Bad Breath) Do You Have Traveler's Breath? Does a ...

  13. Teste respiratório da 13C-metacetina na doença hepática crônica pelo vírus C 13C-methacetin breath test in hepatitis C chronic liver disease

    Directory of Open Access Journals (Sweden)

    Ana Cláudia Oliveira

    2006-03-01

    óticos (19,2 ± 7,1% para cirróticos compensados e 14,7 ± 4,0% para os cirróticos descompensados que nos grupos controle (29,9 ± 4,5% e com hepatite crônica (27,8 ± 6,1%. A melhor acurácia no diagnóstico de cirrose entre os portadores de hepatite crônica C foi encontrada para o teste respiratório da 13C-metacetina 120 min com 81% de sensibilidade e 77% de especificidade. CONCLUSÃO: O teste respiratório da 13C-metacetina se correlaciona com alterações estruturais encontradas na hepatite crônica pelo vírus C e o percentual de recuperação de 13CO2 aos 120 minutos é um sensível parâmetro para identificar a presença de cirrose nesses pacientes.BACKGROUND: The 13C-methacetin breath test is a non-invasive method to evaluate hepatic microssomal function that allows a quantitative assessment of the functional hepatic mass. AIM: To evaluate the clinical usefulness of the 13C-methacetin breath test in patients with hepatitis C chronic liver disease. PATIENTS AND METHODS: Seventy eight patients with chronic hepatitis C and 13 matched healthy controls were studied. HCV patients were classified as having chronic hepatitis (n = 51, cirrhosis (n = 27, being seven with decompensated disease (presence of ascite, jaundice and/or encephalopathy. HbsAg/HIV co-infected patients, chronic alcohol drinker, having other chronic diseases and those using drugs that could interfere with hepatic cytochrome P450, were excluded. The disease stage and activity in biopsy fragments were determined according the Brazilian Society of Hepatology criteria. Breath test was performed with 75 mg of 13C-methacetin, and the 13CO2 in the expired air was measured through a nondispersive infra red spectrometry. The delta over baseline, and the cumulative recovery of 13CO2 at 40 (13C-methacetin breath test 40 min and 120 minutes (13C-methacetin breath test 120 min were calculated. RESULTS: 13C-methacetin breath test parameters correlate only with hepatic staging but not with necroinflammatory

  14. Breath in the technoscientific imaginary.

    Science.gov (United States)

    Rose, Arthur

    2016-12-01

    Breath has a realist function in most artistic media. It serves to remind the reader, the viewer or the spectator of the exigencies of the body. In science fiction (SF) literature and films, breath is often a plot device for human encounters with otherness, either with alien peoples, who may not breathe oxygen, or environments, where there may not be oxygen to breathe. But while there is a technoscientific quality to breath in SF, especially in its attention to physiological systems, concentrating on the technoscientific threatens to occlude other, more affective aspects raised by the literature. In order to supplement the tendency to read SF as a succession of technoscientific accounts of bodily experience, this paper recalls how SF texts draw attention to the affective, non-scientific qualities of breath, both as a metonym for life and as a metaphor for anticipation. Through an engagement with diverse examples from SF literature and films, this article considers the tension between technoscientific and affective responses to breath in order to demonstrate breath's co-determinacy in SF's blending of scientific and artistic discourses.

  15. BREATHE to Understand©

    Science.gov (United States)

    Swisa, Maxine

    2015-01-01

    BREATHE is an acronym for Breathe, Reflect, Empathize, Accept, Thank, Hearten, Engage. The addition of Understand allows for a holistic approach to living a healthy and balanced life both inside and outside the classroom. This paper took form as a result of my personal, spiritual journey, as well as my teaching practice. I noticed that the…

  16. FMWC Radar for Breath Detection

    DEFF Research Database (Denmark)

    Suhr, Lau Frejstrup; Tafur Monroy, Idelfonso; Vegas Olmos, Juan José

    We report on the experimental demonstration of an FMCW radar operating in the 25.7 - 26.6 GHz range with a repetition rate of 500 sweeps per second. The radar is able to track the breathing rate of an adult human from a distance of 1 meter. The experiments have utilized a 50 second recording window...... to accurately track the breathing rate. The radar utilizes a saw tooth modulation format and a low latency receiver. A breath tracking radar is useful both in medical scenarios, diagnosing disorders such as sleep apnea, and for home use where the user can monitor its health. Breathing is a central part of every...... radar chip which, through the use of a simple modulation scheme, is able to measure the breathing rate of an adult human from a distance. A high frequency output makes sure that the radar cannot penetrate solid obstacles which is a wanted feature in private homes where people therefore cannot measure...

  17. Advances in exhaled breath condensate collection and testing standardization%呼出气冷凝液收集和检测的研究进展

    Institute of Scientific and Technical Information of China (English)

    张宏天; 陈建荣

    2015-01-01

    呼吸道内衬液中含有大量挥发性和非挥发性的物质,这些物质的变化可反映氧化损伤和 炎症反应等呼吸道内环境的变化,从而用于检测疾病的变化.呼出气冷凝液(EBC)是一种检测呼吸道生化成分的最新技术,又称为生化肺功能.因其具有安全、无创、收集简单、可多次重复等优点而受到广泛关注.本文对EBC的组成成分和来源、稀释度及标准化、收集及标准化、测量及标准化、EBC中标志物等研究进展进行综述.%Airway lining fluid contains large amounts of volatile and non-volatile substances.The changes of these substances can reflect changes including inflammation and oxidative damage in the environment of the respiratory tract,so as to detect changes in the disease.Exhaled breath condensate (EBC) is a new technology to detect biochemical components in airway,also known as biochemical lung function.Because of its safe,non-invasive,simple to collect and can be repeated,EBC has draw wide attention.In this paper,EBC's composition and origin,dilution and standardization,collection and standardization,measurement and standardization,biomarkers in EBC were reviewed.

  18. How and When Do Insects Rely on Endogenous Protein and Lipid Resources during Lethal Bouts of Starvation? A New Application for 13C-Breath testing.

    Directory of Open Access Journals (Sweden)

    Marshall D McCue

    Full Text Available Most of our understanding about the physiology of fasting and starvation comes from studies of vertebrates; however, for ethical reasons, studies that monitor vertebrates through the lethal endpoint are scant. Insects are convenient models to characterize the comparative strategies used to cope with starvation because they have diverse life histories and have evolved under the omnipresent challenge of food limitation. Moreover, we can study the physiology of starvation through its natural endpoint. In this study we raised populations of five species of insects (adult grasshoppers, crickets, cockroaches, and larval beetles and moths on diets labeled with either 13C-palmitic acid or 13C-leucine to isotopically enrich the lipids or the proteins in their bodies, respectively. The insects were allowed to become postabsorptive and then starved. We periodically measured the δ13C of the exhaled breath to characterize how each species adjusted their reliance on endogenous lipids and proteins as energy sources. We found that starving insects employ a wide range of strategies for regulating lipid and protein oxidation. All of the insects except for the beetle larvae were capable of sharply reducing reliance on protein oxidation; however, this protein sparing strategy was usually unsustainable during the entire starvation period. All insects increased their reliance on lipid oxidation, but while some species (grasshoppers, cockroaches, and beetle larvae were still relying extensively on lipids at the time of death, other species (crickets and moth larvae allowed rates of lipid oxidation to return to prestarvation levels. Although lipids and proteins are critical metabolic fuels for both vertebrates and insects, insects apparently exhibit a much wider range of strategies for rationing these limited resources during starvation.

  19. How and When Do Insects Rely on Endogenous Protein and Lipid Resources during Lethal Bouts of Starvation? A New Application for 13C-Breath testing.

    Science.gov (United States)

    McCue, Marshall D; Guzman, R Marena; Passement, Celeste A; Davidowitz, Goggy

    2015-01-01

    Most of our understanding about the physiology of fasting and starvation comes from studies of vertebrates; however, for ethical reasons, studies that monitor vertebrates through the lethal endpoint are scant. Insects are convenient models to characterize the comparative strategies used to cope with starvation because they have diverse life histories and have evolved under the omnipresent challenge of food limitation. Moreover, we can study the physiology of starvation through its natural endpoint. In this study we raised populations of five species of insects (adult grasshoppers, crickets, cockroaches, and larval beetles and moths) on diets labeled with either 13C-palmitic acid or 13C-leucine to isotopically enrich the lipids or the proteins in their bodies, respectively. The insects were allowed to become postabsorptive and then starved. We periodically measured the δ13C of the exhaled breath to characterize how each species adjusted their reliance on endogenous lipids and proteins as energy sources. We found that starving insects employ a wide range of strategies for regulating lipid and protein oxidation. All of the insects except for the beetle larvae were capable of sharply reducing reliance on protein oxidation; however, this protein sparing strategy was usually unsustainable during the entire starvation period. All insects increased their reliance on lipid oxidation, but while some species (grasshoppers, cockroaches, and beetle larvae) were still relying extensively on lipids at the time of death, other species (crickets and moth larvae) allowed rates of lipid oxidation to return to prestarvation levels. Although lipids and proteins are critical metabolic fuels for both vertebrates and insects, insects apparently exhibit a much wider range of strategies for rationing these limited resources during starvation.

  20. Ethylene and ammonia traces measurements from the patients' breath with renal failure via LPAS method

    Science.gov (United States)

    Popa, C.; Dutu, D. C. A.; Cernat, R.; Matei, C.; Bratu, A. M.; Banita, S.; Dumitras, D. C.

    2011-11-01

    The application of laser photoacoustic spectroscopy (LPAS) for fast and precise measurements of breath biomarkers has opened up new promises for monitoring and diagnostics in recent years, especially because breath test is a non-invasive method, safe, rapid and acceptable to patients. Our study involved assessment of breath ethylene and breath ammonia levels in patients with renal failure receiving haemodialysis (HD) treatment. Breath samples from healthy subjects and from patients with renal failure were collected using chemically inert aluminized bags and were subsequently analyzed using the LPAS technique. We have found out that the composition of exhaled breath in patients with renal failure contains not only ethylene, but also ammonia and gives valuable information for determining efficacy and endpoint of HD. Analysis of ethylene and ammonia traces from the human breath may provide insight into severity of oxidative stress and metabolic disturbances and may ensure optimal therapy and prevention of pathology at patients on continuous HD.

  1. Visualizing Breath using Digital Holography

    Science.gov (United States)

    Hobson, P. R.; Reid, I. D.; Wilton, J. B.

    2013-02-01

    Artist Jayne Wilton and physicists Peter Hobson and Ivan Reid of Brunel University are collaborating at Brunel University on a project which aims to use a range of techniques to make visible the normally invisible dynamics of the breath and the verbal and non-verbal communication it facilitates. The breath is a source of a wide range of chemical, auditory and physical exchanges with the direct environment. Digital Holography is being investigated to enable a visually stimulating articulation of the physical trajectory of the breath as it leaves the mouth. Initial findings of this research are presented. Real time digital hologram replay allows the audience to move through holographs of breath-born particles.

  2. Study on parameters of L-[1-13C]phenylalanine breath test for quantitative assessment of liver function in healthy subjects and patients with hepatitis B virus-related liver disease

    Institute of Scientific and Technical Information of China (English)

    YAN Wei-Li; LIN Xiang-Tong; JIANG Yi-Bin; SUN Su; SUN Da-Yu

    2005-01-01

    The aims of this study are to investigate the feasibility and validity of the L-[1-13C] phenylalanine breath test (13C-PheBT) which has been used to measure hepatocyte functional capacity in hepatitis B virus-related liver disease patients and to propose validity parameters of the test in 12 healthy volunteer, 8 chronic hepatitis and 26 liver cirrhotic patients. 100mg/body nonradiative L-[1-13C] phenylalanine (13C-Phe) was administered orally to all subjects.Breath samples were taken before and different intervals within 360 min after administration. The 13CO2/12CO2 enrichment was assessed by isotope ratio mass spectrometer. The parameter percentage 13C excretion rate 13CER, (%13C dose/h) all peaked within 10-30 min after oral 13C-Phe application. The parameters such as maximum value of 13C excretion rate, 13CERmax (% 13C dose/h) (controls: 18.0±3.3; Child A: 11.0±3.8; Child B: 5.0±0.5; Child C:3.6±1.2), 13C excretion rate at 30min, 13CER30 (% dose/h) (controls: 11.9±2.1; Child A: 8.1±0.4; Child B: 6.1±0.9;Child C: 3.2±1.2), 13C cumulative excretion of first 60 min, 13Ccum60 (% 13C dose) (controls: 9.3±1.4; Child A: 6.6±0.7;Child B: 4.1±0.3; Child C: 2.6±0.9) and half time of 13C excretion rate, T1/2 (minutes) (controls: 40.4±4.4; chronic hepatitis: 53.4±4.4; Child A: 59.8±4.5;Child B: 102.0±17.3;Child C: 212.1±87.9) were effective indexes which could be employed to stage hepatocyte impairment and liver functional reserve of advanced HBV-related cirrhotic patients (i.e. healthy subjects, Child A, B, C);T1/2 was also useful for distinguishing mild HBV-related liver injure.

  3. Breath alcohol, multisensor arrays, and electronic noses

    Science.gov (United States)

    Paulsson, Nils; Winquist, Fredrik

    1997-01-01

    The concept behind a volatile compound mapper, or electronic nose, is to use the combination of multiple gas sensors and pattern recognition techniques to detect and quantify substances in gas mixtures. There are several different kinds of sensors which have been developed during recent years of which the base techniques are conducting polymers, piezo electrical crystals and solid state devices. In this work we have used a combination of gas sensitive field effect devices and semiconducting metal oxides. The most useful pattern recognition routine was found to be ANNs, which is a mathematical approximation of the human neural network. The aim of this work is to evaluate the possibility of using electronic noses in field instruments to detect drugs, arson residues, explosives etc. As a test application we have chosen breath alcohol measurements. There are several reasons for this. Breath samples are a quite complex mixture contains between 200 and 300 substances at trace levels. The alcohol level is low but still possible to handle. There are needs for replacing large and heavy mobile instruments with smaller devices. Current instrumentation is rather sensitive to interfering substances. The work so far has dealt with sampling, how to introduce ethanol and other substances in the breath, correlation measurements between the electronic nose and headspace GC, and how to evaluate the sensor signals.

  4. 毛细支气管炎患儿单次潮气肺功能测定的临床意义%Clinical significance of single tidal breathing testing in bronchiolitis

    Institute of Scientific and Technical Information of China (English)

    李睿; 王吉安; 许家增; 杨慧敏

    2014-01-01

    目的:探讨毛细支气管炎患儿测定单次潮气肺功能的临床意义。方法检测和比较住院且<1岁的756例初次喘息毛细支气管炎患儿和115例支气管肺炎患儿的单次潮气肺功能。部分达峰时间比≤第20百分位和≥第80百分位的毛细支气管炎患儿出院1年后电话随访其喘息情况。结果毛细支气管炎患儿与支气管肺炎患儿比较,达峰时间比,达峰容积比,吸气时间,吸呼比,呼出25%、50%潮气容积时的呼气流速的差异有统计学意义(P均<0.05)。达峰时间比≤第20百分位的毛细支气管炎患儿1年内再喘息的比例为37.5%;达峰时间比≥第80百分位的毛细支气管炎患儿1年内再喘息比例为11.3%,两组差异有统计学意义(P<0.05)。结论单次潮气肺功能测定提示,阻塞程度较重的毛细支气管炎患儿再次喘息的可能性较大。%Objective To study clinical signiifcance of single tidal breathing testing in bronchiolitis. Methods Infants with bronchiolitis at ifrst wheezing (bronchiolitis group, n=756), and 115 infants with bronchopneumonia (bronchopneumonia group) hospitalized were enrolled. Tidal breathing parameters were analyzed in two groups. Bronchiolitis group was divided according to percentiles of the fraction of exhaled time at peak tidal expiratory lfow to total expiratory time (TPTEF/TE). The episodes of recurrent wheezing of infants below the 20th or above the 80th percentile of TPTEF/TE were followed up by phone calls within 1 year after discharge from the hospital. Results There were signiifcant differences in TPTEF/TE, VPEF/VE, Ti, Ti/Te, TEF75 and TEF50 between bronchiolitis group and bronchopneumonia group. The recurrent wheezing rate of infants with bronchiolitis below the 20th percentile of TPTEF/TE was signiifcantly higher than that above the 80th percentile of TPTEF/TE (37.5%vs 11.3%). Conclusions There is the greater possibility of recurrent wheezing in the infants with the

  5. Increased oxygen load in the prefrontal cortex from mouth breathing: a vector-based near-infrared spectroscopy study.

    Science.gov (United States)

    Sano, Masahiro; Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori

    2013-12-01

    Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (PMouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient's habitual breathing route than a patient interview.

  6. Standardization of exhaled breath condensate (EBC) collection using a feedback regulated breathing pattern

    Science.gov (United States)

    Collection of exhaled breath condensate (EBC) fluid by cooling of expired breath is a potentially valuable approach for the detection of biomarkers associated with disease or exposure to xenobiotics. EBC is generally collected using unregulated breathing patterns, perceived to el...

  7. Experiments on the Microenvironment and Breathing of a Person in Isothermal and Stratified Surroundings

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Litewnicki, Michal;

    2009-01-01

    This study investigates the characteristics of human exhalation. Experiments are performed on a breathing thermal manikin in a test room. The manikin is heated, and an artificial lung is used to generate varying air flows with specific flow rates and temperatures for breathing. Smoke visualisation...... is used to show the formation, movement and disappearance of the exhalation jets from both nose and mouth. The exhalation of breathing without ventilation in the room, and with stratified surroundings (displacement ventilation) is analysed....

  8. Effects of diaphragm breathing exercise and feedback breathing exercise on pulmonary function in healthy adults

    OpenAIRE

    Yong, Min-Sik; Lee, Hae-Yong; Lee, Yun-Seob

    2017-01-01

    [Purpose] The present study investigated effects of diaphragm breathing exercise and feedback breathing exercise on respiratory function. [Subjects and Methods] Thirty-one subjects were randomly assigned to two groups; the feedback breathing exercise group and the maneuver-diaphragm exercise group. The feedback breathing exercise group was asked to breathe with feedback breathing device, and the maneuver-diaphragm exercise group was asked to perform diaphragm respiration. Respiratory function...

  9. An Experimental Study of Human Exhalation during Breathing and Coughing in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Liu, Li; Lia, Yuguo; Nielsen, Peter V.;

    2009-01-01

    This study investigates the characteristics of human exhalation during breathing and coughing. Experiments employing one breathing thermal manikin are conducted in a full-scale test room with a mixing ventilation system. Two artificial lungs are used to generate discontinuous airflows with specific...... flow rates and temperatures for breathing and coughing, respectively. Smoke visualizations are conducted to show the formation, movement and vanishing of the exhalation jets from nose and mouth separately. The transient velocity distribution generated by breathing and coughing in different places...

  10. System of Optoelectronic Sensors for Breath Analysis

    Directory of Open Access Journals (Sweden)

    Mikołajczyk Janusz

    2016-09-01

    Full Text Available The paper describes an integrated laser absorption system as a potential tool for breath analysis for clinical diagnostics, online therapy monitoring and metabolic disorder control. The sensors operate basing on cavity enhanced spectroscopy and multi-pass spectroscopy supported by wavelength modulation spectroscopy. The aspects concerning selection of operational spectral range and minimization of interference are also discussed. Tests results of the constructed devices collected with reference samples of biomarkers are also presented. The obtained data provide an opportunity to analyse applicability of optoelectronic sensors in medical screening.

  11. Respiratory pattern of diaphragmatic breathing and pilates breathing in COPD subjects

    Directory of Open Access Journals (Sweden)

    Karina M. Cancelliero-Gaiad

    2014-08-01

    Full Text Available BACKGROUND: Diaphragmatic breathing (DB is widely used in pulmonary rehabilitation (PR of patients with chronic obstructive pulmonary disease (COPD, however it has been little studied in the scientific literature. The Pilates breathing (PB method has also been used in the rehabilitation area and has been little studied in the scientific literature and in COPD. OBJECTIVES: To compare ventilatory parameters during DB and PB in COPD patients and healthy adults. METHOD: Fifteen COPD patients (COPD group and fifteen healthy patients (healthy group performed three types of respiration: natural breathing (NB, DB, and PB, with the respiratory pattern being analyzed by respiratory inductive plethysmography. The parameters of time, volume, and thoracoabdominal coordination were evaluated. After the Shapiro-Wilk normality test, ANOVA was applied followed by Tukey's test (intragroup analysis and Student's t-test (intergroup analysis; p<0.05. RESULTS: DB promoted increase in respiratory volumes, times, and SpO2 as well as decrease in respiratory rate in both groups. PB increased respiratory volumes in healthy group, with no additional benefits of respiratory pattern in the COPD group. With respect to thoracoabdominal coordination, both groups presented higher asynchrony during DB, with a greater increase in the healthy group. CONCLUSIONS: DB showed positive effects such as increase in lung volumes, respiratory motion, and SpO2 and reduction in respiratory rate. Although there were no changes in volume and time measurements during PB in COPD, this breathing pattern increased volumes in the healthy subjects and increased oxygenation in both groups. In this context, the acute benefits of DB are emphasized as a supporting treatment in respiratory rehabilitation programs.

  12. Taking a deep breath

    Directory of Open Access Journals (Sweden)

    Carlos Renato Zacharias

    2012-12-01

    be paid to language revision and reference citation. Together with its authors and readers, IJHDR contributes to the development of a kind of knowledge close to the borders of science. Therefore, to establish a valid scientific background, the articles must be clearly written, and based on sound assumptions. High-visibility for articles is a fundamental aspect desired by all authors. As an open and free access journal, IJHDR meets that condition, and we are planning to make our influence and visibility even wider. Inclusion in the major databases has paramount importance in the academic milieu, however, it should be considered as a consequence, rather than a goal. In 2013, IJHDR will chair a collaborative project with several research institutions aiming to deliver information everywhere, increasing the visibility of the published articles. Thus, now it is the time to take a deep breath, relax, and prepare you for the forthcoming work! See you in 2013!

  13. Diagnostic accuracy of tests for Helicobacter pylori in an Alaska Native population

    Institute of Scientific and Technical Information of China (English)

    Dana L Bruden; Brian J McMahon; Michael G Bruce; Karen M Miernyk; Julie Morris; Debby Hurlburt; Thomas W Hennessy; Helen Peters; Frank Sacco; Alan J Parkinson

    2011-01-01

    AIM: To evaluate the accuracy of two non-invasive tests in a population of Alaska Native persons. High rates of Helicobacter pylori (H, pylori) infection, H. py iori treatment failure, and gastric cancer in this popula tion necessitate documentation of infection status at multiple time points over a patient's life.METHODS: In 280 patients undergoing endoscopy, H, pylori was diagnosed by culture, histology, rapidurease test, 13C urea breath test (UBT), and immuno globulin G antibodies to H. pylori in serum. The perfor mances of 13C-UBT and antibody test were compared to a gold standard defined by a positive H, pylori test by culture or, in case of a negative culture result, by positive histology and a positive rapid urease test.RESULTS: The sensitivity and specificity of the 13C-UBT were 93% and 88%, respectively, relative to the gold standard. The antibody test had an equivalent sensitivity of 93% with a reduced specificity of 68%. The false positive results for the antibody test were as sociated with previous treatment for an H, pylori infec tion [relative risk (RR) = 2.8]. High levels of antibodies to H. pylori were associated with chronic gastritis and male gender, while high scores in the 13C-UBT test were associated with older age and with the H. pylori bacteria load on histological examination (RR = 4.4).CONCLUSION: The 13C-UBT outperformed the anti body test for H, pylori and could be used when a non invasive test is clinically necessary to document treat ment outcome or when monitoring for reinfection.

  14. An efficient and reproducible method for measuring hydrogen peroxide in exhaled breath condensate.

    NARCIS (Netherlands)

    Beurden, W.J.C van; Harff, G.A.; Dekhuijzen, P.N.R.; Bosch, M.J. van den; Creemers, J.P.H.M.; Smeenk, F.J.M.W.

    2002-01-01

    We investigated the sensitivity and reproducibility of a test procedure for measuring hydrogen peroxide (H202) in exhaled breath condensate and the effect of storage of the condensate on the H2O2 concentration, and compared the results to previous studies.Twenty stable COPD patients breathed into ou

  15. Imposed work of breathing during high-frequency oscillatory ventilation : a bench study

    NARCIS (Netherlands)

    van Heerde, Marc; van Genderingen, Huib R.; Leenhoven, Tom; Roubik, Karel; Ploetz, Frans B.; Markhorst, Dick G.

    2006-01-01

    Introduction The ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequ

  16. Bacterial contamination of anesthesia machines’ internal breathing-circuit-systems

    Science.gov (United States)

    Spertini, Verena; Borsoi, Livia; Berger, Jutta; Blacky, Alexander; Dieb-Elschahawi, Magda; Assadian, Ojan

    2011-01-01

    Background: Bacterial contamination of anesthesia breathing machines and their potential hazard for pulmonary infection and cross-infection among anesthetized patients has been an infection control issue since the 1950s. Disposable equipment and bacterial filters have been introduced to minimize this risk. However, the machines’ internal breathing-circuit-system has been considered to be free of micro-organisms without providing adequate data supporting this view. The aim of the study was to investigate if any micro-organisms can be yielded from used internal machines’ breathing-circuit-system. Based on such results objective reprocessing intervals could be defined. Methods: The internal parts of 40 anesthesia machines’ breathing-circuit-system were investigated. Chi-square test and logistic regression analysis were performed. An on-site process observation of the re-processing sequence was conducted. Results: Bacterial growth was found in 17 of 40 machines (43%). No significant difference was ascertained between the contamination and the processing intervals. The most common contaminants retrieved were coagulase negative Staphylococci, aerobe spore forming bacteria and Micrococcus species. In one breathing-circuit-system, Escherichia coli, and in one further Staphylococcus aureus were yielded. Conclusion: Considering the availability of bacterial filters installed on the outlet of the breathing-circuit-systems, the type of bacteria retrieved and the on-site process observation, we conclude that the contamination found is best explained by a lack of adherence to hygienic measures during and after re-processing of the internal breathing-circuit-system. These results support an extension of the re-processing interval of the anesthesia apparatus longer than the manufacturer’s recommendation of one week. However, the importance of adherence to standard hygienic measures during re-processing needs to be emphasized. PMID:22242095

  17. Submarines, Spacecraft, and Exhaled Breath

    Science.gov (United States)

    The International Association of Breath Research (IABR) meetings are an eclectic gathering of researchers in the medical, environmental and instrumentation fields; our focus is on human health as assessed by the measurement and interpretation of trace chemicals in human exhaled b...

  18. Breath-holding and its breakpoint.

    Science.gov (United States)

    Parkes, M J

    2006-01-01

    This article reviews the basic properties of breath-holding in humans and the possible causes of the breath at breakpoint. The simplest objective measure of breath-holding is its duration, but even this is highly variable. Breath-holding is a voluntary act, but normal subjects appear unable to breath-hold to unconsciousness. A powerful involuntary mechanism normally overrides voluntary breath-holding and causes the breath that defines the breakpoint. The occurrence of the breakpoint breath does not appear to be caused solely by a mechanism involving lung or chest shrinkage, partial pressures of blood gases or the carotid arterial chemoreceptors. This is despite the well-known properties of breath-hold duration being prolonged by large lung inflations, hyperoxia and hypocapnia and being shortened by the converse manoeuvres and by increased metabolic rate. Breath-holding has, however, two much less well-known but important properties. First, the central respiratory rhythm appears to continue throughout breath-holding. Humans cannot therefore stop their central respiratory rhythm voluntarily. Instead, they merely suppress expression of their central respiratory rhythm and voluntarily 'hold' the chest at a chosen volume, possibly assisted by some tonic diaphragm activity. Second, breath-hold duration is prolonged by bilateral paralysis of the phrenic or vagus nerves. Possibly the contribution to the breakpoint from stimulation of diaphragm muscle chemoreceptors is greater than has previously been considered. At present there is no simple explanation for the breakpoint that encompasses all these properties.

  19. Analysis of human breath with micro extraction techniques and continuous monitoring of carbon dioxide concentration.

    Science.gov (United States)

    Ma, Wei; Liu, Xinyu; Pawliszyn, Janusz

    2006-08-01

    The detection of volatile organic compounds (VOCs) in human breath can be useful for the clinical routine diagnosis of several diseases in a non-invasive manner. Traditional methods of breath analysis have some major technical problems and limitations. Membrane extraction with a sorbent interface (MESI), however, has many advantages over current methods, including good selectivity and sensitivity, and is well suited for breath analysis. The aim of this project was to develop a simple and reproducible sampling device and method based on the MESI system for breath analysis. The feasibility and validity of the MESI system was tested with real human breath samples. Internal standard calibration methods were used for the quantitative analysis of various breath samples. Calibration curves for some main components (target analytes such as acetone and pentane) were determined in the research. The optimized stripping-side and feeding-side gas velocities were determined. The use of breath CO2 as an internal standard for the analysis of breath VOCs is an effective method to solve the difficulties associated with variations in the target analyte concentrations in a sample, which are attributed to mass losses and different breathing patterns of different subjects. In this study, the concentration of breath acetone was successfully expressed normalized to CO2 as in the alveolar air. Breath acetone of healthy males and females profiled at different times of the day was plotted using the MESI system, and results were consistent with the literature. This technique can be used for monitoring breath acetone concentrations of diabetic patients and for applications with other biomarker monitoring.

  20. Changes in breathing while listening to read speech: the effect of reader and speech mode.

    Science.gov (United States)

    Rochet-Capellan, Amélie; Fuchs, Susanne

    2013-01-01

    The current paper extends previous work on breathing during speech perception and provides supplementary material regarding the hypothesis that adaptation of breathing during perception "could be a basis for understanding and imitating actions performed by other people" (Paccalin and Jeannerod, 2000). The experiments were designed to test how the differences in reader breathing due to speaker-specific characteristics, or differences induced by changes in loudness level or speech rate influence the listener breathing. Two readers (a male and a female) were pre-recorded while reading short texts with normal and then loud speech (both readers) or slow speech (female only). These recordings were then played back to 48 female listeners. The movements of the rib cage and abdomen were analyzed for both the readers and the listeners. Breathing profiles were characterized by the movement expansion due to inhalation and the duration of the breathing cycle. We found that both loudness and speech rate affected each reader's breathing in different ways. Listener breathing was different when listening to the male or the female reader and to the different speech modes. However, differences in listener breathing were not systematically in the same direction as reader differences. The breathing of listeners was strongly sensitive to the order of presentation of speech mode and displayed some adaptation in the time course of the experiment in some conditions. In contrast to specific alignments of breathing previously observed in face-to-face dialog, no clear evidence for a listener-reader alignment in breathing was found in this purely auditory speech perception task. The results and methods are relevant to the question of the involvement of physiological adaptations in speech perception and to the basic mechanisms of listener-speaker coupling.

  1. Neural mechanisms underlying breathing complexity.

    Directory of Open Access Journals (Sweden)

    Agathe Hess

    Full Text Available Breathing is maintained and controlled by a network of automatic neurons in the brainstem that generate respiratory rhythm and receive regulatory inputs. Breathing complexity therefore arises from respiratory central pattern generators modulated by peripheral and supra-spinal inputs. Very little is known on the brainstem neural substrates underlying breathing complexity in humans. We used both experimental and theoretical approaches to decipher these mechanisms in healthy humans and patients with chronic obstructive pulmonary disease (COPD. COPD is the most frequent chronic lung disease in the general population mainly due to tobacco smoke. In patients, airflow obstruction associated with hyperinflation and respiratory muscles weakness are key factors contributing to load-capacity imbalance and hence increased respiratory drive. Unexpectedly, we found that the patients breathed with a higher level of complexity during inspiration and expiration than controls. Using functional magnetic resonance imaging (fMRI, we scanned the brain of the participants to analyze the activity of two small regions involved in respiratory rhythmogenesis, the rostral ventro-lateral (VL medulla (pre-Bötzinger complex and the caudal VL pons (parafacial group. fMRI revealed in controls higher activity of the VL medulla suggesting active inspiration, while in patients higher activity of the VL pons suggesting active expiration. COPD patients reactivate the parafacial to sustain ventilation. These findings may be involved in the onset of respiratory failure when the neural network becomes overwhelmed by respiratory overload We show that central neural activity correlates with airflow complexity in healthy subjects and COPD patients, at rest and during inspiratory loading. We finally used a theoretical approach of respiratory rhythmogenesis that reproduces the kernel activity of neurons involved in the automatic breathing. The model reveals how a chaotic activity in

  2. Reliability of Diagnostic Tests for Helicobacter pylori Infection

    Directory of Open Access Journals (Sweden)

    S. Redéen

    2011-01-01

    Full Text Available Introduction. Helicobacter pylori (H. pylori infection is very common worldwide. A reliable diagnosis is crucial for patients with H. pylori-related diseases. At followup, it is important to confirm that eradication therapy has been successful. There is no established gold standard for the diagnosis of H. pylori infection. Material and Methods. A sample of 304 volunteers from the general population was screened for H. pylori infection with serology, 13C-urea breath test (UBT, rapid urease test (RUT on fresh biopsy, culture from biopsy, and histological examination. Culture was used as gold standard. Results. The sensitivity was 0.99 for serology, 0.90 for UBT, 0.90 for RUT, and 0.90 for histological examination. Corresponding specificities were 0.82, 0.99, 0.98, and 0.97, respectively. The accuracy was 0.86 for serology, 0.96 for UBT, 0.95 for RUT, 0.93 for culture, and 0.95 for histology. There was a strong correlation between the results of UBT and the histological scores of H. pylori colonisation as well as between the results of UBT and the scores of RUT. Conclusion. There were only minor differences in accuracy between the three invasive tests for H. pylori infection in this population. RUT may be recommended as the first choice since a result is obtained within hours. The accuracy of UBT was comparable to the invasive tests, and it is recommended for situations when endoscopy is not needed.

  3. Breath analysis: clinical research to the end-user market.

    Science.gov (United States)

    Smith, T

    2011-09-01

    Breath research is now well established and is solving some of the applications in the area of identifying volatiles for medical diagnosis. This paper looks at how this research has been taken to an end-user market. It is not intended to be an indepth study of the science but simply to draw attention to the role of the commercial link between the researcher and end-user. This market is not only in research but exists in hospitals, clinics, sports medicine and even homecare. The link between research and the end-user market is a vital one to avoid breath analysis being the tool of researchers only. The ubiquitous use of breath analysis depends upon it. This is a review of some of the success stories in commercializing the important breath analysis research that has been conducted over the last few decades. In order to make breath analysis the new blood test, products that have end-user appeal need to be developed and routes to market established.

  4. Effect of etiology of mouth breathing on craniofacial morphology

    Directory of Open Access Journals (Sweden)

    Mohammadreza Majidi

    2008-07-01

    Full Text Available Introduction: Nasal septal deviation and hypertrophy of the adenoids and palatine tonsils are two common causes of nasopharyngeal obstruction and consequently mouth breathing in children. It is accepted that chronic mouth breathing influences craniofacial growth and development. The aim of this study was to evaluate the differences of craniofacial morphology in children with two different etiological factors of mouth breathing. Materials and Methods: Study design: cross sectional. The research was conducted between 2005-2007 on 47 predominantly mouth breathing patients aged 6-10 years. After otorhinolaryngologic examination, patients were divided into two groups based on the etiology of nasopharyngeal obstruction: group 1, with Adenoid hypertrophy and group 2 with nasal septal deviation. Lateral cephalometric radiographs were obtained to assess craniofacial development. Data gained were statistically evaluated by Mann-Whitney and T-student tests. Results: With respect to the inclination of the mandibular and palatal planes, anteroposterior relationship of maxilla and mandible to the cranial base, and indexes of facial height proportions, no significant differences were observed between two groups of children with mouth breathing. Only the gonial and craniocervical angle measurements were significantly larger in children with adenoid hypertrophy (P

  5. Waldorf Education: Breathing Creativity

    Science.gov (United States)

    Nordlund, Carrie

    2013-01-01

    After 10 years of teaching art in public schools, Carrie Nordlund arrived at a state of query that set in motion her search for alternative approaches to learning. As she was feeling stifled in a seemingly sterile education institution with its overdependence on and pedagogy aimed at standardized tests, she came across a reference to Waldorf…

  6. Effects of high-frequency yoga breathing called kapalabhati compared with breath awareness on the degree of optical illusion perceived.

    Science.gov (United States)

    Telles, Shirley; Maharana, Kanchan; Balrana, Budhi; Balkrishna, Acharya

    2011-06-01

    Prior research has shown that methods of meditation, breath control, and different kinds of yoga breathing affect attention and visual perception, including decreasing the size of certain optical illusions. Evaluating relationships sheds light on the perceptual and cognitive changes induced by yoga and related methods, and the locus of the effects. In the present study, the degree of optical illusion was assessed using Müller-Lyer stimuli before and immediately after two different kinds of practice, a high frequency yoga breathing called kapalabhati, and breath awareness. A nonyoga, control session tested for practice effects. Thirty participants (with group M age = 26.9 yr., SD = 5.7) practiced the two techniques for 18 min. on two separate days. The control group had 15 nonyoga practitioners assessed before and after 18 min. in which they did not perform any specific activity but were seated and relaxed. After both kapalabhati and breath awareness there was a significant decrease in the degree of optical illusion. The possibility that this was due to a practice or repetition effect was ruled out when 15 nonyoga practitioners showed no change in the degree of illusion when retested after 18 min. The changes were interpreted as due to changes in perception related to the way the stimuli were judged.

  7. [Stahl, Leibniz, Hoffmann and breathing].

    Science.gov (United States)

    Carvallo, Sarah

    2006-01-01

    At the beginning of the XVIII th century, Wilhelm Gottfried Leibniz and Friedrich Hoffmann criticize Georg Ernst Stahl's medical theory. They differenciate between unsound and true reasonings. Namely, they validate Stahl's definition of breath but extracting it from its animist basis and placing it in an epistemology obeying to the principle of sufficient reason and to the mechanical model. The stahlian discovery consists in understanding breath as a calorific ventilation against the ancient conception; the iatromechanists recognize its accuracy, but they try then to transpose it to a mechanical model of ventilation. Using it in a different epistemological context implies that they analyze the idea of discovery "true" in its contents, but "wrong" in its hypothesis. It impels to examine the epistemology of medical knowledge, as science and therapeutics, and in its links with the other scientific theories. Thus, if Leibniz as philosopher and Hoffmann as doctor consider Stahl's animism so important, it is because its discoveries question the fundamental principles of medicine.

  8. Effects of diaphragm breathing exercise and feedback breathing exercise on pulmonary function in healthy adults.

    Science.gov (United States)

    Yong, Min-Sik; Lee, Hae-Yong; Lee, Yun-Seob

    2017-01-01

    [Purpose] The present study investigated effects of diaphragm breathing exercise and feedback breathing exercise on respiratory function. [Subjects and Methods] Thirty-one subjects were randomly assigned to two groups; the feedback breathing exercise group and the maneuver-diaphragm exercise group. The feedback breathing exercise group was asked to breathe with feedback breathing device, and the maneuver-diaphragm exercise group was asked to perform diaphragm respiration. Respiratory function was evaluated when a subject sat on a chair comfortably. [Results] There was a significant difference in the functional vital capacity and slow vital capacity before and after all breathing exercises. There was a significant between-group difference in functional vital capacity. However, no between-group difference was found in slow vital capacity. [Conclusion] Diaphragm breathing exercise and feedback breathing exercise can affect respiratory function.

  9. Breathing Modes in Dusty Plasma

    Institute of Scientific and Technical Information of China (English)

    王晓钢; 王爽; 潘秋惠; 刘悦; 贺明峰

    2003-01-01

    Acoustic breathing modes of dusty plasmas have been investigated in a cylindricalsystem with an axial symmetry. The linear wave solution and a "dispersion" relation were derived.It was found that in an infinite area, the mode is reduced to a "classical" dust acoustic wave inthe region away from the center. If the dusty plasma is confined in a finite region, however, thebreathing (or heart-beating) behavior would be found as observed in many experiments.

  10. Stool antigen tests in the diagnosis of Helicobacter pylori infection before and after eradication therapy

    Institute of Scientific and Technical Information of China (English)

    Lea Veijola; Eveliina Myllyluoma; Riitta Korpela; Hilpi Rautelin

    2005-01-01

    Aim: To evaluate two enzyme immunoassay-based stool antigen tests, Premier Platinum HpSA and Amplified IDEIA HpStAR, and one rapid test, ImmunoCard STAT! HpSA, in the primary diagnosis of Helicobacter pylori (H pylori) infection and after eradication therapy.METHODS: Altogether 1 574 adult subjects were screened with a whole-blood H pylori antibody test and positive results were confirmed with locally validated serology and 13C-urea breath test. All 185 subjects,confirmed to be H pylori positive, and 97 H pylorinegative individuals, randomly selected from the screened study population and with negative results in serology and UBT, were enrolled. After eradication therapy the results of 182 subjects were assessed.RESULTS: At baseline, the sensitivity of HpSA and HpStAR was 91.9% and 96.2%, respectively, and specificity was 95.9% for both tests. ImmunoCard had sensitivity of 93.0% but specificity of only 88.7%. After eradication therapy, HpSA and HpStAR had sernsitivity of 81.3% and 100%, and specificity of 97.0% and 97.6%,respectively. ImmunoCard had sensitivity of 93.8% and specificity of 97.0%. HpSA, HpStAR, and ImmunoCard had PPV 77%, 80%, and 75%, and NPV 98%, 100%,and 99%, respectively.CONCLUSION: In primary diagnosis, the EIA-based tests performed well. After eradication therapy, negative results were highly accurate for all the three tests.HpStAR had the best overall performance.

  11. Running and Breathing in Mammals

    Science.gov (United States)

    Bramble, Dennis M.; Carrier, David R.

    1983-01-01

    Mechanical constraints appear to require that locomotion and breathing be synchronized in running mammals. Phase locking of limb and respiratory frequency has now been recorded during treadmill running in jackrabbits and during locomotion on solid ground in dogs, horses, and humans. Quadrupedal species normally synchronize the locomotor and respiratory cycles at a constant ratio of 1:1 (strides per breath) in both the trot and gallop. Human runners differ from quadrupeds in that while running they employ several phase-locked patterns (4:1, 3:1, 2:1, 1:1, 5:2, and 3:2), although a 2:1 coupling ratio appears to be favored. Even though the evolution of bipedal gait has reduced the mechanical constraints on respiration in man, thereby permitting greater flexibility in breathing pattern, it has seemingly not eliminated the need for the synchronization of respiration and body motion during sustained running. Flying birds have independently achieved phase-locked locomotor and respiratory cycles. This hints that strict locomotor-respiratory coupling may be a vital factor in the sustained aerobic exercise of endothermic vertebrates, especially those in which the stresses of locomotion tend to deform the thoracic complex.

  12. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    DEFF Research Database (Denmark)

    Domenici, Paolo; Norin, Tommy; Bushnell, Peter G.;

    2015-01-01

    acceleration away from the stimulus. Recently, similar C-starts have been recorded in fish aiming at a prey. Little is known about C-starts outside the context of predator–prey interactions, though recent work has shown that escape response can also be induced by high temperature. Here, we test the hypothesis...... that air-breathing fish may use C-starts in the context of gulping air at the surface. Hoplosternum littorale is an air-breathing freshwater catfish found in South America. Field video observations reveal that their air-breathing behaviour consists of air-gulping at the surface, followed by a fast turn...

  13. Variability in the blood/breath alcohol ratio and implications for evidentiary purposes.

    Science.gov (United States)

    Jaffe, Dena H; Siman-Tov, Maya; Gopher, Asher; Peleg, Kobi

    2013-09-01

    The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21-37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field-tested conditions.

  14. Guidelines proposal for clinical recognition of mouth breathing children

    Directory of Open Access Journals (Sweden)

    Maria Christina Thomé Pacheco

    2015-08-01

    Full Text Available INTRODUCTION: Mouth breathing (MB is an etiological factor for sleep-disordered breathing (SDB during childhood. The habit of breathing through the mouth may be perpetuated even after airway clearance. Both habit and obstruction may cause facial muscle imbalance and craniofacial changes.OBJECTIVE: The aim of this paper is to propose and test guidelines for clinical recognition of MB and some predisposing factors for SDB in children.METHODS: Semi-structured interviews were conducted with 110 orthodontists regarding their procedures for clinical evaluation of MB and their knowledge about SDB during childhood. Thereafter, based on their answers, guidelines were developed and tested in 687 children aged between 6 and 12 years old and attending elementary schools.RESULTS: There was no standardization for clinical recognition of MB among orthodontists. The most common procedures performed were inefficient to recognize differences between MB by habit or obstruction.CONCLUSIONS: The guidelines proposed herein facilitate clinical recognition of MB, help clinicians to differentiate between habit and obstruction, suggest the most appropriate treatment for each case, and avoid maintenance of mouth breathing patterns during adulthood.

  15. Breathing Air Purification for Hyperbaric Purposes, Part II

    Directory of Open Access Journals (Sweden)

    Woźniak Arkadiusz

    2015-03-01

    Full Text Available Determining the efficiency of breathing air purification for hyperbaric purposes with the use of filtration systems is of a crucial importance. However, when the Polish Navy took samples of breathing air from their own filtration plant for quality purposes, these were found to not meet the required standard. The identification of this problem imposed the need to undertake actions aimed at the elimination of the identified disruptions in the process of breathing air production, with the objective of assuring its proper quality. This study presents the results of the initial tests on the air supply sources utilised by the Polish Navy, which were carried out for the purpose of setting a proper direction of future works and implementing corrective measures in order to optimise the breathing air production process. The obtained test results will be used in a subsequent publication devoted to the assessment of the level of efficiency of air purification with the use of a multifaceted approach consisting in the utilisation of various types of air supply sources and different configurations of purification systems.

  16. Reprint of "Breathing and sense of self: visuo-respiratory conflicts alter body self-consciousness".

    Science.gov (United States)

    Adler, Dan; Herbelin, Bruno; Similowski, Thomas; Blanke, Olaf

    2014-12-01

    Bodily self-consciousness depends on the processing of interoceptive and exteroceptive signals. It can be disrupted by inducing signal conflicts. Breathing, at the crossroad between interoception and exteroception, should contribute to bodily self-consciousness. We induced visuo-respiratory conflicts in 17 subjects presented with a virtual body or a parallelepidedal object flashing synchronously or asynchronously with their breathing. A questionnaire detected illusory changes in bodily self-consciousness and breathing agency (the feeling of sensing one's breathing command). Changes in self-location were tested by measuring reaction time during mental ball drop (MBD). Synchronous illumination changed the perceived location of breathing (body: p=0.008 vs. asynchronous; object: p=0.013). It resulted in a significant change in breathing agency, but no changes in self-identification. This was corroborated by prolonged MBD reaction time (body: +0.045s, 95%CI [0.013; 0.08], p=0.007). We conclude that breathing modulates bodily self-consciousness. We also conclude that one can induce the irruption of unattended breathing into consciousness without modifying respiratory mechanics or gas exchange.

  17. Breathing and sense of self: visuo-respiratory conflicts alter body self-consciousness.

    Science.gov (United States)

    Adler, Dan; Herbelin, Bruno; Similowski, Thomas; Blanke, Olaf

    2014-11-01

    Bodily self-consciousness depends on the processing of interoceptive and exteroceptive signals. It can be disrupted by inducing signal conflicts. Breathing, at the crossroad between interoception and exteroception, should contribute to bodily self-consciousness. We induced visuo-respiratory conflicts in 17 subjects presented with a virtual body or a parallelepidedal object flashing synchronously or asynchronously with their breathing. A questionnaire detected illusory changes in bodily self-consciousness and breathing agency (the feeling of sensing one's breathing command). Changes in self-location were tested by measuring reaction time during mental ball drop (MBD). Synchronous illumination changed the perceived location of breathing (body: p=0.008 vs. asynchronous; object: p=0.013). It resulted in a significant change in breathing agency, but no changes in self-identification. This was corroborated by prolonged MBD reaction time (body: +0.045s, 95%CI [0.013; 0.08], p=0.007). We conclude that breathing modulates bodily self-consciousness. We also conclude that one can induce the irruption of unattended breathing into consciousness without modifying respiratory mechanics or gas exchange.

  18. Study of the Human Breathing Flow Profile in a Room with three Different Ventilation Strategies

    DEFF Research Database (Denmark)

    Olmedo, Ines; Nielsen, Peter V.; de Adana, Manuel Ruiz;

    2010-01-01

    This study investigates the characteristics of human exhalation through the mouth with three different ventilation strategies: displacement ventilation, mixing ventilation and without ventilation. Experiments were conducted with one breathing thermal manikin in a full scale test room where the ex...

  19. Study of the Human Breathing Flow Profile with Three Different Ventilation Strategies

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Cortes, Ines Olmedo; Ruiz de Adana, Manuel

    2011-01-01

    This study investigates the characteristics of human exhalation through the mouth with three different ventilation strategies: displacement ventilation, mixing ventilation and without ventilation. Experiments were conducted with one breathing thermal manikin in a full scale test room where the ex...

  20. Cardiovascular and Respiratory Effect of Yogic Slow Breathing in the Yoga Beginner: What Is the Best Approach?

    Directory of Open Access Journals (Sweden)

    Heather Mason

    2013-01-01

    Full Text Available Slow breathing increases cardiac-vagal baroreflex sensitivity (BRS, improves oxygen saturation, lowers blood pressure, and reduces anxiety. Within the yoga tradition slow breathing is often paired with a contraction of the glottis muscles. This resistance breath “ujjayi” is performed at various rates and ratios of inspiration/expiration. To test whether ujjayi had additional positive effects to slow breathing, we compared BRS and ventilatory control under different breathing patterns (equal/unequal inspiration/expiration at 6 breath/min, with/without ujjayi, in 17 yoga-naive young healthy participants. BRS increased with slow breathing techniques with or without expiratory ujjayi ( or higher except with inspiratory + expiratory ujjayi. The maximal increase in BRS and decrease in blood pressure were found in slow breathing with equal inspiration and expiration. This corresponded with a significant improvement in oxygen saturation without increase in heart rate and ventilation. Ujjayi showed similar increase in oxygen saturation but slightly lesser improvement in baroreflex sensitivity with no change in blood pressure. The slow breathing with equal inspiration and expiration seems the best technique for improving baroreflex sensitivity in yoga-naive subjects. The effects of ujjayi seems dependent on increased intrathoracic pressure that requires greater effort than normal slow breathing.

  1. Sleep disordered breathing in pregnancy

    Directory of Open Access Journals (Sweden)

    Bilgay Izci Balserak

    2015-12-01

    Sleep disordered breathing (SDB is very common during pregnancy, and is most likely explained by hormonal, physiological and physical changes. Maternal obesity, one of the major risk factors for SDB, together with physiological changes in pregnancy may predispose women to develop SDB. SDB has been associated with poor maternal and fetal outcomes. Thus, early identification, diagnosis and treatment of SDB are important in pregnancy. This article reviews the pregnancy-related changes affecting the severity of SDB, the epidemiology and the risk factors of SDB in pregnancy, the association of SDB with adverse pregnancy outcomes, and screening and management options specific for this population.

  2. 42 CFR 84.79 - Breathing gas; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing gas; minimum requirements. 84.79 Section...-Contained Breathing Apparatus § 84.79 Breathing gas; minimum requirements. (a) Breathing gas used to supply... respiratory tract irritating compounds. (c) Compressed, gaseous breathing air shall meet the...

  3. 42 CFR 84.72 - Breathing tubes; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing tubes; minimum requirements. 84.72...-Contained Breathing Apparatus § 84.72 Breathing tubes; minimum requirements. Flexible breathing tubes used in conjunction with breathing apparatus shall be designed and constructed to prevent: (a)...

  4. 42 CFR 84.85 - Breathing bags; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bags; minimum requirements. 84.85 Section...-Contained Breathing Apparatus § 84.85 Breathing bags; minimum requirements. (a) Breathing bags shall have.... (b) Breathing bags shall be constructed of materials which are flexible and resistant to...

  5. Breath markers of oxidative stress in patients with unstable angina.

    Science.gov (United States)

    Phillips, Michael; Cataneo, Renee N; Greenberg, Joel; Grodman, Richard; Salazar, Manuel

    2003-01-01

    Cardiac chest pain is accompanied by oxidative stress, which generates alkanes and other volatile organic compounds (VOCs). These VOCs are excreted in the breath and could potentially provide a rational diagnostic marker of disease. The breath methylated alkane contour (BMAC), a 3-dimensional surface plot of C4-C20 alkanes and monomethylated alkanes, provides a comprehensive set of markers of oxidative stress. In this pilot study, we compared BMACs in patients with unstable angina pectoris and in healthy volunteers. Breath VOCs were analyzed in 30 patients with unstable angina confirmed by coronary angiography and in 38 age-matched healthy volunteers with no known history of heart disease (mean age +/- SD, 62.7 +/- 12.3 years and 62.5 +/- 10.0, not significant). BMACs in both groups were compared to identify the combination of VOCs that provided the best discrimination between the 2 groups. Forward stepwise entry discriminant analysis selected 8 VOCs to construct a predictive model that correctly classified unstable angina patients with sensitivity of 90% (27 of 30) and specificity of 73.7% (28 of 38). On cross-validation, sensitivity was 83.3% (25 of 30) and specificity was 71.1% (27 of 38). We conclude that the breath test distinguished between patients with unstable angina and healthy control subjects.

  6. Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults.

    Science.gov (United States)

    Spacek, Lisa A; Mudalel, Matthew; Tittel, Frank; Risby, Terence H; Solga, Steven F

    2015-12-01

    Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μmol L(-1) (interquartile range (IQR), 3-18) versus 46 μmol L(-1) (IQR, 23-66) for cirrhotic participants. Median breath ammonia was 379 pmol mL(-1) CO2 (IQR, 265-765) for healthy versus 350 pmol mL(-1) CO2 (IQR, 180-1013) for cirrhotic participants. CV was 17  ±  6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia.

  7. Breath isoprene concentrations in persons undergoing general anesthesia and in healthy volunteers.

    Science.gov (United States)

    Hornuss, Cyrill; Zagler, Armin; Dolch, Michael E; Wiepcke, Dirk; Praun, Siegfried; Boulesteix, Anne-Laure; Weis, Florian; Apfel, Christian C; Schelling, Gustav

    2012-12-01

    Human breath contains an abundance of volatile organic compounds (VOCs). Analysis of breath VOC may be used for diagnosis of various diseases or for on-line monitoring in anesthesia and intensive care. However, VOC concentrations largely depend on the breath sampling method and have a large inter-individual variability. For the development of breath tests, the influence of breath sampling methods and study subject characteristics on VOC concentrations has to be known. Therefore, we investigated the VOC isoprene in 62 study subjects during anesthesia and 16 spontaneously breathing healthy volunteers to determine (a) the influence of artificial and spontaneous ventilation and (b) the influence of study subject characteristics on breath isoprene concentrations. We used ion molecule reaction mass spectrometry for high-resolution breath-by-breath analysis of isoprene. We found that persons during anesthesia had significantly increased inspiratory and end-expiratory isoprene breath concentrations. Measured isoprene concentrations (median [first quartile-third quartile]) were in the anesthesia group: 54 [40-79] ppb (inspiratory) and 224 [171-309] ppb (end-expiratory), volunteer group: 14 [11-17] ppb (inspiratory) and 174 [124-202] ppb (end-expiratory). Higher end-tidal CO(2) concentrations in ventilated subjects were associated with higher expiratory isoprene levels. Furthermore, inspiratory and end-expiratory isoprene concentrations were correlated during anesthesia (r = 0.603, p < 0.001). Multivariate analysis showed that men had significantly higher end-expiratory isoprene concentrations than women. Rebreathing of isoprene from the anesthesia machine possibly accounts for the observed increase in isoprene in the anesthesia group.

  8. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    Directory of Open Access Journals (Sweden)

    Van Sickle David

    2008-03-01

    Full Text Available Abstract Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male. Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86 and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification.

  9. Breath acetone monitoring by portable Si:WO{sub 3} gas sensors

    Energy Technology Data Exchange (ETDEWEB)

    Righettoni, Marco; Tricoli, Antonio; Gass, Samuel [Particle Technology Laboratory, Department of Mechanical and Process Engineering ETH Zurich, CH-8092 Zurich (Switzerland); Schmid, Alex; Amann, Anton [Univ.-Clinic for Anesthesia, Innsbruck Medical University, A-6020 Innsbruck (Austria); Breath Research Institute of the Austrian Academy of Sciences, A-6850 Dornbirn (Austria); Pratsinis, Sotiris E., E-mail: sotiris.pratsinis@ptl.mavt.ethz.ch [Particle Technology Laboratory, Department of Mechanical and Process Engineering ETH Zurich, CH-8092 Zurich (Switzerland)

    2012-08-13

    Highlights: Black-Right-Pointing-Pointer Portable sensors were developed and tested for monitoring acetone in the human breath. Black-Right-Pointing-Pointer Acetone concentrations down to 20 ppb were measured with short response times (<30 s). Black-Right-Pointing-Pointer The present sensors were highly selective to acetone over ethanol and water. Black-Right-Pointing-Pointer Sensors were applied to human breath: good agreement with highly sensitive PTR-MS. Black-Right-Pointing-Pointer Tests with people at rest and during physical activity showed the sensor robustness. - Abstract: Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO{sub 3} nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone ({approx}20 ppb) with short response (10-15 s) and recovery times (35-70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80-90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques.

  10. Protective supplied breathing air garment

    Science.gov (United States)

    Childers, Edward L.; von Hortenau, Erik F.

    1984-07-10

    A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

  11. Submarines, spacecraft and exhaled breath.

    Science.gov (United States)

    Pleil, Joachim D; Hansel, Armin

    2012-03-01

    Foreword The International Association of Breath Research (IABR) meetings are an eclectic gathering of researchers in the medical, environmental and instrumentation fields; our focus is on human health as assessed by the measurement and interpretation of trace chemicals in human exhaled breath. What may have escaped our notice is a complementary field of research that explores the creation and maintenance of artificial atmospheres practised by the submarine air monitoring and air purification (SAMAP) community. SAMAP is comprised of manufacturers, researchers and medical professionals dealing with the engineering and instrumentation to support human life in submarines and spacecraft (including shuttlecraft and manned rockets, high-altitude aircraft, and the International Space Station (ISS)). Here, the immediate concerns are short-term survival and long-term health in fairly confined environments where one cannot simply 'open the window' for fresh air. As such, one of the main concerns is air monitoring and the main sources of contamination are CO(2) and other constituents of human exhaled breath. Since the inaugural meeting in 1994 in Adelaide, Australia, SAMAP meetings have been held every two or three years alternating between the North American and European continents. The meetings are organized by Dr Wally Mazurek (a member of IABR) of the Defense Systems Technology Organization (DSTO) of Australia, and individual meetings are co-hosted by the navies of the countries in which they are held. An overriding focus at SAMAP is life support (oxygen availability and carbon dioxide removal). Certainly, other air constituents are also important; for example, the closed environment of a submarine or the ISS can build up contaminants from consumer products, cooking, refrigeration, accidental fires, propulsion and atmosphere maintenance. However, the most immediate concern is sustaining human metabolism: removing exhaled CO(2) and replacing metabolized O(2). Another

  12. Atrial distension, arterial pulsation, and vasopressin release during negative pressure breathing in humans

    DEFF Research Database (Denmark)

    Pump, B; Damgaard, M; Gabrielsen, A;

    2001-01-01

    During an antiorthostatic posture change, left atrial (LA) diameter and arterial pulse pressure (PP) increase, and plasma arginine vasopressin (AVP) is suppressed. By comparing the effects of a 15-min posture change from seated to supine with those of 15-min seated negative pressure breathing...... in eight healthy males, we tested the hypothesis that with similar increases in LA diameter, suppression of AVP release is dependent on the degree of increase in PP. LA diameter increased similarly during the posture change and negative pressure breathing (-9 to -24 mmHg) from between 30 and 31 +/- 1 to 34...... +/- 1 mm (P breathing from 36 +/- 3 to 42 +/- 3 mmHg (P

  13. 42 CFR 84.141 - Breathing gas; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... Respirators § 84.141 Breathing gas; minimum requirements. (a) Breathing gas used to supply supplied-air respirators shall be respirable breathing air and contain no less than 19.5 volume-percent of oxygen....

  14. How Does a Hopping Kangaroo Breathe?

    Science.gov (United States)

    Giuliodori, Mauricio J.; Lujan, Heidi L.; Janbaih, Hussein; DiCarlo, Stephen E.

    2010-01-01

    We developed a model to demonstrate how a hopping kangaroo breathes. Interestingly, a kangaroo uses less energy to breathe while hopping than while standing still. This occurs, in part, because rather than using muscle power to move air into and out of the lungs, air is pulled into (inspiration) and pushed out of (expiration) the lungs as the…

  15. Controlled Frequency Breathing Reduces Inspiratory Muscle Fatigue.

    Science.gov (United States)

    Burtch, Alex R; Ogle, Ben T; Sims, Patrick A; Harms, Craig A; Symons, Thorburn B; Folz, Rodney J; Zavorsky, Gerald S

    2016-08-16

    Controlled frequency breathing (CFB) is a common swim training modality involving holding one's breath for about 7 to 10 strokes before taking another breath. We sought to examine the effects of CFB training on reducing respiratory muscle fatigue. Competitive college swimmers were randomly divided into either the CFB group that breathed every 7 to 10 strokes, or a control group that breathed every 3-4 strokes. Twenty swimmers completed the study. The training intervention included 5-6 weeks (16 sessions) of 12x50-m repetitions with breathing 8-10 breaths per 50m (control group), or 2-3 breaths per 50-m (CFB group). Inspiratory muscle fatigue was defined as the decrease in maximal inspiratory mouth-pressure (MIP) between rest and 46s after a 200 yard free-style swimming race [115s (SD 7)]. Aerobic capacity, pulmonary diffusing capacity, and running economy were also measured pre and post-training. Pooled results demonstrated a 12% decrease in MIP at 46s post-race [-15 (SD 14) cm H2O, Effect size = -0.48, p training, only the CFB group prevented a decline in MIP values pre to 46 s post-race [-2 (13) cm H2O, p > 0.05]. However, swimming performance, aerobic capacity, pulmonary diffusing capacity, and running economy did not improve (p > 0.05) post-training in either group. In conclusion, CFB training appears to prevent inspiratory muscle fatigue yet no difference was found in performance outcomes.

  16. Relationships between hippocampal activity and breathing patterns

    DEFF Research Database (Denmark)

    Harper, R M; Poe, G R; Rector, D M;

    1998-01-01

    Single cell discharge, EEG activity, and optical changes accompanying alterations in breathing patterns, as well as the knowledge that respiratory musculature is heavily involved in movement and other behavioral acts, implicate hippocampal regions in some aspects of breathing control. The control...

  17. The assessment of the breath hold and the free breath methods about the blood flow evaluation by using phase contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Ho [Dept. of Radiology, Konkuk Medical center, Seoul (Korea, Republic of)

    2016-06-15

    Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/ velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were 96.17±19.12 ml/sec, 17.04±4.12 cm/sec respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of 72.31±13.27 ml and 12.32±3.85. On the other hand, the average 2NEX blood flow and mean flow velocity is 101.90±24.09, 16.84±4.32, 3NEX 103.06±25.49, 16.88±4.19 did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were 76.68±19.72 ml/s, and 22.23±4.8, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

  18. Pulse pressure variation to predict fluid responsiveness in spontaneously breathing patients: tidal vs. forced inspiratory breathing.

    Science.gov (United States)

    Hong, D M; Lee, J M; Seo, J H; Min, J J; Jeon, Y; Bahk, J H

    2014-07-01

    We evaluated whether pulse pressure variation can predict fluid responsiveness in spontaneously breathing patients. Fifty-nine elective thoracic surgical patients were studied before induction of general anaesthesia. After volume expansion with hydroxyethyl starch 6 ml.kg(-1) , patients were defined as responders by a ≥ 15% increase in the cardiac index. Haemodynamic variables were measured before and after volume expansion and pulse pressure variations were calculated during tidal breathing and during forced inspiratory breathing. Median (IQR [range]) pulse pressure variation during forced inspiratory breathing was significantly higher in responders (n = 29) than in non-responders (n = 30) before volume expansion (18.2 (IQR 14.7-18.2 [9.3-31.3])% vs. 10.1 (IQR 8.3-12.6 [4.8-21.1])%, respectively, p breathing could predict fluid responsiveness (area under the curve 0.910, p breathing can be used to guide fluid management in spontaneously breathing patients.

  19. Discriminating between Nasal and Mouth Breathing

    CERN Document Server

    Curran, Kevin; Coyle, Damian

    2010-01-01

    The recommendation to change breathing patterns from the mouth to the nose can have a significantly positive impact upon the general well being of the individual. We classify nasal and mouth breathing by using an acoustic sensor and intelligent signal processing techniques. The overall purpose is to investigate the possibility of identifying the differences in patterns between nasal and mouth breathing in order to integrate this information into a decision support system which will form the basis of a patient monitoring and motivational feedback system to recommend the change from mouth to nasal breathing. Our findings show that the breath pattern can be discriminated in certain places of the body both by visual spectrum analysis and with a Back Propagation neural network classifier. The sound file recoded from the sensor placed on the hollow in the neck shows the most promising accuracy which is as high as 90%.

  20. Abortion--the breath of life.

    Science.gov (United States)

    Joling, R J

    1974-01-01

    A scholarly review of medical-legal and biblical authority on the su bject of abortion supports abortion as a woman's right when it is performed before the fetus has had its "breath of life." Based on biblical evidence, a person becomes a living being when the soul, the "breath of life" is breathed into it. Without the "breath of life" no person exists. A fetus less than 28 weeks old is incapable of breathing alone; thus an aborted fetus that age is not truly a living human being capable of surviving independently of its mother's womb. Legal aspects include supreme, local and state court decisions defining abortion. It is ultimately expected that each person will determine what approach to take towards the abortion question. Abortion is still a personal problem regardless of supreme court decisions or ecclesiastical determinants. Religion and moral concepts should be the guiding conscience involved in the question of abortion.

  1. Rapid eye movement sleep in breath holders.

    Science.gov (United States)

    Kohyama, J; Hasegawa, T; Shimohira, M; Fukumizu, M; Iwakawa, Y

    2000-07-01

    One-night polysomnography was performed on seven subjects suffering from breath-holding spells, including one whose death was suggested to be a consequence of a breath-holding spell. The fatal case showed no rapid eye movements (REMs) during REM sleep, although he exhibited REMs during wakefulness. The average numbers of both REMs and bursts of REMs in REM sleep in the other six breath holders were significantly lower than those in age-matched controls. The breath holders showed no airway obstruction, desaturation, or sleep fragmentation. Since the rapid ocular activity in REM sleep is generated in the brain stem, we hypothesized that a functional brainstem disturbance is involved in the occurrence of breath-holding spells.

  2. Treatment of Chronic Breath-Holding in an Adult with Severe Mental Retardation: A Clinical Case Study

    Science.gov (United States)

    Reed, Derek D.; Martens, Brian K.

    2008-01-01

    We describe a clinical case study surrounding the behavioral assessment and operant treatment of, an adult with severe mental retardation who engaged in chronic breath-holding. In this clinical case, previous neurological and medical testing had ruled out biological bases for the individual's breath-holding. A functional behavioral assessment…

  3. Evaluation of tracheal cuff pressure variation in spontaneously breathing patients

    OpenAIRE

    Plotnikow, Gustavo A; Roux, Nicolas; Feld, Viviana; Gogniat, Emiliano; Villalba, Dario; Ribero, Noelia Vairo; Sartore, Marisa; Bosso, Mauro; Quiroga, Corina; Leiva, Valeria; Scrigna, Mariana; Puchulu, Facundo; Distéfano, Eduardo; Scapellato, Jose Luis; Intile, Dante

    2013-01-01

    Background: Most of the studies referring cuff tubes’ issues were conducted on intubated patients. Not much is known about the cuff pressure performance in chronically tracheostomized patients disconnected from mechanical ventilation. Objective: To evaluate cuff pressure (CP) variation in tracheostomized, spontaneously breathing patients in a weaning rehabilitation center. Materials and Methods: Experimental setup to test instruments in vitro, in which the gauge (TRACOE) performance at differ...

  4. Time Breath of Psychological Theories

    DEFF Research Database (Denmark)

    Tateo, Luca; Valsiner, Jaan

    2015-01-01

    Psychology as a self-aspiring, ambitious, developmental science faces the crucial limit of time—both theoretically and practically. The issue of time in constructing psychology’s theories is a major unresolved metatheoretical task. This raises several questions about generalization of knowledge......: which is the time length of breath of psychological theories? Which is the temporal dimension of psychological processes? In this article we discuss the role of different axiomatic assumptions about time in the construction of psychological theories. How could different theories include a concept...... of time—or fail to do that? How can they generalize with respect to time? The different conceptions of time often remain implicit, while shaping the concepts used in understanding psychological processes. Any preconception about time in human development will foster the generalizability of theory, as well...

  5. Evaluation of oxygen saturation by pulse-oximetry in mouth breathing patients.

    Science.gov (United States)

    Niaki, Esfandiar Akhavan; Chalipa, Javad; Taghipoor, Elahe

    2010-01-01

    Mouth breathing might not always result in hypoxia, but can contribute to it. The aim of the present study was to determine the effect of mouth breathing on hypoxia. Based on a pilot study, 323 patients with mouth breathing were selected. Assessment of mouth breathing was based on clinical examination and questionnaires filled out by patients and their companions. The patients were also examined for further oral findings that could be attributable to mouth breathing. Oxygen saturation of each case was measured by means of a pulse oximetry device. The level of 95% saturation was set as the limit, under which the patient was considered hypoxemic. Acquired data was analyzed for descriptive data and frequency and also by means of the Chi-square and Spearman's correlation coefficient tests. 34.6% of the cases had normal O2 saturation. 65.4% of cases were hypoxemic (saturation level was below 95% in 42.8% and 95% in 22.6%). Most of the mouth breathing patients were male who were also more hypoxemic. A weak inverse relationship existed between the age of the patients and Oxygen saturation. Deep palatal vaults (29.4%) and gingival hyperplasia (29.2%) were the most frequent intraoral findings. Concerning the effects of hypoxia on body systems, the use of pulse oximetry in suspected mouth breathing patients could be recommended in routine oral and dental examinations.

  6. Evaluation of Oxygen Saturation by Pulse-Oximetry in Mouth Breathing Patients

    Directory of Open Access Journals (Sweden)

    Esfandiar Akhavan Niaki

    2010-02-01

    Full Text Available Mouth breathing might not always result in hypoxia, but can contribute to it. The aim of the present study was to determine the effect of mouth breathing on hypoxia. Based on a pilot study, 323 patients with mouth breathing were selected. Assessment of mouth breathing was based on clinical examination and questionnaires filled out by patients and their companions. The patients were also examined for further oral findings that could be attributable to mouth breathing. Oxygen saturation of each case was measured by means of a pulse oximetry device. The level of 95% saturation was set as the limit, under which the patient was considered hypoxemic. Acquired data was analyzed for descriptive data and frequency and also by means of the Chi-square and Spearman’s correlation coefficient tests.  34.6% of the cases had normal O2 saturation. 65.4% of cases were hypoxemic (saturation level was below 95% in 42.8% and 95% in 22.6%. Most of the mouth breathing patients were male who were also more hypoxemic.  A weak inverse relationship existed between the age of the patients and Oxygen saturation. Deep palatal vaults (29.4% and gingival hyperplasia (29.2% were the most frequent intraoral findings. Concerning the effects of hypoxia on body systems, the use of pulse oximetry in suspected mouth breathing patients could be recommended in routine oral and dental examinations.

  7. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction.

    Science.gov (United States)

    Cohen, K P; Ladd, W M; Beams, D M; Sheers, W S; Radwin, R G; Tompkins, W J; Webster, J G

    1997-07-01

    The goal of this study was to compare the relative performance of two noninvasive ventilation sensing technologies on adults during artifacts. We recorded changes in transthoracic impedance and cross-sectional area of the abdomen (abd) and rib cage (rc) using impedance pneumography (IP) and respiratory inductance plethysmography (RIP) on ten adult subjects during natural breathing, motion artifact, simulated airway obstruction, yawning, snoring, apnea, and coughing. We used a pneumotachometer to measure air flow and tidal volume as the standard. We calibrated all sensors during natural breathing, and performed measurements during all maneuvers without changing the calibration parameters. No sensor provided the most-accurate measure of tidal volume for all maneuvers. Overall, the combination of inductance sensors [RIP(sum)] calibrated during an isovolume maneuver had a bias (weighted mean difference) as low or lower than all individual sensors and all combinations of sensors. The IP(rc) sensor had a bias as low or lower than any individual sensor. The cross-correlation coefficient between sensors was high during natural breathing, but decreased during artifacts. The cross correlation between sensor pairs was lower during artifacts without breathing than it was during maneuvers with breathing for four different sensor combinations. We tested a simple breath-detection algorithm on all sensors and found that RIP(sum) resulted in the fewest number of false breath detections, with sensitivity of 90.8% and positive predictivity of 93.6%.

  8. How does breathing frequency affect the performance of an N95 filtering facepiece respirator and a surgical mask against surrogates of viral particles?

    Science.gov (United States)

    He, Xinjian; Reponen, Tiina; McKay, Roy; Grinshpun, Sergey A

    2014-01-01

    Breathing frequency (breaths/min) differs among individuals and levels of physical activity. Particles enter respirators through two principle penetration pathways: faceseal leakage and filter penetration. However, it is unknown how breathing frequency affects the overall performance of N95 filtering facepiece respirators (FFRs) and surgical masks (SMs) against viral particles, as well as other health-relevant submicrometer particles. A FFR and SM were tested on a breathing manikin at four mean inspiratory flows (MIFs) (15, 30, 55, and 85 L/min) and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). Filter penetration (Pfilter) and total inward leakage (TIL) were determined for the tested respiratory protection devices against sodium chloride (NaCl) aerosol particles in the size range of 20 to 500 nm. "Faceseal leakage-to-filter" (FLTF) penetration ratios were calculated. Both MIF and breathing frequency showed significant effects (p breathing frequency increased TIL for the N95 FFR whereas no clear trends were observed for the SM. Increasing MIF increased Pfilter and decreased TIL resulting in decreasing FLTF ratio. Most of FLTF ratios were >1, suggesting that the faceseal leakage was the primary particle penetration pathway at various breathing frequencies. Breathing frequency is another factor (besides MIF) that can significantly affect the performance of N95 FFRs, with higher breathing frequencies increasing TIL. No consistent trend of increase or decrease of TIL with either MIF or breathing frequency was observed for the tested SM. To potentially extend these findings beyond the manikin/breathing system used, future studies are needed to fully understand the mechanism causing the breathing frequency effect on the performance of respiratory protection devices on human subjects.

  9. Breathing Maneuvers as a Vasoactive Stimulus for Detecting Inducible Myocardial Ischemia – An Experimental Cardiovascular Magnetic Resonance Study

    Science.gov (United States)

    Fischer, Kady; Guensch, Dominik P; Shie, Nancy; Lebel, Julie; Friedrich, Matthias G

    2016-01-01

    Background Breathing maneuvers can elicit a similar vascular response as vasodilatory agents like adenosine; yet, their potential diagnostic utility in the presence of coronary artery stenosis is unknown. The objective of the study is to investigate if breathing maneuvers can non-invasively detect inducible ischemia in an experimental animal model when the myocardium is imaged with oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR). Methods and Findings In 11 anesthetised swine with experimentally induced significant stenosis (fractional flow reserve coronary artery (LAD) and 9 control animals, OS-CMR at 3T was performed during two different breathing maneuvers, a long breath-hold; and a combined maneuver of 60s of hyperventilation followed by a long breath-hold. The resulting change of myocardial oxygenation was compared to the invasive measurements of coronary blood flow, blood gases, and oxygen extraction. In control animals, all breathing maneuvers could significantly alter coronary blood flow as hyperventilation decreased coronary blood flow by 34±23%. A long breath-hold alone led to an increase of 97±88%, while the increase was 346±327% (pcoronary blood flow response was attenuated after both hyperventilation and the following breath-hold. This was matched by the observed oxygenation response as breath-holds following hyperventilation consistently yielded a significant difference in the signal of the MRI images between the perfusion territory of the stenosis LAD and remote myocardium. There was no difference between the coronary territories during the other breathing maneuvers or in the control group at any point. Conclusion In an experimental animal model, the response to a combined breathing maneuver of hyperventilation with subsequent breath-holding is blunted in myocardium subject to significant coronary artery stenosis. This maneuver may allow for detecting severe coronary artery stenosis and have a significant clinical potential as a

  10. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers.

    Science.gov (United States)

    Ngo, Chuong; Leonhardt, Steffen; Zhang, Tony; Lüken, Markus; Misgeld, Berno; Vollmer, Thomas; Tenbrock, Klaus; Lehmann, Sylvia

    2017-01-01

    Electrical impedance tomography (EIT) provides global and regional information about ventilation by means of relative changes in electrical impedance measured with electrodes placed around the thorax. In combination with lung function tests, e.g. spirometry and body plethysmography, regional information about lung ventilation can be achieved. Impedance changes strictly correlate with lung volume during tidal breathing and mechanical ventilation. Initial studies presumed a correlation also during forced expiration maneuvers. To quantify the validity of this correlation in extreme lung volume changes during forced breathing, a measurement system was set up and applied on seven lung-healthy volunteers. Simultaneous measurements of changes in lung volume using EIT imaging and pneumotachography were obtained with different breathing patterns. Data was divided into a synchronizing phase (spontaneous breathing) and a test phase (maximum effort breathing and forced maneuvers). The EIT impedance changes correlate strictly with spirometric data during slow breathing with increasing and maximum effort ([Formula: see text]) and during forced expiration maneuvers ([Formula: see text]). Strong correlations in spirometric volume parameters [Formula: see text] ([Formula: see text]), [Formula: see text]/FVC ([Formula: see text]), and flow parameters PEF, [Formula: see text], [Formula: see text], [Formula: see text] ([Formula: see text]) were observed. According to the linearity during forced expiration maneuvers, EIT can be used during pulmonary function testing in combination with spirometry for visualisation of regional lung ventilation.

  11. Breath Hydrogen as a Biomarker for Glucose Malabsorption after Roux-en-Y Gastric Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Iman Andalib

    2015-01-01

    Full Text Available Objective. Abdominal symptoms are common after bariatric surgery, and these individuals commonly have upper gut bacterial overgrowth, a known cause of malabsorption. Breath hydrogen determination after oral glucose is a safe and inexpensive test for malabsorption. This study is designed to investigate breath hydrogen levels after oral glucose in symptomatic individuals who had undergone Roux-en-Y gastric bypass surgery. Methods. This is a retrospective study of individuals (n=63; 60 females; 3 males; mean age 49 years who had gastric bypass surgery and then glucose breath testing to evaluate abdominal symptoms. Results. Among 63 postoperative individuals, 51 (81% had a late rise (≥45 minutes in breath hydrogen or methane, supporting glucose malabsorption; 46 (90% of these 51 subjects also had an early rise (≤30 minutes in breath hydrogen or methane supporting upper gut bacterial overgrowth. Glucose malabsorption was more frequent in subjects with upper gut bacterial overgrowth compared to subjects with no evidence for bacterial overgrowth (P<0.001. Conclusion. These data support the presence of intestinal glucose malabsorption associated with upper gut bacterial overgrowth in individuals with abdominal symptoms after gastric bypass surgery. Breath hydrogen testing after oral glucose should be considered to evaluate potential malabsorption in symptomatic, postoperative individuals.

  12. An Ultrasonic Contactless Sensor for Breathing Monitoring

    Directory of Open Access Journals (Sweden)

    Philippe Arlotto

    2014-08-01

    Full Text Available The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respiratory activity. However, this method has serious drawbacks. Indeed, as the subject should sleep overnight in a laboratory and because of sensors being in direct contact with him, artifacts modifying sleep quality are often observed. This work investigates an analysis of the viability of an ultrasonic device to quantify the breathing activity, without contact and without any perception by the subject. Based on a low power ultrasonic active source and transducer, the device measures the frequency shift produced by the velocity difference between the exhaled air flow and the ambient environment, i.e., the Doppler effect. After acquisition and digitization, a specific signal processing is applied to separate the effects of breath from those due to subject movements from the Doppler signal. The distance between the source and the sensor, about 50 cm, and the use of ultrasound frequency well above audible frequencies, 40 kHz, allow monitoring the breathing activity without any perception by the subject, and therefore without any modification of the sleep quality which is very important for sleep disorders diagnostic applications. This work is patented (patent pending 2013-7-31 number FR.13/57569.

  13. An ultrasonic contactless sensor for breathing monitoring.

    Science.gov (United States)

    Arlotto, Philippe; Grimaldi, Michel; Naeck, Roomila; Ginoux, Jean-Marc

    2014-08-20

    The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respiratory activity. However, this method has serious drawbacks. Indeed, as the subject should sleep overnight in a laboratory and because of sensors being in direct contact with him, artifacts modifying sleep quality are often observed. This work investigates an analysis of the viability of an ultrasonic device to quantify the breathing activity, without contact and without any perception by the subject. Based on a low power ultrasonic active source and transducer, the device measures the frequency shift produced by the velocity difference between the exhaled air flow and the ambient environment, i.e., the Doppler effect. After acquisition and digitization, a specific signal processing is applied to separate the effects of breath from those due to subject movements from the Doppler signal. The distance between the source and the sensor, about 50 cm, and the use of ultrasound frequency well above audible frequencies, 40 kHz, allow monitoring the breathing activity without any perception by the subject, and therefore without any modification of the sleep quality which is very important for sleep disorders diagnostic applications. This work is patented (patent pending 2013-7-31 number FR.13/57569).

  14. Breathing and sleep at high altitude.

    Science.gov (United States)

    Ainslie, Philip N; Lucas, Samuel J E; Burgess, Keith R

    2013-09-15

    We provide an updated review on the current understanding of breathing and sleep at high altitude in humans. We conclude that: (1) progressive changes in pH initiated by the respiratory alkalosis do not underlie early (48 h), complex cellular and neurochemical re-organization occurs both in the peripheral chemoreceptors as well as within the central nervous system. The latter is likely influenced by central acid-base changes secondary to the extent of the initial respiratory responses to initial exposure to high altitude; (3) sleep at high altitude is disturbed by various factors, but principally by periodic breathing; (4) the extent of periodic breathing during sleep at altitude intensifies with duration and severity of exposure; (5) complex interactions between hypoxic-induced enhancement in peripheral and central chemoreflexes and cerebral blood flow--leading to higher loop gain and breathing instability--underpin this development of periodic breathing during sleep; (6) because periodic breathing may elevate rather than reduce mean SaO2 during sleep, this may represent an adaptive rather than maladaptive response; (7) although oral acetazolamide is an effective means to reduce periodic breathing by 50-80%, recent studies using positive airway pressure devices to increase dead space, hyponotics and theophylline are emerging but appear less practical and effective compared to acetazolamide. Finally, we suggest avenues for future research, and discuss implications for understanding sleep pathology.

  15. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.

    Science.gov (United States)

    Lu, Yan; Niu, Wenqi; Zou, Xue; Shen, Chengyin; Xia, Lei; Huang, Chaoqun; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2017-03-23

    Breath analysis is a non-invasive approach which may be applied to disease diagnosis and pharmacokinetic study. In the case of offline analysis, the exhaled gas needs to be collected and the sampling bag is often used as the storage vessel. However, the sampling bag usually releases some extra compounds, which may interfere with the result of the breath test. In this study, a novel breath sampling glass bottle was developed with a syringe needle sampling port for solid phase microextraction (SPME). Such a glass bottle scarcely liberates compounds and can be used to collect exhaled gas for ensuing analysis by gas chromatography-mass spectrometry (GC-MS). The glass bottle sampling SPME-GC-MS analysis was carried out to investigate the breath metabolites of myrtol, a multicompound drug normally used in the treatment of bronchitis and sinusitis. Four compounds, α-pinene, 2,3-dehydro-1,8-cineole, d-limonene and 1,8-cineole were found in the exhaled breath of all eight volunteers who had taken the myrtol. While for other ten subjects who had not used the myrtol, these compounds were undetectable. In the SPME-GC-MS analysis of the headspace of myrtol, three compounds were detected including α-pinene, d-limonene and 1,8-cineole. Comparing the results of breath and headspace analysis, it indicates that 2,3-dehydro-1,8-cineole in the breath is the metabolite of 1,8-cineole. It is the first time that this metabolite was identified in human breath. The study demonstrates that the glass bottle sampling SPME-GC-MS method is applicable to exhaled gas analysis including breath metabolites investigation of drugs like myrtol.

  16. Slow breathing and hypoxic challenge: cardiorespiratory consequences and their central neural substrates.

    Science.gov (United States)

    Critchley, Hugo D; Nicotra, Alessia; Chiesa, Patrizia A; Nagai, Yoko; Gray, Marcus A; Minati, Ludovico; Bernardi, Luciano

    2015-01-01

    Controlled slow breathing (at 6/min, a rate frequently adopted during yoga practice) can benefit cardiovascular function, including responses to hypoxia. We tested the neural substrates of cardiorespiratory control in humans during volitional controlled breathing and hypoxic challenge using functional magnetic resonance imaging (fMRI). Twenty healthy volunteers were scanned during paced (slow and normal rate) breathing and during spontaneous breathing of normoxic and hypoxic (13% inspired O2) air. Cardiovascular and respiratory measures were acquired concurrently, including beat-to-beat blood pressure from a subset of participants (N = 7). Slow breathing was associated with increased tidal ventilatory volume. Induced hypoxia raised heart rate and suppressed heart rate variability. Within the brain, slow breathing activated dorsal pons, periaqueductal grey matter, cerebellum, hypothalamus, thalamus and lateral and anterior insular cortices. Blocks of hypoxia activated mid pons, bilateral amygdalae, anterior insular and occipitotemporal cortices. Interaction between slow breathing and hypoxia was expressed in ventral striatal and frontal polar activity. Across conditions, within brainstem, dorsal medullary and pontine activity correlated with tidal volume and inversely with heart rate. Activity in rostroventral medulla correlated with beat-to-beat blood pressure and heart rate variability. Widespread insula and striatal activity tracked decreases in heart rate, while subregions of insular cortex correlated with momentary increases in tidal volume. Our findings define slow breathing effects on central and cardiovascular responses to hypoxic challenge. They highlight the recruitment of discrete brainstem nuclei to cardiorespiratory control, and the engagement of corticostriatal circuitry in support of physiological responses that accompany breathing regulation during hypoxic challenge.

  17. Clinical comparison of Colgate Total Advanced Fresh vs a commercially available fluoride breath-freshening toothpaste in reducing breath odor overnight: a multiple-use study.

    Science.gov (United States)

    Niles, Hollandra P; Hunter, Catherine M; Vazquez, Joe; Williams, Malcolm I; Cummins, Diane

    2003-09-01

    The objective of this randomized, crossover study was to compare the effectiveness of Colgate Total Advanced Fresh toothpaste to a commercially available breath-freshening dentifrice containing fluoride for its ability to reduce volatile sulfur compounds (VSC) responsible for breath odor overnight. The study followed a two-treatment, two-period crossover design. Subjects were given a test product, along with a soft-bristled toothbrush, and instructed to brush their teeth for 1 minute, twice daily (once in the morning and the evening) using the assigned dentifrice for 7 consecutive days. After their evening brushing on the seventh day, subjects reported to the testing facility without oral hygiene, eating, or drinking for the overnight evaluation. After a washout period, subjects repeated the same regimen, now using the other test product. The levels of breath VSC were evaluated instrumentally using a gas chromatograph equipped with a flame photometric detector.

  18. Breath sound changes associated with malpositioned endotracheal tubes.

    Science.gov (United States)

    Mansy, H A; O'Connor, C J; Balk, R A; Sandler, R H

    2005-03-01

    Endotracheal tubes (ETTs) are used to establish airway access in patients with ventilatory failure and during general anaesthesia. Tube malpositioning can compromise respiratory function and can be associated with increased morbidity and mortality. Clinical assessment of ETT position normally involves chest auscultation, which is highly skill-dependent and can be misleading. The objective of this pilot study was to investigate breath sound changes associated with ETT malpositioning. Breath sounds were acquired in six human subjects over each hemithorax and over the epigastrium for tracheal, bronchial and oesophageal intubations. When the ETT was in the oesophagus, the acoustic energy ratio between epigastrium and chest surface increased in all subjects (p sounds may be useful for assessment of ETT positioning. More studies are needed to test the feasibility of this approach further.

  19. 46 CFR 197.456 - Breathing supply hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.456 Section 197.456 Shipping....456 Breathing supply hoses. (a) The diving supervisor shall insure that— (1) Each breathing supply....5 times its maximum working pressure; (2) Each breathing supply hose assembly, prior to being...

  20. Breathing exercises for adults with asthma.

    Science.gov (United States)

    2015-11-01

    Asthma is a common long-term condition that remains poorly controlled in many people despite the availability of pharmacological interventions, evidence-based treatment guidelines and care pathways.(1) There is considerable public interest in the use of non-pharmacological approaches for the treatment of asthma.(2) A survey of people with asthma reported that many have used complementary and alternative medicine, often without the knowledge of their clinical team.(3) Such interventions include breathing techniques, herbal products, homeopathy and acupuncture. The role of breathing exercises within the management of asthma has been controversial, partly because early claims of effectiveness were exaggerated.(4) UK national guidance and international guidelines on the management of asthma have included the option of breathing exercise programmes as an adjuvant to pharmacological treatment.(5,6) Here we discuss the types of breathing exercises used and review the evidence for their effectiveness.

  1. Fast and Accurate Exhaled Breath Ammonia Measurement

    OpenAIRE

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A.; Risby, Terence H.

    2014-01-01

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Toge...

  2. Evaluation of small intestine bacterial overgrowth in patients with functional dyspepsia through H2 breath test Avaliação de supercrescimento bacteriano no intestino delgado em pacientes com dispepsia funcional, utilizando o teste de H2 no ar expirado

    Directory of Open Access Journals (Sweden)

    Michelle Bafutto Gomes Costa

    2012-12-01

    Full Text Available CONTEXT: Functional dyspepsia is a condition in which symptoms are not related to organic underlying disease; its pathogenesis is not well known. The small intestinal bacterial overgrowth (SIBO is characterized by the increase in the number and/or type of colonic bacteria in the upper gastrointestinal tract. The hypothesis of SIBO being associated to functional dyspepsia must be considered, since the impaired motility of the gastrointestinal tract is one of the main etiologic factors involved on both pathologies. OBJECTIVE: To determine if there is SIBO in patients with functional dyspepsia. METHODS: Case-control study, evaluating 34 patients: 23 functional dyspeptic and 11 non-dyspeptic (control group. Questionnaire applied based on Rome III criteria. The patients underwent H2-lactulose breath test, considered positive when: H2 peak exceeding 20 ppm, in relation to fasting, or two peaks exceeding 10 ppm sustained until 60 minutes. RESULTS: Of the 23 dyspeptic patients, 13 (56.5% obtained positive results for SIBO trough the H2-lactulose breath test. On control group, SIBO was not observed. The association between the dyspeptic group and the control group regarding SIBO was statistically significant, with P = 0.0052. In the group of dyspeptic patients, 12 (52.2% were using proton pump inhibitor; of these 9 (75% were positive for SIBO. In the control group, none of the 11 patients used proton pump inhibitors and SIBO was not observed. The association of the dyspeptic group using proton pump inhibitor that were positive for SIBO and the control group was statistically significant, with P = 0.0011. CONCLUSION: It was found that, patients with functional dyspepsia presented SIBO, when they underwent to H2-lactulose breath test, compared to the non-dyspeptic. In addition, it was observed a higher prevalence of SIBO in dyspeptic patients that were using proton pump inhibitors, compared to control group.CONTEXTO: A dispepsia funcional é uma afec

  3. Swimming in air-breathing fishes.

    Science.gov (United States)

    Lefevre, S; Domenici, P; McKenzie, D J

    2014-03-01

    Fishes with bimodal respiration differ in the extent of their reliance on air breathing to support aerobic metabolism, which is reflected in their lifestyles and ecologies. Many freshwater species undertake seasonal and reproductive migrations that presumably involve sustained aerobic exercise. In the six species studied to date, aerobic exercise in swim flumes stimulated air-breathing behaviour, and there is evidence that surfacing frequency and oxygen uptake from air show an exponential increase with increasing swimming speed. In some species, this was associated with an increase in the proportion of aerobic metabolism met by aerial respiration, while in others the proportion remained relatively constant. The ecological significance of anaerobic swimming activities, such as sprinting and fast-start manoeuvres during predator-prey interactions, has been little studied in air-breathing fishes. Some species practise air breathing during recovery itself, while others prefer to increase aquatic respiration, possibly to promote branchial ion exchange to restore acid-base balance, and to remain quiescent and avoid being visible to predators. Overall, the diversity of air-breathing fishes is reflected in their swimming physiology as well, and further research is needed to increase the understanding of the differences and the mechanisms through which air breathing is controlled and used during exercise.

  4. Sleep disordered breathing in facioscapulohumeral muscular dystrophy.

    Science.gov (United States)

    Della Marca, Giacomo; Frusciante, Roberto; Dittoni, Serena; Vollono, Catello; Buccarella, Cristina; Iannaccone, Elisabetta; Rossi, Monica; Scarano, Emanuele; Pirronti, Tommaso; Cianfoni, Alessandro; Mazza, Salvatore; Tonali, Pietro A; Ricci, Enzo

    2009-10-15

    Facioscapulohumeral muscular dystrophy (FSHD) is one of the most frequent forms of muscular dystrophy. The aims of this study were: 1) to evaluate the prevalence of sleep disordered breathing (SDB) in patients with FSHD; 2) to define the sleep-related respiratory patterns in FSHD patients with SDB; and 3) to find the clinical predictors of SDB. Fifty-one consecutive FSHD patients were enrolled, 23 women, mean age 45.7+/-12.3 years (range: 26-72). The diagnosis of FSHD was confirmed by genetic tests. All patients underwent medical and neurological evaluations, subjective evaluation of sleep and full-night laboratory-based polysomnography. Twenty patients presented SDB: 13 presented obstructive apneas, four presented REM related oxygen desaturations and three showed a mixed pattern. Three patients needed positive airways pressure. SDB was not related to the severity of the disease. Body mass index, neck circumference and daytime sleepiness did not allow prediction of SDB. In conclusion, the results suggest a high prevalence of SDB in patients with FSHD. The presence of SDB does not depend on the clinical severity of the disease. SDB is often asymptomatic, and no clinical or physical measure can reliably predict its occurrence. A screening of SDB should be included in the clinical assessment of FSHD.

  5. Development of an Exhaled Breath Monitoring System with Semiconductive Gas Sensors, a Gas Condenser Unit, and Gas Chromatograph Columns

    Directory of Open Access Journals (Sweden)

    Toshio Itoh

    2016-11-01

    Full Text Available Various volatile organic compounds (VOCs in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls, and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls. The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis.

  6. Development of an Exhaled Breath Monitoring System with Semiconductive Gas Sensors, a Gas Condenser Unit, and Gas Chromatograph Columns.

    Science.gov (United States)

    Itoh, Toshio; Miwa, Toshio; Tsuruta, Akihiro; Akamatsu, Takafumi; Izu, Noriya; Shin, Woosuck; Park, Jangchul; Hida, Toyoaki; Eda, Takeshi; Setoguchi, Yasuhiro

    2016-11-10

    Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis.

  7. Lung Function Measurement with Multiple-Breath-Helium Washout System

    CERN Document Server

    Wang, Jau-Yi; Owers-Bradley, John; Mellor, Chris

    2011-01-01

    Multiple-breath-washout (MBW) measurements are regarded as a sensitive technique which can reflect the ventilation inhomogeneity of respiratory airways. Typically nitrogen is used as the tracer gas and is washed out by pure oxygen in multi-breath-nitrogen (MBNW) washout tests. In this work, instead of using nitrogen, helium is used as the tracer gas and a multiple-helium-breath-washout (MBHW) system has been developed for the lung function study. A commercial quartz tuning fork with a resonance frequency of 32768 Hz has been used for detecting the change of the respiratory gas density. The resonance frequency of the tuning fork decreases linearly with increasing density of the surrounding gas. Knowing the CO2 concentration from the infrared carbon dioxide detector, the helium concentration can be determined. Results from 12 volunteers (3 mild asthmatics, 2 smokers, 1 with asthma history, 1 with COPD history, 5 normal) have shown that mild asthmatics have higher ventilation inhomogeneity in either conducting o...

  8. Boundary oscillations at Geotail: Windsock, breathing, and wrenching

    Science.gov (United States)

    Shodhan, S.; Siscoe, G. L.; Frank, L. A.; Ackerson, K. L.; Paterson, W. R.

    1996-02-01

    On March 18-19, 1993, when Geotail was beyond 150 RE down the tail, for about 30 hours it frequently transited between magnetosheath-like plasma and lobe-like plasma. The transitions take the form of smooth variation by about a factor of 10 in both density and speed. Some of the transitions are distinctly asymmetric with a fast rise to sheath-like values and a slow decline to lobe-like values. We have suggested that these transitional regions are the plasma mantle, but this raises the question of why the mantle crossed Geotail many times in 30 hours. Three possible causes are flapping of the tail in response to solar wind flow changes (the windsock mechanism), intrinsic expansions and contractions of the tail boundary, perhaps in response to substorm phases (the breathing mechanism), and an IMF-squeezed elliptical tail cross section changing its orientation to follow the IMF (the wrenching mechanism). We test these possibilities here by examining simultaneous solar wind velocity and magnetic field data from IMP 8. For the cases studied, both the windsock and the breathing mechanisms appear to contribute to the motions that cause the transitions, whereas the wrenching mechanism seems less effective. Breathing dominates on a timescale of tens of minutes, and windsock dominates on a scale of hours. Since the windsock mechanism is unavoidable, the important finding here is that the breathing mechanism appears also to operate. We use the windsock variation to estimate the thickness of the mantle at Geotail's position and find that the density drops by a factor of 10 in 9 RE. We model the mantle as a one-dimensional slow-mode expansion fan and use the model to predict the change in plasma parameters that occurs from the outer edge of the mantle to its inner edge. A comparison of the predicted profile with the observed profile shows that the model simulates the observed changes reasonably well.

  9. INFLUENCE OF MUSIC THERAPY AND BREATHING EXERCISES ON ANXIETY IN POST-OPERATIVE CARDIAC DISEASED INDIVIDUALS

    Directory of Open Access Journals (Sweden)

    C. Janardan

    2016-02-01

    Full Text Available Background: Asian Indians have a higher operative and overall increased mortality following coronary bypass surgery. They also have higher rates of post operative complications and repeat surgeries. Apart from physiological complications like post-operative pain, atelectasis, deep vein thrombosis, the psychological disorders are like anxiety and stress also predominantly play a major role in the morbidity of the post-surgical conditions. The aim of study is to know the influence of music therapy and breathing exercises on post-surgical cardiac diseased individuals. To evaluate the influence of music therapy and breathing exercises on physiological parameters(BP,HR,RR in post surgical cardiac diseased individuals by using electro cardio monitor and state-trait anxiety scale. Methods: Subjects were randomly divided into two groups. Experimental group, where the subjects received music therapy and breathing exercises. Control group, where the subjects received breathing exercises. All the participants were assessed with STAI scale and physiological parameters like blood pressure, heart rate and respiration rate for both groups before and after the treatment. Paired sample t-test was used to compare the STAI scale and physiological parameters within the groups. Result: Results showed a significant improvement in both the groups but, more improvement was seen in experimental group compared to control group. Conclusion: Results suggested that music therapy and breathing exercises influences more effective than breathing exercises alone.

  10. Detection of response to command using voluntary control of breathing in disorders of consciousness

    Science.gov (United States)

    Charland-Verville, Vanessa; Lesenfants, Damien; Sela, Lee; Noirhomme, Quentin; Ziegler, Erik; Chatelle, Camille; Plotkin, Anton; Sobel, Noam; Laureys, Steven

    2014-01-01

    Background: Detecting signs of consciousness in patients in a vegetative state/unresponsive wakefulness syndrome (UWS/VS) or minimally conscious state (MCS) is known to be very challenging. Plotkin et al. (2010) recently showed the possibility of using a breathing-controlled communication device in patients with locked in syndrome. We here aim to test a breathing-based “sniff controller” that could be used as an alternative diagnostic tool to evaluate response to command in severely brain damaged patients with chronic disorders of consciousness (DOC). Methods: Twenty-five DOC patients were included. Patients’ resting breathing-amplitude was measured during a 5 min resting condition. Next, they were instructed to end the presentation of a music sequence by sniffing vigorously. An automated detection of changes in breathing amplitude (i.e., >1.5 SD of resting) ended the music and hence provided positive feedback to the patient. Results: None of the 11 UWS/VS patients showed a sniff-based response to command. One out of 14 patients with MCS was able to willfully modulate his breathing pattern to answer the command on 16/19 trials (accuracy 84%). Interestingly, this patient failed to show any other motor response to command. Discussion: We here illustrate the possible interest of using breathing-dependent response to command in the detection of residual cognition in patients with DOC after severe brain injury. PMID:25566035

  11. Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening.

    Directory of Open Access Journals (Sweden)

    Michael Phillips

    Full Text Available Breath volatile organic compounds (VOCs have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening.Model-building phase (unblinded: Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation: We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively. The algorithm predicted discriminant function (DF values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B. Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening.Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88. In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel.Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort

  12. Ecological sounds affect breath duration more than artificial sounds.

    Science.gov (United States)

    Murgia, Mauro; Santoro, Ilaria; Tamburini, Giorgia; Prpic, Valter; Sors, Fabrizio; Galmonte, Alessandra; Agostini, Tiziano

    2016-01-01

    Previous research has demonstrated that auditory rhythms affect both movement and physiological functions. We hypothesized that the ecological sounds of human breathing can affect breathing more than artificial sounds of breathing, varying in tones for inspiration and expiration. To address this question, we monitored the breath duration of participants exposed to three conditions: (a) ecological sounds of breathing, (b) artificial sounds of breathing having equal temporal features as the ecological sounds, (c) no sounds (control). We found that participants' breath duration variability was reduced in the ecological sound condition, more than in the artificial sound condition. We suggest that ecological sounds captured the timing of breathing better than artificial sounds, guiding as a consequence participants' breathing. We interpreted our results according to the Theory of Event Coding, providing further support to its validity, and suggesting its possible extension in the domain of physiological functions which are both consciously and unconsciously controlled.

  13. Cheyne-Stokes respiration: hypoxia plus a deep breath that interrupts hypoxic drive, initiating cyclic breathing.

    Science.gov (United States)

    Guntheroth, Warren G

    2011-11-01

    hypoxic drive, and the cycle of C-SR continues until the next large breath. This novel theory, that a pulse of oxygen interrupts hypoxic drive to cause the initiating apnea of C-SR, is compatible with the known causes of C-SR: onset of sleep, mild hypoxia with congestive heart failure, and neurologic disorders. It is also compatible with factors known to abolish C-SR: waking, oxygen supplementation, and drugs that increase alertness such as caffeine. Testing of the hypothesis would require beat by beat recording of respiration, and arterial oxygen with a response time fast enough to demonstrate the rapid suppression of hypoxic drive. Alternatively, using a different theoretical approach such as limit-cycle oscillators instead of control theory.

  14. Sudarshan kriya yoga: Breathing for health

    Directory of Open Access Journals (Sweden)

    Sameer A Zope

    2013-01-01

    Full Text Available Breathing techniques are regularly recommended for relaxation, stress management, control of psychophysiological states, and to improve organ function. Yogic breathing, defined as a manipulation of breath movement, has been shown to positively affect immune function, autonomic nervous system imbalances, and psychological or stress-related disorders. The aim of this study was to assess and provide a comprehensive review of the physiological mechanisms, the mind-body connection, and the benefits of Sudarshan Kriya Yoga (SKY in a wide range of clinical conditions. Various online databases searched were Medline, Psychinfo, EMBASE, and Google Scholar. All the results were carefully screened and articles on SKY were selected. The references from these articles were checked to find any other potentially relevant articles. SKY, a unique yogic breathing practice, involves several types of cyclical breathing patterns, ranging from slow and calming to rapid and stimulating. There is mounting evidence to suggest that SKY can be a beneficial, low-risk, low-cost adjunct to the treatment of stress, anxiety, post-traumatic stress disorder, depression, stress-related medical illnesses, substance abuse, and rehabilitation of criminal offenders.

  15. Pulse Ejection Presentation System Synchronized with Breathing

    Science.gov (United States)

    Kadowaki, Ami; Sato, Junta; Ohtsu, Kaori; Bannai, Yuichi; Okada, Kenichi

    Trials on transmission of olfactory information together with audio/visual information are currently being conducted in the field of multimedia. However, continuous emission of scents in high concentration creates problems of human adaptation and remnant odors in air. To overcome such problems we developed an olfactory display in conjunction with Canon Inc. This display has high emission control in the ink-jet so that it can provide stable pulse emission of scents. Humans catch a scent when they breathe in and inhale smell molecules in air. Therefore, it is important that the timing of scent presentation is synchronized with human breathing. We also developed a breath sensor which detects human inspiration. In this study, we combined the olfactory display with the breath sensor to make a pulse ejection presentation system synchronized the breath. The experimental evaluation showed that the system had more than 90 percent of detection rate. Another evaluation was held at KEIO TECHNO-MALL 2007. From questionnaire results of the participants, we found that the system made the user feel continuous sense of smell avoiding adaptation. It is expected that our system enables olfactory information to be synchronized with audio/visual information in arbitrary duration at any time.

  16. 呼气试验在胃肠道疾病中的临床应用及价值%Clinical application and significance of breath test in the treatment of gastric and intestinal diseases

    Institute of Scientific and Technical Information of China (English)

    辛桂霞; 丁金秀

    2009-01-01

    早在1784年,Antoine Laurent Lavoisier发现动物和人类能通过呼气排出CO:,首次证明食物能在体内“燃烧”,从此开始了现代意义的呼气试验。20世纪中叶,出现了标记化合物的呼气试验用于消化系疾病的诊断;1961年,Nelsen首次建立了呼气氢试验(breath hydrogen test,BHT),1984年起在我国开展应用,近年来因试验仪器的改进,如微量氢气测定仪的问世,使该试验的临床应用得到进一步发展。由于该方法简便、准确、无创、迅速,现已广泛用于胃肠疾病的诊断;至20世纪80年代末,UBT诊断幽门螺杆菌的巨大成功引起众多学者对呼气试验的重视。本文将近年来有关呼气试验在胃肠病诊断中的应用文献作一综述。

  17. Technologies for Clinical Diagnosis Using Expired Human Breath Analysis

    Directory of Open Access Journals (Sweden)

    Thalakkotur Lazar Mathew

    2015-02-01

    Full Text Available This review elucidates the technologies in the field of exhaled breath analysis. Exhaled breath gas analysis offers an inexpensive, noninvasive and rapid method for detecting a large number of compounds under various conditions for health and disease states. There are various techniques to analyze some exhaled breath gases, including spectrometry, gas chromatography and spectroscopy. This review places emphasis on some of the critical biomarkers present in exhaled human breath, and its related effects. Additionally, various medical monitoring techniques used for breath analysis have been discussed. It also includes the current scenario of breath analysis with nanotechnology-oriented techniques

  18. Decompression sickness following breath-hold diving.

    Science.gov (United States)

    Schipke, J D; Gams, E; Kallweit, Oliver

    2006-01-01

    Despite convincing evidence of a relationship between breath-hold diving and decompression sickness (DCS), the causal connection is only slowly being accepted. Only the more recent textbooks have acknowledged the risks of repetitive breath-hold diving. We compare four groups of breath-hold divers: (1) Japanese and Korean amas and other divers from the Pacific area, (2) instructors at naval training facilities, (3) spear fishers, and (4) free-dive athletes. While the number of amas is likely decreasing, and Scandinavian Navy training facilities recorded only a few accidents, the number of spear fishers suffering accidents is on the rise, in particular during championships or using scooters. Finally, national and international associations (e.g., International Association of Free Drives [IAFD] or Association Internationale pour Le Developpment De L'Apnee [AIDA]) promote free-diving championships including deep diving categories such as constant weight, variable weight, and no limit. A number of free-diving athletes, training for or participating in competitions, are increasingly accident prone as the world record is presently set at a depth of 171 m. This review presents data found after searching Medline and ISI Web of Science and using appropriate Internet search engines (e.g., Google). We report some 90 cases in which DCS occurred after repetitive breath-hold dives. Even today, the risk of suffering from DCS after repetitive breath-hold diving is often not acknowledged. We strongly suggest that breath-hold divers and their advisors and physicians be made aware of the possibility of DCS and of the appropriate therapeutic measures to be taken when DCS is suspected. Because the risk of suffering from DCS increases depending on depth, bottom time, rate of ascent, and duration of surface intervals, some approaches to assess the risks are presented. Regrettably, none of these approaches is widely accepted. We propose therefore the development of easily manageable

  19. Electrospray ionization of volatiles in breath

    Science.gov (United States)

    Martínez-Lozano, P.; de La Mora, J. Fernández

    2007-08-01

    Recent work by Zenobi and colleagues [H. Chen, A. Wortmann, W. Zhang, R. Zenobi, Angew. Chem. Int. Ed. 46 (2007) 580] reports that human breath charged by contact with an electrospray (ES) cloud yields many mass peaks of species such as urea, glucose, and other ions, some with molecular weights above 1000 Da. All these species are presumed to be involatile, and to originate from breath aerosols by so-called extractive electrospray ionization EESI [H. Chen, A. Venter, R.G. Cooks, Chem. Commun. (2006) 2042]. However, prior work by Fenn and colleagues [C.M. Whitehouse, F. Levin, C.K. Meng, J.B. Fenn, Proceedings of the 34th ASMS Conference on Mass Spectrometry and Allied Topics, Denver, 1986 p. 507; S. Fuerstenau, P. Kiselev, J.B. Fenn, Proceedings of the 47th ASMS Conference on Mass Spectrometry, 1999, Dallas, TX, 1999] and by Hill and colleagues [C. Wu, W.F. Siems, H.H. Hill Jr., Anal. Chem. 72 (2000) 396] have reported the ability of electrospray drops to ionize a variety of low vapor pressure substances directly from the gas phase, without an apparent need for the vapor to be brought into the charging ES in aerosol form. The Ph.D. Thesis of Martínez-Lozano [P. Martínez-Lozano Sinués, Ph.D. Thesis, Department of Thermal and Fluid Engineering, University Carlos III of Madrid; April 5, 2006 (in Spanish); http://hdl.handle.net/10016/655] had also previously argued that the numerous human breath species observed via a similar ES ionization approach were in fact ionized directly from the vapor. Here, we observe that passage of the breath stream through a submicron filter does not eliminate the majority of the breath vapors seen in the absence of the filter. We conclude that direct vapor charging is the leading mechanism in breath ionization by electrospray drops, though aerosol ionization may also play a role.

  20. Medication effects on sleep and breathing.

    Science.gov (United States)

    Seda, Gilbert; Tsai, Sheila; Lee-Chiong, Teofilo

    2014-09-01

    Sleep respiration is regulated by circadian, endocrine, mechanical and chemical factors, and characterized by diminished ventilatory drive and changes in Pao2 and Paco2 thresholds. Hypoxemia and hypercapnia are more pronounced during rapid eye movement. Breathing is influenced by sleep stage and airway muscle tone. Patient factors include medical comorbidities and body habitus. Medications partially improve obstructive sleep apnea and stabilize periodic breathing at altitude. Potential adverse consequences of medications include precipitation or worsening of disorders. Risk factors for adverse medication effects include aging, medical disorders, and use of multiple medications that affect respiration.

  1. Comparison of two devices and two breathing patterns for exhaled breath condensate sampling.

    Directory of Open Access Journals (Sweden)

    Eva-Maria Hüttmann

    Full Text Available Analysis of exhaled breath condensate (EBC is a noninvasive method to access the epithelial lining fluid of the lungs. Due to standardization problems the method has not entered clinical practice. The aim of the study was to assess the comparability for two commercially available devices in healthy controls. In addition, we assessed different breathing patterns in healthy controls with protein markers to analyze the source of the EBC.EBC was collected from ten subjects using the RTube and ECoScreen Turbo in a randomized crossover design, twice with every device--once in tidal breathing and once in hyperventilation. EBC conductivity, pH, surfactant protein A, Clara cell secretory protein and total protein were assessed. Bland-Altman plots were constructed to display the influence of different devices or breathing patterns and the intra-class correlation coefficient (ICC was calculated. The volatile organic compound profile was measured using the electronic nose Cyranose 320. For the analysis of these data, the linear discriminant analysis, the Mahalanobis distances and the cross-validation values (CVV were calculated.Neither the device nor the breathing pattern significantly altered EBC pH or conductivity. ICCs ranged from 0.61 to 0.92 demonstrating moderate to very good agreement. Protein measurements were greatly influenced by breathing pattern, the device used, and the way in which the results were reported. The electronic nose could distinguish between different breathing patterns and devices, resulting in Mahalanobis distances greater than 2 and CVVs ranging from 64% to 87%.EBC pH and (to a lesser extent EBC conductivity are stable parameters that are not influenced by either the device or the breathing patterns. Protein measurements remain uncertain due to problems of standardization. We conclude that the influence of the breathing maneuver translates into the necessity to keep the volume of ventilated air constant in further studies.

  2. High Frequency Yoga Breathing: A Review of Nervous System Effects and Adjunctive Therapeutic and Premeditation Potential

    Directory of Open Access Journals (Sweden)

    Anna Andaházy

    2016-05-01

    Full Text Available High frequency yoga breathing (HFYB results in a shifting of the autonomic nervous system balance towards sympathetic nervous system dominance. In an effort to more fully understand the complex effects of this form of yogic breath-work, tests are being conducted on practitioners’ physiological and neurological response processes. Studies on heart rate variability (HRV indicating cardiac autonomic control have shown a resulting reduction of vagal activity following HFYB, leading to passive sympathetic dominance without overt excitation or exhaustion. Comparative cognitive tests taken after the practice have shown that HFYB results in reduced auditory and visual reaction times, and a decrease in optical illusion. The vigilant, wakeful, yet relaxed state induced by HFYB has been associated with improvements in attention, memory, sensorimotor performance, and mood. As breathing bridges conscious and unconscious functions, the potential role of HFYB as an adjunctive therapeutic intervention as well as its possible application in preparation for meditation is considered.

  3. Breathing adapted radiotherapy for breast cancer: comparison of free breathing gating with the breath-hold technique

    DEFF Research Database (Denmark)

    Korreman, Stine Sofia; Pedersen, Anders N; Nøttrup, Trine Jakobi;

    2005-01-01

    -hold (EBH). The Varian Real-time Position Management system (RPM) was used to monitor respiratory movement and to gate the scanner. For each breathing phase, a population based internal margin (IM) was estimated based on average chest wall excursion, and incorporated into an individually optimised three...

  4. In vivo proton MRS of normal pancreas metabolites during breath-holding and free-breathing

    Energy Technology Data Exchange (ETDEWEB)

    Su, T.-H. [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong-An Road, Beijing (China); Jin, E.-H., E-mail: erhujin1@hotmail.com [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong-An Road, Beijing (China); Shen, H. [GE China Company Ltd, Healthcare, General Electric Company, Beijing (China); Zhang, Y.; He, W. [Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong-An Road, Beijing (China)

    2012-07-15

    Aim: To characterize normal pancreas metabolites using in vivo proton magnetic resonance spectroscopy ({sup 1}H MRS) at 3 T under conditions of breath-holding and free-breathing. Materials and methods: The pancreases of 32 healthy volunteers were examined using {sup 1}H MRS during breath-holding and free-breathing acquisitions in a single-voxel point-resolved selective spectroscopy sequence (PRESS) technique using a 3 T MRI system. Resonances were compared between paired spectra of the two breathing modes. Furthermore, correlations between lipid (Lip) content and age, body-mass index (BMI), as well as choline (Cho) peak visibility of the normal pancreas were analysed during breath-holding. Results: Twenty-nine pairs of spectra were successfully obtained showing three major resonances, Lip, Cho, cholesterol and the unsaturated parts of the olefinic region of fatty acids (Chol + Unsat). Breath-hold spectra were generally better, with higher signal-to-noise ratios (SNR; Z=-2.646, p = 0.008) and Cho peak visible status (Z=-2.449, p = 0.014). Correlations were significant between spectra acquired by the two breathing modes, especially for Lip height, Lip area, and the area of other peaks at 1.9-4.1 ppm. However, the Lip resonance was significantly different between the spectra of the two breathing modes (p < 0.05). In the breath-holding spectra, there were significant positive correlations between Lip peak height, area, and age (r = 0.491 and 0.521, p = 0.007 and 0.004), but not between Lip peak area and BMI. There was no statistical difference in Cho resonances between males and females. The Lip peak height and area were significantly higher in the Cho peak invisible group than in the Cho peak visible group (t = 2.661 and 2.353, p = 0.030 and 0.043). Conclusion: In vivo{sup 1}H MRS of the normal pancreas at 3 T is technically feasible and can characterize several metabolites. {sup 1}H MRS during breath-holding acquisition is superior to that during free-breathing

  5. Flute ``breath support'' perception and its acoustical correlates

    Science.gov (United States)

    Cossette, Isabelle A.; Sabourin, Patrick

    2001-05-01

    Music educators and performers commonly refer to ``breath support'' in flute playing, yet the term ``support'' is neither well-defined nor consistently used. Different breathing strategies used by professional flautists who were instructed to play with and without support were previously identified by the authors. In the current study, 14 musical excerpts with and without support were recorded by five professional flautists. Eleven professional flautists listened to the recordings in a random order and ranked (1 to 6) how much of the following sound qualities they judged to be in each example: support, intonation, control and musical expressiveness. Answers to the test showed that musical expressiveness was associated more closely with the supported excerpts than the answers about support itself. The ratings for each sound quality were highly intercorrelated. Acoustical parameters were analyzed (frequency and centroid variation within each note) and compared with the results of the perception test in order to better understand how the acoustical and psychological variables were related. The acoustical analysis of the central part of the notes did not show evident correlation with the answers of the perception test. [Work funded by the Social Sciences and Humanities Research Council of Canada.

  6. Acute effects of deep breathing for a short duration (2-10 minutes) on pulmonary functions in healthy young volunteers.

    Science.gov (United States)

    Sivakumar, G; Prabhu, Krishnamoorthi; Baliga, Rekha; Pai, M Kirtana; Manjunatha, S

    2011-01-01

    Breathing is the most vital function for maintenance of life. Slow and deep breathing is an integral part of Pranayama and it reduces dead space ventilation and renews air throughout the lungs. The reported beneficial effects of deep breathing as a part of either long term or short term practice of Pranayama are well documented. However our knowledge about the effects of a few minutes' of deep breathing on human ventilatory parameters is poor. In the present study, we examined the relationship between exposure to short duration of deep breathing and performance on pulmonary function tests before and after the deep breathing. The study was conducted in a homogenous group of 12 volunteers containing 4 females and 8 males who were well trained in pulmonary function testing (PFT) before the start of the study. The volunteers performed deep breathing (DB) exercise for 2, 5 and 10 minutes at the rate of 6 breaths per minute under guidance, and the duration of DB exercise for that day was randomly selected for each group. PFT was done before and after the DB exercise. There was a significant (P vital capacity (VC) after 2 and 5 minutes' DB exercise and a consistent improvement in tidal volume (TV) and minute ventilation (MV) after the DB exercise in all the three groups, though it wasn't statistically significant. There was a significant (P vital capacity (FVC) after 2 minutes' of DB exercise and a consistent increase in all the three groups in forced inspiratory vital capacity (FIVC) and peak inspiratory flow rate (PIFR), though this increase was not statistically significant. This shows that deep breathing exercise, even for a few minutes' duration is beneficial for the lung functions.

  7. 42 CFR 84.195 - Breathing tubes; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... Cartridge Respirators § 84.195 Breathing tubes; minimum requirements. Flexible breathing tubes used in conjunction with respirators shall be designed and constructed to prevent: (a) Restriction of free...

  8. 42 CFR 84.132 - Breathing tubes; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... Respirators § 84.132 Breathing tubes; minimum requirements. Flexible breathing tubes used in conjunction with supplied-air respirators shall be designed and constructed to prevent: (a) Restriction of free...

  9. Apolo Ohno: Breathing Easier | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... please turn Javascript on. Feature: Breathing Easier Apolo Ohno: Breathing Easier Past Issues / Fall 2013 Table of ... skating. What does the future hold for Apolo Ohno? Even though I'm no longer skating competitively, ...

  10. Oxygen pre-breathing decreases dysbaric diseases in UW sheep undergoing hyperbaric exposure.

    Science.gov (United States)

    Sobakin, A S; Wilson, M A; Lehner, C E; Dueland, R T; Gendron-Fitzpatrick, A P

    2008-01-01

    Prolonged exposure of humans and animals to increased pressure as in a disabled submarine (DISSUB) can saturate the body's tissues with dissolved N2 as compressed air is breathed. Decompression-induced bubble formation in the long bone marrow cavity may lead to a bone compartment syndrome resulting in bone ischemia and necrosis. We tested oxygen pre-breathing prior to decompression in sheep to assess the effect upon dysbaric osteonecrosis (DON) induction in a DISSUB simulation experiment. A total of sixteen adult female sheep were used throughout the experiment. Four sheep were used as controls without oxygen pre-breathing. All sheep (99 +/- 14 kg SD) underwent dry chamber air exposure at 60 fsw (2.79 atm abs) (.2827 MPa) for 24 h followed by oxygen (88-92%) pre-breathing (15-min, 1-h, and 2-h and air for control) before "dropout" decompression at 30 fsw/min (0.91 atm/min). 99mTc-methylene diphosphonate (MDP) bone scans of the distal (radii and tibiae) long bones were used to detect "hot spots" of remodeling suggestive of DON lesions. Alizarin complexone fluorochrome was injected to visualize sites of metabolic activity indicating DON repair of both the proximal and distal long bones (radii, tibiae, femora, and humeri). Our findings showed that the amount of alizarin complexone deposition and bone scan uptake was greater in sheep with shorter oxygen pre-breathing times than those undergoing longer pre-breathing dives (p = 0.0056 and p = 0.001, for one and two hour pre-breathes respectively). Proximal limb bones (femur, humerus) displayed less alizarin complexone deposition than the distal radius and tibia (p < 0.0001).

  11. Elevated carbon monoxide in the exhaled breath of mice during a systemic bacterial infection.

    Directory of Open Access Journals (Sweden)

    Alan G Barbour

    Full Text Available Blood is the specimen of choice for most laboratory tests for diagnosis and disease monitoring. Sampling exhaled breath is a noninvasive alternative to phlebotomy and has the potential for real-time monitoring at the bedside. Improved instrumentation has advanced breath analysis for several gaseous compounds from humans. However, application to small animal models of diseases and physiology has been limited. To extend breath analysis to mice, we crafted a means for collecting nose-only breath samples from groups and individual animals who were awake. Samples were subjected to gas chromatography and mass spectrometry procedures developed for highly sensitive analysis of trace volatile organic compounds (VOCs in the atmosphere. We evaluated the system with experimental systemic infections of severe combined immunodeficiency Mus musculus with the bacterium Borrelia hermsii. Infected mice developed bacterial densities of ∼10(7 per ml of blood by day 4 or 5 and in comparison to uninfected controls had hepatosplenomegaly and elevations of both inflammatory and anti-inflammatory cytokines. While 12 samples from individual infected mice on days 4 and 5 and 6 samples from uninfected mice did not significantly differ for 72 different VOCs, carbon monoxide (CO was elevated in samples from infected mice, with a mean (95% confidence limits effect size of 4.2 (2.8-5.6, when differences in CO2 in the breath were taken into account. Normalized CO values declined to the uninfected range after one day of treatment with the antibiotic ceftriaxone. Strongly correlated with CO in the breath were levels of heme oxygenase-1 protein in serum and HMOX1 transcripts in whole blood. These results (i provide further evidence of the informativeness of CO concentration in the exhaled breath during systemic infection and inflammation, and (ii encourage evaluation of this noninvasive analytic approach in other various other rodent models of infection and for utility in

  12. The cerebral cost of breathing: an FMRI case-study in congenital central hypoventilation syndrome.

    Directory of Open Access Journals (Sweden)

    Mike Sharman

    Full Text Available Certain motor activities--like walking or breathing--present the interesting property of proceeding either automatically or under voluntary control. In the case of breathing, brainstem structures located in the medulla are in charge of the automatic mode, whereas cortico-subcortical brain networks--including various frontal lobe areas--subtend the voluntary mode. We speculated that the involvement of cortical activity during voluntary breathing could impact both on the "resting state" pattern of cortical-subcortical connectivity, and on the recruitment of executive functions mediated by the frontal lobe. In order to test this prediction we explored a patient suffering from central congenital hypoventilation syndrome (CCHS, a very rare developmental condition secondary to brainstem dysfunction. Typically, CCHS patients demonstrate efficient cortically-controlled breathing while awake, but require mechanically-assisted ventilation during sleep to overcome the inability of brainstem structures to mediate automatic breathing. We used simultaneous EEG-fMRI recordings to compare patterns of brain activity between these two types of ventilation during wakefulness. As compared with spontaneous breathing (SB, mechanical ventilation (MV restored the default mode network (DMN associated with self-consciousness, mind-wandering, creativity and introspection in healthy subjects. SB on the other hand resulted in a specific increase of functional connectivity between brainstem and frontal lobe. Behaviorally, the patient was more efficient in cognitive tasks requiring executive control during MV than during SB, in agreement with her subjective reports in everyday life. Taken together our results provide insight into the cognitive and neural costs of spontaneous breathing in one CCHS patient, and suggest that MV during waking periods may free up frontal lobe resources, and make them available for cognitive recruitment. More generally, this study reveals how the

  13. Design and Evaluation of a Breath Analysis System for Occupational Exposure Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Soldat, Kelvin L.; Thrall, Karla D.

    2001-06-01

    Exposure assessment is an integral part of industrial hygiene and occupational health. To ensure the health and safety of workers, integrated industrial hygiene methodologies often include biological monitoring strategies. Exhaled breath is an ideal matrix for measuring volatile biomarkers, particularly since the non-invasive collection of breath may improve volunteer participation. A real-time, field-portable system was developed to analyze undiluted exhaled air from experimental animals and humans. The system combines (1) an ion-trap mass spectrometer capable of atmospheric sampling; (2) a breath interface for continual analysis of the exhaled breath stream; (3) chemical dosimeters that are analyzed in the field/workplace; and (4) physiologically based pharmacokinetic (PBPK) models to estimate total exposure and internal target tissue dosimetry. The intent of this development was to provide new instrumentation to evaluate volatile chemical exposures as part of a daily monitoring pro gram. For example, the system was designed to monitor a worker every time they enter and leave a work environment - a vast improvement over current 8-hr integrated monitoring strategies. To evaluate the system in actual work environments, field tests were conducted using volunteers providing exhaled breath samples before and after each specific job task. In these field studies, several volunteers had post-task breath levels higher than pre-task levels. Compared to the breath analysis findings, chemical dosimeters underpredicted exposures, particularly for longer sampling intervals where the volume of air sampled may have diluted exposures. The results of these field studies illustrate the utility of monitoring workers for exposures at numerous times throughout the day, particularly when job-specific tasks may indicate a potential for exposure.

  14. Measuring breath acetone for monitoring fat loss: Review

    OpenAIRE

    Anderson, Joseph C.

    2015-01-01

    Objective Endogenous acetone production is a by‐product of the fat metabolism process. Because of its small size, acetone appears in exhaled breath. Historically, endogenous acetone has been measured in exhaled breath to monitor ketosis in healthy and diabetic subjects. Recently, breath acetone concentration (BrAce) has been shown to correlate with the rate of fat loss in healthy individuals. In this review, the measurement of breath acetone in healthy subjects is evaluated for its utility in...

  15. Ineffective breathing pattern related to malnutrition.

    Science.gov (United States)

    Openbrier, D R; Covey, M

    1987-03-01

    This article has highlighted the problem of malnutrition in the stable COPD patient and the critically ill, hypercatabolic patient, and has reviewed resultant mechanisms which influence the alteration of breathing pattern. These complex patients present a challenge for the nurse. Table 1 briefly summarizes the manifestations of malnutrition, goals, interventions and expected outcomes of the nursing diagnosis, ineffective breathing pattern related to malnutrition. The goal of the interventions is to modify the cause (malnutrition) of the nursing diagnosis (altered breathing pattern). The success of the interventions will lead to the achievement of expected outcome As expected outcomes are achieved, relief of signs and symptoms related to the nursing diagnosis will occur. The nurse caring for the patient with actual or potential malnutrition must be knowledgeable about the physiology of malnutrition and effect on breathing pattern. It is essential that the nurse assess and provide appropriate nutritional support and evaluate progress toward expected outcomes. In the event that expected outcomes are not achieved, reassessment with modification of interventions is necessary. Nurses play a key role in the total health care delivery to these complex patients. Further study will strengthen the research base of nursing interventions.

  16. Multi-layered breathing architectural envelope

    DEFF Research Database (Denmark)

    Lund Larsen, Andreas; Foged, Isak Worre; Jensen, Rasmus Lund

    2014-01-01

    A multi layered breathing envelope is developed as a method of natural ventilation. The two main layers consist of mineral wool and air permeable concrete. The mineral wool works as a dynamic insulation and the permeable concrete as a heat recovery system with a high thermal mass for heat storage...

  17. Fast and accurate exhaled breath ammonia measurement.

    Science.gov (United States)

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A; Risby, Terence H

    2014-06-11

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations.

  18. Sleep-disordered breathing in acromegaly

    Directory of Open Access Journals (Sweden)

    L K Dzeranova

    2013-03-01

    Full Text Available Sleep-disordered breathing is higly prevalent in acromegaly, disturbing patients quality of life and increasing the risk of acute cardiovascular compications. Presented clinical case discusses key considerations for timely diagnosis of sleep apnea syndrome and treatment planning. The case of 41 y.o. woman with newly diagnosed acromegaly and concomitant sleep apnea is typical for this disease.

  19. Coordination of breathing with nonrespiratory activities.

    Science.gov (United States)

    Bartlett, Donald; Leiter, James C

    2012-04-01

    Many articles in this section of Comprehensive Physiology are concerned with the development and function of a central pattern generator (CPG) for the control of breathing in vertebrate animals. The action of the respiratory CPG is extensively modified by cortical and other descending influences as well as by feedback from peripheral sensory systems. The central nervous system also incorporates other CPGs, which orchestrate a wide variety of discrete and repetitive, voluntary and involuntary movements. The coordination of breathing with these other activities requires interaction and coordination between the respiratory CPG and those governing the nonrespiratory activities. Most of these interactions are complex and poorly understood. They seem to involve both conventional synaptic crosstalk between groups of neurons and fluid identity of neurons as belonging to one CPG or another: neurons that normally participate in breathing may be temporarily borrowed or hijacked by a competing or interrupting activity. This review explores the control of breathing as it is influenced by many activities that are generally considered to be nonrespiratory. The mechanistic detail varies greatly among topics, reflecting the wide variety of pertinent experiments.

  20. Chemical Analysis of Whale Breath Volatiles: A Case Study for Non-Invasive Field Health Diagnostics of Marine Mammals

    Directory of Open Access Journals (Sweden)

    Raquel Cumeras

    2014-09-01

    Full Text Available We explored the feasibility of collecting exhaled breath from a moribund gray whale (Eschrichtius robustus for potential non-invasive health monitoring of marine mammals. Biogenic volatile organic compound (VOC profiling is a relatively new field of research, in which the chemical composition of breath is used to non-invasively assess the health and physiological processes on-going within an animal or human. In this study, two telescopic sampling poles were designed and tested with the primary aim of collecting whale breath exhalations (WBEs. Once the WBEs were successfully collected, they were immediately transferred onto a stable matrix sorbent through a custom manifold system. A total of two large volume WBEs were successfully captured and pre-concentrated onto two Tenax®-TA traps (one exhalation per trap. The samples were then returned to the laboratory where they were analyzed using solid phase micro extraction (SPME and gas chromatography/mass spectrometry (GC/MS. A total of 70 chemicals were identified (58 positively identified in the whale breath samples. These chemicals were also matched against a database of VOCs found in humans, and 44% of chemicals found in the whale breath are also released by healthy humans. The exhaled gray whale breath showed a rich diversity of chemicals, indicating the analysis of whale breath exhalations is a promising new field of research.

  1. Oral Breathing Challenge in Participants with Vocal Attrition

    Science.gov (United States)

    Sivasankar, Mahalakshmi; Fisher, Kimberly V.

    2003-01-01

    Vocal folds undergo osmotic challenge by mouth breathing during singing, exercising, and loud speaking. Just 15 min of obligatory oral breathing, to dry the vocal folds, increases phonation threshold pressure (P[subscript th]) and expiratory vocal effort in healthy speakers (M. Sivasankar & K. Fisher, 2002). We questioned whether oral breathing is…

  2. Human respiratory deposition of particles during oronasal breathing

    Science.gov (United States)

    Swift, David L.; Proctor, Donald F.

    Deposition of particles in the tracheobronchial and pulmonary airways is computed as a function of particle size, correcting for deposition in the parallel nasal and oral airways with oronasal breathing. Thoracic deposition is lower at all sizes for oronasal breathing than for mouth breathing via tube, and is negligible for aerodynamic equivalent diameters of 10 μm or larger.

  3. 46 CFR 197.340 - Breathing gas supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing gas supply. 197.340 Section 197.340 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.340 Breathing gas supply. (a) A primary breathing gas supply for surface-supplied diving must be sufficient to support the following for...

  4. 46 CFR 197.312 - Breathing supply hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.312 Section 197.312 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.312 Breathing supply hoses. (a) Each breathing supply hose must— (1) Have a maximum working pressure that is equal to or exceeds— (i) The...

  5. 21 CFR 868.5330 - Breathing gas mixer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breathing gas mixer. 868.5330 Section 868.5330...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5330 Breathing gas mixer. (a) Identification. A breathing gas mixer is a device intended for use in conjunction with a respiratory...

  6. 21 CFR 868.5240 - Anesthesia breathing circuit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia breathing circuit. 868.5240 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5240 Anesthesia breathing circuit. (a) Identification. An anesthesia breathing circuit is a device that is intended to administer medical gases to...

  7. 42 CFR 84.115 - Breathing tubes; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing tubes; minimum requirements. 84.115 Section 84.115 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL... § 84.115 Breathing tubes; minimum requirements. Flexible breathing tubes used in conjunction with...

  8. 42 CFR 84.172 - Breathing tubes; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing tubes; minimum requirements. 84.172... Air-Purifying Particulate Respirators § 84.172 Breathing tubes; minimum requirements. Flexible breathing tubes used in conjunction with respirators shall be designed and constructed to prevent:...

  9. Effects of Inspired CO2 and Breathing Resistance on Neurocognitive and Postural Stability in U.S. Navy Divers

    Science.gov (United States)

    2015-08-01

    breathing systems which have varying levels of breathing resistance depending on the design and minute ventilation. Whereas some closed systems, such...Bera tests (p > 0.05). Pearson product -moment correlation coefficients were computed between symptoms and throughput scores for each subtest. A...Balance Board for the Assessment of Balance of Healthy Young Adults and the Elderly ," Journal of Physical Therapy Science, Vol. 10 (2013), pp. 1251-1253

  10. How to deal with morning bad breath: A randomized, crossover clinical trial

    Directory of Open Access Journals (Sweden)

    Jeronimo M Oliveira-Neto

    2013-01-01

    Full Text Available Context: The absence of a protocol for the treatment of halitosis has led us to compare mouthrinses with mechanical oral hygiene procedures for treating morning breath by employing a hand-held sulfide monitor. Aims: To compare the efficacy of five modalities of treatment for controlling morning halitosis in subjects with no dental or periodontal disease. Settings and Design: This is a five-period, randomized, crossover clinical trial. Materials and Methods: Twenty volunteers were randomly assigned to the trial. Testing involved the use of a conventional tongue scraper, a tongue scraper joined to the back of a toothbrush′s head, two mouthrinses (0.05% cetylpyridinium chloride and 0.12% chlorhexidine digluconate and a soft-bristled toothbrush and fluoride toothpaste for practicing oral hygiene. Statistical Analysis Used: Data analysis was performed using SPSS version 17 for Windows and NCSS 2007 software (P < 0.05. The products and the periods were compared with each other using the Friedman′s test. When significant differences (P < 0.05 were determined, the products and periods were compared in pairs by using the Wilcoxon′s test and by adjusting the original significance level (0.05 for multiple comparisons by using the Bonferroni′s method. Results: The toothbrush′s tongue scraper was able to significantly reduce bad breath for up to 2 h. Chlorhexidine reduced bad breath only at the end of the second hour, an effect that lasted for 3 h. Conclusions: Mechanical tongue cleaning was able to immediately reduce bad breath for a short period, whereas chlorhexidine and mechanical oral hygiene reduced bad breath for longer periods, achieving the best results against morning breath.

  11. A mind you can count on: validating breath counting as a behavioral measure of mindfulness

    Directory of Open Access Journals (Sweden)

    Daniel B Levinson

    2014-10-01

    Full Text Available Mindfulness practice of present moment awareness promises many benefits, but has eluded rigorous behavioral measurement. To date, research has relied on self-reported mindfulness or heterogeneous mindfulness trainings to infer skillful mindfulness practice and its effects. In four independent studies with over 400 total participants, we present the first construct validation of a behavioral measure of mindfulness, breath counting. We found it was reliable, correlated with self-reported mindfulness, differentiated long-term meditators from age-matched controls, and was distinct from sustained attention and working memory measures. In addition, we employed breath counting to test the nomological network of mindfulness. As theorized, we found skill in breath counting associated with more meta-awareness, less mind wandering, better mood, and greater nonattachment (i.e. less attentional capture by distractors formerly paired with reward. We also found in a randomized online training study that 4 weeks of breath counting training improved mindfulness and decreased mind wandering relative to working memory training and no training controls. Together, these findings provide the first evidence for breath counting as a behavioral measure of mindfulness.

  12. Detection of Torque Teno Virus DNA in Exhaled Breath by Polymerase Chain Reaction

    Directory of Open Access Journals (Sweden)

    Kawanishi,Satoshi

    2012-10-01

    Full Text Available To determine whether exhaled breath contains Torque teno virus (TTV or not, we tested exhaled breath condensate (EBC samples by semi-nested PCR assay. We detected TTV DNA in 35% (7/20 of EBC samples collected from the mouth of one of the authors, demonstrating that TTV DNA is excreted in exhaled breath with moderate frequency. TTV DNA was detected also in oral EBC samples from 4 of 6 other authors, indicating that TTV DNA excretion in exhaled breath is not an exception but rather a common phenomenon. Furthermore, the same assay could amplify TTV DNA from room air condensate (RAC samples collected at distances of 20 and 40cm from a human face with 40 (8/20 and 35% (7/20 positive rates, respectively. TTV transmission has been reported to occur during infancy. These distances seem equivalent to that between an infant and its household members while caring for the infant. Taken together, it seems that exhaled breath is one of the possible transmission routes of TTV. We also detected TTV DNA in 25% (10/40 of RAC samples collected at a distance of more than 180cm from any human face, suggesting the risk of airborne infection with TTV in a room.

  13. Dynamic modeling and simulation of air-breathing proton exchange membrane fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Yalcinoz, T. [Department of Electrical and Computer Engineering, University of South Alabama, Mobile, AL 36688 (United States); Nigde University, Department of Electrical and Electronic Engineering, Nigde 51245 (Turkey); Alam, M.S. [Department of Electrical and Computer Engineering, University of South Alabama, Mobile, AL 36688 (United States)

    2008-07-15

    Small fuel cells have shown excellent potential as alternative energy sources for portable applications. One of the most promising fuel cell technologies for portable applications is air-breathing fuel cells. In this paper, a dynamic model of an air-breathing PEM fuel cell (AB-PEMFC) system is presented. The analytical modeling and simulation of the air-breathing PEM fuel cell system are verified using Matlab, Simulink and SimPowerSystems Blockset. To show the effectiveness of the proposed AB-PEMFC model, two case studies are carried out using the Matlab software package. In the first case study, the dynamic behavior of the proposed AB-PEMFC system is compared with that of a planar air-breathing PEM fuel cell model. In the second case study, the validation of the air-breathing PEM fuel cell-based power source is carried out for the portable application. Test results show that the proposed AB-PEMFC system can be considered as a viable alternative energy sources for portable applications. (author)

  14. Scintigraphic determination of gastrointestinal transit times. A comparison with breath hydrogen and radiologic methods

    DEFF Research Database (Denmark)

    Madsen, J L; Larsen, N E; Hilsted, J;

    1991-01-01

    A scintigraphic method for determination of gastrointestinal transit times was compared with the breath hydrogen test and a multiple-bolus, single-radiograph technique. A close temporal association was found between the caecal appearance of radioactivity and the onset of breath hydrogen excretion....... In conclusion, inadequate delineation of the caecal region seems to be an unimportant drawback of the scintigraphic measurements, whereas day-to-day variation in gastrointestinal transit rates may influence the reliability of the assessments. Probably, quantitative transit data cannot be obtained from...

  15. Human breath analysis may support the existence of individual metabolic phenotypes.

    Directory of Open Access Journals (Sweden)

    Pablo Martinez-Lozano Sinues

    Full Text Available The metabolic phenotype varies widely due to external factors such as diet and gut microbiome composition, among others. Despite these temporal fluctuations, urine metabolite profiling studies have suggested that there are highly individual phenotypes that persist over extended periods of time. This hypothesis was tested by analyzing the exhaled breath of a group of subjects during nine days by mass spectrometry. Consistent with previous metabolomic studies based on urine, we conclude that individual signatures of breath composition exist. The confirmation of the existence of stable and specific breathprints may contribute to strengthen the inclusion of breath as a biofluid of choice in metabolomic studies. In addition, the fact that the method is rapid and totally non-invasive, yet individualized profiles can be tracked, makes it an appealing approach.

  16. Students' Learning Strategies with Multiple Representations: Explanations of the Human Breathing Mechanism

    Science.gov (United States)

    Won, Mihye; Yoon, Heojeong; Treagust, David F.

    2014-01-01

    The purpose of this study was to understand how students utilized multiple representations to learn and explain science concepts, in this case the human breathing mechanism. The study was conducted with Grade 11 students in a human biology class. Semistructured interviews and a two-tier diagnostic test were administered to evaluate students'…

  17. Effect of breath holding on cerebrovascular hemodynamics in normal pregnancy and preeclampsia

    NARCIS (Netherlands)

    van Veen, Teelkien R.; Panerai, Ronney B.; Haeri, Sina; Zeeman, Gerda G.; Belfort, Michael A.

    2015-01-01

    Preeclampsia (PE) is associated with endothelial dysfunction and impaired autonomic function, which is hypothesized to cause cerebral hemodynamic abnormalities. Our aim was to test this hypothesis by estimating the difference in the cerebrovascular response to breath holding (BH; known to cause symp

  18. The classification of the patients with pulmonary diseases using breath air samples spectral analysis

    Science.gov (United States)

    Kistenev, Yury V.; Borisov, Alexey V.; Kuzmin, Dmitry A.; Bulanova, Anna A.

    2016-08-01

    Technique of exhaled breath sampling is discussed. The procedure of wavelength auto-calibration is proposed and tested. Comparison of the experimental data with the model absorption spectra of 5% CO2 is conducted. The classification results of three study groups obtained by using support vector machine and principal component analysis methods are presented.

  19. Multiple Genetic Analysis System-Based Antibiotic Susceptibility Testing in Helicobacter pylori and High Eradication Rate With Phenotypic Resistance-Guided Quadruple Therapy.

    Science.gov (United States)

    Dong, Fangyuan; Ji, Danian; Huang, Renxiang; Zhang, Fan; Huang, Yiqin; Xiang, Ping; Kong, Mimi; Nan, Li; Zeng, Xianping; Wu, Yong; Bao, Zhijun

    2015-11-01

    Antibiotics resistance in Helicobacter pylori (H. pylori) is the major factor for eradication failure. Molecular tests including fluorescence in situ hybridization, PCR-restriction fragment length polymorphism, and dual priming oligonucleotide-PCR (DPO-PCR) play critical roles in the detection of antibiotic susceptibility; however, limited knowledge is known about application of multiple genetic analysis system (MGAS) in the area of H. pylori identification and antibiotics resistance detection.The aim of this study is to determine the antibiotics resistance using different molecular tests and evaluate the treatment outcomes of E-test-based genotypic resistance.A total of 297 patients with dyspepsia complaint were recruited for gastroscopies. Ninety patients with H. pylori culture positive were randomly divided into 2 groups (test group and control group). E-test, general PCR, and MGAS assay were performed in test group. Patients in control group were treated with empirical therapy (rabeprazole + bismuth potassium citrate + amoxicillin [AMX] + clarithromycin [CLR]), whereas patients in test group received quadruple therapy based on E-test results twice daily for 14 consecutive days. The eradication effect of H. pylori was confirmed by C-urea breath test after at least 4 weeks when treatment was finished.Rapid urease test showed 46.5% (128/297) patients with H. pylori infection, whereas 30.3% (90/297) patients were H. pylori culture positive. E-test showed that H. pylori primary resistance rate to CLR, AMX, metronidazole, tetracycline, and levofloxacin (LVX) was 40.0% (18/45), 4.4% (2/45), 53.3% (24/45), 0% (0/45), and 55.6% (25/45), respectively. In addition, there are many multidrug resistant (MDR) phenotypes, and the MDR strains have higher minimum inhibitory concentration than their single-drug resistant counterparts. Considering E-test as the reference test, the sensitivities of general PCR and MGAS in detecting CLR resistance were 83.3% (15/18) and 94.4% (17

  20. First Breath prenatal smoking cessation pilot study: preliminary findings.

    Science.gov (United States)

    Jehn, Lisette; Lokker, Nicole; Matitz, Debra; Christiansen, Bruce

    2003-01-01

    Despite the many dangers associated with smoking during pregnancy, it remains a salient public health problem for Wisconsin women. The First Breath pilot program was developed in an attempt to reduce rates of smoking during pregnancy among low-income women. Preliminary results suggest that the First Breath counseling-based approach is effective, with a quit rate of 43.8% among First Breath enrollees at 1 month postpartum. Women receiving First Breath cessation counseling also had higher quit rates at every measurement period versus women in a comparison group who were receiving whatever cessation care was available in their county in the absence of First Breath. The First Breath pilot study has demonstrated success in helping pregnant women quit smoking and in creating a model for integration of cessation services into prenatal health care service provision. It is through this success that First Breath is expanding beyond the pilot study stage to a statewide program in 2003.

  1. Information dynamics in cardiorespiratory analyses: application to controlled breathing.

    Science.gov (United States)

    Widjaja, Devy; Faes, Luca; Montalto, Alessandro; Van Diest, Ilse; Marinazzo, Daniele; Van Huffel, Sabine

    2014-01-01

    Voluntary adjustment of the breathing pattern is widely used to deal with stress-related conditions. In this study, effects of slow and fast breathing with a low and high inspiratory to expiratory time on heart rate variability (HRV) are evaluated by means of information dynamics. Information transfer is quantified both as the traditional transfer entropy as well as the cross entropy, where the latter does not condition on the past of HRV, thereby taking the highly unidirectional relation between respiration and heart rate into account. The results show that the cross entropy is more suited to quantify cardiorespiratory information transfer as this measure increases during slow breathing, indicating the increased cardiorespiratory coupling and suggesting the shift towards vagal activation during slow breathing. Additionally we found that controlled breathing, either slow or fast, results as well in an increase in cardiorespiratory coupling, compared to spontaneous breathing, which demonstrates the beneficial effects of instructed breathing.

  2. Passive in-vehicle driver breath alcohol detection using advanced sensor signal acquisition and fusion.

    Science.gov (United States)

    Ljungblad, Jonas; Hök, Bertil; Allalou, Amin; Pettersson, Håkan

    2017-04-03

    The research objective of the present investigation is to demonstrate the present status of passive in-vehicle driver breath alcohol detection and highlighting the necessary conditions for large scale implementation of such a system. Completely passive detection has remained a challenge mainly because of the requirements on signal resolution combined with the constraints of vehicle integration. The work is part of the DADSS (driver alcohol detection system for safety) program aiming at massive deployment of alcohol sensing systems which could potentially save thousands of American lives annually. The work reported here builds on earlier investigations, in which it has been shown that detection of alcohol vapor in the proximity of a human subject may be traced to that subject by means of simultaneous recording of carbon dioxide (CO2) at the same location. Sensors based on infrared spectroscopy were developed to detect and quantify low concentrations of alcohol and CO2. In the present investigation, alcohol and CO2 were recorded at various locations in a vehicle cabin while human subjects were performing normal in-step procedures and driving preparations. A video camera directed to the driver position was recording images of the driver's upper body parts including the face, and the images were analyzed with respect to features of significance to the breathing behavior and breath detection, such as mouth opening and head direction. Improvement of the sensor system with respect to signal resolution including algorithm and software development, and fusion of the sensor and camera signals was successfully implemented and tested before starting the human study. In addition, experimental tests and simulations were performed with the purpose of connecting human subject data with repeatable experimental conditions. The results include occurrence statistics of detected breaths by signal peaks of CO2 and alcohol. From the statistical data, the accuracy of breath alcohol

  3. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

    Directory of Open Access Journals (Sweden)

    Peeyush Sahay

    2009-10-01

    Full Text Available Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS, cavity ringdown spectroscopy (CRDS, integrated cavity output spectroscopy (ICOS, cavity enhanced absorption spectroscopy (CEAS, cavity leak-out spectroscopy (CALOS, photoacoustic spectroscopy (PAS, quartz-enhanced photoacoustic spectroscopy (QEPAS, and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS. Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

  4. Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy

    Science.gov (United States)

    Dahnke, H.; Kleine, D.; Hering, P.; Mürtz, M.

    2001-06-01

    We report on spectroscopic real-time analysis of ethane traces in exhaled human breath. Ethane is considered the most important volatile marker of free-radical induced lipid peroxidation and cell damage in the human body. Our measurements were carried out by means of mid-infrared cavity leak-out spectroscopy in the 3 μm region, a cw variant of cavity ring-down spectroscopy. The spectrometer is based on a CO overtone laser with tunable microwave sidebands. The resulting system proved to be an unique tool with high sensitivity and selectivity for rapid and precise breath testing. With a 5 s integration time, we achieved a detection limit on the order of 100 parts per trillion ethane in human breath. Thus, sample preconcentration is unnecessary. Time-resolved monitoring of the decaying ethane fraction in breath after smoking a cigarette is demonstrated.

  5. Fiber content of diet affects exhaled breath volatiles in fasting and postprandial state in a pilot crossover study.

    Science.gov (United States)

    Raninen, Kaisa J; Lappi, Jenni E; Mukkala, Maria L; Tuomainen, Tomi-Pekka; Mykkänen, Hannu M; Poutanen, Kaisa S; Raatikainen, Olavi J

    2016-06-01

    Our pilot study examined the potential of exhaled breath analysis in studying the metabolic effects of dietary fiber (DF). We hypothesized that a high-fiber diet (HFD) containing whole grain rye changes volatile organic compound (VOC) levels in exhaled breath and that consuming a single meal affects these levels. Seven healthy men followed a week-long low-fiber diet (17 g/d) and HFD (44 g/d) in a randomized crossover design. A test meal containing 50 g of the available carbohydrates from wheat bread was served as breakfast after each week. Alveolar exhaled breath samples were analyzed at fasting state and 30, 60, and 120 minutes after this meal parallel to plasma glucose, insulin, and serum lipids. We used solid-phase microextraction and gas chromatography-mass spectrometry for detecting changes in 15 VOCs. These VOCs were acetone, ethanol, 1-propanol, 2-propanol, 1-butanol, acetic acid, propionic acid, butyric acid, valeric acid, isovaleric acid, 2-methylbutyric acid, hexanoic acid, acetoin, diacetyl, and phenol. Exhaled breath 2-methylbutyric acid in the fasting state and 1-propanol at 120 minutes decreased (P = .091 for both) after an HFD. Ingestion of the test meal increased ethanol, 1-propanol, acetoin, propionic acid, and butyric acid levels while reducing acetone, 1-butanol, diacetyl, and phenol levels. Both DF diet content and having a single meal affected breathVOCs. Exploring exhaled breath further could help to develop tools for monitoring the metabolic effects of DF.

  6. Breathing dissipative solitons in optical microresonators

    CERN Document Server

    Lucas, Erwan; Guo, Hairun; Gorodetsky, Michael; Kippenberg, Tobias

    2016-01-01

    Dissipative solitons are self-localized structures resulting from a double balance between dispersion and nonlinearity as well as dissipation and a driving force. They occur in a wide variety of fields ranging from optics, hydrodynamics to chemistry and biology. Recently, significant interest has focused on their temporal realization in driven optical microresonators, known as dissipative Kerr solitons. They provide access to coherent, chip-scale optical frequency combs, which have already been employed in optical metrology, data communication and spectroscopy. Such Kerr resonator systems can exhibit numerous localized intracavity patterns and provide rich insights into nonlinear dynamics. A particular class of solutions consists of breathing dissipative solitons, representing pulses with oscillating amplitude and duration, for which no comprehensive understanding has been presented to date. Here, we observe and study single and multiple breathing dissipative solitons in two different microresonator platforms...

  7. Protective supplied-breathing-air garment

    Science.gov (United States)

    Childers, E.L.; von Hortenau, E.F.

    1982-05-28

    A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

  8. Atypical streptococcal infection of gingiva associated with chronic mouth breathing.

    Science.gov (United States)

    Haytac, M Cenk; Oz, I Attila

    2007-01-01

    Streptococcal infections of oral tissues are mainly seen in young children who experience a variety of upper respiratory tract infections. The disease is characterized by fever, lymphadenopathy, and ulcers on the gingiva, lips, and tonsils. This case report presents an atypical streptococcal infection of the gingiva in an 18-year-old man. The patient was referred to the periodontology department complaining of a 2-month history of gingival enlargement. He had persistent fever (39.5 degrees C) and general malaise for 2 weeks. Intraoral examination revealed extremely inflamed and enlarged gingiva with spontaneous bleeding and suppuration. Based on the otolaryngologic consultation and the hematologic, immunologic, and microbiologic tests, the final diagnosis was an atypical streptococcal gingivitis with chronic adenoid-related mouth breathing and oral hygiene neglect as contributing factors. Treatment consisted of a broad-spectrum antibiotic regimen, supragingival and subgingival debridement, adenoidectomy, and scaling and root planing. A good response to nonsurgical therapy was achieved despite poor patient compliance, and no recurrence of gingival enlargement was observed after 1 year. Streptococcal gingivitis should be included in the differential diagnosis of suppurative gingival enlargements. Furthermore, chronic mouth breathing may initiate and/or contribute to this disease.

  9. C-130J Breathing Resistance Study

    Science.gov (United States)

    2016-05-01

    flows used in the study . The simulated workloads were: 1) 60 ALPM: Rest; 2) 90 ALPM: Light Work ; 3) 125 ALPM: Moderate Work ; and 4) 150 ALPM...AFRL-RH-WP-TR-2016-0040 C-130J BREATHING RESISTANCE STUDY George W. Miller Air Force Research Laboratory Wright-Patterson Air...ASSIGNED DISTRIBUTION STATEMENT. //signed// //signed// GEORGE W. MILLER SCOTT M. GALSTER Work Unit Manager Chief, Applied

  10. Loss of Breathing Modulation of Heart Rate Variability in Patients with Recent and Long Standing Diabetes Mellitus Type II

    Science.gov (United States)

    Estañol, Bruno; Fossion, Ruben; Toledo-Roy, Juan C.; Callejas-Rojas, José A.; Gien-López, José A.; Delgado-García, Guillermo R.; Frank, Alejandro

    2016-01-01

    Healthy subjects under rhythmic breathing have heart interbeat intervals with a respiratory band in the frequency domain that can be an index of vagal activity. Diabetes Mellitus Type II (DM) affects the autonomic nervous system of patients, thus it can be expected changes on the vagal activity. Here, the influence of DM on the breathing modulation of the heart rate is evaluated by analyzing in the frequency domain heart interbeat interval (IBI) records obtained from 30 recently diagnosed, 15 long standing DM patients, and 30 control subjects during standardized clinical tests of controlled breathing at 0.1 Hz, supine rest and standing upright. Fourier spectral analysis of IBI records quantifies heart rate variability in different regions: low-frequencies (LF, 0.04–0.15 Hz), high-frequencies (HF, 0.15–0.4 Hz), and a controlled breathing peak (RP, centered around 0.1 Hz). Two new parameters are introduced: the frequency radius rf (square root of the sum of LF and HF squared) and β (power of RP divided by the sum of LF and HF). As diabetes evolves, the controlled breathing peak loses power and shifts to smaller frequencies, indicating that heart rate modulation is slower in diabetic patients than in controls. In contrast to the traditional parameters LF, HF and LF/HF, which do not show significant differences between the three populations in neither of the clinical tests, the new parameters rf and β, distinguish between control and diabetic subjects in the case of controlled breathing. Sympathetic activity that is driven by the baroreceptor reflex associated with the 0.1 Hz breathing modulations is affected in DM patients. Diabetes produces not only a rigid heartbeat with less autonomic induced variability (rf diminishes), but also alters the coupling between breathing and heart rate (reduced β), due to a progressive decline of vagal and sympathetic activity. PMID:27802329

  11. 13C-labeled mixed triglyceride breath test (13C MTG-BT) in healthy children and children with cystic fibrosis (CF) under pancreatic enzyme replacement therapy (PERT): a pilot study.

    Science.gov (United States)

    Herzog, Denise C; Delvin, Edgard E; Albert, Caroline; Marcotte, Jacques E; Pelletier, Véronique A; Seidman, Ernest G

    2008-12-01

    The MTG-BT estimates the hydrolysis of triacyl-glycerols by pancreatic lipase, and appears attractive for monitoring exogenous lipase requirements in patients with exocrine pancreatic insufficiency. To assess the test's discrimination capacity and repeatability, 9 CF patients with PERT and 10 healthy children underwent the (13)C-MTG-BT twice, at a 2- to 4-week interval. The test distinguished well between patients with severe exocrine pancreatic insufficiency (SEPI) and healthy subjects. However, within-subject variability for postprandial per thousand(13)C-enrichment and postprandial % dose recovery (PDR) was high in both groups. Therefore, the (13)C-MTG-BT seems useful to distinguish between SEPI and normal exocrine pancreatic function, but requires further development to improve its repeatability.

  12. Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Plathow, Christian [German Cancer Research Center Heidelberg, Department of Radiology, Heidelberg (Germany); Eberhard-Karls-University Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Ley, Sebastian; Zaporozhan, Julia; Puderbach, Michael; Eichinger, Monika; Zuna, Ivan; Kauczor, Hans-Ulrich [German Cancer Research Center Heidelberg, Department of Radiology, Heidelberg (Germany); Schoebinger, Max; Meinzer, Hans-Peter [German Cancer Research Center Heidelberg, Department of Medical and Biological Informatics, Heidelberg (Germany); Gruenig, Ekkehard [University of Heidelberg, Department of Internal Medicine III, Heidelberg (Germany)

    2006-01-01

    To assess the stability and reproducibility of different breath-hold levels in healthy volunteers and patients using dynamic MRI (dMRI). In ten healthy volunteers and ten patients with pulmonary hypertension (PH) and normal lung function craniocaudal intrathoracic distances (CCD) were measured during inspiratory and expiratory breath-hold (15 s) (in healthy volunteers additionally at a self-chosen mid-inspiratory breath-hold) using dMRI (trueFISP, three images/s). To evaluate stability and intraobserver reproducibility of the different breath-hold levels, CCDs, time-distance curves, confidence intervals (CIs), Mann-Witney U test and regression equations were calculated. In healthy volunteers there was a substantial decrease of the CCD during the inspiratory breath-hold in contrast to the expiratory breath-hold. The CI at inspiration was 2.84{+-}1.28 in the right and 2.1{+-}0.68 in the left hemithorax. At expiration the CI was 2.54{+-}1.18 and 2.8{+-}1.48. Patients were significantly less able to hold their breath at inspiration than controls (P<0.05). In patients CI was 4.53{+-}4.06 and 3.46{+-}2.21 at inspiration and 4.45{+-}4.23 and 4.76{+-}3.73 at expiration. Intraobserver variability showed no significant differences either in patients or in healthy subjects. Reproducibility was significantly lower at a self-chosen breath-hold level of the healthy volunteers. DMRI is able to differentiate stability and reproducibility of different breath-hold levels. Expiratory breath-hold proved to be more stable than inspiratory breath-hold in healthy volunteers and patients. (orig.)

  13. Determination of breath isoprene allows the identification of the expiratory fraction of the propofol breath signal during real-time propofol breath monitoring.

    Science.gov (United States)

    Hornuss, Cyrill; Dolch, Michael E; Janitza, Silke; Souza, Kimberly; Praun, Siegfried; Apfel, Christian C; Schelling, Gustav

    2013-10-01

    Real-time measurement of propofol in the breath may be used for routine clinical monitoring. However, this requires unequivocal identification of the expiratory phase of the respiratory propofol signal as only expiratory propofol reflects propofol blood concentrations. Determination of CO2 breath concentrations is the current gold standard for the identification of expiratory gas but usually requires additional equipment. Human breath also contains isoprene, a volatile organic compound with low inspiratory breath concentration and an expiratory concentration plateau. We investigated whether breath isoprene could be used similarly to CO2 to identify the expiratory fraction of the propofol breath signal. We investigated real-time breath data obtained from 40 study subjects during routine anesthesia. Propofol, isoprene, and CO2 breath concentrations were determined by a combined ion molecule reaction/electron impact mass spectrometry system. The expiratory propofol signal was identified according to breath CO2 and isoprene concentrations and presented as median of intervals of 30 s duration. Bland-Altman analysis was applied to detect differences (bias) in the expiratory propofol signal extracted by the two identification methods. We investigated propofol signals in a total of 3,590 observation intervals of 30 s duration in the 40 study subjects. In 51.4 % of the intervals (1,844/3,590) both methods extracted the same results for expiratory propofol signal. Overall bias between the two data extraction methods was -0.12 ppb. The lower and the upper limits of the 95 % CI were -0.69 and 0.45 ppb. Determination of isoprene breath concentrations allows the identification of the expiratory propofol signal during real-time breath monitoring.

  14. Multifrequency high precise subTHz-THz-IR spectroscopy for exhaled breath research

    Science.gov (United States)

    Vaks, Vladimir L.; Domracheva, Elena G.; Pripolzin, Sergey I.; Chernyaeva, Mariya B.

    2016-09-01

    Nowadays the development of analytical spectroscopy with high performance, sensitivity and spectral resolution for exhaled breath research is attended. The method of two-frequency high precise THz spectroscopy and the method of high precise subTHz-THz-IR spectroscopy are presented. Development of a subTHz-THz-IR gas analyzer increases the number of gases that can be identified and the reliability of the detection by confirming the signature in both THz and MIR ranges. The testing measurements have testified this new direction of analytical spectroscopy to open widespread trends of its using for various problems of medicine and biology. First of all, there are laboratory investigations of the processes in exhaled breath and studying of their dynamics. Besides, the methods presented can be applied for detecting intermediate and short time living products of reactions in exhaled breath. The spectrometers have been employed for investigations of acetone, methanol and ethanol in the breath samples of healthy volunteers and diabetes patients. The results have demonstrated an increased concentration of acetone in breath of diabetes patients. The dynamic of changing the acetone concentration before and after taking the medicines is discovered. The potential markers of pre-cancer states and oncological diseases of gastrointestinal tract organs have been detected. The changes in the NO concentration in exhaled breath of cancer patients during radiotherapy as well as increase of the NH3 concentration at gastrointestinal diseases have been revealed. The preliminary investigations of biomarkers in three frequency ranges have demonstrated the advantages of the multifrequency high precise spectroscopy for noninvasive medical diagnostics.

  15. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    Directory of Open Access Journals (Sweden)

    Paolo Domenici

    2014-12-01

    Full Text Available Fast-starts are brief accelerations commonly observed in fish within the context of predator–prey interactions. In typical C-start escape responses, fish react to a threatening stimulus by bending their body into a C-shape during the first muscle contraction (i.e. stage 1 which provides a sudden acceleration away from the stimulus. Recently, similar C-starts have been recorded in fish aiming at a prey. Little is known about C-starts outside the context of predator–prey interactions, though recent work has shown that escape response can also be induced by high temperature. Here, we test the hypothesis that air-breathing fish may use C-starts in the context of gulping air at the surface. Hoplosternum littorale is an air-breathing freshwater catfish found in South America. Field video observations reveal that their air-breathing behaviour consists of air-gulping at the surface, followed by a fast turn which re-directs the fish towards the bottom. Using high-speed video in the laboratory, we compared the kinematics of the turn immediately following air-gulping performed by H. littorale in normoxia with those of mechanically-triggered C-start escape responses and with routine (i.e. spontaneous turns. Our results show that air-breathing events overlap considerably with escape responses with a large stage 1 angle in terms of turning rates, distance covered and the relationship between these rates. Therefore, these two behaviours can be considered kinematically comparable, suggesting that air-breathing in this species is followed by escape-like C-start motions, presumably to minimise time at the surface and exposure to avian predators. These findings show that C-starts can occur in a variety of contexts in which fish may need to get away from areas of potential danger.

  16. Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, Laura; O' Brien, Kendall J. [Children' s National Health System, Division of Cardiology, Washington, DC (United States); National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States); Cross, Russell [Children' s National Health System, Division of Cardiology, Washington, DC (United States); Xue, Hui; Kellman, Peter; Hansen, Michael S. [National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD (United States)

    2016-06-15

    The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late

  17. Coordination-related changes in the rhythms of breathing and walking in humans.

    Science.gov (United States)

    Rassler, B; Kohl, J

    2000-07-01

    Coordination of the respiratory rhythm with the rhythm of limb movements has often been observed during rhythmical exercise (e.g. in locomotion). It is usually associated with changes in the respiratory time course, but not in the locomotor rhythm. Therefore, we hypothesised that in walking, the extent of coordination-related changes (CRC) in respiratory parameters would increase with closer coordination. With respect to the controversially discussed question of a possible energetic advantage due to coordination, we devoted particular interest to the CRC in oxygen uptake (VO2). In addition, we investigated the incidence and the extent of CRC in the stepping rhythm. We examined 18 volunteers walking on a treadmill at three different workload levels, which were adjusted by altering either the velocity or slope of the treadmill. Each walking test was carried out twice, once with spontaneous breathing and once with breathing paced by a step-related acoustic signal to enhance the coordination between breathing and walking. No correlation was found between the CRC in the analysed parameters and the degree of coordination. However, the extent of CRC of ventilation and VO2 decreased with increasing workload. With the transition to coordination, increases and decreases of VO2 occurred about equally often. From this we conclude that energetic economisation in walking, as reflected by a reduction in VO2, is rather a side-effect of coordination, and is probably due to a more precise regulation of the breathing pattern. The economisation was more pronounced at higher work loads than at lower work loads. Our results revealed that coordination is also associated with changes in the stepping rate, which occurred more frequently when the variability of breathing was restricted by acoustic pacing of the breathing rhythm. This finding suggests that the choice of walking rhythm is not completely free, but can be influenced by the breathing rhythm. CRC in the walking rhythm might

  18. Bench experiments comparing simulated inspiratory effort when breathing helium-oxygen mixtures to that during positive pressure support with air

    Directory of Open Access Journals (Sweden)

    Martin Andrew R

    2012-10-01

    Full Text Available Abstract Background Inhalation of helium-oxygen (He/O2 mixtures has been explored as a means to lower the work of breathing of patients with obstructive lung disease. Non-invasive ventilation (NIV with positive pressure support is also used for this purpose. The bench experiments presented herein were conducted in order to compare simulated patient inspiratory effort breathing He/O2 with that breathing medical air, with or without pressure support, across a range of adult, obstructive disease patterns. Methods Patient breathing was simulated using a dual-chamber mechanical test lung, with the breathing compartment connected to an ICU ventilator operated in NIV mode with medical air or He/O2 (78/22 or 65/35%. Parabolic or linear resistances were inserted at the inlet to the breathing chamber. Breathing chamber compliance was also varied. The inspiratory effort was assessed for the different gas mixtures, for three breathing patterns, with zero pressure support (simulating unassisted spontaneous breathing, and with varying levels of pressure support. Results Inspiratory effort increased with increasing resistance and decreasing compliance. At a fixed resistance and compliance, inspiratory effort increased with increasing minute ventilation, and decreased with increasing pressure support. For parabolic resistors, inspiratory effort was lower for He/O2 mixtures than for air, whereas little difference was measured for nominally linear resistance. Relatively small differences in inspiratory effort were measured between the two He/O2 mixtures. Used in combination, reductions in inspiratory effort provided by He/O2 and pressure support were additive. Conclusions The reduction in inspiratory effort afforded by breathing He/O2 is strongly dependent on the severity and type of airway obstruction. Varying helium concentration between 78% and 65% has small impact on inspiratory effort, while combining He/O2 with pressure support provides an additive

  19. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    Science.gov (United States)

    Duan, Yixiang; Cao, Wenqing

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  20. Development of Techniques for Trace Gas Detection in Breath

    OpenAIRE

    2012-01-01

    This thesis aims to investigate the possibility of developing spectroscopic techniques for trace gas detection, with particular emphasis on their applicability to breath analysis and medical diagnostics. Whilst key breath molecules such as methane and carbon dioxide will feature throughout this work, the focus of the research is on the detection of breath acetone, a molecule strongly linked with the diabetic condition. Preliminary studies into the suitability of cavity enhanced absorption...

  1. Design and Implementation of a Laser-Based Ammonia Breath Sensor for Medical Applications

    KAUST Repository

    Owen, Kyle

    2012-06-01

    Laser-based sensors can be used as non-invasive monitoring tools to measure parts per billion (ppb) levels of trace gases. Ammonia sensors are useful for applications in environmental pollutant monitoring, atmospheric and combustion kinetic studies, and medical diagnostics. This sensor was specifically designed to measure ammonia in exhaled breath to be used as a medical diagnostic and monitoring tool, however, it can also be extended for use in other applications. Although ammonia is a naturally occurring species in exhaled breath, abnormally elevated levels can be an indication of adverse medical conditions. Laser-based breath diagnostics have many benefits since they are cost effective, non-invasive, painless, real time monitors. They have the potential to improve the quality of medical care by replacing currently used blood tests and providing immediate feedback to physicians. This sensor utilizes a Quantum Cascade Laser and Wavelength Modulation Spectroscopy with second harmonic normalized by first harmonic detection in a 76 m multi-pass absorption cell to measure ppb levels of ammonia with improved sensitivity over previous sensors. Initial measurements to determine the ammonia absorption line parameters were performed using direct absorption spectroscopy. This is the first experimental study of the ammonia absorption line transitions near 1103.46 cm1 with absorption spectroscopy. The linestrengths were measured with uncertainties less than 10%. The collisional broadening coefficients for each of the ammonia lines with nitrogen, oxygen, water vapor, and carbon dioxide were also measured, many of which had uncertainties less than 5%. The sensor was characterized to show a detectability limit of 10 ppb with an uncertainty of less than 5% at typical breath ammonia levels. Initial breath test results showed that some of the patients with chronic kidney disease had elevated ammonia levels while others had ammonia levels in the same range as expected for healthy

  2. General Anesthesia with Preserved Spontaneous Breathing through an Intubation Tube

    Directory of Open Access Journals (Sweden)

    V. V. Moroz

    2010-01-01

    Full Text Available Objective: to study whether spontaneous patient breathing may be preserved during elective operations under general anesthesia with tracheal intubation. Subjects and methods. One hundred and twelve patients undergoing elective surgeries under general endotracheal anesthesia were randomized into 2 groups: 1 patients who had forced mechanical ventilation in the volume-controlled mode and 2 those who received assisted ventilation as spontaneous breathing with mechanical support. Conclusion. The study shows that spontaneous breathing with mechanical support may be safely used during some surgical interventions in patients with baseline healthy lungs. Key words: Pressure Support, assisted ventilation, spontaneous breathing, general anesthesia, lung function.

  3. Using acoustic sensors to discriminate between nasal and mouth breathing.

    Science.gov (United States)

    Curran, Kevin; Yuan, Peng; Coyle, Damian

    2012-01-01

    The recommendation to change breathing patterns from the mouth to the nose can have a significantly positive impact upon the general well being of the individual. We classify nasal and mouth breathing by using an acoustic sensor and intelligent signal processing techniques. The overall purpose is to investigate the possibility of identifying the differences in patterns between nasal and mouth breathing in order to integrate this information into a decision support system which will form the basis of a patient monitoring and motivational feedback system to recommend the change from mouth to nasal breathing.

  4. A fibre-optic oxygen sensor for monitoring human breathing.

    Science.gov (United States)

    Chen, Rongsheng; Formenti, Federico; Obeid, Andy; Hahn, Clive E W; Farmery, Andrew D

    2013-09-01

    The development and construction of a tapered-tip fibre-optic fluorescence based oxygen sensor is described. The sensor is suitable for fast and real-time monitoring of human breathing. The sensitivity and response time of the oxygen sensor were evaluated in vitro with a gas pressure chamber system, where oxygen partial pressure was rapidly changed between 5 and 15 kPa, and then in vivo in five healthy adult participants who synchronized their breathing to a metronome set at 10, 20, 30, 40, 50, and 60 breaths min(-1). A Datex Ultima medical gas analyser was used to monitor breathing rate as a comparator. The sensor's response time in vitro was less than 150 ms, which allows accurate continuous measurement of inspired and expired oxygen pressure. Measurements of breathing rate by means of our oxygen sensor and of the Datex Ultima were in strong agreement. The results demonstrate that the device can reliably resolve breathing rates up to 60 breaths min(-1), and that it is a suitable cost-effective alternative for monitoring breathing rates and end-tidal oxygen partial pressure in the clinical setting. The rapid response time of the sensor may allow its use for monitoring rapid breathing rates as occur in children and the newborn.

  5. Can resistive breathing injure the lung? Implications for COPD exacerbations

    Directory of Open Access Journals (Sweden)

    Vassilakopoulos T

    2016-09-01

    Full Text Available Theodoros Vassilakopoulos, Dimitrios Toumpanakis Pulmonary and Critical Care Medicine, Medical School, National and Kapodistrian University of Athens, Greece Abstract: In obstructive lung diseases, airway inflammation leads to bronchospasm and thus resistive breathing, especially during exacerbations. This commentary discusses experimental evidence that resistive breathing per se (the mechanical stimulus in the absence of underlying airway inflammation leads to lung injury and inflammation (mechanotransduction. The potential implications of resistive breathing-induced mechanotrasduction in COPD exacerbations are presented along with the available clinical evidence. Keywords: resistive breathing, COPD, mechanotransduction, bronchoconstriction, inflammation

  6. Sports-related lung injury during breath-hold diving

    Directory of Open Access Journals (Sweden)

    Tanja Mijacika

    2016-12-01

    Full Text Available The number of people practising recreational breath-hold diving is constantly growing, thereby increasing the need for knowledge of the acute and chronic effects such a sport could have on the health of participants. Breath-hold diving is potentially dangerous, mainly because of associated extreme environmental factors such as increased hydrostatic pressure, hypoxia, hypercapnia, hypothermia and strenuous exercise. In this article we focus on the effects of breath-hold diving on pulmonary function. Respiratory symptoms have been reported in almost 25% of breath-hold divers after repetitive diving sessions. Acutely, repetitive breath-hold diving may result in increased transpulmonary capillary pressure, leading to noncardiogenic oedema and/or alveolar haemorrhage. Furthermore, during a breath-hold dive, the chest and lungs are compressed by the increasing pressure of water. Rapid changes in lung air volume during descent or ascent can result in a lung injury known as pulmonary barotrauma. Factors that may influence individual susceptibility to breath-hold diving-induced lung injury range from underlying pulmonary or cardiac dysfunction to genetic predisposition. According to the available data, breath-holding does not result in chronic lung injury. However, studies of large populations of breath-hold divers are necessary to firmly exclude long-term lung damage.

  7. Sports-related lung injury during breath-hold diving.

    Science.gov (United States)

    Mijacika, Tanja; Dujic, Zeljko

    2016-12-01

    The number of people practising recreational breath-hold diving is constantly growing, thereby increasing the need for knowledge of the acute and chronic effects such a sport could have on the health of participants. Breath-hold diving is potentially dangerous, mainly because of associated extreme environmental factors such as increased hydrostatic pressure, hypoxia, hypercapnia, hypothermia and strenuous exercise.In this article we focus on the effects of breath-hold diving on pulmonary function. Respiratory symptoms have been reported in almost 25% of breath-hold divers after repetitive diving sessions. Acutely, repetitive breath-hold diving may result in increased transpulmonary capillary pressure, leading to noncardiogenic oedema and/or alveolar haemorrhage. Furthermore, during a breath-hold dive, the chest and lungs are compressed by the increasing pressure of water. Rapid changes in lung air volume during descent or ascent can result in a lung injury known as pulmonary barotrauma. Factors that may influence individual susceptibility to breath-hold diving-induced lung injury range from underlying pulmonary or cardiac dysfunction to genetic predisposition.According to the available data, breath-holding does not result in chronic lung injury. However, studies of large populations of breath-hold divers are necessary to firmly exclude long-term lung damage.

  8. Optimal technique for deep breathing exercises after cardiac surgery.

    Science.gov (United States)

    Westerdahl, E

    2015-06-01

    Cardiac surgery patients often develop a restrictive pulmonary impairment and gas exchange abnormalities in the early postoperative period. Chest physiotherapy is routinely prescribed in order to reduce or prevent these complications. Besides early mobilization, positioning and shoulder girdle exercises, various breathing exercises have been implemented as a major component of postoperative care. A variety of deep breathing maneuvres are recommended to the spontaneously breathing patient to reduce atelectasis and to improve lung function in the early postoperative period. Different breathing exercises are recommended in different parts of the world, and there is no consensus about the most effective breathing technique after cardiac surgery. Arbitrary instructions are given, and recommendations on performance and duration vary between hospitals. Deep breathing exercises are a major part of this therapy, but scientific evidence for the efficacy has been lacking until recently, and there is a lack of trials describing how postoperative breathing exercises actually should be performed. The purpose of this review is to provide a brief overview of postoperative breathing exercises for patients undergoing cardiac surgery via sternotomy, and to discuss and suggest an optimal technique for the performance of deep breathing exercises.

  9. Electronic response to nuclear breathing mode

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Hendrik; Ruffini, Remo [ICRANet, P.zza della Repubblica 10, I-65122 Pescara, Italy Dipartimento di Fisica and ICRA, Sapienza Università di Roma P.le Aldo Moro 5, I-00185 Rome (Italy); ICRANet, University of Nice-Sophia Antipolis, 28 Av. de Valrose, 06103 Nice Cedex 2 (France); Xue, She-Sheng [ICRANet, P.zza della Repubblica 10, I-65122 Pescara, Italy Dipartimento di Fisica and ICRA, Sapienza Università di Roma P.le Aldo Moro 5, I-00185 Rome (Italy)

    2015-12-17

    Based on our previous work on stationary oscillation modes of electrons around giant nuclei, we show how to treat a general driving force on the electron gas, such as the one generated by the breathing mode of the nucleus, by means of the spectral method. As an example we demonstrate this method for a system with Z = 10{sup 4} in β-equilibrium with the electrons compressed up to the nuclear radius. In this case the stationary modes can be obtained analytically, which allows for a very speedy numerical calculation of the final result.

  10. Exhaled breath condensate pH assays.

    Science.gov (United States)

    Davis, Michael D; Hunt, John

    2012-08-01

    Airway pH is central to the physiologic function and cellular biology of the airway. The causes of airway acidification include (1) hypopharyngeal gastric acid reflux with or without aspiration through the vocal cords, (2) inhalation of acid fog or gas (such as chlorine), and (3) intrinsic airway acidification caused by altered airway pH homeostasis in infectious and inflammatory disease processes. The recognition that relevant airway pH deviations occur in lung diseases is opening doors to new simple and inexpensive therapies. This recognition has resulted partly from the ability to use exhaled breath condensate as a window on airway acid-base balance.

  11. Exhaled Breath Condensate for Proteomic Biomarker Discovery

    Directory of Open Access Journals (Sweden)

    Sean W. Harshman

    2014-07-01

    Full Text Available Exhaled breath condensate (EBC has been established as a potential source of respiratory biomarkers. Compared to the numerous small molecules identified, the protein content of EBC has remained relatively unstudied due to the methodological and technical difficulties surrounding EBC analysis. In this review, we discuss the proteins identified in EBC, by mass spectrometry, focusing on the significance of those proteins identified. We will also review the limitations surrounding mass spectral EBC protein analysis emphasizing recommendations to enhance EBC protein identifications by mass spectrometry. Finally, we will provide insight into the future directions of the EBC proteomics field.

  12. Extensive Epidermoid Cyst and Breathing Difficulty

    Directory of Open Access Journals (Sweden)

    Ciro Dantas Soares

    2015-01-01

    Full Text Available Epidermoid cysts are common cystic lesions in the skin, ovaries, and testicles, but their occurrence in the oral cavity is uncommon. They consist of cysts delimited by a fibrous capsule without cutaneous annexes and are lined by stratified squamous epithelium. The differential diagnosis includes ranula, dermoid cysts, and lingual thyroid. Despite their benign presentation, these cysts can cause functional limitations, requiring special clinical attention for extensive lesions located in regions that preserve vital structures. This paper aims to report a case of epidermoid cyst in patient with swallowing and breathing difficulty, highlighting the clinical and surgical planning.

  13. A young male with shortness of breath

    Directory of Open Access Journals (Sweden)

    Khan Fahmi

    2008-01-01

    Full Text Available We report a case of primary mediastinal seminoma, which presented initially with shortness of breath and a swelling in upper part of anterior chest wall. The diagnosis of primary mediastinal seminoma was established on the basis of histologic findings and was confirmed by immunohistochemical analysis. Abdominal, pelvis and cerebral CT scan, testicular ultrasound and TC-99 MDP bone scintigraphy were negative. Chemotherapy was initiated with B.E.P. protocol (Bleomycin, Etoposide, Cisplatinum; the patient received four cycles of chemotherapy. After 8 months, the patient was seen in the clinic; he was well.

  14. Extensive Epidermoid Cyst and Breathing Difficulty

    Science.gov (United States)

    Soares, Ciro Dantas; Gurgel, Alberto Costa; de Souza Júnior, Francisco de Assis; de Oliveira, Samila Neres; de Carvalho, Maria Goretti Freire; Oliveira, Hanieri Gustavo

    2015-01-01

    Epidermoid cysts are common cystic lesions in the skin, ovaries, and testicles, but their occurrence in the oral cavity is uncommon. They consist of cysts delimited by a fibrous capsule without cutaneous annexes and are lined by stratified squamous epithelium. The differential diagnosis includes ranula, dermoid cysts, and lingual thyroid. Despite their benign presentation, these cysts can cause functional limitations, requiring special clinical attention for extensive lesions located in regions that preserve vital structures. This paper aims to report a case of epidermoid cyst in patient with swallowing and breathing difficulty, highlighting the clinical and surgical planning. PMID:26180645

  15. Appropriate sample bags and syringes for preserving breath samples in breath odor research : a technical note

    NARCIS (Netherlands)

    Winkel, E. G.; Tangerman, A.

    2008-01-01

    It is now generally accepted that the volatile sulfur compounds (VSCs) hydrogen sulfide, methyl mercaptan and dimethyl sulfide are the main contributors to halitosis when of oropharyngeal origin. The VSCs hydrogen sulfide and methyl mercaptan are the major causes of bad breath in oral malodour where

  16. Work of Breathing into Snow in the Presence versus Absence of an Artificial Air Pocket Affects Hypoxia and Hypercapnia of a Victim Covered with Avalanche Snow: A Randomized Double Blind Crossover Study.

    Directory of Open Access Journals (Sweden)

    Karel Roubík

    Full Text Available Presence of an air pocket and its size play an important role in survival of victims buried in the avalanche snow. Even small air pockets facilitate breathing. We hypothesize that the size of the air pocket significantly affects the airflow resistance and work of breathing. The aims of the study are (1 to investigate the effect of the presence of an air pocket on gas exchange and work of breathing in subjects breathing into the simulated avalanche snow and (2 to test whether it is possible to breathe with no air pocket. The prospective interventional double-blinded study involved 12 male volunteers, from which 10 completed the whole protocol. Each volunteer underwent two phases of the experiment in a random order: phase "AP"--breathing into the snow with a one-liter air pocket, and phase "NP"--breathing into the snow with no air pocket. Physiological parameters, fractions of oxygen and carbon dioxide in the airways and work of breathing expressed as pressure-time product were recorded continuously. The main finding of the study is that it is possible to breath in the avalanche snow even with no air pocket (0 L volume, but breathing under this condition is associated with significantly increased work of breathing. The significant differences were initially observed for end-tidal values of the respiratory gases (EtO2 and EtCO2 and peripheral oxygen saturation (SpO2 between AP and NP phases, whereas significant differences in inspiratory fractions occurred much later (for FIO2 or never (for FICO2. The limiting factor in no air pocket conditions is excessive increase in work of breathing that induces increase in metabolism accompanied by higher oxygen consumption and carbon dioxide production. The presence of even a small air pocket reduces significantly the work of breathing.

  17. Work of Breathing into Snow in the Presence versus Absence of an Artificial Air Pocket Affects Hypoxia and Hypercapnia of a Victim Covered with Avalanche Snow: A Randomized Double Blind Crossover Study.

    Science.gov (United States)

    Roubík, Karel; Sieger, Ladislav; Sykora, Karel

    2015-01-01

    Presence of an air pocket and its size play an important role in survival of victims buried in the avalanche snow. Even small air pockets facilitate breathing. We hypothesize that the size of the air pocket significantly affects the airflow resistance and work of breathing. The aims of the study are (1) to investigate the effect of the presence of an air pocket on gas exchange and work of breathing in subjects breathing into the simulated avalanche snow and (2) to test whether it is possible to breathe with no air pocket. The prospective interventional double-blinded study involved 12 male volunteers, from which 10 completed the whole protocol. Each volunteer underwent two phases of the experiment in a random order: phase "AP"--breathing into the snow with a one-liter air pocket, and phase "NP"--breathing into the snow with no air pocket. Physiological parameters, fractions of oxygen and carbon dioxide in the airways and work of breathing expressed as pressure-time product were recorded continuously. The main finding of the study is that it is possible to breath in the avalanche snow even with no air pocket (0 L volume), but breathing under this condition is associated with significantly increased work of breathing. The significant differences were initially observed for end-tidal values of the respiratory gases (EtO2 and EtCO2) and peripheral oxygen saturation (SpO2) between AP and NP phases, whereas significant differences in inspiratory fractions occurred much later (for FIO2) or never (for FICO2). The limiting factor in no air pocket conditions is excessive increase in work of breathing that induces increase in metabolism accompanied by higher oxygen consumption and carbon dioxide production. The presence of even a small air pocket reduces significantly the work of breathing.

  18. Evaluation of the Effectiveness of Pursed-Lip Breathing Education in Copd Patients

    Directory of Open Access Journals (Sweden)

    A Hajibagheri

    2006-07-01

    Full Text Available Introduction: Breathing rehabilitation techniques are designed to reduce symptoms, decrease disability, increase participation in physical and social activities, and improve the overall quality of life for individuals with chronic respiratory disease. However, the role of these techniques remains unclear. This study examined the effects of pursed-lip breathing (PLB education on the respiratory function, arterial blood gases and day to day life in patients with COPD. Methods: A before-after quasi-experimental research was conducted on 40 patients with COPD at Shahid Beheshti Hospital in Kashan. Spirogram and ABG were tested before and after three-months of PLB exercise and a questionnaire (AQ20 was used to assess day to day activities. Wilcoxon matched- pairs signed-rank and descriptive tests were used for statistical analysis of collected data. Results: The study showed that after three months breathing exercise, O2 saturation was significantly increased (P=0.002. Although there was an increase in PaO2 , it was not significant. In addition, a decrease in PaCO2 (P=0.014 and the respiration rate (P < 0.000 was observed. The level of activities of daily living was also increased (P < 0.000. Forced expired volume second one (FEV1% and forced vital capacity (FVC did not change. Conclusion: We conclude that pursed-lip breathing education can improve lung function, arterial blood gas levels and also the levels of day to day activities. Therefore, breathing exercises education should be a part of physiotherapy programs in COPD patients until improvement in the quality of their life.

  19. Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles

    Energy Technology Data Exchange (ETDEWEB)

    Atweh, Lamya A.; Dodd, Nicholas A.; Krishnamurthy, Ramkumar; Chu, Zili D. [Texas Children' s Hospital, EB Singleton Department of Pediatric Radiology, Cardiovascular Imaging, Houston, TX (United States); Pednekar, Amol [Philips Healthcare, Houston, TX (United States); Krishnamurthy, Rajesh [Texas Children' s Hospital, EB Singleton Department of Pediatric Radiology, Cardiovascular Imaging, Houston, TX (United States); Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Baylor College of Medicine, Department of Pediatrics, Houston, TX (United States)

    2016-05-15

    Breath-held two-dimensional balanced steady-state free precession cine acquisition (2-D breath-held SSFP), accelerated with parallel imaging, is the method of choice for evaluating ventricular function due to its superior blood-to-myocardial contrast, edge definition and high intrinsic signal-to-noise ratio throughout the cardiac cycle. The purpose of this study is to qualitatively and quantitatively compare the two different single-breath-hold 3-D cine SSFP acquisitions using 1) multidirectional sensitivity encoding (SENSE) acceleration factors (3-D multiple SENSE SSFP), and 2) k-t broad-use linear acceleration speed-up technique (3-D k-t SSFP) with the conventional 2-D breath-held SSFP in non-sedated asymptomatic volunteers and children with single ventricle congenital heart disease. Our prospective study was performed on 30 non-sedated subjects (9 healthy volunteers and 21 functional single ventricle patients), ages 12.5 +/- 2.8 years. Two-dimensional breath-held SSFP with SENSE acceleration factor of 2, eight-fold accelerated 3-D k-t SSFP, and 3-D multiple SENSE SSFP with total parallel imaging factor of 4 were performed to evaluate ventricular volumes and mass in the short-axis orientation. Image quality scores (blood myocardial contrast, edge definition and interslice alignment) and volumetric analysis (end systolic volume, end diastolic volume and ejection fraction) were performed on the data sets by experienced users. Paired t-test was performed to compare each of the 3-D k-t SSFP and 3-D multiple SENSE SSFP clinical scores against 2-D breath-held SSFP. Bland-Altman analysis was performed on left ventricle (LV) and single ventricle volumetry. Interobserver and intraobserver variability in volumetric measurements were determined using intraclass coefficients. The clinical scores were highest for the 2-D breath-held SSFP images. Between the two 3-D sequences, 3-D multiple SENSE SSFP performed better than 3-D k-t SSFP. Bland-Altman analysis for volumes

  20. Study on lung function test via tidal breathing in children under age of 5 years with bronchical asthma%潮气呼吸肺功能测定在5岁以下支气管哮喘儿童中的应用

    Institute of Scientific and Technical Information of China (English)

    安淑华; 李金英; 张剑霄; 王亚坤; 王艳艳; 郑博娟

    2011-01-01

    Objective To investigate the changes in large and small airway function of asthmatic children under age of 5 years by comparison of the lung function index of tidal breathing changes pre and post regular treatment. Methods Twenty asthmatic children under age of 5 years who were measured with tidal flow volume curve function test pre and post treatment, with 20 healthy children were enrolled as control. Results ( 1 )Comparison to healthy children, the index of large airway function ineluding VT/kg,TPTEF/TE, VPEF/VE,Ti/Te,TEF25% ,TEF50% in asthmatic children were significantly improved in acute stage, while the indexes were still lower than those in healthy children, Rr was higher than healthy children ( P < 0.05 ). There was no statistical significance in other indexes( P > 0. 05 ). ( 2 ) The indexes of TPTEF/TE, VPEF/VE, TEF50% , and TEF25% in asthmatic children were improved in recovery stage, while still lower than those in healthy children ( P <0. 05 ). There was no statistical significance in other indexes( P >0.05 ). ( 3 )Comparison to acute stage, the indexes of VT/kg, Ti/Te, TPTEF/TE, VPEF/VE in asthmatic children were improved( P <0. 05 ), while no statistical difference in other indexes( P > 0.05 ). Conclusion It demonstrated the value of lung function test via tidal breathing in evaluating airway function of asthmatic children under age of 5 years old.%目的 探讨潮气呼吸肺功能测定在5岁以下哮喘患儿中的应用价值.方法 对20例5岁以下儿童分别于哮喘急性期及缓解期行潮气呼吸肺功能测定,比较治疗前后肺功能指标变化.并与20例健康儿童进行对照.结果 (1)与健康对照组比较,急性期组VT/kg、TPTEF/TE、VPEF/VE、Ti/Te、TEF25%、TEF50%均较低,Rr升高(P0.05);(2)与健康对照组比较,缓解期组TPTEF/TE VPEF/VE、TEF50%、TEF25%有所恢复,但仍较低(P0.05);(3)与急性期组比较,缓解期组VT/kg、Ti/Te、TPTEF/TE、VPEF/VE均升高(P0.05).结论 潮气

  1. Patient-specific simulation of tidal breathing

    Science.gov (United States)

    Walters, M.; Wells, A. K.; Jones, I. P.; Hamill, I. S.; Veeckmans, B.; Vos, W.; Lefevre, C.; Fetitia, C.

    2016-03-01

    Patient-specific simulation of air flows in lungs is now straightforward using segmented airways trees from CT scans as the basis for Computational Fluid Dynamics (CFD) simulations. These models generally use static geometries, which do not account for the motion of the lungs and its influence on important clinical indicators, such as airway resistance. This paper is concerned with the simulation of tidal breathing, including the dynamic motion of the lungs, and the required analysis workflow. Geometries are based on CT scans obtained at the extremes of the breathing cycle, Total Lung Capacity (TLC) and Functional Residual Capacity (FRC). It describes how topologically consistent geometries are obtained at TLC and FRC, using a `skeleton' of the network of airway branches. From this a 3D computational mesh which morphs between TLC and FRC is generated. CFD results for a number of patient-specific cases, healthy and asthmatic, are presented. Finally their potential use in evaluation of the progress of the disease is discussed, focusing on an important clinical indicator, the airway resistance.

  2. Exhaled Breath Condensate: Technical and Diagnostic Aspects

    Directory of Open Access Journals (Sweden)

    Efstathia M. Konstantinidi

    2015-01-01

    Full Text Available Purpose. The aim of this study was to evaluate the 30-year progress of research on exhaled breath condensate in a disease-based approach. Methods. We searched PubMed/Medline, ScienceDirect, and Google Scholar using the following keywords: exhaled breath condensate (EBC, biomarkers, pH, asthma, gastroesophageal reflux (GERD, smoking, COPD, lung cancer, NSCLC, mechanical ventilation, cystic fibrosis, pulmonary arterial hypertension (PAH, idiopathic pulmonary fibrosis, interstitial lung diseases, obstructive sleep apnea (OSA, and drugs. Results. We found 12600 related articles in total in Google Scholar, 1807 in ScienceDirect, and 1081 in PubMed/Medline, published from 1980 to October 2014. 228 original investigation and review articles were eligible. Conclusions. There is rapidly increasing number of innovative articles, covering all the areas of modern respiratory medicine and expanding EBC potential clinical applications to other fields of internal medicine. However, the majority of published papers represent the results of small-scale studies and thus current knowledge must be further evaluated in large cohorts. In regard to the potential clinical use of EBC-analysis, several limitations must be pointed out, including poor reproducibility of biomarkers and absence of large surveys towards determination of reference-normal values. In conclusion, contemporary EBC-analysis is an intriguing achievement, but still in early stage when it comes to its application in clinical practice.

  3. Screening Sleep Disordered Breathing in Stroke Unit

    Directory of Open Access Journals (Sweden)

    Kirsi Väyrynen

    2014-01-01

    Full Text Available In acute stroke, OSA has been found to impair rehabilitation and increase mortality but the effect of central apnea is more unclear. The aim of the present study was to evaluate the feasibility of using limited ambulatory recording system (sleep mattress to evaluate nocturnal breathing and EOG-electrodes for sleep staging in sleep disordered breathing (SDB diagnostics in mild acute cerebral ischemia patients and to discover the prevalence of various SDB-patterns among these patients. 42 patients with mild ischemic stroke or transient ischemic attack were studied. OSA was found in 22 patients (52.4%. Central apnea was found in two patients (4.8% and sustained partial obstruction in only one patient (2.4%. Sleep staging with EOG-electrodes only yielded a similar outcome as scoring with standard rules. OSA was found to be common even after mild stroke. Its early diagnosis and treatment would be favourable in order to improve recovery and reduce mortality. Our results suggest that OSA can be assessed by a limited recording setting with EOG-electrodes, sleep mattress, and pulse oximetry.

  4. Epiglottic movements during breathing in humans

    Science.gov (United States)

    Amis, T C; O'Neill, N; Di Somma, E; Wheatley, J R

    1998-01-01

    Using X-ray fluoroscopy we measured antero-posterior (A–P) and cranio-caudal (C–C) displacements of the epiglottic tip (ET), corniculate cartilage and hyoid bone in seven seated, normal human subjects (age 34 ± 3 years; mean ±s.e.m.; 4 males, 3 females) breathing via a nasal mask or mouthpiece with (RL) and without (UB) a fixed resistive load.During UB, via either mouth or nose, there were no significant A-P ET movements. During RL via the nose the ET at peak expiratory flow was 2.6 ± 1.3 mm cranial to its position at peak inspiratory flow (P <0.05, ANOVA). C–C movements of the ET correlated strongly with C-C movements of the corniculate cartilage and hyoid bone.The ET, corniculate cartilage and hyoid bone (at zero airflow) were situated more caudally during oral UB than for any other condition.When present, epiglottic movements during breathing do not appear to be independent of those of the larynx and hyoid. Furthermore, epiglottic position may be related to the level of upper airway resistance. PMID:9729637

  5. Effects of Piracetam on Pediatric Breath Holding Spells: A Randomized Double Blind Controlled Trial

    Directory of Open Access Journals (Sweden)

    Ali ABBASKHANIAN

    2013-01-01

    of breath holding spells. J Postgrad Med Instit. 2005;19(2:171-4.Di lanni M, Wilsher CR, Blank MS, Conners CK, Chase CH, Funkenstein HH et al. The effects of piracetam in children with dyslexia. J Clin Psychopharmacol. 1985 Oct;5(5:272-8.Wilsher CR, Bennett D, Chase CH, Conners CK, Dilanni M, Feagans L et al. Piracetam and dyslexia: effects on reading tests. J Clin Psychopharmacol. 1987 Aug;7(4:230-7.DiMario FJ Jr, Sarfarazi M. Family pedigree analysis of children with severe breath-holding spells. J Pediatr. 1997 Apr;130(4:647-51.Winnicka K, Tomasiak M, Bielawska A. Piracetam-an old drug with novel properties. Acta Pol Pharm. 2005 Sep-Oct:62(5:405-9.Winblad, B. Piracetam: a review of pharmacological properties and clinical uses. CNS drug rev. 2005 Summer:11(2:169-82.

  6. Definition, discrimination, diagnosis and treatment of central breathing disturbances during sleep

    NARCIS (Netherlands)

    Randerath, Winfried; Verbraecken, Johan; Andreas, Stefan; Arzt, Michael; Bloch, Konrad E; Brack, Thomas; Buyse, Bertien; De Backer, Wilfried; Eckert, Danny Joel; Grote, Ludger; Hagmeyer, Lars; Hedner, Jan; Jennum, Poul; La Rovere, Maria Teresa; Miltz, Carla; McNicholas, Walter T; Montserrat, Josep; Naughton, Matthew; Pepin, Jean-Louis; Pevernagie, Dirk; Sanner, Bernd; Testelmans, Dries; Tonia, Thomy; Vrijsen, Bart; Wijkstra, Peter; Levy, Patrick

    2016-01-01

    The complexity of central breathing disturbances during sleep has become increasingly obvious. They present as central sleep apnoeas (CSAs) and hypopnoeas, periodic breathing with apnoeas, or irregular breathing in patients with cardiovascular, other internal or neurological disorders, and can emerg

  7. Definition, discrimination, diagnosis and treatment of central breathing disturbances during sleep

    DEFF Research Database (Denmark)

    Randerath, Winfried; Verbraecken, Johan; Andreas, Stefan;

    2017-01-01

    The complexity of central breathing disturbances during sleep has become increasingly obvious. They present as central sleep apnoeas (CSAs) and hypopnoeas, periodic breathing with apnoeas, or irregular breathing in patients with cardiovascular, other internal or neurological disorders, and can em...

  8. Effect of Level and Downhill Running on Breathing Efficiency

    Directory of Open Access Journals (Sweden)

    Matthew D. Cook

    2015-01-01

    Full Text Available Ventilatory equivalents for oxygen and carbon dioxide are physiological measures of breathing efficiency, and are known to be affected by the intensity and mode of exercise. We examined the effect of level running (gradient 0% and muscle-damaging downhill running (−12%, matched for oxygen uptake, on the ventilatory equivalents for oxygen ( and carbon dioxide (. Nine men (27 ± 9 years, 179 ± 7 cm, 75 ± 12 kg, : 52.0 ± 7.7 mL·kg−1·min−1 completed two 40-min running bouts (5 × 8-min with 2-min inter-bout rest, one level and one downhill. Running intensity was matched at 60% of maximal metabolic equivalent. Maximal isometric force of m.quadriceps femoris was measured before and after the running bouts. Data was analyzed with 2-way ANOVA or paired samples t-tests. Running speed (downhill: 13.5 ± 3.2, level: 9.6 ± 2.2 km·h−1 and isometric force deficits (downhill: 17.2 ± 7.6%, level: 2.0 ± 6.9% were higher for downhill running. Running bouts for level and downhill gradients had , heart rates and respiratory exchange ratio values that were not different indicating matched intensity and metabolic demands. During downhill running, the , (downhill: 29.7 ± 3.3, level: 27.2 ± 1.6 and  (downhill: 33.3 ± 2.7, level: 30.4 ± 1.9 were 7.1% and 8.3% higher (p < 0.05 than level running. In conclusion, breathing efficiency appears lower during downhill running (i.e., muscle-damaging exercise compared to level running at a similar moderate intensity.

  9. Health, social and economical consequences of sleep-disordered breathing

    DEFF Research Database (Denmark)

    Jennum, Poul; Kjellberg, Jakob

    2011-01-01

    The objective direct and indirect costs of sleep-disordered breathing (snoring, sleep apnoea (SA) and obesity hypoventilation syndrome (OHS)) and the treatment are incompletely described.......The objective direct and indirect costs of sleep-disordered breathing (snoring, sleep apnoea (SA) and obesity hypoventilation syndrome (OHS)) and the treatment are incompletely described....

  10. Symptoms of sleep disordered breathing and risk of cancer

    DEFF Research Database (Denmark)

    Christensen, Anne Sofie; Clark, Alice Jessie; Salo, Paula;

    2013-01-01

    Sleep disordered breathing (SDB) has been associated with oxidative stress, inflammation, and altered hormonal levels, all of which could affect the risk of cancer. The aim of the study is to examine if symptoms of SDB including snoring, breathing cessations, and daytime sleepiness affect...

  11. 46 CFR 154.1852 - Air breathing equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air...

  12. Measurement of Personal Exposure Using a Breathing Thermal Manikin

    DEFF Research Database (Denmark)

    Brohus, Henrik

    In this paper personal exposure measurements are performed by means of the Breathing Thermal Manikin. Contaminant concentration is measured in a number of locations in the breathing zone and in the inhaled air. Two cases are investigated: exposure to different contaminant sources in a displacement...

  13. A Raman cell based on hollow core photonic crystal fiber for human breath analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Kam Kong; Zeng, Haishan, E-mail: hzeng@bccrc.ca [Imaging Unit – Integrative Oncology Department, British Columbia Cancer Agency Research Centre, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3, Canada and Medical Physics Program – Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, British Columbia V6T 1Z1 (Canada); Short, Michael; Lam, Stephen; McWilliams, Annette [Imaging Unit – Integrative Oncology Department, British Columbia Cancer Agency Research Centre, 675 West 10th Avenue, Vancouver, British Columbia V5Z 1L3 (Canada)

    2014-09-15

    Purpose: Breath analysis has a potential prospect to benefit the medical field based on its perceived advantages to become a point-of-care, easy to use, and cost-effective technology. Early studies done by mass spectrometry show that volatile organic compounds from human breath can represent certain disease states of our bodies, such as lung cancer, and revealed the potential of breath analysis. But mass spectrometry is costly and has slow-turnaround time. The authors’ goal is to develop a more portable and cost effective device based on Raman spectroscopy and hollow core-photonic crystal fiber (HC-PCF) for breath analysis. Methods: Raman scattering is a photon-molecular interaction based on the kinetic modes of an analyte which offers unique fingerprint type signals that allow molecular identification. HC-PCF is a novel light guide which allows light to be confined in a hollow core and it can be filled with a gaseous sample. Raman signals generated by the gaseous sample (i.e., human breath) can be guided and collected effectively for spectral analysis. Results: A Raman-cell based on HC-PCF in the near infrared wavelength range was developed and tested in a single pass forward-scattering mode for different gaseous samples. Raman spectra were obtained successfully from reference gases (hydrogen, oxygen, carbon dioxide gases), ambient air, and a human breath sample. The calculated minimum detectable concentration of this system was ∼15 parts per million by volume, determined by measuring the carbon dioxide concentration in ambient air via the characteristic Raman peaks at 1286 and 1388 cm{sup −1}. Conclusions: The results of this study were compared to a previous study using HC-PCF to trap industrial gases and backward-scatter 514.5 nm light from them. The authors found that the method presented in this paper has an advantage to enhance the signal-to-noise ratio (SNR). This SNR advantage, coupled with the better transmission of HC-PCF in the near-IR than in the

  14. Background levels of carbon-13 reduced in breath and stool by new infant formula.

    Science.gov (United States)

    Boutton, T W; Hopkinson, J M; Benton, D A; Klein, P D

    1988-01-01

    Studies of the absorption and bioavailability of nutrients naturally enriched with 13C require accurate measurements of small increases of 13C in respiratory CO2 and stool carbon. The sensitivity of these measurements would be increased if the natural background of 13C in these excreta were reduced. We have developed a 13C-depleted infant formula based on lactose, whey, and casein from New Zealand cows that consume only C3 vegetation naturally low in 13C. This formula, designated CNRC3, was produced by a commercial infant formula manufacturer and was comparable with a 60:40 whey/casein product. To test the ability of the formula to reduce baseline levels of 13C in infant excreta, 10 formula-fed infants 28-60 days old and free of metabolic disorders were enrolled in the 9-day study. Two stool samples were collected daily. Infants received their usual formula on days 1 and 2 and were switched to CNRC3 formula for days 3-9. On days 2 and 9, seven breath samples were collected at 30-min intervals with a face mask. Breath and stool samples were analyzed for 13C content by gas isotope ratio mass spectrometry. Infants consuming their commercial formula had breath delta 13C values of -21.1 +/- 0.6% over the 3-h collection period; stool values were -22.9 +/- 0.4%. After 7 days on the CNRC3 formula, delta 13C values of breath declined by 5.6% to -26.7 +/- 0.7%; stool values declined by 3.0% to -25.6 +/- 0.5%. The reduced background of 13C achieved by the CNRC3 formula can improve resolution of excess 13C from naturally enriched substrates in infant breath by approximately 50% and in stool by approximately 30%.

  15. Craniofacial changes and symptoms of sleep-disordered breathing in healthy children

    Directory of Open Access Journals (Sweden)

    Maria Christina Thomé Pacheco

    2015-06-01

    Full Text Available INTRODUCTION: The main cause of mouth breathing and sleep-disordered breathing (SDB in childhood is associated with upper airway narrowing to varying degrees. OBJECTIVE: The aim of this study was to assess the prevalence of morphological and functional craniofacial changes and the main clinical symptoms of SDB in healthy children. METHODS: A cross-sectional observational study was conducted. A sample comprising 687 healthy schoolchildren, aged 7-12 years old and attending public schools, was assessed by medical history, clinical medical and dental examination, and respiratory tests. The self-perceived quality of life of mouth breathing children was obtained by a validated questionnaire. RESULTS: Out of the total sample, 520 children were nose breathers (NB while 167 (24.3% were mouth breathers (MB; 32.5% had severe hypertrophy of the palatine tonsils, 18% had a Mallampati score of III or IV, 26.1% had excessive overjet and 17.7% had anterior open bite malocclusion. Among the MB, 53.9% had atresic palate, 35.9% had lip incompetence, 33.5% reported sleepiness during the day, 32.2% often sneezed, 32.2% had a stuffy nose, 19.6% snored, and 9.4% reported having the feeling to stop breathing while asleep. However, the self-perception of their quality of life was considered good. CONCLUSION: High prevalence of facial changes as well as signs and symptoms of mouth breathing were found among health children, requiring early diagnosis and treatment to reduce the risk of SDB.

  16. Effects of ozone exposure: a comparison between oral and nasal breathing

    Energy Technology Data Exchange (ETDEWEB)

    Hynes, B.; Silverman, F.; Cole, P.; Corey, P.

    1988-09-01

    Mode of inhalation, by nose or by mouth, as a determinant of pulmonary toxicity to acute inhalant exposure has been investigated incompletely. This communication addresses whether there are significant differences in toxic pulmonary responses to acute ozone (O/sub 3/) exposure between differing modes of inhalation (nasal vs. oral breathing). Changes in the results of pulmonary function tests and symptomatology of healthy young adults were compared following both exclusive nose and exclusive mouth breathing during a 30-min exposure to approximately 0.4 ppm O/sub 3/ under conditions of moderate continuous exercise. In this single-blind, randomized, crossover study, no significant differences in either the results of pulmonary function tests or in symptomatology were found between the two modes of inhalation.

  17. Sleep-disordered breathing and stroke.

    Science.gov (United States)

    Ali, Latisha K; Avidan, Alon Y

    2008-01-01

    Sleep and stroke have an important and fascinating interaction. Patients with sleep-disordered breathing present with cardiovascular heart disease, cognitive decline, and increased risk of stroke. Stroke adversely affects sleep and factors such as prolonged immobilization, chronic pain, nocturnal hypoxia, and depression, which can also adversely impact sleep quality. Obstructive sleep apnea (OSA), one of the most common and serious sleep disturbances, manifests itself in almost 50% of all stroke patients. Sleep apnea patients who experience a stroke may be at a greater impairment in their rehabilitation potential and have increased risk of secondary stroke and mortality. Given these factors, the practicing neurologist should possess the skills to appropriately recognize, rapidly diagnose, and properly manage stroke patients with OSA.

  18. Oral breathing: new early treatment protocol

    Directory of Open Access Journals (Sweden)

    Gloria Denotti

    2014-01-01

    Full Text Available Oral breathing is a respiratory dysfunction that affects approximately 10-15% of child population. It is responsable of local effects and systemic effects, both immediate and long-term. They affect the growth of the subject and his physical health in many ways: pediatric, psycho-behavioral and cognitive. The etiology is multifactorial. It’s important the establishment of a vicious circle involving more areas and it is essential to stop it as soon as possible. In order to correct this anomaly, the pediatric dentist must be able to make a correct diagnosis to treat early the disfunction and to avoid the onset of cascade mechanisms. Who plays a central role is the pediatrician who first and frequently come into contact with little patients. He can identify the anomalies, and therefore collaborate with other specialists, including the dentist. The key aspect that guides us in the diagnosis, and allows us to identify the oral respirator, is the “adenoid facies”. The purpose of the study is to highlight the importance and benefits of an early and multidisciplinary intervention (pediatric, orthopedic-orthodontic-functional. A sample of 20 patients was selected with the following inclusion criteria: mouth breathing, transverse discrepancy > 4 mm, early mixed dentition, central and lateral permenent incisors, overjet increased, lip and nasal incompetence, snoring and/or sleep apnea episodes. The protocol of intervention includes the use of the following devices and procedures: a maxillary rapid expander (to correct the transverse discrepancy, to increase the amplitude of the upper respiratory airway and to reduce nasal resistances tract in association with myo-functional devices (nasal stimulator and oral obturator. They allow the reconstruction of a physiological balance between the perioral musculature and tongue, the acquisition of nasal and lips competence and the reduction of overjet. This protocol speeds up and stabilizes the results. The

  19. Breathing abnormalities in a female mouse model of Rett syndrome.

    Science.gov (United States)

    Johnson, Christopher M; Cui, Ningren; Zhong, Weiwei; Oginsky, Max F; Jiang, Chun

    2015-09-01

    Rett syndrome (RTT) is a female neurodevelopmental disease with breathing abnormalities. To understand whether breathing defects occur in the early lives of a group of female Mecp2(+/-) mice, a mouse model of RTT, and what percentage of mice shows RTT-like breathing abnormality, breathing activity was measured by plethysmography in conscious mice. Breathing frequency variation and central apnea in a group of Mecp2(+/-) females displayed a distribution pattern similar to Mecp2(-/Y) males, while the rest resembled the wild-type mice. Similar results were obtained using the k-mean clustering statistics analysis. With two independent methods, about 20% of female Mecp2(+/-) mice showed RTT-like breathing abnormalities that began as early as 3 weeks of age in the Mecp2(+/-) mice, and were suppressed with 3% CO2. The finding that only a small proportion of Mecp2(+/-) mice develops RTT-like breathing abnormalities suggests incomplete allele inactivation in the RTT-model Mecp2(+/-) mice.

  20. Voluntary control of breathing does not alter vagal modulation of heart rate

    Science.gov (United States)

    Patwardhan, A. R.; Evans, J. M.; Bruce, E. N.; Eckberg, D. L.; Knapp, C. F.

    1995-01-01

    Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.

  1. Reference values of exhaled nitric oxide in healthy children 1-5 years using off-line tidal breathing

    NARCIS (Netherlands)

    Heijden, H.H. van der; Brouwer, M.L.; Hoekstra, F.; Pol, P. van der; Merkus, P.J.F.M.

    2014-01-01

    Measurement of the fraction of exhaled nitric oxide (FeNO) is a useful test to diagnose and/or monitor eosinophilic airway inflammation. The off-line tidal breathing method is used for measurements in young children, but reference values for preschool children are scarce. The objective of this study

  2. The clinical significance of testing LTB4 and TNF-α in exhaled breath condensate and serum of oatients with OSAHS%OSAHS患者呼出气冷凝液和血清中LTB4和TNF-α检测的临床意义

    Institute of Scientific and Technical Information of China (English)

    姚苏梅; 陶一江; 丁松云; 朱杰; 陈建荣

    2011-01-01

    Objective To investigate the clinical significance of testing inflammation factor in exhaled breath condensate (EBC)of patients with OSAHS.Methods 50 patients with OSAHS diagnosed by PSG (30 patients with treatment for about 3 months) and 30 age matched controls were enrolled in the study.Leukotriene B4 and tumor necrosis factor α levels were measured by enzyme linked immunesothent assay.Results ①The levels of LTB and TNF-α in EBC and serum with OSAHS were significanfiy higher than that in the control group (all P <0.05 ) ②LTB4 and TNF-α levels in EBC were positively correlated with AHI and negatively correlated with LSpO2 and MSpO2.③During the period of three months'treatment there was such a further significant decrease in LTB4 and TNF-α in EBC in 30 patients with OSAHS.Conclusions There was important clinical significance of detection of inflammation factors in EBC in monitoring the severity and treatment of OSAHS.%目的 探讨阻塞性睡眠呼吸暂停低通气综合征患者呼出气冷凝液(EBC)中炎症因子检测的临床意义.方法 选择经多导睡眠监测确诊的OSAHS患者50例和正常对照30例,采用酶联免疫技术分别检测EBC和血清中白三烯B4、肿瘤坏死因子-α的浓度,30例OSAHS患者经治疗三月后再次检测.结果 ①OSAHS组EBC和血清中LTB4及TNF-α水平均明显高于对照组,P均<0.05.②OSAHS患者EBC中LTB4和TNF-α水平与AHI正相关;与睡眠中LSpO2、MSpO2负相关.③OSAHS患者治疗后EBC中LTB4和TNF-α水平较治疗前下降,差异有统计学意义,P<0.01.结论 EBC中炎症因子检测对判断OSAHS患者病情严重程度和治疗效果具重要意义.

  3. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, Nilesh N., E-mail: nmistry@som.umaryland.edu [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Diwanji, Tejan; Shi, Xiutao [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Pokharel, Sabin [Morgan State University, Baltimore, Maryland (United States); Feigenberg, Steven [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Scharf, Steven M. [Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland (United States); D' Souza, Warren D. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States)

    2013-11-15

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1 session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R{sup 2} of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic

  4. Chronic adaptations of lung function in breath-hold diving fishermen

    Directory of Open Access Journals (Sweden)

    Cristiane Diniz

    2014-04-01

    Full Text Available Objectives: The aim of this study was to verify and analyze the existence of chronic adaptations of lung function in freediving fishermen whose occupation is artisanal fishing. Material and Methods: This was a cross-sectional study involving 11 breath-hold diving fishermen and 10 non-breath-hold diving fishermen (control from the village of Bitupitá in the municipality of Barroquinha (Ceará - Brazil. Anthropometric measurements, chest and abdominal circumferences as well as spirometric and respiratory muscle strength tests were conducted according to the specifications of the American Thoracic Society/European Respiratory Society (ATS/ERS. In order to compare the measured values versus the predicted values, Student t test was used in the case of parametric test and Wilcoxon test in the case of nonparametric test. To compare the inter-group means Student t test was used for parametric test and Mann-Whitney test for the nonparametric one. The level of significance was set at α = 5%. Results: The forced vital capacity (FVC (4.9±0.6 l vs. 4.3±0.4 l and forced expiratory volume in 1 s (FEV1 (4.0±0.5 l vs. 3.6±0.3 l were, respectively, higher in the group of divers compared to the control group (p ≤ 0.05. Furthermore, in the group of free divers, the measured FVC, FEV1 and FEV1/FVC ratios were significantly greater than the predicted ones. No differences were found between the measured respiratory pressures. Conclusions: These results indicate that breath-hold diving seems to produce chronic adaptations of the respiratory system, resulting in elevated lung volumes with no airway obstruction.

  5. Whole-heart magnetic resonance coronary angiography with multiple breath-holds and automatic breathing-level tracking

    Science.gov (United States)

    Kuhara, Shigehide; Ninomiya, Ayako; Okada, Tomohisa; Kanao, Shotaro; Kamae, Toshikazu; Togashi, Kaori

    2010-05-01

    Whole-heart (WH) magnetic resonance coronary angiography (MRCA) studies are usually performed during free breathing while monitoring the position of the diaphragm with real-time motion correction. However, this results in a long scan time and the patient's breathing pattern may change, causing the study to be aborted. Alternatively, WH MRCA can be performed with multiple breath-holds (mBH). However, one problem in the mBH method is that patients cannot hold their breath at the same position every time, leading to image degradation. We have developed a new WH MRCA imaging method that employs both the mBH method and automatic breathing-level tracking to permit automatic tracking of the changes in breathing or breath-hold levels. Evaluation of its effects on WH MRCA image quality showed that this method can provide high-quality images within a shorter scan time. This proposed method is expected to be very useful in clinical WH MRCA studies.

  6. Understanding the Potential of WO3 Based Sensors for Breath Analysis

    Science.gov (United States)

    Staerz, Anna; Weimar, Udo; Barsan, Nicolae

    2016-01-01

    Tungsten trioxide is the second most commonly used semiconducting metal oxide in gas sensors. Semiconducting metal oxide (SMOX)-based sensors are small, robust, inexpensive and sensitive, making them highly attractive for handheld portable medical diagnostic detectors. WO3 is reported to show high sensor responses to several biomarkers found in breath, e.g., acetone, ammonia, carbon monoxide, hydrogen sulfide, toluene, and nitric oxide. Modern material science allows WO3 samples to be tailored to address certain sensing needs. Utilizing recent advances in breath sampling it will be possible in the future to test WO3-based sensors in application conditions and to compare the sensing results to those obtained using more expensive analytical methods. PMID:27801881

  7. sLORETA intracortical lagged coherence during breath counting in meditation-naïve participants

    Directory of Open Access Journals (Sweden)

    Patricia eMilz

    2014-05-01

    Full Text Available We investigated brain functional connectivity comparing no-task resting to breath counting (a meditation exercise but given as task without referring to meditation. Functional connectivity computed as EEG coherence between head-surface data suffers from localization ambiguity, reference dependence, and overestimation due to volume conduction. Lagged coherence between intracortical model sources addresses these criticisms. With this analysis approach, experienced meditators reportedly showed reduced coherence during meditation, meditation-naïve participants have not yet been investigated. 58-channel EEG from 23 healthy, right-handed, meditation-naïve males during resting [3 runs] and breath counting [2 runs] was computed into sLORETA time series of intracortical electrical activity in 19 regions of interest corresponding to the cortex underlying 19 scalp electrode sites, for each of the 8 independent EEG frequency bands covering 1.5-44 Hz. Intracortical lagged coherences and head-surface conventional coherences were computed between the 19 regions/sites. During breath counting compared to resting, paired t-tests corrected for multiple testing revealed 4 significantly lower intracortical lagged coherences, but 4 significantly higher head-surface conventional coherences. Lowered intracortical lagged coherences involved left BA 10 and right BAs 3, 10, 17, 40. In conclusion, intracortical lagged coherence can yield results that are inverted to those of head-surface conventional coherence. The lowered functional connectivity between cognitive control areas and sensory perception areas during meditation-type breath counting compared to resting conceivably reflects the attention to a bodily percept without cognitive reasoning. The reductions in functional connectivity were similar but not as widespread as the reductions reported during meditation in experienced meditators.

  8. Syllable-Related Breathing in Infants in the Second Year of Life

    Science.gov (United States)

    Parham, Douglas F.; Buder, Eugene H.; Oller, D. Kimbrough; Boliek, Carol A.

    2011-01-01

    Purpose: This study explored whether breathing behaviors of infants within the 2nd year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Method: Vocalizations and breathing kinematics of 9 infants between 53 and 90 weeks of age were recorded. A strict selection…

  9. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS.”...

  10. Evaluation of breathing patterns for respiratory-gated radiation therapy using the respiration regularity index

    Science.gov (United States)

    Cheong, Kwang-Ho; Lee, MeYeon; Kang, Sei-Kwon; Yoon, Jai-Woong; Park, SoAh; Hwang, Taejin; Kim, Haeyoung; Kim, KyoungJu; Han, Tae Jin; Bae, Hoonsik

    2015-01-01

    suitable for respiratory-gated radiation therapy (RGRT). Fluctuations in the breathing cycle and the amplitude were especially determinative of ρ. If the respiration regularity of a patient's first session was known, it could be estimated through subsequent sessions. Notably, the breathing patterns of the lung cancer patients were more irregular than those of the liver cancer patients. Respiration regularity could be objectively determined by using a composite index, ρ. Such a single-index testing of respiration regularity can facilitate determination of RGRT availability in clinical settings, especially for free-breathing cases.

  11. Evaluation of pulmonary function using single-breath-hold dual-energy computed tomography with xenon

    Science.gov (United States)

    Kyoyama, Hiroyuki; Hirata, Yusuke; Kikuchi, Satoshi; Sakai, Kosuke; Saito, Yuriko; Mikami, Shintaro; Moriyama, Gaku; Yanagita, Hisami; Watanabe, Wataru; Otani, Katharina; Honda, Norinari; Uematsu, Kazutsugu

    2017-01-01

    Abstract Xenon-enhanced dual-energy computed tomography (xenon-enhanced CT) can provide lung ventilation maps that may be useful for assessing structural and functional abnormalities of the lung. Xenon-enhanced CT has been performed using a multiple-breath-hold technique during xenon washout. We recently developed xenon-enhanced CT using a single-breath-hold technique to assess ventilation. We sought to evaluate whether xenon-enhanced CT using a single-breath-hold technique correlates with pulmonary function testing (PFT) results. Twenty-six patients, including 11 chronic obstructive pulmonary disease (COPD) patients, underwent xenon-enhanced CT and PFT. Three of the COPD patients underwent xenon-enhanced CT before and after bronchodilator treatment. Images from xenon-CT were obtained by dual-source CT during a breath-hold after a single vital-capacity inspiration of a xenon–oxygen gas mixture. Image postprocessing by 3-material decomposition generated conventional CT and xenon-enhanced images. Low-attenuation areas on xenon images matched low-attenuation areas on conventional CT in 21 cases but matched normal-attenuation areas in 5 cases. Volumes of Hounsfield unit (HU) histograms of xenon images correlated moderately and highly with vital capacity (VC) and total lung capacity (TLC), respectively (r = 0.68 and 0.85). Means and modes of histograms weakly correlated with VC (r = 0.39 and 0.38), moderately with forced expiratory volume in 1 second (FEV1) (r = 0.59 and 0.56), weakly with the ratio of FEV1 to FVC (r = 0.46 and 0.42), and moderately with the ratio of FEV1 to its predicted value (r = 0.64 and 0.60). Mode and volume of histograms increased in 2 COPD patients after the improvement of FEV1 with bronchodilators. Inhalation of xenon gas caused no adverse effects. Xenon-enhanced CT using a single-breath-hold technique depicted functional abnormalities not detectable on thin-slice CT. Mode, mean, and volume of HU histograms of xenon images

  12. COPD: When You Learn More, You'll Breathe Better

    Science.gov (United States)

    Skip Navigation Bar Home Current Issue Past Issues COPD: When You Learn More, You'll Breathe Better ... Trial to Look at Home Oxygen Therapy for COPD The National Heart, Lung, and Blood Institute (NHLBI) ...

  13. Taking Her Breath Away: The Rise of COPD in Women

    Science.gov (United States)

    ... Disparities Taking Her Breath Away: The Rise of COPD in Women Disparities in Lung Health Series More ... the U.S. live with chronic obstructive pulmonary disease (COPD), which includes chronic bronchitis and emphysema. Millions more ...

  14. Bounded Gain of Energy on the Breathing Circle Billiard

    CERN Document Server

    Oliffson-Kamphorst, S; Kamphorst, Sylvie Oliffson; Carvalho, Sonia Pinto de

    1998-01-01

    The Breathing Circle is a 2-dimensional generalization of the Fermi Accelerator. It is shown that the billiard map associated to this model has invariant curves in phase space, implying that any particle will have bounded gain of energy.

  15. Exhaled breath condensate: methodological recommendations and unresolved questions.

    NARCIS (Netherlands)

    Horvath, I.; Hunt, J.; Barnes, P.J.; Alving, K.; Antczak, A.; Baraldi, E.; Becher, G.; Beurden, W.J.C van; Corradi, M.; Dekhuijzen, P.N.R.; Dweik, R.A.; Dwyer, T.; Effros, R.; Erzurum, S.; Gaston, B.; Gessner, C.; Greening, A.; Ho, L.P.; Hohlfeld, J.; Jobsis, Q.; Laskowski, D.; Loukides, S.; Marlin, D.; Montuschi, P.; Olin, A.C.; Redington, A.E.; Reinhold, P.; Rensen, E.L. van; Rubinstein, I.; Silkoff, P.; Toren, K.; Vass, G.; Vogelberg, C.; Wirtz, H.

    2005-01-01

    Collection of exhaled breath condensate (EBC) is a noninvasive method for obtaining samples from the lungs. EBC contains large number of mediators including adenosine, ammonia, hydrogen peroxide, isoprostanes, leukotrienes, nitrogen oxides, peptides and cytokines. Concentrations of these mediators a

  16. Training Studies with Compressed Air Breathing Apparatus – Methodology, Exercises

    Directory of Open Access Journals (Sweden)

    Buks Roberts

    2015-11-01

    Full Text Available The current article describes topics ranging from the respiratory physiology and the structure of compressed air breathing apparatus to the performance of practical training exercises in an unbreathable environment (hereinafter referred to as UE.

  17. Atmospheric Breathing Electric Thruster for Planetary Exploration Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This study will investigate the development of an atmosphere-breathing electric propulsion solar-powered vehicle to explore planets such as Mars. The vehicle would...

  18. CO2 Washout Capability with Breathing Manikin Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The intent of this particular project was to perform the following:Provide a breathing capability to be integrated into existing EC5 Ventilation Lab Suited...

  19. Fear of suffocation alters respiration during obstructed breathing.

    Science.gov (United States)

    Pappens, Meike; Smets, Elyn; Van Den Bergh, Omer; Van Diest, Ilse

    2012-06-01

    We aimed to investigate whether fear of suffocation predicts healthy persons' respiratory and affective responses to obstructed breathing as evoked by inspiratory resistive loads. Participants (N = 27 women, ages between 18 and 21 years) completed the Fear of Suffocation scale and underwent 16 trials in which an inspiratory resistive load of 15 cmH(2)O/l/s (small) or 40 cmH(2)O/l/s (large) was added to the breathing circuit for 40 s. Fear of suffocation was associated with higher arousal ratings for both loads. Loaded breathing was associated with a decrease in minute ventilation, but progressively less so for participants scoring higher on fear of suffocation when breathing against the large load. The present findings document a potentially panicogenic mechanism that may maintain and worsen respiratory discomfort in persons with fear of suffocation.

  20. Cardiac output in exercise by impedance cardiography during breath holding and normal breathing.

    Science.gov (United States)

    Du Quesnay, M C; Stoute, G J; Hughson, R L

    1987-01-01

    Estimation of cardiac output by impedance cardiography (QZ) in exercise during normal breathing (NB) has been limited by motion artifact. Our objective was to obtain readable impedance cardiograms on five subjects during upright cycle exercise at 0, 50, 100, 150, and 200 W to permit comparisons of QZ during NB, expiratory breath hold (EXP) and inspiratory breath hold (INSP). Q was also determined using an equilibration CO2 rebreathing method [Q(RB)]. QZ during NB exceeded EXP QZ at 100, 150, and 200 W, and exceeded INSP QZ at 100 W (P less than 0.05). The low EXP QZ values were due to a significantly lower stroke volume at 100, 150, and 200 W (P less than 0.05). For the INSP QZ at 100 W, heart rate was lower than during EXP (P less than 0.05). Regression of QZ (NB) against Q(RB) resulted in a linear relationship (r = 0.93) over the range of Q = 7-26 1/min. The slope of the regression differed significantly from 1.0 (P less than 0.05). We conclude that QZ values obtained during EXP or INSP should not be assumed to represent QZ during NB, at least at work rates greater than 50 W. A consequence of the linear relationship between QZ(NB) and Q(RB) over the range of 0-200 W is that estimates of CO2 rebreathing cardiac output can be obtained by impedance cardiography if QZ is adjusted using an appropriate empirical factor.

  1. Insomnia and sleep-related breathing disorders.

    Science.gov (United States)

    Wickwire, Emerson M; Collop, Nancy A

    2010-06-01

    Insomnia disorder and obstructive sleep apnea are the two most common sleep disorders among adults. Historically, these conditions have been conceptualized as orthogonal, or insomnia has been considered a symptom of sleep apnea. Insomnia researchers have sought to exclude participants at risk for sleep-related breathing disorders (SRBD), and vice versa. In recent years, however, there has been a growing recognition of co-occurring insomnia disorder and SRBD and interest in the prevalence, consequences, and treatment of the two conditions when they co-occur. Although plagued by inconsistent diagnostic criteria and operational definitions, evidence from clinical and research samples consistently suggests high rates of comorbidity between the two disorders. More important, insomnia disorder and SRBD have additive negative effects. To date, only a few studies have explored the combined or sequential treatment of the conditions. Results support the importance of an integrated, interdisciplinary approach to sleep medicine. This article reviews the empirical literature to date and provides clinical recommendations as well as suggestions for future research.

  2. FBG sensor of breathing encapsulated into polydimethylsiloxane

    Science.gov (United States)

    Fajkus, Marcel; Nedoma, Jan; Siska, Petr; Vasinek, Vladimir

    2016-10-01

    The technology of Fiber Bragg grating (FBG) belongs to the most widespread fiber-optic sensors. They are used for measuring a large number of physical and chemical quantities. Small size, immunity to electromagnetic interference, high sensitivity and a principle of information encoding about the measurement value into spectral characteristics causes usability of FBG sensors in medicine for monitoring vital signs such as temperature, blood pressure, pulse, and respiration. An important factor is the use of an inert material for the encapsulation of Bragg gratings in this area. A suitable choice is a polydimethylsiloxane (PDMS) elastomer having excellent thermal and elastic properties. Experimental results describe the creation of FBG sensory prototype for monitoring breathing in this paper. The sensor is realized by encapsulation of Bragg grating into PDMS. The FBG sensor is mounted on the elastic contact strap which encircles the chest of the patient. This tension leads to a spectral shift of the reflected light from the FBG. For measurement, we used a broadband light source Light-Emitting Diode (LED) with central wavelength 1550 nm and optical spectrum analyzer.

  3. Underwater breathing: the mechanics of plastron respiration

    Science.gov (United States)

    Flynn, M. R.; Bush, John W. M.

    The rough, hairy surfaces of many insects and spiders serve to render them water-repellent; consequently, when submerged, many are able to survive by virtue of a thin air layer trapped along their exteriors. The diffusion of dissolved oxygen from the ambient water may allow this layer to function as a respiratory bubble or , and so enable certain species to remain underwater indefinitely. Maintenance of the plastron requires that the curvature pressure balance the pressure difference between the plastron and ambient. Moreover, viable plastrons must be of sufficient area to accommodate the interfacial exchange of O2 and CO2 necessary to meet metabolic demands. By coupling the bubble mechanics, surface and gas-phase chemistry, we enumerate criteria for plastron viability and thereby deduce the range of environmental conditions and dive depths over which plastron breathers can survive. The influence of an external flow on plastron breathing is also examined. Dynamic pressure may become significant for respiration in fast-flowing, shallow and well-aerated streams. Moreover, flow effects are generally significant because they sharpen chemical gradients and so enhance mass transfer across the plastron interface. Modelling this process provides a rationale for the ventilation movements documented in the biology literature, whereby arthropods enhance plastron respiration by flapping their limbs or antennae. Biomimetic implications of our results are discussed.

  4. Can audio coached 4D CT emulate free breathing during the treatment course?

    DEFF Research Database (Denmark)

    Persson, Gitte F; Nygaard, Ditte E; Olsen, Mikael;

    2008-01-01

    breathing without changing the breathing amplitude. The interfraction variation of the breathing cycle amplitude in free and coached breathing was studied as well as the possible impact of fatigue on longer coaching sessions. METHODS: Thirteen volunteers completed respiratory audio coaching on 3 days within...... during an uncoached versus coached planning 4DCT, respectively, and compared the mean breathing cycle amplitude to the free versus coached breathing from day 2 and 3 simulating free versus coached breathing during treatment. RESULTS: For most volunteers it was impossible to apply coaching without changes...

  5. Electronic Nose Functionality for Breath Gas Analysis during Parabolic Flight

    Science.gov (United States)

    Dolch, Michael E.; Hummel, Thomas; Fetter, Viktor; Helwig, Andreas; Lenic, Joachim; Moukhamedieva, Lana; Tsarkow, Dimitrij; Chouker, Alexander; Schelling, Gustav

    2017-02-01

    The presence of humans in space represents a constant threat for their health and safety. Environmental factors such as living in a closed confinement, as well as exposure to microgravity and radiation, are associated with significant changes in bone metabolism, muscular atrophy, and altered immune response, which has impacts on human performance and possibly results in severe illness. Thus, maintaining and monitoring of crew health status has the highest priority to ensure whole mission success. With manned deep space missions to moon or mars appearing at the horizon where short-term repatriation back to earth is impossible the availability of appropriate diagnostic platforms for crew health status is urgently needed. In response to this need, the present experiment evaluated the functionality and practicability of a metal oxide based sensor system (eNose) together with a newly developed breath gas collecting device under the condition of altering acceleration. Parabolic flights were performed with an Airbus A300 ZeroG at Bordeaux, France. Ambient air and exhaled breath of five healthy volunteers was analyzed during steady state flight and parabolic flight maneuvres. All volunteers completed the study, the breath gas collecting device valves worked appropriately, and breathing through the collecting device was easy and did not induce discomfort. During breath gas measurements, significant changes in metal oxide sensors, mainly sensitive to aromatic and sulphur containing compounds, were observed with alternating conditions of acceleration. Similarly, metal oxide sensors showed significant changes in all sensors during ambient air measurements. The eNose as well as the newly developed breath gas collecting device, showed appropriate functionality and practicability during alternating conditions of acceleration which is a prerequisite for the intended use of the eNose aboard the International Space Station (ISS) for breath gas analysis and crew health status

  6. Qualidade de vida em sujeitos respiradores orais e oronasais Life quality for mouth and oronasal breathing subjects

    Directory of Open Access Journals (Sweden)

    Mirian Hideko Nagae

    2013-02-01

    Full Text Available OBJETIVO: investigar a qualidade de vida de sujeitos com respiração oral ou oronasal. MÉTODO: compuseram a amostra 49 voluntários, distribuídos em dois grupos: grupo de respiradores orais com 24 sujeitos e grupo de respiradores oronasais com 25 sujeitos, com faixa etária ente 18 e 38 anos de idade, de ambos os sexos. O protocolo utilizado foi o WHOQOL-BREF (versão em português e o registro e análise dos dados foi realizado pelo sistema Statistical Analysis System. RESULTADOS: os resultados obtidos foram submetidos aos testes de qui-quadrado de Mantel-Haenszele análise de variância. A qualidade de vida dos respiradores mistos se revelou inferior nos domínios ambiental, físico e psicológico em relação aos respiradores orais. CONCLUSÃO: com a detecção das diferenças obtidas, o estudo chama a atenção para a necessidade de aprofundar investigações sobre o perfil dos respiradores oronasais e sua relevância. Para que condutas como desconsiderar o grupo de respiradores oronasais ou agrupá-los como respiradores orais não sejam adotadas de forma inadequada.PURPOSE: to investigate the life quality of subjects with mouth or oronasal breathing. METHOD: the sampling was composed of 49 volunteers distributed into 2 groups: mouth breathing subjects’ group with 24 subjects and oronasal breathing subjects’ group (mouth and nose with 25 subjects, within the 18-38 age group, both genders. The WHOQOL-BREF (Portuguese version protocol was used and the data analysis and recording were carried out using the Statistical Analysis System. RESULTS: the obtained results underwent Mantel-Haenszel chi-square test and variance analysis. Life quality in oronasal breathing subjects was demonstrated to be better in environmental, physical and psychological domain in relation to mouth breathing subjects. CONCLUSION: considering the obtained differences, the study draws attention to the need for better investigating the profile of oronasal breathing

  7. Remote monitoring of breathing dynamics using infrared thermography

    Science.gov (United States)

    Pereira, Carina Barbosa; Yu, Xinchi; Czaplik, Michael; Rossaint, Rolf; Blazek, Vladimir; Leonhardt, Steffen

    2015-01-01

    An atypical or irregular respiratory frequency is considered to be one of the earliest markers of physiological distress. In addition, monitoring of this vital parameter plays a major role in diagnosis of respiratory disorders, as well as in early detection of sudden infant death syndrome. Nevertheless, the current measurement modalities require attachment of sensors to the patient’s body, leading to discomfort and stress. The current paper presents a new robust algorithm to remotely monitor breathing rate (BR) by using thermal imaging. This approach permits to detect and to track the region of interest (nose) as well as to estimate BR. In order to study the performance of the algorithm, and its robustness against motion and breathing disorders, three different thermal recordings of 11 healthy volunteers were acquired (sequence 1: normal breathing; sequence 2: normal breathing plus arbitrary head movements; and sequence 3: sequence of specific breathing patterns). Thoracic effort (piezoplethysmography) served as “gold standard” for validation of our results. An excellent agreement between estimated BR and ground truth was achieved. Whereas the mean correlation for sequence 1–3 were 0.968, 0.940 and 0.974, the mean absolute BR errors reached 0.33, 0.55 and 0.96 bpm (breaths per minute), respectively. In brief, this work demonstrates that infrared thermography is a promising, clinically relevant alternative for the currently available measuring modalities due to its performance and diverse remarkable advantages. PMID:26601003

  8. Diaphragmatic Breathing Reduces Exercise-Induced Oxidative Stress

    Directory of Open Access Journals (Sweden)

    Daniele Martarelli

    2011-01-01

    Full Text Available Diaphragmatic breathing is relaxing and therapeutic, reduces stress, and is a fundamental procedure of Pranayama Yoga, Zen, transcendental meditation and other meditation practices. Analysis of oxidative stress levels in people who meditate indicated that meditation correlates with lower oxidative stress levels, lower cortisol levels and higher melatonin levels. It is known that cortisol inhibits enzymes responsible for the antioxidant activity of cells and that melatonin is a strong antioxidant; therefore, in this study, we investigated the effects of diaphragmatic breathing on exercise-induced oxidative stress and the putative role of cortisol and melatonin hormones in this stress pathway. We monitored 16 athletes during an exhaustive training session. After the exercise, athletes were divided in two equivalent groups of eight subjects. Subjects of the studied group spent 1 h relaxing performing diaphragmatic breathing and concentrating on their breath in a quiet place. The other eight subjects, representing the control group, spent the same time sitting in an equivalent quite place. Results demonstrate that relaxation induced by diaphragmatic breathing increases the antioxidant defense status in athletes after exhaustive exercise. These effects correlate with the concomitant decrease in cortisol and the increase in melatonin. The consequence is a lower level of oxidative stress, which suggests that an appropriate diaphragmatic breathing could protect athletes from long-term adverse effects of free radicals.

  9. Advantage of using deep inspiration breath hold with active breathing control and image-guided radiation therapy for patients treated with lung cancers

    Directory of Open Access Journals (Sweden)

    KR Muralidhar

    2015-01-01

    Full Text Available Purpose: The aim of this study was to evaluate the irradiated volume and doses to the target, heart, left lung, right lung and spinal cord, the number of segments and treatment time by using moderated deep inspiration breath hold (mDIBH with active breathing control (ABC and image-guided radiotherapy (IGRT for patients treated with lung cancers.Methods: The suitability of this technique for lung patient treated with ABC was investigated and the solutions to achieve better treatments were discussed. Eleven lung cancer patients (3 left-sided and 8 right sided lesions with stages I-III underwent standard free breath (FB and ABC computed tomography (CT scans in the treatment supine position. This can be achieved by applying respiratory manoeuvres, such as mDIBH, during which the threshold volume utilized is defined as 75-80% of the maximum aspiratory capacity. Five to seven, 6-MV photon beams with optimized gantry angles were designed according to the tumor location to conform to the PTV while sparing as much heart, spinal cord, and contra lateral lung as possible. For eleven patients, treatment planning using mDIBH CT data with intensity modulated radiation therapy (IMRT was then reoptimized on the free breathing data set for comparison. The studied parameters of the plans for each patient were evaluated based on the average of the minimum, mean, and maximum difference in dose, the range of difference, and the p-value using two-tailed paired t test assuming equal variance.Results: The average volume of the planning target volume (PTV in 11 patients increased to 1.32% in ABC compared to FB. The average volume of heart in 11 patients decreased to 2.9% in ABC compared to free breathing IMRT. In the case of lungs, the volume increased to 27.5% and 25.85% for left and right lungs, respectively. The range of mean difference in dose to the PTV in 11 patients was -54 cGy to 230 cGy with ABC technique when compared with free breathing. The range of mean

  10. Variability of exhaled breath condensate (EBC) volume and pH using a feedback regulated breathing pattern

    Science.gov (United States)

    Exhaled breath condensate (EBC) is a valuable biological medium for non-invasively measuring biomarkers with the potential to reflect organ systems responses to environmental and dietary exposures and disease processes. Collection of EBC has typically been with spontaneous breat...

  11. Profiling of volatile organic compounds in exhaled breath as a strategy to find early predictive signatures of asthma in children.

    Directory of Open Access Journals (Sweden)

    Agnieszka Smolinska

    Full Text Available Wheezing is one of the most common respiratory symptoms in preschool children under six years old. Currently, no tests are available that predict at early stage who will develop asthma and who will be a transient wheezer. Diagnostic tests of asthma are reliable in adults but the same tests are difficult to use in children, because they are invasive and require active cooperation of the patient. A non-invasive alternative is needed for children. Volatile Organic Compounds (VOCs excreted in breath could yield such non-invasive and patient-friendly diagnostic. The aim of this study was to identify VOCs in the breath of preschool children (inclusion at age 2-4 years that indicate preclinical asthma. For that purpose we analyzed the total array of exhaled VOCs with Gas Chromatography time of flight Mass Spectrometry of 252 children between 2 and 6 years of age. Breath samples were collected at multiple time points of each child. Each breath-o-gram contained between 300 and 500 VOCs; in total 3256 different compounds were identified across all samples. Using two multivariate methods, Random Forests and dissimilarity Partial Least Squares Discriminant Analysis, we were able to select a set of 17 VOCs which discriminated preschool asthmatic children from transient wheezing children. The correct prediction rate was equal to 80% in an independent test set. These VOCs are related to oxidative stress caused by inflammation in the lungs and consequently lipid peroxidation. In conclusion, we showed that VOCs in the exhaled breath predict the subsequent development of asthma which might guide early treatment.

  12. Controlled-frequency breath swimming improves swimming performance and running economy.

    Science.gov (United States)

    Lavin, K M; Guenette, J A; Smoliga, J M; Zavorsky, G S

    2015-02-01

    Respiratory muscle fatigue can negatively impact athletic performance, but swimming has beneficial effects on the respiratory system and may reduce susceptibility to fatigue. Limiting breath frequency during swimming further stresses the respiratory system through hypercapnia and mechanical loading and may lead to appreciable improvements in respiratory muscle strength. This study assessed the effects of controlled-frequency breath (CFB) swimming on pulmonary function. Eighteen subjects (10 men), average (standard deviation) age 25 (6) years, body mass index 24.4 (3.7) kg/m(2), underwent baseline testing to assess pulmonary function, running economy, aerobic capacity, and swimming performance. Subjects were then randomized to either CFB or stroke-matched (SM) condition. Subjects completed 12 training sessions, in which CFB subjects took two breaths per length and SM subjects took seven. Post-training, maximum expiratory pressure improved by 11% (15) for all 18 subjects (P inspiratory pressure was unchanged. Running economy improved by 6 (9)% in CFB following training (P swimmers.

  13. Habituation to experimentally induced electrical pain during voluntary-breathing controlled electrical stimulation (BreEStim.

    Directory of Open Access Journals (Sweden)

    Shengai Li

    Full Text Available OBJECTIVE: Painful peripheral electrical stimulation to acupuncture points was found to cause sensitization if delivered randomly (EStim, but induced habituation if triggered by voluntary breathing (BreEStim. The objective was to systematically compare the effectiveness of BreEStim and EStim and to investigate the possible mechanisms mediating the habituation effect of BreEStim. METHODS: Eleven pain-free, healthy subjects (6 males, 5 females participated in the study. Each subject received the BreEStim and EStim treatments in a random order at least three days apart. Both treatments consisted of 120 painful but tolerable stimuli to the ulnar nerve at the elbow on the dominant arm. BreEStim was triggered by voluntary breathing while EStim was delivered randomly. Electrical sensation threshold (EST and electrical pain threshold (EPT were measured from the thenar and hypothenar eminences on both hands at pre-intervention and 10-minutes post-intervention. RESULTS: There was no difference in the pre-intervention baseline measurement of EST and EPT between BreEStim and EStim. BreEStim increased EPT in all tested sites on both hands, while EStim increased EPT in the dominant hypothenar eminence distal to the stimulating site and had no effect on EPT in other sites. There was no difference in the intensity of electrical stimulation between EStim and BreEStim. CONCLUSION: Our findings support the important role human voluntary breathing plays in the systemic habituation effect of BreEStim to peripheral painful electrical stimulation.

  14. Electromagnetic inductance plethysmography is well suited to measure tidal breathing in infants

    Science.gov (United States)

    Eriksen, Morten; Olsen, Merete S.; Markestad, Trond; Halvorsen, Thomas

    2016-01-01

    Reliable, accurate and noninvasive methods for measuring lung function in infants are desirable. Electromagnetic inductance plethysmography has been used to perform infant spirometry and VoluSense Pediatrics (VSP) (VoluSense, Bergen, Norway) represents an updated version of this technique. We aimed to examine its accuracy compared to a validated system measuring airflow via a facemask using an ultrasonic flowmeter. We tested 30 infants with postmenstrual ages between 36 to 43 weeks and weights from 2.3 to 4.8 kg, applying both methods simultaneously and applying VSP alone. Agreement between the methods was calculated using Bland–Altman analyses and we also estimated the effect of applying the mask. Mean differences for all breathing parameters were within ±5.5% and limits of agreement between the two methods were acceptable, except perhaps for peak tidal expiratory flow (PTEF). Application of the facemask significantly increased tidal volume, minute ventilation, PTEF, the ratio of inspiratory to expiratory time and the ratio of expiratory flow at 50% of expired volume to PTEF. VSP accurately measured tidal breathing parameters and seems well suited for tidal breathing measurements in infants under treatment with equipment that precludes the use of a facemask. PMID:28053968

  15. Fourier-based linear systems description of free-breathing pulmonary magnetic resonance imaging

    Science.gov (United States)

    Capaldi, D. P. I.; Svenningsen, S.; Cunningham, I. A.; Parraga, G.

    2015-03-01

    Fourier-decomposition of free-breathing pulmonary magnetic resonance imaging (FDMRI) was recently piloted as a way to provide rapid quantitative pulmonary maps of ventilation and perfusion without the use of exogenous contrast agents. This method exploits fast pulmonary MRI acquisition of free-breathing proton (1H) pulmonary images and non-rigid registration to compensate for changes in position and shape of the thorax associated with breathing. In this way, ventilation imaging using conventional MRI systems can be undertaken but there has been no systematic evaluation of fundamental image quality measurements based on linear systems theory. We investigated the performance of free-breathing pulmonary ventilation imaging using a Fourier-based linear system description of each operation required to generate FDMRI ventilation maps. Twelve subjects with chronic obstructive pulmonary disease (COPD) or bronchiectasis underwent pulmonary function tests and MRI. Non-rigid registration was used to co-register the temporal series of pulmonary images. Pulmonary voxel intensities were aligned along a time axis and discrete Fourier transforms were performed on the periodic signal intensity pattern to generate frequency spectra. We determined the signal-to-noise ratio (SNR) of the FDMRI ventilation maps using a conventional approach (SNRC) and using the Fourier-based description (SNRF). Mean SNR was 4.7 ± 1.3 for subjects with bronchiectasis and 3.4 ± 1.8, for COPD subjects (p>.05). SNRF was significantly different than SNRC (p<.01). SNRF was approximately 50% of SNRC suggesting that the linear system model well-estimates the current approach.

  16. Sleep-disordered breathing and mortality: a prospective cohort study.

    Directory of Open Access Journals (Sweden)

    Naresh M Punjabi

    2009-08-01

    Full Text Available BACKGROUND: Sleep-disordered breathing is a common condition associated with adverse health outcomes including hypertension and cardiovascular disease. The overall objective of this study was to determine whether sleep-disordered breathing and its sequelae of intermittent hypoxemia and recurrent arousals are associated with mortality in a community sample of adults aged 40 years or older. METHODS AND FINDINGS: We prospectively examined whether sleep-disordered breathing was associated with an increased risk of death from any cause in 6,441 men and women participating in the Sleep Heart Health Study. Sleep-disordered breathing was assessed with the apnea-hypopnea index (AHI based on an in-home polysomnogram. Survival analysis and proportional hazards regression models were used to calculate hazard ratios for mortality after adjusting for age, sex, race, smoking status, body mass index, and prevalent medical conditions. The average follow-up period for the cohort was 8.2 y during which 1,047 participants (587 men and 460 women died. Compared to those without sleep-disordered breathing (AHI: or=30.0 events/h sleep-disordered breathing were 0.93 (95% CI: 0.80-1.08, 1.17 (95% CI: 0.97-1.42, and 1.46 (95% CI: 1.14-1.86, respectively. Stratified analyses by sex and age showed that the increased risk of death associated with severe sleep-disordered breathing was statistically significant in men aged 40-70 y (hazard ratio: 2.09; 95% CI: 1.31-3.33. Measures of sleep-related intermittent hypoxemia, but not sleep fragmentation, were independently associated with all-cause mortality. Coronary artery disease-related mortality associated with sleep-disordered breathing showed a pattern of association similar to all-cause mortality. CONCLUSIONS: Sleep-disordered breathing is associated with all-cause mortality and specifically that due to coronary artery disease, particularly in men aged 40-70 y with severe sleep-disordered breathing. Please see later in the

  17. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  18. Radial Breathing Modes in Cosmochemistry and Meteoritics

    Science.gov (United States)

    Wilson, T.L.; Wilson, K.B.

    2009-01-01

    One area of continuing interest in cosmochemistry and meteoritics (C&M) is the identification of the nature of Q-phase, although some researchers in C&M are not reporting relevant portions of Raman spectral data. Q is the unidentified carrier of noble gases in carbonaceous chondrites (CCs). Being carbonaceous, the focus has been on any number of Q-candidates arising from the sp2 hybridization of carbon (C). These all derive from various forms of graphene, a monolayer of C atoms packed into a two-dimensional (2D) hexagonal honeycomb lattice that is the basic building block for graphitic materials of all other dimensions for sp2 allotropes of C. As a basic lattice, 2D graphene can be curled into fullerenes (0D), wrapped into carbon nanotubes or CNTs (1D), and stacked into graphite (3D). These take such additional forms as scroll-like carbon whiskers, carbon fibers, carbon onions, GPCs (graphite polyhedral crystals) [6], and GICs (graphite intercalation compounds). Although all of these have been observed in meteoritics, the issue is which can explain the Q-abundances. In brief, one or more of the 0D-3D sp2 hybridization forms of C is Q. For some Q-candidates, the radial breathing modes (RBMs) are the most important Raman active vibrational modes that exist, and bear a direct relevance to solving this puzzle. Typically in C&M they are ignored when present. Their importance is addressed here as smoking-gun signatures for certain Q-candidates and are very relevant to the ultimate identification of Q.

  19. Experimental setup and analytical methods for the non-invasive determination of volatile organic compounds, formaldehyde and NO{sub x} in exhaled human breath

    Energy Technology Data Exchange (ETDEWEB)

    Riess, Ulrich; Tegtbur, Uwe [Hannover Medical School, Sports Physiology and Sports Medicine, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Fauck, Christian; Fuhrmann, Frank; Markewitz, Doreen [Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig (Germany); Salthammer, Tunga, E-mail: tunga.salthammer@wki.fraunhofer.de [Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig (Germany)

    2010-06-11

    Different analytical devices were tested and evaluated for their suitability of breath gas analysis by examining the physiological parameters and chemical substances in the exhaled breath of ten healthy probands during light cycling in dependence of methanol-rich nutrition. The probands exercised under normal breathing conditions on a bicycle ergometer. Breath air was exhaled into a glass cylinder and collected under steady-state conditions. Non-invasively measured parameters were pulse rate, breath frequency, temperature, relative humidity, NO{sub x}, total volatile organic compounds (TVOC{sub PAS}), carbon dioxide (CO{sub 2}), formaldehyde, methanol, acetaldehyde, acetone, isoprene and volatile organic compounds (VOCs). Methanol rich food and beverages strongly influenced the concentration of methanol and other organic substances in human breath. On the other hand, nutrition and smoking had no clear effect on the physical conditions of the probands. The proton transfer reaction mass spectrometry (PTR-MS) method was found to be very suitable for the analysis of breath gas but the m/z 31, if assigned to formaldehyde, is sensitive to interferences. The time vs. concentration curves of nitric oxide showed sudden peaks up to 120 ppb in most of the measurements. In one case a strong interference of the NO{sub x} signal was observed. The time resolved analysis of exhaled breath gas is of high capability and significance for different applications if reliable analytical techniques are used. Some compounds like nitric oxide (NO), methanol, different VOCs as well as sum parameters like TVOC{sub PAS} are especially suitable as markers. Formaldehyde, which is rapidly metabolized in the human body, could be measured reliably as a trace component by the acetylacetone (acac) method but not by PTR-MS.

  20. Fast-starting after a breath: air-breathing motions are kinematically similar to escape responses in the catfish Hoplosternum littorale

    DEFF Research Database (Denmark)

    Domenici, Paolo; Norin, Tommy; Bushnell, Peter G.;

    2015-01-01

    that air-breathing fish may use C-starts in the context of gulping air at the surface. Hoplosternum littorale is an air-breathing freshwater catfish found in South America. Field video observations reveal that their air-breathing behaviour consists of air-gulping at the surface, followed by a fast turn...

  1. Increased Prevalence of Sleep-Disordered Breathing in Adults

    Science.gov (United States)

    Peppard, Paul E.; Young, Terry; Barnet, Jodi H.; Palta, Mari; Hagen, Erika W.; Hla, Khin Mae

    2013-01-01

    Sleep-disordered breathing is a common disorder with a range of harmful sequelae. Obesity is a strong causal factor for sleep-disordered breathing, and because of the ongoing obesity epidemic, previous estimates of sleep-disordered breathing prevalence require updating. We estimated the prevalence of sleep-disordered breathing in the United States for the periods of 1988–1994 and 2007–2010 using data from the Wisconsin Sleep Cohort Study, an ongoing community-based study that was established in 1988 with participants randomly selected from an employed population of Wisconsin adults. A total of 1,520 participants who were 30–70 years of age had baseline polysomnography studies to assess the presence of sleep-disordered breathing. Participants were invited for repeat studies at 4-year intervals. The prevalence of sleep-disordered breathing was modeled as a function of age, sex, and body mass index, and estimates were extrapolated to US body mass index distributions estimated using data from the National Health and Nutrition Examination Survey. The current prevalence estimates of moderate to severe sleep-disordered breathing (apnea-hypopnea index, measured as events/hour, ≥15) are 10% (95% confidence interval (CI): 7, 12) among 30–49-year-old men; 17% (95% CI: 15, 21) among 50–70-year-old men; 3% (95% CI: 2, 4) among 30–49-year-old women; and 9% (95% CI: 7, 11) among 50–70 year-old women. These estimated prevalence rates represent substantial increases over the last 2 decades (relative increases of between 14% and 55% depending on the subgroup). PMID:23589584

  2. [Periodic breathing with periodic oxygen variation in infancy].

    Science.gov (United States)

    von Czettritz, G; Bax, R T; Eckardt, T; Springer, S; Emmrich, P

    1996-01-01

    Oxycardiorespirographies, recording arterial oxygen saturation (SaO2), breathing movements, heart rate and ECG with a mean recording time of 22.3 hours, were performed on 85 preterm (mean postconceptional age: 38 weeks) and 81 term infants (mean postconceptional age 42.4 weeks). 83% of the preterm infants showed periodic breathing (PB), in 97% of them this was accompanied by periodic variations of arterial oxygen saturation (PVO). Periodic breathing occurred in 61% of the term infants, 84% of them showed PVO during periodic breathing. The mean variation of oxygen saturation was between 92.8 and 96.8% (+/- 1.7) for preterm and between 92.9 and 96.0% (+/- 2.2) for term infants. In some infants the peak to peak amplitude of the SaO2 cycles was up to 22%, sometimes a further fall of SaO2 occurred. There was a strong correlation of the PVO both at the beginning and end of the episode as well as with the PB-cycle periodicity itself. The fall of the oxygen saturation occurred 3.1 to 7.8 s after the beginning of the first apnea of an episode of periodic breathing, the minimum SaO2 was reached approximately 4.2 to 8.6 s later. This periodic rapid fall of SaO2 from a high oxygenation level cannot be explained by the apneas of a rather short duration during periodic breathing. It is discussed that PVO during periodic breathing may be caused by an ideopathic right to left shunting across fetal circulation pathways which occurs intermittently and periodically. This mechanism could-via patterns of reaction exhibited during the fetal and neonatal time period-lead to acute hypoxemia, as found in apparently life threatening events (ALTE) and as postulated in sudden infant death (SID).

  3. Noninvasive detection of lung cancer by analysis of exhaled breath

    Directory of Open Access Journals (Sweden)

    Denz Hubert

    2009-09-01

    Full Text Available Abstract Background Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of lung cancer very often happens late in the course of the disease since inexpensive, non-invasive and sufficiently sensitive and specific screening methods are not available. Even though the CT diagnostic methods are good, it must be assured that "screening benefit outweighs risk, across all individuals screened, not only those with lung cancer". An early non-invasive diagnosis of lung cancer would improve prognosis and enlarge treatment options. Analysis of exhaled breath would be an ideal diagnostic method, since it is non-invasive and totally painless. Methods Exhaled breath and inhaled room air samples were analyzed using proton transfer reaction mass spectrometry (PTR-MS and solid phase microextraction with subsequent gas chromatography mass spectrometry (SPME-GCMS. For the PTR-MS measurements, 220 lung cancer patients and 441 healthy volunteers were recruited. For the GCMS measurements, we collected samples from 65 lung cancer patients and 31 healthy volunteers. Lung cancer patients were in different disease stages and under treatment with different regimes. Mixed expiratory and indoor air samples were collected in Tedlar bags, and either analyzed directly by PTR-MS or transferred to glass vials and analyzed by gas chromatography mass spectrometry (GCMS. Only those measurements of compounds were considered, which showed at least a 15% higher concentration in exhaled breath than in indoor air. Compounds related to smoking behavior such as acetonitrile and benzene were not used to differentiate between lung cancer patients and healthy volunteers. Results Isoprene, acetone and methanol are compounds appearing in everybody's exhaled breath. These three main compounds of exhaled breath show slightly lower concentrations in lung cancer patients as compared to healthy volunteers (p Conclusion GCMS-SPME is a relatively

  4. Association between oral habits, mouth breathing and malocclusion.

    Science.gov (United States)

    Grippaudo, C; Paolantonio, E G; Antonini, G; Saulle, R; La Torre, G; Deli, R

    2016-10-01

    The ratio of bad habits, mouth breathing and malocclusion is an important issue in view of prevention and early treatment of disorders of the craniofacial growth. While bad habits can interfere with the position of the teeth and normal pattern of skeletal growth, on the other hand obstruction of the upper airway, resulting in mouth breathing, changes the pattern of craniofacial growth causing malocclusion. Our crosssectional study, carried out on 3017 children using the ROMA index, was developed to verify if there was a significant correlation between bad habits/mouth breathing and malocclusion. The results showed that an increase in the degree of the index increases the prevalence of bad habits and mouth breathing, meaning that these factors are associated with more severe malocclusions. Moreover, we found a significant association of bad habits with increased overjet and openbite, while no association was found with crossbite. Additionally, we found that mouth breathing is closely related to increased overjet, reduced overjet, anterior or posterior crossbite, openbite and displacement of contact points. Therefore, it is necessary to intervene early on these aetiological factors of malocclusion to prevent its development or worsening and, if already developed, correct it by early orthodontic treatment to promote eugnatic skeletal growth.

  5. Acoustic rhinometry in mouth breathing patients: a systematic review

    Directory of Open Access Journals (Sweden)

    Ana Carolina Cardoso de Melo

    2015-04-01

    Full Text Available INTRODUCTION: When there is a change in the physiological pattern of nasal breathing, mouth breathing may already be present. The diagnosis of mouth breathing is related to nasal patency. One way to access nasal patency is by acoustic rhinometry.OBJECTIVE: To systematically review the effectiveness of acoustic rhinometry for the diagnosis of patients with mouth breathing.METHODS: Electronic databases LILACS, MEDLINE via PubMed and Bireme, SciELO, Web of Science, Scopus, PsycInfo, CINAHL, and Science Direct, from August to December 2013, were consulted. 11,439 articles were found: 30 from LILACS, 54 from MEDLINE via Bireme, 5558 from MEDLINE via PubMed, 11 from SciELO, 2056 from Web of Science, 1734 from Scopus, 13 from PsycInfo, 1108 from CINAHL, and 875 from Science Direct. Of these, two articles were selected.RESULTS: The heterogeneity in the use of equipment and materials for the assessment of respiratory mode in these studies reveals that there is not yet consensus in the assessment and diagnosis of patients with mouth breathing.CONCLUSION: According to the articles, acoustic rhinometry has been used for almost twenty years, but controlled studies attesting to the efficacy of measuring the geometry of nasal cavities for complementary diagnosis of respiratory mode are warranted.

  6. [The influence of breathing mode on the oral cavity].

    Science.gov (United States)

    Surtel, Anna; Klepacz, Robert; Wysokińska-Miszczuk, Joanna

    2015-12-01

    Nose breathing is one of the key factors in the proper development and functioning of the oral cavity. The air passing through the nasal cavity is warmed and humidified while dust and other particulate matter is removed. It is also important as far as bone formation is concerned. The obstruction or congestions of the upper respiratory tract may negatively affect the correct and most optimal (nasal) respiratory tract. The switch from nasal to mouth breathing may lead to serious clinical consequences. Children with the clinical diagnosis of mouth breathing are usually pale, apathetic and they lack concentration and often get tired. Disorders resulting from hypoxy may also be the reason from sleep disturbances, such as frequent waking-up, nocturia, difficulties falling aslee. The main clinical manifestations of mouth breathing appear in the craniofacial structures. Mouth breathers frequently suffer from dental malocclusions and craniofacial bone abnormalities. Chronic muscle tension around the oral cavity could result in the widening of cranio-vertebral angle, posterior position of mandibula and narrow maxillary arch. Among dental alterations the most common are class II malocclusion (total or partial) with the protrusion of the anterior teeth, cross bite (unilateral or bilateral), anterior open bite and primary crowded teeth. Apart from malocclusion, chronic gingivitis, periodontitis, candida infections and halitosis are frequently present in mouth--breathing patients.

  7. Modular Sampling and Analysis Techniques for the Real-Time Analysis of Human Breath

    Energy Technology Data Exchange (ETDEWEB)

    Frank, M; Farquar, G; Adams, K; Bogan, M; Martin, A; Benner, H; Spadaccini, C; Steele, P; Davis, C; Loyola, B; Morgan, J; Sankaran, S

    2007-07-09

    At LLNL and UC Davis, we are developing several techniques for the real-time sampling and analysis of trace gases, aerosols and exhaled breath that could be useful for a modular, integrated system for breath analysis. Those techniques include single-particle bioaerosol mass spectrometry (BAMS) for the analysis of exhaled aerosol particles or droplets as well as breath samplers integrated with gas chromatography mass spectrometry (GC-MS) or MEMS-based differential mobility spectrometry (DMS). We describe these techniques and present recent data obtained from human breath or breath condensate, in particular, addressing the question of how environmental exposure influences the composition of breath.

  8. Quantum spin liquid in a breathing kagome lattice

    Science.gov (United States)

    Schaffer, Robert; Huh, Yejin; Hwang, Kyusung; Kim, Yong Baek

    2017-02-01

    Motivated by recent experiments on the vanadium oxyfluoride material DQVOF, we examine possible spin liquid phases on a breathing kagome lattice of S =1 /2 spins. By performing a projective symmetry group analysis, we determine the possible phases for both fermionic and bosonic Z2 spin liquids on this lattice, and establish the correspondence between the two. The nature of the ground state of the Heisenberg model on the isotropic kagome lattice is a hotly debated topic, with both Z2 and U(1) spin liquids argued to be plausible ground states. Using variational Monte Carlo techniques, we show that a gapped Z2 spin liquid emerges as the clear ground state in the presence of this breathing anisotropy. Our results suggest that the breathing anisotropy helps to stabilize this spin liquid ground state, which may aid us in understanding the results of experiments and help to direct future numerical studies on these systems.

  9. Liquid intake monitoring through breathing signal using machine learning

    Science.gov (United States)

    Dong, Bo; Biswas, Subir

    2013-05-01

    This paper presents the design, system structure and performance for a wireless and wearable diet monitoring system. Food and drink intake can be detected by the way of detecting a person's swallow events. The system works based on the key observation that a person's otherwise continuous breathing process is interrupted by a short apnea when she or he swallows as a part of solid or liquid intake process. We detect the swallows through the difference between normal breathing cycle and breathing cycle with swallows using a wearable chest-belt. Three popular machine learning algorithms have been applied on both time and frequency domain features. Discrimination power of features is then analyzed for applications where only small number of features is allowed. It is shown that high detection performance can be achieved with only few features.

  10. Wash-out of ambient air contaminations for breath measurements.

    Science.gov (United States)

    Maurer, F; Wolf, A; Fink, T; Rittershofer, B; Heim, N; Volk, T; Baumbach, J I; Kreuer, S

    2014-06-01

    In breath analysis, ambient air contaminations are ubiquitous and difficult to eliminate. This study was designed to investigate the reduction of ambient air background by a lung wash-out with synthetic air. The reduction of the initial ambient air volatile organic compound (VOC) intensity was investigated in the breath of 20 volunteers inhaling synthetic air via a sealed full face mask in comparison to inhaling ambient air. Over a period of 30 minutes, breath analysis was conducted using ion mobility spectrometry coupled to a multi-capillary column. A total of 68 VOCs were identified for inhaling ambient air or inhaling synthetic air. By treatment with synthetic air, 39 VOCs decreased in intensity, whereas 29 increased in comparison to inhaling ambient air. In total, seven VOCs were significantly reduced (P-value ambient air contaminations from the airways by a lung wash-out with synthetic air.

  11. Breathing detection with a portable impedance measurement system: first measurements.

    Science.gov (United States)

    Cordes, Axel; Foussier, Jerome; Leonhardt, Steffen

    2009-01-01

    For monitoring the health status of individuals, detection of breathing and heart activity is important. From an electrical point of view, it is known that breathing and heart activity change the electrical impedance distribution in the human body over the time due to ventilation (high impedance) and blood shifts (low impedance). Thus, it is possible to detect both important vital parameters by measuring the impedance of the thorax or the region around lung and heart. For some measurement scenarios it is also essential to detect these parameters contactless. For instance, monitoring bus drivers health could help to limit accidents, but directly connected systems limit the drivers free moving space. One measurement technology for measuring the impedance changes in the chest without cables is the magnetic impedance tomography (MIT). This article describes a portable measurement system we developed for this scenario that allows to measure breathing contactless. Furthermore, first measurements with five volunteers were performed and analyzed.

  12. Theme and variations: amphibious air-breathing intertidal fishes.

    Science.gov (United States)

    Martin, K L

    2014-03-01

    Over 70 species of intertidal fishes from 12 families breathe air while emerging from water. Amphibious intertidal fishes generally have no specialized air-breathing organ but rely on vascularized mucosae and cutaneous surfaces in air to exchange both oxygen and carbon dioxide. They differ from air-breathing freshwater fishes in morphology, physiology, ecology and behaviour. Air breathing and terrestrial activity are present to varying degrees in intertidal fish species, correlated with the tidal height of their habitat. The gradient of amphibious lifestyle includes passive remainers that stay in the intertidal zone as tides ebb, active emergers that deliberately leave water in response to poor aquatic conditions and highly mobile amphibious skipper fishes that may spend more time out of water than in it. Normal terrestrial activity is usually aerobic and metabolic rates in air and water are similar. Anaerobic metabolism may be employed during forced exercise or when exposed to aquatic hypoxia. Adaptations for amphibious life include reductions in gill surface area, increased reliance on the skin for respiration and ion exchange, high affinity of haemoglobin for oxygen and adjustments to ventilation and metabolism while in air. Intertidal fishes remain close to water and do not travel far terrestrially, and are unlikely to migrate or colonize new habitats at present, although in the past this may have happened. Many fish species spawn in the intertidal zone, including some that do not breathe air, as eggs and embryos that develop in the intertidal zone benefit from tidal air emergence. With air breathing, amphibious intertidal fishes survive in a variable habitat with minimal adjustments to existing structures. Closely related species in different microhabitats provide unique opportunities for comparative studies.

  13. Detecting indoor CO exposure by measuring CO in exhaled breath

    Energy Technology Data Exchange (ETDEWEB)

    Verhoeff, A.P.; van der Velde, H.C.; Boleij, J.S.; Lebret, E.; Brunekreef, B.

    1983-01-01

    CO levels in exhaled breath were measured in 29 residents of flats, equipped with a flueless geiser (an instantaneous gas-fired water heater). The flats were selected because they had a geiser with a CO concentration of more than 250 parts per million in its flue gases. Small, but in some cases statistically significant increases in CO levels in exhaled breath were found in both smokers and non smokers, and after periods of cooking and dishwashing when the geisers had been used. Calculated COHb levels remained well below 2.5% for non smokers, but were generally higher for smokers.

  14. Breathing zone concentrations of methylmethacrylate monomer during joint replacement operations

    DEFF Research Database (Denmark)

    Darre, E; Jørgensen, L G; Vedel, P;

    1992-01-01

    By use of a methylmethacrylate (MMA) Dräger tube and bellow bump, the breathing zone concentrations of MMA monomer were measured for the operating surgeon during cementation of the components of hip and knee joint prostheses. The highest recordings (50-100 p.p.m.) were encountered during cementat......By use of a methylmethacrylate (MMA) Dräger tube and bellow bump, the breathing zone concentrations of MMA monomer were measured for the operating surgeon during cementation of the components of hip and knee joint prostheses. The highest recordings (50-100 p.p.m.) were encountered during...

  15. Airflow Characteristics at the Breathing Zone of a Seated Person

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Nagano, Hideaki; Melikov, Arsen Krikor;

    2011-01-01

    . Passive method for control over the airflow characteristics at the breathing zone to increase the amount of clean air in inhalation consisted of a rectangular board (0.63 m x 0.36 m) placed below the table and pressed against the abdominal. It acted as a barrier reducing the convection flow upcoming from...... the lower body. The resultant velocity field at the breathing zone was measured with Particle Image Velocimetry: a dual cavity laser (λ = 532 nm) and two CCD cameras with 35 and 60 mm lenses. Seeding consisting of glycerol droplets (d = 2-3 μm) was added to the total volume supply. The blocking...

  16. Padrão respiratório e movimento toracoabdominal de crianças respiradoras orais Breathing pattern and thoracoabdominal motion in mouth-breathing children

    Directory of Open Access Journals (Sweden)

    TCS Brant

    2008-12-01

    Full Text Available OBJETIVO: Caracterizar o padrão respiratório e o movimento toracoabdominal de crianças respiradoras orais, na faixa etária entre oito e dez anos, e compará-lo ao de seus pares respiradoras nasais. MÉTODOS: Estudo observacional realizado em laboratório universitário. O número amostral calculado com base em um estudo piloto com dez crianças em cada grupo, perfazendo um total de 20 crianças, foi de 50 para um nível de significância de 0,05 e um poder estatístico de 0,80. Participaram do estudo 26 crianças respiradoras orais e 25 respiradoras nasais. A pletismografia respiratória por indutância calibrada foi o instrumento utilizado para a análise das seguintes variáveis, entre outras: freqüência respiratória (FR, contribuição da caixa torácica para o volume corrente (%CT/Vc, ângulo de fase (Angfase e a razão entre o tempo para alcançar o pico de fluxo inspiratório e o tempo inspiratório (PifT/Ti. A saturação periférica da hemoglobia em oxigênio (SpO2 foi medida pela oximetria de pulso. A análise estatística foi realizada por meio do teste t de Student para grupos independentes e do teste U de Mann-Whitney, em função da distribuição das variáveis. RESULTADOS: No total, 4.816 ciclos respiratórios foram analisados, sendo 2.455 de respiradores orais e 2.361 de respiradores nasais, com média de 94 ciclos por criança. Não houve diferença significativa entre os grupos nas variáveis estudadas (FR=20,00±2,68 versus 20,73±2,58, p=0,169; %CT/Vc=39,30±11,86 versus 38,36±10,93, p=0,769; Angfase=14,53±7,97 versus 13,31±7,74, p=0,583; PifT/Ti=57,40±7,16 versus 58,35±5,99, p=0,610; SpO2=96,42±1,52% versus 96,88±1,01%, p=0,208; respectivamente. CONCLUSÕES: Estes resultados sugerem que as crianças respiradoras orais apresentam padrão respiratório e movimento toracoabdominal semelhantes às de respiradores nasais de mesma faixa etária.OBJECTIVE: To characterize the breathing pattern and thoracoabdominal

  17. Does breathing type influence electromyographic activity of obligatory and accessory respiratory muscles?

    Science.gov (United States)

    Gutiérrez, M F; Valenzuela, S; Miralles, R; Portus, C; Santander, H; Fuentes, A D; Celhay, I

    2014-11-01

    Craniomandibular electromyographic (EMG) studies frequently include several parameters, e.g. resting, chewing and tooth-clenching. EMG activity during these parameters has been recorded in the elevator muscles, but little is known about the respiratory muscles. The aim of this study was to compare EMG activity in obligatory and accessory respiratory muscles between subjects with different breathing types. Forty male subjects were classified according to their breathing type into two groups of 20 each: costo-diaphragmatic breathing type and upper costal breathing type. Bipolar surface electrodes were placed on the sternocleidomastoid, diaphragm, external intercostal and latissimus dorsi muscles. EMG activity was recorded during the following tasks: (i) normal quiet breathing, (ii) maximal voluntary clenching in intercuspal position, (iii) natural rate chewing until swallowing threshold, (iv) short-time chewing. Diaphragm EMG activity was significantly higher in the upper costal breathing type than in the costo-diaphragmatic breathing type in all tasks (P breathing type than in the costo-diaphragmatic breathing type in tasks 3 and 4 (P breathing types in the tasks studied (P > 0·05). The significantly higher EMG activity observed in subjects with upper costal breathing than in the costo-diaphragmatic breathing type suggests that there could be differences in motor unit recruitment strategies depending on the breathing type. This may be an expression of the adaptive capability of muscle chains in subjects who clinically have a different thoraco-abdominal expansion during inspiration at rest.

  18. Teste respiratório da 13C-metacetina na doença hepática crônica pelo vírus C 13C-methacetin breath test in hepatitis C chronic liver disease

    OpenAIRE

    Ana Cláudia de Oliveira; Marialice Reber; Valéria Lanzoni; Maria Lúcia Ferraz; Edison Roberto Parise

    2006-01-01

    RACIONAL: O teste respiratório da metacetina marcada com carbono 13 (13C-metacetina) é método não-invasivo que permite examinar a função hepática microssomal, permitindo avaliação quantitativa da massa hepática funcional. OBJETIVO: Avaliar a utilidade clinica do teste respiratório da 13C-metacetina na avaliação de pacientes com doença crônica do fígado pelo vírus da hepatite C. CASUÍSTICA E MÉTODOS: Setenta e oito pacientes com hepatite crônica C e 13 indivíduos saudáveis pareados por sexo e ...

  19. Effects of Exogenous Lactase Administration on Hydrogen Breath Excretion and Intestinal Symptoms in Patients Presenting Lactose Malabsorption and Intolerance

    Directory of Open Access Journals (Sweden)

    Ivan Ibba

    2014-01-01

    Full Text Available Objective. To establish whether supplementation with a standard oral dose of Beta-Galactosidase affects hydrogen breath excretion in patients presenting with lactose malabsorption. Methods. Ninety-six consecutive patients positive to H2 Lactose Breath Test were enrolled. Mean peak H2 levels, the time to reach the peak H2, the time to reach the cut-off value of 20 ppm, the cumulative breath H2 excretion, the areas under the curve, and a Visual Analogical 10-point Scale for symptoms were calculated. Genotyping of the C/T-13910 variant was carried out. Results. Following the oral administration of Beta-Galactosidase, in 21.88% of the cases, H2 Lactose Breath Test became negative (Group A, while mean peak H2 levels (74.95 ppm versus 7.85, P<0.0000, in 17.71% (Group B were still positive, with the H2 level 20 ppm above the baseline, but the peak H2 levels were significantly lower than those observed at the baseline test (186.7 ppm versus 66.64, P<0.0000, while in 60.41% (Group C they were still positive with the peak H2 levels similar to those observed at the baseline test (94.43 versus 81.60 ppm. All 96 individuals tested presented the C/C-13910 genotype nonpersistence. Conclusions. The response to oral administration of Beta-Galactosidase in patients with symptoms of lactose malabsorption presents a significant variability.

  20. Longitudinal study of a mouse model of chronic pulmonary inflammation using breath hold gated micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Artaechevarria, Xabier; Perez-Martin, Daniel; Munoz-Barrutia, Arrate; Ortiz-de-Solorzano, Carlos [Center for Applied Medical Research, University of Navarra, Cancer Imaging Laboratory, Oncology Division, Pamplona (Spain); Blanco, David; Biurrun, Gabriel de; Montuenga, Luis M. [Center for Applied Medical Research, University of Navarra, Biomarkers Laboratory, Pamplona (Spain); Torres, Juan P. de; Zulueta, Javier J. [Clinica Universidad de Navarra, Pneumology Department, Pamplona (Spain); Bastarrika, Gorka [Clinica Universidad de Navarra, Radiology Department, Pamplona (Spain)

    2010-11-15

    To evaluate the feasibility of using automatic quantitative analysis of breath hold gated micro-CT images to detect and monitor disease in a mouse model of chronic pulmonary inflammation, and to compare image-based measurements with pulmonary function tests and histomorphometry. Forty-nine A/J mice were used, divided into control and inflammation groups. Chronic inflammation was induced by silica aspiration. Fourteen animals were imaged at baseline, and 4, 14, and 34 weeks after silica aspiration, using micro-CT synchronized with ventilator-induced breath holds. Lung input impedance was measured as well using forced oscillation techniques. Five additional animals from each group were killed after micro-CT for comparison with histomorphometry. At all time points, micro-CT measurements show statistically significant differences between the two groups, while first differences in functional test parameters appear at 14 weeks. Micro-CT measurements correlate well with histomorphometry and discriminate diseased and healthy groups better than functional tests. Longitudinal studies using breath hold gated micro-CT are feasible on the silica-induced model of chronic pulmonary inflammation, and automatic measurements from micro-CT images correlate well with histomorphometry, being more sensitive than functional tests to detect lung damage in this model. (orig.)

  1. EFFECT OF POSITIVE EXPIRATORY PRESSURE ON BREATHING PATTERN IN HEALTHY-SUBJECTS

    NARCIS (Netherlands)

    VANDERSCHANS, CP; DEJONG, W; DEVRIES, G; POSTMA, DS; KOETER, GH; VANDERMARK, TW

    1993-01-01

    The purpose of this study was to register breathing patterns, in healthy subjects, during breathing with a positive expiratory pressure. Integrated electromyographic (IEMG) activity of the following muscles was assessed: scalene muscle, parasternal muscle and abdominal muscles, using surface electro

  2. Effect of mouth breathing on masticatory muscle activity during chewing food.

    Science.gov (United States)

    Ikenaga, N; Yamaguchi, K; Daimon, S

    2013-06-01

    The aim of this study was to examine the effect of mouth breathing on masticatory muscle activity during chewing food. Masseter muscle activity during chewing of a rice ball was recorded in 45 adult volunteers (three women), identified as nose breathers. Surface electrodes were placed on the skin according to the orientation of the masseter muscle to record the activity of this muscle while the subjects chewed the food until swallowing. Each activity was recorded twice, once with nose breathing and once with mouth breathing induced by nasal obstruction. The integrated and mean electromyography values for mouth breathing were significantly lower than the values for nose breathing (P mouth breathing compared with nose breathing (P mouth breathing decreases chewing activity and reduces the vertical effect upon the posterior teeth.

  3. Analysis of breath volatile organic compounds as a screening tool for detection of Tuberculosis in cattle

    Science.gov (United States)

    • Keywords: bovine tuberculosis; Mycobacterium bovis; breath analysis; volatile organic compound; gas chromatography; mass spectrometry; NaNose • Introduction: This presentation describes two studies exploring the use of breath VOCs to identify Mycobacterium bovis infection in cattle. • Methods: ...

  4. Breath Hydrogen Produced by Ingestion of Commercial Hydrogen Water and Milk

    OpenAIRE

    Akito Shimouchi; Kazutoshi Nose; Makoto Yamaguchi; Hiroshi Ishiguro; Takaharu Kondo

    2009-01-01

    Objective: To compare how and to what extent ingestion of hydrogen water and milk increase breath hydrogen in adults.Methods: Five subjects without specific diseases, ingested distilled or hydrogen water and milk as a reference material that could increase breath hydrogen. Their end-alveolar breath hydrogen was measured.Results: Ingestion of hydrogen water rapidly increased breath hydrogen to the maximal level of approximately 40 ppm 10–15 min after ingestion and thereafter rapidly decrease...

  5. Relationship between Musical Characteristics and Temporal Breathing Pattern in Piano Performance

    OpenAIRE

    Yutaka Sakaguchi; Eriko Aiba

    2016-01-01

    Although there is growing evidence that breathing is modulated by various motor and cognitive activities, the nature of breathing in musical performance has been little explored. The present study examined the temporal breath pattern in piano performance, aiming to elucidate how breath timing is related to musical organization/events and performance. In the experiments, the respiration of 15 professional and amateur pianists, playing 10 music excerpts in total (from four-octave C major scale,...

  6. Vertebro-basilar Ischemia and Sleep Related Breathing Disorders (Abstract)

    Institute of Scientific and Technical Information of China (English)

    You Guoxiong; Yang Hongjun; Zhu Shixiu; Zhang Kejing

    2000-01-01

    @@Introduction The relationship between cerebrovascular diseases (CVD) and sleep-related breathing disorders (SRBD) has attracted people's attention more and more in the past years. However,the subtentorial ischemic attacks - vertibrobasilar ischemia (VBI) has not been reported yet. This study is to show the interaction between VBI and SRBD.

  7. A hydrogen peroxide sensor for exhaled breath measurement

    NARCIS (Netherlands)

    Anh, Dam T.V.; Olthuis, W.; Bergveld, P.; Berg, van den A.

    2004-01-01

    An increase in produced hydrogen peroxide concentration in exhaled breath (EB) of patients, who suffer from some diseases related to lung function, has been observed and considered as a reliable indicator of lung diseases. In the EB of these patients, hydrogen peroxide is present in the vapour phase

  8. A hydrogen peroxide sensor for exhaled breath measurement

    NARCIS (Netherlands)

    Anh, Dam Thi Van; Olthuis, W.; Bergveld, P.

    2005-01-01

    An increase in hydrogen peroxide concentration in exhaled breath (EB) of patients, who suffer from some diseases related to the lung function, has been observed and considered as a reliable indicator of lung diseases. In the EB of these patients, hydrogen peroxide is present in the vapour phase toge

  9. Don't You Dare Breathe That Air!

    Science.gov (United States)

    American Lung Association, New York, NY.

    Designed for elementary school students, the workbook focuses on the unhealthy and unpleasant effects of air pollution. Space is provided for students to draw pictures of: (1) how breathing polluted air can make people feel, (2) what polluted air can do to people's health--especially if they smoke cigarettes, (3) what air pollution can do to the…

  10. Suck, swallow and breathing coordination in infants with infantile colic

    Directory of Open Access Journals (Sweden)

    Hanlie Degenaar

    2015-02-01

    Full Text Available Background: There appears to be a perception amongst parents and in popular literature that infantile colic is caused by feeding difficulties. Limited support for this perception is found in scientific literature. Whilst there is scientific evidence that suck, swallow and breathing are key components of successful feeding, these components and the coordination thereof in infants with colic have not been extensively researched.Objective: The objective of the study was to explore the suck, swallow and breathing coordination in infants with infantile colic and compare it with infants without the condition.Method: An assessment protocol for suck, swallow and breathing coordination was compiled from literature. This protocol was performed on a research group of 50 infants, independently diagnosed with infantile colic, and a control group of 28 infants without the condition. All participants were from two rural towns in the North–West province, South Africa, selected with a snowball selection method and strict selection criteria. The study followed a static comparison group design. Results: A significant difference in the key components of feeding and the presence of colic in participants of four age categories were found. The correlation between postural control and the presence of infantile colic were sustained in participants from 2–19 weeks old. Conclusion: Suck, swallow and breathing were found to be significantly associated with infantile colic. The findings should be investigated further. It appears that speech-language therapists may play an expanding role in infantile colic.[pdf to follow

  11. Take a Breath (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2015-03-26

    Breathing is a natural bodily function that most take for granted. But for people with chronic obstructive pulmonary disease, or COPD, inhaling and exhaling is a daily struggle. In this podcast, Dr. Anne Wheaton discusses health problems associated with COPD.  Created: 3/26/2015 by MMWR.   Date Released: 3/26/2015.

  12. Smart sensor systems for human health breath monitoring applications.

    Science.gov (United States)

    Hunter, G W; Xu, J C; Biaggi-Labiosa, A M; Laskowski, D; Dutta, P K; Mondal, S P; Ward, B J; Makel, D B; Liu, C C; Chang, C W; Dweik, R A

    2011-09-01

    Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced capabilities and minimal size, weight and power consumption. This paper discusses the microsensor/smart sensor system approach and provides a summary of efforts to migrate this technology into human health breath monitoring applications. First, the basic capability of this approach to measure exhaled breath associated with exercise physiology is demonstrated. Building from this foundation, the development of a system for a portable asthma home health care system is described. A solid-state nitric oxide (NO) sensor for asthma monitoring has been identified, and efforts are underway to miniaturize this NO sensor technology and integrate it into a smart sensor system. It is concluded that base platform microsensor technology combined with smart sensor systems can address the needs of a range of breath monitoring applications and enable new capabilities for healthcare.

  13. Low Back Pain? Relax, Breathe and Try Yoga

    Science.gov (United States)

    ... Videos & Tools Español You Are Here: Home → Latest Health News → Article URL of this page: https://medlineplus.gov/news/fullstory_163537.html Low Back Pain? Relax, Breathe and Try Yoga Review of 12 studies found small improvements in ...

  14. Functional morphology and evolution of aspiration breathing in tetrapods.

    Science.gov (United States)

    Brainerd, Elizabeth L; Owerkowicz, Tomasz

    2006-11-01

    In the evolution of aspiration breathing, the responsibility for lung ventilation gradually shifted from the hyobranchial to the axial musculoskeletal system, with axial muscles taking over exhalation first, at the base of Tetrapoda, and then inhalation as well at the base of Amniota. This shift from hyobranchial to axial breathing freed the tongue and head to adapt to more diverse feeding styles, but generated a mechanical conflict between costal ventilation and high-speed locomotion. Some "lizards" (non-serpentine squamates) have been shown to circumvent this speed-dependent axial constraint with accessory gular pumping during locomotion, and here we present a new survey of gular pumping behavior in the tuatara and 40 lizard species. We observed gular pumping behavior in 32 of the 40 lizards and in the tuatara, indicating that the ability to inflate the lungs by gular pumping is a shared-derived character for Lepidosauria. Gular pump breathing in lepidosaurs may be homologous with buccal pumping in amphibians, but non-ventilatory buccal oscillation and gular flutter have persisted throughout amniote evolution and gular pumping may have evolved independently by modification of buccal oscillation. In addition to gular pumping in some lizards, three other innovations have evolved repeatedly in the major amniote clades to circumvent the speed-dependent axial constraint: accessory inspiratory muscles (mammals, crocodylians and turtles), changing locomotor posture (mammals and birds) and respiratory-locomotor phase coupling to reduce the mechanical conflict between aspiration breathing and locomotion (mammals and birds).

  15. Take a Deep Breath (A Minute of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    2016-11-24

    Nearly 16 million Americans have been diagnosed with COPD; however, many may not be aware they have the condition. This podcast discusses the importance of seeing a health care provider if you have trouble breathing.  Created: 11/24/2016 by MMWR.   Date Released: 11/24/2016.

  16. Morbidity prior to a diagnosis of sleep-disordered breathing

    DEFF Research Database (Denmark)

    Jennum, Poul; Ibsen, Rikke Falkner; Kjellberg, Jakob

    2013-01-01

    Sleep-disordered breathing (SDB) causes burden to the sufferer, the healthcare system, and society. Most studies have focused on cardiovascular diseases (CVDs) after a diagnosis of obstructive sleep apnea (OSA) or obesity hypoventilation syndrome (OHS); however, the overall morbidity prior...

  17. Medical diagnostics by laser-based analysis of exhaled breath

    Science.gov (United States)

    Giubileo, Gianfranco

    2002-08-01

    IMany trace gases can be found in the exhaled breath, some of them giving the possibility of a non invasive diagnosis of related diseases or allowing the monitoring of the disease in the course of its therapy. In the present lecture the principle of medical diagnosis based on the breath analysis will be introduced and the detection of trace gases in exhaled breath by high- resolution molecular spectroscopy in the IR spectral region will be discussed. A number of substrates and the optical systems for their laser detection will be reported. The following laser based experimental systems has been realised in the Molecular Spectroscopy Laboratory in ENEA in Frascati for the analysis of specific substances in the exhaled breath. A tuneable diode laser absorption spectroscopy (TDLAS) appartus for the measurement of 13C/12C isotopic ratio in carbon dioxide, a TDLAS apparatus for the detection of CH4 and a CO2 laser based photoacoustic system to detect trace ethylene at atmospheric pressure. The experimental set-up for each one of the a.m. optical systems will be shown and the related medical applications will be illustrated. The concluding remarks will be focuses on chemical species that are of major interest for medical people today and their diagnostic ability.

  18. The effects of aquatic hypercapnia on air-breathing fishes

    DEFF Research Database (Denmark)

    Jew, Corey James; Thomsen, Mikkel; Hicks, James W

    that bimodal breathers inhabit have been reported to be hypercapnic as well. Using a biomodal respirometer, data from three air-breathing fishes show that when in hypercapnic water, excretion of CO2 into the air signicantly increases and can account for 10% to 70% of metabolically produced CO2 depending...

  19. Nasal and Oral Inspiration during Natural Speech Breathing

    Science.gov (United States)

    Lester, Rosemary A.; Hoit, Jeannette D.

    2014-01-01

    Purpose: The purpose of this study was to determine the typical pattern for inspiration during speech breathing in healthy adults, as well as the factors that might influence it. Method: Ten healthy adults, 18-45 years of age, performed a variety of speaking tasks while nasal ram pressure, audio, and video recordings were obtained. Inspirations…

  20. Speech Breathing in Speakers Who Use an Electrolarynx

    Science.gov (United States)

    Bohnenkamp, Todd A.; Stowell, Talena; Hesse, Joy; Wright, Simon

    2010-01-01

    Speakers who use an electrolarynx following a total laryngectomy no longer require pulmonary support for speech. Subsequently, chest wall movements may be affected; however, chest wall movements in these speakers are not well defined. The purpose of this investigation was to evaluate speech breathing in speakers who use an electrolarynx during…

  1. CFD Simulations of Contaminant Transport between two Breathing Persons

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter V.

    Experiments have shown that exhalation from one person is able to penetrate the breathing zone of another person at a distance. Computational Fluid Dynamics (CFD) is used to investigate the dependency of the personal exposure on some physical parameters, namely: Pulmonary ventilation rate...

  2. Modeling of the expiratory flow pattern of spontaneously breathing cats

    NARCIS (Netherlands)

    Walraven, D; van der Grinten, CPM; Bogaard, JM; van der Ent, CK; Luijendijk, SCM

    2003-01-01

    A mathematical model was developed describing the entire expiratory flow pattern during spontaneous, tidal breathing in the absence of expiratory muscle activity. It provides estimates for the time constants of the respiratory System (tauRS(model)) and of the decay of continuing inspiratory muscle a

  3. Lung Motion Model Validation Experiments, Free-Breathing Tissue Densitometry, and Ventilation Mapping using Fast Helical CT Imaging

    Science.gov (United States)

    Dou, Hsiang-Tai

    geometries, employed as ground truth data. Image similarity between the simulated and ground truth scans was evaluated. The model validation experiments were conducted in a patient cohort of seventeen patients to assess the model robustness and inter-patient variation. The model error averaged over multiple tracked positions from several breathing cycles was found to be on the order of one millimeter. In modeling the density change under free breathing condition, the determinant of Jacobian matrix from the registration-derived deformation vector field yielded volume change information of the lung tissues. Correlation of the Jacobian values to the corresponding voxel Housfield units (HU) reveals that the density variation for the majority of lung tissues can be very well described by mass conservation relationship. Different tissue types were identified and separately modeled. Large trials of validation experiments were performed. The averaged deviation between the modeled and the reference lung density was 30 HU, which was estimated to be the background CT noise level. In characterizing the lung ventilation function, a novel method was developed to determine the extent of lung tissue volume change. Information on volume change was derived from the deformable image registration of the fast helical CT images in terms of Jacobian values with respect to a reference image. Assuming the multiple volume change measurements are independently and identically distributed, statistical formulation was derived to model ventilation distribution of each lung voxels and empirical minimum and maximum probability distribution of the Jacobian values was computed. Ventilation characteristic was evaluated as the difference of the expectation value from these extremal distributions. The resulting ventilation map was compared with an independently obtained ventilation image derived directly from the lung intensities and good correlation was found using statistical test. In addition, dynamic

  4. Effects of Breathing Resistance on Resting Ventilatory Sensitivity to CO2

    Science.gov (United States)

    2014-08-12

    BREATHING RESISTANCE ON RESTING VENTILATORY SENSITIVITY TO CO2 Authors: B. Shykoff, Ph.D...June 2013 - Feb 2014 4. TITLE AND SUBTITLE (U) EFFECTS OF BREATHING RESISTANCE ON RESTING VENTILATORY SENSITIVITY TO CO2 5a...the respiratory muscles by optimizing for their loading, ventilatory response to CO2 may be damped when resistance to breathing increases. This has

  5. An off-line breath sampling and analysis method suitable for large screening studies

    NARCIS (Netherlands)

    Steeghs, M.M.L.; Cristescu, S.M.; Munnik, P.; Zanen, P.; Harren, F.J.M.

    2007-01-01

    We present a new, off-line breath collection and analysis method, suitable for large screening studies. The breath collection system is based on the guidelines of the American Thoracic Society for the sampling of exhaled NO. Breath containing volatile gases is collected in custom-made black-layered

  6. Dysfunctional breathing in children with asthma : a rare but relevant comorbidity

    NARCIS (Netherlands)

    de Groot, Eric P.; Duiverman, Eric J.; Brand, Paul L. P.

    2013-01-01

    Hyperventilation and other clinical manifestations of dysfunctional breathing have been reported in childhood, but the prevalence is unknown. In adults, dysfunctional breathing may be a relevant comorbidity in asthma. We aimed to determine the prevalence of dysfunctional breathing in children with a

  7. Quantitative Analysis of Periodic Breathing and Very Long Apnea in Preterm Infants

    Science.gov (United States)

    Mohr, Mary A.

    Electronic signals from bedside monitors in University of Virginia's Neonatal Intensive Care Unit (NICU) are routinely collected and stored. The overall goal of our research is predictive monitoring: we seek patterns in signals that give early warning of impending pathology. This work focuses on apnea (pauses in regular respiration), and on periodic breathing (regular cycles of breathing and apnea). Our examination of apnea events revealed a disturbing number of cases in which the cessation of breathing lasted at least 60 seconds. These observations were validated, clinical correlations of these events were identified, and a theory was developed that partially explains how they occur. Periodic breathing in neonates is a normal developmental phenomenon. It arises when there is instability in the respiratory control system. A mathematical model of periodic breathing was developed to analyze the stability of the control system in infants. Periodic breathing has long been thought to be benign, however, exaggerated durations of periodic breathing may be an indicator of pathology. Characterization of periodic breathing has previously been limited to short monitoring times in small numbers of infants. An automated system for measurement and characterization of periodic breathing was developed and applied to 5 years of data from the NICU. The amount of periodic breathing that infants had was found to increase with gestational age (up to 32 weeks). Also, times of excessive periodic breathing were recorded and clinical correlations were sought. A significant increase in periodic breathing in the 24 hours before diagnosis of necrotizing enterocolitis was found.

  8. 78 FR 25475 - Certain Sleep-Disordered Breathing Treatment Systems and Components Thereof: Institution of...

    Science.gov (United States)

    2013-05-01

    ... COMMISSION Certain Sleep-Disordered Breathing Treatment Systems and Components Thereof: Institution of... importation, and the sale within the United States after importation of certain sleep-disordered breathing... after importation of certain sleep- disordered breathing treatment systems and components thereof...

  9. A Study on How to Breathe Properly When Practicing Tai Chi Chuan

    Science.gov (United States)

    Yang, Hanchun

    2011-01-01

    When practicing Tai Chi Chuan, proper breath plays an important role in shaping Tai Chi Chuan's style and its fitness value. The paper aims to analyse the postures of Tai Chi Chuan and its breath characteristics. The paper also presents some new insights on how to co-ordinate breath with postures by case studies.

  10. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for use as protection against gas leaking from a refrigeration unit. (b) The self-contained...

  11. Exhaled nitric oxide in healthy young children during tidal breathing through a facemask

    DEFF Research Database (Denmark)

    Daniel, Peter F; Klug, Bent; Valerius, Niels H

    2007-01-01

    The aim of this study was to establish reference values and to examine day-to-day and within-day variations of exhaled nitric oxide (eNO) during tidal breathing in healthy children using a newly described method. Exhaled NO was measured on-line and off-line during tidal breathing through a facemask...... tidal breathing in young children....

  12. Progress in SIFT-MS: breath analysis and other applications.

    Science.gov (United States)

    Spaněl, Patrik; Smith, David

    2011-01-01

    The development of selected ion flow tube mass spectrometry, SIFT-MS, is described from its inception as the modified very large SIFT instruments used to demonstrate the feasibility of SIFT-MS as an analytical technique, towards the smaller but bulky transportable instruments and finally to the current smallest Profile 3 instruments that have been located in various places, including hospitals and schools to obtain on-line breath analyses. The essential physics and engineering principles are discussed, which must be appreciated to design and construct a SIFT-MS instrument. The versatility and sensitivity of the Profile 3 instrument is illustrated by typical mass spectra obtained using the three precursor ions H(3)O(+), NO(+) and O(2)(+)·, and the need to account for differential ionic diffusion and mass discrimination in the analytical algorithms is emphasized to obtain accurate trace gas analyses. The performance of the Profile 3 instrument is illustrated by the results of several pilot studies, including (i) on-line real time quantification of several breath metabolites for cohorts of healthy adults and children, which have provided representative concentration/population distributions, and the comparative analyses of breath exhaled via the mouth and nose that identify systemic and orally-generated compounds, (ii) the enhancement of breath metabolites by drug ingestion, (iii) the identification of HCN as a marker of Pseudomonas colonization of the airways and (iv) emission of volatile compounds from urine, especially ketone bodies, and from skin. Some very recent developments are discussed, including the quantification of carbon dioxide in breath and the combination of SIFT-MS with GC and ATD, and their significance. Finally, prospects for future SIFT-MS developments are alluded to.

  13. The physiology and pathophysiology of human breath-hold diving.

    Science.gov (United States)

    Lindholm, Peter; Lundgren, Claes E G

    2009-01-01

    This is a brief overview of physiological reactions, limitations, and pathophysiological mechanisms associated with human breath-hold diving. Breath-hold duration and ability to withstand compression at depth are the two main challenges that have been overcome to an amazing degree as evidenced by the current world records in breath-hold duration at 10:12 min and depth of 214 m. The quest for even further performance enhancements continues among competitive breath-hold divers, even if absolute physiological limits are being approached as indicated by findings of pulmonary edema and alveolar hemorrhage postdive. However, a remarkable, and so far poorly understood, variation in individual disposition for such problems exists. Mortality connected with breath-hold diving is primarily concentrated to less well-trained recreational divers and competitive spearfishermen who fall victim to hypoxia. Particularly vulnerable are probably also individuals with preexisting cardiac problems and possibly, essentially healthy divers who may have suffered severe alternobaric vertigo as a complication to inadequate pressure equilibration of the middle ears. The specific topics discussed include the diving response and its expression by the cardiovascular system, which exhibits hypertension, bradycardia, oxygen conservation, arrhythmias, and contraction of the spleen. The respiratory system is challenged by compression of the lungs with barotrauma of descent, intrapulmonary hemorrhage, edema, and the effects of glossopharyngeal insufflation and exsufflation. Various mechanisms associated with hypoxia and loss of consciousness are discussed, including hyperventilation, ascent blackout, fasting, and excessive postexercise O(2) consumption. The potential for high nitrogen pressure in the lungs to cause decompression sickness and N(2) narcosis is also illuminated.

  14. An automated system for pulmonary function testing

    Science.gov (United States)

    Mauldin, D. G.

    1974-01-01

    An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.

  15. Design and evaluation of an exhaled breath sampler for biological monitoring of organic solvents.

    Science.gov (United States)

    Periago, J F; Luna, A; Morente, A; Zambudio, A

    1992-04-01

    We designed a breath sampler based on a tube which collects the final portion of exhaled air. The passage of successive fractions through a layer of activated charcoal is controlled by a three-way valve. This system was validated in a controlled atmosphere of n-hexane and toluene at four concentrations between 12 and 110 mg m-3 and 12 and 115 mg m-3, respectively. Uptake volumes of 0.1, 0.2 and 0.31 were tested at relative humidities of 46% and 98%. There were no significant differences in the recoveries obtained under any of the conditions tested. We confirmed the reproducibility between successive samples in volunteers and exposed workers, and found no significant differences between the different sampling conditions studied. Our system enriches the sample in an adsorbent cartridge by collecting successive fractions of end-exhaled breath from one or more exhalations until the amount required by the analytical method has been accumulated. It is portable, economical and highly operative in the field.

  16. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    Science.gov (United States)

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; di Natale, Corrado; D'Amico, Arnaldo

    2015-11-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.

  17. The use of a portable breath analysis device in monitoring type 1 diabetes patients in a hypoglycaemic clamp: validation with SIFT-MS data.

    Science.gov (United States)

    Walton, C; Patel, M; Pitts, D; Knight, P; Hoashi, S; Evans, M; Turner, C

    2014-09-01

    Monitoring blood glucose concentrations is a necessary but tedious task for people suffering from diabetes. It has been noted that breath in people suffering with diabetes has a different odour and thus it may be possible to use breath analysis to monitor the blood glucose concentration. Here, we evaluate the analysis of breath using a portable device containing a single mixed metal oxide sensor during hypoglycaemic glucose clamps and compare that with the use of SIFT-MS described in previously published work on the same set of patients. Outputs from both devices have been correlated with the concentration of blood glucose in eight volunteers suffering from type 1 diabetes mellitus. The results demonstrate that acetone as measured by SIFT-MS and the sensor output from the breath sensing device both correlate linearly with blood glucose; however, the sensor response and acetone concentrations differ greatly between patients with the same blood glucose. It is therefore unlikely that breath analysis can entirely replace blood glucose testing.

  18. 13C呼气法研究膳食纤维对健康受试者碳水化合物代谢的影响%Effect of dietary fiber on carbohydrate metabolism in healthy volunteers with 13C breath test

    Institute of Scientific and Technical Information of China (English)

    李宁; 江骥; 胡蓓; 于康

    2011-01-01

    Objective To investigate the effect of dietary fiber on carbohydrate metabolism of healthy volunteers after the intake of corn starch meal. Methods Totally 12 healthy volunteers aged (25. 8 ± 5. 3) years were enrolled in this study, and they were equally randomly divided into two groups (group A and group B). This was an open, randomized, cross-over, and two-period study, and each period lasted for one day. In period 1, the subjects in group A received fiber-free corn starch and group B received high-fiber corn starch (containing 16 g dietary fiber). In period 2, the two groups are crossed. There was a one-week wash-out time between the two study days. On the study day, breath samples of fasting and 0. 5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0, 6.0,7. 0, 8. 0 hours post meal were collected to measure13 CO2. Results The delta over baseline at 0. 5, 1.5, 2. 0,2. 5, 3. 0, 4. 0 hour after test meal in fiber free group and in high fiber group were 0. 79, 2. 03, 2. 57, 2. 86,3. 02, 3. 18 and 0. 16, 1. 33, 1.77, 2. 10, 2. 34, 2.42, respectively (the P value was 0. 014, 0. 014, 0. 011,0.018, 0. 036, and 0.020, respectively). Peak concentration of delta over baseline of fiber free group and high fiber group was 3.18 and 2. 56 respectively, there was no significant difference between two groups (P > 0. 05) ,peak time of the group at 4. 0 hour and 3. 5 hour respectively, showed significant difference (P = 0. 032). The cumulative percentage dose recovered 0. 5-6. 0 hours after test meal in fiber-free group and in high-fiber group were 0.41, 1.46, 3.15, 5.50, 8.28, 11.30, 14.42, 17. 62, 23. 65, 28. 78 and 0. 09, 0. 55, 1.61, 3.22,5.23,7.53, 10.09, 12.68, 17.60, 22.27 respectively (the P value was 0.014, 0.018, 0.018, 0.014, 0.013,0.014, 0.018, 0.020, 0.025, and 0.044, respectively). However, there was no significant difference 6.0 hours after meal (P > 0. 05 ). Conclusion The dietary fiber used in this study can delay the absorption of carbohydrate 6. 0 hours within intake

  19. Exhaled breath malondialdehyde, spirometric results and dust exposure assessment in ceramics production workers

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Zare Sakhvidi

    2015-02-01

    Full Text Available Introduction The study aimed at measuring exhaled breath malondialdehyde (EBC-MDA in workers exposed to dust containing silica and at its comparison with the non-exposed control group. Material and methods The cross sectional, case-control study (N = 50 was performed in a tile and ceramics production factory in Yazd, Iran. EBC-MDA was quantified in exhaled breath of the participants by a lab made breath sampler. Exposure intensity was measured according to the NIOSH 0600 method in selected homogeneous exposure groups. Additionally, spirometry test was conducted to investigate a correlation between EBC-MDA and spirometric findings in the exposed workers. Results There was no difference in the observed exposure intensities of silica containing dust in different units. However, “coating preparation” was the unit with the highest concentration of dust. Although, the level of EBC-MDA in the cases was slightly higher than in the controls, the difference was not statistically significant (U = 252, p = 0.464. A significant and positive correlation was found between dust exposure intensity in working units and the measured EBC-MDA of workers (r = 0.467, N = 25, p = 0.027. There were also no statistically significant differences among job categories in the exposed group for the values of FEV1% (F(3, 44 = 0.656, p = 0.584, FVC% (F(3, 44 = 1.417, p = 0.172, and FEV1/FVC% (F(3, 44 = 1.929, p = 0.139. Conclusions The results showed a significant correlation between respirable dust exposure intensity and the level of EBC-MDA of the exposed subjects. However, our results did not show a significant correlation between lung function decreases and EBC-MDA.

  20. Association of Some Environmental Factors with Breath Carbon Monoxide Levels of Some Taxi Drivers in Ankara

    Directory of Open Access Journals (Sweden)

    Oguz Baran

    2010-12-01

    Full Text Available AIM: Taxi drivers are among the occupational groups with the highest smoking prevalence and exposure to carbon monoxide (CO. This study aimed to measure breath CO levels of some taxi drivers working in Ankara and to find out some associated factors (if any. METHOD: The descriptive study was carried out with 173 taxi drivers from 14 different taxi stations in the center of Ankara. Data was collected by face to face interviews with a standart questionnaire, while breath CO was measured by a Pi-CO Smokerlyser. Descriptive statistics were used to summarize data, whereas chi-square, independant samples t-test and One-Way ANOVA were used to compare groups by SPSS 15.0 statistical package programme. RESULTS: In the study, all of the taxi drivers (n=173 were male with a mean age of 39.2±9.6 years. Of the drivers, 58.4% were current smokers, whereas 75.1% were exposed to enviromental tobacco smoke. The frequency of indoor smoking in the taxi stations, taxis and drivers’ homes were 48.0%, 45.1%, and 59.0%, respectively. The mean breath CO level of the drivers was 16.9±12.8 ppm. CO level was positively associated with the current smoking status, total years of smoking, number of cigarettes smoked per day and passive exposure to tobacco smoke, whereas the association was negative with the elapsed time from the last cigarette smoked (p0.05. CONCLUSION: Results of the study provide evidence in support of the previous literature that smoking is one of the most important sources of carbonmonoxide. Interventions such as awareness raising trainings, referral of smokers willing to quit smoking to smoking cessation centers and screening programmes for smoking related diseases are needed to be implemented in collaboration with the relevant drivers’ associations. [TAF Prev Med Bull 2010; 9(6.000: 591-596